glenn schrooyenandClaude Opus 5 753f700539 DEV-02: merge release/1.0, and close the two review blockers
checks / unit (pull_request) Successful in 4m15s
PR #43 was rejected on two findings and had gone unmergeable behind SAFETY-28
and the ALLOC-01 fix. This is the merge commit; the conflict resolution and both
fixes are below, because a merge that also changes behaviour has to say so.

THE MERGE, AND WHAT IT COST
===========================
Two conflicts in main.py, both where SAFETY-28 and this card touched the same
method:

  * `write_setpoint()` split into a site entry point plus a per-unit
    `_write_unit()` here, while SAFETY-28 put its record gate in the old
    single-unit body. `write_refusal()` now takes the INVERTER it is about.
    Asking it with `self.unit` - as release/1.0 does - would authorise A's share
    on B's wire, and would also trip test_inverter.py part 1's AST scan, which
    goes red on any read of a Controller N=1 view inside Controller.
  * the SAFETY-28 gate sits above the clamp and below the non-finite coercion,
    exactly where release/1.0 put it, and is now asked about `inv`.

Fallout the merge produced in the checks, re-aimed rather than relaxed:

  * every fixture that calls `write_setpoint()` DIRECTLY - the clamp probe, the
    hung-heartbeat experiment and its serialised counterfactual, the split
    deadline probe - now arms a real allocation record first. test_inverter.py
    grows an `arm()` built through the shipped `resolve()`, the same shape
    test_clamp.py's is: the per-unit envelopes are filed as real `supervised`
    claims and the site target is their sum, so the water-fill has exactly one
    answer and the fixture cannot quietly become its own allocator.
  * test_clamp.py's two-unit failsafe fixture assigned `c.units`, which DEV-02
    made a derived property with no setter. It appends a real `Inverter`.

BLOCKER 1 - AC 4's ARBITER-BOUND EVIDENCE WAS VACUOUS
=====================================================
test_peakguard.py claimed "each unit's `supervised` bound is ITS OWN `max_w` -
give inverter B a different rating and the claim filed on inverter B moves with
it", and compared B's bound against `_b2.max_w`. `second_inverter()` DEFAULTED
B's rating to `LIVE_MAX_W`, which is A's. IT COMPARED (-5000, 5000) AGAINST
(-5000, 5000): a number against itself, unable to observe the failure it named.

Reproduced: filing the per-unit `device`/`supervised` claims from
`self.inverters[0]`'s numbers while leaving `actuator=self.actuator_of(..., inv)`
alone left ALL 19 FILES GREEN. At a roster of two with A=5000/B=3000 that makes
inverter B's planned envelope (-5000, 5000) instead of (-3000, 3000) - a 2000 W
over-command the arbiter believes is supervised. It is a DIFFERENT defect from
the actuator variant the static routing pin catches, and only the actuator
variant was in the mutation table.

  * `second_inverter()` gives B 3000 W - a hypothesis, marked as one - for every
    fixture in the file, so no check there can compare B against A by accident.
  * the claim is asserted against LITERAL numbers rather than against an
    expression that can read the same object twice, for `supervised` AND for
    `device` (whose `dev` had the same defect), plus the envelope the ARBITER
    RESOLVED for B - a claim filed right and resolved wrong is the same defect
    one layer down.
  * a PRECONDITION check fails if the two ratings are ever made equal again.
  * the BOUND mutation is in the table, beside the actuator one, and was
    observed RED (3 checks in test_peakguard.py) via tools/mutation_run.sh.

⚠️ THIRD INSTANCE THIS SESSION of a check whose DATA cannot reach the failure it
names - ARB-03's call-site scan saw 3 of 8 appends, ALLOC-01's replay generator
saw 0 escapes where a widened one saw 39,991. MUTATION.md gains a section for it
beside the stale-bytecode and masking ones, and the rule is written at the line:
ANY CHECK ASSERTING "X DIFFERS FROM Y" MUST BE RUN ONCE WITH X AND Y ACTUALLY
MADE DIFFERENT.

BLOCKER 2 - THE LATCH WAS SILENTLY DISARMED BY THE ROLLBACK ROUND TRIP
======================================================================
store.py's rule 2 keeps the flat keys "so a rollback still finds its latch". The
operator path that rule contemplates is a ROUND TRIP, and this card lost the
latch on it:

  1. install migrates          -> schema_version=1, unit/inverter-a/... = False
  2. operator DOWNGRADES; SAFETY-02 trips inside the downgrade window and the
     old add-on writes only the flat `sign_tripped: true`
  3. operator upgrades again   -> `rep.ran` is False, so `_grade_store_migration()`
     returned early, and `Inverter.__init__` read the namespaced key: False

Observed: the controller came up with `sign_wd.tripped = False` while
/data/state.json said `sign_tripped: true`. That is store.py's own header
sentence - "the file still says sign_tripped: true, the banner is green, and the
controller resumes driving the wrong way" - rebuilt by the version marker. A
firmware version change with a rollback path was performed on this site on
2026-09-02, so this is not hypothetical.

Three changes, each graded by a mutation observed RED:

  * THE OPERATOR'S CLEAR CLEARS BOTH SPELLINGS. That is what removes the
    "re-arm forever" objection the `rep.ran` gate existed to answer: with the
    fossil cleared, `flat True + namespaced False` is unambiguously a
    downgrade-window latch.
  * A TRIP MIRRORS THE FLAT PAIR. Rule 2 only ever covered the latch present AT
    MIGRATION TIME - nothing flat was written for a trip taken afterwards, so an
    operator who downgraded found `sign_tripped: false` and came up DRIVING.
    store.py claimed the staleness could only fail toward a SPURIOUS latch. It
    could not; that sentence is corrected rather than left standing.
  * THE GUARD RUNS ON EVERY START, and asks the STORE - not the roster - whether
    anything namespaced is latched. A mirrored trip on B must not re-arm a
    healthy A, and the store is the right place to ask because it holds every
    `unit/*/sign_tripped` this install has written, including one belonging to a
    unit that is not in today's roster.

Graded by the three-step scenario itself, run end to end in test_inverter.py
part 2, with all three preconditions asserted - including that the catching
start did NOT migrate anything, which is what used to skip the guard. Part 2's
idempotence check now PRESSES the button instead of hand-writing the store,
because the state it used to construct is not one the shipped clear path can
produce. Part 3 grades the mirror and the clear on a real roster of two.

test_watchdog.py's "the flat key is NOT written" assertion is re-aimed rather
than deleted: its argument was right about the READ and wrong about the WRITE.
Nothing at runtime reads that key, and the one thing that does ignores it
whenever any namespaced latch is set - which a sibling's trip always leaves.
What its absence actually cost was the rollback.

HANDOVER.md and DOCS.md said the flat key "is never read again", which was the
instruction an operator clearing a trip by hand would follow. Both corrected: it
is a maintained rollback view, it IS read on every start, and clearing a trip by
hand means clearing both spellings.

MUTATIONS THIS ROUND, each applied on a purged tree via tools/mutation_run.sh
and observed RED:
  * per-unit `device`/`supervised` BOUNDS from `self.inverters[0]`, actuator
    left correct                                   -> test_peakguard.py 10g
  * `_grade_store_migration()` gated on `rep.ran`   -> test_inverter.py part 2
  * the operator's clear leaving the flat keys set  -> test_inverter.py part 2/3
  * a trip not mirroring the flat pair              -> test_inverter.py part 3
  * the guard asking only `self.inverters[0]`       -> test_inverter.py part 3

19/19 files green on the merged tree. No hardware was touched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-03 23:37:23 +02:00
glenn schrooyenandClaude Opus 5 e306c74cb8 DEV-02: per-instance inverter objects, so nothing is graded against a sibling
checks / unit (pull_request) Successful in 4m15s
Every piece of per-device state in the Controller was a scalar, and several of
them are safety inputs. app/inverter.py introduces an `Inverter` that owns its
entities, its rating, its device range, its SignWatchdog, its last_write and
its last_beat, under store keys namespaced by unit name. The Controller holds a
list of them and keeps only what is genuinely site-level: the P1 reading, the
site integrator, and the tariff quarter.

WHAT THE SCALARS WERE SILENTLY ASSERTING

  dev_min/dev_max   one pair, read from one setpoint_entity. A second
                    inverter's rating was NEVER READ AT ALL, so its clamp, its
                    freeze rail and the peak guard's achievable_w were the
                    first one's numbers.
  soc               one reading into the maintenance FSM, SAFETY-24's pack
                    floor and arbitrage's bounds. An average lets the emptier
                    pack be driven below its own floor.
  sign_wd           ONE SignWatchdog, whose own docstring says "one instance
                    per actuator", latched under FLAT store keys - so a trip
                    caused by B latched A across restarts and one operator
                    press cleared both.
  last_beat         one deadline and one serialised hass.call(), so a hung
                    write to A ate B's 30 s layer-1 budget.

actual_w BECAME SITE LEVEL WHILE THE READINGS BECAME PER-INSTANCE, and those
are opposite directions on purpose. compute()'s anti-windup test is
`abs(prev_w - actual_w) > saturation_w` with prev_w the SITE target, so feeding
it one inverter's power compares a site number against a unit number, trips the
saturation freeze permanently and leaves a standing grid error. Measured on
admin/goodwe's two-master rig (tools/alloc_sim.py --splits, 2 kW load, 40
cycles), worst |delta| between splits at the meter:

    gain    one unit's power      the site sum
    0.2           510 W                0 W
    0.4           250 W                0 W
    0.6            50 W                0 W

That was ALLOC-01's disclosed finding; test_alloc.py part 8 kept its stimulus
and now grades the other row.

THE STORE MIGRATION IS GRADED, NOT MERELY PERFORMED. sign_tripped/sign_reason
move to unit/<name>/... once, verified by READING BACK what was written, and
the version marker is set only when nothing that carried state was lost. The
flat keys stay in the file so a rollback still finds its latch. And __init__
compares the pre-migration flat latch against what unit A actually came up
with: if the latch did not survive it is RE-ARMED from the legacy value and
shouted about. A latch that silently fails to migrate is a disarmed safety
guard on an install whose state file says it is protected - which is strictly
worse than never persisting it, because now there is evidence saying it is
fine. test_inverter.py part 2 breaks the migration and watches the guard fire.

HEARTBEATS ARE INDEPENDENT AND THE BUDGET IS DERIVED. Each inverter owns its
deadline, the refreshes go out concurrently, and each write is bounded by
WRITE_BUDGET_S = 4 s. The inequality is graded rather than asserted: 4 +
heartbeat_s's schema maximum of 25 < 30, validate.FIRMWARE_INGEST_VETO_S.
Verified by injecting a transport that accepts and never answers.

live_units() ANSWERS HONESTLY. A unit whose every write has been rejected for a
whole layer-1 window is not commandable; the allocator drops it, the survivors
carry its share, the action log names it, and the dropped unit is commanded
0 W rather than left standing on its last share. A roster entry with NO
setpoint_entity is deliberately not handled there - that is a configuration
that cannot be delivered, and it reaches main.py's refusal branch, which is how
that branch keeps a live trigger after this card removed its old one.

AT N=1 NOTHING MOVES. The removed scalars survive as read/write properties of
the sole inverter, so every existing replay runs unmodified - and they REFUSE
at N>=2 rather than answering for the first inverter, which is the tripwire on
a consumer that was never made per-instance.

EVIDENCE. 19 files green. test_inverter.py is new (82 checks). Eighteen
mutations were applied to the shipped modules on a purged tree via
tools/mutation_run.sh and each was observed RED. Two of them SURVIVED first
time and the checks were changed rather than the table: the serialised dispatch
and the shared last_beat both passed while part 6 gathered its own writes and
computed its own `due` list. send_heartbeats() was extracted from run_control()
so the shipped dispatch is reachable by a check at all.

INVERTER B STILL DOES NOT EXIST. build_roster() returns exactly one inverter
from the flat options and is the one function CFG-04 changes; every two-unit
figure here is architecture, and the second rating in the checks is marked a
hypothesis.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-02 14:50:43 +02:00
glenn schrooyenandClaude Opus 5 cc4e88490b SAFETY-02 review: a latch that a restart clears is not a latch
BLOCKER. `auto` was persisted and `sign_wd.tripped` was not, so reconstructing
the Controller against the same store - which is what a container restart does -
brought it back ARMED, into the same fault, unattended: tripped=False, banner
back to NOT READY, and it resumed commanding -1000 then -2000 W before
re-tripping 180 s later. "Restart the add-on" is the first thing an operator
looking at a FAILSAFE banner and a 0 W inverter will try, and under a supervisor
that restarts a crashed add-on it is a loop of three-minute wrong-direction
bursts. DOCS.md's "it does not clear itself" was false across a restart.

`sign_tripped` and `sign_reason` are Store keys now, beside the maintenance
state and for the reason store.py's own docstring gives. Written the moment the
trip happens - reason first, flag second, so a crash between the two can never
persist a latch with no explanation - restored in Controller.__init__, cleared
only by the operator's start. The regression is covered: reverting the restore
fails seven checks in test_watchdog.py.

Review follow-ups, no behaviour change:

- The arming gate is tested against the REAL arbiter. It is the decision the
  ticket turns on and it was asserted in three comment blocks and verified by
  nothing - every case passed `following` in as a literal. Twelve claim
  configurations now derive it from resolve(), including the redirect case
  `winner == "loop"` alone would have got wrong and the `lo` limit that raises
  magnitude without flipping sign.
- The MQTT `status: "failsafe"` value is tested. The check that claimed to cover
  it restated the line above it and never touched the payload.
- The worked example described a config that does not ship: at the defaults
  maintenance_charge_w 2500 against max_w 2000 is an arbiter contradiction and
  0 W, not a -2500 W charge. Rewritten at 1500 W. The contradiction is a real
  pre-existing bug - a default cheap-window maintenance charge silently never
  happens - filed separately and deliberately not fixed here.
- Forward hazard recorded at the gate: `winner == "loop"` disarms the watchdog
  under any higher-priority SET, and a peak-shaving strategy at P_PEAK IS
  grid-following in sign, so it would blind this for every peak event.
- disagrees() is public so the replay harness stops carrying its own copy of the
  predicate it grades.
- held_s takes the clock instead of reading one.
- The two limits are now each stated in both places rather than one each.
- The no-false-positive argument is tied to control.py's freeze permitting the
  command to cross zero; under the shrink-only encoding control.py records as
  rejected, this would false-trip on a load step.
- Measured figures corrected: 93.4 % / 4212 of 17280, per-cluster
  0.3/0.9/10.5/0.0, and the near-circularity of those figures is now stated
  rather than leaned on.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 22:33:15 +02:00
adminandClaude Opus 5 594f8f9fc9 Six silent failures found by installing this on a live system
Migrated the reference site off the YAML packages and onto the add-on. Every
bug below presented identically: the add-on starts, logs "started", serves its
UI, and cannot do its job.

- run.sh needs #!/usr/bin/with-contenv sh. s6-overlay sanitises the environment
  for services, so a plain shebang means SUPERVISOR_TOKEN is absent and every
  Core API call is 401 - while homeassistant_api: true makes permissions look
  granted. Startup now prints the token length and probes the API.
- Supervisor keys the image by config.yaml `version`, so rebuilding without a
  bump reuses the old image. Two fixes appeared not to work because of it.
- Alpine is musl and has no aiohttp wheel on PyPI; deps now come from apk so
  nothing compiles on a client's Pi.
- Alpine ships paho-mqtt 1.x, which has no CallbackAPIVersion. That raised at
  construction and took the control loop down with it - so MQTT setup is now
  wrapped too. Observability must never be able to stop the controller.
- MQTT discovery is published from on_connect: paho silently drops QoS-0
  publishes issued before the CONNACK, so the previous code announced nothing
  while logging "MQTT connected".
- Repeated failures now log once a minute. Six warnings a second rolled the log
  buffer and destroyed the startup diagnostics needed to find the 401.
- auto_start could never fire, because the store's defaults always supplied
  auto: False for the fallback to find.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 02:25:58 +02:00
adminandClaude Opus 5 0a1e61dbc9 Packaged as a Home Assistant add-on, with a field guide
Turns the reference RS485 controller into something a technician can install
at a client site: a typed config form instead of YAML, an ingress UI that
names misconfiguration in words, and persistent state that cannot be broken by
a timezone.

Why an add-on rather than YAML packages or blueprints:

- Blueprints cannot create helpers, and the maintenance cycle is a state
  machine whose phase and completion date must survive restarts.
- YAML packages need filesystem access, a configuration.yaml edit and a
  restart - none of which belong in a client install.
- Add-ons authenticate with SUPERVISOR_TOKEN, so there is no long-lived token
  to generate, store or leak on someone else's machine.
- Requires HA OS/Supervised. Container and Core installs cannot run add-ons at
  all, which is a market decision, not an oversight.

The control law and the maintenance machine are pure functions with no Home
Assistant imports, and both ship with runnable checks (22 and 22 assertions).
Every assertion corresponds to a rule whose absence caused an observed failure
on hardware - the saturation duration term, the clamp-before-slew ordering, the
deadband, the sign convention.

One behaviour deliberately differs from the implementation it replaces: when
its inputs go missing this commands 0 W rather than replaying the last
setpoint. The reference version kept replaying, which the hardware watchdog
cannot catch - from the ESP32's side, Home Assistant is still talking to it.

Includes the ESPHome firmware (now parameterised: node name, inverter rating,
watchdog timeout) and the optional RS485 e-stop. FIELD-GUIDE.md carries the
commissioning gates, all judged on the wire rather than on how Home Assistant
looks, plus the written statement a site without an e-stop needs signed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>