glenn schrooyenandClaude Opus 5 59ab73559e SAFETY-32 round 3: a fixture of N packs cannot separate reductions that agree on N
Both blockers were the recurring defect sitting inside the fix written to close
it: a check whose TEXT claims more than its FIXTURE can observe. Both survived a
green 19-file suite on 8501e05.

  max(floors) -> max(floors[-2:])   +5 bytes.  12c2's only counterfactual raised
  the LAST pack, and every window ending at the roster's end follows the last
  pack. The check said "the reduction reads every entry"; the data reached "it
  reads the last entry".

  self.packs -> self.packs[:2]      +4 bytes.  All three 12g runs drove a TWO-pack
  roster, where [:2] IS the roster. The check said "what is reduced is the ROSTER
  and not a POSITION in it"; the true claim was the narrower "no SINGLE-POSITION
  slice passes all three runs".

The prose is cut back to what the old data reaches, and new data added for the
rest. No app/ file is touched - app/peakguard.py and app/main.py are byte-identical
to 8501e05.

12c2 - the pure function:
  * a ROSTER SET: the same four simulated cut-outs with the deepest moved to each
    of the four positions.
  * a computed FAMILY TABLE of fourteen rewrites, printed, with the roster that
    kills each. A member with an empty kill list takes the check RED naming it.
  * a LENGTH SWEEP: 78 rosters, lengths 1-12, deepest at every position of each.
    Closes every head window max(floors[:w]) and tail window max(floors[-w:]) of
    width 1-11 in one property.

12g - the call site:
  * _floor_reaching_decide() takes *floors; extra units join through the same
    second_inverter() hook.
  * THREE-pack runs with the deep cut-out at index 0, 1 and 2. Every positional
    slice of a three-pack roster drops a position, and the run whose deep pack
    sits there answers the option where the roster answers the cut-out.
  * a POSITIONAL-SLICE TABLE computed against the REAL Controller.packs each of
    the six cycles ran and the REAL PeakDecision.soc_floor it produced.
  * an EXACT STRUCTURAL PIN on the roster argument's identity. Not the substring
    test round 2 removed: "self.packs" in expr is TRUE of every slice;
    ast.unparse(arg) == "self.packs" is FALSE of all of them.

THE GENERAL LAW, and why the pin is there: a fixture of N packs cannot separate
two reductions that agree on N packs, and the regress does not terminate in a
fixture. [:1] needed two packs, [:2] three, [:3] four. This round's own battery
found self.packs[:3] (+4) and self.packs[-3:] (+5) surviving all six behavioural
runs; the structural pin is what closes them, and one more pack would only have
moved the hole.

Battery: 46 mutations over the reduction, the call site, Controller.packs and
pack_floor_pct()'s conjunction. Bytecode purged and counted 23 -> 0 for each.
43 red, 3 survivors, all three recorded:
  max(floors[:12]) / max(floors[-12:])  NOT CAUGHT - needs a 13-pack roster,
                                        reported with its size, row 27.
  max(set(floors))                      EQUIVALENT - max is duplicate-invariant.
(list(reversed(self.packs)) is equivalent too and is red on the structural pin.)

In-process mutation rows 24-27 record all of it, including the not-caught one.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-04 21:42:07 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.