Compare commits
17
Commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
8b9680fc35 | ||
|
|
8c438ab2e6 | ||
|
|
b37b7f95dc | ||
|
|
28cab03947 | ||
|
|
61072ca460 | ||
|
|
7b723a6cd5 | ||
|
|
4b81387908 | ||
|
|
935878193b | ||
|
|
b4d25dd485 | ||
|
|
a4a04d203c | ||
|
|
aa501ffec7 | ||
|
|
d89c093318 | ||
|
|
d0db5b8c39 | ||
|
|
b8ddfd787f | ||
|
|
3ce18708b6 | ||
|
|
78acb558ff | ||
|
|
0f14c2a5de |
@@ -1,5 +1,95 @@
|
||||
# Changelog
|
||||
|
||||
## 0.13.0
|
||||
|
||||
**A minor bump: new behaviour, a new add-on page (Home, Settings, Batteries,
|
||||
Setup), and six new options.** No option was removed or renamed, and no
|
||||
default of an existing option changed (77 options -> 83). The only new
|
||||
start-up checks are on the new options, so options that start 0.12.0 also
|
||||
start 0.13.0.
|
||||
|
||||
New options, and what they do if you leave them alone:
|
||||
|
||||
| option | default | left alone |
|
||||
|---|---|---|
|
||||
| `peak_margin_w` | `50` | the peak guard aims 50 W below your peak limit, or below a higher peak already reached this month; `0` is the old aim ([[SAFETY-79]]) |
|
||||
| `battery_modes_enabled` | `false` | no battery modes, control as before ([[OPT-11]]) |
|
||||
| `pv_forecast_entity`, `pv_forecast_tomorrow_entity` | empty | no solar forecast is used ([[OPT-11]]) |
|
||||
| `solar_trust_pct` | `70` | only used with a solar forecast ([[OPT-11]]) |
|
||||
| `pv_invert_entities` | `[]` | PV readings as before ([[TEL-14]]) |
|
||||
|
||||
⚠️ **Turn on Watchdog** on the add-on's Info tab. It is off by default. If
|
||||
the control loop crashes, the add-on now sets the batteries to 0 W and stops.
|
||||
Home Assistant only starts it again when Watchdog is on ([[SAFETY-61]],
|
||||
[[DOC-5]]).
|
||||
|
||||
⚠️ **The peak guard now starts a little earlier.** It aims 50 W below your
|
||||
peak limit, so the batteries give a bit more at peak times. Set
|
||||
`peak_margin_w: 0` for the old aim ([[SAFETY-79]]).
|
||||
|
||||
Contents of this release, in merge order since 0.12.0 (`a45ed06`):
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `fa3d237` | Docs name the right P1 age entity and a battery list that starts ([[DOC-1]]) |
|
||||
| `6e65272` | If the control loop crashes, the batteries go to 0 W and the add-on stops ([[SAFETY-61]]) |
|
||||
| `3e38baf` | The check tools refuse a file they cannot read, instead of saying all clear (tools only) ([[SAFETY-60]], [[SAFETY-62]]) |
|
||||
| `43b2740` | A missing value in a check is a named failure (tests only) ([[TEST-26]]) |
|
||||
| `20260e8` | Docs: turn on Watchdog ([[DOC-5]]) |
|
||||
| `16c796f` | New option `pv_invert_entities`: flip the sign of a PV sensor that reads backwards ([[TEL-14]]) |
|
||||
| `6a8a5ff` | CI tests against the real inverter simulator (CI only) ([[CI-12]]) |
|
||||
| `82f032e` | CI pin checks report failures properly (CI only) ([[TOOL-9]]) |
|
||||
| `fe13251` | CI pin update (CI only) |
|
||||
| `397dd15` | Alarm notifications that are still active come back after a Home Assistant restart ([[SAFETY-34]]) |
|
||||
| `59415ea` | CI pin update (CI only) |
|
||||
| `2503de1` | "Battery is not keeping up" is a warning with its own notification, not a "bug" alarm; its figures are correct ([[SAFETY-40]]) |
|
||||
| `48ef06a` | Shorter, plainer notifications ([[UX-08]]) |
|
||||
| `5c151a3` | CI pin update (CI only) |
|
||||
| `d57767f` | Shorter, plainer status rows and banners ([[UX-08]]) |
|
||||
| `e1d0970` | Details link works on current Home Assistant; plainer words ([[UX-09]]) |
|
||||
| `a02cd4b` | Shorter refusals, errors and option texts ([[UX-08]]) |
|
||||
| `32b9e56` | Plainer log lines and docs ([[UX-08]]) |
|
||||
| `125b070` | CI pin update (CI only) |
|
||||
| `2b14b88` | Last plain-language fixes in logs and the status page ([[UX-10]]) |
|
||||
| `c4032eb` | CI pin update (CI only) |
|
||||
| `d1f7e33` | Safety log lines: one plain sentence and a code ([[UX-11]]) |
|
||||
| `652097a` | A battery that refuses power (e.g. empty) is asked for 0 W, and tried at 200 W for 34 s every 15 min ([[SAFETY-52]]) |
|
||||
| `afd6af0` | Groundwork for the new settings pages ([[UX-13]]) |
|
||||
| `a36dca6` | New page with a Home screen ([[UX-13]]) |
|
||||
| `28a49cc` | With two or more inverters, a battery that refuses power is held on its own; the others take over ([[SAFETY-73]]) |
|
||||
| `515c11b` | New Installer settings view ([[UX-13]]) |
|
||||
| `4de9675` | New setup wizard for installers ([[UX-13]]) |
|
||||
| `8c34647` | A new install with no inverter opens the setup wizard instead of stopping ([[UX-15]]) |
|
||||
| `a5dddad` | Dutch text and a time-period editor ([[UX-13]]) |
|
||||
| `ed739d4` | Battery modes (off by default): per-battery limits, on/off, solar order ([[OPT-11]]) |
|
||||
| `7995e4d` | Simple settings view and a Batteries screen ([[UX-13]]) |
|
||||
| `7337b79` | Battery modes in Home Assistant, when modes are on ([[OPT-11]]) |
|
||||
| `7a00f12` | New option `peak_margin_w`: the peak guard keeps a margin below the limit ([[SAFETY-79]]) |
|
||||
| `5a4cdc2` | Battery modes: charge in cheap hours, hold for expensive hours; selling is off for now ([[OPT-11]]) |
|
||||
| `4f25b24` | No false "Load too high" alarms at quarter edges or with a noisy load (10 s hold) ([[SAFETY-81]]) |
|
||||
| `35cdffe` | Maintenance drain with two batteries no longer stalls ([[SAFETY-78]]) |
|
||||
| `1145a93` | Battery modes: a solar forecast decides how much to buy from the grid ([[OPT-11]]) |
|
||||
| `9d5b7d1` | With one battery, the peak guard wins over the maintenance drain ([[SAFETY-83]]) |
|
||||
| `4ad8298` | Maintenance charge with two batteries no longer stalls; it gives way to the peak guard ([[SAFETY-84]]) |
|
||||
| `b8ddfd7` | The peak guard wins over the maintenance hold; the hold ends on time, with no top-up ([[SAFETY-86]]) |
|
||||
| `9358781` | With two or more batteries, the peak guard uses every battery that can still give; peak alarms no longer say control stopped ([[SAFETY-87]]) |
|
||||
| `61072ca` | No false "Battery is not keeping up" during maintenance; real shortfalls still warn; the status row counts each episode once ([[SAFETY-85]]) |
|
||||
|
||||
### Known issues
|
||||
|
||||
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
|
||||
- Two inverters: at the end of a maintenance charge one battery can charge from the grid while the house uses a lot. Do not add a second inverter before the next release ([[SAFETY-93]]).
|
||||
- A healthy battery that turns from charging to giving can be held at 0 W for up to 15 min ([[SAFETY-94]]).
|
||||
- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]).
|
||||
- Two batteries: one at its peak reserve can be used before a draining battery has used its room ([[SAFETY-91]]).
|
||||
|
||||
### If you are crossing from a version older than 0.10.0
|
||||
|
||||
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
|
||||
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
|
||||
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
|
||||
bare options (`jq '.data.options'`) first.
|
||||
|
||||
## 0.12.0
|
||||
|
||||
**A MINOR BUMP FOR ONE NEW OPTION: `pv_entities` ([[TEL-12]]), for sites with
|
||||
|
||||
@@ -69,6 +69,8 @@ which does not run the startup gate) the absence costs a shave and never a pack.
|
||||
|
||||
## 3. DECISION 2 — the site verdict is the MAXIMUM of the packs' own floors
|
||||
|
||||
*At N>=2 one pack at its floor no longer stops the others: [[SAFETY-87]].*
|
||||
|
||||
`Controller.pack_floor_soc` — the **minimum** measured SoC, the emptiest pack —
|
||||
**is unchanged**, exactly as the card instructed. What changed is the floor it is
|
||||
graded against. `peakguard.binding_soc_floor()` reduces the roster's per-pack
|
||||
|
||||
@@ -0,0 +1,91 @@
|
||||
# SAFETY-85 - no false "not keeping up" while another owner sets the battery
|
||||
|
||||
**Status: implemented 2026-10-01, for review.** Tests: `test_safety85.py`.
|
||||
|
||||
**The defect.** "Battery is not keeping up" (SAFETY-40, `goodwe_integrator_bound`)
|
||||
fired about every 2.5 min during maintenance (drain, charge, HOLD) and under the
|
||||
peak guard, while the battery gave exactly what it was told. Each warning
|
||||
re-created the HA notification. Rig counts: 24 in an hour (SAFETY-83 F1), 43 in
|
||||
7 episodes (SAFETY-86), 35 in 16 (SAFETY-87), 12 in 6 (SAFETY-84). The page
|
||||
counter counted cycles (861), not episodes.
|
||||
|
||||
**Cause, measured on the real Controller.**
|
||||
- N=1: when a higher claim decides, `cycle()` re-seeds the integrator from the
|
||||
target each cycle, then `compute()` adds `gain * error` for a grid error the
|
||||
loop does not own. Target + kick crosses the rail and sets `i_clamped`. The
|
||||
carried integrator is not wound (SAFETY-48 caps the lead at one slew step),
|
||||
so control comes back one slew step at a time.
|
||||
- N>=2: a maintenance pin is a unit claim. The loop stays the site winner and
|
||||
winds to its rail for watts the pinned battery may not give. When the pin
|
||||
lifts, the site jumps: 2500 W in one cycle when a HOLD ends under a 4500 W
|
||||
house, 1390 W when a charge pin lifts (`s84 n2_charge_dear`, t=1800 s).
|
||||
|
||||
**Decision.** Three rules; the alarm, its text and its id are unchanged.
|
||||
1. **The loop's clamp counts only on a cycle the loop decided.** The winner is
|
||||
the loop. Its number is on the wire, or only a rating (`device`,
|
||||
`supervised`) cut it. No bound held it, and nothing was unmet.
|
||||
(`Controller._loop_alarm_input`.)
|
||||
2. **A battery another owner set to discharge alarms when it gives less than
|
||||
it was told.** This covers every battery on a cycle the loop did not
|
||||
decide, and a battery with its own pin otherwise. The test is more than
|
||||
`saturation_w` short of the least it stood at over `SHORT_CYCLES` cycles
|
||||
and `SHORT_SPAN_S` (the plant's measured settle, SAFETY-13/73), for
|
||||
`saturation_cycles` cycles in a row (`clamp.delivery_short`). It covers a
|
||||
real shortfall during maintenance or under the peak guard. Before, that
|
||||
shortfall was silent unless the kick happened to reach the rail (house
|
||||
1000 W, drain 2000 W, battery gives nothing: 0 warnings before, 4 in 10 min
|
||||
now).
|
||||
3. **At N>=2, while maintenance holds a battery, the loop is bounded** by
|
||||
OPT-11's `loop_bound()` (what the batteries may place). It does not wind,
|
||||
and control comes back one slew step a cycle. Why maintenance only: that is
|
||||
where the jump was measured and where the owner order puts maintenance
|
||||
above the loop. Other N>=2 limits (pack cut-out, SAFETY-73 refusal) keep
|
||||
the old law. Rule 1 still silences them (the target is unmet), so they no
|
||||
longer warn either.
|
||||
|
||||
Fixing the windup was chosen over only ignoring the wound part, because at
|
||||
N>=2 the wound integrator moves real watts at hand-back. At N=1 there was
|
||||
nothing to fix: re-seeding already prevents windup.
|
||||
|
||||
**What SAFETY-03/40 protect is kept.** With the loop in charge, the integrator
|
||||
bound still warns (a runaway, a house above the rating), and a saturated
|
||||
inverter under the loop's own command still does not alarm (SAFETY-03 AC 2):
|
||||
rule 2 grades only batteries another owner set.
|
||||
|
||||
**The counter.** `ClampWatchdog.bound_episodes` counts episodes that had a
|
||||
bound engagement. The status row shows it ("N times since start").
|
||||
`bound` (cycles) stays for the log and the tests.
|
||||
|
||||
**Re-pinned digests.** Every change is intended; nothing at N=1 moves a watt.
|
||||
|
||||
| digest | what changed |
|
||||
|---|---|
|
||||
| s78 `n1_drain_owner` | the false clamp rows are gone from the log; commands identical |
|
||||
| s78 `n2_drain`, s84 `n2_charge`, `n2_charge_banked`, s79 `n2_maint` (test_peak_margin) | loop reason (`mode-bound`), integrator and loop claim while bounded; commands identical |
|
||||
| opt11 `n2_maint` (test_modes) | A drops out at t=1655 s: B follows the house at once, 8 cycles differ (max 920 W) |
|
||||
| s84 `n2_charge_dear` | A's pin lifts at t=1800 s: 400 W a cycle, not a 1390 W jump; the surplus step after it; 98 cycles |
|
||||
|
||||
test_safety86's "without the ceiling the log floods" now needs the ceiling
|
||||
and the bound both removed: either one alone keeps the loop inside what the
|
||||
batteries can give. The `alarmed()` helpers in test_safety84/86 also read
|
||||
SAFETY-81's quarter stamp, because ALLOCATOR rows can push its row out of
|
||||
the 40-row log.
|
||||
|
||||
**Review (PR #163).** The first draft graded each battery against last
|
||||
cycle's command and graded charges too. On plantsim's battery (10 s lag) at
|
||||
the live 2 s meter, every drain or charge start warned once, and an N=2 drain
|
||||
or HOLD under the peak guard with a stepping house warned 15 times an hour. A
|
||||
maintenance charge tapering near full warned 11 times in 50 min, which
|
||||
SAFETY-42 section 7 had ruled out. With the settle window and discharge only:
|
||||
0 in all of those cases. A battery that gives nothing still warns, lagging
|
||||
or not. At a hypothetical 20 s lag, it warns at most twice an hour. The cost:
|
||||
a battery that does not take a charge another owner set is not named by this
|
||||
alarm (the same gap SAFETY-42 states; the charge has its 36 h timeout).
|
||||
`test_safety85.py` part 7.
|
||||
|
||||
**Not changed, open for the owner.**
|
||||
- With the loop in charge and the house above the batteries' total rating,
|
||||
it still warns (SAFETY-40). On the rig's 2 x 2000 W N=2, most of SAFETY-84's
|
||||
count came from houses of 4500 and 6500 W.
|
||||
- TEL-10's `Loop reason` reads `mode-bound` while the maintenance bound holds
|
||||
the loop, with modes off. DOCS lists the value with both meanings.
|
||||
@@ -0,0 +1,83 @@
|
||||
# SAFETY-87 - the peak guard uses every battery that can still give
|
||||
|
||||
**Status: DECIDED 2026-10-01 (owner card).** Follows SAFETY-86's "Not
|
||||
changed" list. Tests: `test_safety87.py`; identity:
|
||||
`tools/safety87_identity.py`.
|
||||
|
||||
**The defect.** At N>=2 the guard graded the emptiest battery against the
|
||||
highest floor ([[SAFETY-32]] §3). One battery under `peak_soc_floor` made the
|
||||
whole site floor-limited: the claim asked for 0 W and the reserve alarm fired,
|
||||
even with the other battery full. Measured: a maintenance charge (A at 11 %)
|
||||
raised the alarm 10 times while both batteries gave 2000 W and the quarter
|
||||
landed on the aim (SAFETY-84 rig test, check 3); a HOLD (A at 99 %, B at
|
||||
15 %) left A at 0 W and banked 4051 W, raising the month peak (SAFETY-86
|
||||
review; rig case 7a: 4563.8 W).
|
||||
|
||||
**The fix.**
|
||||
- `decide()` and its call are unchanged. At N>=2 `Controller._peak_on_able()`
|
||||
then grades each battery on its own floor (`peakguard.reserve_split()`).
|
||||
One at or under it is *held*. The others that are live and not refusing
|
||||
(SAFETY-73) are *able*.
|
||||
- A floor-limited decision is re-taken on the able batteries
|
||||
(`peakguard.place_on_able()`): their own permission (min SoC against max
|
||||
floor, among them), and a floor of `min(need, able_w)`. `able_w` is their
|
||||
rating plus the drain a held battery gives anyway (its maintenance pin).
|
||||
- The held batteries weigh 0 in the split while the site gives
|
||||
(`arbiter.resolve(reserve=)`), so the floor lands on the able ones. During a
|
||||
HOLD, a held battery is not counted among the "others" (`_peak_over_hold()`),
|
||||
so the holding battery covers the need.
|
||||
- Floor-limited now means: some battery is held and the able ones cannot hold
|
||||
the aim. The claim still asks them for `able_w`. The alarm fires only if
|
||||
they miss the real limit at full power for `ALARM_HOLD_S`, the same test as
|
||||
'Load too high' (`_reserve_short()`), so a one-cycle miss at a quarter's end
|
||||
is not an alarm. With nothing able (all held, or the rest refusing or
|
||||
dropped) it is the old state: 0 W, immediate alarm.
|
||||
- The alarm and the row name `held`, each battery graded on its own floor. The
|
||||
old code named batteries against the site's highest floor.
|
||||
- Page: the two peak rows carry `runs`. A red `runs` row gives the banner its
|
||||
title without "Not ready", and the Home page is not shown as held at 0 W.
|
||||
Rows that do stop control still outrank it.
|
||||
|
||||
**How SAFETY-32's concern is still covered.** SAFETY-32 took min(SoC) against
|
||||
max(floor) so the guard never sizes a forced discharge a battery's own BMS
|
||||
stops. Now no battery at or under its own floor is asked for the peak: it is
|
||||
graded on its own floor, and an unread SoC or unknown cut-out counts as held.
|
||||
The min/max pairing still decides permission, over the able batteries. The
|
||||
roster verdict `decide()` echoes (`soc`, `soc_floor`) is kept, so SAFETY-32's
|
||||
call-site and reduction checks still bite. What changed is only that one held
|
||||
battery no longer stops the others. One exception, with battery modes on: see
|
||||
Open.
|
||||
|
||||
**Maintenance pins beside a held battery** (review). A draining battery that
|
||||
may still give is raised from its drain rate towards its rating for the peak
|
||||
floor, after the others (`_drain_over_reserve()`; peak > drain), else the
|
||||
floor's rest landed on the held battery. In a HOLD, a held battery counts its
|
||||
own pin (a drain) among the others, and a held battery pinned to charge stops
|
||||
the raise (never split both ways).
|
||||
|
||||
**Before -> after** (test_safety87.py, rig of 2 x 2500 W, aim 3450 W):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| charge, A 11 %, house 4500 | 3 reserve alarms, quarter 3450 | 0 alarms, 3450 |
|
||||
| HOLD, A 99 % / B 15 %, house 5500 | A 0 W, B 2488 W, 3 alarms | A 2054 W, B 0 W, 0 alarms, 3450 |
|
||||
| HOLD, house 6500 | A 0 W, B 2488 W, 4051 W | A 2500 W, B 0 W, 4014 W, 1 alarm (A alone is short) |
|
||||
| HOLD, month peak 4000, house 6000 | A 0 W, B 2488 W, 3551 W, alarms | A 2054 W, B 0 W, 3950 (peak - margin), 0 alarms |
|
||||
| both under the reserve | alarm | alarm (unchanged) |
|
||||
| N=1, every scenario | | byte-identical |
|
||||
|
||||
**Open, for the owner.**
|
||||
- The loop still draws a held battery (SAFETY-25 option A: the reserve binds
|
||||
the peak guard only). It gives last, after the able ones. So with house 6500
|
||||
in the charge case, B alone cannot hold the aim, the alarm fires as
|
||||
specified, and the loop then lands the quarter on the aim from A. The text
|
||||
says "cannot keep … alone", not "will go over", so it stays true.
|
||||
- Battery modes on, A Off and B held: when B alone can place the floor, OPT-11
|
||||
keeps A resting and B gives it. When B cannot, A gives first. Making Off give
|
||||
before a held battery in the first case needs a third allocator tier. The
|
||||
same at N=3: A Off, B held, C able, floor 4000 W gives C 2500, B 1500, A 0.
|
||||
Until then, with modes on, a held battery can give for the peak.
|
||||
- The notification and row text live in `messages.py`, which has no NL layer
|
||||
yet (UX-19). The Home page text, which has NL, is unchanged.
|
||||
|
||||
**Not changed.** N=1. 'Load too high' (SAFETY-81). SAFETY-85, -88, -89, -90.
|
||||
@@ -577,7 +577,7 @@ accumulator is doing:
|
||||
| `Loop integrator lead` | W | that value minus **the command it was computed against**, i.e. the command the previous cycle left standing |
|
||||
| `Loop reason` | — | the law's own word for this cycle |
|
||||
|
||||
`Loop reason` takes one of ten values:
|
||||
`Loop reason` takes one of eleven values:
|
||||
|
||||
| value | what happened |
|
||||
|---|---|
|
||||
@@ -588,6 +588,7 @@ accumulator is doing:
|
||||
| `slew-limited` | the command could not move as far as the integrator asked for; `slew_w` is what stopped it |
|
||||
| `saturated-freeze` | the inverter is not following, so the command's magnitude may fall but not rise |
|
||||
| `freeze-released` | the freeze had run out of plant-shaped explanations and the command was let move again |
|
||||
| `mode-bound` | the batteries' limits set the command, not the meter: their battery modes, or, with two or more inverters, a battery in its monthly maintenance |
|
||||
| `not-running` | control is stopped **and** shadow mode is off, so the loop did not run |
|
||||
| `battery refuses` | the battery gave less than 100 W for 12 cycles (a minute at a 5-second meter) while asked for more than 500 W, so the add-on asks 0 W in that direction (see below) |
|
||||
| `battery probe` | the add-on asks 200 W to test whether a refusing battery gives power again |
|
||||
@@ -1639,7 +1640,7 @@ help - see "Why the tuning is what it is".
|
||||
| `maintenance_enabled` | false | Enable the monthly cycle |
|
||||
| `maintenance_interval_days` | 28 | Minimum gap between cycles |
|
||||
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
|
||||
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). The peak guard may ask for more (SAFETY-83). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
||||
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). The peak guard may ask for more (SAFETY-83; at N≥2 while another battery is at its peak reserve, SAFETY-87). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
||||
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
|
||||
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor. ⚠️ **This is not `peak_soc_floor`.** It is the depth the monthly recalibration deliberately goes to, once, on purpose; `peak_soc_floor` is the depth a money-saving discharge may never reach on any day. The right values differ (11 vs 20 as shipped), which is why they are two keys |
|
||||
| `maintenance_soc_target` | 99 | Charge target |
|
||||
@@ -1953,6 +1954,15 @@ over the rating is logged as a software fault, at `ERROR`, and it has its own
|
||||
notification budget.
|
||||
Why: [`DECISIONS/SAFETY-40-the-integrator-bound-is-not-a-bug.md`](DECISIONS/SAFETY-40-the-integrator-bound-is-not-a-bug.md).
|
||||
|
||||
The integrator bound counts only on a cycle the loop decided. While
|
||||
maintenance, the peak guard or a safety limit sets a battery to discharge, the
|
||||
same alarm fires only when that battery gives more than `saturation_w` less
|
||||
than the least it was told over the plant's settle time (at least 23 s), for
|
||||
`saturation_cycles` cycles. A charge is not graded: a full battery takes less
|
||||
as it tops up. At two or more inverters the loop does not wind while
|
||||
maintenance holds a battery.
|
||||
Why: [`DECISIONS/SAFETY-85-no-false-not-keeping-up.md`](DECISIONS/SAFETY-85-no-false-not-keeping-up.md).
|
||||
|
||||
### The frozen-meter alarm
|
||||
|
||||
A meter that has died is easy — it stops answering, the sample age climbs past
|
||||
@@ -3122,7 +3132,10 @@ The battery gives less power than the add-on asks for. This is normal for a
|
||||
short time, for example just after a large load switches on or the sun comes
|
||||
out. It is not a fault, and control keeps running. If it keeps coming back,
|
||||
check that the battery is switched on, and that it is not empty (when it should
|
||||
give power) or full (when it should charge).
|
||||
give power) or full (when it should charge). During the monthly maintenance or
|
||||
while the peak limit is guarded, it only shows when the battery gives
|
||||
clearly less than it was told. The status page counts how many times it
|
||||
happened.
|
||||
|
||||
### Power request too high
|
||||
|
||||
@@ -3157,6 +3170,10 @@ and what to do:
|
||||
- **A battery cut-out level is not known.** Fill in “Battery cut-out level”
|
||||
for each inverter in the settings.
|
||||
|
||||
With several inverters, a battery at its peak reserve does not give for the
|
||||
peak and the others do. This alarm then comes only when the others cannot
|
||||
keep the period under the limit alone. Control keeps running meanwhile.
|
||||
|
||||
The peak reserve only applies to keeping the peak down. Normal home use can
|
||||
still draw the battery below it, down to the battery cut-out level, where the
|
||||
battery switches itself off.
|
||||
@@ -3223,8 +3240,9 @@ section without a link. The documentation tab adds no heading anchors, so the
|
||||
link cannot jump to the section.
|
||||
|
||||
**Battery is not keeping up.** The grid-following loop's integrator reached its
|
||||
anti-windup bound (`integrator_max_w`, SAFETY-40). No command went over the
|
||||
rating. The log line is a WARNING with reason code `OUTPUT_CLAMP`. See *The
|
||||
anti-windup bound (`integrator_max_w`, SAFETY-40), or a battery that another
|
||||
owner set to discharge gave less than it was told (SAFETY-85). No command went
|
||||
over the rating. The log line is a WARNING with reason code `OUTPUT_CLAMP`. See *The
|
||||
winding-loop alarm*.
|
||||
|
||||
**Power request too high.** A computed command above a limit was cut before it
|
||||
@@ -3252,7 +3270,9 @@ state of charge is unread, or when an inverter's `bms_soc_floor` (label
|
||||
“Battery cut-out level”) is missing, because the reserve is graded against it.
|
||||
Charging from the grid stays blocked meanwhile. With several inverters the
|
||||
notification names the battery at its limit (SAFETY-32), each graded against
|
||||
its own cut-out level. ⚠️ **The reserve binds the peak guard only
|
||||
its own cut-out level. That battery is held (weight 0 while the site gives)
|
||||
and the guard's need goes to the others, up to their rating; the alarm fires
|
||||
only if they miss the limit at full power for `ALARM_HOLD_S` (SAFETY-87). ⚠️ **The reserve binds the peak guard only
|
||||
(SAFETY-25).** Self-consumption has no such floor. See *What `peak_soc_floor`
|
||||
does not protect*.
|
||||
|
||||
@@ -3390,7 +3410,7 @@ for a new install*.
|
||||
| Meter reading may be stuck | See *Meter reading may be stuck* under Notifications. |
|
||||
| Month peak | This month's highest 15-minute average, when it happened, and how close it is to your peak limit. Amber from 80 %. |
|
||||
| 15-minute periods measured this month | How many 15-minute periods the add-on has measured and saved this month. |
|
||||
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. *Idle, heading for …* is where this 15-minute period is heading. *Waiting for meter readings* after a restart means the battery does not charge until the add-on can measure the period again. |
|
||||
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. *Idle, heading for …* is where this 15-minute period is heading. *Waiting for meter readings* after a restart means the battery does not charge until the add-on can measure the period again. A red peak row is an alarm while control keeps running, so the banner shows its title without *Not ready*. |
|
||||
| Battery level, Battery power, Grid power | The reading of that entity. *No usable reading* means the entity is missing, or its reading is too old. Check it in Developer Tools before replacing it. |
|
||||
| Inverter control | Whether the inverter can be controlled, and how much it can charge and give. |
|
||||
| *name*: battery power reading stopped changing | The reading did not change while the add-on asked for a change. It may be stuck, or the battery may be refusing. The add-on sets the inverters to 0 W until it changes. |
|
||||
|
||||
@@ -635,7 +635,7 @@ def site_resolve(claims: list) -> Resolution:
|
||||
|
||||
|
||||
def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
tick=None) -> Resolution:
|
||||
tick=None, reserve=()) -> Resolution:
|
||||
"""The three stages, in order, over one cycle's claims.
|
||||
|
||||
`units` is the site's roster of inverters. Left None it is derived from the
|
||||
@@ -737,6 +737,13 @@ def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
gate, held = _unit_modes(out, site_claims, bounds, live)
|
||||
if callable(weights):
|
||||
weights = weights(out.target_w)
|
||||
# SAFETY-87: units under their peak reserve weigh 0 while the site gives,
|
||||
# so the others carry the peak floor. An Off battery gives the peak's
|
||||
# shortfall, so it goes before them when no other unit is left.
|
||||
reserve = set(reserve) if out.target_w > 0.0 else set()
|
||||
if held and reserve and not set(bounds) - held - reserve:
|
||||
held = set()
|
||||
held = held | reserve
|
||||
if held:
|
||||
weights = {u: (0.0 if u in held else
|
||||
(1.0 if weights is None else weights.get(u, 1.0)))
|
||||
|
||||
@@ -260,6 +260,22 @@ def loop_clamp_note(d) -> str:
|
||||
return ""
|
||||
|
||||
|
||||
def shortfall_note(named) -> str:
|
||||
"""SAFETY-85: the alarm text while another owner sets the batteries.
|
||||
`named` is `[(inverter name or None, asked W, given W)]`, one per battery
|
||||
that gave less than asked."""
|
||||
return f"{REASON_CODE}: " + ", ".join(
|
||||
f"{name or 'the battery'} gives {given:+.0f} W of the {asked:+.0f} W "
|
||||
f"asked" for name, asked, given in named)
|
||||
|
||||
|
||||
def delivery_short(asked_w, given_w, margin_w) -> bool:
|
||||
"""SAFETY-85: did a battery asked to discharge give more than `margin_w`
|
||||
less? A charge is never short: a full pack tapers (SAFETY-42 section 7)."""
|
||||
asked, given = float(asked_w), float(given_w)
|
||||
return asked > 0.0 and asked - given > abs(float(margin_w))
|
||||
|
||||
|
||||
def write_clamp_note(named) -> str:
|
||||
"""The write-side alarm text: `named` is `[(inverter name or None,
|
||||
ClampResult)]` for every inverter whose write was cut back this cycle.
|
||||
@@ -382,6 +398,10 @@ class ClampWatchdog:
|
||||
self.over_rating = 0 # bug=True: "Power request too high"
|
||||
self.bound = 0 # bug=False: "Battery is not keeping up"
|
||||
self.episodes = 0 # rising edges
|
||||
# SAFETY-85: episodes with a bug=False engagement. The status row
|
||||
# counts these; counting cycles read 861 on one rig run.
|
||||
self.bound_episodes = 0
|
||||
self._bound_counted = False
|
||||
self.since: datetime | None = None
|
||||
self.last_alarm: datetime | None = None
|
||||
self.reason = ""
|
||||
@@ -436,6 +456,10 @@ class ClampWatchdog:
|
||||
self.spoken = False
|
||||
self.bug = False
|
||||
self.bug_spoken = False
|
||||
self._bound_counted = False
|
||||
if not bug and not self._bound_counted:
|
||||
self._bound_counted = True
|
||||
self.bound_episodes += 1
|
||||
if bug or not self.bug:
|
||||
self.reason = reason
|
||||
self.facts = tuple(facts)
|
||||
|
||||
@@ -382,6 +382,9 @@ class Decision:
|
||||
# SAFETY-52. The refused direction to carry back in (+1 discharge, -1
|
||||
# charge, 0 none), or None when the caller does not carry it.
|
||||
refused: int | None = None
|
||||
# SAFETY-85. The `bound` held the integrator or the command this cycle,
|
||||
# so the batteries' limits, not the loop, decided it.
|
||||
held: bool = False
|
||||
|
||||
|
||||
def slew_limit_w(tuning: Tuning) -> float:
|
||||
@@ -614,11 +617,13 @@ def compute(
|
||||
# OPT-11: the integrator does not wind past what the modes let the
|
||||
# batteries place. Only a side tighter than the rail is left in `bound`
|
||||
# (above), so this never takes SAFETY-03's `i_clamped` away from the rail.
|
||||
held_by_bound = False
|
||||
if bound is not None:
|
||||
held = max(float(bound[0]), min(float(bound[1]), i_w))
|
||||
if held != i_w:
|
||||
i_w = held
|
||||
reason = MODE_BOUND
|
||||
held_by_bound = True
|
||||
|
||||
# ⚠️ Applied EVERY cycle, frozen or not: the freeze is conditional, this
|
||||
# bound is not. It is what makes the worst-case unwind time finite and
|
||||
@@ -839,6 +844,7 @@ def compute(
|
||||
if inside != target:
|
||||
target = inside
|
||||
reason = MODE_BOUND
|
||||
held_by_bound = True
|
||||
# SAFETY-48's lead cap above may pull the integrator back toward the
|
||||
# slewed command; what is CARRIED stays inside the bound too.
|
||||
i_w = max(float(bound[0]), min(float(bound[1]), i_w))
|
||||
@@ -860,7 +866,7 @@ def compute(
|
||||
|
||||
return Decision(float(target), sat_count, frozen, reason, float(i_w),
|
||||
i_clamped, clamped, float(i_bound_w), float(want),
|
||||
float(clamped_w), refused)
|
||||
float(clamped_w), refused, held_by_bound)
|
||||
|
||||
|
||||
def maintenance_charge_floor(
|
||||
|
||||
@@ -923,24 +923,25 @@ def state_of(c, level, shadow):
|
||||
|
||||
|
||||
def build(c, *, level: str, checks: list, now: datetime | None = None,
|
||||
lang: str = "en") -> dict:
|
||||
lang: str = "en", held: bool | None = None) -> dict:
|
||||
"""The structured half of `/status`, in `lang` (UX-13 P5). Pure reads of
|
||||
the controller."""
|
||||
_LANG[0] = uitext.lang_of(lang)
|
||||
try:
|
||||
return _build(c, level=level, checks=checks, now=now)
|
||||
return _build(c, level=level, checks=checks, now=now, held=held)
|
||||
finally:
|
||||
_LANG[0] = "en"
|
||||
|
||||
|
||||
def _build(c, *, level, checks, now):
|
||||
def _build(c, *, level, checks, now, held=None):
|
||||
now = now or datetime.now(timezone.utc)
|
||||
shadow = bool(c.shadow)
|
||||
kind = state_of(c, level, shadow)
|
||||
# A red banner means every inverter is at 0 W (the status cascade), so
|
||||
# nothing is planned until it clears. Shadow mode still plans: it is
|
||||
# what the add-on would do.
|
||||
held = level == "bad" and not shadow
|
||||
# what the add-on would do. `held` False: an alarm while control runs
|
||||
# (SAFETY-87, the peak alarms).
|
||||
held = level == "bad" and not shadow and held is not False
|
||||
running = (bool(c.auto) or shadow) and not held
|
||||
settled = all(at_zero(inv) for inv in c.inverters)
|
||||
ctl = next((r for r in checks if r.get("id") == "controller"), None)
|
||||
|
||||
+233
-26
@@ -59,7 +59,8 @@ from .circulation import (
|
||||
)
|
||||
from .clamp import (
|
||||
REASON_CODE as CLAMP_REASON, ClampWatchdog,
|
||||
clamp_to_rating, is_commandable, loop_clamp_note, write_clamp_note,
|
||||
clamp_to_rating, delivery_short, is_commandable, loop_clamp_note,
|
||||
shortfall_note, write_clamp_note,
|
||||
)
|
||||
from . import freshness
|
||||
from . import homeview
|
||||
@@ -280,6 +281,11 @@ def pack_energy_of(inv):
|
||||
# ordinary load steps. At 2 s and slower this changes nothing.
|
||||
REFUSED_SPAN_S = (_ctl.SETTLE_CYCLES - 1) * _ctl.LOOP_TICK_S
|
||||
|
||||
# SAFETY-85 review: a battery another owner set is graded against the least it
|
||||
# was told over the same span as above (the plant's measured settle time), so
|
||||
# a healthy battery still settling on a new command is not short.
|
||||
SHORT_CYCLES, SHORT_SPAN_S = _ctl.SETTLE_CYCLES, REFUSED_SPAN_S
|
||||
|
||||
|
||||
def _refused_interval(sign: int) -> tuple:
|
||||
"""SAFETY-73: the (lo, hi) a refusing unit may be asked: 0 W that way."""
|
||||
@@ -936,6 +942,9 @@ class Controller:
|
||||
self._peak_alarm_block = None
|
||||
self._peak_high_since = None
|
||||
self._peak_floor_limited = False
|
||||
# SAFETY-87: the reserve alarm's hold, as SAFETY-81's above.
|
||||
self._reserve_batt_prev = None
|
||||
self._reserve_high_since = None
|
||||
self._maint_shape_suspended = False
|
||||
# OPT-11. Battery modes, off by default so an install that has not
|
||||
# turned them on behaves exactly as before (SAFETY-10 section 1). Each
|
||||
@@ -1176,6 +1185,12 @@ class Controller:
|
||||
self.loop_clamped: tuple[bool, str, bool] = (False, "", False)
|
||||
# UX-08: the numbers of a loop-side over-rating, for the notification.
|
||||
self.loop_clamp_facts: tuple = ()
|
||||
# SAFETY-85: this cycle's loop Decision, each battery's recent
|
||||
# standing commands, and how many cycles in a row a battery set by
|
||||
# another owner gave less than asked.
|
||||
self._loop_decision = None
|
||||
self._asked_hist: dict = {}
|
||||
self._short_run = 0
|
||||
self.stopping = False
|
||||
# SAFETY-61. time.monotonic() at the end of the last run_control() pass.
|
||||
self.loop_pass_mono = None
|
||||
@@ -2514,6 +2529,44 @@ class Controller:
|
||||
self._drain_waits = waits
|
||||
return floor if floor > 0.0 else None
|
||||
|
||||
def _peak_on_able(self, decision, maint_results):
|
||||
"""SAFETY-87: at N>=2, `decision` placed on the batteries that can
|
||||
still give: live, not refusing, above their own reserve. `able_w` is
|
||||
their rating plus the drain a held battery gives anyway (its
|
||||
maintenance pin). Unchanged when no battery is held back.
|
||||
DECISIONS/SAFETY-87-guard-uses-able-batteries.md."""
|
||||
if len(self.inverters) < 2:
|
||||
return decision
|
||||
floor = float(self.o.get(
|
||||
"peak_soc_floor", peakguard.PEAK_OPTION_DEFAULTS["peak_soc_floor"]))
|
||||
ok, held = peakguard.reserve_split(self.packs, floor)
|
||||
if not held:
|
||||
return decision
|
||||
live = set(self.live_units())
|
||||
able = [p for p, inv in zip(self.packs, self.inverters)
|
||||
if p in ok and inv.name in live and not (inv.refused or 0) > 0]
|
||||
if not able:
|
||||
return dataclasses.replace(decision, held=held)
|
||||
drain = sum(min(float(r.setpoint_w), i.rating_w())
|
||||
for i, r in zip(self.inverters, maint_results)
|
||||
if i.name in held and r.phase == DRAIN
|
||||
and r.owns_setpoint and (r.setpoint_w or 0.0) > 0.0)
|
||||
names = {p.name for p in able}
|
||||
return peakguard.place_on_able(
|
||||
decision, held,
|
||||
able_w=drain + sum(i.rating_w() for i in self.inverters
|
||||
if i.name in names),
|
||||
soc=min(float(p.soc) for p in able),
|
||||
soc_floor=peakguard.binding_soc_floor(able, floor))
|
||||
|
||||
def _peak_reserve(self) -> frozenset:
|
||||
"""SAFETY-87: the batteries that give nothing for the peak this
|
||||
cycle: under their reserve while the others carry a peak floor."""
|
||||
g = self.peak_guard
|
||||
if g is None or g.able_w is None or not (g.floor_w or 0.0) > 0.0:
|
||||
return frozenset()
|
||||
return frozenset(g.held)
|
||||
|
||||
def _peak_over_drain(self, claims, maint_results) -> None:
|
||||
"""SAFETY-83: at N=1 a peak floor above the drain rate outranks it.
|
||||
|
||||
@@ -2521,9 +2574,11 @@ class Controller:
|
||||
(P_PEAK), so the floor did not bind and the house imported what the
|
||||
drain left. Where the floor asks for more than the drain rate, it is
|
||||
refiled at P_MAINTENANCE and wins; nothing else changes. Safety claims
|
||||
(P_SAFETY) still outrank it. At N>=2 the `drain` floor does this.
|
||||
(P_SAFETY) still outrank it. At N>=2 the `drain` floor does this, and
|
||||
`_drain_over_reserve()` when a battery is held at its reserve.
|
||||
"""
|
||||
if len(self.inverters) != 1:
|
||||
self._drain_over_reserve(claims, maint_results)
|
||||
return
|
||||
res = maint_results[0]
|
||||
if res.phase != DRAIN or not res.owns_setpoint:
|
||||
@@ -2533,6 +2588,59 @@ class Controller:
|
||||
if c.source == peakguard.SOURCE and c.lo > rate:
|
||||
claims[i] = dataclasses.replace(c, priority=P_MAINTENANCE)
|
||||
|
||||
def _held_pin(self, claims, u):
|
||||
"""SAFETY-87: what held unit `u` places anyway (its own pin), or None
|
||||
when that pin charges, so the site is never split both ways."""
|
||||
b = pre_resolve([c for c in claims if c.actuator == u])
|
||||
p = None if b.contradiction else allocator.pin_w(b)
|
||||
return None if p is not None and p < 0.0 else max(p or 0.0, 0.0)
|
||||
|
||||
def _drain_over_reserve(self, claims, maint_results) -> None:
|
||||
"""SAFETY-87, N>=2: while a battery is held at its peak reserve, a
|
||||
draining battery that may still give is raised from its drain rate
|
||||
towards its rating for the peak floor, after the others. Otherwise
|
||||
the floor's rest lands on the held battery (its weight 0 only orders
|
||||
the split; the drain pin binds). A site stop still decides alone."""
|
||||
reserve = self._peak_reserve()
|
||||
floor = max((c.lo for c in claims if c.source == peakguard.SOURCE),
|
||||
default=0.0)
|
||||
if not reserve or not floor > 0.0 or any(
|
||||
c.kind == SET and c.actuator == ACTUATOR_SITE
|
||||
and c.priority > P_PEAK for c in claims):
|
||||
return
|
||||
live = set(self.live_units())
|
||||
drains, others = [], 0.0
|
||||
for inv, res in zip(self.inverters, maint_results):
|
||||
u = self.actuator_of("maintenance", inv)
|
||||
if u not in live:
|
||||
continue
|
||||
if inv.name in reserve:
|
||||
p = self._held_pin(claims, u)
|
||||
if p is None:
|
||||
return
|
||||
others += p
|
||||
continue
|
||||
b = pre_resolve([c for c in claims if c.actuator == u])
|
||||
if b.contradiction:
|
||||
continue
|
||||
p = allocator.pin_w(b)
|
||||
if p is not None and p < 0.0:
|
||||
return # a pack pinned to charge: never split both ways
|
||||
if res.phase == DRAIN and b.pinned_by == "maintenance" \
|
||||
and p is not None and p > 0.0:
|
||||
drains.append((u, p, allocator.hi_w(b)))
|
||||
others += allocator.hi_w(b) if p is None else p
|
||||
give = floor - others
|
||||
for u, p, hi in drains:
|
||||
if give <= 0.0:
|
||||
break
|
||||
up = max(p, min(hi, p + give))
|
||||
give -= up - p
|
||||
for i, c in enumerate(claims):
|
||||
if c.source == "maintenance" and c.kind == SET \
|
||||
and c.actuator == u:
|
||||
claims[i] = dataclasses.replace(c, value=up)
|
||||
|
||||
def _peak_over_hold(self, claims, maint_results):
|
||||
"""SAFETY-86: a peak floor outranks a maintenance HOLD (0 W).
|
||||
|
||||
@@ -2558,11 +2666,18 @@ class Controller:
|
||||
and c.priority > P_PEAK for c in claims):
|
||||
return
|
||||
live = set(self.live_units())
|
||||
reserve = self._peak_reserve() # SAFETY-87: they give nothing
|
||||
others = 0.0
|
||||
for inv in self.inverters:
|
||||
u = self.actuator_of("maintenance", inv)
|
||||
if u in hold or u not in live:
|
||||
continue
|
||||
if inv.name in reserve: # only its own pin, never both ways
|
||||
p = self._held_pin(claims, u)
|
||||
if p is None:
|
||||
return
|
||||
others += p
|
||||
continue
|
||||
b = pre_resolve([c for c in claims if c.actuator == u])
|
||||
if b.contradiction:
|
||||
continue
|
||||
@@ -4021,6 +4136,11 @@ class Controller:
|
||||
dev_min=self.site_dev_bound("dev_min"),
|
||||
dev_max=self.site_dev_bound("dev_max")),
|
||||
)
|
||||
# SAFETY-87: at N>=2 a battery at or under its own reserve gives
|
||||
# nothing for the peak, and the others carry the guard's need.
|
||||
if self.peak_guard is not None:
|
||||
self.peak_guard = self._peak_on_able(self.peak_guard,
|
||||
maint_results)
|
||||
# SITE, and peakguard.claim() says so on the object it builds. The
|
||||
# quantity is the 15-minute average OFFTAKE AT THE GRID CONNECTION,
|
||||
# which is what the capacity tariff bills; there is one quarter-hour
|
||||
@@ -4439,9 +4559,13 @@ class Controller:
|
||||
refused=self.batt_refused if len(self.inverters) == 1
|
||||
else self._site_refused(),
|
||||
probe=probe,
|
||||
# OPT-11: None unless battery modes are on, which is the law
|
||||
# exactly as it was.
|
||||
bound=self.loop_bound(claims) if self.modes_on else None,
|
||||
# OPT-11: None unless battery modes are on. SAFETY-85: or while
|
||||
# maintenance holds a battery at N>=2, so the loop does not
|
||||
# wind past what the others can give and jump when it ends.
|
||||
bound=(self.loop_bound(claims) if self.modes_on or (
|
||||
len(self.inverters) > 1
|
||||
and any(r.phase != IDLE for r in maint_results))
|
||||
else None),
|
||||
)
|
||||
if decision.frozen and self.sat_count < self.tuning.saturation_cycles:
|
||||
self.log_event(f"saturation freeze ({self.target:.0f} W vs "
|
||||
@@ -4450,6 +4574,7 @@ class Controller:
|
||||
self.sat_count = decision.sat_count
|
||||
self.i_w = decision.i_w
|
||||
self.loop_w = decision.target_w
|
||||
self._loop_decision = decision
|
||||
if len(self.inverters) == 1:
|
||||
self._refusal_update(decision, loop_prev, site_batt, probe)
|
||||
# --- TEL-10 ------------------------------------------------------
|
||||
@@ -4529,6 +4654,7 @@ class Controller:
|
||||
# de-assert when control is stopped.
|
||||
self.loop_clamped = (False, "", False)
|
||||
self.loop_clamp_facts = ()
|
||||
self._loop_decision = None
|
||||
|
||||
# SAFETY-28. A new resolution is a new tick, and the previous record is
|
||||
# stale from this line onwards. Incremented BEFORE resolve() so that the
|
||||
@@ -4553,7 +4679,8 @@ class Controller:
|
||||
_live = self.live_units()
|
||||
while True:
|
||||
resolution = resolve(claims, units=self.units, live=_live,
|
||||
weights=self.pack_weights, tick=self.alloc_tick)
|
||||
weights=self.pack_weights, tick=self.alloc_tick,
|
||||
reserve=self._peak_reserve())
|
||||
# SAFETY-73: a probe pin stands only while the resolved site target
|
||||
# asks at least PROBE_W its way. Below that a sibling would carry
|
||||
# the opposite direction (circulation), so the pin goes back to the
|
||||
@@ -4747,6 +4874,8 @@ class Controller:
|
||||
# That is the dropped-link case: the inverter holds its last command
|
||||
# FOREVER, so "not in the split" must mean zero on the wire, not
|
||||
# silence. The write is the same clamped, budgeted path as every other.
|
||||
# SAFETY-85, before the writes: the wire still holds last cycle's.
|
||||
self._loop_alarm_input(resolution)
|
||||
writes = []
|
||||
for inv in self.inverters:
|
||||
inv.target = float(resolution.shares.get(inv.name, 0.0))
|
||||
@@ -4960,6 +5089,49 @@ class Controller:
|
||||
for inv in self.inverters:
|
||||
inv.target = shadow.WIRE_W
|
||||
|
||||
def _loop_alarm_input(self, resolution) -> None:
|
||||
"""SAFETY-85. The loop's clamp counts only on a cycle the loop decided
|
||||
(a rating may cut it). A battery another owner set to discharge counts
|
||||
when it gave less than it was told for `saturation_cycles` cycles in a
|
||||
row. DECISIONS/SAFETY-85-no-false-not-keeping-up.md."""
|
||||
d = self._loop_decision
|
||||
if d is None:
|
||||
self._short_run = 0
|
||||
self._asked_hist = {}
|
||||
return
|
||||
unmet = self.allocation.unmet_w if self.allocation is not None else 0
|
||||
cut = (resolution.bound_by or "").split("(")[0]
|
||||
owns = (resolution.winner == "loop" and not d.held and not unmet
|
||||
and (resolution.target_w == d.target_w
|
||||
or cut in ("device", "supervised")))
|
||||
# Graded against the least that stood on the wire (0 W in shadow
|
||||
# mode) over SHORT_CYCLES cycles and SHORT_SPAN_S seconds.
|
||||
now, asked = self._now_mono, {}
|
||||
for inv in self.inverters:
|
||||
h = self._asked_hist.setdefault(inv.name, [])
|
||||
h.append((now, inv.standing_w()))
|
||||
while len(h) > SHORT_CYCLES and (
|
||||
now is None or h[0][0] is None
|
||||
or now - h[0][0] > SHORT_SPAN_S):
|
||||
h.pop(0)
|
||||
asked[inv.name] = min(w for _t, w in h)
|
||||
others = [inv for inv in self.inverters if not owns
|
||||
or allocator.pin_w(resolution.unit_bounds.get(inv.name))
|
||||
is not None]
|
||||
short = [(inv, asked[inv.name], inv.batt) for inv in others
|
||||
if inv.batt is not None
|
||||
and delivery_short(asked[inv.name], inv.batt,
|
||||
self.tuning.saturation_w)]
|
||||
self._short_run = self._short_run + 1 if short else 0
|
||||
if owns and self.loop_clamped[0]:
|
||||
return
|
||||
engaged = self._short_run >= self.tuning.saturation_cycles
|
||||
named = len(self.inverters) > 1
|
||||
self.loop_clamped = (engaged, shortfall_note(
|
||||
[(inv.name if named else None, a, g) for inv, a, g in short])
|
||||
if engaged else "", False)
|
||||
self.loop_clamp_facts = ()
|
||||
|
||||
async def check_output_clamp(self) -> None:
|
||||
"""SAFETY-03. Alarm whenever a clamp actually engaged this cycle.
|
||||
|
||||
@@ -5169,6 +5341,8 @@ class Controller:
|
||||
floor-limited the guard asked for NOTHING, because the pack is at or
|
||||
under the EMS floor, or its SoC could not be read.
|
||||
Nothing is being discharged for this quarter at all.
|
||||
(SAFETY-87, N>=2: or the batteries above their
|
||||
reserve give all they can and it is not enough.)
|
||||
|
||||
They cannot both be true: peakguard.decide()'s floor-limited branch
|
||||
returns before the `achievable_w` clamp that sets `saturated`.
|
||||
@@ -5189,6 +5363,10 @@ class Controller:
|
||||
"""
|
||||
g = self.peak_guard
|
||||
limited = bool(g is not None and g.floor_limited)
|
||||
if limited and (g.floor_w or 0.0) > 0.0:
|
||||
limited = self._reserve_short(g)
|
||||
else:
|
||||
self._reserve_batt_prev = self._reserve_high_since = None
|
||||
was, self._peak_floor_limited = self._peak_floor_limited, limited
|
||||
if not limited or was:
|
||||
return
|
||||
@@ -5211,13 +5389,8 @@ class Controller:
|
||||
# think the pack is AT it. `decide()` guards its own reason string the
|
||||
# same way; a f-string that formats a None here would turn the one
|
||||
# notification that matters into a traceback.
|
||||
# ⚠️ SAFETY-32. WHICH PACK STOPPED THE SITE. `g.soc_floor` is the floor
|
||||
# the decision was actually taken with, so this re-grades nothing and
|
||||
# cannot disagree with the alarm it is printed inside. At a roster of one
|
||||
# no pack is named - there is exactly one.
|
||||
_blocked = [name for name, why
|
||||
in peakguard.pack_permissions(self.packs, g.soc_floor)
|
||||
if why is not None]
|
||||
# SAFETY-32/87: which battery is at its reserve, each graded on its own
|
||||
# floor (`g.held`). At a roster of one no battery is named.
|
||||
# ⚠️ SAFETY-25's sentence (the reserve binds the peak guard only) is
|
||||
# part of messages.peak_reserve() on every branch, the unreadable-SoC
|
||||
# one included.
|
||||
@@ -5226,8 +5399,31 @@ class Controller:
|
||||
g.ceiling_w, soc_unread=g.soc is None,
|
||||
floor_unknown=(g.soc is not None
|
||||
and g.soc_floor is None),
|
||||
packs=(_blocked if len(self.inverters) > 1
|
||||
else ())).data())
|
||||
packs=(g.held if len(self.inverters) > 1
|
||||
else ()),
|
||||
others=(g.floor_w or 0.0) > 0.0).data())
|
||||
|
||||
def _reserve_short(self, g) -> bool:
|
||||
"""SAFETY-87: the batteries that can still give, at full power, miss
|
||||
the limit (`load_too_high()` on `g.able_w`), for ALARM_HOLD_S, as
|
||||
SAFETY-81 grades 'Load too high'."""
|
||||
p, batt = self._peak_proj, self.site_batt_w
|
||||
if batt is None:
|
||||
return self._peak_floor_limited
|
||||
prev, self._reserve_batt_prev = self._reserve_batt_prev, batt
|
||||
if prev is not None:
|
||||
batt = min(float(batt), float(prev))
|
||||
if not (p is not None and p.block_start is not None
|
||||
and peakguard.load_too_high(p, batt_w=batt,
|
||||
ceiling_w=g.ceiling_w,
|
||||
achievable_w=g.able_w)):
|
||||
self._reserve_high_since = None
|
||||
return False
|
||||
t = p.block_start + timedelta(seconds=float(p.elapsed_s))
|
||||
if self._reserve_high_since is None:
|
||||
self._reserve_high_since = t
|
||||
return ((t - self._reserve_high_since).total_seconds()
|
||||
>= peakguard.ALARM_HOLD_S)
|
||||
|
||||
async def check_circulating(self) -> None:
|
||||
"""SAFETY-31 + SAFETY-34. The alarm, and it must survive a restart.
|
||||
@@ -5998,8 +6194,10 @@ class Controller:
|
||||
"text": messages.row_peak_guard_waiting()})
|
||||
elif _pg.saturated:
|
||||
out.append({"ok": False, "warn": False, "id": "peak_guard",
|
||||
"runs": True,
|
||||
"text": messages.row_peak_saturated(_pg.ceiling_w)})
|
||||
elif _pg.floor_limited:
|
||||
elif _pg.floor_limited and (not (_pg.floor_w or 0.0) > 0.0
|
||||
or self._peak_floor_limited):
|
||||
# SAFETY-24. NOT ok, like saturation: in both states the money
|
||||
# is going to be spent and a human is the only actuator left. A
|
||||
# separate row from saturation because the two ask for opposite
|
||||
@@ -6025,18 +6223,17 @@ class Controller:
|
||||
# UX-08: the same three branches, and the same pack naming, as
|
||||
# check_peak_floor_limited()'s notification. The figures stay in
|
||||
# `_pg.reason`, on the log and the event list.
|
||||
_blocked = [name for name, why
|
||||
in peakguard.pack_permissions(self.packs,
|
||||
_pg.soc_floor)
|
||||
if why is not None]
|
||||
# SAFETY-87: `runs`, control goes on (status_payload()).
|
||||
out.append({"ok": False, "warn": False, "id": "peak_guard",
|
||||
"runs": True,
|
||||
"banner": messages.banner_peak_reserve(),
|
||||
"text": messages.row_peak_reserve(
|
||||
_pg.ceiling_w, soc_unread=_pg.soc is None,
|
||||
floor_unknown=(_pg.soc is not None
|
||||
and _pg.soc_floor is None),
|
||||
packs=(_blocked if len(self.inverters) > 1
|
||||
else ()))})
|
||||
packs=(_pg.held if len(self.inverters) > 1
|
||||
else ()),
|
||||
others=(_pg.floor_w or 0.0) > 0.0)})
|
||||
elif _pg.blind:
|
||||
out.append({"ok": False, "warn": True, "id": "peak_guard",
|
||||
"text": messages.row_peak_guard_blind(
|
||||
@@ -6157,7 +6354,8 @@ class Controller:
|
||||
elif _cw.active:
|
||||
# SAFETY-40: the integrator bound alone is amber, not red.
|
||||
out.append({"ok": False, "warn": True, "id": "not_keeping_up",
|
||||
"text": messages.row_not_keeping_up(_cw.bound)})
|
||||
"text": messages.row_not_keeping_up(
|
||||
_cw.bound_episodes)})
|
||||
# No over-rating in THIS episode (`bug` would be set), so any count
|
||||
# is from an earlier one: keep that software-fault evidence shown.
|
||||
if _cw.over_rating:
|
||||
@@ -6169,10 +6367,10 @@ class Controller:
|
||||
out.append({"ok": False, "warn": True, "id": "power_too_high",
|
||||
"text": messages.row_before(
|
||||
messages.T_OUTPUT_CLAMP, _cw.over_rating)})
|
||||
if _cw.bound:
|
||||
if _cw.bound_episodes:
|
||||
out.append({"ok": False, "warn": True, "id": "not_keeping_up",
|
||||
"text": messages.row_before(
|
||||
messages.T_LOOP_BOUND, _cw.bound)})
|
||||
messages.T_LOOP_BOUND, _cw.bound_episodes)})
|
||||
|
||||
for inv in self.inverters:
|
||||
if inv.last_write_ok is False:
|
||||
@@ -6359,6 +6557,11 @@ class Controller:
|
||||
def status_payload(self, lang: str = "en") -> dict:
|
||||
checks = self.checks()
|
||||
bad = [c for c in checks if not c["ok"] and not c["warn"]]
|
||||
# SAFETY-87: a red row with `runs` (the peak alarms) is an alarm while
|
||||
# control goes on, so it neither reads "Not ready" nor holds the page.
|
||||
runs = [c for c in bad if c.get("runs")]
|
||||
bad = [c for c in bad if not c.get("runs")]
|
||||
running_alarm = False
|
||||
# --- SAFETY-10, AND IT IS FIRST IN THE CASCADE -----------------------
|
||||
# "The battery is NOT being controlled" is the one sentence on this
|
||||
# page that may never be displaced by another condition. A banner that
|
||||
@@ -6411,6 +6614,9 @@ class Controller:
|
||||
level, banner = "bad", messages.banner_not_ready(bad[0])
|
||||
elif not self.auto:
|
||||
level, banner = "warn", messages.banner_stopped()
|
||||
elif runs:
|
||||
level, running_alarm = "bad", True
|
||||
banner = runs[0].get("banner") or messages.headline(runs[0]["text"])
|
||||
elif any(i.delivery_wd.tripped for i in self.inverters):
|
||||
# ⚠️ SAFETY-42, AND IT IS A `warn` BANNER RATHER THAN A `bad` ONE,
|
||||
# WHICH IS THE WHOLE "reports, does not act" DECISION IN ONE LINE.
|
||||
@@ -6532,6 +6738,7 @@ class Controller:
|
||||
decided_at=self.arb_at, cycle_at=self.cycle_at,
|
||||
now=datetime.now(timezone.utc), why=self.why_words)),
|
||||
]
|
||||
held = level == "bad" and not running_alarm
|
||||
out = {
|
||||
"banner": banner, "level": level, "rows": rows, "checks": checks,
|
||||
"hint": self.hint,
|
||||
@@ -6546,7 +6753,7 @@ class Controller:
|
||||
# fields are served alone (the page then shows the installer details).
|
||||
try:
|
||||
out.update(homeview.build(self, level=level, checks=checks,
|
||||
lang=lang))
|
||||
lang=lang, held=held))
|
||||
except Exception: # noqa: BLE001
|
||||
# Once per process at ERROR: the page polls every 3 s.
|
||||
if not getattr(self, "_home_failed", False):
|
||||
|
||||
@@ -217,7 +217,7 @@ def peak_saturated(ceiling_w, *, shadow: bool = False) -> Notice:
|
||||
|
||||
|
||||
def peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
packs=()) -> Notice:
|
||||
packs=(), others: bool = False) -> Notice:
|
||||
"""SAFETY-24/25/32: the peak guard may not draw the battery any lower.
|
||||
|
||||
The last sentence is SAFETY-25 and must stay: the reserve binds the peak
|
||||
@@ -227,7 +227,8 @@ def peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
roster means some inverter's cut-out level is missing (the peak reserve
|
||||
itself always has a value) - so the action names the cut-out level.
|
||||
Both are named by their setting labels, "Peak reserve (%)" and "Battery
|
||||
cut-out level (%)".
|
||||
cut-out level (%)". `others`: the other batteries give all they can and
|
||||
it is not enough (SAFETY-87), so the limit MAY be passed.
|
||||
"""
|
||||
if soc_unread:
|
||||
why = "The battery level cannot be read"
|
||||
@@ -241,6 +242,12 @@ def peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
why = (f"The battery of {names(packs)} is at its peak reserve" if packs
|
||||
else "The battery is at its peak reserve")
|
||||
act = "Switch off large loads, or lower the peak reserve."
|
||||
if others:
|
||||
return Notice(ID_PEAK_RESERVE, ALARM, T_PEAK_RESERVE,
|
||||
f"{why}, and the other batteries cannot keep this "
|
||||
f"15-minute period under your {watts(ceiling_w)} peak "
|
||||
f"limit alone. {act} Home use can still draw a battery "
|
||||
f"below its reserve, down to its cut-out level.")
|
||||
return Notice(ID_PEAK_RESERVE, ALARM, T_PEAK_RESERVE,
|
||||
f"{why}, so this 15-minute period will go over your "
|
||||
f"{watts(ceiling_w)} peak limit and raise this month's peak. "
|
||||
@@ -470,8 +477,9 @@ def row_peak_saturated(ceiling_w) -> str:
|
||||
|
||||
|
||||
def row_peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
packs=()) -> str:
|
||||
"""SAFETY-24/25/32. The second sentence is SAFETY-25 and must stay."""
|
||||
packs=(), others: bool = False) -> str:
|
||||
"""SAFETY-24/25/32. The last sentence is SAFETY-25 and must stay.
|
||||
`others`: as in `peak_reserve()` (SAFETY-87)."""
|
||||
if soc_unread:
|
||||
why = "Battery level cannot be read"
|
||||
elif floor_unknown:
|
||||
@@ -479,6 +487,10 @@ def row_peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
else:
|
||||
why = (f"{names(packs)} battery at its peak reserve" if packs
|
||||
else "Battery at its peak reserve")
|
||||
if others:
|
||||
return (f"{why}. The others cannot hold the {watts(ceiling_w)} peak "
|
||||
f"limit alone. Home use still draws it lower, to the cut-out "
|
||||
f"level.")
|
||||
return (f"{why}, so the {watts(ceiling_w)} peak limit will be passed. Home "
|
||||
f"use still draws the battery below it, down to the cut-out level.")
|
||||
|
||||
@@ -1014,6 +1026,9 @@ def status_samples() -> list:
|
||||
("row_peak_guard_off", AMBER, row_peak_guard_off()),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=False, floor_unknown=False, packs=["inverter-b"])),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=False, floor_unknown=False, packs=["inverter-b"],
|
||||
others=True)),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=True, floor_unknown=False)),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
@@ -1116,6 +1131,8 @@ def samples() -> list:
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False,
|
||||
packs=["inverter-b"]),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False,
|
||||
packs=["inverter-b"], others=True),
|
||||
peak_reserve(5000, soc_unread=True, floor_unknown=False),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=True),
|
||||
circulating(["inverter-a"], ["inverter-b"]),
|
||||
|
||||
@@ -397,7 +397,7 @@ function, so whichever way the owner answers, this file does not change and does
|
||||
not need re-testing. Nothing here indexes a phase.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
from dataclasses import dataclass, replace
|
||||
|
||||
from . import messages
|
||||
from .arbiter import ACTUATOR_SITE, P_PEAK, Claim
|
||||
@@ -490,11 +490,18 @@ class PeakDecision:
|
||||
# floor refused to size it. Mutually exclusive with `saturated` by
|
||||
# construction: this branch asks for nothing, so it cannot have run out of
|
||||
# inverter. `soc_floor_reason` says WHICH of the two ways it bound.
|
||||
# SAFETY-87: at N>=2 it may ask the batteries above their reserve for
|
||||
# `able_w`, all they have, when that is not enough (`place_on_able()`).
|
||||
floor_limited: bool = False
|
||||
soc: float | None = None
|
||||
soc_floor: float | None = None
|
||||
soc_floor_reason: str | None = None
|
||||
reason: str = ""
|
||||
# SAFETY-87, N>=2 only: the batteries at or under their own reserve,
|
||||
# which give nothing for the peak, and what the others can give (None
|
||||
# when they are not asked). See `place_on_able()`.
|
||||
held: tuple = ()
|
||||
able_w: float | None = None
|
||||
|
||||
def explain(self) -> str:
|
||||
"""Idle: the status row's plain words (UX-08). Engaged: `reason`, the
|
||||
@@ -733,6 +740,43 @@ def binding_soc_floor(packs, soc_floor):
|
||||
return max(floors)
|
||||
|
||||
|
||||
def reserve_split(packs, soc_floor) -> tuple[list, tuple]:
|
||||
"""SAFETY-87: `(packs the guard may spend, names of those it may not)`,
|
||||
each pack graded on its own floor by `pack_permissions()`."""
|
||||
perms = pack_permissions(packs, soc_floor)
|
||||
return ([p for p, (_n, why) in zip(packs, perms) if why is None],
|
||||
tuple(n for n, why in perms if why is not None))
|
||||
|
||||
|
||||
def place_on_able(decision, held, *, able_w, soc, soc_floor) -> PeakDecision:
|
||||
"""SAFETY-87: `decision` with the batteries in `held` (at or under their
|
||||
own reserve) giving nothing for the peak. `able_w`, `soc` and `soc_floor`
|
||||
describe the others, as `decide()`'s arguments do for the roster. A
|
||||
floor-limited decision is re-taken on them: they are asked for the need
|
||||
up to `able_w`, and it stays floor-limited only if that is not enough.
|
||||
`soc` and `soc_floor` keep the roster's verdict, as `decide()` echoed it.
|
||||
DECISIONS/SAFETY-87-guard-uses-able-batteries.md."""
|
||||
held = tuple(held)
|
||||
if not decision.floor_limited or decision.wanted_w is None \
|
||||
or discharge_permitted(soc, soc_floor) is not None:
|
||||
return replace(decision, held=held)
|
||||
wanted = float(decision.wanted_w)
|
||||
floor = min(wanted, float(able_w))
|
||||
head = (f"this 15-minute period heads for {decision.projected_w:.0f} W "
|
||||
f"against a {decision.ceiling_w:.0f} W limit "
|
||||
f"({decision.ceiling_from}), aiming at {decision.target_w:.0f} W. "
|
||||
f"At the peak reserve, so giving nothing for the peak: "
|
||||
f"{messages.names(held)}. The others are asked for {floor:+.0f} W")
|
||||
if floor >= wanted:
|
||||
return replace(decision, floor_limited=False, floor_w=floor,
|
||||
soc_floor_reason=None, held=held, able_w=float(able_w),
|
||||
reason=f"PEAK_GUARD: {head}")
|
||||
return replace(decision, floor_w=floor, held=held, able_w=float(able_w),
|
||||
reason=(f"PEAK_GUARD_FLOOR_LIMITED: {head}, all they can "
|
||||
f"give, but {wanted:+.0f} W was needed, so this "
|
||||
f"period may go over the limit"))
|
||||
|
||||
|
||||
def decide(projection, *, batt_w, cap_w, margin_w, reading, achievable_w, soc,
|
||||
soc_floor, max_hold_s=None, frozen: bool = False) -> PeakDecision:
|
||||
"""The whole guard. Pure: no clock, no I/O, no state carried between calls.
|
||||
@@ -1097,5 +1141,6 @@ def claim(decision: PeakDecision) -> Claim | None:
|
||||
return Claim.limit(SOURCE, P_PEAK, lo=float(decision.floor_w),
|
||||
reason=("blind" if decision.blind
|
||||
else "SoC floor" if decision.floor_limited
|
||||
and not decision.floor_w
|
||||
else "quarter peak"),
|
||||
actuator=ACTUATOR_SITE)
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.12.0"
|
||||
version: "0.13.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
|
||||
@@ -553,12 +553,14 @@ check("the status page flags it WHILE it is engaged - amber, since it is the "
|
||||
any(not c["ok"] and c["warn"] and c.get("id") == "not_keeping_up"
|
||||
and c["text"].startswith(messages.T_LOOP_BOUND)
|
||||
for c in ctl_r.red_snapshot))
|
||||
check("...and once clear, a warn row still says how many times it engaged, "
|
||||
"under the integrator bound's own title",
|
||||
# SAFETY-85: the row counts episodes, not cycles.
|
||||
check("...and once clear, a warn row still says how many times it happened "
|
||||
"(episodes, not cycles), under the integrator bound's own title",
|
||||
any(c["warn"] and c.get("id") == "not_keeping_up"
|
||||
and c["text"].startswith(messages.T_LOOP_BOUND)
|
||||
and messages.times(ctl_r.clamp_wd.bound) in c["text"]
|
||||
and "fine now" in c["text"] for c in ctl_r.checks()))
|
||||
and c["text"] == messages.row_before(
|
||||
messages.T_LOOP_BOUND, ctl_r.clamp_wd.bound_episodes)
|
||||
for c in ctl_r.checks())
|
||||
and 0 < ctl_r.clamp_wd.bound_episodes < ctl_r.clamp_wd.bound)
|
||||
# UX-07 item 1: the after-episode row used to say "output clamp ... engaged N
|
||||
# time(s)" for integrator-bound cycles. Each count now sits under its own name.
|
||||
check("UX-07 item 1: bound-only engagements are counted as the bound, and no "
|
||||
|
||||
@@ -108,15 +108,27 @@ A5DDDAD = {
|
||||
_claims, _undo_c = spy_claims()
|
||||
_bounds, _undo_b = spy_bounds()
|
||||
try:
|
||||
_now = rig.digests()
|
||||
_now = {k: rig.digest(rig.run(**v)[0])
|
||||
for k, v in rig.SCENARIOS.items() if k != "n2_maint"}
|
||||
_now["resolve"] = rig.digest(rig.resolve_rows())
|
||||
finally:
|
||||
_undo_b()
|
||||
# SAFETY-85: n2_maint (maintenance at N=2) is the one run with a bound.
|
||||
_bounds_m, _undo_b = spy_bounds()
|
||||
try:
|
||||
_now["n2_maint"] = rig.digest(rig.run(**rig.SCENARIOS["n2_maint"])[0])
|
||||
finally:
|
||||
_undo_c()
|
||||
_undo_b()
|
||||
# SAFETY-78 changes n2_maint ON PURPOSE: on a5dddad and 5a4cdc2 its N=2 drain
|
||||
# was refused on 392 of 540 cycles (site at 0 W); now none is. Printed on the
|
||||
# SAFETY-78 tree the same way. Every other digest is unchanged.
|
||||
# SAFETY-85 changes it again ON PURPOSE: while A's drain pin stands the loop
|
||||
# is bounded by what the batteries can place, so when A drops out at t=1655 B
|
||||
# follows the house down at once instead of unwinding 920 W too high. Was
|
||||
# cd4d9cb5b7e29ff4ab4fe65dab5106683d8a599f09323fbdee4018ad9b28fcd1.
|
||||
SAFETY78_N2_MAINT = \
|
||||
"cd4d9cb5b7e29ff4ab4fe65dab5106683d8a599f09323fbdee4018ad9b28fcd1"
|
||||
"1afcd46b1b987868b110d2b0f4a7555848c9aa4728a836d4a2ce2a2107268497"
|
||||
for k in A5DDDAD:
|
||||
print(f" {k:7} {'same' if _now[k] == A5DDDAD[k] else 'DIFFERS'} "
|
||||
f"{_now[k][:16]}")
|
||||
@@ -129,12 +141,14 @@ check("⭐ at N=1 and N=2, with the option absent and with it false, every "
|
||||
{k: v for k, v in _now.items() if k != "n2_maint"}
|
||||
== {k: v for k, v in A5DDDAD.items() if k != "n2_maint"})
|
||||
check("...and n2_maint is the SAFETY-78 digest: the N=2 drain that a5dddad "
|
||||
"refused on 392 of 540 cycles now runs (test_safety78.py)",
|
||||
"refused on 392 of 540 cycles now runs (test_safety78.py), bounded by "
|
||||
"SAFETY-85",
|
||||
_now["n2_maint"] == SAFETY78_N2_MAINT != A5DDDAD["n2_maint"])
|
||||
check("...and no cycle in those runs filed a `mode` claim or handed "
|
||||
"`compute()` a bound",
|
||||
check("...and no cycle in those runs filed a `mode` claim, and only "
|
||||
"n2_maint's (SAFETY-85: maintenance at N=2) handed `compute()` a bound",
|
||||
_claims and not any(c.source == "mode" for cl in _claims for c in cl)
|
||||
and _bounds and set(_bounds) == {None})
|
||||
and _bounds and set(_bounds) == {None}
|
||||
and any(b is not None for b in _bounds_m))
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
|
||||
@@ -67,8 +67,10 @@ for k in ED739D4:
|
||||
# SAFETY-84 changes n2_maint ON PURPOSE: on 9d5b7d1 its N=2 cheap-window
|
||||
# charge was refused on 214 of 540 cycles (site at 0 W); now none is.
|
||||
# Printed on the SAFETY-84 tree the same way (margin 0).
|
||||
# SAFETY-85: the loop is bounded while A charges (reasons change, commands
|
||||
# do not). Was 95722b262f1bcf504493d7b5babc3895799ac56cc15f5d2ccdbe7c9f04adfcbb.
|
||||
SAFETY84_N2_MAINT = \
|
||||
"95722b262f1bcf504493d7b5babc3895799ac56cc15f5d2ccdbe7c9f04adfcbb"
|
||||
"ef97ae2e13668b3e0b2d22f3f5f37835ea46cd306c2cc475c97e284f9dcc6545"
|
||||
check("⭐ at N=1 and N=2, with and without battery modes and with a "
|
||||
"maintenance charge, margin 0 is "
|
||||
"byte-identical to ed739d4 (n2_maint apart, below)",
|
||||
|
||||
@@ -109,6 +109,7 @@ import re
|
||||
import shutil
|
||||
import sys
|
||||
import tempfile
|
||||
import types
|
||||
import time
|
||||
from datetime import datetime, timedelta, timezone
|
||||
from math import inf, isinf
|
||||
@@ -2537,12 +2538,18 @@ print(f" banner ({len(_pay25['banner'])} chars): {_pay25['banner']}")
|
||||
# that is going over the ceiling.
|
||||
# UX-08: the banner is the notification's own title, and the row below keeps
|
||||
# the SAFETY-25 sentence.
|
||||
check("the Not ready banner is a short headline - the notification's title - "
|
||||
"and NOT the row repeated at the top of the page. A headline that is a "
|
||||
"paragraph is a headline nobody reads",
|
||||
# SAFETY-87: control goes on while the guard is floor-limited, so the banner
|
||||
# does not say "Not ready". This fixture also has a row that does stop control
|
||||
# (no SoC entity), which outranks it; the peak row alone is graded below.
|
||||
c25.checks = lambda: rows25
|
||||
_pay25 = c25.status_payload()
|
||||
del c25.checks
|
||||
print(f" banner, peak row alone: {_pay25['banner']}")
|
||||
check("the banner is a short headline - the notification's title, without "
|
||||
"'Not ready' (control goes on) - and NOT the row repeated at the top of "
|
||||
"the page. A headline that is a paragraph is a headline nobody reads",
|
||||
_pay25["level"] == "bad"
|
||||
and _pay25["banner"] == (f"{messages.NOT_READY} — "
|
||||
f"{messages.T_PEAK_RESERVE}")
|
||||
and _pay25["banner"] == messages.T_PEAK_RESERVE
|
||||
and not _row_scope(_pay25["banner"]))
|
||||
check("...and shortening the banner did NOT shorten the row: the SAFETY-25 "
|
||||
"sentence is still what the checks list carries, which is the surface the "
|
||||
@@ -4139,18 +4146,22 @@ check("⚠️ ...AND THE SAME PAIR SWAPPED GIVES THE SAME SITE FLOOR, so no "
|
||||
and _g_deepa.soc_floor != _g_shallow.soc_floor
|
||||
and [pk.bms_floor for pk in _g_ctl_deepa.packs]
|
||||
== [B_PACK_FLOOR_DEEP_SIM, B_PACK_FLOOR_SIM])
|
||||
check("...and it is not just a number in a report - THE SITE'S VERDICT FLIPS. "
|
||||
"With both packs at 25 % the shallow site is permitted and the guard "
|
||||
"sizes a positive forced discharge; BOTH deep sites are FLOOR-LIMITED, "
|
||||
"because 25 % is at or below the 35 % cut-out wherever on the roster it "
|
||||
"sits. Grading the roster against one position would spend a pack its "
|
||||
"BMS stops - through `sim/inject.py`, which does not run rule 8 - and "
|
||||
"this line is what goes red when it does",
|
||||
# SAFETY-87 changed what the verdict is at N>=2: the pack at or under its own
|
||||
# floor is HELD (named, gives nothing for the peak) and the others still shave.
|
||||
check("...and it is not just a number in a report - THE HELD PACK FOLLOWS IT. "
|
||||
"With both packs at 25 % the shallow site holds nobody back; on BOTH deep "
|
||||
"sites the pack whose 35 % cut-out is at or above 25 % is held, wherever "
|
||||
"it sits, gives nothing for the peak (weight 0), and the other pack "
|
||||
"carries a positive floor (SAFETY-87). Holding a position instead of "
|
||||
"the pack would spend a pack its BMS stops",
|
||||
_g_shallow.floor_limited is False and _g_shallow.floor_w > 0.0
|
||||
and _g_deep.floor_limited is True and _g_deep.floor_w == 0.0
|
||||
and _g_deep.soc_floor_reason == FLOOR_AT_SOC_FLOOR
|
||||
and _g_deepa.floor_limited is True and _g_deepa.floor_w == 0.0
|
||||
and _g_deepa.soc_floor_reason == FLOOR_AT_SOC_FLOOR)
|
||||
and _g_shallow.held == ()
|
||||
and _g_deep.floor_limited is False and _g_deep.floor_w > 0.0
|
||||
and _g_deep.held == ("inverter-b",)
|
||||
and _g_ctl_deep._peak_reserve() == {"inverter-b"}
|
||||
and _g_deepa.floor_limited is False and _g_deepa.floor_w > 0.0
|
||||
and _g_deepa.held == ("inverter-a",)
|
||||
and _g_ctl_deepa._peak_reserve() == {"inverter-a"})
|
||||
check("...and the precondition that makes the three runs comparable (habit 1): "
|
||||
"the two deep runs carry THE SAME PAIR of cut-outs in opposite orders, "
|
||||
"those two numbers really are different, and all six packs are at the "
|
||||
@@ -4221,14 +4232,14 @@ check("⚠️ THE POSITIONAL PIN, AND IT NEEDS THREE PACKS TO EXIST. On a roster
|
||||
for r in _g3_runs)
|
||||
and [[pk.bms_floor for pk in r[2].packs] for r in _g3_runs]
|
||||
== [r[1] for r in _g3_runs])
|
||||
check("...and the VERDICT flips with it, on all three: 25 % is at or below the "
|
||||
"35 % cut-out wherever it sits, so every one of these sites is "
|
||||
"FLOOR-LIMITED and sizes no forced discharge at all - where the "
|
||||
"all-shallow two-pack baseline above was permitted and sized a positive "
|
||||
"one. A slice that dropped the deep position would spend, through "
|
||||
"`sim/inject.py`, a pack its BMS stops",
|
||||
all(r[3].floor_limited is True and r[3].floor_w == 0.0
|
||||
and r[3].soc_floor_reason == FLOOR_AT_SOC_FLOOR for r in _g3_runs)
|
||||
check("...and the HELD pack follows it, on all three (SAFETY-87): 25 % is at "
|
||||
"or below the 35 % cut-out wherever it sits, so that pack and only that "
|
||||
"pack is held and gives nothing for the peak, while the two others carry "
|
||||
"a positive floor. A slice that dropped the deep position would spend, "
|
||||
"through `sim/inject.py`, a pack its BMS stops",
|
||||
all(r[3].floor_limited is False and r[3].floor_w > 0.0
|
||||
and r[3].held == (r[2].inverters[r[1].index(_G3_DEEP_SIM)].name,)
|
||||
and r[2]._peak_reserve() == set(r[3].held) for r in _g3_runs)
|
||||
and _g_shallow.floor_limited is False and _g_shallow.floor_w > 0.0)
|
||||
check("...and the precondition that makes the three comparable (habit 1): every "
|
||||
"pack in all three rosters is at the SAME state of charge, so neither the "
|
||||
@@ -4386,12 +4397,18 @@ async def _notify32(packs_socs, floors):
|
||||
inv_b, _ = second_inverter(ctl)
|
||||
for inv, so, fl in zip(ctl.inverters, packs_socs, floors):
|
||||
inv.soc, inv.bms_soc_floor = so, fl
|
||||
ctl.peak_guard = PeakDecision(
|
||||
# SAFETY-87: the full pack refuses to give (SAFETY-73), so no battery
|
||||
# can carry the peak and the alarm still fires; it names the held one.
|
||||
inv.refused = 1 if so > SOC_FLOOR else 0
|
||||
_idle = [types.SimpleNamespace(phase="idle", owns_setpoint=False,
|
||||
setpoint_w=None)] * 2
|
||||
ctl.peak_guard = ctl._peak_on_able(PeakDecision(
|
||||
engaged=True, floor_w=0.0, ceiling_w=CAP_W, ceiling_from=CEILING_CAP,
|
||||
projected_w=CAP_W + 500.0, excess_w=500.0, wanted_w=500.0,
|
||||
floor_limited=True, soc=min(packs_socs),
|
||||
soc_floor=binding_soc_floor(ctl.packs, SOC_FLOOR),
|
||||
soc_floor_reason=FLOOR_AT_SOC_FLOOR, reason="PEAK GUARD FLOOR-LIMITED: x")
|
||||
soc_floor_reason=FLOOR_AT_SOC_FLOOR, reason="PEAK GUARD FLOOR-LIMITED: x"),
|
||||
_idle)
|
||||
ctl._peak_floor_limited = False
|
||||
await ctl.check_peak_floor_limited()
|
||||
return hs.last_message("goodwe_peak_soc_floor")
|
||||
@@ -4581,18 +4598,19 @@ check("...and the TWO-pack mirror, which is what production reaches the moment "
|
||||
[r[3].soc for r in _s2_runs] == [_S_EMPTY_SIM] * 2
|
||||
and [[inv.soc for inv in r[2].inverters] for r in _s2_runs]
|
||||
== [[_S_EMPTY_SIM, _S_FULL_SIM], [_S_FULL_SIM, _S_EMPTY_SIM]])
|
||||
check("⚠️ ...AND THE SITE'S VERDICT FLIPS WITH IT, which is what makes this a "
|
||||
"defect rather than a reporting difference. With the emptiest pack at "
|
||||
"11 % - below the 20 % EMS floor - every one of those five sites is "
|
||||
"FLOOR-LIMITED and sizes NO forced discharge at all, where the baseline "
|
||||
"with its emptiest pack at 25 % is permitted and sizes a positive one. A "
|
||||
"reduction that dropped the empty pack's position would grade this site "
|
||||
"for PERMISSION against a pack 39 points fuller and spend, through "
|
||||
"`sim/inject.py`, a pack its own BMS stops",
|
||||
all(r[3].floor_limited is True and r[3].floor_w == 0.0
|
||||
# SAFETY-87: at N>=2 the emptiest pack is HELD and the others still shave.
|
||||
check("⚠️ ...AND THE HELD PACK FOLLOWS IT, which is what makes this a defect "
|
||||
"rather than a reporting difference. With the emptiest pack at 11 % - "
|
||||
"below the 20 % EMS floor - that pack and only that pack is held on "
|
||||
"every one of those five sites and gives nothing for the peak, while "
|
||||
"the fuller ones carry a positive floor (SAFETY-87); the baseline holds "
|
||||
"nobody back. A reduction that dropped the empty pack's position would "
|
||||
"spend, through `sim/inject.py`, a pack its own BMS stops",
|
||||
all(r[3].floor_limited is False and r[3].floor_w > 0.0
|
||||
and r[3].held == (r[2].inverters[r[1].index(_S_EMPTY_SIM)].name,)
|
||||
for r in _s3_runs + _s2_runs)
|
||||
and _s_ok.floor_limited is False and _s_ok.floor_w > 0.0
|
||||
and _s_ok.soc == SOC_BETWEEN)
|
||||
and _s_ok.held == () and _s_ok.soc == SOC_BETWEEN)
|
||||
check("...and the precondition that makes the six runs comparable (habit 1): "
|
||||
"every pack in every roster carries the SAME cut-out, so "
|
||||
"`binding_soc_floor()` answers the SAME site floor on all of them and the "
|
||||
@@ -5727,8 +5745,8 @@ MUT.append(("main.py grading the site against ONE roster position - "
|
||||
_g_deep.soc_floor == float(B_PACK_FLOOR_DEEP_SIM)
|
||||
and _g_deepa.soc_floor == float(B_PACK_FLOOR_DEEP_SIM)
|
||||
and _g_shallow.soc_floor == float(SOC_FLOOR)
|
||||
and _g_deep.floor_limited and _g_deepa.floor_limited
|
||||
and not _g_shallow.floor_limited,
|
||||
and _g_deep.held == ("inverter-b",)
|
||||
and _g_deepa.held == ("inverter-a",) and _g_shallow.held == (),
|
||||
"part 12g, REWRITTEN as behaviour: real two-pack cycles, the SAME "
|
||||
"pair of cut-outs carried in both orders, and both the floor "
|
||||
"reaching decide() and the site's verdict follow the ROSTER rather "
|
||||
|
||||
@@ -332,15 +332,18 @@ print("\n5. the N=1 and N=2 digests")
|
||||
# newest action-log line hashed. N=2: the same on release/1.0 35cdffe. N=1:
|
||||
# re-pinned by SAFETY-83, whose `--diff` against 35cdffe changes only cycles
|
||||
# where the peak guard asked for more than the drain (test_safety83.py).
|
||||
# SAFETY-85 re-pinned two: n1_drain_owner loses its false 'not keeping up'
|
||||
# rows (commands unchanged); n2_drain's loop is bounded while A drains
|
||||
# (reasons and the loop claim change, commands unchanged).
|
||||
PINNED = {
|
||||
"n1_drain":
|
||||
"b0f9ef44149163bc0acece537fe047871c00f0d9ea213e7a7fc8efc4ad3aa500",
|
||||
"n1_drain_modes":
|
||||
"95ab82426e23bce308db3edebe18b1ab37d956952e9f521adce37150ce87ee8a",
|
||||
"n1_drain_owner":
|
||||
"10f7f42a6a952e899d739eb10c674874215c440f41ead7a9f2408bc9b4cb9ea4",
|
||||
"607c2583c7ae4bdafb90d780b3414c62d76c430ca67798cd117d1a46f3bb40ae",
|
||||
"n2_drain":
|
||||
"055d83de0552d3a014dc73d87fdd697dde8b5933b8032f9b3a464ff0d08795fb",
|
||||
"5806a6f457b7baf8dfb44daddced502f1939c114e15b84029dbb2659be8c8b0f",
|
||||
"n2_drain_owner":
|
||||
"05750347f1829c249f99154613f068f442a59ef59f409093907f6d0add78dd4c",
|
||||
}
|
||||
|
||||
@@ -83,8 +83,11 @@ def banked(c):
|
||||
|
||||
|
||||
def alarmed(c):
|
||||
"""Did SAFETY-81's 'Load too high' alarm fire on this run?"""
|
||||
return any("PEAK_GUARD_SATURATED" in e for e in c.events)
|
||||
"""Did SAFETY-81's 'Load too high' alarm fire on this run? Its quarter
|
||||
stamp too, since ALLOCATOR rows can push its row out of the 40-row log
|
||||
(SAFETY-85)."""
|
||||
return c._peak_alarm_block is not None or any(
|
||||
"PEAK_GUARD_SATURATED" in e for e in c.events)
|
||||
|
||||
|
||||
def run(house, n=2, **kw):
|
||||
@@ -465,6 +468,10 @@ print("\n8. the N=1 and N=2 digests")
|
||||
# 2026-09-30, 480 cycles each, every claim hashed. N=1 and n2_charge_dear:
|
||||
# the same on release/1.0 9d5b7d1 (the tool copied in). N=2 in a cheap
|
||||
# window: new, the charge that 9d5b7d1 refused on every cycle.
|
||||
# SAFETY-85 re-pinned the three N=2 ones: the loop is bounded while A's
|
||||
# charge pin stands. n2_charge and _banked change only the loop's reason and
|
||||
# claim on 2 cycles; n2_charge_dear changes commands on 98 cycles, where A's
|
||||
# pin lifts (t=1800) and B no longer jumps 1390 W, and after the surplus step.
|
||||
PINNED = {
|
||||
"n1_charge":
|
||||
"0ed25c856456b97acb07a39299a8cb7b1a762c4d0005b88a0823c03057a80be5",
|
||||
@@ -473,11 +480,11 @@ PINNED = {
|
||||
"n1_charge_banked":
|
||||
"2619acdd06b04e56c000b168d64e1d044346c6ba3f929c94258d6ad8189ec609",
|
||||
"n2_charge":
|
||||
"748abe785a79084bc738c82d0d6f90b951e1cb78e9629195c0c01d3bb67b55e2",
|
||||
"b16d692128f14bcce3d87b142d290e0d6b13724289680e44a05215c9eaa24a7c",
|
||||
"n2_charge_dear":
|
||||
"c34f08b3b5b6256e68cf05030fb0c29522916dc8f57c351008f48384657966c0",
|
||||
"00a197d89a5dd1e8b3ae6a5d1af66329a4dc4850476569c5931c125fa4d9eaee",
|
||||
"n2_charge_banked":
|
||||
"fb600ee1dd3202910715c97c5809584d50c6b8b57b55aaa4dc83bcaaa97627ef",
|
||||
"a6973faea916e4c88ca1770047f94478346eeb1efa4889b154fad0747f91267f",
|
||||
}
|
||||
_now = s84.digests()
|
||||
for k in PINNED:
|
||||
@@ -485,7 +492,7 @@ for k in PINNED:
|
||||
f"{_now[k][:16]}")
|
||||
check("⭐ at N=1 a charge in and out of a cheap window and under a banked "
|
||||
"month peak is byte-identical to 9d5b7d1 (commands, reasons and every "
|
||||
"claim), and so is N=2 outside a cheap window",
|
||||
"claim), and N=2 outside a cheap window matches its SAFETY-85 pin",
|
||||
all(_now[k] == PINNED[k] for k in ("n1_charge", "n1_charge_dear",
|
||||
"n1_charge_banked",
|
||||
"n2_charge_dear")))
|
||||
|
||||
@@ -0,0 +1,450 @@
|
||||
"""Runnable check for SAFETY-85: no false 'not keeping up' while another owner
|
||||
sets the battery. `python3 test_safety85.py`
|
||||
|
||||
The loop's integrator bound fired every ~2.5 min during maintenance and under
|
||||
the peak guard, though the battery gave what it was told: the loop's own ask,
|
||||
re-seeded and pushed by a grid error it did not own, crossed its rail. Now the
|
||||
loop's clamp counts only on a cycle the loop decided, a battery another owner
|
||||
set alarms only when it gives less than told, and at N>=2 the loop is bounded
|
||||
while maintenance holds a battery. Drives the REAL Controller
|
||||
(tools/safety84_identity.py's harness). DECISIONS/SAFETY-85-no-false-not-keeping-up.md.
|
||||
|
||||
1. N=1 and N=2: a drain, a charge and a HOLD with the house above what the
|
||||
battery is set to, an hour each: no warning; without the fix they warn.
|
||||
2. A battery that gives less than told during a drain does alarm (N=1, N=2);
|
||||
a two-cycle dip does not.
|
||||
3. Control coming back from maintenance does not jump (N=2 hold end, N=2
|
||||
charge pin lifting, N=1 hold end).
|
||||
4. The loop's own alarm stays (house over the rating); a safety limit at N=2
|
||||
(a battery at its cut-out) does not warn.
|
||||
5. The status row counts episodes, not cycles.
|
||||
6. The rules at their boundaries.
|
||||
7. Review: a battery the peak guard sets that gives nothing warns; a battery
|
||||
that lags (10 s) and a charge that tapers do not.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import logging
|
||||
import os
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety79_identity as s79 # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
import app.main as app_main # noqa: E402
|
||||
from app import clamp, messages # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.store import unit_key # noqa: E402
|
||||
|
||||
fails = []
|
||||
A = "inverter-a"
|
||||
HOUR = 3600.0
|
||||
SLEW = 400.0 # the rig's slew_w
|
||||
OPT0 = dict(s84.OPT)
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
async def _call(self, *a):
|
||||
"""The rig's Home Assistant, recording each notification id it is sent."""
|
||||
if len(a) >= 3 and a[1] == "create" and isinstance(a[2], dict):
|
||||
self.__dict__.setdefault("notes", []).append(
|
||||
a[2].get("notification_id"))
|
||||
return True
|
||||
|
||||
|
||||
rig._Hass.call = _call
|
||||
|
||||
|
||||
def store(n, phase):
|
||||
"""Battery A in `phase` from the first cycle ('drain': due at 11:00;
|
||||
'idle': only with `maint=False`)."""
|
||||
if phase == "drain":
|
||||
return rig._Store()
|
||||
if phase == "charge":
|
||||
return s79.store_charging(n)
|
||||
s = rig._Store()
|
||||
if phase == "hold":
|
||||
for k, v in (("phase", "hold"), ("phase_started",
|
||||
rig.BASE.isoformat())):
|
||||
s.data[k if n == 1 else unit_key(A, k)] = v
|
||||
return s
|
||||
|
||||
|
||||
def run(n, phase, house, cap, *, dur=HOUR, soc=None, cut=None, extra=None,
|
||||
maint=True):
|
||||
"""Rows and controller; `cap` is the peak limit (20000: never binds);
|
||||
`house` is watts or a function of time."""
|
||||
s84.OPT = dict(OPT0, peak_cap_w=cap, maintenance_enabled=maint)
|
||||
if soc is None:
|
||||
def soc(u, t):
|
||||
return 99.0 if phase == "hold" and u == "a" else 60.0
|
||||
try:
|
||||
load = house if callable(house) else (lambda t: house)
|
||||
return s84.run(n, load=load, cheap=(phase == "charge"),
|
||||
store=store(n, phase), soc=soc, dur=dur, cut=cut,
|
||||
extra=dict({"maintenance_hold_min": 600,
|
||||
"maintenance_discharge_w": 2000},
|
||||
**(extra or {})))
|
||||
finally:
|
||||
s84.OPT = OPT0
|
||||
|
||||
|
||||
def warned(c):
|
||||
"""'Battery is not keeping up': notifications, cycles, episodes."""
|
||||
return (getattr(c.hass, "notes", []).count(messages.ID_LOOP_BOUND),
|
||||
c.clamp_wd.bound, c.clamp_wd.bound_episodes)
|
||||
|
||||
|
||||
def patched(obj, name, value):
|
||||
"""Run `fn` with `obj.name` replaced (the 'without the fix' runs)."""
|
||||
def wrap(fn):
|
||||
real = getattr(obj, name)
|
||||
setattr(obj, name, value)
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
setattr(obj, name, real)
|
||||
return wrap
|
||||
|
||||
|
||||
no_gate = patched(Controller, "_loop_alarm_input", lambda self, r: None)
|
||||
no_bound = patched(Controller, "loop_bound", lambda self, claims: None)
|
||||
|
||||
|
||||
def cmd(r):
|
||||
return dict(r[2])
|
||||
|
||||
|
||||
def steps(rows, lo, hi):
|
||||
"""The largest change in the total command between cycles in [lo, hi]."""
|
||||
tot = [(r[0], sum(cmd(r).values())) for r in rows]
|
||||
return max(abs(b - a) for (t0, a), (t1, b) in zip(tot, tot[1:])
|
||||
if lo <= t1 <= hi)
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. the house above what the battery is set to, an hour each")
|
||||
CASES = [
|
||||
# (n, phase, house, cap): the peak guard raises the drain / the HOLD at a
|
||||
# 3500 W limit; the rest are the phase alone under a house that pushes the
|
||||
# loop's re-seeded ask past its rail.
|
||||
(1, "drain", 6500.0, 3500), (1, "drain", 7500.0, 20000),
|
||||
(1, "charge", 10000.0, 20000),
|
||||
(1, "hold", 6500.0, 3500), (1, "hold", 9000.0, 20000),
|
||||
(2, "drain", 6500.0, 3500), (2, "charge", 10000.0, 20000),
|
||||
(2, "hold", 4500.0, 20000), (2, "hold", 6500.0, 3500),
|
||||
]
|
||||
NEW, OLD = {}, {}
|
||||
for k in CASES:
|
||||
NEW[k] = run(*k)
|
||||
OLD[k] = no_gate(lambda: no_bound(lambda: run(*k)))
|
||||
print(f" N={k[0]} {k[1]:6} house {k[2]:5.0f} limit {k[3]:5}: phases "
|
||||
f"{sorted({p for r in NEW[k][0] for p in r[-1][3]})}, warnings "
|
||||
f"(notes, cycles, episodes) {warned(NEW[k][1])}, without the fix "
|
||||
f"{warned(OLD[k][1])}")
|
||||
check("⭐ no 'Battery is not keeping up' notification, cycle or episode in any "
|
||||
"of the nine hours, at N=1 and N=2",
|
||||
all(warned(c) == (0, 0, 0) for _r, c in NEW.values()))
|
||||
check("...the phase held all hour (the battery was set by maintenance, or by "
|
||||
"the guard over it, throughout)",
|
||||
all(all(r[-1][3][0] == k[1] for r in NEW[k][0]) for k in CASES))
|
||||
check("non-vacuous: without the fix every one of the nine warns, the "
|
||||
"notification re-created on the re-assert cadence",
|
||||
all(warned(c)[0] >= 1 and warned(c)[1] > 0 for _r, c in OLD.values())
|
||||
and sum(warned(c)[0] for _r, c in OLD.values()) >= 9 * 5)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n2. a battery that really gives less than told still alarms")
|
||||
|
||||
|
||||
def gone(t0, t1):
|
||||
"""Battery A gives nothing from t0 to t1."""
|
||||
return lambda u, t: u == "a" and t0 <= t < t1
|
||||
|
||||
|
||||
SHORT = {n: run(n, "drain", 1000.0, 20000, dur=1200.0, cut=gone(600, 1200))
|
||||
for n in (1, 2)}
|
||||
for n, (rows, c) in SHORT.items():
|
||||
print(f" N={n}: {warned(c)}, log "
|
||||
f"{[e for e in c.events if 'OUTPUT_CLAMP' in e][:1]}")
|
||||
_r1, _c1 = SHORT[1]
|
||||
check("⭐ N=1, a drain of 2000 W that gives nothing: it warns, and the log "
|
||||
"says what was asked and what came",
|
||||
warned(_c1)[0] >= 1 and any(
|
||||
"the battery gives -4 W of the +2000 W asked" in e
|
||||
for e in _c1.events))
|
||||
_r2, _c2 = SHORT[2]
|
||||
check("⭐ N=2, the same on battery A while B follows the house: it warns and "
|
||||
"names inverter-a",
|
||||
warned(_c2)[0] >= 1 and any(
|
||||
"inverter-a gives -4 W of the +2000 W asked" in e
|
||||
for e in _c2.events))
|
||||
_hb = run(2, "hold", 4500.0, 20000, dur=1200.0,
|
||||
cut=lambda u, t: u == "b" and t >= 600)
|
||||
print(f" N=2 HOLD on A, B gives nothing: {warned(_hb[1])}")
|
||||
check("⭐ N=2, A in its HOLD and B, which the loop drives, gives nothing: the "
|
||||
"loop stands at what B may give, and it warns naming inverter-b",
|
||||
warned(_hb[1])[0] >= 1 and any(
|
||||
"inverter-b gives -4 W of the +2500 W asked" in e
|
||||
for e in _hb[1].events))
|
||||
check("...it starts no earlier than the saturation cycles allow (3 x 5 s)",
|
||||
all(e.split(" ", 1)[0] >= "11:10:10" for c in (_c1, _c2)
|
||||
for e in c.events if "OUTPUT_CLAMP" in e))
|
||||
_quiet = patched(app_main, "delivery_short", lambda *a: False)(
|
||||
lambda: run(1, "drain", 1000.0, 20000, dur=1200.0, cut=gone(600, 1200)))
|
||||
check("non-vacuous: without the delivery rule the N=1 drain that gives "
|
||||
"nothing is silent (the loop's clamp never reaches its rail here)",
|
||||
warned(_quiet[1]) == (0, 0, 0))
|
||||
_dip = run(1, "drain", 1000.0, 20000, dur=900.0, cut=gone(600, 610))
|
||||
check("a dip of two cycles is not an alarm", warned(_dip[1]) == (0, 0, 0))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n3. control coming back from maintenance does not jump")
|
||||
END = {"maintenance_hold_min": 10}
|
||||
_bounds = []
|
||||
_real_compute = app_main.compute
|
||||
|
||||
|
||||
def _spy_compute(*a, **kw):
|
||||
_bounds.append(kw.get("bound"))
|
||||
return _real_compute(*a, **kw)
|
||||
|
||||
|
||||
app_main.compute = _spy_compute
|
||||
try:
|
||||
_h2 = run(2, "hold", 4500.0, 20000, dur=900.0, extra=END)
|
||||
finally:
|
||||
app_main.compute = _real_compute
|
||||
_h2_old = no_bound(lambda: run(2, "hold", 4500.0, 20000, dur=900.0,
|
||||
extra=END))
|
||||
_h1 = run(1, "hold", 4500.0, 20000, dur=900.0, extra=END)
|
||||
s84.OPT = dict(OPT0)
|
||||
_cd = s84.run(2, cheap=False)
|
||||
_cd_old = no_bound(lambda: s84.run(2, cheap=False))
|
||||
print(f" N=2 hold end: largest step {steps(_h2[0], 560, 700):.0f} W "
|
||||
f"(without the bound {steps(_h2_old[0], 560, 700):.0f} W); N=1 "
|
||||
f"{steps(_h1[0], 560, 700):.0f} W; N=2 charge pin lifts at 1800 s: "
|
||||
f"{steps(_cd[0], 1780, 1840):.0f} W (without "
|
||||
f"{steps(_cd_old[0], 1780, 1840):.0f} W)")
|
||||
check("⭐ N=2, the HOLD ends under a 4500 W house: the batteries move at most "
|
||||
"one slew step a cycle",
|
||||
_h2[1].maints[0].phase != "hold" and steps(_h2[0], 560, 700) <= SLEW)
|
||||
_held = [any(p != "idle" for p in r[-1][3]) for r in _h2[0]]
|
||||
print(f" bound per cycle: {len(_bounds)} calls, {len(_held)} rows, "
|
||||
f"{sum(_held)} in maintenance, "
|
||||
f"{sum(b is not None for b in _bounds)} bounded")
|
||||
check("...and the bound is on while A holds and off from the cycle the HOLD "
|
||||
"ends (review)",
|
||||
len(_bounds) == len(_held) and any(not h for h in _held)
|
||||
and all((b is not None) == h for b, h in zip(_bounds, _held)))
|
||||
check("⭐ N=2, A's charge pin lifts at a quarter's start: at most one slew "
|
||||
"step a cycle", steps(_cd[0], 1780, 1840) <= SLEW)
|
||||
check("...and N=1 already moved one slew step at a time (re-seeded each "
|
||||
"cycle), unchanged", steps(_h1[0], 560, 700) <= SLEW)
|
||||
check("non-vacuous: without the bound the N=2 loop stands wound at its rail "
|
||||
"and both jump (2500 W at the hold's end)",
|
||||
steps(_h2_old[0], 560, 700) >= 2000.0
|
||||
and steps(_cd_old[0], 1780, 1840) >= 1000.0)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. what still warns, and what a safety limit does")
|
||||
_rail = run(1, "drain", 6500.0, 20000, dur=600.0, maint=False)
|
||||
print(f" N=1 no maintenance, house 6500 over a 5000 W rating: "
|
||||
f"{warned(_rail[1])}")
|
||||
check("⭐ the loop in charge at its rail (house over the rating) still warns, "
|
||||
"as SAFETY-40 decided", warned(_rail[1])[0] >= 1)
|
||||
|
||||
|
||||
def at_cutout(u, t):
|
||||
return 9.0 if u == "a" else 60.0
|
||||
|
||||
|
||||
_cut = run(2, "idle", 6000.0, 20000, dur=900.0, soc=at_cutout, maint=False)
|
||||
_cut_old = no_gate(lambda: run(2, "idle", 6000.0, 20000, dur=900.0,
|
||||
soc=at_cutout, maint=False))
|
||||
print(f" N=2, A at its cut-out, house 6000: {warned(_cut[1])}, without "
|
||||
f"the fix {warned(_cut_old[1])}")
|
||||
check("⭐ N=2, A at its cut-out level (a safety limit sets it to 0 W) and B "
|
||||
"at its rating: no warning, each battery gives what it is told",
|
||||
warned(_cut[1]) == (0, 0, 0) and cmd(_cut[0][-1]) == {"a": 0.0,
|
||||
"b": 2500.0})
|
||||
check("non-vacuous: without the fix it warns",
|
||||
warned(_cut_old[1])[0] >= 1)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n5. the status row counts episodes")
|
||||
_wd = clamp.ClampWatchdog()
|
||||
_t = datetime(2026, 9, 20, 11, 0, tzinfo=timezone.utc)
|
||||
for ep in range(3):
|
||||
for i in range(10):
|
||||
_wd.note(True, "x", _t, bug=False)
|
||||
_t += timedelta(seconds=5)
|
||||
for i in range(clamp.CLEAR_CYCLES):
|
||||
_wd.note(False, "", _t)
|
||||
_t += timedelta(seconds=5)
|
||||
_wd.note(True, "y", _t, bug=True)
|
||||
check("three bound episodes of ten cycles and one over-rating: 3 episodes, "
|
||||
"30 cycles", (_wd.bound_episodes, _wd.bound, _wd.episodes) == (3, 30, 4))
|
||||
_rows = [x for x in _c1.checks() if x.get("id") == "not_keeping_up"]
|
||||
check("⭐ the page row reads the episodes, not the cycles "
|
||||
f"({_c1.clamp_wd.bound_episodes} vs {_c1.clamp_wd.bound})",
|
||||
_rows and _c1.clamp_wd.bound > _c1.clamp_wd.bound_episodes >= 1
|
||||
and _rows[0]["text"].startswith(messages.T_LOOP_BOUND + ": "
|
||||
+ messages.times(
|
||||
_c1.clamp_wd.bound_episodes)))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n6. the rules at their boundaries")
|
||||
DS = [((2000, 1499, 500), True), ((2000, 1500, 500), False),
|
||||
((2000, 2600, 500), False), ((2000, -4, 500), True),
|
||||
((0, -900, 500), False), ((0, 900, 500), False),
|
||||
((-2000, -1499, 500), False), ((-2000, 600, 500), False)]
|
||||
check("delivery_short: a discharge more than the margin short; more than "
|
||||
"asked, 0 W asked, or a charge (a full pack tapers) is never short",
|
||||
all(clamp.delivery_short(*a) is want for a, want in DS))
|
||||
check("the note names each battery, asked before given",
|
||||
clamp.shortfall_note([("inverter-a", 2000.0, -4.0)])
|
||||
== "OUTPUT_CLAMP: inverter-a gives -4 W of the +2000 W asked"
|
||||
and clamp.shortfall_note([(None, -2000.0, 0.0)])
|
||||
== "OUTPUT_CLAMP: the battery gives +0 W of the -2000 W asked")
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n7. review: the peak guard, a battery that lags, a charge that tapers")
|
||||
import math # noqa: E402
|
||||
|
||||
|
||||
def under_guard(n, cut):
|
||||
"""A HOLD the peak guard raises (house 6500, limit 3500), 20 min."""
|
||||
return run(n, "hold", 6500.0, 3500, dur=1200.0, cut=cut)
|
||||
|
||||
|
||||
_g1 = under_guard(1, lambda u, t: t >= 600)
|
||||
_g2 = under_guard(2, lambda u, t: u == "a" and t >= 600)
|
||||
print(f" under the guard, the battery gives nothing: N=1 {warned(_g1[1])}, "
|
||||
f"N=2 {warned(_g2[1])}")
|
||||
check("⭐ the peak guard sets the battery and it gives nothing: it warns at "
|
||||
"N=1, and at N=2 (A, raised for the peak, gives nothing; B gives all "
|
||||
"it is told)",
|
||||
warned(_g1[1])[0] >= 1 and warned(_g2[1])[0] >= 1
|
||||
and all("peak" in r[6] for rows, _c in (_g1, _g2) for r in rows
|
||||
if 600 <= r[0] <= 620))
|
||||
check("...and it gives what it is told until then (no warning before 600 s)",
|
||||
all(e.split(" ", 1)[0] >= "11:10:00" for c in (_g1[1], _g2[1])
|
||||
for e in c.events if "OUTPUT_CLAMP" in e))
|
||||
|
||||
|
||||
def lagging(fn, lag=10.0):
|
||||
"""Run `fn` on plantsim's battery (800 W/s ramp, `lag` s first-order lag)
|
||||
at the live 2 s meter tick."""
|
||||
real_p, real_t = rig._Hass.power, rig.TICK
|
||||
|
||||
def power(self, u):
|
||||
st = self.__dict__.setdefault("_plant", {})
|
||||
a, tgt, tl = st.get(u, (0.0, 0.0, self.t))
|
||||
for _ in range(int(round((self.t - tl) / 0.1))):
|
||||
d = self.cmd[u] - tgt
|
||||
tgt += math.copysign(min(abs(d), 80.0), d)
|
||||
a += (tgt - a) * (1 - math.exp(-0.1 / lag))
|
||||
st[u] = (a, tgt, self.t)
|
||||
if self.cut(u, self.t) and self.cmd[u] >= -4.0:
|
||||
return -4.0
|
||||
return float(round(a))
|
||||
rig._Hass.power, rig.TICK = power, 2.0
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
rig._Hass.power, rig.TICK = real_p, real_t
|
||||
|
||||
|
||||
def kettle(t):
|
||||
"""800 W, plus 2 kW 3 min in 10, plus 3 kW 1 min in 4."""
|
||||
return (800.0 + (2000.0 if t % 600 < 180 else 0.0)
|
||||
+ (3000.0 if t % 240 < 60 else 0.0))
|
||||
|
||||
|
||||
def lag_runs():
|
||||
return [run(n, ph, kettle, 3500, dur=1800.0)
|
||||
for n, ph in ((1, "drain"), (2, "drain"), (2, "hold"))]
|
||||
|
||||
|
||||
_lag = lagging(lag_runs)
|
||||
_lag_old = patched(app_main, "SHORT_CYCLES", 1)(
|
||||
lambda: patched(app_main, "SHORT_SPAN_S", 0.0)(
|
||||
lambda: lagging(lag_runs)))
|
||||
_lag_dead = lagging(lambda: run(1, "drain", 1000.0, 20000, dur=900.0,
|
||||
cut=gone(600, 900)))
|
||||
print(f" lagging battery, house steps under the guard: "
|
||||
f"{[warned(c) for _r, c in _lag]}, graded on last cycle's command "
|
||||
f"{[warned(c) for _r, c in _lag_old]}; gives nothing "
|
||||
f"{warned(_lag_dead[1])}")
|
||||
check("⭐ a battery that lags (10 s) behind maintenance and peak-guard steps "
|
||||
"at a 2 s meter does not warn (N=1 drain, N=2 drain and HOLD, 30 min)",
|
||||
all(warned(c) == (0, 0, 0) for _r, c in _lag))
|
||||
check("non-vacuous: graded on last cycle's command alone, it warns",
|
||||
sum(warned(c)[0] for _r, c in _lag_old) >= 3)
|
||||
check("...and a lagging battery that gives nothing still warns",
|
||||
warned(_lag_dead[1])[0] >= 1)
|
||||
|
||||
|
||||
def taper(fn):
|
||||
"""Battery A takes the full charge until 600 s, then its acceptance falls
|
||||
to 150 W over 30 min (constant-voltage taper)."""
|
||||
real_p = rig._Hass.power
|
||||
|
||||
def power(self, u):
|
||||
c = self.cmd[u]
|
||||
if c < 0 and u == "a":
|
||||
c = max(c, -max(150.0, 2500.0 - max(0.0, self.t - 600) / 1800
|
||||
* 2350.0))
|
||||
return float(round(c))
|
||||
rig._Hass.power = power
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
rig._Hass.power = real_p
|
||||
|
||||
|
||||
def charge_runs():
|
||||
s84.OPT = dict(OPT0, peak_cap_w=20000)
|
||||
try:
|
||||
return [s84.run(n, load=lambda t: 800.0, cheap=True,
|
||||
store=s79.store_charging(n), soc=lambda u, t: 60.0,
|
||||
dur=2400.0) for n in (1, 2)]
|
||||
finally:
|
||||
s84.OPT = OPT0
|
||||
|
||||
|
||||
def both_ways(asked, given, margin):
|
||||
asked, given = float(asked), float(given)
|
||||
return asked != 0.0 and (asked - given) * math.copysign(1.0, asked) > margin
|
||||
|
||||
|
||||
_tp = taper(charge_runs)
|
||||
_tp_old = patched(app_main, "delivery_short", both_ways)(
|
||||
lambda: taper(charge_runs))
|
||||
print(f" a charge that tapers: {[warned(c) for _r, c in _tp]}, grading "
|
||||
f"charges too {[warned(c) for _r, c in _tp_old]}")
|
||||
check("⭐ a maintenance charge that tapers near full does not warn (N=1, N=2)",
|
||||
all(warned(c) == (0, 0, 0) for _r, c in _tp)
|
||||
and all("charge" in {p for r in rows for p in r[-1][3]}
|
||||
for rows, _c in _tp))
|
||||
check("non-vacuous: grading charges too, the taper warns",
|
||||
all(warned(c)[0] >= 3 for _r, c in _tp_old))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all SAFETY-85 checks passed")
|
||||
@@ -102,8 +102,11 @@ def on_aim(c, aim=AIM):
|
||||
|
||||
|
||||
def alarmed(c):
|
||||
"""Did SAFETY-81's 'Load too high' alarm fire on this run?"""
|
||||
return any("PEAK_GUARD_SATURATED" in e for e in c.events)
|
||||
"""Did SAFETY-81's 'Load too high' alarm fire on this run? Its quarter
|
||||
stamp too, since ALLOCATOR rows can push its row out of the 40-row log
|
||||
(SAFETY-85)."""
|
||||
return c._peak_alarm_block is not None or any(
|
||||
"PEAK_GUARD_SATURATED" in e for e in c.events)
|
||||
|
||||
|
||||
def refused(rows):
|
||||
@@ -231,8 +234,21 @@ def rows_logged(c, word):
|
||||
return sum(1 for e in c.events if word in e)
|
||||
|
||||
|
||||
def no_bound(fn):
|
||||
"""Run without SAFETY-85's loop bound (modes are off here)."""
|
||||
real = Controller.loop_bound
|
||||
Controller.loop_bound = lambda self, claims: None
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
Controller.loop_bound = real
|
||||
|
||||
|
||||
_nz_rows, _nz = run(noisy, 2)
|
||||
_nz_old = no_ceiling(lambda: run(noisy, 2))[1]
|
||||
# SAFETY-85's loop bound also keeps the loop inside what the batteries can
|
||||
# give, so the flood needs both the ceiling and the bound taken out.
|
||||
_nz_old = no_bound(lambda: no_ceiling(lambda: run(noisy, 2)))[1]
|
||||
_nz_nc = no_ceiling(lambda: run(noisy, 2))[1]
|
||||
print(f" noisy house: ALLOCATOR rows {rows_logged(_nz, 'ALLOCATOR')}, "
|
||||
f"clamp rows {rows_logged(_nz, 'OUTPUT_CLAMP')} (without the site "
|
||||
f"ceiling {rows_logged(_nz_old, 'ALLOCATOR')} and "
|
||||
@@ -244,9 +260,13 @@ check("⭐ while A gives, the site target is the guard's floor (the `hold` "
|
||||
if cmd(r)["a"] > 0.0)
|
||||
and rows_logged(_nz, "ALLOCATOR") == 0
|
||||
and rows_logged(_nz, "OUTPUT_CLAMP") <= 1)
|
||||
check("non-vacuous: without the ceiling the loop asks 5000 W and the "
|
||||
"ALLOCATOR and clamp rows fill the 40-row log",
|
||||
check("non-vacuous: without the ceiling and SAFETY-85's bound the loop asks "
|
||||
"5000 W and the ALLOCATOR and clamp rows fill the 40-row log",
|
||||
rows_logged(_nz_old, "ALLOCATOR") >= 10 and len(_nz_old.events) == 40)
|
||||
check("...and either one alone keeps it clean (without the ceiling: "
|
||||
f"{rows_logged(_nz_nc, 'ALLOCATOR')} ALLOCATOR rows)",
|
||||
on_aim(_nz_nc) and rows_logged(_nz_nc, "ALLOCATOR") == 0
|
||||
and rows_logged(_nz_nc, "OUTPUT_CLAMP") <= 1)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. a month peak banked above the limit")
|
||||
@@ -337,7 +357,8 @@ HOLDING = [MaintResult(HOLD, True, 0.0, False, []),
|
||||
def pin_after(floor, *extra, live=(A, B), results=HOLDING, c=_c):
|
||||
fake = types.SimpleNamespace(inverters=c.inverters,
|
||||
actuator_of=c.actuator_of,
|
||||
live_units=lambda: tuple(live))
|
||||
live_units=lambda: tuple(live),
|
||||
_peak_reserve=frozenset)
|
||||
cl = [Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=A),
|
||||
Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=B),
|
||||
Claim.set("maintenance", P_MAINTENANCE, 0.0, HOLD, actuator=A),
|
||||
|
||||
@@ -0,0 +1,709 @@
|
||||
"""Runnable check for SAFETY-87: the peak guard uses every battery that can
|
||||
still give. `python3 test_safety87.py`
|
||||
|
||||
At N>=2 the guard graded the EMPTIEST battery (SAFETY-32), so one battery under
|
||||
the peak reserve stopped the guard for all of them: it asked for nothing and
|
||||
raised the reserve alarm while the other battery was full. Now a battery at or
|
||||
under its own reserve is HELD (it gives nothing for the peak, weight 0) and
|
||||
the guard's need is placed on the others; the reserve alarm fires only when
|
||||
they cannot hold the limit. Drives the REAL Controller (tools/
|
||||
safety84_identity.py's harness). DECISIONS/SAFETY-87-guard-uses-able-batteries.md.
|
||||
|
||||
1. Maintenance charge at N=2 (A under the reserve, B able), house over the
|
||||
aim: no reserve alarm, the quarter on the aim, A gives nothing for the
|
||||
peak while B can carry it. When B cannot, the alarm fires and names A.
|
||||
2. HOLD at N=2 (A full holding, B under the reserve): A gives, B gives
|
||||
nothing, the quarter lands on the aim; at a banked month peak too.
|
||||
3. Both under the reserve, or the other one refusing: the alarm still fires
|
||||
and names the right battery.
|
||||
4. The alarm at the quarter's edge: a one-cycle miss does not fire it.
|
||||
5. place_on_able() at its boundaries, and the claim it files.
|
||||
6. The allocator: a held battery gives last, after an Off one.
|
||||
7. A held battery draining for maintenance counts for its drain.
|
||||
8. The page: a peak alarm does not say "Not ready" or "0 W until the alarm
|
||||
clears" while control goes on.
|
||||
9. N=1 is byte-identical to release/1.0 b8ddfd7 (tools/safety87_identity.py).
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import dataclasses
|
||||
import json
|
||||
import logging
|
||||
import os
|
||||
import sys
|
||||
import types
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
import safety87_identity as s87 # noqa: E402
|
||||
from app import messages, packmode, peakguard # noqa: E402
|
||||
from app.arbiter import (Claim, P_MAINTENANCE, P_MODE, P_PEAK, # noqa: E402
|
||||
P_SAFETY, UnitBounds, resolve)
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.maintenance import DRAIN, HOLD, IDLE, MaintResult # noqa: E402
|
||||
from app.store import unit_key # noqa: E402
|
||||
|
||||
fails = []
|
||||
A, B = "inverter-a", "inverter-b"
|
||||
AIM = 3450.0 # peak_cap_w 3500 - peak_margin_w 50
|
||||
TOL = 10.0 # W over the aim a banked quarter may show (SAFETY-81)
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def store(phase, *, b_off=False):
|
||||
"""Battery A in `phase` from the first cycle (B idle, cycle done)."""
|
||||
s = rig._Store()
|
||||
s.data[unit_key(A, "phase")] = phase
|
||||
s.data[unit_key(A, "phase_started")] = rig.BASE.isoformat()
|
||||
s.data[unit_key(B, "last_completed")] = rig.BASE.isoformat()
|
||||
if phase == IDLE:
|
||||
s.data[unit_key(A, "last_completed")] = rig.BASE.isoformat()
|
||||
if b_off:
|
||||
s.data[unit_key(B, packmode.USE_KEY)] = False
|
||||
return s
|
||||
|
||||
|
||||
def run(house, phase, socs, *, cheap=False, n=2, **kw):
|
||||
"""Rows, controller, the notifications raised and one record per cycle:
|
||||
(floor_limited, held, floor_w, reserve set, alarm latched)."""
|
||||
notes, seen = [], []
|
||||
real_check = Controller.check_peak_floor_limited
|
||||
|
||||
async def spy(self):
|
||||
await real_check(self)
|
||||
g = self.peak_guard
|
||||
seen.append(None if g is None else (
|
||||
g.floor_limited, g.held, g.floor_w, self._peak_reserve(),
|
||||
self._peak_floor_limited))
|
||||
|
||||
def before(c, t):
|
||||
if not getattr(c.hass, "_s87", False):
|
||||
real = c.hass.call
|
||||
|
||||
async def call(*a):
|
||||
if a[:2] == ("persistent_notification", "create"):
|
||||
notes.append(a[2])
|
||||
return await real(*a)
|
||||
c.hass.call, c.hass._s87 = call, True
|
||||
return s84.feed(cheap)(c, t)
|
||||
|
||||
kw.setdefault("dur", 2700.0)
|
||||
extra = dict({"maintenance_hold_min": 600}, **kw.pop("extra", {}))
|
||||
Controller.check_peak_floor_limited = spy
|
||||
try:
|
||||
rows, c = s84.run(
|
||||
n, load=house if callable(house) else lambda t: house,
|
||||
cheap=cheap, store=kw.pop("store", None) or store(phase),
|
||||
soc=lambda u, t: socs[u], before=before, extra=extra, **kw)
|
||||
finally:
|
||||
Controller.check_peak_floor_limited = real_check
|
||||
return rows, c, notes, seen
|
||||
|
||||
|
||||
def without_fix(fn):
|
||||
"""The shipped b8ddfd7 behaviour: no battery is ever held back."""
|
||||
real = Controller._peak_on_able
|
||||
Controller._peak_on_able = lambda self, decision, results: decision
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
Controller._peak_on_able = real
|
||||
|
||||
|
||||
def cmd(r):
|
||||
return dict(r[2])
|
||||
|
||||
|
||||
def banked(c):
|
||||
return [b.offtake_avg_w for b in c.p1.blocks]
|
||||
|
||||
|
||||
def on_aim(c, aim=AIM):
|
||||
b = banked(c)
|
||||
return len(b) >= 2 and all(aim - TOL <= v <= aim + TOL for v in b)
|
||||
|
||||
|
||||
def reserve_notes(notes):
|
||||
return [x for x in notes
|
||||
if x["notification_id"] == messages.ID_PEAK_RESERVE]
|
||||
|
||||
|
||||
def limited_events(c):
|
||||
return sum(1 for e in c.events if "PEAK_GUARD_FLOOR_LIMITED" in e)
|
||||
|
||||
|
||||
def show(tag, rows, c, notes, seen):
|
||||
a = [cmd(r)["a"] for r in rows]
|
||||
b = [cmd(r)["b"] for r in rows]
|
||||
print(f" {tag}: banked {[round(v, 1) for v in banked(c)]} W, mean A "
|
||||
f"{sum(a) / len(a):.0f} W, B {sum(b) / len(b):.0f} W, reserve "
|
||||
f"alarms {len(reserve_notes(notes))}, held "
|
||||
f"{sorted({h for s in seen if s for h in s[1]})}")
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. maintenance charge at N=2: A under the reserve, B able")
|
||||
LOW_A = {"a": 11.0, "b": 60.0}
|
||||
CH = run(4500.0, "charge", LOW_A, cheap=True)
|
||||
CH_OLD = without_fix(lambda: run(4500.0, "charge", LOW_A, cheap=True))
|
||||
show("house 4500", *CH)
|
||||
show("house 4500, before the fix", *CH_OLD)
|
||||
check("⭐ house 4500 W, B can carry the guard alone: no reserve alarm (no "
|
||||
"notification, no PEAK_GUARD_FLOOR_LIMITED line) and every quarter on "
|
||||
"the aim",
|
||||
not reserve_notes(CH[2]) and limited_events(CH[1]) == 0
|
||||
and on_aim(CH[1]))
|
||||
check("...A is held (it gives nothing for the peak) on every cycle the guard "
|
||||
"asks for power, and the guard asks for a positive floor",
|
||||
any(s and s[2] and s[2] > 0.0 for s in CH[3])
|
||||
and all(s[1] == (A,) and s[3] == {A} for s in CH[3]
|
||||
if s and s[2] and s[2] > 0.0))
|
||||
check("non-vacuous: before the fix the same run raised the reserve alarm "
|
||||
"(the SAFETY-84 rig test's check 2/3 false alarm)",
|
||||
len(reserve_notes(CH_OLD[2])) >= 1 and limited_events(CH_OLD[1]) >= 1)
|
||||
_b_carry = [r for r, s in zip(CH[0], CH[3])
|
||||
if s and s[3] == {A} and r[1] <= 2500.0 and r[1] > 0.0]
|
||||
check("...and while B can carry the site target (at most its 2500 W) A is "
|
||||
"not asked to give at all (weight 0 behind B)",
|
||||
len(_b_carry) >= 3 and all(cmd(r)["a"] <= 0.0 for r in _b_carry))
|
||||
|
||||
CH65 = run(6500.0, "charge", LOW_A, cheap=True)
|
||||
show("house 6500", *CH65)
|
||||
_n65 = reserve_notes(CH65[2])
|
||||
check("⭐ house 6500 W, B (2500 W) cannot hold the 3450 W aim alone: the "
|
||||
"reserve alarm fires and names A, the battery under its reserve, and "
|
||||
"says the others cannot hold the limit alone",
|
||||
len(_n65) >= 1
|
||||
and all("inverter-a is at its peak reserve" in x["message"]
|
||||
and "inverter-b" not in x["message"]
|
||||
and "cannot keep this 15-minute period under your 3 500 W peak "
|
||||
"limit alone" in x["message"] for x in _n65))
|
||||
check("...and while it is limited the guard still asks B for everything B "
|
||||
"has (floor 2500 W), so B is never left idle",
|
||||
any(s and s[0] and s[2] == 2500.0 for s in CH65[3])
|
||||
and all(s[2] == 2500.0 for s in CH65[3] if s and s[0]))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n2. HOLD at N=2: A full and holding, B under the reserve")
|
||||
LOW_B = {"a": 99.0, "b": 15.0}
|
||||
HD = run(5500.0, HOLD, LOW_B)
|
||||
HD_OLD = without_fix(lambda: run(5500.0, HOLD, LOW_B))
|
||||
show("house 5500", *HD)
|
||||
show("house 5500, before the fix", *HD_OLD)
|
||||
check("⭐ house 5500 W: A gives, B gives nothing, every quarter lands on the "
|
||||
"aim, no reserve alarm, and A stays in its HOLD",
|
||||
on_aim(HD[1]) and not reserve_notes(HD[2])
|
||||
and limited_events(HD[1]) == 0
|
||||
and all(cmd(r)["b"] == 0.0 for r in HD[0])
|
||||
and max(cmd(r)["a"] for r in HD[0]) > 2000.0
|
||||
and HD[1].maints[0].phase == HOLD)
|
||||
check("non-vacuous: before the fix A sat at 0 W, B (at 15 %) gave through "
|
||||
"the loop and the reserve alarm fired (SAFETY-86 rig case 7a)",
|
||||
all(cmd(r)["a"] == 0.0 for r in HD_OLD[0])
|
||||
and max(cmd(r)["b"] for r in HD_OLD[0]) > 2000.0
|
||||
and len(reserve_notes(HD_OLD[2])) >= 1)
|
||||
|
||||
HD65 = run(6500.0, HOLD, LOW_B)
|
||||
HD65_OLD = without_fix(lambda: run(6500.0, HOLD, LOW_B))
|
||||
show("house 6500", *HD65)
|
||||
show("house 6500, before the fix", *HD65_OLD)
|
||||
_n = reserve_notes(HD65[2])
|
||||
check("⭐ house 6500 W, A alone (2500 W) cannot hold the aim: A gives all it "
|
||||
"has, B still gives nothing, and the reserve alarm fires ONCE naming B",
|
||||
all(cmd(r)["b"] == 0.0 for r in HD65[0])
|
||||
and max(cmd(r)["a"] for r in HD65[0]) == 2500.0
|
||||
and len(_n) == 1 and "inverter-b is at its peak reserve" in
|
||||
_n[0]["message"] and "inverter-a" not in _n[0]["message"])
|
||||
check("...and the quarter is no worse than before the fix (4051 W in the "
|
||||
"SAFETY-86 review), with B kept at its reserve",
|
||||
max(banked(HD65[1])) <= max(banked(HD65_OLD[1])) + 1.0)
|
||||
|
||||
BK = run(6000.0, HOLD, LOW_B, month_peak=4000.0)
|
||||
show("house 6000, month peak 4000", *BK)
|
||||
check("⭐ under a banked month peak of 4000 W the aim is 3950 W (peak - "
|
||||
"margin): A gives, B nothing, every quarter on 3950 W, no alarm",
|
||||
on_aim(BK[1], 3950.0) and not reserve_notes(BK[2])
|
||||
and all(cmd(r)["b"] == 0.0 for r in BK[0]))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n3. a real loss of peak limiting still alarms")
|
||||
BOTH = run(5500.0, IDLE, {"a": 15.0, "b": 12.0})
|
||||
show("both under", *BOTH)
|
||||
_nb = reserve_notes(BOTH[2])
|
||||
check("⭐ both batteries under the reserve: the reserve alarm fires and "
|
||||
"names both, the guard asks for nothing (claim lo 0 W, 'SoC floor')",
|
||||
len(_nb) >= 1
|
||||
and all("inverter-a and inverter-b" in x["message"] for x in _nb)
|
||||
and all(not s[2] for s in BOTH[3] if s and s[0])
|
||||
and any(c[0] == "peak" and c[4] == 0.0 and c[6] == "SoC floor"
|
||||
for r in BOTH[0] for c in r[-1][0]))
|
||||
|
||||
|
||||
_ctl2 = BOTH[1]
|
||||
for _inv, _s, _r in zip(_ctl2.inverters, (15.0, 60.0), (0, 1)):
|
||||
_inv.soc, _inv.refused = _s, _r # SAFETY-73: B refuses to give
|
||||
_ref = _ctl2._peak_on_able(_lim_all := peakguard.PeakDecision(
|
||||
engaged=True, floor_w=0.0, ceiling_w=3500.0,
|
||||
ceiling_from=peakguard.CEILING_CAP, projected_w=4000.0, excess_w=550.0,
|
||||
wanted_w=2000.0, target_w=3450.0, floor_limited=True, soc=15.0,
|
||||
soc_floor=20.0, soc_floor_reason=peakguard.FLOOR_AT_SOC_FLOOR,
|
||||
reason="PEAK_GUARD_FLOOR_LIMITED: x"),
|
||||
[MaintResult(IDLE, False, None, False, [])] * 2)
|
||||
check("⭐ A under the reserve and B refusing to give (SAFETY-73): nothing can "
|
||||
"give for the peak, so it stays limited at 0 W (the alarm fires) and "
|
||||
"only A is named (test_peakguard.py part 12h drives the notification)",
|
||||
_ref.floor_limited and _ref.floor_w == 0.0 and _ref.held == (A,)
|
||||
and _ref.able_w is None and _ctl2._peak_reserve() == frozenset())
|
||||
_ctl2.inverters[1].refused = 0
|
||||
_ctl2.live_units = lambda: (A,) # B dropped from the split
|
||||
_drop = _ctl2._peak_on_able(_lim_all, [MaintResult(IDLE, False, None, False,
|
||||
[])] * 2)
|
||||
del _ctl2.live_units
|
||||
check("...and the same with B dropped (not live): nothing can give, the "
|
||||
"alarm state stands at 0 W, only A named",
|
||||
_drop.floor_limited and _drop.floor_w == 0.0 and _drop.held == (A,)
|
||||
and _drop.able_w is None)
|
||||
|
||||
|
||||
async def _notify(ctl, socs, cutouts, refused):
|
||||
"""The shipped check_peak_floor_limited() on `ctl`, its notification."""
|
||||
sent = []
|
||||
|
||||
async def call(*a):
|
||||
sent.append(a)
|
||||
return True
|
||||
for inv, so, cut, ref in zip(ctl.inverters, socs, cutouts, refused):
|
||||
inv.soc, inv.bms_soc_floor, inv.refused = so, cut, ref
|
||||
real, ctl.hass.call = ctl.hass.call, call
|
||||
ctl.peak_guard = ctl._peak_on_able(dataclasses.replace(
|
||||
_lim_all, soc=min(socs), soc_floor=peakguard.binding_soc_floor(
|
||||
ctl.packs, 20.0)), [MaintResult(IDLE, False, None, False, [])] * 2)
|
||||
ctl._peak_floor_limited = False
|
||||
try:
|
||||
await ctl.check_peak_floor_limited()
|
||||
finally:
|
||||
ctl.hass.call = real
|
||||
for inv in ctl.inverters:
|
||||
inv.bms_soc_floor, inv.refused = 10, 0
|
||||
return [a[2]["message"] for a in sent
|
||||
if a[2].get("notification_id") == messages.ID_PEAK_RESERVE]
|
||||
|
||||
|
||||
# Cut-outs A 10 % / B 35 % (simulated; rule 8 refuses it, sim/inject.py does
|
||||
# not run rule 8), A at 25 % refusing, B at 30 %. Only B is at its own floor;
|
||||
# A is above its own but under the site's highest (35 %).
|
||||
_msg = asyncio.run(_notify(_ctl2, (25.0, 30.0), (10, 35), (1, 0)))
|
||||
print(f" differing cut-outs: {_msg}")
|
||||
check("⭐ the alarm names the battery at ITS OWN floor (B, 30 % <= 35 %), not "
|
||||
"every battery under the site's highest floor (A at 25 % is above its "
|
||||
"own 20 %)",
|
||||
len(_msg) == 1 and "inverter-b is at its peak reserve" in _msg[0]
|
||||
and "inverter-a" not in _msg[0])
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. the reserve alarm at the quarter's edge")
|
||||
def spiky(t):
|
||||
"""A 5000 W house (B alone can hold the aim) with a 5 s spike to
|
||||
11000 W every 150 s, which B alone cannot."""
|
||||
return 11000.0 if t % 150 < 5 else 5000.0
|
||||
|
||||
|
||||
LOW_A_IDLE = {"a": 15.0, "b": 60.0}
|
||||
SP = run(spiky, IDLE, LOW_A_IDLE)
|
||||
_flips = sum(1 for s in SP[3] if s and s[0])
|
||||
show("spiky house", *SP)
|
||||
print(f" {_flips} cycles floor-limited (B alone short during a spike)")
|
||||
check("⭐ a 5 s spike that B alone cannot cover makes the guard limited for a "
|
||||
"cycle, and that does not fire the alarm: the miss must hold for "
|
||||
"ALARM_HOLD_S, as for 'Load too high'. No quarter goes over the aim",
|
||||
_flips >= 5 and not reserve_notes(SP[2])
|
||||
and not any(s[4] for s in SP[3] if s)
|
||||
and len(banked(SP[1])) >= 2 and max(banked(SP[1])) <= AIM)
|
||||
|
||||
|
||||
def ungated(fn):
|
||||
real = Controller._reserve_short
|
||||
Controller._reserve_short = lambda self, g: True
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
Controller._reserve_short = real
|
||||
|
||||
|
||||
_ug = ungated(lambda: run(spiky, IDLE, LOW_A_IDLE))
|
||||
check("non-vacuous: without the hold the same run raises the alarm",
|
||||
len(reserve_notes(_ug[2])) >= 1)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n5. place_on_able() at its boundaries")
|
||||
_lim = peakguard.PeakDecision(
|
||||
engaged=True, floor_w=0.0, ceiling_w=3500.0,
|
||||
ceiling_from=peakguard.CEILING_CAP, projected_w=4000.0, excess_w=550.0,
|
||||
wanted_w=2000.0, target_w=3450.0, floor_limited=True, soc=15.0,
|
||||
soc_floor=20.0, soc_floor_reason=peakguard.FLOOR_AT_SOC_FLOOR,
|
||||
reason="PEAK_GUARD_FLOOR_LIMITED: x")
|
||||
|
||||
|
||||
def place(d=_lim, held=("b",), able_w=2000.0, soc=60.0, floor=20.0):
|
||||
return peakguard.place_on_able(d, held, able_w=able_w, soc=soc,
|
||||
soc_floor=floor)
|
||||
|
||||
|
||||
_eq, _short = place(), place(able_w=1999.0)
|
||||
check("⭐ the others can give exactly the need (2000 W): not limited, floor "
|
||||
"2000 W, the claim reads 'quarter peak' (the page says 'the peak "
|
||||
"limit')",
|
||||
not _eq.floor_limited and _eq.engaged and _eq.floor_w == 2000.0
|
||||
and _eq.held == ("b",) and _eq.able_w == 2000.0
|
||||
and peakguard.claim(_eq).lo == 2000.0
|
||||
and peakguard.claim(_eq).reason == "quarter peak"
|
||||
and _eq.reason.startswith("PEAK_GUARD: "))
|
||||
check("...1 W short: limited, but the claim still asks them for all they "
|
||||
"have (1999 W), not 0 W",
|
||||
_short.floor_limited and _short.floor_w == 1999.0
|
||||
and peakguard.claim(_short).lo == 1999.0
|
||||
and peakguard.claim(_short).reason == "quarter peak"
|
||||
and _short.reason.startswith("PEAK_GUARD_FLOOR_LIMITED: "))
|
||||
check("...the others' own permission is graded: at or under their floor, or "
|
||||
"unread, nothing is asked (0 W, 'SoC floor')",
|
||||
all(place(soc=s).floor_w == 0.0 and place(soc=s).floor_limited
|
||||
and peakguard.claim(place(soc=s)).reason == "SoC floor"
|
||||
for s in (20.0, 19.0, None)))
|
||||
check("...the roster's verdict is kept as decide() echoed it (soc 15 %, "
|
||||
"floor 20 %), and a decision that was not limited is only labelled",
|
||||
_eq.soc == 15.0 and _eq.soc_floor == 20.0
|
||||
and all(place(d=d) == dataclasses.replace(d, held=("b",))
|
||||
for d in (dataclasses.replace(
|
||||
_lim, floor_limited=False, engaged=False,
|
||||
floor_w=None),
|
||||
dataclasses.replace(_lim, wanted_w=None))))
|
||||
check("...and at N=1 the floor-limited claim is unchanged: 0 W, 'SoC floor'",
|
||||
peakguard.claim(_lim).lo == 0.0
|
||||
and peakguard.claim(_lim).reason == "SoC floor")
|
||||
|
||||
|
||||
|
||||
def three(socs, cuts):
|
||||
"""`_peak_on_able()` on a stub roster of three (SIMULATED packs)."""
|
||||
names = ("x", "y", "z")
|
||||
invs = [types.SimpleNamespace(name=n, refused=0, rating_w=lambda: 2500.0)
|
||||
for n in names]
|
||||
stub = types.SimpleNamespace(
|
||||
inverters=invs, o={"peak_soc_floor": 20},
|
||||
packs=[peakguard.Pack(n, so, c) for n, so, c in zip(names, socs, cuts)],
|
||||
live_units=lambda: names)
|
||||
return Controller._peak_on_able(stub, _lim, [MaintResult(
|
||||
IDLE, False, None, False, [])] * 3)
|
||||
|
||||
|
||||
# x 25 % (cut-out 10 -> floor 20), y 40 % (cut-out 30), z 15 % (held). x and
|
||||
# y each clear their own floor, but 25 % is not above y's 30 %: the pair is
|
||||
# graded min SoC against max floor (SAFETY-32), so nothing is asked.
|
||||
_t3 = three((25.0, 40.0, 15.0), (10, 30, 10))
|
||||
_t3ok = three((35.0, 40.0, 15.0), (10, 30, 10))
|
||||
check("⭐ three batteries, z held: the two others are graded as a pair, the "
|
||||
"EMPTIEST of them (25 %) against the HIGHEST of their floors (30 %), "
|
||||
"so nothing is asked; at 35 % they are asked for the need",
|
||||
_t3.held == ("z",) and _t3.floor_limited and _t3.floor_w == 0.0
|
||||
and _t3ok.held == ("z",) and not _t3ok.floor_limited
|
||||
and _t3ok.floor_w == 2000.0)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n6. the allocator: a held battery gives last")
|
||||
|
||||
|
||||
def split(target, reserve, modes=(), floor=1500.0):
|
||||
cl = [Claim.set("loop", 10, target),
|
||||
Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=A),
|
||||
Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=B),
|
||||
Claim.limit("peak", P_PEAK, lo=min(target, floor))]
|
||||
cl += [Claim.limit("mode", P_MODE, 0.0, 0.0, "off", actuator=u)
|
||||
for u in modes]
|
||||
r = resolve(cl, units=(A, B), live=(A, B), weights={A: 1.0, B: 3.0},
|
||||
reserve=reserve)
|
||||
return {u: round(v) for u, v in r.shares.items()}
|
||||
|
||||
|
||||
check("⭐ B held: A carries the site target first (B's weight 3.0 ignored) "
|
||||
"and B only takes what A cannot: 1500 -> A 1500 / B 0, 4000 -> A 2500 "
|
||||
"/ B 1500",
|
||||
split(1500.0, {B}) == {A: 1500, B: 0}
|
||||
and split(4000.0, {B}) == {A: 2500, B: 1500})
|
||||
check("...no one held: the weights decide, as before",
|
||||
split(1500.0, set()) == {A: 375, B: 1125})
|
||||
check("...charging is not touched: a held battery may still charge first",
|
||||
split(-2000.0, {B}) == split(-2000.0, set()))
|
||||
check("⭐ A Off and B under the reserve, a 3000 W floor B cannot place: the "
|
||||
"Off battery gives first (2500 W) and B only the last 500 W - not an "
|
||||
"equal 1500/1500 split",
|
||||
split(3000.0, {B}, modes=(A,), floor=3000.0) == {A: 2500, B: 500})
|
||||
check("...OPEN, recorded: when B alone CAN place the floor, OPT-11 keeps the "
|
||||
"Off battery resting and B gives it (1500 W). See the DECISIONS entry",
|
||||
split(1500.0, {B}, modes=(A,)) == {A: 0, B: 1500})
|
||||
check("...and with B Off and nobody held, Off still gives way to the other "
|
||||
"battery, as before (OPT-11)",
|
||||
split(1500.0, set(), modes=(B,)) == {A: 1500, B: 0})
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n7. a held battery draining for maintenance")
|
||||
_ctl = HD[1]
|
||||
|
||||
|
||||
def able_w(results, socs=(15.0, 60.0)):
|
||||
for inv, s in zip(_ctl.inverters, socs):
|
||||
inv.soc, inv.refused = s, 0
|
||||
d = _ctl._peak_on_able(dataclasses.replace(
|
||||
_lim, wanted_w=6000.0), results)
|
||||
return d.able_w, d.held, d.floor_w
|
||||
|
||||
|
||||
_idle = [MaintResult(IDLE, False, None, False, [])] * 2
|
||||
_drain = [MaintResult(DRAIN, True, 2000.0, False, []),
|
||||
MaintResult(IDLE, False, None, False, [])]
|
||||
print(f" A at 15 % idle: {able_w(_idle)}; draining 2000 W: "
|
||||
f"{able_w(_drain)}")
|
||||
check("⭐ A under the reserve but draining 2000 W for its monthly cycle: "
|
||||
"that drain still counts (able 4500 W = B 2500 + 2000), so B is not "
|
||||
"asked to carry it; idle, only B's 2500 W",
|
||||
able_w(_idle) == (2500.0, (A,), 2500.0)
|
||||
and able_w(_drain) == (4500.0, (A,), 4500.0))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n8. the page while a peak alarm stands and control goes on")
|
||||
_rows65, _c65 = CH65[0], CH65[1]
|
||||
_c65._peak_floor_limited = True
|
||||
_c65.peak_guard = dataclasses.replace(
|
||||
_lim, floor_w=2500.0, held=(A,), able_w=2500.0)
|
||||
_pay = _c65.status_payload()
|
||||
_txt = json.dumps(_pay, ensure_ascii=False)
|
||||
_row = [r for r in _pay["checks"] if r.get("id") == "peak_guard"]
|
||||
print(f" banner: {_pay['banner']}; row: {_row[0]['text'] if _row else '-'}")
|
||||
check("⭐ the banner is the alarm's title without 'Not ready', and nothing "
|
||||
"on the page says the inverters go to 0 W or that an alarm stopped "
|
||||
"control",
|
||||
_pay["banner"] == messages.T_PEAK_RESERVE and _pay["level"] == "bad"
|
||||
and "Not ready" not in _txt and "until the alarm clears" not in _txt
|
||||
and "An alarm stopped control" not in _txt)
|
||||
check("...the row names A and says the others cannot hold the limit alone, "
|
||||
"in three short sentences",
|
||||
len(_row) == 1 and _row[0]["text"].startswith(
|
||||
"inverter-a battery at its peak reserve. The others cannot hold "
|
||||
"the 3 500 W peak limit alone."))
|
||||
_c65._peak_floor_limited = False
|
||||
_blip = [r for r in _c65.checks() if r.get("id") == "peak_guard"]
|
||||
_c65._peak_floor_limited = True
|
||||
check("...and while the alarm is not latched (a one-cycle miss) the row is "
|
||||
"the ordinary amber guard row, not the red reserve row",
|
||||
len(_blip) == 1 and _blip[0]["warn"] and not _blip[0].get("runs")
|
||||
and "peak reserve" not in _blip[0]["text"])
|
||||
_c65.auto = False
|
||||
_stopped = _c65.status_payload()
|
||||
_c65.auto = True
|
||||
check("...a stopped controller still says so: the peak alarm does not take "
|
||||
"the banner from it", _stopped["banner"] != messages.T_PEAK_RESERVE
|
||||
and _stopped["level"] != "bad")
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n9. N=1 is byte-identical to release/1.0 b8ddfd7")
|
||||
PINNED = { # tools/safety87_identity.py on b8ddfd7
|
||||
"n1_under":
|
||||
"d2395ef8d74fb23607ad864d5a4bf62c03044bbd9367e873675d7ad10e8c169f",
|
||||
"n1_crossing":
|
||||
"97f7321017d9d34ee17a40dfd4abf73d915f25b9faef086a483d2b5cd124b198",
|
||||
"n1_above":
|
||||
"45726a285aa84f40542d56482652397c3c1e212ba4fe2009f6cc52f537ccad52",
|
||||
"n1_under_banked":
|
||||
"a2876c7cc873bc4c974d2b4bd98e23bba2d007b84545587d2fe0b713b0a6249b",
|
||||
"n1_charge_low":
|
||||
"91336e3c0314985a3b00f314c79b5ffb5a740d218de3ad44f88a4db6e4235b32",
|
||||
"n1_hold":
|
||||
"0a1df347754c69166b20d04c15ee878bbcefb02abb824b9b452334f68f03e46d",
|
||||
}
|
||||
_now = s87.digests()
|
||||
for k in PINNED:
|
||||
print(f" {k} {'same' if _now[k] == PINNED[k] else 'DIFFERS'}")
|
||||
check("⭐ every N=1 digest (claims, commands, the guard's decision and the "
|
||||
"log) equals b8ddfd7's, under, crossing and above the reserve, in a "
|
||||
"charge and a HOLD, and under a banked peak",
|
||||
_now == PINNED)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n10. review: maintenance pins beside a held battery, N=3, the page")
|
||||
|
||||
|
||||
def _drain_store():
|
||||
s = rig._Store()
|
||||
s.data[unit_key(B, "phase")] = DRAIN
|
||||
s.data[unit_key(B, "phase_started")] = rig.BASE.isoformat()
|
||||
s.data[unit_key(A, "last_completed")] = rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
def _drain_run():
|
||||
return run(8000.0, IDLE, {"a": 15.0, "b": 60.0}, store=_drain_store(),
|
||||
dur=900.0)
|
||||
|
||||
|
||||
DR = _drain_run()
|
||||
_real_dor = Controller._drain_over_reserve
|
||||
Controller._drain_over_reserve = lambda self, claims, results: None
|
||||
try:
|
||||
DR_OLD = _drain_run()
|
||||
finally:
|
||||
Controller._drain_over_reserve = _real_dor
|
||||
|
||||
|
||||
def _a_for_peak(rows):
|
||||
"""A's command on the cycles where the site target is the peak floor
|
||||
and B alone (2500 W) could place it."""
|
||||
return [cmd(r)["a"] for r in rows
|
||||
if r[-1][1] and r[-1][1][1] and r[1] <= 2500.0
|
||||
and abs(r[1] - r[-1][1][1]) < 1.0]
|
||||
|
||||
|
||||
print(f" B draining, A held: A for the peak {_a_for_peak(DR[0])[:4]}, "
|
||||
f"without the raise {_a_for_peak(DR_OLD[0])[:4]}")
|
||||
check("⭐ B draining (2000 W pin) while A is held: B is raised to its rating "
|
||||
"for the peak floor, so A gives nothing for it (peak > drain)",
|
||||
DR[1].maints[1].phase == DRAIN and _a_for_peak(DR[0])
|
||||
and all(a <= 0.0 for a in _a_for_peak(DR[0])))
|
||||
check("non-vacuous: without the raise A gave the floor's rest above B's pin",
|
||||
any(a > 0.0 for a in _a_for_peak(DR_OLD[0])))
|
||||
|
||||
|
||||
def _stub(names, reserve, live=None):
|
||||
"""A Controller stand-in for the pin rules, on SIMULATED units."""
|
||||
s = types.SimpleNamespace(
|
||||
inverters=[types.SimpleNamespace(name=n) for n in names],
|
||||
actuator_of=lambda src, inv=None: inv.name,
|
||||
live_units=lambda: tuple(live or names),
|
||||
_peak_reserve=lambda: frozenset(reserve))
|
||||
s._held_pin = lambda cl, u: Controller._held_pin(s, cl, u)
|
||||
return s
|
||||
|
||||
|
||||
def _hold(floor, names, reserve, extra=(), results=None):
|
||||
"""`_peak_over_hold()`: x HOLDs; returns (x's pin, resolved shares)."""
|
||||
s = _stub(names, reserve)
|
||||
cl = [Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=n)
|
||||
for n in names]
|
||||
cl += [Claim.set("maintenance", P_MAINTENANCE, 0.0, HOLD, actuator="x"),
|
||||
Claim.limit("peak", P_PEAK, lo=floor, reason="quarter peak"),
|
||||
*extra]
|
||||
res = results or ([MaintResult(HOLD, True, 0.0, False, [])]
|
||||
+ [MaintResult(IDLE, False, None, False, [])]
|
||||
* (len(names) - 1))
|
||||
hi = Controller._peak_over_hold(s, cl, res)
|
||||
if hi is not None:
|
||||
cl.append(Claim.limit("hold", P_MAINTENANCE, hi=hi))
|
||||
r = resolve(cl + [Claim.set("loop", 10, floor)], units=tuple(names),
|
||||
live=set(names), reserve=reserve)
|
||||
pin = next((c.value for c in cl
|
||||
if c.source == "maintenance" and c.actuator == "x"), None)
|
||||
return pin, {u: round(v) for u, v in r.shares.items()}
|
||||
|
||||
|
||||
_h3 = _hold(3000.0, ("x", "y", "z"), {"z"})
|
||||
_h3b = _hold(2000.0, ("x", "y", "z"), {"z"})
|
||||
print(f" N=3 HOLD x, y able, z held: floor 3000 {_h3}, 2000 {_h3b}")
|
||||
check("⭐ HOLD at N=3 with one held: the able battery gives first, the "
|
||||
"holding one the rest (3000 -> y 2500, x 500), the held one nothing",
|
||||
_h3 == (500.0, {"x": 500, "y": 2500, "z": 0})
|
||||
and _h3b == (0.0, {"x": 0, "y": 2000, "z": 0}))
|
||||
_hd = _hold(2000.0, ("x", "z"), {"z"},
|
||||
(Claim.set("maintenance", P_MAINTENANCE, 1500.0, DRAIN,
|
||||
actuator="z"),),
|
||||
[MaintResult(HOLD, True, 0.0, False, []),
|
||||
MaintResult(DRAIN, True, 1500.0, False, [])])
|
||||
_hp = _hold(2000.0, ("x", "z"), {"z"},
|
||||
(Claim.set("refused", P_SAFETY, -50.0, "probe", actuator="z"),))
|
||||
print(f" held z draining 1500: {_hd}; held z charge probe: {_hp}")
|
||||
check("⭐ a held battery's own pin counts: draining 1500 W, the hold gives "
|
||||
"only the 500 W rest (no over-placement); a charge probe leaves the "
|
||||
"hold at 0 W (never split both ways, no park)",
|
||||
_hd == (500.0, {"x": 500, "z": 1500}) and _hp[0] == 0.0)
|
||||
|
||||
_unk = three((60.0, 60.0, 60.0), (10, None, 10))
|
||||
_unr = three((60.0, None, 60.0), (10, 10, 10))
|
||||
check("⭐ N=3: an unknown cut-out or an unread level holds that battery "
|
||||
"only; the two others are asked for the need",
|
||||
_unk.held == ("y",) and not _unk.floor_limited
|
||||
and _unk.floor_w == 2000.0 and _unr.held == ("y",)
|
||||
and not _unr.floor_limited and _unr.floor_w == 2000.0)
|
||||
|
||||
_stop_row = {"ok": False, "warn": False, "id": "meter", "text": "Meter down."}
|
||||
_peak_rows = [r for r in _c65.checks() if r.get("id") == "peak_guard"]
|
||||
_c65.checks = lambda: _peak_rows[:1] + [_stop_row]
|
||||
_both = _c65.status_payload()
|
||||
del _c65.checks
|
||||
check("⭐ a row that stops control outranks the running peak alarm: the "
|
||||
"banner says 'Not ready' for it and the Home page shows the hold",
|
||||
len(_peak_rows) == 1 and _peak_rows[0].get("runs")
|
||||
and _both["banner"].startswith(messages.NOT_READY)
|
||||
and "Meter down" in _both["banner"]
|
||||
and "until the alarm clears" in json.dumps(_both, ensure_ascii=False))
|
||||
|
||||
for _inv, _s, _r in zip(_ctl2.inverters, (15.0, 60.0), (0, -1)):
|
||||
_inv.soc, _inv.refused = _s, _r # B refuses only to CHARGE
|
||||
_chg = _ctl2._peak_on_able(_lim_all, [MaintResult(IDLE, False, None, False,
|
||||
[])] * 2)
|
||||
_ctl2.inverters[1].refused = 0
|
||||
check("⭐ a battery that refuses only to charge can still give: it stays "
|
||||
"able and carries the floor (2000 W of 2500 W)",
|
||||
not _chg.floor_limited and _chg.floor_w == 2000.0
|
||||
and _chg.able_w == 2500.0 and _chg.held == (A,))
|
||||
|
||||
|
||||
def _short_for(held_w, secs=30.0):
|
||||
"""`_reserve_short()` over `secs` of a steady quarter: the meter at
|
||||
`held_w` with the able batteries already at their full 2500 W."""
|
||||
s = types.SimpleNamespace(_reserve_batt_prev=None,
|
||||
_reserve_high_since=None,
|
||||
_peak_floor_limited=False, site_batt_w=2500.0)
|
||||
g = dataclasses.replace(_lim, floor_w=2500.0, able_w=2500.0)
|
||||
out = []
|
||||
for k in range(int(secs / 5.0) + 1):
|
||||
s._peak_proj = types.SimpleNamespace(
|
||||
block_start=rig.BASE, elapsed_s=450.0 + 5.0 * k,
|
||||
projected_w=held_w, held_w=held_w)
|
||||
out.append(Controller._reserve_short(s, g))
|
||||
return out
|
||||
|
||||
|
||||
_aim_miss, _limit_miss = _short_for(3480.0), _short_for(3600.0)
|
||||
check("⭐ the reserve alarm is graded on the real limit, not the aim: a "
|
||||
"quarter ending at 3480 W (over the 3450 W aim, under 3500 W) never "
|
||||
"alarms; one ending at 3600 W alarms once it holds ALARM_HOLD_S",
|
||||
not any(_aim_miss) and not any(_limit_miss[:2])
|
||||
and all(_limit_miss[2:]))
|
||||
|
||||
_runs_src = {}
|
||||
for _f in ("main.py", "homeview.py"):
|
||||
with open(os.path.join(HERE, "app", _f), encoding="utf-8") as _fh:
|
||||
_src = _fh.read()
|
||||
for _part in _src.split('out.append({')[1:]:
|
||||
if '"runs": True' in _part.split("})", 1)[0]:
|
||||
_runs_src.setdefault(_f, []).append(
|
||||
_part.split('"id": "', 1)[-1].split('"', 1)[0])
|
||||
check("⭐ 'control still runs' is set on the two peak rows only (saturated "
|
||||
"and reserve); no row that stops control carries it",
|
||||
_runs_src == {"main.py": ["peak_guard", "peak_guard"]})
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all SAFETY-87 checks passed")
|
||||
@@ -0,0 +1,66 @@
|
||||
#!/usr/bin/env python3
|
||||
"""SAFETY-87: at one inverter, is the peak guard byte-identical to before?
|
||||
|
||||
python3 tools/safety87_identity.py # prints one digest per scenario
|
||||
|
||||
safety84_identity's harness (the REAL Controller on a P1 meter, every claim
|
||||
and the guard's decision hashed) with the battery under, crossing and above
|
||||
the peak reserve, the house over the aim, in a maintenance charge and HOLD,
|
||||
and under a month peak banked at 4000 W. Uses only the API release/1.0
|
||||
b8ddfd7 has, so the same file runs on both trees; test_safety87.py holds this
|
||||
tree to the digests printed there.
|
||||
"""
|
||||
|
||||
import os
|
||||
import sys
|
||||
from datetime import timedelta
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.abspath(__file__)))
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
|
||||
DUR = 1800.0
|
||||
|
||||
|
||||
def crossing(u, t):
|
||||
"""30 % falling 1 % a minute to 12 %: crosses the 20 % reserve."""
|
||||
return max(12.0, 30.0 - t / 60.0)
|
||||
|
||||
|
||||
def store(phase=None):
|
||||
"""In `phase` from the first cycle, or idle with a cycle done yesterday."""
|
||||
s = rig._Store()
|
||||
if phase is None:
|
||||
s.data["last_completed"] = (rig.BASE - timedelta(days=1)).isoformat()
|
||||
else:
|
||||
s.data["phase"], s.data["phase_started"] = phase, rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
SCENARIOS = {
|
||||
"n1_under": dict(soc=lambda u, t: 15.0, load=lambda t: 5500.0),
|
||||
"n1_crossing": dict(soc=crossing, load=lambda t: 5000.0),
|
||||
"n1_above": dict(soc=lambda u, t: 60.0, load=lambda t: 5500.0),
|
||||
"n1_under_banked": dict(soc=lambda u, t: 15.0, load=lambda t: 6000.0,
|
||||
month_peak=4000.0),
|
||||
"n1_charge_low": dict(soc=lambda u, t: 11.0, load=lambda t: 5000.0,
|
||||
store="charge"),
|
||||
"n1_hold": dict(soc=lambda u, t: 99.0, load=lambda t: 5500.0,
|
||||
store="hold", cheap=False,
|
||||
extra={"maintenance_hold_min": 600}),
|
||||
}
|
||||
|
||||
|
||||
def digests() -> dict:
|
||||
out = {}
|
||||
for k, v in SCENARIOS.items():
|
||||
v = dict(v)
|
||||
st = store(v.pop("store", None))
|
||||
out[k] = s84.digest(s84.run(1, dur=DUR, store=st, **v)[0])
|
||||
return out
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
for k, v in digests().items():
|
||||
print(f"{k} {v}")
|
||||
Reference in New Issue
Block a user