TEL-04 and TEL-05 merged without a version bump, so Home Assistant would not have offered the update - the same trap DEPLOY-01 caught at 0.2.1, recurring because merging a feature does not touch the version. ha_signed reads one signed entity. homewizard_local polls the meter's own API, where every HTTP response is a genuine arrival - the property the firmware watchdog needs, and the one HA cannot provide for a repeated reading. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
244 lines
14 KiB
Markdown
244 lines
14 KiB
Markdown
# Changelog
|
||
|
||
## 0.4.0
|
||
|
||
**TEL-04.** `meter_source: ha_signed` reads a single *signed* power entity, which
|
||
is the shape a HomeWizard P1 publishes. Both transports 0.3.0 shipped require two
|
||
unsigned registers and refuse negatives, so neither fits the meter installed here.
|
||
|
||
**TEL-05.** `meter_source: homewizard_local` polls the meter's own local API
|
||
directly. This exists because of something the HA paths cannot do: Home Assistant
|
||
fires no state change for a repeated reading and exposes no arrival signal at
|
||
all, so `sensor.p1_sample_age_s` on those transports measures time since the
|
||
*value changed*, not since the meter *reported*. Real captured data has gaps of
|
||
42 s and 97 s between changes on a perfectly healthy meter - long enough for a
|
||
30 s staleness threshold to command 0 W for no reason. Every HTTP response to the
|
||
local API is a genuine arrival, so the age means what it says.
|
||
|
||
Verified on the rig against a literally constant 350.0 W for 70 s - the exact
|
||
state where the HA path recorded zero samples in 45 s - with 14 arrivals and the
|
||
age never exceeding the poll cadence.
|
||
|
||
Set `p1_host` to the meter's address and `meter_poll_s` (default 5 s, matching
|
||
the meter's own ~5 s update). Still defaults to `off`; nothing changes for an
|
||
install that does not opt in.
|
||
|
||
Freeze detection is separate and deliberately not thresholded: a meter answering
|
||
200 OK with a stale number *is* arriving, so no arrival stamp can flag it. The
|
||
energy registers carry that as `unchanged_s`, surfaced on the status line for a
|
||
human to read rather than alarmed on - at a converged -10 W a 1 Wh register needs
|
||
about six minutes to move, so any threshold would false-trip at the target
|
||
operating point.
|
||
|
||
## Unreleased
|
||
|
||
**TEL-05.** A fourth `meter_source`, `homewizard_local`, which polls a
|
||
HomeWizard P1's **own local API** (`GET /api/v1/data`) instead of watching a
|
||
Home Assistant entity. Set `p1_host` to the meter's address; `meter_poll_s`
|
||
(default 5 s, the meter's own update rate) sets the cadence.
|
||
|
||
✅ **This is the first transport whose `sensor.p1_sample_age_s` measures when
|
||
the meter *reported*, and therefore the first one a firmware watchdog may
|
||
threshold.** Every HTTP response is an arrival: the meter answered, now, with
|
||
its current reading, and whether the *number* moved is not consulted. Home
|
||
Assistant cannot express that at all — a repeated reading emits no
|
||
`state_changed`, advances `last_reported` on neither serialiser, and
|
||
`state_reported` is not subscribable ("Event filter is required"). On
|
||
`ha_signed` that made a healthy meter under a flat load indistinguishable from
|
||
a dead one, and our own capture of this house's meter goes 42.2 s and 97.0 s
|
||
between changes — both past the default `meter_max_age_s` of 30, i.e. a false
|
||
trip to 0 W on a meter that is fine. If you have a HomeWizard P1, move to this
|
||
mode.
|
||
|
||
Everything TEL-01 established is reused, not re-implemented: ingest
|
||
timestamping, `meter_max_age_s`, the clock-recomputed age, the plausibility
|
||
bounds and the §20 unsigned-decode rejection, and the same `split_signed` sign
|
||
convention `ha_signed` uses. A failed or timed-out poll submits nothing, so it
|
||
is a *missing* reading — never 0 W — and it does not reset the age.
|
||
|
||
Verified on the ENV-01 rig against `sim/hwsim.py`, steady and with `--fault
|
||
freeze` injected. Still defaults to `off`.
|
||
|
||
⚠️ **An arrival stamp still cannot see a *frozen* meter**, and no arrival
|
||
detector can: a meter answering `200 OK` forever with a stale number is
|
||
arriving. The local API does expose what the HA path never had — the
|
||
`total_power_*_kwh` registers stop advancing — and the transport tracks it as
|
||
`unchanged_s`, but that is deliberately **not** folded into the age and not
|
||
thresholded: this controller regulates grid power toward ~0 W, and at a
|
||
converged −10 W the export register needs six minutes to move by its 1 Wh
|
||
resolution while the power figure legitimately repeats. Thresholding it at 30 s
|
||
would rebuild the false-trip limit cycle at the exact operating point we aim
|
||
for. Freeze detection needs the low-power case solved first, separately. It is
|
||
shown on the status page's P1 line instead — leaving it unthresholded only
|
||
holds up if a human can read it, so now they can.
|
||
|
||
**TEL-04.** A third `meter_source`, `ha_signed`, reading **one signed** Home
|
||
Assistant entity: positive = import, negative = export. That is the shape a
|
||
HomeWizard P1 publishes (`sensor.p1_meter_active_power`), and it is the meter
|
||
actually fitted here - which neither TEL-01 transport can read, because
|
||
`ha_dsmr` needs two unsigned registers and refuses a negative one, i.e. every
|
||
exporting telegram. Set `p1_net_entity`, and `p1_phase_net_entities` for the
|
||
per-phase capacity-tariff figures on a three-phase connection.
|
||
|
||
Everything TEL-01 established is inherited rather than re-implemented - the
|
||
new transport is a subclass of the `ha_dsmr` one overriding only which
|
||
entities it wants and how they become a sample. So ingest timestamping,
|
||
`meter_max_age_s`, `sensor.p1_sample_age_s` recomputed against the clock and
|
||
republished once a second, the plausibility bounds, and `unavailable` /
|
||
`unknown` treated as a *missing reading and never 0 W* all behave identically
|
||
across the three sources.
|
||
|
||
Still defaults to `off`; an existing install is unaffected until it opts in.
|
||
|
||
⚠️ **`sensor.p1_sample_age_s` is published on `ha_signed`, but must not yet be
|
||
thresholded by the ESP32 stale-input watchdog.** On the HA WebSocket paths the
|
||
age is stamped from `state_changed`, so it measures time since the value
|
||
*changed*, not since the meter *reported* - and Home Assistant exposes no
|
||
arrival signal for a repeated reading (no `state_changed`, no `last_reported`
|
||
movement on either serialiser, and `state_reported` is not subscribable over
|
||
the WebSocket). Measured on the ENV-01 rig against the real HomeWizard
|
||
integration. `ha_dsmr` mostly escapes it because a telegram moves several
|
||
entities at once; `ha_signed` has one, so a healthy meter under a flat load is
|
||
indistinguishable from a dead one. Our own capture has the house meter going
|
||
42.2 s and 97.0 s between changes. Raising `meter_max_age_s` does not fix that,
|
||
it only chooses which error you get; the fix is an arrival stamp from the meter
|
||
itself and is a separate ticket. Full detail in DOCS.md.
|
||
|
||
## 0.3.0
|
||
|
||
**SAFETY-04.** The control law's integrator is now an explicit accumulator,
|
||
bounded independently of the output clamp instead of inheriting whatever
|
||
headroom the clamp happened to leave. It also freezes while the inverter is
|
||
not tracking, rather than continuing to wind up against a command nothing is
|
||
acting on. `integrator_max_w` (default `0`) governs the bound; `0` means
|
||
"follow `max_w`", which is the existing behaviour.
|
||
|
||
Behaviour is unchanged at the defaults - a 4,928-case equivalence sweep
|
||
against the previous control law confirms it decides identically at
|
||
`integrator_max_w: 0`.
|
||
|
||
**TEL-01.** P1 meter ingestion, so a Belgian P1's two unsigned registers
|
||
(consumption, injection) no longer need a hand-written signed template
|
||
sensor: the subtraction moves into the add-on, done once and tested. Two
|
||
transports, chosen with the new `meter_source` option: `ha_dsmr` subscribes
|
||
to the DSMR integration over the HA WebSocket, `mqtt_p1` reads a topic.
|
||
Defaults to `off`, which keeps the existing `meter_entity` path untouched -
|
||
nothing changes for an install that does not opt in.
|
||
|
||
Enabling it publishes `sensor.p1_sample_age_s`: seconds since the newest
|
||
accepted telegram, recomputed against the clock and republished roughly once
|
||
a second rather than only when a telegram lands. That is deliberate - Home
|
||
Assistant only pushes a state on change, so a meter sitting at a genuinely
|
||
constant reading would otherwise look identical to a dead one. Watching the
|
||
age instead means a frozen meter shows a climbing age, not a flat line. The
|
||
firmware watchdog subscribes to this exact entity id.
|
||
|
||
Known limits, both already in DOCS.md: on `mqtt_p1`, a bridge stuck
|
||
republishing its last telegram still "arrives", so the age cannot detect
|
||
that particular failure - prefer `ha_dsmr` where both are available. And a
|
||
dead P1 meter takes 45 s to reach 0 W commanded (30 s for `meter_max_age_s`
|
||
to call the reading stale, then 15 s of `stale_input_s` on top), which is
|
||
`meter_max_age_s` and `stale_input_s` stacking, not either one alone.
|
||
|
||
## 0.2.1
|
||
|
||
`target_grid_w` (default -10 W): what the meter should rest at. The deadband
|
||
holds any resting point inside it indefinitely, and the meter bills import and
|
||
export on separate registers, so resting at +14 W import costs 0.34 kWh/day
|
||
with the loop behaving perfectly. Biasing the target slightly negative moves
|
||
that residue onto the export register. Configurable in the Configuration tab;
|
||
see DOCS.md for the trade-off table.
|
||
|
||
Behaviour is unchanged at `target_grid_w: 0`.
|
||
|
||
## 0.2.0
|
||
|
||
Precedence between strategies is now a first-class object instead of an if/else
|
||
ladder, ahead of there being more than three of them.
|
||
|
||
Every strategy returns a CLAIM each cycle - `set` ("I want X") or `limit` ("the
|
||
result must stay within these bounds") - and `arbiter.py` resolves them by one
|
||
rule:
|
||
|
||
1. Highest-priority `set` wins; no claim at all means 0 W.
|
||
2. Then every `limit` whose priority is >= that set's priority applies, most
|
||
restrictive first.
|
||
3. Contradictory limits are a BUG: command 0 W and say so.
|
||
|
||
Clause 2 is why "money outranks maintenance" is now a consequence of the
|
||
priorities rather than a special case in a Jinja template: the maintenance
|
||
charge-only limit binds the loop, but will not bind a higher-priority peak
|
||
shaving claim when one exists.
|
||
|
||
- Maintenance shaping (charge-only, cheap-window floor) moved out of the control
|
||
law. `control.py` is once again only a controller that tracks the meter.
|
||
- The loop computes from the ARBITER's last output, not its own last wish. If
|
||
something outranked it, that is what the hardware actually did, and tracking
|
||
anything else makes it jump when it regains control.
|
||
- Every decision is explainable: "loop -> 0 W, limited by maintenance
|
||
(charge-only)" now appears in the UI and the log, instead of a bare number.
|
||
- Safety limits (device rating, supervised max_w) bind every strategy including
|
||
the highest, and are still enforced a second time at the point of writing.
|
||
|
||
## 0.1.6
|
||
|
||
Findings from installing this on a live system, replacing a working YAML
|
||
implementation. Every one of these was silent - the add-on looked healthy while
|
||
being completely unable to do its job.
|
||
|
||
- **`run.sh` must use `#!/usr/bin/with-contenv sh`.** The HA base images run
|
||
s6-overlay, which starts services with a SANITISED environment. With a plain
|
||
shebang, SUPERVISOR_TOKEN is simply absent and every Home Assistant call
|
||
returns 401 - while `homeassistant_api: true` makes the permissions look
|
||
correctly granted. Startup now logs the token length and probes the Core API,
|
||
so the next person sees it in one line.
|
||
- **Bump `version:` for every change.** Supervisor keys the built image by
|
||
version, so editing source and rebuilding silently reuses the old image. Two
|
||
fixes appeared not to work because of this.
|
||
- **Dependencies come from apk, not pip.** Alpine is musl and there are no musl
|
||
wheels for aiohttp; pip would compile it on the client's Pi.
|
||
- **paho-mqtt 1.x and 2.x are both supported.** Alpine ships 1.x, which has no
|
||
`CallbackAPIVersion`; that raised and took the whole add-on down with it.
|
||
- **MQTT can no longer take down control.** Publisher construction is wrapped -
|
||
observability must never stop the controller.
|
||
- **MQTT discovery is published from `on_connect`.** paho drops QoS-0 publishes
|
||
issued before the CONNACK, so announcing straight after `connect()` published
|
||
nothing at all while logging "MQTT connected".
|
||
- **Repeated failures log at most once a minute.** The control loop retries every
|
||
second; unthrottled warnings rolled the log buffer and destroyed the startup
|
||
diagnostics needed to debug the 401 above.
|
||
- **`auto_start` works.** The store's defaults supplied `auto: False`, so the
|
||
fallback to the option could never fire.
|
||
|
||
Known issue: after deleting the MQTT entities from the registry during
|
||
development, Home Assistant would not re-adopt them from retained discovery -
|
||
not even after clearing the retained topics and reconnecting. The add-on
|
||
publishes correct discovery and live state (verified on the broker); this is an
|
||
HA-side adoption problem and affects status entities only, never control.
|
||
|
||
## 0.1.0
|
||
|
||
First packaged release. Ports the control loop and the monthly maintenance
|
||
cycle from the reference Home Assistant implementation into an add-on.
|
||
|
||
- Grid-following control: gain/slew/clamp/deadband with anti-windup, all tuned
|
||
against measured hardware behaviour (see FIELD-GUIDE.md §14).
|
||
- Saturation freeze **with the duration term** — three consecutive diverging
|
||
cycles, not one. The instantaneous test fires on every large correction,
|
||
because the plant itself needs 3-6 s to settle.
|
||
- Monthly maintenance cycle as an ownership state machine: drain / charge /
|
||
hold, with exactly one writer of the setpoint at any moment.
|
||
- Capacity-tariff awareness: the maintenance charge is capped by quarter-hour
|
||
peak headroom, and peak shaving outranks the maintenance schedule.
|
||
- Failsafe behaviour: commands 0 W on missing inputs, on stop, and on shutdown.
|
||
Never replays a stale setpoint - the reference implementation did, and the
|
||
hardware watchdog cannot catch that.
|
||
- Ingress UI with a commissioning checklist that names problems in words.
|
||
- Optional MQTT discovery for status entities.
|
||
|
||
Known limits:
|
||
|
||
- Home Assistant OS / Supervised only (add-ons cannot run on Container/Core).
|
||
- The inverter protocol is reverse-engineered; no vendor contract.
|
||
- Without the optional RS485 e-stop, nothing covers the host machine dying.
|