OPT-11 P1 review: a mode never beats the peak floor; SAFETY-03 kept at the rail
- arbiter: a mode now gives way only as far as a site limit above P_MODE
  needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
  released only when the peak floor bound S, so a trade won above the floor
  kept them and placed less than the floor (an Off battery at N=1 went to 0 W
  under a 2000 W floor), and a capped grid charge released an Off battery.
  While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
  rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
  (peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
  loop bound counts live units only). DOCS and DECISIONS say the new rule.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 19:41:36 +02:00
..