Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive for consumption and negative for production. `pv_invert_entities` lists the ones to flip; the flip is applied per member inside pv.total(), before the sum, so the MQTT `pv` row and the status page carry the corrected figure. Default [] is byte-identical to 0.12.0. Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0): a parallel list validates the 0.12.0 blob unchanged and renders as its own translated repeatable field; dicts on pv_entities refuse 0.12.0's stored strings; a prefix is invisible syntax; a global bool cannot describe a mixed roster. Status page marks flipped entities and cautions per entity below -50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged. Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
354 lines
20 KiB
Markdown
354 lines
20 KiB
Markdown
# TEL-11 — the PV production channel
|
||
|
||
*What was decided, what it was decided against, and what the evidence was.*
|
||
|
||
## 0. The problem, in OPT-10's numbers
|
||
|
||
Over sixteen days at the reference site the pack reached 90 % SoC on **two** of
|
||
them, and **20.5 kWh of surplus left the site while the pack still had room** —
|
||
**12.6 kWh** of it with the battery **not charging at all**. That single
|
||
measurement is upstream of most of what else was found that week: the nightly
|
||
floor, SAFETY-37's misdiagnosis, the SAFETY-57 deadlock, a 2 h 47 min saturation
|
||
freeze.
|
||
|
||
It cannot be **attributed**, because **PV production is recorded nowhere in this
|
||
system**. Three causes need three different fixes:
|
||
|
||
| cause | fix |
|
||
|---|---|
|
||
| there was no irradiance | none — the site behaved correctly |
|
||
| production was there, charge power was limited | a limit, somewhere |
|
||
| production was there, the pack had room, the optimiser declined | **the only software defect** |
|
||
|
||
Guessing between them is how an optimiser gets tuned to solve a cloud problem.
|
||
**This card adds the channel and does not do the attribution.** Ship it, let it
|
||
record a week, OPT-10 picks it up with data.
|
||
|
||
## 1. It is an HA entity, not a register — and that is a product decision
|
||
|
||
The RS485 bus this add-on speaks carries the **battery** inverter it drives. On
|
||
nearly every site the PV inverter is a different box from a different vendor,
|
||
reporting into Home Assistant through its own integration; it is **not** on this
|
||
bus and there is no reason it would be. So the signal comes from an entity:
|
||
`pv_entity` takes whatever `sensor.*` the site's PV integration provides, any
|
||
brand HA can read.
|
||
|
||
Reading a register would have been cheaper on one house and wrong for a fleet —
|
||
the trade [[product-not-one-house]] names.
|
||
|
||
## 2. The sign convention: **positive is production**, and there is no `pv_invert`
|
||
|
||
> Reversed by TEL-14 (flag and negative caution): `DECISIONS/TEL-14-pv-sign.md`.
|
||
|
||
### The convention is derived, not assumed
|
||
|
||
Two sign rules already ship, and both are recorded in `DOCS.md`'s *Sources*
|
||
table rather than inferred here:
|
||
|
||
* `meter_entity` — **positive must mean importing** (`meter_invert` flips it);
|
||
* `batt_entity` — **`+` = discharging** (`batt_invert` flips it).
|
||
|
||
Both are *"positive = power arriving at the house's AC bus"*. Production arrives
|
||
there too, so **positive = producing** is the continuation of the shipped
|
||
convention rather than a fresh choice.
|
||
|
||
### Why an invert flag would be over-building
|
||
|
||
The question is not "could a sensor be reversed" — it could. It is what a flag
|
||
would **buy**, and the answer is nothing, for two reasons that do not apply to
|
||
the two keys it would sit beside:
|
||
|
||
1. **Those two quantities are read by the control path; this one is read by
|
||
nothing.** `inv.batt` feeds SAFETY-30's per-unit sign check and SAFETY-31's
|
||
circulating-power sensor (`_read_unit()`'s own docstring says so), so a
|
||
reversed battery sensor hands the site a plausible number it then **acts**
|
||
on — a latch that trips when it should not, or does not trip when it should.
|
||
`pv_w` reaches no decision at all (§4), so a reversed PV sensor cannot
|
||
mislead one.
|
||
2. **Production is unipolar, so the error is self-announcing.** Battery power
|
||
and grid power are legitimately negative half the time, which is exactly why
|
||
a flipped sign is invisible in them. A PV array does not consume: a reversed
|
||
sensor reads **−4 kW at noon**, in the first day of the very history this card
|
||
exists to create. An invert flag would let an installer *hide* that by
|
||
flipping it to something that looks right, and a second place for the sign to
|
||
be wrong is a second thing to get wrong.
|
||
|
||
So: the convention is documented in `config.yaml`, both translations, `DOCS.md`
|
||
and `app/pv.py`, the value is published **exactly as the sensor reports it**,
|
||
and there is no flag. `test_pv.py` part 1 pins `-8 W` through unchanged.
|
||
|
||
### And no negative-value alarm either
|
||
|
||
The tempting middle path — warn when the reading is negative — needs a
|
||
threshold, because a PV inverter's own standby draw makes a small negative
|
||
reading at night entirely ordinary. Any threshold here would be a number nobody
|
||
measured, in a card whose whole subject is not fabricating numbers. The
|
||
published row is the detector.
|
||
|
||
## 3. Absence is never zero, and it is not "dropped" either
|
||
|
||
This is the constraint that shaped the publication, and the obvious
|
||
implementation fails it.
|
||
|
||
`MqttPublisher.publish()` **skips** a `None` value. That is right for
|
||
`circulation` — its note in `main.py` says a missing per-unit reading should
|
||
leave the last figure standing rather than publish a zero that reads as health —
|
||
and it is **exactly wrong here**: a skipped row leaves Home Assistant holding
|
||
the last number it was told, *forever*, and the recorder then draws a **flat
|
||
line at that value through the outage**. Read back a week later that is
|
||
indistinguishable from a real measurement, and if the last value happened to be
|
||
small it manufactures precisely the *"there was no surplus to store"* conclusion
|
||
the card exists to **test**.
|
||
|
||
So TEL-11 publishes the absence, using Home Assistant's own mechanism:
|
||
|
||
> `homeassistant/components/mqtt/const.py`: `PAYLOAD_NONE = "None"`.
|
||
> `homeassistant/components/mqtt/sensor.py`, in the state-message handler:
|
||
> `if payload == PAYLOAD_NONE: self._attr_native_value = None; return` — and it
|
||
> is tested **before** the numeric branch, so it holds for a row carrying
|
||
> `device_class: power`.
|
||
> (github.com/home-assistant/core, branch `dev`, retrieved 2026-09-24. The
|
||
> shipped MQTT-sensor documentation says the same thing in its `state_topic`
|
||
> entry: *"a 'None' value will set the sensor to an unknown state"*.)
|
||
|
||
The entity therefore goes to **`unknown`** and the recorder stores a **gap**.
|
||
`mqtt.ABSENT_AS_UNKNOWN` is a one-key set and `test_pv.py` part 3 asserts both
|
||
that the pv row gets this treatment **and that `circulation` still does not** —
|
||
widening the rule silently would be a behaviour change to another card's row.
|
||
|
||
⚠️ **What was NOT built, and why.** A per-entity `availability` block
|
||
(`availability_mode: all`, an extra retained topic) would also produce a
|
||
distinguishable state — `unavailable` rather than `unknown` — but it needs a
|
||
second topic, a second retained message, a change to `_payload()`'s
|
||
byte-order-sensitive key construction, and it survives restarts only if the
|
||
retention is right. The payload route is one branch in `publish()` and one
|
||
constant, and it is graded as **bytes on the topic** rather than as a claim
|
||
about HA's availability handling.
|
||
|
||
### Three states, not two
|
||
|
||
| state | frame | wire | page |
|
||
|---|---|---|---|
|
||
| no source (`pv_entity` unset) | no `pv` key | no topic, no entity | no row |
|
||
| no reading | `pv: None` | `goodwe_ctl/pv` = `None` | `PV —` + a caution naming the reason |
|
||
| zero watts | `pv: 0.0` | `goodwe_ctl/pv` = `0.0` | `PV 0 W` |
|
||
|
||
A failed read also **clears** the last good value (`_read_pv()` assigns on every
|
||
call), so a reading never outlives its own sensor. `test_pv.py` part 2 drives a
|
||
good read followed by a dead one, because a fixture that answers the same thing
|
||
forever cannot reach that failure — MUTATION.md habit 9's shape.
|
||
|
||
## 4. It must not become a control input, and that is graded twice
|
||
|
||
### In the suite
|
||
|
||
`test_pv.py` part 6 drives twelve cycles of the real `Controller.cycle()`
|
||
against a 6 kW export and asserts the commands written to the inverter are
|
||
**bit-identical** across `unset` / `no reading` / `0 W` / `8 kW` of production,
|
||
with a precondition check that the stimulus commands something at all (habit 1).
|
||
`inputs_ok` is asserted not to move either: a broken PV integration is **not** a
|
||
missing input, because nothing computes with it.
|
||
|
||
A computed census (habit 12 — the scope is derived from the tree, not typed)
|
||
then reports which of the 33 modules under `app/` mention the material in any
|
||
spelling, comments included. It is **three**: `pv.py`, `main.py`, `mqtt.py`. The
|
||
scanner's own red direction is exercised on every run.
|
||
|
||
### Across trees, by hash
|
||
|
||
`tools/safety56_behaviour_trace.py` is the pattern; `tools/tel11_pv_trace.py` is
|
||
this card's version of it, and **its control clause had to be different**, which
|
||
is worth stating because the difference is the interesting part.
|
||
|
||
SAFETY-56 changed wording and had to show behaviour did not move, so its
|
||
`--compare` **refuses** unless the `sentences` halves **differ** — otherwise the
|
||
two runs might be one tree twice. TEL-11's headline claim is the opposite shape:
|
||
with the option unset, **nothing** differs. "The documents are identical" is the
|
||
*result*, so it cannot also be the control. The two things proved instead are:
|
||
|
||
* the two runs came from **different trees** (`app/*.py` sha256 + byte count,
|
||
compared, and an identity is **refused**);
|
||
* **exactly one** side reacts to `pv_entity` — that side is the HEAD, the other
|
||
is a tree that does not have the option. Neither, or both, is refused.
|
||
|
||
It drives 41 stimulus cells (5 grid worlds × 8 PV schedules, plus a run stopped
|
||
part-way) and prints two documents per setting: `control` — every command
|
||
written, every `self.target`, `inputs_ok`, the loop's three fields, the
|
||
arbiter's resolution, the maintenance phase, tick by tick, **with no TEL-11
|
||
material in it** — and `telemetry`, which is everything the card is allowed to
|
||
move.
|
||
|
||
Measured, in the CI image, on purged trees:
|
||
|
||
```
|
||
HEAD is B; baseline is A (it does not react to `pv_entity`).
|
||
tree A 73296909170ec789237d6e704cce9ab0d9f83b3df1495a14d2497285c3041a12
|
||
tree B d5011b6a18e2e3803dc09cac0214b0378fa4c7388fc0ad8ad89b832a5c92af48
|
||
control A unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
|
||
control B unset 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
|
||
control B set 846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
|
||
telemetry A unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
|
||
telemetry B unset a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
|
||
telemetry B set 4e6d1cb289a957223ad0205f732a6fec6110ce1f2032c98ad60694e67625274f
|
||
OK 1/3 UNSET: control AND telemetry are byte-identical to the baseline tree.
|
||
OK 2/3 SET: the control document is byte-identical with the channel switched on.
|
||
OK 3/3 CONTROL OF THE CONTROL: the telemetry document DOES move when the
|
||
option is set (42 stimulus cells differ).
|
||
```
|
||
|
||
Note what clause 1 claims and clause 2 does not: **unset** is identical in
|
||
`control` *and* `telemetry`, which is stronger than "the control path is
|
||
untouched" — an install that does not set the option sees no change of any kind,
|
||
including its announcement and its status rows. **Set** is identical in
|
||
`control` only, which is the whole of "instrumentation, not an input".
|
||
|
||
## 5. Genuinely optional — and not a second `price_now_entity`
|
||
|
||
`price_now_entity` / `price_avg_entity` are legal **only** while
|
||
`price_provider` is `off`, and the add-on **refuses to start** otherwise. That
|
||
is the trap this card was told not to rebuild, and it is avoided structurally
|
||
rather than by intention:
|
||
|
||
* `validate.py` does not mention `pv_entity` at all. It cannot conflict with
|
||
anything, because nothing else reads it.
|
||
* the MQTT row lives in `OPTIONAL_SENSORS`, not `SENSORS`, and
|
||
`discovery_payloads()`'s new `include` argument **defaults to empty**. So a
|
||
caller that has never heard of `pv_entity` — every fixture in `test_mqtt.py`,
|
||
`tools/rehearse_roster.py`, anything written next year — announces exactly
|
||
what it announced before. `p1_age` solves the same problem the other way
|
||
round, with `omit`, because it is announced by default and withdrawn when the
|
||
meter is off; getting that direction wrong here would have left most installs
|
||
with an entity nothing feeds, which is the hazard `omit`'s own note names.
|
||
* the read is gated on the option, so an unset install makes **no state call at
|
||
all** — not a read that fails quietly.
|
||
* there is **no status row** when it is unset. `peak_forecast_entity` nags when
|
||
it is unset because an unset forecast leaves a money guard without an input;
|
||
this is instrumentation, and a permanent caution on every install that never
|
||
asked for a PV channel is the warning spam the card forbids.
|
||
* when it **is** set and the read fails, the row is `ok=False, warn=True` — a
|
||
**caution**. `status_payload()` builds `NOT READY` out of rows that are
|
||
neither `ok` nor `warn`, so a telemetry channel can never put a battery site
|
||
into `NOT READY`.
|
||
|
||
## 6. The unit is read off the entity, and an unreadable one is refused
|
||
|
||
`read_inputs()` guesses kW-or-W for `peak_forecast_entity` with
|
||
`abs(raw) < 50`, and that is safe there: nobody's quarter-hour demand forecast
|
||
is 50 W. It is **not** safe here — 30 W of real production at dusk is an
|
||
ordinary reading, and that heuristic would publish it as 30 kW.
|
||
|
||
So `pv.watts()` reads the entity's own `unit_of_measurement` and converts
|
||
against Home Assistant's own `UnitOfPower` table (`mW`, `W`, `kW`, `MW`, `GW`,
|
||
`TW`; every factor an exact power of ten). A sensor with **no** unit, or a unit
|
||
outside that table, is **refused by name** and the status page says which. The
|
||
refusal is loud; a guess would be silent, and a factor of 1000 in the one
|
||
channel that exists to be believed a week later is the worse failure.
|
||
|
||
⚠️ `BTU/h` is in HA's enum and is deliberately **not** in the table: its factor
|
||
is a measured conversion rather than a decimal shift, no PV integration
|
||
publishes in it, and a fabricated constant is what this repository's whole
|
||
process exists to prevent. It lands in the refusal, by name, and `test_pv.py`
|
||
part 1 pins that.
|
||
|
||
## 7. The mutation battery
|
||
|
||
Every check this card adds was driven by the mutation that defeats the claim it
|
||
names. Method: `cp -a` of the tree per mutation into a **unique** directory,
|
||
the edit applied there, `__pycache__` purged, the suites run in the CI image
|
||
with the tree bind-mounted `:ro`, one file at a time. **The shipped tree is
|
||
never edited**, so habit 18's revert hazard — SAFETY-37's harness killed between
|
||
the edit and the `cp` that put the file back, and two harnesses sharing one
|
||
backup path — is closed by construction rather than by a verified revert. Each
|
||
row below records the byte delta, the file's sha256 before and after, and that
|
||
the mutated line was **read back off disk** before the run started.
|
||
|
||
| # | mutation | file | bytes | sha256 (first 16) before → after | red on |
|
||
|---|---|---|---|---|---|
|
||
| M1 | the `pv` row moved into `SENSORS`, i.e. announced on every install | `mqtt.py` | −79 B | `328d249b9d698ef6` → `532d3954c023bf3d` | 3 named in `test_mqtt.py`, 1 in `test_pv.py` |
|
||
| M2 | `publish()` drops a `None` `pv` row again, so HA keeps the last number | `mqtt.py` | −98 B | `328d249b9d698ef6` → `dd54be458f446475` | 1 named (the acceptance criterion itself) |
|
||
| M3 | `ABSENT_AS_UNKNOWN` widened past the one key it was written for | `mqtt.py` | +23 B | `328d249b9d698ef6` → `8fe571ebff3dacf4` | 1 named (`circulation` must still be dropped) |
|
||
| M4 | a dead sensor reported as **0 W** instead of an absence | `pv.py` | −1 B | `55ba7471e9995436` → `9eecc34152b7ac12` | 4 named |
|
||
| M5 | `_read_pv()` assigns only on a good read — a value outlives its sensor | `main.py` | +46 B | `c4d2cab34e50b5fd` → `189802aa69ce166d` | 2 named |
|
||
| M6 | the unit is read and then ignored — a kW sensor published as watts | `pv.py` | −18 B | `55ba7471e9995436` → `ab19ef66c52f9379` | 2 named |
|
||
| **M7** | **`self.grid = self.grid − self.pv_w` in `read_inputs()` — PV wired into the control path** | `main.py` | +106 B | `c4d2cab34e50b5fd` → `c38216edb7c5c8db` | **2 named, plus `tel11_pv_trace.py` clause 2/3 on 26 of the 41 stimulus cells** |
|
||
| M8 | `optional_keys()` returns `("pv",)` unconditionally | `mqtt.py` | −52 B | `328d249b9d698ef6` → `86ff23efe3088ad8` | 3 named |
|
||
| M9 | the PV caution made a `bad` row, i.e. a dead sensor is a `NOT READY` | `main.py` | +1 B | `c4d2cab34e50b5fd` → `45c74cab89943564` | 1 named |
|
||
| M10 | the read gate removed — an unset option is read once a second forever | `main.py` | −10 B | `c4d2cab34e50b5fd` → `b67baa8aba3019e8` | 2 named, **plus two crashes** |
|
||
|
||
`on_disk = True` for all ten: the mutated line was grepped back out of the file
|
||
after the edit and before the run (MUTATION.md reporting rule 2), and no
|
||
mutation is size-preserving, so rule 1's `+0 B` caveat does not arise.
|
||
|
||
⚠️ **M10's two extra reds are CRASHES, not named checks, and that is recorded
|
||
rather than tidied away.** Every `Hass` double in `test_inverter.py` and
|
||
`test_telemetry.py` predates this read and has no `state()` method, so an
|
||
unconditional PV read is an `AttributeError` rather than a failed assertion —
|
||
habit 20's shape, a red with no name attached. Fixing those fixtures would be a
|
||
change to what *their* checks report and belongs to whoever next touches them;
|
||
this card's own fixture has `state()` and grades the property by name.
|
||
|
||
⚠️ **M7's trace limb is where the two halves meet.** The mutant moves the
|
||
control document on 26 of 41 cells — every cell whose PV schedule produces a
|
||
READING. The five `none` cells and the five `zero` cells do **not** move, which
|
||
is correct and is worth seeing: subtracting nothing, and subtracting zero,
|
||
change nothing. A battery that only drove a dead sensor would have reported this
|
||
mutation as a survivor for the third time.
|
||
|
||
The clean tree those `before` hashes belong to: `app/main.py`
|
||
`c4d2cab34e50b5fd`, `app/mqtt.py` `328d249b9d698ef6`, `app/pv.py`
|
||
`55ba7471e9995436`.
|
||
|
||
### ⚠️ M7 was a SURVIVOR on the first battery, and the fixture was the reason
|
||
|
||
The card's **central** mutation — `self.grid = self.grid - self.pv_w` in
|
||
`read_inputs()`, i.e. exactly the defect the whole card forbids — came back
|
||
**green** on a six-file run at **+106 B**, on disk, purged, genuinely running.
|
||
|
||
The property did not hold; the fixture could not reach it. `test_pv.py` part 6
|
||
drove a **6 kW export over 12 cycles**, which puts the loop **against its
|
||
rail**: the command moves `slew_w` every cycle and −6000 W and −14 000 W of
|
||
apparent error produce the **same ramp, tick for tick**. MUTATION.md habit 23,
|
||
with a saturated actuator in place of a coinciding value — and the habit's list
|
||
of no-op-prone constructs is all *expressions*, so this is worth its own entry,
|
||
which it now has.
|
||
|
||
The fixture now drives a **600 W import the loop settles on**, with a
|
||
responsive meter (`grid = base − batt`) so the error actually closes, asserts
|
||
the resting target is well inside the rail, and asks habit 23's own question as
|
||
its own check: **shift the meter by the same 8 kW and confirm the commands
|
||
really would have moved.** On the first fixture that question answers *no*, in
|
||
one line. Every number in the table above is from the battery re-run against
|
||
the fixed tree.
|
||
|
||
⚠️ **A red count is a property of the suite as much as of the mutation.** These
|
||
name **this** tree at this commit; a later card that adds or re-bases a check
|
||
moves the number with the mutation untouched. Re-measure rather than inherit.
|
||
|
||
## 8. What none of this covers, with shapes
|
||
|
||
* **Home Assistant itself.** That `None` renders as `unknown` and that the
|
||
recorder keeps a gap is read out of HA's source and quoted in §3; no HA runs
|
||
in this suite. What is graded here is the bytes this add-on publishes.
|
||
* **Whether the operator's sensor tells the truth.** A sensor wired backwards,
|
||
or reporting DC where AC was meant, or a string instead of the array, is
|
||
published faithfully. §2 is the argument for why that is the right failure
|
||
mode; it is not a claim that it cannot happen.
|
||
* **A roster of more than one.** The row is a **site** row — there is one PV
|
||
array as far as this add-on is concerned — so nothing per-unit exists to
|
||
separate, and every fixture is the shipped roster of one.
|
||
* **The attribution.** This card records production. Whether the 20.5 kWh was
|
||
cloud, a limit or the optimiser is OPT-10's, and it needs a week of this
|
||
channel's history before it can be asked.
|
||
* **`tools/`, the firmware and the ingress HTML** are outside part 6's census.
|
||
* **The identity is only as wide as the stimulus.** `tel11_pv_trace.py` prints
|
||
its 41 cells with the documents for exactly that reason.
|
||
|
||
## 9. No `CHANGELOG.md` entry
|
||
|
||
`test_version_gate.py` 11b refuses a newest `## ` heading that is not
|
||
`config.yaml`'s `version:`, and opening an `## Unreleased` section would mean
|
||
taking a packaging decision this card does not get to take. The operator account
|
||
is in `DOCS.md`; the release note belongs to the next PKG ticket, which should
|
||
say that **0.10.1 → next** adds one optional key, announces no new entity on an
|
||
install that does not set it, and changes no control behaviour.
|