Claude 8953be0362 SAFETY-137: the shutdown and Stop 0 W is the last write every unit hears
checks / unit (pull_request) Successful in 22m59s
infra-pin / fresh (pull_request) Successful in 1s
The 0 W of shutdown and of the Stop button now waits (bounded, 2 s) for a
write already on its way to the same unit, for every driver, GoodWe included.
Once shutdown has begun, cycle, heartbeat and safety-stop writes are dropped
right before the write is created. One shared wait (_await_inflight) serves
the 0 W and SMA-10's _release_last.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-08 02:39:38 +01:00
glenn schrooyenandClaude 313503724d SMA-10 round 3: Start clears a failed hand-back streak; the hook is tested
checks / unit (pull_request) Successful in 23m23s
infra-pin / fresh (pull_request) Successful in 2s
When control takes the unit again, release_fails, release_retry_at and
release_zero_sent are reset, so the next Stop is a new streak with its own one
0 W, error line and event. Tests: a streak that Start interrupts without a
recovery; a driver that overrides release_fallback(). _BACK_NL "de eigen
sturing" (round 2) is kept.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 21:31:28 +01:00
glenn schrooyenandClaude d26cc573fe SMA-10 round 2: a failed release sends 0 W once, retries at heartbeat pace
checks / unit (pull_request) Successful in 23m37s
infra-pin / fresh (pull_request) Successful in 2s
When release() fails (False, raises or hangs past RELEASE_BUDGET_S) the unit
gets one bounded write(0) through the new Driver.release_fallback() hook
(default write(0)), then nothing more, so the inverter's own fallback timer is
not reset. The release is retried once per heartbeat, not on every idle
write. One error line and one action-log event per failure streak, one line on
recovery. Dutch default "terug naar de eigen sturing". DECISIONS says what a
unit is left at.

test_messages.py: the RELEASE_BUDGET_S data entry is gone again (the line
that needed it is gone).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 20:17:01 +01:00
glenn schrooyenandClaude a1be9c48b3 SMA-10: two idle states, hold 0 W or hand the inverter back
checks / unit (pull_request) Successful in 24m9s
infra-pin / fresh (pull_request) Successful in 1s
A driver now says whether its release() hands the inverter back
(Driver.hands_back; GoodWe is False, so release() stays write(0) and the
Controller never calls it). command_site_release() sits next to
command_site_zero(): the Stop button and shutdown() (so SIGTERM, restart,
control task death and a late config refusal) hand a hand-back unit back,
once, and zero every other unit as before. Safety stops and refusals still
hold 0 W for every unit. Shadow mode releases a hand-back unit. After a
release nothing is written to the unit (heartbeat and cycle included) until
control starts again. release() is bounded by RELEASE_BUDGET_S (= the write
budget), runs concurrently per unit, and a raising or hanging release on one
unit does not stop the others.

The "set to 0 W" sentences for Stop, restart, shadow mode and the stopped
banner are built from the roster (app/handback.py, EN and NL, words from the
driver); a GoodWe-only roster keeps every old literal. A handed-back unit
shows "Back under <its control>" on Home.

Existing test edited: test_messages.py (two classification entries for the
CRITICAL line that moved into a roster builder, and the new release bound).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 18:21:28 +01:00
glenn schrooyenandClaude e56eeef8f0 SMA-2: each inverter is reached through a driver; GoodWe behaviour unchanged
checks / unit (pull_request) Successful in 23m14s
infra-pin / fresh (pull_request) Successful in 2s
app/drivers.py holds one Driver per roster entry (configured, actuator_id,
limits, read, write, release, probe, link_stale_s, batt_bound, settle_s, brand,
words). GoodWeEsphomeDriver makes the calls the code it replaced made, in the
same order. Inverter gets driver; has_writer, is_live and link_note read it. The
SoC/power read, the write, the device range (run_control, amain, the settings
panel), rule 2 per unit and the SAFETY-28 census go through it.

setpoint_entity is optional per entry beside driver, host, port, unit_id and
maintenance; only goodwe_esphome is selectable, the rest are checked and unused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 11:28:47 +01:00
glenn schrooyenandClaude 4f96397a60 Merge origin/master (0.20.1) into release/1.0
checks / unit (pull_request) Successful in 32m4s
infra-pin / fresh (pull_request) Successful in 2s
Brings OPT-36 (#229) and TEST-37 (#231) onto release/1.0, which keeps
SAFETY-128 (#228). No textual conflicts. CHANGELOG: the SAFETY-128 entry
moved out of the released 0.20.0 section into "Not in a release yet" above
## 0.20.1; the 0.20.0 and 0.20.1 sections are identical to master.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-05 18:34:34 +01:00
glenn schrooyenandClaude e4b9dee699 OPT-36 round 3: B's charge counts the cheap time left; OPT-34 nights on their own shapes
checks / unit (pull_request) Failing after 36m29s
infra-pin / fresh (pull_request) Successful in 2s
The run is sized at the batteries' ratings, not the peak limit, so a run too
short to fill a Cheap hours battery is planned again later in the night.
Counting that run alone made B's give grow through the night and A's level
fall after A had bought (round 2: 55 -> 69 -> 41 -> 37 %, A to 56 %).
dayplan._cheap_give_kwh() now also counts the later firm slots before the
expensive hours that a run would still be worth charging in (price + the
spread control asks at most the give run's dearest slot); the Controller
passes the slots and the spread.

test_opt34: back to the original house shapes, fixture and expected values.
B is Off in the nights that test A's level (a Cheap hours B now covers
these hours); B's checks run in new `_b` nights; the 03:00 check runs in a
night from midnight; tail starts A at 60 %; late_fresh reads the kept 6.0.
test_opt36: slot cases, a whole night on one figure (level never moves),
F-1 with B counted (raised level reached and held). test_ux54: the run end
is read from the plan and asserted (02:30); the F1/F2 sweep uses a peak
limit that does not bind and reads a level shown as the target as at it.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-02 10:15:20 +01:00
glenn schrooyenandClaude d3f4f9f48b SAFETY-128 round 2: find late readings from the batteries, not the meter alone
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
Review B1: the meter fit took repeating house loads (ovens, a heat pump)
for late readings on healthy 1-2 s sites, about 9 % of the recorded
house. B2: at a 5 s meter it never ran. M1: no hysteresis. M2: an
unbounded check.

lateness.Delay now fits how long each battery's reading takes to show
its own request, which the house does not move, from the 1 s reads
(read_inputs -> Answer.watch). The meter fit stays for speed at 1-3 s
meters, but counts only when an ask was slow to start and no battery
fit said on time. Late from 9.5 s after 2 fits, on time under 6.5 s,
dropped after 120 s without a fit. Fits are bounded (a few ms).

Readings on time: no verdict in any reviewer scenario (22 shapes at
1/2/5 s meters, 7 harm runs) nor in 2 days of the recorded house at
1, 2 and 5 s ticks; digests equal to 77fe31b. Late: found 36-68 s after
the start at 1-2 s, about 3 min at 5 s. The row gives the batteries'
delay, or no figure while only the meter has shown it.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-02 04:32:04 +01:00
glenn schrooyenandClaude 05746c0564 OPT-36: Leftover solar counts what Cheap hours and Solar first batteries will give before buying
checks / unit (pull_request) Failing after 59m31s
infra-pin / fresh (pull_request) Successful in 2s
Live 0.20.0: A (Leftover solar, 60 %) charged to 95 % while B (Cheap hours,
94 %) already covered the expensive hours. dayplan.plan() now takes off the
shortfall what Cheap hours batteries will hold when the hours start (the
ceiling or what their cheap run reaches under the peak aim) and what Solar
first batteries will still hold after the night's use. Home reads a give
block after the planned charge, plan_cover() is the plan's own figure, and
the Why line says other batteries cover.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-02 02:03:04 +01:00
glenn schrooyenandClaude 09e1fbb898 SAFETY-128: control does not act on late Home Assistant readings
checks / unit (pull_request) Successful in 19m36s
infra-pin / fresh (pull_request) Successful in 1s
Readings that Home Assistant delivers late but still changing passed
every staleness gate, so the loop corrected again each cycle an error
its last command had already fixed (10 s late: the give run swung and
exported to -1.9 kW), and the peak guard pushed to the inverter limit
on the same late figures (OPT-34 F-2).

app/lateness.py fits how long after a power request the meter shows
it. Over 8 s the readings are late: a request the battery reading has
not answered holds the loop (it may not lead the reading by more than
100 W) and caps the peak guard at what stands; unanswered for 23 s it
holds, then 0 W after stale_input_s. An amber row and one log line per
episode say so. With readings on time nothing changes (digests equal).

DECISIONS/SAFETY-128-late-readings.md; test_safety128.py.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-01 23:45:03 +01:00
glenn schrooyenandClaude bb57a85b35 OPT-34 round 3: the latch ends on time, with the run, with the mode, and with the night
checks / unit (pull_request) Successful in 20m15s
infra-pin / fresh (pull_request) Successful in 1s
- F1: an expired latch is dropped whatever the run state; plan_targets() and the
  store loader ignore one that has ended (no stale latch after a restart).
- F2: the "charge goes on" line only while a cheap run is on.
- F3: a battery that is off or no longer Leftover solar leaves the latch.
- F4: a run carries the latch on only if it starts by the bell start (06:00
  local) after the latch began (manager's call, 2026-10-31).
Tests: test_opt34 scenarios stale/stale_live and part 5; test_modes_p4 asks at a
moment inside the latch.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-31 23:04:36 +01:00
glenn schrooyenandClaude eee7616022 OPT-34 round 2: the latch follows the plan, up or down, and drops what left it
checks / unit (pull_request) Successful in 18m37s
infra-pin / fresh (pull_request) Successful in 1s
While a forecast is present and the cheap run holds, the night-charge latch is
rebuilt from the plan: a latched battery takes its current level whatever its
role this tick (a fresh figure may lower it below the SoC), one that left the
plan is dropped, a new one comes in only while it charges from the grid.
Test: a fresh brighter figure lowers A below its SoC, the sensors go quiet, A
does not charge back up. CHANGELOG summary says two fixes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-31 19:17:20 +01:00
glenn schrooyenandClaude 412e47f111 OPT-34: the night charge keeps its level when the kept forecast ends
checks / unit (pull_request) Successful in 18m59s
infra-pin / fresh (pull_request) Successful in 1s
With the forecast sensors silent from 17:05 the kept evening figure ended at
midnight + 3 h, in the middle of the night grid charge, and Leftover solar's
planned level went with it (rig: A 49.8 % against 79.9 %).

- A night grid charge that has started keeps its planned level when the forecast
  goes (Controller._latch_charge, store key night_charge_latch), and the narrow
  price gap with it (weather_held). A fresh figure still moves the level.
- The evening's tomorrow figure is today's until the bell starts (06:00 local),
  up to 15 h old but only if it was usable at midnight (solarfc.Hold.stand_in).
- Screen: "No solar forecast now. The charge under way goes on to its planned
  level." (EN/NL) while a latched battery is below its level.
- test_opt34.py (whole nights through the real control cycle, mutants), test_opt27
  and test_modes_p4 adjusted to the new window and the kept level.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-31 17:00:31 +01:00
glenn schrooyenandClaude 40595e42ae SAFETY-126: a landing error on the aim is not an overrun
During the night grid charge under the peak reserve the guard alarmed
(ERROR PEAK_GUARD_FLOOR_LIMITED, "Battery stopped limiting the peak") and the
Batteries "Why" said "The peak limit needs power" at quarter ends, while every
quarter landed on the aim. The charge lands the period 0-7 W over the aim and
excess_w()'s 900 / remaining turns that into tens of kW in the last second;
with nothing able to give, check_peak_floor_limited() alarmed on any
wanted > 0.

Each cycle the guard wants power, _peak_landing() asks misses_aim(): with the
batteries at 0 W, does the period end more than ALARM_MISS_W over the aim? If
not, the decision is within_aim: no reserve alarm, no red peak row, no "Why"
peak. The claim and the commands are unchanged. A real overrun under the
reserve alarms on the same cycle as before.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-31 01:26:02 +01:00
glenn schrooyenandClaude 50b567d6d1 OPT-27: the night plan keeps the last fresh solar forecast
Forecast.Solar's sensors stop updating in the evening, so at night every such
site had no forecast: the night cheap run needed 1.5x the cycle cost and
Leftover solar planned nothing. One missed poll also dropped it at once.

solarfc.Hold keeps the last fresh reading of each sensor, for the day it is
for. A missing or stale sensor is covered by it for up to FRESH_S (a short
outage), and from the end of the bell (20:00) until local midnight + 3 h
however old. A tomorrow figure is tomorrow's until midnight and then today's;
a today figure is only today's. Stored in the controller's store
(solar_fc_hold), so an evening restart keeps it. The forecast line says
'Solar forecast read 17:05, used for tonight's plan.' (EN, NL).

test_tariff24_weather.py runs with a hold that never covers: it tests what the
plan does when the forecast IS lost.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-30 18:54:41 +01:00
glenn schrooyenandClaude 8bf54ece3d Merge master (0.19.2, f1c9733) into sync-0.19: TARIFF-24 and SAFETY-125 reach release/1.0
Brings in 0.19.1 (TARIFF-24) and 0.19.2 (SAFETY-125). Git merged every file
without a text conflict. config.yaml's version becomes 0.19.2, the newest
CHANGELOG section: test_version_gate.py (PKG-14, 11b) requires the two to be
equal, and release/1.0 took 0.19.0 the same way (#207). The 0.19.1 and 0.19.2
CHANGELOG sections come in as history.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-30 08:09:44 +01:00
glenn schrooyenandClaude 2929ece7da SAFETY-125 round 2: the one-inverter maintenance charge is sized to the room too
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 1h0m42s
Owner 2026-10-29: fix N=1 in this hotfix. _charge_headroom() no longer
returns early at one inverter, so the N=1 cheap-window maintenance charge
is held to charge_room_w() as at N=2; SAFETY-84's site-stop rule stays N>=2
only (at N=1 such a stop outranks the shaping anyway). The guard no longer
steps in and gives power at each quarter's end during that charge.

test_safety125.py: N=1 maintenance on 5 s and 10 s meters with late
readings, with and without a banked peak; the row in an N=2 maintenance
charge and in shadow mode; edge cases (blind past the hold, a start
mid-quarter, the summer-time change, the forecast in W, a 10 s meter, the
last second). test_safety84/87: three N=1 pins move. test_safety119: its
quarter-edge hand-back runs keep the old N=1 sizing as a fixture, plus a
check that with the new sizing nothing hands back. CHANGELOG, DECISIONS,
DOCS follow.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-29 14:57:39 +01:00
glenn schrooyenandClaude 88ab8a50e3 SAFETY-125: a grid charge counts a late meter reading's seconds; the guard row says "over" when it is
checks / unit (pull_request) Successful in 56m44s
infra-pin / fresh (pull_request) Successful in 1s
A meter reading late near a quarter's end left seconds the projection did
not count (SAFETY-99), and charge_headroom_w() read them as room: the cheap
run (and price trading, and the N=2 maintenance charge) went back to full
power in the quarter's last seconds and the quarter could land over a banked
month peak or the cap. peakguard.charge_room_w() counts those seconds at the
held reading for the charge only; the guard's floor is unchanged.

The guard row said "idle, heading for 5 814 W, under this month's 5 413 W
peak". Over the limit at the current rate the row and the month-peak line
now say so, and that the grid charge is cut back.

Version 0.19.2, CHANGELOG, DECISIONS. test_safety125.py new; the lag pins
in test_price_run_fixes.py and test_opt20.py and the AST pin in
test_arbitrage.py follow the change (see the pull request).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-29 02:08:38 +01:00
glenn schrooyenandClaude 97686319f3 TARIFF-24 round 3: a run planned with a forecast keeps its gap to its end
checks / unit (pull_request) Successful in 51m57s
infra-pin / fresh (pull_request) Successful in 1s
Losing the solar forecast mid-run used to widen the gap at once and stop a
grid charge (and a sensor that went unavailable for a minute stopped and
restarted it). A run under way when the forecast is lost now keeps the gap it
was planned with until it ends (Controller.weather_held(), recorded by
_wx_track() each cycle a forecast is read); the wider gap applies from the next
run. The plan key holds the hold state so the plan rebuilds when it ends. Home's
mirror (homeview.trade_verdict) asks the same weather_held(now).

Tests: test_tariff24_weather.py part 4 (going: the charge continues to the run's
end, the next run is not_worth; flap of one and two reads: no stop, no restart;
Home agrees) and a test_modes_p4.py scenario that runs a forecast day at a gap
between 1x and 1.5x the cycle cost. DECISIONS wording follows.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-28 17:17:56 +01:00
glenn schrooyenandClaude 382b0ea411 TARIFF-24 round 2: a usable solar forecast replaces the "no weather" x1.5 (AUDIT-02 F1)
With battery modes on, the price gap a mode needs was always widened x1.5 by
Uncertainty.NO_WEATHER, even with a solar forecast read, so a 0.08 day/night
gap never traded at the shipped cycle cost. The doubt is now added only when
no usable forecast is read (solar_fc is None, the day plan's own test), in the
run plan (_price_runs), the charge gate (_mode_roles) and Home's mirror
(homeview.trade_verdict). The rule is one helper, arbitrage.weather_uncertainty();
the modes-off trade path (main.py cycle) keeps its literal NO_WEATHER.

DOCS "Battery modes" sentence, CHANGELOG 0.19.1 line and the DECISIONS note
follow. Tests: test_tariff24_weather.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-28 15:08:21 +01:00
glenn schrooyenandClaude d667f3f3a8 TARIFF-24: battery modes start the tariff task (hotfix 0.19.1)
With battery modes on, a day/night or fixed static_profile, no price feed and
arbitrage off, tariff_refresh_wanted() was false: no tariff task, no
tariff_plan, mode_runs None, so Leftover solar / Cheap hours never charged from
the grid and the Batteries screen said "No prices". packmode.enabled(opts) is
now a third term of the gate. With price_provider off the task is pure
arithmetic on static_profile, so no HTTPS call is added.

Also: version 0.19.1, CHANGELOG entry, DECISIONS note, test_tariff24.py, and a
shorter tariff_refresh_wanted() docstring (history stays in DECISIONS).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-28 01:02:32 +01:00
glenn schrooyenandClaude b6b2d1b184 UX-54: a Forecast tab with the sun, the house and each battery's level, per hour
checks / unit (pull_request) Successful in 48m29s
infra-pin / fresh (pull_request) Successful in 1s
A new tab beside Home and Batteries for today and tomorrow: the solar
forecast, the solar measured so far, the house's expected use and each
battery's expected level, with the plan's own charge and give blocks under it.

- Blocks are Home's: today's are the plan's `runs`, tomorrow's come from the
  same builders (`homeview.runs_for()`), in the plan lines' words.
- The sun is what solarfc reads; a daily total is spread over the bell and the
  tab says so. The house is HouseProfile.estimator(), as the plan reads it.
- The level is new: `daycurve.curve()` gives each battery the role
  `modetrade.decide()` gives it and moves it hour by hour inside the plan's
  floor and ceiling. It is an estimate and counts on `solar_trust_pct`.
- Built on request (`GET forecast`), no Home Assistant call. Measured solar is
  kept per hour in memory from the reading control already takes.
- A part not known yet is a note: modes off, no forecast, learning, no
  forecast for tomorrow, a monthly cycle, no level, stopped, shadow.

No decision, command, timing or option key changes. Found, not changed:
`dayplan.plan()` over-counts a state-only forecast (DECISIONS/UX-54).

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-26 19:38:59 +01:00
glenn schrooyenandClaude 242cf434f4 UX-53: Home draws a grid charge only where the add-on will take it
checks / unit (pull_request) Successful in 48m7s
infra-pin / fresh (pull_request) Successful in 2s
Modes on: Controller._mode_roles() files the trade gate it just asked as
mode_gate; while it refuses, Home draws no grid charge and marks no cheap
quarter. Modes off: a charge after the last dear period is asked of the same
gate at its own start (homeview.leg_taken) and dropped when refused there.
Words: "Lowest/Highest price left" (EN, NL); a flat remainder on a dynamic or
day/night site is no longer called a fully fixed product.

No change to control decisions, commands or options.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-26 11:15:29 +01:00
glenn schrooyenandClaude 4297f7f3f1 PRICE-02: the trading verdict skips price periods that have ended
checks / unit (pull_request) Failing after 48m38s
infra-pin / fresh (pull_request) Successful in 1s
TariffPlan.arbitrage(now=...) drops the points whose period has ended
(end <= now), so the cheapest and dearest point can still be traded.
decide() (modes off), the modes-on allowed() gate and the Home verdict
all pass their own now. Hourly feeds and the static tariff are unchanged.
The off-peak sentence and the charge/discharge sentences say "price
period". Tests: test_price02.py; test_arbitrage.py rolls its whole-day
plans to start at now; test_modes_p3.py part 1 digests leave the trade
sentence out (commands unchanged on 7a00f12, 90bc901 and this tree).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-22 07:19:28 +02:00
glenn schrooyenandClaude Opus 5.5 ae0ef4296b UX-46 review: Dutch wording fixes on the NL rows and notes
checks / unit (pull_request) Successful in 45m44s
infra-pin / fresh (pull_request) Successful in 1s
Text only. "stroom te opnemen" -> "stroom op te nemen"; Developer Tools is
"Ontwikkelhulpmiddelen" in HA and ui_text; the green stuck-meter row no longer
starts "Vastgelopen meter:"; maintenance banner names the phase in Dutch;
double "dan" in the device note; plainer peak reserve, peak guard, refused
commands and missing-entity wording. Two stale comments now say the banner
and Home bodies follow the page's language.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-22 04:56:30 +02:00
glenn schrooyenandClaude 7a392a5367 UX-46: Dutch status rows, banners, notes and wizard lines on the NL pages
Rows and banners are built once with their Dutch beside them (messages.Bi)
and status_payload() picks one by the page's language. Settings notes and the
wizard's checks carry a Dutch twin (Note.nl) that /config/validate picks by
the posted language. The peak forecast label drops "(W)" in EN and NL.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-22 03:21:41 +02:00
glenn schrooyenandClaude 8bf25696cb SAFETY-121: a recurring overload warns every quarter
checks / unit (pull_request) Successful in 44m51s
infra-pin / fresh (pull_request) Successful in 1s
TEST-23 F-1: on a 5 s meter a steady overload warned once in 70 min. The
loop was at its bound 4-5 cycles a quarter, all inside SAFETY-119's settle
of 12 cycles (60 s) and under its budget of 8 per 900 s. The simulation
fed the meter a cycle behind the battery reading, so the guard and the
charge chased each other and gave ~20 bound cycles a quarter.

The settle is now 4 cycles and 22 s (HANDBACK_CYCLES, SHORT_SPAN_S), and
the rolling budget one number, 11 per 900 s, at every cycle length. The
cycle length is no longer tracked. Commands unchanged; the re-pinned
digests of test_safety84/87 differ from bee7431 in OUTPUT_CLAMP rows only.
test_safety119 runs the rig's shape (meter in the same cycle) at 1-15 s
and checks a stop keeps the budget (review F2, X3).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-21 10:09:14 +02:00
glenn schrooyenandClaude 6fd0fa05f1 SAFETY-119 round 3c: the hidden-bound budget follows the cycle length
checks / unit (pull_request) Successful in 43m29s
infra-pin / fresh (pull_request) Successful in 1s
No single rolling budget met both cases in the sweep (8 false-alarmed on
2 s seed 25 and warned in 1 to 3 of 7 quarters at 15 s). The budget is
now 10 cycles up to a 3.5 s cycle, 8 up to 11 s, 6 up to 16 s, 4 beyond,
per rolling 15 minutes; 8 while the cycle length is unknown. A stop or a
gap over two minutes is not a cycle length. The unsourced "owner
accepted N=8" paragraph is removed from DECISIONS. test_safety119 part 4
now runs 2 s seed 25 and shows a fixed budget of 8 warns there; the
never case runs at 2 s and checks every other quarter at 15 s.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-21 00:57:43 +02:00
glenn schrooyenandClaude e27e62ff72 SAFETY-119 round 3b: no-clock budget, fixed-seed tests, accepted limits
checks / unit (pull_request) Successful in 43m1s
infra-pin / fresh (pull_request) Successful in 1s
The rolling budget now holds without a monotonic clock (it never refills).
Quarter-edge tests use seeds 1-3 at 2, 5, 10 and 15 s (no hand-picked seeds).
Re-pin comments point at part 6. DECISIONS lists the limits the owner
accepted with N=8 on 2026-10-20.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-20 20:46:14 +02:00
glenn schrooyenandClaude 103db2fcda SAFETY-119 round 3: rolling 15-minute budget for the hidden integrator bound
checks / unit (pull_request) Successful in 42m33s
infra-pin / fresh (pull_request) Successful in 2s
At most 8 hidden bound cycles in any 900 s across all hand-backs, replacing
the per-run budget. Chosen from a sweep (N 3 to 10, 1 to 15 s meters, both
cases); DECISIONS has the table. Tests: never case at 5, 10, 15 s, quarter
edge at 2, 10, 15 s, the rolling budget at its boundaries.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-20 17:27:43 +02:00
glenn schrooyenandClaude e76c70ecb0 SAFETY-119 round 2: one settle window per run of hand-backs
checks / unit (pull_request) Failing after 42m32s
infra-pin / fresh (pull_request) Successful in 2s
A hand-back used to restart the window, so a guard and a charge taking
turns hid the loop's integrator bound for good (0 warnings in 2 h; 28
before the fix). A run of hand-backs (the wire away less than a settle
between them) now hides the bound for at most 11 bound cycles and 22 s in
all, then it counts. The quarter-edge kick stays hidden. No command or text
changes. Tests for the two reviewer mutants that only unit checks caught
(a restart counted as a hand-back; span only), DECISIONS gives the delay at
2 s, 5 s and 60 s. test_safety87.py:543 shortened.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-20 00:52:24 +02:00
glenn schrooyenandClaude c4e15ec4cd SAFETY-119: no "not keeping up" when the loop takes the wire back
When the peak guard or a maintenance charge hands the wire back, the loop's
integrator is re-seeded from that owner's command and kicked by a meter that
does not show it yet. It crossed its rail for a cycle or two and raised
goodwe_integrator_bound while the battery gave what it was told.

The loop's integrator bound is not counted until the plant's settle
(SHORT_CYCLES, SHORT_SPAN_S) has passed since the hand-back. An over-rating
always counts; a bound that lasts warns after the settle. No command
changes and no text changes. test_safety119.py; DECISIONS entry.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 14:14:08 +02:00
glenn schrooyenandClaude fd08090360 DOC-8: say EMS port, not meter bus
checks / unit (pull_request) Successful in 40m22s
infra-pin / fresh (pull_request) Successful in 1s
The add-on is wired to the inverter's RS485 port labelled EMS. Reword
README, DOCS, config description, field guide source and HTML. The HA
manufacturer string is left unchanged: test_mqtt pins it byte for byte.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-17 01:09:42 +02:00
glenn schrooyenandClaude 7d52dc1c0f SAFETY-118: a missing peak forecast reading keeps the unit-fault state
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 40m19s
A missing reading (unavailable, unknown, failed read, non-numeric) no longer
clears the fault: no false 'used again' INFO, no repeated WARNING, the status
row stays. Adds pv.has_reading(). DECISIONS wording fixed; tests added.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 18:19:44 +02:00
glenn schrooyenandClaude f0b4e68e49 SAFETY-118: read the peak forecast in its own unit
checks / unit (pull_request) Successful in 40m20s
infra-pin / fresh (pull_request) Successful in 1s
peak_forecast_entity is read through pv.watts() by its unit_of_measurement;
the abs(raw) < 50 size rule is gone. No unit or a non-power unit means the
forecast is not used, with one warning per cause. The validator no longer
claims a kW sensor is taken as watts for this entity.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 16:00:34 +02:00
glenn schrooyenandClaude 06339a2446 OPT-20: a refusal probe asks only PROBE_W, not the whole trade
checks / unit (pull_request) Failing after 40m47s
infra-pin / fresh (pull_request) Successful in 1s
The probe's trade was sized at the probing battery's rating. Its SAFETY-73
pin held 200 W of that, and the allocator put the rest on a battery with no
mode range (one in a maintenance phase): TEST-23 OPT-15 g7, -2300 W on A in
its maintenance charge for 34 s, grid 3100 W.

modetrade.decide() now asks PROBE_W for the probing battery plus what the
other chargers would have had without the probe; size() adds the probe on top
of their share, or files PROBE_W exactly, or nothing. _mode_trade() carries
the pin only on the ticks it is filed, so the window's first and last cycle
do not move another battery's share either. Modes off and modes on with no
probe are unchanged (bf9019e digests). Tests: test_opt20.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-15 13:08:59 +02:00
glenn schrooyenandClaude c68fd275cc PRICE-01 round 3: replace the fixed-tariff notification with a log line and a settings note
checks / unit (pull_request) Successful in 39m6s
infra-pin / fresh (pull_request) Successful in 1s
G1: remove the false 'Fixed tariff not used' notification. One INFO line at
start and an info note beside the setting (EN/NL) when price_service has a
non-blank static_profile; the old notification id is dismissed at start.
DOCS, migration step 5 and DECISIONS rule 7 now say what the code does.
S05: whitespace-only static_profile counts as not set.
G2: maintenance_enabled read through MaintConfig.from_options().

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 20:27:15 +02:00
glenn schrooyenandClaude 0801776645 PRICE-01 round 2: the token on no page, fixed-tariff note, token length, F3 words, test gaps
checks / unit (pull_request) Successful in 39m0s
infra-pin / fresh (pull_request) Successful in 2s
F1: every password option is shown as ******** (set) or empty in /config/model
(options, running, ui) and in a stale refusal; the classic page draws it as a
password field; a save or validate that sends ******** or nothing keeps the
stored value. F2: a static_profile beside price_service is said once at start
(notification and log), not refused. F3 (owner, 2026-10-14): the no-price row,
Home line and notification only while maintenance_enabled is on. F4: tests for
the reviewer's R01 and R10. F5: price_service_token must be 16+ characters.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 18:56:51 +02:00
glenn schrooyenandClaude 87ad958842 PRICE-01: Dutch dates, no redirects with the token, more checks
checks / unit (pull_request) Successful in 39m2s
infra-pin / fresh (pull_request) Successful in 1s
- The notification, status row and Home line name an earlier day in the
  language of the text ("13 okt om 21:00"); the Dutch title is "Prijzen
  ontbreken", so the body no longer repeats it.
- The token request does not follow redirects: the host is fixed in code.
- A step back up to the saved prices is one INFO line.
- Tests: whole status payload free of the token, a redirect, the 5-decimal
  edge of the old average, modes plan equal to generic_dayahead's.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 16:54:11 +02:00
glenn schrooyenandClaude 9ac3a9d2bc PRICE-01: price_service provider, fallback chain, and the gate read from it
checks / unit (pull_request) Successful in 39m31s
infra-pin / fresh (pull_request) Successful in 1s
A new price source, `price_provider: price_service`: the owner's price server,
one fixed HTTPS host, a bearer token (new password option
`price_service_token`), wholesale energy only so markup and taxes are added as
for generic_dayahead.

The chain is server, then energy-charts, then the prices the history store
kept. A step counts only if it has a price for now. Each step down and back up
is one log line. With every source down a site plans from what it saved.

No price for now: one status row, one Home plan line and one notification, in
English and Dutch, cleared when a price returns. With this provider the
maintenance charge gate reads the provider's prices and keeps the Home
Assistant rule: the current 15-minute price is at or below today's average.

The token is hidden on the settings page, refused when missing, and taken out
of any error text. Other providers, `off` and the Home Assistant pair take the
road they always took (scripted-day probe against 0ce7d35: one line differs,
the refusal that lists the known providers). See
DECISIONS/PRICE-01-own-price-server.md.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 16:22:24 +02:00
adminandClaude Opus 5.5 fd059126cb MAINT-11 review: test an empty unit at the web layer and the page's own refusal words; drop a stale comment
checks / unit (pull_request) Successful in 38m45s
infra-pin / fresh (pull_request) Successful in 2s
Two reviewer mutations survived the suite: the web layer routing only a
truthy unit (an empty unit then started the bare pick), and the page
showing the server's English instead of its own sentence by code. Both
are now checked. The bare maint_start comment that said a per-battery
unit would ship half a surface is replaced by a pointer to
_maint_unit_action(). No behaviour change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-13 23:06:47 +02:00
glenn schrooyenandClaude 21d8a944bc MAINT-11: start or stop the maintenance cycle per battery
checks / unit (pull_request) Successful in 38m46s
infra-pin / fresh (pull_request) Successful in 1s
maint_start and maint_abort take an optional unit. With two or more batteries
each Batteries card has Start cycle and Stop cycle buttons. One slot per site
stays: a start while a battery cycles is refused and names it (no queue). A
battery that is switched off, an unknown unit, and a stop on a battery that is
not cycling are refused with a plain message. A request with no unit is the
old call. The scheduler and the phase machine are unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-13 21:37:36 +02:00
glenn schrooyenandClaude 065792aad3 Merge release/1.0 (e3e4ba6) into opt15-price-run-fixes
infra-pin / fresh (pull_request) Successful in 3s
checks / unit (pull_request) Successful in 39m30s
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
  clears the chargers, a probing refuser included, while a battery drains
  (SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
  (`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
  its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.

Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
  until the quarter's first sample, as the old edge tick was not, so a
  standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
  off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
  F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
  drain and the day plan against the probe.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-13 12:15:44 +02:00
adminandClaude Opus 5.5 d94cb0c263 SAFETY-112: say plainly that control waits for Home Assistant to start
checks / unit (pull_request) Successful in 36m38s
infra-pin / fresh (pull_request) Successful in 2s
The Supervisor proxy answers 502 to every add-on read, write and websocket
until Core is RUNNING (proxy.py api()/websocket() -> check_api_state()), so
the add-on cannot control while a slow integration holds HA's start, even
with its entities live. Measured on a safety112 repro stack with the
2026.08.0 proxy code: first write 1.0-4.4 s after RUNNING, 238-300 s after
live readings. Not routed around (DECISIONS/SAFETY-112-...).

While the API does not answer, the first status row is red and is the
banner ("Waiting for Home Assistant to finish starting"), Home shows a
"waiting" state in EN/NL instead of "Needs you now", and the log adds a
"still waiting" line every 5 minutes and the wait's length at the end.
A safety stop, a stalled loop or shadow mode keeps its own headline.
Control, writes, heartbeat and the stand-down are unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-13 01:07:51 +02:00
glenn schrooyenandClaude Opus 5.5 9b1fa758ad OPT-17: the solar forecast can come from several entities, summed
checks / unit (pull_request) Successful in 36m13s
infra-pin / fresh (pull_request) Successful in 1s
New list options pv_forecast_entities and pv_forecast_tomorrow_entities
(same shape as pv_entities); the single-entity keys are unchanged.

- Each member is read in its own unit (Wh/kWh/MWh) in one gather and the
  day is summed. Hourly splits are merged when every member has one, else
  the total goes on the bell.
- A member missing, unavailable, stale, non-energy or bad makes that
  day's forecast unusable (no partial sum). A caution row names it by
  position; the action log names the entity once per change.
- Single key and list both set for one day: refused at start.
- A one-member list behaves exactly like the single key (test_opt17.py);
  the single-key path is byte-identical to e36565f over 24 scenarios.
- Supervisor shape measured: tools/supervisor_shape_probe.py section J.

DECISIONS/OPT-17-several-forecast-entities.md has the rules.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-11 02:55:58 +02:00
glenn schrooyenandClaude Opus 5.5 d12228d986 SAFETY-107: a refusal held under another writer is learned once
checks / unit (pull_request) Successful in 35m8s
infra-pin / fresh (pull_request) Successful in 2s
At one inverter SAFETY-52's "another writer" end tested target != loop_w.
A held refusal makes the loop ask 0 W, so any binding claim (maintenance
charge, peak guard, trade) ended it every cycle, and compute() learned it
again in the same cycle: "BATTERY REFUSES" / "ENDED: another writer" each
second on the rig. Now the held refusal is judged afresh against the
writer's ask (compute() gets the same inputs as before); it ends only if
compute() no longer finds it. Commands unchanged: 300-seed differential
trace against release/1.0, N=1 and N=2, every command and refusal state
identical. DECISIONS/SAFETY-107.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-09 03:03:06 +02:00
glenn schrooyenandClaude Opus 5.5 6836f61bd4 MAINT-13 round 3: provider site, hourly fixed-tariff check, faster tests
checks / unit (pull_request) Successful in 34m52s
infra-pin / fresh (pull_request) Successful in 1s
- A price-provider site with no fixed tariff is not a gate (its plan never
  sets `cheap`); DECISIONS §3 says so and a test pins it.
- The fixed-tariff check is worked out once an hour, not every tick.
- test_maint13: run() steps really are `step` minutes; the long loops use
  5-minute steps (the per-tick cap); wall backstop checked "not before".
- test_safety93: the drain bound is the rig's configured drain rate.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 12:03:55 +02:00
glenn schrooyenandClaude Sonnet 5.5 f7b83cc75c MAINT-13 round 2: read the price gate without a new main.py option read
checks / unit (pull_request) Successful in 34m35s
infra-pin / fresh (pull_request) Successful in 1s
test_static_tariff forbids main.py reading `static_profile`; a small
static_gated() in static_tariff.py answers it, and the Controller keeps the
answer in `_price_gated` beside `cheap`.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-08 11:10:33 +02:00
glenn schrooyenandClaude Sonnet 5.5 6f05b2e4be MAINT-13 round 2: gate open when nothing holds the charge back; safety93 scenario restored
checks / unit (pull_request) Failing after 34m45s
infra-pin / fresh (pull_request) Successful in 2s
- gate_open is true with no price gate set up, in a cheap window, or while the
  pack is taking charge; the stall rule and timeout now work on a no-tariff site.
- reset the save timer on a phase change; exact 5 min gap-cap test.
- test_safety93: original timeout scenario kept (B finished) plus a case where a
  due B takes the slot after A's failure.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-08 10:29:46 +02:00
glenn schrooyenandClaude Opus 5.5 28eff568b5 MAINT-13: a full pack that stops at 98-99 % is not a failed charge
checks / unit (pull_request) Successful in 34m21s
infra-pin / fresh (pull_request) Successful in 1s
A charge is complete at SoC >= target, or at >= target - 3 once the SoC has
made no new high for 60 min of allowed charging, or when the charging time
runs out at >= target - 3. The 36 h timeout counts only the minutes the price
gate let the pack charge (plus a 7 day wall-clock backstop). A cycle that
fails (stuck drain, charge below target - 3) backs off 7 days, tells the
operator once (EN + NL), and no cycle starts on that pack in that time unless
the operator forces one. State survives a restart; old state files load.

No option added. DECISIONS/MAINT-13-full-pack-is-complete.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 09:36:06 +02:00