Commit Graph
904 Commits
Author SHA1 Message Date
Claude 5ebd830966 EV-13 review: compare phase currents per phase; test a late read-back
checks / unit (pull_request) Successful in 26m23s
infra-pin / fresh (pull_request) Successful in 1s
A phase that drops out or comes back shifted the compressed current_a tuple and
read as life, so a frozen charger never armed. ChargerReading.phase_a keeps
L1/L2/L3 with None for a missing phase and the life test uses it.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 05:44:31 +01:00
Claude 1b39f1698a EV-13 router round 1: lapse a refusal's window on unavailable readings; T27, T28 and the N-ids
checks / unit (pull_request) Successful in 31m40s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 03:56:53 +01:00
Claude c3903b796b EV-13: CHANGELOG line and DECISIONS note
checks / unit (pull_request) Successful in 33m25s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 02:23:56 +01:00
Claude c25877fea4 EV-13: a refused current write arms the stuck check only when the charger shows no life
A refused write on a live charger no longer reads as a stuck reading 60 s
later, so a refused write shows one amber row (charger_refused). A frozen
charger still arms and is still caught.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 01:50:44 +01:00
ems-agent 76f4de23c7 Merge pull request 'EV-28: no phase select while the car still draws' (#268) from EV-28 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-21 23:28:03 +01:00
Claude (review agent) 4b4a4c1053 EV-28 review: pin the restore step in T17a and the counted failure in T15
checks / unit (pull_request) Successful in 28m34s
infra-pin / fresh (pull_request) Successful in 1s
Review fixes, no logic change:
- T17a now asserts the restore is the first write once the charger is back
  (it was only checked to happen at some point); mutant M3 (restore after
  SETTLE_S) now turns T17a red.
- T15 now asserts the refused restore is counted once (`fails == 1`);
  a mutant without `_failed` there now turns T15 red.
- DECISIONS "The phase sequence" and the carmode docstring reflowed to 79
  columns; DECISIONS says D counts as drawing too, as the code does.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-21 22:58:56 +01:00
Claude (dev agent) 83f114fe08 EV-28: never select the phases while the car still draws
checks / unit (pull_request) Successful in 32m4s
infra-pin / fresh (pull_request) Successful in 1s
Stage zero counted mode3 B as quiet whatever the power and selected at the
20 s timeout under load. A power reading now decides (under 100 W); mode3
(not C, not D) only without one. Still drawing at 20 s: no select, the
current comes back at once, one failed try, next try PHASE_GAP_S later.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-21 21:04:13 +01:00
ems-agent 4eba2d9acf Merge pull request 'CI-20: bump infra-pin to f884612' (#267) from CI-20 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-21 19:37:59 +01:00
Claude af374026b1 CI-20: bump infra-pin to admin/goodwe release/1.0 f884612
checks / unit (pull_request) Successful in 26m51s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-21 18:33:08 +01:00
admin 00b116e5b2 Merge pull request 'EV-16: hold the Car Why text while the guard floor flag toggles' (#266) from EV-16 into release/1.0
infra-pin / fresh (push) Failing after 1s
2026-11-21 16:08:07 +01:00
EV-16 reviewerandClaude 91cbdf2f43 EV-16 review round 2: pin the unread-SoC rule on the Why's live fallback
checks / unit (pull_request) Successful in 24m26s
infra-pin / fresh (pull_request) Failing after 2s
The fallback (no record yet, or a record of an ended episode) had no check;
reading floor_limited alone there survived test_ev16. Test only.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-21 12:37:06 +01:00
Claude (dev) c707eb4776 EV-16: time the Car Why hold on the control cycle, not on page reads
checks / unit (pull_request) Successful in 24m55s
infra-pin / fresh (pull_request) Failing after 1s
car_cycle ends with _car_why_tick (display only: control writes, never reads);
the Why reads the record. Adds read-gap tests (A, B, cover off/on), a long
guard-None test and a lower bound for the hold.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-21 11:23:13 +01:00
Claude (dev) b662d7171b EV-16: key the held Car Why to the car_over episode; add T16, T18 and N-id checks
checks / unit (pull_request) Successful in 25m43s
infra-pin / fresh (pull_request) Failing after 2s
Control bumps _car_over_ep at each start and end of car_over; the display
ignores a hold of another episode, so a read overlapping the end cannot bring
a stale text back.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-21 10:04:00 +01:00
Claude (dev) 3b1189cdbf EV-16: hold the Car Why text while car_over holds and the guard floor flag toggles
checks / unit (pull_request) Successful in 27m49s
infra-pin / fresh (pull_request) Failing after 2s
Display only: the 'are at' / 'give all they can' text changes only when the
other state has stood for 180 s (the car_over off hold); SoC unread is never
'are at'. Cleared when car_over drops, on unplug and with cover off.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-21 08:54:04 +01:00
admin 8150608317 Merge pull request 'EV-19: no floor alarm when the batteries first reach the reserve early in a Manual car session' (#265) from EV-19 into release/1.0
infra-pin / fresh (push) Failing after 1s
Reviewed-on: #265
2026-11-20 23:42:30 +01:00
ems-agentandClaude 77684ecfad EV-19 review round 2: pin the 50 W blind band and the car term of the stillness test
checks / unit (pull_request) Successful in 25m14s
infra-pin / fresh (pull_request) Failing after 1s
Test-only. Two unit checks in test_ev19.py: an honest step with a burst
that moves the meter's house side +/-60 W alarms in base's cycle, and
inside the band (0 W) the car explains at most the step's own cycle;
a car step offset by a burst at the meter is not discounted. They kill
RISE_STILL_W = 500 W and a stillness test without the car term.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-20 23:14:09 +01:00
ems-agentandClaude c2bb32ec93 EV-19 review round 1: discount a battery rise only while the meter has not moved
checks / unit (pull_request) Successful in 31m32s
infra-pin / fresh (pull_request) Failing after 1s
[Major] The rise discount applied to any rise, also one the meter
already shows, so an honest house step answered by one cycle of battery
power alarmed one cycle after base (review repro: T6 step + burst, R+6
instead of R+5). Now a reading above both earlier ones is discounted only
while the meter's house side (held - car; held alone when a car figure is
unknown) moved no more than RISE_STILL_W (50 W) since the last cycle.

Tests: the burst shapes (unit, meter in step and one cycle late;
controller, step at R+5 and R+30, 3 000 / 4 600 W) at base's second; the
"N6 unit" check tightened to the rise cycle; the RISE_STILL_W boundary;
a pin on EV-18's `_car_over_now` (mC); T10 restarts at R-1 and R (mE).
test_ev19: 144 of 144 here, 52 red on 43b0db7.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-20 22:13:19 +01:00
ems-agentandClaude 4950a2374f EV-19: no floor alarm when the batteries first reach the reserve early in a Manual car session
checks / unit (pull_request) Successful in 25m47s
infra-pin / fresh (pull_request) Failing after 2s
EV-15 rig F-B, reproduced on 43b0db7 (tools/ev19_reserve.py, T1 grid). At
the reserve inverter-b goes on following the house, so its output rises
in that cycle. The battery reading shows the rise one cycle before the P1
sample does, and EV-18's house figure (held - car + now - min(now, prev))
counted the new battery power as house load. `_car_need_house` latched:
one PEAK_GUARD_FLOOR_LIMITED ERROR and goodwe_peak_soc_floor at R+1, red
until the guard stopped wanting power.

ctl_car._car_explains_alarm: for the house latch only, a reading above
both earlier readings counts as house only up to the higher of them. The
credit stays the lower of the last two readings. The claim, floor,
setpoints and charger writes are unchanged (342 runs, same digests).

test_ev19.py: T1-T17, T20, N1-N6 of reports/EV-19-test-plan.md; 49
checks red on 43b0db7, 124 of 124 green here.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-20 20:16:25 +01:00
ems-agent 43b0db73d2 Merge pull request 'EV-18: no floor alarm at a quarter's start while the car explains the excess' (#264) from EV-18 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-19 15:13:33 +01:00
ems-agentandClaude ef8c5dcf62 EV-18 review round 3: the DECISIONS line and a comment say what the contradiction latch does
checks / unit (pull_request) Successful in 23m10s
infra-pin / fresh (pull_request) Successful in 1s
Wording only. DECISIONS/EV-04: a contradiction is a meter that answered and
fell short (an unknown reading is none), and it grades no alarm while the
guard's input keeps the figure. ctl_car.car_cycle: the car-over row keeps the
figure only with the cover off.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-19 13:02:02 +01:00
ems-agentandClaude 93c6628eca EV-18 review round 2: the contradiction latch touches only the alarm; an unknown energy reading is not a contradiction
checks / unit (pull_request) Successful in 27m50s
infra-pin / fresh (pull_request) Successful in 2s
- [Critical] The latch set `w = None` before `_car_quarter`, so with cover
  off the guard's input (`car_exclude`) counted the car as house and the
  batteries discharged. The latch now changes only the figure graded for the
  alarm; the car's energy count, the guard's input and the car-over row keep
  the unlatched `car_alarm_w()`. Cover-off N4 twins (energy gap, T9(c) liar,
  SoC 60 % and at the reserve) give the same commands as without the latch.
- [Major] `corroborated()` is False for an unknown energy reading, so one
  missing reading latched a correct figure for the quarter. New
  `CarTracker.contradicted()`: only a meter that answered over a whole window
  and fell short. R1 (energy entity unknown 1 s at E+200, T2 and T3 shapes):
  red for that cycle only, explained from the next.
- Minors: unit checks that a contradiction in our own pause latches nothing
  (MF) and that the latch ends with the quarter (MG).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-19 12:18:06 +01:00
ems-agentandClaude 5db56b5f28 EV-18 review round 1: restart keeps the house's done part; contradicted figure untrusted to the quarter's end
checks / unit (pull_request) Successful in 29m3s
infra-pin / fresh (pull_request) Successful in 2s
- [Critical] After a restart or a gap only the rest of the quarter was graded
  without the car (`_carq["whole"]`), which dropped the house's own energy
  from before it and hid an honest alarm (review repro: house 18 kW then
  12 kW, restart at E+310). The rest-only grading is gone: the car is
  credited only with energy counted since the start, the rest of what is
  done counts as house (base's side). T17b covers it; T17 T2 at E+300 now
  alarms from the restart (the conservative side).
- [Major] Owner 2026-11-19: a figure the energy meter contradicted (fresh,
  charging, not corroborated) stays untrusted to the quarter's end, also as
  the EV-15 stand-in. T9(c): one alarm edge, red to the end; T9(c) is back
  in the N5 check.
- [Major] T2c lagging-meter variant (readings 389 W then 800 W, the meter at
  800 W): the house latch grades on the lower reading.
- Unit stub: a run that starts mid-quarter has the car counted since the
  quarter's start (no restart).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-19 11:28:04 +01:00
ems-agentandClaude 12c97b56f4 EV-18: no floor alarm at a quarter's start while the car explains the excess
checks / unit (pull_request) Successful in 23m6s
infra-pin / fresh (pull_request) Successful in 2s
EV-15 rig F-A: with both batteries at the peak reserve and the car charging,
PEAK_GUARD_FLOOR_LIMITED and goodwe_peak_soc_floor fired at a quarter's start
and stayed red for the quarter, the excess smaller than the car. Two causes,
both held by the per-quarter latch `_car_need_excl`:
- C2: "without the car" assumed the batteries give 0 W from now on, so what
  the loop still gives below the reserve counted as house (T2 red on base);
- C1: one cycle with no trusted car figure latched it for the quarter (T1).

Owner 2026-11-19 (Q1-Q3): without the car the batteries keep giving what they
give now (lower of two readings, every cycle); a house need seen with a
trusted car figure stays latched to the quarter's end (`_car_need_house`); an
unknown car figure keeps the alarm only while it is unknown. A car known to
draw nothing (fresh reading, not charging) still grades the house's own need.
After a restart or a gap only the rest of the quarter is graded without the
car. A 0 W figure explains nothing outside our own pause (EV-15). The guard's
claim, floor, setpoints and charger writes are unchanged (N4: 41 runs, same
command digests as base).

test_ev18.py: the test plan's T1-T18, T2b, T2c, N2-N5 (tools/ev18_peak.py:
the real Controller across one quarter edge, N=2 at the reserve).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-19 02:59:50 +01:00
admin 9fdce023e9 Merge pull request 'EV-15: the add-on's own phase change at the peak reserve raises no false alarm' (#262) from EV-15 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-17 17:15:51 +01:00
glenn schrooyenandClaude Opus 5.5 7788543e09 EV-15 review: reflow the _car_own_pause docstring (one 123-char line)
checks / unit (pull_request) Successful in 22m10s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-17 16:51:41 +01:00
glenn schrooyenandClaude 6d7046fc45 EV-15 round 2: the grace opens when the 0 A write is sent
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
The writer runs beside the cycle and the car can stop before the write
returns, so no sequence existed yet and the latch set. Window now opens at
send (zero_sent_at), cleared on return; ends on another writer in the tail too.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 15:24:30 +01:00
glenn schrooyenandClaude 07f703d1bc EV-15: test_ev15 guards its own indexing (named absence)
checks / unit (pull_request) Successful in 21m47s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:39:11 +01:00
glenn schrooyenandClaude 2cfbc4aec8 EV-15: the add-on's own phase change at the peak reserve raises no false alarm
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:26:56 +01:00
admin f66048b287 Merge pull request 'Release 0.24.0' (#260) from release-0.24.0 into release/1.0
infra-pin / fresh (push) Successful in 2s
checks / unit (pull_request) Successful in 21m46s
infra-pin / fresh (pull_request) Successful in 1s
2026-11-17 08:38:29 +01:00
review-agentandClaude Opus 5.5 69a1ccce1f REL-0.24.0 review: CHANGELOG wording (false-alarm scope, MQTT for HA controls, OPT-31 car charger)
checks / unit (pull_request) Successful in 22m11s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 08:15:59 +01:00
glenn schrooyenandClaude 9a355144fc Release 0.24.0: version bump and CHANGELOG
checks / unit (pull_request) Successful in 23m22s
infra-pin / fresh (pull_request) Successful in 2s
Minor bump: car Manual mode (EV-04), car-alone peak alarm fixes
(EV-10, EV-11, EV-12, EV-10b). Two new options with defaults
(ev_batt_cover, ev_mode_start); existing installs need no option change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 07:19:58 +01:00
admin 628bde8013 Merge pull request 'EV-10b: grade the alarm on the house alone, no 0 W clip' (#259) from EV-10b into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-17 00:20:55 +01:00
review-agentandClaude Opus 5.5 ff2eebe28b EV-10b review: pin the done-part clip and the car's power now in test_ev10b
checks / unit (pull_request) Successful in 22m9s
infra-pin / fresh (pull_request) Successful in 1s
Two checks a mutant survived: crediting the car-made export in the done part,
and taking off the car's quarter average instead of its power now.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-16 23:58:13 +01:00
glenn schrooyenandClaude b12776c705 EV-10b: grade the alarm on the house alone without the 0 W clip
checks / unit (pull_request) Successful in 22m5s
infra-pin / fresh (pull_request) Successful in 2s
The period without the car was clipped at 0 W, so batteries covering the car
were charged to the house and the floor alarm fired (rig F-1). New
car_exclude_alarm keeps the sign of the rest of the period; car_exclude (the
cover-off guard input) is unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 22:16:29 +01:00
admin b86c0153cf Merge pull request 'EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write is not another writer' (#258) from EV-10 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-16 20:54:30 +01:00
Claude 269b89d6b0 EV-10 round 3: grade the floor case on the same landing with and without the car; per-quarter latches independent of the cover option; stricter write-mute test
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 19:28:02 +01:00
Claude 646f61e730 EV-10 round 2: judge the car against the alarm's own landing; test failed writes; honest hold wording
checks / unit (pull_request) Successful in 22m4s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 18:07:25 +01:00
Claude a60342e4e8 EV-10: test_ev10 points at MUTATION.md and guards its indexed reads
checks / unit (pull_request) Successful in 20m36s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 16:12:42 +01:00
Claude 50d5ae90d2 EV-11: the end of a charging session clears the car-over state at once
checks / unit (pull_request) Failing after 29m5s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:41:57 +01:00
Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
admin 75ebe22a4d Merge pull request 'EV-04: car Manual mode, never throttled for the peak, no false guard alarms' (#257) from EV-04 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-16 09:21:04 +01:00
glenn schrooyenandClaude 6e6344eb02 EV-04 round 3: guard the L4 test's reads for test_named_absence
checks / unit (pull_request) Successful in 21m33s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 08:22:16 +01:00
glenn schrooyenandClaude f31dcb62b6 EV-04 round 3: undo restores the current in shadow mode too, energy rule catches a frozen 6 A figure, settle after a refused select
checks / unit (pull_request) Failing after 21m10s
infra-pin / fresh (pull_request) Successful in 1s
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 07:59:15 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
admin b65609133e Merge pull request 'Release 0.23.0' (#255) from release-0.23.0 into release/1.0
infra-pin / fresh (push) Successful in 1s
checks / unit (pull_request) Successful in 23m0s
infra-pin / fresh (pull_request) Successful in 2s
Release 0.23.0 (#255)
2026-11-16 03:55:37 +01:00
glenn schrooyenandClaude Opus 5.5 568230c422 Release 0.23.0: CHANGELOG review wording fixes
checks / unit (pull_request) Successful in 20m52s
infra-pin / fresh (pull_request) Successful in 2s
- MAINT-28: say the hold is for two inverters (the code gates it on N >= 2).
- EV-03: "no longer buy energy for the car" (the profile is a 7-day median).
- TEL-19: plain wording for the PV sensor point.
- Known issues: add TEL-20 (DOCS names a car sensor id HA does not create).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-16 03:34:13 +01:00
glenn schrooyenandClaude e3cce25cb0 Release 0.23.0: one Known issues heading
checks / unit (pull_request) Successful in 22m6s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-16 02:36:58 +01:00
glenn schrooyenandClaude 8af35172a3 Release 0.23.0
Bump version to 0.23.0 and fold "Not in a release yet" into a new
0.23.0 CHANGELOG section (MAINT-28, CI-17, EV-03, CI-18). Four new
options (ev_*), all with defaults; no option change needed.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-16 02:35:46 +01:00
admin 5fc92cf6e8 Merge pull request 'CI-18: affected-test selector for dev rounds, split the longest test files, 10 workers' (#254) from CI-18 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-16 00:31:50 +01:00