goodwe-agent 02c0a3dd7b MAINT-10: maintenance start hour in local time, default 19:00
The start hour was compared with the UTC hour, so the shipped 10 started at
12:00 in a Belgian summer. It is now read in Home Assistant's time zone
(fallback: the container's TZ, then UTC, one log line says which), and the
default moves to 19. DST: a missing hour starts at the first hour after the
jump; a repeated hour starts only in its first pass. Stored options are not
rewritten: a saved 10 now means 10:00 local (DOCS, CHANGELOG).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:52:05 +02:00
goodwe-review 516bc8b4ec Merge release/1.0 into safety-78-drain-at-two
checks / unit (pull_request) Successful in 18m49s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 21:53:47 +02:00
adminandClaude Opus 5.5 f967073cfe SAFETY-81 review: 10 s hold, ERROR line per episode, more scenarios
checks / unit (pull_request) Successful in 20m31s
infra-pin / fresh (pull_request) Successful in 2s
- The alarm must hold for peakguard.ALARM_HOLD_S (10 s) on the projection's
  clock. A load that tops cap + battery for ~5 s every 30 s alarmed at every
  quarter start while the quarter landed under the aim (sine4500_fast).
- A cycle with no battery reading leaves the hold alone.
- Notified once per quarter, but the ERROR line is written per episode.
- New sim scenarios (sine4500_fast, twice7000, step6500_gap) with 5a4cdc2
  digests; control still byte-identical. Unit checks for export and the
  hold across a missing reading. test_peakguard's saturated fixture moves
  the hold start back instead of waiting it out.
- DECISIONS and DOCS updated: costs of the hold, tolerance reasoning, the
  double count in control left to a follow-up.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 20:58:37 +02:00
goodwe-agent 6eb67c0f9c SAFETY-81: no false 'Load too high' alarms
checks / unit (pull_request) Successful in 16m11s
infra-pin / fresh (pull_request) Successful in 1s
The alarm now also needs peakguard.load_too_high(): with the battery at
full power, the quarter still ends more than 10 W over the real limit.
The battery reading is the lower of this cycle's and the last, so a meter
sample from before the battery's last increase is not counted twice.
At most one alarm per quarter. Control outputs unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 19:55:38 +02:00
Claude 5d27f8496f SAFETY-78: maintenance drain at N=2 no longer stalls
checks / unit (pull_request) Failing after 17m13s
infra-pin / fresh (pull_request) Successful in 2s
At two inverters the drain pins its pack and the site target is split
around the pin. Below the pin the other pack had to charge, the allocator
refused the opposite directions, and the site sat at 0 W with an ARBITER
line every cycle (house below or above the drain rate, or a grid charge).

main.py now files a site limit `drain` (lo = what the pin places, at
P_MAINTENANCE) at N>=2 while a pack drains, so the other pack only adds
power in the same direction. A drain that cannot give power waits with
one log line. With battery modes on, no grid charge while a pack drains,
and the other battery's card says why. N=1 is byte-identical.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 19:52:51 +02:00
Claude dev agent 6dab4ec16b OPT-11 P3, owner option A: selling off, Leftover solar takes solar only
checks / unit (pull_request) Successful in 15m12s
infra-pin / fresh (pull_request) Successful in 1s
Owner decision 2026-09-29. Selling is off until it can be judged on the price
the grid pays: packmode.SELLING_ENABLED = False makes read() answer
sell=False whatever the store holds, pack_sell is refused ("Selling is off
for now."), and the page has no selling switch; the sell code stays. Until
the P4 forecast, only Cheap hours only charges from the grid
(packmode.GRID_CHARGE_MODES); Leftover solar holds and gives in the
expensive runs. Help, Today and plan lines, DOCS and DECISIONS follow.
Replay, 16 days: Solar first + Leftover solar 19.44 EUR net (P2 19.33).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 10:42:58 +02:00
Claude dev agent 902524ae5e OPT-11 P3: price runs per battery
checks / unit (pull_request) Successful in 13m45s
infra-pin / fresh (pull_request) Successful in 1s
Cheap and expensive hours as runs of consecutive firm price slots
(priceruns.py); each battery's role per tick from its mode (modetrade.py):
grid charging for Leftover solar / Cheap hours only, never Solar first;
holding for the expensive runs; selling per battery (pack_sell) above the
spread and the floor. The site trade is sized inside the modes (loop bound)
and the peak guard's headroom; a run edge reseeds the loop. Cheap hours only
and selling are enabled on the Batteries screen and in the HA select
(appended). The site Why row no longer says "held back" when the peak limit
pushes power up (F2). Modes off: byte-identical to 7a00f12 on the trade path.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 02:37:44 +02:00
Review AgentandClaude Opus 5.5 e6096d3e17 Merge release/1.0 (7337b79, OPT-11 P2) into safety-79-peak-margin
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 00:23:14 +02:00
adminandClaude Opus 5.5 c664e38ef4 OPT-11 P2 review: refusals stay counted, removals survive a start with no broker
- A refusal past the log-once set or the 32 cap is counted in the log at
  1, 10, 100 and so on, so a repeated attack stays visible.
- The logged topic is printable only (no forged log lines).
- mode_announcement(): the start-up store logic, now tested with a real
  Store. A removed config topic stays stored, so a start with no broker
  cannot forget it (rename case tested).
- A test ties each HA mode option to the page's English name.
- packmode.enabled() is tested for "true", 1 and "false".
- Retained-command text, DOCS and DECISIONS updated to match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 23:58:34 +02:00
adminandClaude Opus 5.5 b310282729 OPT-11 P2: HA entities for battery modes
checks / unit (pull_request) Successful in 11m12s
infra-pin / fresh (pull_request) Successful in 2s
Each battery gets an MQTT-discovered Mode select and Use switch, only while
battery_modes_enabled is true. Commands go through handle_action(), the
/action path; refusals are logged once. Retained commands are never applied.
Turning modes off removes exactly the configs announced (kept in the store).
With modes off the announcement is byte-identical to ed739d4.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 23:12:04 +02:00
glenn schrooyenandClaude Opus 5.5 7c4c8f5c66 SAFETY-79: peak guard keeps a margin below the limit
checks / unit (pull_request) Failing after 11m34s
infra-pin / fresh (pull_request) Successful in 1s
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.

peak_margin_w 0 is byte-identical to ed739d4 (tools/safety79_identity.py,
test_peak_margin.py part 1). validate.py rule 12 refuses a value outside
0-500, not whole, or not below the peak limit.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 23:09:39 +02:00
glenn schrooyenandClaude Opus 5.5 ffc9a4d721 OPT-11 P1 review: a mode never beats the peak floor; SAFETY-03 kept at the rail
checks / unit (pull_request) Successful in 11m4s
infra-pin / fresh (pull_request) Successful in 2s
- arbiter: a mode now gives way only as far as a site limit above P_MODE
  needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
  released only when the peak floor bound S, so a trade won above the floor
  kept them and placed less than the floor (an Off battery at N=1 went to 0 W
  under a 2000 W floor), and a capped grid charge released an Off battery.
  While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
  rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
  (peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
  loop bound counts live units only). DOCS and DECISIONS say the new rule.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 19:41:36 +02:00
Claude dev agent d69fd8fbfd OPT-11 P1: per-battery mode limits, on/off, solar order
checks / unit (pull_request) Successful in 10m59s
infra-pin / fresh (pull_request) Successful in 1s
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.

compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).

Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 18:51:29 +02:00
Claude dev agent 667b8e9145 UX-13 P5: Dutch text, STYLE check, DOCS screenshots, period editor
checks / unit (pull_request) Successful in 10m45s
infra-pin / fresh (pull_request) Successful in 1s
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English
  fallback per key; the page picks by browser language. Home's sentences
  move into ui_text `home_words`, so /status?lang=nl builds them in Dutch.
- test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon
  lists for both languages, no inline details, untranslated Dutch caught.
  Shared rules moved unchanged to tools/style_rules.py.
- tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in
  headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot.
- "Other time windows": a list editor (ui.periods) that builds
  static_profile and names bad times, empty prices, overlaps and gaps.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 16:33:32 +02:00
adminandClaude Opus 5.5 159d7461d8 UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.

Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
  its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
  changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 08:48:21 +02:00
glenn schrooyenandClaude Opus 5.5 06aa09e28c SAFETY-73 review: a refusal needs 22 s of evidence, and the cut-out warning is for giving only
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 10m11s
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) *
  LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both
  units 10-16 times an hour after load steps (site held 0 W). 2 s and slower
  ticks are unchanged.
- REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that
  stops taking charge is always above its cut-out level.
- test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal;
  the release/1.0 checks are restored and a span check added.
- test_refusal_units: lagged-reading and full-battery plants, two new checks,
  U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 02:16:24 +02:00
glenn schrooyenandClaude Opus 5.5 1a9c7523c9 Merge release/1.0 (a36dca6) into SAFETY-73-per-unit-refusal
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 01:41:54 +02:00
Claude f8d63cc614 UX-13 P1: page shell and Home screen on a structured /status
checks / unit (pull_request) Successful in 9m37s
infra-pin / fresh (pull_request) Successful in 2s
- app/static/{index.html,app.css,app.js}: tabs (Home, Batteries, Settings,
  Setup), hash routes, phone bottom tabs, light/dark. Served inlined at "/";
  the route list is unchanged, and every URL is relative.
- app/homeview.py: /status gains state, now, batteries, plan, attention,
  month_peak and control beside the old fields. The plan is what the add-on
  does today: the arbitrage verdict (the same plan.arbitrage() call as the
  cycle), the monthly cycle, the peak limit, "follows the house".
- The Home plan chart has hover, tap and keyboard-focus tooltips: price bar =
  hour and price; block = what, when, why, kWh and EUR.
- Region preset and year: in config/model (for P2) and on the Home price line.
- test_home.py; test_messages part 8 scans every Home sentence; STYLE plan line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-28 00:45:01 +02:00
glenn schrooyenandClaude Opus 5.5 016ed5a5a3 SAFETY-73: a battery that refuses, per inverter, with two or more
checks / unit (pull_request) Successful in 10m1s
infra-pin / fresh (pull_request) Successful in 1s
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R).
A unit that gives < 100 W for 12 cycles in one direction while asked
> 200 W, or trips its stale-reading gate on a ~0 W reading, gets a
P_SAFETY `refused` unit limit closing that direction, so the allocator
hands its share to the others within their own limits. Probe: a +-200 W
pin every 15 min, one unit at a time, only while the site asks 200 W that
way. All units refusing: the site law holds 0 W. Exits reseed the site
target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above
the configured cut-out; SAFETY-42/43 no longer report a refusing unit.
N=1 unchanged.

test_refusal_units.py: cases a/b/c on flat and jitter registers against
the old behaviour, probes, recovery, exits; mutations U1-U13 all red.
TEST-19 no-fault campaign: 0 engagements in 5280 runs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 00:13:26 +02:00
adminandClaude Opus 5.5 3c0f2b9669 SAFETY-52 review: a refusal is under 100 W, and any delivery ends it
checks / unit (pull_request) Successful in 9m22s
infra-pin / fresh (pull_request) Successful in 1s
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's
  own 100 W answer, not below saturation_w: a battery derated to 100-499 W
  was held at 0 W ~93 % of the time.
- A reading of 100 W or more in the held direction ends the refusal, probe
  or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy
  reading's lag, and that held a healthy step at 0 W until the next probe.
- test_refusal part 5b and a seed test; DOCS states the N>1 limit; the
  DECISIONS record carries the traced cause of the replay's extra trips.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 18:11:42 +02:00
glenn schrooyenandClaude Opus 5.5 1f97c7652f SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Failing after 9m32s
At the BMS cut-out the saturation freeze held the last request for hours
(+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid
error changed sign. compute() now carries a refused direction: after
SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction
at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go
on charge, an answered probe, stop/start or another writer. A stale-reading
trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's
~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A).

test_refusal.py drives the real Controller and gate; tools/replay_refusal.py
replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined
where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what
SAFETY-58/59 must take into account.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 16:43:27 +02:00
adminandClaude Opus 5.5 3c298af3d8 UX-11 review: restored stops log their figures to events, the quiet-meter WARNING is rate-limited
checks / unit (pull_request) Successful in 9m7s
infra-pin / fresh (pull_request) Successful in 1s
- After a restart, each restored stop (direction per inverter and site,
  delivery, circulation) also writes its saved reason to the action log.
  log_level defaults to info and events starts empty, so the DEBUG
  evidence alone left the figures only in state.json.
- A flapping meter (ha_signed under a flat load, 42-97 s between changes)
  logs at most one WARNING/INFO pair per 10 minutes, with the episodes in
  between at DEBUG.
- LONG_LINE_OK refuses any key whose text is a safety reason.
- test_watchdog keeps the byte pin beside the meaning pin, since the text
  did not change.
- DOCS says the DEBUG line needs log_level debug.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 14:21:05 +02:00
glenn schrooyenandClaude Opus 5.5 c628099e69 UX-11: the meter WARNING names the limit only, as 'over 30 seconds'
checks / unit (pull_request) Successful in 9m4s
infra-pin / fresh (pull_request) Successful in 2s
TEST-23 showed 'No meter reading for 30 seconds, over the limit of 30
seconds': the age is 30.4 s, which rounds to the limit. The limit alone is
always true at the moment the line is logged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 13:49:17 +02:00
glenn schrooyenandClaude Opus 5.5 29837dfaa7 UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
- Every WARNING/ERROR line that reported a safety reason (direction, delivery,
  stuck meter, stale reading, peak guard, circulation, over-rating) now ends in
  the reason's code (messages.reason_code()). The reason itself, figures and
  limits included, is on a DEBUG line right after it and in the action log.
- The reasons and state.json are unchanged, so an old state file loads and
  shows the same way: every saved reason opens with its code.
- test_messages part 6 checks every WARNING+ line at 25 words as logged; nine
  non-safety families are listed with a reason and capped. The byte pin in
  test_watchdog now pins the meaning, in order.
- The meter logs one WARNING per quiet episode, and INFO when back, so the red
  row's "the add-on log shows why" holds. The Why line past the hold names
  the missing reading. Action log: "25 engagements", "Shadow mode off: ...".

No trigger, latch, threshold, log level, notification id, cadence, row colour
or banner order changed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 13:34:30 +02:00
adminandClaude Opus 5.5 e0b578756f UX-10 review: the line as logged gets the red-alarm shape, clamp lines at 30 words, plain HA 400
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
Part 6 checked the quoted reason alone, so title + reason + tails logged
as 4+ sentences. It now also checks the whole line (at most 3 sentences,
none over 30 words); 25 lines failed and are rewritten (one-sentence
wrappers, two-sentence circulation and peak reasons, STALE_READING's
fixed limits on a DEBUG line). The clamp lines for one inverter are
pinned at 30 words with OUTPUT_CLAMP and the numbers kept. Home
Assistant's bare '400: Bad Request' while it loads becomes one plain
line; still WARNING, throttled, a failed write.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 12:08:38 +02:00
glenn schrooyenandClaude Opus 5.5 23a3a3f5b5 UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified
  as data or as a built text, and every built text is produced by the real
  code and checked. This is the gap the 2d scan had: it counted `%s` as one
  word, so reasons built by loop_clamp_note() and friends were never seen.
- Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept):
  OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak
  guard (codes now PEAK_GUARD*), the migration report, price feed, price
  history and gate reasons. Plurals via messages.times()/count().
- Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff
  "one every 15 minutes or every hour", "not final yet" dropped.
- Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO,
  aiohttp access log only at log level debug, settings warnings once per
  start, one plain line per Home Assistant outage (hass.Outage).
- INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE",
  "NOT_OBSERVED", "did NOT land", "AND".
- Display bugs: WHY_WINNER covers every winner and safety reason
  (main.why_key(), part 7 finds them in the code); the meter row is amber
  "waiting for the first reading" inside its limit after a start; the
  missing-reading age is counted when the page asks.
- STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section).

No change to safety behaviour, alarm levels, notification ids, triggers,
cadence or the banner cascade. One row colour changes (meter at start),
justified in DECISIONS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 10:58:43 +02:00
Claude review 569f16aa91 UX-08 2d review: action log reachable in status JSON, engaged peak row pinned, imported keys expanded
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 8m54s
- status_payload() also returns the action log as `events`. The page
  does not render it. Some entries (a dropped inverter's reason, the peak
  guard's projection, unplaced watts) are written nowhere else, and DOCS
  still points installers at the action log.
- test_peakguard pins the engaged row's ordered pair (the battery's share,
  then the limit).
- test_messages expands setting keys named by constants imported from
  another app module, so the shown-text 30-word scan counts them.
- p1.py: 'A meter message could not be read'. DOCS glossary: control
  board in plain words, with the hardware in an installer note.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 08:29:14 +02:00
adminandClaude Opus 5.5 6a95447248 UX-08 2d: plain log lines, the rest of the status page, and DOCS
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 8m55s
Every WARNING and ERROR line is one plain line of at most 25 words, with
no card ids, capitals or semicolons; the reasoning of the ten longest is
on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0).

The status page: the month-peak and peak-guard rows, the stale-reading
row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the
Stopped banner and the line under the buttons, which now shows the plain
hint of each event instead of the raw action log. The Supervisor question
at start logs one line with a real reason.

Refusals are counted as shown (labels expanded, long cases driven), seven
were shortened, the card and parse errors lost their internals, a blank
value reads "empty", and the panel no longer files inverters.max_w under
the flat max_w. Option names lose "(JSON)", the NL texts are checked too.

DOCS gets a glossary (control board, isolator, Developer Tools) and card
ids move from headings to a "For installers" line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 08:01:16 +02:00
adminandClaude Opus 5.5 63dee6db1e UX-09 review: short start-up timeout, latch rows pinned in shadow, plainer rows
checks / unit (pull_request) Successful in 8m50s
infra-pin / fresh (pull_request) Successful in 1s
The Supervisor questions for the Details link are asked together with a
3 s budget instead of one after the other at 10 s each, so a hung
Supervisor cannot hold control start for 20 s. In shadow mode the
circulating and site-direction latches are pinned to keep their own red
row that says how they clear. Plainer inverter and battery wording.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 04:45:06 +02:00
adminandClaude Opus 5.5 00e3ee9de8 UX-09: Details link for current HA, "would" in shadow mode, plain terms
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Successful in 8m50s
- Details link: /config/app/<slug>/documentation on HA 2026.2+ (the old
  /hassio/addon path is a 404 from 2026.5), /hassio/addon on 2026.1 and
  older. Slug from GET /addons/self/info, version from GET /info, hostname
  as fallback.
- Shadow mode: the over-rating alarm and row say what would have been sent,
  the peak alarm no longer says the battery is giving all it can.
- "controller" -> "the add-on" / "control". Settings named by their labels;
  four labels changed to match (Peak reserve, Battery level entity, Solar
  production ..., Reversed-sign solar entities).
- Shadow banner and inverter link notes moved to messages.py and checked.
- DOCS Notifications and Status page rewritten for home owners, with a
  "For installers" part each. Allowlist 168 -> 167.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 04:10:39 +02:00
glenn schrooyenandClaude Opus 5.5 571b884315 UX-08 phase 2b review: keep over-rating evidence, pin latch clearing, plainer rows
checks / unit (pull_request) Successful in 8m48s
infra-pin / fresh (pull_request) Successful in 1s
- During a bound episode an earlier over-rating count stays on the page (amber,
  under its own title); test_clamp pins it.
- test_messages pins that every latch row says how it clears.
- pv_entities description no longer claims the page names the entity (en, nl);
  allowlist hash updated for that option-desc line.
- Plainer texts: multi-inverter direction banner, "fine now" after an episode,
  and the e-stop, peak-forecast and peak-guard-waiting rows move to messages.py.
- TEL-12 DECISIONS points to UX-08 item 3 for the retired row rule.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 03:10:25 +02:00
adminandClaude Opus 5.5 d017fc67bf UX-08 phase 2b: short, plain status rows and page banners
checks / unit (pull_request) Successful in 8m47s
infra-pin / fresh (pull_request) Failing after 1s
Every Commissioning row and every page banner is now worded in
app/messages.py (row_*, banner_*): one sentence of at most 15 words, a red
row up to three sentences so a latch still says how it clears, banners at
most 12 words. No row names a Home Assistant entity: sensors by their
setting, solar sources by their place in the list. Reason codes and limits
stay on the log line and event list; rows keep the numbers a reader acts on.

UX-07 item 1: ClampWatchdog counts over-rating and integrator-bound
engagements separately, and after an episode each count shows under its own
alarm's title instead of both under "output clamp".

No row colour, visibility or banner order changed. Rows carry an "id" so the
tests pin meaning rather than wording. The row and banner kinds leave the
allowlist (200 -> 168, cap equal). DOCS.md gains "Status page"; choices are in
DECISIONS/UX-08-short-notifications.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 02:12:10 +02:00
adminandClaude Opus 5.5 7b65a3e69a UX-08 review: tighter notification texts, and two meaning fixes
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 8m48s
- not delivering: the body said control keeps running and then "start
  control"; clearing it takes stop then start, and it now says so.
- peak reserve: the "reserve not set" branch is really soc_floor None,
  i.e. an inverter's cut-out level missing; it now names that. The title
  is true on all three branches ("Battery stopped limiting the peak").
- no semicolon run-ons in bodies (STYLE.md + test); loop-bound, circulating,
  meter-frozen and multi-unit over-rating bodies rewritten to match.
- allowlist cap is now exact, so a shrink cannot leave room to regrow.
- DOCS names the settings behind "peak reserve" and "cut-out level";
  DECISIONS no longer states the HA anchor behaviour as fact.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 01:18:55 +02:00
glenn schrooyenandClaude Opus 5.5 50ccea3dd7 UX-08 phase 2a: short, plain notifications, and a ratchet for the rest
checks / unit (pull_request) Successful in 8m54s
infra-pin / fresh (pull_request) Successful in 1s
Every HA notification the add-on raises now has a title of at most 5
everyday words and a one-sentence body; a red alarm may use three so no
action is lost. The texts live in app/messages.py, the rule in STYLE.md,
and the detail that moved out in DOCS.md "Notifications", which each body
links to. No notification_id, trigger or cadence changed.

test_messages.py enforces the rule on every notification, fails any
notification worded outside app/messages.py, and ratchets the kinds not yet
rewritten (rows, banners, refusals, logs, options) through a shrinking
allowlist of 200. Six tests re-pinned from prose to meaning.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 01:00:54 +02:00
glenn schrooyenandClaude Opus 5.5 55a6d5dcdb SAFETY-40 review: integrator-bound WARNING gets its own notification id
checks / unit (pull_request) Successful in 8m46s
infra-pin / fresh (pull_request) Successful in 1s
A later anti-windup notice could replace a write-path BUG SIGNAL notice
under the shared goodwe_output_clamp id (escalation ignores the budget).
The WARNING now uses goodwe_integrator_bound and points to DOCS; the
cadence sentence in DOCS is corrected. Tests pin both ids (red on fd14569).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 23:08:44 +02:00
glenn schrooyenandClaude Opus 5.5 fd14569a71 SAFETY-40: the integrator bound is not a BUG SIGNAL; numbers from the clamp tick
checks / unit (pull_request) Successful in 8m47s
infra-pin / fresh (pull_request) Successful in 1s
The clamp alarm gave `i_clamped` (normal anti-windup) the over-rating BUG
SIGNAL text, printed `Decision.i_w` as "the loop asked for", and printed
`self.target` (after slew/freeze) as "was clamped to".

- clamp.loop_clamp_note(): i_clamped says "the loop's integrator reached its
  N W anti-windup bound" with this tick's command; clamped keeps BUG SIGNAL
  with the requested command and the clamp's own result.
- Decision carries i_bound_w / requested_w / clamped_w, set at the clamp.
- i_clamped still counts and notifies (same id, cadence, SAFETY-41
  escalation) but as a WARNING, amber row, plain title. A bug has its own
  notification budget and its text is not overwritten within an episode.
- test_clamp.py part 9: red on the old code per defect; 5 mutations killed.
- DOCS.md alarm section (and its stale 30 s cadence), DECISIONS/SAFETY-40.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-26 22:37:01 +02:00
glenn schrooyenandClaude Opus 5.5 6028e21298 SAFETY-34: re-assert latched alarms, because a Core restart keeps the add-on
checks / unit (pull_request) Successful in 8m55s
infra-pin / fresh (pull_request) Successful in 1s
A Core-only restart wipes persistent_notification and does NOT restart the
add-on (measured on TEST-23: the add-on's SAFETY-31 card was gone 4 min after
`docker restart test23-ha`, add-on StartedAt unchanged). The latched SAFETY-31
and SAFETY-42 cards were re-raised only on add-on start, so they stayed gone.

They are now re-asserted every REANNOUNCE_S = 300 s while tripped (same
notification_id, so it replaces). test_watchdog part 6 and test_delivery part
8b grade it with the same process across the "restart"; red on the old code.
The docstrings that said the add-on restarts with HA are corrected.
Record: goodwe docs/DECISIONS.md, SAFETY-34 D4.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-26 12:37:47 +02:00
glenn schrooyenandClaude Opus 5.5 7559d21eda TEL-14: PV sign declared per entity (pv_invert_entities)
checks / unit (pull_request) Successful in 8m39s
Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive
for consumption and negative for production. `pv_invert_entities` lists the
ones to flip; the flip is applied per member inside pv.total(), before the sum,
so the MQTT `pv` row and the status page carry the corrected figure. Default []
is byte-identical to 0.12.0.

Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0):
a parallel list validates the 0.12.0 blob unchanged and renders as its own
translated repeatable field; dicts on pv_entities refuse 0.12.0's stored
strings; a prefix is invisible syntax; a global bool cannot describe a mixed
roster. Status page marks flipped entities and cautions per entity below
-50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged.

Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 00:25:24 +02:00
glenn schrooyenandClaude Opus 5.5 71d2d4a37a SAFETY-61: the control task's death ends the process, after the wind-down
checks / unit (pull_request) Successful in 8m22s
A done-callback on run_control()'s task logs the traceback at the death and
sets `stop`; amain() runs the ordinary wind-down (shutdown() ->
command_site_zero()) and main() exits 70 (EX_SOFTWARE). Normal stops and
run_control()'s refusal path are ignored by the callback (still 0 / 78).

hass.py: a malformed JSON body, a JSON non-object, and an undecodable error
body are an absence / a failed write, not an exception into the loop.

checks() gains a first "control loop" row, red past FIRMWARE_INGEST_VETO_S.

Why exit rather than restart in-process, and what the Supervisor actually
does on exit (restarts only with the per-install Watchdog toggle on, default
off): DECISIONS/SAFETY-61-control-task-death.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 23:52:42 +02:00
adminandClaude Opus 5 0ef9565071 TEL-12: several PV inverters, and one absent member is an absent TOTAL
checks / unit (pull_request) Successful in 7m59s
0.11.0 shipped `pv_entity` as a single string. The reference site's owner
reported within minutes of it going live that they have several PV inverters
and could configure one - which is ordinary for a multi-string roof, not a
property of one house. `pv_entities` is the roster and the row carries the
SITE total.

⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`,
and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL
ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no
irradiance" conclusion the channel exists to TEST. So `pv.total()` answers
`None` the moment any configured entity is absent: the topic carries HA's own
`None`, the entity goes to `unknown`, the recorder records a GAP. The
alternative (the partial sum beside a contributor count) was implemented and
run as mutation N1b; it loses because the MQTT row is read COLD a week later by
an attribution that would believe it, while the qualifying count would live in a
second entity with its own history. The partial information is not thrown away -
the STATUS PAGE names every entity that reported, with its watts, and every one
that did not, with its reason, because that surface is read LIVE by a human who
wants the diagnostic.

⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is
`is None`, never falsiness - a roster that blanked the site on a zero would
report an absence on every clear evening.

THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list:
tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an
0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and
deepmerge's list strategy is `override` so a `[]` default does not rescue it -
the live add-on would not start. `match(.*)?` does accept both shapes and is
rejected for a different, measured reason: it validates nothing (a string, a
list and the integer 417 all pass) and renders as a plain text box. So
`pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for
`inverters:`, with a status caution saying which key won - a union would
double-count the inverter the old key still names.

STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than
replaced and now grades five claims over three document sets. The control hash
is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the
roster control document is byte-identical between the two trees. 2/5 is a claim
TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly
as 0.11.0 does" is a real cross-tree identity over control AND telemetry.

⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit
24: a discriminator defined as "the baseline lacks this feature" dies on the
release that ships the feature, and dies as a false refusal.

Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B
(`sum` -> `max`, the same three characters) and was run on a fresh copy with
`cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO
contributions in two units with absence driven at EVERY position - a member
contributing 0 W could go absent without moving the sum of the rest, which is
habit 23 with a coinciding value in the arithmetic rather than in the plant.

31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0,
so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG
entry is wanted and deliberately not written - 11b forbids `## Unreleased` and
the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the
material it needs.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 22:13:25 +02:00
glenn schrooyenandClaude Opus 5 07ba3433ed TEL-11: PV production stops being invisible, and stays out of the control law
checks / unit (pull_request) Successful in 8m6s
OPT-10 measured that this site's pack reaches 90 % SoC on 2 days of 16 and that
20.5 kWh of surplus left the site while the pack had room - 12.6 kWh of it with
the battery not charging at all - and could not say WHY, because PV production
is recorded NOWHERE. Three causes need three different fixes (no irradiance:
nothing to fix; a charge-power limit; the optimiser declining to charge, which
is the only software defect) and guessing between them is how an optimiser gets
tuned to solve a cloud problem. This card adds the channel. It does not do the
attribution.

AN HA ENTITY, NOT A REGISTER, AND THAT IS A PRODUCT DECISION. This add-on's
RS485 bus carries the BATTERY inverter it drives; a household's PV inverter is
normally a different box from a different vendor reporting into Home Assistant
through its own integration. `pv_entity` takes whatever `sensor.*` the site's
own PV integration provides, any brand HA can read.

POSITIVE IS PRODUCTION, AND THERE IS NO `pv_invert`. The convention is derived
rather than assumed: `meter_entity` is positive when IMPORTING and `batt_entity`
is positive when DISCHARGING (DOCS.md, Sources), both of which are "power
arriving at the house's AC bus", and production arrives there too. Those two
keys carry invert flags because they are BIPOLAR and are READ BY THE CONTROL
PATH - `inv.batt` feeds SAFETY-30's per-unit sign check and SAFETY-31's
circulating-power sensor, so a reversed sensor hands the site a plausible number
it acts on. Production is unipolar and is read by nothing: a reversed sensor
announces itself as -4 kW at noon in the very history this card creates, and a
flag would only let an installer hide it. No negative-value alarm either - a PV
inverter's own standby draw makes a small negative reading at night ordinary, so
any threshold would be a number nobody measured.

ABSENCE IS NEVER ZERO, AND "DROPPED" IS NOT ABSENT. `publish()` SKIPS a None,
which is right for `circulation` and exactly wrong here: a skipped row leaves
Home Assistant holding the last number forever and the recorder draws a FLAT
LINE through the outage, which is indistinguishable from a measurement and
manufactures the "there was no surplus" conclusion this card exists to TEST. So
the absence is published, with HA's own payload: `mqtt/const.py` declares
`PAYLOAD_NONE = "None"` and `mqtt/sensor.py` tests it BEFORE the numeric branch,
so the entity's state becomes `unknown` and the recorder stores a GAP. Read out
of home-assistant/core `dev` on 2026-09-24 and quoted at the constant.
`ABSENT_AS_UNKNOWN` is a one-key set and the suite asserts `circulation: None`
is STILL dropped.

THE UNIT IS READ OFF THE ENTITY. `mW`, `W`, `kW`, `MW`, `GW`, `TW` - HA's own
`UnitOfPower`, every factor an exact power of ten. A sensor with no unit, or a
unit outside that table, is REFUSED by name and the status page says which.
`read_inputs()`'s `abs(raw) < 50` kW-or-W guess is safe for a quarter-hour
demand forecast and is NOT safe here: 30 W of dusk is an ordinary reading and
that heuristic would publish it as 30 kW.

GENUINELY OPTIONAL, AND NOT A SECOND `price_now_entity`. validate.py does not
mention the key - it cannot conflict with anything, because nothing else reads
it. The MQTT row lives in a new `OPTIONAL_SENSORS` list whose `include` argument
DEFAULTS TO EMPTY, so every caller that has never heard of `pv_entity` -
test_mqtt.py's fixtures, tools/rehearse_roster.py, anything written next year -
announces exactly what it announced before. Unset: no state call at all, no
entity, no topic, no status row, no page row. Set and failing: a CAUTION
(`ok=False, warn=True`), never a `bad` row, so a telemetry channel can never put
a battery site into NOT READY.

IT MUST NOT BECOME A CONTROL INPUT, AND THAT IS GRADED TWICE. `test_pv.py`
part 6 drives 40 cycles of the real `cycle()` and asserts the commands are
bit-identical across unset / no reading / 0 W / 8 kW, with a COMPUTED census
(33 modules under app/) showing the material is mentioned in exactly three:
pv.py, main.py, mqtt.py. `tools/tel11_pv_trace.py` is the cross-tree half -
`safety56_behaviour_trace.py`'s pattern with a DIFFERENT control clause, because
this card's claim is that nothing differs rather than that only sentences do: it
REFUSES unless the two `app/` fingerprints differ and unless exactly one side
reacts to the option. Measured on 41 stimulus cells:

    control   release/1.0 unset  846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    control   TEL-11      unset  846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    control   TEL-11      set    846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    telemetry release/1.0 unset  a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
    telemetry TEL-11      unset  a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
    telemetry TEL-11      set    4e6d1cb289a957223ad0205f732a6fec6110ce1f2032c98ad60694e67625274f

UNSET is byte-identical in BOTH documents, which is stronger than "the control
path is untouched": an install that does not set the option sees no change of
any kind, announcement and status rows included.

⚠️ AND THE CARD'S CENTRAL MUTATION WAS A SURVIVOR ON THE FIRST BATTERY.
`self.grid -= self.pv_w` in `read_inputs()` - +106 B, on disk, purged, genuinely
running - came back GREEN, because the fixture drove a 6 kW export over 12
cycles, which puts the loop AGAINST ITS RAIL: a command moving `slew_w` every
cycle produces the same ramp for -6000 W and for -14 000 W of apparent error.
MUTATION.md habit 23 with a saturated ACTUATOR in place of a coinciding value,
and it is in that file now as the habit's second instance. The fixture now
drives a 600 W import the loop SETTLES on, against a responsive meter, and asks
habit 23's own question as its own check: shift the METER by the same 8 kW and
confirm the commands really would have moved.

Evidence: 31/31 suites green in the CI image, checks.yml's exact command, purged
tree, `:ro`. Ten mutations, NO survivors, each on its own `cp -a` of the tree so
habit 18's revert hazard is closed by construction - table in
`DECISIONS/TEL-11-pv-production.md` §7 with byte deltas and sha256s.

⚠️ THIS IS A RUNTIME CHANGE BEHIND AN UNCHANGED VERSION, AND
`tools/predeploy_check.py` WILL REFUSE IT. `app/`, `config.yaml` and
`translations/` are all in its `RUNTIME` tuple and `config.yaml` still reads
0.10.1, so the gate reports a NO-OP deploy until a version is cut. That is PKG's
call and this card does not take it.

No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading
that is not config.yaml's `version:`, and opening one would mean taking that
same packaging decision. The operator account is in DOCS.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 15:35:07 +02:00
adminandClaude Opus 5 8a6acd9fa2 SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can
checks / unit (pull_request) Successful in 8m0s
Text only. No behaviour change - same conjunction, same limits, same MISSING,
same 0 W, same NOT READY. `tools/safety56_behaviour_trace.py` says so: 2390
capture reads, a 66-cell swept grid, and six driven controller worlds produce
the byte-identical document `6030175e...` on origin/release/1.0 and on this
branch, while the sentences differ.

THE DEFECT. SAFETY-37's conjunction is satisfied by two disjoint worlds - the
register has stopped reporting reality, or the SOURCE cannot comply with the
command - and nothing `freshness.py` is handed separates them. Three sentences
asserted the first. On the live 2026-09-21 episode it was the second: the pack
read 11 % for the whole 850 s hold, every command in that hold was a discharge,
and the register answered the first CHARGE command three seconds later. The
readiness row was worse still, because it asserted a false fact about a NAMED
entity that was present, numeric and updating - so the operator opened
Developer Tools, found it working, and had every reason to conclude the
diagnostics were broken.

THE FIX. Each message states what was OBSERVED and names BOTH explanations.
Three wordings, no shared helper: two are a log line about a behaviour, the
third is a banner about an entity, and a helper serving both would drop
whichever half the other caller does not need. SoC stays STATED, NOT WIRED -
part 11b drives the two worlds at 50 % and 11 % and the sentence does not move
one byte. The row does not branch on `batt_fresh.stale` either: `stale_note()`
already rides `liveness_notes()` a few rows below, so the discriminator is "is
that row there?", and part 11d asserts it is present in one world and absent in
the other.

THE CHECKS. test_freshness.py part 11 builds the pair of worlds with ground
truth written down rather than derived from the published stream, asserts they
are really two (40 of 40 reads differ) while the published stream is
bit-identical, and only then grades the sentences. Eleven mutations, all red:
each of the three sentences reverted (3, 2 and 2 named reds), the two
explanations transposed at ZERO bytes (1), the second explanation deleted (1),
the admission of ambiguity replaced by a ranking (1), all three reverted at
once (5), and two aimed at this card's own check - collapsing the world pair
(2) and emptying the accusation list, which a positive control against the
three sentences as 0.10.1 shipped them catches (1).

AND TWO OF THE ELEVEN FOUND DEFECTS IN THE CHECK RATHER THAN IN THE CODE.
Transposing `label` and `entity` in the row made it unfindable and the run died
on an IndexError - a red with no name and every later check ungraded, FCST-06's
shape exactly; `_s56_row()` returns a named absence now, 0 named reds before, 3
after. And the first invariance run compared a tree with itself, because it
archived a branch whose edits were not committed yet; the tool now REFUSES to
report "behaviour unchanged" unless the sentences halves differ, and both of
its refusals are driven.

SAFETY-57's part 10h check was the handoff and is inverted rather than deleted:
it required the accusation to still be present so that removing it had to be a
deliberate act. This is that act. Its escape clause is untouched.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-23 21:02:40 +02:00
adminandClaude Opus 5 43c144b8d9 SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.

REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:

  10:51:24.7  0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
              the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
  10:51:29.7  the command reaches +1060 W - 800 W of travel
  10:52:00    the conjunction arms. Inverter.batt becomes None
  10:52:21.7  the site commands 0 W, on the wire
  ...         0x0518 does not change value for 850.0 s. The setpoint does not
              change value for 790.0 s. The house exports 2.4 kW throughout
  ~11:04      a human restarts the add-on. That is what ends it

AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.

THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.

THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:

  the verdict is withdrawn when the obligation that produced it has been gone
  for RELEASE_S, and the register is then re-graded from scratch.

RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.

The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.

WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.

Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.

main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.

Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-21 12:33:56 +02:00
glenn schrooyenandClaude Opus 5 b548525d10 TEL-10: the loop's integrator stops being invisible
`self.i_w` has been a separate quantity from the command since SAFETY-04 and
has left the process nowhere at all - no entity, no MQTT attribute, no log
line. The investigation behind SAFETY-48 could only RECONSTRUCT it from the
grid trace plus a replay; the reconstruction reproduced about a third of the
engagements it was checked against and was discarded, so the card it was
gathered for had to be argued from a measurement nobody could stand behind.
It could not have been made to work either: `i_w` depends on every cycle
before it, including the ones where the arbiter overrode the loop and
`main.py` re-seeded `self.i_w = self.target`, and that re-seed is invisible in
the grid trace.

THREE SITE ROWS, APPENDED AFTER release/1.0's EIGHT. `loop_i` is
`Decision.i_w` - the accumulator after the cycle, before the output clamp, the
slew limit and quantisation. `loop_lead` is `decision.i_w - prev_w` against the
command `compute()` was HANDED, which is not a subtraction of the other two
published rows: `Setpoint` is the arbiter's output and is this cycle's, so on
any cycle the arbiter overrode the loop the two differ - and that is exactly
the cycle on which the integrator was re-seeded. `loop_reason` is
`compute()`'s own word; the arbiter's `explain()` prints the winning claim's
NAME and has never carried the claim's reason, so `slew-limited` appears in
neither the `Why` row nor `Controller status`. Measured on the same cycle:
arbiter `'loop -> -5000 W'`, loop `'i-clamped'`.

NOTHING IN THE CONTROL PATH MOVED. `app/control.py` is not in this diff.
`compute()`, its returned `Decision` and every constant it reads are identical
to release/1.0, and all nine of release/1.0's retained discovery messages are
byte-identical and still FIRST in the announcement.

Evidence: 30/30 suites green in the CI image. Nine mutations, ONE survivor,
reported as one: `decision.i_w - self.target` for the lead is +2 B and green
because `cycle()` has not reassigned `self.target` at that line - the name is
kept for the coupling, not for a behaviour it buys, and M2b (+8 B) is the
mutation that does change the value and is red.

AND TWO OF THIS CARD'S OWN CHECKS COULD NOT REACH THE FAILURE THEY NAMED.
"the published integrator reaches its bound" was GREEN under the card's named
mutation (publish `prev_w`, -3 B), because the command reaches the bound too -
twelve cycles later. It asserts the LEAD TIME now and is red on 5. "a stopped
controller publishes not-running" was GREEN under deleting that branch's
assignments (-45 B, -67 B), because the fixture STARTED stopped and `__init__`
writes the same values; it stops the controller part-way through a run that
has already wound the integrator to -5000 W. Both are MUTATION.md habit 4,
found by the battery rather than by review.

No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## `
heading that is not config.yaml's `version:`, and opening one would mean
taking a packaging decision this card does not get to take. The operator
account is in DOCS.md and the release note belongs to the next PKG ticket.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-18 23:36:23 +02:00
glenn schrooyenandClaude Opus 5 e3ccd9f6ea SAFETY-47: what a shadow run can show, and the watts on its status row
checks / unit (pull_request) Successful in 7m48s
Not a leak and not a write-path defect. Shadow mode's safety is intact -
the substitution, the re-seed, the authorisation gate and the clamp are
untouched. What was wrong is what three merged documents SAY a shadow run
can show you, and a number on the status row that can be 6.61x what a live
controller would command.

SHADOW MODE CANNOT SURFACE A CLOSED-LOOP DEFECT, AND THE DOCUMENTS NOW SAY
SO. The battery is held at 0 W and the carried command is re-seeded to it,
so every measured input - the meter, the billed-quarter accumulator behind
it, the battery power, the SoC - describes a plant that did not respond. A
closed-loop defect is one whose stimulus IS that response. This is the same
property that makes shadow mode safe, so it is not a gap to close later:
the closed-loop answer comes from the closed-loop rig or from a live run.
SAFETY-10 §5 already conceded this for the grid-following loop. It was
never the loop leg's limitation; it is the general case.

THE "STRATEGIES ARE UNAFFECTED" EXEMPTION WAS TRUE UNTIL SAFETY-45 MERGED,
ONE COMMIT EARLIER. That card sizes the buy leg as min(asked, headroom)
with headroom = (900/remaining) x (ceiling - projected), and `projected`
reads the open quarter's accumulator - the meter - which is a function of
what the battery did earlier in that quarter. Measured on TEST-23 stage 3
at peak_cap_w 1500 / house 1200 / max_w 2000, one hour at 5 s:

  SAFETY-45's limit cycle  NOT visible. 28 onsets live vs 1; grid
                           -455.5..+3200.0 W vs flat at the 1200 W house;
                           guard engaged 410/720 cycles vs 0/720.
  SAFETY-46's SoC churn    NOT visible. The SoC moves 0.000000000 pp.
  TARIFF-14's wrong hour   VISIBLE, and it is the only one: which hour, at
                           what price, clearing what spread - identical on
                           720 of 720 charging cycles at a binding cap.

The exemption narrows to exactly what survives: WHICH hour a strategy picks
and WHY are unaffected; HOW HARD it trades is not. The peak guard's ceiling
and reasons are worth reading from a shadow run; its ENGAGEMENTS are not.

THE NUMBER IS CAVEATED, NOT RE-COMPUTED, AND THAT IS THE DECISION. The
arithmetic is not wrong - 900/remaining is correct for a meter genuinely
under the ceiling, and in shadow the meter genuinely is. It is the right
answer to a question nobody asked. Both surfaces now introduce the watts as
what would have been commanded ON THIS CYCLE, in every state, and carry
shadow.SIZED_FROM_METER whenever a measured billed quarter sized them.
Rejected, and recorded in the decision doc: re-computing it (the recorded
decision would no longer be the decision the shipped path reached, while the
arbiter, clamp, SAFETY-28 gate, log and MQTT all ran on the real one - a
second controller everywhere except the wire); recording nothing (blanks the
row exactly when arbitrage is trading, and the log's edge key is the watts);
and recording the unsized ask beside it (a second number, no warning, and at
the shipped 3500/2000 both figures read 2000 W).

"UPPER BOUND" AND NOT "SMALLER", AND THE DIFFERENCE WAS MEASURED. Charging
only adds offtake, so the shadow size is >= the live size with EQUALITY at
the start of every quarter. Pairwise over 3600 charging cycles in five
configurations: 0 below, 730 exactly equal. The first draft said "smaller",
which would have been false on every one of those 730.

AND THE PREDICATE IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED. arbitrage's
own sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" only when the
headroom came out below the ask - in a shadow run, the START of the quarter,
where the two runs agree to the float. By the end, 900/remaining has
multiplied the headroom past the ask, the trade is not capped, the sentence
is silent, and the record is at its most wrong. A caveat keyed on it would
be quietest exactly where it is needed loudest.

SAFETY-10 §6's COMMITTED EVIDENCE COULD NEVER HAVE FAILED, FOR TWO
INDEPENDENT REASONS, AND CLOSING EITHER ALONE CLOSES NOTHING. Its fixture is
peak_cap_w 15000 against a 350 W house, so the guard never engages and the
sizing is inert - the harness's own comment says so. AND every identity row
reads the FIRST charging sample, where at elapsed=0 the projection IS the
held level and the two runs agree to the float even at a cap that does bind.
Measured: widening the fixture alone leaves that comparison passing. That
second reason is a new shape for MUTATION.md's habit-4 list - an INDEX, not
a fixture - and it is recorded there as the twelfth instance. §6 is re-taken
at a binding cap across the whole run: 716 of 720 charging cycles differ,
headroom 300.0..54000.0 W in shadow against 299.9..307.8 W live, recorded
-2000.0 W against a live -302.4 W.

THE GRADER IS test_arbitrage.py PART 3d, beside SAFETY-45's own closed-loop
regression and built on the same s45_loop() harness, so the runs differ in
one argument. Three lines stand in for _write_unit()'s substitution and
_shadow_settle()'s record and re-seed, marked as a transcription;
test_clamp.py part 8 remains the check on the shipped placement. The section
carries its own precondition into every check: a mutation that stopped
either run trading made it raise on its first min(), kill the file and
report ZERO reds - FCST-06's shape, driven rather than imagined.

AND THE FIX'S OWN FIRST DRAFT CARRIED THE SAME DEFECT. Deleting the caveat
from the action-log line left all 29 files green, because the sentence was
an f-string inside _shadow_settle() and the only suite that drives it uses a
meter_source:off fixture where no arbitrage decision exists. It is
shadow.log_line() now, for the reason words() is a function.

14 mutations, no survivors; M13 and M14 are +0 B and were confirmed on disk
by sha256 with every run purged. M14's first form was aimed at the wrong
direction and correctly survived - min->max makes the shadow record larger,
which is still an upper bound. All 29 check files green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-15 01:26:57 +02:00
Claude 8fa4febfef SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside
while it was happening, and each was paid for at the meter first: SAFETY-45's
28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong
quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain
310 Wh. There was no way to watch what the optimiser WOULD do without letting
it do it.

`shadow_mode` runs strategies, arbiter, clamps and guards, records the
decision with its reason, and commands nothing.

⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary
single writer. The inverter holds its last command forever - it has no meter
timeout - so "commands nothing" implemented as "stops writing" would leave
whatever was standing when shadow mode came on standing for as long as it was
left on, under a page saying nothing is being commanded. That is the failure
this repository keeps finding. Refreshing 0 W is also what
firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going
quiet would keep that board tripped for the whole run, which is an alarm being
used as a mode.

⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its
own. It is a substitution inside Controller._write_unit() - the single choke
point every write already reaches - in the same form as the three above it,
and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still
grade the number the decision path produced.

⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The
Supervisor composes options as {**config.yaml defaults, **stored user
options}, so a new key with a new default reaches EVERY EXISTING INSTALL on
the next update - including the one regulating a real battery. A boolean
default-on would have stopped it silently. There is no mechanism by which one
key can default differently for a new install and an existing one, so
"default-on for new" is a value the add-on RESOLVES: `auto` is shadow while
control is STOPPED and live once it is STARTED. A fresh install ships
`auto_start: false` and comes up observing; an install that is controlling is
started and does not change by one watt.

THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade
Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision
they would disagree with a meter that never saw it and LATCH A TRIP THAT
SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate
(SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation
(SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch,
because their evidence is measured power. The operator stop is the one
deliberate change: enforced at the wire rather than as a P_SAFETY claim, which
would otherwise make every recorded decision read "stopped".

⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what
stands on the wire, which makes the exit safe by construction - and therefore
the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow
run answers "what would it command now", not "what would it have done next".
The strategies are unaffected; all three defects above are visible from one.

Graded on the writes and on the rendered surface, never on the flag: 22
mutations, no survivors, including one that lets a write escape and one that
goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig,
same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %;
shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage
decision is identical in action, instant, signed power, reason and arbiter
winner.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-14 17:25:43 +02:00
glenn schrooyenandClaude Opus 5 e1b9254626 SAFETY-45: a price-driven charge is SIZED by the capacity guard, not switched by it
checks / unit (pull_request) Successful in 7m42s
With arbitrage armed at the shipped defaults, arbitrage and the capacity-tariff
guard drove each other in a sustained limit cycle. Re-measured on TEST-23 stage
3's closed rig against 478ba93, metrics recomputed rather than taken from the
card: `peak_cap_w` 1500 / 1200 W house -> 28 charge onsets an hour, mean period
131.1 s, the grid swinging -455.5 to +3200.0 W; at the SHIPPED
`peak_cap_w: 3500` with an 1800 W house -> 8/h, with a 3000 W house -> 32/h.
The bite rule is `load + max_w > peak_cap_w`, i.e. any house over 1500 W in the
cheapest quarter. §10.2: "an EMS that oscillates is worse than no EMS, both for
hardware wear and - per §9.1 - for the peak it is trying to avoid." And it was
losing the argument it was having: EVERY billed quarter in the three affected
configurations finished OVER the cap.

⚠️ THE CARD'S STATED MECHANISM IS WRONG AND THE CORRECTION IS ON THE RECORD.
The card, and .cache/s45.md before it, say the loop is the quarter boundary
resetting the projection and arbitrage re-arming at full power. It is not. Of
the 27 gaps between the 28 onsets, 23 are 90-120 s (mean 111.5 s) and lie
ENTIRELY INSIDE one quarter; the four long gaps - 230, 240, 250, 255 s - are
exactly the four that SPAN a boundary, so the boundary LENGTHENS the interval
rather than causing an onset. The real cycle, off the recorded fields: the trade
charges at max_w while `wanted = batt_w + excess` is negative and the guard
files NOTHING; `wanted` crosses zero; the guard engages on a floor of 5.3 W;
that flips `arbitrage.guard_state()`, which cancels the WHOLE trade; the
grid-following loop - which targets grid = 0, not grid = ceiling - takes the
actuator and discharges to +1870 W, exporting 420 W; the projection collapses;
the guard releases; the trade re-arms at max_w. A binary interlock keyed on a
continuous quantity. A fix aimed at the boundary would have removed four of
twenty-eight onsets.

THE FIX IS A SHAPE THIS ADD-ON ALREADY HAD. `control.maintenance_charge_floor()`
caps a MAINTENANCE charge at "the headroom left under the site's cap", because
"a maintenance charge is the only thing this system does that is big enough and
long enough to set that peak". ⚠️ That sentence stopped being true when OPT-04
landed. `peakguard.charge_headroom_w()` publishes the same quantity off the
MEASURED guard rather than off the optional `peak_forecast_entity` - the hole
SAFETY-25 had to close in `shaping_suspended()` - and `arbitrage.decide()` sizes
its BUY leg to it, keyword-only and with no default.

NO NEW ARITHMETIC AND NO NEW CONSTANT. The number is `wanted_w` read in the
other direction: `decide()` already computes the DISCHARGE that lands the
quarter on the ceiling, and a negative one is a permitted CHARGE of `-wanted`.
⚠️ `peakguard.decide()` IS UNCHANGED - sha256(decide) = 200090d0835a3a55, 7252 B
on this branch and on 478ba93 - so 2026-08-20's anti-bang-bang rung is exactly
where it was, and tools/replay_ac3.py reproduces 190/190 guarded quarters, 110
engaged cycles, 5 blind and 878 Wh on both trees.

TWO PROPERTIES MAKE IT SAFE TO HAND A STRATEGY, BOTH SWEPT RATHER THAN ARGUED.
It is INVARIANT IN THE BATTERY - raise the charge by dW, the meter rises by dW,
so `excess` rises by dW while `batt_w` falls by dW and `wanted` does not move:
1350.0 W at every point across batt_w -5000..+2000 W on one banked quarter,
while the `excess` those runs see takes six distinct values. It is feed-forward,
so consuming it adds no feedback path around the plant. And HOLDING IMPLIES ZERO
OR UNKNOWN: across 1080 swept combinations not one ENGAGED decision answers a
positive headroom.

AFTER, same rig, same command. 1500/1200: 28 onsets -> 1, grid swing 3655.5 ->
282.0 W, energy bought 180.0 -> 285.2 Wh (+58%, because a continuous 300 W trade
beats a 2000 W trade cancelled for 57% of the hour), billed quarters
1490/1497/1509 -> 1500.0/1500.0/1500.0. 3500/1800: 8 -> 1, 3511/3536/3559 ->
3500/3500/3500. 3500/3000: 32 -> 1, 3519/3542/3557 -> 3500/3500/3500. The two
shipped-default rows buy 2.2% and 1.6% LESS energy and in exchange the worst
quarter goes from 59 W over the cap to zero - which is the ordering §10.1 asks
for, since the capacity tariff bills the month's single worst quarter.
⚠️ AND THE NEGATIVE CONTROL: at peak_cap_w 5000 with a 1200 W house, where
`load + max_w` never reaches the cap, the two runs are BIT-IDENTICAL.

⚠️ A NEGATIVE `lo` WAS CONSIDERED AND REJECTED, AND THE REASON IS IN THE CODE.
Deleting `decide()`'s `wanted <= 0` gate and filing `lo = wanted` is the tidier
answer arithmetically. It creates a new `lo > hi` CONTRADICTION against
main.py's cheap-window maintenance shaping, which files a NEGATIVE `hi`;
arbiter.py clause 2 has no notion of one limit out-ranking another, so it
resolves to 0 W - the battery PARKED in the quarter that sets the bill - and the
only way to close that suspends the maintenance charge shaping PERMANENTLY on
every site this card is about. A backoff or cooldown in arbitrage was rejected
too: both modules' design notes say no timer is invented, and the trade now
re-arms at `ceiling - load` rather than at max_w, which is what learning from a
refusal means when the refusal is a measurement.

THE REGRESSION IS THE LOOP SETTLING, NOT A UNIT TEST ON decide().
test_arbitrage.py 3c closes the loop over the shipped guard, strategy, arbiter,
control law and QuarterAverager with a modelled plant, and asserts BOTH
directions: unsized it must run away (24 onsets, -414..+3200 W, a quarter over
the cap) and sized it must settle (1 onset, 303 W swing, three quarters at
exactly 1500.0 W). The two runs differ in one argument. A third pair asserts the
card is INERT where the defect is inert.

Evidence: 29/29 green. 14 mutations, every one RED on a named check, no
survivors; two are ZERO BYTES - `min()` -> `max()` on the sizing, and the
sized-trade sentence's two operands transposed - and both are red. M13 reverts
the 2026-08-20 rung and is red on EIGHT named checks in test_peakguard and three
in test_arbitrage. Every revert verified by a tree fingerprint AFTER the revert,
which is how a defect in the battery's own harness was found: two edits to one
file, restored in list order, left the first one on disk (MUTATION.md habit 18).
test_peakguard.py part 1 also gained a None-safe format, because the mutation it
exists to catch made it raise TypeError one line later and ABORT the file -
parts 2-13 were ungraded and M13's recorded coverage was one check instead of
eight.

Not fixed, and named: TEST-23 finding 1's export overshoot at the END of a trade
(356-938 W, ~0.37 x max_w) is a different card; a house whose load ALONE exceeds
the cap still has the trade refused outright and the loop drive to grid = 0
rather than to the ceiling, and no swept pair reaches that regime; the container
leg (hadrive.py) was not re-run because test23s3-addon is deliberately stopped
as a second writer on the setpoint entity.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-14 16:10:34 +02:00
adminandClaude Opus 5 610725bed9 TARIFF-11: the plan's account of itself, corrected and put on the page
Four defects of one shape - the add-on's report of its own tariff plan was
wrong, always in the direction that flattered it - and one check, which is
the deliverable.

1. `TariffPlan.words` counted POINTS and called them HOURS. The live add-on
   logged `dynamic_dayahead from generic_dayahead, 132 h` for 132
   quarter-hourly points = 33 hours. Belgium moved to a 15-minute MTU on
   2025-10-01, so this was wrong every time it was printed, and NOT by a
   constant factor: a 40-hour soak measured 1.79x .. 5.33x, because §8.3's
   carried points are hourly while the firm ones are quarter-hourly.
   `words` now reports both quantities, plus the firm/carried split and the
   spacing, in FCST-04's *Price history* wording so the two rows can be
   compared.

2. §8.3's firm-pair refusal and the flat-tariff refusal did the same, and
   they reach an operator through `self.arb.explain()`. This is exactly the
   point<->hour conflation TARIFF-14 removed from `at()`, left standing in
   the prose. `price_forecast.py`'s §8.3 carry-forward log line carried the
   third instance - a carried-HOUR count over a POINT count - and DOCS
   quotes it verbatim, so it is corrected here too.

3. The plan reached no HTTP surface at all. `rows["Tariff"]` was
   `static_status()`'s 30 s-tick sentence and never saw the provider plan -
   it read 'no static profile' at all 802 soak samples on a site whose feed
   was answering. It now carries the plan's shape. ⚠️ The two sources are
   kept distinguishable: the plan half is stamped with its own age, measured
   from `tariff_at`, because it can be up to TARIFF_MAX_AGE_S (5400 s) old.
   FCST-04 pins that row to DOCS as a pair; DOCS moves in this commit.

4. `main.py`'s "if and only if" was false. `cycle()` returns at the input
   hold before `self.arb = None`, so an armed site read
   `off (arbitrage_enabled)` - naming an option that is on - and, after one
   completed cycle, showed a decision up to 15 s stale as a current one. The
   row now reads the OPTION and separates three facts; `cycle_at` and
   `arb_at` make "this cycle reached no decision" an observation.

THE DELIVERABLE IS THE CHECK. All four survived 29 green suites because
nothing graded the strings a human is shown. `test_price.py` section 12
renders through the shipped `status_payload()`, parses each number out of
its OWN SLOT and compares it against a figure computed from the fixture's
construction parameters - not from the property the row was built out of
(habit 4), and not as a substring of a sentence the same file wrote (habit
14). The fixture set is four plan shapes and the check computes and prints
the field pairs no fixture separates. The *Arbitrage* row's states are
driven through real cycles with a sensor answering None and graded by
INEQUALITY.

No behaviour changed: no threshold, refusal rung, claim or setpoint moved.

MUTATIONS: 16, no survivors, one at +0 B (the risky delta) and red. Two were
found by the battery INSIDE THIS CARD'S OWN CHECK: a -190 B survivor whose
fixture varied two things at once (habit 4), and a mutation whose red was a
TRACEBACK in an f-string operand and therefore named nothing (FCST-06). Both
closed; the table is on the PR.

All 29 test files green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 13:51:05 +02:00
Claude f5ea39784d Merge release/1.0 (TARIFF-10) into TARIFF-12
checks / unit (pull_request) Successful in 7m16s
CHANGELOG.md was the only conflict: both entries belong under the same
`## Unreleased` heading, TARIFF-10's first because it merged first. No
version number picked.

app/main.py auto-merged, and was re-read because of it. TARIFF-10 changed
WHICH installs run `run_tariff_refresh()` (`arbitrage.enabled(opts)` ->
`tariff_refresh_wanted(opts)`); this card changed what that task does on
a failed fetch. Nothing in the keep/replace reasoning changed, and the
two newly reachable configurations are now DRIVEN in test_arbitrage.py
8b rather than reasoned about:

  * a provider configured with trading DISARMED is the case the guard
    was designed for, and needs no second fixture because nothing on
    this path reads `arbitrage_enabled` at all - asserted over the AST's
    symbols and non-docstring constants, after two drafts of that check
    went red on a CORRECT tree for matching the word "arbitrage" in a
    docstring and in a log line;
  * `price_provider: off` + a `static_profile` resolves to the
    CONFIGURED product (`origin: "static"`), so `standing.from_feed` is
    false on every refresh and the guard never latches - driven twice in
    a row, because a guard that latched there would freeze a static
    site's plan at its first window for the life of the install.

Also: the kept-plan log line said "arbitrage stops with it", which after
TARIFF-10 is false on a site that fetches without trading; it now says
"arbitrage, where it is armed, stops with it". The keep decision is
strictly downstream of `resolve_tariff()`, so the §8.3 carry into
price_history - TARIFF-10's whole point - is unaffected either way.

All 29 suites green on the merged tree, including TARIFF-10's new
test_price.py section 13. All eleven mutations RE-DRIVEN on the merged
tree rather than carried over: eleven red, no survivors, every revert
fingerprinted. M11 is new - making the guard conditional on
`arbitrage.enabled(self.o)` (+86 B) is red on five named checks.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-12 21:31:27 +02:00
Claude c81289527f TARIFF-12: a returned degradation is not a refresh
checks / unit (pull_request) Successful in 7m12s
`run_tariff_refresh()` promised in its own docstring that "a failure does
not clear the plan", and enforced it with `except Exception` - a branch a
supplier outage never reaches. `load_prices()` states the reason in its
own words: it "RETURNS, NEVER RAISES, for every failure a site can
actually have", because a degradation arriving as a traceback into the
planning tick would stop the controller regulating over an expired
certificate. So a dead feed RETURNS a §11.4 plan, the `try` succeeds, and
the assignment below it overwrote the good plan unconditionally. With
`static_profile` unset - the shipped default, and the normal state of a
dynamic-tariff site - `_degrade()` returns `TariffPlan(no_data, None,
"none")`: a complete 48-hour plan replaced by nothing, at the FIRST
failed fetch, ~27 minutes after the last good one. `TARIFF_MAX_AGE_S`
(5400 s) never governed anything and there was no serve-stale window at
all.

Fourth card in one family: FCST-04's M4 (`not ok` only), FCST-05's HIGH
(`(JSONDecodeError, OSError)` only), FCST-06 (`not self.ok` only), and
now `except Exception` only, for a path that never raises.

The question is now asked once, after the attempt, from the evidence
that exists - FCST-06's answer, one module over. The evidence is
`TariffPlan.from_feed` (did this resolution observe the configured feed)
and the shipped `fresh_tariff_plan()`, reused rather than transcribed. A
degradation replaces a standing observation only once that observation
has aged out, so `TARIFF_MAX_AGE_S` is now the serve-stale window it
reads like.

A §11.4 static fallback does not replace a fresh provider plan either,
although it carries real prices: every point `_degrade()` builds is
`provisional=True`, so `firm_points()` is empty, `arbitrage()` refuses
and `cheap_now()` is False - everything a consumer may act on is already
off - while a day-ahead price for a given hour does not change once
published. The rule is deliberately not symmetrical: a standing plan
that is itself a degradation IS replaced, or an outage would freeze the
operator's static profile at the window it was first generated for.

`tariff_at` does not move on a kept plan. It is the moment of the fetch
that produced the plan standing, `fresh_tariff_plan()` judges the age
from it, and an unmoved timestamp is the only thing that tells a kept
plan from a freshly fetched one.

test_arbitrage.py section 8b drives the whole chain with nothing stubbed
but the socket: the transport raises the way aiohttp does, load_prices()
returns no_data, _degrade() builds the §11.4 plan, and the shipped
run_tariff_refresh() decides. A check that patched resolve_tariff to
RAISE would have passed against the defect. Ten mutations, ten reds, no
survivors; 29/29 suites green.

Out of scope and unchanged: the persisted price store still does not
back the plan during an outage (FCST-03), and the status banner and the
Arbitrage row's lag are separately carded.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-12 21:06:45 +02:00