Two ways a deploy of this add-on has gone wrong, and the Supervisor reports both as success. THE SILENT NO-OP. The Supervisor keys the built image by `version:`, so `ha apps update` against an unchanged version installs nothing and says it worked. PKG-06 recorded this on 2026-09-05 with six merges behind an unbumped version; PKG-07 recorded it again on 2026-09-06 with six. Both times a human noticed. Nothing else was going to. THE REFUSED CONFIG. A config the shipped validator rejects is SystemExit(78) - the add-on does not start. ⚠️ AND THE INGRESS PANEL GOES WITH IT, because the add-on serving it is not running, so recovery means the Supervisor UI. ⚠️ IT CAUGHT A LIVE ONE ON ITS OWN PULL REQUEST. Run against release/1.0 while this branch was in review: version 0.8.0 on both sides with UX-02's and OPT-09's runtime commits already merged behind it. The class this exists to catch had recurred, the same day, unnoticed - which is the argument for PKG-10, a non-required post-merge check, since this script only helps someone who remembers to run it. ⚠️ THE FIRST VERSION WAS BROKEN ON EVERY REAL REPOSITORY AND ITS TESTS COULD NOT SEE IT. The "when did the version last change" lookup was `git log -S`, the pickaxe, which finds commits that change the COUNT of a literal string. A bump edits the line IN PLACE, so the count never moves and it returned only the commit that first INTRODUCED the line. Measured here: -S ->0a1e61d2026-08-23 Packaged as a Home Assistant add-on -G ->06661c52026-09-06 PKG-07: bump 0.7.0 -> 0.8.0 so a correctly bumped tree was reported as 87 COMMITS BEHIND AN UNBUMPED VERSION, PKG-06's and PKG-07's own bump commits among the offenders. A tool whose whole purpose is to be trusted cried wolf on every run. ⚠️ AND `-G` IS NOT THE FIX EITHER, ONLY A BETTER FILTER - it matches a reformat, a quote change, a comment moved onto the line. `-G` narrows the candidates and the VALUE is then compared against the parent's. ⚠️ THREE DISTINCT SHAPES OF HABIT 4 IN ONE FILE, each found by a different means, which is the honest record of how this landed: 1. Fixtures built fresh repositories whose version line is introduced once and never edited - the one shape in which `-S` looks correct. Found by review. Answered with a three-state history; the old lookup goes red on 4 checks. 2. That three-state history still could not tell "value-compared" from "filtered-only": review swapped in `-G`'s newest raw hit and THE WHOLE SUITE STAYED GREEN, so the docstring's central claim was pinned by nothing. Answered with a cosmetic touch of the version line - `-G` matches it, the value comparison does not. That mutant now goes red on 3 checks. 3. The counts below were claimed fixed and two of them had not landed at all. Two git shapes it still gets wrong are recorded in the docstring rather than fixed - a bump resolved inside a merge commit (false refusal) and a bump reverted while the work is kept (false clearance, the dangerous direction). Neither has ever occurred here; both were constructed in review. Card PKG-11. ⚠️ AND THE PROSE COUNTS, WHICH I REPORTED AS FIXED WHEN THEY WERE NOT. Round 1 found "PKG-06 ... four merges" (its own commit message says six) and "recorded eleven times" (MUTATION.md:550 says TWELFTH). I replaced them without asserting the replacement matched, said "all applied", and round 2 found both still in the tree - one fixed in DOCS.md but not in the script, one not fixed anywhere. A claim that a correction landed is itself a claim that needs checking, and this is PROC-01's tenth instance. WHAT IT DOES NOT DO. It does not read the live box: the options blob needs the Supervisor API. Without --options the validator half SKIPS - loudly, exit 2 - and never pretends. On a bare host `app/validate.py` needs aiohttp, so that half skips too and names the container to re-run in. A missing or malformed --options file is a REFUSAL with a sentence, not a traceback. EXIT CODES: 0 cleared, 1 REFUSED, 2 NOT CLEARED. ⚠️ 2 IS NOT A PASS. Suite: 26 files, all pass. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
GoodWe RS485 Controller — Home Assistant add-on repository
Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.
repository.yaml add-on repository metadata
goodwe_controller/ the add-on
config.yaml manifest + options schema (the per-site config form)
app/ the controller
control.py the control law — pure functions, no I/O
maintenance.py the monthly cycle state machine
hass.py Supervisor/Core API access
store.py persistent state in /data
mqtt.py optional status entities
web.py ingress UI — routes only, status and configuration
config_page.py the configuration page's markup, style and script
configui.py its field model, built from the Supervisor's own
schema + translations — owns no key, label or rule
selfconfig.py reading and writing this add-on's own options,
with the validate-first / compare-and-swap gate
main.py orchestration, heartbeat, failsafe behaviour
test_control.py runnable checks — no framework needed
test_maintenance.py runnable checks — walks a full cycle in fake time
DOCS.md the add-on's documentation tab
MUTATION.md how to run a mutation so the result means something
tools/mutation_run.sh the mutation harness - purges bytecode, then grades
tools/supervisor_selfapi_probe.py what the Supervisor really permits and
returns, run against its own release image
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
estop/rs485_log.py optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4)
docs/build_guide.py its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md how to edit and rebuild the guide
Picking this up after a break? Read HANDOVER.md first — current state,
what is known broken, and what to do next.
Install
Settings → Add-ons → Add-on store → ⋮ → Repositories → add
https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon
then install GoodWe RS485 Controller.
⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it
anonymously; against a private repo the store shows nothing and gives no useful
error. If it must stay private, install locally instead: copy
goodwe_controller/ into the machine's /addons/ folder, then
ha store reload — it appears as a Local add-on.
⚠️ Bump version: in goodwe_controller/config.yaml for every change.
Supervisor keys the built image by that version, so without a bump it silently
reuses the old image and your fix appears not to work — on your bench and on
every client's machine.
Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.
Read this first
The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.
Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:
- ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
- Wind-down before firmware updates — 0 W written before the update starts.
- RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.
Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md
§10 signed.
Development
The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:
cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py
Both must pass before shipping any change. To prove a check bites - the way
almost every claim in this repository was established - mutate the module and
run tools/mutation_run.sh, which clears __pycache__ first. It is not
optional: a same-size edit reverted inside one second leaves CPython reusing the
old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md
has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre —
each assertion corresponds to a rule whose absence produced an observed failure
on real hardware, and the comments in control.py say which.
Compatibility
Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:
| tag | platform | verdict |
|---|---|---|
ESU EMU ESA BPS BPU EMJ IJL |
105 — ES/EM/BP, AA55-era meter bus | supported |
SPB SPN |
745 — SBP G2 (GW…-SBP-20) |
no |
ESN ESC |
745 — ES G2 (GW…-ES-20) |
no |
ETU EHU BTU … |
205/745/753 — ET/EH/BT hybrids | no |
SDT DST MSU NSU … |
PV-only inverters — no battery to control | no |
A "-20" or "G2" suffix means a different platform with a different meter
protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which
is also what Home Assistant's own integration uses to pick a protocol.
- GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
- The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.