glenn schrooyenandClaude Opus 5 028c3e53fb
checks / unit (pull_request) Successful in 7m13s
Merge release/1.0 (TARIFF-12) into TARIFF-14
Second base move while this card was open: 559f0eb -> a6e64fb. Only
CHANGELOG.md conflicted; test_arbitrage.py auto-merged (TARIFF-12 used
section 8b, this card uses 10, so the two do not collide).

CHANGELOG: both entries under the single ## Unreleased in MERGE ORDER -
TARIFF-12's row and section precede this branch's, because it landed
first. No version number is picked; PKG-06/07's note stands untouched.

WHAT TARIFF-12 CHANGES FOR THIS CARD - written out in decision note §8
rather than left silent, because the question is a fair one.

A served plan can now be up to TARIFF_MAX_AGE_S = 3 * TARIFF_REFRESH_S
= 5400 s old, where before it was at most one refresh interval, and
at() is what answers "what does it cost right now" out of that older
plan.

* PER-POINT SPAN: unaffected, structurally. Every window is derived
  from the neighbours' ABSOLUTE start instants - datetimes in a frozen
  dataclass in a tuple, which cannot move - and _cover_table() runs
  once at construction over data that cannot change. A plan's AGE is a
  property of fetched_at/tariff_at, never of a window. The index cannot
  go stale, which is a small positive under TARIFF-12: a kept plan now
  lives longer and there is nothing in it that needed recomputing.

* ONE-HOUR CAP: unaffected. It bites only at a hole; walking further
  into a series crosses more windows, each resolved on its own
  neighbours.

* THE TAIL: reachable for the first time, and §2's choice survives it.
  At the shipped 48 h horizon the tail is ~46.5 h beyond anything a
  90-minute-stale plan can be asked about. But price_horizon_h is
  int(1,72), so a 1 h horizon is a SUPPORTED configuration, and a
  90-minute serve-stale window against a 1 h series puts `now` past the
  end. Under the chosen rule a quarter-hourly 1 h series ends at :45,
  its window closes on the hour, at() raises Absence, _act() idles and
  §11.4 sends the site to the static profile. Under the REJECTED flat
  one-hour tail the same stale plan would have traded against the :45
  print for up to 45 minutes after the interval it describes had ended.
  So TARIFF-12 does not weaken the decision - it is the first thing
  that makes it reachable, and it selects the same answer. The rule
  should be re-read if TARIFF_MAX_AGE_S is ever widened again.

* TariffPlan.from_feed is a pure predicate on `origin` and TARIFF-12
  keeps or replaces a WHOLE PLAN OBJECT. It never splices two reads
  into one series, so it cannot hand at() an unsorted or duplicated
  point list.

RE-GRADED ON THIS BASE, not carried over: all 29 test files green;
app/price.py byte-identical to the TARIFF-10 merge (90d8ca31f7c0109d,
85953 B) because TARIFF-12 does not touch it; M1 re-driven at +68 B,
red on the same 24 named checks across both files; M3 re-driven at
ZERO BYTES, red on the same 4. Each purged before the run and reverted
with the fingerprint re-checked, from a card-specific harness at
/home/homelab/.cache/t14-mut/ with a mktemp backup inside it.

This branch contributes zero diff to app/main.py and app/static_tariff.py.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 01:47:17 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI — routes only, status and configuration
    config_page.py         the configuration page's markup, style and script
    configui.py            its field model, built from the Supervisor's own
                           schema + translations — owns no key, label or rule
    selfconfig.py          reading and writing this add-on's own options,
                           with the validate-first / compare-and-swap gate
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
  tools/supervisor_selfapi_probe.py  what the Supervisor really permits and
                           returns, run against its own release image
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.
S
Description
No description provided
Readme
20 MiB
Languages
Python 98.2%
JavaScript 1.2%
CSS 0.3%
HTML 0.2%
Shell 0.1%