FCST-03 shipped `fill_from_yesterday()` complete and checked, and shipped the consumers written for it - `TariffPlan.firm_points()`, `cheap_now()`'s refusal of a provisional hour, and `arbitrage()`'s refusal 3, which drops provisional hours from the trade set rather than refusing the whole series. It shipped NO CALLER. Nothing in `app/` named the fill, so no series ever contained a carried point and every one of those consumers was exercising its all-firm branch. ⚠️ THE DEFECT THAT PRODUCED WAS NOT AN ERROR ANYWHERE. `load_prices()` returns what the feed published and nothing widened it to the requested horizon, so on a dynamic site between midnight and the 14-16 h CET publication the plan covered the rest of today and nothing more - measured on the fixture here, 24 h against a 48 h request. `arbitrage()` then took `max - min` over that truncated window and reported a spread. The number was real, the window was half the one configured, and nothing said so: tomorrow evening's peak, the hour a morning charge would be sold into, was not in the series to be compared against anything. A missing hour is not a wrong price - it is an hour the optimiser never learns exists. WHAT THIS ADDS. `app/price_history.py` keeps the PUBLISHED prices of the last KEEP_DAYS Brussels days in /data/price_history.json; `resolve_tariff()` gains a required keyword-only `history` and fills every unpublished hour of the horizon from yesterday's same-wall-clock hour, flagged. Persistence rather than a variable on the refresh task, because the window the fill exists for is midnight -> publication and an add-on restarted at 08:00 would otherwise spend all of it on the truncated series. Not in state.json: the refresh runs every 1800 s and that file holds the maintenance history and SAFETY-02's latch. ⚠️ ONE CHANGE HERE MOVES ENERGY, AND IT IS NOT THE ONE THE CARD IS NAMED FOR. Carried hours are provisional, so §8.3 keeps them out of the trade set: the fill widens what the optimiser can SEE, never what it may DO, and test_price_history.py checks that so it cannot be overclaimed later. What does change a trade is that the filled series is windowed to [since, until), so hours that have ALREADY ELAPSED are no longer in the spread. Before, a cheap night that had gone sat in the series as the day's cheapest hour - and a cycle cannot buy in an hour that is past, so the trade was quietly never taken. Section 2 grades this by finding the cheapest firm hour with and without the fill and showing it MOVES, from 02:00 UTC to 08:00 UTC on the fixture. ⚠️ A DEAD FEED IS STILL §11.4, NOT YESTERDAY. The fill runs only on a `series` read. The two are indistinguishable to the optimiser - both 100 % provisional, so arbitrage refuses on the firm-pair rung and `cheap_now()` is False - so preferring yesterday's feed over the `static_profile` an operator configured FOR that case would change a documented degradation for a difference only the status page can see. That, and two more, in DECISIONS/FCST-04-the-day-that-is-carried.md. ⚠️ THE ANTI-DECAY RULE IS AN ORDERING, NOT A VALIDATION, and saying so is more useful than a guarantee that would not hold. Feeding the filled series back in is how this rots - day 2 carries day 1's guesses, day 3 carries day 2's carry of them, behind a `provisional` flag that stays TRUE while the NUMBER decays. No value-level check can catch it: a carried point and `eneco_eddy`'s published-provisional quarter are the same three fields with the same flag. So `carry()` is the only public entry, it records BEFORE it fills, the filled series exists only as a return value the object never sees again, and test_price_history.py walks app/ for any other module naming `_remember` and reads `carry()`'s AST to pin the order. EVIDENCE. 29/29 test files pass in the CI image. Eight mutations driven against app/price_history.py and app/static_tariff.py, __pycache__ purged before each run per MUTATION.md/TEST-15: newest-record lookup (5 red), recording the filled series (1), replace-instead-of-merge (10), UTC-date keying (10), removing the fill call entirely (12), a lost price field defaulting to 0.0 (2), prune by clock arithmetic (1), a degraded reason that stops naming its cause (1). No survivors; baseline and revert both green. Three of those first crashed the harness instead of reporting a FAIL - "it was refused" and "it broke on the way to being refused" must not grade the same - so `why()` and `_priced()` were added and the run repeated. No option added, config.yaml untouched, and the CHANGELOG entry deliberately picks no version: PKG-07's rule, and only the deployer knows whether 0.9.0's image has been pulled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
GoodWe RS485 Controller — Home Assistant add-on repository
Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.
repository.yaml add-on repository metadata
goodwe_controller/ the add-on
config.yaml manifest + options schema (the per-site config form)
app/ the controller
control.py the control law — pure functions, no I/O
maintenance.py the monthly cycle state machine
hass.py Supervisor/Core API access
store.py persistent state in /data
mqtt.py optional status entities
web.py ingress UI — routes only, status and configuration
config_page.py the configuration page's markup, style and script
configui.py its field model, built from the Supervisor's own
schema + translations — owns no key, label or rule
selfconfig.py reading and writing this add-on's own options,
with the validate-first / compare-and-swap gate
main.py orchestration, heartbeat, failsafe behaviour
test_control.py runnable checks — no framework needed
test_maintenance.py runnable checks — walks a full cycle in fake time
DOCS.md the add-on's documentation tab
MUTATION.md how to run a mutation so the result means something
tools/mutation_run.sh the mutation harness - purges bytecode, then grades
tools/supervisor_selfapi_probe.py what the Supervisor really permits and
returns, run against its own release image
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
estop/rs485_log.py optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4)
docs/build_guide.py its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md how to edit and rebuild the guide
Picking this up after a break? Read HANDOVER.md first — current state,
what is known broken, and what to do next.
Install
Settings → Add-ons → Add-on store → ⋮ → Repositories → add
https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon
then install GoodWe RS485 Controller.
⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it
anonymously; against a private repo the store shows nothing and gives no useful
error. If it must stay private, install locally instead: copy
goodwe_controller/ into the machine's /addons/ folder, then
ha store reload — it appears as a Local add-on.
⚠️ Bump version: in goodwe_controller/config.yaml for every change.
Supervisor keys the built image by that version, so without a bump it silently
reuses the old image and your fix appears not to work — on your bench and on
every client's machine.
Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.
Read this first
The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.
Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:
- ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
- Wind-down before firmware updates — 0 W written before the update starts.
- RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.
Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md
§10 signed.
Development
The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:
cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py
Both must pass before shipping any change. To prove a check bites - the way
almost every claim in this repository was established - mutate the module and
run tools/mutation_run.sh, which clears __pycache__ first. It is not
optional: a same-size edit reverted inside one second leaves CPython reusing the
old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md
has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre —
each assertion corresponds to a rule whose absence produced an observed failure
on real hardware, and the comments in control.py say which.
Compatibility
Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:
| tag | platform | verdict |
|---|---|---|
ESU EMU ESA BPS BPU EMJ IJL |
105 — ES/EM/BP, AA55-era meter bus | supported |
SPB SPN |
745 — SBP G2 (GW…-SBP-20) |
no |
ESN ESC |
745 — ES G2 (GW…-ES-20) |
no |
ETU EHU BTU … |
205/745/753 — ET/EH/BT hybrids | no |
SDT DST MSU NSU … |
PV-only inverters — no battery to control | no |
A "-20" or "G2" suffix means a different platform with a different meter
protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which
is also what Home Assistant's own integration uses to pick a protocol.
- GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
- The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.