glenn schrooyenandClaude Opus 5.5 6028e21298 SAFETY-34: re-assert latched alarms, because a Core restart keeps the add-on
checks / unit (pull_request) Successful in 8m55s
infra-pin / fresh (pull_request) Successful in 1s
A Core-only restart wipes persistent_notification and does NOT restart the
add-on (measured on TEST-23: the add-on's SAFETY-31 card was gone 4 min after
`docker restart test23-ha`, add-on StartedAt unchanged). The latched SAFETY-31
and SAFETY-42 cards were re-raised only on add-on start, so they stayed gone.

They are now re-asserted every REANNOUNCE_S = 300 s while tripped (same
notification_id, so it replaces). test_watchdog part 6 and test_delivery part
8b grade it with the same process across the "restart"; red on the old code.
The docstrings that said the add-on restarts with HA are corrected.
Record: goodwe docs/DECISIONS.md, SAFETY-34 D4.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-26 12:37:47 +02:00
admin fe132515fe Merge pull request 'CI: bump infra pin to a1d0618 (admin/goodwe#57, TOOL-9)' (#127) from pin-bump-a1d0618 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 20:52:59 +02:00
glenn schrooyenandClaude Opus 5.5 00e9a7b4e1 CI: bump infra pin to a1d0618 (admin/goodwe#57, TOOL-9)
checks / unit (pull_request) Successful in 8m46s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 20:42:44 +02:00
admin 82f032e8cf Merge pull request 'TOOL-9: pin checks print FAIL under pipefail; job tokens via header' (#126) from TOOL-9 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 20:39:47 +02:00
glenn schrooyenandClaude Opus 5.5 b963153de6 Restore .gitea/infra-pin (revert the TOOL-9 proof throwaway)
checks / unit (pull_request) Successful in 8m45s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 19:20:19 +02:00
glenn schrooyenandClaude Opus 5.5 a2c571b20e THROWAWAY (TOOL-9 proof, reverted next): remove .gitea/infra-pin
checks / unit (pull_request) Failing after 3s
infra-pin / fresh (pull_request) Failing after 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 19:08:22 +02:00
glenn schrooyenandClaude Opus 5.5 550bd6fa52 TOOL-9: pin checks print their FAIL line under pipefail; job tokens via header
checks / unit (pull_request) Failing after 3s
infra-pin / fresh (pull_request) Successful in 1s
A missing or comment-only .gitea/infra-pin now ends on the workflow's own
FAIL line instead of git's `fatal: path ... does not exist` (still red). Every
x-access-token remote URL becomes an env-set Authorization header, so no
token lands in .git/config or argv; the pin workflows' temp dir is removed
by an EXIT trap, also on failure.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 19:07:34 +02:00
admin 6a8a5ffa27 Merge pull request 'CI-12: CI grades test_freeze.py against the real hwsim at a pinned admin/goodwe' (#125) from CI-12 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 18:19:43 +02:00
glenn schrooyenandClaude Opus 5.5 8ff42ea85d CI-12: .gitea/infra-pin to admin/goodwe release/1.0 HEAD (2d026df, goodwe#56 merged)
checks / unit (pull_request) Successful in 8m42s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-25 18:10:28 +02:00
glenn schrooyenandClaude Opus 5.5 841424463a CI-12 review: INFRA_READ_TOKEN via an env-set header, not a remote URL
checks / unit (pull_request) Successful in 8m42s
infra-pin / fresh (pull_request) Successful in 1s
The long-lived token no longer lands in $WS/goodwe/.git/config (mounted into
the tests' container, left behind by a failed job) or in git's argv. A missing
secret (fork PR) fails with its own message. README: addon-pin is not re-run
after a bump.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-25 18:01:15 +02:00
glenn schrooyenandClaude Opus 5.5 c63eda0b0f CI-12: restore .gitea/infra-pin to admin/goodwe release/1.0 HEAD (56a933e)
checks / unit (pull_request) Successful in 8m43s
infra-pin / fresh (pull_request) Successful in 1s
This reverts commit 54cc5263fb (the proof-2 throwaway).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 17:45:36 +02:00
glenn schrooyenandClaude Opus 5.5 54cc5263fb THROWAWAY (CI-12 proof 2): pin one release/1.0 merge behind (d84ac01); reverted next
checks / unit (pull_request) Successful in 8m43s
infra-pin / fresh (pull_request) Failing after 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 17:36:36 +02:00
glenn schrooyenandClaude Opus 5.5 c493a6d67a CI-12: test_tariff.py no longer says CI cannot see the infra repo
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 8m47s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 17:27:06 +02:00
glenn schrooyenandClaude Opus 5.5 d0891a6bca CI-12: .gitea/infra-pin to admin/goodwe release/1.0 HEAD (56a933e), restoring the proof pin
checks / unit (pull_request) Failing after 3s
infra-pin / fresh (pull_request) Failing after 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 16:10:47 +02:00
glenn schrooyenandClaude Opus 5.5 fe80047235 CI-12 round 2: INFRA_READ_TOKEN for admin/goodwe; the pin tracks release/1.0
checks / unit (pull_request) Failing after 3s
infra-pin / fresh (pull_request) Failing after 1s
- checks.yml's infra checkout and infra-pin.yml's admin/goodwe ls-remote use
  the INFRA_READ_TOKEN secret; the self fetch keeps GITHUB_TOKEN.
- infra-pin.yml compares against admin/goodwe refs/heads/release/1.0; STALE
  message, comments and README follow.
- test_control.py / test_alloc.py: drop the claim that CI cannot reach
  admin/goodwe.
- .gitea/infra-pin is DELIBERATELY one release/1.0 merge behind (d84ac01) for
  the "infra-pin / fresh goes red" proof; the next commit sets it to HEAD.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 16:08:55 +02:00
adminandClaude Opus 5.5 6e3399322a CI-12: CI grades test_freeze.py against the real hwsim at a pinned admin/goodwe
infra-pin / fresh (pull_request) Failing after 1s
checks / unit (pull_request) Failing after 2s
- .gitea/infra-pin: the one place the admin/goodwe commit is pinned.
- checks.yml: checks out admin/goodwe at the pin as the sibling test_freeze.py
  looks for; any failure fails the job. Tests run with GOODWE_REQUIRE_HWSIM=1,
  and `CI: ` lines are echoed on PASS so the log shows which transport ran.
- test_freeze.py: GOODWE_REQUIRE_HWSIM refuses the stub; a local stub run
  prints a STUB USED line.
- infra-pin.yml: a separate, non-required check that goes red naming both
  SHAs when admin/goodwe master has moved past the pin.
- README: when and how to bump the pin.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 01:57:04 +02:00
admin 16c796fa30 Merge pull request 'TEL-14: PV sign declared per entity (pv_invert_entities)' (#124) from TEL-14-pv-sign into release/1.0 2026-09-25 01:30:33 +02:00
admin 20260e86ec Merge pull request 'DOC-5: tell installers to turn on the Supervisor Watchdog' (#123) from DOC-5-watchdog into release/1.0 2026-09-25 01:17:35 +02:00
adminandClaude Opus 5.5 7fa045af85 TEL-14 N1: trim DECISIONS (drop probe transcript, §1 to the reason), move the mutation ledger there with M2/M5
checks / unit (pull_request) Successful in 8m44s
test_pv.py part 11 now prints a one-line pointer instead of the 12-row table.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 01:11:40 +02:00
adminandClaude Opus 5.5 93f349a6af TEL-14 B1: pin stray caution on the reported case and whitespace normalisation end to end
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 01:10:13 +02:00
glenn schrooyenandClaude Opus 5.5 7559d21eda TEL-14: PV sign declared per entity (pv_invert_entities)
checks / unit (pull_request) Successful in 8m39s
Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive
for consumption and negative for production. `pv_invert_entities` lists the
ones to flip; the flip is applied per member inside pv.total(), before the sum,
so the MQTT `pv` row and the status page carry the corrected figure. Default []
is byte-identical to 0.12.0.

Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0):
a parallel list validates the 0.12.0 blob unchanged and renders as its own
translated repeatable field; dicts on pv_entities refuse 0.12.0's stored
strings; a prefix is invisible syntax; a global bool cannot describe a mixed
roster. Status page marks flipped entities and cautions per entity below
-50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged.

Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 00:25:24 +02:00
21 changed files with 660 additions and 93 deletions
+2
View File
@@ -0,0 +1,2 @@
# The admin/goodwe commit CI tests against. Bump: set to the full SHA of admin/goodwe release/1.0 HEAD (README.md, "CI and the infra pin").
a1d0618eb339b1d4841cd31d6399b67a22b9dfee
+33 -13
View File
@@ -286,8 +286,9 @@ jobs:
run: |
set -eu
rm -rf "$WS" && mkdir -p "$WS/goodwe-addon" && cd "$WS/goodwe-addon"
git init -q .
git remote add origin "$(echo "$URL" | sed "s#://#://x-access-token:${TOKEN}@#")"
git init -q . && git remote add origin "$URL"
# Token as an env-set header: not in argv or .git/config (TOOL-9).
export GIT_CONFIG_COUNT=1 GIT_CONFIG_KEY_0=http.extraHeader GIT_CONFIG_VALUE_0="Authorization: token $TOKEN"
if [ -n "$PRNUM" ]; then
# Two fetches, not one, so that a failure to reach either ref fails
# HERE with the ref in the message, rather than inside the merge
@@ -488,6 +489,31 @@ jobs:
fi
echo "OK: the \`on:\` block of the merged checks.yml carries no event filter."
# CI-12: the infra repo at the ONE pinned commit in .gitea/infra-pin (read
# from the merged tree), as the sibling test_freeze.py looks for. Any
# failure here fails the job; the tests step below refuses the stub.
- name: check out admin/goodwe at the pin in .gitea/infra-pin
env:
URL: ${{ github.server_url }}/admin/goodwe.git
# Read access to admin/goodwe only; this job's own token cannot see it.
TOKEN: ${{ secrets.INFRA_READ_TOKEN }}
run: |
set -eu
# `|| true`: under pipefail a missing or comment-only pin would skip the FAIL line (TOOL-9).
PIN=$(grep -v '^#' "$WS/goodwe-addon/.gitea/infra-pin" | tr -d '[:space:]') || true
echo "$PIN" | grep -Eq '^[0-9a-f]{40}$' || { echo "FAIL: .gitea/infra-pin holds '$PIN', not a full 40-hex SHA."; exit 1; }
test -n "$TOKEN" || { echo "FAIL: secret INFRA_READ_TOKEN is not available to this run (a fork PR?)."; exit 1; }
rm -rf "$WS/goodwe" && mkdir -p "$WS/goodwe" && cd "$WS/goodwe"
git init -q .
# The token goes in a header via env: not in argv, and not in .git/config,
# which is mounted into the tests' container and outlives a failed job.
GIT_CONFIG_COUNT=1 GIT_CONFIG_KEY_0=http.extraHeader GIT_CONFIG_VALUE_0="Authorization: token $TOKEN" \
git fetch -q "$URL" "$PIN" || { echo "FAIL: could not fetch admin/goodwe at $PIN."; exit 1; }
git -c advice.detachedHead=false checkout -qf FETCH_HEAD
test "$(git rev-parse HEAD)" = "$PIN"
test -f sim/hwsim.py || { echo "FAIL: admin/goodwe@$PIN has no sim/hwsim.py."; exit 1; }
echo "infra: admin/goodwe @ $(git log --oneline -1)"
- name: build the test image (shipped deps, from apk - see .gitea/ci/Dockerfile)
run: |
set -eu
@@ -508,16 +534,9 @@ jobs:
# shorter timeout - a 60 s limit was tried during CI-01 and reported
# exactly the false hang the docstring predicts.
#
# ⚠️ WHAT THIS RUN DOES NOT COVER, stated because a pass here would
# otherwise over-claim. test_freeze.py's third section wants the infra
# repo's `sim/hwsim.py` to drive a real HTTP meter through the real
# transport. admin/goodwe is PRIVATE (checked via the API) and this
# workflow's GITHUB_TOKEN is minted for THIS repository only, so hwsim is
# absent here and `find_hwsim()` returns None. The rest of the file runs
# and passes. It does so SILENTLY - the file prints nothing to say the
# hwsim section was skipped - so "test_freeze.py: PASS" below is a weaker
# claim than it looks. That belongs to whoever owns test_freeze.py next;
# naming it here is the least this gate can do about it.
# test_freeze.py part 3 runs against the real `sim/hwsim.py` from the
# checkout above; GOODWE_REQUIRE_HWSIM=1 makes it fail rather than use its
# stub (CI-12). Lines a test prints with a `CI: ` prefix are echoed on PASS.
# ⚠️ PYTHONDONTWRITEBYTECODE=1 IS BELT AND BRACES, NOT A FIX FOR A LIVE
# HOLE. TEST-15 measured this runner's actual exposure and found none: the
# checkout below is bind mounted `:ro`, so the interpreter physically
@@ -533,7 +552,7 @@ jobs:
- name: the add-on's own tests
run: |
set -eu
docker run --rm -e PYTHONDONTWRITEBYTECODE=1 -v "$WS:/w:ro" goodwe-addon-checks:1 sh -eu -c '
docker run --rm -e PYTHONDONTWRITEBYTECODE=1 -e GOODWE_REQUIRE_HWSIM=1 -v "$WS:/w:ro" goodwe-addon-checks:1 sh -eu -c '
cd /w/goodwe-addon/goodwe_controller
set -- test_*.py
if [ "$1" = "test_*.py" ]; then
@@ -546,6 +565,7 @@ jobs:
start=$(date +%s)
if python3 "$f" > /tmp/out 2>&1; then
echo "PASS $f ($(( $(date +%s) - start ))s)"
grep "^CI: " /tmp/out || true
else
echo "FAIL $f ($(( $(date +%s) - start ))s)"
tail -40 /tmp/out
+46
View File
@@ -0,0 +1,46 @@
# CI-12: goes red when admin/goodwe release/1.0 has moved past .gitea/infra-pin.
# It runs on add-on activity only; admin/goodwe's own `addon-pin` workflow
# covers a move of release/1.0 there. Deliberately NOT a required check: it
# reports; `checks / unit` stays the only gate. How to bump: README.md,
# "CI and the infra pin".
name: infra-pin
on:
pull_request:
push:
branches: [release/1.0]
jobs:
fresh:
runs-on: [self-hosted, goodwe-rig]
timeout-minutes: 30 # seconds of work; the rest is queueing for the shared slot
steps:
- name: compare .gitea/infra-pin with admin/goodwe release/1.0
env:
SELF: ${{ github.server_url }}/${{ github.repository }}.git
INFRA: ${{ github.server_url }}/admin/goodwe.git
TOKEN: ${{ secrets.GITHUB_TOKEN }}
INFRA_TOKEN: ${{ secrets.INFRA_READ_TOKEN }} # admin/goodwe is private
run: |
set -eu
D=$(mktemp -d) && trap 'cd / && rm -rf "$D"' EXIT && cd "$D"
git init -q .
# The pin of the commit this event is about (the PR head, or the push).
# Token as an env-set header: not in argv or .git/config (TOOL-9).
GIT_CONFIG_COUNT=1 GIT_CONFIG_KEY_0=http.extraHeader GIT_CONFIG_VALUE_0="Authorization: token $TOKEN" \
git fetch -q --depth 1 "$SELF" "$GITHUB_SHA" || { echo "FAIL: could not fetch $GITHUB_SHA here."; exit 1; }
# `|| true`: under the runner's pipefail a missing or comment-only pin
# would stop here on git's error instead of the FAIL line below (TOOL-9).
PIN=$(git show FETCH_HEAD:.gitea/infra-pin | grep -v '^#' | tr -d '[:space:]') || true
test -n "$PIN" || { echo "FAIL: .gitea/infra-pin is missing at $GITHUB_SHA, or holds only comments."; exit 1; }
test -n "$INFRA_TOKEN" || { echo "FAIL: secret INFRA_READ_TOKEN is not available to this run (a fork PR?)."; exit 1; }
# Header via env, as in checks.yml: the token stays out of argv.
HEAD=$(GIT_CONFIG_COUNT=1 GIT_CONFIG_KEY_0=http.extraHeader GIT_CONFIG_VALUE_0="Authorization: token $INFRA_TOKEN" \
git ls-remote "$INFRA" refs/heads/release/1.0 | cut -f1) || true
test -n "$HEAD" || { echo "FAIL: could not read admin/goodwe release/1.0."; exit 1; }
if [ "$PIN" != "$HEAD" ]; then
echo "STALE: .gitea/infra-pin is $PIN but admin/goodwe release/1.0 is $HEAD."
echo " Test against $HEAD and bump the pin (README.md, \"CI and the infra pin\")."
exit 1
fi
echo "OK: .gitea/infra-pin $PIN is admin/goodwe release/1.0 HEAD."
+6
View File
@@ -105,6 +105,12 @@ has the mechanism, the measurement, and what the flags do not do. They are not u
each assertion corresponds to a rule whose absence produced an observed failure
on real hardware, and the comments in `control.py` say which.
### CI and the infra pin
CI (`.gitea/workflows/checks.yml`) runs every `test_*.py`, with `admin/goodwe` checked out next to this repo at the commit in `.gitea/infra-pin`, so `test_freeze.py` grades against the real `sim/hwsim.py`. If that checkout fails, the job fails. The local stub is used only in local runs, and it prints `STUB USED` when it is.
The pin tracks `admin/goodwe` **release/1.0**, not master. Two non-required checks go red when release/1.0 has moved past the pin: `infra-pin / fresh` here, on any add-on PR or push to release/1.0, and `addon-pin / fresh` in `admin/goodwe`, on every push to its release/1.0. Nothing re-runs `addon-pin` after a bump, so it stays red on that admin/goodwe commit; `infra-pin / fresh` green on the bump is the all-clear.
**Bump the pin** whenever either is red. Set `.gitea/infra-pin` to the new release/1.0 SHA (`git ls-remote <gitea>/admin/goodwe.git refs/heads/release/1.0`) in a PR, and let `checks / unit` grade the tests against it. CI reads `admin/goodwe` with the Actions secret `INFRA_READ_TOKEN`.
## Compatibility
**Check the serial number, not the model name.** Characters 6-8 of the serial are
@@ -38,6 +38,8 @@ the trade [[product-not-one-house]] names.
## 2. The sign convention: **positive is production**, and there is no `pv_invert`
> Reversed by TEL-14 (flag and negative caution): `DECISIONS/TEL-14-pv-sign.md`.
### The convention is derived, not assumed
Two sign rules already ship, and both are recorded in `DOCS.md`'s *Sources*
@@ -0,0 +1,83 @@
# TEL-14 — the PV sign, declared per entity
Owner report on 0.12.0: `sensor.espressif_vermogen` (ESPHome clamp) and
`sensor.kwh_meter_actueel_vermogen` (kWh meter in the PV circuit) read
**positive for consumption, negative for production**. At night the page said
"✓ PV production: 13 W" — standby draw. By day production would publish negative.
## 1. This reverses TEL-11 §2, and why
TEL-11 §2 refused a `pv_invert` on two grounds. "PV is read by nothing in the
control path" still holds: the flip lives in `pv.total()`, and `test_pv.py`
part 12 re-runs part 6's 40-cycle identity with a flip set. "A reversed sensor
announces itself" did not survive a real site: these sensors follow a different
convention, read a plausible small positive number at night, and the only other
fix is a template sensor, the place TEL-12 §2 says goes quietly wrong.
## 2. The shape: a parallel list, `pv_invert_entities`
Measured by `tools/supervisor_shape_probe.py` §H (Supervisor 2026.08.0, against
a 0.12.0 blob); re-run it for the transcript.
| shape | schema | why it lost / won |
|---|---|---|
| (a) `-sensor.x` prefix | accepted | invisible: the sign is a syntax only the description explains, in a field an installer fills with the entity picker's text |
| (b) parallel list | accepted, 0.12.0 blob unchanged | **ships**: its own labelled, translated field ("PV entities whose sign is reversed"); an installer lists the odd ones out |
| (c) dicts on `pv_entities` | **refuses 0.12.0's stored strings** | bricks the upgrade — TEL-12's trap again |
| (c2) dicts as a third key | accepted | per-entry labels render raw (`entity`, `invert`) — probe §F; and a third PV surface |
| (d) global bool | accepted | one sign cannot describe inverter + meter in one roster |
(b)'s known cost is a typo in the second list: `pv.stray_inverts()` turns it into
a named caution. `[]` in `options:` is load-bearing (§H, isolated counterfactual).
Default `[]` flips nothing, so every 0.12.0 install is byte-identical (part 12).
## 3. The negative caution: per entity, below −50 W
The owner's two meters draw ~13 W at night, so a *correctly* signed meter reads
about −13 W then. −50 W clears that with room for a few such devices behind one
entity; a reversed sensor by day reads hundreds to thousands of watts below
zero. It is tested **per entity, not on the total** (a deviation from the brief):
three correct meters at −20 W sum to −60 W and must stay quiet, while a reversed
−1500 W hidden inside a positive total must not. It is a caution, never `bad`;
a wrong threshold costs a spurious or missed caution, never data. The text says
ADD (unflipped) or REMOVE (already flipped).
## 4. Mutations
Fresh `cp -a` each, `__pycache__` purged, CI image, `:ro`, `--network none`;
`test_pv.py` only unless stated. T1-T12 at 7559d21; M2/M5 are review #1628's,
red since B1 (merged into release/1.0 @ 43b2740).
| # | mutation | bytes | reds |
|---|---|---|---|
| T1 | flip ignored in `total()` | −45 | 9 |
| T2 | flip applied to every member | −7 | 6 |
| T3 | `0.0 - w` → `-w` | −5 | 1 |
| T4 | flip written as `abs()` | −1 | 2 |
| T5 | `_read_pv()` stops passing the flip | −26 | 7 |
| T6 | caution threshold −50 → 0 W | −17 | 3 |
| T7 | `[sign inverted]` marker dropped | −39 | 3 |
| T8 | negative caution made `bad` | +1 | 1 |
| T9 | `stray_inverts()` always empty | −50 | 1 |
| T10 | `inverted()` stops stripping | −8 | 1 |
| T11 | ADD/REMOVE advice swapped | +4 | 2 |
| T12 | `pv_invert_entities: []` deleted from `options:` | −25 | 2 test_translations + 17 probe |
| M2 | `stray_inverts()` roster ignores `pv_entity` | +15 | 2 (REPORTED CASE, PADDING) |
| M5 | `_read_pv()` flip set not stripped | +25 | 1 (PADDING) |
## 5. History
OPT-10's `sensor.goodwe_pv_power` recorded since 2026-09-24 on an install with
such sensors carries the old sign; nothing rewrites it.
## 6. CHANGELOG entry for the next PKG cut
Not written into `CHANGELOG.md`: `test_version_gate.py` 11b/11d refuse an
`## Unreleased` heading (measured on this branch: 4 reds). For PKG to paste:
> **`pv_invert_entities` (TEL-14).** A PV sensor that reads negative while
> producing — typically a kWh meter or power clamp in the PV circuit — can now
> be listed under *PV entities whose sign is reversed* in the Configuration tab;
> its sign is flipped before the sum and the status page marks it. Empty (the
> default) changes nothing. ⚠️ PV history recorded before you set it keeps the
> old sign.
+9 -14
View File
@@ -146,6 +146,7 @@ either direction, and the check is mutation-tested both ways.
| `setpoint_entity` | yes | The ESPHome `number.*_goodwe_setpoint_w` |
| `pv_entity` | | Optional. **One** solar inverter's power sensor, `+` = producing. Measurement only — it changes no control behaviour. See [PV production](#pv-production-pv_entity-tel-11) |
| `pv_entities` | | Optional. **Several** solar inverters, one row each — use this instead of `pv_entity` when your roof has more than one. Setting it **ignores** `pv_entity`. See [Several PV inverters](#several-pv-inverters-pv_entities-tel-12) |
| `pv_invert_entities` | | Optional. The PV entities above that read **negative** while producing; each one's sign is flipped. See [The sign](#the-sign-and-pv_invert_entities-tel-14) |
Use the ESP32's readings rather than the inverter's cloud or dongle sensors:
those serve cached values, and a stale reading here ends the maintenance charge
@@ -461,21 +462,15 @@ Only the third is a software defect, and **none of them can be told apart
without a record of production.** This entity is that record. The attribution
itself is OPT-10's, with a week of history behind it.
#### The sign, and why there is no `pv_invert`
#### The sign, and `pv_invert_entities` (TEL-14)
**Positive must mean producing.** That is the same convention as the two sign
rules the add-on already ships — `meter_entity` is positive when **importing**
and `batt_entity` is positive when **discharging**, both of which are "power
arriving at the house" — and production arrives there too.
`meter_invert` and `batt_invert` exist because those two quantities are
**bipolar and are read by the control path**: a reversed battery sensor is a
perfectly plausible number that the per-inverter sign failsafe then acts on.
Production is unipolar and is read by **nothing**, so a reversed sensor here
cannot mislead a decision — and it announces itself immediately as −4 kW at
noon in the very history this entity creates. A flag would only hide it, so
there is not one. If your sensor really is inverted, fix it where it is
produced.
**Positive must mean producing.** Some sensors — typically a kWh meter or an
ESPHome power clamp in the PV circuit — read negative while producing and a few
watts positive at night: list each of those in `pv_invert_entities`, spelled as
in `pv_entity`/`pv_entities`, and its sign is flipped before the sum; the status
page marks it `[sign inverted]` and cautions on any entity reading below −50 W.
History recorded before you set it keeps the old sign. See
`DECISIONS/TEL-14-pv-sign.md`.
#### The unit is read off the entity
+59 -10
View File
@@ -113,6 +113,12 @@ __all__ = ["UNIT_A", "Controller", "amain", "main"]
# the re-issue happens by itself) than hold the control loop for ten seconds.
WRITE_BUDGET_S = 4.0
# SAFETY-34: a Core-only restart wipes persistent_notification and does NOT
# restart this add-on (measured on TEST-23), so a latched alarm is re-asserted
# this often. Why: goodwe docs/DECISIONS.md, SAFETY-34.
REANNOUNCE_S = 300.0
_mono = time.monotonic # patched by the checks; asyncio keeps the real one
# --------------------------------------------------------------------------- #
# OPT-04: THE BACKGROUND TARIFF REFRESH, AND WHY IT IS NOT OPTIONAL
#
@@ -691,6 +697,9 @@ class Controller:
# does, so the latch alone is not the alarm - re-raising it is.
# `run_control()` does that, once, before the first cycle.
self._circ_announced = False
# SAFETY-34: when each latched alarm was last put in front of HA, by
# notification_id - see REANNOUNCE_S.
self._announced_mono = {}
if self.circ_wd.tripped:
_LOG.error(
"SAFETY-31 was TRIPPED before this restart and stays tripped: "
@@ -1726,7 +1735,7 @@ class Controller:
states = await asyncio.gather(
*(self.hass.state(entity) for entity in roster))
self.pv_w, self.pv_why, self.pv_parts = pv_read.total(
list(zip(roster, states)))
list(zip(roster, states)), pv_read.inverted(self.o))
async def read_inputs(self, now_mono: float | None = None) -> None:
"""Every input this cycle needs, and SAFETY-37's freshness verdict.
@@ -3943,15 +3952,17 @@ class Controller:
The latch says "this site is tripped"; the flag says "this process has
put that in front of a human". A restart clears the flag and keeps the
latch, so the notification is RE-RAISED on the first cycle after every
add-on start - which is also the first cycle after a Home Assistant
restart, because the add-on is restarted with it.
add-on start. A Core-only restart does NOT restart the add-on, so it is
also re-asserted every REANNOUNCE_S (SAFETY-34).
⚠️ ONE CODE PATH FOR BOTH, ON PURPOSE. A fresh trip and a restart into
an existing trip raise the alarm through these same lines. Two paths
would be two chances for the restart one to rot unnoticed, and the
restart one is the case nobody exercises by hand.
"""
if not self.circ_wd.tripped or self._circ_announced:
if not self.circ_wd.tripped:
return
if self._circ_announced and not self._reannounce_due("goodwe_circulating_power"):
return
# Set BEFORE the await. `hass.call()` can raise or hang, and a retry
# every cycle for a broker that is down would be an alarm storm on the
@@ -3959,6 +3970,7 @@ class Controller:
# already durable and the log line above already fired; this surface is
# best-effort by design.
self._circ_announced = True
self._announced_mono["goodwe_circulating_power"] = _mono()
names = self.units
pos, neg = opposing([inv.batt for inv in self.inverters],
min_w=self.circ_wd.cfg.min_w / 2.0)
@@ -3993,6 +4005,11 @@ class Controller:
f"know why two inverters were opposing."),
})
def _reannounce_due(self, notification_id: str) -> bool:
"""SAFETY-34: has this latched alarm gone REANNOUNCE_S without being re-asserted?"""
t = self._announced_mono.get(notification_id)
return t is None or _mono() - t >= REANNOUNCE_S
async def check_not_delivering(self) -> None:
"""SAFETY-42 + SAFETY-34. The alarm, and it must survive a restart.
@@ -4012,8 +4029,8 @@ class Controller:
not persisted. The latch says "this unit is tripped"; membership says
"this process has put that in front of a human". A restart empties the
set and keeps the latch, so the notification is RE-RAISED on the first
cycle after every add-on start - which is also the first cycle after a
Home Assistant restart, because the add-on is restarted with it.
cycle after every add-on start, and re-asserted every REANNOUNCE_S
because a Core-only restart does not restart the add-on (SAFETY-34).
⚠️ ONE CODE PATH FOR BOTH, ON PURPOSE - `check_circulating()`'s
argument. A fresh trip and a restart into an existing trip raise the
@@ -4031,7 +4048,10 @@ class Controller:
names = self.units
slugs = unit_slugs(names)
for inv, slug in zip(self.inverters, slugs):
if not inv.delivery_wd.tripped or inv.name in self._delivery_announced:
nid = f"goodwe_not_delivering_{slug}"
if not inv.delivery_wd.tripped:
continue
if inv.name in self._delivery_announced and not self._reannounce_due(nid):
continue
# Added BEFORE the await, for `check_circulating()`'s reason:
# `hass.call()` can raise or hang, and a retry every cycle for a
@@ -4039,9 +4059,10 @@ class Controller:
# latch is already durable and the log line already fired; this
# surface is best-effort by design.
self._delivery_announced.add(inv.name)
self._announced_mono[nid] = _mono()
peers = ", ".join(n for n in names if n != inv.name) or "no sibling"
await self.hass.call("persistent_notification", "create", {
"notification_id": f"goodwe_not_delivering_{slug}",
"notification_id": nid,
"title": f"GoodWe: {inv.name} is not delivering its share",
"message": (
f"{inv.delivery_wd.reason}\n\nWHY NOTHING ELSE SAID SO. A "
@@ -5075,6 +5096,13 @@ class Controller:
# have to say something the single-entity ones never could.
roster = self.pv_roster
if roster:
# TEL-14: each flipped entity is marked where its watts are printed;
# an unflipped one gets "", so 0.12.0's sentences are unchanged.
flip = pv_read.inverted(self.o)
def inv(ent):
return " [sign inverted]" if ent in flip else ""
if len(roster) == 1:
if self.pv_w is None:
out.append({"ok": False, "warn": True,
@@ -5089,7 +5117,7 @@ class Controller:
out.append({"ok": True, "warn": False,
"text": f"PV production: {self.pv_w:.0f} W "
f"from {roster[0]} (reported "
f"in {self.pv_why})"})
f"in {self.pv_why})" + inv(roster[0])})
elif self.pv_w is None:
# ⚠️ THE ROW THAT SAYS THERE IS NO TOTAL, AND IT SAYS IT IN
# THOSE WORDS. `pv.total()`'s note is the argument; this is
@@ -5104,7 +5132,7 @@ class Controller:
"text": "PV production: NO SITE TOTAL - "
+ self.pv_why + ". Reporting: "
+ (", ".join(
f"{ent} {watt:.0f} W"
f"{ent} {watt:.0f} W" + inv(ent)
for ent, watt, _y in self.pv_parts
if watt is not None) or "nothing")})
else:
@@ -5117,6 +5145,7 @@ class Controller:
f"{len(self.pv_parts)} entities ("
+ ", ".join(
f"{ent} {watt:.0f} W in {why}"
+ inv(ent)
for ent, watt, why in self.pv_parts)
+ ")"})
# ⚠️ AND WHEN BOTH KEYS ARE SET, WHICH ONE WON IS STATED. `pv.py`'s
@@ -5136,6 +5165,26 @@ class Controller:
f"{len(roster)} entities in the "
"list are what is summed. Clear "
"`pv_entity` to remove this caution"})
# TEL-14: a sign that looks reversed, per entity rather than on the
# total - see `pv.NEGATIVE_W` and DECISIONS/TEL-14-pv-sign.md §3.
for ent, watt, _y in self.pv_parts:
if watt is not None and watt < pv_read.NEGATIVE_W:
out.append({"ok": False, "warn": True,
"text": f"PV production: {ent} reads "
f"{watt:.0f} W - far below zero, so "
f"its sign is probably reversed. If "
f"it is producing now, "
+ ("REMOVE it from "
"`pv_invert_entities`"
if ent in flip else
"ADD it to `pv_invert_entities`")
+ " in the Configuration tab"})
for ent in pv_read.stray_inverts(self.o):
out.append({"ok": False, "warn": True,
"text": f"PV production: `pv_invert_entities` "
f"names {ent}, which is not a PV entity in "
f"use, so it flips nothing - check the "
f"spelling against `pv_entities`"})
return out
def status_payload(self) -> dict:
+32 -17
View File
@@ -50,21 +50,10 @@ SITE figure, and it publishes as an absence. A partial sum is a second way of
reporting 0-where-there-was-production, one layer up, and it is refused for the
same reason.
THE SIGN CONVENTION: POSITIVE IS PRODUCTION. Derived from the two conventions
this add-on already ships rather than assumed:
`meter_entity` positive = IMPORTING from the grid (DOCS.md, Sources)
`batt_entity` positive = DISCHARGING the pack (DOCS.md, Sources)
Both are "positive = power arriving at the house's AC bus", and production
arrives there too. There is deliberately NO `pv_invert` to go with
`meter_invert` and `batt_invert`: those two quantities are BIPOLAR and are READ
BY THE CONTROL PATH - a reversed `batt_entity` feeds SAFETY-30's per-unit sign
check and SAFETY-31's circulating-power sensor with a plausible number the site
then acts on - whereas production is unipolar and is read by nothing. A reversed
PV sensor announces itself as -4 kW at noon in the very history this card
creates, and flipping it here would only hide it. See
`DECISIONS/TEL-11-pv-production.md` §2.
THE SIGN CONVENTION: POSITIVE IS PRODUCTION, as for `meter_entity` and
`batt_entity` ("power arriving at the house's AC bus"). TEL-14: a kWh meter or
power clamp in the PV circuit reads the other way, so `pv_invert_entities`
flips the sign per entity. See `DECISIONS/TEL-14-pv-sign.md`.
"""
from .hass import BAD_STATES
@@ -193,7 +182,28 @@ def entity_is_ignored(opts: dict) -> bool:
if str(x or "").strip()])
def total(readings) -> tuple:
def inverted(opts: dict) -> frozenset:
"""The entity ids `pv_invert_entities` flips. TEL-14."""
return frozenset(e for e in (str(x or "").strip()
for x in (opts.get("pv_invert_entities") or []))
if e)
def stray_inverts(opts: dict) -> list:
"""`pv_invert_entities` entries naming no entity in the roster - a typo
that would otherwise leave a sign unflipped with nothing said. TEL-14."""
roster = set(entities(opts))
return sorted(e for e in inverted(opts) if e not in roster)
# TEL-14: a reading below this is not standby draw. A correctly signed meter in
# the PV circuit reads a few watts NEGATIVE at night (the owner's: 13 W); -50 W
# clears that with room for a couple of such devices on one entity, while a
# reversed sensor in daylight reads hundreds to thousands of watts below zero.
NEGATIVE_W = -50.0
def total(readings, flip=frozenset()) -> tuple:
"""`(watts, why, parts)` - the SITE's production, or an ABSENCE. TEL-12.
`readings` is `[(entity_id, state), ...]` in `entities()` order, one entry
@@ -237,8 +247,13 @@ def total(readings) -> tuple:
site: shading, a tripped string and nightfall are all real 0s, and a roster
that went to `unknown` whenever one member read zero would report an absence
on every clear evening and defeat the channel from the other end.
⚠️ TEL-14: `flip` is `inverted(opts)`; each member's sign is applied HERE,
before the sum, so every surface reads the corrected figure. `0.0 - w`
rather than `-w`, so a flipped 0 W is `0.0` and never `-0.0` on the wire.
"""
parts = [(ent, *watts(st)) for ent, st in readings]
parts = [(ent, w if w is None or ent not in flip else 0.0 - w, why)
for ent, (w, why) in ((e, watts(st)) for e, st in readings)]
if not parts:
# No roster. `Controller` does not call this in that state - the gate is
# `pv_roster` - but a reader of `parts` should never have to wonder.
+12 -6
View File
@@ -159,12 +159,8 @@ options:
# So this takes whatever `sensor.*` the site's PV integration provides, any
# brand Home Assistant can read.
#
# ⚠️ POSITIVE IS PRODUCTION, and there is deliberately no `pv_invert` beside
# `meter_invert` and `batt_invert`. Those two quantities are bipolar AND are
# read by the control path, so a reversed sensor there is a plausible number
# the site acts on; production is unipolar and is read by nothing, so a
# reversed sensor announces itself as -4 kW at noon in the history this key
# exists to create. See DECISIONS/TEL-11-pv-production.md.
# POSITIVE IS PRODUCTION. An entity that reads the other way round goes in
# `pv_invert_entities` below - see DECISIONS/TEL-14-pv-sign.md.
#
# ⚠️ THE ENTITY'S OWN `unit_of_measurement` IS WHAT IS BELIEVED - W, kW, MW
# and the rest of Home Assistant's power units. A sensor with no unit, or with
@@ -215,6 +211,12 @@ options:
# which is also empty" - i.e. no PV channel at all, which is every install.
pv_entities: []
# TEL-14. Every PV entity listed here (in `pv_entity` or `pv_entities`) has
# its sign flipped, for a kWh meter or power clamp that reads production as
# negative. Per entity, because one roster can mix both conventions. `[]` is
# load-bearing like `pv_entities: []`; see DECISIONS/TEL-14-pv-sign.md.
pv_invert_entities: []
# ==========================================================================
# METER - where the grid reading comes from
# ==========================================================================
@@ -972,6 +974,10 @@ schema:
# `p1_phase_import_entities` is the shipped precedent for the pair.
pv_entities:
- str
# TEL-14. A parallel list, not a prefix or a dict: measured by
# tools/supervisor_shape_probe.py section H, DECISIONS/TEL-14-pv-sign.md.
pv_invert_entities:
- str
# ==========================================================================
# METER - where the grid reading comes from
+3 -5
View File
@@ -10,12 +10,10 @@ IN FULL.
⚠️ WHAT THIS FILE CAN AND CANNOT CLAIM, SAID BEFORE THE FIRST CHECK.
The two-master rig lives in admin/goodwe (TEST-19, `sim/sitesim.py`), where
`compute()` closes the loop against `plantsim.Plant` with the firmware's own
encoder on the wire. That repository is PRIVATE and this repository's CI token
is minted for this one, so the rig is not reachable from the gate - and a test
file that needed it would either fail the gate or, like test_freeze.py's hwsim
section, pass SILENTLY having checked nothing.
encoder on the wire. CI checks admin/goodwe out at `.gitea/infra-pin` (CI-12),
but this file does not import the rig.
So the split is deliberate:
The split:
* `tools/alloc_sim.py` drives the REAL rig, and its output is quoted in the
pull request. It is where "no limit cycle" is a claim about the shipped
+3 -4
View File
@@ -62,10 +62,9 @@ the step it wants: if checks.yml is restructured so that the step cannot be
found, this file goes RED rather than quietly grading nothing.
⚠️ NEEDS `git`, which is why .gitea/ci/Dockerfile installs it. No network: the
fixtures are local repositories built in a temp directory, and the workflow's
`git remote add origin "$(echo "$URL" | sed "s#://#://x-access-token:...@#")"`
is a no-op substitution on a path with no `://` in it, which is what lets the
shipped line be used verbatim.
fixtures are local repositories built in a temp directory; the workflow's
token header (TOOL-9) is ignored for a local path, which is what lets the
shipped lines be used verbatim.
⚠️ This file writes only under a temporary directory. It must stay that way:
CI mounts the checkout READ-ONLY.
+5 -7
View File
@@ -990,13 +990,11 @@ check("⭐ RESTORING slew_w 1000 AT max_w 5000 IS FASTER THAN THE PLANT, and by
#
# ⚠️ THE PLANT BELOW IS MODELLED HERE AND IS NOT THE RIG. admin/goodwe's
# `plantsim.Plant` is the battery model this project grades control changes
# against, and this repository's CI cannot reach it - that repository is private
# and this job's token is minted for this one (see .gitea/workflows/checks.yml).
# So the rig evidence lives in `tools/slew_sim.py`, is quoted in the pull
# request and in DECISIONS/SAFETY-39-slew-against-the-rail.md, and what runs
# HERE is a first-order lag with the time constant that reproduces §5.10's
# measured ~18 s to the deadband. test_alloc.py makes the same split for the
# same reason and says so in the same words.
# against. CI checks admin/goodwe out at `.gitea/infra-pin` (CI-12), but this
# file does not import `plantsim`. The rig evidence lives in `tools/slew_sim.py`,
# is quoted in the pull request and in DECISIONS/SAFETY-39-slew-against-the-rail.md,
# and what runs HERE is a first-order lag with the time constant that reproduces
# §5.10's measured ~18 s to the deadband. test_alloc.py makes the same split.
#
# ⚠️ AND IT CANNOT SHOW A BATTERY ABOVE ITS RATING, WHICH IS SAID BEFORE THE
# RESULT RATHER THAN AFTER IT. Neither this model nor `plantsim.Plant` lets the
+36 -2
View File
@@ -1195,8 +1195,8 @@ async def _restart():
c1 = _ctrl(h1, store=shared)
await _drive(c1)
# A NEW process, a NEW HomeAssistant object (so the in-memory notification
# is gone with it), the SAME durable file. That is what a Home Assistant
# restart is from this add-on's point of view: the add-on goes with it.
# is gone with it), the SAME durable file: an ADD-ON restart. A Core-only
# restart keeps the process; graded in part 8b (SAFETY-34).
h2 = _DeliveryHass(b_soc=50.0)
c2 = _ctrl(h2, store=shared)
await c2.check_not_delivering()
@@ -1250,6 +1250,40 @@ check("the operator's START press is the only way out, and it clears the "
and _rs.data.get(unit_key("inverter-b", "delivery_reason")) == ""
and _r2._delivery_announced == set())
print()
print("8b. SAFETY-34: a Core-only restart - same add-on process, HA's memory wiped")
import app.main as _main_mod # noqa: E402
async def _core_restart():
shared = _MemStore()
c = _ctrl(_DeliveryHass(b_soc=50.0), store=shared)
await _drive(c)
return c
_c = asyncio.run(_core_restart())
_real_mono, _clock = _main_mod._mono, [_main_mod._mono()]
_main_mod._mono = lambda: _clock[0]
try:
_c.hass = _DeliveryHass(b_soc=50.0)
asyncio.run(_c.check_not_delivering())
_early = [x for x in _c.hass.calls
if "not_delivering" in str(x[2].get("notification_id", ""))]
_clock[0] += _main_mod.REANNOUNCE_S
asyncio.run(_c.check_not_delivering())
_late = [x for x in _c.hass.calls
if "not_delivering" in str(x[2].get("notification_id", ""))]
finally:
_main_mod._mono = _real_mono
check("SAFETY-34: the latch tripped in this process",
_c.inverters[1].delivery_wd.tripped)
check("SAFETY-34: inside REANNOUNCE_S the same process does not re-raise",
len(_early) == 0)
check("SAFETY-34: after REANNOUNCE_S the SAME process re-asserts the card, "
"because a Core-only restart wiped it and did not restart the add-on",
len(_late) == 1 and "inverter_b" in _late[0][2]["notification_id"])
print()
if fails:
+13 -2
View File
@@ -19,7 +19,8 @@ shipped `meter_freeze_s` itself:
a check that calls the predicate directly would not be testing the thing
that ships. Uses the rig's own `sim/hwsim.py --fault freeze` when the infra
repo is next to this one (or `$GOODWE_SIM`), and an equivalent local stub
otherwise. Both are exercised; the run says which one it used.
otherwise. Both are exercised; the run says which one it used. CI sets
`GOODWE_REQUIRE_HWSIM=1`, which refuses the stub (CI-12).
4. THE WIRING: the real `Controller.cycle()`, asserted on the service call
that leaves the process;
@@ -600,6 +601,15 @@ hw = find_hwsim()
# that cannot fail, from the other end.
PART3_TRANSPORT = f"the rig hwsim at {hw}" if hw else "the local stub"
print(f"frozen meter over HTTP - using {PART3_TRANSPORT}")
# CI-12: CI sets GOODWE_REQUIRE_HWSIM=1, so a missing infra checkout fails here
# instead of passing on the stub. Local runs may still use the stub, and say so.
if not hw:
if os.environ.get("GOODWE_REQUIRE_HWSIM"):
print("FAIL: GOODWE_REQUIRE_HWSIM is set but sim/hwsim.py was not found "
"(sibling ../goodwe or $GOODWE_SIM) - refusing to fall back to the stub")
sys.exit(1)
print("STUB USED: part 3 ran against the local stub, NOT the infra repo's "
"sim/hwsim.py - not a CI-grade result")
if hw:
def argv_for(mode):
return [HWSIM_DRIVER, "8791" if mode == "freeze" else "8792", mode,
@@ -1263,7 +1273,8 @@ check("a Controller built with the key absent lands on the SHIPPED hold, so "
_ctl_c.freeze_wd.cfg.hold_s == SHIPPED_HOLD_S)
print()
print(f"part 3 (the live HTTP transport) ran against: {PART3_TRANSPORT}")
# `CI: ` lines are echoed into the CI log even on a pass (checks.yml).
print(f"CI: test_freeze part 3 (the live HTTP transport) ran against: {PART3_TRANSPORT}")
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
sys.exit(1)
+215 -6
View File
@@ -56,7 +56,8 @@ absence every clear evening.
Part 8 ⭐⭐ THE SUM, AND WHAT ONE ABSENT MEMBER DOES TO IT.
Part 9 ⭐ publication at a roster of three, as payload bytes.
Part 10 the operator surfaces at three - and 0.11.0's, unchanged, at one.
Part 11 what this file cannot see, with sizes, and both mutation tables.
Part 11 what this file cannot see, with sizes, and the mutation tables.
Part 12 TEL-14: the sign, declared per entity (runs before part 11).
⚠️ MUTATING A MODULE THIS FILE GRADES? PURGE `__pycache__` FIRST - or run
`tools/mutation_run.sh`, which does. `python3 -B` alone does NOT save you: it
@@ -666,7 +667,9 @@ NEEDLES = ("pv_entity", "pv_w", "pv_why", "optional_keys", "ABSENT_AS_UNKNOWN",
# TEL-12's own names. `pv_entities` and `pv_entity` share a prefix so
# the first would have caught it anyway; spelled out because a scope
# that only works by accident stops working when a name is renamed.
"pv_entities", "pv_parts", "pv_roster", "entity_is_ignored")
"pv_entities", "pv_parts", "pv_roster", "entity_is_ignored",
# TEL-14's.
"pv_invert_entities", "stray_inverts", "NEGATIVE_W")
def touches(src: str) -> bool:
@@ -1020,6 +1023,209 @@ check("...and an install with NO PV roster still adds no row of any kind - the "
and run(cycles=1, pv_entities=[" "])[1].state_calls == [])
# ==============================================================================
print()
print("12. TEL-14: the sign, declared PER ENTITY")
# ==============================================================================
# Some installs' PV entities read POSITIVE for consumption and NEGATIVE for
# production (a kWh meter or an ESPHome clamp in the PV circuit). The fixture is
# a MIXED roster, because that is the case a global flag gets wrong:
# E1 an inverter, positive = producing 1200 W -> 1200
# E2 a meter, NEGATIVE = producing, flipped -2.1 kW -> 2100
# E3 a meter at night, correctly signed, NOT flipped: -30 W standby -> -30
# and the values keep every wrong reduction apart:
# right 3270; no flip -930; flip all 930; abs() of every member 3330;
# flip E3 instead of E2 -870.
# ⚠️ EVERY CHECK BELOW READS THROUGH `_at`/`_row` AND NEVER INDEXES BLIND, so a
# missing value is a NAMED FAIL rather than a traceback that hides the rest.
def _at(seq, i):
"""`seq[i]`, or None when there is no such element."""
try:
return seq[i]
except (IndexError, KeyError, TypeError):
return None
def _row(c, needle):
"""Every status-row dict whose text contains `needle` (a list, maybe [])."""
try:
return [r for r in c.checks() if needle in r.get("text", "")]
except Exception as e: # noqa: BLE001 - named, below
return [{"text": f"checks() raised {e!r}", "ok": None, "warn": None}]
MIX = {E1: [state("1200", "W")], E2: [state("-2.1", "kW")],
E3: [state("-30", "W")]}
MIX_TOTAL = 3270.0
_MIX_WRONG = {"no flip": -930.0, "flip all": 930.0, "abs": 3330.0,
"flip E3 not E2": -870.0}
PV_FLIP = dict(PV_MANY, pv_invert_entities=[E2])
check(f"PRECONDITION: the mixed fixture's right answer {MIX_TOTAL:g} W is apart "
f"from every wrong reduction {_MIX_WRONG}",
MIX_TOTAL not in _MIX_WRONG.values()
and len(set(_MIX_WRONG.values())) == len(_MIX_WRONG))
# --- the option ---------------------------------------------------------------
check("inverted() is the stripped, non-empty entries of `pv_invert_entities`, "
"and a 0.12.0 blob (no key at all) flips nothing",
pv.inverted({"pv_invert_entities": [" sensor.a ", "", None, "sensor.b"]})
== frozenset({"sensor.a", "sensor.b"})
and pv.inverted({}) == frozenset()
and pv.inverted({"pv_invert_entities": None}) == frozenset())
# --- the arithmetic -----------------------------------------------------------
_t_mix = pv.total([(e, _at(MIX[e], 0)) for e in (E1, E2, E3)],
pv.inverted(PV_FLIP))
_t_raw = pv.total([(e, _at(MIX[e], 0)) for e in (E1, E2, E3)])
print(f" mixed, E2 flipped: {_t_mix[0]} no flip: {_t_raw[0]}")
check(f"⭐ A MIXED ROSTER: only the listed entity is flipped, before the sum - "
f"{MIX_TOTAL:g} W, not any of {_MIX_WRONG}",
_t_mix[0] == MIX_TOTAL
and [w for _e, w, _y in _t_mix[2]] == [1200.0, 2100.0, -30.0])
check("⭐ DEFAULT IS 0.12.0: with no flip `total()` answers exactly what it "
"always did - the raw sum, the same `why`, the same parts",
_t_raw == (-930.0, "3 entities",
[(E1, 1200.0, "W"), (E2, -2100.0, "kW"), (E3, -30.0, "W")]))
_t_zero = pv.total([(E2, state("0", "W"))], frozenset({E2}))
check("a flipped 0 W is +0.0, never -0.0 - so the wire says `0.0` and the page "
"says `0 W`, not `-0`",
_t_zero[0] == 0.0 and str(_t_zero[0]) == "0.0"
and f"{_t_zero[0]:.0f}" == "0")
_t_gone = pv.total([(E1, state("1200")), (E2, None)], frozenset({E2}))
check("a flipped member that is ABSENT is still an absence of the total - the "
"flip never turns None into a number",
_t_gone[0] is None and _at(_at(_t_gone[2], 1), 1) is None)
check("a single flipped entity keeps 0.11.0's pass-through `why` (the unit)",
pv.total([(E2, state("-13", "W"))], frozenset({E2}))
== (13.0, "W", [(E2, 13.0, "W")]))
# --- the read path, the wire and the page -------------------------------------
_c_mix, _, _p_mix = run(cycles=1, by_entity=MIX, **PV_FLIP)
_f_mix = _at(_p_mix.frames, -1) or {}
print(f" controller pv_w {_c_mix.pv_w} wire {pv_msg(_f_mix)}")
check("⭐ END TO END: the controller reads the option, and the MQTT `pv` row "
"carries the corrected site total",
_c_mix.pv_w == MIX_TOTAL
and pv_msg(_f_mix) == ("goodwe_ctl/pv", "3270.0", False))
_mix_row = [r["text"] for r in _row(_c_mix, "W from 3 entities")]
print(f" {_mix_row}")
check("the status row prints each entity's watts AFTER the sign and marks "
"ONLY the flipped one",
_mix_row == [f"PV production: 3270 W from 3 entities ({E1} 1200 W in W, "
f"{E2} 2100 W in kW [sign inverted], {E3} -30 W in W)"])
check("...and the page's PV row is the corrected total",
("PV", "3 270 W") in page_rows(_c_mix))
_c_hole_f, _, _ = run(cycles=1, by_entity=dict(MIX, **{E1: [None]}), **PV_FLIP)
check("a holed roster's 'Reporting:' list marks the flipped entity too",
[r["text"] for r in _row(_c_hole_f, "Reporting:")]
and f"{E2} 2100 W [sign inverted]" in
(_at(_row(_c_hole_f, "Reporting:"), 0) or {}).get("text", ""))
# The owner's report, at a roster of one: a meter reading +13 W at night.
_OWN = "sensor.pv_meter_power"
_c_own, _, _ = run(cycles=1, by_entity={_OWN: [state("13", "W")]},
pv_entity=_OWN, pv_invert_entities=[_OWN])
_c_own0, _, _ = run(cycles=1, by_entity={_OWN: [state("13", "W")]},
pv_entity=_OWN)
check("⭐ THE REPORTED CASE: 13 W of night-time standby on a reversed meter is "
"-13 W once flipped, the row says so and marks it - and it raises NO "
"negative caution, because -13 W is standby and not a reversed sign - "
"and NO stray caution, because a lone `pv_entity` is in the roster",
_c_own.pv_w == -13.0
and [r["text"] for r in _row(_c_own, "PV production: -13 W")]
== [f"PV production: -13 W from {_OWN} (reported in W) [sign inverted]"]
and _row(_c_own, "probably reversed") == []
and _row(_c_own, "flips nothing") == [])
check("...and WITHOUT the option it is 0.12.0's row, byte for byte",
[r["text"] for r in _row(_c_own0, "PV production:")]
== [f"PV production: 13 W from {_OWN} (reported in W)"])
# Whitespace: the roster entry and the invert entry differ only by padding. Both
# sides must normalise the same way, or the read path leaves the sign unflipped
# while the page marks it, or the page calls a flipped entity a stray.
_c_pad, _, _ = run(cycles=1, by_entity=MIX,
pv_entities=[E1, f" {E2}", E3],
pv_invert_entities=[f"{E2} "])
check("⭐ PADDING: ` sensor.x` in the roster and `sensor.x ` in "
"`pv_invert_entities` are the same entity - flipped on the read path, "
"marked on the page, and no stray caution",
_c_pad.pv_w == MIX_TOTAL
and f"{E2} 2100 W in kW [sign inverted]"
in (_at(_row(_c_pad, "W from 3 entities"), 0) or {}).get("text", "")
and _row(_c_pad, "flips nothing") == [])
# --- the negative caution -------------------------------------------------------
def _neg(watts_by_entity, flip=()):
opts = dict(PV_MANY, pv_invert_entities=list(flip))
c, _, _ = run(cycles=1, by_entity={e: [state(str(w), "W")]
for e, w in watts_by_entity.items()},
**opts)
return _row(c, "probably reversed")
_n_add = _neg({E1: 1200, E2: -1500, E3: 450})
_n_rm = _neg({E1: 1200, E2: 1500, E3: 450}, flip=[E2])
print(f" {[r['text'] for r in _n_add + _n_rm]}")
check("⭐ AN UNFLIPPED ENTITY FAR BELOW ZERO gets a caution that names it, its "
"watts, and says to ADD it to `pv_invert_entities`",
[r["text"] for r in _n_add]
== [f"PV production: {E2} reads -1500 W - far below zero, so its sign "
"is probably reversed. If it is producing now, ADD it to "
"`pv_invert_entities` in the Configuration tab"])
check("...and a FLIPPED one far below zero is told to REMOVE it instead",
len(_n_rm) == 1 and "REMOVE it from `pv_invert_entities`"
in (_at(_n_rm, 0) or {}).get("text", ""))
check("⭐ ...and it is a CAUTION, never a `bad` row - a telemetry sign cannot "
"put a battery site into NOT READY",
bool(_n_add) and all(r.get("ok") is False and r.get("warn") is True
for r in _n_add + _n_rm))
check(f"the threshold is {pv.NEGATIVE_W:g} W per ENTITY: -50 W is standby and "
"stays quiet, -51 W cautions",
pv.NEGATIVE_W == -50.0
and _neg({E1: -50, E2: 0, E3: 0}) == []
and len(_neg({E1: -51, E2: 0, E3: 0})) == 1)
check("⭐ ...PER ENTITY, NOT ON THE TOTAL: three correctly signed meters at "
"-20 W standby each (total -60 W) raise nothing, and a reversed -1500 W "
"hidden in a positive total (+1650 W) is still caught",
_neg({E1: -20, E2: -20, E3: -20}) == []
and len(_neg({E1: 2700, E2: -1500, E3: 450})) == 1)
# --- the stray entry ------------------------------------------------------------
_c_typo, _, _ = run(cycles=1, by_entity=FULL,
**dict(PV_MANY, pv_invert_entities=["sensor.pv_wset"]))
check("a `pv_invert_entities` entry naming no PV entity in use is a named "
"caution (a typo would otherwise leave the sign silently unflipped)",
[(r["text"], r.get("ok"), r.get("warn"))
for r in _row(_c_typo, "flips nothing")]
== [("PV production: `pv_invert_entities` names sensor.pv_wset, which "
"is not a PV entity in use, so it flips nothing - check the "
"spelling against `pv_entities`", False, True)]
and _row(_c_mix, "flips nothing") == [])
# --- default: byte-identical to 0.12.0 ------------------------------------------
_c_d0, _, _p_d0 = run(cycles=1, by_entity=MIX, **PV_MANY)
_c_d1, _, _p_d1 = run(cycles=1, by_entity=MIX,
**dict(PV_MANY, pv_invert_entities=[]))
check("⭐ DEFAULT: `pv_invert_entities: []` and a 0.12.0 blob with no such key "
"give the same rows, the same frame and the raw sum",
[r["text"] for r in _c_d0.checks()] == [r["text"] for r in _c_d1.checks()]
and _at(_p_d0.frames, -1) == _at(_p_d1.frames, -1)
and _c_d0.pv_w == -930.0)
# --- still not a control input --------------------------------------------------
_BIG_FLIP = {E1: [state("1500", "W")], E2: [state("-4.5", "kW")],
E3: [state("2000", "W")]}
_c_bf, _h_bf, _ = run(**_stim, by_entity=_BIG_FLIP,
**dict(PV_MANY, pv_invert_entities=[E2]))
check("⭐ NOT A CONTROL INPUT, WITH A FLIP: 40 cycles against the settled 600 W "
"import write exactly what `unset` writes, and the flip really did move "
"the reading (8000 W, part 6's shift precondition)",
_h_bf.writes == _w_none and _c_bf.target == _c_none.target
and _c_bf.pv_w == BIG_TOTAL)
# ==============================================================================
print()
print("11. what this file CANNOT see, with sizes - and the mutation table")
@@ -1032,10 +1238,9 @@ for line in [
" (mqtt/const.py PAYLOAD_NONE, mqtt/sensor.py's `_message_received`,",
" retrieved 2026-09-24) and quoted in app/mqtt.py. No HA runs in this",
" suite, so what is graded here is the BYTES this add-on publishes.",
"Whether the operator's PV sensor is telling the truth. A sensor wired",
" backwards reads -4 kW at noon; this file asserts that the sign is",
" published unchanged, never that it is right. That is what the history",
" the card creates is FOR - see DECISIONS/TEL-11-pv-production.md §2.",
"Whether the operator's PV sensor is telling the truth. TEL-14 lets the",
" installer declare a reversed one; this file grades the flip and the",
" -50 W caution, never that the declaration is right.",
"The control-path claim OUTSIDE app/. `tools/`, the ESPHome firmware and",
" the ingress page are not scanned by part 6's census.",
"A roster of more than one INVERTER (CFG-04's battery kind). Every",
@@ -1142,6 +1347,10 @@ print(" time - see DECISIONS/TEL-11-pv-production.md §5 for the transcript."
print(" ⚠️ A RED COUNT IS A PROPERTY OF THE SUITE AS MUCH AS OF THE MUTATION:")
print(" these name THIS tree. Re-measure rather than inherit.")
print()
print(" TEL-14: 14 mutations, all red, no survivors - bytes and named reds in")
print(" DECISIONS/TEL-14-pv-sign.md §4.")
print()
if fails:
print(f"{len(fails)} FAILED:")
+3 -3
View File
@@ -90,9 +90,9 @@ guard has to improve on, which is the useful thing a 2-day replay can say.
The two days are committed here as `scenarios/p1-net-<date>.jsonl.gz`
(`{"t": iso8601, "w": signed_watts}` per line, derived from the HA recorder
export) for the reason `scenarios/p1-age-2026-08-26.jsonl.gz` already is: the
infra repo is private, CI's token is minted for this repository only, and a
regression fixture that CI cannot see is not a regression fixture.
export), as `scenarios/p1-age-2026-08-26.jsonl.gz` already is. When they were
committed, CI could not see the infra repo; since CI-12 it checks admin/goodwe
out at `.gitea/infra-pin`, but these fixtures stay here with the tests.
The recorder's window rolls: 2026-08-01 leaves it around 2026-09-15, which is
why the committed copy is the artefact and not the API call.
+24 -2
View File
@@ -1055,8 +1055,8 @@ async def _circ_restart():
await a.read_inputs()
await a.cycle()
await asyncio.sleep(0.25)
# THE RESTART. Same store, brand new Controller and Hass - which is exactly
# what a Home Assistant restart does to this add-on. The house has stopped
# THE RESTART. Same store, brand new Controller and Hass - an ADD-ON
# restart. A Core-only restart keeps the process; graded below (SAFETY-34). The house has stopped
# circulating in the meantime, so nothing in the new process's own
# measurements could re-derive the trip.
h2 = _CircHass(a_w=0.0, b_w=0.0)
@@ -1116,6 +1116,28 @@ check("...and it does not raise the same card on every cycle - a per-PROCESS "
"this' a different question from 'is this site tripped'",
len(_notes2) == 1)
# SAFETY-34: a Core-ONLY restart. The add-on process lives on (measured on
# TEST-23), HA's memory is wiped, so the SAME process must re-assert the card.
import app.main as _main_mod # noqa: E402
_real_mono, _clock = _main_mod._mono, [_main_mod._mono()]
_main_mod._mono = lambda: _clock[0]
try:
_h3 = _CircHass(a_w=0.0, b_w=0.0)
_b.hass = _h3
asyncio.run(_b.check_circulating())
_early = [c for c in _h3.calls if c[0] == "persistent_notification"]
_clock[0] += _main_mod.REANNOUNCE_S
asyncio.run(_b.check_circulating())
_late = [c for c in _h3.calls if c[0] == "persistent_notification"]
finally:
_main_mod._mono = _real_mono
check("SAFETY-34: inside REANNOUNCE_S the same process does not re-raise - no "
"storm on the event bus", len(_early) == 0)
check("SAFETY-34: a Core-only restart wipes the card and the add-on process "
"survives it, so after REANNOUNCE_S the SAME process re-asserts it",
len(_late) == 1
and _late[0][2]["notification_id"] == "goodwe_circulating_power")
print()
print("6a. AC 4: THE ALARM NAMES WHICH PACKS, AND WHICH WAY ROUND")
@@ -683,6 +683,72 @@ except vol.Invalid as e:
str(e))
print("\n== H. TEL-14: the SHAPE of a per-entity PV sign option ==")
# Four candidate shapes, each against a 0.12.0 blob (`pv_entities` set, no new
# key). Transcript and decision: DECISIONS/TEL-14-pv-sign.md.
PV12 = {"pv_entity": "", "pv_entities": ["sensor.pv_inverter", "sensor.pv_meter"]}
_pv12 = MERGER.merge(copy.deepcopy(defaults), copy.deepcopy(PV12))
_nk = "pv_invert_entities"
def _ui_of(sch, name):
return [e for e in UiOptions(None)(sch) if e.get("name") == name]
# (a) a `-` prefix on a list item, under the shipped `- str`.
ok_a, out_a = validate(dict(_pv12, pv_entities=["sensor.pv_inverter",
"-sensor.pv_meter"]))
show("(a) PREFIX: `-sensor.pv_meter` validates under the shipped `- str` - "
"Supervisor does not look inside the string, so the sign would live in a "
"syntax that only the description text explains",
ok_a and out_a.get("pv_entities") == ["sensor.pv_inverter",
"-sensor.pv_meter"],
"" if ok_a else out_a)
# (b) a parallel list - THE SHIPPED SHAPE.
ok_b, out_b = validate(_pv12)
show("(b) ⭐ PARALLEL LIST, SHIPPED: the 0.12.0 blob (no `pv_invert_entities` "
"key) validates unchanged and the new key defaults to []",
ok_b and out_b.get(_nk) == []
and out_b.get("pv_entities") == PV12["pv_entities"],
"" if ok_b else out_b)
ok_b2, out_b2 = validate(dict(_pv12, **{_nk: ["sensor.pv_meter"]}))
show("...and one entity marked inverted validates",
ok_b2 and out_b2.get(_nk) == ["sensor.pv_meter"], "" if ok_b2 else out_b2)
ok_b3, out_b3 = validate({k: v for k, v in defaults.items() if k != _nk})
show("⭐ ...and the shipped `options:` block with ONLY `pv_invert_entities` "
"removed is REFUSED BY NAME - its `[]` default is load-bearing, as "
"`pv_entities: []` is",
(not ok_b3) and f"Missing option '{_nk}' in root" in str(out_b3), out_b3)
_ui_b = _ui_of(schema, _nk)
show("...and the Configuration tab renders it as a REPEATABLE string field "
"with its own top-level (translated) label",
len(_ui_b) == 1 and _ui_b[0].get("multiple") is True
and _ui_b[0].get("type") == "string", json.dumps(_ui_b))
# (c) a list of dicts - on `pv_entities` itself, and as a new key.
_s_dicts = dict(schema, pv_entities=[{"entity": "str", "invert": "bool?"}])
ok_c, out_c = validate_with(_s_dicts, _pv12)
show("(c) LIST OF DICTS ON `pv_entities`: the STRINGS a 0.12.0 install stored "
"are REFUSED - that shape would stop the add-on starting on upgrade",
(not ok_c) and "pv_entities" in str(out_c), out_c)
_s_src = dict(schema, pv_sources=[{"entity": "str", "invert": "bool?"}])
ok_c2, out_c2 = validate_with(_s_src, dict(_pv12, pv_sources=[]))
_ui_c = _ui_of(_s_src, "pv_sources")
show("(c2) ...as a THIRD key it validates, but renders as a type-schema "
"repeatable section whose per-entry keys reach the screen RAW "
"(`entity`, `invert`) on this frontend - see section F",
ok_c2 and len(_ui_c) == 1 and _ui_c[0].get("type") == "schema"
and _ui_c[0].get("multiple") is True,
json.dumps(_ui_c)[:200] if ok_c2 else out_c2)
# (d) one global bool.
_s_bool = dict(schema, pv_invert="bool")
ok_d, out_d = validate_with(_s_bool, dict(_pv12, pv_invert=False))
show("(d) GLOBAL `pv_invert: bool` validates too - it loses on SEMANTICS (one "
"sign for a mixed roster), not on the schema", ok_d, "" if ok_d else out_d)
# ⚠️ THE EXIT CODE IS PART OF THE INSTRUMENT. Without it the probe prints FAIL
# and still succeeds, and a transcript is only evidence if a wrong answer is
# distinguishable from a right one by something other than reading it.
+4 -1
View File
@@ -86,10 +86,13 @@ configuration:
description: "Whether the RS485 emergency stop is physically installed. It only drives the warning banner on the status page; it changes no control behaviour."
pv_entity:
name: "Hardware · PV production entity (W)"
description: "Optional, and MEASUREMENT ONLY - it changes no control behaviour whatsoever. Point it at your solar inverter's own power sensor (any brand Home Assistant reads; it does not have to be on the RS485 bus) and the add-on records production beside the grid and battery figures, so a day of unstored surplus can be told apart from a day with no sun. POSITIVE MUST MEAN PRODUCING. The unit is read from the entity itself - W, kW and the rest of Home Assistant's power units - so a sensor with no unit is refused rather than guessed at, and the status page says so. Leave it empty and nothing is read, nothing is published and nothing is shown."
description: "Optional, and MEASUREMENT ONLY - it changes no control behaviour whatsoever. Point it at your solar inverter's own power sensor (any brand Home Assistant reads; it does not have to be on the RS485 bus) and the add-on records production beside the grid and battery figures, so a day of unstored surplus can be told apart from a day with no sun. POSITIVE MUST MEAN PRODUCING - if yours reads negative while producing, list it under 'sign is reversed' below. The unit is read from the entity itself - W, kW and the rest of Home Assistant's power units - so a sensor with no unit is refused rather than guessed at, and the status page says so. Leave it empty and nothing is read, nothing is published and nothing is shown."
pv_entities:
name: "Hardware · PV production entities, one per inverter (W)"
description: "Optional, and MEASUREMENT ONLY - it changes no control behaviour whatsoever. Use this instead of the single entity above when your roof has SEVERAL solar inverters: add one row per inverter, pointing at each one's own power sensor, and the add-on records the SITE total. Each entity's own unit is read, so a kW inverter beside a W one adds up correctly. ⚠️ SETTING THIS IGNORES THE SINGLE ENTITY ABOVE - clear that one when you fill this in, or you will see a caution on the status page saying so. ⚠️ AND IF ANY ONE OF THESE STOPS REPORTING THERE IS NO SITE TOTAL: the sensor goes to 'unknown' and the history records a gap, rather than publishing the sum of the ones that did answer. Two inverters out of three add up to a smaller number that looks exactly like a real one, and a week later that reads as 'there was less sun than there was' - which is the one conclusion this recording exists to test. The status page names which entity is missing, why, and what the others reported. Leave it empty and nothing is read, nothing is published and nothing is shown."
pv_invert_entities:
name: "Hardware · PV entities whose sign is reversed"
description: "Optional, MEASUREMENT ONLY. Some sensors - typically a kWh meter or a power clamp in the PV circuit - read NEGATIVE while producing and a few watts POSITIVE at night. Add each such entity here, spelled exactly as it is above, and its sign is flipped before it is added up; leave the others out. The status page marks every flipped entity. History recorded before you set this keeps the old sign."
meter_source:
name: "Meter · Where the meter reading comes from"
description: "'off' keeps the single Home Assistant entity below, which is what an existing installation runs on until you choose otherwise. ha_dsmr subscribes to the DSMR integration; mqtt_p1 reads an MQTT topic; ha_signed reads one signed entity, which is what a HomeWizard P1 publishes; homewizard_local polls the meter's own local API and skips Home Assistant entirely. ⚠️ Only homewizard_local can tell 'the meter has not answered' apart from 'the value has not changed', so it is the only source on which the frozen-meter alarm means anything."
+4 -1
View File
@@ -66,10 +66,13 @@ configuration:
description: "Of de RS485-noodstop fysiek geïnstalleerd is. Dit stuurt alleen de waarschuwingsbalk op de statuspagina aan en verandert niets aan de regeling."
pv_entity:
name: "Hardware · Zonneproductie-entiteit (W)"
description: "Optioneel, en UITSLUITEND EEN METING - het verandert niets aan de regeling. Verwijs naar de vermogenssensor van je omvormer (elk merk dat Home Assistant kan lezen; hij hoeft niet op de RS485-bus te zitten) en de add-on registreert de productie naast de meter- en batterijwaarden, zodat een dag met niet-opgeslagen overschot te onderscheiden is van een dag zonder zon. POSITIEF MOET PRODUCEREN BETEKENEN. De eenheid wordt van de entiteit zelf gelezen - W, kW en de overige vermogenseenheden van Home Assistant - dus een sensor zonder eenheid wordt geweigerd in plaats van geraden, en de statuspagina zegt waarom. Laat leeg en er wordt niets gelezen, niets gepubliceerd en niets getoond."
description: "Optioneel, en UITSLUITEND EEN METING - het verandert niets aan de regeling. Verwijs naar de vermogenssensor van je omvormer (elk merk dat Home Assistant kan lezen; hij hoeft niet op de RS485-bus te zitten) en de add-on registreert de productie naast de meter- en batterijwaarden, zodat een dag met niet-opgeslagen overschot te onderscheiden is van een dag zonder zon. POSITIEF MOET PRODUCEREN BETEKENEN - leest de uwe negatief tijdens productie, zet hem dan ook bij 'teken omgekeerd' hieronder. De eenheid wordt van de entiteit zelf gelezen - W, kW en de overige vermogenseenheden van Home Assistant - dus een sensor zonder eenheid wordt geweigerd in plaats van geraden, en de statuspagina zegt waarom. Laat leeg en er wordt niets gelezen, niets gepubliceerd en niets getoond."
pv_entities:
name: "Hardware · Zonneproductie-entiteiten, één per omvormer (W)"
description: "Optioneel, en UITSLUITEND EEN METING - het verandert niets aan de regeling. Gebruik dit in plaats van de losse entiteit hierboven wanneer uw dak MEERDERE zonne-omvormers heeft: voeg één rij per omvormer toe, elk verwijzend naar haar eigen vermogenssensor, en de add-on registreert het totaal van de installatie. De eenheid van elke entiteit wordt afzonderlijk gelezen, dus een omvormer in kW naast een in W telt correct op. ⚠️ ALS U DIT INVULT WORDT DE LOSSE ENTITEIT HIERBOVEN GENEGEERD - maak die leeg, anders verschijnt er een waarschuwing op de statuspagina die dat meldt. ⚠️ EN ALS ÉÉN VAN DEZE ENTITEITEN NIETS MEER DOORGEEFT, IS ER GEEN TOTAAL: de sensor gaat naar 'unknown' en de geschiedenis bewaart een gat, in plaats van de som van de entiteiten die wél antwoordden te publiceren. Twee omvormers van de drie tellen op tot een kleiner getal dat precies op een echt getal lijkt, en een week later leest dat als 'er was minder zon dan er was' - net de conclusie die deze registratie moet kunnen testen. De statuspagina noemt welke entiteit ontbreekt, waarom, en wat de andere doorgaven. Laat leeg en er wordt niets gelezen, niets gepubliceerd en niets getoond."
pv_invert_entities:
name: "Hardware · Zonneproductie-entiteiten met omgekeerd teken"
description: "Optioneel, UITSLUITEND EEN METING. Sommige sensoren - meestal een kWh-meter of een stroomtang in het PV-circuit - lezen NEGATIEF tijdens productie en 's nachts enkele watt POSITIEF. Zet elke zulke entiteit hier, exact gespeld zoals hierboven, en haar teken wordt omgedraaid vóór het optellen; laat de andere weg. De statuspagina markeert elke omgedraaide entiteit. Geschiedenis van vóór deze instelling behoudt het oude teken."
meter_source:
name: "Meter · Waar de meterstand vandaan komt"
description: "'off' houdt de losse Home Assistant-entiteit hieronder aan, waar een bestaande installatie op draait tot u iets anders kiest. ha_dsmr luistert mee met de DSMR-integratie; mqtt_p1 leest een MQTT-topic; ha_signed leest één entiteit met teken, wat een HomeWizard P1 publiceert; homewizard_local bevraagt de lokale API van de meter zelf en slaat Home Assistant helemaal over. ⚠️ Alleen homewizard_local kan 'de meter heeft niet geantwoord' onderscheiden van 'de waarde is niet veranderd', en is dus de enige bron waarop het alarm voor een vastgelopen meter iets betekent."