02c0a3dd7b90f4382d2e788c9da02bb4aa4c3f8e
111
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
02c0a3dd7b |
MAINT-10: maintenance start hour in local time, default 19:00
The start hour was compared with the UTC hour, so the shipped 10 started at 12:00 in a Belgian summer. It is now read in Home Assistant's time zone (fallback: the container's TZ, then UTC, one log line says which), and the default moves to 19. DST: a missing hour starts at the first hour after the jump; a repeated hour starts only in its first pass. Stored options are not rewritten: a saved 10 now means 10:00 local (DOCS, CHANGELOG). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
516bc8b4ec |
Merge release/1.0 into safety-78-drain-at-two
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
f967073cfe |
SAFETY-81 review: 10 s hold, ERROR line per episode, more scenarios
- The alarm must hold for peakguard.ALARM_HOLD_S (10 s) on the projection's
clock. A load that tops cap + battery for ~5 s every 30 s alarmed at every
quarter start while the quarter landed under the aim (sine4500_fast).
- A cycle with no battery reading leaves the hold alone.
- Notified once per quarter, but the ERROR line is written per episode.
- New sim scenarios (sine4500_fast, twice7000, step6500_gap) with
|
||
|
|
6eb67c0f9c |
SAFETY-81: no false 'Load too high' alarms
The alarm now also needs peakguard.load_too_high(): with the battery at full power, the quarter still ends more than 10 W over the real limit. The battery reading is the lower of this cycle's and the last, so a meter sample from before the battery's last increase is not counted twice. At most one alarm per quarter. Control outputs unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
5d27f8496f |
SAFETY-78: maintenance drain at N=2 no longer stalls
At two inverters the drain pins its pack and the site target is split around the pin. Below the pin the other pack had to charge, the allocator refused the opposite directions, and the site sat at 0 W with an ARBITER line every cycle (house below or above the drain rate, or a grid charge). main.py now files a site limit `drain` (lo = what the pin places, at P_MAINTENANCE) at N>=2 while a pack drains, so the other pack only adds power in the same direction. A drain that cannot give power waits with one log line. With battery modes on, no grid charge while a pack drains, and the other battery's card says why. N=1 is byte-identical. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
6dab4ec16b |
OPT-11 P3, owner option A: selling off, Leftover solar takes solar only
Owner decision 2026-09-29. Selling is off until it can be judged on the price
the grid pays: packmode.SELLING_ENABLED = False makes read() answer
sell=False whatever the store holds, pack_sell is refused ("Selling is off
for now."), and the page has no selling switch; the sell code stays. Until
the P4 forecast, only Cheap hours only charges from the grid
(packmode.GRID_CHARGE_MODES); Leftover solar holds and gives in the
expensive runs. Help, Today and plan lines, DOCS and DECISIONS follow.
Replay, 16 days: Solar first + Leftover solar 19.44 EUR net (P2 19.33).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
|
|
902524ae5e |
OPT-11 P3: price runs per battery
Cheap and expensive hours as runs of consecutive firm price slots
(priceruns.py); each battery's role per tick from its mode (modetrade.py):
grid charging for Leftover solar / Cheap hours only, never Solar first;
holding for the expensive runs; selling per battery (pack_sell) above the
spread and the floor. The site trade is sized inside the modes (loop bound)
and the peak guard's headroom; a run edge reseeds the loop. Cheap hours only
and selling are enabled on the Batteries screen and in the HA select
(appended). The site Why row no longer says "held back" when the peak limit
pushes power up (F2). Modes off: byte-identical to
|
||
|
|
e6096d3e17 |
Merge release/1.0 (7337b79, OPT-11 P2) into safety-79-peak-margin
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c664e38ef4 |
OPT-11 P2 review: refusals stay counted, removals survive a start with no broker
- A refusal past the log-once set or the 32 cap is counted in the log at 1, 10, 100 and so on, so a repeated attack stays visible. - The logged topic is printable only (no forged log lines). - mode_announcement(): the start-up store logic, now tested with a real Store. A removed config topic stays stored, so a start with no broker cannot forget it (rename case tested). - A test ties each HA mode option to the page's English name. - packmode.enabled() is tested for "true", 1 and "false". - Retained-command text, DOCS and DECISIONS updated to match. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
b310282729 |
OPT-11 P2: HA entities for battery modes
Each battery gets an MQTT-discovered Mode select and Use switch, only while
battery_modes_enabled is true. Commands go through handle_action(), the
/action path; refusals are logged once. Retained commands are never applied.
Turning modes off removes exactly the configs announced (kept in the store).
With modes off the announcement is byte-identical to
|
||
|
|
7c4c8f5c66 |
SAFETY-79: peak guard keeps a margin below the limit
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.
peak_margin_w 0 is byte-identical to
|
||
|
|
ffc9a4d721 |
OPT-11 P1 review: a mode never beats the peak floor; SAFETY-03 kept at the rail
- arbiter: a mode now gives way only as far as a site limit above P_MODE
needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
released only when the peak floor bound S, so a trade won above the floor
kept them and placed less than the floor (an Off battery at N=1 went to 0 W
under a 2000 W floor), and a capped grid charge released an Off battery.
While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
(peak floor, trades, maintenance, refusals);
|
||
|
|
d69fd8fbfd |
OPT-11 P1: per-battery mode limits, on/off, solar order
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to
|
||
|
|
667b8e9145 |
UX-13 P5: Dutch text, STYLE check, DOCS screenshots, period editor
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English fallback per key; the page picks by browser language. Home's sentences move into ui_text `home_words`, so /status?lang=nl builds them in Dutch. - test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon lists for both languages, no inline details, untranslated Dutch caught. Shared rules moved unchanged to tools/style_rules.py. - tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot. - "Other time windows": a list editor (ui.periods) that builds static_profile and names bad times, empty prices, overlaps and gaps. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
159d7461d8 |
UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only refusal, the add-on now serves the setup wizard in setup-only mode instead of exiting 78. It builds no controller, MQTT client or meter task, its HomeAssistant is read-only (every service call refuses before sending), Controller refuses a read-only HomeAssistant, and /action answers 409. Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md. Wizard fixes from the UX-13 P4 test: - F1: /config/validate converts what it can, so a conversion error blocks its own step and the live checks still run; save 422 carries steps. - F2: saves send the model the page opened (base); only keys this page changed are written onto the blob stored now. - A meter entity missing from Home Assistant is red on the last step. - Step 1 says the reading went down after a skip that followed a fall. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
06aa09e28c |
SAFETY-73 review: a refusal needs 22 s of evidence, and the cut-out warning is for giving only
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) * LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both units 10-16 times an hour after load steps (site held 0 W). 2 s and slower ticks are unchanged. - REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that stops taking charge is always above its cut-out level. - test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal; the release/1.0 checks are restored and a span check added. - test_refusal_units: lagged-reading and full-battery plants, two new checks, U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
1a9c7523c9 |
Merge release/1.0 (a36dca6) into SAFETY-73-per-unit-refusal
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
f8d63cc614 |
UX-13 P1: page shell and Home screen on a structured /status
- app/static/{index.html,app.css,app.js}: tabs (Home, Batteries, Settings,
Setup), hash routes, phone bottom tabs, light/dark. Served inlined at "/";
the route list is unchanged, and every URL is relative.
- app/homeview.py: /status gains state, now, batteries, plan, attention,
month_peak and control beside the old fields. The plan is what the add-on
does today: the arbitrage verdict (the same plan.arbitrage() call as the
cycle), the monthly cycle, the peak limit, "follows the house".
- The Home plan chart has hover, tap and keyboard-focus tooltips: price bar =
hour and price; block = what, when, why, kWh and EUR.
- Region preset and year: in config/model (for P2) and on the Home price line.
- test_home.py; test_messages part 8 scans every Home sentence; STYLE plan line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
|
||
|
|
016ed5a5a3 |
SAFETY-73: a battery that refuses, per inverter, with two or more
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R). A unit that gives < 100 W for 12 cycles in one direction while asked > 200 W, or trips its stale-reading gate on a ~0 W reading, gets a P_SAFETY `refused` unit limit closing that direction, so the allocator hands its share to the others within their own limits. Probe: a +-200 W pin every 15 min, one unit at a time, only while the site asks 200 W that way. All units refusing: the site law holds 0 W. Exits reseed the site target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above the configured cut-out; SAFETY-42/43 no longer report a refusing unit. N=1 unchanged. test_refusal_units.py: cases a/b/c on flat and jitter registers against the old behaviour, probes, recovery, exits; mutations U1-U13 all red. TEST-19 no-fault campaign: 0 engagements in 5280 runs. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
3c0f2b9669 |
SAFETY-52 review: a refusal is under 100 W, and any delivery ends it
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's own 100 W answer, not below saturation_w: a battery derated to 100-499 W was held at 0 W ~93 % of the time. - A reading of 100 W or more in the held direction ends the refusal, probe or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy reading's lag, and that held a healthy step at 0 W until the next probe. - test_refusal part 5b and a seed test; DOCS states the N>1 limit; the DECISIONS record carries the traced cause of the replay's extra trips. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
1f97c7652f |
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
At the BMS cut-out the saturation freeze held the last request for hours (+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid error changed sign. compute() now carries a refused direction: after SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go on charge, an answered probe, stop/start or another writer. A stale-reading trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's ~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A). test_refusal.py drives the real Controller and gate; tools/replay_refusal.py replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what SAFETY-58/59 must take into account. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
3c298af3d8 |
UX-11 review: restored stops log their figures to events, the quiet-meter WARNING is rate-limited
- After a restart, each restored stop (direction per inverter and site, delivery, circulation) also writes its saved reason to the action log. log_level defaults to info and events starts empty, so the DEBUG evidence alone left the figures only in state.json. - A flapping meter (ha_signed under a flat load, 42-97 s between changes) logs at most one WARNING/INFO pair per 10 minutes, with the episodes in between at DEBUG. - LONG_LINE_OK refuses any key whose text is a safety reason. - test_watchdog keeps the byte pin beside the meaning pin, since the text did not change. - DOCS says the DEBUG line needs log_level debug. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c628099e69 |
UX-11: the meter WARNING names the limit only, as 'over 30 seconds'
TEST-23 showed 'No meter reading for 30 seconds, over the limit of 30 seconds': the age is 30.4 s, which rounds to the limit. The limit alone is always true at the moment the line is logged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
29837dfaa7 |
UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG
- Every WARNING/ERROR line that reported a safety reason (direction, delivery, stuck meter, stale reading, peak guard, circulation, over-rating) now ends in the reason's code (messages.reason_code()). The reason itself, figures and limits included, is on a DEBUG line right after it and in the action log. - The reasons and state.json are unchanged, so an old state file loads and shows the same way: every saved reason opens with its code. - test_messages part 6 checks every WARNING+ line at 25 words as logged; nine non-safety families are listed with a reason and capped. The byte pin in test_watchdog now pins the meaning, in order. - The meter logs one WARNING per quiet episode, and INFO when back, so the red row's "the add-on log shows why" holds. The Why line past the hold names the missing reading. Action log: "25 engagements", "Shadow mode off: ...". No trigger, latch, threshold, log level, notification id, cadence, row colour or banner order changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
e0b578756f |
UX-10 review: the line as logged gets the red-alarm shape, clamp lines at 30 words, plain HA 400
Part 6 checked the quoted reason alone, so title + reason + tails logged as 4+ sentences. It now also checks the whole line (at most 3 sentences, none over 30 words); 25 lines failed and are rewritten (one-sentence wrappers, two-sentence circulation and peak reasons, STALE_READING's fixed limits on a DEBUG line). The clamp lines for one inverter are pinned at 30 words with OUTPUT_CLAMP and the numbers kept. Home Assistant's bare '400: Bad Request' while it loads becomes one plain line; still WARNING, throttled, a failed write. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
23a3a3f5b5 |
UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified as data or as a built text, and every built text is produced by the real code and checked. This is the gap the 2d scan had: it counted `%s` as one word, so reasons built by loop_clamp_note() and friends were never seen. - Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept): OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak guard (codes now PEAK_GUARD*), the migration report, price feed, price history and gate reasons. Plurals via messages.times()/count(). - Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff "one every 15 minutes or every hour", "not final yet" dropped. - Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO, aiohttp access log only at log level debug, settings warnings once per start, one plain line per Home Assistant outage (hass.Outage). - INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE", "NOT_OBSERVED", "did NOT land", "AND". - Display bugs: WHY_WINNER covers every winner and safety reason (main.why_key(), part 7 finds them in the code); the meter row is amber "waiting for the first reading" inside its limit after a start; the missing-reading age is counted when the page asks. - STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section). No change to safety behaviour, alarm levels, notification ids, triggers, cadence or the banner cascade. One row colour changes (meter at start), justified in DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
569f16aa91 |
UX-08 2d review: action log reachable in status JSON, engaged peak row pinned, imported keys expanded
- status_payload() also returns the action log as `events`. The page does not render it. Some entries (a dropped inverter's reason, the peak guard's projection, unplaced watts) are written nowhere else, and DOCS still points installers at the action log. - test_peakguard pins the engaged row's ordered pair (the battery's share, then the limit). - test_messages expands setting keys named by constants imported from another app module, so the shown-text 30-word scan counts them. - p1.py: 'A meter message could not be read'. DOCS glossary: control board in plain words, with the hardware in an installer note. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
6a95447248 |
UX-08 2d: plain log lines, the rest of the status page, and DOCS
Every WARNING and ERROR line is one plain line of at most 25 words, with no card ids, capitals or semicolons; the reasoning of the ten longest is on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0). The status page: the month-peak and peak-guard rows, the stale-reading row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the Stopped banner and the line under the buttons, which now shows the plain hint of each event instead of the raw action log. The Supervisor question at start logs one line with a real reason. Refusals are counted as shown (labels expanded, long cases driven), seven were shortened, the card and parse errors lost their internals, a blank value reads "empty", and the panel no longer files inverters.max_w under the flat max_w. Option names lose "(JSON)", the NL texts are checked too. DOCS gets a glossary (control board, isolator, Developer Tools) and card ids move from headings to a "For installers" line. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
63dee6db1e |
UX-09 review: short start-up timeout, latch rows pinned in shadow, plainer rows
The Supervisor questions for the Details link are asked together with a 3 s budget instead of one after the other at 10 s each, so a hung Supervisor cannot hold control start for 20 s. In shadow mode the circulating and site-direction latches are pinned to keep their own red row that says how they clear. Plainer inverter and battery wording. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
00e3ee9de8 |
UX-09: Details link for current HA, "would" in shadow mode, plain terms
- Details link: /config/app/<slug>/documentation on HA 2026.2+ (the old /hassio/addon path is a 404 from 2026.5), /hassio/addon on 2026.1 and older. Slug from GET /addons/self/info, version from GET /info, hostname as fallback. - Shadow mode: the over-rating alarm and row say what would have been sent, the peak alarm no longer says the battery is giving all it can. - "controller" -> "the add-on" / "control". Settings named by their labels; four labels changed to match (Peak reserve, Battery level entity, Solar production ..., Reversed-sign solar entities). - Shadow banner and inverter link notes moved to messages.py and checked. - DOCS Notifications and Status page rewritten for home owners, with a "For installers" part each. Allowlist 168 -> 167. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
571b884315 |
UX-08 phase 2b review: keep over-rating evidence, pin latch clearing, plainer rows
- During a bound episode an earlier over-rating count stays on the page (amber, under its own title); test_clamp pins it. - test_messages pins that every latch row says how it clears. - pv_entities description no longer claims the page names the entity (en, nl); allowlist hash updated for that option-desc line. - Plainer texts: multi-inverter direction banner, "fine now" after an episode, and the e-stop, peak-forecast and peak-guard-waiting rows move to messages.py. - TEL-12 DECISIONS points to UX-08 item 3 for the retired row rule. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
d017fc67bf |
UX-08 phase 2b: short, plain status rows and page banners
Every Commissioning row and every page banner is now worded in app/messages.py (row_*, banner_*): one sentence of at most 15 words, a red row up to three sentences so a latch still says how it clears, banners at most 12 words. No row names a Home Assistant entity: sensors by their setting, solar sources by their place in the list. Reason codes and limits stay on the log line and event list; rows keep the numbers a reader acts on. UX-07 item 1: ClampWatchdog counts over-rating and integrator-bound engagements separately, and after an episode each count shows under its own alarm's title instead of both under "output clamp". No row colour, visibility or banner order changed. Rows carry an "id" so the tests pin meaning rather than wording. The row and banner kinds leave the allowlist (200 -> 168, cap equal). DOCS.md gains "Status page"; choices are in DECISIONS/UX-08-short-notifications.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
7b65a3e69a |
UX-08 review: tighter notification texts, and two meaning fixes
- not delivering: the body said control keeps running and then "start
control"; clearing it takes stop then start, and it now says so.
- peak reserve: the "reserve not set" branch is really soc_floor None,
i.e. an inverter's cut-out level missing; it now names that. The title
is true on all three branches ("Battery stopped limiting the peak").
- no semicolon run-ons in bodies (STYLE.md + test); loop-bound, circulating,
meter-frozen and multi-unit over-rating bodies rewritten to match.
- allowlist cap is now exact, so a shrink cannot leave room to regrow.
- DOCS names the settings behind "peak reserve" and "cut-out level";
DECISIONS no longer states the HA anchor behaviour as fact.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
|
|
50ccea3dd7 |
UX-08 phase 2a: short, plain notifications, and a ratchet for the rest
Every HA notification the add-on raises now has a title of at most 5 everyday words and a one-sentence body; a red alarm may use three so no action is lost. The texts live in app/messages.py, the rule in STYLE.md, and the detail that moved out in DOCS.md "Notifications", which each body links to. No notification_id, trigger or cadence changed. test_messages.py enforces the rule on every notification, fails any notification worded outside app/messages.py, and ratchets the kinds not yet rewritten (rows, banners, refusals, logs, options) through a shrinking allowlist of 200. Six tests re-pinned from prose to meaning. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
55a6d5dcdb |
SAFETY-40 review: integrator-bound WARNING gets its own notification id
A later anti-windup notice could replace a write-path BUG SIGNAL notice
under the shared goodwe_output_clamp id (escalation ignores the budget).
The WARNING now uses goodwe_integrator_bound and points to DOCS; the
cadence sentence in DOCS is corrected. Tests pin both ids (red on
|
||
|
|
fd14569a71 |
SAFETY-40: the integrator bound is not a BUG SIGNAL; numbers from the clamp tick
The clamp alarm gave `i_clamped` (normal anti-windup) the over-rating BUG SIGNAL text, printed `Decision.i_w` as "the loop asked for", and printed `self.target` (after slew/freeze) as "was clamped to". - clamp.loop_clamp_note(): i_clamped says "the loop's integrator reached its N W anti-windup bound" with this tick's command; clamped keeps BUG SIGNAL with the requested command and the clamp's own result. - Decision carries i_bound_w / requested_w / clamped_w, set at the clamp. - i_clamped still counts and notifies (same id, cadence, SAFETY-41 escalation) but as a WARNING, amber row, plain title. A bug has its own notification budget and its text is not overwritten within an episode. - test_clamp.py part 9: red on the old code per defect; 5 mutations killed. - DOCS.md alarm section (and its stale 30 s cadence), DECISIONS/SAFETY-40. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
6028e21298 |
SAFETY-34: re-assert latched alarms, because a Core restart keeps the add-on
A Core-only restart wipes persistent_notification and does NOT restart the add-on (measured on TEST-23: the add-on's SAFETY-31 card was gone 4 min after `docker restart test23-ha`, add-on StartedAt unchanged). The latched SAFETY-31 and SAFETY-42 cards were re-raised only on add-on start, so they stayed gone. They are now re-asserted every REANNOUNCE_S = 300 s while tripped (same notification_id, so it replaces). test_watchdog part 6 and test_delivery part 8b grade it with the same process across the "restart"; red on the old code. The docstrings that said the add-on restarts with HA are corrected. Record: goodwe docs/DECISIONS.md, SAFETY-34 D4. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
7559d21eda |
TEL-14: PV sign declared per entity (pv_invert_entities)
checks / unit (pull_request) Successful in 8m39s
Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive for consumption and negative for production. `pv_invert_entities` lists the ones to flip; the flip is applied per member inside pv.total(), before the sum, so the MQTT `pv` row and the status page carry the corrected figure. Default [] is byte-identical to 0.12.0. Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0): a parallel list validates the 0.12.0 blob unchanged and renders as its own translated repeatable field; dicts on pv_entities refuse 0.12.0's stored strings; a prefix is invisible syntax; a global bool cannot describe a mixed roster. Status page marks flipped entities and cautions per entity below -50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged. Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
71d2d4a37a |
SAFETY-61: the control task's death ends the process, after the wind-down
checks / unit (pull_request) Successful in 8m22s
A done-callback on run_control()'s task logs the traceback at the death and sets `stop`; amain() runs the ordinary wind-down (shutdown() -> command_site_zero()) and main() exits 70 (EX_SOFTWARE). Normal stops and run_control()'s refusal path are ignored by the callback (still 0 / 78). hass.py: a malformed JSON body, a JSON non-object, and an undecodable error body are an absence / a failed write, not an exception into the loop. checks() gains a first "control loop" row, red past FIRMWARE_INGEST_VETO_S. Why exit rather than restart in-process, and what the Supervisor actually does on exit (restarts only with the per-install Watchdog toggle on, default off): DECISIONS/SAFETY-61-control-task-death.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
0ef9565071 |
TEL-12: several PV inverters, and one absent member is an absent TOTAL
checks / unit (pull_request) Successful in 7m59s
0.11.0 shipped `pv_entity` as a single string. The reference site's owner reported within minutes of it going live that they have several PV inverters and could configure one - which is ordinary for a multi-string roof, not a property of one house. `pv_entities` is the roster and the row carries the SITE total. ⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`, and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no irradiance" conclusion the channel exists to TEST. So `pv.total()` answers `None` the moment any configured entity is absent: the topic carries HA's own `None`, the entity goes to `unknown`, the recorder records a GAP. The alternative (the partial sum beside a contributor count) was implemented and run as mutation N1b; it loses because the MQTT row is read COLD a week later by an attribution that would believe it, while the qualifying count would live in a second entity with its own history. The partial information is not thrown away - the STATUS PAGE names every entity that reported, with its watts, and every one that did not, with its reason, because that surface is read LIVE by a human who wants the diagnostic. ⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is `is None`, never falsiness - a roster that blanked the site on a zero would report an absence on every clear evening. THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list: tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an 0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and deepmerge's list strategy is `override` so a `[]` default does not rescue it - the live add-on would not start. `match(.*)?` does accept both shapes and is rejected for a different, measured reason: it validates nothing (a string, a list and the integer 417 all pass) and renders as a plain text box. So `pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for `inverters:`, with a status caution saying which key won - a union would double-count the inverter the old key still names. STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than replaced and now grades five claims over three document sets. The control hash is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the roster control document is byte-identical between the two trees. 2/5 is a claim TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly as 0.11.0 does" is a real cross-tree identity over control AND telemetry. ⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit 24: a discriminator defined as "the baseline lacks this feature" dies on the release that ships the feature, and dies as a false refusal. Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B (`sum` -> `max`, the same three characters) and was run on a fresh copy with `cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO contributions in two units with absence driven at EVERY position - a member contributing 0 W could go absent without moving the sum of the rest, which is habit 23 with a coinciding value in the arithmetic rather than in the plant. 31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0, so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG entry is wanted and deliberately not written - 11b forbids `## Unreleased` and the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the material it needs. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
07ba3433ed |
TEL-11: PV production stops being invisible, and stays out of the control law
checks / unit (pull_request) Successful in 8m6s
OPT-10 measured that this site's pack reaches 90 % SoC on 2 days of 16 and that
20.5 kWh of surplus left the site while the pack had room - 12.6 kWh of it with
the battery not charging at all - and could not say WHY, because PV production
is recorded NOWHERE. Three causes need three different fixes (no irradiance:
nothing to fix; a charge-power limit; the optimiser declining to charge, which
is the only software defect) and guessing between them is how an optimiser gets
tuned to solve a cloud problem. This card adds the channel. It does not do the
attribution.
AN HA ENTITY, NOT A REGISTER, AND THAT IS A PRODUCT DECISION. This add-on's
RS485 bus carries the BATTERY inverter it drives; a household's PV inverter is
normally a different box from a different vendor reporting into Home Assistant
through its own integration. `pv_entity` takes whatever `sensor.*` the site's
own PV integration provides, any brand HA can read.
POSITIVE IS PRODUCTION, AND THERE IS NO `pv_invert`. The convention is derived
rather than assumed: `meter_entity` is positive when IMPORTING and `batt_entity`
is positive when DISCHARGING (DOCS.md, Sources), both of which are "power
arriving at the house's AC bus", and production arrives there too. Those two
keys carry invert flags because they are BIPOLAR and are READ BY THE CONTROL
PATH - `inv.batt` feeds SAFETY-30's per-unit sign check and SAFETY-31's
circulating-power sensor, so a reversed sensor hands the site a plausible number
it acts on. Production is unipolar and is read by nothing: a reversed sensor
announces itself as -4 kW at noon in the very history this card creates, and a
flag would only let an installer hide it. No negative-value alarm either - a PV
inverter's own standby draw makes a small negative reading at night ordinary, so
any threshold would be a number nobody measured.
ABSENCE IS NEVER ZERO, AND "DROPPED" IS NOT ABSENT. `publish()` SKIPS a None,
which is right for `circulation` and exactly wrong here: a skipped row leaves
Home Assistant holding the last number forever and the recorder draws a FLAT
LINE through the outage, which is indistinguishable from a measurement and
manufactures the "there was no surplus" conclusion this card exists to TEST. So
the absence is published, with HA's own payload: `mqtt/const.py` declares
`PAYLOAD_NONE = "None"` and `mqtt/sensor.py` tests it BEFORE the numeric branch,
so the entity's state becomes `unknown` and the recorder stores a GAP. Read out
of home-assistant/core `dev` on 2026-09-24 and quoted at the constant.
`ABSENT_AS_UNKNOWN` is a one-key set and the suite asserts `circulation: None`
is STILL dropped.
THE UNIT IS READ OFF THE ENTITY. `mW`, `W`, `kW`, `MW`, `GW`, `TW` - HA's own
`UnitOfPower`, every factor an exact power of ten. A sensor with no unit, or a
unit outside that table, is REFUSED by name and the status page says which.
`read_inputs()`'s `abs(raw) < 50` kW-or-W guess is safe for a quarter-hour
demand forecast and is NOT safe here: 30 W of dusk is an ordinary reading and
that heuristic would publish it as 30 kW.
GENUINELY OPTIONAL, AND NOT A SECOND `price_now_entity`. validate.py does not
mention the key - it cannot conflict with anything, because nothing else reads
it. The MQTT row lives in a new `OPTIONAL_SENSORS` list whose `include` argument
DEFAULTS TO EMPTY, so every caller that has never heard of `pv_entity` -
test_mqtt.py's fixtures, tools/rehearse_roster.py, anything written next year -
announces exactly what it announced before. Unset: no state call at all, no
entity, no topic, no status row, no page row. Set and failing: a CAUTION
(`ok=False, warn=True`), never a `bad` row, so a telemetry channel can never put
a battery site into NOT READY.
IT MUST NOT BECOME A CONTROL INPUT, AND THAT IS GRADED TWICE. `test_pv.py`
part 6 drives 40 cycles of the real `cycle()` and asserts the commands are
bit-identical across unset / no reading / 0 W / 8 kW, with a COMPUTED census
(33 modules under app/) showing the material is mentioned in exactly three:
pv.py, main.py, mqtt.py. `tools/tel11_pv_trace.py` is the cross-tree half -
`safety56_behaviour_trace.py`'s pattern with a DIFFERENT control clause, because
this card's claim is that nothing differs rather than that only sentences do: it
REFUSES unless the two `app/` fingerprints differ and unless exactly one side
reacts to the option. Measured on 41 stimulus cells:
control release/1.0 unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
control TEL-11 unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
control TEL-11 set 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
telemetry release/1.0 unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
telemetry TEL-11 unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
telemetry TEL-11 set 4e6d1cb289a957223ad0205f732a6fec6110ce1f2032c98ad60694e67625274f
UNSET is byte-identical in BOTH documents, which is stronger than "the control
path is untouched": an install that does not set the option sees no change of
any kind, announcement and status rows included.
⚠️ AND THE CARD'S CENTRAL MUTATION WAS A SURVIVOR ON THE FIRST BATTERY.
`self.grid -= self.pv_w` in `read_inputs()` - +106 B, on disk, purged, genuinely
running - came back GREEN, because the fixture drove a 6 kW export over 12
cycles, which puts the loop AGAINST ITS RAIL: a command moving `slew_w` every
cycle produces the same ramp for -6000 W and for -14 000 W of apparent error.
MUTATION.md habit 23 with a saturated ACTUATOR in place of a coinciding value,
and it is in that file now as the habit's second instance. The fixture now
drives a 600 W import the loop SETTLES on, against a responsive meter, and asks
habit 23's own question as its own check: shift the METER by the same 8 kW and
confirm the commands really would have moved.
Evidence: 31/31 suites green in the CI image, checks.yml's exact command, purged
tree, `:ro`. Ten mutations, NO survivors, each on its own `cp -a` of the tree so
habit 18's revert hazard is closed by construction - table in
`DECISIONS/TEL-11-pv-production.md` §7 with byte deltas and sha256s.
⚠️ THIS IS A RUNTIME CHANGE BEHIND AN UNCHANGED VERSION, AND
`tools/predeploy_check.py` WILL REFUSE IT. `app/`, `config.yaml` and
`translations/` are all in its `RUNTIME` tuple and `config.yaml` still reads
0.10.1, so the gate reports a NO-OP deploy until a version is cut. That is PKG's
call and this card does not take it.
No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading
that is not config.yaml's `version:`, and opening one would mean taking that
same packaging decision. The operator account is in DOCS.md.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
8a6acd9fa2 |
SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can
checks / unit (pull_request) Successful in 8m0s
Text only. No behaviour change - same conjunction, same limits, same MISSING, same 0 W, same NOT READY. `tools/safety56_behaviour_trace.py` says so: 2390 capture reads, a 66-cell swept grid, and six driven controller worlds produce the byte-identical document `6030175e...` on origin/release/1.0 and on this branch, while the sentences differ. THE DEFECT. SAFETY-37's conjunction is satisfied by two disjoint worlds - the register has stopped reporting reality, or the SOURCE cannot comply with the command - and nothing `freshness.py` is handed separates them. Three sentences asserted the first. On the live 2026-09-21 episode it was the second: the pack read 11 % for the whole 850 s hold, every command in that hold was a discharge, and the register answered the first CHARGE command three seconds later. The readiness row was worse still, because it asserted a false fact about a NAMED entity that was present, numeric and updating - so the operator opened Developer Tools, found it working, and had every reason to conclude the diagnostics were broken. THE FIX. Each message states what was OBSERVED and names BOTH explanations. Three wordings, no shared helper: two are a log line about a behaviour, the third is a banner about an entity, and a helper serving both would drop whichever half the other caller does not need. SoC stays STATED, NOT WIRED - part 11b drives the two worlds at 50 % and 11 % and the sentence does not move one byte. The row does not branch on `batt_fresh.stale` either: `stale_note()` already rides `liveness_notes()` a few rows below, so the discriminator is "is that row there?", and part 11d asserts it is present in one world and absent in the other. THE CHECKS. test_freshness.py part 11 builds the pair of worlds with ground truth written down rather than derived from the published stream, asserts they are really two (40 of 40 reads differ) while the published stream is bit-identical, and only then grades the sentences. Eleven mutations, all red: each of the three sentences reverted (3, 2 and 2 named reds), the two explanations transposed at ZERO bytes (1), the second explanation deleted (1), the admission of ambiguity replaced by a ranking (1), all three reverted at once (5), and two aimed at this card's own check - collapsing the world pair (2) and emptying the accusation list, which a positive control against the three sentences as 0.10.1 shipped them catches (1). AND TWO OF THE ELEVEN FOUND DEFECTS IN THE CHECK RATHER THAN IN THE CODE. Transposing `label` and `entity` in the row made it unfindable and the run died on an IndexError - a red with no name and every later check ungraded, FCST-06's shape exactly; `_s56_row()` returns a named absence now, 0 named reds before, 3 after. And the first invariance run compared a tree with itself, because it archived a branch whose edits were not committed yet; the tool now REFUSES to report "behaviour unchanged" unless the sentences halves differ, and both of its refusals are driven. SAFETY-57's part 10h check was the handoff and is inverted rather than deleted: it required the accusation to still be present so that removing it had to be a deliberate act. This is that act. Its escape clause is untouched. Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
43c144b8d9 |
SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.
REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:
10:51:24.7 0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
10:51:29.7 the command reaches +1060 W - 800 W of travel
10:52:00 the conjunction arms. Inverter.batt becomes None
10:52:21.7 the site commands 0 W, on the wire
... 0x0518 does not change value for 850.0 s. The setpoint does not
change value for 790.0 s. The house exports 2.4 kW throughout
~11:04 a human restarts the add-on. That is what ends it
AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.
THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.
THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:
the verdict is withdrawn when the obligation that produced it has been gone
for RELEASE_S, and the register is then re-graded from scratch.
RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.
The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.
WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.
Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.
main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.
Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.
Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
b548525d10 |
TEL-10: the loop's integrator stops being invisible
`self.i_w` has been a separate quantity from the command since SAFETY-04 and has left the process nowhere at all - no entity, no MQTT attribute, no log line. The investigation behind SAFETY-48 could only RECONSTRUCT it from the grid trace plus a replay; the reconstruction reproduced about a third of the engagements it was checked against and was discarded, so the card it was gathered for had to be argued from a measurement nobody could stand behind. It could not have been made to work either: `i_w` depends on every cycle before it, including the ones where the arbiter overrode the loop and `main.py` re-seeded `self.i_w = self.target`, and that re-seed is invisible in the grid trace. THREE SITE ROWS, APPENDED AFTER release/1.0's EIGHT. `loop_i` is `Decision.i_w` - the accumulator after the cycle, before the output clamp, the slew limit and quantisation. `loop_lead` is `decision.i_w - prev_w` against the command `compute()` was HANDED, which is not a subtraction of the other two published rows: `Setpoint` is the arbiter's output and is this cycle's, so on any cycle the arbiter overrode the loop the two differ - and that is exactly the cycle on which the integrator was re-seeded. `loop_reason` is `compute()`'s own word; the arbiter's `explain()` prints the winning claim's NAME and has never carried the claim's reason, so `slew-limited` appears in neither the `Why` row nor `Controller status`. Measured on the same cycle: arbiter `'loop -> -5000 W'`, loop `'i-clamped'`. NOTHING IN THE CONTROL PATH MOVED. `app/control.py` is not in this diff. `compute()`, its returned `Decision` and every constant it reads are identical to release/1.0, and all nine of release/1.0's retained discovery messages are byte-identical and still FIRST in the announcement. Evidence: 30/30 suites green in the CI image. Nine mutations, ONE survivor, reported as one: `decision.i_w - self.target` for the lead is +2 B and green because `cycle()` has not reassigned `self.target` at that line - the name is kept for the coupling, not for a behaviour it buys, and M2b (+8 B) is the mutation that does change the value and is red. AND TWO OF THIS CARD'S OWN CHECKS COULD NOT REACH THE FAILURE THEY NAMED. "the published integrator reaches its bound" was GREEN under the card's named mutation (publish `prev_w`, -3 B), because the command reaches the bound too - twelve cycles later. It asserts the LEAD TIME now and is red on 5. "a stopped controller publishes not-running" was GREEN under deleting that branch's assignments (-45 B, -67 B), because the fixture STARTED stopped and `__init__` writes the same values; it stops the controller part-way through a run that has already wound the integrator to -5000 W. Both are MUTATION.md habit 4, found by the battery rather than by review. No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading that is not config.yaml's `version:`, and opening one would mean taking a packaging decision this card does not get to take. The operator account is in DOCS.md and the release note belongs to the next PKG ticket. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e3ccd9f6ea |
SAFETY-47: what a shadow run can show, and the watts on its status row
checks / unit (pull_request) Successful in 7m48s
Not a leak and not a write-path defect. Shadow mode's safety is intact -
the substitution, the re-seed, the authorisation gate and the clamp are
untouched. What was wrong is what three merged documents SAY a shadow run
can show you, and a number on the status row that can be 6.61x what a live
controller would command.
SHADOW MODE CANNOT SURFACE A CLOSED-LOOP DEFECT, AND THE DOCUMENTS NOW SAY
SO. The battery is held at 0 W and the carried command is re-seeded to it,
so every measured input - the meter, the billed-quarter accumulator behind
it, the battery power, the SoC - describes a plant that did not respond. A
closed-loop defect is one whose stimulus IS that response. This is the same
property that makes shadow mode safe, so it is not a gap to close later:
the closed-loop answer comes from the closed-loop rig or from a live run.
SAFETY-10 §5 already conceded this for the grid-following loop. It was
never the loop leg's limitation; it is the general case.
THE "STRATEGIES ARE UNAFFECTED" EXEMPTION WAS TRUE UNTIL SAFETY-45 MERGED,
ONE COMMIT EARLIER. That card sizes the buy leg as min(asked, headroom)
with headroom = (900/remaining) x (ceiling - projected), and `projected`
reads the open quarter's accumulator - the meter - which is a function of
what the battery did earlier in that quarter. Measured on TEST-23 stage 3
at peak_cap_w 1500 / house 1200 / max_w 2000, one hour at 5 s:
SAFETY-45's limit cycle NOT visible. 28 onsets live vs 1; grid
-455.5..+3200.0 W vs flat at the 1200 W house;
guard engaged 410/720 cycles vs 0/720.
SAFETY-46's SoC churn NOT visible. The SoC moves 0.000000000 pp.
TARIFF-14's wrong hour VISIBLE, and it is the only one: which hour, at
what price, clearing what spread - identical on
720 of 720 charging cycles at a binding cap.
The exemption narrows to exactly what survives: WHICH hour a strategy picks
and WHY are unaffected; HOW HARD it trades is not. The peak guard's ceiling
and reasons are worth reading from a shadow run; its ENGAGEMENTS are not.
THE NUMBER IS CAVEATED, NOT RE-COMPUTED, AND THAT IS THE DECISION. The
arithmetic is not wrong - 900/remaining is correct for a meter genuinely
under the ceiling, and in shadow the meter genuinely is. It is the right
answer to a question nobody asked. Both surfaces now introduce the watts as
what would have been commanded ON THIS CYCLE, in every state, and carry
shadow.SIZED_FROM_METER whenever a measured billed quarter sized them.
Rejected, and recorded in the decision doc: re-computing it (the recorded
decision would no longer be the decision the shipped path reached, while the
arbiter, clamp, SAFETY-28 gate, log and MQTT all ran on the real one - a
second controller everywhere except the wire); recording nothing (blanks the
row exactly when arbitrage is trading, and the log's edge key is the watts);
and recording the unsized ask beside it (a second number, no warning, and at
the shipped 3500/2000 both figures read 2000 W).
"UPPER BOUND" AND NOT "SMALLER", AND THE DIFFERENCE WAS MEASURED. Charging
only adds offtake, so the shadow size is >= the live size with EQUALITY at
the start of every quarter. Pairwise over 3600 charging cycles in five
configurations: 0 below, 730 exactly equal. The first draft said "smaller",
which would have been false on every one of those 730.
AND THE PREDICATE IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED. arbitrage's
own sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" only when the
headroom came out below the ask - in a shadow run, the START of the quarter,
where the two runs agree to the float. By the end, 900/remaining has
multiplied the headroom past the ask, the trade is not capped, the sentence
is silent, and the record is at its most wrong. A caveat keyed on it would
be quietest exactly where it is needed loudest.
SAFETY-10 §6's COMMITTED EVIDENCE COULD NEVER HAVE FAILED, FOR TWO
INDEPENDENT REASONS, AND CLOSING EITHER ALONE CLOSES NOTHING. Its fixture is
peak_cap_w 15000 against a 350 W house, so the guard never engages and the
sizing is inert - the harness's own comment says so. AND every identity row
reads the FIRST charging sample, where at elapsed=0 the projection IS the
held level and the two runs agree to the float even at a cap that does bind.
Measured: widening the fixture alone leaves that comparison passing. That
second reason is a new shape for MUTATION.md's habit-4 list - an INDEX, not
a fixture - and it is recorded there as the twelfth instance. §6 is re-taken
at a binding cap across the whole run: 716 of 720 charging cycles differ,
headroom 300.0..54000.0 W in shadow against 299.9..307.8 W live, recorded
-2000.0 W against a live -302.4 W.
THE GRADER IS test_arbitrage.py PART 3d, beside SAFETY-45's own closed-loop
regression and built on the same s45_loop() harness, so the runs differ in
one argument. Three lines stand in for _write_unit()'s substitution and
_shadow_settle()'s record and re-seed, marked as a transcription;
test_clamp.py part 8 remains the check on the shipped placement. The section
carries its own precondition into every check: a mutation that stopped
either run trading made it raise on its first min(), kill the file and
report ZERO reds - FCST-06's shape, driven rather than imagined.
AND THE FIX'S OWN FIRST DRAFT CARRIED THE SAME DEFECT. Deleting the caveat
from the action-log line left all 29 files green, because the sentence was
an f-string inside _shadow_settle() and the only suite that drives it uses a
meter_source:off fixture where no arbitrage decision exists. It is
shadow.log_line() now, for the reason words() is a function.
14 mutations, no survivors; M13 and M14 are +0 B and were confirmed on disk
by sha256 with every run purged. M14's first form was aimed at the wrong
direction and correctly survived - min->max makes the shadow record larger,
which is still an upper bound. All 29 check files green.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
8fa4febfef |
SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside while it was happening, and each was paid for at the meter first: SAFETY-45's 28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain 310 Wh. There was no way to watch what the optimiser WOULD do without letting it do it. `shadow_mode` runs strategies, arbiter, clamps and guards, records the decision with its reason, and commands nothing. ⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary single writer. The inverter holds its last command forever - it has no meter timeout - so "commands nothing" implemented as "stops writing" would leave whatever was standing when shadow mode came on standing for as long as it was left on, under a page saying nothing is being commanded. That is the failure this repository keeps finding. Refreshing 0 W is also what firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going quiet would keep that board tripped for the whole run, which is an alarm being used as a mode. ⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its own. It is a substitution inside Controller._write_unit() - the single choke point every write already reaches - in the same form as the three above it, and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still grade the number the decision path produced. ⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The Supervisor composes options as {**config.yaml defaults, **stored user options}, so a new key with a new default reaches EVERY EXISTING INSTALL on the next update - including the one regulating a real battery. A boolean default-on would have stopped it silently. There is no mechanism by which one key can default differently for a new install and an existing one, so "default-on for new" is a value the add-on RESOLVES: `auto` is shadow while control is STOPPED and live once it is STARTED. A fresh install ships `auto_start: false` and comes up observing; an install that is controlling is started and does not change by one watt. THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision they would disagree with a meter that never saw it and LATCH A TRIP THAT SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate (SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation (SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch, because their evidence is measured power. The operator stop is the one deliberate change: enforced at the wire rather than as a P_SAFETY claim, which would otherwise make every recorded decision read "stopped". ⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what stands on the wire, which makes the exit safe by construction - and therefore the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow run answers "what would it command now", not "what would it have done next". The strategies are unaffected; all three defects above are visible from one. Graded on the writes and on the rendered surface, never on the flag: 22 mutations, no survivors, including one that lets a write escape and one that goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig, same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %; shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage decision is identical in action, instant, signed power, reason and arbiter winner. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e1b9254626 |
SAFETY-45: a price-driven charge is SIZED by the capacity guard, not switched by it
checks / unit (pull_request) Successful in 7m42s
With arbitrage armed at the shipped defaults, arbitrage and the capacity-tariff guard drove each other in a sustained limit cycle. Re-measured on TEST-23 stage 3's closed rig against |
||
|
|
610725bed9 |
TARIFF-11: the plan's account of itself, corrected and put on the page
Four defects of one shape - the add-on's report of its own tariff plan was wrong, always in the direction that flattered it - and one check, which is the deliverable. 1. `TariffPlan.words` counted POINTS and called them HOURS. The live add-on logged `dynamic_dayahead from generic_dayahead, 132 h` for 132 quarter-hourly points = 33 hours. Belgium moved to a 15-minute MTU on 2025-10-01, so this was wrong every time it was printed, and NOT by a constant factor: a 40-hour soak measured 1.79x .. 5.33x, because §8.3's carried points are hourly while the firm ones are quarter-hourly. `words` now reports both quantities, plus the firm/carried split and the spacing, in FCST-04's *Price history* wording so the two rows can be compared. 2. §8.3's firm-pair refusal and the flat-tariff refusal did the same, and they reach an operator through `self.arb.explain()`. This is exactly the point<->hour conflation TARIFF-14 removed from `at()`, left standing in the prose. `price_forecast.py`'s §8.3 carry-forward log line carried the third instance - a carried-HOUR count over a POINT count - and DOCS quotes it verbatim, so it is corrected here too. 3. The plan reached no HTTP surface at all. `rows["Tariff"]` was `static_status()`'s 30 s-tick sentence and never saw the provider plan - it read 'no static profile' at all 802 soak samples on a site whose feed was answering. It now carries the plan's shape. ⚠️ The two sources are kept distinguishable: the plan half is stamped with its own age, measured from `tariff_at`, because it can be up to TARIFF_MAX_AGE_S (5400 s) old. FCST-04 pins that row to DOCS as a pair; DOCS moves in this commit. 4. `main.py`'s "if and only if" was false. `cycle()` returns at the input hold before `self.arb = None`, so an armed site read `off (arbitrage_enabled)` - naming an option that is on - and, after one completed cycle, showed a decision up to 15 s stale as a current one. The row now reads the OPTION and separates three facts; `cycle_at` and `arb_at` make "this cycle reached no decision" an observation. THE DELIVERABLE IS THE CHECK. All four survived 29 green suites because nothing graded the strings a human is shown. `test_price.py` section 12 renders through the shipped `status_payload()`, parses each number out of its OWN SLOT and compares it against a figure computed from the fixture's construction parameters - not from the property the row was built out of (habit 4), and not as a substring of a sentence the same file wrote (habit 14). The fixture set is four plan shapes and the check computes and prints the field pairs no fixture separates. The *Arbitrage* row's states are driven through real cycles with a sensor answering None and graded by INEQUALITY. No behaviour changed: no threshold, refusal rung, claim or setpoint moved. MUTATIONS: 16, no survivors, one at +0 B (the risky delta) and red. Two were found by the battery INSIDE THIS CARD'S OWN CHECK: a -190 B survivor whose fixture varied two things at once (habit 4), and a mutation whose red was a TRACEBACK in an f-string operand and therefore named nothing (FCST-06). Both closed; the table is on the PR. All 29 test files green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
f5ea39784d |
Merge release/1.0 (TARIFF-10) into TARIFF-12
checks / unit (pull_request) Successful in 7m16s
CHANGELOG.md was the only conflict: both entries belong under the same
`## Unreleased` heading, TARIFF-10's first because it merged first. No
version number picked.
app/main.py auto-merged, and was re-read because of it. TARIFF-10 changed
WHICH installs run `run_tariff_refresh()` (`arbitrage.enabled(opts)` ->
`tariff_refresh_wanted(opts)`); this card changed what that task does on
a failed fetch. Nothing in the keep/replace reasoning changed, and the
two newly reachable configurations are now DRIVEN in test_arbitrage.py
8b rather than reasoned about:
* a provider configured with trading DISARMED is the case the guard
was designed for, and needs no second fixture because nothing on
this path reads `arbitrage_enabled` at all - asserted over the AST's
symbols and non-docstring constants, after two drafts of that check
went red on a CORRECT tree for matching the word "arbitrage" in a
docstring and in a log line;
* `price_provider: off` + a `static_profile` resolves to the
CONFIGURED product (`origin: "static"`), so `standing.from_feed` is
false on every refresh and the guard never latches - driven twice in
a row, because a guard that latched there would freeze a static
site's plan at its first window for the life of the install.
Also: the kept-plan log line said "arbitrage stops with it", which after
TARIFF-10 is false on a site that fetches without trading; it now says
"arbitrage, where it is armed, stops with it". The keep decision is
strictly downstream of `resolve_tariff()`, so the §8.3 carry into
price_history - TARIFF-10's whole point - is unaffected either way.
All 29 suites green on the merged tree, including TARIFF-10's new
test_price.py section 13. All eleven mutations RE-DRIVEN on the merged
tree rather than carried over: eleven red, no survivors, every revert
fingerprinted. M11 is new - making the guard conditional on
`arbitrage.enabled(self.o)` (+86 B) is red on five named checks.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
c81289527f |
TARIFF-12: a returned degradation is not a refresh
checks / unit (pull_request) Successful in 7m12s
`run_tariff_refresh()` promised in its own docstring that "a failure does not clear the plan", and enforced it with `except Exception` - a branch a supplier outage never reaches. `load_prices()` states the reason in its own words: it "RETURNS, NEVER RAISES, for every failure a site can actually have", because a degradation arriving as a traceback into the planning tick would stop the controller regulating over an expired certificate. So a dead feed RETURNS a §11.4 plan, the `try` succeeds, and the assignment below it overwrote the good plan unconditionally. With `static_profile` unset - the shipped default, and the normal state of a dynamic-tariff site - `_degrade()` returns `TariffPlan(no_data, None, "none")`: a complete 48-hour plan replaced by nothing, at the FIRST failed fetch, ~27 minutes after the last good one. `TARIFF_MAX_AGE_S` (5400 s) never governed anything and there was no serve-stale window at all. Fourth card in one family: FCST-04's M4 (`not ok` only), FCST-05's HIGH (`(JSONDecodeError, OSError)` only), FCST-06 (`not self.ok` only), and now `except Exception` only, for a path that never raises. The question is now asked once, after the attempt, from the evidence that exists - FCST-06's answer, one module over. The evidence is `TariffPlan.from_feed` (did this resolution observe the configured feed) and the shipped `fresh_tariff_plan()`, reused rather than transcribed. A degradation replaces a standing observation only once that observation has aged out, so `TARIFF_MAX_AGE_S` is now the serve-stale window it reads like. A §11.4 static fallback does not replace a fresh provider plan either, although it carries real prices: every point `_degrade()` builds is `provisional=True`, so `firm_points()` is empty, `arbitrage()` refuses and `cheap_now()` is False - everything a consumer may act on is already off - while a day-ahead price for a given hour does not change once published. The rule is deliberately not symmetrical: a standing plan that is itself a degradation IS replaced, or an outage would freeze the operator's static profile at the window it was first generated for. `tariff_at` does not move on a kept plan. It is the moment of the fetch that produced the plan standing, `fresh_tariff_plan()` judges the age from it, and an unmoved timestamp is the only thing that tells a kept plan from a freshly fetched one. test_arbitrage.py section 8b drives the whole chain with nothing stubbed but the socket: the transport raises the way aiohttp does, load_prices() returns no_data, _degrade() builds the §11.4 plan, and the shipped run_tariff_refresh() decides. A check that patched resolve_tariff to RAISE would have passed against the defect. Ten mutations, ten reds, no survivors; 29/29 suites green. Out of scope and unchanged: the persisted price store still does not back the plan during an outage (FCST-03), and the status banner and the Arbitrage row's lag are separately carded. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |