Second base move while this card was open:559f0eb->a6e64fb. Only CHANGELOG.md conflicted; test_arbitrage.py auto-merged (TARIFF-12 used section 8b, this card uses 10, so the two do not collide). CHANGELOG: both entries under the single ## Unreleased in MERGE ORDER - TARIFF-12's row and section precede this branch's, because it landed first. No version number is picked; PKG-06/07's note stands untouched. WHAT TARIFF-12 CHANGES FOR THIS CARD - written out in decision note §8 rather than left silent, because the question is a fair one. A served plan can now be up to TARIFF_MAX_AGE_S = 3 * TARIFF_REFRESH_S = 5400 s old, where before it was at most one refresh interval, and at() is what answers "what does it cost right now" out of that older plan. * PER-POINT SPAN: unaffected, structurally. Every window is derived from the neighbours' ABSOLUTE start instants - datetimes in a frozen dataclass in a tuple, which cannot move - and _cover_table() runs once at construction over data that cannot change. A plan's AGE is a property of fetched_at/tariff_at, never of a window. The index cannot go stale, which is a small positive under TARIFF-12: a kept plan now lives longer and there is nothing in it that needed recomputing. * ONE-HOUR CAP: unaffected. It bites only at a hole; walking further into a series crosses more windows, each resolved on its own neighbours. * THE TAIL: reachable for the first time, and §2's choice survives it. At the shipped 48 h horizon the tail is ~46.5 h beyond anything a 90-minute-stale plan can be asked about. But price_horizon_h is int(1,72), so a 1 h horizon is a SUPPORTED configuration, and a 90-minute serve-stale window against a 1 h series puts `now` past the end. Under the chosen rule a quarter-hourly 1 h series ends at :45, its window closes on the hour, at() raises Absence, _act() idles and §11.4 sends the site to the static profile. Under the REJECTED flat one-hour tail the same stale plan would have traded against the :45 print for up to 45 minutes after the interval it describes had ended. So TARIFF-12 does not weaken the decision - it is the first thing that makes it reachable, and it selects the same answer. The rule should be re-read if TARIFF_MAX_AGE_S is ever widened again. * TariffPlan.from_feed is a pure predicate on `origin` and TARIFF-12 keeps or replaces a WHOLE PLAN OBJECT. It never splices two reads into one series, so it cannot hand at() an unsorted or duplicated point list. RE-GRADED ON THIS BASE, not carried over: all 29 test files green; app/price.py byte-identical to the TARIFF-10 merge (90d8ca31f7c0109d, 85953 B) because TARIFF-12 does not touch it; M1 re-driven at +68 B, red on the same 24 named checks across both files; M3 re-driven at ZERO BYTES, red on the same 4. Each purged before the run and reverted with the fingerprint re-checked, from a card-specific harness at /home/homelab/.cache/t14-mut/ with a mktemp backup inside it. This branch contributes zero diff to app/main.py and app/static_tariff.py. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
GoodWe RS485 Controller — Home Assistant add-on repository
Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.
repository.yaml add-on repository metadata
goodwe_controller/ the add-on
config.yaml manifest + options schema (the per-site config form)
app/ the controller
control.py the control law — pure functions, no I/O
maintenance.py the monthly cycle state machine
hass.py Supervisor/Core API access
store.py persistent state in /data
mqtt.py optional status entities
web.py ingress UI — routes only, status and configuration
config_page.py the configuration page's markup, style and script
configui.py its field model, built from the Supervisor's own
schema + translations — owns no key, label or rule
selfconfig.py reading and writing this add-on's own options,
with the validate-first / compare-and-swap gate
main.py orchestration, heartbeat, failsafe behaviour
test_control.py runnable checks — no framework needed
test_maintenance.py runnable checks — walks a full cycle in fake time
DOCS.md the add-on's documentation tab
MUTATION.md how to run a mutation so the result means something
tools/mutation_run.sh the mutation harness - purges bytecode, then grades
tools/supervisor_selfapi_probe.py what the Supervisor really permits and
returns, run against its own release image
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
estop/rs485_log.py optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4)
docs/build_guide.py its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md how to edit and rebuild the guide
Picking this up after a break? Read HANDOVER.md first — current state,
what is known broken, and what to do next.
Install
Settings → Add-ons → Add-on store → ⋮ → Repositories → add
https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon
then install GoodWe RS485 Controller.
⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it
anonymously; against a private repo the store shows nothing and gives no useful
error. If it must stay private, install locally instead: copy
goodwe_controller/ into the machine's /addons/ folder, then
ha store reload — it appears as a Local add-on.
⚠️ Bump version: in goodwe_controller/config.yaml for every change.
Supervisor keys the built image by that version, so without a bump it silently
reuses the old image and your fix appears not to work — on your bench and on
every client's machine.
Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.
Read this first
The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.
Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:
- ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
- Wind-down before firmware updates — 0 W written before the update starts.
- RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.
Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md
§10 signed.
Development
The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:
cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py
Both must pass before shipping any change. To prove a check bites - the way
almost every claim in this repository was established - mutate the module and
run tools/mutation_run.sh, which clears __pycache__ first. It is not
optional: a same-size edit reverted inside one second leaves CPython reusing the
old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md
has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre —
each assertion corresponds to a rule whose absence produced an observed failure
on real hardware, and the comments in control.py say which.
Compatibility
Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:
| tag | platform | verdict |
|---|---|---|
ESU EMU ESA BPS BPU EMJ IJL |
105 — ES/EM/BP, AA55-era meter bus | supported |
SPB SPN |
745 — SBP G2 (GW…-SBP-20) |
no |
ESN ESC |
745 — ES G2 (GW…-ES-20) |
no |
ETU EHU BTU … |
205/745/753 — ET/EH/BT hybrids | no |
SDT DST MSU NSU … |
PV-only inverters — no battery to control | no |
A "-20" or "G2" suffix means a different platform with a different meter
protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which
is also what Home Assistant's own integration uses to pick a protocol.
- GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
- The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.