glenn schrooyenandClaude Opus 5 e1b9254626
checks / unit (pull_request) Successful in 7m42s
SAFETY-45: a price-driven charge is SIZED by the capacity guard, not switched by it
With arbitrage armed at the shipped defaults, arbitrage and the capacity-tariff
guard drove each other in a sustained limit cycle. Re-measured on TEST-23 stage
3's closed rig against 478ba93, metrics recomputed rather than taken from the
card: `peak_cap_w` 1500 / 1200 W house -> 28 charge onsets an hour, mean period
131.1 s, the grid swinging -455.5 to +3200.0 W; at the SHIPPED
`peak_cap_w: 3500` with an 1800 W house -> 8/h, with a 3000 W house -> 32/h.
The bite rule is `load + max_w > peak_cap_w`, i.e. any house over 1500 W in the
cheapest quarter. §10.2: "an EMS that oscillates is worse than no EMS, both for
hardware wear and - per §9.1 - for the peak it is trying to avoid." And it was
losing the argument it was having: EVERY billed quarter in the three affected
configurations finished OVER the cap.

⚠️ THE CARD'S STATED MECHANISM IS WRONG AND THE CORRECTION IS ON THE RECORD.
The card, and .cache/s45.md before it, say the loop is the quarter boundary
resetting the projection and arbitrage re-arming at full power. It is not. Of
the 27 gaps between the 28 onsets, 23 are 90-120 s (mean 111.5 s) and lie
ENTIRELY INSIDE one quarter; the four long gaps - 230, 240, 250, 255 s - are
exactly the four that SPAN a boundary, so the boundary LENGTHENS the interval
rather than causing an onset. The real cycle, off the recorded fields: the trade
charges at max_w while `wanted = batt_w + excess` is negative and the guard
files NOTHING; `wanted` crosses zero; the guard engages on a floor of 5.3 W;
that flips `arbitrage.guard_state()`, which cancels the WHOLE trade; the
grid-following loop - which targets grid = 0, not grid = ceiling - takes the
actuator and discharges to +1870 W, exporting 420 W; the projection collapses;
the guard releases; the trade re-arms at max_w. A binary interlock keyed on a
continuous quantity. A fix aimed at the boundary would have removed four of
twenty-eight onsets.

THE FIX IS A SHAPE THIS ADD-ON ALREADY HAD. `control.maintenance_charge_floor()`
caps a MAINTENANCE charge at "the headroom left under the site's cap", because
"a maintenance charge is the only thing this system does that is big enough and
long enough to set that peak". ⚠️ That sentence stopped being true when OPT-04
landed. `peakguard.charge_headroom_w()` publishes the same quantity off the
MEASURED guard rather than off the optional `peak_forecast_entity` - the hole
SAFETY-25 had to close in `shaping_suspended()` - and `arbitrage.decide()` sizes
its BUY leg to it, keyword-only and with no default.

NO NEW ARITHMETIC AND NO NEW CONSTANT. The number is `wanted_w` read in the
other direction: `decide()` already computes the DISCHARGE that lands the
quarter on the ceiling, and a negative one is a permitted CHARGE of `-wanted`.
⚠️ `peakguard.decide()` IS UNCHANGED - sha256(decide) = 200090d0835a3a55, 7252 B
on this branch and on 478ba93 - so 2026-08-20's anti-bang-bang rung is exactly
where it was, and tools/replay_ac3.py reproduces 190/190 guarded quarters, 110
engaged cycles, 5 blind and 878 Wh on both trees.

TWO PROPERTIES MAKE IT SAFE TO HAND A STRATEGY, BOTH SWEPT RATHER THAN ARGUED.
It is INVARIANT IN THE BATTERY - raise the charge by dW, the meter rises by dW,
so `excess` rises by dW while `batt_w` falls by dW and `wanted` does not move:
1350.0 W at every point across batt_w -5000..+2000 W on one banked quarter,
while the `excess` those runs see takes six distinct values. It is feed-forward,
so consuming it adds no feedback path around the plant. And HOLDING IMPLIES ZERO
OR UNKNOWN: across 1080 swept combinations not one ENGAGED decision answers a
positive headroom.

AFTER, same rig, same command. 1500/1200: 28 onsets -> 1, grid swing 3655.5 ->
282.0 W, energy bought 180.0 -> 285.2 Wh (+58%, because a continuous 300 W trade
beats a 2000 W trade cancelled for 57% of the hour), billed quarters
1490/1497/1509 -> 1500.0/1500.0/1500.0. 3500/1800: 8 -> 1, 3511/3536/3559 ->
3500/3500/3500. 3500/3000: 32 -> 1, 3519/3542/3557 -> 3500/3500/3500. The two
shipped-default rows buy 2.2% and 1.6% LESS energy and in exchange the worst
quarter goes from 59 W over the cap to zero - which is the ordering §10.1 asks
for, since the capacity tariff bills the month's single worst quarter.
⚠️ AND THE NEGATIVE CONTROL: at peak_cap_w 5000 with a 1200 W house, where
`load + max_w` never reaches the cap, the two runs are BIT-IDENTICAL.

⚠️ A NEGATIVE `lo` WAS CONSIDERED AND REJECTED, AND THE REASON IS IN THE CODE.
Deleting `decide()`'s `wanted <= 0` gate and filing `lo = wanted` is the tidier
answer arithmetically. It creates a new `lo > hi` CONTRADICTION against
main.py's cheap-window maintenance shaping, which files a NEGATIVE `hi`;
arbiter.py clause 2 has no notion of one limit out-ranking another, so it
resolves to 0 W - the battery PARKED in the quarter that sets the bill - and the
only way to close that suspends the maintenance charge shaping PERMANENTLY on
every site this card is about. A backoff or cooldown in arbitrage was rejected
too: both modules' design notes say no timer is invented, and the trade now
re-arms at `ceiling - load` rather than at max_w, which is what learning from a
refusal means when the refusal is a measurement.

THE REGRESSION IS THE LOOP SETTLING, NOT A UNIT TEST ON decide().
test_arbitrage.py 3c closes the loop over the shipped guard, strategy, arbiter,
control law and QuarterAverager with a modelled plant, and asserts BOTH
directions: unsized it must run away (24 onsets, -414..+3200 W, a quarter over
the cap) and sized it must settle (1 onset, 303 W swing, three quarters at
exactly 1500.0 W). The two runs differ in one argument. A third pair asserts the
card is INERT where the defect is inert.

Evidence: 29/29 green. 14 mutations, every one RED on a named check, no
survivors; two are ZERO BYTES - `min()` -> `max()` on the sizing, and the
sized-trade sentence's two operands transposed - and both are red. M13 reverts
the 2026-08-20 rung and is red on EIGHT named checks in test_peakguard and three
in test_arbitrage. Every revert verified by a tree fingerprint AFTER the revert,
which is how a defect in the battery's own harness was found: two edits to one
file, restored in list order, left the first one on disk (MUTATION.md habit 18).
test_peakguard.py part 1 also gained a None-safe format, because the mutation it
exists to catch made it raise TypeError one line later and ABORT the file -
parts 2-13 were ungraded and M13's recorded coverage was one check instead of
eight.

Not fixed, and named: TEST-23 finding 1's export overshoot at the END of a trade
(356-938 W, ~0.37 x max_w) is a different card; a house whose load ALONE exceeds
the cap still has the trade refused outright and the loop drive to grid = 0
rather than to the ceiling, and no swept pair reaches that regime; the container
leg (hadrive.py) was not re-run because test23s3-addon is deliberately stopped
as a second writer on the setpoint entity.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-14 16:10:34 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI — routes only, status and configuration
    config_page.py         the configuration page's markup, style and script
    configui.py            its field model, built from the Supervisor's own
                           schema + translations — owns no key, label or rule
    selfconfig.py          reading and writing this add-on's own options,
                           with the validate-first / compare-and-swap gate
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
  tools/supervisor_selfapi_probe.py  what the Supervisor really permits and
                           returns, run against its own release image
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.