ARCH-02 round 2: the pin could not tell one red leg from two, and the tool went
quiet when a flag was forgotten

Both blocking findings were reproduced before anything was changed, and both are
the class this card exists to guard against.

B1. THE PIN WAS A COUNT, AND A COUNT CANNOT SEPARATE TWO ROUTES. The rehearsal
reaches the disarmed latch by two independent paths and prints every finding
TWICE per red leg - once in the leg's block, once in the closing summary - so
ONE red leg satisfied `count(...) >= 2`. Measured: shipped code 4; with
`migrate_unit_keys()` handed the roster's own name (SAME-STEP fixed) 2, PASSES;
with a guard-side fix (both fixed) 0. The check named "NOT THE SAME-STEP PATH
ALONE" reported ok on the build whose only remaining failure IS the staged path.
The tool now prints `LEG <id>` / `END LEG <id>` and the pin requires the finding
in EACH leg by name.

⚠️ AND THE FIRST SPLITTER CARRIED THE SAME DEFECT ONE LEVEL DOWN - it opened on
the marker and never closed, so the last leg absorbed the closing summary and
read red whenever ANY leg was red. Caught by building the one fixture that
separates them. Part 5b is now that fixture, run every time: a tree in which
SAME-STEP is genuinely clean and STAGED is not. A per-thing check that has never
seen the things disagree is a total with extra steps.

⚠️ AND IT CORRECTS A CLAIM THIS CARD MADE. `main.py:250` is NOT the whole fix.
Measured on that exact change: LEG SAME-STEP clean, LEG STAGED still DISARMED -
the staged path stamps `schema_version` on the flat start and the roster start's
migration returns early before the name it is handed matters. DOCS.md now says
so, with the measurement.

B2. A FORGOTTEN FLAG WAS A CLEAN BILL OF HEALTH. Omitting `--live-entities`
printed "nothing orphaned" and exited 0, with `grep -ci` for the words returning
0 - while an UNREADABLE file exited 2. The asymmetry was backwards. Omitting it
now refuses (exit 2); `--no-live-entities` is the deliberate opt-out and carries
a standing banner in the header AND on the exit line, because a report is
skimmed from the bottom.

N1. THE REFERENCE DID NOT CARRY WHAT HA KEYS ON. It held entity_ids only, so
renaming `mqtt.BASE` (every unique_id moves) and changing `DEVICE["identifiers"]`
(HA sees a new device) both came back exit 0 - real orphanings with every
composed id byte-identical. The reference is now three columns
(`entity_id unique_id device`), is loaded on EVERY run including a degraded one,
and M7/M8 pin both. `object_id` is deliberately not a column and its rename is
required to SURVIVE, which is what bounds the four mqtt.py mutations.

Also found while fixing the above, and fixed with its own paired positive: the
VANISHED check did not carry the default/non-default rule the STRANDED check
does, so a pair of migrated DEFAULTS moving namespace read as two findings and
CONTROL-C went red on a CORRECT build. M9 drops non-default keys and must still
be a finding.

N2/N3. DOCS.md withdraws the unmeasured "not recoverable by advancing again" -
its own reasoning cut the other way and nothing here tested a re-advance; the
measured part (eight rows stop updating, history gaps, automations stop firing)
stands. And the byte-identical-input property is `test_rehearse.py`'s assertion,
not the tool's.

FRAMING. SAFETY-44 is ALREADY RECORDED on the merge base - `test_maintenance.py`
section 13, with the "guard is defeated by the very key the defect wrote"
sentence, in a file this card does not touch. DOCS.md now says this is
independent re-confirmation through a second instrument, reachable from an
owner-supplied state file rather than only from a fixture, and not a discovery.

app/ is still untouched. 59 checks in test_rehearse.py, 9 mutations red, 2
required survivors, 3 clean controls.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-08 14:21:34 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI — routes only, status and configuration
    config_page.py         the configuration page's markup, style and script
    configui.py            its field model, built from the Supervisor's own
                           schema + translations — owns no key, label or rule
    selfconfig.py          reading and writing this add-on's own options,
                           with the validate-first / compare-and-swap gate
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
  tools/supervisor_selfapi_probe.py  what the Supervisor really permits and
                           returns, run against its own release image
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.
S
Description
No description provided
Readme
27 MiB
Languages
Python 98%
JavaScript 1.3%
CSS 0.3%
Shell 0.2%