Compare commits
14
Commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
e36565fe39 | ||
|
|
808ec04dc4 | ||
|
|
35432ce065 | ||
|
|
580c200527 | ||
|
|
35b2a699de | ||
|
|
cd1bf2a694 | ||
|
|
db9e2315d1 | ||
|
|
848140c29f | ||
|
|
d12228d986 | ||
|
|
bf3ac7998c | ||
|
|
61a61941bb | ||
|
|
ef35f4b925 | ||
|
|
f39e52efd3 | ||
|
|
8a17711f60 |
@@ -1,5 +1,49 @@
|
||||
# Changelog
|
||||
|
||||
## 0.17.0
|
||||
|
||||
**A minor bump: changed behaviour, and no option changes.** No option was
|
||||
added, removed or renamed, and no default changed (83 options). Options you
|
||||
saved work as before. The changes below apply with one inverter or two, unless
|
||||
a line says "Two inverters".
|
||||
|
||||
**Maintenance with no battery level.** When the battery level is missing,
|
||||
battery maintenance now ends on its own time limits instead of waiting for the
|
||||
level to come back (MAINT-14, MAINT-15). You do not need to change any option.
|
||||
|
||||
Contents of this release, in merge order since 0.16.0 (`451729c`):
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `b527e99` | Two inverters: after a drain ends, the other battery no longer swings on old readings. In the test, it held steady for 23 s where 0.16.0 moved it by 720 W ([[SAFETY-103]]) |
|
||||
| `8a17711` | A full battery that stops at 98 or 99 % no longer counts as a failed charge. After 60 min with no new high, the charge counts as done; a charge that truly fails now waits 7 days and shows one notice ([[MAINT-13]]) |
|
||||
| `bf3ac79` | With no battery level, a maintenance charge still ends at its time limit and a drain waits at 0 W. The log no longer repeats a line every second ([[MAINT-14]]) |
|
||||
| `db9e231` | One inverter: when maintenance charges a battery that is already full, the log no longer repeats "The battery refuses to give power" every second. In the test, 1 line in 16 min where the code before this fix wrote about 1,700 in 15 min; the power does not change ([[SAFETY-107]]) |
|
||||
| `580c200` | The balancing hold after a charge now ends on time when the battery level is missing. Before, it waited until the level came back ([[MAINT-15]]) |
|
||||
|
||||
### Known issues
|
||||
|
||||
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
|
||||
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
|
||||
- A battery whose reading at rest is beyond about ±175 W is still not caught when it refuses ([[SAFETY-97]]).
|
||||
- The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s ([[SAFETY-99]]).
|
||||
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
|
||||
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
|
||||
- Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]).
|
||||
- Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]).
|
||||
- Two inverters: when a battery drops out during a solar surplus, the others can swing by up to 1.5 kW in a simulation ([[SAFETY-105]]).
|
||||
- Two inverters: after a drain ends, a change in house use can go unanswered for about 9 s, because some readings are old ([[SAFETY-106]]).
|
||||
- Two inverters: when one battery's level is missing, both batteries are held at 0 W, and for about 15 s the last command stays on ([[SAFETY-108]]).
|
||||
- Two inverters: if one battery's level stays missing for 12 h, the other battery's cycle can be marked failed, with a 7-day wait and a notice, though it is healthy. This comes from reading the code; it has not been seen on a site ([[MAINT-17]]).
|
||||
- One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]).
|
||||
|
||||
### If you are crossing from a version older than 0.10.0
|
||||
|
||||
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
|
||||
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
|
||||
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
|
||||
bare options (`jq '.data.options'`) first.
|
||||
|
||||
## 0.16.0
|
||||
|
||||
**A minor bump: changed behaviour, no option added or removed, and one default
|
||||
|
||||
@@ -0,0 +1,68 @@
|
||||
# MAINT-14 - no SoC reading in a maintenance cycle
|
||||
|
||||
**Status: for review.** Tests: `test_maint14.py`. No option added; the one new
|
||||
number is a constant in `app/maintenance.py`.
|
||||
|
||||
**The fault.** `Maintenance.tick()` returned early when the SoC was `None`,
|
||||
before any timeout check. (1) A charge on a pack whose SoC reading was lost
|
||||
never ended: no timeout, no back-off, no notice, and the 7-day backstop of
|
||||
MAINT-13 sat behind the same return. (2) A drain kept commanding `discharge_w`
|
||||
with an unknown level, which breaks the TEL-08 rule that an unknown level never
|
||||
allows discharge.
|
||||
|
||||
## Rules
|
||||
|
||||
1. **Charge, no SoC.** The charge timeout (`CHARGE_TIMEOUT_MIN`, gate-open
|
||||
minutes) and the 7-day wall backstop still run. When one fires: if the last
|
||||
SoC seen was >= target - 3 the charge counts as done (the MAINT-13 "close
|
||||
enough to full" rule, HOLD follows); otherwise it fails: MAINT-13 back-off
|
||||
and its one notification. If no SoC was ever seen, it fails.
|
||||
2. **Drain, no SoC.** DRAIN holds at 0 W and owns the setpoint, exactly as HOLD
|
||||
does. The 12 h drain timeout still runs and fails as before.
|
||||
3. **SoC comes back.** Nothing is recorded; the drain continues at the drain
|
||||
rate, the charge carries on, and the stall wait of MAINT-13 restarts from
|
||||
what it was: it paused while the reading was missing, so a gap never counts
|
||||
as "no more charge".
|
||||
4. **HOLD** is unchanged (0 W).
|
||||
5. **Log.** One line when a drain starts holding for this reason ("the battery
|
||||
level is unknown, so the drain holds at 0 W until it is back"), and one line
|
||||
when the level has been missing for `NOSOC_NOTE_MIN` = 15 min. Both are said
|
||||
once per episode; the old line that repeated every tick is gone.
|
||||
|
||||
## Why
|
||||
|
||||
- **"Last seen", not "best seen".** A pack that was at 99 and then dropped to 50
|
||||
before the reading went is not close to full. Only the last reading counts.
|
||||
It is saved with the charge record (`charge_track.last`), and saved at once
|
||||
when the reading first goes missing, so a restart mid-gap still knows it
|
||||
(within the usual 5 min save interval otherwise).
|
||||
- **Failure when nothing was seen.** With no level we cannot call a pack full.
|
||||
The failure costs a 7-day wait and one notice; calling it done costs a
|
||||
missed balance and a month-long false "complete". The first is the honest one.
|
||||
- **Timeouts count the same minutes as with a reading.** Gate-open charging
|
||||
minutes only; the wall backstop for a gate that never opens.
|
||||
- **15 min.** A judgement. A poll glitch of a few minutes should not write a
|
||||
line; a reading lost for a quarter of an hour is worth one. Raise it if the
|
||||
action log shows noise.
|
||||
- **0 W, not "stop the phase".** Aborting a drain on a short gap would throw
|
||||
away the part already drained. Holding at 0 W loses nothing and the 12 h
|
||||
timeout is the limit.
|
||||
|
||||
## Cost
|
||||
|
||||
- A drain that loses its reading stops draining, and the 12 h clock keeps
|
||||
running. A gap of many hours can therefore fail a drain that was working. The
|
||||
back-off then applies (7 days).
|
||||
- A charge whose reading is lost early (last SoC below target - 3) fails at the
|
||||
timeout, even if the pack was in fact filling. The same 7-day wait applies.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- **HOLD with no SoC**: closed by MAINT-15 (`MAINT-15-hold-ends-without-soc.md`).
|
||||
- It does not tell the operator why the reading is missing (sensor, register,
|
||||
link). It does not reuse the stale-input gate; it is the cycle's own rule.
|
||||
- The charge itself is still driven by the control loop, which has its own
|
||||
handling of a missing SoC (TEL-08 for the loop is a separate card).
|
||||
- A restart loses at most 5 min of accounting, as in MAINT-13. The "unknown for
|
||||
long" line may be said again after a restart: the episode start is in memory.
|
||||
- Text added is two log lines, English only, like the other log lines.
|
||||
@@ -0,0 +1,47 @@
|
||||
# MAINT-15 - the balancing hold ends on time with no SoC reading
|
||||
|
||||
**Status: for review.** Tests: `test_maint15.py`. No option added.
|
||||
|
||||
**The fault.** `step()` sent every tick with no SoC to `_no_soc()`, and for
|
||||
HOLD that returned 0 W without the time check. A hold that lost its reading
|
||||
never ended: `last_completed` was never written and the next due date never
|
||||
moved. Harmless for power (0 W), but the cycle was stuck. This was left open
|
||||
in MAINT-14.
|
||||
|
||||
## Rule
|
||||
|
||||
1. **HOLD ends at `hold_min` whether or not there is a reading.** One helper,
|
||||
`Maintenance._hold()`, holds the time check and is used by both paths. When
|
||||
the time is up it writes `last_completed`, goes IDLE and logs the same
|
||||
"cycle COMPLETE" line. Before the time is up it commands 0 W as before.
|
||||
2. **Text.** The 15-min "no battery level" line in HOLD now reads "The hold
|
||||
still ends at its normal time." Still once per episode.
|
||||
|
||||
## Why
|
||||
|
||||
HOLD is reached only after the charge counted as done. Every entry into HOLD
|
||||
is in `step()` or `_no_soc()` and follows a charge that reached the target,
|
||||
stalled near full (MAINT-13) or timed out near full (MAINT-13/14). Nothing else
|
||||
sets the phase to HOLD (`_enter(HOLD` has four call sites, all after a done
|
||||
charge). The hold is a wait for the BMS to balance; it never needed the level.
|
||||
So a hold that ends with no reading is a completed cycle. The "cycle COMPLETE"
|
||||
line is true without a reading: it names minutes of hold, not a level.
|
||||
|
||||
## Cost
|
||||
|
||||
- If the level was lost during the hold, the cycle is recorded as complete
|
||||
without anyone seeing the final level. The charge had counted as done, so this
|
||||
is the same trust MAINT-14 already gives a charge that ends with no reading.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- It does not check that the pack is still full at the end of the hold.
|
||||
- It does not say why the reading was lost.
|
||||
- With a reading, nothing changes. `test_maint15.py` section 7 compares the new
|
||||
HOLD tick by tick with a frozen copy of the release/1.0 HOLD branch (phase,
|
||||
setpoint, owner, events, `last_completed`) at four `hold_min` values. A wider
|
||||
trace of the whole cycle (800 seeded runs against db9e231) was run outside the
|
||||
repo; its script and log are kept under `scratch/MAINT-15/` of the dev
|
||||
workspace, not in this repository.
|
||||
- A state file written by an older version with `phase: hold` loads and ends on
|
||||
time; the file is not changed in format.
|
||||
@@ -0,0 +1,96 @@
|
||||
# SAFETY-107 - a refusal held under another writer is learned once
|
||||
|
||||
**Status: for review.** Tests: `test_safety107.py`. One inverter only; nothing
|
||||
changes at N>1 (SAFETY-73's unit refusal has no "another writer" end).
|
||||
|
||||
**The defect** (MAINT-13 F5, MAINT-14 "seen again"). A full pack under a
|
||||
maintenance charge in a cheap window takes no charge. At N=1 the action log then
|
||||
showed "BATTERY REFUSES asked -2500 W ..." and "BATTERY REFUSES ENDED: another
|
||||
writer" every cycle: 548 + 548 lines in 15 min on the MAINT-13 rig head,
|
||||
652 + 651 in 12 min on its base, 33 + 32 in 60 s in MAINT-14's c2b. The 40-line
|
||||
log flooded and the hint under the buttons changed every second, so the
|
||||
MAINT-13 notice was gone at once.
|
||||
|
||||
**Cause** (`main.py`, the SAFETY-52 block before `compute()`). The end tested
|
||||
`self.target != self.loop_w`: the wire differs from the loop's ask. A held
|
||||
refusal makes the loop ask 0 W, so any claim that binds (the maintenance
|
||||
charge's `hi`, the peak guard's `lo`, a trade's SET) differs from it on every
|
||||
cycle. The refusal was ended against the same writer it had been learned
|
||||
against. `sat_count` is not reset by that end, so `compute()` learned the same
|
||||
refusal again in the same cycle. Nothing about the battery or the wire had
|
||||
changed; only the log and the hint did.
|
||||
|
||||
**Other writers.** The same flap comes from any writer that holds the wire
|
||||
while the loop is refused, as long as the evidence lasts: a trade (a SET at
|
||||
P_ARBITRAGE) into a full pack, and the peak guard over an empty pack: 335
|
||||
refusal lines in 15 min each at a 5 s meter (`test_safety107.py` part 2, run on
|
||||
release/1.0).
|
||||
A maintenance drain or hold does not flap: its SET resets `sat_count` each cycle.
|
||||
|
||||
**The rule** (`_refusal_update()`, `rejudged`). When another writer held the
|
||||
wire, the held refusal is judged afresh: `compute()` gets `refused=0` and no
|
||||
probe, exactly as before the change. Then:
|
||||
|
||||
1. it finds the same refusal against that writer's ask: the same episode
|
||||
continues, with no line and no hint. The probe clock restarts, as it did on
|
||||
the old end and start: a probe is the loop's ask, and it is not on the wire
|
||||
while another writer is;
|
||||
2. it does not: the refusal ends, logged "another writer", or "the battery
|
||||
gives power" when the reading shows it (it was "another writer" before);
|
||||
3. it finds the other direction: end, then a new start, as before. In
|
||||
practice 2 comes first: SAFETY-94's evidence restarts when the ask changes
|
||||
sign, so a writer that turns round ends the refusal at once and the other
|
||||
way is learned ~12 cycles later (`test_safety107.py` part 3e).
|
||||
|
||||
**Why this rule.** The end now means what SAFETY-52 meant by it: the refusal no
|
||||
longer describes what is on the wire, judged by the same test that learns it.
|
||||
`compute()` sees the same inputs as before and the state after each cycle is
|
||||
the same (`batt_refused`, `batt_refused_at`), so every command is unchanged.
|
||||
Keeping the held refusal into `compute()` instead (mutation M5) would also
|
||||
stop the lines, but it holds the loop at 0 W where the old law let it ask past
|
||||
a writer's limit, which changes commands; it also removes SAFETY-52's
|
||||
owner-decided "another writer" exit.
|
||||
|
||||
**Evidence.**
|
||||
- Differential trace (`goodwe/scratch/SAFETY-107/probe/trace.py`, not in this
|
||||
repo; the real Controller in the CI image, release/1.0 bf3ac79 against this
|
||||
tree): 300 seeds, N=1 (153) and
|
||||
N=2 (147), 1/2/5 s meter, full/empty/dead/healthy battery windows, a stepping
|
||||
house, maintenance charge with the cheap window opening and closing, P1 and
|
||||
the peak guard, trade windows, stop/start; 427 680 cycles, 294 seeds with a
|
||||
refusal held. Every command, site target, integrator, `sat_count`, refusal
|
||||
state and reason is identical. Refusal lines: 100 748 before, 2 188 after.
|
||||
- The card's case: 1 line in 15 min at N=1 and N=2, 1/2/5 s meter, house
|
||||
importing or exporting (release/1.0: 335-1 753 at N=1; N=2 was already 1).
|
||||
|
||||
**Mutations** (`tools/mutation_run.sh` on purged copies; reds in
|
||||
test_safety107 / test_refusal / test_refusal_units; trace = seeds of 300 whose
|
||||
commands differ from release/1.0):
|
||||
|
||||
| | mutation | reds | trace |
|
||||
|---|---|---|---|
|
||||
| M1 | `now == rejudged` -> `False` (every such cycle ends: the old flap) | 26 / 0 / 0 | 0 |
|
||||
| M2 | `rejudged` always 0 (another writer never ends it) | 5 / 1 / 2 | 29 |
|
||||
| M3 | the probe clock is not restarted on a continued episode | 1 / 0 / 0 | 2 |
|
||||
| M4 | a probe may open while rejudged | 0 / 0 / 0 | 0 |
|
||||
| M5 | the held refusal goes into `compute()` while rejudged | 2 / 1 / 2 | 27 |
|
||||
| M6 | an end while rejudged always says "another writer" | 1 / 0 / 0 | 0 |
|
||||
|
||||
M4 is equivalent: a probe matters only if `compute()` engages in that call,
|
||||
which needs `SETTLE_CYCLES` saturated against the writer, and each of those
|
||||
cycles restarted the clock. The line stays because it states the rule.
|
||||
|
||||
**Cost.** None in power. A takeover by a different writer while the battery
|
||||
still refuses is logged as an end and, ~12 cycles later, a new start against
|
||||
that writer (3 lines for the episode, `test_safety107.py` part 3a).
|
||||
|
||||
**Not covered.**
|
||||
- A perfectly flat reading under a writer. The stale-reading gate trips, stops
|
||||
the site and seeds the refusal (SAFETY-52 decision 3). After the stop the
|
||||
writer's ask returns fresh, `compute()` has no saturation history against it,
|
||||
so the refusal ends at the first cycle and the next trip seeds it again: 2
|
||||
lines per gate cycle (29 in 15 min, house exporting), the same as release/1.0.
|
||||
The gate cycle itself (0 W, then the writer's ask) is the cause; stopping it
|
||||
changes commands. None of the rig runs showed it: real readings move.
|
||||
- At N=1 a refusal shapes only the loop. A writer above it still asks the
|
||||
battery; at N>1 SAFETY-73's P_SAFETY claim binds every writer.
|
||||
@@ -605,6 +605,10 @@ still moving towards the request, such as one turning from charging to
|
||||
giving (SAFETY-94). "Gives" is counted from what the battery's reading shows
|
||||
at rest, which the add-on learns after two quiet minutes and keeps: some
|
||||
inverters show about -100 W at rest (SAFETY-97).
|
||||
While another task sets the power, such as a maintenance charge, the peak
|
||||
guard or a trade, the refusal stays as long as the battery still refuses that
|
||||
task's request. It is logged once, and the 200 W test waits until control sets
|
||||
the power again (SAFETY-107).
|
||||
|
||||
**With two or more inverters** the same rule works per inverter. An inverter
|
||||
whose battery gives less than 100 W for 12 cycles, and at least 22 s, while
|
||||
@@ -618,7 +622,7 @@ If the battery refuses to give power while its level reads above its “Battery
|
||||
cut-out level”, the log adds one warning ending in `REFUSES_ABOVE_CUT_OUT`: check that setting.
|
||||
A battery that refuses is not reported as *not delivering*.
|
||||
|
||||
*For installers:* SAFETY-52 and SAFETY-73. The event log reads
|
||||
*For installers:* SAFETY-52, SAFETY-73 and SAFETY-107. The event log reads
|
||||
`BATTERY REFUSES …` and `BATTERY REFUSES ENDED …` (with the inverter's name at
|
||||
N>1), and the INFO line ends in `BATTERY_REFUSES`.
|
||||
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures and
|
||||
|
||||
@@ -1279,9 +1279,26 @@ class Controller:
|
||||
_LOG.info("The battery refusal ends, control asks for power again: %s.",
|
||||
why)
|
||||
|
||||
def _refusal_update(self, decision, asked_w, batt_w, probe) -> None:
|
||||
"""Follow `compute()`'s carried refused direction, and say so."""
|
||||
def _refusal_update(self, decision, asked_w, batt_w, probe,
|
||||
rejudged: int = 0) -> None:
|
||||
"""Follow `compute()`'s carried refused direction, and say so.
|
||||
|
||||
`rejudged`: the refusal held while another writer had the wire, so
|
||||
`compute()` judged it afresh against that writer's ask (SAFETY-107).
|
||||
"""
|
||||
now = decision.refused or 0
|
||||
if rejudged:
|
||||
if now == rejudged:
|
||||
# Still refused against the ask on the wire: the same episode.
|
||||
# The probe clock restarts, as it did when this was an end and
|
||||
# a new start: a probe is the loop's ask, and it is not on the
|
||||
# wire while another writer is.
|
||||
self.batt_refused_at = self._now_mono
|
||||
return
|
||||
gave = (rejudged * (batt_w - self._site_idle_w())
|
||||
>= _ctl.PROBE_ANSWER_W)
|
||||
self._refusal_end("the battery gives power" if gave
|
||||
else "another writer")
|
||||
if now and not self.batt_refused:
|
||||
self._refusal_start(now, f"asked {asked_w:+.0f} W, the battery "
|
||||
f"gave {batt_w:+.0f} W for "
|
||||
@@ -4973,11 +4990,15 @@ class Controller:
|
||||
if trade_was and not mode_trade:
|
||||
self._reseed_run_edge(claims)
|
||||
# SAFETY-52: another writer overrode the loop, so a refusal learned
|
||||
# against the loop's own ask no longer describes the wire. A gap
|
||||
# against the loop's own ask may no longer describe the wire. A gap
|
||||
# (`loop_w` None: blind or stopped) keeps it: the stale-reading stop
|
||||
# is what seeds it, and dropping it there restarts the ~70 s cycle.
|
||||
# SAFETY-107: it ends only if compute() no longer finds it against
|
||||
# that writer's ask (`_refusal_update()`). A held refusal makes the
|
||||
# loop ask 0 W, so any claim that binds differs from it every cycle.
|
||||
rejudged = 0
|
||||
if self.loop_w is not None and self.target != self.loop_w:
|
||||
self._refusal_end("another writer")
|
||||
rejudged = self.batt_refused
|
||||
# SAFETY-96: a battery that dropped out of the split leaves the
|
||||
# loop's start point (SAFETY-93's own if its charge ended too).
|
||||
self._reseed_drop(_live96)
|
||||
@@ -4986,7 +5007,8 @@ class Controller:
|
||||
# SAFETY-95: then a drain that ended, last (it reads the start
|
||||
# the others left).
|
||||
self._reseed_drain_end(maint_results, _live96)
|
||||
probe = self._refusal_probe()
|
||||
# No probe while it is judged afresh (the loop does not hold the wire).
|
||||
probe = False if rejudged else self._refusal_probe()
|
||||
if len(self.inverters) > 1:
|
||||
probe = any(_probing.values())
|
||||
# ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF.
|
||||
@@ -5029,7 +5051,8 @@ class Controller:
|
||||
# limit already closes an empty battery's discharge end.
|
||||
# SAFETY-73: at N>1 the site law holds 0 W only while every
|
||||
# unit refuses the same way. Otherwise None, the old law.
|
||||
refused=self.batt_refused if len(self.inverters) == 1
|
||||
refused=(0 if rejudged else self.batt_refused)
|
||||
if len(self.inverters) == 1
|
||||
else self._site_refused(),
|
||||
probe=probe,
|
||||
# SAFETY-94: at N=1 the engage also needs the reading to have
|
||||
@@ -5055,7 +5078,8 @@ class Controller:
|
||||
self.loop_w = decision.target_w
|
||||
self._loop_decision = decision
|
||||
if len(self.inverters) == 1:
|
||||
self._refusal_update(decision, loop_prev, site_batt, probe)
|
||||
self._refusal_update(decision, loop_prev, site_batt, probe,
|
||||
rejudged)
|
||||
# --- TEL-10 ------------------------------------------------------
|
||||
# ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT
|
||||
# THE CARD IS. `self.i_w` is carried between cycles and published
|
||||
|
||||
@@ -84,6 +84,10 @@ FAIL_BACKOFF_DAYS = 7
|
||||
CHARGE_TICK_MAX_MIN = 5
|
||||
# The charge accounting is written to the state file at most this often.
|
||||
CHARGE_SAVE_MIN = 5
|
||||
# MAINT-14 (DECISIONS/MAINT-14-no-soc-in-maintenance.md): with no SoC reading
|
||||
# the timeouts still run, a drain holds at 0 W, and the log says once, after this
|
||||
# many minutes, that the level has been unknown for long.
|
||||
NOSOC_NOTE_MIN = 15
|
||||
|
||||
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR EVERY `maintenance_*`
|
||||
# OPTION, and the only place in the add-on where one of these numbers is typed.
|
||||
@@ -367,6 +371,10 @@ class Maintenance:
|
||||
# written to the state file every CHARGE_SAVE_MIN minutes.
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
# MAINT-14: when the SoC reading went missing (None while it is there),
|
||||
# and whether the "unknown for long" line was said in this episode.
|
||||
self._nosoc_since = None
|
||||
self._nosoc_said = False
|
||||
|
||||
# -- state ---------------------------------------------------------------
|
||||
@property
|
||||
@@ -374,6 +382,7 @@ class Maintenance:
|
||||
return self.store.get("phase", IDLE)
|
||||
|
||||
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
|
||||
self._nosoc_since = None
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
if self.store.get("charge_track") is not None:
|
||||
@@ -473,7 +482,8 @@ class Maintenance:
|
||||
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
|
||||
return events
|
||||
|
||||
def _charge_account(self, now: datetime, soc: float, gate_open: bool) -> dict:
|
||||
def _charge_account(self, now: datetime, soc: float | None,
|
||||
gate_open: bool) -> dict:
|
||||
"""MAINT-13: what this charge has used so far, as minutes of ALLOWED time.
|
||||
|
||||
`open_min` counts only ticks with the price gate open; `flat_min` counts
|
||||
@@ -481,6 +491,9 @@ class Maintenance:
|
||||
both. One tick adds at most CHARGE_TICK_MAX_MIN, so a gap (add-on down)
|
||||
counts for nothing. A state file from before MAINT-13, or from another
|
||||
charge, starts from the wall-clock minutes so far: the old behaviour.
|
||||
|
||||
MAINT-14: `soc` may be None (no reading). Time still counts, the stall
|
||||
wait pauses, and `last` keeps the last SoC seen (saved with the rest).
|
||||
"""
|
||||
since = self.store.get("phase_started")
|
||||
trk = self._trk
|
||||
@@ -490,7 +503,9 @@ class Maintenance:
|
||||
trk = dict(raw)
|
||||
else:
|
||||
trk = {"since": since, "open_min": self._elapsed_min(now),
|
||||
"flat_min": 0.0, "best": float(soc), "at": None}
|
||||
"flat_min": 0.0,
|
||||
"best": None if soc is None else float(soc),
|
||||
"last": None if soc is None else float(soc), "at": None}
|
||||
self._trk = trk
|
||||
at = trk.get("at")
|
||||
try:
|
||||
@@ -500,10 +515,14 @@ class Maintenance:
|
||||
dt = 0.0 if last is None else min(
|
||||
CHARGE_TICK_MAX_MIN, max(0.0, (now - last).total_seconds() / 60.0))
|
||||
trk["at"] = now.isoformat()
|
||||
if soc > trk["best"]:
|
||||
if soc is None:
|
||||
pass
|
||||
elif trk.get("best") is None or soc > trk["best"]:
|
||||
trk["best"], trk["flat_min"] = float(soc), 0.0
|
||||
elif gate_open:
|
||||
trk["flat_min"] += dt
|
||||
if soc is not None:
|
||||
trk["last"] = float(soc)
|
||||
if gate_open:
|
||||
trk["open_min"] += dt
|
||||
saved = self._trk_saved
|
||||
@@ -522,6 +541,81 @@ class Maintenance:
|
||||
events.append(msg)
|
||||
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
|
||||
|
||||
def _hold(self, now: datetime, events: list) -> MaintResult:
|
||||
"""HOLD for one tick, with or without a SoC reading (MAINT-15).
|
||||
|
||||
HOLD needs no level to end: it is reached only after the charge counted
|
||||
as done (MAINT-13/14), so its end is a time check and nothing else.
|
||||
"""
|
||||
elapsed = self._elapsed_min(now)
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
|
||||
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
|
||||
events: list) -> MaintResult:
|
||||
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
|
||||
|
||||
HOLD stays at 0 W and ends at its normal time (MAINT-15). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
|
||||
time is a failure, except when the last SoC seen was within
|
||||
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
|
||||
Nothing here may start a phase change that needs the level.
|
||||
"""
|
||||
if self._nosoc_since is None:
|
||||
self._nosoc_since = now
|
||||
self._nosoc_said = False
|
||||
self._trk_saved = None # save the last SoC seen, now
|
||||
if phase == DRAIN:
|
||||
msg = ("maintenance: the battery level is unknown, so the "
|
||||
"drain holds at 0 W until it is back.")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
|
||||
>= NOSOC_NOTE_MIN * 60):
|
||||
self._nosoc_said = True
|
||||
tail = ("The hold still ends at its normal time."
|
||||
if phase == HOLD else
|
||||
f"The time limit of the {phase} still applies.")
|
||||
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
|
||||
f"{tail}")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if phase == HOLD:
|
||||
return self._hold(now, events)
|
||||
elapsed = self._elapsed_min(now)
|
||||
if phase == DRAIN:
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
return self._fail(now, "drain",
|
||||
f"drain stuck, battery level unknown, after "
|
||||
f"{elapsed / 60:.0f} h")
|
||||
return MaintResult(DRAIN, True, 0.0, False, events)
|
||||
trk = self._charge_account(now, None, gate_open)
|
||||
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
|
||||
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
|
||||
last = trk.get("last")
|
||||
if last is not None and last >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: charge time is up and the last level "
|
||||
f"seen was {last:.0f} %, close enough to full, so the "
|
||||
f"charge counts as done -> holding "
|
||||
f"{self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
if elapsed > CHARGE_WALL_TIMEOUT_MIN:
|
||||
lim = f"the {CHARGE_WALL_TIMEOUT_MIN // 1440}-day limit"
|
||||
else:
|
||||
lim = f"{trk['open_min'] / 60:.0f} h of charging time"
|
||||
return self._fail(now, "charge",
|
||||
f"charge stuck, battery level unknown, after {lim}")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
def abort(self, now: datetime, why: str) -> list:
|
||||
events = []
|
||||
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
|
||||
@@ -609,13 +703,13 @@ class Maintenance:
|
||||
# transitions below mean anything, and a stale "100 %" would end the
|
||||
# charge phase having charged nothing. Hold the current phase's command
|
||||
# and wait; the phase timeout is the backstop.
|
||||
#
|
||||
# MAINT-14: "hold and wait" is not "wait for ever". The timeouts run
|
||||
# here too, and a drain holds at 0 W (an unknown level never allows
|
||||
# discharge, TEL-08). See `_no_soc`.
|
||||
if soc is None:
|
||||
_LOG.warning("maintenance: no SoC reading, holding phase %s", phase)
|
||||
if phase == DRAIN:
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
return self._no_soc(now, phase, gate_open, events)
|
||||
self._nosoc_since = None
|
||||
|
||||
elapsed = self._elapsed_min(now)
|
||||
|
||||
@@ -660,16 +754,7 @@ class Maintenance:
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
if phase == HOLD:
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._hold(now, events)
|
||||
|
||||
_LOG.error("maintenance: unknown phase %r, forcing idle", phase)
|
||||
events += self.abort(now, f"unknown phase {phase!r}")
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.16.0"
|
||||
version: "0.17.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
|
||||
@@ -0,0 +1,403 @@
|
||||
"""MAINT-14: maintenance with no SoC reading.
|
||||
`python3 test_maint14.py`
|
||||
|
||||
Graded here: charge and drain with SoC None at one and two packs - the charge
|
||||
timeout and 7 day backstop still run (failure, or done when the last SoC was
|
||||
>= target - 3), the drain holds at 0 W and times out, SoC coming back resumes
|
||||
normally with no back-off, the log lines (once per episode), a restart while the
|
||||
SoC is missing, and one pack's missing SoC leaving the other pack alone.
|
||||
See DECISIONS/MAINT-14-no-soc-in-maintenance.md.
|
||||
|
||||
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
|
||||
"""
|
||||
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.maintenance import (
|
||||
CHARGE, CHARGE_NEAR_FULL_PCT, CHARGE_TIMEOUT_MIN, CHARGE_WALL_TIMEOUT_MIN,
|
||||
DRAIN, DRAIN_TIMEOUT_MIN, FAIL_BACKOFF_DAYS, HOLD, IDLE, NOSOC_NOTE_MIN,
|
||||
MaintConfig, Maintenance, arbitrate,
|
||||
)
|
||||
from app.store import DEFAULTS, Store
|
||||
|
||||
UTC = timezone.utc
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=120)
|
||||
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC)
|
||||
MIN = timedelta(minutes=1)
|
||||
|
||||
|
||||
class Mem:
|
||||
def __init__(self, data=None):
|
||||
self.data = dict(DEFAULTS, **(data or {}))
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def set_time(self, k, when):
|
||||
self.data[k] = when.astimezone(UTC).isoformat() if when else None
|
||||
|
||||
def get_time(self, k):
|
||||
raw = self.data.get(k)
|
||||
return datetime.fromisoformat(raw) if raw else None
|
||||
|
||||
def save(self):
|
||||
pass
|
||||
|
||||
|
||||
def in_drain(store=None, unit=None, at=T0):
|
||||
m = Maintenance(CFG, store or Mem(), unit=unit, name=unit or "")
|
||||
m.force_start(at)
|
||||
assert m.phase == DRAIN
|
||||
return m
|
||||
|
||||
|
||||
def in_charge(store=None, unit=None, at=T0):
|
||||
m = in_drain(store, unit, at)
|
||||
m.tick(at, 11.0)
|
||||
assert m.phase == CHARGE
|
||||
return m
|
||||
|
||||
|
||||
def run(m, start, minutes, soc, gate=True, step=1):
|
||||
"""Tick every `step` min; returns (last result, end time, first result that
|
||||
is not the starting phase with its time, all events)."""
|
||||
ph, t, res, out, ev = m.phase, start, None, None, []
|
||||
for i in range(0, minutes, step):
|
||||
t = start + i * MIN
|
||||
s = soc(i) if callable(soc) else soc
|
||||
res = m.tick(t, s, gate_open=gate)
|
||||
ev += res.events
|
||||
if out is None and res.phase != ph:
|
||||
out = (res, t)
|
||||
break
|
||||
return res, start + minutes * MIN, out, ev
|
||||
|
||||
|
||||
print("1. charge with no SoC")
|
||||
m = in_charge()
|
||||
res, _, out, _ = run(m, T0, 600, None)
|
||||
check("it keeps charging: the loop owns the setpoint, no start of a new phase",
|
||||
out is None and res.phase == CHARGE and res.charge_only
|
||||
and not res.owns_setpoint)
|
||||
|
||||
m = in_charge()
|
||||
run(m, T0, 60, 60.0)
|
||||
res, _, out, ev = run(m, T0 + 60 * MIN, CHARGE_TIMEOUT_MIN + 10, None)
|
||||
check("the charge timeout still runs: it fails once the time is up (last SoC 60)",
|
||||
out and out[0].failed == "charge" and out[0].phase == IDLE)
|
||||
check("...with the MAINT-13 back-off and its one plain line",
|
||||
m.store.get_time("last_failed") is not None
|
||||
and sum("did not finish" in e for e in ev) == 1
|
||||
and f"{FAIL_BACKOFF_DAYS} days" in ev[-1])
|
||||
check("...it took 36 h of allowed time from the charge start, not more",
|
||||
out and out[1] <= T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 10))
|
||||
check("...and the pack does not want a start in the back-off",
|
||||
not m.wants_start((T0 + timedelta(days=3)).replace(hour=19)))
|
||||
|
||||
m = in_charge()
|
||||
res, _, out, _ = run(m, T0, CHARGE_TIMEOUT_MIN + 10, None)
|
||||
check("never saw a SoC: the timeout is a failure, not 'done'",
|
||||
out and out[0].failed == "charge")
|
||||
|
||||
for last in (97.0, 99.0):
|
||||
m = in_charge()
|
||||
run(m, T0, 10, last)
|
||||
res, _, out, ev = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
check(f"last SoC {last:.0f} (>= target - {CHARGE_NEAR_FULL_PCT}): time up counts as done",
|
||||
out and out[0].phase == HOLD and out[0].failed == ""
|
||||
and m.store.get_time("last_failed") is None)
|
||||
check("...one plain line says so",
|
||||
sum("counts as done" in e for e in ev) == 1
|
||||
and f"{last:.0f} %" in " ".join(ev))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 96.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
check("last SoC 96 (below target - 3): time up is a failure",
|
||||
out and out[0].failed == "charge")
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 99.0)
|
||||
run(m, T0 + 10 * MIN, 10, 50.0)
|
||||
res, _, out, _ = run(m, T0 + 20 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
check("'last seen' is the last reading, not the best (99 then 50: failure)",
|
||||
out and out[0].failed == "charge")
|
||||
|
||||
print("2. the 7 day backstop, with the gate shut")
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
|
||||
gate=False, step=5)
|
||||
check("gate never opens, last SoC 70: failure at 7 days",
|
||||
out and out[0].failed == "charge"
|
||||
and out[1] >= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN)
|
||||
and out[1] <= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN + 10))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 98.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
|
||||
gate=False, step=5)
|
||||
check("gate never opens, last SoC 98: done at 7 days",
|
||||
out and out[0].phase == HOLD and out[0].failed == ""
|
||||
and out[1] >= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, 3000, None, gate=False, step=5)
|
||||
check("gate shut, no SoC: the open-time clock does not run (no early end)",
|
||||
out is None)
|
||||
|
||||
print("3. SoC comes back mid-charge")
|
||||
m = in_charge()
|
||||
run(m, T0, 30, 80.0)
|
||||
run(m, T0 + 30 * MIN, 600, None)
|
||||
res, _, out, _ = run(m, T0 + 630 * MIN, 5, 80.0)
|
||||
check("normal behaviour resumes: still charging, nothing recorded",
|
||||
out is None and res.phase == CHARGE
|
||||
and m.store.get_time("last_failed") is None)
|
||||
res, _, out, _ = run(m, T0 + 640 * MIN, 10, 100.0)
|
||||
check("...and it completes at the target as usual",
|
||||
out and out[0].phase == HOLD and m.store.get_time("last_failed") is None)
|
||||
m = in_charge()
|
||||
run(m, T0, 30, 98.0)
|
||||
run(m, T0 + 30 * MIN, 600, None)
|
||||
res, _, out, _ = run(m, T0 + 630 * MIN, 30, 98.0)
|
||||
check("the stall wait paused while the SoC was missing (30 min flat after the "
|
||||
"gap is not 60)", out is None)
|
||||
res, _, out, _ = run(m, T0 + 660 * MIN, 40, 98.0)
|
||||
check("...and completes once 60 min flat are in", out and out[0].phase == HOLD)
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN - 100, None)
|
||||
res, _, out, _ = run(m, T0 + (CHARGE_TIMEOUT_MIN - 90) * MIN, 5, 70.0)
|
||||
check("a gap just before the limit then a reading: no failure, no back-off",
|
||||
out is None and m.store.get_time("last_failed") is None)
|
||||
|
||||
print("4. drain with no SoC")
|
||||
m = in_drain()
|
||||
run(m, T0, 30, 60.0)
|
||||
res, _, out, ev = run(m, T0 + 30 * MIN, 60, None)
|
||||
check("DRAIN holds at 0 W, owned by maintenance, the same as HOLD",
|
||||
out is None and res.phase == DRAIN and res.owns_setpoint
|
||||
and res.setpoint_w == 0.0 and not res.charge_only)
|
||||
hold = in_charge()
|
||||
hold.tick(T0 + MIN, 100.0)
|
||||
hr = hold.tick(T0 + 2 * MIN, None)
|
||||
check("...the same answer as HOLD gives",
|
||||
(hr.owns_setpoint, hr.setpoint_w) == (res.owns_setpoint, res.setpoint_w))
|
||||
check("never above 0 W on any missing tick",
|
||||
all(m.tick(T0 + (100 + i) * MIN, None).setpoint_w == 0.0 for i in range(30)))
|
||||
check("one plain line that the drain holds, once, not per tick",
|
||||
sum("drain holds at 0 W" in e for e in ev) == 1)
|
||||
check("one plain line after the threshold, once",
|
||||
sum("no battery level for" in e for e in ev) == 1
|
||||
and f"{NOSOC_NOTE_MIN} min" in " ".join(ev))
|
||||
m = in_drain()
|
||||
res, _, out, ev = run(m, T0, NOSOC_NOTE_MIN - 1, None)
|
||||
check("under the threshold the 'no level for long' line is not said",
|
||||
not any("no battery level for" in e for e in ev))
|
||||
m = in_drain()
|
||||
res, _, out, ev = run(m, T0, DRAIN_TIMEOUT_MIN + 10, None)
|
||||
check("the 12 h drain timeout still runs: failure with back-off",
|
||||
out and out[0].failed == "drain" and out[0].phase == IDLE
|
||||
and out[1] > T0 + timedelta(minutes=DRAIN_TIMEOUT_MIN)
|
||||
and m.store.get_time("last_failed") is not None)
|
||||
m = in_drain()
|
||||
run(m, T0, 60, None)
|
||||
res, _, out, _ = run(m, T0 + 60 * MIN, 5, 60.0)
|
||||
check("SoC back: the drain continues at the drain rate",
|
||||
out is None and res.phase == DRAIN and res.owns_setpoint
|
||||
and res.setpoint_w == CFG.discharge_w)
|
||||
res, _, out, _ = run(m, T0 + 70 * MIN, 5, 10.0)
|
||||
check("...and ends at the floor as usual",
|
||||
out and out[0].phase == CHARGE and m.store.get_time("last_failed") is None)
|
||||
m = in_drain()
|
||||
run(m, T0, 60, None)
|
||||
run(m, T0 + 60 * MIN, 5, 60.0)
|
||||
res, _, out, ev = run(m, T0 + 70 * MIN, 5, None)
|
||||
check("a second episode says its lines again",
|
||||
any("drain holds at 0 W" in e for e in ev))
|
||||
|
||||
print("5. the log is once per episode")
|
||||
m = in_charge()
|
||||
res, _, out, ev = run(m, T0, 300, None)
|
||||
check("a 5 h charge episode: exactly one 'no level for long' line, none per tick",
|
||||
len(ev) == 1 and "no battery level for" in ev[0])
|
||||
run(m, T0 + 300 * MIN, 3, 70.0)
|
||||
res, _, out, ev = run(m, T0 + 303 * MIN, 60, None)
|
||||
check("...and one more for a new episode", len(ev) == 1)
|
||||
m = in_charge()
|
||||
res, _, out, ev = run(m, T0, 5, None)
|
||||
check("a 5 min gap says nothing", ev == [])
|
||||
|
||||
print("5b. the words per phase")
|
||||
m = in_charge()
|
||||
m.tick(T0 + MIN, 100.0)
|
||||
_, _, _, ev = run(m, T0 + 2 * MIN, 30, None)
|
||||
note = [e for e in ev if "no battery level for" in e]
|
||||
check("HOLD: the line exists and says the hold ends at its normal time (MAINT-15)",
|
||||
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0])
|
||||
m = in_charge()
|
||||
_, _, _, ev = run(m, T0, 30, None)
|
||||
check("charge keeps its wording", any("time limit of the charge" in e for e in ev))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
_, _, out, ev = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
|
||||
gate=False, step=5)
|
||||
fail = [e for e in ev if "ABORT" in e]
|
||||
check("7-day backstop: the reason names the 7-day limit, not '0 h'",
|
||||
len(fail) == 1 and "7-day limit" in fail[0] and "0 h" not in fail[0])
|
||||
m = in_charge()
|
||||
_, _, out, ev = run(m, T0, CHARGE_TIMEOUT_MIN + 10, None)
|
||||
fail = [e for e in ev if "ABORT" in e]
|
||||
check("charge-time limit: the reason gives the hours of charging time",
|
||||
len(fail) == 1 and "36 h of charging time" in fail[0])
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 98.0)
|
||||
_, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
_, _, _, ev = run(m, out[1] + MIN, 30, None)
|
||||
check("charge done with no SoC, then HOLD with no SoC: a new episode, so the "
|
||||
"HOLD line is said", out[0].phase == HOLD
|
||||
and sum("normal time" in e for e in ev) == 1)
|
||||
|
||||
print("6. restart while the SoC is missing")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
path = os.path.join(d, "state.json")
|
||||
m = Maintenance(CFG, Store(path))
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
run(m, T0, 97, lambda i: 90.0 if i < 96 else 98.0) # 98 seen 1 min ago
|
||||
run(m, T0 + 97 * MIN, 3, None) # SoC lost; state saved at once
|
||||
t = T0 + 100 * MIN # restart 3 min after the loss, before the next 5 min save
|
||||
m2 = Maintenance(CFG, Store(path))
|
||||
r = m2.tick(t, None)
|
||||
check("a fresh process reads charge, and still charges", m2.phase == CHARGE
|
||||
and r.phase == CHARGE and r.charge_only)
|
||||
check("...with the open minutes and the last SoC seen from the file",
|
||||
m2._trk is not None and m2._trk["last"] == 98.0
|
||||
and 92 <= m2._trk["open_min"] <= 105)
|
||||
res, _, out, _ = run(m2, t + MIN, CHARGE_TIMEOUT_MIN, None, step=5)
|
||||
check("...so the timeout counts from the first charge minute and, with the "
|
||||
"last SoC 98, completes (no failure)",
|
||||
out and out[0].phase == HOLD and out[0].failed == ""
|
||||
and out[1] < T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 60))
|
||||
# drain: restart keeps it at 0 W and keeps the clock
|
||||
path2 = os.path.join(d, "s2.json")
|
||||
md = Maintenance(CFG, Store(path2))
|
||||
md.force_start(T0)
|
||||
md.tick(T0 + 100 * MIN, None)
|
||||
md2 = Maintenance(CFG, Store(path2))
|
||||
r = md2.tick(T0 + 101 * MIN, None)
|
||||
check("a drain restarted with no SoC holds at 0 W", md2.phase == DRAIN
|
||||
and r.setpoint_w == 0.0 and r.owns_setpoint)
|
||||
res, _, out, _ = run(md2, T0 + 102 * MIN, DRAIN_TIMEOUT_MIN, None, step=5)
|
||||
check("...and the 12 h clock is from the drain start, not the restart",
|
||||
out and out[0].failed == "drain"
|
||||
and out[1] <= T0 + timedelta(minutes=DRAIN_TIMEOUT_MIN + 10))
|
||||
# a charge restarted with no record of any SoC (old state file)
|
||||
old = {"phase": "charge", "phase_started": (T0 - timedelta(hours=35)).isoformat(),
|
||||
"last_completed": None, "last_start_attempt": None, "auto": True}
|
||||
import json
|
||||
path3 = os.path.join(d, "s3.json")
|
||||
json.dump(old, open(path3, "w"))
|
||||
mo = Maintenance(CFG, Store(path3))
|
||||
res, _, out, _ = run(mo, T0, 120, None)
|
||||
check("an old state file with no SoC seen: the charge fails at 36 h",
|
||||
out and out[0].failed == "charge")
|
||||
# a MAINT-13 state file: charge_track with a best but no `last`
|
||||
since = (T0 - timedelta(hours=35)).isoformat()
|
||||
m13 = dict(old, phase_started=since, charge_track={
|
||||
"since": since, "open_min": 2100.0, "flat_min": 0.0, "best": 99.0,
|
||||
"at": (T0 - MIN).isoformat()})
|
||||
path4 = os.path.join(d, "s4.json")
|
||||
json.dump(m13, open(path4, "w"))
|
||||
mo = Maintenance(CFG, Store(path4))
|
||||
res, _, out, _ = run(mo, T0, 120, None)
|
||||
check("a MAINT-13 state file (no last SoC): no crash, the charge fails at "
|
||||
"36 h (best is not last)", out and out[0].failed == "charge")
|
||||
|
||||
print("7. two packs")
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a.force_start(T0)
|
||||
# the twin site: the same two packs, A healthy (SoC 60, still above the floor)
|
||||
a_ok, b_alone = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a_ok.force_start(T0)
|
||||
same = True
|
||||
for i in range(0, 120, 10):
|
||||
t = T0 + i * MIN
|
||||
plan = arbitrate([a, b], t)
|
||||
plan0 = arbitrate([a_ok, b_alone], t)
|
||||
same = same and plan[1] == plan0[1]
|
||||
ra = a.tick(t, None, blocked_by=plan[0])
|
||||
rb = b.tick(t, 55.0, blocked_by=plan[1])
|
||||
a_ok.tick(t, 60.0, blocked_by=plan0[0])
|
||||
rb0 = b_alone.tick(t, 55.0, blocked_by=plan0[1])
|
||||
same = same and (rb.phase, rb.setpoint_w, rb.deferred) == \
|
||||
(rb0.phase, rb0.setpoint_w, rb0.deferred)
|
||||
check("A drains with no SoC at 0 W while B (SoC 55, idle) is as it is when A "
|
||||
"is healthy", ra.setpoint_w == 0.0 and ra.owns_setpoint and rb.phase == IDLE
|
||||
and rb.setpoint_w is None and not rb.owns_setpoint)
|
||||
check("...B's answers are unchanged tick by tick", same)
|
||||
res = None
|
||||
for i in range(0, DRAIN_TIMEOUT_MIN + 30, 10):
|
||||
t = T0 + 120 * MIN + i * MIN
|
||||
plan = arbitrate([a, b], t)
|
||||
res = a.tick(t, None, blocked_by=plan[0])
|
||||
b.tick(t, 55.0, blocked_by=plan[1])
|
||||
if res.failed:
|
||||
break
|
||||
check("A's drain times out and A backs off (A's keys only)",
|
||||
res.failed == "drain" and a.store.get_time("last_failed") is not None
|
||||
and b.store.get_time("last_failed") is None)
|
||||
slot = (T0 + timedelta(days=1)).replace(hour=19, minute=5)
|
||||
check("...then B, with its SoC, takes the slot as usual",
|
||||
arbitrate([a, b], slot) == ["", ""] and b.wants_start(slot)
|
||||
and not a.wants_start(slot))
|
||||
b.force_start(slot)
|
||||
rb = b.tick(slot + 5 * MIN, 50.0)
|
||||
check("...and B's drain runs at the drain rate",
|
||||
rb.phase == DRAIN and rb.setpoint_w == CFG.discharge_w)
|
||||
# the other way: B charges with no SoC, A has a SoC
|
||||
a = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a")
|
||||
b = Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b")
|
||||
b.force_start(T0)
|
||||
b.tick(T0, 11.0)
|
||||
run(b, T0, 5, 97.0)
|
||||
a_alone = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a")
|
||||
same, t = True, T0 + 10 * MIN
|
||||
while t < T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 30):
|
||||
plan = arbitrate([a, b], t)
|
||||
rb = b.tick(t, None, blocked_by=plan[1])
|
||||
ra = a.tick(t, 60.0, blocked_by=plan[0])
|
||||
ra0 = a_alone.tick(t, 60.0, blocked_by=plan[0])
|
||||
same = same and (ra.phase, ra.setpoint_w, ra.deferred) == \
|
||||
(ra0.phase, ra0.setpoint_w, ra0.deferred)
|
||||
if rb.phase != CHARGE:
|
||||
break
|
||||
t += 5 * MIN
|
||||
check("B charges with no SoC (last 97): A (SoC 60) is unchanged tick by tick",
|
||||
same)
|
||||
check("...B ends as done (HOLD), A untouched, no failure on either",
|
||||
rb.phase == HOLD and rb.failed == ""
|
||||
and b.store.get_time("last_failed") is None
|
||||
and a.store.get_time("last_failed") is None and a.phase == IDLE)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
sys.exit(1)
|
||||
print("all passed")
|
||||
@@ -0,0 +1,299 @@
|
||||
"""MAINT-15: the HOLD ends on time with no SoC reading.
|
||||
`python3 test_maint15.py`
|
||||
|
||||
Graded here: a HOLD that loses its SoC (at the start, mid-hold, just before
|
||||
hold_min) ends on time, writes last_completed and says the COMPLETE line; SoC
|
||||
back mid-hold changes nothing; HOLD stays 0 W; one pack's loss leaves the other
|
||||
pack alone; a restart in HOLD with no SoC and an old state file.
|
||||
See DECISIONS/MAINT-15-hold-ends-without-soc.md.
|
||||
|
||||
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
|
||||
"""
|
||||
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.maintenance import (
|
||||
CHARGE, DRAIN, HOLD, IDLE, NOSOC_NOTE_MIN, MaintConfig, Maintenance,
|
||||
)
|
||||
from app.store import DEFAULTS, Store
|
||||
|
||||
UTC = timezone.utc
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=120)
|
||||
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC)
|
||||
MIN = timedelta(minutes=1)
|
||||
|
||||
|
||||
class Mem:
|
||||
def __init__(self, data=None):
|
||||
self.data = dict(DEFAULTS, **(data or {}))
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def set_time(self, k, when):
|
||||
self.data[k] = when.astimezone(UTC).isoformat() if when else None
|
||||
|
||||
def get_time(self, k):
|
||||
raw = self.data.get(k)
|
||||
return datetime.fromisoformat(raw) if raw else None
|
||||
|
||||
def save(self):
|
||||
pass
|
||||
|
||||
|
||||
def in_drain(store=None, unit=None, at=T0):
|
||||
m = Maintenance(CFG, store or Mem(), unit=unit, name=unit or "")
|
||||
m.force_start(at)
|
||||
assert m.phase == DRAIN
|
||||
return m
|
||||
|
||||
|
||||
def in_charge(store=None, unit=None, at=T0):
|
||||
m = in_drain(store, unit, at)
|
||||
m.tick(at, 11.0)
|
||||
assert m.phase == CHARGE
|
||||
return m
|
||||
|
||||
|
||||
def run(m, start, minutes, soc, gate=True, step=1):
|
||||
"""Tick every `step` min; returns (last result, end time, first result that
|
||||
is not the starting phase with its time, all events)."""
|
||||
ph, t, res, out, ev = m.phase, start, None, None, []
|
||||
for i in range(0, minutes, step):
|
||||
t = start + i * MIN
|
||||
s = soc(i) if callable(soc) else soc
|
||||
res = m.tick(t, s, gate_open=gate)
|
||||
ev += res.events
|
||||
if out is None and res.phase != ph:
|
||||
out = (res, t)
|
||||
break
|
||||
return res, start + minutes * MIN, out, ev
|
||||
|
||||
|
||||
|
||||
HOLD_MIN = CFG.hold_min
|
||||
|
||||
|
||||
def in_hold(store=None, unit=None, at=T0):
|
||||
"""A pack in HOLD that started at `at` + 1 min (charge counted as done)."""
|
||||
m = in_charge(store, unit, at)
|
||||
m.tick(at + MIN, 100.0)
|
||||
assert m.phase == HOLD
|
||||
return m
|
||||
|
||||
|
||||
H0 = T0 + MIN # the hold's start
|
||||
print("1. SoC lost in HOLD: the hold ends on time")
|
||||
for label, lost_at in (("at the start", 0), ("mid-hold", 60),
|
||||
("just before hold_min", HOLD_MIN - 1)):
|
||||
m = in_hold()
|
||||
run(m, H0, lost_at, 100.0) if lost_at else None
|
||||
res, _, out, ev = run(m, H0 + lost_at * MIN, HOLD_MIN + 5 - lost_at, None)
|
||||
check(f"lost {label}: ends at hold_min, to IDLE, not failed",
|
||||
out is not None and out[0].phase == IDLE and out[0].failed == ""
|
||||
and out[1] == H0 + HOLD_MIN * MIN)
|
||||
check("...last_completed is written at that time",
|
||||
m.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
check("...the same COMPLETE line, once, and no last_failed",
|
||||
sum("cycle COMPLETE (120 min hold)" in e for e in ev) == 1
|
||||
and m.store.get_time("last_failed") is None)
|
||||
check("...the pack is idle and hands the setpoint back",
|
||||
m.phase == IDLE and not out[0].owns_setpoint)
|
||||
|
||||
m = in_hold()
|
||||
res, _, out, _ = run(m, H0, HOLD_MIN - 1, None)
|
||||
check("before hold_min: still HOLD at 0 W, owned, nothing written",
|
||||
out is None and res.phase == HOLD and res.owns_setpoint
|
||||
and res.setpoint_w == 0.0 and m.store.get_time("last_completed") is None)
|
||||
check("...the pack is not due again (next due date moved after the end)",
|
||||
(run(m, H0 + (HOLD_MIN - 1) * MIN, 3, None), m.due(H0 + 130 * MIN))[1] is False)
|
||||
|
||||
print("2. the text")
|
||||
m = in_hold()
|
||||
_, _, out, ev = run(m, H0, HOLD_MIN + 5, None)
|
||||
note = [e for e in ev if "no battery level for" in e]
|
||||
check("one 15 min line, saying the hold ends at its normal time",
|
||||
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0]
|
||||
and f"{NOSOC_NOTE_MIN} min" in note[0])
|
||||
check("...and the other events are the one COMPLETE line only", len(ev) == 2)
|
||||
m = in_hold()
|
||||
_, _, _, ev = run(m, H0, NOSOC_NOTE_MIN - 2, None)
|
||||
check("under the threshold the line is not said", ev == [])
|
||||
|
||||
print("3. SoC comes back mid-hold")
|
||||
ends = {}
|
||||
for label, soc in (("no SoC", lambda i: None if i < 40 else 100.0),
|
||||
("SoC the whole time", 100.0),
|
||||
("a low SoC after the gap", lambda i: None if i < 40 else 55.0)):
|
||||
m = in_hold()
|
||||
res, _, out, ev = run(m, H0, HOLD_MIN + 5, soc)
|
||||
ends[label] = (out[1], m.store.get_time("last_completed")) if out else None
|
||||
check(f"{label}: ends at hold_min", out is not None
|
||||
and out[1] == H0 + HOLD_MIN * MIN)
|
||||
check("...the end time is the same with or without the gap",
|
||||
len(set(ends.values())) == 1)
|
||||
m = in_hold()
|
||||
run(m, H0, 40, None)
|
||||
res, _, out, _ = run(m, H0 + 40 * MIN, 30, 100.0)
|
||||
check("back mid-hold: still HOLD at 0 W until the time is up",
|
||||
out is None and res.phase == HOLD and res.setpoint_w == 0.0)
|
||||
|
||||
print("4. restart in HOLD with no SoC")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
path = os.path.join(d, "state.json")
|
||||
m = Maintenance(CFG, Store(path))
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
m.tick(H0, 100.0)
|
||||
run(m, H0, 50, None)
|
||||
m2 = Maintenance(CFG, Store(path))
|
||||
r = m2.tick(H0 + 51 * MIN, None)
|
||||
check("a fresh process reads HOLD and holds 0 W", m2.phase == HOLD
|
||||
and r.phase == HOLD and r.owns_setpoint and r.setpoint_w == 0.0)
|
||||
res, _, out, _ = run(m2, H0 + 52 * MIN, HOLD_MIN, None)
|
||||
check("...and the hold ends at hold_min from the hold start, not the restart",
|
||||
out and out[0].phase == IDLE and out[1] == H0 + HOLD_MIN * MIN
|
||||
and m2.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
import json
|
||||
old = {"phase": "hold", "phase_started": H0.isoformat(),
|
||||
"last_completed": None, "last_start_attempt": None, "auto": True}
|
||||
p2 = os.path.join(d, "old.json")
|
||||
json.dump(old, open(p2, "w"))
|
||||
mo = Maintenance(CFG, Store(p2))
|
||||
r = mo.tick(H0 + 10 * MIN, None)
|
||||
check("an old state file in HOLD loads and holds 0 W", mo.phase == HOLD
|
||||
and r.setpoint_w == 0.0)
|
||||
res, _, out, _ = run(mo, H0 + 11 * MIN, HOLD_MIN, None)
|
||||
check("...and ends on time, writing last_completed",
|
||||
out and out[1] == H0 + HOLD_MIN * MIN
|
||||
and mo.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
mr = Maintenance(CFG, Store(p2))
|
||||
check("...the written file reloads as a finished cycle",
|
||||
mr.phase == IDLE and mr.store.get_time("last_completed") is not None)
|
||||
|
||||
print("5. two packs")
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a_ok, b_ok = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
for x in (a, a_ok):
|
||||
x.force_start(T0)
|
||||
x.tick(T0, 11.0)
|
||||
x.tick(H0, 100.0)
|
||||
# B is idle; A's hold loses its SoC (twin site: A keeps it)
|
||||
same, a_end = True, None
|
||||
for i in range(0, HOLD_MIN + 10):
|
||||
t = H0 + i * MIN
|
||||
ra = a.tick(t, None)
|
||||
rb = b.tick(t, 60.0)
|
||||
ra2 = a_ok.tick(t, 100.0)
|
||||
rb2 = b_ok.tick(t, 60.0)
|
||||
same = same and (rb.phase, rb.owns_setpoint, rb.setpoint_w) == \
|
||||
(rb2.phase, rb2.owns_setpoint, rb2.setpoint_w) and b.phase == b_ok.phase
|
||||
if a_end is None and a.phase == IDLE:
|
||||
a_end = t
|
||||
check("A loses SoC in HOLD: A ends on time (as the twin with a reading)",
|
||||
a_end == H0 + HOLD_MIN * MIN and a_ok.phase == IDLE
|
||||
and a.store.get_time("last_completed") == a_ok.store.get_time("last_completed"))
|
||||
check("...B is the same as in the twin site where A kept its SoC", same)
|
||||
# B in its own HOLD with SoC, A in HOLD without
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a.force_start(T0); a.tick(T0, 11.0); a.tick(H0, 100.0)
|
||||
b_start = H0 + 30 * MIN
|
||||
b.force_start(b_start - MIN); b.tick(b_start - MIN, 11.0); b.tick(b_start, 100.0)
|
||||
b_end = None
|
||||
for i in range(0, HOLD_MIN + 40):
|
||||
t = H0 + i * MIN
|
||||
a.tick(t, None)
|
||||
if t >= b_start:
|
||||
b.tick(t, 100.0)
|
||||
if b_end is None and b.phase == IDLE:
|
||||
b_end = t
|
||||
check("B (SoC present) ends at its own hold_min, A's loss changes nothing",
|
||||
b_end == b_start + HOLD_MIN * MIN and a.phase == IDLE
|
||||
and b.store.get_time("last_completed") == b_start + HOLD_MIN * MIN)
|
||||
check("...A's end is not delayed by B", a.store.get_time("last_completed")
|
||||
== H0 + HOLD_MIN * MIN)
|
||||
|
||||
print("6. other phases unchanged")
|
||||
m = in_drain()
|
||||
res, _, out, _ = run(m, T0, 60, None)
|
||||
check("DRAIN with no SoC still holds 0 W and does not end", out is None
|
||||
and res.phase == DRAIN and res.setpoint_w == 0.0)
|
||||
m = in_charge()
|
||||
res, _, out, _ = run(m, T0, 600, None)
|
||||
check("CHARGE with no SoC still keeps charging", out is None
|
||||
and res.phase == CHARGE and res.charge_only)
|
||||
|
||||
|
||||
def old_hold_branch(phase_started, last_completed, now, hold_min):
|
||||
"""FROZEN copy of release/1.0 (db9e231) HOLD branch of step(), with a
|
||||
reading: returns (phase, owns_setpoint, setpoint_w, events,
|
||||
last_completed). Kept as a reference for the differential check below."""
|
||||
elapsed = (now - phase_started).total_seconds() / 60.0
|
||||
if elapsed >= hold_min:
|
||||
return (IDLE, False, None,
|
||||
[f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop"], now)
|
||||
return (HOLD, True, 0.0, [], last_completed)
|
||||
|
||||
|
||||
print("7. with a reading: the new HOLD against the frozen release/1.0 branch")
|
||||
for hm in (0, 5, 60, 120):
|
||||
cfg = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=hm)
|
||||
m = Maintenance(cfg, Mem())
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
m.tick(H0, 100.0)
|
||||
started, last, same, end = H0, None, True, None
|
||||
for i in range(0, hm + 15):
|
||||
t = H0 + i * MIN
|
||||
if m.phase != HOLD:
|
||||
break
|
||||
want = old_hold_branch(started, last, t, hm)
|
||||
r = m.tick(t, 100.0 - (i % 3))
|
||||
got = (r.phase, r.owns_setpoint, r.setpoint_w, r.events,
|
||||
m.store.get_time("last_completed"))
|
||||
same = same and got == want
|
||||
last = want[4]
|
||||
if r.phase == IDLE:
|
||||
end = t
|
||||
check(f"hold_min {hm}: every tick identical (phase, owns, W, events, "
|
||||
"last_completed)", same)
|
||||
check("...ends at hold_min, last_completed = that tick, one COMPLETE line",
|
||||
end == H0 + hm * MIN and m.store.get_time("last_completed") == end
|
||||
and m.phase == IDLE)
|
||||
|
||||
m = in_hold()
|
||||
res, _, out, ev = run(m, H0, HOLD_MIN + 5, 100.0)
|
||||
check("HOLD with a reading: 0 W until the end, then IDLE at hold_min",
|
||||
out is not None and out[1] == H0 + HOLD_MIN * MIN and out[0].phase == IDLE)
|
||||
check("...last_completed is that tick and the COMPLETE line is said once",
|
||||
m.store.get_time("last_completed") == H0 + HOLD_MIN * MIN
|
||||
and ev == ["maintenance: cycle COMPLETE (120 min hold) "
|
||||
"- handing back to the loop"])
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED:")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
sys.exit(1)
|
||||
print("all ok")
|
||||
@@ -122,7 +122,8 @@ m = Maintenance(cfg, FakeStore())
|
||||
m.force_start(t0)
|
||||
r = m.tick(t0 + timedelta(minutes=5), soc=None)
|
||||
check("no SoC: holds the phase rather than guessing", r.phase == DRAIN)
|
||||
check("no SoC: still commands the drain rate", r.setpoint_w == 2500)
|
||||
check("no SoC: MAINT-14 the drain holds at 0 W, never discharges",
|
||||
r.owns_setpoint and r.setpoint_w == 0.0)
|
||||
|
||||
m = Maintenance(cfg, FakeStore())
|
||||
m.store.set("phase", "banana")
|
||||
|
||||
@@ -0,0 +1,307 @@
|
||||
"""Runnable check for SAFETY-107: a refusal held while another writer has the
|
||||
wire is learned once. `python3 test_safety107.py`
|
||||
|
||||
A full pack under a maintenance charge in a cheap window took no charge. At
|
||||
one inverter SAFETY-52's "another writer" end then fired every cycle, and
|
||||
compute() learned the refusal again in the same cycle: "BATTERY REFUSES" and
|
||||
"BATTERY REFUSES ENDED: another writer" each second on the rig (MAINT-13 F5).
|
||||
Now another writer ends a refusal only if compute(), judging it afresh
|
||||
against that writer's ask, no longer finds it. DECISIONS/SAFETY-107.
|
||||
|
||||
Drives the REAL Controller (read_inputs + cycle) on opt11_identity's rig.
|
||||
1. The card's case: 15 min of a full pack under a maintenance charge, N=1
|
||||
and N=2, at a 1, 2 and 5 s meter: at most 2 refusal lines, held throughout.
|
||||
2. Other writers: a trade and the peak guard over a battery that gives
|
||||
nothing. One episode each, no flap.
|
||||
3. A refusal still ends: a different writer really takes over, the battery
|
||||
delivers again, a writer asks the other way, stop. The probe clock.
|
||||
|
||||
4. Not covered, pinned: a perfectly flat reading under a writer.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in DECISIONS/SAFETY-107.
|
||||
"""
|
||||
|
||||
import functools
|
||||
import logging
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety79_identity as s79 # noqa: E402
|
||||
import app.main as app_main # noqa: E402
|
||||
from app import control # noqa: E402
|
||||
from app.arbiter import Claim, P_ARBITRAGE # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from named_absence import nth, present # noqa: E402
|
||||
|
||||
fails = []
|
||||
QUARTER = 900.0
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def run(n=1, *, plant, house, dur=QUARTER, tick=5.0, maint=True,
|
||||
cheap=lambda c, t: True, trade=lambda t: None, p1=False, cap=2500,
|
||||
auto=lambda t: True):
|
||||
"""Rows (t, commands, site target, loop reason, refused, refused_at,
|
||||
unit refusals) and every action-log line as (t, line, hint).
|
||||
|
||||
`plant(u, t, cmd)` is battery u's reading. `cheap(c, t)` opens the cheap
|
||||
window. `trade(t)` is a SET claim at P_ARBITRAGE added to the claim list
|
||||
(a writer above the loop), or None."""
|
||||
log, rows, now = [], [], [0.0]
|
||||
real_power, real_tick = rig._Hass.power, rig.TICK
|
||||
real_log, real_resolve, real_c = (Controller.log_event, app_main.resolve,
|
||||
rig.Controller)
|
||||
|
||||
def power(self, u):
|
||||
return float(plant(u, self.t, self.cmd[u]))
|
||||
|
||||
def log_event(self, msg, hint=None):
|
||||
log.append((now[0], msg, hint))
|
||||
return real_log(self, msg, hint)
|
||||
|
||||
def resolve(claims, **kw):
|
||||
v = trade(now[0])
|
||||
if v is not None:
|
||||
claims.append(Claim.set("arbitrage", P_ARBITRAGE, v, "trade"))
|
||||
return real_resolve(claims, **kw)
|
||||
|
||||
def before(c, t):
|
||||
now[0] = t
|
||||
if not getattr(c.hass, "_s107", False):
|
||||
read = c.hass.number
|
||||
|
||||
async def number(e, invert=False):
|
||||
if e == "sensor.pnow":
|
||||
return 0.05 if cheap(c, c.hass.t) else 0.30
|
||||
if e == "sensor.pavg":
|
||||
return 0.20
|
||||
return await read(e, invert)
|
||||
c.hass.number, c.hass._s107 = number, True
|
||||
if p1:
|
||||
s79._feed(c, t)
|
||||
c.auto = auto(t)
|
||||
|
||||
def on_cycle(c, t):
|
||||
rows.append((t, tuple(c.hass.cmd[u] for u in "ab"[:n]), c.target,
|
||||
c.loop_reason, c.batt_refused, c.batt_refused_at,
|
||||
tuple(i.refused for i in c.inverters)))
|
||||
|
||||
extra = {"price_now_entity": "sensor.pnow",
|
||||
"price_avg_entity": "sensor.pavg"}
|
||||
if maint:
|
||||
extra.update({"maintenance_enabled": True,
|
||||
"maintenance_start_hour": 11,
|
||||
"maintenance_charge_w": 2000})
|
||||
if p1:
|
||||
extra.update(s79.P1, peak_cap_w=cap)
|
||||
db = os.path.join(tempfile.mkdtemp(prefix="s107-"), "tariff.db")
|
||||
rig._Hass.power, rig.TICK = power, tick
|
||||
Controller.log_event, app_main.resolve = log_event, resolve
|
||||
rig.Controller = functools.partial(real_c, peak_db_path=db)
|
||||
try:
|
||||
_, c = rig.run(n, extra=extra, dur=dur, load=house,
|
||||
soc=lambda u, t: 50.0, cut=lambda u, t: False,
|
||||
before=before, on_cycle=on_cycle,
|
||||
store=s79.store_charging(n) if maint else rig._Store())
|
||||
finally:
|
||||
rig._Hass.power, rig.TICK = real_power, real_tick
|
||||
Controller.log_event, app_main.resolve = real_log, real_resolve
|
||||
rig.Controller = real_c
|
||||
return rows, log, c
|
||||
|
||||
|
||||
def full_a(u, t, cmd):
|
||||
"""A takes no charge (a full pack), its reading jittering by a few watts
|
||||
as a real one does; B follows."""
|
||||
return -1.0 - int(t) % 3 if u == "a" and cmd < 0 else round(cmd)
|
||||
|
||||
|
||||
def flat_a(u, t, cmd):
|
||||
"""`full_a` with a perfectly flat reading (the stale-reading gate trips)."""
|
||||
return -1.0 if u == "a" and cmd < 0 else round(cmd)
|
||||
|
||||
|
||||
def empty_a(u, t, cmd):
|
||||
"""A gives nothing (an empty pack), its reading jittering by a few watts
|
||||
(SAFETY-73's jitter shape, so the stale-reading gate stays out of it);
|
||||
B follows."""
|
||||
return -4.0 - int(t) % 3 if u == "a" and cmd >= -4.0 else round(cmd)
|
||||
|
||||
|
||||
def lines(log, word="REFUSES"):
|
||||
return [x for x in log if word in x[1]]
|
||||
|
||||
|
||||
def ends(log):
|
||||
return [x for x in log if "REFUSES ENDED" in x[1]]
|
||||
|
||||
|
||||
def refused(r):
|
||||
"""Row r holds a refusal (site at N=1, any unit at N>1)."""
|
||||
return bool(r[4]) or any(r[6])
|
||||
|
||||
|
||||
def held_from(rows):
|
||||
"""True when, once learned, the refusal is held on every later row."""
|
||||
first = next((k for k, r in enumerate(rows) if refused(r)), None)
|
||||
return first is not None and all(refused(r) for r in rows[first:])
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print("1. the card: a full pack under a maintenance charge, 15 min")
|
||||
# ==============================================================================
|
||||
for n, tick, house in ((n, k, h) for n in (1, 2) for k in (1.0, 2.0, 5.0)
|
||||
for h in (800.0, -1500.0)):
|
||||
rows, log, c = run(n, plant=full_a, house=lambda t: house, tick=tick)
|
||||
ref = lines(log)
|
||||
tag = f"N={n}, {tick:.0f} s meter, house {house:+.0f} W"
|
||||
print(f" {tag}: {len(ref)} refusal line(s): "
|
||||
+ " / ".join(x[1][:60] for x in ref))
|
||||
check(f"{tag}: at most 2 refusal lines in 15 min (rig: 548 + 548)",
|
||||
1 <= len(ref) <= 2)
|
||||
check(f"{tag}: no end line", not ends(log))
|
||||
check(f"{tag}: learned once and held to the end", held_from(rows))
|
||||
# N=1: the charge's ceiling stays on the wire. N=2: SAFETY-73 closes A
|
||||
# in the refused direction, as before.
|
||||
check(f"{tag}: still in its charge, the wire as before",
|
||||
c.maints[0].phase == "charge"
|
||||
and all(r[1][0] == (-2000.0 if n == 1 else 0.0)
|
||||
for r in rows[-10:]))
|
||||
# The hint under the buttons is set at most once for the refusal.
|
||||
check(f"{tag}: the refusal hint is set once",
|
||||
sum(1 for x in ref if x[2] is not None) == 1)
|
||||
|
||||
# The probe clock: while the charge holds the wire no probe is tried (the
|
||||
# loop's ask is not on the wire), so the action log stays quiet.
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0, dur=3600.0)
|
||||
check("N=1, an hour: still one line, no probe tried under the charge",
|
||||
len(lines(log)) == 1
|
||||
and not any(r[3] == control.PROBING for r in rows))
|
||||
|
||||
# ==============================================================================
|
||||
print("\n2. other writers: a trade and the peak guard, no flap")
|
||||
# ==============================================================================
|
||||
# A trade (a SET above the loop) asks a full pack to charge for 15 min.
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0, maint=False,
|
||||
trade=lambda t: -1500.0)
|
||||
print(f" trade into a full pack: {len(lines(log))} line(s)")
|
||||
check("a trade into a full pack: learned once, held, no end",
|
||||
len(lines(log)) == 1 and not ends(log) and held_from(rows))
|
||||
# The peak guard asks an empty pack to give while the house is over the limit.
|
||||
rows, log, c = run(1, plant=empty_a, house=lambda t: 4500.0, maint=False,
|
||||
p1=True)
|
||||
print(f" peak guard on an empty pack: {len(lines(log))} line(s), "
|
||||
f"guard floor {c.peak_guard.floor_w if c.peak_guard else None}")
|
||||
check("the peak guard on an empty pack: the guard holds the wire",
|
||||
c.peak_guard is not None and c.peak_guard.engaged)
|
||||
check("the peak guard on an empty pack: at most 2 lines, held to the end",
|
||||
1 <= len(lines(log)) <= 2 and held_from(rows))
|
||||
|
||||
# ==============================================================================
|
||||
print("\n3. a refusal still ends")
|
||||
# ==============================================================================
|
||||
# a. Learned by the loop on an empty pack; at 300 s a trade really takes the
|
||||
# wire and asks it to give 2000 W. The refusal was learned against the
|
||||
# loop's ask: it ends, then is learned against the trade, once.
|
||||
rows, log, _ = run(1, plant=empty_a, house=lambda t: 2000.0, maint=False,
|
||||
trade=lambda t: 2000.0 if 300.0 <= t < 900.0 else None,
|
||||
dur=1200.0)
|
||||
e = ends(log)
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
check("a different writer takes over: the refusal ends, 'another writer'",
|
||||
len(e) == 1 and "another writer" in e[0][1] and 300.0 < e[0][0] < 320.0)
|
||||
check("...and is learned again against the trade, once, and held",
|
||||
len(lines(log)) == 3 and held_from([r for r in rows if r[0] > 400.0]))
|
||||
check("...and the loop keeps it when the trade leaves (no line)",
|
||||
all(x[0] < 900.0 for x in lines(log)) and refused(nth(rows, -1)))
|
||||
# The writer asks the other way, which the empty pack takes.
|
||||
rows, log, _ = run(1, plant=empty_a, house=lambda t: 2000.0, maint=False,
|
||||
trade=lambda t: -1500.0 if t >= 300.0 else None)
|
||||
e = ends(log)
|
||||
check("a writer that asks the other way ends it ('another writer')",
|
||||
len(e) == 1 and "another writer" in e[0][1] and present(nth(rows, -1))
|
||||
and not refused(nth(rows, -1)))
|
||||
# b. The full pack starts taking charge again under the same writer.
|
||||
rows, log, _ = run(1, plant=lambda u, t, cmd: (
|
||||
round(cmd) if t >= 400.0 else full_a(u, t, cmd)), house=lambda t: 800.0)
|
||||
e = ends(log)
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
check("the battery takes charge again: the refusal ends once, on its reading",
|
||||
len(e) == 1 and "the battery gives power" in e[0][1]
|
||||
and 400.0 <= e[0][0] < 430.0 and present(nth(rows, -1))
|
||||
and not refused(nth(rows, -1)))
|
||||
# c. Stop and start still end it.
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0,
|
||||
auto=lambda t: not 500.0 <= t < 520.0)
|
||||
e = ends(log)
|
||||
check("stopping control still ends it", any("control stopped" in x[1]
|
||||
for x in e))
|
||||
# d. The probe clock. Learned under the charge; the cheap window closes when
|
||||
# the refusal is 910 s old, and the loop holds the wire (a surplus, so it
|
||||
# wants to charge). The first probe is a full PROBE_EVERY_S after the
|
||||
# window closed, as before: never at once.
|
||||
close = [None]
|
||||
|
||||
|
||||
def window(c, t):
|
||||
if close[0] is None and c.batt_refused:
|
||||
close[0] = t + 910.0
|
||||
return close[0] is None or t < close[0]
|
||||
|
||||
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: -1500.0, cheap=window,
|
||||
dur=3000.0)
|
||||
probes = [r[0] for r in rows if r[3] == control.PROBING]
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
print(f" window closed at {close[0]} s, first probe at "
|
||||
f"{probes[0] if probes else None} s")
|
||||
check("the refusal carries over to the loop with no line",
|
||||
len(lines(log)) == 1 and held_from(rows))
|
||||
check("the first probe after the writer left comes PROBE_EVERY_S later",
|
||||
close[0] is not None and bool(probes)
|
||||
and probes[0] >= close[0] + control.PROBE_EVERY_S - 10.0)
|
||||
# e. A writer turns round on a dead pack with no gap. The evidence restarts
|
||||
# on the new sign (SAFETY-94), so the old refusal ends at once and the
|
||||
# other way is learned once, ~12 cycles later.
|
||||
rows, log, _ = run(1, plant=lambda u, t, cmd: (
|
||||
-2.0 - int(t) % 3 if u == "a" else round(cmd)), house=lambda t: 2000.0,
|
||||
maint=False, trade=lambda t: 2000.0 if t < 300.0 else -2000.0)
|
||||
e = ends(log)
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
check("a writer turns round on a dead pack: one end, then the other way",
|
||||
len(lines(log)) == 3 and len(e) == 1 and 300.0 < e[0][0] < 400.0
|
||||
and present(nth(rows, -1)) and nth(rows, -1)[4] == -1)
|
||||
|
||||
# ==============================================================================
|
||||
print("\n4. not covered: a perfectly flat reading under a writer")
|
||||
# ==============================================================================
|
||||
# The stale-reading gate trips on a flat reading while the command moves,
|
||||
# stops the site and seeds the refusal (SAFETY-52 decision 3). After the stop
|
||||
# the writer's ask comes back fresh, compute() has no saturation history
|
||||
# against it yet, so the refusal ends at the first cycle and the next trip
|
||||
# seeds it again: one pair per gate cycle, as on release/1.0 (the commands
|
||||
# are the same; DECISIONS/SAFETY-107 "Not covered"). Pinned so a change shows.
|
||||
rows, log, _ = run(1, plant=flat_a, house=lambda t: -1500.0)
|
||||
trips = len(lines(log, "STALE inverter"))
|
||||
print(f" flat reading, house -1500 W: {trips} gate trips, "
|
||||
f"{len(lines(log))} refusal lines in 15 min")
|
||||
check("flat reading: no per-cycle flap, at most one pair per gate trip",
|
||||
trips >= 1 and len(lines(log)) <= 2 * trips)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all SAFETY-107 checks passed")
|
||||
Reference in New Issue
Block a user