ems-agentandClaude 69f58181bc EV-05 round 5: headroom counts only the batteries that can give
checks / unit (pull_request) Successful in 24m24s
infra-pin / fresh (pull_request) Successful in 2s
Review of 8818768: the headroom test compared the output with the site
rating, which still counted a battery refusing to give (SAFETY-73) or under
a safety stop, so the 15 s wait ran at the real maximum (N4). Now only the
units that can give (above their cut-out, not refusing, not stopped,
switched on) count, in what they give and in their ratings.

Tests: R5a (A refuses, B at full rating, against a car-Off twin: the cut at
910, period 3361 W), R5b (headroom and a slow battery: the cut at exactly
15 s), R5c (floor-limited alone decides: cut at once). DOCS wrapped to 79.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 17:27:17 +01:00
ems-agentandClaude 8818768dab EV-05 round 4: the cut waits only while the batteries have headroom
checks / unit (pull_request) Successful in 23m43s
infra-pin / fresh (pull_request) Successful in 1s
Review of d2504ef, brief v5 Expected 8 (owner 2026-11-18): the 15 s wait
needs batteries that can still raise their output: above the cut-out, the
guard neither saturated nor floor-limited, and their output more than 100 W
under what they can give. Otherwise the car is cut at once.

Tests: R4/N4 rows against a car-Off twin (house to 25900 and 25950 W, aim
3400 W) land under the aim; T21/T22 cut at once beyond the batteries; the
T21b catch rows and T44 (0 cut pauses) stay green.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 16:02:01 +01:00
ems-agentandClaude d2504efa82 EV-05 round 3: a refused way-out 0 A is tried again; one cut per excess
checks / unit (pull_request) Successful in 24m5s
infra-pin / fresh (pull_request) Successful in 2s
Review of 17a7b29:
- Critical: every way out of Solar (Off, Stop, shadow, safety stop, charger
  error, stuck reading, no car) now owes a 0 A until the charger takes it:
  tried again 60 s apart, 3 times (EV-04's rule), then the gave-up row and
  CHARGER_REFUSED; never over another writer. Shutdown does not trust last_a
  while a write of ours is unconfirmed. The card no longer says paused while
  the 0 A is not taken.
- Major: an excess episode is taken off the car once, measured from the car's
  power when it began, until the car shows it and 15 s more.

Tests: refused-then-accepted 0 A for each exit, a 0 A never taken, shutdown
during a start write's read-back, a cut from 16 A with a slow car; the fuzz
checks refused exits of every kind (N9).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 12:15:00 +01:00
ems-agentandClaude 17a7b299d2 EV-05 round 2: the peak cut waits 15 s while a battery can give
checks / unit (pull_request) Successful in 23m32s
infra-pin / fresh (pull_request) Successful in 1s
Owner 2026-11-18 (dev finding 1, brief v4 Expected 8): while a battery is
above its cut-out, the car's peak cut waits until the guard has wanted power
for 15 s in a row (CUT_WAIT_S), so a cloud edge the batteries catch does not
pause the car. It cuts at once with no battery able, or with 120 s or less of
the 15-minute period left (CUT_NEAR_END_S: waiting 15 s then costs at most
8/7 of the cut, taken off the car at once).

Tests: T21/T22 cut at 15 s and not sooner, the period lands under the aim;
T21b a house step and a cloud edge the batteries catch: no cut, no pause;
T24 (c) late in the period: the cut at once, under the aim; T12's cut row
with the batteries at their cut-out. The harness's battery level model was
1000x too fast (round 1); fixed. The 10-hour day: 0 cut pauses in both
priorities.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 10:13:02 +01:00
ems-agentandClaude 29480fda47 EV-05: car Solar mode (spare sun to the car, Batteries or Car first, cut first for the peak)
checks / unit (pull_request) Failing after 24m58s
infra-pin / fresh (pull_request) Successful in 1s
Solar charges the car from the signed spare sun (car + battery charge - grid
import), less the batteries' room (Batteries first) and the sun kept back,
whole amps rounded down, at most one change per 30 s and only on 1 A. It
starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A.
Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min
down, one switch per 10 min). What the peak guard would ask the batteries for
is taken off the car first, at once. Every way out of Solar ends at 0 A,
written once; at shutdown before the inverters go to 0 W.

- app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write
  site, its sequence and watch); spare_w, car_target_w, amps_for.
- app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for
  Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order.
- Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh,
  three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG.
- test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks
  that pinned "Solar is refused" / "three entities" updated.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 23:54:06 +01:00
glenn schrooyenandClaude 6d7046fc45 EV-15 round 2: the grace opens when the 0 A write is sent
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
The writer runs beside the cycle and the car can stop before the write
returns, so no sequence existed yet and the latch set. Window now opens at
send (zero_sent_at), cleared on return; ends on another writer in the tail too.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 15:24:30 +01:00
glenn schrooyenandClaude 2cfbc4aec8 EV-15: the add-on's own phase change at the peak reserve raises no false alarm
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:26:56 +01:00
glenn schrooyenandClaude b12776c705 EV-10b: grade the alarm on the house alone without the 0 W clip
checks / unit (pull_request) Successful in 22m5s
infra-pin / fresh (pull_request) Successful in 2s
The period without the car was clipped at 0 W, so batteries covering the car
were charged to the house and the floor alarm fired (rig F-1). New
car_exclude_alarm keeps the sign of the rest of the period; car_exclude (the
cover-off guard input) is unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 22:16:29 +01:00
Claude 269b89d6b0 EV-10 round 3: grade the floor case on the same landing with and without the car; per-quarter latches independent of the cover option; stricter write-mute test
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 19:28:02 +01:00
Claude 646f61e730 EV-10 round 2: judge the car against the alarm's own landing; test failed writes; honest hold wording
checks / unit (pull_request) Successful in 22m4s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 18:07:25 +01:00
Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
glenn schrooyenandClaude f31dcb62b6 EV-04 round 3: undo restores the current in shadow mode too, energy rule catches a frozen 6 A figure, settle after a refused select
checks / unit (pull_request) Failing after 21m10s
infra-pin / fresh (pull_request) Successful in 1s
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 07:59:15 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
glenn schrooyenandClaude de06a2c6f5 MAINT-28 fix round 5: while the pause holds, the batteries give only what the guard needs
checks / unit (pull_request) Failing after 38m55s
infra-pin / fresh (pull_request) Successful in 1s
H-1: one site limit while the pause holds (the period's largest floor, never under this cycle's), so the other pack no longer gives for the house. New live-try test (A 11 %, B 25 %, 90 min at 6.5 kW) red on 07d23d2. M-1: a 45-min rig-shape test that goes red when the settled check is forced True. M-2/L-2: DECISIONS. CHANGELOG line. test_safety84 n2_charge_banked re-pinned (quarters 3349 and 3950 W, aim 3950 W).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:40:54 +01:00
glenn schrooyenandClaude 9a76f1a968 MAINT-28 fix-forward rounds 1-4, re-applied after the release/1.0 merge
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude 0020756aab Revert "Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)""
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 16:07:12 +01:00
glenn schrooyenandClaude 7bc8ad264b Revert "MAINT-28: during a real peak the maintenance charge stays paused (#247)"
checks / unit (pull_request) Successful in 27m32s
infra-pin / fresh (pull_request) Successful in 2s
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-14 01:33:24 +01:00
glenn schrooyenandClaude e7706150e8 MAINT-28: DECISIONS gives the measured reason for the uncapped give (review M-1); ctl_cycle comment one line + pointer (L-1)
checks / unit (pull_request) Successful in 27m38s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 05:53:55 +01:00
glenn schrooyenandClaude 29a8a05f30 MAINT-28: shorter test_maint28 runs (892 s -> ~280 s), digests re-pinned on 1b5f7c9; hold kept through the two short holds (documented); DECISIONS duplicate removed
checks / unit (pull_request) Successful in 40m7s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 02:29:27 +01:00
glenn schrooyenandClaude bc5be4964e MAINT-28: N=1 digest test with a banked peak (so the N=1 gate is tested)
checks / unit (pull_request) Successful in 34m0s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-13 00:20:21 +01:00
glenn schrooyenandClaude edf30f345a MAINT-28: keep the single shaping_suspended(.., maint_aim) call site (test_peak_margin pin); shaping_held takes its answer
checks / unit (pull_request) Successful in 32m46s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:58:19 +01:00
glenn schrooyenandClaude 8640bfcbc1 MAINT-28: hold only where MAINT-24 moved the aim (banked peak above the cap); test_safety119 pins stay
checks / unit (pull_request) Failing after 34m27s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 23:13:57 +01:00
glenn schrooyenandClaude 92f0387415 MAINT-28: reset the hold every cycle, test it; digests vs 1b5f7c9; DECISIONS numbers and mutants
checks / unit (pull_request) Failing after 36m49s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:44:32 +01:00
glenn schrooyenandClaude 4f9aa5223f MAINT-28: the hold is for N=2 and up (SAFETY-87 N=1 pins), N=1 peak digest test
checks / unit (pull_request) Failing after 36m51s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 22:28:01 +01:00
glenn schrooyenandClaude 8cd10ee6aa MAINT-28: during a real peak the maintenance charge stays paused until the house is clear of the aim
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m11s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 21:51:56 +01:00
glenn schrooyenandClaude 33cfc733d3 MAINT-25: clean test_maint25.py, split its DECISIONS note
checks / unit (pull_request) Successful in 26m39s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 11:08:30 +01:00
glenn schrooyenandClaude de0790e62d MAINT-25: the Home plan shows no cycle during the 7-day back-off
checks / unit (pull_request) Successful in 27m21s
infra-pin / fresh (pull_request) Successful in 1s
homeview.maintenance_runs() ignored backoff_until(); it drew a cycle every
night of the wait. Now no run and a plain line (EN, NL). test_maint25.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 09:57:56 +01:00
glenn schrooyenandClaude 0f5e513f1d MAINT-24: keep the refusal probe beside a maintenance charge
checks / unit (pull_request) Failing after 45m44s
infra-pin / fresh (pull_request) Successful in 2s
The mode trade still lets a SAFETY-73 probe (PROBE_W alone) go on while a pack
is in its maintenance CHARGE phase; test_opt20.py g7 pins it. ch_ch_maint
digest moved (B no longer grid-charges beside A's charge).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:33:04 +01:00
glenn schrooyenandClaude 54a738dd87 MAINT-24: a started maintenance charge gets the cheap night
checks / unit (pull_request) Failing after 41m45s
infra-pin / fresh (pull_request) Successful in 2s
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-12 07:07:44 +01:00
glenn schrooyenandClaude Opus 5.5 4066624cce SAFETY-135 round 2: the first guard stop in a period may restart once; tests and docs
checks / unit (pull_request) Successful in 29m42s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-11 19:49:18 +01:00
glenn schrooyenandClaude 66d8777b39 SAFETY-135: a young 15-minute period does not cost the night charge the whole period
checks / unit (pull_request) Successful in 41m54s
infra-pin / fresh (pull_request) Successful in 2s
With battery modes on, a grid charge the peak guard (or a measured headroom)
stops in the first 60 s of a period no longer latches off for the period: it
may start again once the period is 60 s old, if the guard is clear and the
headroom is over START_W. A stop after 60 s latches as before. In a young
period no charge starts while the batteries' give is still falling (over
START_W within 15 s), since the meter may not show that drop yet. The guard
itself is unchanged, so a real over-aim load is cut on the same cycle.

DECISIONS/SAFETY-135-young-period.md, test_safety135.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-10 17:43:28 +01:00
goodwe-agent 0f9c119bcf SAFETY-136 round 2: tests for override and direction, true wording
checks / unit (pull_request) Successful in 26m2s
infra-pin / fresh (pull_request) Successful in 2s
F1 the on-change case is tested as slow, F2 override and direction checks,
F3 the 3.75 s rule in the texts, F4 the quarter figures and the live note.
No behaviour change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 20:51:06 +01:00
goodwe-agent c50e2279dd SAFETY-136: a gentler loop on a slow meter until the last move shows
checks / unit (pull_request) Successful in 26m18s
infra-pin / fresh (pull_request) Successful in 2s
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 14:49:26 +01:00
glenn schrooyenandClaude 58b6fa35f5 MAINT-21 round 2: keep the move pure - revert the added DECISIONS text, restore cut comments
checks / unit (pull_request) Successful in 26m32s
infra-pin / fresh (pull_request) Successful in 1s
Router T241: the comments commit had put new rationale into
MAIN-orchestration.md and cut comment lines that the note at 56fc41f did not
hold.

- DECISIONS/MAIN-orchestration.md is the 56fc41f text plus the one sentence
  that the Controller is split into app/main.py and app/ctl_*.py.
- Comments whose content is not in a DECISIONS note at 56fc41f are back in the
  code verbatim: MAINT-05 one config, the SAFETY-02, SAFETY-42/34,
  SAFETY-30 site half, SAFETY-31 and SAFETY-18 latch blocks in __init__, the
  _grade_store_migration docstring and comment, the trade_power_w docstring,
  the rows.py docstrings.
- Kept: cuts of text already in the note, the SMA-10 / SAFETY-137 / SMA-2
  pointers, the SAFETY-32 line fix.

No code change: maint21_same_ast OK, maint20_same_code -OO same.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 05:48:00 +01:00
glenn schrooyenandClaude 902da3f723 MAINT-21: comments only - trim restated notes, add DECISIONS pointers
checks / unit (pull_request) Successful in 25m17s
infra-pin / fresh (pull_request) Successful in 1s
No code change: tools/maint21_same_ast.py and tools/maint20_same_code.py HEAD~
both print OK, and the -OO code objects are the same.

- Trims 56 comment and docstring lines (2088 -> 2032) in app/main.py and the
  new files that only restated their MAIN-orchestration.md bullet, each cut to
  its first sentence and a pointer. What the cut comments said and the bullet
  did not is now in the bullet: why a SAFETY-02 latch is restored, why the
  SAFETY-30 site check is not armed at one inverter, the SAFETY-18 re-derive,
  the MAINT-05 one-config rule, the OPT-09 sizing rules, the "no plan" row,
  the 5 400 s age bound, and the guard being the only latch repair.
- Adds the missing DECISIONS pointers on the SMA-10, SAFETY-137 and SMA-2
  comments (FALLBACK_BUDGET_S, write_setpoint, _await_inflight,
  _release_last, the retry wait, the failed-release branch, release_zero_sent,
  the in-flight write, the stop_event hand-back, the SMA-2 read and driver).
- DECISIONS/SAFETY-32: the stale `main.py:932-936` now names
  Controller.pack_floor_soc.
- main.py's docstring and import block say where the Controller's parts are.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:41:34 +01:00
glenn schrooyenandClaude Opus 5.5 bbbc89b235 MAINT-20 part 2 review: comment-only fixes in main.py and the MAIN notes
checks / unit (pull_request) Successful in 30m13s
infra-pin / fresh (pull_request) Successful in 1s
- check_peak_floor_limited: restore the SAFETY-25 line (the reserve sentence is
  in messages.peak_reserve() on every branch, unreadable SoC included).
- Three status-page comments that no longer said anything (SAFETY-20 row,
  AC 5 delivery row, banner-vs-text) now say their rule in one line.
- tariff_refresh_wanted docstring: no orphan "TARIFF-24)" line.
- MAIN-orchestration.md: blank line before the first heading.
- MAIN-orchestration-archive.md: refilled intro; says how to find a section
  from a main.py pointer.

No code change: maint20_same_code.py 16029d7 -> SAME CODE, -OO same.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-08 19:25:37 +01:00
glenn schrooyenandClaude f8df7cd860 MAINT-20 part 2 r2: DECISIONS MAIN-orchestration-archive intro
checks / unit (pull_request) Successful in 25m14s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-08 18:06:01 +01:00
glenn schrooyenandClaude 8fc5f15b03 MAINT-20 part 2 r2: cut the comments that came in with SMA-2, SMA-10, SAFETY-128 and SAFETY-137
Word for word in MAIN-orchestration-archive.md, keyed by the line at 16029d7.
No code change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-08 17:29:27 +01:00
glenn schrooyenandClaude c2b4302dcf Merge release/1.0 (16029d7) into MAINT-20-2
Nine conflicts in app/main.py, all in comments around new code: every code
line is release/1.0's, every comment follows the part 2 rule.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-08 17:28:03 +01:00
Claude 8953be0362 SAFETY-137: the shutdown and Stop 0 W is the last write every unit hears
checks / unit (pull_request) Successful in 22m59s
infra-pin / fresh (pull_request) Successful in 1s
The 0 W of shutdown and of the Stop button now waits (bounded, 2 s) for a
write already on its way to the same unit, for every driver, GoodWe included.
Once shutdown has begun, cycle, heartbeat and safety-stop writes are dropped
right before the write is created. One shared wait (_await_inflight) serves
the 0 W and SMA-10's _release_last.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-08 02:39:38 +01:00
glenn schrooyenandClaude 6cae5a2f8f SMA-10 round 4: pin the Dutch default "de eigen sturing"
checks / unit (pull_request) Successful in 30m41s
infra-pin / fresh (pull_request) Successful in 2s
The NL default for a hand-back driver without words (handback._BACK_NL) was
changed to "de eigen sturing" in round 2 at the PR #239 review's request
(comment 2495: the article as in the generic clause). The brief does not name
it, so DECISIONS now says where it came from and a test checks the exact Dutch
sentence. No app code change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 22:45:08 +01:00
glenn schrooyenandClaude d26cc573fe SMA-10 round 2: a failed release sends 0 W once, retries at heartbeat pace
checks / unit (pull_request) Successful in 23m37s
infra-pin / fresh (pull_request) Successful in 2s
When release() fails (False, raises or hangs past RELEASE_BUDGET_S) the unit
gets one bounded write(0) through the new Driver.release_fallback() hook
(default write(0)), then nothing more, so the inverter's own fallback timer is
not reset. The release is retried once per heartbeat, not on every idle
write. One error line and one action-log event per failure streak, one line on
recovery. Dutch default "terug naar de eigen sturing". DECISIONS says what a
unit is left at.

test_messages.py: the RELEASE_BUDGET_S data entry is gone again (the line
that needed it is gone).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 20:17:01 +01:00
glenn schrooyenandClaude a1be9c48b3 SMA-10: two idle states, hold 0 W or hand the inverter back
checks / unit (pull_request) Successful in 24m9s
infra-pin / fresh (pull_request) Successful in 1s
A driver now says whether its release() hands the inverter back
(Driver.hands_back; GoodWe is False, so release() stays write(0) and the
Controller never calls it). command_site_release() sits next to
command_site_zero(): the Stop button and shutdown() (so SIGTERM, restart,
control task death and a late config refusal) hand a hand-back unit back,
once, and zero every other unit as before. Safety stops and refusals still
hold 0 W for every unit. Shadow mode releases a hand-back unit. After a
release nothing is written to the unit (heartbeat and cycle included) until
control starts again. release() is bounded by RELEASE_BUDGET_S (= the write
budget), runs concurrently per unit, and a raising or hanging release on one
unit does not stop the others.

The "set to 0 W" sentences for Stop, restart, shadow mode and the stopped
banner are built from the roster (app/handback.py, EN and NL, words from the
driver); a GoodWe-only roster keeps every old literal. A handed-back unit
shows "Back under <its control>" on Home.

Existing test edited: test_messages.py (two classification entries for the
CRITICAL line that moved into a roster builder, and the new release bound).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 18:21:28 +01:00
glenn schrooyenandClaude c015230452 SMA-2 round 2: keep the driver keys out of the schema, translations and labels
checks / unit (pull_request) Successful in 23m13s
infra-pin / fresh (pull_request) Successful in 1s
Owner decision 2026-11-07: clients see nothing new until SMA-4. config.yaml,
translations, labels and the page layout are back to 23ff9d0's. The validation
of the keys stays for callers that skip the schema.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 13:09:31 +01:00
glenn schrooyenandClaude 0b20f53cf8 SMA-2 round 2: census keeps ACTUATOR_WRITE_KEYS, setters, NaN/inf port refused, tests
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 12:20:56 +01:00
glenn schrooyenandClaude e56eeef8f0 SMA-2: each inverter is reached through a driver; GoodWe behaviour unchanged
checks / unit (pull_request) Successful in 23m14s
infra-pin / fresh (pull_request) Successful in 2s
app/drivers.py holds one Driver per roster entry (configured, actuator_id,
limits, read, write, release, probe, link_stale_s, batt_bound, settle_s, brand,
words). GoodWeEsphomeDriver makes the calls the code it replaced made, in the
same order. Inverter gets driver; has_writer, is_live and link_note read it. The
SoC/power read, the write, the device range (run_control, amain, the settings
panel), rule 2 per unit and the SAFETY-28 census go through it.

setpoint_entity is optional per entry beside driver, host, port, unit_id and
maintenance; only goodwe_esphome is selectable, the rest are checked and unused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 11:28:47 +01:00
glenn schrooyenandClaude c43873b142 OPT-38: a kept tomorrow forecast reading stands in at any hour
checks / unit (pull_request) Successful in 22m54s
infra-pin / fresh (pull_request) Successful in 1s
One stale Forecast.Solar tomorrow sensor dropped the whole OPT-17 sum from
17:54 to 20:00. Today readings and the OPT-34 morning rules are unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 04:24:01 +01:00
glenn schrooyenandClaude c70eeb6916 SAFETY-129 round 3: the real reason for the 16 s limit, a slow-start check, the row's tail
checks / unit (pull_request) Successful in 23m1s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-07 00:12:33 +01:00
glenn schrooyenandClaude 85433edac6 SAFETY-129 round 2: shorter test_safety129, pinned 5 s row, 100 s bound
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-06 21:24:37 +01:00