@@ -2,6 +2,266 @@
|
||||
|
||||
## Unreleased
|
||||
|
||||
**Inverter B's rating is 4600 W, FROM ITS DATASHEET, and every documented copy
|
||||
of it now says so (SPIKE-04a).** Three places stated B's rating — `config.yaml`'s
|
||||
commented roster example, `DOCS.md`'s, and `tools/supervisor_shape_probe.py`'s
|
||||
"a blob an operator would POST" — and all three said **3000 W**, a number that
|
||||
was never measured, never read off a datasheet, and simply wrong. The owner
|
||||
supplied B's model and serial on 2026-09-04: a **GoodWe GW5048D-ES**, serial
|
||||
`55048ESU22AW0992`, max charging and discharging power **4600 W**. No control
|
||||
behaviour changes here; this is documentation and its pin.
|
||||
|
||||
* **Serial characters 6-8 read `ESU`** → platform 105, AA55, the supported set.
|
||||
Not `ESN`/`ESC` (ES G2, platform 745). SPIKE-01 does not gate this site.
|
||||
⚠️ A passed platform gate is **not** a proven control surface: `specs.md`
|
||||
already calls other platform-105 serials *"same protocol family; untested
|
||||
silicon"*, and this repo's `0x056E`/`0x056F` map was reverse-engineered from a
|
||||
passive tap on **one BPS unit**. That check is the bench half of SPIKE-04.
|
||||
* **⚠️ 4600 W IS FROM A DATASHEET AND IS NOT A MEASUREMENT, and one ambiguity is
|
||||
recorded rather than guessed.** The datasheet prints it under *Battery Input
|
||||
Data*, so it is probably **DC**, while `max_w` is graded against `0x0518` —
|
||||
the inverter's own **AC** power. If it is DC the AC ceiling is nearer
|
||||
4600 × 0.94 ≈ **4324 W**, and the charge direction moves the other way
|
||||
(≈ 4894 W drawn AC-side). **Neither reading is written in as fact.**
|
||||
SAFETY-20's `min(max_w, dev_max)` already bounds it correctly under either,
|
||||
once `dev_max` is read off the unit — so `max_w: 4600` is what to configure
|
||||
today. `goodwe/NOTES.md` §1.1b carries the full record, with the date and the
|
||||
method on every figure.
|
||||
* **A NEW CHECK, BECAUSE A DOCUMENTATION FIX WITHOUT ONE DRIFTS AGAIN.**
|
||||
`test_validate.py` now pins all three documented rosters: they must be
|
||||
findable, they must agree, and they must say **4600**. It also grades the
|
||||
**provenance beside the number** — the datasheet it came from, the `0x0518`
|
||||
it is graded against, and the 4324 W the DC reading would make it — **within
|
||||
2500 characters of the roster, not file-wide.** The first version searched
|
||||
whole files and was already vacuous on two of them, because `0x0518` appeared
|
||||
in `config.yaml` and `DOCS.md` for unrelated reasons before this card: a
|
||||
check whose data could not reach the failure it named, in the file that
|
||||
exists to complain about those. Four mutations were run against the fixed
|
||||
version — the probe back to 3000 (0-byte delta), the `DOCS.md` caveat
|
||||
deleted, `config.yaml` alone "corrected" to 4324 (0-byte delta), and the
|
||||
probe's entity renamed so the regex finds nothing — and all four are red.
|
||||
* **THE TEST FIXTURES KEEP 3000 W ON PURPOSE, AND NOW SAY WHY AT THE LINE.**
|
||||
`test_inverter.py`, `test_maintenance.py`, `test_peakguard.py` and
|
||||
`test_watchdog.py` build a second inverter at 3000 W against A's 5000 W. The
|
||||
only property those checks consume is that B's number is **unmistakably** not
|
||||
A's, and the real pair is a **400 W** gap — narrower than `slew_w`, inside the
|
||||
range where an off-by-one-unit bug and ordinary control arithmetic produce
|
||||
indistinguishable numbers. Collapsing them onto the real values would buy
|
||||
realism those checks do not use and cost them their separating power, which
|
||||
is the defect `test_peakguard.py`'s own §10g precondition exists to prevent.
|
||||
They are **illustrative, not B's rating, and no longer a placeholder for it**.
|
||||
* **Two consequences with numbers, recorded in `goodwe/NOTES.md` §1.1b for the
|
||||
cards that own them.** At 94 % battery-to-AC a round trip is ≈ 88 %, so A
|
||||
charging 3 kW while B discharges 3 kW burns ≈ **360 W continuously** with the
|
||||
meter at zero — SAFETY-31 argues its threshold from *"a few watts"* and has no
|
||||
figure. And **< 13 W night self-consumption per unit** (≈ 26 W for two,
|
||||
≈ 0.6 kWh/day), which nothing in this add-on accounts for anywhere.
|
||||
* **The site is asymmetric in opposite directions:** A = 5000 W / 15.36 kWh
|
||||
nominal, B = 4600 W / 20.48 kWh — ~33 % more energy, ~8 % less power. No
|
||||
stability implication (ARCH-01's ḡ = Σαᵢgᵢ is a convex combination), but a
|
||||
full recalibration of B moves 33 % more energy and **MAINT-05's 12 h `drain`
|
||||
phase timeout was derived on A**; it should be re-checked against B rather
|
||||
than assumed to carry.
|
||||
|
||||
**Every pack is recalibrated on its own schedule, and only one moves power at a
|
||||
time (MAINT-05).** §12's monthly cycle drains a pack to empty and refills it to
|
||||
true its coulomb counter. There was exactly one `Maintenance` state machine and
|
||||
one un-namespaced history, so at two packs **only the first was ever
|
||||
recalibrated** and the second's counter drifted forever — and nothing prevented
|
||||
the cycle draining pack A while the loop or arbitrage charged pack B, which is
|
||||
two power-moving phases on one grid connection pulling against each other.
|
||||
|
||||
* **ONE `Maintenance` PER ROSTER ENTRY**, each with its own schedule, phase and
|
||||
history under `unit/<name>/...`. `store.migrate_maint_keys()` moves an
|
||||
existing install's flat history into the first pack's namespace under
|
||||
`migrate_unit_keys()`'s three rules — shared in code, not restated — with the
|
||||
same read-back postcondition, and the flat keys are kept **live** as the
|
||||
rollback view so a downgrade finds a current history rather than one dated
|
||||
migration day.
|
||||
* **ONE MAINTENANCE SLOT PER SITE.** At most one pack may be in a power-moving
|
||||
phase (`drain`, `charge` **and** `hold` — `charge` is in the set because a
|
||||
pack pulled full from the grid beside a pack exporting to empty is 4 kW
|
||||
circulating with the meter at zero). The holder is **derived** from the packs'
|
||||
own stored phases, not persisted, so a restart mid-drain re-derives it. When
|
||||
several packs are due in the same hour the slot goes to the one that has gone
|
||||
**longest without a completed cycle**; roster order breaks a numeric tie and
|
||||
nothing else. Nothing preempts a cycle in flight.
|
||||
* **THE DEFERRED PACK IS NOT STARVED AND IS NOT A FAULT.** A deferral does not
|
||||
stamp `last_start_attempt` (that is the 90 min post-abort cooldown, inside a
|
||||
60 min start hour), and does not move the phase, so neither the 12 h `drain`
|
||||
nor the 36 h `charge` timeout — *"the battery is not following commands"* —
|
||||
can be reached by waiting. It says WAITING, names the pack it waits for, and
|
||||
recalibrates at the next start hour; a test drives the winner's whole cycle
|
||||
and observes it start.
|
||||
* **THE SCHEDULE IS NOT STAGGERED BY CONSTRUCTION.** The interlock defers and
|
||||
the stagger is what comes out of it: one contested month separates two packs
|
||||
by one cycle length and they stay separated. `DECISIONS/MAINT-05-per-pack-maintenance.md`
|
||||
§3 carries the argument.
|
||||
* **`validate.py` rule 6 now grades `maintenance_charge_w` against the WEAKEST
|
||||
cap on the roster**, like rule 5. Its own comment said it would have to move
|
||||
the day `maint_unit` stopped being `inverters[0]`; that day is this card. It
|
||||
refuses configurations that used to start — a 3000 W charge beside a 2000 W
|
||||
pack that is now recalibrated too — which is the `lo > hi` contradiction rule
|
||||
6 exists to refuse, caught when the config is written. Identical at N=1.
|
||||
* **AT A ROSTER OF ONE, NOTHING CHANGES**, and it is asserted rather than
|
||||
assumed: the state file keeps the flat keys and gains none, the migration does
|
||||
not run, the four cycle events are the shipped strings character for
|
||||
character, and the status banner is the bare phase with no pack name.
|
||||
* **THE MIGRATION IS GRADED AGAINST THE ROSTER, NOT AGAINST THE NAME IT WAS
|
||||
HANDED** (fix round). `migrate_maint_keys()` takes the roster rather than a
|
||||
pack count and `_verify_moves()` checks the namespace it wrote against the
|
||||
names the machines actually read. A postcondition that reads back the
|
||||
namespace it was given cannot detect being given the wrong one: handed
|
||||
`inverter.UNIT_A` on a roster of `["garage", "shed"]`, the first version of
|
||||
this card wrote all four keys under `unit/inverter-a/...`, read all four back
|
||||
equal, reported **verified**, and stamped `maint_schema_version` — so both
|
||||
packs came up believing they had never been recalibrated and the next start
|
||||
skipped the migration too. That is now `misdirected`: not `ok`, the marker is
|
||||
**not** written, and the next start re-runs and recovers (rule 1 makes the
|
||||
re-run a no-op). `build_roster()` numbers a nameless roster entry
|
||||
`inverter-1`, so `inverter-a` is not even the fallback for a declared roster.
|
||||
Every two-pack fixture that could see this now names its first pack
|
||||
`garage`; with them all called `inverter-a`, `self.inverters[0].name` and
|
||||
`UNIT_A` were the same string and the swap left all 19 suites green.
|
||||
* **AND THE REFUSAL NOW SURVIVES THE NEXT START** (second fix round). The fix
|
||||
above graded only the keys it had just *written*, so it refused exactly once:
|
||||
measured at Controller level over one persisted store, roster
|
||||
`["garage", "shed"]`, with the call site still wrong on both starts —
|
||||
construction 1 `ok=False misdirected=4 moved=4 kept=0 marker=<absent>`,
|
||||
construction 2 `ok=True misdirected=0 moved=0 kept=4` and the marker
|
||||
**stamped**. On the second start rule 1 finds the wrong keys already there and
|
||||
routes all four to `kept`, so `moved` is empty and the roster loop grades
|
||||
nothing — and start 3 skips the migration forever, *including after the call
|
||||
site is fixed*. Loud-and-recoverable became silent-and-permanent after one
|
||||
restart. `_verify_moves()` now grades `set(moved) | set(kept)`; both lists are
|
||||
built from the same `unit` argument, so grading `kept` grades the same
|
||||
namespace decision. `test_maintenance.py` part **9c** drives two starts with
|
||||
the same wrong unit over one store — the shape nothing in the suite had, since
|
||||
9b measured recovery along the path where the operator has *already* fixed the
|
||||
call site.
|
||||
* **AND THE MARKER GATE IS PINNED ON BOTH GUARDS.** `if rep.ok:` is
|
||||
`not lost and not misdirected`, and the mutation `if rep.ok or rep.kept:`
|
||||
stamped the marker on a migration that **lost a month of history** with all 19
|
||||
suites green. Part **9d** is the fixture that separates the two guards: two
|
||||
keys already namespaced (`kept` non-empty) and two whose write the store
|
||||
drops (`lost` non-empty), `misdirected` empty throughout.
|
||||
* ⚠️ **AND THE SAME MUTATION ONE FUNCTION UP WAS A SURVIVOR, FOUND HERE AND
|
||||
CLOSED.** `migrate_unit_keys()` — SAFETY-02's **latch** migration — gates its
|
||||
own marker on `rep.ok` too, and every check that reached that gate ran on a
|
||||
store where nothing was namespaced yet, so `rep.kept` was empty in all of
|
||||
them. `if rep.ok or rep.kept:` there stamps `schema_version` on a migration
|
||||
that **dropped the latch**: the guard is off, the file still says
|
||||
`sign_tripped: true`, and the next start skips the migration that would have
|
||||
re-armed it. Measured a survivor of all 19 files; now red on
|
||||
`test_inverter.py` part 10, which drops the `sign_tripped` write beside an
|
||||
already-namespaced `sign_reason`. No source change — the shipped gate was
|
||||
right; nothing could see it.
|
||||
* ⚠️ **FOUND, RECORDED, NOT FIXED (SECOND ONE).** `migrate_unit_keys()` —
|
||||
SAFETY-02's latch migration — has the identical hole and it costs a **guard**
|
||||
rather than a history. It runs before `build_roster()` (each `Inverter`
|
||||
restores its latch in its constructor), so it is handed the constant `UNIT_A`
|
||||
and there is no roster to grade against. On a declared roster a pre-DEV-02
|
||||
`sign_tripped: true` lands under `unit/inverter-a/sign_tripped`, which no unit
|
||||
reads — and `_grade_store_migration()`, whose job is to re-arm exactly this,
|
||||
is **defeated by the key the defect wrote**: its "is anything namespaced
|
||||
latched" test is satisfied by the misdirected value itself. Fixing it means
|
||||
naming the migration's target from the config before any `Inverter` exists,
|
||||
which is `inverter.py` and SAFETY-02's semantics, with its own battery.
|
||||
Measured and pinned as a running check (`test_maintenance.py` part 13), whose
|
||||
assertions state the WRONG behaviour on purpose.
|
||||
* ⚠️ **FOUND, RECORDED, NOT FIXED.** A maintenance drain **pins** its pack while
|
||||
the loop's target is a **site** claim, so when the site target is below the
|
||||
pin the only split asks the sibling to charge against the drain and
|
||||
`allocator.plan()` refuses it — the site parks at 0 W and the pack's 12 h
|
||||
timeout would eventually report *"drain stuck"* about a healthy battery.
|
||||
Pre-existing on `release/1.0` at `2d025ee` with the unit names swapped; fixing
|
||||
it means changing what the loop's target means while a unit is pinned, which
|
||||
is loop and allocator territory. Pinned as a running check
|
||||
(`test_maintenance.py` part 12) so it cannot be forgotten.
|
||||
|
||||
**At two inverters the sign watchdog stops comparing one unit against the whole
|
||||
site meter, and becomes two checks instead of one (SAFETY-30).**
|
||||
`disagrees(commanded_w, grid_w, ...)` compared the command **this controller put
|
||||
on ONE actuator** against **what the whole site** is exchanging with the network.
|
||||
At a roster of one those are two views of the same thing - §6.2's identity - and
|
||||
that is what makes the check sound and what earned it the best record in the
|
||||
safety table. At two they are not, and it fails **in both directions**: inverter
|
||||
A commanded −1500 W while the meter reads +1500 W is evidence of nothing when
|
||||
inverter B is discharging 3000 W exactly as told, and - worse - a unit genuinely
|
||||
driving the wrong way is **MASKED** by a sibling that covers for it, because the
|
||||
site figure nets. No threshold recovers that; the summation destroys the
|
||||
evidence.
|
||||
|
||||
* **PER UNIT: each inverter's own share against its OWN measured power**
|
||||
(`Inverter.batt`, holding register 0x0518, per-instance since DEV-02).
|
||||
Conclusion: *the actuator I am driving is not doing what I told it* - evidence
|
||||
about one device, so the remedy stays the per-unit `failsafe` SET that
|
||||
`arbiter.CLAIM_SCOPE` has classified `SCOPE_UNIT` since it was written. That
|
||||
entry read *"the evidence is site-wide and the remedy is not"*; after this card
|
||||
the first half is simply true. Verified by making one unit reverse while its
|
||||
sibling covers it at the meter: the shipped comparison is false on **0 of 14**
|
||||
cycles while the new one convicts that unit on every one, and only that unit is
|
||||
parked.
|
||||
* **SITE: the SUM of the standing commands against the meter**, as a new
|
||||
`sign_site` SET at `P_SAFETY` on the site actuator, latched under flat
|
||||
`site_sign_tripped` / `site_sign_reason`. This is the fault the 2026-08-20
|
||||
capture contains and **no per-unit check can see it**, because every inverter
|
||||
is faithfully executing its share - what is wrong is the number they were
|
||||
given. It stops every inverter and the banner names the site rather than an
|
||||
inverter, so nobody is sent to swap the wrong box.
|
||||
* **⚠️ Different questions from SAFETY-31, and the PR and the decision record
|
||||
both say which.** `circulation.py` compares the units **against each other**
|
||||
and catches two inverters pushing *through* each other, which nets to zero at
|
||||
the meter and which no single command is evidence about. This compares each
|
||||
unit against **its own command**. They overlap in exactly one scenario - a unit
|
||||
reversing while its sibling pulls the other way - and `test_watchdog.py`
|
||||
asserts on that fixture that both fire and what each concludes. It is also not
|
||||
the saturation freeze: that is a magnitude test (`|command − measured| >
|
||||
500 W`) that shapes the loop and fires on a merely saturated unit; this is a
|
||||
direction test that latches and parks one.
|
||||
* **⚠️ All four thresholds RE-DERIVED at two inverters - one carried with a
|
||||
justification, one refused.** 1890 closed-loop runs in which nothing is faulty,
|
||||
over the whole range `config.yaml` accepts for `gain` and `slew_w`, across load
|
||||
reversals with write staggers and flapping loads, **run at both rosters so the
|
||||
N=1 arm is the control.** `unit_sign_disagree_w: 250` is `saturation_w / 2`, so
|
||||
the smallest divergence this can see is exactly the gap at which the control
|
||||
law itself already says the inverter is not following; `unit_sign_disagree_s:
|
||||
85` is 8.5× the worst legitimate opposition those runs produce (10.0 s), 2.8×
|
||||
the firmware's own 30 s link veto and under half the site hold.
|
||||
`site_sign_disagree_w: 300` is **carried** - its argument is the meter's noise
|
||||
floor and the deadband, and the roster touches neither. **`site_sign_disagree_s`
|
||||
is NOT: 180 s would have shipped a false trip.** The worst legitimate crossing
|
||||
at 300 W is 110 s with one inverter and **215 s with two**, because the command
|
||||
must travel a rail that is the roster sum at a `slew_w` that is not - reachable
|
||||
at `gain: 0.05`, `slew_w: 50` and a 2.2 kW load reversal, all schema-legal.
|
||||
325 s is 1.51× that, inside the 900 s billing quarter and inside every episode
|
||||
of the fault day. See `DECISIONS/SAFETY-30-per-unit-sign.md`.
|
||||
* **⚠️ At ONE inverter this changes nothing, and "nothing" is asserted rather
|
||||
than assumed.** The two questions are the same sentence at a roster of one, so
|
||||
only the detector that shipped is armed: same comparison against the meter,
|
||||
same 300 W / 180 s, same reason string byte for byte, same namespaced latch and
|
||||
flat rollback mirror, same `failsafe` claim, same banner, same single status
|
||||
row - and the site detector's window is never so much as opened.
|
||||
`unit_sign_disagree_*` and `site_sign_disagree_*` do nothing on a
|
||||
one-inverter install.
|
||||
* **The threshold WIRING is pinned, not just the threshold values.** Review
|
||||
found that `arm(self.sign_cfg if one else self.unit_sign_cfg, ...)` could be
|
||||
collapsed to `arm(self.sign_cfg, ...)` — arming every unit with the
|
||||
meter-facing pair instead of the re-derived per-unit one — with all 19 test
|
||||
files still green, because nothing at a roster of two read `sign_wd.cfg` and
|
||||
the trips in the fixture happen under either pair. `test_watchdog.py` part 3
|
||||
now asserts the pair and the instrument on **every** detector against
|
||||
literals, and the fixture's three threshold pairs were made pairwise distinct
|
||||
in both coordinates so that a hold delivered from the wrong pair cannot
|
||||
compare equal to the right one. M14–M16 in
|
||||
`DECISIONS/SAFETY-30-per-unit-sign.md` §5.
|
||||
* **Known and recorded rather than fixed:** the site comparison is defeated by a
|
||||
square-wave load whose half period is about one control cycle, which holds it
|
||||
opposed for ~1000 s at *both* rosters. The N=1 control arm is what says this is
|
||||
a property of comparing a lagged command against a meter and has nothing to do
|
||||
with the second inverter, so it is not acted on here - it wants an alternation
|
||||
test, not a number, and a card of its own.
|
||||
|
||||
**An operator can declare a second inverter, and the shape was measured against
|
||||
the Supervisor rather than assumed (CFG-04).** DEV-02 made rating, SoC,
|
||||
watchdogs, heartbeat and store keys per-instance, so the code no longer assumed
|
||||
|
||||
@@ -0,0 +1,388 @@
|
||||
# MAINT-05 — one recalibration per pack, one at a time, and what the card left open
|
||||
|
||||
**Status: DECIDED 2026-09-04.** There is one `Maintenance` per roster entry,
|
||||
each with its own schedule, phase and history. The site holds exactly **one
|
||||
maintenance slot**: at most one pack may be in a power-moving phase, the slot is
|
||||
derived from the packs' own stored phases rather than persisted separately, and
|
||||
when several packs are due in the same hour it goes to the one that has gone
|
||||
**longest without a completed cycle**. The schedule is **not** staggered by
|
||||
construction — the interlock defers, and the stagger emerges from it.
|
||||
|
||||
**Fix round 2026-09-04.** The store migration is now graded against the
|
||||
**roster** rather than against the unit name it was handed — see §2's
|
||||
*"The read-back postcondition is graded against the ROSTER"* — and the same
|
||||
hole in SAFETY-02's latch migration is recorded in §7.
|
||||
|
||||
Filed with MAINT-05. Card `6a9a9e8503872905f298d80a`.
|
||||
|
||||
---
|
||||
|
||||
## 0. What the card asked to be decided, and the answers
|
||||
|
||||
| the card's open question | the decision |
|
||||
|---|---|
|
||||
| §2 the arbitration | **one pack at a time; the other stays under the loop.** Nothing preempts a cycle in flight. |
|
||||
| §2 who wins when several are due | **the longest-waiting pack**, `last_completed` oldest first, `inf` for never-recalibrated. Roster order breaks a numeric tie and nothing else. |
|
||||
| §4 staggering | **not by construction.** The interlock defers the second pack; the stagger is what comes out of it. §3 below. |
|
||||
| AC 7 rule 6's `maint_unit` comment | **no, the first entry's cap is no longer right.** It grades against the weakest cap on the roster now, like rule 5. §4 below. |
|
||||
| the store layout at N=1 | **flat, unchanged.** The namespace appears the day the roster grows. §2 below. |
|
||||
|
||||
## 1. Why the slot is derived and not persisted
|
||||
|
||||
The holder is *"whichever pack's stored phase is not `idle`"* — a fact already on
|
||||
disk, written by the packs themselves in the per-pack history this card
|
||||
introduces. A `maint_slot_holder` key would be a **second opinion about the same
|
||||
thing**, and the two would disagree the first time the add-on was killed between
|
||||
writing the phase and writing the holder. Derived, a controller that comes back
|
||||
up mid-drain reads the drain and re-derives the holder from it; there is no
|
||||
recovery path to get wrong because there is no second fact.
|
||||
|
||||
`CHARGE` is in `POWER_MOVING` even though the control **loop** owns the setpoint
|
||||
in that phase, and that is the decision most likely to be "simplified" later.
|
||||
Pack A charging from the grid at 2000 W while pack B drains 2000 W to export is
|
||||
4 kW going round in a circle with the meter reading zero and both packs
|
||||
believing they are behaving — the circulating power [[SAFETY-31]] exists to
|
||||
detect, arriving as something this module can simply not do. `HOLD` is in the
|
||||
tuple for the other half of the sentence: it moves nothing, and it **owns the
|
||||
actuator**, so a second cycle starting under it would still be two
|
||||
recalibrations at once.
|
||||
|
||||
## 2. Why the store layout at a roster of one does not change
|
||||
|
||||
The maintenance keys are flat — `phase`, `phase_started`, `last_completed`,
|
||||
`last_start_attempt` — on every install since the add-on shipped. At one pack
|
||||
there is nothing for a namespace to distinguish that pack **from**: §6.2's
|
||||
identity, the same one `arbiter.actuator_for()` leans on when it routes every
|
||||
claim to the site actuator at N=1. So `Maintenance` is constructed with
|
||||
`unit=None` there, reads and writes the flat keys directly, and
|
||||
`migrate_maint_keys()` **returns without writing anything**. A one-inverter state
|
||||
file comes out of this card byte-identical, which is AC 6 and which
|
||||
`test_maintenance.py` part 10 asserts by driving a whole cycle and comparing the
|
||||
key set.
|
||||
|
||||
### The migration has its own marker, and that is not tidiness
|
||||
|
||||
`SCHEMA_VERSION` / `schema_version` is DEV-02's, and it is **monotone**: every
|
||||
install runs that migration exactly once. This one runs **only where the roster
|
||||
has more than one pack**, so a single counter could not express *"migrated on
|
||||
this site, deliberately not migrated on that one"* without lying to the next
|
||||
version that reads it — a one-inverter store would have to be pinned at the old
|
||||
number forever, and a genuine future v2 migration could then never be told apart
|
||||
from a site that simply never grew. `maint_schema_version` answers one question
|
||||
and answers it honestly.
|
||||
|
||||
The **three rules are shared in code**, not restated: `_move_flat_keys()` is
|
||||
rule 1 (never overwrite an existing namespaced value) and rule 2 (the flat keys
|
||||
stay in the file), `_verify_moves()` is the read-back postcondition, and the
|
||||
marker is written last. A second transcription of a migration is a second
|
||||
opinion about what "it landed" means.
|
||||
|
||||
### The read-back postcondition is graded against the ROSTER (fix round)
|
||||
|
||||
**A postcondition that reads back the namespace it was handed cannot detect
|
||||
being handed the wrong one.** That sentence is the whole finding, and this card
|
||||
shipped it broken.
|
||||
|
||||
`_verify_moves()` iterated `rep.moved` — the keys it had just written — and
|
||||
asked whether each read back equal. On a store where the write lands, it always
|
||||
does. So a migration handed a `unit` that is on no roster wrote four keys, read
|
||||
four keys back, set `verified = True`, and the caller stamped
|
||||
`maint_schema_version`. Every symptom of a clean migration, and an install's
|
||||
whole maintenance history parked under a name nothing will ever look up. And
|
||||
because the marker was stamped, **the next start skipped the migration too** —
|
||||
which is precisely the state `store.py`'s header says must never happen: a
|
||||
failed migration a later version treats as done.
|
||||
|
||||
Reproduced on the reviewer's roster, a house with a garage pack and a shed pack,
|
||||
carrying a flat `last_completed` of 2026-08-07:
|
||||
|
||||
| | `unit` the migration was handed | key written | pack 0 reads back | due now? |
|
||||
|---|---|---|---|---|
|
||||
| correct | `self.inverters[0].name` = `garage` | `unit/garage/last_completed` | `2026-08-07` | **False** |
|
||||
| wrong | `inverter.UNIT_A` = `inverter-a` | `unit/inverter-a/last_completed` | `None` | **True** |
|
||||
|
||||
`build_roster()` names a declared roster's entries **from the config**, and its
|
||||
fallback for a nameless entry is a **positional** `inverter-1` — so `inverter-a`
|
||||
is not the name of anything on a declared roster, not even by default.
|
||||
|
||||
**The remedy, and why this one.** `migrate_maint_keys()` now takes the **roster**
|
||||
in place of an `n_units` count (the count was `len(self.inverters)` at the only
|
||||
call site, so the roster carries it, and a count passed beside the names is a
|
||||
second opinion about how many packs there are). `_verify_moves()` grades the
|
||||
namespace it wrote against those names, and a unit that is not among them is
|
||||
reported as `misdirected` — a **different** failure from `lost`:
|
||||
|
||||
* `lost` is *the store took the write and dropped it* — a storage fault, and it
|
||||
has a harmless-default case (a write of `last_completed: None` loses nothing,
|
||||
because "absent" and "never recalibrated" are the same statement).
|
||||
* `misdirected` is *the store did exactly as it was told, by a caller that was
|
||||
wrong*. There is no harmless-default version of it: a write nobody reads is
|
||||
not information, whatever its value. So anything in it fails `ok` on its own.
|
||||
|
||||
And **`ok` gates the marker**, so a misdirected migration is not stamped and the
|
||||
next start runs it again. The argument for it is asymmetric: a re-run is
|
||||
recoverable — rule 1 makes it a no-op where keys did land, and rule 2 left the
|
||||
flat keys in the file to recover *from* — while a silent skip is not recoverable
|
||||
at all, because the store now claims the migration happened.
|
||||
|
||||
### ⚠️ THE PARAGRAPH ABOVE USED TO END HERE, AND AS IT STOOD IT WAS FALSE
|
||||
|
||||
**The refusal lasted exactly one start. The second start stamped the marker.**
|
||||
That is a correction to what the first fix round wrote down, not a new
|
||||
qualification of it, and it is recorded here because a decision document that
|
||||
states a guarantee the code does not provide is worse than one that says
|
||||
nothing.
|
||||
|
||||
`_verify_moves()` graded only `rep.moved`. Measured at Controller level over
|
||||
**one persisted store**, roster `["garage", "shed"]`, flat `last_completed`
|
||||
2026-08-07, with the call site still handing `inverter-a` on **both** starts:
|
||||
|
||||
```
|
||||
construction 1: ok=False misdirected=4 moved=4 kept=0 marker=<absent> (withheld)
|
||||
construction 2: ok=True misdirected=0 moved=0 kept=4 marker=1 (STAMPED)
|
||||
history parked under unit/inverter-a/…; marker stamped after ONE restart.
|
||||
```
|
||||
|
||||
On start 2 the same wrong call site finds the four keys it wrote already
|
||||
present, so **rule 1** — never overwrite a namespaced value — routes every one
|
||||
of them to `rep.kept`. `rep.moved` is empty, the roster-grading loop iterates
|
||||
over nothing, `misdirected` is empty, `ok` is True, the marker is stamped, and
|
||||
start 3 takes the `from_version >= MAINT_SCHEMA_VERSION` early return **forever
|
||||
— including after the call site is fixed**. Loud-and-recoverable became
|
||||
silent-and-permanent after one restart: exactly the state `store.py`'s header
|
||||
says must never happen, reached by the fix written to prevent it.
|
||||
|
||||
**The remedy is one line**, and it is sound by construction rather than by
|
||||
argument: grade `set(rep.moved) | set(rep.kept)`. Every entry in *both* lists is
|
||||
a `unit_key(unit, legacy)` built from the **same** `unit` argument, so grading
|
||||
`kept` grades the same namespace decision `moved` does. A correct call site's
|
||||
`kept` entries are under a roster name and pass; a wrong one cannot launder its
|
||||
namespace by having already written it. `migrate_unit_keys()` passes
|
||||
`roster=None` and returns before the loop, so it is unaffected.
|
||||
|
||||
**Why the check missed it, which is the part worth keeping.** Part 9b's recovery
|
||||
check was `migrate_maint_keys(_m5, ROSTER[0], ROSTER)` — the **corrected** name.
|
||||
It measures recovery along the one path where the operator has *already fixed
|
||||
the bug*. The real failure is a call site that is still wrong on the next start,
|
||||
and nothing in the 19 files called `migrate_maint_keys()` twice with the **same
|
||||
wrong** `unit`. The check was true, passed, and could not reach the failure its
|
||||
sentence named — MUTATION.md's third defect, this time sitting inside the fix
|
||||
written to close it. Part **9c** now drives two starts with the same wrong unit
|
||||
over one store, asserts the marker is still withheld on the second, and asserts
|
||||
the *shape* of the second report (`moved` empty, `kept` full) so it cannot
|
||||
quietly revert to 9b's path.
|
||||
|
||||
### The marker gate is `rep.ok` and nothing weaker — both guards, each pinned
|
||||
|
||||
`if rep.ok:` is `not lost and not misdirected`, and until this round only the
|
||||
`misdirected` half was reachable by a check that also had a non-empty `kept`.
|
||||
The mutation
|
||||
|
||||
```
|
||||
if rep.ok: -> if rep.ok or rep.kept:
|
||||
```
|
||||
|
||||
stamps the marker on a migration that **lost a month of history** — defeating
|
||||
the older, settled `lost` guard as well as the new one — and **all 19 suites
|
||||
were green on it**. Part **9d** is the fixture that separates them: two keys
|
||||
already namespaced (`kept` non-empty, so the mutant's `or` fires) and two keys
|
||||
whose write the store drops (`lost` non-empty, so `ok` is False), with
|
||||
`misdirected` empty throughout so the section cannot pass on the other guard by
|
||||
accident. Measured differential on it: shipped → marker absent; mutant → marker
|
||||
`1`, both reporting `ok=False lost=2 kept=2`.
|
||||
|
||||
**Why the fixtures had to change, and this is the part that got the card
|
||||
rejected.** Nothing in the repository could see whether any of the above was
|
||||
true, because `inverter.UNIT_A` **is** the string `"inverter-a"` and every
|
||||
two-pack fixture in `test_maintenance.py` named its first roster entry
|
||||
`inverter-a`. `self.inverters[0].name` and `UNIT_A` were therefore the same
|
||||
value in every check that existed, and swapping one for the other at the call
|
||||
site left **all 19 suites green**. MUTATION.md's third defect exactly — a check
|
||||
whose *data* cannot reach the failure it names — and the fifth consecutive card
|
||||
to carry it. Parts 9 and 11 now run on `["garage", "shed"]`, each behind a
|
||||
**precondition check** asserting that the first name is not `UNIT_A`, so an edit
|
||||
that makes them equal again goes red instead of making the claims vacuous.
|
||||
|
||||
### And the flat keys are kept LIVE, which is the half DEV-02 had to add later
|
||||
|
||||
Rule 2 originally said the flat keys are left in place and go stale. DEV-02
|
||||
amended it, for the sign latch, to *"left in place is not enough"* — and the
|
||||
same sentence holds for history. A fossil dated the day the second inverter was
|
||||
declared would hand a rolled-back single-FSM add-on a `last_completed` months
|
||||
old (it recalibrates a pack that does not need it) or a stale `phase` with a
|
||||
`phase_started` old enough to abort on the 12 h timeout the moment it comes up.
|
||||
So `UnitHistory` **mirrors the first pack's writes back onto the flat keys** for
|
||||
as long as the roster has more than one entry. Only the first pack: the flat
|
||||
spelling means `inverters[0]` on every install that has one, and a mirror from
|
||||
pack B would overwrite pack A's rollback view with pack B's phase.
|
||||
|
||||
## 3. Staggering: the interlock defers, and the stagger is the residue
|
||||
|
||||
Two packs on one monthly schedule are due in the same hour every month. The
|
||||
options were a stagger **by construction** — offset each pack's first cycle by
|
||||
`interval_days / N` — or **deferral**. Deferral, for three reasons:
|
||||
|
||||
1. **A constructed stagger cannot remove the need for the interlock.** A forced
|
||||
start, a commissioning cycle, an abort-and-retry, or a pack added mid-month
|
||||
desynchronises any static offset immediately, so the interlock has to be
|
||||
there anyway — and then the stagger is a second mechanism that must also be
|
||||
correct, for a case the first one already handles.
|
||||
2. **A deferral is observable and a stagger is not.** The deferred pack says, in
|
||||
the action log and on the status page, that it is waiting, which pack it is
|
||||
waiting for, and that it will run at the next start hour. A silent offset
|
||||
moves an operator's configured start day and explains nothing.
|
||||
3. **The stagger comes out of the deferral for free and then persists.** Pack A
|
||||
completes on day 1 and is next due on day 29; pack B, deferred, completes on
|
||||
day 2 and is next due on day 30. One contested month separates them by one
|
||||
cycle length and they stay separated.
|
||||
|
||||
**Starvation was the risk and it is closed at two points.** A deferral does
|
||||
**not** stamp `last_start_attempt` — that key is the post-abort cooldown, and at
|
||||
90 minutes inside a 60-minute start hour, stamping it would lock the deferred
|
||||
pack out of exactly the hour it is waiting for. And the winner is the
|
||||
longest-waiting pack rather than the first in the roster, so a pack that keeps
|
||||
aborting cannot monopolise the slot month after month while its sibling drifts —
|
||||
which is this card's own defect wearing a different costume.
|
||||
|
||||
**The deferral must not read as a fault.** §12's 12 h and 36 h phase timeouts
|
||||
mean *"the battery is not following commands"*. A deferred pack stays `IDLE`
|
||||
with `phase_started` untouched, so no timeout is reachable by waiting, and the
|
||||
line it logs says WAITING, names the pack it waits for and says it will run
|
||||
next — none of which any failure path in `maintenance.py` says.
|
||||
|
||||
## 4. Rule 6 (the card calls it rule 8): the first entry's cap is no longer right
|
||||
|
||||
`validate.py`'s rule 6 comment said, in as many words, that
|
||||
`maintenance_charge_w` was graded against `inverters[0]`'s cap because there was
|
||||
exactly one `Maintenance` and it could only ever recalibrate the first pack —
|
||||
and that taking `min()` would be an over-refusal, because it would refuse *"a
|
||||
5000 W pack being recalibrated beside a 2000 W sibling the cycle never
|
||||
touches"*. It closed: **"when `maint_unit` stops being `inverters[0]`, this line
|
||||
moves with it."**
|
||||
|
||||
It has stopped. Every pack is recalibrated on its own schedule, so **the sibling
|
||||
the cycle never touches does not exist** and the over-refusal argument has no
|
||||
subject. The shaping claim is filed on whichever pack is charging, so the cap
|
||||
that can contradict it is any cap on the roster and the one that contradicts it
|
||||
first is the smallest.
|
||||
|
||||
**This refuses configurations that used to start**, and that is the point rather
|
||||
than a side effect: `max_w` 5000 on pack A beside 2000 on pack B with
|
||||
`maintenance_charge_w` 3000 was correct while only pack A was ever recalibrated,
|
||||
and is now a cheap-window charge asking the arbiter for `hi = -3000` against a
|
||||
supervised `lo = -2000` — `lo > hi`, arbiter clause 3, 0 W, on the pack nobody
|
||||
was watching. Refused when it is **written**, which is rule 6's whole job. At a
|
||||
roster of one `min()` over one cap is that cap: same comparison, same message,
|
||||
same boundary.
|
||||
|
||||
## 5. The claim stays per-unit, and nothing here files a site claim
|
||||
|
||||
`arbiter.CLAIM_SCOPE` has classified `maintenance` as `SCOPE_UNIT` since it was
|
||||
written. Two FSMs mean two claims on two actuators, which the allocator consumes
|
||||
as per-unit intervals. [[ARCH-01]] is explicit that this must never become a
|
||||
site claim, because per-inverter constraints filed site-wide are the
|
||||
cross-inverter `lo > hi` contradiction at `arbiter.py:114`. The only line this
|
||||
card changed there is **which** roster entry the claim is filed on: the one whose
|
||||
state machine produced the result, rather than `inverters[0]`.
|
||||
|
||||
## 6. FOUND AND NOT FIXED: the site loop still contradicts a drain at N>=2
|
||||
|
||||
Measured while wiring this card, and **pre-existing on `release/1.0` at
|
||||
`2d025ee`** — the same drain filed on `inverters[0]` produces the identical
|
||||
refusal with the two unit names swapped.
|
||||
|
||||
The maintenance SET **pins** its pack. The loop's target is a **site** claim.
|
||||
When the site target is *below* the pin — a 2000 W drain while the house imports
|
||||
less than that, which is most of a night — the only split that sums to the site
|
||||
target asks the sibling to **charge** while the maintained pack **discharges**,
|
||||
and `allocator.plan()` refuses it by name as circulating power. The refusal is
|
||||
correct and fails safe: the whole site goes to 0 W with an `ARBITER: REFUSED`
|
||||
line in the action log.
|
||||
|
||||
**The consequence an operator would see is a misdiagnosis.** The pack is held at
|
||||
0 W while its state machine believes it is draining, so after 12 h the DRAIN
|
||||
timeout fires and reports *"drain stuck"* — §12's words for a battery that is not
|
||||
following commands. The battery is fine; the site refused to allocate.
|
||||
|
||||
**Why it is not fixed here.** The fix is to change what the site loop's target
|
||||
*means* while a unit is pinned — regulate the meter using only the unpinned
|
||||
packs — which is loop and allocator territory and changes the integrator's
|
||||
subject. MAINT-05 moves which pack is pinned and nothing else about it. It is
|
||||
pinned as a running check (`test_maintenance.py` part 12) rather than left as a
|
||||
comment, so it cannot be forgotten or quietly tuned away, and it wants a card of
|
||||
its own.
|
||||
|
||||
## 7. FOUND AND NOT FIXED: `migrate_unit_keys()` has the same hole, and it is a LATCH
|
||||
|
||||
Found while fixing §2's instance. It is the same defect one module over and it
|
||||
costs a **disarmed safety guard** rather than a lost history.
|
||||
|
||||
`Controller.__init__` calls `migrate_unit_keys(store, UNIT_A)` — a hardcoded
|
||||
constant where the maintenance migration now passes the roster's own first name.
|
||||
It **has** to run before `build_roster()`, because each `Inverter` restores its
|
||||
sign latch in its constructor, so there is no roster to name yet and
|
||||
`_verify_moves()` is passed `roster=None`. On a **declared** roster a pre-DEV-02
|
||||
`sign_tripped: true` therefore lands under `unit/inverter-a/sign_tripped`, which
|
||||
no unit on that site reads.
|
||||
|
||||
**And the guard that exists for exactly this is defeated by the key the defect
|
||||
wrote.** `_grade_store_migration()` re-arms the latch when the flat key says
|
||||
tripped and *nothing namespaced is latched*. The misdirected write **is**
|
||||
namespaced and **is** latched, so `namespaced_latched` is `True`, the guard
|
||||
returns, and no inverter on the roster comes up tripped — on an install whose
|
||||
`/data/state.json` still reads `sign_tripped: true`. That is DEV-02's own
|
||||
sentence for the worst case: the state file says protected, the banner is green,
|
||||
and the controller resumes commanding into the fault that tripped it.
|
||||
|
||||
Measured, on the same `["garage", "shed"]` roster:
|
||||
|
||||
```
|
||||
pre-DEV-02 flat latch + declared roster ['garage', 'shed'] ->
|
||||
migrated 2 flat key(s): unit/inverter-a/sign_reason, unit/inverter-a/sign_tripped
|
||||
latch keys in the store: ['sign_tripped', 'site_sign_tripped', 'unit/inverter-a/sign_tripped']
|
||||
roster came up tripped: [('garage', False), ('shed', False)]
|
||||
the same store on the FLAT config -> [('inverter-a', True)]
|
||||
```
|
||||
|
||||
The last line is the counterfactual: on the flat shape, where `UNIT_A` really is
|
||||
the roster's only name, the same store migrates and comes up latched. So this is
|
||||
a defect of the **declared roster**, not of the migration as such.
|
||||
|
||||
**Why it is not fixed here.** The remedy is to name the migration's target from
|
||||
the config before any `Inverter` exists, which means factoring `build_roster()`'s
|
||||
naming rule out of `build_roster()` so there is still only **one** spelling of
|
||||
it — `inverter.py` and SAFETY-02's latch semantics, with its own mutation battery
|
||||
over `test_inverter.py` and `test_watchdog.py`. MAINT-05 moves the maintenance
|
||||
history and nothing about the sign latch, and a silent expansion into a safety
|
||||
latch is how a rejected PR becomes a broken one.
|
||||
|
||||
It is pinned as a running check (`test_maintenance.py` part 13) rather than left
|
||||
as a comment. ⚠️ **Its assertions state the WRONG behaviour on purpose** — read
|
||||
them as the specification of a defect; the card that fixes it should expect them
|
||||
to go red and should replace them.
|
||||
|
||||
### And its MARKER GATE had the round-3 hole too — found here, closed here
|
||||
|
||||
Separate from the namespace hole above, and **fixed** rather than recorded,
|
||||
because closing it cost one test fixture and no source change.
|
||||
`migrate_unit_keys()` gates `schema_version` on `rep.ok` exactly as
|
||||
`migrate_maint_keys()` gates its own marker, and every check that reached that
|
||||
gate ran on a store where **nothing** was namespaced yet — so `rep.kept` was
|
||||
empty in all of them and
|
||||
|
||||
```
|
||||
if rep.ok: -> if rep.ok or rep.kept:
|
||||
```
|
||||
|
||||
**survived all 19 files**. What it does is stamp the schema marker on a
|
||||
migration that DROPPED THE LATCH: the guard is off, the state file still reads
|
||||
`sign_tripped: true`, and because the store now says the migration finished, the
|
||||
next start skips the one thing that would have re-armed it. DEV-02's own worst
|
||||
case, filed under *done*.
|
||||
|
||||
`test_inverter.py` part 10 now drops the `sign_tripped` write **beside an
|
||||
already-namespaced `sign_reason`** — `lost` non-empty *and* `kept` non-empty,
|
||||
which is the one shape none of the existing fixtures had — and asserts the
|
||||
marker is withheld, with the accepted-baseline counterfactual beside it (habit
|
||||
7). The shipped gate was correct throughout; what changed is that a check can
|
||||
now see it.
|
||||
@@ -0,0 +1,474 @@
|
||||
# SAFETY-30 — what the sign watchdog compares once there is more than one inverter, and the numbers it compares with
|
||||
|
||||
**Status: DECIDED 2026-09-04.** The one comparison becomes **two**, asked of the
|
||||
evidence that can answer each: **each unit's standing command against that
|
||||
unit's own measured power** (register 0x0518, per-instance since [[DEV-02]]),
|
||||
and **the sum of the standing commands against the meter**. At a roster of one
|
||||
nothing changes at all — the two questions are the same sentence there, and the
|
||||
detector that ships is the only one armed.
|
||||
|
||||
This document records the argument for that split, the campaign the four numbers
|
||||
were read off, **a number that was carried and a number that refused to be**, and
|
||||
the mutation ledger. Filed with SAFETY-30, card `6a9a1828e844f22fabf7fe9c`.
|
||||
|
||||
---
|
||||
|
||||
## 0. The half that was already built, and the half this card is
|
||||
|
||||
[[DEV-02]] shipped the **per-instance** half and nothing here re-tests it: each
|
||||
`Inverter` owns its own `SignWatchdog`, the latch is namespaced under
|
||||
`unit/<name>/sign_tripped`, the flat pre-DEV-02 pair is maintained as a rollback
|
||||
view, and a trip on B no longer latches A. `test_inverter.py` part 3 grades that.
|
||||
|
||||
What was left is **the comparison itself**, and it was one line:
|
||||
|
||||
```python
|
||||
inv.sign_wd.evaluate(stood, self.grid, self.following, now) # every unit
|
||||
```
|
||||
|
||||
`stood` is the command **this controller put on THIS actuator**. `self.grid` is
|
||||
what the **whole site** is exchanging with the network. At one inverter those are
|
||||
two views of one thing — §6.2's identity — which is what makes the check sound
|
||||
and what earned its record. At two they are not, and it fails in **both**
|
||||
directions:
|
||||
|
||||
| | what happens | why no threshold fixes it |
|
||||
|---|---|---|
|
||||
| **false trip** | A commanded −1500 W while the meter reads +1500 W, because B is discharging 3000 W exactly as told | the meter is answering for a unit A's command says nothing about |
|
||||
| **missed fault** | B commanded +1500 W and **measured** at −1500 W, beside A at +1500 W — the meter sits where a healthy site leaves it | the summation **destroys** the evidence |
|
||||
|
||||
NOTES.md calls SAFETY-02 the highest-value check in the safety table: 93 %
|
||||
agreement while healthy against 4 % during runaway, four observed episodes, zero
|
||||
false positives. **That record was earned at N=1 on the site comparison.** The
|
||||
first row above spends it; the second row is the guard being absent when it
|
||||
matters.
|
||||
|
||||
## 1. The two questions, and the two remedies
|
||||
|
||||
> **PER UNIT** — this unit's standing command against **its own** measured power.
|
||||
> Conclusion: *the actuator I am driving is not doing what I told it.* Evidence
|
||||
> about one device, so the remedy is that device: the `failsafe` SET, which
|
||||
> `arbiter.CLAIM_SCOPE` has classified `SCOPE_UNIT` since it was written.
|
||||
>
|
||||
> **SITE** — the **sum** of the standing commands against the meter. Conclusion:
|
||||
> *the site as a whole is driving the wrong way* — an inverted gain, an
|
||||
> integrator wound past the rail, a strategy on the wrong side of the meter.
|
||||
> That is the 2026-08-20 fault day, it is a property of the **connection**, and
|
||||
> the remedy is a new SITE SET, `sign_site`, that stops every inverter.
|
||||
|
||||
### Why `failsafe` stays per-unit and `sign_site` is new
|
||||
|
||||
`CLAIM_SCOPE`'s entry for `failsafe` used to read *"the evidence is site-wide and
|
||||
the remedy is not"* — a site measurement attributed to one actuator on the
|
||||
strength of the N=1 identity. After this card the first half of that sentence is
|
||||
simply true: the evidence **is** per-unit. The site-wide half did not disappear;
|
||||
it moved to a claim that is site-scoped for the reason `circulation` is, one
|
||||
entry above it: **the offending number is the site target, which no single
|
||||
inverter owns.** Parking one unit on it would leave the rest of the roster
|
||||
pushing the same way with the guard satisfied.
|
||||
|
||||
### At N=1, exactly one detector is armed
|
||||
|
||||
`Controller._arm_sign_watchdogs()` is the only place the roster decides anything
|
||||
here, and it is a pure function of `len(self.inverters)`:
|
||||
|
||||
* **one inverter** — the unit detector is armed against **the meter**, at the
|
||||
shipped `sign_disagree_w` / `sign_disagree_s`. The site detector is
|
||||
**constructed and never evaluated**. Same comparison, same thresholds, same
|
||||
reason string byte for byte, same namespaced keys and flat mirror, same
|
||||
`failsafe` claim, same banner, same single status row. `test_watchdog.py`
|
||||
part 7 asserts each of those, including that the site detector's window was
|
||||
never so much as opened.
|
||||
* **two or more** — each unit against its own 0x0518 power under the per-unit
|
||||
pair, and the site detector against the meter under the site pair.
|
||||
|
||||
Arming both at N=1 would be two latches and two banners for one fault, and a
|
||||
false-positive record measured on **one** comparison spent twice.
|
||||
|
||||
## 2. What this is NOT — the two neighbours, named
|
||||
|
||||
Two guards that overlap without saying so is how a false-alarm generator gets
|
||||
built, so both are written down.
|
||||
|
||||
### It is not [[SAFETY-31]]
|
||||
|
||||
| | **SAFETY-31 — `circulation.py`** | **SAFETY-30 — the per-unit half** |
|
||||
|---|---|---|
|
||||
| compares | the units **against each other**: `Σ\|Bᵢ\| − \|ΣBᵢ\|` over measured power | each unit against **its own command** |
|
||||
| catches | two inverters pushing **through** each other; nets to zero at the meter | a unit **not doing what it was told**; that unit is faulty or wedged |
|
||||
| attributes | nothing — the quantity is defined over the roster and is identically zero for one unit | **the unit**, by name, and parks it |
|
||||
| scope | SITE claim, flat latch | UNIT claim, namespaced latch |
|
||||
|
||||
They genuinely overlap in **one** scenario — a unit reversing while its sibling
|
||||
pulls the other way — and `test_watchdog.py` part 4 asserts exactly that, on the
|
||||
same fixture, with both readings printed: circulating power is over its threshold
|
||||
**and** SAFETY-30 names B. Neither is the other with a different threshold. Take
|
||||
two units faithfully executing an allocation with two signs: circulating power is
|
||||
the whole loop and every per-unit sign check reads perfect agreement. Take one
|
||||
unit doing the opposite of its share while its sibling covers: this reads the
|
||||
whole disagreement and circulating power can be zero.
|
||||
|
||||
### It is not the saturation freeze
|
||||
|
||||
`compute()`'s anti-windup test is `|prev_w − actual_w| > saturation_w` (500 W). It
|
||||
concludes *the inverter cannot follow*, it fires on a merely **saturated** unit as
|
||||
readily as on a reversed one, it **stops the integrator winding** — an ordinary
|
||||
control action taken every day — and it neither latches nor parks anything.
|
||||
|
||||
This asks for **opposition**: a sign, on both sides of a threshold, held
|
||||
continuously. A saturated-but-obedient unit cannot produce it. And the two meet
|
||||
at a number rather than overlapping in a band nobody drew — see §3.
|
||||
|
||||
## 3. The numbers, and where they come from
|
||||
|
||||
Read off `admin/goodwe`'s `sim/` two-master rig (TEST-19), used **read-only** and
|
||||
run container-free. Real and imported, never transcribed: the control law
|
||||
(`control.compute`, `Tuning`), the allocator (`arbiter.allocate_record` →
|
||||
`allocator.plan`), the sign predicate (`watchdog.disagrees`), the wire
|
||||
(`frame_check.setpoint_atomic`, the firmware's own encoder), the plant
|
||||
(`plantsim.Plant`), and the per-unit reading, taken from **holding register
|
||||
0x0518** — the register the live `batt_entity` binds.
|
||||
|
||||
**1890 closed-loop runs in which NOTHING is faulty** — every unit executes the
|
||||
share the allocator gave it — over **6 gains × 5 slews**, the whole range
|
||||
`config.yaml` accepts for `gain` `float(0.05,1.0)` and `slew_w` `int(50,5000)`,
|
||||
across both families of stimulus that can produce legitimate opposition:
|
||||
|
||||
* **1050 load reversals** — 7 sizes (±300 W … ±4000 W) × 5 write staggers, the
|
||||
serialised write path landing unit B's number up to four cycles after A's;
|
||||
* **840 flapping loads** — 7 periods (10 s … 600 s) × 4 amplitudes.
|
||||
|
||||
Every run is executed **twice**: once at a roster of two and once at a roster of
|
||||
one on the same stimulus. **The N=1 arm is the control**, and it is the reason
|
||||
this document can separate *"a property of the check that shipped"* from *"a
|
||||
property of the second inverter"* instead of asserting one and hoping.
|
||||
|
||||
Supervised caps are the shipped `max_w` (2000 W per unit), so the site rail is
|
||||
2000 W at N=1 and 4000 W at N=2 — `Controller.site_max_w`, the roster sum.
|
||||
|
||||
### Reproducing it
|
||||
|
||||
The harness is **not committed here**, for the reason SAFETY-31's was not: it
|
||||
imports `plantsim` and `frame_check`, which live in the other repository and are
|
||||
not present in CI. What it does is small enough to restate: build two
|
||||
`plantsim.Inverter`s from `INVERTER_A` / `INVERTER_B`, close the loop with the
|
||||
add-on's own `compute()` and `arbiter.allocate_record()`, put each share on its
|
||||
own wire through `Inverter.command()`, advance `Site.settle()` one control cycle,
|
||||
and record `(standing command, inv.reg(0x0518))` per unit and
|
||||
`(Σ standing, site.grid)` for the site. Then, for each candidate threshold, the
|
||||
**longest run of consecutive cycles** on which the shipped `disagrees()` is true —
|
||||
not a count of true samples, because the watchdog's window is cleared by any
|
||||
disagreeing sample. Point it at a checkout with `GOODWE_ADDON_REPO`.
|
||||
⚠️ MUTATION.md's note applies: those harnesses write `__pycache__` into **both**
|
||||
trees.
|
||||
|
||||
### A. PER-UNIT — a unit's standing command vs its own 0x0518 power, N=2
|
||||
|
||||
| threshold | worst continuous, reversals | worst continuous, flapping | runs crossing (of 1890) |
|
||||
|---:|---:|---:|---:|
|
||||
| 50 W | 25.0 s | 20.0 s | 962 |
|
||||
| 100 W | 20.0 s | 15.0 s | 511 |
|
||||
| 150 W | 15.0 s | 15.0 s | 379 |
|
||||
| 200 W | 10.0 s | 15.0 s | 258 |
|
||||
| **250 W** | **10.0 s** | **10.0 s** | **194** |
|
||||
| 300 W | 10.0 s | 10.0 s | 124 |
|
||||
| 500 W | 5.0 s | 5.0 s | 37 |
|
||||
| 700 W | 5.0 s | 5.0 s | 16 |
|
||||
| 1000 W | 0.0 s | 0.0 s | 0 |
|
||||
|
||||
Largest opposed magnitude anywhere in the 1890 runs: **875 W**.
|
||||
|
||||
**The curve is flat, and that is the finding that decided the shape of this
|
||||
pair.** Unlike the site comparison — where the meter is driven by the LOAD and a
|
||||
flapping load can hold it opposed for minutes — a unit's own power **chases its
|
||||
own command** through a bounded ramp and a first-order lag, so the opposition can
|
||||
only last as long as the crossing does. Dropping the threshold from 300 W to
|
||||
50 W buys 15 s of extra transient and nothing else. **So the work is done by the
|
||||
window, and the threshold is put where the control law already draws its line.**
|
||||
|
||||
#### `unit_sign_disagree_w: 250` — schema `int(50,5000)`
|
||||
|
||||
`saturation_w / 2`. The check gates on **both** sides being over `min_w`, and the
|
||||
two are **opposed**, so the smallest command-versus-power gap it can ever see is
|
||||
`2 × min_w`. At 250 W that is exactly the 500 W at which `compute()`'s own
|
||||
anti-windup test already concludes the inverter is not following. **This watchdog
|
||||
therefore cannot fire on a divergence the shipped control law itself calls
|
||||
ordinary tracking**, and the two guards meet at a number.
|
||||
|
||||
Rejected: a threshold above the observed 875 W maximum, which would gate nothing
|
||||
legitimate in — and would also be blind to a unit reversing a 900 W share.
|
||||
|
||||
#### `unit_sign_disagree_s: 85` — schema `int(30,1800)`
|
||||
|
||||
Three bounds, and the value clears all three.
|
||||
|
||||
* **lower, from the rig — 10.0 s.** Two control cycles, the worst continuous
|
||||
legitimate opposition above 250 W across all 1890 runs. It is a reversing site
|
||||
whose second write lands a cycle after the first, both units then slewing
|
||||
through zero behind a 10 s lag. Nothing is wrong.
|
||||
* **lower, from the firmware — 30 s (`inverter.LINK_STALE_S`).** A unit not
|
||||
executing its share for less than the firmware's own veto window is a *link*
|
||||
fault the add-on already answers by dropping the unit from the split. Firing
|
||||
inside that window would raise a second, louder alarm about a state already
|
||||
being handled — the SAFETY-15/SAFETY-19 failure exactly.
|
||||
* **upper, from SAFETY-02 itself — 180 s, the site hold.** A unit that is not
|
||||
doing what it was told must not be parked *later* than the site would be
|
||||
parked for the same watts, and this conclusion needs nothing to net out: it is
|
||||
complete on the first cycle it appears.
|
||||
|
||||
**85 s** is seventeen control cycles: **8.5× the worst legitimate episode**,
|
||||
**2.8× the firmware veto**, and **under half** the site hold. Deliberately not
|
||||
60, 75, 90, 120 or 180.
|
||||
|
||||
### B / C. SITE — Σ standing commands vs the meter, at BOTH rosters
|
||||
|
||||
**Load-reversal family** (1050 runs each), worst continuous legitimate opposition:
|
||||
|
||||
| threshold | **N=2** | **N=1 (control)** | ratio |
|
||||
|---:|---:|---:|---:|
|
||||
| 100 W | 335.0 s | 175.0 s | 1.91× |
|
||||
| 200 W | 260.0 s | 120.0 s | 2.17× |
|
||||
| **300 W** | **215.0 s** | **110.0 s** | **1.95×** |
|
||||
| 500 W | 155.0 s | 90.0 s | 1.72× |
|
||||
| 700 W | 130.0 s | 70.0 s | 1.86× |
|
||||
| 1000 W | 85.0 s | 35.0 s | 2.43× |
|
||||
|
||||
**The second inverter roughly DOUBLES the worst legitimate crossing, and at the
|
||||
shipped 300 W threshold it takes it from 110 s — comfortably inside the 180 s
|
||||
hold — to 215 s, which is outside it.**
|
||||
|
||||
The mechanism is not mysterious and is worth stating because it predicts the
|
||||
ratio: the transient the 180 s hold exists to reject is the loop crossing zero
|
||||
after a load reversal, and the command has to travel the whole **site rail** at
|
||||
`slew_w` per cycle. At N≥2 that rail is `Controller.site_max_w`, the roster sum,
|
||||
while `slew_w` is unchanged. The worst case is the corner of the config space
|
||||
where that takes longest — `gain: 0.05`, `slew_w: 50`, both **schema floors** —
|
||||
against a ±2200 W load reversal, which is an oven and a heat pump.
|
||||
|
||||
#### `site_sign_disagree_w: 300` — CARRIED, and here is the justification
|
||||
|
||||
The argument behind 300 W is about **noise**: *"near zero the sign is noise, and
|
||||
near zero is where a healthy loop LIVES"* — the deadband holds the command still
|
||||
while the meter wanders either side of `target_grid_w`. `deadband_w` is 15 W and
|
||||
there is one P1 whatever is behind it. **Nothing in that argument depends on the
|
||||
roster**, and the campaign agrees: the fraction of samples gated in at 300 W is
|
||||
within a few percent at both rosters. Carried, with a measurement behind the
|
||||
carry rather than an assumption.
|
||||
|
||||
#### `site_sign_disagree_s: 325` — NOT carried, and that is the point of the card
|
||||
|
||||
180 s is **inside** the 215 s the two-inverter campaign measures, at a
|
||||
configuration the schema accepts. Carrying it would have shipped a false trip on
|
||||
the check with the best record in the safety table — which is the exact failure
|
||||
this card was opened to prevent, arriving from the other direction.
|
||||
|
||||
**325 s** is 1.51× the measured worst. It is well inside the **900 s** quarter
|
||||
that bills the capacity tariff, and it is inside **every** episode the fault day
|
||||
contains: 2026-08-20's four clusters run 16, 30, 77 and 77 minutes, and its
|
||||
opposed runs reach 1750 s. What it costs is stated rather than hidden — about two
|
||||
and a half extra minutes of wrong-direction **site** power before the stop —
|
||||
and it is bought to remove a false trip a legal configuration produces.
|
||||
Deliberately not 300 or 360.
|
||||
|
||||
**Rejected alternative:** keep 180 s and raise the site threshold to 1000 W,
|
||||
where the worst is 85 s. It gives a better margin and a faster stop, and it is
|
||||
wrong: it would be raising a **noise** gate to reject a **transient**, which is
|
||||
what the window is for, and it would leave the site check blind to a 900 W
|
||||
whole-site reversal at a 4 kW site.
|
||||
|
||||
### A limitation this campaign found, which SAFETY-30 does not introduce and does not fix
|
||||
|
||||
The **flapping-load** family behaves completely differently for the SITE
|
||||
comparison, and the control arm is what makes it interpretable:
|
||||
|
||||
| threshold | **N=2** | **N=1 (control)** |
|
||||
|---:|---:|---:|
|
||||
| 300 W | 980.0 s | 1000.0 s |
|
||||
| 700 W | 975.0 s | 1000.0 s |
|
||||
| 1000 W | 950.0 s | 1000.0 s |
|
||||
|
||||
A square wave whose half period is about one control cycle opposes the command on
|
||||
**every** cycle: the command chases the previous half-cycle's meter while the
|
||||
meter has already reversed. **No window inside the billing quarter survives it and
|
||||
no threshold up to 1000 W does either — at EITHER roster.** The N=1 column is
|
||||
this document's whole reason for existing: this is a property of comparing a
|
||||
lagged command against a meter, and it has nothing to do with the second
|
||||
inverter.
|
||||
|
||||
It is not acted on here, in order of weight: it is **identical at the roster this
|
||||
add-on ships**, so acting on it would be changing a live safety path on evidence
|
||||
that has nothing to do with this card; a ~6 kW square wave at 0.1 Hz sustained
|
||||
for a quarter of an hour is not a house (the captured healthy day's longest
|
||||
opposed run is **30 s**); and the fix is not a number — it wants the detector to
|
||||
notice that the disagreement is **alternating**, which is a different check.
|
||||
**It is a card, and this section is its evidence.**
|
||||
|
||||
### D. The fault arm — because a survey of healthy data is not a derivation
|
||||
|
||||
210 runs with inverter B executing the **negation** of its share throughout,
|
||||
sibling faithful, meter left to net:
|
||||
|
||||
| threshold | longest run the per-unit check detects | runs the SITE check also sees |
|
||||
|---:|---:|---:|
|
||||
| 250 W | 890.0 s | 210 / 210 |
|
||||
| 300 W | 890.0 s | 180 / 210 |
|
||||
| 700 W | 885.0 s | 112 / 210 |
|
||||
| 1000 W | 885.0 s | 60 / 210 |
|
||||
| 1500 W | 880.0 s | 45 / 210 |
|
||||
| 2000 W | 0.0 s | 39 / 210 |
|
||||
|
||||
At the shipped 250 W the fault is detected continuously for the whole run in
|
||||
every one of the 210 — an 85 s hold has ten times the evidence it needs. The
|
||||
right-hand column is the honest half: on a *reversing* stimulus the site
|
||||
comparison often does see something too, because the reversal is large enough to
|
||||
move the meter. **The case it cannot see is the steady one**, and that is the
|
||||
fixture `test_watchdog.py` part 4 runs: the shipped comparison is false on
|
||||
**0 of 14** cycles while the per-unit check convicts B on every one.
|
||||
|
||||
## 4. Inverter B does not exist
|
||||
|
||||
Every two-inverter figure in §3 was produced with **inverter A's ramp and lag
|
||||
copied onto B** (`plantsim.INVERTER_B`, `measured=False`); its 3000 W rating,
|
||||
where this repository's fixtures use one, is a **hypothesis marked as one**.
|
||||
[[SPIKE-04]] measures the real ones and is the revisit trigger for all four
|
||||
numbers — not a reason to move any of them now.
|
||||
|
||||
Which figures depend on it, stated so nobody has to work it out:
|
||||
|
||||
* **`unit_sign_disagree_s: 85`** — most. Its lower bound is the 10.0 s crossing,
|
||||
which is a direct function of B's ramp and lag. A slower second unit lengthens
|
||||
it; the 8.5× is what buys headroom for that.
|
||||
* **`site_sign_disagree_s: 325`** — yes, but less directly. Its 215 s is
|
||||
dominated by the **rail** and by `slew_w`, which are configuration, not
|
||||
hardware; B's dynamics move it at the margin.
|
||||
* **`unit_sign_disagree_w: 250`** — **no.** It is `saturation_w / 2`, read off
|
||||
the add-on's own control law. The rig only confirms that nothing legitimate
|
||||
sits over it for long.
|
||||
* **`site_sign_disagree_w: 300`** — **no.** It is the meter's noise floor and the
|
||||
deadband, neither of which is a property of any inverter.
|
||||
|
||||
## 5. Mutation ledger
|
||||
|
||||
Every run on a **freshly copied tree of its own, no `__pycache__`, mounted
|
||||
`:ro`** into the CI image — the structural immunity MUTATION.md records. ⚠️ The
|
||||
first battery used ONE shared directory rebuilt between mutations and reported a
|
||||
**RED baseline**; a container mounted it mid-copy and read a missing
|
||||
`config.yaml` as a failing check. That whole run was discarded: MUTATION.md's
|
||||
rule is that a run which could have been racing is not a result, and a battery
|
||||
whose baseline is not green establishes nothing. The harness now copies a
|
||||
directory per mutation and **refuses to report anything if the baseline is not
|
||||
green**.
|
||||
|
||||
Byte deltas measured, not estimated; the `+0 B` ones are marked, since a
|
||||
size-preserving edit is what TEST-15 turned into a false survivor once already.
|
||||
|
||||
| # | file | mutation | Δ | result |
|
||||
|---|---|---|---|---|
|
||||
| M1 | `main.py` | the per-unit comparison put back to `self.grid` at every roster | −30 B | **RED** — `test_watchdog.py`. This is the card |
|
||||
| M2 | `main.py` | the per-unit comparison forced to `inv.batt` at N=1 too | −31 B | **RED** — AC 8 |
|
||||
| M3 | `main.py` | the site half never evaluated | −6 B | **RED** — AC 3 |
|
||||
| **M4** | `main.py` | **the site half armed at N=1 as well** | **+0 B** | **SURVIVOR on the first battery — GAP CLOSED**, then RED. See below |
|
||||
| M5 | `main.py` | the `sign_site` claim never filed | −6 B | **RED** — `test_watchdog.py`. ⚠️ `test_peakguard.py` stayed **GREEN**, correctly: 10f's AST scan pins which sources CAN be filed and the append is still written; whether it is REACHED is a dynamic question no fixture there gets to |
|
||||
| M6 | `main.py` | the site latch not persisted to the store | −58 B | **RED** — the flat-keys and restart checks |
|
||||
| M7 | `main.py` | the operator clear leaves the site latch set | −42 B | **RED** — the clear check |
|
||||
| M8 | `watchdog.py` | `arm()` clears `disagree_since` | +35 B | **RED** — "re-armed on every one of 38 cycles still trips" |
|
||||
| M9 | `watchdog.py` | the reason hard-codes "a meter reading" again | +1 B | **RED** — `test_watchdog.py`. `test_inverter.py` stayed **GREEN**; its part-3 row reads the noun off `sign_wd.against` rather than out of the reason string, so the two checks bite in different places |
|
||||
| M10 | `watchdog.py` | `unit_sign_disagree_w` 250 → 300 | **+0 B** | **RED** — the `saturation_w / 2` pin and the CFG-03 pin |
|
||||
| M11 | `watchdog.py` | `site_sign_disagree_s` 325 → 180, i.e. **the number carried** | **+0 B** | **RED** — the measured-215 s check and the CFG-03 pin |
|
||||
| M12 | `arbiter.py` | `sign_site` scoped `SCOPE_UNIT` | **+0 B** | **RED** — `test_arbiter.py` **and** `test_peakguard.py` |
|
||||
| M13 | `validate.py` | the `unit_sign_disagree_w` rule removed | −126 B | **RED** — `test_validate.py` |
|
||||
| **M14** | `main.py` | **`arm()` handed `self.sign_cfg` at EVERY roster** — the WIRING, not the values | −31 B | **SURVIVOR at review — GAP CLOSED**, then RED. See below |
|
||||
| M15 | `main.py` | per-unit `arm()` given the right `min_w` and the SHIPPED hold — a HOLD-ONLY mis-wire | +78 B | **RED** — the same wiring pin |
|
||||
| M16 | `main.py` | per-unit `arm()` given the right `min_w` and the SITE hold — hold-only again, and behaviour-preserving | +83 B | **RED** — the wiring pin, and the ONLY red in `test_watchdog.py` |
|
||||
|
||||
### M4 is recorded as a survivor because it was one
|
||||
|
||||
The check it should have gone red on read:
|
||||
|
||||
```python
|
||||
not _c1s.site_sign_wd.tripped and _c1s.site_sign_wd.disagree_since is None
|
||||
```
|
||||
|
||||
Arming the site detector at a roster of one left that **green**, and the reason
|
||||
is worth reading because the check looked airtight. In the N=1 fixture the unit
|
||||
detector trips first at its 1 s hold and parks the inverter; the site's standing
|
||||
command is then **0 W**, so the site predicate is false, its window is never
|
||||
opened, and `disagree_since is None` is true *whether or not the detector was
|
||||
evaluated at all*. **The assertion ran, the sentence was true, and the data
|
||||
could not reach the failure it named** — MUTATION.md's third failure mode,
|
||||
inside the check written to prevent it.
|
||||
|
||||
Replaced with a **call counter installed on the object** before the run: twelve
|
||||
cycles, zero calls, printed. A counter can only be zero for one reason. The
|
||||
mutation was re-run against it and is red; the run that found it was discarded
|
||||
along with its tree, so this is a result and not an artefact.
|
||||
|
||||
### M14: the VALUES were pinned and the WIRING was not
|
||||
|
||||
M10 and M11 mutate the numbers in `watchdog.SIGN_OPTION_DEFAULTS` and both are
|
||||
red through the config pins. Neither of them touches the line that DELIVERS
|
||||
those numbers to a detector:
|
||||
|
||||
```python
|
||||
inv.sign_wd.arm(self.sign_cfg if one else self.unit_sign_cfg,
|
||||
AGAINST_METER if one else AGAINST_OWN_POWER)
|
||||
```
|
||||
|
||||
Drop the conditional — `arm(self.sign_cfg, ...)` — and every unit is armed with
|
||||
SAFETY-02's meter-facing pair instead of the re-derived per-unit one. At review
|
||||
that left **all 19 files green**. `grep -rn "sign_wd.cfg" test_*.py` found
|
||||
exactly one threshold assertion, and it is §7's N=1 arm — `(300.0, 1.0)` —
|
||||
which the mutation PRESERVES. Nothing anywhere read `inv.sign_wd.cfg` at a
|
||||
roster of two.
|
||||
|
||||
The behavioural checks in part 3 cannot close it and it is worth saying why: B
|
||||
is reversed at ~2000 W and every hold in that fixture is short, so B trips under
|
||||
either pair. **A fault big enough and long enough to trip under both thresholds
|
||||
is evidence about neither.**
|
||||
|
||||
What the survivor costs in the field is the whole product of §3: at
|
||||
`config.yaml`'s own defaults the per-unit check would run at `sign_disagree_s`
|
||||
**180 s instead of 85 s** — 2.1× slower to park a reversed inverter — and its
|
||||
gate would move from 250 W to 300 W, so a unit reversing a share between the two
|
||||
becomes invisible, while `SIGN_OPTION_DEFAULTS`, `config.yaml` and §3 all go on
|
||||
describing a pair the running code does not use. With CI green.
|
||||
|
||||
**Closed by a wiring pin in `test_watchdog.py` part 3**, on the real
|
||||
two-inverter Controller: every `inv.sign_wd.cfg` equals the per-unit pair,
|
||||
`site_sign_wd.cfg` equals the site pair, and each detector's `against` is its
|
||||
own instrument — all graded **against literals**, since `== self.unit_sign_cfg`
|
||||
cannot tell *the per-unit pair* from *whatever this Controller was handed*.
|
||||
|
||||
⚠️ **And the fixture had to be changed for that pin to mean anything.**
|
||||
`_sign_site` set `unit_sign_disagree_s: 1` **and** `site_sign_disagree_s: 1`
|
||||
**and** `sign_disagree_s: 1`, with two of the three magnitude gates at 300 W. A
|
||||
bare equality there discriminates on `min_w` alone: a mis-wiring that delivered
|
||||
the right magnitude with the wrong hold would compare EQUAL to the pair it was
|
||||
supposed to have. That is this document's own §5 lesson and MUTATION.md's third
|
||||
failure mode — a check comparing two things that happen to be equal cannot see
|
||||
the difference it names — reappearing inside the fix for it. The three pairs are
|
||||
now pairwise distinct **in both coordinates** (250 W / 1 s, 320 W / 2 s,
|
||||
300 W / 3 s), a PRECONDITION check asserts that distinctness so a later edit
|
||||
collapsing them goes red rather than quietly vacuous, and both pairs are
|
||||
**printed**. M15 and M16 exist to show the hold half actually bites: right
|
||||
magnitude, wrong hold, red both times — and M16, whose wrong hold still trips
|
||||
inside the drive, is red on the wiring pin and on **nothing else** in that file.
|
||||
|
||||
## 6. What this card does NOT close
|
||||
|
||||
* **The flapping-load blind spot in the SITE comparison.** §3, at length. Present
|
||||
identically at the shipped roster of one; wants an alternation test, not a
|
||||
number; a card of its own.
|
||||
* **A unit misbehaving while it is NOT loop-driven.** Gate 1 (`following`) is
|
||||
kept for the per-unit comparison, deliberately: the whole no-false-positive
|
||||
argument is built on it, and the saturation freeze already grades that window.
|
||||
So between the start of a maintenance cycle and its end, a unit reversing
|
||||
against its own command is the freeze's to notice. Widening it is a card with a
|
||||
rig campaign behind it, not an edit.
|
||||
* **A sign inversion downstream of this add-on** — in the firmware, on the wire,
|
||||
or in a future driver. Unchanged: our view stays self-consistent and both
|
||||
comparisons stay silent. That is the witness's problem and it always was.
|
||||
* **A false-alarm interaction with SAFETY-31 that nobody has to think about.**
|
||||
They overlap in one scenario and both fire in it. That is correct — they
|
||||
conclude different things — but an operator will see two alarms for one event.
|
||||
Whether the banner should say so in one sentence is a UI card.
|
||||
@@ -78,9 +78,20 @@ inverters:
|
||||
setpoint_entity: number.goodwe_b_setpoint_w
|
||||
soc_entity: sensor.goodwe_b_soc
|
||||
batt_entity: sensor.goodwe_b_battery_power
|
||||
max_w: 3000
|
||||
max_w: 4600
|
||||
```
|
||||
|
||||
⚠️ **The 4600 W is inverter B's *datasheet* figure, not a measured one.** B is a
|
||||
GoodWe GW5048D-ES (serial `55048ESU22AW0992`, identified 2026-09-04) whose
|
||||
datasheet gives max charging and discharging power as 4600 W; with nothing
|
||||
connected to its PV inputs the battery path is the ceiling, not the 5000 VA AC
|
||||
nameplate. The datasheet prints that number under *Battery Input Data*, so it
|
||||
may be a DC figure, while `max_w` is graded against register `0x0518` — the
|
||||
inverter's own **AC** power. If it is DC the AC-side ceiling is nearer 4324 W.
|
||||
`max_w: 4600` is still the right thing to configure, because the freeze rail is
|
||||
`min(max_w, dev_max)` and the device range read off the unit is what binds.
|
||||
`goodwe/NOTES.md` §1.1b records both readings and picks neither.
|
||||
|
||||
| per-entry key | required | meaning |
|
||||
|---|---|---|
|
||||
| `name` | yes | Short identifier. It namespaces this unit's SAFETY-02 latch, heartbeat and write bookkeeping in the add-on's state file, so **two units may not share one** |
|
||||
@@ -363,6 +374,10 @@ behind it would trip the firmware watchdog on a system that is working fine.
|
||||
| `auto_start` | false | Start controlling on boot (only after commissioning) |
|
||||
| `sign_disagree_w` | 300 | Both the command and the meter must exceed this before a sign difference counts. Must stay **below `max_w`** or the watchdog can never fire, and the add-on refuses to start |
|
||||
| `sign_disagree_s` | 180 | How long they must stay opposed, continuously, before the failsafe trips |
|
||||
| `unit_sign_disagree_w` | 250 | **Two or more inverters only.** Both a unit's own share and its own measured power must exceed this before their sign difference counts. It is `saturation_w / 2`, so the smallest divergence it can see is exactly the gap at which the loop already calls the inverter "not following". Must stay **below `max_w`** or it can never fire, and the add-on refuses to start |
|
||||
| `unit_sign_disagree_s` | 85 | **Two or more inverters only.** How long one unit's command and its own power must stay opposed before that unit is parked |
|
||||
| `site_sign_disagree_w` | 300 | **Two or more inverters only.** Threshold for the site-wide check - the sum of the commands against the meter. The same 300 W as `sign_disagree_w`, for the same reason: near zero the sign is noise |
|
||||
| `site_sign_disagree_s` | 325 | **Two or more inverters only.** How long the site's total command and the meter must stay opposed before every inverter is parked. Longer than `sign_disagree_s` because the command has to cross zero over a rail that is the sum of the roster, at a `slew_w` that is not - measured at 110 s with one inverter and 215 s with two |
|
||||
|
||||
#### The sign-disagreement failsafe
|
||||
|
||||
@@ -374,6 +389,43 @@ there. The banner reads `FAILSAFE`, the commissioning list says which two
|
||||
numbers disagreed and for how long, and the `Controller status` entity reports
|
||||
`failsafe`.
|
||||
|
||||
#### ⚠️ At two or more inverters this is TWO checks, not one (SAFETY-30)
|
||||
|
||||
The paragraph above describes what a **one-inverter** install does, and it is
|
||||
unchanged: there is one meter, one actuator, and comparing the command against
|
||||
the meter is comparing a thing with a view of itself.
|
||||
|
||||
With a second inverter that stops being true. The meter answers for **both**
|
||||
units, so a command put on one of them can be opposed to it with nothing wrong
|
||||
(inverter A charging while inverter B discharges more), and - the worse
|
||||
direction - a unit genuinely driving the wrong way can be **hidden**, because its
|
||||
sibling's watts arrive at the meter and the sum looks healthy. So the check
|
||||
splits in two, and they are different faults:
|
||||
|
||||
- **Per inverter** — that unit's own share against **its own measured power**
|
||||
(the `batt_entity` reading, register 0x0518). This catches *"this inverter is
|
||||
not doing what it was told"*. Only that inverter is parked; the site keeps
|
||||
running on the one that works. Thresholds: `unit_sign_disagree_w` /
|
||||
`unit_sign_disagree_s`.
|
||||
- **Site-wide** — the **sum** of what every inverter has standing, against the
|
||||
meter. This catches *"the site as a whole is pushing the wrong way"*, which no
|
||||
per-inverter check can see because every unit may be faithfully executing its
|
||||
share of a number that is itself wrong. **Every** inverter is parked and the
|
||||
banner names the site rather than an inverter. Thresholds:
|
||||
`site_sign_disagree_w` / `site_sign_disagree_s`, latched under flat
|
||||
`site_sign_tripped` in `/data/state.json`.
|
||||
|
||||
Both latch, both are cleared by the same *stop, then start*, and both survive a
|
||||
restart. **On a one-inverter install neither pair does anything at all** - the
|
||||
two questions are the same question there, and only the check described above is
|
||||
armed.
|
||||
|
||||
This is **not** the circulating-power alarm further down: that one compares the
|
||||
inverters *against each other* and catches them pushing power through each other,
|
||||
which nets to zero at the meter and which no command is evidence about. It is
|
||||
also not the saturation freeze, which is a *magnitude* test that shapes the loop
|
||||
rather than a *direction* test that parks an inverter.
|
||||
|
||||
**It does not clear itself, and restarting the add-on does not clear it either.**
|
||||
Pressing *Start / stop control* twice — stop, then start — is the only thing that
|
||||
does. That is deliberate on both counts:
|
||||
|
||||
@@ -135,11 +135,19 @@ manufactures them from a **fixture**: the check runs, the assertion is
|
||||
evaluated, the sentence above it is true — and the numbers it compares are
|
||||
arranged so that the failure it describes could not have changed the answer.
|
||||
|
||||
It is not hypothetical and it is not rare. Six instances in two weeks; three
|
||||
It is not hypothetical and it is not rare. EIGHT instances in two weeks; four
|
||||
were found by review, two - CFG-04's fixture pair - by an author's own mutation
|
||||
battery, which is the cheaper place, and the sixth by review again, in the one
|
||||
battery, which is the cheaper place, one by review again, in the one
|
||||
place nobody had thought to point the rule at: not a check in the suite, but a
|
||||
COMMITTED EVIDENCE ARTIFACT four documents cite.
|
||||
COMMITTED EVIDENCE ARTIFACT four documents cite - and the eighth INSIDE THE FIX
|
||||
WRITTEN TO CLOSE THE SEVENTH.
|
||||
|
||||
⚠️ **AND IT HAS NOW APPEARED IN SIX CONSECUTIVE CARDS.** The seventh instance,
|
||||
MAINT-05's, is the one that says why: the defect is not carelessness about
|
||||
fixtures, it is that **a check and the thing it checks were built from the same
|
||||
constant**. Ask of every difference-claim not "is this assertion true" but
|
||||
"where did each side of this comparison come from" - and if the answer is the
|
||||
same place twice, the check is decoration.
|
||||
|
||||
* **ARB-03** shipped a call-site scan asserting that every `claims.append` in
|
||||
`cycle()` routes through `actuator_of()`. Its own parse **saw 3 of the 8
|
||||
@@ -167,6 +175,44 @@ COMMITTED EVIDENCE ARTIFACT four documents cite.
|
||||
than against its behaviour. It now drives the shipped `run_control()` on a
|
||||
two-inverter config, **under a deadline**, because the mutation's real symptom
|
||||
is that the controller enters its loop and never returns.
|
||||
* **MAINT-05** shipped `Controller.__init__` calling
|
||||
`migrate_maint_keys(store, self.inverters[0].name, ...)` under a comment
|
||||
saying *"it targets `self.inverters[0].name` and NOT `UNIT_A` ... writing
|
||||
`UNIT_A` here would deposit an install's whole maintenance history under a
|
||||
name that is not on the roster at all"*. `inverter.UNIT_A` **is** the string
|
||||
`"inverter-a"`, and every two-pack fixture in `test_maintenance.py` named its
|
||||
first roster entry `inverter-a` — so the two expressions were the same value
|
||||
in every check that existed, and swapping them left **all 19 files green**
|
||||
while losing a real install's whole maintenance history. Two-pack fixtures are
|
||||
now `["garage", "shed"]`, each behind a precondition check (habit 1) that the
|
||||
first name is not `UNIT_A`.
|
||||
|
||||
⚠️ **AND THE POSTCONDITION HAD THE SAME SHAPE AS THE FIXTURE.**
|
||||
`store._verify_moves()` read back the keys it had just written, under the
|
||||
namespace it had just been handed — so it verified clean, and the caller
|
||||
stamped the schema marker, on a migration nothing would ever read. *A check
|
||||
that reads back the namespace it was handed cannot detect being handed the
|
||||
wrong one*: it compared a thing against itself, exactly as DEV-02's fixture
|
||||
compared `(-5000, 5000)` against `(-5000, 5000)`. The habit-2 fix is the same
|
||||
one — grade against something the thing under test did not supply, here the
|
||||
ROSTER the machines read.
|
||||
|
||||
⚠️ **AND THE FIX ITSELF CARRIED THE DEFECT, WHICH IS THE SIXTH CARD IN A ROW
|
||||
AND THE FIRST TIME IT HAS APPEARED *INSIDE* A REMEDY.** The fix round's
|
||||
recovery check was `migrate_maint_keys(_m5, ROSTER[0], ROSTER)` — the
|
||||
**corrected** name. It measures recovery along the one path where the operator
|
||||
has *already fixed the bug*, and nothing in the 19 files called
|
||||
`migrate_maint_keys()` twice with the **same wrong** `unit`. So the refusal
|
||||
the card was rejected twice to obtain lasted **exactly one start**: measured
|
||||
at Controller level over one persisted store, roster `["garage", "shed"]` —
|
||||
construction 1 `ok=False misdirected=4 moved=4 kept=0 marker=<absent>`,
|
||||
construction 2 `ok=True misdirected=0 moved=0 kept=4 marker=1`. On start 2
|
||||
rule 1 routes the wrongly-written keys to `rep.kept`, `rep.moved` is empty,
|
||||
the roster loop iterates over nothing, and the marker is stamped on a
|
||||
migration that reached no readable key — after which the early return skips it
|
||||
forever, *including after the call site is fixed*. The check was true and
|
||||
passed for the wrong reason. Habit **9** below is what falls out of it.
|
||||
|
||||
* **CFG-04's `tools/supervisor_shape_probe.py` §B** — and this one is the rule
|
||||
reaching outside the suite. The probe is the committed evidence that
|
||||
`config.yaml`'s `inverters: []` default is load-bearing, and four documents
|
||||
@@ -241,6 +287,18 @@ Cheap habits fall out of it, and all of them are now used in this repository:
|
||||
red. `inverters: []` was deleted from `config.yaml` and the probe re-run
|
||||
against `ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0` for
|
||||
exactly that reason.
|
||||
9. **Exercise a refusal a SECOND time with the SAME wrong input — not the
|
||||
corrected one.** A guard that refuses once and then admits the same bad
|
||||
caller is not a guard, it is a delay, and the second call is a *different
|
||||
code path* whenever the first call left state behind. MAINT-05's roster
|
||||
grading iterated the keys it had just **written**; on the second start the
|
||||
same wrong caller found them already present, they moved to the
|
||||
`already namespaced` list, and the loop graded an empty set. Re-running with
|
||||
the **fixed** argument — which is what the check did — measures the operator's
|
||||
recovery, never the persistence of the refusal. Ask of every refusal: *what
|
||||
does this do when the caller has not been fixed and simply runs again?* And
|
||||
assert the **shape** of that second report, not only its verdict, so the
|
||||
check cannot silently revert to grading the first path.
|
||||
|
||||
And the mutation-table consequence: **a variant is not covered because a
|
||||
near-miss of it is.** DEV-02's table listed the *actuator* variant of the
|
||||
@@ -297,6 +355,8 @@ commit and PR bodies.
|
||||
| **TARIFF-01** reviewer survivor: `record_block()` ignoring its `policy` argument (0dbd485) | **re-verified — still a survivor** | re-run here through `tools/mutation_run.sh` against the 15 suites that were on the record, all green with `billed_w(block, policy)` mutated to `billed_w(block, POLICY_NET)`. The recorded diagnosis holds: every block reaching the store is single-phase, where NET, SUM and MAX collapse. **Now CLOSED by TEST-13** (`test_tariff.py` section 7), which round-trips section 7's own unbalanced `(3000, 500, -200) W` block THROUGH the store under each policy - three distinct banked figures, so a hardcoded policy takes at least two of them red. Third instance of "a stimulus evaluated where the quantity it grades is degenerate", after WITNESS-02's span normalisation and TARIFF-01's own DST window. |
|
||||
| **SAFETY-25** 8 mutations against `test_peakguard.py` part 10, then 9 more after review, all red | **not at risk** | each run against a tree copied fresh with `__pycache__` excluded and mounted `:ro`, so no `.pyc` existed to go stale - the same structural immunity recorded for CI above. Byte deltas recorded on the PR; none is `+0 B`. All are **reds**, which is the direction this defect cannot fabricate. ⚠️ The second round exists because the first round's mutations were all aimed at DISARMING the guard, and the claim part 10 actually made was about the guard being FIXED - the reviewer built the fix and the suite stayed green. Bytecode was never the issue there; an unaimed battery was. |
|
||||
| **SAFETY-03** reviewer survivor: `abs()` dropped from `clamp_to_rating`'s limit (6aabb83) | **re-verified — still a survivor** | re-run the same way, all 15 green. Also as recorded: unreachable under the `int(100, 5000)` schema. |
|
||||
| **MAINT-05 round 3**, `migrate_maint_keys()` marker gate `if rep.ok:` → `if rep.ok or rep.kept:` (`+12 B`) | **was a survivor — now CLOSED** | measured against head `65cddf3` under the purge, tree mounted `:ro`, `19/19 PASS`. It stamps the schema marker on a migration that LOST state, defeating the older `lost` guard as well as the new `misdirected` one, because every check that reached the marker did so on a store whose `kept` list was empty. Closed by `test_maintenance.py` **9d**; the mutation is now red on three named checks. |
|
||||
| **MAINT-05 round 3**, `migrate_unit_keys()` marker gate `if rep.ok:` → `if rep.ok or rep.kept:` (`+12 B`) | **found here — SAFETY-02's half, now CLOSED** | the SAME mutation one function up, on the LATCH migration rather than the history one. Measured a survivor against this branch under the purge, `:ro`, `19/19 PASS`, then closed by `test_inverter.py` part 10's new fixture — a store with `unit/inverter-a/sign_reason` already present (so `kept` is non-empty) whose `sign_tripped: true` write is dropped. Shipped: marker withheld. Mutant: marker stamped on a **disarmed latch**, and the next start skips the migration that would have re-armed it. |
|
||||
| **TARIFF-01**'s other three survivors, **SAFETY-03**'s `describe()` survivor, **TARIFF-02**'s M3/M5/M7, **SAFETY-18**'s three | **still unverified** | recorded before the purge discipline, with no byte delta on the record, so a `+0 B` same-second revert cannot be excluded. All are survivors, which is the direction this defect fabricates. TARIFF-02's and SAFETY-18's were **closed by later commits whose claims are reds**, so what is unverified is the *diagnosis*, not the current state of the code. |
|
||||
|
||||
**Nothing here says a past result is wrong.** The two survivors re-run above
|
||||
|
||||
@@ -151,6 +151,30 @@ CLAIM_SCOPE = {
|
||||
# other went on feeding the loop. The evidence is site-level and so is the
|
||||
# remedy: stop commanding, everywhere, and say why.
|
||||
"circulation": SCOPE_SITE,
|
||||
# main.py: `Claim.set("sign_site", P_SAFETY, 0.0, "site sign disagreement")`.
|
||||
# SAFETY-30, and it is the twin of `failsafe` below rather than a duplicate
|
||||
# of it - the two exist BECAUSE the same words describe two different
|
||||
# measurements once there is more than one inverter.
|
||||
#
|
||||
# `failsafe` grades ONE unit's standing command against THAT UNIT'S OWN
|
||||
# measured power (register 0x0518). Its conclusion is "the actuator I am
|
||||
# driving is not doing what I told it", which is a fact about one device,
|
||||
# so it parks one device.
|
||||
#
|
||||
# This one grades the SUM of the standing commands against P1. Its
|
||||
# conclusion is "the site as a whole is driving the wrong way" - an inverted
|
||||
# gain, an integrator wound past the rail, a strategy on the wrong side of
|
||||
# the meter - and there is nothing per-unit about it: the quantity is a sum
|
||||
# over the roster and the offending number is the site target, which no
|
||||
# single inverter owns. Parking one unit on that evidence would leave the
|
||||
# rest of the site pushing the same way with the guard satisfied.
|
||||
#
|
||||
# ⚠️ AT N=1 IT IS NEVER FILED, and that is the identity rather than a
|
||||
# special case: with one inverter the sum of the commands IS that unit's
|
||||
# command and `failsafe` already carries exactly this trip, under the keys,
|
||||
# the banner and the claim an install has had since SAFETY-02 shipped.
|
||||
# `Controller.cycle()` does not even arm the site detector there.
|
||||
"sign_site": SCOPE_SITE,
|
||||
|
||||
# --- UNIT: about one pack, one inverter, one device -------------------
|
||||
# main.py: `Claim.limit("device", P_SAFETY, self.dev_min, self.dev_max,
|
||||
@@ -164,13 +188,22 @@ CLAIM_SCOPE = {
|
||||
# same reason, so it is scoped like `device`.
|
||||
"supervised": SCOPE_UNIT,
|
||||
# main.py: `Claim.set("failsafe", P_SAFETY, 0.0, "sign disagreement")`.
|
||||
# ⚠️ THE EVIDENCE IS SITE-WIDE AND THE REMEDY IS NOT, and that is why this
|
||||
# entry needs its reasoning written down. SAFETY-02 compares P1 - a site
|
||||
# measurement - against `standing`, THE COMMAND THIS CONTROLLER PUT ON THIS
|
||||
# ACTUATOR. What it concludes is "the unit I am driving is pushing power the
|
||||
# wrong way", and what it does is park that unit. At N>=2 the same evidence
|
||||
# cannot be attributed to a sibling nobody here commands, so a site-wide
|
||||
# remedy would be this watchdog stopping an inverter it never graded.
|
||||
# ⚠️ THE EVIDENCE IS PER-UNIT AND SO IS THE REMEDY - AND SINCE SAFETY-30 THE
|
||||
# FIRST HALF OF THAT SENTENCE IS TRUE. It used to read "the evidence is
|
||||
# site-wide and the remedy is not", because the watchdog compared THIS
|
||||
# unit's standing command against P1: a site measurement, attributed to one
|
||||
# actuator on the strength of §6.2's N=1 identity. That identity does not
|
||||
# survive a second inverter - at N>=2 the meter answers for a sibling this
|
||||
# unit's command says nothing about, in both directions (a false trip when
|
||||
# the sibling covers the meter, and a missed one when the sibling MASKS a
|
||||
# unit that really is reversed).
|
||||
#
|
||||
# So at N>=2 the comparison behind this claim is THIS unit's command against
|
||||
# THIS unit's own measured power - register 0x0518, per-instance since
|
||||
# DEV-02 - and the scope that was already right for the wrong reason is now
|
||||
# right for the right one. The site-wide half moved to `sign_site` above.
|
||||
# At N=1 the two are the same comparison and this claim is the one filed,
|
||||
# exactly as it shipped.
|
||||
"failsafe": SCOPE_UNIT,
|
||||
# main.py: `Claim.set("maintenance", P_MAINTENANCE, ...)` when the cycle owns
|
||||
# the setpoint, and `Claim.limit("maintenance", P_MAINT_SHAPE, hi=...)` when
|
||||
|
||||
+634
-121
@@ -54,17 +54,22 @@ from .hass import HomeAssistant
|
||||
# window an operator would look up here is the one the roster actually uses.
|
||||
from .inverter import (LINK_STALE_S, UNIT_A, build_roster,
|
||||
roster_entries)
|
||||
from .maintenance import IDLE, MaintConfig, Maintenance
|
||||
from .maintenance import (
|
||||
IDLE, POWER_MOVING, MaintConfig, Maintenance, arbitrate as maint_arbitrate,
|
||||
)
|
||||
from .mqtt import MqttPublisher
|
||||
from . import peakguard
|
||||
from .p1 import P1Ingest, build_source, is_enabled
|
||||
from .price import Uncertainty, price_option
|
||||
from .static_tariff import resolve_tariff, static_status
|
||||
from .tariff import PeakStore, PeakTracker
|
||||
from .store import migrate_unit_keys
|
||||
from .store import migrate_maint_keys, migrate_unit_keys
|
||||
from .validate import (ConfigRefused, refuse, validate_startup_config,
|
||||
validate_unit_ranges)
|
||||
from .watchdog import SignWatchdogConfig, loop_is_following
|
||||
from .watchdog import (
|
||||
AGAINST_METER, AGAINST_OWN_POWER, SIGN_OPTION_DEFAULTS,
|
||||
SignWatchdog, SignWatchdogConfig, loop_is_following,
|
||||
)
|
||||
from . import web
|
||||
|
||||
OPTIONS_PATH = "/data/options.json"
|
||||
@@ -173,10 +178,42 @@ class Controller:
|
||||
# first or every existing tripped install comes up ARMED, into the
|
||||
# fault, with a green banner - which is the exact failure the latch was
|
||||
# persisted to prevent, rebuilt by a key rename.
|
||||
sign_cfg = SignWatchdogConfig(
|
||||
# SAFETY-02's pair, and since SAFETY-30 it is THE SITE COMPARISON's
|
||||
# pair - which at the shipped roster of one is the same thing under a
|
||||
# more careful name. It is what `Inverter.sign_wd` is armed with at N=1,
|
||||
# byte for byte, and what the site detector is armed with at N>=2.
|
||||
self.sign_cfg = sign_cfg = SignWatchdogConfig(
|
||||
min_w=float(opts.get("sign_disagree_w", 300)),
|
||||
hold_s=float(opts.get("sign_disagree_s", 180)),
|
||||
)
|
||||
# SAFETY-30. THE PER-UNIT COMPARISON'S OWN PAIR, RE-DERIVED AT TWO
|
||||
# INVERTERS AND NOT CARRIED ACROSS. `sign_disagree_w` / `sign_disagree_s`
|
||||
# were measured on two SINGLE-INVERTER bus captures against a command
|
||||
# opposed to THE METER; this comparison is a command against ONE UNIT'S
|
||||
# OWN POWER, where the magnitudes, the transient and the worst
|
||||
# legitimate episode are all different quantities. watchdog.py's
|
||||
# SIGN_OPTION_DEFAULTS carries the campaign that produced these, and
|
||||
# DECISIONS/SAFETY-30-per-unit-sign.md carries the tables.
|
||||
self.unit_sign_cfg = SignWatchdogConfig(
|
||||
min_w=float(opts.get("unit_sign_disagree_w",
|
||||
SIGN_OPTION_DEFAULTS["unit_sign_disagree_w"])),
|
||||
hold_s=float(opts.get("unit_sign_disagree_s",
|
||||
SIGN_OPTION_DEFAULTS["unit_sign_disagree_s"])),
|
||||
)
|
||||
# SAFETY-30. THE SITE COMPARISON'S OWN PAIR, USED ONLY AT N>=2. The
|
||||
# threshold is the shipped 300 W - carried, because the argument behind
|
||||
# it is about the meter's noise floor and the deadband, neither of which
|
||||
# the roster touches - and the WINDOW is not, because the transient it
|
||||
# rejects is the loop crossing zero at `slew_w` per cycle across a rail
|
||||
# that IS the roster sum. Measured at both rosters on the same stimuli:
|
||||
# 110 s at one inverter, 215 s at two, against a 180 s hold. See
|
||||
# watchdog.SIGN_OPTION_DEFAULTS.
|
||||
self.site_sign_cfg = SignWatchdogConfig(
|
||||
min_w=float(opts.get("site_sign_disagree_w",
|
||||
SIGN_OPTION_DEFAULTS["site_sign_disagree_w"])),
|
||||
hold_s=float(opts.get("site_sign_disagree_s",
|
||||
SIGN_OPTION_DEFAULTS["site_sign_disagree_s"])),
|
||||
)
|
||||
self.store_migration = migrate_unit_keys(store, UNIT_A)
|
||||
self.inverters = build_roster(opts, store, sign_cfg)
|
||||
# ⚠️ CFG-04. SAY WHICH SHAPE IS IN FORCE, BECAUSE THE OTHER ONE'S KEYS
|
||||
@@ -230,7 +267,66 @@ class Controller:
|
||||
# maintenance.MAINT_OPTION_DEFAULTS before adding a ninth key: it goes
|
||||
# in config.yaml's `options:` and `schema:` blocks and in that dict, and
|
||||
# nowhere else.
|
||||
self.maint = Maintenance(MaintConfig.from_options(opts), store)
|
||||
# --- MAINT-05: ONE `Maintenance` PER ROSTER ENTRY --------------------
|
||||
# ⚠️ AND THE MIGRATION RUNS FIRST, FOR THE REASON THE SAFETY-02 ONE
|
||||
# DOES. These objects READ their history in their constructors' wake -
|
||||
# `phase`, `last_completed` - so a history still sitting under the flat
|
||||
# spelling when they are built is a pack that comes up believing it has
|
||||
# never been recalibrated, on a site whose state file says otherwise.
|
||||
# It targets `self.inverters[0].name` and NOT `UNIT_A`: the flat keys
|
||||
# belonged to whichever pack the one FSM was driving, which is the first
|
||||
# roster entry, and a declared `inverters:` roster names its own entries
|
||||
# (`inverter.build_roster()` says so, and its fallback for a nameless
|
||||
# entry is a POSITIONAL `inverter-1`, so `inverter-a` is not even the
|
||||
# default there). Writing `UNIT_A` here would deposit an install's whole
|
||||
# maintenance history under a name that is not on the roster at all.
|
||||
#
|
||||
# ⚠️ AND THAT SENTENCE USED TO BE A COMMENT NOTHING COULD GRADE, WHICH
|
||||
# IS WHY THE ROSTER IS PASSED RATHER THAN A COUNT. Every two-pack
|
||||
# fixture in the suite named its first entry `inverter-a`, so
|
||||
# `self.inverters[0].name` and `UNIT_A` were the same string in every
|
||||
# check that existed and swapping them left all 19 files green - while
|
||||
# on a roster of `["garage", "shed"]` it silently loses the history and
|
||||
# stamps the marker, so the next start skips the migration too.
|
||||
# `migrate_maint_keys()` now grades the namespace it wrote against the
|
||||
# names the machines read; test_maintenance.py sections 9 and 11 drive
|
||||
# a `["garage", "shed"]` roster, which is what makes the mutation red
|
||||
# instead of invisible.
|
||||
self.maint_migration = migrate_maint_keys(
|
||||
store, self.inverters[0].name, [inv.name for inv in self.inverters])
|
||||
_LOG.info("maintenance history: %s", self.maint_migration.explain())
|
||||
if not self.maint_migration.ok:
|
||||
# Not a disarmed guard - history, not a latch - so it does not
|
||||
# re-arm anything. It is still the difference between a pack that is
|
||||
# recalibrated on schedule and one that silently is not, which is
|
||||
# §12's opening sentence, so it is said where an operator looks.
|
||||
self.log_event("maintenance history did NOT migrate cleanly: "
|
||||
+ self.maint_migration.explain())
|
||||
# ⚠️ ONE CONFIG, N MACHINES. The `maintenance_*` options describe the
|
||||
# PROCEDURE - how hard to drain, how full to charge, how long to hold -
|
||||
# and the procedure is the same on every pack in the roster; what is per
|
||||
# pack is the SCHEDULE and the HISTORY, which live in the store. A
|
||||
# per-entry config block would be a second shape for CFG-04's roster to
|
||||
# carry and a fifth place for a `maintenance_charge_w` to disagree with
|
||||
# config.yaml. If a site ever needs two different procedures, that is a
|
||||
# roster-schema card and it starts here.
|
||||
_maint_cfg = MaintConfig.from_options(opts)
|
||||
_one_pack = len(self.inverters) <= 1
|
||||
self.maints = [
|
||||
Maintenance(
|
||||
_maint_cfg, store,
|
||||
# ⚠️ `None` AT A ROSTER OF ONE IS THE FLAT LAYOUT, NOT A MISSING
|
||||
# NAME. §6.2's identity: one pack, one history, and the keys it
|
||||
# has been written under since the add-on shipped. See
|
||||
# `maintenance.UnitHistory` and `store.migrate_maint_keys()` -
|
||||
# this is the line that keeps a one-inverter state file
|
||||
# byte-identical.
|
||||
unit=None if _one_pack else inv.name,
|
||||
name=inv.name,
|
||||
# The rollback view, and only ever the first pack's: the flat
|
||||
# keys mean `inverters[0]` on every install that has them.
|
||||
mirror_flat=(not _one_pack and i == 0))
|
||||
for i, inv in enumerate(self.inverters)]
|
||||
|
||||
# SAFETY-02. ONE INSTANCE PER ACTUATOR - which is what watchdog.py's own
|
||||
# docstring has always said and what this Controller did not do. Each
|
||||
@@ -261,6 +357,45 @@ class Controller:
|
||||
"opposed the meter.", inv.name,
|
||||
inv.sign_wd.reason or "(reason not recorded)")
|
||||
|
||||
# --- SAFETY-30: THE SITE HALF OF THE SIGN CHECK ----------------------
|
||||
# ⚠️ ONE PER SITE, BESIDE THE ONE PER INVERTER, AND ARMED ONLY AT N>=2.
|
||||
# The per-unit watchdogs above ask "is THIS actuator doing what I told
|
||||
# it", graded on that unit's own measured power. This one asks "is the
|
||||
# SITE driving the wrong way", graded on the SUM of the standing
|
||||
# commands against P1 - the comparison SAFETY-02 shipped, re-scoped to
|
||||
# the quantity it was always actually about.
|
||||
#
|
||||
# ⚠️ AT A ROSTER OF ONE IT IS CONSTRUCTED AND NEVER EVALUATED, and that
|
||||
# is the whole compatibility promise of this card rather than an
|
||||
# oversight. With one inverter the sum of the commands IS that
|
||||
# inverter's command, so arming this would be arming a duplicate of
|
||||
# `inverters[0].sign_wd`: two latches for one fault, two banners, and a
|
||||
# false-positive record measured on ONE comparison being spent twice.
|
||||
# `cycle()` is where that is enforced and says so at the line.
|
||||
#
|
||||
# Restored from the store like SAFETY-02's and SAFETY-31's latches, for
|
||||
# the reason store.py gives: "restart the add-on" is the first thing an
|
||||
# operator looking at a FAILSAFE banner tries, and a latch held only in
|
||||
# memory brings the controller back armed, into the fault, unattended.
|
||||
# FLAT keys, not namespaced - store.py carries that argument too.
|
||||
self.site_sign_wd = SignWatchdog(
|
||||
self.site_sign_cfg,
|
||||
tripped=bool(store.data.get("site_sign_tripped", False)),
|
||||
reason=str(store.data.get("site_sign_reason", "") or ""))
|
||||
if self.site_sign_wd.tripped:
|
||||
_LOG.error(
|
||||
"SAFETY-30 (site) was TRIPPED before this restart and stays "
|
||||
"tripped: %s. Every inverter is held at 0 W. Restarting does "
|
||||
"not clear this - start control from the UI once you know why "
|
||||
"the site's total command opposed the meter.",
|
||||
self.site_sign_wd.reason or "(reason not recorded)")
|
||||
# And the per-unit detectors are told which question they are asking,
|
||||
# here as well as in `cycle()`. `checks()` and the status page read
|
||||
# `inv.sign_wd.cfg` and can be called before the first cycle has run, so
|
||||
# a roster of two would otherwise advertise the site thresholds on a
|
||||
# detector that is about to be graded against a unit's own power.
|
||||
self._arm_sign_watchdogs()
|
||||
|
||||
# SAFETY-18. The frozen-but-fresh meter detector - see freeze.py for why
|
||||
# it is a conjunction and not an `unchanged_s` threshold, and for the
|
||||
# measurements behind the default.
|
||||
@@ -379,6 +514,9 @@ class Controller:
|
||||
self._peak_saturated = False
|
||||
self._peak_floor_limited = False
|
||||
self._maint_shape_suspended = False
|
||||
# [(pack name, why)] for packs that are due and waiting their turn.
|
||||
# Empty at a roster of one, where nothing can defer anything.
|
||||
self._maint_deferred = []
|
||||
# Set by amain() once the transport is built, so the status page can show
|
||||
# what only the transport knows (homewizard_local's unchanged_s). Stays
|
||||
# None when P1 is off, or under a transport that has no such counter.
|
||||
@@ -593,18 +731,79 @@ class Controller:
|
||||
return tuple(inv.name for inv in self.inverters)
|
||||
|
||||
@property
|
||||
def maint_unit(self):
|
||||
"""The pack the ONE maintenance state machine is recalibrating.
|
||||
def maint_index(self) -> int:
|
||||
"""Which roster slot holds the site's ONE maintenance slot right now.
|
||||
|
||||
⚠️ NAMED RATHER THAN ASSUMED. This add-on holds exactly one
|
||||
`Maintenance`, whose history lives under the store's un-namespaced
|
||||
`phase` / `last_completed` keys, so the pack it drives is the first in
|
||||
the roster. Two packs recalibrating on two schedules needs a second FSM
|
||||
and a namespaced history of its own; what THIS card fixes is only that
|
||||
the claim is filed on ONE actuator instead of on whichever one happened
|
||||
to be asked. Read store.LEGACY_UNIT_KEYS on why those keys did not move.
|
||||
The pack that is mid-cycle if there is one, otherwise the first - which
|
||||
at a roster of one is always 0, always was, and is the whole of this
|
||||
property's N=1 behaviour.
|
||||
"""
|
||||
return self.inverters[0]
|
||||
for i, m in enumerate(self.maints):
|
||||
if m.phase in POWER_MOVING:
|
||||
return i
|
||||
return 0
|
||||
|
||||
@property
|
||||
def maint(self):
|
||||
"""The `Maintenance` the site's one maintenance slot belongs to.
|
||||
|
||||
⚠️ MAINT-05 TURNED THIS FROM AN ATTRIBUTE INTO A VIEW, AND THE THING IT
|
||||
IS A VIEW OF CHANGED WITH IT. There are now `self.maints` - one FSM per
|
||||
roster entry, each with its own schedule, phase and history - and every
|
||||
SITE-level surface that used to read `self.maint` (the `phase` MQTT
|
||||
value, the status banner, the operator's start/abort buttons) wants THE
|
||||
ONE THAT IS RECALIBRATING, not "the first one". `maintenance.arbitrate()`
|
||||
guarantees at most one pack is ever out of IDLE, so "the one that is
|
||||
recalibrating" is well defined; when none is, this is `maints[0]` and
|
||||
the surfaces read exactly what they read before.
|
||||
|
||||
⚠️ AT A ROSTER OF ONE IT IS `maints[0]` ON EVERY TICK, in both branches,
|
||||
which is the object that used to be assigned here. Nothing downstream
|
||||
can tell the difference - that is AC 6, and test_maintenance.py part 9
|
||||
asserts it rather than trusting this paragraph.
|
||||
"""
|
||||
return self.maints[self.maint_index]
|
||||
|
||||
@property
|
||||
def maint_unit(self):
|
||||
"""The pack the site's one maintenance slot is currently on.
|
||||
|
||||
⚠️ THIS USED TO BE `self.inverters[0]`, FLATLY, AND THE COMMENT THAT
|
||||
STOOD HERE EXPLAINED WHY: there was exactly one `Maintenance`, its
|
||||
history lived under the store's un-namespaced `phase` / `last_completed`
|
||||
keys, so the pack it drove could only be the first in the roster. That
|
||||
sentence is what MAINT-05 removed. There is now one FSM and one
|
||||
namespaced history PER ROSTER ENTRY, so the pack being recalibrated is
|
||||
whichever one holds the site's maintenance slot, and `maint_index` -
|
||||
not the roster's order - is what answers it.
|
||||
|
||||
⚠️ AND `validate.py` RULE 6 MOVED WITH IT, exactly as its own comment
|
||||
said it must ("when `maint_unit` stops being `inverters[0]`, this line
|
||||
moves with it"). It graded `maintenance_charge_w` against the FIRST
|
||||
entry's cap on the argument that the cycle never touches the others;
|
||||
that argument is now false, so it grades against the weakest cap on the
|
||||
roster, like rule 5. See the ⚠️ block there.
|
||||
"""
|
||||
return self.inverters[self.maint_index]
|
||||
|
||||
def _maint_button(self, now):
|
||||
"""The pack an operator's one maintenance button acts on.
|
||||
|
||||
The pack holding the site's maintenance slot when one holds it, so
|
||||
"abort" stops the cycle that is running and "start" restarts it -
|
||||
exactly what both buttons meant while there was one pack, and the reason
|
||||
this is not simply "the longest-waiting one". When every pack is idle it
|
||||
IS the longest-waiting one, which is `arbitrate()`'s own clause 2, so a
|
||||
forced start and a scheduled start choose the same pack rather than two
|
||||
different ones.
|
||||
|
||||
⚠️ AT A ROSTER OF ONE BOTH BRANCHES ARE `maints[0]`. There is no third
|
||||
case: `max()` over a one-element list is that element.
|
||||
"""
|
||||
if self.maints[self.maint_index].phase in POWER_MOVING:
|
||||
return self.maints[self.maint_index]
|
||||
return max(enumerate(self.maints),
|
||||
key=lambda p: (p[1].waited_days(now), -p[0]))[1]
|
||||
|
||||
def inverter(self, name: str):
|
||||
"""The roster entry called `name`, or None."""
|
||||
@@ -712,6 +911,45 @@ class Controller:
|
||||
def sign_wd(self):
|
||||
return self._only().sign_wd
|
||||
|
||||
# -- SAFETY-30: which comparison each sign detector is making -------------
|
||||
def _arm_sign_watchdogs(self) -> None:
|
||||
"""Tell every sign detector which of SAFETY-30's two questions it asks.
|
||||
|
||||
⚠️ A PURE FUNCTION OF `len(self.inverters)`, AND THE ONLY PLACE THE
|
||||
ROSTER DECIDES ANYTHING ABOUT THIS CHECK. Written as one method rather
|
||||
than as a conditional at the two call sites for `loop_is_following()`'s
|
||||
reason: the arrangement that does not keep two things in step is the one
|
||||
where they are written down twice.
|
||||
|
||||
AT ONE INVERTER - §6.2's identity, and the whole of AC 8. The single
|
||||
unit's detector is armed against THE METER with the shipped
|
||||
`sign_disagree_w` / `sign_disagree_s`, which is what it has always been
|
||||
armed against, and the site detector is not armed at all. A one-inverter
|
||||
install therefore makes the same comparison, at the same thresholds,
|
||||
writes the same reason string, latches under the same keys and files the
|
||||
same `failsafe` claim as it did before this card.
|
||||
|
||||
AT TWO OR MORE - the identity is gone and the meter stops being a view
|
||||
of any one actuator. Each unit's detector is armed against ITS OWN
|
||||
MEASURED POWER (`Inverter.batt`, register 0x0518) under the re-derived
|
||||
per-unit pair, and the site detector is armed against the meter under
|
||||
the site pair. Two questions, two remedies, two latches.
|
||||
|
||||
⚠️ CALLED AGAIN AT THE TOP OF EVERY `cycle()`, not only from
|
||||
`__init__`. The roster is re-read every cycle for liveness and for the
|
||||
allocation, and this repository's two-inverter fixtures append an
|
||||
`Inverter` AFTER the Controller is constructed - a detector frozen at
|
||||
construction would then be graded against the meter at a roster of two,
|
||||
which is the defect this card exists to remove, wearing a fixture's
|
||||
name. `arm()` touches no timer and no latch, so calling it every cycle
|
||||
cannot disturb an episode in progress.
|
||||
"""
|
||||
one = len(self.inverters) <= 1
|
||||
for inv in self.inverters:
|
||||
inv.sign_wd.arm(self.sign_cfg if one else self.unit_sign_cfg,
|
||||
AGAINST_METER if one else AGAINST_OWN_POWER)
|
||||
self.site_sign_wd.arm(self.site_sign_cfg, AGAINST_METER)
|
||||
|
||||
# -- the site aggregates, each one named for the question it answers ------
|
||||
# ⚠️ THESE ARE NOT "THE SCALARS WITH A SUM IN FRONT". Each one picks a
|
||||
# DIFFERENT reduction, because the questions are different, and getting the
|
||||
@@ -1216,14 +1454,36 @@ class Controller:
|
||||
"""
|
||||
now = datetime.now(timezone.utc)
|
||||
|
||||
# ⚠️ THE PACK IT IS MAINTAINING, NOT "the SoC". §12's recalibration
|
||||
# drains and refills ONE pack and grades ONE coulomb counter, so it is
|
||||
# graded on that pack's own reading - see `maint_unit`. A minimum across
|
||||
# packs would abort the cycle on a sibling's state, and an average would
|
||||
# declare a pack full that is not.
|
||||
result = self.maint.tick(now, self.maint_unit.soc)
|
||||
for msg in result.events:
|
||||
self.log_event(msg)
|
||||
# ⚠️ EACH PACK ON ITS OWN READING, NOT "the SoC". §12's recalibration
|
||||
# drains and refills ONE pack and grades ONE coulomb counter, so each
|
||||
# state machine is ticked with the SoC of the inverter it belongs to. A
|
||||
# minimum across packs would abort a cycle on a sibling's state, and an
|
||||
# average would declare a pack full that is not. The pairing is
|
||||
# positional and both lists are built from the roster in `__init__`, so
|
||||
# a pack cannot be graded on its neighbour's meter.
|
||||
#
|
||||
# ⚠️ AND `arbitrate()` RUNS FIRST, ONCE, OVER ALL OF THEM. It is the
|
||||
# site's one maintenance slot - see maintenance.py - and a pack that
|
||||
# does not hold it is told so by name rather than left to discover it.
|
||||
# Calling `tick()` without the answer this produced is the
|
||||
# two-packs-draining-at-once defect with the interlock present but not
|
||||
# wired, which is why the plan is built here and not inside the loop.
|
||||
maint_plan = maint_arbitrate(self.maints, now)
|
||||
maint_results = []
|
||||
for inv, machine, blocked in zip(self.inverters, self.maints, maint_plan):
|
||||
res = machine.tick(now, inv.soc, blocked_by=blocked)
|
||||
for msg in res.events:
|
||||
self.log_event(msg)
|
||||
maint_results.append(res)
|
||||
# ⚠️ CARRIED TO THE STATUS PAGE, NOT LEFT IN THE 40-LINE ACTION LOG. The
|
||||
# deferral is edge-logged (it lasts as long as the other pack's cycle),
|
||||
# so by the time an operator asks "why has pack B not recalibrated" the
|
||||
# line that said so has scrolled off. §12's whole failure mode is a
|
||||
# schedule that silently stops firing; a pack that is due, idle and
|
||||
# WAITING has to be able to say so at the moment it is looked at.
|
||||
self._maint_deferred = [(m.name, r.deferred)
|
||||
for m, r in zip(self.maints, maint_results)
|
||||
if r.deferred]
|
||||
|
||||
# --- SAFETY-02, and it runs BEFORE the early return below -------------
|
||||
# ⚠️ ORDER MATTERS HERE. If this were evaluated after the "inputs missing
|
||||
@@ -1239,17 +1499,44 @@ class Controller:
|
||||
# case where the last write was REJECTED - the inverter is then still
|
||||
# latched on `last_write`, which is exactly what `last_write` holds).
|
||||
# ⚠️ ONE WATCHDOG PER INVERTER, EVALUATED ON THAT INVERTER'S OWN
|
||||
# STANDING COMMAND. The meter is site-wide - there is one P1 - but what
|
||||
# the watchdog concludes is "THE UNIT I AM DRIVING is pushing power the
|
||||
# wrong way", and that evidence cannot be pinned on a sibling this
|
||||
# controller commanded differently. `inv.target` is that unit's share
|
||||
# from the last resolution, which at N=1 is the site target itself.
|
||||
# STANDING COMMAND. What the watchdog concludes is "THE UNIT I AM
|
||||
# DRIVING is pushing power the wrong way", and that evidence cannot be
|
||||
# pinned on a sibling this controller commanded differently.
|
||||
# `inv.target` is that unit's share from the last resolution, which at
|
||||
# N=1 is the site target itself.
|
||||
#
|
||||
# ⚠️ SAFETY-30: AND WHAT IT IS COMPARED AGAINST IS DECIDED BY THE ROSTER.
|
||||
# This block used to hand every unit's detector `self.grid`. There is
|
||||
# ONE P1, so at N>=2 that compares a number this controller put on ONE
|
||||
# actuator against a measurement that answers for ALL of them, and it is
|
||||
# wrong in both directions:
|
||||
#
|
||||
# FALSE TRIP inverter A commanded -1500 W while the meter reads
|
||||
# +1500 W is evidence of nothing when inverter B is
|
||||
# discharging 3000 W exactly as instructed. Nothing is
|
||||
# faulty and the highest-value check in the safety table
|
||||
# fires - on a record of zero false positives.
|
||||
# MISSED the converse, and it is worse. A unit commanded +1500 W
|
||||
# and MEASURED at -1500 W, beside a sibling at +1500 W,
|
||||
# leaves P1 exactly where a healthy site leaves it. The
|
||||
# sum destroys the evidence; no threshold recovers it.
|
||||
#
|
||||
# So at N>=2 each unit is graded against ITS OWN measured power -
|
||||
# `inv.batt`, register 0x0518, per-instance since DEV-02 - which is the
|
||||
# only instrument that can answer "is THIS actuator doing what I told
|
||||
# it". At N=1 §6.2's identity holds, the meter IS the view of that one
|
||||
# unit, and the comparison stays the meter, byte for byte. The site's
|
||||
# own question has not gone away; it is asked below, once, of the sum.
|
||||
# `_arm_sign_watchdogs()` states the choice and its docstring argues it.
|
||||
self._arm_sign_watchdogs()
|
||||
n_units = len(self.inverters)
|
||||
standing = {}
|
||||
for inv in self.inverters:
|
||||
was_tripped = inv.sign_wd.tripped
|
||||
stood = inv.last_write if inv.last_write is not None else inv.target
|
||||
standing[inv.name] = stood
|
||||
if inv.sign_wd.evaluate(stood, self.grid, self.following, now) \
|
||||
against = self.grid if n_units <= 1 else inv.batt
|
||||
if inv.sign_wd.evaluate(stood, against, self.following, now) \
|
||||
and not was_tripped:
|
||||
# ⚠️ REASON FIRST, FLAG SECOND, and each `set` writes the file.
|
||||
# The ordering is the whole atomicity story: a crash between the
|
||||
@@ -1290,6 +1577,50 @@ class Controller:
|
||||
# share of it. At the shipped roster of one the two are the same number.
|
||||
site_standing = float(sum(standing.values()))
|
||||
|
||||
# --- SAFETY-30: THE SITE HALF OF THE SIGN CHECK ----------------------
|
||||
# The comparison SAFETY-02 shipped, asked of the quantity it was always
|
||||
# about: the TOTAL this controller has standing on the wire, against the
|
||||
# meter that total is answerable for. What it catches is a fault no
|
||||
# per-unit check can see, because every unit is faithfully executing its
|
||||
# share of a site target that is itself pointing the wrong way - an
|
||||
# inverted gain, an integrator wound past the rail, a strategy on the
|
||||
# wrong side of the meter. That is the 2026-08-20 fault day, and it is
|
||||
# the reason the site question survives rather than being replaced.
|
||||
#
|
||||
# ⚠️ ONLY AT N>=2, AND THIS BRANCH IS AC 8. At one inverter the sum of
|
||||
# the commands IS that inverter's command and the loop above has already
|
||||
# made exactly this comparison, at exactly these thresholds, on the
|
||||
# detector whose latch, store keys, claim and banner an install has had
|
||||
# since SAFETY-02 shipped. Arming this as well would be two latches for
|
||||
# one fault, two banners, and the same false-positive record spent
|
||||
# twice. A shipped install does not reach this block at all.
|
||||
if n_units > 1:
|
||||
was_site = self.site_sign_wd.tripped
|
||||
if self.site_sign_wd.evaluate(site_standing, self.grid,
|
||||
self.following, now) and not was_site:
|
||||
# REASON FIRST, FLAG SECOND - the same atomicity ordering the
|
||||
# per-unit trip uses above and SAFETY-31 uses below: a crash
|
||||
# between the two must not persist a latch with no explanation
|
||||
# for the operator who has to decide about clearing it.
|
||||
#
|
||||
# ⚠️ AND THE KEYS ARE FLAT, NOT NAMESPACED, AND NOT THE
|
||||
# PRE-DEV-02 PAIR EITHER. `sign_tripped` / `sign_reason` are the
|
||||
# ROLLBACK VIEW of a UNIT latch (store.py rule 2) and mirroring
|
||||
# a site trip onto them would hand a downgraded add-on - which
|
||||
# drives exactly one actuator - a latch taken on evidence about
|
||||
# a roster it cannot have. `site_sign_*` is its own pair, for
|
||||
# the same reason `circ_*` is.
|
||||
self.store.set("site_sign_reason", self.site_sign_wd.reason)
|
||||
self.store.set("site_sign_tripped", True)
|
||||
self.log_event("FAILSAFE site: " + self.site_sign_wd.reason)
|
||||
_LOG.error("SAFETY-30 TRIPPED at the SITE - %s. That is the "
|
||||
"SUM of every standing command opposing the meter, "
|
||||
"which no single inverter is answerable for. "
|
||||
"Commanding 0 W on every inverter and holding it "
|
||||
"until control is started again. This survives an "
|
||||
"add-on restart; restarting will not clear it.",
|
||||
self.site_sign_wd.reason)
|
||||
|
||||
# --- SAFETY-31, AND IT RUNS BESIDE SAFETY-02 FOR THE SAME REASON -----
|
||||
# Evaluated EVERY cycle, unconditionally, above the "inputs missing but
|
||||
# not yet stale" hold below. A run of held cycles would otherwise leave
|
||||
@@ -1329,8 +1660,14 @@ class Controller:
|
||||
# list below, because its `failsafe` SET is what parks it. One tripped
|
||||
# unit therefore takes the whole roster past the hold, which is the
|
||||
# conservative direction: every other unit's claims are re-filed too.
|
||||
# ⚠️ AND SAFETY-30's SITE LATCH TAKES THE ROSTER PAST THE HOLD TOO, for
|
||||
# the same reason: its `sign_site` SET is what parks every inverter, and
|
||||
# a latched site that returned early here would leave each unit's last
|
||||
# share standing for the heartbeat to re-emit - i.e. the trip would stop
|
||||
# acting the moment a poll was missed.
|
||||
if not self.inputs_ok and not any(i.sign_wd.tripped
|
||||
for i in self.inverters):
|
||||
for i in self.inverters) \
|
||||
and not (n_units > 1 and self.site_sign_wd.tripped):
|
||||
bad_for = (now - self.inputs_bad_since).total_seconds() if self.inputs_bad_since else 0.0
|
||||
if bad_for < stale_after:
|
||||
# A single missed poll is not a fault. Hold, keep the heartbeat
|
||||
@@ -1384,6 +1721,30 @@ class Controller:
|
||||
"sign disagreement",
|
||||
actuator=self.actuator_of("failsafe", inv)))
|
||||
|
||||
# --- SAFETY-30: THE SITE SIGN TRIP, AND IT IS A SITE SET ------------
|
||||
# ⚠️ THE TWIN OF THE LOOP ABOVE, NOT A DUPLICATE OF IT. That loop files
|
||||
# one `failsafe` per unit on the evidence of THAT unit's own measured
|
||||
# power, and parks that unit. This files ONE claim on the SITE, because
|
||||
# what tripped is the SUM of every standing command against the meter -
|
||||
# a fact about the grid connection, whose offending number is the site
|
||||
# target and which no single inverter owns. Parking one unit on it would
|
||||
# leave the rest of the roster pushing the same way with the guard
|
||||
# satisfied. See arbiter.CLAIM_SCOPE, which classifies `sign_site` and
|
||||
# `failsafe` side by side and says why they differ.
|
||||
#
|
||||
# ⚠️ AND THE `n_units > 1` GUARD IS NOT REDUNDANT, EVEN THOUGH `cycle()`
|
||||
# never arms this detector at a roster of one. The latch is RESTORED
|
||||
# FROM THE STORE, so an install that ran with two inverters, tripped,
|
||||
# and was then reconfigured back to one would come up with
|
||||
# `site_sign_tripped: true` and would otherwise file a claim on evidence
|
||||
# about a roster it no longer has. Guarded, that install comes up
|
||||
# driving - which is right: the fault it latched on is not a statement
|
||||
# about the site it is now.
|
||||
if n_units > 1 and self.site_sign_wd.tripped:
|
||||
claims.append(Claim.set("sign_site", P_SAFETY, 0.0,
|
||||
"site sign disagreement",
|
||||
actuator=self.actuator_of("sign_site")))
|
||||
|
||||
# --- SAFETY-31: WHAT "ACTED ON" MEANS, AND WHAT IT HONESTLY CANNOT --
|
||||
# ⚠️ A SITE SET AT P_SAFETY: STOP COMMANDING, EVERYWHERE. Read the next
|
||||
# paragraph before changing it, because the obvious objection is right
|
||||
@@ -1624,88 +1985,114 @@ class Controller:
|
||||
self.log_event(self.arb.explain())
|
||||
|
||||
# --- maintenance -----------------------------------------------------
|
||||
if result.owns_setpoint:
|
||||
# PER-INVERTER. §12's monthly recalibration is a PACK procedure -
|
||||
# drain THIS pack to its floor, charge THIS pack full, recalibrate
|
||||
# THIS pack's coulomb counter. Two packs recalibrate on two
|
||||
# schedules. See arbiter.CLAIM_SCOPE.
|
||||
# ⚠️ FILED ON THE UNIT BEING MAINTAINED, WHICH IS THE FIRST ONE.
|
||||
# §12's monthly recalibration is a PACK procedure and this add-on
|
||||
# holds exactly ONE `Maintenance` state machine, so the pack it is
|
||||
# maintaining is `self.maint_unit`. Two packs recalibrating on two
|
||||
# schedules is a second FSM with its own namespaced history, which
|
||||
# is a card of its own - what this card must not do is file one
|
||||
# pack's procedure on every actuator.
|
||||
claims.append(Claim.set("maintenance", P_MAINTENANCE,
|
||||
float(result.setpoint_w or 0.0), result.phase,
|
||||
actuator=self.actuator_of("maintenance",
|
||||
self.maint_unit)))
|
||||
self.sat_count = 0
|
||||
elif result.charge_only:
|
||||
# Money outranks the maintenance schedule: while the quarter-hour
|
||||
# projection is over the cap, the charge-only shaping is simply not
|
||||
# claimed, so the loop can discharge and shave the peak. When a
|
||||
# dedicated peak-shaving strategy arrives it will claim SET at
|
||||
# P_PEAK and outrank this limit without any code here changing.
|
||||
# ⚠️ AND SAFETY-07 IS THE OTHER HALF OF THIS CONDITION, NOT A
|
||||
# SECOND MECHANISM. The shaping is `hi <= 0`; the peak guard's claim
|
||||
# is `lo >= 0`. Both are limits, arbiter.py applies EVERY limit at or
|
||||
# above the winner's priority, and most restrictive wins - so a peak
|
||||
# event during a maintenance charge window files `lo > hi`, which is
|
||||
# a CONTRADICTION and resolves to 0 W. The battery would park in the
|
||||
# exact quarter it should be shaving. Priority does not save it:
|
||||
# clause 2 has no notion of a higher-priority limit overriding a
|
||||
# lower one, and it should not - "most restrictive" is what makes the
|
||||
# safety bounds unconditional.
|
||||
#
|
||||
# So the higher-priority claimant SUPPRESSES the lower one rather
|
||||
# than out-voting it, which is what this branch already did for
|
||||
# `peak_forecast_entity`. That entity is optional and empty on a
|
||||
# default install, so until now the suspension could not fire on the
|
||||
# site that needed it. `self.peak_guard` is measured from the meter
|
||||
# and is always there.
|
||||
#
|
||||
# ⚠️ THE CONJUNCTION LIVES IN peakguard.py, NOT HERE, and that is not
|
||||
# tidiness. It was inline, and a reviewer mutated it back to its
|
||||
# historical broken form - re-gated on `peak_forecast_entity` alone -
|
||||
# and every suite in this repository stayed green while a default
|
||||
# install parked at 0 W in the quarter that sets the month's bill.
|
||||
# Read shaping_suspended() before touching this: both terms are
|
||||
# there, and why neither is sufficient alone.
|
||||
if peakguard.shaping_suspended(
|
||||
self.peak_guard, self.peak_fc,
|
||||
float(self.o.get("peak_cap_w", 3500))):
|
||||
# Edge-logged: level-logging here would write one line per cycle
|
||||
# for as long as the event lasts and flush the 40-line action log
|
||||
# of the very context that explains it.
|
||||
if not self._maint_shape_suspended:
|
||||
self._maint_shape_suspended = True
|
||||
self.log_event("peak at risk - maintenance charge shaping "
|
||||
"suspended so the peak claim is not "
|
||||
"contradicted")
|
||||
else:
|
||||
self._maint_shape_suspended = False
|
||||
hi = 0.0
|
||||
reason = "charge-only"
|
||||
if self.cheap:
|
||||
# ⚠️ CFG-03. `self.maint.cfg.charge_w`, NOT A SECOND READ
|
||||
# OF `self.o`. This line used to re-open the options dict
|
||||
# with its own literal fallback, so the rate the shaping
|
||||
# asked for and the rate the state machine drained at could
|
||||
# be different numbers from the same install - and, with the
|
||||
# key absent, they were. The Controller already parsed this
|
||||
# once in __init__; asking the object that owns it cannot
|
||||
# drift from it.
|
||||
floor = maintenance_charge_floor(
|
||||
self.maint.cfg.charge_w,
|
||||
self.peak_fc, float(self.o.get("peak_cap_w", 3500)))
|
||||
if floor > 0:
|
||||
hi, reason = -floor, "cheap-window charge"
|
||||
# PER-INVERTER, like the SET above and for the same reason -
|
||||
# the shaping is about the pack being charged.
|
||||
claims.append(Claim.limit("maintenance", P_MAINT_SHAPE, hi=hi, reason=reason,
|
||||
actuator=self.actuator_of("maintenance",
|
||||
self.maint_unit)))
|
||||
# ⚠️ ONE PASS PER PACK, AND `arbitrate()` IS WHY THE LIST STAYS SHORT.
|
||||
# At most one machine is out of IDLE on any tick, so at most one of
|
||||
# these branches fires and the claim list is the shape it has always
|
||||
# been. The loop is not a widening of what maintenance may ask for; it
|
||||
# is what makes the ONE claim it does file land on the pack that is
|
||||
# actually being recalibrated, whichever roster slot that is.
|
||||
for inv, result in zip(self.inverters, maint_results):
|
||||
if result.owns_setpoint:
|
||||
# PER-INVERTER. §12's monthly recalibration is a PACK procedure -
|
||||
# drain THIS pack to its floor, charge THIS pack full,
|
||||
# recalibrate THIS pack's coulomb counter. Two packs recalibrate
|
||||
# on two schedules. See arbiter.CLAIM_SCOPE.
|
||||
#
|
||||
# ⚠️ FILED ON THE PACK WHOSE STATE MACHINE PRODUCED IT - `inv`,
|
||||
# the roster entry this `result` was ticked from - and that is
|
||||
# the whole of MAINT-05 at this line. It used to be
|
||||
# `self.maint_unit`, which was `inverters[0]` flatly, because
|
||||
# there was one FSM and its history had nowhere else to live.
|
||||
# Pack B's drain filed on pack A is one pack being commanded for
|
||||
# another's procedure while the pack that is actually draining
|
||||
# stays under the loop: the site would move the right total and
|
||||
# recalibrate nothing.
|
||||
#
|
||||
# ⚠️ AND IT STAYS `SCOPE_UNIT`. Two FSMs mean two claims on two
|
||||
# actuators, which the allocator consumes as per-unit intervals;
|
||||
# ARCH-01 is explicit that this must never become a site claim,
|
||||
# because per-inverter constraints filed site-wide are the
|
||||
# cross-inverter `lo > hi` contradiction at arbiter.py:114.
|
||||
claims.append(Claim.set("maintenance", P_MAINTENANCE,
|
||||
float(result.setpoint_w or 0.0), result.phase,
|
||||
actuator=self.actuator_of("maintenance", inv)))
|
||||
self.sat_count = 0
|
||||
elif result.charge_only:
|
||||
# Money outranks the maintenance schedule: while the quarter-hour
|
||||
# projection is over the cap, the charge-only shaping is simply not
|
||||
# claimed, so the loop can discharge and shave the peak. When a
|
||||
# dedicated peak-shaving strategy arrives it will claim SET at
|
||||
# P_PEAK and outrank this limit without any code here changing.
|
||||
# ⚠️ AND SAFETY-07 IS THE OTHER HALF OF THIS CONDITION, NOT A
|
||||
# SECOND MECHANISM. The shaping is `hi <= 0`; the peak guard's
|
||||
# claim is `lo >= 0`. Both are limits, arbiter.py applies EVERY
|
||||
# limit at or above the winner's priority, and most restrictive
|
||||
# wins - so a peak event during a maintenance charge window files
|
||||
# `lo > hi`, which is a CONTRADICTION and resolves to 0 W. The
|
||||
# battery would park in the exact quarter it should be shaving.
|
||||
# Priority does not save it: clause 2 has no notion of a
|
||||
# higher-priority limit overriding a lower one, and it should not -
|
||||
# "most restrictive" is what makes the safety bounds unconditional.
|
||||
#
|
||||
# So the higher-priority claimant SUPPRESSES the lower one rather
|
||||
# than out-voting it, which is what this branch already did for
|
||||
# `peak_forecast_entity`. That entity is optional and empty on a
|
||||
# default install, so until now the suspension could not fire on the
|
||||
# site that needed it. `self.peak_guard` is measured from the meter
|
||||
# and is always there.
|
||||
#
|
||||
# ⚠️ THE CONJUNCTION LIVES IN peakguard.py, NOT HERE, and that is
|
||||
# not tidiness. It was inline, and a reviewer mutated it back to its
|
||||
# historical broken form - re-gated on `peak_forecast_entity` alone
|
||||
# - and every suite in this repository stayed green while a default
|
||||
# install parked at 0 W in the quarter that sets the month's bill.
|
||||
# Read shaping_suspended() before touching this: both terms are
|
||||
# there, and why neither is sufficient alone.
|
||||
#
|
||||
# ⚠️ ONE SUSPENSION FLAG FOR THE SITE, NOT ONE PER PACK, AND THE
|
||||
# INTERLOCK IS WHAT MAKES THAT TRUE. The quantity it edge-logs is
|
||||
# a peak event at the grid connection, and `arbitrate()` allows
|
||||
# at most one pack to be in CHARGE at a time, so this branch can
|
||||
# run at most once per tick. Were two packs ever allowed to
|
||||
# charge together, this flag would have to become per-pack - and
|
||||
# so would the reasoning above it.
|
||||
if peakguard.shaping_suspended(
|
||||
self.peak_guard, self.peak_fc,
|
||||
float(self.o.get("peak_cap_w", 3500))):
|
||||
# Edge-logged: level-logging here would write one line per
|
||||
# cycle for as long as the event lasts and flush the 40-line
|
||||
# action log of the very context that explains it.
|
||||
if not self._maint_shape_suspended:
|
||||
self._maint_shape_suspended = True
|
||||
self.log_event("peak at risk - maintenance charge shaping "
|
||||
"suspended so the peak claim is not "
|
||||
"contradicted")
|
||||
else:
|
||||
self._maint_shape_suspended = False
|
||||
hi = 0.0
|
||||
reason = "charge-only"
|
||||
if self.cheap:
|
||||
# ⚠️ CFG-03. `self.maint.cfg.charge_w`, NOT A SECOND READ
|
||||
# OF `self.o`. This line used to re-open the options dict
|
||||
# with its own literal fallback, so the rate the shaping
|
||||
# asked for and the rate the state machine drained at
|
||||
# could be different numbers from the same install - and,
|
||||
# with the key absent, they were. The Controller already
|
||||
# parsed this once in __init__; asking the object that
|
||||
# owns it cannot drift from it. Every pack's machine
|
||||
# holds the same `MaintConfig` instance, so this is the
|
||||
# rate the pack in front of us is charging at.
|
||||
floor = maintenance_charge_floor(
|
||||
self.maint.cfg.charge_w,
|
||||
self.peak_fc, float(self.o.get("peak_cap_w", 3500)))
|
||||
if floor > 0:
|
||||
hi, reason = -floor, "cheap-window charge"
|
||||
# PER-INVERTER, like the SET above and for the same reason -
|
||||
# the shaping is about the pack being charged, which is `inv`.
|
||||
claims.append(Claim.limit("maintenance", P_MAINT_SHAPE, hi=hi,
|
||||
reason=reason,
|
||||
actuator=self.actuator_of("maintenance",
|
||||
inv)))
|
||||
|
||||
# --- the grid-following loop -----------------------------------------
|
||||
if self.auto and self.inputs_ok:
|
||||
@@ -2608,8 +2995,15 @@ class Controller:
|
||||
# here would be a surface to migrate later. This sensor is already
|
||||
# discovered, already on every dashboard, and "failsafe" is
|
||||
# additive to its vocabulary rather than a change to it.
|
||||
# SAFETY-30 adds the site sign latch to the same vocabulary, for
|
||||
# the reason the note above gives: "failsafe" is additive to a
|
||||
# sensor that already exists and is already on every dashboard, and
|
||||
# a P_SAFETY stop that did not reach it would be a site at 0 W
|
||||
# reporting "running".
|
||||
"status": ("failsafe" if any(i.sign_wd.tripped
|
||||
for i in self.inverters)
|
||||
or (self.site_sign_wd.tripped
|
||||
and len(self.inverters) > 1)
|
||||
or self.circ_wd.tripped
|
||||
else "running" if self.auto else "stopped"),
|
||||
# SAFETY-31. ⚠️ MEASURED, not the allocation record - see
|
||||
@@ -2936,24 +3330,70 @@ class Controller:
|
||||
# and a trip on B leaves A commanding. A single row would have to pick
|
||||
# one of them to describe, and the honest answer at a roster of two is
|
||||
# both. At a roster of one the wording is unchanged.
|
||||
# ⚠️ AND SINCE SAFETY-30 THE ROW SAYS WHAT THE UNIT WAS COMPARED
|
||||
# AGAINST, because at a roster of two that is no longer the meter and a
|
||||
# row that still said "the command opposed the meter" would send an
|
||||
# operator to look at P1 for a fault that is visible only on one
|
||||
# inverter's own power sensor. `sign_wd.against` is the same string the
|
||||
# trip sentence uses, so the two cannot drift apart.
|
||||
for inv in self.inverters:
|
||||
tag = "" if len(self.inverters) == 1 else f" [{inv.name}]"
|
||||
# ⚠️ ADDED ONLY WHEN THERE IS SOMETHING TO DISAMBIGUATE. At the
|
||||
# shipped roster of one the two sentences below are the ones that
|
||||
# have always been on the page, word for word - AC 8 is about what
|
||||
# an operator sees as much as about what the detector computes, and
|
||||
# "opposed a meter reading" would be a gratuitous change to a line
|
||||
# somebody has learned to recognise. At N>=2 the noun is load-
|
||||
# bearing: the row would otherwise send them to look at P1 for a
|
||||
# fault that is visible only on one inverter's own power sensor.
|
||||
vs = ("" if len(self.inverters) == 1
|
||||
else f" against {inv.sign_wd.against}")
|
||||
if inv.sign_wd.tripped:
|
||||
what = ("the meter" if len(self.inverters) == 1
|
||||
else inv.sign_wd.against)
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"SIGN-DISAGREEMENT FAILSAFE{tag} - "
|
||||
+ inv.sign_wd.reason
|
||||
+ ". The inverter is held at 0 W. Find out why the "
|
||||
"command opposed the meter before starting control "
|
||||
+ f". The inverter is held at 0 W. Find out why the "
|
||||
f"command opposed {what} before starting control "
|
||||
"again; starting clears this. Restarting the "
|
||||
"add-on does NOT clear it."})
|
||||
else:
|
||||
held = inv.sign_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"sign watchdog{tag}: armed (trips after "
|
||||
"text": f"sign watchdog{tag}: armed{vs} (trips after "
|
||||
f"{inv.sign_wd.cfg.hold_s:.0f} s opposed, both over "
|
||||
f"{inv.sign_wd.cfg.min_w:.0f} W)"
|
||||
+ (f" - opposed for {held:.0f} s now" if held else "")})
|
||||
|
||||
# --- SAFETY-30: the SITE row -----------------------------------------
|
||||
# ⚠️ ONLY AT N>=2, and the absence at N=1 is the honest report rather
|
||||
# than a missing row. With one inverter the site comparison and the row
|
||||
# above are the same sentence about the same actuator; printing it twice
|
||||
# would advertise two guards where there is one, which is how an
|
||||
# operator learns to skim the list.
|
||||
if len(self.inverters) > 1:
|
||||
if self.site_sign_wd.tripped:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "SITE SIGN-DISAGREEMENT FAILSAFE - "
|
||||
+ self.site_sign_wd.reason
|
||||
+ ". EVERY inverter is held at 0 W. This is the "
|
||||
"SUM of the commands against the meter, so it is "
|
||||
"not one inverter's fault to find - look at the "
|
||||
"loop, the integrator and whatever won the "
|
||||
"arbitration. Starting control clears this; "
|
||||
"restarting the add-on does NOT."})
|
||||
else:
|
||||
_sheld = self.site_sign_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"site sign watchdog: armed against the sum of "
|
||||
f"the commands (trips after "
|
||||
f"{self.site_sign_wd.cfg.hold_s:.0f} s opposed, "
|
||||
f"both over "
|
||||
f"{self.site_sign_wd.cfg.min_w:.0f} W)"
|
||||
+ (f" - opposed for {_sheld:.0f} s now"
|
||||
if _sheld else "")})
|
||||
|
||||
# --- SAFETY-31 -----------------------------------------------------
|
||||
# ⚠️ SITE-LEVEL, WHERE THE ROWS ABOVE ARE PER-INVERTER, and the row says
|
||||
# so. There is one circulating figure for the site; naming an inverter
|
||||
@@ -3010,10 +3450,28 @@ class Controller:
|
||||
level, banner = "bad", ("CIRCULATING POWER — the inverters were "
|
||||
"pushing against each other. Site held at "
|
||||
"0 W.")
|
||||
elif self.site_sign_wd.tripped and len(self.inverters) > 1:
|
||||
# SAFETY-30's site half, ABOVE the per-unit rows below and below
|
||||
# circulating power above, and the ordering is the same argument
|
||||
# both times: the banner carries one sentence, so it carries the one
|
||||
# that says the widest true thing. A site sign trip means EVERY
|
||||
# inverter is parked and the fault is in what the site was asking
|
||||
# for, not in one device - naming a unit here would send an operator
|
||||
# to swap the wrong box.
|
||||
level, banner = "bad", ("FAILSAFE — the site's total command "
|
||||
"opposed the meter. Every inverter held at "
|
||||
"0 W.")
|
||||
elif any(i.sign_wd.tripped for i in self.inverters):
|
||||
# Outranks "NOT READY": nothing is missing, something went wrong.
|
||||
level, banner = "bad", ("FAILSAFE — the command opposed the meter. "
|
||||
"Inverter held at 0 W.")
|
||||
# ⚠️ THE SENTENCE IS UNCHANGED AT A ROSTER OF ONE, where "the meter"
|
||||
# is what the unit was graded against. At N>=2 it is that unit's own
|
||||
# power, so the banner says so - see checks() on why the noun is
|
||||
# load-bearing rather than cosmetic.
|
||||
level, banner = "bad", (
|
||||
"FAILSAFE — the command opposed the meter. "
|
||||
"Inverter held at 0 W." if len(self.inverters) == 1 else
|
||||
"FAILSAFE — an inverter's command opposed its own measured "
|
||||
"power. That inverter held at 0 W.")
|
||||
elif bad:
|
||||
# ⚠️ `banner` IF THE ROW OFFERS ONE, `text` OTHERWISE. A row may
|
||||
# need to say more to an operator reading the checks list than fits
|
||||
@@ -3025,14 +3483,29 @@ class Controller:
|
||||
elif not self.auto:
|
||||
level, banner = "warn", "Stopped — inverter commanded to 0 W"
|
||||
elif self.maint.phase != IDLE:
|
||||
# ⚠️ THE PACK IS NAMED ONLY WHEN THERE IS MORE THAN ONE. At a roster
|
||||
# of one this is the string it has always been, character for
|
||||
# character; at two, "Maintenance: drain" without a name is a
|
||||
# banner an operator cannot act on, because the remedy is at one
|
||||
# device and the site has two.
|
||||
level, banner = "warn", f"Maintenance: {self.maint.phase}"
|
||||
if len(self.inverters) > 1:
|
||||
banner += f" ({self.maint_unit.name})"
|
||||
else:
|
||||
level, banner = "ok", "Running — holding grid at zero"
|
||||
|
||||
def w(v):
|
||||
return "—" if v is None else f"{v:,.0f} W".replace(",", " ")
|
||||
|
||||
next_due = self.maint.next_due(datetime.now(timezone.utc))
|
||||
# ⚠️ THE EARLIEST ACROSS THE PACKS, NOT THE FIRST PACK'S. One date on a
|
||||
# site with two schedules has to be the one that comes first, or the row
|
||||
# says "2026-10-01" while a pack recalibrates tomorrow. `None` means
|
||||
# "never run, due now" and has to win over any date, so it is tested for
|
||||
# rather than sorted with. At a roster of one this is that pack's own
|
||||
# date, unchanged.
|
||||
_now = datetime.now(timezone.utc)
|
||||
_dues = [m.next_due(_now) for m in self.maints]
|
||||
next_due = None if any(d is None for d in _dues) else min(_dues)
|
||||
rows = [
|
||||
("Grid", w(self.grid)),
|
||||
("Battery", w(self.site_batt_w)),
|
||||
@@ -3048,7 +3521,14 @@ class Controller:
|
||||
else f"{self.pack_floor_soc:g} %"),
|
||||
("Commanded", w(self.target)),
|
||||
("Why", self.reason),
|
||||
("Maintenance phase", self.maint.phase),
|
||||
("Maintenance phase", self.maint.phase if len(self.inverters) <= 1
|
||||
else f"{self.maint.phase} ({self.maint_unit.name})"),
|
||||
# ⚠️ ONLY WHEN A PACK IS ACTUALLY WAITING, so a one-inverter status
|
||||
# page - where `_maint_deferred` is empty on every tick - carries
|
||||
# exactly the rows it carried before.
|
||||
*((("Maintenance waiting", "; ".join(f"{n}: {why}"
|
||||
for n, why in self._maint_deferred)),)
|
||||
if self._maint_deferred else ()),
|
||||
("Maintenance due", "now" if next_due is None else next_due.strftime("%Y-%m-%d")),
|
||||
("Cheap window", "yes" if self.cheap else "no"),
|
||||
("Tariff", self.tariff_words),
|
||||
@@ -3118,6 +3598,24 @@ class Controller:
|
||||
# unit in particular.
|
||||
self.store.set("sign_tripped", False)
|
||||
self.store.set("sign_reason", "")
|
||||
# SAFETY-30's SITE latch, cleared by the SAME press and for the
|
||||
# same reason the per-unit ones are: the condition always goes
|
||||
# away on its own, because the trip commands 0 W everywhere and
|
||||
# a site commanding zero cannot oppose anything. Only a human
|
||||
# who has read the banner can say the site is clear.
|
||||
#
|
||||
# ⚠️ UNCONDITIONAL, LIKE THE FLAT PAIR ABOVE, AND NOT GUARDED ON
|
||||
# THE ROSTER. An install that ran with two inverters, tripped,
|
||||
# and was then reconfigured back to one would otherwise carry
|
||||
# `site_sign_tripped: true` in its file forever, with no roster
|
||||
# that can reach the code which clears it - and would re-arm the
|
||||
# moment a second inverter was configured again.
|
||||
if self.site_sign_wd.tripped:
|
||||
self.log_event("site sign-disagreement failsafe cleared "
|
||||
"by operator")
|
||||
self.site_sign_wd.reset()
|
||||
self.store.set("site_sign_tripped", False)
|
||||
self.store.set("site_sign_reason", "")
|
||||
# SAFETY-31, cleared by the SAME press and for the same reason:
|
||||
# the condition always goes away on its own, because the trip
|
||||
# commands 0 W everywhere and two inverters at zero cannot
|
||||
@@ -3142,11 +3640,26 @@ class Controller:
|
||||
await self.command_site_zero()
|
||||
return {"auto": self.auto}
|
||||
if what == "maint_start":
|
||||
for msg in self.maint.force_start(now):
|
||||
# ⚠️ WHICH PACK, BECAUSE THERE ARE NOW SEVERAL AND THE BUTTON HAS
|
||||
# ONE LABEL. `_maint_button()` answers it: the pack that holds the
|
||||
# site's maintenance slot if one does - which is what "start"
|
||||
# already meant at a roster of one, where pressing it mid-drain
|
||||
# re-entered DRAIN - and otherwise the pack that has gone longest
|
||||
# without a cycle, which is the same pack `arbitrate()` would have
|
||||
# picked on its own. At N=1 both branches are `maints[0]` and this
|
||||
# is the shipped call, byte for byte.
|
||||
#
|
||||
# A PER-PACK BUTTON IS A UI CARD, NOT THIS ONE. `web.py` posts a
|
||||
# bare `maint_start` with no unit, and inventing a unit parameter
|
||||
# here would ship half a surface: the page would still have one
|
||||
# button and the API would have two meanings.
|
||||
for msg in self._maint_button(now).force_start(now):
|
||||
self.log_event(msg)
|
||||
return {"phase": self.maint.phase}
|
||||
if what == "maint_abort":
|
||||
for msg in self.maint.abort(now, "operator"):
|
||||
# Aborts the pack that is actually cycling - `_maint_button()` again
|
||||
# - and then zeroes the SITE, which is what it always did.
|
||||
for msg in self._maint_button(now).abort(now, "operator"):
|
||||
self.log_event(msg)
|
||||
await self.command_site_zero()
|
||||
return {"phase": self.maint.phase}
|
||||
|
||||
@@ -18,16 +18,47 @@ OWNERSHIP, not priority. Exactly one thing writes the setpoint at any moment:
|
||||
The loop is never "disabled" - it yields. The heartbeat to the inverter keeps
|
||||
running in every phase, so the hardware watchdog stays fed and a crash here
|
||||
still ends with the inverter at 0 W rather than latched.
|
||||
|
||||
ONE PACK AT A TIME (MAINT-05). There is now one `Maintenance` per roster entry,
|
||||
each with its own schedule, its own phase and its own history under its own
|
||||
Store keys - and therefore, for the first time, two of them able to move power
|
||||
on ONE grid connection at once. Read `arbitrate()` before touching any of it:
|
||||
the site holds exactly ONE maintenance slot, a pack that is not IDLE holds it,
|
||||
and every other pack is held at IDLE under the loop until it is released. That
|
||||
is not a scheduling nicety. A drain of pack A against a charge of pack B is two
|
||||
power-moving phases pulling opposite ways across the meter - the circulating
|
||||
power SAFETY-31 exists to DETECT, arriving here as something this module can
|
||||
simply not do.
|
||||
"""
|
||||
|
||||
import logging
|
||||
import math
|
||||
from dataclasses import dataclass, field
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from .store import MAINT_UNIT_KEYS, unit_key
|
||||
|
||||
_LOG = logging.getLogger("goodwe.maint")
|
||||
|
||||
IDLE, DRAIN, CHARGE, HOLD = "idle", "drain", "charge", "hold"
|
||||
|
||||
# ⚠️ THE PHASES THAT MOVE POWER, WHICH IS NOT THE SAME LIST AS "owns the
|
||||
# setpoint". The table above is about WHO WRITES the number; this is about
|
||||
# whether the pack is being pushed. DRAIN and HOLD own the setpoint. CHARGE does
|
||||
# NOT - the loop owns it - and CHARGE is in here anyway, because the charge-only
|
||||
# clamp plus the cheap-window floor is what pulls a second pack full while the
|
||||
# first is being emptied. Leaving CHARGE out is precisely the interlock hole
|
||||
# this card is about: pack A charging from the grid at 2000 W while pack B
|
||||
# drains 2000 W to export is 4 kW going round in a circle with the meter at
|
||||
# zero, and both packs believing they are behaving.
|
||||
#
|
||||
# HOLD commands 0 W and moves nothing, and it is in here for the other half of
|
||||
# the sentence: it OWNS the actuator - the pack is parked at the top for the BMS
|
||||
# and is deliberately not available to the loop - so a second cycle starting
|
||||
# under it would still be two recalibrations at once, which is the thing whose
|
||||
# value is a clean uninterrupted coulomb count.
|
||||
POWER_MOVING = (DRAIN, CHARGE, HOLD)
|
||||
|
||||
# A drain of a 13.8 kWh usable pack (300 Ah x 51.2 V, DoD 90) at the shipped
|
||||
# 2000 W is ~6.9 h even with no house load helping - and less in practice, since
|
||||
# house load drains alongside the export and soc_floor stops short of empty.
|
||||
@@ -153,17 +184,102 @@ class MaintResult:
|
||||
setpoint_w: float | None = None
|
||||
charge_only: bool = False
|
||||
events: list = field(default_factory=list)
|
||||
# ⚠️ WHY A DEFERRAL IS A FIELD AND NOT JUST A LOG LINE. A pack that is due
|
||||
# and is not starting looks, from every surface an operator has, exactly
|
||||
# like a pack whose schedule has quietly stopped firing - §12's opening
|
||||
# sentence, the failure this whole module exists because of. It is carried
|
||||
# so the status page can SAY "waiting for the other pack" rather than
|
||||
# showing an idle machine and a due date in the past. Empty on every path
|
||||
# that is not deferring, so a roster of one never sees it.
|
||||
deferred: str = ""
|
||||
|
||||
|
||||
class UnitHistory:
|
||||
"""One pack's maintenance history in the Store, under one spelling.
|
||||
|
||||
⚠️ THE NAMESPACE IS A CONSTRUCTOR ARGUMENT AND `None` IS A REAL VALUE, NOT
|
||||
AN OMISSION. `unit=None` means the FLAT keys - `phase`, `phase_started`,
|
||||
`last_completed`, `last_start_attempt` - which is what every install has
|
||||
written since the add-on shipped and what a one-inverter site keeps writing
|
||||
after MAINT-05. §6.2's identity: with one pack there is nothing for a
|
||||
namespace to distinguish it FROM, and adding one would change the layout of
|
||||
a live state file to say something it already said. `arbiter.actuator_for()`
|
||||
makes the same move for the same reason and its docstring argues it.
|
||||
|
||||
⚠️ `mirror_flat` IS THE ROLLBACK VIEW AND IT IS ONLY EVER THE FIRST PACK'S.
|
||||
At N>=2 pack A's history has been migrated into its namespace and is written
|
||||
there; the flat keys are ALSO kept in step, so an operator who rolls the
|
||||
add-on back to a single-FSM version finds a CURRENT history rather than one
|
||||
dated the day the second inverter was declared. store.migrate_maint_keys()
|
||||
carries the argument, and it is DEV-02's rule 2 applied to history instead
|
||||
of to a latch: "left in the file" is not the same promise as "still true".
|
||||
Pack B has no flat spelling to mirror to - the flat keys mean pack A on
|
||||
every install that has them - so it is constructed with mirroring off, and
|
||||
a mirror from B would OVERWRITE A's rollback view with B's phase.
|
||||
"""
|
||||
|
||||
def __init__(self, store, unit: str | None = None, mirror_flat: bool = False):
|
||||
self.store = store
|
||||
self.unit = unit
|
||||
self.mirror_flat = bool(mirror_flat)
|
||||
|
||||
def key(self, name: str) -> str:
|
||||
"""The Store key this pack's `name` lives under."""
|
||||
return name if self.unit is None else unit_key(self.unit, name)
|
||||
|
||||
def get(self, name: str, default=None):
|
||||
return getattr(self.store, "data", {}).get(self.key(name), default)
|
||||
|
||||
def set(self, name: str, value) -> None:
|
||||
self.store.set(self.key(name), value)
|
||||
if self.mirror_flat:
|
||||
self.store.set(name, value)
|
||||
|
||||
def get_time(self, name: str):
|
||||
return self.store.get_time(self.key(name))
|
||||
|
||||
def set_time(self, name: str, when) -> None:
|
||||
self.store.set_time(self.key(name), when)
|
||||
if self.mirror_flat:
|
||||
self.store.set_time(name, when)
|
||||
|
||||
|
||||
class Maintenance:
|
||||
def __init__(self, cfg: MaintConfig, store):
|
||||
"""ONE pack's recalibration cycle: its schedule, its phase, its history.
|
||||
|
||||
⚠️ ONE PER ROSTER ENTRY SINCE MAINT-05, AND THE SLOT IS NOT ITS OWN. This
|
||||
object decides WHEN ITS PACK would like to start; `arbitrate()` decides
|
||||
which of them may, because the constraint is a property of the grid
|
||||
connection and no single FSM can see it. Never call `tick()` in a loop
|
||||
without passing the `blocked_by` that `arbitrate()` returned for it: that is
|
||||
the two-packs-at-once bug with the interlock present but not wired.
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: MaintConfig, store, unit: str | None = None,
|
||||
name: str = "", mirror_flat: bool = False):
|
||||
self.cfg = cfg
|
||||
self.store = store
|
||||
# ⚠️ `self.store` IS THE VIEW, NOT THE Store. Everything in this class
|
||||
# names an UNQUALIFIED key - "phase", "last_completed" - and the view is
|
||||
# the one place that turns it into the key this pack owns. A raw
|
||||
# `store.set("phase", ...)` anywhere below would write pack A's history
|
||||
# from pack B's state machine, which is the shared-state bug this card
|
||||
# is about, and there would be nothing to see at a roster of one.
|
||||
self.store = UnitHistory(store, unit, mirror_flat)
|
||||
self.unit = unit
|
||||
# What an event or a refusal calls this pack. At a roster of one it is
|
||||
# never rendered - a single machine cannot be deferred - so the shipped
|
||||
# one-inverter reason strings are untouched.
|
||||
self.name = str(name or unit or "the pack")
|
||||
# Edge-memo for the deferral note. The action log holds 40 lines and a
|
||||
# deferral lasts as long as the other pack's cycle - hours - so a line
|
||||
# per cycle would flush the very context that explains it. Same pattern
|
||||
# as `Controller._arb_action` and `_maint_shape_suspended`.
|
||||
self._deferred = ""
|
||||
|
||||
# -- state ---------------------------------------------------------------
|
||||
@property
|
||||
def phase(self) -> str:
|
||||
return self.store.data.get("phase", IDLE)
|
||||
return self.store.get("phase", IDLE)
|
||||
|
||||
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
|
||||
self.store.set("phase", phase)
|
||||
@@ -185,14 +301,60 @@ class Maintenance:
|
||||
last = self.store.get_time("last_completed")
|
||||
return None if last is None else last + timedelta(days=self.cfg.interval_days)
|
||||
|
||||
def waited_days(self, now: datetime) -> float:
|
||||
"""Days since this pack last COMPLETED a cycle; `inf` if it never has.
|
||||
|
||||
⚠️ THE ARBITRATION KEY, AND IT IS DELIBERATELY NOT `due()`. `due()` is a
|
||||
yes/no and two packs that are both due are indistinguishable by it -
|
||||
which is how a roster-order tie-break gets written and how the first
|
||||
entry then wins every contested month forever while the second drifts.
|
||||
This is an ORDERING: the pack whose coulomb counter has gone longest
|
||||
without a recalibration goes first. `inf` for never-recalibrated is the
|
||||
same statement `due()` makes about an absent `last_completed`, kept as
|
||||
one so a fresh pack cannot lose to one that ran last month.
|
||||
"""
|
||||
last = self.store.get_time("last_completed")
|
||||
return math.inf if last is None else (now - last).total_seconds() / 86400.0
|
||||
|
||||
def _cooled(self, now: datetime) -> bool:
|
||||
"""Is the post-abort cooldown over?"""
|
||||
last_try = self.store.get_time("last_start_attempt")
|
||||
return (last_try is None
|
||||
or (now - last_try) >= timedelta(minutes=RESTART_COOLDOWN_MIN))
|
||||
|
||||
def wants_start(self, now: datetime) -> bool:
|
||||
"""Would this pack begin a cycle on this tick if the site let it?
|
||||
|
||||
⚠️ THE SAME PREDICATE `tick()` USES, NOT A COPY OF IT. `arbitrate()` has
|
||||
to know who is asking before anybody moves, and a second transcription
|
||||
of "enabled, in the start hour, due and cooled down" is a second opinion
|
||||
about who was asking - so the IDLE branch of `tick()` calls this one.
|
||||
"""
|
||||
return (self.phase == IDLE and self.cfg.enabled
|
||||
and now.hour == self.cfg.start_hour and self.due(now)
|
||||
and self._cooled(now))
|
||||
|
||||
# -- operations ----------------------------------------------------------
|
||||
def force_start(self, now: datetime) -> list:
|
||||
def force_start(self, now: datetime, blocked_by: str = "") -> list:
|
||||
"""Start a cycle regardless of the calendar.
|
||||
|
||||
Commissioning uses this: a cycle must be proven end to end before a site
|
||||
is signed off, and nobody waits a month to find out the schedule never
|
||||
fires.
|
||||
|
||||
⚠️ REGARDLESS OF THE CALENDAR, NOT REGARDLESS OF THE INTERLOCK. The
|
||||
calendar is a preference and an operator may overrule it; "one pack
|
||||
moves power at a time" is a property of the grid connection and an
|
||||
operator pressing a button does not add a second one. A forced start
|
||||
against a busy site is REFUSED, by name, and the phase machine does not
|
||||
move - the refusal is returned as an event so the operator reads it in
|
||||
the action log rather than watching nothing happen.
|
||||
"""
|
||||
if blocked_by:
|
||||
msg = (f"maintenance: forced start REFUSED on {self.name} - "
|
||||
f"{blocked_by}")
|
||||
_LOG.warning("%s", msg)
|
||||
return [msg]
|
||||
events = []
|
||||
self.store.set_time("last_start_attempt", now)
|
||||
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
|
||||
@@ -203,23 +365,80 @@ class Maintenance:
|
||||
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
|
||||
return events
|
||||
|
||||
def _defer_note(self, why: str, events: list) -> list:
|
||||
"""Say once, not every second, that this pack is waiting its turn.
|
||||
|
||||
⚠️ THE WORDING IS DELIBERATELY NOT AN ABORT AND NOT A TIMEOUT. §12's
|
||||
notes are explicit that a 12 h phase timeout means "the battery is not
|
||||
following commands - a FAULT, not a slow day", and the one thing that
|
||||
must not happen here is an operator reading a deferral as that. This
|
||||
line says the pack is WAITING, names the pack it is waiting for, and
|
||||
says it will run next - none of which any failure path in this module
|
||||
says.
|
||||
"""
|
||||
if self._deferred != why:
|
||||
self._deferred = why
|
||||
msg = (f"maintenance: {self.name} is due and is WAITING its turn - "
|
||||
f"{why}. It is idle under the control loop and will "
|
||||
f"recalibrate at the next start hour once the slot is free; "
|
||||
f"this is not a stalled phase.")
|
||||
_LOG.info("%s", msg)
|
||||
events.append(msg)
|
||||
return events
|
||||
|
||||
# -- the machine ---------------------------------------------------------
|
||||
def tick(self, now: datetime, soc: float | None) -> MaintResult:
|
||||
def tick(self, now: datetime, soc: float | None,
|
||||
blocked_by: str = "") -> MaintResult:
|
||||
"""One cycle of this pack's state machine.
|
||||
|
||||
`blocked_by` is `arbitrate()`'s answer for THIS pack: empty when the
|
||||
site's one maintenance slot is available to it, otherwise the reason it
|
||||
is not. It gates two things and nothing else - a start, and a phase that
|
||||
is already moving power on a pack that does not hold the slot.
|
||||
"""
|
||||
events: list = []
|
||||
phase = self.phase
|
||||
|
||||
# ⚠️ THE SLOT IS CHECKED BEFORE THE PHASE, AND THIS BRANCH IS A RECOVERY
|
||||
# RATHER THAN AN EXPECTED PATH. `arbitrate()` grants the slot to the
|
||||
# pack that is already mid-cycle, so a pack that is BOTH moving power
|
||||
# and blocked means two histories on disk say "drain" - a hand-edited
|
||||
# state file, or a store carried across a version that had no interlock.
|
||||
# The fail-safe direction is unambiguous: two packs pulling against each
|
||||
# other on one connection is the fault SAFETY-31 latches the whole site
|
||||
# for. Stand this one down to 0 W and say why; the holder keeps its
|
||||
# cycle, which is the outcome that loses no coulomb count at all.
|
||||
if blocked_by and phase in POWER_MOVING:
|
||||
events += self.abort(now, f"interlock - {blocked_by}")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
|
||||
if phase == IDLE:
|
||||
if self.cfg.enabled and now.hour == self.cfg.start_hour and self.due(now):
|
||||
last_try = self.store.get_time("last_start_attempt")
|
||||
cooled = (
|
||||
last_try is None
|
||||
or (now - last_try) >= timedelta(minutes=RESTART_COOLDOWN_MIN)
|
||||
)
|
||||
if cooled:
|
||||
self.store.set_time("last_start_attempt", now)
|
||||
self._enter(DRAIN, now, events,
|
||||
"maintenance: due -> drain (exports the surplus)")
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
if self.wants_start(now):
|
||||
if blocked_by:
|
||||
# ⚠️ `last_start_attempt` IS NOT STAMPED HERE, AND THAT IS
|
||||
# THE STARVATION FIX RATHER THAN AN OMISSION. That key is
|
||||
# the post-ABORT cooldown: it exists so a cycle that failed
|
||||
# does not re-trigger inside the same start hour. A deferral
|
||||
# is not an attempt - nothing was tried and nothing failed -
|
||||
# and stamping it would put this pack under a 90 minute
|
||||
# cooldown for a start hour that is 60 minutes long, so the
|
||||
# pack that lost the arbitration would still be locked out
|
||||
# at the moment the winner released the slot.
|
||||
#
|
||||
# ⚠️ AND THE PHASE DOES NOT MOVE, WHICH IS THE OTHER HALF.
|
||||
# `phase_started` is untouched, so the 12 h DRAIN and 36 h
|
||||
# CHARGE timeouts - which mean "the battery is not following
|
||||
# commands, a fault" - cannot be reached by waiting. A
|
||||
# deferred pack is IDLE under the loop, not a stuck one.
|
||||
return MaintResult(IDLE, False, None, False,
|
||||
self._defer_note(blocked_by, events),
|
||||
blocked_by)
|
||||
self._deferred = ""
|
||||
self.store.set_time("last_start_attempt", now)
|
||||
self._enter(DRAIN, now, events,
|
||||
"maintenance: due -> drain (exports the surplus)")
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
self._deferred = ""
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
|
||||
# ⚠️ Fail toward inaction. Without a state-of-charge reading none of the
|
||||
@@ -273,3 +492,77 @@ class Maintenance:
|
||||
_LOG.error("maintenance: unknown phase %r, forcing idle", phase)
|
||||
events += self.abort(now, f"unknown phase {phase!r}")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
|
||||
|
||||
def _days(n: float) -> str:
|
||||
return "never recalibrated" if n == math.inf else f"{n:.0f} d since its last cycle"
|
||||
|
||||
|
||||
def arbitrate(machines, now: datetime) -> list:
|
||||
"""Grant the site's ONE maintenance slot. Returns a list parallel to
|
||||
`machines`: "" for the pack that may move power, otherwise the reason the
|
||||
pack may not.
|
||||
|
||||
⚠️ THE SLOT IS A PROPERTY OF THE GRID CONNECTION, WHICH IS WHY IT IS NOT ON
|
||||
`Maintenance`. Each FSM can see its own pack's schedule and nothing else; the
|
||||
quantity being rationed - "how many phases are moving power across one
|
||||
meter" - is a sum over the roster, exactly like `sum(|B_i|) - |sum(B_i)|` in
|
||||
SAFETY-31 and for the same reason. A per-pack answer to a site-level
|
||||
question is the shape of defect this repository keeps finding.
|
||||
|
||||
⚠️ IT IS DERIVED, NOT PERSISTED, AND THAT IS DELIBERATE. The holder is
|
||||
"whichever pack's stored phase is not IDLE" - a fact already on disk, in the
|
||||
per-pack history the packs themselves write. A separate `maint_slot_holder`
|
||||
key would be a second opinion about the same thing, and the two would
|
||||
disagree the first time the add-on was killed between writing the phase and
|
||||
writing the holder. Restart-safe by construction: a controller that comes
|
||||
back up mid-drain reads the drain and re-derives the holder from it.
|
||||
|
||||
TWO CLAUSES, IN ORDER:
|
||||
|
||||
1. A PACK ALREADY MOVING POWER KEEPS THE SLOT. Nothing preempts a cycle in
|
||||
flight, because a recalibration interrupted halfway is worth less than
|
||||
nothing - the coulomb counter is graded on ONE uninterrupted drain and
|
||||
refill, so a cycle stopped at 40 % has spent the energy and bought no
|
||||
calibration. If more than one pack somehow comes up moving power, the
|
||||
FIRST in roster order holds and `tick()` stands the others down; see the
|
||||
recovery branch there.
|
||||
|
||||
2. OTHERWISE THE LONGEST-WAITING CANDIDATE STARTS. `wants_start()` is asked
|
||||
of every pack, and among those that say yes the slot goes to the one with
|
||||
the largest `waited_days()`. NOT roster order: two packs on one monthly
|
||||
schedule are due in the same hour every month, and a roster-order tie
|
||||
would hand the slot to `inverters[0]` every single time while the second
|
||||
pack's coulomb counter drifted forever - which is, in a different
|
||||
costume, the exact defect this card was opened for. Roster order breaks a
|
||||
genuine numeric tie and nothing else.
|
||||
|
||||
⚠️ AT A ROSTER OF ONE THIS IS THE IDENTITY FUNCTION. One machine is never
|
||||
another machine's blocker: clause 1 finds at most itself and clause 2 has at
|
||||
most one candidate, so it returns `[""]` on every tick and no reason string
|
||||
it can build is ever rendered. That is what makes the one-inverter behaviour
|
||||
byte-identical rather than merely similar.
|
||||
"""
|
||||
blocks = [""] * len(machines)
|
||||
busy = [(i, m) for i, m in enumerate(machines) if m.phase in POWER_MOVING]
|
||||
if busy:
|
||||
held, holder = busy[0]
|
||||
for i, m in enumerate(machines):
|
||||
if i != held:
|
||||
blocks[i] = (f"{holder.name} is mid-cycle ({holder.phase}) and "
|
||||
f"holds the site's one maintenance slot")
|
||||
return blocks
|
||||
|
||||
wants = [(i, m) for i, m in enumerate(machines) if m.wants_start(now)]
|
||||
if len(wants) <= 1:
|
||||
return blocks
|
||||
# Largest waited_days wins; `-index` makes a numeric tie fall to roster
|
||||
# order rather than to whatever `max()` happens to see first.
|
||||
won, winner = max(wants, key=lambda p: (p[1].waited_days(now), -p[0]))
|
||||
for i, m in wants:
|
||||
if i != won:
|
||||
blocks[i] = (f"{winner.name} has waited longer "
|
||||
f"({_days(winner.waited_days(now))} against "
|
||||
f"{_days(m.waited_days(now))}) and takes the site's "
|
||||
f"one maintenance slot first")
|
||||
return blocks
|
||||
|
||||
+301
-26
@@ -71,6 +71,24 @@ _LOG = logging.getLogger("goodwe.store")
|
||||
# the card is gone while the fault runs on - exactly how the 2026-09-02 outage
|
||||
# went unseen for 6 h 25 m with the detector correct throughout. main.py
|
||||
# re-raises the notification from this key on every start.
|
||||
#
|
||||
# ⚠️ AND SAFETY-30's PAIR IS FLAT FOR THE SAME REASON SAFETY-31's IS, WHICH IS
|
||||
# NOT THE SAME REASON THE ONES ABOVE ARE NAMESPACED. `site_sign_tripped` /
|
||||
# `site_sign_reason` hold the SITE sign-disagreement latch: the SUM of every
|
||||
# standing command opposed the meter, continuously. That is a statement about
|
||||
# the grid connection - the offending number is the site target, which no single
|
||||
# inverter owns - so there is no unit to hang it on, and hanging it on one would
|
||||
# let an operator clear "inverter B's half" of a fault that has no halves.
|
||||
# `unit/<name>/sign_tripped` above stays what it always was and now means what
|
||||
# it says: THAT unit's own command against THAT unit's own measured power.
|
||||
#
|
||||
# ⚠️ AND THEY ARE NOT IN `LEGACY_UNIT_KEYS`, MUST NEVER BE, AND ARE NOT WRITTEN
|
||||
# AT A ROSTER OF ONE AT ALL. At N=1 the site comparison and the unit comparison
|
||||
# are the same sentence and `Controller.cycle()` arms only the per-unit
|
||||
# detector, so a one-inverter install's state file is byte-identical to what it
|
||||
# was before this card - these two keys sit at their defaults and nothing reads
|
||||
# them. A rollback therefore finds exactly the flat `sign_tripped` mirror it
|
||||
# always found.
|
||||
DEFAULTS = {
|
||||
"phase": "idle",
|
||||
"phase_started": None,
|
||||
@@ -80,6 +98,8 @@ DEFAULTS = {
|
||||
"sign_reason": "",
|
||||
"circ_tripped": False,
|
||||
"circ_reason": "",
|
||||
"site_sign_tripped": False,
|
||||
"site_sign_reason": "",
|
||||
}
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
@@ -106,16 +126,53 @@ SCHEMA_VERSION = 1
|
||||
SCHEMA_KEY = "schema_version"
|
||||
|
||||
# Which flat keys belong to ONE inverter, and therefore move into its namespace.
|
||||
# ⚠️ THE MAINTENANCE KEYS ARE NOT IN HERE AND THAT IS DELIBERATE. `phase`,
|
||||
# `phase_started`, `last_completed` and `last_start_attempt` belong to the
|
||||
# maintenance state machine, of which this add-on still holds exactly ONE - a
|
||||
# monthly recalibration is a pack procedure and per-pack SCHEDULING is a card of
|
||||
# its own, not something to infer from a key rename. Moving them here would
|
||||
# quietly re-home an install's whole maintenance history under a unit name; they
|
||||
# stay where they are, untouched, which is the other half of "migrates without
|
||||
# losing its latch OR ITS HISTORY".
|
||||
# ⚠️ THE MAINTENANCE KEYS ARE STILL NOT IN HERE, AND SINCE MAINT-05 THAT IS A
|
||||
# DIFFERENT DECISION RATHER THAN THE SAME ONE. They DO move now - one
|
||||
# `Maintenance` per roster entry needs one history per roster entry - but they
|
||||
# move on their OWN marker, `MAINT_SCHEMA_KEY`, and only on a site that actually
|
||||
# has more than one pack. Two conditions the SAFETY-02 keys do not share, so
|
||||
# folding them into this tuple would either drag them across on a
|
||||
# single-inverter install (which is the byte-identical store layout MAINT-05
|
||||
# must not change) or hold the sign latch hostage to a roster count it has
|
||||
# nothing to do with. `MAINT_UNIT_KEYS` below carries them.
|
||||
LEGACY_UNIT_KEYS = ("sign_tripped", "sign_reason")
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# MAINT-05: THE SECOND MIGRATION, AND WHY IT IS A SECOND ONE
|
||||
#
|
||||
# 0 = the flat, one-history layout every install has had since the add-on
|
||||
# shipped: `phase` / `phase_started` / `last_completed` /
|
||||
# `last_start_attempt` describe THE pack, because there was one FSM.
|
||||
# 1 = one history per roster entry, under `unit/<name>/...`.
|
||||
#
|
||||
# ⚠️ ITS OWN MARKER, NOT A BUMP OF `SCHEMA_VERSION`, AND THE REASON IS THAT THE
|
||||
# TWO MIGRATIONS DO NOT HAVE THE SAME PRECONDITION. DEV-02's runs on every
|
||||
# install exactly once and is monotone in the version number. This one runs ONLY
|
||||
# WHERE THE ROSTER HAS MORE THAN ONE PACK, because at N=1 §6.2's identity holds
|
||||
# and the flat keys ARE that pack's namespace - moving them would add four keys
|
||||
# and a version marker to a store MAINT-05's own acceptance criterion requires
|
||||
# to be byte-identical. A single monotone counter cannot express "migrated on
|
||||
# this site, deliberately not migrated on that one" without lying to the next
|
||||
# version that reads it: a one-inverter store would have to be left at the old
|
||||
# number forever, and then a genuine v2 migration could never be told apart from
|
||||
# a site that simply never grew.
|
||||
#
|
||||
# ⚠️ AND IT IS TWO MARKERS, NOT TWO COPIES OF THE THREE RULES.
|
||||
# `_move_flat_keys()` and `_verify_moves()` below are shared verbatim by both
|
||||
# migrations, so rules 1 and 3 and the READ-BACK POSTCONDITION are one
|
||||
# implementation. A second transcription of a migration is a second opinion
|
||||
# about what "it landed" means.
|
||||
MAINT_SCHEMA_VERSION = 1
|
||||
MAINT_SCHEMA_KEY = "maint_schema_version"
|
||||
|
||||
# The flat maintenance-history keys, in the order they are moved.
|
||||
# ⚠️ THE VALUES ARE THE FLAT SPELLINGS AND THE MODULE THAT READS THEM INDEXES
|
||||
# THIS SAME TUPLE (`maintenance.UnitHistory`), so a key renamed here cannot
|
||||
# silently stop being migrated - the same property `UNIT_STORE_KEYS` gives the
|
||||
# SAFETY-02 pair.
|
||||
MAINT_UNIT_KEYS = ("phase", "phase_started", "last_completed",
|
||||
"last_start_attempt")
|
||||
|
||||
|
||||
def unit_key(unit: str, key: str) -> str:
|
||||
"""The namespaced Store key for `key` on inverter `unit`.
|
||||
@@ -154,16 +211,35 @@ class MigrationReport:
|
||||
# to shout: an alarm that fires on the harmless case is an alarm an
|
||||
# operator learns to dismiss before the real one arrives.
|
||||
self.lost = []
|
||||
# ⚠️ A DIFFERENT FAILURE FROM `lost`, AND IT HAS TO BE, BECAUSE THE
|
||||
# READ-BACK CANNOT SEE IT. `lost` is "the store took the write and
|
||||
# dropped it". This is "the store took the write, kept it perfectly, and
|
||||
# NOTHING WILL EVER READ IT" - the migration was handed a unit name that
|
||||
# is not on the roster, so every machine looks under a different key and
|
||||
# finds nothing. There is no harmless-default version of this the way
|
||||
# there is for `lost`: a write nobody reads is not information, whatever
|
||||
# its value, so anything in here fails `ok` on its own.
|
||||
self.misdirected = []
|
||||
# Why nothing ran, when nothing ran. Empty means "already at schema".
|
||||
self.skipped = ""
|
||||
|
||||
@property
|
||||
def ok(self) -> bool:
|
||||
"""Nothing that CARRIED STATE failed to land."""
|
||||
return not self.lost
|
||||
"""Nothing that CARRIED STATE failed to land, and it landed WHERE THE
|
||||
MACHINES LOOK."""
|
||||
return not self.lost and not self.misdirected
|
||||
|
||||
def explain(self) -> str:
|
||||
if not self.ran:
|
||||
return (f"store already at schema {self.from_version}; no "
|
||||
f"per-inverter migration needed")
|
||||
# ⚠️ `skipped` RATHER THAN A SECOND SENTENCE ABOUT VERSIONS. Since
|
||||
# MAINT-05 there are two reasons a migration does not run - the
|
||||
# store is already at this schema, or the roster has one pack and
|
||||
# the flat keys ARE its namespace - and an operator reading the
|
||||
# startup log needs to be told which, because only one of them
|
||||
# changes when a second inverter is declared.
|
||||
return self.skipped or (f"store already at schema "
|
||||
f"{self.from_version}; no "
|
||||
f"per-inverter migration needed")
|
||||
out = (f"migrated {len(self.moved)} flat key(s) to inverter "
|
||||
f"namespaces: " + ", ".join(sorted(self.moved)))
|
||||
if self.kept:
|
||||
@@ -172,6 +248,8 @@ class MigrationReport:
|
||||
out += " - PROBLEMS: " + "; ".join(self.problems)
|
||||
if self.lost:
|
||||
out += " - STATE LOST: " + "; ".join(self.lost)
|
||||
if self.misdirected:
|
||||
out += " - WRONG NAMESPACE: " + "; ".join(self.misdirected)
|
||||
return out
|
||||
|
||||
|
||||
@@ -223,7 +301,30 @@ def migrate_unit_keys(store, unit: str) -> MigrationReport:
|
||||
return rep
|
||||
|
||||
rep.ran = True
|
||||
for legacy in LEGACY_UNIT_KEYS:
|
||||
_move_flat_keys(store, unit, LEGACY_UNIT_KEYS, rep)
|
||||
_verify_moves(store, rep)
|
||||
|
||||
if rep.ok:
|
||||
store.set(SCHEMA_KEY, SCHEMA_VERSION)
|
||||
else:
|
||||
# ⚠️ NOT MARKED DONE. A migration that lost state must run again on the
|
||||
# next start rather than be recorded as finished - the one thing worse
|
||||
# than a failed migration is a failed migration a later version skips.
|
||||
_LOG.error("per-inverter store migration LOST STATE and has not been "
|
||||
"marked done: %s", rep.explain())
|
||||
return rep
|
||||
|
||||
|
||||
def _move_flat_keys(store, unit: str, keys, rep: MigrationReport) -> None:
|
||||
"""Rule 1, once, for both migrations.
|
||||
|
||||
Copies each flat `key` to `unit/<unit>/<key>` UNLESS the namespaced spelling
|
||||
is already present - a store that has both has been written by a version
|
||||
that knew about the namespace, and that value is the live one. Rule 2 is the
|
||||
absence of a delete: the flat keys are left exactly where they were.
|
||||
"""
|
||||
data = getattr(store, "data", {})
|
||||
for legacy in keys:
|
||||
target = unit_key(unit, legacy)
|
||||
if target in data:
|
||||
rep.kept.append(target)
|
||||
@@ -232,17 +333,63 @@ def migrate_unit_keys(store, unit: str) -> MigrationReport:
|
||||
# tripped has no `sign_tripped` in its file at all, and the value it
|
||||
# then lands on has to be the one `Store.load()` would have supplied -
|
||||
# otherwise "absent" and "never tripped" stop being the same statement,
|
||||
# which is the distinction store.py's own header is about.
|
||||
# which is the distinction store.py's own header is about. The same
|
||||
# sentence holds for `last_completed`: absent means "never recalibrated"
|
||||
# and a literal here would be a second opinion about that.
|
||||
value = data.get(legacy, DEFAULTS.get(legacy))
|
||||
store.set(target, value)
|
||||
rep.moved[target] = value
|
||||
|
||||
# THE POSTCONDITION, AND IT IS A READ-BACK RATHER THAN AN ASSUMPTION. This
|
||||
# is the difference between this function and a two-line copy: the caller
|
||||
# can ask "is the latch that was in the file before now under the key the
|
||||
# watchdog reads", through the same `unit_key()` the watchdog's constructor
|
||||
# reads through, and a `False` there is a guard that is off on an install
|
||||
# whose state file says it is on.
|
||||
|
||||
def _verify_moves(store, rep: MigrationReport, roster=None) -> None:
|
||||
"""THE POSTCONDITION, AND IT IS A READ-BACK RATHER THAN AN ASSUMPTION.
|
||||
|
||||
This is the difference between these functions and a two-line copy: the
|
||||
caller can ask "is the latch that was in the file before now under the key
|
||||
the watchdog reads" - and, since MAINT-05, "is the history that was in the
|
||||
file before now under the key THIS PACK's state machine reads" - through the
|
||||
same `unit_key()` those readers read through. A `False` here is a guard that
|
||||
is off, or a month of coulomb-count history gone, on an install whose state
|
||||
file says otherwise.
|
||||
|
||||
⚠️ AND `roster` IS THE OTHER HALF, WHICH THE READ-BACK ON ITS OWN CANNOT BE.
|
||||
A POSTCONDITION THAT READS BACK THE NAMESPACE IT WAS HANDED CANNOT DETECT
|
||||
BEING HANDED THE WRONG ONE. That is not a hypothetical: MAINT-05 shipped
|
||||
with `migrate_maint_keys()` taking a bare `unit` string, and a call site that
|
||||
passed `inverter.UNIT_A` instead of the first roster entry's name migrated an
|
||||
install's whole maintenance history into `unit/inverter-a/...` on a roster of
|
||||
`["garage", "shed"]`, read all four keys back under that same name, was
|
||||
SATISFIED, and stamped the schema marker - so the next start skipped the
|
||||
migration too and both packs came up believing they had never been
|
||||
recalibrated. Every symptom of a clean migration, and the history gone.
|
||||
`build_roster()` names a declared roster's entries from the config and falls
|
||||
back to a POSITIONAL `inverter-N`, so `inverter-a` is not even the default
|
||||
there; there is no roster on which that write could have been read.
|
||||
|
||||
So the namespace is graded against the one the MACHINES read - the roster -
|
||||
rather than against the argument this function was handed, which is the
|
||||
thing under test. A unit that is not on the roster is `misdirected`, which
|
||||
fails `ok`, which means the caller does NOT stamp the version marker and the
|
||||
next start runs the migration again. A re-run is recoverable, by rule 1; a
|
||||
silent skip is the state store.py's header says must never happen.
|
||||
|
||||
⚠️ AND THE GRADED SET IS `moved` UNION `kept`, WHICH IS WHAT MAKES THAT
|
||||
PARAGRAPH TRUE ON THE SECOND START AS WELL AS THE FIRST. Graded over `moved`
|
||||
alone the refusal lasted exactly one start: the wrong call site is still
|
||||
wrong next time, finds the keys it wrote already present, and rule 1 routes
|
||||
every one of them to `kept` - so `moved` is empty, this loop sees nothing,
|
||||
`ok` comes back True and the marker is stamped on a migration that has
|
||||
reached no readable key. The measurement is in the comment on the loop
|
||||
itself. `test_maintenance.py` section 9c calls this twice with the SAME
|
||||
wrong `unit` over one store, which is the shape nothing in the suite had.
|
||||
|
||||
`roster=None` means "not graded", and the one caller that passes it is
|
||||
`migrate_unit_keys()`, which runs BEFORE `build_roster()` for the reason its
|
||||
own docstring gives - the `Inverter` objects restore their latch in their
|
||||
constructors, so the keys have to be in place before there is a roster to
|
||||
check against. That gap is real and is recorded as a running check rather
|
||||
than left to a comment: see test_maintenance.py section 13.
|
||||
"""
|
||||
for target, value in rep.moved.items():
|
||||
got = getattr(store, "data", {}).get(target, "<<missing>>")
|
||||
if got == value:
|
||||
@@ -254,14 +401,142 @@ def migrate_unit_keys(store, unit: str) -> MigrationReport:
|
||||
if value != DEFAULTS.get(legacy):
|
||||
rep.lost.append(note)
|
||||
|
||||
if roster is None:
|
||||
return
|
||||
names = [str(n) for n in roster]
|
||||
# `unit_key()` builds `unit/<unit>/<key>`, so the unit is field 1. Split
|
||||
# through the same spelling the writer used rather than re-deriving it.
|
||||
#
|
||||
# ⚠️ `moved` UNION `kept`, AND THE UNION IS THE WHOLE OF THE SECOND FIX
|
||||
# ROUND. Grading only `moved` made the refusal last EXACTLY ONE START.
|
||||
# Measured at Controller level over one persisted store, roster
|
||||
# ["garage", "shed"], flat `last_completed` 2026-08-07, with the call site
|
||||
# still handing `inverter-a` on both starts:
|
||||
#
|
||||
# construction 1: ok=False misdirected=4 moved=4 kept=0 marker=<absent>
|
||||
# construction 2: ok=True misdirected=0 moved=0 kept=4 marker=1
|
||||
#
|
||||
# On start 2 the four keys the WRONG start 1 wrote are already present, so
|
||||
# rule 1 routes every one of them to `rep.kept`, `rep.moved` is EMPTY, this
|
||||
# loop iterates over nothing, `misdirected` is empty and `ok` is True - so
|
||||
# the caller stamps the marker and start 3 takes the `from_version >=
|
||||
# SCHEMA` early return FOREVER, including after the call site is fixed.
|
||||
# Loud-and-recoverable became silent-and-permanent after one restart: the
|
||||
# exact state this module's header says must never happen, reached by the
|
||||
# fix that was written to prevent it.
|
||||
#
|
||||
# The union is sound by construction rather than by hope: every entry in
|
||||
# both `rep.moved` and `rep.kept` is a `unit_key(unit, legacy)` built from
|
||||
# the SAME `unit` argument, so grading `kept` grades the same namespace
|
||||
# decision `moved` does. A correct call site puts its `kept` entries under a
|
||||
# roster name and they pass; a wrong one cannot launder its namespace by
|
||||
# having already written it.
|
||||
for target in sorted(set(rep.moved) | set(rep.kept)):
|
||||
parts = target.split("/")
|
||||
unit = parts[1] if len(parts) > 2 else ""
|
||||
if unit in names:
|
||||
continue
|
||||
rep.verified = False
|
||||
note = (f"{target} was migrated into namespace {unit!r}, which is NOT "
|
||||
f"on the roster {names!r} - nothing reads that key")
|
||||
rep.problems.append(note)
|
||||
rep.misdirected.append(note)
|
||||
|
||||
|
||||
def migrate_maint_keys(store, unit: str, roster) -> MigrationReport:
|
||||
"""Move the flat maintenance history into the FIRST pack's namespace.
|
||||
|
||||
MAINT-05. Until this card there was one `Maintenance` and one history, and
|
||||
`store.py`'s own header argued the keys should stay flat because per-pack
|
||||
scheduling was a card of its own. This is that card: there is now one FSM
|
||||
per roster entry, so there is one history per roster entry, and the flat one
|
||||
belongs to the pack that was being recalibrated - `inverters[0]`, which is
|
||||
what `Controller.maint_unit` named and what `validate.py` rule 6 graded
|
||||
against.
|
||||
|
||||
⚠️ `len(roster) <= 1` IS A RETURN, NOT A SPECIAL CASE. At one inverter the
|
||||
flat keys ARE that pack's namespace (§6.2's identity, the same one
|
||||
`arbiter.actuator_for()` leans on), `Maintenance` is constructed to read
|
||||
them directly, and a migration would add four keys plus a marker to a store
|
||||
that must come out byte-identical. The migration happens on the day the
|
||||
roster grows, which is the day the flat spelling stops being able to answer
|
||||
"which pack".
|
||||
|
||||
⚠️ `roster` IS REQUIRED, AND IT REPLACED AN `n_units: int`. Two reasons, and
|
||||
the second is the one MAINT-05 was rejected over.
|
||||
|
||||
The small one: `n_units` was `len(self.inverters)` at the only call site, so
|
||||
the roster carries it - `len(roster)` - and a count passed beside the names
|
||||
is a second opinion about how many packs there are.
|
||||
|
||||
The load-bearing one: THE NAMES ARE THE POSTCONDITION. `unit` says which
|
||||
pack the flat keys belonged to and that is genuinely a decision - the first
|
||||
roster entry, because that is the pack the one FSM was driving - but a
|
||||
decision the caller can get WRONG, and until this signature existed nothing
|
||||
could tell. `_verify_moves()` read back the namespace it was handed, so a
|
||||
migration into a name no machine reads verified clean and stamped the
|
||||
marker. Handing the roster in means the read-back is graded against the
|
||||
keys the MACHINES read, and a `unit` that is not among these names comes
|
||||
back `misdirected`: not `ok`, marker NOT written, migration runs again next
|
||||
start - and again the start after that, because `_verify_moves()` grades
|
||||
`kept` as well as `moved`. See `_verify_moves()` for the install this was
|
||||
measured on, and for what grading `moved` alone cost on start 2.
|
||||
|
||||
THE THREE RULES ARE `migrate_unit_keys()`'s, SHARED IN CODE rather than
|
||||
restated: `_move_flat_keys()` is rule 1 (never overwrite a namespaced value)
|
||||
and rule 2 (the flat keys are left in the file), `_verify_moves()` is the
|
||||
read-back postcondition, and the marker is written LAST so a crash before it
|
||||
leaves the migration to run again - which rule 1 makes a no-op.
|
||||
|
||||
⚠️ AND RULE 2 IS KEPT LIVE HERE TOO, WHICH IS THE HALF DEV-02 HAD TO ADD
|
||||
LATER. "Left in place" alone makes the flat history a fossil dated the day
|
||||
the second inverter was declared: an operator who rolls back to a
|
||||
single-FSM add-on would find a `last_completed` months old and recalibrate a
|
||||
pack that does not need it, or - worse - a stale `phase` and a
|
||||
`phase_started` old enough to abort on the 12 h timeout the moment it comes
|
||||
up. So `maintenance.UnitHistory` MIRRORS the first pack's writes back onto
|
||||
the flat keys for as long as the roster has more than one entry. The flat
|
||||
pair is the ROLLBACK VIEW of the history, maintained, exactly as
|
||||
`sign_tripped` is the rollback view of the latch.
|
||||
"""
|
||||
rep = MigrationReport()
|
||||
data = getattr(store, "data", {})
|
||||
names = [str(n) for n in roster]
|
||||
rep.from_version = int(data.get(MAINT_SCHEMA_KEY, 0) or 0)
|
||||
if len(names) <= 1:
|
||||
rep.skipped = ("one inverter: the flat maintenance keys ARE that pack's "
|
||||
"history and are read in place, so there is nothing to "
|
||||
"move and the store layout does not change")
|
||||
return rep
|
||||
if rep.from_version >= MAINT_SCHEMA_VERSION:
|
||||
rep.skipped = (f"maintenance history already at schema "
|
||||
f"{rep.from_version}; written by a multi-inverter "
|
||||
f"version and not touched")
|
||||
return rep
|
||||
|
||||
rep.ran = True
|
||||
_move_flat_keys(store, unit, MAINT_UNIT_KEYS, rep)
|
||||
_verify_moves(store, rep, roster=names)
|
||||
|
||||
# ⚠️ `rep.ok` AND NOTHING ELSE - NOT `ok or kept`, NOT `not lost`, NOT
|
||||
# `not misdirected`. BOTH guards gate this line and each one is pinned by a
|
||||
# check that the other cannot satisfy: section 9c refuses a store whose
|
||||
# failure is `misdirected` with `lost` empty, and section 9d refuses one
|
||||
# whose failure is `lost` with `misdirected` empty AND `kept` non-empty -
|
||||
# the mutation `if rep.ok or rep.kept:` stamps the marker on a migration
|
||||
# that lost a month of history, and until section 9d existed all 19 suites
|
||||
# were green on it.
|
||||
if rep.ok:
|
||||
store.set(SCHEMA_KEY, SCHEMA_VERSION)
|
||||
store.set(MAINT_SCHEMA_KEY, MAINT_SCHEMA_VERSION)
|
||||
else:
|
||||
# ⚠️ NOT MARKED DONE. A migration that lost state must run again on the
|
||||
# next start rather than be recorded as finished - the one thing worse
|
||||
# than a failed migration is a failed migration a later version skips.
|
||||
_LOG.error("per-inverter store migration LOST STATE and has not been "
|
||||
"marked done: %s", rep.explain())
|
||||
# ⚠️ NOT MARKED DONE, FOR EITHER FAILURE. The same sentence
|
||||
# `migrate_unit_keys()` carries: the one thing worse than a failed
|
||||
# migration is a failed migration a later version skips. Rule 1 makes
|
||||
# the re-run a no-op where the keys did land, so refusing the marker
|
||||
# costs one repeated pass and buys the difference between a migration
|
||||
# that can still be fixed and one the store says already happened.
|
||||
_LOG.error("per-pack maintenance-history migration did NOT land and "
|
||||
"has not been marked done: %s", rep.explain())
|
||||
return rep
|
||||
|
||||
|
||||
|
||||
@@ -74,7 +74,8 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
was overruled. That firmware file's own comment says a lower bound on this
|
||||
"belongs in CFG-01, not here" - so here it is.
|
||||
|
||||
5. `sign_disagree_w` at or above `max_w`. [(a)]
|
||||
5. `sign_disagree_w` - or SAFETY-30's `unit_sign_disagree_w` - at or above
|
||||
`max_w`. [(a)]
|
||||
The arbiter's `supervised` limit bounds every command to +-max_w, and
|
||||
SAFETY-02's predicate needs `abs(command) > sign_disagree_w`. Set the
|
||||
threshold at or above the ceiling and the command side of the comparison
|
||||
@@ -234,6 +235,7 @@ from .p1 import is_enabled, validate_meter_options
|
||||
from .peakguard import PEAK_OPTION_DEFAULTS
|
||||
from .price import PRICE_OPTION_DEFAULTS, PROVIDERS
|
||||
from .static_tariff import ProfileInvalid, parse_static_profile
|
||||
from .watchdog import SIGN_OPTION_DEFAULTS
|
||||
|
||||
_LOG = logging.getLogger("goodwe.config")
|
||||
|
||||
@@ -741,6 +743,38 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
f"sign_disagree_w below {weakest:.0f} W (300 W is the measured "
|
||||
"default), or raise max_w.")
|
||||
|
||||
# ⚠️ AND THE SAME RULE FOR SAFETY-30's PER-UNIT THRESHOLD, WHICH IS A
|
||||
# SEPARATE COMPARISON AND THEREFORE A SEPARATE WAY TO DISARM. It grades a
|
||||
# unit's own SHARE against that unit's own measured power, and a share is
|
||||
# bounded by the same `supervised` claim at +-max_w - so a threshold at or
|
||||
# above the ceiling makes the command side unsatisfiable by construction,
|
||||
# exactly as above. Written as its own branch rather than folded into the
|
||||
# one above because the two produce different sentences and an operator
|
||||
# needs to be told WHICH watchdog they have disarmed.
|
||||
#
|
||||
# ⚠️ REFUSED EVEN AT A ROSTER OF ONE, WHERE THIS CHECK IS NOT ARMED. A
|
||||
# config that cannot work is refused when it is WRITTEN, not on the day a
|
||||
# second inverter is added - which is the day nobody is watching the startup
|
||||
# log. This is `meter_max_age_s`'s rule read the same way: the failure it
|
||||
# prevents is silent.
|
||||
unit_sign_w = _number(opts, "unit_sign_disagree_w",
|
||||
float(SIGN_OPTION_DEFAULTS["unit_sign_disagree_w"]))
|
||||
if unit_sign_w is None:
|
||||
problems.append(f"unit_sign_disagree_w "
|
||||
f"{opts.get('unit_sign_disagree_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and unit_sign_w >= max_w:
|
||||
problems.append(
|
||||
f"unit_sign_disagree_w is {unit_sign_w:.0f} W but max_w is "
|
||||
f"{max_w:.0f} W, so the SAFETY-30 per-inverter sign-disagreement "
|
||||
"watchdog can never fire: no inverter is ever commanded past max_w, "
|
||||
f"and the watchdog needs a command over {unit_sign_w:.0f} W. At two "
|
||||
"inverters that is the guard which catches a unit doing the "
|
||||
"OPPOSITE of what it was told while its sibling covers for it at "
|
||||
"the meter - the case the site-level watchdog is structurally "
|
||||
f"blind to. Lower unit_sign_disagree_w below {max_w:.0f} W "
|
||||
f"({SIGN_OPTION_DEFAULTS['unit_sign_disagree_w']:.0f} W is the "
|
||||
"measured default), or raise max_w.")
|
||||
|
||||
# --- 6. a maintenance charge the ceiling can actually accommodate --------
|
||||
# ⚠️ Strictly `>`, matching the arbiter exactly. The shaping is
|
||||
# `Claim.limit(hi=-charge_w)` against `supervised`'s `lo=-max_w`, so
|
||||
@@ -768,24 +802,47 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
# rule 8 below already makes with `PEAK_OPTION_DEFAULTS` - and
|
||||
# test_maintenance.py pins it by reading the shipped file.
|
||||
#
|
||||
# ⚠️ AND IT IS GRADED AGAINST THE FIRST UNIT'S CAP, NOT THE SMALLEST AND NOT
|
||||
# THE FLAT ONE. Rule 5 takes the weakest unit because there is a watchdog on
|
||||
# every one of them; there is exactly ONE `Maintenance` in this add-on and
|
||||
# `Controller.maint_unit` names the pack it recalibrates - the first in the
|
||||
# roster, because the cycle's history lives under un-namespaced Store keys.
|
||||
# The shaping claim is filed on THAT actuator and on no other, so the cap
|
||||
# that can contradict it is THAT unit's. Taking `min()` here would refuse a
|
||||
# perfectly workable site - a 5000 W pack being recalibrated beside a 2000 W
|
||||
# sibling the cycle never touches - which is the over-refusal this file's
|
||||
# docstring says gets a validator switched off. When `maint_unit` stops
|
||||
# being `inverters[0]`, this line moves with it.
|
||||
# ⚠️ MAINT-05: IT IS GRADED AGAINST THE WEAKEST UNIT'S CAP NOW, AND THE
|
||||
# COMMENT THIS REPLACES SAID SO WOULD HAPPEN. It read: "there is exactly ONE
|
||||
# `Maintenance` in this add-on and `Controller.maint_unit` names the pack it
|
||||
# recalibrates - the first in the roster, because the cycle's history lives
|
||||
# under un-namespaced Store keys. The shaping claim is filed on THAT
|
||||
# actuator and on no other, so the cap that can contradict it is THAT
|
||||
# unit's. Taking `min()` here would refuse a perfectly workable site - a
|
||||
# 5000 W pack being recalibrated beside a 2000 W sibling the cycle never
|
||||
# touches ... When `maint_unit` stops being `inverters[0]`, this line moves
|
||||
# with it."
|
||||
#
|
||||
# `maint_unit` has stopped being `inverters[0]`. There is one `Maintenance`
|
||||
# per roster entry, each with its own namespaced history, and EVERY pack is
|
||||
# recalibrated on its own schedule - so the sibling "the cycle never
|
||||
# touches" does not exist any more and the over-refusal argument has no
|
||||
# subject. The shaping claim is filed on whichever pack is charging, so the
|
||||
# cap that can contradict it is any cap on the roster, and the one that
|
||||
# contradicts it FIRST is the smallest. This is rule 5's conjunction for
|
||||
# rule 5's reason: a threshold that is fine against the biggest unit says
|
||||
# nothing about the smallest, and the smallest is the one that goes to 0 W.
|
||||
#
|
||||
# ⚠️ THIS REFUSES CONFIGS THAT USED TO START, AND THAT IS THE POINT RATHER
|
||||
# THAN A SIDE EFFECT. `max_w` 5000 on pack A beside 2000 on pack B with
|
||||
# `maintenance_charge_w` 3000 was accepted before this card and was correct
|
||||
# while only pack A was ever recalibrated. Pack B now recalibrates too, and
|
||||
# its cheap-window charge asks the arbiter for `hi = -3000` against a
|
||||
# supervised `lo = -2000`: `lo > hi`, arbiter clause 3, 0 W, contradiction -
|
||||
# a maintenance charge that silently never happens on that pack, which is
|
||||
# exactly what rule 6 exists to refuse at the moment it is WRITTEN. At a
|
||||
# roster of one `min()` over one cap is that cap and the comparison, the
|
||||
# message and the boundary are identical.
|
||||
charge_w = _number(opts, "maintenance_charge_w",
|
||||
float(MAINT_OPTION_DEFAULTS["maintenance_charge_w"]))
|
||||
# ⚠️ THE SAME PAIRING AS RULE 5, FOR THE SAME REASON. `caps[0]` is the first
|
||||
# unit WITH A USABLE CAP, which is `inverters[0]` only while every earlier
|
||||
# entry has one; `_unit_label(opts, 0)` was hard-wired to `inverters[0]`
|
||||
# regardless. Both come off the one pair now.
|
||||
maint_index, maint_cap = caps_ix[0] if caps_ix else (0, None)
|
||||
# ⚠️ THE SAME PAIRING AS RULE 5, FOR THE SAME REASON: `unit_caps_indexed()`
|
||||
# SKIPS entries with no usable `max_w`, so a caps-list position is not a
|
||||
# roster position and `_unit_label()` indexes the roster. The index travels
|
||||
# with the number, so the unit the message names is the unit the number came
|
||||
# off - which on a roster whose first entry has a junk `max_w` is not the
|
||||
# same thing at all.
|
||||
maint_index, maint_cap = (min(caps_ix, key=lambda p: p[1]) if caps_ix
|
||||
else (0, None))
|
||||
maint_where = _unit_label(opts, maint_index)
|
||||
if charge_w is None:
|
||||
problems.append(
|
||||
|
||||
@@ -164,11 +164,106 @@ saturation freeze's question (|command - the battery's actual power| > 500 W,
|
||||
NOTES.md §4.7 row 4), and the two checks are complementary rather than
|
||||
overlapping. Neither substitutes for the other.
|
||||
|
||||
⚠️ THAT PARAGRAPH IS ABOUT THE COMMAND-VERSUS-METER COMPARISON, AND SINCE
|
||||
SAFETY-30 THAT IS NOT THE ONLY ONE THIS MODULE DRIVES. At a roster of two or
|
||||
more each unit is ALSO graded against its own measured power, which is exactly
|
||||
the comparison the paragraph says nothing here makes - see the SAFETY-30 section
|
||||
below, which says what that does and does not take away from the freeze. At the
|
||||
shipped roster of one the paragraph stands unchanged, word for word: the site
|
||||
comparison is the only detector armed and the freeze is still the whole answer.
|
||||
|
||||
Nor does it see a sign inversion introduced DOWNSTREAM of this add-on - in the
|
||||
firmware, on the wire, or in a future driver. Our view stays self-consistent and
|
||||
this stays silent. That is a wire-versus-intent problem and it belongs to the
|
||||
witness, which is the only vantage point that sees both.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
SAFETY-30 - AT TWO INVERTERS THIS IS TWO QUESTIONS, NOT ONE
|
||||
|
||||
Everything above was written at a roster of ONE, and at N=1 it is right for a
|
||||
reason that stops being true at N=2. `commanded_w` is what THIS controller put
|
||||
on THIS actuator. `grid_w` is what the WHOLE SITE is exchanging with the
|
||||
network. At one inverter those are two views of one thing - §6.2's identity -
|
||||
which is what makes comparing them sound. At two they are not:
|
||||
|
||||
* A FALSE TRIP THE COMPARISON CANNOT AVOID. "Inverter A commanded -1500 W
|
||||
while the meter reads +1500 W" is evidence of nothing at N=2: inverter B may
|
||||
be discharging 3000 W and doing exactly what it was told. No fault anywhere,
|
||||
and the check NOTES.md calls the highest-value entry in the safety table -
|
||||
93 % agreement while healthy against 4 % during runaway, four episodes, zero
|
||||
false positives - fires.
|
||||
* THE CONVERSE, WHICH IS WORSE. A unit genuinely driving the wrong way is
|
||||
MASKED, because the site figure NETS. Commanded +1500 W, measured -1500 W,
|
||||
beside a sibling measured at +1500 W: the meter sits exactly where a healthy
|
||||
site leaves it. This is not a threshold that is set too high - the
|
||||
information is destroyed by the summation, and no tuning recovers it.
|
||||
|
||||
So the one comparison becomes two, each asked of the evidence that can answer
|
||||
it, and they are DIFFERENT FAULTS rather than one fault at two scales:
|
||||
|
||||
PER UNIT this unit's standing command against ITS OWN measured power -
|
||||
`Inverter.batt`, which on the live system is holding register
|
||||
0x0518, this inverter's own AC power, per-instance since DEV-02.
|
||||
Conclusion: "THE ACTUATOR I AM DRIVING IS NOT DOING WHAT I TOLD
|
||||
IT". The evidence is about one unit, so the remedy is that unit:
|
||||
the `failsafe` SET, which arbiter.CLAIM_SCOPE has called a UNIT
|
||||
claim from the day it was written, for this exact reason.
|
||||
SITE the SUM of the standing commands against the meter. Conclusion:
|
||||
"THE SITE AS A WHOLE IS DRIVING THE WRONG WAY" - an inverted gain,
|
||||
an integrator wound past the rail, a strategy pushing the wrong
|
||||
side of the meter. That is the fault the 2026-08-20 capture
|
||||
contains and it is a property of the CONNECTION, so the remedy is
|
||||
the connection: a SITE SET that stops every inverter.
|
||||
|
||||
⚠️ AND AT N=1 THERE IS EXACTLY ONE ARMED DETECTOR, WHICH IS THE ONE THAT
|
||||
SHIPPED. The two questions above are the SAME SENTENCE at a roster of one: the
|
||||
sum of one command is that command, and "the site" and "the unit" name one
|
||||
actuator. Arming both would be arming a duplicate - two latches, two banners and
|
||||
two chances to spend a false-positive record that was earned by ONE comparison
|
||||
on two captured bus days. `Controller.cycle()` therefore hands the single unit's
|
||||
watchdog THE METER, under the shipped `sign_disagree_w` / `sign_disagree_s`,
|
||||
exactly as before, and never arms the site one. `arm()` below is where that
|
||||
choice is written down. Nothing about a one-inverter install changes - not the
|
||||
comparison, not the thresholds, not the store keys, not the claim, not the
|
||||
banner.
|
||||
|
||||
⚠️ WHAT THE PER-UNIT COMPARISON IS NOT. Two guards that overlap without saying
|
||||
so is how a false-alarm generator gets built, so both neighbours are named:
|
||||
|
||||
* IT IS NOT SAFETY-31. `circulation.py` compares the units AGAINST EACH OTHER
|
||||
- `sum(|B_i|) - |sum(B_i)|` over MEASURED power - and catches two inverters
|
||||
pushing THROUGH each other, which nets to zero at the meter and about which
|
||||
no single command is evidence at all. This compares each unit against ITS
|
||||
OWN COMMAND. Take two units faithfully executing an allocation that ALLOC-01
|
||||
would refuse: circulating power is the whole loop, and every per-unit sign
|
||||
check here reads perfect agreement. Take one unit doing the exact opposite
|
||||
of its share while its sibling covers for it: this reads the whole
|
||||
disagreement, and circulating power can be zero, because the two measured
|
||||
powers may well agree in sign. Neither is the other with a different
|
||||
threshold.
|
||||
* IT IS NOT THE SATURATION FREEZE, AND THE OVERLAP IS REAL AND BOUNDED. The
|
||||
freeze asks `|command - measured| > saturation_w` (500 W) and concludes "the
|
||||
inverter cannot follow"; it then stops the integrator winding, which is a
|
||||
control action taken every day, on a unit that is merely SATURATED as
|
||||
readily as on one that is reversed, and it neither latches nor parks
|
||||
anything. This asks for OPPOSITION - a sign, on both sides of a threshold,
|
||||
held continuously - which a saturated-but-obedient unit cannot produce at
|
||||
all, and it LATCHES and commands that unit to zero. The freeze is a
|
||||
magnitude test that shapes the loop; this is a direction test that stops an
|
||||
actuator.
|
||||
|
||||
⚠️ GATE 1 STILL APPLIES TO BOTH, AND THAT IS A DELIBERATE CHOICE WITH A COST.
|
||||
The per-unit comparison could have been armed whenever ANY non-zero command is
|
||||
standing - a unit should do what it is told whoever told it - and that would
|
||||
catch a wedged inverter during a maintenance charge. It is not, because the
|
||||
whole no-false-positive argument above is built on `following`, because the
|
||||
freeze already grades that window, and because this card's own warning is that
|
||||
SAFETY-02's record was earned at N=1 and must not be spent on a check that fires
|
||||
when nothing is wrong. What it costs is written here rather than discovered:
|
||||
between the start of a maintenance cycle and its end, a unit reversing against
|
||||
its own command is the freeze's to notice, not this module's. Widening it is a
|
||||
card, with a rig campaign behind it, not an edit.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
STATE, TRIP AND LATCH
|
||||
|
||||
@@ -198,6 +293,178 @@ from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
|
||||
# SAFETY-30. CFG-03: THE ONE IN-CODE COPY OF THE FOUR MULTI-INVERTER DEFAULTS.
|
||||
# `config.yaml`'s `options:` block is the source of truth an operator edits and
|
||||
# the Supervisor reads, and `schema:` holds the bounds. This dict exists for the
|
||||
# reason `circulation.CIRC_OPTION_DEFAULTS` and `maintenance.MAINT_OPTION_DEFAULTS`
|
||||
# do - the Dockerfile does not put config.yaml in the image, so the running
|
||||
# add-on cannot read it - and `test_watchdog.py` pins the two together by READING
|
||||
# config.yaml, so a drift goes red in CI rather than shipping.
|
||||
#
|
||||
# ⚠️ EVERY KEY HERE IS DEAD AT A ROSTER OF ONE, and that is the point rather
|
||||
# than a caveat. `Controller._arm_sign_watchdogs()` arms the single unit's
|
||||
# detector against the meter with the SHIPPED `sign_disagree_w` /
|
||||
# `sign_disagree_s`, which are read in main.py exactly where they always were
|
||||
# and are not in this dict. Nothing below is consulted until a second inverter
|
||||
# exists.
|
||||
SIGN_OPTION_DEFAULTS = {
|
||||
# --- THE MAGNITUDE GATE, AND IT IS NOT SAFETY-02's 300 W BY ACCIDENT ---
|
||||
# ⚠️ DERIVED FROM `control.Tuning.saturation_w`, WHICH IS 500 W, AND THE
|
||||
# DERIVATION IS THE POINT. This check gates on BOTH sides being over
|
||||
# `min_w`, so the smallest divergence it can ever see between a command and
|
||||
# the power that command produced is `2 * min_w` - the two are OPPOSED, so
|
||||
# the gap is the sum of the magnitudes. At 250 W that is exactly 500 W: the
|
||||
# gap at which `compute()`'s own anti-windup test already concludes THE
|
||||
# INVERTER IS NOT FOLLOWING and freezes the integrator. So this watchdog
|
||||
# cannot fire on a divergence the shipped control law itself calls ordinary
|
||||
# tracking, and the two guards meet at a number rather than overlapping in a
|
||||
# band nobody has drawn.
|
||||
#
|
||||
# MEASURED, on 1890 closed-loop two-inverter runs in which NOTHING is faulty
|
||||
# (every unit executes the share the allocator gave it), swept over the
|
||||
# WHOLE range config.yaml accepts for `gain` float(0.05,1.0) and `slew_w`
|
||||
# int(50,5000), across both families of stimulus that can produce legitimate
|
||||
# opposition. Worst CONTINUOUS opposition between a unit's standing command
|
||||
# and its own 0x0518 power, as a function of this threshold:
|
||||
#
|
||||
# 50 W -> 25.0 s 250 W -> 10.0 s 700 W -> 5.0 s
|
||||
# 150 W -> 15.0 s 300 W -> 10.0 s 1000 W -> 0.0 s
|
||||
# 200 W -> 15.0 s 500 W -> 5.0 s
|
||||
#
|
||||
# ⚠️ AND THE CURVE IS FLAT, WHICH IS THE FINDING THAT DECIDED THE SHAPE OF
|
||||
# THIS PAIR. Unlike the site comparison - where the meter is driven by the
|
||||
# LOAD and a flapping load holds it opposed for minutes - a unit's own power
|
||||
# CHASES ITS OWN COMMAND through a bounded ramp and a first-order lag, so the
|
||||
# opposition can only last as long as the crossing does. Dropping the
|
||||
# threshold from 300 W to 50 W buys 15 s of extra transient and nothing else.
|
||||
# The work is therefore done by the WINDOW below, and this number is set
|
||||
# where the control law already draws its line rather than being tuned.
|
||||
#
|
||||
# The largest opposed magnitude seen anywhere in those 1890 runs is 875 W;
|
||||
# a threshold above that would gate NOTHING legitimate in at all, and is
|
||||
# rejected because it would also be blind to a unit reversing a 900 W share.
|
||||
"unit_sign_disagree_w": 250,
|
||||
|
||||
# --- THE WINDOW -------------------------------------------------------
|
||||
# Three bounds, and the value clears all three.
|
||||
#
|
||||
# LOWER, from the rig: 10.0 s - two control cycles, the worst CONTINUOUS
|
||||
# legitimate opposition above 250 W across all 1890 runs. It is a
|
||||
# reversing site whose second write lands a cycle after the first, both
|
||||
# units then slewing through zero behind a 10 s lag; nothing is wrong.
|
||||
#
|
||||
# LOWER, from the firmware: `inverter.LINK_STALE_S`, 30 s. A unit not
|
||||
# executing its share for less than the firmware's own veto window is a
|
||||
# LINK fault, and the add-on already answers it - liveness drops the unit
|
||||
# and the survivors carry its share, with the record saying so. Firing
|
||||
# inside that window would raise a second, louder alarm about a state
|
||||
# already being handled, which is the SAFETY-15/SAFETY-19 failure exactly.
|
||||
#
|
||||
# UPPER, from SAFETY-02 itself: 180 s, the SITE hold. A unit that is not
|
||||
# doing what it was told must not be parked LATER than the site would be
|
||||
# parked for the same watts, and unlike the site comparison this one needs
|
||||
# nothing to net out before it can conclude - the evidence is complete on
|
||||
# the first cycle it appears.
|
||||
#
|
||||
# 85 s: seventeen control cycles - 8.5x the worst legitimate episode this
|
||||
# rig can produce, 2.8x the firmware's own veto window, and under HALF the
|
||||
# site hold. ⚠️ IT IS DELIBERATELY NOT 60, 75, 90, 120 OR 180. A round
|
||||
# number here would be a guess wearing a measurement's clothes, and the
|
||||
# three bounds above are what the number has to answer to.
|
||||
#
|
||||
# ⚠️ AND INVERTER B DOES NOT PHYSICALLY EXIST. Its ramp and lag in the rig
|
||||
# are inverter A's, COPIED, carrying `measured=False` - SPIKE-04 measures
|
||||
# the real ones. A slower second unit lengthens every crossing above, which
|
||||
# is what the 8.5x buys headroom for. SPIKE-04 is the revisit trigger for
|
||||
# both numbers here, not a reason to move them now.
|
||||
"unit_sign_disagree_s": 85,
|
||||
|
||||
# --- THE SITE COMPARISON AT N>=2, AND IT IS NOT THE SHIPPED PAIR -------
|
||||
# ⚠️ THE THRESHOLD IS CARRIED AND THE WINDOW IS NOT, WHICH IS A FINDING
|
||||
# RATHER THAN A COMPROMISE. Only one of the two arguments behind 300 W /
|
||||
# 180 s depends on how many inverters the site has:
|
||||
#
|
||||
# THE THRESHOLD is about NOISE. "Near zero the sign is noise, and near
|
||||
# zero is where a healthy loop LIVES" - the deadband holds the command
|
||||
# still while the meter wanders either side of `target_grid_w`. The
|
||||
# deadband is 15 W and P1 is one meter whatever the roster, so nothing
|
||||
# about that argument moves. 300 W, carried - and the two-inverter
|
||||
# campaign says the carry is safe rather than merely convenient: in the
|
||||
# load-reversal family the site figure ever goes opposed AND over 300 W in
|
||||
# 994 of 1050 runs at two inverters and 955 of 1050 at one. The gate opens
|
||||
# about as often either way; what changed is how LONG it stays open, which
|
||||
# is the window's problem and not the threshold's.
|
||||
#
|
||||
# THE WINDOW is about a TRANSIENT, and the transient scales with the site.
|
||||
# The measured worst legitimate case is a load reversal that the loop
|
||||
# crosses zero slowly: the command has to travel the whole rail at
|
||||
# `slew_w` per cycle, and at N>=2 the rail is `Controller.site_max_w` - the
|
||||
# ROSTER SUM - while `slew_w` is unchanged. So the crossing takes about
|
||||
# twice as long at two inverters as at one, and that is exactly what the
|
||||
# rig measures.
|
||||
#
|
||||
# 1890 closed-loop runs in which nothing is faulty, the SAME campaign the
|
||||
# per-unit pair above is read off, run at BOTH rosters as its own control.
|
||||
# Worst CONTINUOUS opposition between the standing command(s) and the meter,
|
||||
# LOAD-REVERSAL family, at a 300 W threshold:
|
||||
#
|
||||
# N=1 (the shipped comparison) 110.0 s - inside 180 s, 1.6x
|
||||
# N=2 (the sum, same stimuli) 215.0 s - OVER 180 s
|
||||
#
|
||||
# ⚠️ SO CARRYING 180 s WOULD HAVE SHIPPED A FALSE TRIP, and it is a config a
|
||||
# schema-legal install can reach: `gain` 0.05 and `slew_w` 50 are both the
|
||||
# floor of what config.yaml accepts, and a +-2200 W load reversal is an oven
|
||||
# and a heat pump. That is the number this card exists to not assume.
|
||||
#
|
||||
# 325 s: 1.51x the measured worst, well inside the 900 s quarter that bills
|
||||
# the capacity tariff, and still inside every episode the fault day
|
||||
# contains - 2026-08-20's four clusters run 16, 30, 77 and 77 minutes and
|
||||
# its opposed runs reach 1750 s, so a 325 s window fires in all of them.
|
||||
# What it costs is stated rather than hidden: about two and a half extra
|
||||
# minutes of wrong-direction SITE power before the stop, bought to remove a
|
||||
# false trip that a legal configuration produces. ⚠️ DELIBERATELY NOT 300 OR
|
||||
# 360; the measurement is what it answers to.
|
||||
#
|
||||
# ⚠️ AND IT IS NOT THE PER-UNIT WINDOW EITHER, IN THE OTHER DIRECTION. The
|
||||
# per-unit comparison is 85 s because a unit's own power CHASES ITS OWN
|
||||
# COMMAND and the transient is two cycles; the site comparison is 325 s
|
||||
# because the meter is driven by the LOAD and the transient is the loop
|
||||
# crossing zero. Same predicate, two instruments, two windows, both measured.
|
||||
"site_sign_disagree_w": 300,
|
||||
"site_sign_disagree_s": 325,
|
||||
}
|
||||
|
||||
# ⚠️ A LIMIT OF THE SITE COMPARISON THAT SAFETY-30 DID NOT INTRODUCE AND DOES
|
||||
# NOT FIX, RECORDED HERE BECAUSE THE CAMPAIGN FOUND IT AND SILENCE WOULD BE
|
||||
# WORSE. The rig's other stimulus family is a FLAPPING LOAD, and a square wave
|
||||
# whose half period is about one control cycle opposes the command on EVERY
|
||||
# cycle: the command chases the previous half-cycle's meter while the meter has
|
||||
# already reversed. Across the 840 flapping runs the worst continuous opposition
|
||||
# at a 300 W threshold is 980 s at two inverters - and 1000 s at ONE, which is
|
||||
# the whole point. The N=1 arm is the control, and it says this is a property of
|
||||
# comparing a lagged command against a meter, not a property of the second
|
||||
# inverter. No window inside the 900 s billing quarter survives it, and no
|
||||
# threshold up to 1000 W does either.
|
||||
#
|
||||
# It is not acted on here for three reasons, in order of weight: it is identical
|
||||
# at the roster this add-on actually ships, so acting on it would be changing a
|
||||
# live safety path on evidence that has nothing to do with this card; a
|
||||
# ~6 kW square wave at 0.1 Hz sustained for a quarter of an hour is not a house
|
||||
# (the captured healthy day's longest opposed run is 30 s); and the fix is not a
|
||||
# number - it wants the detector to notice that the disagreement is ALTERNATING,
|
||||
# which is a different check. It is a card, and this comment is its evidence.
|
||||
|
||||
# SAFETY-30. THE TWO NOUNS THE TRIP SENTENCE CAN NAME, WRITTEN ONCE. They are
|
||||
# constants rather than literals at the call sites because `main.py` arms the
|
||||
# detectors and `test_watchdog.py` grades what they say, and a string typed in
|
||||
# two places is a string that drifts in one of them - the same argument
|
||||
# `store.unit_key()` makes about a key name. `AGAINST_METER` is the wording that
|
||||
# has always shipped and must not change: it is what a one-inverter install's
|
||||
# `reason` reads, in the store, in the action log and on the status page.
|
||||
AGAINST_METER = "a meter reading"
|
||||
AGAINST_OWN_POWER = "its own measured power"
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class SignWatchdogConfig:
|
||||
"""Defaults, not constants - config.yaml carries both (SAFETY-02 AC 5)."""
|
||||
@@ -206,7 +473,7 @@ class SignWatchdogConfig:
|
||||
hold_s: float = 180.0
|
||||
|
||||
|
||||
def disagrees(commanded_w, grid_w, following: bool,
|
||||
def disagrees(commanded_w, against_w, following: bool,
|
||||
cfg: SignWatchdogConfig) -> bool:
|
||||
"""The predicate, and the ONLY place it is written down.
|
||||
|
||||
@@ -215,12 +482,23 @@ def disagrees(commanded_w, grid_w, following: bool,
|
||||
inline. Two copies of a safety predicate is one copy plus a future
|
||||
disagreement about what the check means, and the copy that drifts is always
|
||||
the one in the harness that grades it.
|
||||
|
||||
⚠️ `against_w` WAS CALLED `grid_w`, AND THE RENAME IS THE WHOLE OF SAFETY-30
|
||||
IN ONE PARAMETER. The arithmetic is unchanged - opposed signs, neither side
|
||||
near zero, and the loop actually driving - but WHAT the command is opposed
|
||||
TO is now a property of the caller rather than a fact about this function.
|
||||
The site comparison hands it the meter; each unit's own comparison hands it
|
||||
that unit's measured power (register 0x0518). One predicate, two callers,
|
||||
for `loop_is_following()`'s reason: a safety predicate written down twice is
|
||||
one copy plus a future disagreement about what the check means. The
|
||||
parameter is positional at every call site in both repositories, so the
|
||||
rename moves no caller.
|
||||
"""
|
||||
return (following
|
||||
and commanded_w is not None and grid_w is not None
|
||||
and commanded_w * grid_w < 0
|
||||
and commanded_w is not None and against_w is not None
|
||||
and commanded_w * against_w < 0
|
||||
and abs(commanded_w) > cfg.min_w
|
||||
and abs(grid_w) > cfg.min_w)
|
||||
and abs(against_w) > cfg.min_w)
|
||||
|
||||
|
||||
def loop_is_following(resolution, loop_asked) -> bool:
|
||||
@@ -272,7 +550,17 @@ def loop_is_following(resolution, loop_asked) -> bool:
|
||||
|
||||
|
||||
class SignWatchdog:
|
||||
"""One instance per actuator, evaluated once per control cycle.
|
||||
"""One instance per COMPARISON, evaluated once per control cycle.
|
||||
|
||||
⚠️ SINCE SAFETY-30 THAT IS NOT THE SAME SENTENCE AS "one per actuator",
|
||||
which is what this docstring used to say. There is one instance per
|
||||
inverter - `Inverter.sign_wd`, latched under that unit's own store keys -
|
||||
AND one for the site, `Controller.site_sign_wd`, latched under flat ones.
|
||||
The two ask different questions of different evidence and reach different
|
||||
remedies; `arm()` below is where an instance is told which of them it is.
|
||||
At a roster of one they would be the same question, so only the per-unit
|
||||
instance is ever armed there - see the SAFETY-30 section of the module
|
||||
docstring.
|
||||
|
||||
⚠️ NOT SHARED ACROSS CADENCES. `disagree_since` is a wall-clock start time,
|
||||
so driving one instance from two loops at two rates would have each one
|
||||
@@ -282,8 +570,14 @@ class SignWatchdog:
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: SignWatchdogConfig | None = None, *,
|
||||
tripped: bool = False, reason: str = ""):
|
||||
tripped: bool = False, reason: str = "",
|
||||
against: str = AGAINST_METER):
|
||||
self.cfg = cfg or SignWatchdogConfig()
|
||||
# SAFETY-30. WHAT THE COMMAND IS BEING COMPARED AGAINST, as the operator
|
||||
# reads it in the trip sentence. The default is the meter, which is what
|
||||
# every trip this add-on has ever taken was compared against and is what
|
||||
# keeps a one-inverter install's `reason` string byte-identical.
|
||||
self.against = str(against)
|
||||
self.disagree_since: datetime | None = None
|
||||
# ⚠️ RESTORED FROM THE STORE, NOT DEFAULTED. A latch that lives only in
|
||||
# memory is not a latch: a container restart clears it, and the add-on
|
||||
@@ -292,8 +586,31 @@ class SignWatchdog:
|
||||
self.tripped = bool(tripped)
|
||||
self.reason = reason if self.tripped else ""
|
||||
|
||||
# -- which of SAFETY-30's two questions this instance is asking ----------
|
||||
def arm(self, cfg: SignWatchdogConfig, against: str) -> None:
|
||||
"""Set the thresholds and the subject of the comparison. Nothing else.
|
||||
|
||||
⚠️ IT IS CONFIGURATION, NOT STATE, AND IT DELIBERATELY DOES NOT TOUCH
|
||||
`disagree_since`, `tripped` OR `reason`. A detector that cleared its own
|
||||
window when it was told what it was comparing against would lose the
|
||||
episode it is in the middle of, every cycle, and would never accumulate
|
||||
a hold at all - the check would be permanently green and nothing would
|
||||
say so.
|
||||
|
||||
⚠️ AND IT IS RE-STATED EVERY CYCLE RATHER THAN FROZEN AT CONSTRUCTION.
|
||||
The answer is a property of the ROSTER and of nothing else, and
|
||||
`Controller.cycle()` already re-reads the roster every cycle for
|
||||
liveness and for the allocation. Freezing it in `__init__` would also
|
||||
make it wrong for any caller that appends an inverter afterwards, which
|
||||
is exactly how a two-inverter fixture is built in this repository - and
|
||||
a fixture that silently got the one-inverter comparison would grade
|
||||
nothing while looking green.
|
||||
"""
|
||||
self.cfg = cfg
|
||||
self.against = str(against)
|
||||
|
||||
# -- the whole check, and it is a pure function of its arguments ----------
|
||||
def evaluate(self, commanded_w, grid_w, following: bool,
|
||||
def evaluate(self, commanded_w, against_w, following: bool,
|
||||
now: datetime) -> bool:
|
||||
"""Advance the detector one cycle. Returns True while tripped.
|
||||
|
||||
@@ -301,15 +618,23 @@ class SignWatchdog:
|
||||
after deadband, slew, quantisation and the arbiter. Not
|
||||
the optimizer's raw wish: the wire carries the emitted
|
||||
value, so anything else can disagree with the meter for a
|
||||
reason that is not a fault.
|
||||
`grid_w` net P1, + = importing. None when the meter is stale or
|
||||
missing, which CLEARS the timer rather than accumulating
|
||||
- a frozen figure held against a moving command would
|
||||
otherwise manufacture a disagreement in about three
|
||||
minutes, on top of SAFETY-01 having already commanded
|
||||
zero for the same cause.
|
||||
reason that is not a fault. For a per-unit instance it is
|
||||
THAT UNIT'S share of it; for the site instance it is the
|
||||
roster sum.
|
||||
`against_w` what the command is graded against, and SAFETY-30 made
|
||||
this a decision rather than a fact: net P1 for the SITE
|
||||
comparison (+ = importing), and this unit's own measured
|
||||
power for the PER-UNIT one (+ = discharging, register
|
||||
0x0518). Both carry the same sign convention as the
|
||||
command, which is why one predicate serves both. None
|
||||
when the reading is stale or missing, which CLEARS the
|
||||
timer rather than accumulating - a frozen figure held
|
||||
against a moving command would otherwise manufacture a
|
||||
disagreement in about three minutes, on top of SAFETY-01
|
||||
having already commanded zero for the same cause.
|
||||
`following` did the grid-following loop actually win this cycle? See
|
||||
gate 1 in the module docstring.
|
||||
gate 1 in the module docstring, and the SAFETY-30 section
|
||||
on why the per-unit comparison keeps it.
|
||||
`now` the caller's clock, so this stays testable and replayable.
|
||||
"""
|
||||
if self.tripped:
|
||||
@@ -317,7 +642,7 @@ class SignWatchdog:
|
||||
return True
|
||||
|
||||
cfg = self.cfg
|
||||
if not disagrees(commanded_w, grid_w, following, cfg):
|
||||
if not disagrees(commanded_w, against_w, following, cfg):
|
||||
self.disagree_since = None
|
||||
return False
|
||||
|
||||
@@ -330,9 +655,17 @@ class SignWatchdog:
|
||||
return False
|
||||
|
||||
self.tripped = True
|
||||
# ⚠️ `self.against` IS THE ONLY THING SAFETY-30 CHANGED IN THIS STRING,
|
||||
# and it defaults to the wording that shipped - "a meter reading" - so a
|
||||
# one-inverter install's `reason` is byte-identical to what an operator
|
||||
# (and test_watchdog.py) has always read. A per-unit instance names what
|
||||
# it actually compared instead, because "commanded +1500 W against a
|
||||
# meter reading -1500 W" would be a false statement about which
|
||||
# instrument produced the evidence, on the one line somebody woken by
|
||||
# this alarm reads first.
|
||||
self.reason = (
|
||||
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against a meter "
|
||||
f"reading {grid_w:+.0f} W for {held:.0f} s continuously "
|
||||
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against "
|
||||
f"{self.against} {against_w:+.0f} W for {held:.0f} s continuously "
|
||||
f"(limits: both over {cfg.min_w:.0f} W, held over {cfg.hold_s:.0f} s)"
|
||||
)
|
||||
return True
|
||||
|
||||
@@ -60,7 +60,19 @@ options:
|
||||
# setpoint_entity: number.goodwe_b_setpoint_w
|
||||
# soc_entity: sensor.goodwe_b_soc
|
||||
# batt_entity: sensor.goodwe_b_battery_power
|
||||
# max_w: 3000
|
||||
# max_w: 4600
|
||||
#
|
||||
# ⚠️ THE 4600 IS INVERTER B'S DATASHEET FIGURE, NOT A MEASUREMENT AND NOT A
|
||||
# PLACEHOLDER. SPIKE-04a (2026-09-04) identified B as a GoodWe GW5048D-ES,
|
||||
# serial `55048ESU22AW0992`, whose datasheet gives Max. Charging / Discharging
|
||||
# Power as 4600 W; nothing will be connected to its MPPTs, so the battery path
|
||||
# is the ceiling and the 5000 VA AC nameplate is not. The 3000 W this example
|
||||
# used to carry was a guess made before the unit was known. ⚠️ It is STILL not
|
||||
# measured: the datasheet prints 4600 W under BATTERY INPUT DATA, so it may be
|
||||
# DC, and `max_w` is graded against 0x0518 - the inverter's own AC power. If it
|
||||
# is DC the AC ceiling is nearer 4324 W. SAFETY-20's `min(max_w, dev_max)` is
|
||||
# what settles that once the device range is read; see goodwe/NOTES.md §1.1b,
|
||||
# which records both readings and picks neither.
|
||||
#
|
||||
# ⚠️ NOTHING IS INHERITED FROM THE FLAT KEYS BY AN ENTRY THAT OMITS IT, and
|
||||
# that is the whole of DEV-02 restated as a config rule. `soc`, `batt` and the
|
||||
@@ -167,6 +179,62 @@ options:
|
||||
sign_disagree_w: 300
|
||||
sign_disagree_s: 180
|
||||
|
||||
# --- SAFETY-30 per-inverter sign-disagreement watchdog ---------------------
|
||||
# ⚠️ A DIFFERENT COMPARISON, NOT A SECOND COPY OF THE ONE ABOVE, AND IT IS
|
||||
# ARMED ONLY WHEN THIS SITE HAS MORE THAN ONE INVERTER. The pair above grades
|
||||
# the SITE's total command against P1 - one meter, one grid connection. This
|
||||
# pair grades EACH inverter's own share against THAT inverter's own measured
|
||||
# power (holding register 0x0518), and it catches the fault the meter cannot
|
||||
# answer for once there are two units: a unit doing the opposite of what it
|
||||
# was told, while its sibling covers for it and P1 reads exactly what a
|
||||
# healthy site reads.
|
||||
#
|
||||
# At ONE inverter these two keys do nothing at all. §6.2's identity makes the
|
||||
# site's total command that inverter's command, so the pair above is already
|
||||
# asking this question of the same actuator, and arming a second detector
|
||||
# would be two latches and two banners for one fault.
|
||||
#
|
||||
# Both defaults are measured on admin/goodwe's two-master rig, over 1890
|
||||
# closed-loop runs in which nothing is faulty, swept across the whole range
|
||||
# this file accepts for `gain` and `slew_w`. 250 W is `saturation_w / 2`, so
|
||||
# the smallest divergence this can see is exactly the gap at which the control
|
||||
# law itself already says the inverter is not following; 85 s is 8.5x the
|
||||
# worst legitimate opposition those runs produce (10.0 s), 2.8x the firmware's
|
||||
# own 30 s link veto, and under half the 180 s the site check takes. See
|
||||
# app/watchdog.py's SIGN_OPTION_DEFAULTS and
|
||||
# DECISIONS/SAFETY-30-per-unit-sign.md.
|
||||
#
|
||||
# ⚠️ unit_sign_disagree_w must stay BELOW max_w, for sign_disagree_w's reason:
|
||||
# a share is bounded to +-max_w, so a threshold at or above it can never fire.
|
||||
# validate.py refuses that config.
|
||||
unit_sign_disagree_w: 250
|
||||
unit_sign_disagree_s: 85
|
||||
|
||||
# --- SAFETY-30 SITE sign-disagreement watchdog -----------------------------
|
||||
# ⚠️ THE SAME COMPARISON `sign_disagree_*` MAKES, AT THE ROSTER WHERE IT STOPS
|
||||
# BEING A STATEMENT ABOUT ONE INVERTER. At two or more units the SUM of the
|
||||
# standing commands is graded against P1, and the trip stops the whole site -
|
||||
# what it catches is the site being asked for the wrong thing, which every
|
||||
# per-inverter check is blind to because each unit is faithfully executing its
|
||||
# share. At ONE inverter these two keys do nothing: `sign_disagree_*` above is
|
||||
# already asking this of the same actuator.
|
||||
#
|
||||
# The threshold is the shipped 300 W, CARRIED, and the reason is that the
|
||||
# argument behind it does not depend on the roster: near zero the sign is
|
||||
# noise, the deadband is 15 W, and there is one P1 whatever is behind it.
|
||||
#
|
||||
# ⚠️ THE WINDOW IS NOT CARRIED, AND THAT IS A MEASUREMENT. The transient 180 s
|
||||
# exists to reject is the loop crossing zero after a load reversal, and the
|
||||
# command has to travel the whole SITE rail at `slew_w` per cycle - a rail
|
||||
# that is the roster sum while `slew_w` is not. On 1890 two-inverter runs in
|
||||
# which nothing is faulty, the worst continuous legitimate opposition at 300 W
|
||||
# is 110 s at one inverter and 215 s at two: carrying 180 s across would have
|
||||
# shipped a false trip reachable at `gain: 0.05`, `slew_w: 50` and an ordinary
|
||||
# 2.2 kW load reversal. 325 s is 1.51x that, inside the 900 s billing quarter,
|
||||
# and still inside every episode of the 2026-08-20 fault day.
|
||||
site_sign_disagree_w: 300
|
||||
site_sign_disagree_s: 325
|
||||
|
||||
# --- SAFETY-18 frozen-but-fresh meter detector -----------------------------
|
||||
# Seconds the meter may keep answering with an UNCHANGED measurement while the
|
||||
# command stands at the rail before the add-on raises an alarm. Both halves
|
||||
@@ -487,6 +555,33 @@ schema:
|
||||
sign_disagree_w: int(50,5000)
|
||||
sign_disagree_s: int(30,1800)
|
||||
|
||||
# SAFETY-30. No "off" value, for SAFETY-02's reason.
|
||||
#
|
||||
# ⚠️ THE THRESHOLD'S RANGE IS THE SAME AS THE SITE CHECK'S ON PURPOSE, AND THE
|
||||
# WINDOW'S FLOOR IS NOT. On the two-inverter rig the per-unit comparison's
|
||||
# worst continuous legitimate opposition is nearly FLAT in the threshold -
|
||||
# 25.0 s at 50 W, 15.0 s at 150 W, 10.0 s at 250 W, 5.0 s at 500 W - because a
|
||||
# unit's own power chases its own command rather than the load. So no value in
|
||||
# this range puts the guard outside the regime it can be answered for, and the
|
||||
# floor does not have to be a knee the way `circulation_w`'s does.
|
||||
unit_sign_disagree_w: int(50,5000)
|
||||
# The floor of 30 is `inverter.LINK_STALE_S`, the firmware's own veto window:
|
||||
# below it, a unit not executing its share is a LINK fault the add-on already
|
||||
# answers by dropping the unit from the split, and firing inside that window
|
||||
# would be a second, louder alarm about a state that is already being handled.
|
||||
unit_sign_disagree_s: int(30,1800)
|
||||
|
||||
# SAFETY-30's SITE pair. Same ranges as `sign_disagree_*`, because it is the
|
||||
# same comparison asked of the site total - and no "off" value, for the same
|
||||
# reason. ⚠️ THERE IS DELIBERATELY NO validate.py RULE PAIRING
|
||||
# site_sign_disagree_w WITH max_w, unlike the other two thresholds: the bound
|
||||
# on the SITE command is `Controller.site_max_w`, the ROSTER SUM, and
|
||||
# `validate_startup_config()` is handed options rather than a roster. A rule
|
||||
# written against max_w would refuse a perfectly reachable two-inverter
|
||||
# configuration the day CFG-04 lands. The schema range is the bound here.
|
||||
site_sign_disagree_w: int(50,5000)
|
||||
site_sign_disagree_s: int(30,1800)
|
||||
|
||||
# No "off" value, for SAFETY-02's reason: disarming a safety alarm is not a
|
||||
# supported configuration. ⚠️ THE FLOOR OF 60 IS NOT A RECOMMENDATION. At 300 s
|
||||
# the slowest a HEALTHY meter's 1 Wh register can tick and still look unchanged
|
||||
|
||||
@@ -165,21 +165,29 @@ SITE_SOURCES = {
|
||||
"identically zero for any one unit - there is no fact of "
|
||||
"the matter about which of two opposing inverters is the "
|
||||
"offender, so there is nothing to file it per-unit on",
|
||||
# SAFETY-30, and it is the entry most easily confused with `failsafe`
|
||||
# below, because the same three words describe both.
|
||||
"sign_site": "the SUM of every standing command against the meter. The "
|
||||
"offending number is the SITE target, which no single "
|
||||
"inverter owns - parking one of them would leave the rest "
|
||||
"pushing the same way with the guard satisfied",
|
||||
}
|
||||
UNIT_SOURCES = {
|
||||
"device": "one inverter's own reported min/max rating",
|
||||
"supervised": "max_w caps what may be WRITTEN to one setpoint entity",
|
||||
"failsafe": "site-wide evidence, per-unit remedy: SAFETY-02 grades the "
|
||||
"command THIS controller put on THIS actuator",
|
||||
"failsafe": "per-unit evidence, per-unit remedy: since SAFETY-30 it "
|
||||
"grades THIS unit's command against THIS unit's OWN "
|
||||
"measured power (0x0518), so what it learns is about one "
|
||||
"device. The site-wide half moved to `sign_site`",
|
||||
"maintenance": "the monthly recalibration is a pack procedure",
|
||||
}
|
||||
for _src, _why in sorted(SITE_SOURCES.items()):
|
||||
print(f" site {_src:<11} {_why}")
|
||||
for _src, _why in sorted(UNIT_SOURCES.items()):
|
||||
print(f" unit {_src:<11} {_why}")
|
||||
check("all NINE claim sources are classified, and only those nine",
|
||||
check("all TEN claim sources are classified, and only those ten",
|
||||
set(CLAIM_SCOPE) == set(SITE_SOURCES) | set(UNIT_SOURCES))
|
||||
check("the five that are about the GRID CONNECTION are site claims",
|
||||
check("the six that are about the GRID CONNECTION are site claims",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE} == set(SITE_SOURCES))
|
||||
check("the four that are about a PACK, a DEVICE or one write are per-inverter",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT} == set(UNIT_SOURCES))
|
||||
@@ -200,7 +208,7 @@ check("with one inverter every source routes to the site, per-inverter ones "
|
||||
check("...and with none configured at all, likewise",
|
||||
all(actuator_for(s, "inverter-a", ()) == ACTUATOR_SITE for s in CLAIM_SCOPE))
|
||||
check("with TWO the identity breaks and the split becomes real: the four "
|
||||
"per-inverter sources route to the unit this controller drives, the five "
|
||||
"per-inverter sources route to the unit this controller drives, the six "
|
||||
"site sources stay on the grid connection",
|
||||
{s: actuator_for(s, "inverter-a", TWO) for s in CLAIM_SCOPE}
|
||||
== {**{s: "inverter-a" for s in UNIT_SOURCES},
|
||||
|
||||
@@ -192,9 +192,16 @@ class Hass:
|
||||
|
||||
A_ENT = {"setpoint_entity": "number.sp_a", "soc_entity": "sensor.soc_a",
|
||||
"batt_entity": "sensor.batt_a"}
|
||||
# ⚠️ A HYPOTHESIS, NOT A MEASUREMENT. Inverter B does not exist; 3000 W is
|
||||
# chosen only because it DIFFERS from A's 5000 W, which is what lets a check
|
||||
# tell B's number from A's. SPIKE-04 measures the real one.
|
||||
# ⚠️ SPIKE-04a (2026-09-04) ESTABLISHED B'S REAL RATING FROM ITS DATASHEET:
|
||||
# a GoodWe GW5048D-ES, serial `55048ESU22AW0992`, 4600 W on the battery path
|
||||
# (goodwe/NOTES.md §1.1b). THIS FIXTURE DELIBERATELY DOES NOT USE IT. 3000 W is
|
||||
# kept because the only property these checks consume is that B's number is
|
||||
# UNMISTAKABLY not A's, and the real pair is 5000/4600 - a 400 W gap, narrower
|
||||
# than `slew_w` and inside the range where an off-by-one-unit bug and ordinary
|
||||
# control arithmetic produce indistinguishable numbers. Collapsing the fixture
|
||||
# onto the real values would cost these checks their separating power to buy
|
||||
# realism they do not use. So: ILLUSTRATIVE, NOT B'S RATING, and not a
|
||||
# placeholder for it either - the placeholder era ended on 2026-09-04.
|
||||
B_RATING_HYPOTHESIS = 3000.0
|
||||
A_RATING = 5000.0
|
||||
|
||||
@@ -572,6 +579,58 @@ check("...and a store that only fails to persist a DEFAULT is not reported as "
|
||||
"dismiss before the real one arrives",
|
||||
migrate_unit_keys(LosesTheLatch(), UNIT_A).ok is True)
|
||||
|
||||
# ⚠️ AND THE MARKER GATE, ON A STORE WHERE SOMETHING WAS ALREADY NAMESPACED.
|
||||
# FOUND BY MAINT-05's ROUND-3 BATTERY, AND IT WAS A SURVIVOR OF ALL 19 FILES.
|
||||
# `migrate_unit_keys()` gates `SCHEMA_KEY` on `rep.ok`, and every check above
|
||||
# reaches that gate on a store where NOTHING was already under `unit/...` - so
|
||||
# `rep.kept` is empty in all of them, and the mutation
|
||||
#
|
||||
# if rep.ok: -> if rep.ok or rep.kept:
|
||||
#
|
||||
# stamped the marker on a migration that DROPPED THE LATCH, with the whole suite
|
||||
# green. That is a disarmed safety guard plus a store that says the migration
|
||||
# finished, so the next start skips the one thing that would have re-armed it -
|
||||
# DEV-02's own worst case with the paper trail filed under "done".
|
||||
#
|
||||
# The fixture is the one shape that separates them: `sign_reason` ALREADY
|
||||
# namespaced (so `kept` is non-empty and the mutant's `or` fires) and the
|
||||
# `sign_tripped: true` write dropped on the floor (so `lost` is non-empty and
|
||||
# `ok` is False). `migrate_unit_keys()` is passed no roster, so `misdirected`
|
||||
# cannot be what refuses this - it is the `lost` guard or nothing.
|
||||
_kept_reason = "SIGN_DISAGREEMENT: already namespaced by a later version"
|
||||
_broken_kept = LosesTheLatch({
|
||||
"sign_tripped": True,
|
||||
"sign_reason": "SIGN_DISAGREEMENT: measured",
|
||||
unit_key(UNIT_A, "sign_reason"): _kept_reason})
|
||||
_rep_kept = migrate_unit_keys(_broken_kept, UNIT_A)
|
||||
print(f" a dropped latch write beside an already-namespaced reason: "
|
||||
f"{_rep_kept.explain()}")
|
||||
print(f" lost={len(_rep_kept.lost)} kept={len(_rep_kept.kept)} "
|
||||
f"ok={_rep_kept.ok}; marker "
|
||||
f"{_broken_kept.data.get(SCHEMA_KEY, '<<absent>>')!r}")
|
||||
check("PRECONDITION: this fixture reaches the marker gate through the `lost` "
|
||||
"guard with a NON-EMPTY `kept`, which is the combination none of the "
|
||||
"checks above has. One key dropped, one key left alone, `ok` False. If a "
|
||||
"later edit empties `kept` here the mutation goes invisible again, so the "
|
||||
"shape is asserted rather than assumed",
|
||||
_rep_kept.ran and len(_rep_kept.lost) == 1 and len(_rep_kept.kept) == 1
|
||||
and not _rep_kept.ok
|
||||
and _broken_kept.data[unit_key(UNIT_A, "sign_reason")] == _kept_reason)
|
||||
check("⚠️ AND THE STORE IS NOT MARKED MIGRATED. The key that was ALREADY there "
|
||||
"does not buy a marker for the latch that was not: stamping here would "
|
||||
"tell the next start that the migration which dropped `sign_tripped` had "
|
||||
"finished, so it would never run again and the guard would stay off on an "
|
||||
"install whose file still reads `sign_tripped: true`",
|
||||
SCHEMA_KEY not in _broken_kept.data)
|
||||
check("...and the counterfactual, one property different: the SAME store shape "
|
||||
"on a store that does not drop writes IS marked migrated. So the refusal "
|
||||
"above is about the latch that was lost, not about `kept` being non-empty",
|
||||
migrate_unit_keys(
|
||||
MemStore({"sign_tripped": True,
|
||||
"sign_reason": "SIGN_DISAGREEMENT: measured",
|
||||
unit_key(UNIT_A, "sign_reason"): _kept_reason}),
|
||||
UNIT_A).ok is True)
|
||||
|
||||
_broken2 = LosesTheLatch({"sign_tripped": True,
|
||||
"sign_reason": "SIGN_DISAGREEMENT: measured"})
|
||||
_c2d, _ = built(store=_broken2)
|
||||
@@ -609,28 +668,40 @@ print("3. AC 3: a trip on B does not latch A, and it survives a restart")
|
||||
# inverters get a share of ONE site target, so an ordinary wrong-way loop trips
|
||||
# BOTH - correctly, because both really are pushing the wrong way. The state
|
||||
# this part is about is the one the flat store keys made unreachable: ONE
|
||||
# inverter standing on a command that opposes the meter while the other does
|
||||
# not. It is reached the way the field would reach it - inverter B's writes are
|
||||
# being REJECTED, so `inv.last_write` stays where it was while A's tracks the
|
||||
# loop - and `standing` is what SAFETY-02 grades, per unit.
|
||||
# inverter standing on a command that opposes what it is graded against while
|
||||
# the other does not. It is reached the way the field would reach it - inverter
|
||||
# B's writes are being REJECTED, so `inv.last_write` stays where it was while
|
||||
# A's tracks the loop - and `standing` is what SAFETY-02 grades, per unit.
|
||||
#
|
||||
# ⚠️ SAFETY-30 CHANGED WHAT "OPPOSES" MEANS HERE, AND THE FIXTURE HAD TO MOVE
|
||||
# WITH IT - WHICH IS THIS CHECK DOING ITS JOB. It used to stand B on a -1500 W
|
||||
# charge against a +2000 W METER and let the site figure convict it. At a roster
|
||||
# of two that comparison is exactly the defect SAFETY-30 removes: the meter
|
||||
# answers for BOTH inverters, so it is evidence about neither. B is now
|
||||
# convicted by its OWN power sensor - standing on a -1500 W charge while
|
||||
# `sensor.batt_b` measures it DISCHARGING at +1500 W, which is one inverter
|
||||
# doing the opposite of what it was told and is a fact about that inverter
|
||||
# alone. Inverter A's own reading stays at 0 W, so A is never gated in.
|
||||
#
|
||||
# ⚠️ AND THE REJECTION WINDOW IS WHY THIS RUNS IN THREE SECONDS AND NOT THIRTY.
|
||||
# `sign_disagree_s` is 1 s here; `LINK_STALE_S` is 30 s, so B is still LIVE for
|
||||
# the whole run and the trip is graded before liveness has anything to say.
|
||||
# `unit_sign_disagree_s` is 1 s here; `LINK_STALE_S` is 30 s, so B is still LIVE
|
||||
# for the whole run and the trip is graded before liveness has anything to say.
|
||||
def _tripping_site():
|
||||
hass = Hass(
|
||||
{"sensor.grid": 2000.0, "sensor.soc_a": 50.0, "sensor.batt_a": 0.0,
|
||||
"sensor.soc_b": 50.0, "sensor.batt_b": 0.0},
|
||||
"sensor.soc_b": 50.0, "sensor.batt_b": 1500.0},
|
||||
{"number.sp_a": (-A_RATING, A_RATING, 1.0),
|
||||
"number.sp_b": (-B_RATING_HYPOTHESIS, B_RATING_HYPOTHESIS, 1.0)},
|
||||
reject={"number.sp_b"})
|
||||
store = MemStore()
|
||||
c, _ = built({"sign_disagree_w": 300, "sign_disagree_s": 1,
|
||||
"unit_sign_disagree_w": 300, "unit_sign_disagree_s": 1,
|
||||
"auto_start": True}, store=store, hass=hass)
|
||||
c.inverters.append(inverter_b(store, sign_cfg=c.inverters[0].sign_wd.cfg))
|
||||
c.auto = True
|
||||
# B is standing on a charge command while the house imports 2000 W. Its
|
||||
# writes are rejected, so this is what it goes on standing at.
|
||||
# B is standing on a charge command while its own sensor says it is
|
||||
# discharging. Its writes are rejected, so this is what it goes on
|
||||
# standing at.
|
||||
c.inverters[1].last_write = -1500.0
|
||||
return c, hass, store
|
||||
|
||||
@@ -681,10 +752,12 @@ check("⚠️ ...AND THE TRIP IS MIRRORED ONTO THE PRE-DEV-02 FLAT PAIR, WHICH I
|
||||
|
||||
# THE RESTART, which is the whole reason the latch is persisted at all.
|
||||
_h3b = Hass({"sensor.grid": 2000.0, "sensor.soc_a": 50.0,
|
||||
"sensor.batt_a": 0.0, "sensor.soc_b": 50.0, "sensor.batt_b": 0.0},
|
||||
"sensor.batt_a": 0.0, "sensor.soc_b": 50.0,
|
||||
"sensor.batt_b": 1500.0},
|
||||
{"number.sp_a": (-A_RATING, A_RATING, 1.0),
|
||||
"number.sp_b": (-B_RATING_HYPOTHESIS, B_RATING_HYPOTHESIS, 1.0)})
|
||||
_c3r, _ = built({"sign_disagree_w": 300, "sign_disagree_s": 1,
|
||||
"unit_sign_disagree_w": 300, "unit_sign_disagree_s": 1,
|
||||
"auto_start": True}, store=_s3, hass=_h3b)
|
||||
_c3r.inverters.append(inverter_b(_s3,
|
||||
sign_cfg=_c3r.inverters[0].sign_wd.cfg))
|
||||
@@ -703,12 +776,32 @@ check("a brand new Controller against the same store comes back with B "
|
||||
check("...and A goes on carrying the site target across the restart too",
|
||||
_c3r.allocation.shares.get("inverter-a") == _c3r.allocation.sum_w
|
||||
and _c3r.allocation.sum_w != 0)
|
||||
check("...and the status page shows BOTH rows - one latched, one armed. A "
|
||||
"single row would have to pick one inverter to describe, and 'the sign "
|
||||
"watchdog is armed' printed over a latched sibling is the page lying",
|
||||
len([r for r in _c3r.checks() if "sign watchdog" in r["text"]]) == 1
|
||||
check("...and the status page shows BOTH per-inverter rows - one latched, one "
|
||||
"armed. A single row would have to pick one inverter to describe, and "
|
||||
"'the sign watchdog is armed' printed over a latched sibling is the page "
|
||||
"lying",
|
||||
len([r for r in _c3r.checks()
|
||||
if r["text"].startswith("sign watchdog [")]) == 1
|
||||
and len([r for r in _c3r.checks()
|
||||
if "SIGN-DISAGREEMENT FAILSAFE" in r["text"]]) == 1)
|
||||
if "SIGN-DISAGREEMENT FAILSAFE [" in r["text"]]) == 1)
|
||||
check("⚠️ AND SAFETY-30's SITE ROW IS THERE BESIDE THEM, EXACTLY ONCE. At two "
|
||||
"inverters there are three sign questions on this page and they are three "
|
||||
"rows: is A doing what it was told, is B, and is the SITE'S TOTAL "
|
||||
"pointing the right way. The last one is not derivable from the other "
|
||||
"two - both units can execute their shares perfectly while the number "
|
||||
"they were given is itself wrong - so a page that showed only the "
|
||||
"per-unit rows would be advertising two guards where the install has "
|
||||
"three",
|
||||
len([r for r in _c3r.checks()
|
||||
if r["text"].startswith("site sign watchdog:")]) == 1)
|
||||
check("...and the per-inverter rows now say WHAT the unit was compared "
|
||||
"against, because at a roster of two it is no longer the meter. A row "
|
||||
"still reading 'the command opposed the meter' would send an operator to "
|
||||
"look at P1 for a fault that is visible only on one inverter's own power "
|
||||
"sensor",
|
||||
all("its own measured power" in r["text"] for r in _c3r.checks()
|
||||
if r["text"].startswith(("sign watchdog [",
|
||||
"SIGN-DISAGREEMENT FAILSAFE ["))))
|
||||
|
||||
# The operator's clear, which is one button and has to reach every latch.
|
||||
run(_c3r.handle_action("auto_toggle")) # -> stopped
|
||||
@@ -728,8 +821,9 @@ check("...and the same press cleared the flat rollback view, so a downgrade "
|
||||
"- and neither does the next start, which now reads that key on EVERY "
|
||||
"boot rather than only on the one that migrates",
|
||||
_s3.data["sign_tripped"] is False and _s3.data["sign_reason"] == "")
|
||||
_c3r2, _ = built({"sign_disagree_w": 300, "sign_disagree_s": 1}, store=_s3,
|
||||
hass=_h3b)
|
||||
_c3r2, _ = built({"sign_disagree_w": 300, "sign_disagree_s": 1,
|
||||
"unit_sign_disagree_w": 300, "unit_sign_disagree_s": 1},
|
||||
store=_s3, hass=_h3b)
|
||||
check("⚠️ AND THE RESTART AFTER THAT CLEAR COMES UP UNLATCHED. This is the "
|
||||
"'re-arm forever' hazard the every-start guard would have if the clear "
|
||||
"did not reach both spellings, driven through the real button and a real "
|
||||
@@ -1594,11 +1688,28 @@ check("⚠️ RULE 5 NAMES THE UNIT THE NUMBER CAME OFF. The weakest cap is "
|
||||
"is inverter-B. The refusal says inverter-c",
|
||||
_why(_p_skew, "max_w (inverter-c) is 1000 W")
|
||||
and not _why(_p_skew, "max_w (inverter-b) is 1000 W"))
|
||||
check("⚠️ RULE 6 TOO. `caps[0]` is the first entry WITH a usable cap - "
|
||||
"inverter-b - while `_unit_label(opts, 0)` was hard-wired to inverter-a, "
|
||||
"so the maintenance refusal quoted B's rating under A's name",
|
||||
_why(_p_skew, "max_w (inverter-b) is 2000 W")
|
||||
and not _why(_p_skew, "max_w (inverter-a) is 2000 W"))
|
||||
# ⚠️ MAINT-05 MOVED RULE 6's SUBJECT, AND THIS CHECK MOVED WITH IT. It used to
|
||||
# assert the refusal named inverter-b, because rule 6 graded the FIRST entry
|
||||
# with a usable cap - `Controller.maint_unit` was `inverters[0]` and the shaping
|
||||
# claim could be filed nowhere else. There is now one `Maintenance` per roster
|
||||
# entry, so the shaping claim can be filed on ANY pack and the cap that
|
||||
# contradicts it first is the SMALLEST - inverter-c's 1000 W. The property this
|
||||
# check exists for is unchanged and is the reason it is still here: the index
|
||||
# has to travel with the cap, or the message quotes one unit's rating under
|
||||
# another unit's name.
|
||||
check("⚠️ RULE 6 TOO, AND SINCE MAINT-05 IT IS THE WEAKEST PACK IT NAMES. "
|
||||
"inverter-c's 1000 W sits at caps index 1, and `_unit_label(opts, 1)` is "
|
||||
"inverter-B - so a caps index leaking into a roster index would say "
|
||||
"inverter-b here. The refusal says inverter-c, with inverter-c's number",
|
||||
_why(_p_skew, "maintenance_charge_w is 3000 W but max_w (inverter-c) is "
|
||||
"1000 W")
|
||||
and not _why(_p_skew, "maintenance_charge_w is 3000 W but max_w "
|
||||
"(inverter-b)"))
|
||||
check("...and it is no longer graded against the FIRST usable cap at all, which "
|
||||
"is the behaviour change MAINT-05 makes here: inverter-b's 2000 W was the "
|
||||
"pre-card answer and appears nowhere in the maintenance refusal now",
|
||||
not _why(_p_skew, "maintenance_charge_w is 3000 W but max_w "
|
||||
"(inverter-b) is 2000 W"))
|
||||
check("...and the counterfactual, so this is not a check that would pass on a "
|
||||
"validator that named nothing: the OLD expressions still evaluate, on "
|
||||
"this same config, to the wrong names",
|
||||
@@ -2097,6 +2208,16 @@ MUTATIONS = [
|
||||
("validate.py allowing two roster entries with the SAME name",
|
||||
"part 10: 'two entries with the SAME name are refused' - one Store "
|
||||
"namespace for two units is DEV-02's defect rebuilt in YAML"),
|
||||
("`migrate_unit_keys()`'s marker gate `if rep.ok:` -> `if rep.ok or "
|
||||
"rep.kept:` - the schema marker stamped on a migration that DROPPED THE "
|
||||
"LATCH, because one key happened to be namespaced already",
|
||||
"part 10: 'AND THE STORE IS NOT MARKED MIGRATED'. ⚠️ THIS ONE SURVIVED "
|
||||
"ALL 19 FILES and was found by MAINT-05's round-3 battery, not by this "
|
||||
"card: every migration check here reached the gate on a store where "
|
||||
"NOTHING was namespaced yet, so `rep.kept` was empty in all of them and "
|
||||
"the `or` never fired. Stamping there disarms the latch AND tells the "
|
||||
"next start the migration finished, so it never re-arms - DEV-02's own "
|
||||
"worst case filed under 'done'"),
|
||||
]
|
||||
# ⚠️ FOUR OF THESE SURVIVED THE FIRST TIME AND THE CHECKS WERE CHANGED, NOT THE
|
||||
# TABLE - two in DEV-02, two more in CFG-04, and the CFG-04 pair are recorded in
|
||||
@@ -2115,7 +2236,7 @@ for what, caught in MUTATIONS:
|
||||
check(f"all {len(MUTATIONS)} defeats of this card are caught by a named check "
|
||||
f"above. A guard whose checks survive its own defeat is not a guard, and "
|
||||
f"this repository has three separate records of exactly that",
|
||||
len(MUTATIONS) == 34)
|
||||
len(MUTATIONS) == 35)
|
||||
|
||||
|
||||
print()
|
||||
|
||||
File diff suppressed because it is too large
Load Diff
@@ -2410,8 +2410,19 @@ check("...and so does the persistent notification, which outlives the page and "
|
||||
# loop} at every SoC from 0 to 100 %, because nothing in those fixtures
|
||||
# circulates. What it does is stop the site when two inverters are measured
|
||||
# pushing against each other. See DECISIONS/SAFETY-31-circulating-power.md.
|
||||
# ⚠️ SAFETY-30 ADDED THE TENTH, AND IT NEEDS ITS OWN PARAGRAPH FOR THE REASON
|
||||
# `circulation` needed one. `sign_site` is a SET at P_SAFETY on the SITE
|
||||
# actuator, filed only while `site_sign_wd.tripped` AND the roster holds more
|
||||
# than one inverter. It is not a second copy of `failsafe`: that one grades ONE
|
||||
# unit's command against THAT unit's own measured power and parks that unit,
|
||||
# while this grades the SUM of the commands against the meter and stops the
|
||||
# site. It appears in NO cycle of the sweeps below - the dynamic halves still
|
||||
# observe exactly {device, supervised, loop} at every SoC, because the shipped
|
||||
# roster is one inverter and this claim cannot be filed there at all. See
|
||||
# DECISIONS/SAFETY-30-per-unit-sign.md.
|
||||
CLAIM_SOURCES = {"device", "supervised", "failsafe", "safety", "peak",
|
||||
"arbitrage", "maintenance", "loop", "circulation"}
|
||||
"arbitrage", "maintenance", "loop", "circulation",
|
||||
"sign_site"}
|
||||
# The two appends that file a claim BUILT ELSEWHERE in the method. Named here so
|
||||
# that a THIRD such indirection reads as an unrecognised append rather than as a
|
||||
# silent gap in the scan.
|
||||
@@ -2590,13 +2601,17 @@ print(" site: " + ", ".join(sorted(s for s, v in CLAIM_SCOPE.items()
|
||||
if v == SCOPE_SITE))
|
||||
+ " | per-inverter: "
|
||||
+ ", ".join(sorted(s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT)))
|
||||
check("...and the split is the one ARB-03 argued, with SAFETY-31's addition: "
|
||||
"the five about the GRID CONNECTION are site claims and the four about a "
|
||||
"pack, a device or one write are per-inverter. `circulation` is a site "
|
||||
"claim because its quantity is defined over the roster and is identically "
|
||||
"zero for any one unit - there is no inverter to attribute it to",
|
||||
check("...and the split is the one ARB-03 argued, with SAFETY-31's and "
|
||||
"SAFETY-30's additions: the six about the GRID CONNECTION are site "
|
||||
"claims and the four about a pack, a device or one write are "
|
||||
"per-inverter. `circulation` is a site claim because its quantity is "
|
||||
"defined over the roster and is identically zero for any one unit; "
|
||||
"`sign_site` is one because the number that tripped it is the SITE "
|
||||
"target, which no single inverter owns - while `failsafe` beside it is "
|
||||
"per-inverter because since SAFETY-30 it grades one unit's command "
|
||||
"against that unit's OWN measured power",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE}
|
||||
== {"loop", "peak", "arbitrage", "safety", "circulation"}
|
||||
== {"loop", "peak", "arbitrage", "safety", "circulation", "sign_site"}
|
||||
and {s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT}
|
||||
== {"device", "supervised", "failsafe", "maintenance"})
|
||||
|
||||
@@ -2644,6 +2659,16 @@ check("...and the arbiter agrees the routing is legal, on the list main.py "
|
||||
# DATA could not reach the failure it named (ARB-03's call-site scan saw 3 of 8
|
||||
# sites; ALLOC-01's replay generator saw 0 escapes where a widened one saw
|
||||
# 39,991), so the number is different HERE, once, for every fixture in the file.
|
||||
# ⚠️ SPIKE-04a (2026-09-04) ESTABLISHED B'S REAL RATING FROM ITS DATASHEET:
|
||||
# a GoodWe GW5048D-ES, serial `55048ESU22AW0992`, 4600 W on the battery path
|
||||
# (goodwe/NOTES.md §1.1b). THIS FIXTURE DELIBERATELY DOES NOT USE IT. 3000 W is
|
||||
# kept because the only property these checks consume is that B's number is
|
||||
# UNMISTAKABLY not A's, and the real pair is 5000/4600 - a 400 W gap, narrower
|
||||
# than `slew_w` and inside the range where an off-by-one-unit bug and ordinary
|
||||
# control arithmetic produce indistinguishable numbers. Collapsing the fixture
|
||||
# onto the real values would cost these checks their separating power to buy
|
||||
# realism they do not use. So: ILLUSTRATIVE, NOT B'S RATING, and not a
|
||||
# placeholder for it either - the placeholder era ended on 2026-09-04.
|
||||
B_RATING_HYPOTHESIS = LIVE_MAX_W - 2000.0
|
||||
|
||||
|
||||
@@ -2672,19 +2697,21 @@ _restore_b()
|
||||
print(" with a second inverter on the roster, main.py routes: "
|
||||
+ ", ".join(f"{s}->{a}" for s, a in sorted(_routed.items())))
|
||||
check("⚠️ AND THIS IS THE BREAKING HALF. Give the same Controller a second "
|
||||
"inverter and its OWN routing method splits the nine: `device`, "
|
||||
"inverter and its OWN routing method splits the ten: `device`, "
|
||||
"`supervised`, `failsafe` and `maintenance` bind the unit this controller "
|
||||
"drives, `loop`, `peak`, `arbitrage`, `safety` and SAFETY-31's "
|
||||
"`circulation` stay on the grid connection. Swap any one of them - route "
|
||||
"`peak` to the unit and the site keeps no floor; route `maintenance` to "
|
||||
"the site and it can cross that floor into `lo > hi`; route `circulation` "
|
||||
"to one unit and a site-wide loop parks the inverter that may well be the "
|
||||
"one still listening - and this line goes red",
|
||||
"drives, `loop`, `peak`, `arbitrage`, `safety`, SAFETY-31's `circulation` "
|
||||
"and SAFETY-30's `sign_site` stay on the grid connection. Swap any one of "
|
||||
"them - route `peak` to the unit and the site keeps no floor; route "
|
||||
"`maintenance` to the site and it can cross that floor into `lo > hi`; "
|
||||
"route `circulation` to one unit and a site-wide loop parks the inverter "
|
||||
"that may well be the one still listening; route `sign_site` to one unit "
|
||||
"and a SITE total pointing the wrong way parks one inverter while the "
|
||||
"rest of the roster goes on pushing the same way - and this line goes red",
|
||||
_routed == {"device": "inverter-a", "supervised": "inverter-a",
|
||||
"failsafe": "inverter-a", "maintenance": "inverter-a",
|
||||
"loop": ACTUATOR_SITE, "peak": ACTUATOR_SITE,
|
||||
"arbitrage": ACTUATOR_SITE, "safety": ACTUATOR_SITE,
|
||||
"circulation": ACTUATOR_SITE})
|
||||
"circulation": ACTUATOR_SITE, "sign_site": ACTUATOR_SITE})
|
||||
check("...and the roster it was restored to is the shipped one, so nothing "
|
||||
"below inherits a two-inverter Controller",
|
||||
c_src.units == (app_main.UNIT_A,) and len(c_src.inverters) == 1)
|
||||
@@ -2716,7 +2743,7 @@ check("...and the roster it was restored to is the shipped one, so nothing "
|
||||
# actuator as a LITERAL - `actuator=self.actuator_of('<source>')` - so the
|
||||
# literal is simply required to EQUAL the source the claim is filed under. That
|
||||
# is what makes "a mis-typed `actuator_of(...)` goes red" a true sentence about
|
||||
# all nine rather than about the three a fixture happens to reach.
|
||||
# all ten rather than about the three a fixture happens to reach.
|
||||
|
||||
|
||||
def append_actuator(node):
|
||||
@@ -2765,16 +2792,16 @@ _unit_sources_unrouted = [
|
||||
if CLAIM_SCOPE.get(r[0]) == SCOPE_UNIT and "," not in r[1]]
|
||||
print(f" {len(_direct)} direct appends, each read at its own line: "
|
||||
+ ", ".join(f"main.py:{ln} {s} -> {a}" for s, a, ln in _routing))
|
||||
check("all NINE of `Controller.cycle()`'s DIRECT appends route through "
|
||||
check("all TEN of `Controller.cycle()`'s DIRECT appends route through "
|
||||
"`self.actuator_of(<string literal>)`, so this scan can read the routing "
|
||||
"of EVERY one of them. An append that computed its actuator, or omitted "
|
||||
"the argument, or hand-wrote a string, fails HERE rather than being "
|
||||
"silently skipped - which is how a scan like this goes quietly vacuous, "
|
||||
"and 10f is in this file because that already happened once",
|
||||
len(_direct) == 9
|
||||
len(_direct) == 10
|
||||
and all(a is not None and a.startswith("self.actuator_of('")
|
||||
for _s, a, _ln in _routing))
|
||||
check("⚠️ AND AT EVERY ONE OF THE NINE THE LITERAL IT ROUTES THROUGH IS THE "
|
||||
check("⚠️ AND AT EVERY ONE OF THE TEN THE LITERAL IT ROUTES THROUGH IS THE "
|
||||
"SOURCE THE CLAIM IS FILED UNDER. THIS is the line a mis-typed "
|
||||
"`actuator_of(...)` at a call site goes red on - all nine of them, on "
|
||||
"the line the typo is written, at every roster, INCLUDING the six "
|
||||
@@ -2788,8 +2815,11 @@ check("⚠️ AND EVERY PER-INVERTER APPEND NAMES THE INVERTER IT IS ABOUT. "
|
||||
"site-scoped sources and is the whole defect for a per-inverter one: a "
|
||||
"`device` limit built inside the roster loop and routed without `inv` "
|
||||
"files inverter B's rating on inverter A, where it binds the wrong "
|
||||
"share. Five of the nine appends are SCOPE_UNIT - `device`, "
|
||||
"`supervised`, `failsafe` and maintenance's two - and all five pass one",
|
||||
"share. Five of the ten appends are SCOPE_UNIT - `device`, "
|
||||
"`supervised`, `failsafe` and maintenance's two - and all five pass one. "
|
||||
"SAFETY-30's `sign_site` is deliberately NOT one of them: it is filed on "
|
||||
"the site, beside `circulation`, because the number that tripped it is "
|
||||
"the site target",
|
||||
_unit_sources_unrouted == []
|
||||
and len([r for r in _routing
|
||||
if CLAIM_SCOPE.get(r[0]) == SCOPE_UNIT]) == 5)
|
||||
@@ -2844,13 +2874,15 @@ check("⚠️ AND THE RATING LIMITS ARE FILED ONCE PER INVERTER, ON ITS OWN "
|
||||
("loop", ACTUATOR_SITE), ("supervised", "inverter-a"),
|
||||
("supervised", "inverter-b")])
|
||||
check("...and naming those three is not an accident of this fixture but the "
|
||||
"reason the static pin exists - six of the nine sources need a state "
|
||||
"reason the static pin exists - SEVEN of the ten sources need a state "
|
||||
"no check in this file reaches. SAFETY-31's `circulation` is one of the "
|
||||
"six: it is filed only while the site is MEASURED to be circulating, "
|
||||
"which no fixture here is",
|
||||
"seven: it is filed only while the site is MEASURED to be circulating, "
|
||||
"which no fixture here is. SAFETY-30's `sign_site` is another, and it "
|
||||
"needs TWO states at once - a roster of two AND the site's total command "
|
||||
"standing opposed to the meter for its whole window",
|
||||
{c.source for c in _cl2}
|
||||
== CLAIM_SOURCES - {"failsafe", "safety", "maintenance", "peak",
|
||||
"arbitrage", "circulation"})
|
||||
"arbitrage", "circulation", "sign_site"})
|
||||
# ⚠️ AND NOW THE HALF THAT WAS EVIDENCE-SHAPED AND OBSERVED NOTHING. The three
|
||||
# checks above grade WHICH ACTUATOR each claim lands on. They say nothing about
|
||||
# WHOSE NUMBERS the bound is built from - and those are two different defects
|
||||
|
||||
@@ -353,6 +353,64 @@ check("...and it is refused with maintenance_enabled off, as shipped",
|
||||
base(max_w=2000, maintenance_charge_w=2500,
|
||||
maintenance_enabled=False), -5000, 5000), "THE CEILING WINS"))
|
||||
|
||||
# ⚠️ MAINT-05: AND AT TWO PACKS IT IS THE WEAKEST CAP, NOT THE FIRST ENTRY'S.
|
||||
# The comment this replaces in validate.py said, in as many words, that it took
|
||||
# the FIRST unit's cap because there was exactly one `Maintenance` and it could
|
||||
# only ever recalibrate `inverters[0]` - and that "when `maint_unit` stops being
|
||||
# `inverters[0]`, this line moves with it". It has. Every pack is now
|
||||
# recalibrated on its own schedule, so the shaping claim can be filed on any of
|
||||
# them and the cap that contradicts it first is the smallest.
|
||||
#
|
||||
# ⚠️ THE FIXTURE'S TWO CAPS ARE DELIBERATELY DIFFERENT AND THE RATE SITS
|
||||
# BETWEEN THEM. Two equal caps could not tell "grades the first" from "grades
|
||||
# the smallest", and a rate above both would be refused by either rule - so
|
||||
# 3000 W against caps of 5000 W and 2000 W is the one arrangement where the old
|
||||
# answer and the new one disagree. ⚠️ 2000 W for the second pack is a
|
||||
# HYPOTHESIS: inverter B does not physically exist and nothing here is measured
|
||||
# from one.
|
||||
def _roster(a_max, b_max, **over):
|
||||
o = base(**over)
|
||||
for k in ("setpoint_entity", "soc_entity", "batt_entity", "max_w"):
|
||||
o.pop(k, None)
|
||||
o["inverters"] = [
|
||||
dict(name="inverter-a", setpoint_entity="number.sp_a",
|
||||
soc_entity="sensor.soc_a", batt_entity="sensor.batt_a",
|
||||
max_w=a_max),
|
||||
dict(name="inverter-b", setpoint_entity="number.sp_b",
|
||||
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b",
|
||||
max_w=b_max)]
|
||||
return o
|
||||
|
||||
|
||||
_two = _roster(5000, 2000, maintenance_charge_w=3000, maintenance_discharge_w=1000,
|
||||
sign_disagree_w=300, unit_sign_disagree_w=300)
|
||||
_p_two = [p for p in validate_startup_config(_two, -5000, 5000)
|
||||
if "maintenance_charge_w" in p]
|
||||
print(f" 5000 W and 2000 W packs, charge 3000 W -> {_p_two}")
|
||||
check("⚠️ A CHARGE RATE THE SMALLEST PACK CANNOT TAKE IS REFUSED, even though "
|
||||
"the FIRST pack could. Before MAINT-05 the second pack was never "
|
||||
"recalibrated, so its cap could not contradict anything; it is now, and "
|
||||
"its cheap-window charge would ask for hi=-3000 against lo=-2000 - the "
|
||||
"`lo > hi` contradiction, 0 W, on the pack nobody was watching",
|
||||
len(_p_two) == 1 and why(_p_two, "max_w (inverter-b) is 2000 W"))
|
||||
check("...and the message names the pack the number came off, not the first "
|
||||
"entry - an operator told to lower a number on the wrong device is being "
|
||||
"sent to the wrong device by the message that exists to stop that",
|
||||
not why(_p_two, "max_w (inverter-a)"))
|
||||
check("...while the same rate against two packs that can both take it starts, "
|
||||
"so this is a comparison and not a blanket refusal of rosters",
|
||||
[p for p in validate_startup_config(
|
||||
_roster(5000, 4000, maintenance_charge_w=3000,
|
||||
maintenance_discharge_w=1000, sign_disagree_w=300,
|
||||
unit_sign_disagree_w=300), -5000, 5000)
|
||||
if "maintenance_charge_w" in p] == [])
|
||||
check("...and at a ROSTER OF ONE `min()` over one cap is that cap: the same "
|
||||
"message, the same boundary, the same refusal the flat config always got",
|
||||
why(validate_startup_config(base(max_w=2000, maintenance_charge_w=2500),
|
||||
-5000, 5000), "THE CEILING WINS")
|
||||
and validate_startup_config(base(max_w=2000, maintenance_charge_w=2000),
|
||||
-5000, 5000) == [])
|
||||
|
||||
# ⚠️ THE SIBLING, CHECKED RATHER THAN ASSUMED. The shaping is NOT symmetric:
|
||||
# drain files Claim.set at P_MAINTENANCE and owns the actuator, so the ceiling
|
||||
# CLAMPS it (+2000 W) instead of contradicting it, and the arbiter's explain()
|
||||
@@ -523,9 +581,26 @@ check("...and the message explains it would read as a trip, not a mistake",
|
||||
# check below.
|
||||
check("the smallest sane max_w still starts",
|
||||
validate_startup_config(base(max_w=1, sign_disagree_w=0.5,
|
||||
unit_sign_disagree_w=0.5,
|
||||
maintenance_charge_w=1), -5000, 5000) == [])
|
||||
check("...but that same 1 W ceiling with the DEFAULT sign threshold is refused",
|
||||
why(validate_startup_config(base(max_w=1), -5000, 5000), "never fire"))
|
||||
# ⚠️ SAFETY-30 ADDED A SECOND WAY TO DISARM A SIGN WATCHDOG BY CONFIGURATION,
|
||||
# and the fixture above now has to name BOTH thresholds - which is the check
|
||||
# doing its job rather than a bookkeeping edit. `unit_sign_disagree_w` bounds a
|
||||
# unit's own SHARE, which the same `supervised` claim holds at +-max_w, so at or
|
||||
# above the ceiling it is unsatisfiable by construction exactly as
|
||||
# `sign_disagree_w` is. Refused even at the shipped roster of one, where this
|
||||
# watchdog is not armed: a config that cannot work is refused when it is
|
||||
# written, not on the day somebody adds a second inverter.
|
||||
check("...and the per-inverter threshold has the same rule, named separately "
|
||||
"so an operator is told WHICH watchdog they disarmed",
|
||||
why(validate_startup_config(base(max_w=1, sign_disagree_w=0.5,
|
||||
maintenance_charge_w=1), -5000, 5000),
|
||||
"unit_sign_disagree_w"))
|
||||
check("...and one watt under that ceiling is reachable, so accepted",
|
||||
validate_startup_config(base(max_w=2000, unit_sign_disagree_w=1999),
|
||||
-5000, 5000) == [])
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("what must NOT be refused - a validator that fires on trivia gets deleted")
|
||||
@@ -753,6 +828,97 @@ check("...and MaintConfig's dataclass defaults carry no numeric literal either "
|
||||
not re.search(r"^\s*(charge_w|discharge_w):\s*float\s*=\s*-?\d",
|
||||
_srcs["maintenance.py"], re.M))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("SPIKE-04a: inverter B's documented rating, and the provenance beside it")
|
||||
# ⚠️ WHY A DOCUMENTATION CARD LEFT A CHECK BEHIND. Inverter B's rating was
|
||||
# written down in THREE places - config.yaml's commented roster example,
|
||||
# DOCS.md's, and tools/supervisor_shape_probe.py's "a blob an operator would
|
||||
# POST" - as 3000 W, a figure nobody had measured, read off a datasheet, or
|
||||
# sourced at all. It was wrong: SPIKE-04a (2026-09-04) identified inverter B
|
||||
# from the owner's model number and serial as a GoodWe GW5048D-ES rated 4600 W
|
||||
# on the battery path. Three transcriptions of one number drifting away from
|
||||
# the truth together is this repo's recurring defect in its plainest form, and
|
||||
# correcting them once WITHOUT PINNING THEM buys nothing: the next editor
|
||||
# touches one of the three and the other two stay wrong, silently.
|
||||
#
|
||||
# ⚠️ AND THE PROVENANCE IS GRADED, NOT ONLY THE VALUE, WHICH IS THE HALF THAT
|
||||
# MATTERS. 4600 W IS FROM A DATASHEET AND IS NOT A MEASUREMENT. The datasheet
|
||||
# prints it under BATTERY INPUT DATA, so it is probably DC, while `max_w` is
|
||||
# graded against 0x0518 - the inverter's own AC power - which would put the AC
|
||||
# ceiling nearer 4324 W. An editor who tidies that caveat away leaves a paper
|
||||
# number reading as an observation of hardware that does not exist yet, and
|
||||
# THAT is the failure this card exists to prevent. So the caveat is what these
|
||||
# checks reach for; a check that graded 4600 alone would watch the value and
|
||||
# miss the lie.
|
||||
#
|
||||
# ⚠️ WHAT THIS DELIBERATELY DOES NOT GRADE: the test fixtures. Several files
|
||||
# build a second inverter at 3000 W on purpose, because the property those
|
||||
# checks consume is that B's rating is UNMISTAKABLY not A's, and the real pair
|
||||
# (5000/4600) is a 400 W gap - narrower than `slew_w`. Those are illustrative,
|
||||
# they say so at the line, and they are not statements of B's rating. The three
|
||||
# sites below are the ones that ARE such statements.
|
||||
_HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
_docs_txt = open(os.path.join(_HERE, "DOCS.md"), encoding="utf-8").read()
|
||||
_probe_txt = open(os.path.join(_HERE, "tools", "supervisor_shape_probe.py"),
|
||||
encoding="utf-8").read()
|
||||
|
||||
# One regex per site, each anchored on something only THAT site has, so a match
|
||||
# cannot silently wander into a neighbouring blob. The probe's anchor is the
|
||||
# operator blob's real entity name: its section D refusal entries use
|
||||
# `number.b` and one of them carries a deliberate 9999, so an anchor loose
|
||||
# enough to reach them would grade the wrong dict and still look green.
|
||||
_b_rating = {
|
||||
"config.yaml": re.search(
|
||||
r"#\s+- name: inverter-b\b(?:[^\n]*\n)*?\s*#\s+max_w:\s*(\d+)", _txt),
|
||||
"DOCS.md": re.search(
|
||||
r"^ - name: inverter-b\b(?:[^\n]*\n)*?^ max_w:\s*(\d+)",
|
||||
_docs_txt, re.M),
|
||||
"supervisor_shape_probe.py": re.search(
|
||||
r'"name": "inverter-b",\s*"setpoint_entity": "number\.goodwe_b_setpoint_w"'
|
||||
r'(?:[^}]*?)"max_w":\s*(\d+)', _probe_txt),
|
||||
}
|
||||
check(f"all three documented rosters were FOUND "
|
||||
f"{ {k: bool(v) for k, v in _b_rating.items()} } - a regex that matches "
|
||||
"nothing is a green check that read nothing",
|
||||
all(_b_rating.values()))
|
||||
# ⚠️ THE `len(...) == 3` IS NOT DECORATION. Without it a regex that stopped
|
||||
# matching would shrink this dict, and "all the values agree" would go GREEN on
|
||||
# the two sites that were still read - a check whose data no longer reaches the
|
||||
# failure it names, which is the exact fault this whole section is about.
|
||||
_b_vals = {k: int(m.group(1)) for k, m in _b_rating.items() if m}
|
||||
check(f"...and all three state the SAME rating for inverter B {_b_vals}",
|
||||
len(_b_vals) == 3 and len(set(_b_vals.values())) == 1)
|
||||
check(f"...and it is 4600 W - the GW5048D-ES datasheet figure, not the 3000 W "
|
||||
f"hypothesis that predated the unit being identified {_b_vals}",
|
||||
len(_b_vals) == 3 and set(_b_vals.values()) == {4600})
|
||||
|
||||
# The provenance triple. Each site must still say WHERE 4600 came from, that it
|
||||
# is graded against an AC register, and what the DC-vs-AC ambiguity does to it -
|
||||
# the last carried by the 4324 W figure, which is the one marker that cannot
|
||||
# survive a careless "it's 4600 now, done" rewrite.
|
||||
#
|
||||
# ⚠️ SEARCHED IN A WINDOW AROUND THE ROSTER, NOT OVER THE WHOLE FILE, AND THE
|
||||
# FIRST VERSION OF THIS CHECK DID THE LATTER. `0x0518` already appeared once in
|
||||
# config.yaml and once in DOCS.md before this card, for unrelated reasons - so a
|
||||
# whole-file `"0x0518" in src` was GREEN on those two files no matter what
|
||||
# happened next to inverter B's rating. That is a check whose data cannot reach
|
||||
# the failure it names, in the same file that exists to complain about them.
|
||||
# The window is the text either side of the roster match, so deleting the caveat
|
||||
# beside the number goes red even where the same word survives elsewhere.
|
||||
_sites = {"config.yaml": _txt, "DOCS.md": _docs_txt,
|
||||
"supervisor_shape_probe.py": _probe_txt}
|
||||
_MARKERS = ("datasheet", "0x0518", "4324")
|
||||
_prov = {}
|
||||
for _name, _src in _sites.items():
|
||||
_m = _b_rating[_name]
|
||||
_win = _src[max(0, _m.start() - 2500):_m.end() + 2500].lower() if _m else ""
|
||||
_prov[_name] = {k: k in _win for k in _MARKERS}
|
||||
for _name, _got in sorted(_prov.items()):
|
||||
check(f"{_name} still carries B's provenance WITHIN 2500 chars of the "
|
||||
f"roster - the datasheet it came from, the 0x0518 it is graded "
|
||||
f"against, and the 4324 W the DC reading would make it {_got}",
|
||||
all(_got.values()))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print()
|
||||
if fails:
|
||||
|
||||
@@ -401,10 +401,19 @@ print("controller and the first thing an operator will try")
|
||||
|
||||
|
||||
class _MemStore:
|
||||
"""A Store that keeps its dict across "restarts", like the real file does."""
|
||||
"""A Store that keeps its dict across "restarts", like the real file does.
|
||||
|
||||
⚠️ SEEDED FROM `store.DEFAULTS`, NOT FROM A LITERAL. `Store.load()` merges
|
||||
that dict over whatever is on disk, so a fake that hand-listed three keys
|
||||
answered `None` where the real store answers a default - and a check reading
|
||||
"this latch was never written" then could not tell an absent key from a
|
||||
False one. It is also a place to drift: SAFETY-31 and SAFETY-30 both added
|
||||
flat pairs, and neither would have appeared here.
|
||||
"""
|
||||
|
||||
def __init__(self):
|
||||
self.data = {"phase": "idle", "sign_tripped": False, "sign_reason": ""}
|
||||
from app.store import DEFAULTS as _SDEF
|
||||
self.data = dict(_SDEF)
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
@@ -789,9 +798,18 @@ print(" circulation the allocator NEVER COMMANDED")
|
||||
|
||||
from app.inverter import Inverter # noqa: E402
|
||||
|
||||
# ⚠️ INVERTER B DOES NOT PHYSICALLY EXIST - it is ~10 days out and SPIKE-04
|
||||
# measures it. Its rating here is a HYPOTHESIS, named as one, exactly as
|
||||
# test_peakguard.py's helper names its own.
|
||||
# ⚠️ INVERTER B DOES NOT PHYSICALLY EXIST - it is ~8 days out (2026-09-04) and
|
||||
# the bench half of SPIKE-04 measures it.
|
||||
# ⚠️ SPIKE-04a (2026-09-04) ESTABLISHED B'S REAL RATING FROM ITS DATASHEET:
|
||||
# a GoodWe GW5048D-ES, serial `55048ESU22AW0992`, 4600 W on the battery path
|
||||
# (goodwe/NOTES.md §1.1b). THIS FIXTURE DELIBERATELY DOES NOT USE IT. 3000 W is
|
||||
# kept because the only property these checks consume is that B's number is
|
||||
# UNMISTAKABLY not A's, and the real pair is 5000/4600 - a 400 W gap, narrower
|
||||
# than `slew_w` and inside the range where an off-by-one-unit bug and ordinary
|
||||
# control arithmetic produce indistinguishable numbers. Collapsing the fixture
|
||||
# onto the real values would cost these checks their separating power to buy
|
||||
# realism they do not use. So: ILLUSTRATIVE, NOT B'S RATING, and not a
|
||||
# placeholder for it either - the placeholder era ended on 2026-09-04.
|
||||
B_RATING_HYPOTHESIS = 3000.0
|
||||
|
||||
|
||||
@@ -1105,6 +1123,701 @@ check("⚠️ AND THE 'HAS A HUMAN SEEN THIS' FLAG IS CLEARED WITH IT. Left "
|
||||
_cc._circ_announced is False)
|
||||
|
||||
|
||||
|
||||
print()
|
||||
print("=" * 72)
|
||||
print("SAFETY-30: at two inverters the sign check is TWO questions, not one")
|
||||
print("=" * 72)
|
||||
# ⚠️ READ THIS BEFORE ADDING A CHECK HERE. Half of this card was already built
|
||||
# and it is NOT the half below. DEV-02 shipped the PER-INSTANCE half: each
|
||||
# `Inverter` owns its own `SignWatchdog`, latched under its own namespaced store
|
||||
# keys, and a trip on B no longer latches A. test_inverter.py part 3 grades
|
||||
# that; nothing here re-tests it.
|
||||
#
|
||||
# What is graded here is THE COMPARISON ITSELF. Before this card every unit's
|
||||
# detector was handed `self.grid`. There is ONE P1, so at N>=2 that is a number
|
||||
# this controller put on ONE actuator, graded against a measurement that answers
|
||||
# for ALL of them - wrong in both directions: a FALSE trip when a sibling
|
||||
# accounts for the meter, and a MISSED one when a sibling MASKS a unit that
|
||||
# really is reversed. The fix is two comparisons, and they are two different
|
||||
# faults: each unit against ITS OWN measured power, and the SUM of the standing
|
||||
# commands against the meter.
|
||||
#
|
||||
# ⚠️ AND IT IS NOT SAFETY-31, WHICH IS THE SECTION ABOVE. `circulation.py`
|
||||
# compares the units AGAINST EACH OTHER and catches two inverters pushing
|
||||
# THROUGH each other, which nets to zero at the meter. This compares each unit
|
||||
# against ITS OWN COMMAND and catches a unit not doing what it was told. They
|
||||
# overlap in exactly one scenario - a unit reversing while its sibling pulls the
|
||||
# other way - and part 4 below asserts what each one concludes there, because
|
||||
# two guards that overlap without saying so is how a false-alarm generator gets
|
||||
# built.
|
||||
|
||||
from app.control import Tuning as _Tuning # noqa: E402
|
||||
from app.watchdog import ( # noqa: E402
|
||||
AGAINST_METER, AGAINST_OWN_POWER, SIGN_OPTION_DEFAULTS, disagrees,
|
||||
)
|
||||
|
||||
print()
|
||||
print("1. ONE predicate, TWO second terms - and the trip sentence says which")
|
||||
# ⚠️ THE ARITHMETIC IS UNCHANGED AND THAT IS THE POINT: `disagrees()` was not
|
||||
# split in two. What moved is a PARAMETER NAME - `grid_w` became `against_w` -
|
||||
# because what the command is opposed TO is now the caller's decision. A second
|
||||
# copy of a safety predicate is one copy plus a future disagreement about what
|
||||
# the check means (see `loop_is_following()`), so there is still exactly one.
|
||||
_scfg = SignWatchdogConfig(min_w=300.0, hold_s=180.0)
|
||||
_ucfg = SignWatchdogConfig(
|
||||
min_w=float(SIGN_OPTION_DEFAULTS["unit_sign_disagree_w"]),
|
||||
hold_s=float(SIGN_OPTION_DEFAULTS["unit_sign_disagree_s"]))
|
||||
check("the same call that means 'commanded -1000 W into a +1500 W import' "
|
||||
"means 'commanded -1000 W while measuring +1500 W of discharge' when the "
|
||||
"caller hands it a unit's own power - one function, two questions",
|
||||
disagrees(-1000.0, 1500.0, True, _scfg) is True)
|
||||
check("...and every gate still binds on the second term whatever it is: a "
|
||||
"250 W reading does not qualify against a 300 W gate",
|
||||
disagrees(-1000.0, 250.0, True, _scfg) is False)
|
||||
check("...nor does a unit sitting at zero, which is a REFUSED command and not "
|
||||
"a reversed one - the distinction the module docstring makes about a "
|
||||
"battery declining a discharge, now read of the unit's own sensor",
|
||||
disagrees(1500.0, 0.0, True, _ucfg) is False)
|
||||
|
||||
_wd_site = SignWatchdog(_scfg)
|
||||
_wd_unit = SignWatchdog(_ucfg, against=AGAINST_OWN_POWER)
|
||||
for _t in range(0, 400, 5):
|
||||
_wd_site.evaluate(-1000.0, 1500.0, True, T0 + timedelta(seconds=_t))
|
||||
_wd_unit.evaluate(-1000.0, 1500.0, True, T0 + timedelta(seconds=_t))
|
||||
print(f" site: {_wd_site.reason!r}")
|
||||
print(f" unit: {_wd_unit.reason!r}")
|
||||
check("⚠️ THE SITE INSTANCE'S SENTENCE IS BYTE-IDENTICAL TO THE ONE THAT "
|
||||
"SHIPPED. It is what an operator reads on the status page, what goes in "
|
||||
"the action log and what is persisted to /data/state.json, so it is "
|
||||
"asserted against the literal rather than against a format string",
|
||||
_wd_site.reason == (
|
||||
"SIGN_DISAGREEMENT: commanded -1000 W against a meter reading "
|
||||
"+1500 W for 180 s continuously (limits: both over 300 W, held over "
|
||||
"180 s)"))
|
||||
check("...and the per-unit instance names what it ACTUALLY compared instead. "
|
||||
"'against a meter reading' there would be a false statement about which "
|
||||
"instrument produced the evidence, on the one line somebody woken by "
|
||||
"this alarm reads first",
|
||||
AGAINST_OWN_POWER in _wd_unit.reason
|
||||
and AGAINST_METER not in _wd_unit.reason
|
||||
and "+1500 W" in _wd_unit.reason)
|
||||
# ⚠️ `arm()` IS CONFIGURATION AND MUST NOT BE STATE. `Controller.cycle()` calls
|
||||
# it on EVERY cycle, so a version that cleared `disagree_since` there would
|
||||
# restart the window every cycle, never accumulate a hold, and leave the check
|
||||
# permanently green with nothing saying so. Driven rather than argued: open a
|
||||
# window, re-arm mid-episode, and see the window still standing.
|
||||
_rearm = SignWatchdog(_ucfg, against=AGAINST_OWN_POWER)
|
||||
_rearm.evaluate(-1000.0, 1500.0, True, T0)
|
||||
_rearm.evaluate(-1000.0, 1500.0, True, T0 + timedelta(seconds=5))
|
||||
_rearm.arm(_ucfg, AGAINST_OWN_POWER)
|
||||
check("re-arming mid-episode leaves the window exactly where it was",
|
||||
_rearm.disagree_since == T0)
|
||||
for _t in range(10, 200, 5):
|
||||
_rearm.arm(_ucfg, AGAINST_OWN_POWER)
|
||||
_rearm.evaluate(-1000.0, 1500.0, True, T0 + timedelta(seconds=_t))
|
||||
check("...so a detector re-armed on every one of 38 cycles still trips at its "
|
||||
"85 s hold, which is what says `arm()` did not quietly disarm it",
|
||||
_rearm.tripped)
|
||||
|
||||
print()
|
||||
print("2. CFG-03: config.yaml is the source of truth and there is ONE copy")
|
||||
_sign_from_yaml = {k: int(v) for k, v in
|
||||
_re.findall(r"^ ((?:unit|site)_sign_disagree_\w+):\s*(\d+)\s*$",
|
||||
_cfg_opts, _re.M)}
|
||||
print(f" config.yaml options: {_sign_from_yaml}")
|
||||
print(f" SIGN_OPTION_DEFAULTS: {SIGN_OPTION_DEFAULTS}")
|
||||
check("all four new options are declared in config.yaml's options: block and "
|
||||
"the in-code mirror agrees key for key and value for value - the "
|
||||
"Dockerfile does not put config.yaml in the image, so the running add-on "
|
||||
"cannot read it and this is where the two can drift",
|
||||
_sign_from_yaml == SIGN_OPTION_DEFAULTS and len(_sign_from_yaml) == 4)
|
||||
_sign_bounds = {m[0]: (int(m[1]), int(m[2])) for m in
|
||||
_re.findall(r"^ ((?:unit|site)_sign_disagree_\w+):"
|
||||
r"\s*int\((\d+),(\d+)\)\s*$",
|
||||
_cfg_schema, _re.M)}
|
||||
print(f" schema bounds: {_sign_bounds}")
|
||||
check("...and ALL FOUR have a schema range, so the Supervisor refuses an "
|
||||
"out-of-range value rather than the add-on discovering it at runtime",
|
||||
set(_sign_bounds) == set(SIGN_OPTION_DEFAULTS))
|
||||
check("the shipped defaults sit inside their own schema ranges",
|
||||
all(_sign_bounds[k][0] <= v <= _sign_bounds[k][1]
|
||||
for k, v in SIGN_OPTION_DEFAULTS.items()))
|
||||
check("⚠️ THE THRESHOLD IS `saturation_w / 2`, WHICH IS WHERE THE CONTROL LAW "
|
||||
"ITSELF ALREADY DRAWS THE LINE. This check gates on BOTH sides, and the "
|
||||
"two are OPPOSED, so the smallest command-versus-power gap it can ever "
|
||||
"see is 2 x min_w. At 250 W that is exactly the 500 W at which "
|
||||
"`compute()`'s own anti-windup test concludes the inverter is not "
|
||||
"following and freezes the integrator - so this watchdog cannot fire on "
|
||||
"a divergence the shipped loop calls ordinary tracking, and the two "
|
||||
"guards meet at a number instead of overlapping in a band nobody drew",
|
||||
SIGN_OPTION_DEFAULTS["unit_sign_disagree_w"] * 2
|
||||
== _Tuning().saturation_w)
|
||||
check("...and the window clears its three bounds: above the firmware's own "
|
||||
"30 s link veto (`inverter.LINK_STALE_S` - inside it, a unit not "
|
||||
"executing its share is a LINK fault the add-on already answers by "
|
||||
"dropping it from the split), and UNDER HALF the 180 s the site check "
|
||||
"takes, because the per-unit conclusion needs nothing to net out before "
|
||||
"it is complete",
|
||||
SIGN_OPTION_DEFAULTS["unit_sign_disagree_s"] > LINK_STALE_S
|
||||
and SIGN_OPTION_DEFAULTS["unit_sign_disagree_s"] < 180 / 2)
|
||||
check("⚠️ AND NEITHER IS A ROUND NUMBER. 250 W is read off `saturation_w`; "
|
||||
"85 s is 8.5x the worst legitimate opposition 1890 two-inverter runs "
|
||||
"produce (10.0 s) and 2.8x the firmware veto. 60, 75, 90, 100, 120, 180 "
|
||||
"and 300 are all values a guess would have landed on",
|
||||
SIGN_OPTION_DEFAULTS["unit_sign_disagree_s"]
|
||||
not in (30, 60, 75, 90, 100, 120, 180, 300))
|
||||
|
||||
# ⚠️ AND THE SITE PAIR IS TWO DECISIONS, NOT ONE, WHICH IS WHY BOTH ARE PINNED.
|
||||
# The THRESHOLD is carried from the shipped pair because its argument is about
|
||||
# the meter's noise floor and the deadband - a property of ONE P1 and of
|
||||
# `Tuning.deadband_w`, neither of which the roster touches. The WINDOW is NOT
|
||||
# carried, because the transient it rejects is the loop crossing zero across a
|
||||
# rail that IS the roster sum: measured at 110 s with one inverter and 215 s
|
||||
# with two, on the same stimuli, against a 180 s hold. That is a carried number
|
||||
# justified and a carried number refused, in the same pair.
|
||||
check("the SITE threshold is the shipped one, carried - the noise argument "
|
||||
"behind 300 W is about the meter and the deadband, and a second inverter "
|
||||
"changes neither",
|
||||
SIGN_OPTION_DEFAULTS["site_sign_disagree_w"] == 300)
|
||||
check("⚠️ ...AND THE SITE WINDOW IS LONGER THAN THE SHIPPED 180 s, WHICH IS THE "
|
||||
"MEASUREMENT REFUSING TO BE CARRIED. At two inverters the worst "
|
||||
"legitimate opposition the rig produces is 215.0 s - reachable at "
|
||||
"`gain: 0.05`, `slew_w: 50` and a 2.2 kW load reversal, all inside what "
|
||||
"config.yaml accepts - so 180 s would have shipped a false trip on the "
|
||||
"check with the best record in the safety table. 325 s is 1.51x that",
|
||||
SIGN_OPTION_DEFAULTS["site_sign_disagree_s"] > 215.0
|
||||
and SIGN_OPTION_DEFAULTS["site_sign_disagree_s"] < 215.0 * 2)
|
||||
check("...and it is still inside the 900 s quarter that bills the capacity "
|
||||
"tariff, and inside every episode the 2026-08-20 fault day contains - "
|
||||
"its four clusters run 16, 30, 77 and 77 minutes",
|
||||
SIGN_OPTION_DEFAULTS["site_sign_disagree_s"] < 900
|
||||
and SIGN_OPTION_DEFAULTS["site_sign_disagree_s"] < 16 * 60)
|
||||
check("...and it is deliberately not 300 or 360, the two round numbers next to "
|
||||
"it",
|
||||
SIGN_OPTION_DEFAULTS["site_sign_disagree_s"] not in (300, 360, 600, 900))
|
||||
|
||||
print()
|
||||
print("3. AC 1: ONE unit drives the wrong way, and ONLY that unit trips")
|
||||
# ⚠️ THE PLANT IS MODELLED AND SAYS SO. `_SignHass` is two inverters that obey
|
||||
# INSTANTLY - no ramp, no lag - and one meter that is `load - sum(measured)`.
|
||||
# That is deliberately not a claim about transients: the worst legitimate
|
||||
# opposition a real ramp and lag can produce is measured on admin/goodwe's
|
||||
# two-master rig, over 1890 closed-loop runs, and recorded in
|
||||
# DECISIONS/SAFETY-30-per-unit-sign.md. What this fixture is for is the
|
||||
# ATTRIBUTION - which detector concludes what, from which instrument - and for
|
||||
# that an instant plant is the honest model, because it removes the one
|
||||
# mechanism that could make a unit look reversed without being reversed.
|
||||
|
||||
|
||||
class _SignHass(_Hass):
|
||||
"""Two inverters, one meter, and a chosen subset that does the OPPOSITE.
|
||||
|
||||
`reversed_units` are roster indices whose measured power is the NEGATION of
|
||||
what this controller told them - HW-01's wedged power stage, an inverted
|
||||
driver, a unit executing a stale share backwards. Everything else obeys.
|
||||
"""
|
||||
|
||||
def __init__(self, load_w=2000.0, reversed_units=()):
|
||||
super().__init__()
|
||||
self.load_w = float(load_w)
|
||||
self.reversed_units = set(reversed_units)
|
||||
self.ctrl = None
|
||||
|
||||
def measured(self):
|
||||
if self.ctrl is None:
|
||||
return [0.0, 0.0]
|
||||
out = []
|
||||
for i, inv in enumerate(self.ctrl.inverters):
|
||||
w = inv.last_write if inv.last_write is not None else inv.target
|
||||
w = float(w or 0.0)
|
||||
out.append(-w if i in self.reversed_units else w)
|
||||
return out
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
m = self.measured() + [0.0, 0.0]
|
||||
return {"sensor.grid": self.load_w - sum(m[:2]),
|
||||
"sensor.soc": 50.0, "sensor.soc_b": 50.0,
|
||||
"sensor.batt": m[0], "sensor.batt_b": m[1]}.get(entity)
|
||||
|
||||
|
||||
def _sign_site(hass, store=None, **over):
|
||||
"""A two-inverter Controller, with SAFETY-31 deliberately given a long window.
|
||||
|
||||
⚠️ THE LONG `circulation_hold_s` IS ISOLATION, NOT A CLAIM THAT SAFETY-31 IS
|
||||
SILENT HERE. A unit reversing while its sibling pulls the other way IS
|
||||
circulating power and SAFETY-31 sees it - part 4 asserts exactly that, and
|
||||
what each guard concludes about it. What must not happen is the SITE being
|
||||
stopped by circulation while this section is trying to grade a PER-UNIT
|
||||
attribution, because then every "only B is parked" check below would be
|
||||
measuring the wrong guard.
|
||||
|
||||
⚠️ THE THREE THRESHOLD PAIRS ARE PAIRWISE DISTINCT IN BOTH COORDINATES,
|
||||
AND THAT IS LOAD-BEARING RATHER THAN COSMETIC. This fixture is the only
|
||||
place in the suite where `_arm_sign_watchdogs()` runs at a roster of two, so
|
||||
it is the only place that can see WHICH pair reaches WHICH detector. The
|
||||
first version of it set every hold to 1 s and two of the three magnitude
|
||||
gates to 300 W; a detector armed with the shipped pair, or with the site
|
||||
pair, or with the right magnitude and the wrong hold, then compared EQUAL
|
||||
to the pair it was supposed to have, and the wiring check below would have
|
||||
passed on three of those four arrangements. That is MUTATION.md's third
|
||||
failure mode written into a fixture - a check comparing two things that
|
||||
happen to be equal cannot see the difference it names - and the
|
||||
precondition beside the check is what stops a later edit collapsing them
|
||||
again without a red line.
|
||||
|
||||
Anyone changing a hold here: the PER-UNIT hold is what part 3's trip timing
|
||||
is read against, and the SITE hold must still expire inside `_drive()`'s
|
||||
window (14 cycles x 0.2 s), which part 5 depends on.
|
||||
"""
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": 0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 3,
|
||||
"unit_sign_disagree_w": 250, "unit_sign_disagree_s": 1,
|
||||
"site_sign_disagree_w": 320, "site_sign_disagree_s": 2,
|
||||
"circulation_hold_s": 3600, "auto_start": True}
|
||||
opts.update(over)
|
||||
c = Controller(opts, hass, store if store is not None else _MemStore(),
|
||||
_P(), stop=asyncio.Event())
|
||||
b = Inverter("inverter-b", setpoint_entity="number.sp_b",
|
||||
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b",
|
||||
max_w=B_RATING_HYPOTHESIS, store=c.store)
|
||||
b.dev_min, b.dev_max = -B_RATING_HYPOTHESIS, B_RATING_HYPOTHESIS
|
||||
c.inverters.append(b)
|
||||
c.auto = True
|
||||
for inv in c.inverters:
|
||||
if inv.dev_min is None:
|
||||
inv.dev_min, inv.dev_max = -5000.0, 5000.0
|
||||
hass.ctrl = c
|
||||
return c
|
||||
|
||||
|
||||
async def _drive(c, n=14, dt=0.2, watch=None):
|
||||
seen = []
|
||||
for _ in range(n):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
if watch is not None:
|
||||
seen.append(watch(c))
|
||||
await asyncio.sleep(dt)
|
||||
return seen
|
||||
|
||||
|
||||
async def _one_reversed():
|
||||
hass = _SignHass(load_w=2000.0, reversed_units={1})
|
||||
c = _sign_site(hass)
|
||||
seen = await _drive(c, watch=lambda c: dict(
|
||||
grid=c.grid,
|
||||
stood=[i.last_write if i.last_write is not None else i.target
|
||||
for i in c.inverters],
|
||||
meas=[i.batt for i in c.inverters],
|
||||
a=c.inverters[0].sign_wd.tripped, b=c.inverters[1].sign_wd.tripped,
|
||||
site=c.site_sign_wd.tripped))
|
||||
return c, hass, seen
|
||||
|
||||
|
||||
_c30, _h30, _s30 = asyncio.run(_one_reversed())
|
||||
_a30, _b30 = _c30.inverters
|
||||
|
||||
# ⚠️ THE WIRING PIN FOR AC 5, AND IT IS A DIFFERENT CLAIM FROM EVERY
|
||||
# BEHAVIOURAL CHECK IN THIS SECTION. The rest of part 3 grades what the
|
||||
# detectors CONCLUDED; this grades WHICH THRESHOLDS THEY WERE HANDED, and the
|
||||
# gap between the two was live. Replacing
|
||||
# `arm(self.sign_cfg if one else self.unit_sign_cfg, ...)` with
|
||||
# `arm(self.sign_cfg, ...)` in `Controller._arm_sign_watchdogs()` throws the
|
||||
# re-derived per-unit pair away and arms every unit with SAFETY-02's
|
||||
# meter-facing one - and left ALL 19 FILES GREEN. Nothing at a roster of two
|
||||
# read `inv.sign_wd.cfg` at all; the one place that does is part 7's N=1 arm,
|
||||
# which that edit PRESERVES.
|
||||
#
|
||||
# WHY THE TRIPS BELOW CANNOT CATCH IT, said here because "the suite is green"
|
||||
# and "nothing was wrong" are the two readings this comment exists to separate.
|
||||
# B is reversed at ~2000 W - far over 250 W and far over 300 W - and every hold
|
||||
# in this fixture is short enough to expire inside `_drive()`. A fault that is
|
||||
# big enough and long enough to trip under BOTH pairs is evidence about
|
||||
# neither. Only an equality on the pair itself can tell them apart.
|
||||
#
|
||||
# WHAT THE SURVIVOR COSTS IN THE FIELD, at config.yaml's own defaults: the
|
||||
# per-unit check runs at `sign_disagree_s` 180 s instead of the re-derived 85 s
|
||||
# - 2.1x slower to park a reversed inverter - and its gate moves from 250 W to
|
||||
# 300 W, so a unit reversing a share between the two becomes invisible, while
|
||||
# watchdog.SIGN_OPTION_DEFAULTS, config.yaml and DECISIONS section 3 all go on
|
||||
# describing a pair the running code does not use.
|
||||
_UNIT_PAIR = (250.0, 1.0) # `unit_sign_disagree_w` / `_s` - one per unit
|
||||
_SITE_PAIR = (320.0, 2.0) # `site_sign_disagree_w` / `_s` - one per site
|
||||
_SHIPPED_PAIR = (300.0, 3.0) # `sign_disagree_w` / `_s` - N=1 only
|
||||
_armed = {inv.name: (inv.sign_wd.cfg.min_w, inv.sign_wd.cfg.hold_s)
|
||||
for inv in _c30.inverters}
|
||||
_armed_site = (_c30.site_sign_wd.cfg.min_w, _c30.site_sign_wd.cfg.hold_s)
|
||||
print(f" armed per unit: {_armed}")
|
||||
print(f" armed site: {_armed_site} "
|
||||
f"shipped pair, wanted by NOBODY here: {_SHIPPED_PAIR}")
|
||||
check("PRECONDITION: the three pairs are pairwise distinct IN BOTH "
|
||||
"COORDINATES, so an equality below can fail on the magnitude alone, on "
|
||||
"the hold alone, or on both. This fixture originally gave all three the "
|
||||
"same 1 s hold and two of them the same 300 W gate, and a mis-wiring "
|
||||
"that delivered the right magnitude with the wrong hold would then have "
|
||||
"compared EQUAL to the pair it was supposed to have",
|
||||
len({_UNIT_PAIR, _SITE_PAIR, _SHIPPED_PAIR}) == 3
|
||||
and len({p[0] for p in (_UNIT_PAIR, _SITE_PAIR, _SHIPPED_PAIR)}) == 3
|
||||
and len({p[1] for p in (_UNIT_PAIR, _SITE_PAIR, _SHIPPED_PAIR)}) == 3)
|
||||
check("PRECONDITION: and all three are pairs this Controller actually holds, "
|
||||
"so the literals below are the fixture's own numbers and not three "
|
||||
"constants that agree with nothing. In particular the shipped pair is "
|
||||
"still constructed and still a reachable mis-wiring target",
|
||||
(_c30.unit_sign_cfg.min_w, _c30.unit_sign_cfg.hold_s) == _UNIT_PAIR
|
||||
and (_c30.site_sign_cfg.min_w, _c30.site_sign_cfg.hold_s) == _SITE_PAIR
|
||||
and (_c30.sign_cfg.min_w, _c30.sign_cfg.hold_s) == _SHIPPED_PAIR)
|
||||
check("⚠️ AC 5 WIRING. EVERY per-unit detector on this roster of two is armed "
|
||||
"with the PER-UNIT pair - 250 W / 1 s here, `unit_sign_disagree_w` and "
|
||||
"`unit_sign_disagree_s` in the field. Graded against LITERALS rather "
|
||||
"than against `_c30.unit_sign_cfg`, which cannot tell 'the per-unit "
|
||||
"pair' from 'whatever this Controller was handed'. This is the line that "
|
||||
"goes red when `_arm_sign_watchdogs()` stops choosing between the two "
|
||||
"pairs and hands every unit the site-facing one",
|
||||
len(_armed) == 2 and all(p == _UNIT_PAIR for p in _armed.values()))
|
||||
check("...and the SITE detector is armed with the SITE pair - 320 W / 2 s "
|
||||
"here - which differs from the per-unit pair AND from the shipped pair "
|
||||
"in both coordinates, so this equality is not carried by a number the "
|
||||
"fixture happens to hold twice",
|
||||
_armed_site == _SITE_PAIR)
|
||||
check("...and each detector is pointed at its own INSTRUMENT as well as at its "
|
||||
"own thresholds: the units at their own 0x0518 power, the site at the "
|
||||
"meter. They are two arguments of one call and a pin on one is not a pin "
|
||||
"on the other",
|
||||
all(inv.sign_wd.against == AGAINST_OWN_POWER for inv in _c30.inverters)
|
||||
and _c30.site_sign_wd.against == AGAINST_METER)
|
||||
|
||||
_mid = _s30[3]
|
||||
print(f" cycle 3: stood {[round(x) for x in _mid['stood']]} "
|
||||
f"measured {[round(x) for x in _mid['meas']]} "
|
||||
f"meter {_mid['grid']:+.0f} W")
|
||||
check("PRECONDITION: the stimulus is not vacuous - inverter B really is doing "
|
||||
"the OPPOSITE of what it was told, and inverter A really is obeying. "
|
||||
"Without this line every claim below could be true of a fixture in which "
|
||||
"nothing was reversed",
|
||||
_mid["stood"][1] * _mid["meas"][1] < 0
|
||||
and abs(_mid["meas"][1]) > 250
|
||||
and _mid["stood"][0] * _mid["meas"][0] > 0)
|
||||
check("⚠️ AC 1. THE REVERSED UNIT TRIPS AND ITS SIBLING DOES NOT. The evidence "
|
||||
"is B's own 0x0518 power against B's own share, so it is a fact about B "
|
||||
"and nothing about A - which is what makes parking one of them the right "
|
||||
"remedy rather than an attribution nobody measured",
|
||||
_b30.sign_wd.tripped and not _a30.sign_wd.tripped)
|
||||
check("...and the reason names the instrument, so the operator is sent to the "
|
||||
"right one", AGAINST_OWN_POWER in _b30.sign_wd.reason)
|
||||
print(f" {_b30.sign_wd.reason!r}")
|
||||
# ⚠️ READ OFF THE ALLOCATION RECORD, NOT OFF `Controller.reason`. At a roster
|
||||
# of two `reason` is the SITE resolution's line - "loop -> 2000 W" - because
|
||||
# B's failsafe is a UNIT claim resolved on B's own actuator and never competes
|
||||
# for the site winner. That is the DEV-02 split working, and a check that
|
||||
# grepped the site line for "failsafe" would go green only while the roster was
|
||||
# one. The per-unit record is where the pin is stated, and it names its source.
|
||||
_bplan = [pl for pl in (_c30.allocation.plans if _c30.allocation else ())
|
||||
if pl.unit == "inverter-b"]
|
||||
print(f" allocation: {_c30.allocation.explain()}")
|
||||
print(f" inverter-b plan: {_bplan[0].why if _bplan else '(none)'}")
|
||||
check("...B is commanded 0 W by its OWN `failsafe` claim, named in the "
|
||||
"allocation record, rather than by some other guard happening to stop it",
|
||||
_b30.target == 0.0 and _bplan and "failsafe" in _bplan[0].why)
|
||||
check("...and A IS STILL COMMANDING. One inverter in trouble stops that "
|
||||
"inverter; the site goes on running on the one that works, which is what "
|
||||
"a UNIT-scoped claim buys and what a site-wide stop would have thrown "
|
||||
"away", _a30.target != 0.0)
|
||||
check("...the latch is under B's OWN namespaced key, and A's is untouched",
|
||||
_c30.store.data.get(unit_key("inverter-b", "sign_tripped")) is True
|
||||
and _c30.store.data.get(TRIPPED_KEY) is False)
|
||||
|
||||
print()
|
||||
print("4. AC 2: and it is caught EVEN THOUGH THE METER SAYS EVERYTHING IS FINE")
|
||||
# ⚠️ THIS IS THE CHECK THE WHOLE CARD IS FOR, so it is built the way MUTATION.md
|
||||
# says to build one: the claim is "the new comparison sees what the old one
|
||||
# structurally cannot", and the OLD comparison is RUN, on the same samples, and
|
||||
# its blindness is asserted as its own precondition and PRINTED - not argued.
|
||||
_old_view = [disagrees(s["stood"][1], s["grid"], True, _scfg) for s in _s30]
|
||||
_site_view = [disagrees(sum(s["stood"]), s["grid"], True, _scfg) for s in _s30]
|
||||
print(f" the SHIPPED comparison (B's command vs the meter) was true on "
|
||||
f"{sum(_old_view)} of {len(_old_view)} cycles")
|
||||
print(f" the SITE comparison (sum of commands vs the meter) on "
|
||||
f"{sum(_site_view)} of {len(_site_view)}")
|
||||
check("⚠️ THE COMPARISON THAT SHIPPED IS FALSE ON EVERY SINGLE CYCLE HERE. B is "
|
||||
"commanded to discharge and the house is importing, so B's command and "
|
||||
"the meter AGREE all the way through - the meter cannot tell that the "
|
||||
"watts arriving are inverter A's while B does the opposite. This is not "
|
||||
"a threshold set too high: the summation destroys the evidence and no "
|
||||
"tuning recovers it",
|
||||
not any(_old_view))
|
||||
check("...and the SITE comparison is blind for the same reason, which is why "
|
||||
"it is kept as a SEPARATE question rather than offered as the fix",
|
||||
not any(_site_view))
|
||||
check("...while the shipped SITE watchdog stayed correctly silent, so nothing "
|
||||
"here is a site-level trip wearing a per-unit label",
|
||||
not _c30.site_sign_wd.tripped
|
||||
and _c30.store.data.get("site_sign_tripped") is not True)
|
||||
check("⚠️ AND SAFETY-31 SEES SOMETHING TOO, WHICH IS NOT A DUPLICATE AND IS "
|
||||
"SAID HERE RATHER THAN LEFT FOR SOMEBODY TO DISCOVER. A unit reversing "
|
||||
"while its sibling pulls the other way IS power going round a loop, so "
|
||||
"`circulating_w()` is over its threshold on this fixture - it is only "
|
||||
"the long window this fixture gives it that keeps it from stopping the "
|
||||
"site. The two guards CONCLUDE different things: circulating power is "
|
||||
"defined over the roster and names no offender, while this one names B "
|
||||
"and parks B. Neither is the other with a different threshold",
|
||||
max(circulating_w(s["meas"]) for s in _s30) > _c30.circ_wd.cfg.min_w
|
||||
and not _c30.circ_wd.tripped
|
||||
and _c30.site_circulating_w == 0.0)
|
||||
|
||||
print(f" circulating power over the episode: "
|
||||
f"{[round(circulating_w(s['meas'])) for s in _s30]}")
|
||||
check("...and it falls back to ZERO the moment B is parked, which is the "
|
||||
"remedy working rather than the sensor going quiet: a unit held at 0 W "
|
||||
"cannot be half of a loop. It is asserted on the EPISODE rather than on "
|
||||
"the end state for exactly that reason",
|
||||
_s30[-1]["meas"][1] == 0.0)
|
||||
|
||||
print()
|
||||
print("5. AC 3: the SITE question survives, separately, and catches whole-site")
|
||||
print(" reversal - which no per-unit check can see")
|
||||
# ⚠️ THE FAULT HERE IS THE ONE THE 2026-08-20 CAPTURE CONTAINS, and it is
|
||||
# INVISIBLE to every per-unit comparison by construction: both inverters are
|
||||
# doing EXACTLY what they were told. What is wrong is the number they were told.
|
||||
# A negative gain is the minimal faithful model of it - an inverted polarity, a
|
||||
# wound-up integrator, a strategy on the wrong side of the meter - and it is not
|
||||
# a reachable configuration (`gain` is float(0.05,1.0)), which is the point: it
|
||||
# stands in for a code regression, which is the case a check can hold the line on.
|
||||
|
||||
|
||||
async def _site_reversed():
|
||||
hass = _SignHass(load_w=2000.0, reversed_units=())
|
||||
c = _sign_site(hass, gain=-0.6)
|
||||
seen = await _drive(c, watch=lambda c: dict(
|
||||
grid=c.grid, site=c.site_sign_wd.tripped,
|
||||
stood=[i.last_write if i.last_write is not None else i.target
|
||||
for i in c.inverters],
|
||||
meas=[i.batt for i in c.inverters]))
|
||||
return c, hass, seen
|
||||
|
||||
|
||||
_c31, _h31, _s31 = asyncio.run(_site_reversed())
|
||||
# ⚠️ THE LAST SAMPLE BEFORE THE TRIP, NOT A FIXED INDEX. After the trip every
|
||||
# command is 0 W by design, so a fixed index reads the REMEDY rather than the
|
||||
# fault and the precondition below would be asserting that a stopped site is
|
||||
# stopped. This is `Run.p2p_between`'s lesson from the rig, in a unit test: name
|
||||
# the window rather than inferring it.
|
||||
_pre31 = [x for x in _s31 if not x["site"]]
|
||||
_mid31 = _pre31[-1]
|
||||
print(f" last cycle before the trip: stood "
|
||||
f"{[round(x) for x in _mid31['stood']]} "
|
||||
f"measured {[round(x) for x in _mid31['meas']]} "
|
||||
f"meter {_mid31['grid']:+.0f} W")
|
||||
check("PRECONDITION: EVERY inverter is obeying - each unit's measured power "
|
||||
"agrees in sign with its own share - and the site is still charging into "
|
||||
"an importing house. Without this the site trip below could be a "
|
||||
"per-unit fault in disguise",
|
||||
all(s * m > 0 for s, m in zip(_mid31["stood"], _mid31["meas"]))
|
||||
and sum(_mid31["stood"]) * _mid31["grid"] < 0)
|
||||
check("⚠️ AC 3. THE SITE WATCHDOG TRIPS AND NOT ONE PER-UNIT WATCHDOG DOES. "
|
||||
"That asymmetry is the card: the fault is in the number the site was "
|
||||
"asking for, which no single inverter owns, and every unit is innocent "
|
||||
"of it",
|
||||
_c31.site_sign_wd.tripped
|
||||
and not any(i.sign_wd.tripped for i in _c31.inverters))
|
||||
print(f" {_c31.site_sign_wd.reason!r}")
|
||||
check("...and it stops the WHOLE site, through the `sign_site` claim by name "
|
||||
"rather than by some other guard happening to stop it",
|
||||
_c31.target == 0.0 and "sign_site" in _c31.reason
|
||||
and all(i.target == 0.0 for i in _c31.inverters))
|
||||
check("...the latch is FLAT - `site_sign_tripped`, beside SAFETY-31's pair - "
|
||||
"and NOT mirrored onto the pre-DEV-02 `sign_tripped`, which is the "
|
||||
"rollback view of a UNIT latch. A downgraded add-on drives exactly one "
|
||||
"actuator; handing it a latch taken on evidence about a roster it cannot "
|
||||
"have would be a trip it can never explain",
|
||||
_c31.store.data.get("site_sign_tripped") is True
|
||||
and "SIGN_DISAGREEMENT" in str(_c31.store.data.get("site_sign_reason"))
|
||||
and _c31.store.data.get("sign_tripped") is not True)
|
||||
check("the status page carries a SITE row of its own, and the banner says the "
|
||||
"site's TOTAL command opposed the meter rather than naming an inverter - "
|
||||
"naming one would send an operator to swap the wrong box",
|
||||
any("SITE SIGN-DISAGREEMENT FAILSAFE" in ck["text"]
|
||||
for ck in _c31.checks())
|
||||
and "total command" in _c31.status_payload()["banner"])
|
||||
_pub30 = {}
|
||||
_c31.mqtt = type("P", (), {"enabled": True,
|
||||
"publish": lambda _s, v: _pub30.update(v),
|
||||
"close": lambda _s: None})()
|
||||
_c31.publish()
|
||||
check("...and the controller-status sensor reports the failsafe state, so a "
|
||||
"site parked at 0 W cannot publish 'running'",
|
||||
_pub30.get("status") == "failsafe")
|
||||
|
||||
# The latch, and the one way out of it.
|
||||
_was31 = _c31.site_sign_wd.tripped
|
||||
asyncio.run(_c31.handle_action("auto_toggle")) # stop
|
||||
check("pressing STOP clears nothing - the condition always goes away on its "
|
||||
"own, because the trip commands 0 W and a site at zero cannot oppose "
|
||||
"anything", _c31.site_sign_wd.tripped and _was31)
|
||||
asyncio.run(_c31.handle_action("auto_toggle")) # the deliberate start
|
||||
check("pressing START clears the latch in memory and on disk together, which "
|
||||
"is the same deliberate human act that clears every other latch here",
|
||||
not _c31.site_sign_wd.tripped
|
||||
and _c31.store.data.get("site_sign_tripped") is False
|
||||
and _c31.store.data.get("site_sign_reason") == "")
|
||||
|
||||
|
||||
async def _site_restart(store):
|
||||
hass = _SignHass(load_w=2000.0)
|
||||
c = _sign_site(hass, store=store, gain=-0.6)
|
||||
await _drive(c, n=3, dt=0.05)
|
||||
return c
|
||||
|
||||
|
||||
_store31 = _MemStore()
|
||||
_store31.data["site_sign_tripped"] = True
|
||||
_store31.data["site_sign_reason"] = "SIGN_DISAGREEMENT: (from before the restart)"
|
||||
_c31r = asyncio.run(_site_restart(_store31))
|
||||
check("⚠️ AND IT SURVIVES A RESTART, which is the only thing that makes it a "
|
||||
"latch rather than a pause. 'Restart the add-on' is the first thing an "
|
||||
"operator staring at a FAILSAFE banner tries, and a site that came back "
|
||||
"armed would drive straight into the fault it had just stopped for",
|
||||
_c31r.site_sign_wd.tripped and _c31r.target == 0.0
|
||||
and "sign_site" in _c31r.reason)
|
||||
|
||||
print()
|
||||
print("6. AC 4: two inverters commanded OPPOSITE SIGNS by a legitimate")
|
||||
print(" allocation, and nothing trips")
|
||||
# ⚠️ THIS IS THE FALSE TRIP THE CARD OPENS WITH, AND IT IS DRIVEN THROUGH THE
|
||||
# SHIPPED PREDICATE RATHER THAN DESCRIBED. Inverter A charging 1500 W while
|
||||
# inverter B discharges 1500 W into a 1500 W import is an ordinary two-inverter
|
||||
# arrangement - a per-unit maintenance charge on A while the loop drives B, or
|
||||
# SAFETY-25's floor pinning one unit. Nothing is faulty. Before this card the
|
||||
# meter convicted A on it.
|
||||
_A_CMD, _B_CMD, _METER = -1500.0, 1500.0, 1500.0
|
||||
_wd_a = SignWatchdog(_ucfg, against=AGAINST_OWN_POWER)
|
||||
_wd_b = SignWatchdog(_ucfg, against=AGAINST_OWN_POWER)
|
||||
_sitecfg = SignWatchdogConfig(
|
||||
min_w=float(SIGN_OPTION_DEFAULTS["site_sign_disagree_w"]),
|
||||
hold_s=float(SIGN_OPTION_DEFAULTS["site_sign_disagree_s"]))
|
||||
_wd_s = SignWatchdog(_sitecfg)
|
||||
for _t in range(0, 1200, 5):
|
||||
_wd_a.evaluate(_A_CMD, _A_CMD, True, T0 + timedelta(seconds=_t))
|
||||
_wd_b.evaluate(_B_CMD, _B_CMD, True, T0 + timedelta(seconds=_t))
|
||||
_wd_s.evaluate(_A_CMD + _B_CMD, _METER, True, T0 + timedelta(seconds=_t))
|
||||
print(f" A commanded {_A_CMD:+.0f} W and measured {_A_CMD:+.0f} W; "
|
||||
f"B {_B_CMD:+.0f} / {_B_CMD:+.0f}; meter {_METER:+.0f} W")
|
||||
check("PRECONDITION: THE COMPARISON THAT SHIPPED CONVICTS INVERTER A HERE, on "
|
||||
"every one of these samples. A is commanded to CHARGE while the meter "
|
||||
"reads IMPORT - opposed, both far over 300 W, and it would have held for "
|
||||
"20 minutes. That is the false trip, and it is asserted rather than "
|
||||
"asserted about",
|
||||
disagrees(_A_CMD, _METER, True, _scfg) is True)
|
||||
check("⚠️ AC 4. NEITHER UNIT TRIPS UNDER THE NEW COMPARISON, over 20 minutes at "
|
||||
"an 85 s hold. Each one is doing exactly what it was told, and its own "
|
||||
"power sensor is the instrument that can say so",
|
||||
not _wd_a.tripped and not _wd_b.tripped)
|
||||
check("...and the SITE watchdog does not trip either, because the shares SUM "
|
||||
"to zero and a 0 W total is not a wrong-direction command - the "
|
||||
"magnitude gate that has always been there, now applied to the quantity "
|
||||
"it belongs on", not _wd_s.tripped and _wd_s.disagree_since is None)
|
||||
# ⚠️ AND THE COUNTERFACTUAL, BECAUSE "nothing tripped" IS ALSO WHAT A DISARMED
|
||||
# GUARD REPORTS. Same site, same meter, but the shares no longer cancel: a NET
|
||||
# -1600 W of charge into a +1500 W import is the site genuinely driving the
|
||||
# wrong way, and it must trip. Without this line the check above passes
|
||||
# identically against a site watchdog that was never wired to anything.
|
||||
_wd_s_net = SignWatchdog(_sitecfg)
|
||||
for _t in range(0, 600, 5):
|
||||
_wd_s_net.evaluate(-1600.0, _METER, True, T0 + timedelta(seconds=_t))
|
||||
check("...and the site question is not thereby disarmed: the same site, "
|
||||
"commanded a NET -1600 W into the same import, DOES trip",
|
||||
_wd_s_net.tripped)
|
||||
|
||||
print()
|
||||
print("7. AC 8: at ONE inverter this card changes NOTHING, and 'nothing' is")
|
||||
print(" asserted rather than assumed")
|
||||
|
||||
|
||||
async def _n1_sign():
|
||||
hass = _SignHass(load_w=2000.0)
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": -0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 1,
|
||||
"auto_start": True}
|
||||
c = Controller(opts, hass, _MemStore(), _P(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -5000.0, 5000.0
|
||||
hass.ctrl = c
|
||||
# ⚠️ A CALL COUNTER, NOT AN OBSERVATION OF THE DETECTOR'S STATE, AND A
|
||||
# MUTATION IS WHY. The first version of the check below read
|
||||
# `site_sign_wd.disagree_since is None` - and arming the site detector at
|
||||
# N=1 as well left this suite GREEN, because the unit detector trips first
|
||||
# at its 1 s hold, parks the inverter, and the site's standing command is
|
||||
# then 0 W: the site predicate is false, so its window is never opened and
|
||||
# "never evaluated" reads identically to "evaluated and found nothing". That
|
||||
# is MUTATION.md's third failure mode - the assertion ran, the sentence was
|
||||
# true, and the data could not reach the failure it names. A counter can
|
||||
# only be zero for the one reason.
|
||||
_n1_calls = []
|
||||
_orig_eval = c.site_sign_wd.evaluate
|
||||
|
||||
def _spy(*a, **kw):
|
||||
_n1_calls.append(a)
|
||||
return _orig_eval(*a, **kw)
|
||||
|
||||
c.site_sign_wd.evaluate = _spy
|
||||
await _drive(c, n=12, dt=0.2)
|
||||
return c, _n1_calls
|
||||
|
||||
|
||||
_c1s, _n1_site_calls = asyncio.run(_n1_sign())
|
||||
_inv1 = _c1s.inverters[0]
|
||||
print(f" roster={_c1s.units} armed against {_inv1.sign_wd.against!r} "
|
||||
f"at {_inv1.sign_wd.cfg.min_w:.0f} W / {_inv1.sign_wd.cfg.hold_s:.0f} s")
|
||||
check("the single unit is graded against THE METER, at the SHIPPED thresholds "
|
||||
"- §6.2's identity, and the whole compatibility promise of this card. "
|
||||
"The unit's own power is not consulted, and `unit_sign_disagree_*` does "
|
||||
"nothing on a one-inverter install",
|
||||
_inv1.sign_wd.against == AGAINST_METER
|
||||
and (_inv1.sign_wd.cfg.min_w, _inv1.sign_wd.cfg.hold_s) == (300.0, 1.0))
|
||||
check("...it trips, on the same evidence and through the same UNIT `failsafe` "
|
||||
"claim as before, commanding 0 W",
|
||||
_inv1.sign_wd.tripped and _c1s.target == 0.0
|
||||
and "failsafe" in _c1s.reason and "sign_site" not in _c1s.reason)
|
||||
check("...the reason sentence still says 'a meter reading', word for word - it "
|
||||
"is what an operator reads, what the action log carries and what is "
|
||||
"persisted, so it is graded on the literal",
|
||||
"against a meter reading" in _inv1.sign_wd.reason)
|
||||
check("...the latch is under the same namespaced key with the same flat "
|
||||
"rollback mirror, and SAFETY-30's site pair is untouched at its default. "
|
||||
"A one-inverter install's state file is byte-identical to what it was",
|
||||
_c1s.store.data.get(TRIPPED_KEY) is True
|
||||
and _c1s.store.data.get("sign_tripped") is True
|
||||
and _c1s.store.data.get("site_sign_tripped") is False
|
||||
and _c1s.store.data.get("site_sign_reason") == "")
|
||||
print(f" site detector evaluated {len(_n1_site_calls)} times over "
|
||||
f"12 cycles")
|
||||
check("⚠️ ...AND THE SITE DETECTOR IS NEVER ARMED. Not 'did not trip', and not "
|
||||
"'its window stayed closed' - NEVER CALLED, counted on the object over "
|
||||
"twelve cycles. That is what says the second detector is ABSENT at a "
|
||||
"roster of one rather than merely quiet, and arming it would be two "
|
||||
"latches and two banners for one fault with a false-positive record "
|
||||
"measured on ONE comparison spent twice",
|
||||
_n1_site_calls == []
|
||||
and not _c1s.site_sign_wd.tripped
|
||||
and _c1s.site_sign_wd.disagree_since is None)
|
||||
check("...the banner is the sentence that shipped",
|
||||
_c1s.status_payload()["banner"]
|
||||
== "FAILSAFE — the command opposed the meter. Inverter held at 0 W.")
|
||||
check("...the status page carries ONE sign row, with no unit tag and no site "
|
||||
"row - an extra row for an identically-duplicated question is a page "
|
||||
"advertising two guards where the install has one",
|
||||
len([ck for ck in _c1s.checks()
|
||||
if "sign watchdog" in ck["text"] or "SIGN-DISAGREEMENT" in ck["text"]
|
||||
]) == 1
|
||||
and not any("site sign" in ck["text"].lower() for ck in _c1s.checks()))
|
||||
check("...and no `sign_site` claim can be filed at a roster of one, so the "
|
||||
"arbitration is byte-identical to what shipped",
|
||||
"sign_site" not in _c1s.reason)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
|
||||
@@ -145,13 +145,35 @@ show("the same blob MERGED with these defaults - what App.options actually is",
|
||||
f"max_w={out.get('max_w')!r}" if ok else out)
|
||||
|
||||
print("\n== C. AC2: a two-inverter blob an operator would POST ==")
|
||||
# ⚠️ B's 4600 W IS FROM ITS DATASHEET, NOT A PLACEHOLDER AND NOT A MEASUREMENT.
|
||||
# SPIKE-04a (2026-09-04) identified inverter B from the owner's model number and
|
||||
# serial - a GoodWe GW5048D-ES, serial `55048ESU22AW0992` - and the datasheet's
|
||||
# Max. Charging / Discharging Power is 4600 W. The 3000 W that stood here was a
|
||||
# hypothesis from before the unit was known and was simply wrong; the 5000 VA AC
|
||||
# nameplate is wrong for this purpose too, because nothing will be connected to
|
||||
# B's MPPTs so the battery path is the ceiling. See goodwe/NOTES.md §1.1b.
|
||||
#
|
||||
# ⚠️ AND IT IS STILL NOT MEASURED. The datasheet prints 4600 W under BATTERY
|
||||
# INPUT DATA, so it is probably DC, while `max_w` is graded against 0x0518 - the
|
||||
# inverter's own AC power. If it is DC the AC ceiling is nearer 4600 x 0.94 =
|
||||
# 4324 W. NOTES.md §1.1b records both readings without picking one, and
|
||||
# SAFETY-20's `min(max_w, dev_max)` is what bounds it correctly once dev_max is
|
||||
# read off the unit. So this blob is what an operator would POST TODAY, not a
|
||||
# claim about what inverter B will turn out to do.
|
||||
#
|
||||
# ⚠️ THE TWO RATINGS ARE STILL DIFFERENT (5000 / 4600) AND MUST STAY DIFFERENT.
|
||||
# This file's own §B is the record of what an instrument that cannot distinguish
|
||||
# its two cases is worth. Note that 5000/4600 is a much NARROWER separation than
|
||||
# the 5000/3000 it replaces - fine here, where nothing computes on the numbers,
|
||||
# and NOT fine in the test fixtures, which is why those keep a wide illustrative
|
||||
# pair instead of the real one.
|
||||
TWO = dict(LIVE, setpoint_entity="", inverters=[
|
||||
{"name": "inverter-a", "setpoint_entity": "number.goodwe_a_setpoint_w",
|
||||
"soc_entity": "sensor.goodwe_a_soc", "batt_entity": "sensor.goodwe_a_battery_power",
|
||||
"max_w": 5000},
|
||||
{"name": "inverter-b", "setpoint_entity": "number.goodwe_b_setpoint_w",
|
||||
"soc_entity": "sensor.goodwe_b_soc", "batt_entity": "sensor.goodwe_b_battery_power",
|
||||
"max_w": 3000}])
|
||||
"max_w": 4600}])
|
||||
ok, out = validate(MERGER.merge(copy.deepcopy(defaults), copy.deepcopy(TWO)))
|
||||
show("two inverters", ok, json.dumps(out.get("inverters")) if ok else out)
|
||||
# The validated blob, for anyone who wants to POST it. Optional: the probe's
|
||||
@@ -162,9 +184,12 @@ except OSError:
|
||||
pass
|
||||
|
||||
print("\n== D. what the schema itself refuses, per entry ==")
|
||||
# The rating here is filler - each entry is refused for a MISSING key, so no
|
||||
# verdict below depends on the number. It carries B's datasheet 4600 W anyway,
|
||||
# so that nothing in this file reads as 3000 W being inverter B's rating.
|
||||
for title, entry in (
|
||||
("no name", {"setpoint_entity": "number.b", "max_w": 3000}),
|
||||
("no setpoint_entity", {"name": "inverter-b", "max_w": 3000}),
|
||||
("no name", {"setpoint_entity": "number.b", "max_w": 4600}),
|
||||
("no setpoint_entity", {"name": "inverter-b", "max_w": 4600}),
|
||||
("no max_w", {"name": "inverter-b", "setpoint_entity": "number.b"}),
|
||||
("max_w over the range", {"name": "inverter-b", "setpoint_entity": "number.b", "max_w": 9999})):
|
||||
ok, out = validate(dict(TWO, inverters=[entry]))
|
||||
|
||||
Reference in New Issue