DEV-02: merge release/1.0, and close the two review blockers
checks / unit (pull_request) Successful in 4m15s
checks / unit (pull_request) Successful in 4m15s
PR #43 was rejected on two findings and had gone unmergeable behind SAFETY-28 and the ALLOC-01 fix. This is the merge commit; the conflict resolution and both fixes are below, because a merge that also changes behaviour has to say so. THE MERGE, AND WHAT IT COST =========================== Two conflicts in main.py, both where SAFETY-28 and this card touched the same method: * `write_setpoint()` split into a site entry point plus a per-unit `_write_unit()` here, while SAFETY-28 put its record gate in the old single-unit body. `write_refusal()` now takes the INVERTER it is about. Asking it with `self.unit` - as release/1.0 does - would authorise A's share on B's wire, and would also trip test_inverter.py part 1's AST scan, which goes red on any read of a Controller N=1 view inside Controller. * the SAFETY-28 gate sits above the clamp and below the non-finite coercion, exactly where release/1.0 put it, and is now asked about `inv`. Fallout the merge produced in the checks, re-aimed rather than relaxed: * every fixture that calls `write_setpoint()` DIRECTLY - the clamp probe, the hung-heartbeat experiment and its serialised counterfactual, the split deadline probe - now arms a real allocation record first. test_inverter.py grows an `arm()` built through the shipped `resolve()`, the same shape test_clamp.py's is: the per-unit envelopes are filed as real `supervised` claims and the site target is their sum, so the water-fill has exactly one answer and the fixture cannot quietly become its own allocator. * test_clamp.py's two-unit failsafe fixture assigned `c.units`, which DEV-02 made a derived property with no setter. It appends a real `Inverter`. BLOCKER 1 - AC 4's ARBITER-BOUND EVIDENCE WAS VACUOUS ===================================================== test_peakguard.py claimed "each unit's `supervised` bound is ITS OWN `max_w` - give inverter B a different rating and the claim filed on inverter B moves with it", and compared B's bound against `_b2.max_w`. `second_inverter()` DEFAULTED B's rating to `LIVE_MAX_W`, which is A's. IT COMPARED (-5000, 5000) AGAINST (-5000, 5000): a number against itself, unable to observe the failure it named. Reproduced: filing the per-unit `device`/`supervised` claims from `self.inverters[0]`'s numbers while leaving `actuator=self.actuator_of(..., inv)` alone left ALL 19 FILES GREEN. At a roster of two with A=5000/B=3000 that makes inverter B's planned envelope (-5000, 5000) instead of (-3000, 3000) - a 2000 W over-command the arbiter believes is supervised. It is a DIFFERENT defect from the actuator variant the static routing pin catches, and only the actuator variant was in the mutation table. * `second_inverter()` gives B 3000 W - a hypothesis, marked as one - for every fixture in the file, so no check there can compare B against A by accident. * the claim is asserted against LITERAL numbers rather than against an expression that can read the same object twice, for `supervised` AND for `device` (whose `dev` had the same defect), plus the envelope the ARBITER RESOLVED for B - a claim filed right and resolved wrong is the same defect one layer down. * a PRECONDITION check fails if the two ratings are ever made equal again. * the BOUND mutation is in the table, beside the actuator one, and was observed RED (3 checks in test_peakguard.py) via tools/mutation_run.sh. ⚠️ THIRD INSTANCE THIS SESSION of a check whose DATA cannot reach the failure it names - ARB-03's call-site scan saw 3 of 8 appends, ALLOC-01's replay generator saw 0 escapes where a widened one saw 39,991. MUTATION.md gains a section for it beside the stale-bytecode and masking ones, and the rule is written at the line: ANY CHECK ASSERTING "X DIFFERS FROM Y" MUST BE RUN ONCE WITH X AND Y ACTUALLY MADE DIFFERENT. BLOCKER 2 - THE LATCH WAS SILENTLY DISARMED BY THE ROLLBACK ROUND TRIP ====================================================================== store.py's rule 2 keeps the flat keys "so a rollback still finds its latch". The operator path that rule contemplates is a ROUND TRIP, and this card lost the latch on it: 1. install migrates -> schema_version=1, unit/inverter-a/... = False 2. operator DOWNGRADES; SAFETY-02 trips inside the downgrade window and the old add-on writes only the flat `sign_tripped: true` 3. operator upgrades again -> `rep.ran` is False, so `_grade_store_migration()` returned early, and `Inverter.__init__` read the namespaced key: False Observed: the controller came up with `sign_wd.tripped = False` while /data/state.json said `sign_tripped: true`. That is store.py's own header sentence - "the file still says sign_tripped: true, the banner is green, and the controller resumes driving the wrong way" - rebuilt by the version marker. A firmware version change with a rollback path was performed on this site on 2026-09-02, so this is not hypothetical. Three changes, each graded by a mutation observed RED: * THE OPERATOR'S CLEAR CLEARS BOTH SPELLINGS. That is what removes the "re-arm forever" objection the `rep.ran` gate existed to answer: with the fossil cleared, `flat True + namespaced False` is unambiguously a downgrade-window latch. * A TRIP MIRRORS THE FLAT PAIR. Rule 2 only ever covered the latch present AT MIGRATION TIME - nothing flat was written for a trip taken afterwards, so an operator who downgraded found `sign_tripped: false` and came up DRIVING. store.py claimed the staleness could only fail toward a SPURIOUS latch. It could not; that sentence is corrected rather than left standing. * THE GUARD RUNS ON EVERY START, and asks the STORE - not the roster - whether anything namespaced is latched. A mirrored trip on B must not re-arm a healthy A, and the store is the right place to ask because it holds every `unit/*/sign_tripped` this install has written, including one belonging to a unit that is not in today's roster. Graded by the three-step scenario itself, run end to end in test_inverter.py part 2, with all three preconditions asserted - including that the catching start did NOT migrate anything, which is what used to skip the guard. Part 2's idempotence check now PRESSES the button instead of hand-writing the store, because the state it used to construct is not one the shipped clear path can produce. Part 3 grades the mirror and the clear on a real roster of two. test_watchdog.py's "the flat key is NOT written" assertion is re-aimed rather than deleted: its argument was right about the READ and wrong about the WRITE. Nothing at runtime reads that key, and the one thing that does ignores it whenever any namespaced latch is set - which a sibling's trip always leaves. What its absence actually cost was the rollback. HANDOVER.md and DOCS.md said the flat key "is never read again", which was the instruction an operator clearing a trip by hand would follow. Both corrected: it is a maintained rollback view, it IS read on every start, and clearing a trip by hand means clearing both spellings. MUTATIONS THIS ROUND, each applied on a purged tree via tools/mutation_run.sh and observed RED: * per-unit `device`/`supervised` BOUNDS from `self.inverters[0]`, actuator left correct -> test_peakguard.py 10g * `_grade_store_migration()` gated on `rep.ran` -> test_inverter.py part 2 * the operator's clear leaving the flat keys set -> test_inverter.py part 2/3 * a trip not mirroring the flat pair -> test_inverter.py part 3 * the guard asking only `self.inverters[0]` -> test_inverter.py part 3 19/19 files green on the merged tree. No hardware was touched. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
@@ -127,6 +127,63 @@ Two rules come out of it, and both are cheap:
|
||||
function, that pair is the first thing to try — TEST-16's two survivors were
|
||||
adjacent lines in one function and neither was individually live.
|
||||
|
||||
## The third way a check lies: its DATA cannot reach the failure it names
|
||||
|
||||
Stale bytecode manufactures survivors from a mutation that never ran. Masking
|
||||
manufactures them from a second guard doing the first one's work. This one
|
||||
manufactures them from a **fixture**: the check runs, the assertion is
|
||||
evaluated, the sentence above it is true — and the numbers it compares are
|
||||
arranged so that the failure it describes could not have changed the answer.
|
||||
|
||||
It is not hypothetical and it is not rare. Three instances in one week, all
|
||||
found by review rather than by a red line:
|
||||
|
||||
* **ARB-03** shipped a call-site scan asserting that every `claims.append` in
|
||||
`cycle()` routes through `actuator_of()`. Its own parse **saw 3 of the 8
|
||||
appends**; the other five were invisible to it and would have passed however
|
||||
they were routed.
|
||||
* **ALLOC-01** shipped a replay generator to hunt for envelope escapes. It found
|
||||
**0**. A widened generator over the same allocator found **39,991**.
|
||||
* **DEV-02** shipped `"each unit's supervised bound is ITS OWN max_w — give
|
||||
inverter B a different rating and the claim filed on inverter B moves with
|
||||
it"`, comparing inverter B's bound against `_b2.max_w`. The fixture defaulted
|
||||
B's rating to A's, so it compared `(-5000, 5000)` against `(-5000, 5000)` —
|
||||
**a number against itself**. Filing both per-unit bounds from
|
||||
`self.inverters[0]` left **all 19 files green**.
|
||||
|
||||
Note what these have in common with a masked rung: the mutation *runs*, and the
|
||||
suite is *honestly* green. Nothing in a purge, a fingerprint or a disassembly
|
||||
can see it, because the code under test really did behave identically on the
|
||||
stimulus it was given. The defect is upstream of the assertion, in what the
|
||||
check was handed.
|
||||
|
||||
**The rule, and it is one line:**
|
||||
|
||||
> **Any check asserting "X differs from Y" must be run once with X and Y
|
||||
> actually made different.**
|
||||
|
||||
Three cheap habits fall out of it, and all three are now used in this repository:
|
||||
|
||||
1. **Write the PRECONDITION as its own check.** `test_peakguard.py` 10g asserts
|
||||
that A and B have different ratings *before* it asserts that B's bound is
|
||||
B's. If a later edit makes them equal again, the precondition goes red rather
|
||||
than the claim going quietly vacuous.
|
||||
2. **Assert against literals, not against the expression under test.**
|
||||
`== [(-_b2.max_w, _b2.max_w)]` cannot distinguish "B's number" from "the
|
||||
number this fixture happens to have twice"; `== (-3000.0, 3000.0)` beside a
|
||||
printed `A = 5000` can.
|
||||
3. **Print what the check saw.** Every one of the three above would have been
|
||||
caught by a human reading one line of output — `supervised bounds by
|
||||
actuator: {'inverter-a': (-5000, 5000), 'inverter-b': (-5000, 5000)}` is
|
||||
self-evidently not evidence of a difference.
|
||||
|
||||
And the mutation-table consequence: **a variant is not covered because a
|
||||
near-miss of it is.** DEV-02's table listed the *actuator* variant of the
|
||||
per-unit claim defect (`device`/`supervised` filed without `inv`), which the
|
||||
static routing pin catches. The *bound* variant — right actuator, wrong
|
||||
numbers — is a different defect with a different fix, and it was absent. Both
|
||||
are in the table now.
|
||||
|
||||
## Where each surface stands
|
||||
|
||||
* **Local and dev-harness runs — the exposed one.** This is where FCST-03 hit
|
||||
|
||||