Compare commits

..
Author SHA1 Message Date
admin df154a26d1 Deploy 0.16.0 to master (#179) 2026-10-08 01:43:37 +02:00
admin 451729c9b5 Release 0.16.0 (#178)
infra-pin / fresh (push) Successful in 1s
checks / unit (pull_request) Successful in 32m56s
infra-pin / fresh (pull_request) Successful in 2s
2026-10-08 01:02:20 +02:00
goodwe-review 1c607a961a REL-0.16.0 review: CHANGELOG wording fixes
checks / unit (pull_request) Successful in 32m48s
infra-pin / fresh (pull_request) Successful in 1s
SAFETY-103 swing 'by about 800 W for about 5 s'; SAFETY-99 'late, by less
than 30 s'; MAINT-10 row: one-at-a-time is not new; SAFETY-96: drop the
test-only 800 W; SAFETY-90 and MAINT-10 rows trimmed to two sentences.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 00:09:08 +02:00
glenn schrooyenandClaude Opus 5.5 756b50ddbb Release 0.16.0
checks / unit (pull_request) Successful in 32m41s
infra-pin / fresh (pull_request) Successful in 1s
version 0.15.0 -> 0.16.0 and a closed ## 0.16.0 CHANGELOG section.
No code change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-07 23:25:14 +02:00
admin 340c7eef42 Merge pull request 'SAFETY-95: a maintenance drain that ends hands back smoothly' (#177) from safety-95-drain-end-reseed into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-10-07 17:48:53 +02:00
admin 21599938ea Merge pull request 'Deploy 0.15.0 to master' (#174) from deploy-0.15.0 into master
Deploy 0.15.0 to master (#174)
2026-10-05 10:17:38 +02:00
admin 3a54b253cb Merge pull request 'Deploy 0.14.0 to master' (#170) from deploy-0.14.0 into master
Deploy 0.14.0 to master (#170)
2026-10-03 12:32:16 +02:00
admin 8b9680fc35 Merge pull request 'Deploy 0.13.0 to master' (#166) from deploy-0.13.0 into master
Reviewed-on: #166
2026-10-02 15:26:46 +02:00
admin 3ce18708b6 PKG-18: ship 0.12.0 to master, so TEL-12's pv_entities can reach an installed 0.11.0 (#118) 2026-09-24 23:22:34 +02:00
adminandClaude Opus 5 78acb558ff PKG-17: ship 0.11.0 to master, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1 (#115)
master is what the Home Assistant Supervisor clones, and the Supervisor
compares config.yaml version strings - so 0.11.0 could not be offered to an
installed 0.10.1 without this bump reaching master.

Carries SAFETY-56 (#112), TEL-11 (#113), the CI-9 follow-up (#102) and SEC-2's
docs/RELEASE.md (#108), by way of the 0.11.0 cut (#114).

NOT A FAST-FORWARD. master was not an ancestor of release/1.0: 0f14c2a, the
pre-SEC-2 direct push, exists only on master. Its tree is the same object as
the merge base b0b24e5 (c1fef26), so it carries no content delta, and
`git merge-tree --write-tree` over the two branches returns a tree bit-identical
to cccb2fa's own (6670502). This merge commit therefore contributes exactly
release/1.0's tree - master synthesises nothing.

Reviewed as the release decision, not a re-review of content. Verified from the
remote: slug goodwe_controller and every identity key unchanged (cross-checked
against the live box's Supervisor export), version 0.10.1 -> 0.11.0, and the
green is this PR's own - run 828 / job 1953, path checks.yml@refs/pull/115/head,
PRNUM 115, GRADED refs/pull/115/head merged into master, run_attempt 1, 31 test
files all passing in 8m01s of real work.

predeploy_check.py re-run against the owner's current options (exported
2026-09-24 20:02, 75 keys, pv_entity unset): CLEARED, exit 0. That retires the
stale-2026-09-07-export warning in the pull request body. Option surface
75 -> 76 with only pv_entity added, str? defaulting to "", no key removed, no
default moved, no rule added to validate.py - no SystemExit(78) on this hop.

Merging is not installing. No tag is cut here and `ha store reload` /
`ha addons update` have not been run.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 20:28:35 +02:00
glenn schrooyenandClaude Opus 5 0f14c2a5de PKG-16: ship 0.10.1 to master, so the Supervisor can offer SAFETY-57's fix
master is what Home Assistant clones. SAFETY-57 fixed a deadlock that parked
the reference install's battery for ~13 minutes while the site exported
2.4 kW, and the Supervisor compares config.yaml version strings - so the fix
could not reach an installed 0.10.0 without this bump reaching master.

Brings SAFETY-57 (#104) and the 0.10.1 cut (#105). master was a strict
ancestor; no conflict was possible.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-22 15:54:29 +02:00
2 changed files with 45 additions and 1 deletions
+44
View File
@@ -1,5 +1,49 @@
# Changelog
## 0.16.0
**A minor bump: changed behaviour, no option added or removed, and one default
and its meaning changed.** There are still 83 options. `maintenance_start_hour`
used to be read as UTC and its default was 10. It is now a local hour (in Home
Assistant's time zone) and its default is 19. The other changes below apply
with one inverter or two, unless a line says "Two inverters".
**Before you update (MAINT-10).** A saved `maintenance_start_hour` is kept, and
it now means local time. If you set it in UTC to get an evening start (for
example 17 for 19:00 in summer), set it back to the local hour (19). A saved
10 now starts at 10:00, not 12:00 in summer. The new default 19 only reaches
installs that have no hour saved.
Contents of this release, in merge order since 0.15.0 (`3ed3302`):
| | |
|---|---|
| `7ef7347` | After a gap in the P1 meter, the peak guard counts the missed time as high use and keeps the 15-minute period near the limit; before, it was blind until the next period. In the test, a 5 min meter silence at one inverter ended the period at 3.3 kW, against 4.8 kW on 0.15.0 ([[SAFETY-90]]) |
| `1bf6b7f` | The maintenance start hour is now a local hour, and its default is 19 (was 10, read as UTC). The log says which time zone it used; with two inverters, both use that hour and still cycle one at a time ([[MAINT-10]]) |
| `b2f5573` | Two inverters: when one battery's link drops, the other takes over in small steps, and control no longer stalls. The battery that comes back rejoins within 2 s, without a false "battery refuses" ([[SAFETY-96]]) |
| `340c7ee` | Two inverters: when a drain ends (done, switched Off, timeout, lost link), the other battery covers the house right away, without jumping to 1.6 kW, and then moves in small steps. It no longer gives into a solar surplus ([[SAFETY-95]]) |
### Known issues
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
- A battery whose reading at rest is beyond about ±170 W is still not caught when it refuses, as in 0.14.0 ([[SAFETY-97]]).
- The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s ([[SAFETY-99]]).
- A charge to 100 % can time out at 98 %. The add-on then counts the cycle as failed and drains the battery again the next day ([[MAINT-13]]).
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
- Two inverters: after a drain ends, the other battery can swing by about 800 W for about 5 s, because some readings are old ([[SAFETY-103]]).
- Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]).
- Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]).
- One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]).
### If you are crossing from a version older than 0.10.0
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
bare options (`jq '.data.options'`) first.
## 0.15.0
**A minor bump: changed behaviour, and no option changes.** No option was
+1 -1
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller
version: "0.15.0"
version: "0.16.0"
slug: goodwe_controller