SAFETY-02: a loop can be fresh, tracking and inside its rating and still push the wrong way
The stale-input watchdog asks whether the meter is still talking. The saturation freeze asks whether the inverter can follow. The output clamp asks whether the number is too big. A loop can pass all three while charging the battery out of the grid, because the only thing wrong is the sign. On 2026-08-20 a commercial controller did exactly that four times in one day, for up to 77 minutes at a stretch, reaching a commanded -14 768 W against a ±5000 W inverter. app/watchdog.py compares the emitted setpoint against the authoritative P1 figure and, when they oppose each other with both over 300 W for 180 s continuously, files a failsafe SET claim at P_SAFETY, commands 0 W and latches there until an operator starts control again. Validated against that day rather than against an argument: sim/replay_sign.py in the infra repo drives this module over the committed captures of both 2026-08-20 and the healthy 2026-08-23 and reaches 18 trips on the fault day - every one inside a window NOTES.md §4.7 accounts for - and 0 on the healthy day. The four episodes do share one signature: 0.3 / 0.9 / 10.5 / 0.0 % sign agreement inside them against 92.9 % healthy. Three decisions the ticket could not make: - It is DISARMED whenever the grid-following loop is not what is driving. Sign agreement is a property of a loop that follows the meter, and a maintenance grid charge opposes the meter by design - 2500 W of charge into a house drawing 500 W is +3000 W on the meter against a -2500 W command, for hours. The gate tests the emitted number, not the winning claim's name, because a limit claim can let the loop "win" and still replace its value. - The trip LATCHES. Commanding 0 W removes the command side of the comparison, so the disagreement always clears the moment the trip works. - sign_disagree_w at or above max_w is refused at startup. The arbiter never lets a command exceed max_w, so such a threshold leaves the watchdog incapable of firing while the status page still reports it armed. What it does not catch, said out loud: an inverter that ACTS opposite to its command moves the meter further the same way, leaving command and meter in agreement. That is the saturation freeze's job. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
This commit is contained in:
co-authored by
Claude Opus 5
parent
35856a73ae
commit
9aed43990b
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.4.0"
|
||||
version: "0.5.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
@@ -93,6 +93,27 @@ options:
|
||||
cycle_floor_s: 15
|
||||
auto_start: false
|
||||
|
||||
# --- SAFETY-02 sign-disagreement watchdog ----------------------------------
|
||||
# Trips when the emitted setpoint and the P1 net figure point OPPOSITE ways,
|
||||
# both over sign_disagree_w, continuously for sign_disagree_s. Action: 0 W and
|
||||
# a failsafe that latches until an operator starts control again.
|
||||
#
|
||||
# Both defaults are measured, not chosen. On the captured healthy day
|
||||
# (2026-08-23) the longest legitimate opposed run - a load step the loop has
|
||||
# not caught up with - is 30 s, and sign agreement over the gated samples is
|
||||
# 92.9 %. On the captured fault day (2026-08-20) the four episodes run 0.0-11 %
|
||||
# agreement with opposed runs up to 1752 s. 300 W / 180 s sits in the middle of
|
||||
# a very wide gap: at 60 s the healthy day still trips nothing, at 300 s the
|
||||
# fault day still trips 13 times. There is no reason to move either number
|
||||
# without a capture that says so. They are options because the AC says
|
||||
# thresholds are defaults rather than constants - not because they are knobs
|
||||
# anyone is expected to turn.
|
||||
#
|
||||
# ⚠️ sign_disagree_w must stay BELOW max_w or the watchdog can never fire (the
|
||||
# arbiter bounds the command to +-max_w). validate.py refuses that config.
|
||||
sign_disagree_w: 300
|
||||
sign_disagree_s: 180
|
||||
|
||||
# --- maintenance -----------------------------------------------------------
|
||||
maintenance_enabled: false
|
||||
maintenance_interval_days: 28
|
||||
@@ -155,6 +176,11 @@ schema:
|
||||
cycle_floor_s: int(5,60)
|
||||
auto_start: bool
|
||||
|
||||
# No "off" value, deliberately: this is a P0 safety check and the schema is
|
||||
# not the place to make disarming it a supported configuration.
|
||||
sign_disagree_w: int(50,5000)
|
||||
sign_disagree_s: int(30,1800)
|
||||
|
||||
maintenance_enabled: bool
|
||||
maintenance_interval_days: int(1,90)
|
||||
maintenance_start_hour: int(0,23)
|
||||
|
||||