EV-05 round 5: headroom counts only the batteries that can give
Review of 8818768: the headroom test compared the output with the site
rating, which still counted a battery refusing to give (SAFETY-73) or under
a safety stop, so the 15 s wait ran at the real maximum (N4). Now only the
units that can give (above their cut-out, not refusing, not stopped,
switched on) count, in what they give and in their ratings.
Tests: R5a (A refuses, B at full rating, against a car-Off twin: the cut at
910, period 3361 W), R5b (headroom and a slow battery: the cut at exactly
15 s), R5c (floor-limited alone decides: cut at once). DOCS wrapped to 79.
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
@@ -85,6 +85,16 @@ inputs (`car_sun_inputs`) and runs the writer in the same background task.
|
||||
were already at full output, and the period landed over the aim (review
|
||||
repro: house 25 900 and 25 950 W, test_ev05.py R4/N4 against a car-Off twin).
|
||||
|
||||
## Round 5 (review of 8818768)
|
||||
|
||||
- **Headroom counts only the batteries that can give** (`ctl_car._car_giving`):
|
||||
above their cut-out, not refusing to give (SAFETY-73), not under a safety
|
||||
stop, switched on. Their output is compared with their own ratings (and
|
||||
`guard.able_w` when the guard names it). Before, the site rating still
|
||||
counted a refusing unit, so a battery that gave its full rating looked like
|
||||
it had headroom and the cut waited (review repro: battery A refuses, house to
|
||||
20 950 W, period 3436 W against the twin's 3363 W).
|
||||
|
||||
## Solar kWh
|
||||
|
||||
Per cycle in Solar: `min(car power, max(0, spare - room))` Batteries first,
|
||||
|
||||
+30
-30
@@ -3327,14 +3327,14 @@ checks within 10 seconds that the charger took it.
|
||||
current again only if the charger shows a different one.
|
||||
- Off writes nothing, ever.
|
||||
|
||||
**Solar mode.** Choose *Solar* on Home (or `Solar` on `select.goodwe_car_mode`)
|
||||
and where spare sun goes first: **Batteries** or **Car** (`select.goodwe_car_sun_first`).
|
||||
Both apply at once, with no restart.
|
||||
**Solar mode.** Choose *Solar* on Home (or `Solar` on
|
||||
`select.goodwe_car_mode`) and where spare sun goes first: **Batteries** or
|
||||
**Car** (`select.goodwe_car_sun_first`). Both apply at once, with no restart.
|
||||
|
||||
- *Spare sun* is solar production less the house, measured without a solar
|
||||
sensor: the car's power, plus what the batteries charge, less what the grid
|
||||
gives. A grid charge of the batteries, or batteries giving more than the house
|
||||
uses, is never spare sun.
|
||||
gives. A grid charge of the batteries, or batteries giving more than the
|
||||
house uses, is never spare sun.
|
||||
- *Batteries first*: the car gets what is left after the full rating of every
|
||||
battery that may still charge (switched on, not refusing, not full), less
|
||||
*Sun kept back*. So the car gets sun only when the batteries charge at full
|
||||
@@ -3354,18 +3354,18 @@ Both apply at once, with no restart.
|
||||
taken off the car first, down to 0 A if needed. While the batteries can
|
||||
still raise their output, the add-on first waits 15 seconds, so a cloud
|
||||
the batteries catch does not pause the car. It cuts at once when they
|
||||
cannot: already at full power, at the peak reserve or at their cut-out
|
||||
level. It also cuts at once in the last 2 minutes of the 15-minute period. A Solar
|
||||
charge never sets the month's peak.
|
||||
cannot: already at full power, at the peak reserve, at their cut-out
|
||||
level or refusing to give. It also cuts at once in the last 2 minutes of
|
||||
the 15-minute period. A Solar charge never sets the month's peak.
|
||||
- **Every way out of Solar leaves the charger at 0 A**: a stop or
|
||||
restart of the add-on (before the inverters go to 0 W), stopping control, a
|
||||
safety stop, shadow mode turned on, choosing Off, an unplugged car, a charger
|
||||
error or a stuck reading. If the charger does not take the 0 A, the add-on
|
||||
tries again a minute later, three times, then shows *Charger did not take
|
||||
it* and a warning. Once taken, nothing more is written. After the charger
|
||||
or Home Assistant was away, the
|
||||
add-on first sets 0 A, then starts again by the rules. A meter that stops
|
||||
gives a hold for *Pause after*, then 0 A. Choosing Manual leaves it to Manual.
|
||||
or Home Assistant was away, the add-on first sets 0 A, then starts again
|
||||
by the rules. A meter that stops gives a hold for *Pause after*, then 0 A.
|
||||
Choosing Manual leaves it to Manual.
|
||||
- Another writer stops the add-on's writes after 30 seconds, with an amber row
|
||||
and a warning, until you press the mode again or the charger shows the
|
||||
add-on's value again.
|
||||
@@ -3373,24 +3373,23 @@ Both apply at once, with no restart.
|
||||
`sensor.goodwe_car_today_solar_kwh`. Only the sun the car could take counts,
|
||||
not the battery or grid share of a hold, and not Manual.
|
||||
|
||||
**The car is never slowed for the peak limit in Manual.** A Manual charge goes on whatever
|
||||
the 15-minute peak does. With the default `ev_batt_cover` on, the batteries help
|
||||
cover it down to the peak reserve; a 3-phase 16 A charge (11 kW) can empty two
|
||||
batteries to the reserve in about 1.5 hours, and the month's peak then rises by
|
||||
what the car drew. When the car alone is why the batteries cannot hold the
|
||||
period, the add-on does **not** raise *Battery stopped limiting the peak* or
|
||||
*Load too high for battery*. It shows a grey note *Car over the peak
|
||||
**The car is never slowed for the peak limit in Manual.** A Manual charge goes
|
||||
on whatever the 15-minute peak does. With the default `ev_batt_cover` on, the
|
||||
batteries help cover it down to the peak reserve; a 3-phase 16 A charge (11 kW)
|
||||
can empty two batteries to the reserve in about 1.5 hours, and the month's peak
|
||||
then rises by what the car drew. When the car alone is why the batteries cannot
|
||||
hold the period, the add-on does **not** raise *Battery stopped limiting the
|
||||
peak* or *Load too high for battery*. It shows a grey note *Car over the peak
|
||||
limit* once per charging session, a grey row, and says so in the car's *Why*.
|
||||
This holds only while the car's reading is fresh and the charger's energy
|
||||
meter confirms it (the meter must have gained at least half of what the power
|
||||
adds up to over the last minute). A stale, stuck or frozen reading, or a
|
||||
charger with no energy entity, never hides a real overload of the house: the
|
||||
normal alarms stand. With `ev_batt_cover` off, the peak
|
||||
guard protects the house without the car, so it does not spend the batteries on
|
||||
it. Normal zero-grid control can still discharge them for the car, and a grid
|
||||
charge of the batteries can bring the period to the peak limit plus the car.
|
||||
The period can go over by the car alone. When the month's peak was set by a car
|
||||
charge, Home's peak line says so.
|
||||
This holds only while the car's reading is fresh and the charger's energy meter
|
||||
confirms it (the meter must have gained at least half of what the power adds up
|
||||
to over the last minute). A stale, stuck or frozen reading, or a charger with
|
||||
no energy entity, never hides a real overload of the house: the normal alarms
|
||||
stand. With `ev_batt_cover` off, the peak guard protects the house without the
|
||||
car, so it does not spend the batteries on it. Normal zero-grid control can
|
||||
still discharge them for the car, and a grid charge of the batteries can bring
|
||||
the period to the peak limit plus the car. The period can go over by the car
|
||||
alone. When the month's peak was set by a car charge, Home's peak line says so.
|
||||
|
||||
**When the charger does not answer.** After 30 seconds the card says *Charger
|
||||
not reachable* and one amber row appears. After 5 minutes one notification
|
||||
@@ -3432,8 +3431,9 @@ automation on.
|
||||
|
||||
**Home Assistant entities.** With MQTT the add-on adds the sensors
|
||||
`goodwe_car_power`, `goodwe_car_state`, `goodwe_car_today_kwh` and
|
||||
`goodwe_car_today_solar_kwh`, and the four controls named above. A saved ("retained") command is never applied, so a
|
||||
restart of Home Assistant cannot change the charger.
|
||||
`goodwe_car_today_solar_kwh`, and the four controls named above. A saved
|
||||
("retained") command is never applied, so a restart of Home Assistant cannot
|
||||
change the charger.
|
||||
|
||||
### Site
|
||||
|
||||
|
||||
@@ -448,31 +448,44 @@ class CarMixin:
|
||||
<= OWN_PAUSE_MAX_S
|
||||
return 0.0 <= mono - wr.phase_done_at <= OWN_PAUSE_TAIL_S
|
||||
|
||||
def _car_batt_able(self) -> bool:
|
||||
"""EV-05: can a battery still give power? One that is above its own
|
||||
cut-out level, not refusing to give and not under a safety stop."""
|
||||
def _car_giving(self) -> list:
|
||||
"""EV-05: the batteries that can give power now: above their own
|
||||
cut-out level, not refusing to give (SAFETY-73), not under a safety
|
||||
stop, and switched on (battery modes)."""
|
||||
out = []
|
||||
for inv in self.inverters:
|
||||
soc, floor = inv.soc, inv.bms_soc_floor
|
||||
if soc is None or floor is None or inv.sign_wd.tripped \
|
||||
or (inv.refused or 0) > 0:
|
||||
continue
|
||||
if self.modes_on and not self.pack_mode(inv).use:
|
||||
continue
|
||||
if float(soc) > float(floor):
|
||||
return True
|
||||
return False
|
||||
out.append(inv)
|
||||
return out
|
||||
|
||||
def _car_batt_able(self) -> bool:
|
||||
"""EV-05: can a battery still give power at all?"""
|
||||
return bool(self._car_giving())
|
||||
|
||||
def _car_batt_headroom(self, guard) -> bool:
|
||||
"""EV-05 round 4: can the batteries still RAISE their output? A
|
||||
battery above its cut-out (`_car_batt_able`), the guard neither
|
||||
saturated nor at the peak reserve, and the batteries' output more
|
||||
than `HEADROOM_W` under what they can give."""
|
||||
if not self._car_batt_able() or guard is None \
|
||||
or guard.saturated or guard.floor_limited:
|
||||
"""EV-05 rounds 4 and 5: can the batteries still RAISE their output?
|
||||
The guard is neither saturated nor at the peak reserve, and the units
|
||||
that can give (`_car_giving`) give more than `HEADROOM_W` under their
|
||||
own ratings (and under `guard.able_w` when the guard names it). A unit
|
||||
that refuses or is stopped counts neither in what is given nor in what
|
||||
could be."""
|
||||
giving = self._car_giving()
|
||||
if not giving or guard is None or guard.saturated \
|
||||
or guard.floor_limited:
|
||||
return False
|
||||
batt = self.site_batt_w
|
||||
top = guard.able_w if guard.able_w is not None else self.site_rating_w
|
||||
if batt is None or top is None:
|
||||
if any(inv.batt is None for inv in giving):
|
||||
return False
|
||||
return float(batt) < float(top) - HEADROOM_W
|
||||
batt = sum(float(inv.batt) for inv in giving)
|
||||
top = sum(float(inv.rating_w()) for inv in giving)
|
||||
if guard.able_w is not None:
|
||||
top = min(top, float(guard.able_w))
|
||||
return batt < top - HEADROOM_W
|
||||
|
||||
def _car_solar_pause(self, mono) -> bool:
|
||||
"""EV-05: Solar's own 0 A (a pause, the peak cut, the phase change)
|
||||
|
||||
@@ -1714,6 +1714,100 @@ for H in (25900.0, 25950.0):
|
||||
cut4 is not None and since4 is not None
|
||||
and cut4["t"] - since4 <= 1 and 900 in q4 and 900 in q4o
|
||||
and q4[900] <= 3400.0 and q4o[900] <= 3400.0)
|
||||
# =========================================================================== #
|
||||
print("\nROUND 5. HEADROOM COUNTS ONLY BATTERIES THAT CAN GIVE; EACH CLAUSE DECIDES")
|
||||
# =========================================================================== #
|
||||
|
||||
|
||||
def headroom_at(store):
|
||||
def f(p, c, t):
|
||||
g = c.peak_guard
|
||||
store[t] = (c._car_batt_headroom(g), c.site_batt_w,
|
||||
None if g is None else (g.saturated, g.floor_limited))
|
||||
return f
|
||||
|
||||
|
||||
def since_cut(r, t0):
|
||||
since = next((x["since"] for x in r["trace"] if x["since"] is not None
|
||||
and x["t"] >= t0), None)
|
||||
cut = first_cut(r, t0)
|
||||
return since, (None if cut is None else cut["t"])
|
||||
|
||||
|
||||
# R5a (review round 4 repro): A refuses to give from 850 (SAFETY-73), B gives
|
||||
# its full 4600 W; the house steps to 8000 W at 905 and 20 950 W at 908. Only
|
||||
# the full-rating clause, counted over the units that can give, decides: the
|
||||
# guard is neither saturated (its rating still counts A) nor at the reserve.
|
||||
def _refuse_a(p, c):
|
||||
if not getattr(p, "_a_held", False):
|
||||
p._a_held = True
|
||||
orig = p.batt_of
|
||||
p.batt_of = lambda u, at, _o=orig: (min(_o(u, at), 0.0) if u == "a"
|
||||
else _o(u, at))
|
||||
[i for i in c.inverters if i.name.endswith("a")][0].refused = 1
|
||||
|
||||
|
||||
hh5 = steps((0, 500.0), (905, 8000.0), (908, 20950.0))
|
||||
EV5 = {t: _refuse_a for t in range(850, 1810)}
|
||||
hr5 = {}
|
||||
r5a = S.drive(house=hh5, sun=const(13000.0), first="car", socs=ABLE,
|
||||
dur=1810, opts={"slew_w": 0}, events=dict(EV5),
|
||||
on_cycle=headroom_at(hr5))
|
||||
r5ao = S.drive(house=hh5, sun=const(13000.0), first="car", socs=ABLE,
|
||||
dur=1810, opts={"slew_w": 0}, events=dict(EV5), mode="off")
|
||||
q5 = {q: g for q, g, _c in quarters(r5a, 3400.0)}
|
||||
q5o = {q: g for q, g, _c in quarters(r5ao, 3400.0)}
|
||||
s5, c5 = since_cut(r5a, 905)
|
||||
# B can still raise its output for a few seconds after the first step; the
|
||||
# moment it gives its full rating there is no headroom, and the cut must come
|
||||
# then, not 15 s after the guard first wanted power.
|
||||
nohead5 = next((t for t in sorted(hr5) if t >= 905 and not hr5[t][0]), None)
|
||||
sat5 = None if nohead5 is None else hr5[nohead5][2]
|
||||
check(f"R5a/N4 battery A refuses to give, B at its full 4600 W: headroom ends "
|
||||
f"at {nohead5} (guard (saturated, floor-limited) {sat5}), the cut comes "
|
||||
f"then, not 15 s after the guard first wanted power (wants from {s5}, "
|
||||
f"cut at {c5}), and the period lands under the aim like the car-Off "
|
||||
f"twin ({round(q5.get(900, -1))} W vs {round(q5o.get(900, -1))} W)",
|
||||
s5 is not None and c5 is not None and nohead5 is not None
|
||||
and c5 <= nohead5 + 1 and c5 - s5 < 15 and sat5 == (False, False)
|
||||
and q5.get(900, 1e9) <= 3400.0 and q5o.get(900, 1e9) <= 3400.0)
|
||||
|
||||
|
||||
# R5b: the wait itself. The batteries have headroom but answer slowly (20 s),
|
||||
# so the guard wants power for more than 15 s: the cut comes at 15 s, not
|
||||
# earlier and not never.
|
||||
def _slow(p, c):
|
||||
p.response_s = 20.0
|
||||
|
||||
|
||||
hr5b = {}
|
||||
r5b = S.drive(house=steps((0, 500.0), (910, 6000.0)), sun=const(2900.0),
|
||||
first="car", socs=ABLE, dur=960, events={900: _slow},
|
||||
on_cycle=headroom_at(hr5b))
|
||||
s5b, c5b = since_cut(r5b, 905)
|
||||
check(f"R5b: the batteries keep their headroom while the guard wants power "
|
||||
f"(wants from {s5b}, headroom {[hr5b[t][0] for t in (912, 920, 925) if t in hr5b]}"
|
||||
f"): the cut comes 15 s later, not sooner and not never (cut at {c5b})",
|
||||
s5b is not None and c5b is not None and 15 <= c5b - s5b <= 16
|
||||
and all(hr5b[t][0] for t in range(int(s5b), int(c5b)) if t in hr5b))
|
||||
# R5c: the peak reserve alone decides: both batteries at 19 % (above their
|
||||
# 10 % cut-out, under the 20 % peak reserve), the car at 6 A, the house to
|
||||
# 9 kW. The guard is floor-limited, not saturated, and the batteries' output
|
||||
# is still under their rating: the cut comes at once.
|
||||
hr5c = {}
|
||||
r5c = S.drive(house=steps((0, 500.0), (300, 9000.0)),
|
||||
sun=steps((0, 2300.0), (180, 2000.0)), first="car",
|
||||
socs={"a": 19.0, "b": 19.0}, dur=420,
|
||||
on_cycle=headroom_at(hr5c))
|
||||
s5c, c5c = since_cut(r5c, 290)
|
||||
st5c = hr5c.get(c5c) if c5c is not None else None
|
||||
check(f"R5c: floor-limited alone decides (guard (saturated, floor-limited) "
|
||||
f"{None if st5c is None else st5c[2]}, batteries giving "
|
||||
f"{None if st5c is None or st5c[1] is None else round(st5c[1])} W): the "
|
||||
f"cut comes at once (wants from {s5c}, cut at {c5c})",
|
||||
s5c is not None and c5c is not None and c5c - s5c <= 1
|
||||
and st5c is not None and st5c[2] == (False, True)
|
||||
and st5c[1] is not None and st5c[1] < 9600.0 - 100.0)
|
||||
print("\n(T39, T44, T45, T50 and T51, the long runs, are in test_ev05_long.py)")
|
||||
|
||||
print()
|
||||
|
||||
@@ -60,6 +60,7 @@ class SunPlant:
|
||||
self.batt_nan = set() # units whose battery figure reads None
|
||||
self.utc_off = 0.0 # the wall clock jumps, the model clock not
|
||||
self.ha_down = False # Home Assistant answers nothing (SAFETY-112)
|
||||
self.response_s = RESPONSE_S # a slow battery takes longer
|
||||
|
||||
def batt_of(self, u, at):
|
||||
w = 0.0
|
||||
@@ -131,7 +132,7 @@ class SunPlant:
|
||||
if e == SET:
|
||||
return self._logged("current", float(v), self.ch.request_current)
|
||||
if e.startswith("number.sp_"):
|
||||
self.hists[e[-1]].append((self.t + RESPONSE_S, float(v)))
|
||||
self.hists[e[-1]].append((self.t + self.response_s, float(v)))
|
||||
return True
|
||||
|
||||
|
||||
|
||||
Reference in New Issue