587 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5.5 568230c422 Release 0.23.0: CHANGELOG review wording fixes
checks / unit (pull_request) Successful in 20m52s
infra-pin / fresh (pull_request) Successful in 2s
- MAINT-28: say the hold is for two inverters (the code gates it on N >= 2).
- EV-03: "no longer buy energy for the car" (the profile is a 7-day median).
- TEL-19: plain wording for the PV sensor point.
- Known issues: add TEL-20 (DOCS names a car sensor id HA does not create).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-16 03:34:13 +01:00
glenn schrooyenandClaude e3cce25cb0 Release 0.23.0: one Known issues heading
checks / unit (pull_request) Successful in 22m6s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-16 02:36:58 +01:00
glenn schrooyenandClaude 8af35172a3 Release 0.23.0
Bump version to 0.23.0 and fold "Not in a release yet" into a new
0.23.0 CHANGELOG section (MAINT-28, CI-17, EV-03, CI-18). Four new
options (ev_*), all with defaults; no option change needed.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-16 02:35:46 +01:00
glenn schrooyenandClaude Opus 5.5 22ef89bf10 CI-18 review: --head needs B checked out; guard the CI image against CI_ONLY
checks / unit (pull_request) Successful in 20m22s
infra-pin / fresh (pull_request) Successful in 1s
The selector reads the graph, and run-affected.sh runs the tests, from the
working tree, so a --base/--head range is only right with the head checked
out. The CI image is built from the merged tree, so an ENV CI_ONLY in its
Dockerfile would make the gate partial; test_affected_tests.py now fails on it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-15 23:29:34 +01:00
glenn schrooyenandClaude b2d3066966 CI-18: selector carries a change through a test that imports another test
checks / unit (pull_request) Successful in 21m20s
infra-pin / fresh (pull_request) Successful in 1s
A test first reached as text (a pattern reader) was never expanded again when a
later path reached it by import, so a test importing it was missed. Expanded and
reached are now tracked apart; the empty diff selects the safety set. Test added.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-15 21:17:26 +01:00
glenn schrooyenandClaude a727dd7ee2 CI-18: affected-test selector for dev rounds; split the longest test files; 10 workers
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Successful in 20m45s
- .gitea/ci/affected_tests.py: which test_*.py a diff reaches (static import
  graph plus names in strings, transitive), a fixed safety set, SELECT ALL for
  anything it cannot map. .gitea/ci/run-affected.sh runs the selection in the
  CI image. run-tests.sh takes CI_ONLY for that; checks.yml never sets it and
  test_affected_tests.py fails if it does. The merge gate still runs every file.
- test_modes_p4 -> p4/p4b/p4c/p4d, test_safety126 -> +b, test_safety125 -> +b:
  same check lines, none dropped (146, 35, 45 before and after).
- run-tests.sh: 10 workers instead of 6, new longest-first order.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-15 20:54:00 +01:00
glenn schrooyenandClaude Opus 5.5 d7b4298092 EV-03 review: one power-unit table for the probe and the reading
checks / unit (pull_request) Successful in 27m3s
infra-pin / fresh (pull_request) Successful in 1s
POWER_UNITS is now derived from _W_PER, so the start-up probe and the
reading cannot drift apart. No behaviour change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-15 16:05:19 +01:00
ev03-devandClaude af7e96e5e5 EV-03 round 4: a power entity that cannot be believed is unreachable
checks / unit (pull_request) Successful in 27m11s
infra-pin / fresh (pull_request) Successful in 2s
- every HA power unit is accepted and converted (mW, W, kW, MW), in the probe
  and in the reading
- a power entity that answers in another unit, with no unit, or not as a
  number makes the reading unavailable: after 30 s it is "Charger not
  reachable" (amber row, WARNING, notification after 5 min), with a Why that
  names the cause (EN and NL)

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 15:06:24 +01:00
ev03-devandClaude 918d44ab33 EV-03 round 3: the power entity is required and reads in W or kW
checks / unit (pull_request) Successful in 27m42s
infra-pin / fresh (pull_request) Successful in 1s
A charger with no usable power entity is refused as "not set up", like a
missing setpoint, read-back or state entity, so House and the house profile
behave as with no charger. An entity that is merely unavailable at probe time
is still the unreachable path. NL: help text "met rust", chip "Laadpaalstoring".

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 13:35:09 +01:00
ev03-devandClaude 678ea13895 EV-03 round 2: a missing car power is unknown, and mode3 E/F has a state
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
- CarTracker.car_w returns None when the current reading carries no power
  (power entity unavailable or in a non-power unit); it can no longer raise
  into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 12:02:17 +01:00
ev03-devandClaude 984f4335a0 EV-03: the charger reader keeps its own power-unit rule
checks / unit (pull_request) Successful in 27m39s
infra-pin / fresh (pull_request) Successful in 1s
test_pv.py part 6 says only the PV reader's named modules may mention its
material, so chargers.py no longer imports pv.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 10:19:14 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00
glenn schrooyenandClaude 63043ea219 CI-17 round 2: stale/dead fixtures take rejected_since from the pinned instant; comment made true
checks / unit (pull_request) Successful in 36m34s
infra-pin / fresh (pull_request) Successful in 1s
The two fixtures ran their cycles at _SRC_NOW but set rejected_since from the
real clock, so the cycle saw inverter-b live while live_units() saw it stale.
Both now use _SRC_NOW, and a check asserts both clocks agree. run_cycle's
comment no longer claims ctl_cycle.py:49 is the only clock read.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 23:39:49 +01:00
glenn schrooyenandClaude 39ca1df232 CI-17: test_peakguard's real-cycle fixture reads the clock once, so host load cannot add peak@site
checks / unit (pull_request) Successful in 37m11s
infra-pin / fresh (pull_request) Successful in 2s
c_src's telegrams were laid up to one datetime.now(); each cycle() then read
the real clock again (ctl_cycle.py:49). Under --cpus 0.25 a cycle takes ~1.3 s,
so by the 23rd sweep cycle the last telegram was older than max_hold_s (30 s),
the guard counted the gap and filed peak@site. The cycles now run AT the
fixture's own instant. Test only; the exact-set checks are unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 22:11:09 +01:00
glenn schrooyenandClaude 79dfcde2bb MAINT-28: test_maint28b live try reads B's lowest SoC through min() (test_named_absence)
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 27m44s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 17:19:15 +01:00
glenn schrooyenandClaude de06a2c6f5 MAINT-28 fix round 5: while the pause holds, the batteries give only what the guard needs
checks / unit (pull_request) Failing after 38m55s
infra-pin / fresh (pull_request) Successful in 1s
H-1: one site limit while the pause holds (the period's largest floor, never under this cycle's), so the other pack no longer gives for the house. New live-try test (A 11 %, B 25 %, 90 min at 6.5 kW) red on 07d23d2. M-1: a 45-min rig-shape test that goes red when the settled check is forced True. M-2/L-2: DECISIONS. CHANGELOG line. test_safety84 n2_charge_banked re-pinned (quarters 3349 and 3950 W, aim 3950 W).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:40:54 +01:00
glenn schrooyenandClaude 9a76f1a968 MAINT-28 fix-forward rounds 1-4, re-applied after the release/1.0 merge
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude 0020756aab Revert "Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)""
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude Opus 5.5 e79d403560 Release 0.22.0: CHANGELOG wording (SAFETY-136 row, SAFETY-111, MAINT-28, MAINT-26)
checks / unit (pull_request) Successful in 26m33s
infra-pin / fresh (pull_request) Successful in 2s
- SAFETY-136 row: the gain is at 10 s late; at 15 s a rig test sent more.
- SAFETY-111: the cycle needs more than 4 nights; the 36 h limit ends it.
- MAINT-28: rig counts were 393-468 flips per 45 min, not one figure.
- MAINT-26 / MAINT-25: the next try is the first start hour after the wait.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-14 12:54:18 +01:00
glenn schrooyenandClaude 634001cb26 Release 0.22.0: CHANGELOG fixes (duplicate Known issues heading, missing full stop)
checks / unit (pull_request) Successful in 27m4s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-14 11:52:41 +01:00
glenn schrooyenandClaude 94214d609e Release 0.22.0: version and CHANGELOG
checks / unit (pull_request) Successful in 36m47s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-14 10:44:36 +01:00
glenn schrooyenandClaude 7bc8ad264b Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)"
checks / unit (pull_request) Successful in 27m32s
infra-pin / fresh (pull_request) Successful in 2s
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 01:33:24 +01:00
glenn schrooyenandClaude e7706150e8 MAINT-28: DECISIONS gives the measured reason for the uncapped give (review M-1); ctl_cycle comment one line + pointer (L-1)
checks / unit (pull_request) Successful in 27m38s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 05:53:55 +01:00
glenn schrooyenandClaude 7edf8484d1 MAINT-28: test_maint28 reads the replay clock directly (main_files.live parsed every app file per cycle): 269 s -> 28 s, same numbers
checks / unit (pull_request) Successful in 42m47s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 03:57:31 +01:00
glenn schrooyenandClaude 29a8a05f30 MAINT-28: shorter test_maint28 runs (892 s -> ~280 s), digests re-pinned on 1b5f7c9; hold kept through the two short holds (documented); DECISIONS duplicate removed
checks / unit (pull_request) Successful in 40m7s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 02:29:27 +01:00
glenn schrooyenandClaude f5bd2a3520 MAINT-28: re-pin test_safety84 n2_charge_banked (the charge no longer restarts in the 5000 W load)
checks / unit (pull_request) Successful in 43m17s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 00:59:41 +01:00
glenn schrooyenandClaude bc5be4964e MAINT-28: N=1 digest test with a banked peak (so the N=1 gate is tested)
checks / unit (pull_request) Successful in 34m0s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 00:20:21 +01:00
glenn schrooyenandClaude edf30f345a MAINT-28: keep the single shaping_suspended(.., maint_aim) call site (test_peak_margin pin); shaping_held takes its answer
checks / unit (pull_request) Successful in 32m46s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:58:19 +01:00
glenn schrooyenandClaude 23359a047d MAINT-28: test_maint28 points at MUTATION.md (test_bytecode)
checks / unit (pull_request) Failing after 34m49s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:29:13 +01:00
glenn schrooyenandClaude 8640bfcbc1 MAINT-28: hold only where MAINT-24 moved the aim (banked peak above the cap); test_safety119 pins stay
checks / unit (pull_request) Failing after 34m27s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:13:57 +01:00
glenn schrooyenandClaude 92f0387415 MAINT-28: reset the hold every cycle, test it; digests vs 1b5f7c9; DECISIONS numbers and mutants
checks / unit (pull_request) Failing after 36m49s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:44:32 +01:00
glenn schrooyenandClaude 4f9aa5223f MAINT-28: the hold is for N=2 and up (SAFETY-87 N=1 pins), N=1 peak digest test
checks / unit (pull_request) Failing after 36m51s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:28:01 +01:00
glenn schrooyenandClaude 8cd10ee6aa MAINT-28: during a real peak the maintenance charge stays paused until the house is clear of the aim
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m11s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 21:51:56 +01:00
glenn schrooyenandClaude 33cfc733d3 MAINT-25: clean test_maint25.py, split its DECISIONS note
checks / unit (pull_request) Successful in 26m39s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 11:08:30 +01:00
glenn schrooyenandClaude de0790e62d MAINT-25: the Home plan shows no cycle during the 7-day back-off
checks / unit (pull_request) Successful in 27m21s
infra-pin / fresh (pull_request) Successful in 1s
homeview.maintenance_runs() ignored backoff_until(); it drew a cycle every
night of the wait. Now no run and a plain line (EN, NL). test_maint25.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 09:57:56 +01:00
glenn schrooyenandClaude b80cfa969f MAINT-24: test_peak_margin pins the maintenance checks to the guard's aim
checks / unit (pull_request) Successful in 29m32s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 08:22:13 +01:00
glenn schrooyenandClaude 6004bfad9a MAINT-24: read the last row without a bare index (test_named_absence)
checks / unit (pull_request) Successful in 26m37s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 08:15:01 +01:00
glenn schrooyenandClaude b44a648cab MAINT-24: test_maint24.py points at MUTATION.md
checks / unit (pull_request) Successful in 28m32s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:51:28 +01:00
glenn schrooyenandClaude 0f5e513f1d MAINT-24: keep the refusal probe beside a maintenance charge
checks / unit (pull_request) Failing after 45m44s
infra-pin / fresh (pull_request) Successful in 2s
The mode trade still lets a SAFETY-73 probe (PROBE_W alone) go on while a pack
is in its maintenance CHARGE phase; test_opt20.py g7 pins it. ch_ch_maint
digest moved (B no longer grid-charges beside A's charge).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:33:04 +01:00
glenn schrooyenandClaude 54a738dd87 MAINT-24: a started maintenance charge gets the cheap night
checks / unit (pull_request) Failing after 41m45s
infra-pin / fresh (pull_request) Successful in 2s
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:07:44 +01:00
glenn schrooyenandClaude Opus 5.5 4066624cce SAFETY-135 round 2: the first guard stop in a period may restart once; tests and docs
checks / unit (pull_request) Successful in 29m42s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-11 19:49:18 +01:00
glenn schrooyenandClaude 66d8777b39 SAFETY-135: a young 15-minute period does not cost the night charge the whole period
checks / unit (pull_request) Successful in 41m54s
infra-pin / fresh (pull_request) Successful in 2s
With battery modes on, a grid charge the peak guard (or a measured headroom)
stops in the first 60 s of a period no longer latches off for the period: it
may start again once the period is 60 s old, if the guard is clear and the
headroom is over START_W. A stop after 60 s latches as before. In a young
period no charge starts while the batteries' give is still falling (over
START_W within 15 s), since the meter may not show that drop yet. The guard
itself is unchanged, so a real over-aim load is cut on the same cycle.

DECISIONS/SAFETY-135-young-period.md, test_safety135.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-10 17:43:28 +01:00
goodwe-agent 0f9c119bcf SAFETY-136 round 2: tests for override and direction, true wording
checks / unit (pull_request) Successful in 26m2s
infra-pin / fresh (pull_request) Successful in 2s
F1 the on-change case is tested as slow, F2 override and direction checks,
F3 the 3.75 s rule in the texts, F4 the quarter figures and the live note.
No behaviour change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 20:51:06 +01:00
goodwe-agent c50e2279dd SAFETY-136: a gentler loop on a slow meter until the last move shows
checks / unit (pull_request) Successful in 26m18s
infra-pin / fresh (pull_request) Successful in 2s
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 14:49:26 +01:00
glenn schrooyenandClaude Opus 5.5 8f0b8477e6 MAINT-21 review: two source scans read the split files too
checks / unit (pull_request) Successful in 31m44s
infra-pin / fresh (pull_request) Successful in 1s
test_safety118's "size rule is gone" and test_validate's "no numeric
maintenance_* fallback" read app/main.py only; the code they guard can now
sit in app/ctl_*.py, where a regression passed unseen. Both read
main_files.source() for main.py now. Tests only; no app change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-09 07:15:14 +01:00
glenn schrooyenandClaude 58b6fa35f5 MAINT-21 round 2: keep the move pure - revert the added DECISIONS text, restore cut comments
checks / unit (pull_request) Successful in 26m32s
infra-pin / fresh (pull_request) Successful in 1s
Router T241: the comments commit had put new rationale into
MAIN-orchestration.md and cut comment lines that the note at 56fc41f did not
hold.

- DECISIONS/MAIN-orchestration.md is the 56fc41f text plus the one sentence
  that the Controller is split into app/main.py and app/ctl_*.py.
- Comments whose content is not in a DECISIONS note at 56fc41f are back in the
  code verbatim: MAINT-05 one config, the SAFETY-02, SAFETY-42/34,
  SAFETY-30 site half, SAFETY-31 and SAFETY-18 latch blocks in __init__, the
  _grade_store_migration docstring and comment, the trade_power_w docstring,
  the rows.py docstrings.
- Kept: cuts of text already in the note, the SMA-10 / SAFETY-137 / SMA-2
  pointers, the SAFETY-32 line fix.

No code change: maint21_same_ast OK, maint20_same_code -OO same.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 05:48:00 +01:00
glenn schrooyenandClaude 902da3f723 MAINT-21: comments only - trim restated notes, add DECISIONS pointers
checks / unit (pull_request) Successful in 25m17s
infra-pin / fresh (pull_request) Successful in 1s
No code change: tools/maint21_same_ast.py and tools/maint20_same_code.py HEAD~
both print OK, and the -OO code objects are the same.

- Trims 56 comment and docstring lines (2088 -> 2032) in app/main.py and the
  new files that only restated their MAIN-orchestration.md bullet, each cut to
  its first sentence and a pointer. What the cut comments said and the bullet
  did not is now in the bullet: why a SAFETY-02 latch is restored, why the
  SAFETY-30 site check is not armed at one inverter, the SAFETY-18 re-derive,
  the MAINT-05 one-config rule, the OPT-09 sizing rules, the "no plan" row,
  the 5 400 s age bound, and the guard being the only latch repair.
- Adds the missing DECISIONS pointers on the SMA-10, SAFETY-137 and SMA-2
  comments (FALLBACK_BUDGET_S, write_setpoint, _await_inflight,
  _release_last, the retry wait, the failed-release branch, release_zero_sent,
  the in-flight write, the stop_event hand-back, the SMA-2 read and driver).
- DECISIONS/SAFETY-32: the stale `main.py:932-936` now names
  Controller.pack_floor_soc.
- main.py's docstring and import block say where the Controller's parts are.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:41:34 +01:00
glenn schrooyenandClaude 27a867f34b MAINT-21: app/ctl_tasks.py - Controller methods that run as tasks
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. TasksMixin: run_control, run_tariff_refresh, fresh_tariff_plan and the store-migration grade. tools/maint21_same_ast.py: OK.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:30:04 +01:00
glenn schrooyenandClaude 66952beb53 MAINT-21: app/ctl_status.py - Controller methods that build the status and MQTT output
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. StatusMixin: checks, status_payload, forecast_payload, publish, mqtt_command, handle_action, why_words. tools/maint21_same_ast.py: OK.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:30:00 +01:00
glenn schrooyenandClaude d3504fbbe7 MAINT-21: app/ctl_alarms.py - Controller methods that raise and clear alarms
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. AlarmsMixin: the check_* alarms and the loop-alarm helpers. tools/maint21_same_ast.py: OK.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:29:56 +01:00