Also documents the two things that stop an install dead: the repository must be public for Home Assistant to clone it anonymously (a private repo shows nothing in the store and gives no useful error), and config.yaml's `version` must be bumped for every change or Supervisor reuses the previously built image. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
107 lines
4.4 KiB
Markdown
107 lines
4.4 KiB
Markdown
# GoodWe RS485 Controller — Home Assistant add-on repository
|
|
|
|
Replaces a GoodWe battery inverter's vendor controller with a local one: holds
|
|
net grid exchange at zero by emulating the inverter's smart meter over RS485,
|
|
and runs the monthly battery maintenance cycle the vendor box was doing.
|
|
|
|
```
|
|
repository.yaml add-on repository metadata
|
|
goodwe_controller/ the add-on
|
|
config.yaml manifest + options schema (the per-site config form)
|
|
app/ the controller
|
|
control.py the control law — pure functions, no I/O
|
|
maintenance.py the monthly cycle state machine
|
|
hass.py Supervisor/Core API access
|
|
store.py persistent state in /data
|
|
mqtt.py optional status entities
|
|
web.py ingress UI
|
|
main.py orchestration, heartbeat, failsafe behaviour
|
|
test_control.py runnable checks — no framework needed
|
|
test_maintenance.py runnable checks — walks a full cycle in fake time
|
|
DOCS.md the add-on's documentation tab
|
|
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
|
|
estop/rs485_log.py optional RS485 e-stop / bus witness
|
|
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4)
|
|
docs/build_guide.py its single source - rebuilds the HTML and PDF
|
|
FIELD-GUIDE.md how to edit and rebuild the guide
|
|
```
|
|
|
|
## Install
|
|
|
|
Settings → Add-ons → Add-on store → ⋮ → **Repositories** → add
|
|
|
|
```
|
|
https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon
|
|
```
|
|
|
|
then install **GoodWe RS485 Controller**.
|
|
|
|
⚠️ **The repository must be PUBLIC for this to work.** Home Assistant clones it
|
|
anonymously; against a private repo the store shows nothing and gives no useful
|
|
error. If it must stay private, install locally instead: copy
|
|
`goodwe_controller/` into the machine's `/addons/` folder, then
|
|
`ha store reload` — it appears as a Local add-on.
|
|
|
|
⚠️ **Bump `version:` in `goodwe_controller/config.yaml` for every change.**
|
|
Supervisor keys the built image by that version, so without a bump it silently
|
|
reuses the old image and your fix appears not to work — on your bench and on
|
|
every client's machine.
|
|
|
|
Requires **Home Assistant OS or Supervised**. Add-ons cannot be installed on HA
|
|
Container or Core.
|
|
|
|
## Read this first
|
|
|
|
**The inverter holds its last command forever.** It has no meter-timeout of its
|
|
own — a controller that dies mid-command leaves the battery running until a
|
|
human intervenes. Measured on real hardware: 5 kW of discharge held for 113
|
|
seconds after a controller went silent.
|
|
|
|
Three layers exist because of that, and only the third covers the Home Assistant
|
|
machine itself dying:
|
|
|
|
1. **ESP32 watchdog** — no fresh setpoint for ~30 s → command 0 W, and keep
|
|
commanding it.
|
|
2. **Wind-down before firmware updates** — 0 W written before the update starts.
|
|
3. **RS485 e-stop (optional)** — writes 0 W after 30 s of total bus silence.
|
|
|
|
Sites sold without the e-stop must have the acknowledgement in `FIELD-GUIDE.md`
|
|
§10 signed.
|
|
|
|
## Development
|
|
|
|
The control law and the maintenance machine are pure Python with no Home
|
|
Assistant imports, so they run anywhere:
|
|
|
|
```bash
|
|
cd goodwe_controller
|
|
python3 test_control.py
|
|
python3 test_maintenance.py
|
|
```
|
|
|
|
Both must pass before shipping any change. They are not unit-test theatre —
|
|
each assertion corresponds to a rule whose absence produced an observed failure
|
|
on real hardware, and the comments in `control.py` say which.
|
|
|
|
## Compatibility
|
|
|
|
**Check the serial number, not the model name.** Characters 6-8 of the serial are
|
|
the platform tag:
|
|
|
|
| tag | platform | verdict |
|
|
|---|---|---|
|
|
| `ESU EMU ESA BPS BPU EMJ IJL` | 105 — ES/EM/BP, AA55-era meter bus | **supported** |
|
|
| `SPB SPN` | 745 — SBP **G2** (`GW…-SBP-20`) | no |
|
|
| `ESN ESC` | 745 — ES **G2** (`GW…-ES-20`) | no |
|
|
| `ETU EHU BTU …` | 205/745/753 — ET/EH/BT hybrids | no |
|
|
| `SDT DST MSU NSU …` | PV-only inverters — no battery to control | no |
|
|
|
|
A "-20" or "G2" suffix means a different platform with a different meter
|
|
protocol. The tags come from the `goodwe` library's `PLATFORM_105_MODELS`, which
|
|
is also what Home Assistant's own integration uses to pick a protocol.
|
|
|
|
- GoodWe **ES / BP family** inverters (AA55 / RS485 meter-bus generation)
|
|
- The protocol is **reverse-engineered**. There is no vendor contract, and a
|
|
firmware change on GoodWe's side could break every installation at once. Say
|
|
so when you sell it.
|