release-0.18.1
171
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
e6096d3e17 |
Merge release/1.0 (7337b79, OPT-11 P2) into safety-79-peak-margin
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
308adc9277 |
Merge release/1.0 (7995e4d, UX-13 P3) into opt11-p2-ha-entities
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c664e38ef4 |
OPT-11 P2 review: refusals stay counted, removals survive a start with no broker
- A refusal past the log-once set or the 32 cap is counted in the log at 1, 10, 100 and so on, so a repeated attack stays visible. - The logged topic is printable only (no forged log lines). - mode_announcement(): the start-up store logic, now tested with a real Store. A removed config topic stays stored, so a start with no broker cannot forget it (rename case tested). - A test ties each HA mode option to the page's English name. - packmode.enabled() is tested for "true", 1 and "false". - Retained-command text, DOCS and DECISIONS updated to match. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
0951cb227f |
Merge release/1.0 into safety-79-peak-margin
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> # Conflicts: # goodwe_controller/app/uilayout.py |
||
|
|
a9f7d78527 |
UX-13 P3 review: truthful peak lines, a clock-proof test, Simple stays default
- The peak limit's Why and plan block need a real power request (floor above 0 W), not a blind or floor-limited guard. An Off battery gets the peak block only while it gives power. Why no longer says every battery gives. - test_batteries_screen pins the fixture clock: unpinned it failed every morning. New checks cover the trade and cycle filters, the blind guard and an Off battery that A covers alone. - Settings keeps only a picked view; a link to Installer is not remembered. - Browser check: badges, unsaved change across views, locked value. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
b310282729 |
OPT-11 P2: HA entities for battery modes
Each battery gets an MQTT-discovered Mode select and Use switch, only while
battery_modes_enabled is true. Commands go through handle_action(), the
/action path; refusals are logged once. Retained commands are never applied.
Turning modes off removes exactly the configs announced (kept in the store).
With modes off the announcement is byte-identical to
|
||
|
|
7c4c8f5c66 |
SAFETY-79: peak guard keeps a margin below the limit
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.
peak_margin_w 0 is byte-identical to
|
||
|
|
2d2b6afb07 |
UX-13 P3: Simple view and Batteries screen
- Batteries: one card per battery with On/Off, the mode list (cheap hours and selling greyed out until OPT-11 P3), level, and Now / Today / Why lines built in homeview.py. Replaces the OPT-11 P1 minimal cards and uses the existing pack_use / pack_mode actions and store keys. - An Off battery the peak limit still needs says so with its figure; no line shows 0 W beside moving power (OPT-11 P1 test F2). Today says "Not planned yet" until OPT-11 P3/P4. - Home's plan leaves Off batteries out, except for the peak limit. - Settings opens on Simple: the layout's simple fields with an applies chip and a note, plus the battery switches and modes. Installer is one tap. - English and Dutch words in app/ui_text; test_batteries_screen.py; browser check tools/ux13_browser_check.py (CHECK=1 ux13_screenshots.sh); new and changed screenshots only. No control, allocator, arbiter or command module changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV |
||
|
|
ffc9a4d721 |
OPT-11 P1 review: a mode never beats the peak floor; SAFETY-03 kept at the rail
- arbiter: a mode now gives way only as far as a site limit above P_MODE
needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
released only when the peak floor bound S, so a trade won above the floor
kept them and placed less than the floor (an Off battery at N=1 went to 0 W
under a 2000 W floor), and a capped grid charge released an Off battery.
While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
(peak floor, trades, maintenance, refusals);
|
||
|
|
d69fd8fbfd |
OPT-11 P1: per-battery mode limits, on/off, solar order
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to
|
||
|
|
667b8e9145 |
UX-13 P5: Dutch text, STYLE check, DOCS screenshots, period editor
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English fallback per key; the page picks by browser language. Home's sentences move into ui_text `home_words`, so /status?lang=nl builds them in Dutch. - test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon lists for both languages, no inline details, untranslated Dutch caught. Shared rules moved unchanged to tools/style_rules.py. - tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot. - "Other time windows": a list editor (ui.periods) that builds static_profile and names bad times, empty prices, overlaps and gaps. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
30cba1e58d |
UX-15 review: shorter setup banner (PR #147)
The Home banner title was ten words; UX-08 asks for about six. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
159d7461d8 |
UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only refusal, the add-on now serves the setup wizard in setup-only mode instead of exiting 78. It builds no controller, MQTT client or meter task, its HomeAssistant is read-only (every service call refuses before sending), Controller refuses a read-only HomeAssistant, and /action answers 409. Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md. Wizard fixes from the UX-13 P4 test: - F1: /config/validate converts what it can, so a conversion error blocks its own step and the live checks still run; save 422 carries steps. - F2: saves send the model the page opened (base); only keys this page changed are written onto the blob stored now. - A meter entity missing from Home Assistant is red on the last step. - Step 1 says the reading went down after a skip that followed a fall. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
3198f346fd |
UX-13 P4 review fixes (PR #146, comment 1887)
R1: first_start also needs a Store created at this boot (Store.fresh), so
old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
|
|
be57b87c34 |
UX-13 P4: the setup wizard for installers
The Setup tab draws the Installer view's page model one step at a time, from each field's `wizard` step in app/uilayout.py: meter (with the kettle test), inverters and batteries, solar (optional), prices, peak limit (battery modes: "comes in a later update", OPT-11), check and start. It reuses P2's controls and saves through /config/validate and /config/save. No route was added. - First run: /config/model says `setup_needed` when the stored options name no power request entity, or on a new install (no `setup_done` and no `auto` in the Store, control not started). The page opens #setup only when opened with no route. The wizard's save writes `setup_done`. - Kettle test: GET ha/entities?entity= reads one entity now, in W. The change decides: up keeps meter_invert off, down turns it on; a net or import/export meter that goes down blocks the step with what to check. - Last step: validate.setup_checks() beside the refusals: the meter reads, each power request entity exists in HA (bad if not, SAFETY-77), battery levels and power with direction, solar sign, prices. Saves with shadow_mode on by default, then a confirmed restart naming the 0 W. - P2 test finding (a): a stale save lists only the keys the other surface moved (the blob handed out on open, by fingerprint, against stored now). - test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard can save; all accepted by Supervisor 2026.08.0 AppOptions (offline). - DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install". Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
06aa09e28c |
SAFETY-73 review: a refusal needs 22 s of evidence, and the cut-out warning is for giving only
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) * LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both units 10-16 times an hour after load steps (site held 0 W). 2 s and slower ticks are unchanged. - REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that stops taking charge is always above its cut-out level. - test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal; the release/1.0 checks are restored and a span check added. - test_refusal_units: lagged-reading and full-battery plants, two new checks, U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
016ed5a5a3 |
SAFETY-73: a battery that refuses, per inverter, with two or more
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R). A unit that gives < 100 W for 12 cycles in one direction while asked > 200 W, or trips its stale-reading gate on a ~0 W reading, gets a P_SAFETY `refused` unit limit closing that direction, so the allocator hands its share to the others within their own limits. Probe: a +-200 W pin every 15 min, one unit at a time, only while the site asks 200 W that way. All units refusing: the site law holds 0 W. Exits reseed the site target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above the configured cut-out; SAFETY-42/43 no longer report a refusing unit. N=1 unchanged. test_refusal_units.py: cases a/b/c on flat and jitter registers against the old behaviour, probes, recovery, exits; mutations U1-U13 all red. TEST-19 no-fault campaign: 0 engagements in 5280 runs. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
3c0f2b9669 |
SAFETY-52 review: a refusal is under 100 W, and any delivery ends it
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's own 100 W answer, not below saturation_w: a battery derated to 100-499 W was held at 0 W ~93 % of the time. - A reading of 100 W or more in the held direction ends the refusal, probe or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy reading's lag, and that held a healthy step at 0 W until the next probe. - test_refusal part 5b and a seed test; DOCS states the N>1 limit; the DECISIONS record carries the traced cause of the replay's extra trips. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
1f97c7652f |
SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
At the BMS cut-out the saturation freeze held the last request for hours (+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid error changed sign. compute() now carries a refused direction: after SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go on charge, an answered probe, stop/start or another writer. A stale-reading trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's ~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A). test_refusal.py drives the real Controller and gate; tools/replay_refusal.py replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what SAFETY-58/59 must take into account. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
3c298af3d8 |
UX-11 review: restored stops log their figures to events, the quiet-meter WARNING is rate-limited
- After a restart, each restored stop (direction per inverter and site, delivery, circulation) also writes its saved reason to the action log. log_level defaults to info and events starts empty, so the DEBUG evidence alone left the figures only in state.json. - A flapping meter (ha_signed under a flat load, 42-97 s between changes) logs at most one WARNING/INFO pair per 10 minutes, with the episodes in between at DEBUG. - LONG_LINE_OK refuses any key whose text is a safety reason. - test_watchdog keeps the byte pin beside the meaning pin, since the text did not change. - DOCS says the DEBUG line needs log_level debug. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
29837dfaa7 |
UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG
- Every WARNING/ERROR line that reported a safety reason (direction, delivery, stuck meter, stale reading, peak guard, circulation, over-rating) now ends in the reason's code (messages.reason_code()). The reason itself, figures and limits included, is on a DEBUG line right after it and in the action log. - The reasons and state.json are unchanged, so an old state file loads and shows the same way: every saved reason opens with its code. - test_messages part 6 checks every WARNING+ line at 25 words as logged; nine non-safety families are listed with a reason and capped. The byte pin in test_watchdog now pins the meaning, in order. - The meter logs one WARNING per quiet episode, and INFO when back, so the red row's "the add-on log shows why" holds. The Why line past the hold names the missing reading. Action log: "25 engagements", "Shadow mode off: ...". No trigger, latch, threshold, log level, notification id, cadence, row colour or banner order changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
e0b578756f |
UX-10 review: the line as logged gets the red-alarm shape, clamp lines at 30 words, plain HA 400
Part 6 checked the quoted reason alone, so title + reason + tails logged as 4+ sentences. It now also checks the whole line (at most 3 sentences, none over 30 words); 25 lines failed and are rewritten (one-sentence wrappers, two-sentence circulation and peak reasons, STALE_READING's fixed limits on a DEBUG line). The clamp lines for one inverter are pinned at 30 words with OUTPUT_CLAMP and the numbers kept. Home Assistant's bare '400: Bad Request' while it loads becomes one plain line; still WARNING, throttled, a failed write. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
23a3a3f5b5 |
UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified as data or as a built text, and every built text is produced by the real code and checked. This is the gap the 2d scan had: it counted `%s` as one word, so reasons built by loop_clamp_note() and friends were never seen. - Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept): OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak guard (codes now PEAK_GUARD*), the migration report, price feed, price history and gate reasons. Plurals via messages.times()/count(). - Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff "one every 15 minutes or every hour", "not final yet" dropped. - Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO, aiohttp access log only at log level debug, settings warnings once per start, one plain line per Home Assistant outage (hass.Outage). - INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE", "NOT_OBSERVED", "did NOT land", "AND". - Display bugs: WHY_WINNER covers every winner and safety reason (main.why_key(), part 7 finds them in the code); the meter row is amber "waiting for the first reading" inside its limit after a start; the missing-reading age is counted when the page asks. - STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section). No change to safety behaviour, alarm levels, notification ids, triggers, cadence or the banner cascade. One row colour changes (meter at start), justified in DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
569f16aa91 |
UX-08 2d review: action log reachable in status JSON, engaged peak row pinned, imported keys expanded
- status_payload() also returns the action log as `events`. The page does not render it. Some entries (a dropped inverter's reason, the peak guard's projection, unplaced watts) are written nowhere else, and DOCS still points installers at the action log. - test_peakguard pins the engaged row's ordered pair (the battery's share, then the limit). - test_messages expands setting keys named by constants imported from another app module, so the shown-text 30-word scan counts them. - p1.py: 'A meter message could not be read'. DOCS glossary: control board in plain words, with the hardware in an installer note. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
6a95447248 |
UX-08 2d: plain log lines, the rest of the status page, and DOCS
Every WARNING and ERROR line is one plain line of at most 25 words, with no card ids, capitals or semicolons; the reasoning of the ten longest is on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0). The status page: the month-peak and peak-guard rows, the stale-reading row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the Stopped banner and the line under the buttons, which now shows the plain hint of each event instead of the raw action log. The Supervisor question at start logs one line with a real reason. Refusals are counted as shown (labels expanded, long cases driven), seven were shortened, the card and parse errors lost their internals, a blank value reads "empty", and the panel no longer files inverters.max_w under the flat max_w. Option names lose "(JSON)", the NL texts are checked too. DOCS gets a glossary (control board, isolator, Developer Tools) and card ids move from headings to a "For installers" line. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
c84d5fd14f |
UX-08 2c review: unit settings anchor to inverters, plainer texts
- messages.setting() for one inverter in the list reads “Inverter rating” for inverter-b (inverters.max_w), so the config panel files per-unit reasons under `inverters`, where the value is changed. - The tariff card and plausibility reasons name “Distribution, levies and VAT” (price_taxes_eur_kwh) again. - The wrong-direction reasons say "safety stop", the sign_disagree_w option says what it protects, and the roster, price-entity, integrator_max_w and capacity_kwh texts read more plainly. - NL: stuurprint -> stuurmodule, "De piekbeperking". Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
2c516a032c |
UX-08 2c: short refusals, error texts and option texts
Validator refusals name the setting by its label and key, say what is wrong and what to change, and keep the rejected value and limit. Option names and descriptions are short in en and nl; citations moved to DOCS "For installers" and the test_translations citation check now pins the instruction on the tab and the record in DOCS. No rule, key, schema, default or exit code changed. Allowlist 167 -> 43 (log lines only). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
00e3ee9de8 |
UX-09: Details link for current HA, "would" in shadow mode, plain terms
- Details link: /config/app/<slug>/documentation on HA 2026.2+ (the old /hassio/addon path is a 404 from 2026.5), /hassio/addon on 2026.1 and older. Slug from GET /addons/self/info, version from GET /info, hostname as fallback. - Shadow mode: the over-rating alarm and row say what would have been sent, the peak alarm no longer says the battery is giving all it can. - "controller" -> "the add-on" / "control". Settings named by their labels; four labels changed to match (Peak reserve, Battery level entity, Solar production ..., Reversed-sign solar entities). - Shadow banner and inverter link notes moved to messages.py and checked. - DOCS Notifications and Status page rewritten for home owners, with a "For installers" part each. Allowlist 168 -> 167. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
571b884315 |
UX-08 phase 2b review: keep over-rating evidence, pin latch clearing, plainer rows
- During a bound episode an earlier over-rating count stays on the page (amber, under its own title); test_clamp pins it. - test_messages pins that every latch row says how it clears. - pv_entities description no longer claims the page names the entity (en, nl); allowlist hash updated for that option-desc line. - Plainer texts: multi-inverter direction banner, "fine now" after an episode, and the e-stop, peak-forecast and peak-guard-waiting rows move to messages.py. - TEL-12 DECISIONS points to UX-08 item 3 for the retired row rule. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
d017fc67bf |
UX-08 phase 2b: short, plain status rows and page banners
Every Commissioning row and every page banner is now worded in app/messages.py (row_*, banner_*): one sentence of at most 15 words, a red row up to three sentences so a latch still says how it clears, banners at most 12 words. No row names a Home Assistant entity: sensors by their setting, solar sources by their place in the list. Reason codes and limits stay on the log line and event list; rows keep the numbers a reader acts on. UX-07 item 1: ClampWatchdog counts over-rating and integrator-bound engagements separately, and after an episode each count shows under its own alarm's title instead of both under "output clamp". No row colour, visibility or banner order changed. Rows carry an "id" so the tests pin meaning rather than wording. The row and banner kinds leave the allowlist (200 -> 168, cap equal). DOCS.md gains "Status page"; choices are in DECISIONS/UX-08-short-notifications.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
7b65a3e69a |
UX-08 review: tighter notification texts, and two meaning fixes
- not delivering: the body said control keeps running and then "start
control"; clearing it takes stop then start, and it now says so.
- peak reserve: the "reserve not set" branch is really soc_floor None,
i.e. an inverter's cut-out level missing; it now names that. The title
is true on all three branches ("Battery stopped limiting the peak").
- no semicolon run-ons in bodies (STYLE.md + test); loop-bound, circulating,
meter-frozen and multi-unit over-rating bodies rewritten to match.
- allowlist cap is now exact, so a shrink cannot leave room to regrow.
- DOCS names the settings behind "peak reserve" and "cut-out level";
DECISIONS no longer states the HA anchor behaviour as fact.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
|
|
50ccea3dd7 |
UX-08 phase 2a: short, plain notifications, and a ratchet for the rest
Every HA notification the add-on raises now has a title of at most 5 everyday words and a one-sentence body; a red alarm may use three so no action is lost. The texts live in app/messages.py, the rule in STYLE.md, and the detail that moved out in DOCS.md "Notifications", which each body links to. No notification_id, trigger or cadence changed. test_messages.py enforces the rule on every notification, fails any notification worded outside app/messages.py, and ratchets the kinds not yet rewritten (rows, banners, refusals, logs, options) through a shrinking allowlist of 200. Six tests re-pinned from prose to meaning. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
55a6d5dcdb |
SAFETY-40 review: integrator-bound WARNING gets its own notification id
A later anti-windup notice could replace a write-path BUG SIGNAL notice
under the shared goodwe_output_clamp id (escalation ignores the budget).
The WARNING now uses goodwe_integrator_bound and points to DOCS; the
cadence sentence in DOCS is corrected. Tests pin both ids (red on
|
||
|
|
fd14569a71 |
SAFETY-40: the integrator bound is not a BUG SIGNAL; numbers from the clamp tick
The clamp alarm gave `i_clamped` (normal anti-windup) the over-rating BUG SIGNAL text, printed `Decision.i_w` as "the loop asked for", and printed `self.target` (after slew/freeze) as "was clamped to". - clamp.loop_clamp_note(): i_clamped says "the loop's integrator reached its N W anti-windup bound" with this tick's command; clamped keeps BUG SIGNAL with the requested command and the clamp's own result. - Decision carries i_bound_w / requested_w / clamped_w, set at the clamp. - i_clamped still counts and notifies (same id, cadence, SAFETY-41 escalation) but as a WARNING, amber row, plain title. A bug has its own notification budget and its text is not overwritten within an episode. - test_clamp.py part 9: red on the old code per defect; 5 mutations killed. - DOCS.md alarm section (and its stale 30 s cadence), DECISIONS/SAFETY-40. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
16c796fa30 | Merge pull request 'TEL-14: PV sign declared per entity (pv_invert_entities)' (#124) from TEL-14-pv-sign into release/1.0 | ||
|
|
d71f7dbd35 |
Merge release/1.0 (43b2740) into DOC-5-watchdog to sync base
checks / unit (pull_request) Successful in 8m45s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
7559d21eda |
TEL-14: PV sign declared per entity (pv_invert_entities)
checks / unit (pull_request) Successful in 8m39s
Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive for consumption and negative for production. `pv_invert_entities` lists the ones to flip; the flip is applied per member inside pv.total(), before the sum, so the MQTT `pv` row and the status page carry the corrected figure. Default [] is byte-identical to 0.12.0. Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0): a parallel list validates the 0.12.0 blob unchanged and renders as its own translated repeatable field; dicts on pv_entities refuse 0.12.0's stored strings; a prefix is invisible syntax; a global bool cannot describe a mixed roster. Status page marks flipped entities and cautions per entity below -50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged. Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
3e38bafcee | Merge pull request 'SAFETY-62/SAFETY-60: operator tools refuse input they cannot read' (#120) from SAFETY-62-refuse-unread-input into release/1.0 | ||
|
|
02a822af98 |
DOC-5: tell installers to turn on the Supervisor Watchdog
checks / unit (pull_request) Successful in 8m41s
Since SAFETY-61 a dead control loop writes 0 W and exits 70. The Supervisor restarts a stopped add-on only when the per-install Watchdog toggle is on, and it defaults to off. One step in DOCS.md "Before you start", with a pointer to the DECISIONS file. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
b06f1fad5f |
SAFETY-62 review: DOCS exit 3 at the command block (R1); recognise the auto store key (R2)
checks / unit (pull_request) Successful in 8m35s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
f4f72211a9 |
SAFETY-60/62: operator tools refuse input they cannot read
checks / unit (pull_request) Successful in 8m31s
predeploy_check.py and rehearse_roster.py now assert a positive property of their input (a JSON object, most of whose top-level keys are known option or store keys) and refuse anything else with the shape named. The `ha apps info --raw-json` wrapper, a truncated or list-wrapped state file and a wrapped config no longer produce "CLEARED" / "NO FINDINGS" with exit 0. Also: a clean --no-live-entities rehearsal exits 3, not 0; alloc_sim.py exits 1 when split-invariance FAILS; decode_bus_capture.py takes several paths and exits 1 on a file that is mostly not frames. Graded by the new test_tool_inputs.py; DOCS.md says to pass .data.options. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
29ca9b5157 |
DOC-1: operator docs name the real P1 entity and a roster that starts
checks / unit (pull_request) Successful in 8m8s
- DOCS.md / config.yaml: the watchdog's P1 age entity is sensor.goodwe_p1_sample_age (device "GoodWe" + "P1 sample age", as app/mqtt.py announces and the live install recorded), not sensor.p1_sample_age_s. - DOCS.md: the inverters: example and per-entry table carry the required bms_soc_floor (and capacity_kwh); config.yaml's schema comment says four required keys, not three. - Field guide: marked v0.1.0/outdated; slew_w row no longer recommends the 1000 W that SAFETY-39 now refuses. HTML regenerated; the PDF is NOT rebuilt (no Chrome here). README/DOCS pointers fixed. - test_docs.py: the documented roster must pass app/validate.py and the schema's per-entry keys; the documented entity id must equal the id composed from app/mqtt.py; the wrong id may appear in no shipped doc. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
0ef9565071 |
TEL-12: several PV inverters, and one absent member is an absent TOTAL
checks / unit (pull_request) Successful in 7m59s
0.11.0 shipped `pv_entity` as a single string. The reference site's owner reported within minutes of it going live that they have several PV inverters and could configure one - which is ordinary for a multi-string roof, not a property of one house. `pv_entities` is the roster and the row carries the SITE total. ⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`, and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no irradiance" conclusion the channel exists to TEST. So `pv.total()` answers `None` the moment any configured entity is absent: the topic carries HA's own `None`, the entity goes to `unknown`, the recorder records a GAP. The alternative (the partial sum beside a contributor count) was implemented and run as mutation N1b; it loses because the MQTT row is read COLD a week later by an attribution that would believe it, while the qualifying count would live in a second entity with its own history. The partial information is not thrown away - the STATUS PAGE names every entity that reported, with its watts, and every one that did not, with its reason, because that surface is read LIVE by a human who wants the diagnostic. ⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is `is None`, never falsiness - a roster that blanked the site on a zero would report an absence on every clear evening. THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list: tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an 0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and deepmerge's list strategy is `override` so a `[]` default does not rescue it - the live add-on would not start. `match(.*)?` does accept both shapes and is rejected for a different, measured reason: it validates nothing (a string, a list and the integer 417 all pass) and renders as a plain text box. So `pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for `inverters:`, with a status caution saying which key won - a union would double-count the inverter the old key still names. STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than replaced and now grades five claims over three document sets. The control hash is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the roster control document is byte-identical between the two trees. 2/5 is a claim TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly as 0.11.0 does" is a real cross-tree identity over control AND telemetry. ⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit 24: a discriminator defined as "the baseline lacks this feature" dies on the release that ships the feature, and dies as a false refusal. Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B (`sum` -> `max`, the same three characters) and was run on a fresh copy with `cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO contributions in two units with absence driven at EVERY position - a member contributing 0 W could go absent without moving the sum of the rest, which is habit 23 with a coinciding value in the arithmetic rather than in the plant. 31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0, so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG entry is wanted and deliberately not written - 11b forbids `## Unreleased` and the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the material it needs. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
07ba3433ed |
TEL-11: PV production stops being invisible, and stays out of the control law
checks / unit (pull_request) Successful in 8m6s
OPT-10 measured that this site's pack reaches 90 % SoC on 2 days of 16 and that
20.5 kWh of surplus left the site while the pack had room - 12.6 kWh of it with
the battery not charging at all - and could not say WHY, because PV production
is recorded NOWHERE. Three causes need three different fixes (no irradiance:
nothing to fix; a charge-power limit; the optimiser declining to charge, which
is the only software defect) and guessing between them is how an optimiser gets
tuned to solve a cloud problem. This card adds the channel. It does not do the
attribution.
AN HA ENTITY, NOT A REGISTER, AND THAT IS A PRODUCT DECISION. This add-on's
RS485 bus carries the BATTERY inverter it drives; a household's PV inverter is
normally a different box from a different vendor reporting into Home Assistant
through its own integration. `pv_entity` takes whatever `sensor.*` the site's
own PV integration provides, any brand HA can read.
POSITIVE IS PRODUCTION, AND THERE IS NO `pv_invert`. The convention is derived
rather than assumed: `meter_entity` is positive when IMPORTING and `batt_entity`
is positive when DISCHARGING (DOCS.md, Sources), both of which are "power
arriving at the house's AC bus", and production arrives there too. Those two
keys carry invert flags because they are BIPOLAR and are READ BY THE CONTROL
PATH - `inv.batt` feeds SAFETY-30's per-unit sign check and SAFETY-31's
circulating-power sensor, so a reversed sensor hands the site a plausible number
it acts on. Production is unipolar and is read by nothing: a reversed sensor
announces itself as -4 kW at noon in the very history this card creates, and a
flag would only let an installer hide it. No negative-value alarm either - a PV
inverter's own standby draw makes a small negative reading at night ordinary, so
any threshold would be a number nobody measured.
ABSENCE IS NEVER ZERO, AND "DROPPED" IS NOT ABSENT. `publish()` SKIPS a None,
which is right for `circulation` and exactly wrong here: a skipped row leaves
Home Assistant holding the last number forever and the recorder draws a FLAT
LINE through the outage, which is indistinguishable from a measurement and
manufactures the "there was no surplus" conclusion this card exists to TEST. So
the absence is published, with HA's own payload: `mqtt/const.py` declares
`PAYLOAD_NONE = "None"` and `mqtt/sensor.py` tests it BEFORE the numeric branch,
so the entity's state becomes `unknown` and the recorder stores a GAP. Read out
of home-assistant/core `dev` on 2026-09-24 and quoted at the constant.
`ABSENT_AS_UNKNOWN` is a one-key set and the suite asserts `circulation: None`
is STILL dropped.
THE UNIT IS READ OFF THE ENTITY. `mW`, `W`, `kW`, `MW`, `GW`, `TW` - HA's own
`UnitOfPower`, every factor an exact power of ten. A sensor with no unit, or a
unit outside that table, is REFUSED by name and the status page says which.
`read_inputs()`'s `abs(raw) < 50` kW-or-W guess is safe for a quarter-hour
demand forecast and is NOT safe here: 30 W of dusk is an ordinary reading and
that heuristic would publish it as 30 kW.
GENUINELY OPTIONAL, AND NOT A SECOND `price_now_entity`. validate.py does not
mention the key - it cannot conflict with anything, because nothing else reads
it. The MQTT row lives in a new `OPTIONAL_SENSORS` list whose `include` argument
DEFAULTS TO EMPTY, so every caller that has never heard of `pv_entity` -
test_mqtt.py's fixtures, tools/rehearse_roster.py, anything written next year -
announces exactly what it announced before. Unset: no state call at all, no
entity, no topic, no status row, no page row. Set and failing: a CAUTION
(`ok=False, warn=True`), never a `bad` row, so a telemetry channel can never put
a battery site into NOT READY.
IT MUST NOT BECOME A CONTROL INPUT, AND THAT IS GRADED TWICE. `test_pv.py`
part 6 drives 40 cycles of the real `cycle()` and asserts the commands are
bit-identical across unset / no reading / 0 W / 8 kW, with a COMPUTED census
(33 modules under app/) showing the material is mentioned in exactly three:
pv.py, main.py, mqtt.py. `tools/tel11_pv_trace.py` is the cross-tree half -
`safety56_behaviour_trace.py`'s pattern with a DIFFERENT control clause, because
this card's claim is that nothing differs rather than that only sentences do: it
REFUSES unless the two `app/` fingerprints differ and unless exactly one side
reacts to the option. Measured on 41 stimulus cells:
control release/1.0 unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
control TEL-11 unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
control TEL-11 set 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
telemetry release/1.0 unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
telemetry TEL-11 unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
telemetry TEL-11 set 4e6d1cb289a957223ad0205f732a6fec6110ce1f2032c98ad60694e67625274f
UNSET is byte-identical in BOTH documents, which is stronger than "the control
path is untouched": an install that does not set the option sees no change of
any kind, announcement and status rows included.
⚠️ AND THE CARD'S CENTRAL MUTATION WAS A SURVIVOR ON THE FIRST BATTERY.
`self.grid -= self.pv_w` in `read_inputs()` - +106 B, on disk, purged, genuinely
running - came back GREEN, because the fixture drove a 6 kW export over 12
cycles, which puts the loop AGAINST ITS RAIL: a command moving `slew_w` every
cycle produces the same ramp for -6000 W and for -14 000 W of apparent error.
MUTATION.md habit 23 with a saturated ACTUATOR in place of a coinciding value,
and it is in that file now as the habit's second instance. The fixture now
drives a 600 W import the loop SETTLES on, against a responsive meter, and asks
habit 23's own question as its own check: shift the METER by the same 8 kW and
confirm the commands really would have moved.
Evidence: 31/31 suites green in the CI image, checks.yml's exact command, purged
tree, `:ro`. Ten mutations, NO survivors, each on its own `cp -a` of the tree so
habit 18's revert hazard is closed by construction - table in
`DECISIONS/TEL-11-pv-production.md` §7 with byte deltas and sha256s.
⚠️ THIS IS A RUNTIME CHANGE BEHIND AN UNCHANGED VERSION, AND
`tools/predeploy_check.py` WILL REFUSE IT. `app/`, `config.yaml` and
`translations/` are all in its `RUNTIME` tuple and `config.yaml` still reads
0.10.1, so the gate reports a NO-OP deploy until a version is cut. That is PKG's
call and this card does not take it.
No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading
that is not config.yaml's `version:`, and opening one would mean taking that
same packaging decision. The operator account is in DOCS.md.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
43c144b8d9 |
SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.
REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:
10:51:24.7 0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
10:51:29.7 the command reaches +1060 W - 800 W of travel
10:52:00 the conjunction arms. Inverter.batt becomes None
10:52:21.7 the site commands 0 W, on the wire
... 0x0518 does not change value for 850.0 s. The setpoint does not
change value for 790.0 s. The house exports 2.4 kW throughout
~11:04 a human restarts the add-on. That is what ends it
AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.
THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.
THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:
the verdict is withdrawn when the obligation that produced it has been gone
for RELEASE_S, and the register is then re-graded from scratch.
RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.
The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.
WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.
Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.
main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.
Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.
Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
a6af332048 |
SAFETY-48: what the lead cap actually does to a frozen integrator, and what the peak figure depends on
checks / unit (pull_request) Successful in 7m55s
Four review findings, none of them in executable code. The control law, the tests and the instruments' arithmetic are untouched; every number below was re-measured against the committed 16-day capture before it was written down. R1 - app/control.py carried a justification the decision record and MUTATION.md habit 22 had already retracted, and it was false about the code it sits in. It said an unconditional placement "would also pull the integrator toward a command the SATURATION freeze is pinning", priced at 118 of 256 250 ticks. The 118 was measured against a different pair; on the pair the sentence names the two forms are bit-identical - 0 of 256 246 ticks, re-measured. And the narrow form that shipped DOES move a saturation-frozen integrator: it runs before the freeze block and is not gated on `frozen`. Of 79 160 frozen ticks the cap changes `i_w` on 1095, and on 679 of those it moves it further out on the side it was already on - putting back magnitude the freeze had just let fall, which the freeze's own rule forbids. Worst case 2424 W, at prev_w -3400 W, grid +4697 W, actual -4144 W, sat_count 2 -> 3: the freeze leaves the integrator at -176 W and the cap drags it to -2600 W. It never overrides a same-cycle refusal (the freeze clipped on 75 512 ticks, the slew bound on none of them), and that is stated too. It is also where SAFETY-13's settle values went: gating the cap on `not frozen` puts test_control.py part 5 back at -1190 W exactly, while part 4(b) does not come back - that one moved for the winding reason. R3 - the record read its own sensitivity table backwards. `fit_plant()` picks lag 7.5 s on battery-power RMS, which separates it from 2.5 s by 0.3 %, while the tool's own printed fidelity measure (export against the recorded 29.43 kWh) prefers 2.5 s by the whole 35 % gap. Swept properly: at every lag <= 5.0 s release/1.0's worst quarter is ALREADY 3434 W and this card changes it by exactly zero. The 3739 -> 3434 W headline exists at one plant. New section 3a carries the table; the export reduction now leads every summary and the peak is presented as lag-dependent. The form-A rejection is strengthened rather than weakened: form A is worse on the billed quarter at every lag where release/1.0 produces a peak at all, and at every top-N cut of the quarters. R2 - DOCS.md stated modelled watts to the owner as measurement. It now leads with the export reduction, says the figures are simulated, and says plainly that no capacity-tariff improvement is promised. R4 - tools/slew_sim.py --slew narrated "the OVER-ABSORPTION does not move, and at the slowest slews it is slightly WORSE" while printing a monotonically falling column. That sentence is TRUE on release/1.0 (reproduced: 958/1107/1133/1058/987/1029/1150/1143/1081) and false under this branch's law (777/734/663/563/553/507/435/358/321), so SAFETY-39 is not retracted: its record gets a forward reference, and the script now reads SLEW_LEAD_STEPS out of the law it imported and narrates from the column it just printed. Both branches of that narration were driven. R5 - three counts in the L table were decoration and are re-driven in the CI image on a `cp -a`, purged, `:ro`, one file at a time: L5 is 5+5 with the function names exchanged and 5+4 with the branch bodies exchanged (two mutations wearing one name, now listed separately), L6 is 6+3. The separable- state count is grid-dependent and three sweeps disagree, so all three are quoted with their grids and the load-bearing claim is WHERE they separate. R7 - "a large import answered too weakly" is not what the aggregate shows. Form A cuts import by 5.45 kWh and export by 5.18 kWh, and paired per tick delivers 8.56 kWh less offtake energy on the ticks release/1.0 was importing. The harm is a tail redistribution inside quarters that already net to offtake. The conclusion stands; the sentence is narrowed to it. Verified: the full suite in the CI image, purged tree, `:ro` mount, one file at a time, exactly the command in .gitea/workflows/checks.yml - 30/30, exit 0. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
03ef61fa3b |
SAFETY-48: the slew step ceiling reaches the integrator, and what it bounds is the LEAD
`compute()` freezes the integrator with an asymmetric rule and the comment beside it states the requirement outright - "the requirement is that the INTEGRATOR stop accumulating, not only the command" - but `frozen` is computed from ONE signal, `abs(prev_w - actual_w) > saturation_w`, and slew-limiting never enters it. The integrator moves `gain * error` a cycle and the command moves at most `slew_w`, so the integrator outruns the command whenever `|error| > slew_w / gain`: 667 W at the live shape, against a measured median grid error of 1114 W at the onset of a recorded episode. SAFETY-39's retune made it MORE frequent, not less - a smaller step is a lower threshold. ⚠️ THE FORM THE CARD ASKED FOR RAISES THE BILLED QUANTITY, WHICH IS WHY IT IS NOT WHAT SHIPPED. Reusing the asymmetric freeze on a carried slew flag was built from release/1.0's own source and measured over 16.00 days / 256 252 meter instants of the live install's recorder: export 39.61 -> 34.43 kWh, and the worst quarter-hour average OFFTAKE 3739 -> 3935 W with the mean quarter +2.73 W, in five of six plant and tuning variants. A frozen integrator stops at `prev + gain*error`, which undershoots by (1 - gain); for an export that is free and for an import it is offtake, for as long as the ramp lasts. The card said "do not invent a second rule"; the measurement says to, and both sentences are recorded. WHAT SHIPS BOUNDS THE LEAD AT ONE SLEW STEP, inside the branch where the slew actually bound. Same 16 days, same ticks, same disturbance, same plant, same seed: export 39.61 -> 34.07 kWh, wasted throughput 4.67 -> 3.19 kWh, battery sign reversals 2992 -> 2770, median recovery 232 -> 199 s, p99 849 -> 850 s, max 901 -> 898 s, unrecovered 53 -> 31, worst |i_w - prev_w| 9200 -> 800 W - and the worst 15-minute average offtake 3739 -> 3434 W, i.e. the billed quantity IMPROVES. `i_w = slewed` (a cap of zero) is better again at 32.02 kWh and is refused: it is the velocity form this module's docstring says `i_w=None` collapses to. TWO COMMITTED NUMBERS MOVED, DELIBERATELY, WITH THE REASON BESIDE THEM. SAFETY-13's released command settles at -800 W and -1200 W where release/1.0 settled at -1190 W and -2390 W, because there is less wound integrator to settle onto; AC 4's property - it stops at the frozen integrator, not the rail - is what is asserted and the second is now graded against `i_w` rather than a literal. And SAFETY-39's "the slew does not own the over-absorption" is now FALSE - INVERTED, on the independent first-order plant test_control.py writes itself: 1005/1109/1285/1330 W rising with a slower slew becomes 729/550/424/326 falling. Two plant models that share nothing agree on the sign. Evidence: `tools/replay_recorded_loop.py` plus the read-only capture it made (scenarios/loop-2026-09-02_2026-09-17). The "before" law is the shipped file with the block removed by a named substitution - never a transcription - and a missing anchor is a REFUSAL carrying "NOTHING HAS BEEN MEASURED". The instrument prints its own fidelity first: it reproduces 39.6 kWh of export where the install exported 29.4, i.e. it is ~35 % pessimistic about the loop's tracking, so only the delta is claimed. 30/30 suites green, including test_control.py's exhaustive i_w=None equivalence sweep against the transcribed release/1.0 law, untouched: the cap moves `i_w` and not `target`, and that sweep compares (target_w, sat_count, frozen, reason). Six law mutations, one instrument battery. L4 - the cap applied unconditionally, -92 B - was a SURVIVOR of all thirty files: it is bit-identical on the shipped configuration (0 of 256 246 ticks) and separable on 2050 of 257 400 swept states, all at `integrator_max_w` above `max_w`, which part 4 now drives. L5 and L6 are ZERO BYTES. AND TWO COMMENTS IN THIS CARD WERE INVENTED AND ARE CORRECTED IN PLACE. The one-sided spelling was justified by a two-sided form that would "drag a trailing integrator" - it does not, and the two agree on 205 920 of 205 920 swept states; and a "118 of 256 252 ticks" figure had been measured against a different pair. MUTATION.md gains habits 21 and 22 for both shapes. NOT DEPLOYED, NOT VERSIONED. The live install still runs release/1.0's law. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
b548525d10 |
TEL-10: the loop's integrator stops being invisible
`self.i_w` has been a separate quantity from the command since SAFETY-04 and has left the process nowhere at all - no entity, no MQTT attribute, no log line. The investigation behind SAFETY-48 could only RECONSTRUCT it from the grid trace plus a replay; the reconstruction reproduced about a third of the engagements it was checked against and was discarded, so the card it was gathered for had to be argued from a measurement nobody could stand behind. It could not have been made to work either: `i_w` depends on every cycle before it, including the ones where the arbiter overrode the loop and `main.py` re-seeded `self.i_w = self.target`, and that re-seed is invisible in the grid trace. THREE SITE ROWS, APPENDED AFTER release/1.0's EIGHT. `loop_i` is `Decision.i_w` - the accumulator after the cycle, before the output clamp, the slew limit and quantisation. `loop_lead` is `decision.i_w - prev_w` against the command `compute()` was HANDED, which is not a subtraction of the other two published rows: `Setpoint` is the arbiter's output and is this cycle's, so on any cycle the arbiter overrode the loop the two differ - and that is exactly the cycle on which the integrator was re-seeded. `loop_reason` is `compute()`'s own word; the arbiter's `explain()` prints the winning claim's NAME and has never carried the claim's reason, so `slew-limited` appears in neither the `Why` row nor `Controller status`. Measured on the same cycle: arbiter `'loop -> -5000 W'`, loop `'i-clamped'`. NOTHING IN THE CONTROL PATH MOVED. `app/control.py` is not in this diff. `compute()`, its returned `Decision` and every constant it reads are identical to release/1.0, and all nine of release/1.0's retained discovery messages are byte-identical and still FIRST in the announcement. Evidence: 30/30 suites green in the CI image. Nine mutations, ONE survivor, reported as one: `decision.i_w - self.target` for the lead is +2 B and green because `cycle()` has not reassigned `self.target` at that line - the name is kept for the coupling, not for a behaviour it buys, and M2b (+8 B) is the mutation that does change the value and is red. AND TWO OF THIS CARD'S OWN CHECKS COULD NOT REACH THE FAILURE THEY NAMED. "the published integrator reaches its bound" was GREEN under the card's named mutation (publish `prev_w`, -3 B), because the command reaches the bound too - twelve cycles later. It asserts the LEAD TIME now and is red on 5. "a stopped controller publishes not-running" was GREEN under deleting that branch's assignments (-45 B, -67 B), because the fixture STARTED stopped and `__init__` writes the same values; it stops the controller part-way through a run that has already wound the integrator to -5000 W. Both are MUTATION.md habit 4, found by the battery rather than by review. No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading that is not config.yaml's `version:`, and opening one would mean taking a packaging decision this card does not get to take. The operator account is in DOCS.md and the release note belongs to the next PKG ticket. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e3ccd9f6ea |
SAFETY-47: what a shadow run can show, and the watts on its status row
checks / unit (pull_request) Successful in 7m48s
Not a leak and not a write-path defect. Shadow mode's safety is intact -
the substitution, the re-seed, the authorisation gate and the clamp are
untouched. What was wrong is what three merged documents SAY a shadow run
can show you, and a number on the status row that can be 6.61x what a live
controller would command.
SHADOW MODE CANNOT SURFACE A CLOSED-LOOP DEFECT, AND THE DOCUMENTS NOW SAY
SO. The battery is held at 0 W and the carried command is re-seeded to it,
so every measured input - the meter, the billed-quarter accumulator behind
it, the battery power, the SoC - describes a plant that did not respond. A
closed-loop defect is one whose stimulus IS that response. This is the same
property that makes shadow mode safe, so it is not a gap to close later:
the closed-loop answer comes from the closed-loop rig or from a live run.
SAFETY-10 §5 already conceded this for the grid-following loop. It was
never the loop leg's limitation; it is the general case.
THE "STRATEGIES ARE UNAFFECTED" EXEMPTION WAS TRUE UNTIL SAFETY-45 MERGED,
ONE COMMIT EARLIER. That card sizes the buy leg as min(asked, headroom)
with headroom = (900/remaining) x (ceiling - projected), and `projected`
reads the open quarter's accumulator - the meter - which is a function of
what the battery did earlier in that quarter. Measured on TEST-23 stage 3
at peak_cap_w 1500 / house 1200 / max_w 2000, one hour at 5 s:
SAFETY-45's limit cycle NOT visible. 28 onsets live vs 1; grid
-455.5..+3200.0 W vs flat at the 1200 W house;
guard engaged 410/720 cycles vs 0/720.
SAFETY-46's SoC churn NOT visible. The SoC moves 0.000000000 pp.
TARIFF-14's wrong hour VISIBLE, and it is the only one: which hour, at
what price, clearing what spread - identical on
720 of 720 charging cycles at a binding cap.
The exemption narrows to exactly what survives: WHICH hour a strategy picks
and WHY are unaffected; HOW HARD it trades is not. The peak guard's ceiling
and reasons are worth reading from a shadow run; its ENGAGEMENTS are not.
THE NUMBER IS CAVEATED, NOT RE-COMPUTED, AND THAT IS THE DECISION. The
arithmetic is not wrong - 900/remaining is correct for a meter genuinely
under the ceiling, and in shadow the meter genuinely is. It is the right
answer to a question nobody asked. Both surfaces now introduce the watts as
what would have been commanded ON THIS CYCLE, in every state, and carry
shadow.SIZED_FROM_METER whenever a measured billed quarter sized them.
Rejected, and recorded in the decision doc: re-computing it (the recorded
decision would no longer be the decision the shipped path reached, while the
arbiter, clamp, SAFETY-28 gate, log and MQTT all ran on the real one - a
second controller everywhere except the wire); recording nothing (blanks the
row exactly when arbitrage is trading, and the log's edge key is the watts);
and recording the unsized ask beside it (a second number, no warning, and at
the shipped 3500/2000 both figures read 2000 W).
"UPPER BOUND" AND NOT "SMALLER", AND THE DIFFERENCE WAS MEASURED. Charging
only adds offtake, so the shadow size is >= the live size with EQUALITY at
the start of every quarter. Pairwise over 3600 charging cycles in five
configurations: 0 below, 730 exactly equal. The first draft said "smaller",
which would have been false on every one of those 730.
AND THE PREDICATE IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED. arbitrage's
own sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" only when the
headroom came out below the ask - in a shadow run, the START of the quarter,
where the two runs agree to the float. By the end, 900/remaining has
multiplied the headroom past the ask, the trade is not capped, the sentence
is silent, and the record is at its most wrong. A caveat keyed on it would
be quietest exactly where it is needed loudest.
SAFETY-10 §6's COMMITTED EVIDENCE COULD NEVER HAVE FAILED, FOR TWO
INDEPENDENT REASONS, AND CLOSING EITHER ALONE CLOSES NOTHING. Its fixture is
peak_cap_w 15000 against a 350 W house, so the guard never engages and the
sizing is inert - the harness's own comment says so. AND every identity row
reads the FIRST charging sample, where at elapsed=0 the projection IS the
held level and the two runs agree to the float even at a cap that does bind.
Measured: widening the fixture alone leaves that comparison passing. That
second reason is a new shape for MUTATION.md's habit-4 list - an INDEX, not
a fixture - and it is recorded there as the twelfth instance. §6 is re-taken
at a binding cap across the whole run: 716 of 720 charging cycles differ,
headroom 300.0..54000.0 W in shadow against 299.9..307.8 W live, recorded
-2000.0 W against a live -302.4 W.
THE GRADER IS test_arbitrage.py PART 3d, beside SAFETY-45's own closed-loop
regression and built on the same s45_loop() harness, so the runs differ in
one argument. Three lines stand in for _write_unit()'s substitution and
_shadow_settle()'s record and re-seed, marked as a transcription;
test_clamp.py part 8 remains the check on the shipped placement. The section
carries its own precondition into every check: a mutation that stopped
either run trading made it raise on its first min(), kill the file and
report ZERO reds - FCST-06's shape, driven rather than imagined.
AND THE FIX'S OWN FIRST DRAFT CARRIED THE SAME DEFECT. Deleting the caveat
from the action-log line left all 29 files green, because the sentence was
an f-string inside _shadow_settle() and the only suite that drives it uses a
meter_source:off fixture where no arbitrage decision exists. It is
shadow.log_line() now, for the reason words() is a function.
14 mutations, no survivors; M13 and M14 are +0 B and were confirmed on disk
by sha256 with every run purged. M14's first form was aimed at the wrong
direction and correctly survived - min->max makes the shadow record larger,
which is still an upper bound. All 29 check files green.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
8fa4febfef |
SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside while it was happening, and each was paid for at the meter first: SAFETY-45's 28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain 310 Wh. There was no way to watch what the optimiser WOULD do without letting it do it. `shadow_mode` runs strategies, arbiter, clamps and guards, records the decision with its reason, and commands nothing. ⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary single writer. The inverter holds its last command forever - it has no meter timeout - so "commands nothing" implemented as "stops writing" would leave whatever was standing when shadow mode came on standing for as long as it was left on, under a page saying nothing is being commanded. That is the failure this repository keeps finding. Refreshing 0 W is also what firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going quiet would keep that board tripped for the whole run, which is an alarm being used as a mode. ⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its own. It is a substitution inside Controller._write_unit() - the single choke point every write already reaches - in the same form as the three above it, and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still grade the number the decision path produced. ⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The Supervisor composes options as {**config.yaml defaults, **stored user options}, so a new key with a new default reaches EVERY EXISTING INSTALL on the next update - including the one regulating a real battery. A boolean default-on would have stopped it silently. There is no mechanism by which one key can default differently for a new install and an existing one, so "default-on for new" is a value the add-on RESOLVES: `auto` is shadow while control is STOPPED and live once it is STARTED. A fresh install ships `auto_start: false` and comes up observing; an install that is controlling is started and does not change by one watt. THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision they would disagree with a meter that never saw it and LATCH A TRIP THAT SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate (SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation (SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch, because their evidence is measured power. The operator stop is the one deliberate change: enforced at the wire rather than as a P_SAFETY claim, which would otherwise make every recorded decision read "stopped". ⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what stands on the wire, which makes the exit safe by construction - and therefore the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow run answers "what would it command now", not "what would it have done next". The strategies are unaffected; all three defects above are visible from one. Graded on the writes and on the rendered surface, never on the flag: 22 mutations, no survivors, including one that lets a write escape and one that goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig, same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %; shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage decision is identical in action, instant, signed power, reason and arbiter winner. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |