Files
goodwe-addon/goodwe_controller/app/main.py
T
glenn schrooyenandClaude Opus 5 aae74d7571 SAFETY-12 review: name the safety claim that could not fire, and fix two figures
Review fixes.

A. test_loop.py takes 73 s, not the ~35 s claimed in three places. That number
is the whole defence against a future developer deleting a slow test, so it was
understated by 2x in exactly the place it matters. Corrected - and it is now
~95 s (measured 93 s), because this commit adds the scenario below rather than
trimming windows to make an inconvenient number smaller. Both call sites carry
an instruction to re-measure if the windows change.

B. "242 checks" was test_p1's own count quoted as the total for all five
suites. The real figure is 395 across the five, plus 14 here.

And the finding this PR should have led with. stale_input_s and the
`inputs missing -> 0 W` claim both live INSIDE cycle(), so pre-fix, on a meter
whose value happened to repeat, that claim could not fire at all. Constant
meter, SoC entity dying at t=4 s, one binary:

  pre-fix   final target 220.0 W, reason 'loop -> 220 W'
  post-fix  final target   0.0 W, reason 'safety -> 0 W'

The old controller held 220 W through the whole input outage with its status
line still reading loop -> 220 W, and layer 1 does not cover that on a
`meter_source: off` install - no P1 age sensor is published, so the firmware has
nothing to veto on, while the heartbeat keeps its watchdog fed. The pre-fix
behaviour was not "holds a stale command safely"; it was a failsafe a repeating
meter switched off. Asserted in test_loop.py, both halves.

Three points of reasoning tightened, none of them wrong before:

- the re-tune is unreachable by construction, not merely by the reset: the
  combined cycle rate is max(arrival rate, 1/floor), never the sum, and 1/15 s
  is strictly slower than the ~1/5 s arrival rate. That holds only while the
  floor exceeds the meter's update interval - and the schema minimum of 5 s is
  exactly the reference meter's interval. Flagged for validate.py, not fixed
  here.
- the ~11 s lower bracket is not only a dropped poll: a 5.0 s poller against a
  4.97 s meter beats, so about every 14 minutes the poller steps over an update
  entirely. Reaching 15 s takes a beat-skip AND a failed poll.
- the "freshness is decided upstream" guarantee is transport-conditional. On
  `meter_source: off` the grid figure comes straight from hass.number() with no
  age gate. Running the full law is still right; the claim is narrower than it
  was stated.

The 15 s default is not independently justified - it rests on the firmware's
30 s ingest veto and moves if that ever does. Said beside the constant.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 21:14:58 +02:00

720 lines
35 KiB
Python

"""GoodWe RS485 Controller add-on - entry point and orchestration.
WHAT THIS THING DOES, in one paragraph: it reads the house's net grid power from
Home Assistant, decides how hard the battery should charge or discharge to hold
that at zero, and writes that figure to an ESP32 which puts it on the inverter's
RS485 meter bus. Once a month it runs a full low->full battery cycle so the BMS
can balance cells and recalibrate its coulomb counter.
⚠️ THE ONE THING TO UNDERSTAND BEFORE CHANGING ANY OF THIS: the inverter holds
the last command it understood FOREVER. It has no meter-timeout of its own.
Measured on real hardware: a controller died mid-command and the inverter held
5 kW of discharge for 113 s until a human noticed. Every failsafe in this system
exists because of that one fact:
layer 1 the ESP32's own watchdog - if we stop refreshing for ~30 s it
commands 0 W and KEEPS WRITING it. Stopping is the failure, not the
fix. This add-on's heartbeat is what feeds it.
layer 2 wind-down before a firmware update, in the ESP32.
layer 3 the optional RS485 e-stop, which writes 0 W after 30 s of total bus
silence. It is the ONLY thing that covers this add-on's host dying.
So: when in doubt, this process stops writing, and the hardware takes the
battery to zero on its own. Never "hold the last value to be safe".
"""
import asyncio
import contextlib
import json
import logging
import signal
from datetime import datetime, timezone
import aiohttp
from .arbiter import (
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_SAFETY, Claim, resolve,
)
from .control import Tuning, compute, maintenance_charge_floor, peak_at_risk
from .hass import HomeAssistant
from .maintenance import IDLE, MaintConfig, Maintenance
from .mqtt import MqttPublisher
from .p1 import P1Ingest, build_source, is_enabled
from .validate import ConfigRefused, refuse, validate_startup_config
from . import web
OPTIONS_PATH = "/data/options.json"
_LOG = logging.getLogger("goodwe")
def load_options() -> dict:
try:
with open(OPTIONS_PATH, "r", encoding="utf-8") as fh:
return json.load(fh)
except (OSError, json.JSONDecodeError) as err:
_LOG.error("cannot read %s (%s) - using defaults", OPTIONS_PATH, err)
return {}
class Controller:
def __init__(self, opts: dict, hass: HomeAssistant, store, mqtt_pub, *, stop):
self.o = opts
self.hass = hass
self.store = store
self.mqtt = mqtt_pub
# ⚠️ REQUIRED, AND KEYWORD-ONLY, AFTER A REVIEW CATCH. This started life
# as `stop=None`, which made a Controller that CANNOT STOP ITSELF the
# default one. On the late-refusal path in run_control() that default
# meant: log the banner, return, and leave the process alive forever
# with no control loop, no exit and no further output - the exact
# "inert but looks healthy" failure this whole module exists to refuse.
# amain() always passed a real Event, so it was latent, but test_p1.py
# was already constructing Controllers without one. No default now, so
# the broken shape does not typecheck.
self.stop_event = stop
self.refused: list[str] | None = None
self.tuning = Tuning(
gain=float(opts.get("gain", 0.6)),
max_w=float(opts.get("max_w", 2000)),
slew_w=float(opts.get("slew_w", 1000)),
deadband_w=float(opts.get("deadband_w", 15)),
target_grid_w=float(opts.get("target_grid_w", 0)),
step_w=int(opts.get("step_w", 10)),
saturation_w=float(opts.get("saturation_w", 500)),
saturation_cycles=int(opts.get("saturation_cycles", 3)),
# 0 / unset means "follow max_w", which is the recommended
# value. Read the note in control.py before raising it above
# max_w: every watt above the rail is unwind latency.
integrator_max_w=(float(opts["integrator_max_w"])
if opts.get("integrator_max_w") else None),
)
self.maint = Maintenance(
MaintConfig(
enabled=bool(opts.get("maintenance_enabled", False)),
interval_days=int(opts.get("maintenance_interval_days", 28)),
start_hour=int(opts.get("maintenance_start_hour", 10)),
discharge_w=float(opts.get("maintenance_discharge_w", 2500)),
charge_w=float(opts.get("maintenance_charge_w", 2500)),
soc_floor=float(opts.get("maintenance_soc_floor", 11)),
soc_target=float(opts.get("maintenance_soc_target", 99)),
hold_min=int(opts.get("maintenance_hold_min", 120)),
),
store,
)
# P1 ingestion (TEL-01). `meter_source: off` keeps the original
# single-entity meter_entity path, so an existing install is unchanged
# until it opts in.
self.p1 = P1Ingest(phases=int(opts.get("meter_phases", 1)),
max_age_s=float(opts.get("meter_max_age_s", 30)))
self.p1_enabled = is_enabled(opts)
# Set by amain() once the transport is built, so the status page can show
# what only the transport knows (homewizard_local's unchanged_s). Stays
# None when P1 is off, or under a transport that has no such counter.
self.p1_source = None
# live state
self.auto = bool(store.data.get("auto", opts.get("auto_start", False)))
self.target = 0.0
self.sat_count = 0
self.i_w = 0.0 # the loop's integrator, carried between cycles
self.loop_w = None # what the loop asked for last cycle, or None
self.reason = "starting"
self.grid = self.soc = self.batt = None
self.peak_fc = None
self.cheap = False
self.last_write = None
self.last_write_at = None
self.last_write_ok = None
self.inputs_bad_since = None
self.dev_min = self.dev_max = None
self.events: list[str] = []
self.stopping = False
# -- helpers -------------------------------------------------------------
def log_event(self, msg: str) -> None:
stamp = datetime.now(timezone.utc).strftime("%H:%M:%S")
self.events.insert(0, f"{stamp} {msg}")
del self.events[40:]
@property
def inputs_ok(self) -> bool:
return None not in (self.grid, self.soc, self.batt)
# -- io ------------------------------------------------------------------
async def read_inputs(self) -> None:
o = self.o
if self.p1_enabled:
# ⚠️ P1 is the only authoritative measurement of what the utility
# sees (§5.1). When it is stale this is None, which falls into the
# existing "inputs missing -> command 0 W" path below. There is
# deliberately NO fallback to an inverter-side figure: the
# inverter's own AC power correlates 0.998 with battery power and
# 0.09 with the real meter, so a controller that failed over to it
# would be regulating against its own output.
self.grid = self.p1.net_w
else:
self.grid = await self.hass.number(o.get("meter_entity", ""),
bool(o.get("meter_invert")))
self.soc = await self.hass.number(o.get("soc_entity", ""))
self.batt = await self.hass.number(o.get("batt_entity", ""),
bool(o.get("batt_invert")))
if o.get("peak_forecast_entity"):
raw = await self.hass.number(o["peak_forecast_entity"])
# Accept kW or W - nobody's quarter-hour forecast is 50 W.
self.peak_fc = None if raw is None else (raw * 1000 if abs(raw) < 50 else raw)
else:
self.peak_fc = None
now_e, avg_e = o.get("price_now_entity"), o.get("price_avg_entity")
if now_e and avg_e:
now_p = await self.hass.number(now_e)
avg_p = await self.hass.number(avg_e)
self.cheap = (now_p is not None and avg_p is not None and now_p <= avg_p)
else:
# Fixed-tariff site: never force a paid grid top-up, wait for sun.
self.cheap = False
if self.inputs_ok:
if self.inputs_bad_since is not None:
self.log_event("inputs recovered")
self.inputs_bad_since = None
elif self.inputs_bad_since is None:
self.inputs_bad_since = datetime.now(timezone.utc)
async def write_setpoint(self, value: float, *, force: bool = False) -> None:
entity = self.o.get("setpoint_entity", "")
if not entity:
return
# Never send a value the device will reject outright. A rejected write is
# silent from the controller's point of view, and the inverter then keeps
# doing whatever it was already doing.
if self.dev_min is not None and self.dev_max is not None:
value = max(self.dev_min, min(self.dev_max, value))
changed = (self.last_write is None or value != self.last_write)
if not (changed or force):
return
ok = await self.hass.set_number(entity, value)
self.last_write_ok = ok
if ok:
self.last_write = value
self.last_write_at = datetime.now(timezone.utc)
# -- the cycle -----------------------------------------------------------
async def cycle(self) -> None:
"""Gather claims, resolve precedence, write the winner.
Nothing here decides who wins - arbiter.py does, by one rule. This
method's only job is to state honestly what each strategy wants.
"""
now = datetime.now(timezone.utc)
result = self.maint.tick(now, self.soc)
for msg in result.events:
self.log_event(msg)
stale_after = float(self.o.get("stale_input_s", 15))
if not self.inputs_ok:
bad_for = (now - self.inputs_bad_since).total_seconds() if self.inputs_bad_since else 0.0
if bad_for < stale_after:
# A single missed poll is not a fault. Hold, keep the heartbeat
# going, and give it a few seconds to come back.
self.reason = f"inputs missing {bad_for:.0f}s"
return
claims = []
# --- safety limits: these bind EVERY strategy, always ----------------
# Defence in depth: write_setpoint() clamps to the device range too. The
# duplication is deliberate - one of them is the policy, the other is the
# last thing between a bug and the hardware.
if self.dev_min is not None and self.dev_max is not None:
claims.append(Claim.limit("device", P_SAFETY, self.dev_min, self.dev_max, "rating"))
max_w = float(self.o.get("max_w", 2000))
claims.append(Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"))
# --- safety stops ----------------------------------------------------
if not self.auto:
claims.append(Claim.set("safety", P_SAFETY, 0.0, "stopped"))
elif not self.inputs_ok:
if self.target != 0.0:
self.log_event("inputs missing - commanding 0 W")
claims.append(Claim.set("safety", P_SAFETY, 0.0, "inputs missing"))
# --- maintenance -----------------------------------------------------
if result.owns_setpoint:
claims.append(Claim.set("maintenance", P_MAINTENANCE,
float(result.setpoint_w or 0.0), result.phase))
self.sat_count = 0
elif result.charge_only:
# Money outranks the maintenance schedule: while the quarter-hour
# projection is over the cap, the charge-only shaping is simply not
# claimed, so the loop can discharge and shave the peak. When a
# dedicated peak-shaving strategy arrives it will claim SET at
# P_PEAK and outrank this limit without any code here changing.
if peak_at_risk(self.peak_fc, float(self.o.get("peak_cap_w", 3500))):
self.log_event("peak at risk - maintenance charge shaping suspended")
else:
hi = 0.0
reason = "charge-only"
if self.cheap:
floor = maintenance_charge_floor(
float(self.o.get("maintenance_charge_w", 2500)),
self.peak_fc, float(self.o.get("peak_cap_w", 3500)))
if floor > 0:
hi, reason = -floor, "cheap-window charge"
claims.append(Claim.limit("maintenance", P_MAINT_SHAPE, hi=hi, reason=reason))
# --- the grid-following loop -----------------------------------------
if self.auto and self.inputs_ok:
# ⚠️ prev is the ARBITER's last output, not the loop's own last
# wish. If something outranked the loop, that is what the hardware
# actually did, and the controller must track reality or it jumps
# the moment it regains control.
#
# ⚠️ The integrator has to track the same reality, and it is no
# longer prev_w, so it needs saying out loud: if the arbiter did not
# give the loop what it asked for last cycle, the loop's
# accumulated error belongs to a command that never happened.
# Re-seed from what the hardware was actually told. This is the
# failsafe case too - every layer-1 stop resolves to 0 W, so
# entering failsafe re-seeds the integrator to zero and the first
# cycle after release starts from zero instead of dumping the whole
# stale period as power.
if self.loop_w is None or self.target != self.loop_w:
self.i_w = self.target
decision = compute(
prev_w=self.target,
grid_w=self.grid,
actual_w=self.batt,
tuning=self.tuning,
sat_count=self.sat_count,
i_w=self.i_w,
)
if decision.frozen and self.sat_count < self.tuning.saturation_cycles:
self.log_event(f"saturation freeze ({self.target:.0f} W vs {self.batt:.0f} W)")
self.sat_count = decision.sat_count
self.i_w = decision.i_w
self.loop_w = decision.target_w
claims.append(Claim.set("loop", P_LOOP, decision.target_w, decision.reason))
else:
# Stopped or blind: no accumulation may survive the outage.
self.i_w = 0.0
self.loop_w = None
resolution = resolve(claims)
if resolution.contradiction:
self.log_event("ARBITER CONTRADICTION - commanding 0 W, see the log")
self.target = resolution.target_w
self.reason = resolution.explain()
await self.write_setpoint(self.target)
# -- tasks ---------------------------------------------------------------
async def run_control(self) -> None:
entity = self.o.get("setpoint_entity", "")
if entity:
self.dev_min, self.dev_max, _ = await self.hass.limits(entity)
# ⚠️ THIS USED TO WARN AND CARRY ON, and that was the bug CFG-01
# exists to remove: a max_w above the device's rating meant
# write_setpoint() silently clamped and the configured ceiling was
# never the real one.
#
# amain() already ran this gate before anything started. It runs
# AGAIN here for one case the gate cannot cover: ESPHome is often
# not up yet when the add-on boots, so hass.limits() returned
# (None, None) and the range checks were skipped rather than
# guessed at. This is the first moment the device's real rating is
# known. If it conflicts, refuse now - stopping deterministically
# through the normal shutdown, which commands 0 W on the way out.
problems = validate_startup_config(self.o, self.dev_min, self.dev_max)
if problems:
refuse(problems)
self.refused = problems
self.log_event("REFUSED: " + problems[0])
# Signal, then return WITHOUT entering the loop. amain() wakes
# on this, runs the normal wind-down (which commands 0 W) and
# re-raises ConfigRefused afterwards, so the exit code is 78 and
# the inverter is left at zero rather than latched.
self.stop_event.set()
return
last_grid = object()
heartbeat = float(self.o.get("heartbeat_s", 10))
last_beat = 0.0
# ⚠️ SAFETY-12. The floor is a DEADLINE ON THE GAP BETWEEN CYCLES, not a
# second scheduler running alongside the arrival trigger. Every cycle
# resets it, whichever trigger fired, so on a healthy changing meter it
# never elapses and not one existing cycle moves - and therefore no
# change to the per-cycle gain the tuning was measured against.
#
# That is true twice over, and the second reason is the sturdier one:
# the combined cycle rate is max(arrival rate, 1/floor), never the sum.
# At the defaults 1/15 s is strictly slower than the ~1/5 s arrival
# rate, so even a floor that raced the arrivals could not push the loop
# past its nominal healthy rate. The re-tune is unreachable by
# construction, not merely by the reset. ⚠️ That argument holds only
# while floor > the meter's update interval - which is why the schema
# minimum of 5 s deserves the second look validate.py has not given it
# yet: 5 s IS the reference meter's interval, i.e. the one configurable
# value that would double the cycle rate.
#
# Why it has to exist, and it is not only about latency: `self.grid !=
# last_grid` alone means a meter that repeats a value runs NO control
# cycles at all. The heartbeat below keeps re-emitting the last command
# and the firmware keeps putting it on the wire, so every indicator
# reads healthy - and, worse, the `inputs missing -> 0 W` claim lives
# INSIDE cycle(), so on a repeating meter THAT SAFETY CLAIM CANNOT FIRE.
# Demonstrated in test_loop.py: constant meter, SoC entity dies at t=4 s,
# and the pre-fix controller holds 220 W through the whole outage with
# the status line still reading "loop -> 220 W". Layer 1 does not cover
# it on a `meter_source: off` install either - no P1 age sensor is
# published, so the firmware has nothing to veto on. Measured on the rig
# during TEL-05: 70 s at a literally constant 350.0 W, 14 arrivals, zero
# cycles.
#
# This is NOT a freeze detector, and deliberately so - see
# HomeWizardLocalSource.unchanged_s for why one cannot be built here (at
# the converged -10 W target a 1 Wh register needs ~6 minutes to move,
# so any freeze threshold false-trips at the exact operating point we
# run at). Nothing here decides whether a repeated reading is true. It
# only stops "the number is the same" from meaning "do not think".
#
# ⚠️ THE 15 s DEFAULT HAS A CEILING IT DOES NOT OWN. It is under
# validate.FIRMWARE_INGEST_VETO_S (30 s) and under meter_max_age_s on
# purpose, so the loop re-decides at least twice inside any window in
# which layer 1 might otherwise be the only thing deciding. If the
# firmware's veto ever moves, this default moves with it - it is not
# independently justified at 15.
floor = float(self.o.get("cycle_floor_s", 15))
last_cycle = None
while not self.stopping:
await self.read_inputs()
now_mono = asyncio.get_running_loop().time()
# A cycle is one meter update, exactly as on the reference install -
# or the floor elapsing, whichever comes first.
overdue = last_cycle is None or (now_mono - last_cycle) >= floor
if self.grid != last_grid or overdue:
last_grid = self.grid
last_cycle = now_mono
# ⚠️ The FULL cycle, not a degraded one. A floor cycle runs the
# same law on the same inputs as an arrival cycle, because in P1
# mode the freshness question is already answered upstream and
# answered harder: past `meter_max_age_s` (30 s) p1.net_w is
# None, which is "inputs missing", which becomes a P_SAFETY 0 W
# claim. So a floor cycle cannot run the PI on a 60 s old
# figure, because at 60 s there is no figure.
#
# ⚠️ THAT GUARANTEE IS TRANSPORT-CONDITIONAL, and saying so
# matters more than the guarantee: with `meter_source: off`,
# read_inputs() takes self.grid straight from hass.number() with
# NO age gate at all, so a Home Assistant entity that has gone
# quiet reads as a current value on that path with or without
# this change. Running the full law is still the right choice
# there - the alternative is a degraded second law reasoning
# about an age nobody measured - but the floor does not make
# that path fresh, and nothing here should be read as claiming
# it does. And the integrator
# advances per CYCLE, not per second (control.py), so bounding
# the gap bounds the accumulation: at most one extra
# gain x error per floor interval, under the same
# integrator_max_w as every other cycle. A second, gentler
# control law for floor cycles would be a second set of
# dynamics nobody can test on this hardware.
await self.cycle()
# ⚠️ The heartbeat is not an optimisation. The ESP32 treats silence
# longer than ~30 s as "the controller is gone" and zeroes the
# inverter. Refreshing the SAME value is what proves we are alive.
loop_now = asyncio.get_running_loop().time()
if loop_now - last_beat >= heartbeat:
last_beat = loop_now
await self.write_setpoint(self.target, force=True)
self.publish()
await asyncio.sleep(1)
def publish(self) -> None:
values = {
"setpoint": self.target,
"grid": self.grid,
"battery": self.batt,
"soc": self.soc,
"phase": self.maint.phase,
"status": "running" if self.auto else "stopped",
}
# ⚠️ ONLY when P1 ingestion is actually running. The ESP32's stale-input
# watchdog subscribes to sensor.goodwe_p1_sample_age - see the entity-id
# note in mqtt.py; the composed name is not the object_id - and forces layer-1
# failsafe once it reaches max_age_s. With meter_source off there is no
# ingester feeding it, so published_age_s would be time-since-startup
# climbing without bound - i.e. every existing install would cross the
# threshold within 30 s and pin its inverter at 0 W forever. Publishing
# nothing leaves the entity non-existent, which is the status quo and
# what has_state() in the firmware is checking for.
if self.p1_enabled:
# Recomputed here, once a second, on purpose - see P1Ingest.
values["p1_age"] = round(self.p1.published_age_s, 1)
self.mqtt.publish(values)
async def shutdown(self) -> None:
"""Deterministic wind-down. Do not skip this."""
self.stopping = True
_LOG.info("shutting down - commanding 0 W")
await self.write_setpoint(0.0, force=True)
self.mqtt.close()
# -- UI ------------------------------------------------------------------
def checks(self) -> list:
o = self.o
out = []
if self.p1_enabled:
age = self.p1.published_age_s
if self.p1.stale:
out.append({"ok": False, "warn": False,
"text": f"P1 meter ({o.get('meter_source')}): no reading for "
f"{age:.0f} s (limit {self.p1.max_age_s:.0f} s)"
+ (f" - last error: {self.p1.last_error}"
if self.p1.last_error else "")})
else:
# ⚠️ unchanged_s is REPORTED, never thresholded and never folded
# into the age - see HomeWizardLocalSource.unchanged_s for why
# (at the converged -10 W this controller aims for, a 1 Wh
# register needs ~6 minutes to move, so any limit false-trips at
# the exact operating point we target). The whole argument for
# leaving it unthresholded is that a human interprets it, which
# requires a human being able to see it - so here it is. getattr:
# only homewizard_local has one, and p1_source is None until
# amain() builds the transport.
unchanged = getattr(self.p1_source, "unchanged_s", None)
out.append({"ok": True, "warn": False,
"text": f"P1 meter ({o.get('meter_source')}): {self.p1.net_w:g} W, "
f"{age:.0f} s old, {self.p1.samples} telegrams, "
f"{self.p1.parse_errors} rejected"
+ (f", measurement unchanged for {unchanged:.0f} s"
if unchanged is not None else "")})
rows = [("battery SoC", self.soc, o.get("soc_entity")),
("battery power", self.batt, o.get("batt_entity"))]
if not self.p1_enabled:
# In P1 mode the check above replaces this one; leaving both in
# would report "no entity configured" for a meter_entity that is
# correctly unused, i.e. a permanent false NOT READY.
rows.insert(0, ("grid power", self.grid, o.get("meter_entity")))
for label, value, entity in rows:
if not entity:
out.append({"ok": False, "warn": False, "text": f"{label}: no entity configured"})
elif value is None:
out.append({"ok": False, "warn": False,
"text": f"{label}: {entity} is missing or not numeric"})
else:
out.append({"ok": True, "warn": False, "text": f"{label}: {entity} = {value:g}"})
sp = o.get("setpoint_entity")
if not sp:
out.append({"ok": False, "warn": False, "text": "setpoint entity not configured"})
elif self.dev_max is None:
out.append({"ok": False, "warn": False,
"text": f"setpoint entity {sp} not found"})
else:
out.append({"ok": True, "warn": False,
"text": f"setpoint {sp} (range {self.dev_min:g}…{self.dev_max:g} W)"})
if self.last_write_ok is False:
out.append({"ok": False, "warn": False,
"text": "last write to the inverter was REJECTED - check the log"})
if not o.get("estop_fitted", False):
out.append({"ok": False, "warn": True,
"text": "no e-stop fitted: if this host dies the battery stays "
"latched at its last command"})
else:
out.append({"ok": True, "warn": False, "text": "e-stop fitted"})
if not o.get("peak_forecast_entity"):
# ok=False + warn=True renders as a caution, not a pass. A check that
# is both is a check nobody reads.
out.append({"ok": False, "warn": True,
"text": "no peak forecast: maintenance charging is not capacity-capped"})
return out
def status_payload(self) -> dict:
checks = self.checks()
bad = [c for c in checks if not c["ok"] and not c["warn"]]
if bad:
level, banner = "bad", f"NOT READY — {bad[0]['text']}"
elif not self.auto:
level, banner = "warn", "Stopped — inverter commanded to 0 W"
elif self.maint.phase != IDLE:
level, banner = "warn", f"Maintenance: {self.maint.phase}"
else:
level, banner = "ok", "Running — holding grid at zero"
def w(v):
return "—" if v is None else f"{v:,.0f} W".replace(",", " ")
next_due = self.maint.next_due(datetime.now(timezone.utc))
rows = [
("Grid", w(self.grid)),
("Battery", w(self.batt)),
("State of charge", "—" if self.soc is None else f"{self.soc:g} %"),
("Commanded", w(self.target)),
("Why", self.reason),
("Maintenance phase", self.maint.phase),
("Maintenance due", "now" if next_due is None else next_due.strftime("%Y-%m-%d")),
("Cheap window", "yes" if self.cheap else "no"),
]
return {
"banner": banner, "level": level, "rows": rows, "checks": checks,
"hint": self.events[0] if self.events else "",
}
async def handle_action(self, what: str):
now = datetime.now(timezone.utc)
if what == "auto_toggle":
self.auto = not self.auto
self.store.set("auto", self.auto)
self.log_event("control started" if self.auto else "control stopped")
if not self.auto:
self.target = 0.0
await self.write_setpoint(0.0, force=True)
return {"auto": self.auto}
if what == "maint_start":
for msg in self.maint.force_start(now):
self.log_event(msg)
return {"phase": self.maint.phase}
if what == "maint_abort":
for msg in self.maint.abort(now, "operator"):
self.log_event(msg)
self.target = 0.0
await self.write_setpoint(0.0, force=True)
return {"phase": self.maint.phase}
return None
async def amain() -> None:
opts = load_options()
logging.basicConfig(
level=getattr(logging, str(opts.get("log_level", "info")).upper(), logging.INFO),
format="%(asctime)s %(levelname)-7s %(name)s: %(message)s",
)
_LOG.info("GoodWe RS485 Controller starting")
from .store import Store
store = Store()
async with aiohttp.ClientSession() as session:
hass = HomeAssistant(session)
# Startup self-check: prove we can actually reach the Core API before
# anything tries to control an inverter with it. A 401 here is a
# permissions/token problem, not a configuration mistake, and saying so
# explicitly saves an installer from re-checking entity ids for an hour.
import os as _os
_tok = _os.environ.get("SUPERVISOR_TOKEN", "")
_LOG.info("supervisor token: %s (%d chars); env has: %s",
"present" if _tok else "MISSING", len(_tok),
",".join(sorted(k for k in _os.environ if "TOKEN" in k.upper())) or "none")
try:
async with session.get("http://supervisor/core/api/",
headers={"Authorization": f"Bearer {_tok}"},
timeout=10) as _r:
_LOG.info("core api probe: HTTP %s %s", _r.status, (await _r.text())[:80])
except Exception as _e: # noqa: BLE001
_LOG.error("core api probe failed: %s", _e)
# ⚠️ THE STARTUP GATE (CFG-01). Nothing below this line may run on a
# configuration validate.py rejects - specs §1.5: a config the system
# cannot honour is refused at startup, not survived at runtime.
#
# It sits HERE, before the broker, before the web server and before any
# task exists, so a refusal cannot leave half a controller running with
# a UI in front of it. Reading the device range is the one thing the
# validator cannot do for itself; (None, None) when ESPHome has not come
# up yet is not a refusal - run_control() re-checks once the real rating
# is known. See validate.py for where the line is drawn and why.
_sp = str(opts.get("setpoint_entity", "") or "").strip()
_dev_min = _dev_max = None
if _sp:
_dev_min, _dev_max, _ = await hass.limits(_sp)
_LOG.info("setpoint device %s reports range %s…%s W", _sp, _dev_min, _dev_max)
_problems = validate_startup_config(opts, _dev_min, _dev_max)
if _problems:
refuse(_problems)
raise ConfigRefused(_problems)
# ⚠️ Status publishing must NEVER be able to stop the controller. A
# broken broker, a missing library, an API change in paho - all of it is
# observability, and the battery does not care. Caught broadly and on
# purpose: this crashed the add-on once already (paho 1.x vs 2.x) and
# took the control loop down with it.
broker = None
try:
broker = await hass.mqtt_service()
pub = MqttPublisher(
broker.get("host") if broker else None,
broker.get("port", 1883) if broker else 1883,
broker.get("username") if broker else None,
broker.get("password") if broker else None,
omit=() if is_enabled(opts) else ("p1_age",),
)
except Exception as err: # noqa: BLE001
_LOG.warning("MQTT unavailable (%s) - continuing without status entities", err)
class _NoMqtt:
enabled = False
def publish(self, *a, **k): pass
def close(self): pass
pub = _NoMqtt()
stop = asyncio.Event()
controller = Controller(opts, hass, store, pub, stop=stop)
runner = await web.start(controller, port=8099)
loop = asyncio.get_running_loop()
for sig in (signal.SIGTERM, signal.SIGINT):
with contextlib.suppress(NotImplementedError):
loop.add_signal_handler(sig, stop.set)
tasks = [asyncio.create_task(controller.run_control())]
# P1 ingestion runs as its own long-lived task. ⚠️ It must not be driven
# off the control loop: telegrams arrive every ~5 s and the loop would
# decimate them, so the 15-minute average - the capacity-tariff billing
# unit - would be computed from a fraction of the data.
p1_source = build_source(opts, controller.p1, session, broker)
if p1_source is not None:
controller.p1_source = p1_source # so checks() can report on it
tasks.append(asyncio.create_task(p1_source.run()))
await stop.wait()
await controller.shutdown()
for task in tasks:
task.cancel()
for task in tasks:
with contextlib.suppress(asyncio.CancelledError):
await task
await runner.cleanup()
_LOG.info("stopped")
# The late-arriving-device refusal from run_control(). Re-raised only
# now, so the wind-down above still ran and the inverter is at 0 W.
if controller.refused:
raise ConfigRefused(controller.refused)
def main() -> None:
try:
asyncio.run(amain())
except KeyboardInterrupt:
pass
except ConfigRefused:
# ⚠️ No traceback, on purpose. The banner refuse() already printed says
# everything an operator needs, and a stack trace on top of it would say
# "this crashed" - the exact confusion AC3 is about. 78 is sysexits(3)
# EX_CONFIG, so even a script reading the exit status can tell a bad
# config from a bug.
raise SystemExit(78)
if __name__ == "__main__":
main()