At N>=2, when a battery's maintenance charge ended, its watts stayed in the
loop's start point and landed on the other battery (B 0 -> -1600 W in one
cycle, charging from the grid at a 6000 W house). On the cycle a charge
ends, the loop now starts from what the others stood at plus that
battery's new command. N=1 and all identity digests unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N>=2 a battery at or under its own peak reserve now weighs 0 whenever
the site gives (not only for the peak), a draining battery's pin becomes
a floor at its drain rate so it rises before the held one gives, and a
quarter's edge is graded on the next quarter when its first telegram is
late. SAFETY-25 option A stays: the held battery is still drawn once the
others are full. N=1 unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Rule 2 graded each battery against last cycle's command and graded charges
too. On plantsim's battery (10 s lag) at the 2 s meter it warned at every
drain or charge start and 15 times an hour under the peak guard at N=2; a
charge tapering near full warned 11 times in 50 min (SAFETY-42 section 7).
Now a discharge is graded against the least it stood at over SHORT_CYCLES /
SHORT_SPAN_S. DOCS lists `mode-bound` under Loop reason. test_safety85 part 7:
peak guard with a dead battery, lagging plant, taper; part 3: the bound ends
with maintenance.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The loop's integrator bound counts only on a cycle the loop decided. A battery
another owner set (maintenance, the peak guard, a safety limit) alarms only
when it gives more than saturation_w less than told for saturation_cycles
cycles. At N>=2 the loop is bounded while maintenance holds a battery, so it
does not wind and control comes back one slew step a cycle. The status row
counts episodes, not cycles. Digests re-pinned where behaviour changed on
purpose; DECISIONS/SAFETY-85-no-false-not-keeping-up.md has the list.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
At N>=2 a battery at or under its own peak reserve is held: it gives
nothing for the peak (weight 0 while the site gives) and the guard's need
is placed on the live, non-refusing batteries above theirs. The guard is
floor-limited, and alarms, only when those cannot hold the limit at full
power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold
the Home page at 0 W, because control keeps running. N=1 is byte-identical.
DECISIONS/SAFETY-87-guard-uses-able-batteries.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
During a HOLD the holding battery gives what keeps the quarter at the peak
aim. N=1: the peak floor is refiled at P_MAINTENANCE, as for a drain
(SAFETY-83). N>=2: the hold's pin is raised to the floor minus what the
other live batteries may place, so they give first. A site stop still
decides alone. The hold ends on its clock even if the level dipped.
Below the aim nothing changes (rows identical).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N>=2 a cheap-window maintenance charge files a site `hi` (`charge`,
P_MAINT_SHAPE) equal to what the charging pack's own `hi` places, so the
other pack never has to give against it. The charge is sized to the
quarter's headroom under the peak aim so it yields to the peak guard, and
to 0 W under a site safety stop. N=1 byte-identical (safety84_identity).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N=1 the drain is the site SET at P_MAINTENANCE (60), so the peak floor
(P_PEAK, 50) was not applied and the house imported what the drain left.
Where the floor asks for more than the drain rate, main.py now refiles the
peak claim at P_MAINTENANCE, so it wins; safety SETs still park everything.
Nothing else changes: safety78_identity --diff against 35cdffe changes only
cycles where the guard wanted more than the drain; N=2 is byte-identical.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Conflicts: modetrade.decide() takes both the day plan (targets) and
SAFETY-78's draining flag; the Why line keeps SAFETY-78's other_cycle
ahead of the plan's word (test added).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- DECISIONS: the Cheap hours change and why; the no-sun replay (the gain is
Leftover solar buying the evening's shortfall; the forecast added 0.14
EUR); the reconstruction bias stated plainly.
- DOCS: Cheap hours ignores the forecast; a reading from before midnight
is stale.
- The forecast line: "Solar still to come today: ..." (it is what is
left, and it stays within the 12-word limit).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Cheap hours only fills to the ceiling with or without a forecast, as the
design (section 1) says. Skipping the sun's share cost 0.31 EUR on real
2026 prices (29.72 against P3's 29.41) and saved nothing on the P3 set.
- A forecast reading from before local midnight is stale: until the
integration refreshes, "left today" is still yesterday's 0 and
"tomorrow" is really today.
- Forecast entity ids must be sensor.[a-z0-9_]+ (they go into the
/api/states/<id> path).
- House profile: a stored day that is not a date, or is after today, is
dropped instead of kept forever.
- Text: the forecast line says "for the rest of today"; the learning line
no longer promises "tomorrow" (a plan needs one full day).
- Tests for four surviving review mutants (hour sample floor, the dear run
after the cheap run, share by room, daytime use) and the fixes above.
- Replay tool: `--fc zero` (a forecast of no sun).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- The alarm must hold for peakguard.ALARM_HOLD_S (10 s) on the projection's
clock. A load that tops cap + battery for ~5 s every 30 s alarmed at every
quarter start while the quarter landed under the aim (sine4500_fast).
- A cycle with no battery reading leaves the hold alone.
- Notified once per quarter, but the ERROR line is written per episode.
- New sim scenarios (sine4500_fast, twice7000, step6500_gap) with 5a4cdc2
digests; control still byte-identical. Unit checks for export and the
hold across a missing reading. test_peakguard's saturated fixture moves
the hold start back instead of waiting it out.
- DECISIONS and DOCS updated: costs of the hold, tolerance reasoning, the
double count in control left to a follow-up.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The alarm now also needs peakguard.load_too_high(): with the battery at
full power, the quarter still ends more than 10 W over the real limit.
The battery reading is the lower of this cycle's and the last, so a meter
sample from before the battery's last increase is not counted twice.
At most one alarm per quarter. Control outputs unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At two inverters the drain pins its pack and the site target is split
around the pin. Below the pin the other pack had to charge, the allocator
refused the opposite directions, and the site sat at 0 W with an ARBITER
line every cycle (house below or above the drain rate, or a grid charge).
main.py now files a site limit `drain` (lo = what the pin places, at
P_MAINTENANCE) at N>=2 while a pack drains, so the other pack only adds
power in the same direction. A drain that cannot give power waits with
one log line. With battery modes on, no grid charge while a pack drains,
and the other battery's card says why. N=1 is byte-identical.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A Home Assistant solar forecast (Forecast.Solar, Solcast or Open-Meteo
shapes) and the add-on's own hourly house use decide, before each cheap
run, whether the sun will fill each battery before the expensive hours.
Leftover solar then buys from the grid only the shortfall; Cheap hours only
skips the part the sun covers; Solar first never grid-charges. No, stale or
failed forecast: P3 option A exactly (12 digests pinned from 5a4cdc2).
Replay (16 recorded days, forecast errors from Elia's day-ahead BE solar):
year-earlier prices P4 19.15 vs P2 19.33 / option A 19.44 / old trade 18.14;
real 2026 prices P4 29.19 vs 32.26 / 32.01 / 31.40 EUR net.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Owner decision 2026-09-29. Selling is off until it can be judged on the price
the grid pays: packmode.SELLING_ENABLED = False makes read() answer
sell=False whatever the store holds, pack_sell is refused ("Selling is off
for now."), and the page has no selling switch; the sell code stays. Until
the P4 forecast, only Cheap hours only charges from the grid
(packmode.GRID_CHARGE_MODES); Leftover solar holds and gives in the
expensive runs. Help, Today and plan lines, DOCS and DECISIONS follow.
Replay, 16 days: Solar first + Leftover solar 19.44 EUR net (P2 19.33).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- A sale block on the plan no longer says "Worth up to" at the import
price: a sale earns the lower injection price.
- The selling switch help (EN/NL) and DOCS say the grid pays less than
power costs; DECISIONS records why P3 loses on the replay.
- test_modes_p3 part 11: modes on ignore the site trade switch (R13), a
battery in maintenance takes no part (R10), a headroom stop latches for
the period (R8). All three mutants survived before and are red now.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Cheap and expensive hours as runs of consecutive firm price slots
(priceruns.py); each battery's role per tick from its mode (modetrade.py):
grid charging for Leftover solar / Cheap hours only, never Solar first;
holding for the expensive runs; selling per battery (pack_sell) above the
spread and the floor. The site trade is sized inside the modes (loop bound)
and the peak guard's headroom; a run edge reseeds the loop. Cheap hours only
and selling are enabled on the Batteries screen and in the HA select
(appended). The site Why row no longer says "held back" when the peak limit
pushes power up (F2). Modes off: byte-identical to 7a00f12 on the trade path.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- quarter_target_w() is now the margin under quarter_ceiling_w(): a peak
banked between cap - margin and the cap was aimed at exactly, so one
overshoot crossed the cap; above the cap the same overshoot raised the bill.
- safety79_identity.py hashes charge_headroom_w() and the shaping suspension,
and adds n1_maint/n2_maint (cheap window, forecast across cap - 50 .. cap).
Digests re-printed on ed739d4 and pinned; margin 0 still identical.
- test_margin_under_banked_peak; DECISIONS and DOCS updated.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- A refusal past the log-once set or the 32 cap is counted in the log at
1, 10, 100 and so on, so a repeated attack stays visible.
- The logged topic is printable only (no forged log lines).
- mode_announcement(): the start-up store logic, now tested with a real
Store. A removed config topic stays stored, so a start with no broker
cannot forget it (rename case tested).
- A test ties each HA mode option to the page's English name.
- packmode.enabled() is tested for "true", 1 and "false".
- Retained-command text, DOCS and DECISIONS updated to match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- The peak limit's Why and plan block need a real power request (floor above
0 W), not a blind or floor-limited guard. An Off battery gets the peak
block only while it gives power. Why no longer says every battery gives.
- test_batteries_screen pins the fixture clock: unpinned it failed every
morning. New checks cover the trade and cycle filters, the blind guard and
an Off battery that A covers alone.
- Settings keeps only a picked view; a link to Installer is not remembered.
- Browser check: badges, unsaved change across views, locked value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Each battery gets an MQTT-discovered Mode select and Use switch, only while
battery_modes_enabled is true. Commands go through handle_action(), the
/action path; refusals are logged once. Retained commands are never applied.
Turning modes off removes exactly the configs announced (kept in the store).
With modes off the announcement is byte-identical to ed739d4.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.
peak_margin_w 0 is byte-identical to ed739d4 (tools/safety79_identity.py,
test_peak_margin.py part 1). validate.py rule 12 refuses a value outside
0-500, not whole, or not below the peak limit.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
- Batteries: one card per battery with On/Off, the mode list (cheap hours
and selling greyed out until OPT-11 P3), level, and Now / Today / Why
lines built in homeview.py. Replaces the OPT-11 P1 minimal cards and uses
the existing pack_use / pack_mode actions and store keys.
- An Off battery the peak limit still needs says so with its figure; no line
shows 0 W beside moving power (OPT-11 P1 test F2). Today says "Not planned
yet" until OPT-11 P3/P4.
- Home's plan leaves Off batteries out, except for the peak limit.
- Settings opens on Simple: the layout's simple fields with an applies chip
and a note, plus the battery switches and modes. Installer is one tap.
- English and Dutch words in app/ui_text; test_batteries_screen.py; browser
check tools/ux13_browser_check.py (CHECK=1 ux13_screenshots.sh); new and
changed screenshots only.
No control, allocator, arbiter or command module changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
- arbiter: a mode now gives way only as far as a site limit above P_MODE
needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
released only when the peak floor bound S, so a trade won above the floor
kept them and placed less than the floor (an Off battery at N=1 went to 0 W
under a 2000 W floor), and a capped grid charge released an Off battery.
While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
(peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
loop bound counts live units only). DOCS and DECISIONS say the new rule.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English
fallback per key; the page picks by browser language. Home's sentences
move into ui_text `home_words`, so /status?lang=nl builds them in Dutch.
- test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon
lists for both languages, no inline details, untranslated Dutch caught.
Shared rules moved unchanged to tools/style_rules.py.
- tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in
headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot.
- "Other time windows": a list editor (ui.periods) that builds
static_profile and names bad times, empty prices, overlaps and gaps.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.
Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
R1: first_start also needs a Store created at this boot (Store.fresh), so
old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.
- First run: /config/model says `setup_needed` when the stored options name
no power request entity, or on a new install (no `setup_done` and no
`auto` in the Store, control not started). The page opens #setup only
when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
change decides: up keeps meter_invert off, down turns it on; a net or
import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
each power request entity exists in HA (bad if not, SAFETY-77), battery
levels and power with direction, solar sign, prices. Saves with
shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) *
LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both
units 10-16 times an hour after load steps (site held 0 W). 2 s and slower
ticks are unchanged.
- REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that
stops taking charge is always above its cut-out level.
- test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal;
the release/1.0 checks are restored and a span check added.
- test_refusal_units: lagged-reading and full-battery plants, two new checks,
U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R).
A unit that gives < 100 W for 12 cycles in one direction while asked
> 200 W, or trips its stale-reading gate on a ~0 W reading, gets a
P_SAFETY `refused` unit limit closing that direction, so the allocator
hands its share to the others within their own limits. Probe: a +-200 W
pin every 15 min, one unit at a time, only while the site asks 200 W that
way. All units refusing: the site law holds 0 W. Exits reseed the site
target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above
the configured cut-out; SAFETY-42/43 no longer report a refusing unit.
N=1 unchanged.
test_refusal_units.py: cases a/b/c on flat and jitter registers against
the old behaviour, probes, recovery, exits; mutations U1-U13 all red.
TEST-19 no-fault campaign: 0 engagements in 5280 runs.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's
own 100 W answer, not below saturation_w: a battery derated to 100-499 W
was held at 0 W ~93 % of the time.
- A reading of 100 W or more in the held direction ends the refusal, probe
or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy
reading's lag, and that held a healthy step at 0 W until the next probe.
- test_refusal part 5b and a seed test; DOCS states the N>1 limit; the
DECISIONS record carries the traced cause of the replay's extra trips.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At the BMS cut-out the saturation freeze held the last request for hours
(+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid
error changed sign. compute() now carries a refused direction: after
SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction
at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go
on charge, an answered probe, stop/start or another writer. A stale-reading
trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's
~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A).
test_refusal.py drives the real Controller and gate; tools/replay_refusal.py
replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined
where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what
SAFETY-58/59 must take into account.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- After a restart, each restored stop (direction per inverter and site,
delivery, circulation) also writes its saved reason to the action log.
log_level defaults to info and events starts empty, so the DEBUG
evidence alone left the figures only in state.json.
- A flapping meter (ha_signed under a flat load, 42-97 s between changes)
logs at most one WARNING/INFO pair per 10 minutes, with the episodes in
between at DEBUG.
- LONG_LINE_OK refuses any key whose text is a safety reason.
- test_watchdog keeps the byte pin beside the meaning pin, since the text
did not change.
- DOCS says the DEBUG line needs log_level debug.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Every WARNING/ERROR line that reported a safety reason (direction, delivery,
stuck meter, stale reading, peak guard, circulation, over-rating) now ends in
the reason's code (messages.reason_code()). The reason itself, figures and
limits included, is on a DEBUG line right after it and in the action log.
- The reasons and state.json are unchanged, so an old state file loads and
shows the same way: every saved reason opens with its code.
- test_messages part 6 checks every WARNING+ line at 25 words as logged; nine
non-safety families are listed with a reason and capped. The byte pin in
test_watchdog now pins the meaning, in order.
- The meter logs one WARNING per quiet episode, and INFO when back, so the red
row's "the add-on log shows why" holds. The Why line past the hold names
the missing reading. Action log: "25 engagements", "Shadow mode off: ...".
No trigger, latch, threshold, log level, notification id, cadence, row colour
or banner order changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
Part 6 checked the quoted reason alone, so title + reason + tails logged
as 4+ sentences. It now also checks the whole line (at most 3 sentences,
none over 30 words); 25 lines failed and are rewritten (one-sentence
wrappers, two-sentence circulation and peak reasons, STALE_READING's
fixed limits on a DEBUG line). The clamp lines for one inverter are
pinned at 30 words with OUTPUT_CLAMP and the numbers kept. Home
Assistant's bare '400: Bad Request' while it loads becomes one plain
line; still WARNING, throttled, a failed write.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified
as data or as a built text, and every built text is produced by the real
code and checked. This is the gap the 2d scan had: it counted `%s` as one
word, so reasons built by loop_clamp_note() and friends were never seen.
- Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept):
OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak
guard (codes now PEAK_GUARD*), the migration report, price feed, price
history and gate reasons. Plurals via messages.times()/count().
- Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff
"one every 15 minutes or every hour", "not final yet" dropped.
- Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO,
aiohttp access log only at log level debug, settings warnings once per
start, one plain line per Home Assistant outage (hass.Outage).
- INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE",
"NOT_OBSERVED", "did NOT land", "AND".
- Display bugs: WHY_WINNER covers every winner and safety reason
(main.why_key(), part 7 finds them in the code); the meter row is amber
"waiting for the first reading" inside its limit after a start; the
missing-reading age is counted when the page asks.
- STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section).
No change to safety behaviour, alarm levels, notification ids, triggers,
cadence or the banner cascade. One row colour changes (meter at start),
justified in DECISIONS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- status_payload() also returns the action log as `events`. The page
does not render it. Some entries (a dropped inverter's reason, the peak
guard's projection, unplaced watts) are written nowhere else, and DOCS
still points installers at the action log.
- test_peakguard pins the engaged row's ordered pair (the battery's share,
then the limit).
- test_messages expands setting keys named by constants imported from
another app module, so the shown-text 30-word scan counts them.
- p1.py: 'A meter message could not be read'. DOCS glossary: control
board in plain words, with the hardware in an installer note.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Every WARNING and ERROR line is one plain line of at most 25 words, with
no card ids, capitals or semicolons; the reasoning of the ten longest is
on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0).
The status page: the month-peak and peak-guard rows, the stale-reading
row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the
Stopped banner and the line under the buttons, which now shows the plain
hint of each event instead of the raw action log. The Supervisor question
at start logs one line with a real reason.
Refusals are counted as shown (labels expanded, long cases driven), seven
were shortened, the card and parse errors lost their internals, a blank
value reads "empty", and the panel no longer files inverters.max_w under
the flat max_w. Option names lose "(JSON)", the NL texts are checked too.
DOCS gets a glossary (control board, isolator, Developer Tools) and card
ids move from headings to a "For installers" line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- messages.setting() for one inverter in the list reads
“Inverter rating” for inverter-b (inverters.max_w), so the config panel
files per-unit reasons under `inverters`, where the value is changed.
- The tariff card and plausibility reasons name
“Distribution, levies and VAT” (price_taxes_eur_kwh) again.
- The wrong-direction reasons say "safety stop", the sign_disagree_w
option says what it protects, and the roster, price-entity,
integrator_max_w and capacity_kwh texts read more plainly.
- NL: stuurprint -> stuurmodule, "De piekbeperking".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Validator refusals name the setting by its label and key, say what is
wrong and what to change, and keep the rejected value and limit. Option
names and descriptions are short in en and nl; citations moved to DOCS
"For installers" and the test_translations citation check now pins the
instruction on the tab and the record in DOCS. No rule, key, schema,
default or exit code changed. Allowlist 167 -> 43 (log lines only).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p