ems-agentandClaude e348a808ff EV-05 round 8: Off respects the owed-only rule; grade out only a car Solar runs
checks / unit (pull_request) Successful in 26m14s
infra-pin / fresh (pull_request) Successful in 1s
Review of fa11dc3:
- Solar to Off writes no 0 A when Solar never had the charger (shadow or a
  stopped control since the start) or its not-writing 0 A is already taken
  (N10, Expected 11), as the shutdown does since round 7.
- car_solar_can_cut() also needs a car Solar runs: plan.a > 0, its own phase
  change, or its own 0 A inside EV-15's OWN_PAUSE_MAX_S.

Tests: the four p_off shapes (and Manual); p_paused at 1000 s and 890 s and
an own pause older than 85 s, each against an Off twin; the near-end rule
with slow batteries that keep headroom (review p_ne2).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 22:17:21 +01:00
ems-agentandClaude fa11dc3d85 EV-05 round 7: Solar watches while not writing; shadow start writes nothing
checks / unit (pull_request) Successful in 24m28s
infra-pin / fresh (pull_request) Successful in 2s
Review of b4a222f, brief v6 Expected 11 (owner 2026-11-18):
- Solar keeps watching for another writer while it is not writing (Stop,
  shadow, safety stop), so hold is true for every reader: the exit, the
  shutdown, the peak alarms, and Start afterwards.
- car_solar_can_cut() also needs Solar to be writing: the peak alarms stand
  as in Off and the quarter is banked.
- A start or restart in Solar with shadow on writes nothing (the
  not-writing 0 A is owed only when Solar had the charger before).
- Once that exit 0 A is taken, nothing more is written, shutdown included.

Tests: alarm rows for Stop, shadow on and safety stop against an Off twin;
shutdown after another writer in shadow and Stop; a start in shadow with the
car already charging; Start after a stop; two variants inside the 30 s watch.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 20:17:58 +01:00
ems-agentandClaude b4a222f9e8 EV-05 round 6: grade the car out only while Solar can cut it
checks / unit (pull_request) Successful in 25m32s
infra-pin / fresh (pull_request) Successful in 1s
Review of 69f5818:
- Solar grades the car out of the peak alarms only while it can really cut
  it (not under another writer's hold, a refused or given-up write, an
  untaken way-out 0 A, a charger fault, an unreadable charger). Otherwise
  the alarms stand as in Off and the quarter is banked as the car's.
- A battery refusing to give counts for nothing at every N (N=1:
  Controller.batt_refused); the site safety stops leave none able; a
  battery switched Off still counts (the guard draws on it).
- Only pressing Solar lifts Solar's other-writer hold: leaving Solar, or
  setting Manual's values, no longer writes over another writer (N10).

Tests: Solar vs Off twins for another writer, a refused cut write and a
refused fault 0 A; N=1 refusing battery against a car-Off twin; N10 on every
exit and on Manual value changes; the able_w cap; batteries switched Off.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 18:50:37 +01:00
ems-agentandClaude 69f58181bc EV-05 round 5: headroom counts only the batteries that can give
checks / unit (pull_request) Successful in 24m24s
infra-pin / fresh (pull_request) Successful in 2s
Review of 8818768: the headroom test compared the output with the site
rating, which still counted a battery refusing to give (SAFETY-73) or under
a safety stop, so the 15 s wait ran at the real maximum (N4). Now only the
units that can give (above their cut-out, not refusing, not stopped,
switched on) count, in what they give and in their ratings.

Tests: R5a (A refuses, B at full rating, against a car-Off twin: the cut at
910, period 3361 W), R5b (headroom and a slow battery: the cut at exactly
15 s), R5c (floor-limited alone decides: cut at once). DOCS wrapped to 79.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 17:27:17 +01:00
ems-agentandClaude 8818768dab EV-05 round 4: the cut waits only while the batteries have headroom
checks / unit (pull_request) Successful in 23m43s
infra-pin / fresh (pull_request) Successful in 1s
Review of d2504ef, brief v5 Expected 8 (owner 2026-11-18): the 15 s wait
needs batteries that can still raise their output: above the cut-out, the
guard neither saturated nor floor-limited, and their output more than 100 W
under what they can give. Otherwise the car is cut at once.

Tests: R4/N4 rows against a car-Off twin (house to 25900 and 25950 W, aim
3400 W) land under the aim; T21/T22 cut at once beyond the batteries; the
T21b catch rows and T44 (0 cut pauses) stay green.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 16:02:01 +01:00
ems-agentandClaude d2504efa82 EV-05 round 3: a refused way-out 0 A is tried again; one cut per excess
checks / unit (pull_request) Successful in 24m5s
infra-pin / fresh (pull_request) Successful in 2s
Review of 17a7b29:
- Critical: every way out of Solar (Off, Stop, shadow, safety stop, charger
  error, stuck reading, no car) now owes a 0 A until the charger takes it:
  tried again 60 s apart, 3 times (EV-04's rule), then the gave-up row and
  CHARGER_REFUSED; never over another writer. Shutdown does not trust last_a
  while a write of ours is unconfirmed. The card no longer says paused while
  the 0 A is not taken.
- Major: an excess episode is taken off the car once, measured from the car's
  power when it began, until the car shows it and 15 s more.

Tests: refused-then-accepted 0 A for each exit, a 0 A never taken, shutdown
during a start write's read-back, a cut from 16 A with a slow car; the fuzz
checks refused exits of every kind (N9).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 12:15:00 +01:00
ems-agentandClaude 17a7b299d2 EV-05 round 2: the peak cut waits 15 s while a battery can give
checks / unit (pull_request) Successful in 23m32s
infra-pin / fresh (pull_request) Successful in 1s
Owner 2026-11-18 (dev finding 1, brief v4 Expected 8): while a battery is
above its cut-out, the car's peak cut waits until the guard has wanted power
for 15 s in a row (CUT_WAIT_S), so a cloud edge the batteries catch does not
pause the car. It cuts at once with no battery able, or with 120 s or less of
the 15-minute period left (CUT_NEAR_END_S: waiting 15 s then costs at most
8/7 of the cut, taken off the car at once).

Tests: T21/T22 cut at 15 s and not sooner, the period lands under the aim;
T21b a house step and a cloud edge the batteries catch: no cut, no pause;
T24 (c) late in the period: the cut at once, under the aim; T12's cut row
with the batteries at their cut-out. The harness's battery level model was
1000x too fast (round 1); fixed. The 10-hour day: 0 cut pauses in both
priorities.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 10:13:02 +01:00
ems-agentandClaude 8ba3e1c337 EV-05: shutdown keeps one command_site_release() call site
checks / unit (pull_request) Successful in 24m44s
infra-pin / fresh (pull_request) Successful in 1s
CI run 1737: test_sma10_two_idle_states counts the call lines of
command_site_release() in main.py (the Stop button and shutdown, 2); the
Solar-first branch had made it 3. Same order as before: in Solar the
charger's 0 A first, in Manual the inverters first.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 00:29:05 +01:00
ems-agentandClaude 29480fda47 EV-05: car Solar mode (spare sun to the car, Batteries or Car first, cut first for the peak)
checks / unit (pull_request) Failing after 24m58s
infra-pin / fresh (pull_request) Successful in 1s
Solar charges the car from the signed spare sun (car + battery charge - grid
import), less the batteries' room (Batteries first) and the sun kept back,
whole amps rounded down, at most one change per 30 s and only on 1 A. It
starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A.
Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min
down, one switch per 10 min). What the peak guard would ask the batteries for
is taken off the car first, at once. Every way out of Solar ends at 0 A,
written once; at shutdown before the inverters go to 0 W.

- app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write
  site, its sequence and watch); spare_w, car_target_w, amps_for.
- app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for
  Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order.
- Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh,
  three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG.
- test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks
  that pinned "Solar is refused" / "three entities" updated.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 23:54:06 +01:00
admin 9fdce023e9 Merge pull request 'EV-15: the add-on's own phase change at the peak reserve raises no false alarm' (#262) from EV-15 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-17 17:15:51 +01:00
glenn schrooyenandClaude Opus 5.5 7788543e09 EV-15 review: reflow the _car_own_pause docstring (one 123-char line)
checks / unit (pull_request) Successful in 22m10s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-17 16:51:41 +01:00
glenn schrooyenandClaude 6d7046fc45 EV-15 round 2: the grace opens when the 0 A write is sent
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
The writer runs beside the cycle and the car can stop before the write
returns, so no sequence existed yet and the latch set. Window now opens at
send (zero_sent_at), cleared on return; ends on another writer in the tail too.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 15:24:30 +01:00
glenn schrooyenandClaude 07f703d1bc EV-15: test_ev15 guards its own indexing (named absence)
checks / unit (pull_request) Successful in 21m47s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:39:11 +01:00
glenn schrooyenandClaude 2cfbc4aec8 EV-15: the add-on's own phase change at the peak reserve raises no false alarm
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:26:56 +01:00
admin f66048b287 Merge pull request 'Release 0.24.0' (#260) from release-0.24.0 into release/1.0
infra-pin / fresh (push) Successful in 2s
checks / unit (pull_request) Successful in 21m46s
infra-pin / fresh (pull_request) Successful in 1s
2026-11-17 08:38:29 +01:00
review-agentandClaude Opus 5.5 69a1ccce1f REL-0.24.0 review: CHANGELOG wording (false-alarm scope, MQTT for HA controls, OPT-31 car charger)
checks / unit (pull_request) Successful in 22m11s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 08:15:59 +01:00
glenn schrooyenandClaude 9a355144fc Release 0.24.0: version bump and CHANGELOG
checks / unit (pull_request) Successful in 23m22s
infra-pin / fresh (pull_request) Successful in 2s
Minor bump: car Manual mode (EV-04), car-alone peak alarm fixes
(EV-10, EV-11, EV-12, EV-10b). Two new options with defaults
(ev_batt_cover, ev_mode_start); existing installs need no option change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 07:19:58 +01:00
admin 628bde8013 Merge pull request 'EV-10b: grade the alarm on the house alone, no 0 W clip' (#259) from EV-10b into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-17 00:20:55 +01:00
review-agentandClaude Opus 5.5 ff2eebe28b EV-10b review: pin the done-part clip and the car's power now in test_ev10b
checks / unit (pull_request) Successful in 22m9s
infra-pin / fresh (pull_request) Successful in 1s
Two checks a mutant survived: crediting the car-made export in the done part,
and taking off the car's quarter average instead of its power now.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-16 23:58:13 +01:00
glenn schrooyenandClaude b12776c705 EV-10b: grade the alarm on the house alone without the 0 W clip
checks / unit (pull_request) Successful in 22m5s
infra-pin / fresh (pull_request) Successful in 2s
The period without the car was clipped at 0 W, so batteries covering the car
were charged to the house and the floor alarm fired (rig F-1). New
car_exclude_alarm keeps the sign of the rest of the period; car_exclude (the
cover-off guard input) is unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 22:16:29 +01:00
admin b86c0153cf Merge pull request 'EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write is not another writer' (#258) from EV-10 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-16 20:54:30 +01:00
Claude 269b89d6b0 EV-10 round 3: grade the floor case on the same landing with and without the car; per-quarter latches independent of the cover option; stricter write-mute test
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 19:28:02 +01:00
Claude 646f61e730 EV-10 round 2: judge the car against the alarm's own landing; test failed writes; honest hold wording
checks / unit (pull_request) Successful in 22m4s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 18:07:25 +01:00
Claude a60342e4e8 EV-10: test_ev10 points at MUTATION.md and guards its indexed reads
checks / unit (pull_request) Successful in 20m36s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 16:12:42 +01:00
Claude 50d5ae90d2 EV-11: the end of a charging session clears the car-over state at once
checks / unit (pull_request) Failing after 29m5s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:41:57 +01:00
Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
admin 75ebe22a4d Merge pull request 'EV-04: car Manual mode, never throttled for the peak, no false guard alarms' (#257) from EV-04 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-16 09:21:04 +01:00
glenn schrooyenandClaude 6e6344eb02 EV-04 round 3: guard the L4 test's reads for test_named_absence
checks / unit (pull_request) Successful in 21m33s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 08:22:16 +01:00
glenn schrooyenandClaude f31dcb62b6 EV-04 round 3: undo restores the current in shadow mode too, energy rule catches a frozen 6 A figure, settle after a refused select
checks / unit (pull_request) Failing after 21m10s
infra-pin / fresh (pull_request) Successful in 1s
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 07:59:15 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
admin b65609133e Merge pull request 'Release 0.23.0' (#255) from release-0.23.0 into release/1.0
infra-pin / fresh (push) Successful in 1s
checks / unit (pull_request) Successful in 23m0s
infra-pin / fresh (pull_request) Successful in 2s
Release 0.23.0 (#255)
2026-11-16 03:55:37 +01:00
glenn schrooyenandClaude Opus 5.5 568230c422 Release 0.23.0: CHANGELOG review wording fixes
checks / unit (pull_request) Successful in 20m52s
infra-pin / fresh (pull_request) Successful in 2s
- MAINT-28: say the hold is for two inverters (the code gates it on N >= 2).
- EV-03: "no longer buy energy for the car" (the profile is a 7-day median).
- TEL-19: plain wording for the PV sensor point.
- Known issues: add TEL-20 (DOCS names a car sensor id HA does not create).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-16 03:34:13 +01:00
glenn schrooyenandClaude e3cce25cb0 Release 0.23.0: one Known issues heading
checks / unit (pull_request) Successful in 22m6s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-16 02:36:58 +01:00
glenn schrooyenandClaude 8af35172a3 Release 0.23.0
Bump version to 0.23.0 and fold "Not in a release yet" into a new
0.23.0 CHANGELOG section (MAINT-28, CI-17, EV-03, CI-18). Four new
options (ev_*), all with defaults; no option change needed.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-16 02:35:46 +01:00
admin 5fc92cf6e8 Merge pull request 'CI-18: affected-test selector for dev rounds, split the longest test files, 10 workers' (#254) from CI-18 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-16 00:31:50 +01:00
glenn schrooyenandClaude Opus 5.5 22ef89bf10 CI-18 review: --head needs B checked out; guard the CI image against CI_ONLY
checks / unit (pull_request) Successful in 20m22s
infra-pin / fresh (pull_request) Successful in 1s
The selector reads the graph, and run-affected.sh runs the tests, from the
working tree, so a --base/--head range is only right with the head checked
out. The CI image is built from the merged tree, so an ENV CI_ONLY in its
Dockerfile would make the gate partial; test_affected_tests.py now fails on it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-15 23:29:34 +01:00
glenn schrooyenandClaude b2d3066966 CI-18: selector carries a change through a test that imports another test
checks / unit (pull_request) Successful in 21m20s
infra-pin / fresh (pull_request) Successful in 1s
A test first reached as text (a pattern reader) was never expanded again when a
later path reached it by import, so a test importing it was missed. Expanded and
reached are now tracked apart; the empty diff selects the safety set. Test added.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-15 21:17:26 +01:00
glenn schrooyenandClaude 17b65785b7 CI-18: checks.yml comments carry the measured run time and the worker count
checks / unit (pull_request) Successful in 20m41s
infra-pin / fresh (pull_request) Successful in 1s
Comment-only: "~15 to run" was stale (runs took 27 min at 6 workers); the CI-18
run at 10 workers took 20 min 56 s (run 1682).

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-15 21:16:05 +01:00
glenn schrooyenandClaude a727dd7ee2 CI-18: affected-test selector for dev rounds; split the longest test files; 10 workers
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Successful in 20m45s
- .gitea/ci/affected_tests.py: which test_*.py a diff reaches (static import
  graph plus names in strings, transitive), a fixed safety set, SELECT ALL for
  anything it cannot map. .gitea/ci/run-affected.sh runs the selection in the
  CI image. run-tests.sh takes CI_ONLY for that; checks.yml never sets it and
  test_affected_tests.py fails if it does. The merge gate still runs every file.
- test_modes_p4 -> p4/p4b/p4c/p4d, test_safety126 -> +b, test_safety125 -> +b:
  same check lines, none dropped (146, 35, 45 before and after).
- run-tests.sh: 10 workers instead of 6, new longest-first order.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-15 20:54:00 +01:00
admin 7513fd9439 Merge pull request 'EV-03: car charger seam, Alfen HA driver, read-only Car card' (#253) from EV-03 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-15 16:32:50 +01:00
glenn schrooyenandClaude Opus 5.5 d7b4298092 EV-03 review: one power-unit table for the probe and the reading
checks / unit (pull_request) Successful in 27m3s
infra-pin / fresh (pull_request) Successful in 1s
POWER_UNITS is now derived from _W_PER, so the start-up probe and the
reading cannot drift apart. No behaviour change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-15 16:05:19 +01:00
ev03-devandClaude af7e96e5e5 EV-03 round 4: a power entity that cannot be believed is unreachable
checks / unit (pull_request) Successful in 27m11s
infra-pin / fresh (pull_request) Successful in 2s
- every HA power unit is accepted and converted (mW, W, kW, MW), in the probe
  and in the reading
- a power entity that answers in another unit, with no unit, or not as a
  number makes the reading unavailable: after 30 s it is "Charger not
  reachable" (amber row, WARNING, notification after 5 min), with a Why that
  names the cause (EN and NL)

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 15:06:24 +01:00
ev03-devandClaude 918d44ab33 EV-03 round 3: the power entity is required and reads in W or kW
checks / unit (pull_request) Successful in 27m42s
infra-pin / fresh (pull_request) Successful in 1s
A charger with no usable power entity is refused as "not set up", like a
missing setpoint, read-back or state entity, so House and the house profile
behave as with no charger. An entity that is merely unavailable at probe time
is still the unreachable path. NL: help text "met rust", chip "Laadpaalstoring".

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 13:35:09 +01:00
ev03-devandClaude 678ea13895 EV-03 round 2: a missing car power is unknown, and mode3 E/F has a state
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
- CarTracker.car_w returns None when the current reading carries no power
  (power entity unavailable or in a non-power unit); it can no longer raise
  into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 12:02:17 +01:00
ev03-devandClaude 984f4335a0 EV-03: the charger reader keeps its own power-unit rule
checks / unit (pull_request) Successful in 27m39s
infra-pin / fresh (pull_request) Successful in 1s
test_pv.py part 6 says only the PV reader's named modules may mention its
material, so chargers.py no longer imports pv.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 10:19:14 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00
admin 6bf37597f8 Merge pull request 'CI-17: test_peakguard's real-cycle fixture runs at its own instant (host-load independent)' (#252) from CI-17 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-15 00:50:50 +01:00
glenn schrooyenandClaude 63043ea219 CI-17 round 2: stale/dead fixtures take rejected_since from the pinned instant; comment made true
checks / unit (pull_request) Successful in 36m34s
infra-pin / fresh (pull_request) Successful in 1s
The two fixtures ran their cycles at _SRC_NOW but set rejected_since from the
real clock, so the cycle saw inverter-b live while live_units() saw it stale.
Both now use _SRC_NOW, and a check asserts both clocks agree. run_cycle's
comment no longer claims ctl_cycle.py:49 is the only clock read.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 23:39:49 +01:00
glenn schrooyenandClaude 39ca1df232 CI-17: test_peakguard's real-cycle fixture reads the clock once, so host load cannot add peak@site
checks / unit (pull_request) Successful in 37m11s
infra-pin / fresh (pull_request) Successful in 2s
c_src's telegrams were laid up to one datetime.now(); each cycle() then read
the real clock again (ctl_cycle.py:49). Under --cpus 0.25 a cycle takes ~1.3 s,
so by the 23rd sweep cycle the last telegram was older than max_hold_s (30 s),
the guard counted the gap and filed peak@site. The cycles now run AT the
fixture's own instant. Test only; the exact-set checks are unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 22:11:09 +01:00