glenn schrooyenandClaude Opus 5 e663e10245 TEL-04 review: unshadow the helper, validate config at startup, and record
what the rig proved about the age sensor

Review findings 1, 3, 5 and 6. Finding 2 is deliberately untouched - it is
its own ticket.

3. `built` was rebound at test_p1.py:816 by `built = build_source(...)`,
   silently disarming the build() wrapper for anything appended below it.
   Renamed to `sel`. Reproduced the reviewer's failure before fixing:
   appending a check that calls built() after that line gives
   `TypeError: 'HaSignedSource' object is not callable` and aborts at 163 of
   180; with the rename the same probe reaches 180 and passes.

5. DOCS.md now states the "length must equal meter_phases" constraint that
   config.yaml already carried, plus what leaving the list empty actually
   costs: on the surveyed reading the phases carry 2769 W of import while the
   connection nets 187 W, so the tariff quantity is understated ~15x.

6. build_source now checks the ha_signed wiring once at startup instead of
   once per telegram: a blank p1_net_entity, or a phase list whose length
   disagrees with meter_phases, logs an error and disables ingestion. Both
   otherwise fail in the single way indistinguishable from a healthy source
   nobody has fed yet - no samples, a climbing age, the watchdog holding the
   battery at 0 W, and nothing in the log.

1. THE AGE SENSOR. Measured on the ENV-01 rig against the real HomeWizard
   integration, meter frozen via hwsim's `?fault=freeze` seam (cleared in a
   finally:, rig verified restored):

     - websocket state_changed for the meter over 70 s : 0
     - last_reported advanced (REST serialiser)        : no
     - last_reported advanced (websocket serialiser)   : no
     - subscribe_events(state_reported)                : rejected,
       "Event filter is required for event state_reported"

   So Home Assistant exposes NO arrival signal for a repeated reading, and
   the proposed fix - stamp from last_reported via subscribe_entities - is
   not available. subscribe_entities listens only to EVENT_STATE_CHANGED, and
   as_compressed_state carries no last_reported at all.

   The age is therefore "time since the value changed", which on ha_dsmr is
   mostly harmless (a telegram moves several entities) and on ha_signed is
   not: one entity means a healthy meter under a flat load is
   indistinguishable from a dead one. Recorded loudly in DOCS.md, in the
   HaSignedSource docstring and in the CHANGELOG, with the measured 42.2 s
   and 97.0 s gaps from our own capture.

   meter_max_age_s is deliberately NOT widened. The two conditions produce an
   identical signal, so a larger number does not separate them - it only
   chooses which of the two errors you get, and it would disarm the watchdog
   for a genuinely dead meter as well. The honest fix is an arrival stamp the
   meter itself provides.

test_p1.py: 174 -> 179 checks, all green. Other three suites unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-25 17:34:37 +02:00

293 lines
15 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# GoodWe RS485 Controller
Drives a GoodWe ES/BP battery inverter over its RS485 meter bus: holds net grid
exchange at zero, and runs a monthly battery maintenance cycle so the BMS can
balance cells and recalibrate its coulomb counter.
Installers: read `FIELD-GUIDE.md` in the repository. It is not optional reading —
it contains the commissioning gates and the failure modes.
## Before you start
You need:
- A GoodWe **ES / BP family** inverter (AA55 / RS485 meter-bus generation)
- The vendor's meter-emulating controller **disconnected** from the bus
- A T-CAN485 (ESP32) flashed with `firmware/goodwe-master.yaml`
- A grid-power sensor already working in Home Assistant, updating every ~510 s
## The safety model, in short
The inverter **holds its last command forever** — it has no meter-timeout. So:
- The ESP32 commands 0 W if this add-on stops refreshing for ~30 s, and keeps
commanding it.
- This add-on commands 0 W when its inputs go missing, when you stop control,
and when it shuts down.
- The **optional RS485 e-stop** is the only thing that covers this machine
dying. Without it, a failed host leaves the battery latched at its last
command until someone intervenes.
**If anything looks wrong: stop the add-on.** That commands 0 W and the
hardware holds it there.
## Configuration
### Sources
| option | required | meaning |
|---|---|---|
| `meter_entity` | yes | Net grid power. **Positive must mean importing** |
| `meter_invert` | | Flip the sign if the meter reports the other way |
| `soc_entity` | yes | Battery state of charge — use the **ESP32's own read** |
| `batt_entity` | yes | Battery power — again the ESP32's read, `+` = discharging |
| `batt_invert` | | Flip if needed |
| `setpoint_entity` | yes | The ESPHome `number.*_goodwe_setpoint_w` |
Use the ESP32's readings rather than the inverter's cloud or dongle sensors:
those serve cached values, and a stale reading here ends the maintenance charge
phase having charged nothing.
### P1 meter ingestion
`meter_entity` above expects one signed sensor, which usually means a template
someone wrote by hand. Setting `meter_source` moves the whole derivation into
the add-on, where it is done once and tested, and replaces `meter_entity`
entirely.
Which mode you want depends on what your P1 reader publishes, and there are two
shapes in the wild:
- **Two unsigned registers**, consumption and injection, which is what a Belgian
P1 read over DSMR gives you → `ha_dsmr`, or `mqtt_p1` for a bridge. The add-on
subtracts them.
- **One signed figure**, positive = import and negative = export, which is what
a HomeWizard P1 gives you (`sensor.p1_meter_active_power`) → `ha_signed`. The
add-on splits it. `ha_dsmr` **cannot** read this: it wants two registers and
rejects a negative one outright, which is every exporting telegram.
Either way, do not build the missing shape out of template sensors. The point of
`meter_source` is that the sign convention is derived in one tested place rather
than in YAML nobody reviews underneath a safety input.
| option | default | meaning |
|---|---|---|
| `meter_source` | `off` | `off` keeps `meter_entity`. `ha_dsmr` subscribes to the DSMR integration over the HA WebSocket; `mqtt_p1` reads a topic; `ha_signed` subscribes to one signed entity over the HA WebSocket |
| `meter_phases` | 1 | 1 or 3. Must match the telegram, or every telegram is rejected and logged |
| `meter_max_age_s` | 30 | Beyond this the reading is stale and grid power reads as *missing*. On its own it does **not** command 0 W — see the timing note below. It is also the longest a reading is held forward into the 15-minute average |
| `meter_mqtt_topic` | | `mqtt_p1` only |
| `p1_import_entity` | | The **unsigned** consumption sensor. Do not point this at a signed template |
| `p1_export_entity` | | The **unsigned** injection sensor |
| `p1_phase_import_entities` | `[]` | L1..L3, in order. Needed for the capacity-tariff peak on a three-phase connection |
| `p1_phase_export_entities` | `[]` | L1..L3, in order |
| `p1_net_entity` | | `ha_signed` only. The **signed** net-power sensor: `+` import, `-` export |
| `p1_phase_net_entities` | `[]` | `ha_signed` only. L1..L3, in order, each signed the same way. Needed for the capacity-tariff peak on a three-phase connection. **The list length must equal `meter_phases`** |
Both per-phase lists are checked against `meter_phases` **once at startup**: a
list of the wrong length disables P1 ingestion with an error in the log, rather
than letting every telegram fail its phase-count check one at a time. Leaving
the list empty is fine and is not an error — you simply get no per-phase
figures, and therefore no capacity-tariff peak. On a three-phase connection
that is a much bigger omission than it looks: on a surveyed reading here the
phases carried 2769 W of import while the connection netted 187 W, so the
billed quantity is understated roughly fifteenfold if the phases are missing.
#### How long a dead meter takes to reach 0 W
`meter_max_age_s` and `stale_input_s` **stack**. They are two different clocks
and neither one is the whole answer:
| step | option | default |
|---|---|---|
| telegrams stop, P1 sample goes stale, grid power starts reading *missing* | `meter_max_age_s` | 30 s |
| inputs have been missing long enough for the loop to command 0 W | `stale_input_s` | 15 s |
| **total, meter death → 0 W commanded by this add-on** | | **45 s** |
So in P1 mode `stale_input_s` is *not* "how long inputs may be missing before
commanding 0 W" measured from the meter dying — it is measured from the moment
the P1 sample already went stale. Size the pair together: the ESP32's own
watchdog commands 0 W after ~30 s of silence from this add-on regardless, and
that layer is unaffected by either option.
There is **no fallback to an inverter-side power figure**, deliberately. The
inverter's own AC power tracks its battery almost perfectly and the real meter
hardly at all, so a controller that failed over to it would be regulating
against its own output while looking healthy.
The `mqtt_p1` payload is one JSON object per telegram, and the schema is strict —
a key it does not recognise is a telegram from something other than what was
tested, and guessing a key here means guessing a kilowatt:
```json
{"import_w": 1234.0,
"export_w": 0.0,
"phases": [{"import_w": 500, "export_w": 0},
{"import_w": 400, "export_w": 0},
{"import_w": 334, "export_w": 0}],
"timestamp": "2026-08-24T18:00:05+02:00"}
```
`phases` and `timestamp` are optional; `timestamp` must carry a UTC offset. Where
it is present it is used for the age, which is what stops a retained message
replayed on reconnect from presenting a ten-minute-old reading as current.
#### `sensor.p1_sample_age_s`
Published over MQTT discovery whenever a broker is available: **seconds since the
newest accepted telegram**, refreshed every second rather than only when a
telegram lands. The ESP32's stale-input watchdog subscribes to this exact entity
id, so do not rename it.
The reason it is recomputed against the clock is that Home Assistant only pushes
a state when the state *changes*. A meter sitting at a genuinely constant reading
emits nothing, which is indistinguishable — to anything watching the value — from
a meter that has died. Watching the age instead separates the two: it climbs when
telegrams stop and resets when they arrive, whatever the reading says.
The entity is only created when `meter_source` is not `off`. With P1 ingestion
disabled there is nothing feeding it, and an age sensor climbing with no ingester
behind it would trip the firmware watchdog on a system that is working fine.
> **Known limit, `mqtt_p1`.** The age measures *arrival*. On the MQTT path a
> bridge that is stuck republishing its last telegram keeps arriving, so the age
> stays near zero and a frozen meter still looks fresh. Detecting *that* needs a
> change-detector rather than an arrival-detector, and it is not in this version.
> ⚠️ **Known limit, `ha_signed` — do not drive a watchdog off this age yet.**
> On the HA WebSocket paths the age is stamped when a `state_changed` arrives,
> which means it measures *time since the value last changed*, not time since
> the meter last reported. Home Assistant offers nothing better: a repeated
> reading produces no `state_changed`, does **not** advance `last_reported` on
> either the REST or the WebSocket serialiser, and `state_reported` cannot be
> subscribed to over the WebSocket at all (`Event filter is required for event
> state_reported`). All three measured on the ENV-01 rig against the real
> HomeWizard integration with the meter frozen: 0 `state_changed` in 70 s and no
> timestamp movement anywhere.
>
> `ha_dsmr` mostly escapes this because a DSMR telegram updates several entities
> and something in the set almost always moves. **`ha_signed` has exactly one
> entity, so a healthy meter under a flat load is indistinguishable from a dead
> one.** This is not hypothetical: in our own captures
> (`sim/scenarios/ha-p1_meter_active_power-2026-08-20.json`) the real house meter
> went **42.2 s and 97.0 s** between changes, and 23 Aug peaks at 29.1 s — all
> past the default `meter_max_age_s` of 30.
>
> So `sensor.p1_sample_age_s` on `ha_signed` is safe to *read*, and it is
> correct whenever the value is moving, but it must not yet be thresholded by
> the ESP32 stale-input watchdog: a quiet house would trip the battery to 0 W.
> Raising `meter_max_age_s` is **not** the fix — the two conditions produce an
> identical signal, so a bigger number only chooses which of the two errors you
> get. The real fix is an arrival stamp the meter itself provides, i.e. reading
> the HomeWizard local API directly rather than through an HA entity.
### Control
| option | default | meaning |
|---|---|---|
| `max_w` | 2000 | Hard limit on what may be commanded. Start low, raise after commissioning |
| `gain` | 0.6 | Correction per cycle. **At the limit — do not raise** |
| `slew_w` | 1000 | Maximum change per cycle |
| `deadband_w` | 15 | Ignore errors smaller than this |
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
| `step_w` | 10 | Quantisation |
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one *changed* meter reading, not a fixed period - see the note below. **Do not set to 1** |
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W. In P1 mode this clock starts only *after* `meter_max_age_s` has already expired — the two stack, see "How long a dead meter takes to reach 0 W" |
| `auto_start` | false | Start controlling on boot (only after commissioning) |
#### Saturation is counted in cycles, not seconds
The specification states the saturation window as **"> 10 s"**. This add-on counts
**cycles** instead, and that is a deliberate, accepted deviation rather than an
oversight - the acceptance criterion is not met as literally written.
A cycle here is one *changed* meter reading: the controller only runs the loop when the
meter value differs from the previous poll. At the reference P1's ~5 s update rate the
default of 3 cycles is usually around 15 s, but there is **no guaranteed wall-clock
window** - a meter that repeats the same value stalls the counter for as long as it
repeats.
Two reasons that is acceptable:
- the control law is a pure function with no clock, which is what makes it testable
without hardware, and a seconds-based window would have to live in the controller;
- a stalled counter is a detection-latency limit and not a runaway risk. The condition
that stalls it - an unchanging meter - stops the whole loop, so nothing accumulates
while it is stalled.
If a guaranteed window matters on your site, raise `saturation_cycles` for a fast meter,
and treat the figure as "N meter updates" rather than "N seconds".
#### Why `target_grid_w` is not zero
The deadband is a one-way ratchet: any resting point inside it holds until
something disturbs it. Import and export are **separate registers on the
meter**, so a rest point of +14 W is billed for every second it holds and no
amount of export cancels it - 14 W all day is 0.34 kWh.
Biasing the target below zero moves that residue into the export register,
which is not billed. The resting band becomes `target ± deadband`, so:
| `target_grid_w` | resting band | worst billed leak | export given away |
|---|---|---|---|
| 0 | -15 … +15 W | ~15 W (0.35 kWh/day) | none |
| **-10** | -25 … +5 W | ~5 W (0.12 kWh/day) | ~10 W |
| -15 | -30 … 0 W | none | ~15 W (0.36 kWh/day) |
Set it to `-deadband_w` if injection is worth nothing to you and you would
rather give the energy away than buy it back. Set it to `0` if you are paid
properly for export, or if you are debugging and want the loop centred.
⚠️ This is a **billing** knob, not a speed knob. If import is arriving in
bursts rather than as a trickle, the cause is tracking lag, and this will not
help - see "Why the tuning is what it is".
### Maintenance
| option | default | meaning |
|---|---|---|
| `maintenance_enabled` | false | Enable the monthly cycle |
| `maintenance_interval_days` | 28 | Minimum gap between cycles |
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
| `maintenance_discharge_w` | 2500 | Drain rate (exports the surplus) |
| `maintenance_charge_w` | 2500 | Charge ceiling, capped again by peak headroom |
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor |
| `maintenance_soc_target` | 99 | Charge target |
| `maintenance_hold_min` | 120 | Hold at full so the BMS can balance |
### Tariff (all optional)
| option | meaning |
|---|---|
| `peak_forecast_entity` | Quarter-hour demand forecast, for capacity-tariff markets. Empty = no cap |
| `peak_cap_w` | The site's capacity-tariff target |
| `price_now_entity`, `price_avg_entity` | Dynamic tariff. Empty = never force a paid grid top-up |
On a capacity-tariff site the maintenance charge is capped by the headroom left
under `peak_cap_w`, and if the forecast goes over the cap the charge-only clamp
is dropped so the battery can shave the peak instead. Money outranks the
maintenance schedule.
### Site
| option | meaning |
|---|---|
| `estop_fitted` | Whether the RS485 e-stop is installed. Drives the warning banner |
| `log_level` | `trace`/`debug`/`info`/`warning`/`error` |
## The Web UI
The ingress panel shows live values, why the controller is commanding what it
is, and a **Commissioning** checklist that names any problem in words. It also
carries the three buttons: start/stop control, force a maintenance cycle, and
abort one.
## Status entities
If an MQTT broker is available the add-on publishes setpoint, grid power,
battery power, state of charge, maintenance phase and controller status by MQTT
discovery. This is observability only — the controller works fine without a
broker, and MQTT problems can never affect control.