adminandClaude Opus 5 f620f7cf80
checks / unit (pull_request) Successful in 7m12s
TARIFF-07: three plugins that never fetched a price are withdrawn, and a site configured on one is told so
engie_dynamic, totalenergies_dynamic and eneco_eddy are removed from PROVIDERS
and from every surface that listed them. They did not stop working - they never
worked. Re-verified by hand on 2026-09-13 before deleting anything: 404 with
Kong's "no Route matched with those values"; a TLS handshake that fails because
api.totalenergies.be is absent from the certificate's SAN list; 404 with an
empty body. All three are also structurally impossible - the coefficients are
per-contract and behind a customer login, there is no regulator index, and
"Eddy" is not an Eneco product at all.

⚠️ BACKWARD-INCOMPATIBLE. A config legal on the current version is refused on
the next. That is the point of the change: §11.4 turned every failed fetch into
a silent fall back, so a site on one of these ids has been running on
static_profile - or on nothing - since the day it was set, with nothing on its
status page ever differing from a working provider that never found a cheap
hour. validate.py now refuses a retired id with a message naming the id, the
endpoint, what that endpoint answers, which tariff has really been in force,
and what to set instead. No version number is picked here; that depends on a
fact about the live box.

⚠️ config.yaml's price_provider enum deliberately KEEPS all three ids. The
Supervisor validates the options file against that enum before the add-on
starts, so removing them would make an existing config schema-invalid and the
refusal above would never be reached on exactly the sites that need it.
PROVIDERS is two; the enum stays six; test_price.py asserts the schema offers
exactly PROVIDERS | RETIRED_PROVIDERS | {"off"}, derived rather than typed, and
register() refuses to re-register a retired id.

PriceProduct.REALTIME, _WIDE, Uncertainty.REALTIME_PRODUCT and WIDEN_FACTOR's
2.5 are KEPT with no shipped declarer - it is the AC2 seam, and a reviewer
finding a mechanism with zero callers would reasonably delete it. Recorded in
DECISIONS/TARIFF-07-withdrawing-three-plugins.md and pinned by a check.

False claims corrected: every "Belgian imbalance product" claim about
eneco_eddy (DOCS.md, price_forecast.py, price_history.py, static_tariff.py,
FCST-04, CHANGELOG - the two released entries annotated in place rather than
rewritten); the quarter-hourly examples now cite Belgian day-ahead, which
really does settle per quarter since the 15-minute MTU; and
export_price_eur_kwh's "no shipped supplier publishes a dynamic injection
curve", which is false - Eneco publishes 0,1 x BELPEX-H - 1,188 and ENGIE
(B x eSpot_15) - A, same two-coefficient shape with its own coefficients and
its own VAT treatment, so the scalar is a simplification and not the market.

DOCS.md's provider table is two rows and now says honestly what a Belgian
dynamic customer should do today, including that generic_dayahead cannot
express B x spot + A and that price_markup_eur_kwh: float(0,1) could not hold a
negative offset. The formula provider is referenced as planned, not built.

_points_from_json() went with the plugins it served: it read a shape no feed
anybody here has ever reached publishes. The one place it survives is a
negative stimulus, named row_shape_body().

Nine mutations driven, all red; table in the decision record. 29/29 suites
green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 02:46:15 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI — routes only, status and configuration
    config_page.py         the configuration page's markup, style and script
    configui.py            its field model, built from the Supervisor's own
                           schema + translations — owns no key, label or rule
    selfconfig.py          reading and writing this add-on's own options,
                           with the validate-first / compare-and-swap gate
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
  tools/supervisor_selfapi_probe.py  what the Supervisor really permits and
                           returns, run against its own release image
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.
S
Description
No description provided
Readme
26 MiB
Languages
Python 98%
JavaScript 1.3%
CSS 0.3%
Shell 0.2%
HTML 0.2%