The period without the car was clipped at 0 W, so batteries covering the car
were charged to the house and the floor alarm fired (rig F-1). New
car_exclude_alarm keeps the sign of the rest of the period; car_exclude (the
cover-off guard input) is unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.
Co-Authored-By: Claude <noreply@anthropic.com>
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.
Co-Authored-By: Claude <noreply@anthropic.com>
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.
Co-Authored-By: Claude <noreply@anthropic.com>
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.
Co-Authored-By: Claude <noreply@anthropic.com>
POWER_UNITS is now derived from _W_PER, so the start-up probe and the
reading cannot drift apart. No behaviour change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- every HA power unit is accepted and converted (mW, W, kW, MW), in the probe
and in the reading
- a power entity that answers in another unit, with no unit, or not as a
number makes the reading unavailable: after 30 s it is "Charger not
reachable" (amber row, WARNING, notification after 5 min), with a Why that
names the cause (EN and NL)
Co-Authored-By: Claude <noreply@anthropic.com>
A charger with no usable power entity is refused as "not set up", like a
missing setpoint, read-back or state entity, so House and the house profile
behave as with no charger. An entity that is merely unavailable at probe time
is still the unreachable path. NL: help text "met rust", chip "Laadpaalstoring".
Co-Authored-By: Claude <noreply@anthropic.com>
- CarTracker.car_w returns None when the current reading carries no power
(power entity unavailable or in a non-power unit); it can no longer raise
into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().
Co-Authored-By: Claude <noreply@anthropic.com>
test_pv.py part 6 says only the PV reader's named modules may mention its
material, so chargers.py no longer imports pv.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py
Co-Authored-By: Claude <noreply@anthropic.com>
H-1: one site limit while the pause holds (the period's largest floor, never under this cycle's), so the other pack no longer gives for the house. New live-try test (A 11 %, B 25 %, 90 min at 6.5 kW) red on 07d23d2. M-1: a 45-min rig-shape test that goes red when the settled check is forced True. M-2/L-2: DECISIONS. CHANGELOG line. test_safety84 n2_charge_banked re-pinned (quarters 3349 and 3950 W, aim 3950 W).
Co-Authored-By: Claude <noreply@anthropic.com>
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.
Co-Authored-By: Claude <noreply@anthropic.com>
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.
Co-Authored-By: Claude <noreply@anthropic.com>
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.
Co-Authored-By: Claude <noreply@anthropic.com>
homeview.maintenance_runs() ignored backoff_until(); it drew a cycle every
night of the wait. Now no run and a plain line (EN, NL). test_maint25.py.
Co-Authored-By: Claude <noreply@anthropic.com>
The mode trade still lets a SAFETY-73 probe (PROBE_W alone) go on while a pack
is in its maintenance CHARGE phase; test_opt20.py g7 pins it. ch_ch_maint
digest moved (B no longer grid-charges beside A's charge).
Co-Authored-By: Claude <noreply@anthropic.com>
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes on, a grid charge the peak guard (or a measured headroom)
stops in the first 60 s of a period no longer latches off for the period: it
may start again once the period is 60 s old, if the guard is clear and the
headroom is over START_W. A stop after 60 s latches as before. In a young
period no charge starts while the batteries' give is still falling (over
START_W within 15 s), since the meter may not show that drop yet. The guard
itself is unchanged, so a real over-aim load is cut on the same cycle.
DECISIONS/SAFETY-135-young-period.md, test_safety135.py.
Co-Authored-By: Claude <noreply@anthropic.com>
F1 the on-change case is tested as slow, F2 override and direction checks,
F3 the 3.75 s rule in the texts, F4 the quarter figures and the live note.
No behaviour change.
Co-Authored-By: Claude <noreply@anthropic.com>
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.
Co-Authored-By: Claude <noreply@anthropic.com>
Router T241: the comments commit had put new rationale into
MAIN-orchestration.md and cut comment lines that the note at 56fc41f did not
hold.
- DECISIONS/MAIN-orchestration.md is the 56fc41f text plus the one sentence
that the Controller is split into app/main.py and app/ctl_*.py.
- Comments whose content is not in a DECISIONS note at 56fc41f are back in the
code verbatim: MAINT-05 one config, the SAFETY-02, SAFETY-42/34,
SAFETY-30 site half, SAFETY-31 and SAFETY-18 latch blocks in __init__, the
_grade_store_migration docstring and comment, the trade_power_w docstring,
the rows.py docstrings.
- Kept: cuts of text already in the note, the SMA-10 / SAFETY-137 / SMA-2
pointers, the SAFETY-32 line fix.
No code change: maint21_same_ast OK, maint20_same_code -OO same.
Co-Authored-By: Claude <noreply@anthropic.com>
No code change: tools/maint21_same_ast.py and tools/maint20_same_code.py HEAD~
both print OK, and the -OO code objects are the same.
- Trims 56 comment and docstring lines (2088 -> 2032) in app/main.py and the
new files that only restated their MAIN-orchestration.md bullet, each cut to
its first sentence and a pointer. What the cut comments said and the bullet
did not is now in the bullet: why a SAFETY-02 latch is restored, why the
SAFETY-30 site check is not armed at one inverter, the SAFETY-18 re-derive,
the MAINT-05 one-config rule, the OPT-09 sizing rules, the "no plan" row,
the 5 400 s age bound, and the guard being the only latch repair.
- Adds the missing DECISIONS pointers on the SMA-10, SAFETY-137 and SMA-2
comments (FALLBACK_BUDGET_S, write_setpoint, _await_inflight,
_release_last, the retry wait, the failed-release branch, release_zero_sent,
the in-flight write, the stop_event hand-back, the SMA-2 read and driver).
- DECISIONS/SAFETY-32: the stale `main.py:932-936` now names
Controller.pack_floor_soc.
- main.py's docstring and import block say where the Controller's parts are.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. TasksMixin: run_control, run_tariff_refresh, fresh_tariff_plan and the store-migration grade. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. StatusMixin: checks, status_payload, forecast_payload, publish, mqtt_command, handle_action, why_words. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. AlarmsMixin: the check_* alarms and the loop-alarm helpers. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. CycleMixin: cycle() and _shadow_settle(). cycle() is not cut up. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. TradeMixin: trade sizing, the mode runs, the day plan, the peak floors, drain and charge limits, pack actions. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. WritesMixin: write_setpoint, write_refusal, _write_unit, _hand_back, the refusal evidence, heartbeats and the site release/zero commands. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. InputsMixin: read_inputs, _read_unit, live_units and the other readers of the meter, packs, PV and forecast. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves why_raised, why_key, tariff_plan_row and arbitrage_row out of app/main.py unchanged. main.py imports them, so app.main still exports them. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
- check_peak_floor_limited: restore the SAFETY-25 line (the reserve sentence is
in messages.peak_reserve() on every branch, unreadable SoC included).
- Three status-page comments that no longer said anything (SAFETY-20 row,
AC 5 delivery row, banner-vs-text) now say their rule in one line.
- tariff_refresh_wanted docstring: no orphan "TARIFF-24)" line.
- MAIN-orchestration.md: blank line before the first heading.
- MAIN-orchestration-archive.md: refilled intro; says how to find a section
from a main.py pointer.
No code change: maint20_same_code.py 16029d7 -> SAME CODE, -OO same.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>