EV-19 review round 1: discount a battery rise only while the meter has not moved
[Major] The rise discount applied to any rise, also one the meter
already shows, so an honest house step answered by one cycle of battery
power alarmed one cycle after base (review repro: T6 step + burst, R+6
instead of R+5). Now a reading above both earlier ones is discounted only
while the meter's house side (held - car; held alone when a car figure is
unknown) moved no more than RISE_STILL_W (50 W) since the last cycle.

Tests: the burst shapes (unit, meter in step and one cycle late;
controller, step at R+5 and R+30, 3 000 / 4 600 W) at base's second; the
"N6 unit" check tightened to the rise cycle; the RISE_STILL_W boundary;
a pin on EV-18's `_car_over_now` (mC); T10 restarts at R-1 and R (mE).
test_ev19: 144 of 144 here, 52 red on 43b0db7.