Files
adminandClaude Opus 5.5 6862dea52a
checks / unit (pull_request) Successful in 39m4s
infra-pin / fresh (pull_request) Successful in 2s
PRICE-01 review 3: tests for the round 3 note and dismiss; doc wording
- test_price_secret.py: the fixed-tariff note on the real /config/validate
  route, EN and NL, and none for a spaces-only profile (web.py lang wiring).
- test_price_service.py: the start line is INFO, not WARNING; a dismiss that
  raises does not stop the cycle.
- test_maint13/test_setup_only/test_watchdog: ignore only the dismiss of the
  old card, so a create with that id is still counted.
- DECISIONS rule 7 quotes the settings note as it is; messages.py comment.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 22:07:09 +02:00

575 lines
24 KiB
Python

"""MAINT-13: a full pack that stops at 98-99 % is not a failed charge.
`python3 test_maint13.py`
Graded here: the stall rule, the near-full timeout rule, the 7 day back-off
after a failed cycle (and what ends it), the timeout counting only the minutes
the price gate was open, restart and old-state-file behaviour, the notification
(once), and the Controller wiring at one and two packs.
See DECISIONS/MAINT-13-full-pack-is-complete.md.
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
"""
import asyncio
import json
import os
import re
import sys
import tempfile
from datetime import datetime, timedelta, timezone
from pathlib import Path
from app import messages
from app.maintenance import (
CHARGE, CHARGE_NEAR_FULL_PCT, CHARGE_STALL_MIN, CHARGE_TIMEOUT_MIN,
CHARGE_WALL_TIMEOUT_MIN, DRAIN, FAIL_BACKOFF_DAYS, HOLD, IDLE,
MaintConfig, Maintenance, arbitrate,
)
from app.main import Controller
from app.store import (DEFAULTS, MAINT_UNIT_KEYS, Store, migrate_maint_keys,
unit_key)
HERE = Path(__file__).resolve().parent
UTC = timezone.utc
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
# The live site: target 100, shipped hold. Start hour 19 UTC for the schedule.
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
discharge_w=2000, charge_w=2000, soc_floor=11,
soc_target=100, hold_min=120)
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC) # B's drain ended (live)
MIN = timedelta(minutes=1)
class Mem:
"""Store's surface, no disk; times kept as the real Store keeps them."""
def __init__(self, data=None):
self.data = dict(DEFAULTS, **(data or {}))
def set(self, k, v):
self.data[k] = v
def set_time(self, k, when):
self.data[k] = when.astimezone(UTC).isoformat() if when else None
def get_time(self, k):
raw = self.data.get(k)
return datetime.fromisoformat(raw) if raw else None
def save(self):
pass
def in_charge(store=None, cfg=CFG, at=T0):
"""A pack that has just finished its drain and is charging at `at`."""
m = Maintenance(cfg, store or Mem())
m.force_start(at)
m.tick(at, 11.0) # drain complete -> charge
assert m.phase == CHARGE
return m
def run(m, start, minutes, soc, gate=True, step=1):
"""Tick every `step` minutes for `minutes`; `soc` is a number or f(minute).
Returns (the last result, the time after the run, the first non-CHARGE result)."""
t, res, out = start, None, None
for i in range(0, minutes, step):
t = start + i * MIN
s = soc(i) if callable(soc) else soc
res = m.tick(t, s, gate_open=gate)
if out is None and res.phase != CHARGE:
out = (res, t)
break
return res, start + minutes * MIN, out
print("1. the stall rule: near full and no longer taking charge")
# Live record: 99 % at 04:00, back to 98 % at 04:15, never 100.
m = in_charge()
res, end, out = run(m, T0 + 60 * MIN, 400, lambda i: 99.0 if i < 15 else 98.0)
check("a pack that reaches 99 and falls back to 98 completes (HOLD) after "
f"{CHARGE_STALL_MIN} min without a new high",
out is not None and out[0].phase == HOLD)
check("...at 60 min after the last new high (the 99), not before",
out is not None and out[1] == T0 + 120 * MIN)
check("...with one plain log line",
out is not None and len(out[0].events) == 1
and "takes no more charge at 98 %" in out[0].events[0])
m = in_charge()
res, _, out = run(m, T0, 59, 98.0)
check("59 minutes flat is not enough", out is None and res.phase == CHARGE)
m = in_charge()
res, _, out = run(m, T0, 61, lambda i: 97.0)
check("target - 3 (97 of 100) counts as near full", out and out[0].phase == HOLD)
m = in_charge()
res, _, out = run(m, T0, 300, lambda i: 96.0)
check("target - 4 (96 of 100) does not complete however long it is flat",
out is None)
cfg99 = MaintConfig(enabled=True, start_hour=19, soc_target=99, hold_min=120)
m = in_charge(cfg=cfg99)
res, _, out = run(m, T0, 61, lambda i: 96.0)
check("the shipped target 99 works the same way (96 is near full)",
out and out[0].phase == HOLD)
m = in_charge()
res, _, out = run(m, T0, 400, lambda i: min(99.0, 94.0 + i // 30))
check("a pack still rising 1 point per 30 min is not stalled: it completes 60 "
"min after the 99 at minute 150", out and out[1] == T0 + 210 * MIN)
m = in_charge()
res, _, out = run(m, T0, 130, lambda i: 97.0 if i < 50 else (98.0 if i < 100 else 98.0))
check("a new high resets the wait: 97 flat for 50 min, 98 at 50 min -> "
"completes at 110, not 60", out and out[1] == T0 + 110 * MIN)
m = in_charge()
res, _, out = run(m, T0, 300, lambda i: 97.0, gate=False)
check("minutes with the gate closed do not count as 'no more charge'",
out is None)
m = in_charge()
_, t, _ = run(m, T0, 30, 98.0)
_, t, _ = run(m, t, 120, 98.0, gate=False)
res, _, out = run(m, t, 31, 98.0)
check("30 open + 120 closed + 31 open minutes complete (the closed ones "
"pause the count)", out and out[0].phase == HOLD)
print("2. SoC at the target completes at once")
m = in_charge()
r = m.tick(T0 + MIN, 100.0)
check("100 of 100 -> HOLD on that tick", r.phase == HOLD)
check("...with the old log line", "charge complete at 100 %" in r.events[0])
m = in_charge(cfg=cfg99)
check("99 of 99 -> HOLD", m.tick(T0 + MIN, 99.0).phase == HOLD)
print("3. a charge that runs out of time")
m = in_charge()
res, _, out = run(m, T0, CHARGE_TIMEOUT_MIN + 10,
lambda i: 60.0 + i / 55.0, step=1)
check("still rising 1 point per 55 min (never 60 flat) and near full when the "
"time is up -> counts as complete", out and out[0].phase == HOLD)
check("...with one plain line saying so",
out and len(out[0].events) == 1 and "charge time is up" in out[0].events[0]
and "counts as done" in out[0].events[0])
check("...and no failure is recorded", m.store.get_time("last_failed") is None)
m = in_charge()
res, _, out = run(m, T0, CHARGE_TIMEOUT_MIN + 10, 70.0)
check("a pack stuck at 70 % fails when the time is up",
out and out[0].phase == IDLE and out[0].failed == "charge")
check("...once: the failure is on one tick, and the pack is idle after",
m.phase == IDLE and m.tick(out[1] + MIN, 70.0).failed == "")
check("...with the old technical line and one plain line",
len(out[0].events) == 2 and "ABORT" in out[0].events[0]
and "did not finish" in out[0].events[1]
and f"{FAIL_BACKOFF_DAYS} days" in out[0].events[1])
check("...and last_failed is set, last_completed is not",
m.store.get_time("last_failed") == out[1]
and m.store.get_time("last_completed") is None)
print("4. the back-off after a failed cycle")
fail_at = out[1]
day = lambda n: fail_at.replace(hour=19, minute=0) + timedelta(days=n)
check("the next day at the start hour: no cycle (it would begin with a drain)",
not m.wants_start(day(1)) and m.tick(day(1), 70.0).phase == IDLE)
check("every day for 6 days: still no cycle",
all(not m.wants_start(day(n)) for n in range(1, 7)))
r = [m.tick(day(n), 70.0) for n in range(1, 7)]
check("...and tick() keeps the pack idle and silent",
all(x.phase == IDLE and not x.events and x.failed == "" for x in r))
until = m.backoff_until(day(1))
check("backoff_until() names the date, 7 days after the failure",
until == fail_at + timedelta(days=FAIL_BACKOFF_DAYS))
check("...it holds one minute before and is over at that minute",
m.backoff_until(until - MIN) == until and m.backoff_until(until) is None)
check("at 7 days, in the start hour, the pack wants to start again",
m.backoff_until(until) is None
and m.wants_start(until.replace(hour=19, minute=5)))
check("a forced start ignores the back-off",
m.force_start(day(1)) and m.phase == DRAIN)
m2 = in_charge()
run(m2, T0, CHARGE_TIMEOUT_MIN + 10, 70.0)
m2.force_start(day(2))
m2.tick(day(2) + MIN, 11.0)
res, _, out2 = run(m2, day(2) + 2 * MIN, 400, 100.0)
check("a forced cycle that completes ends the back-off",
out2 and out2[0].phase == HOLD)
m2.tick(out2[1] + 130 * MIN, 100.0)
check("...(the hold completes, last_completed is set)",
m2.store.get_time("last_completed") is not None
and m2.backoff_until(day(3)) is None)
m3 = in_charge()
m3.store.set_time("last_failed", T0)
m3.abort(T0 + MIN, "operator")
check("an operator abort is not a failure and starts no back-off",
m3.store.get_time("last_failed") == T0
and in_charge().store.get_time("last_failed") is None)
m4 = Maintenance(CFG, Mem())
m4.force_start(T0)
r = m4.tick(T0 + timedelta(minutes=721), 40.0)
check("a drain that times out is a failure too, with the same back-off",
r.failed == "drain" and m4.store.get_time("last_failed") is not None
and not m4.wants_start(day(1)))
print("5. only the minutes the pack was allowed to charge count")
m = in_charge()
# 5 min steps: one tick counts at most 5 min, so this is the same count as
# 1 min steps in a fifth of the ticks.
res, t, out = run(m, T0, CHARGE_TIMEOUT_MIN * 2, 70.0, gate=False, step=5)
check("72 h with the gate closed: not timed out", out is None and m.phase == CHARGE)
res, t, out = run(m, t, CHARGE_TIMEOUT_MIN - 5, 70.0, step=5)
check("...and 35 h 55 min open on top: still charging", out is None)
res, t, out = run(m, t, 10, 70.0)
check("...36 h of open time in all: the charge fails", out and out[0].failed == "charge")
m = in_charge()
WALL = T0 + CHARGE_WALL_TIMEOUT_MIN * MIN
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 10, 70.0, gate=False, step=5)
check("a gate that never opens still ends in a failure after 7 days (not before)",
out and out[0].failed == "charge" and WALL < out[1] <= WALL + 5 * MIN)
m = in_charge()
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 10, 98.0, gate=False, step=5)
check("...or in a complete charge when the pack is near full",
out and out[0].phase == HOLD and WALL < out[1] <= WALL + 5 * MIN)
m = in_charge()
res, t, out = run(m, T0, 10, 70.0)
before = m._trk["open_min"]
res = m.tick(t + 2 * timedelta(hours=1), 70.0)
check("a gap in the ticks (add-on down) counts for exactly 5 minutes (the cap)",
abs(m._trk["open_min"] - before - 5.0) < 1e-9)
m.tick(t + 2 * timedelta(hours=1) + 2 * MIN, 70.0)
check("...and a 2 minute step counts 2", abs(m._trk["open_min"] - before - 7.0) < 1e-9)
_t = t + 2 * timedelta(hours=1) + 2 * MIN
m.tick(_t - 10 * MIN, 70.0) # the clock steps back 10 min
check("...and a step back in time counts nothing (not minus)",
abs(m._trk["open_min"] - before - 7.0) < 1e-9)
print("6. restarts and old state files")
with tempfile.TemporaryDirectory() as d:
path = os.path.join(d, "state.json")
st = Store(path)
m = Maintenance(CFG, st)
m.force_start(T0)
m.tick(T0, 11.0)
_, t, out = run(m, T0, 60, 70.0, gate=False) # 60 min waiting
_, t, out = run(m, t, 40, 70.0) # 40 min charging
open_before = m._trk["open_min"]
# a fresh process on the same file
m_b = Maintenance(CFG, Store(path))
r = m_b.tick(t + MIN, 70.0)
check("a restart mid-charge keeps the open minutes (40 of 100 min; within "
"the 5 min save interval), not the 100 wall-clock minutes",
m_b.phase == CHARGE
and open_before - 6 <= m_b._trk["open_min"] <= open_before + 2
and m_b._trk["open_min"] < 60)
_, t2, out = run(m_b, t + 2 * MIN, CHARGE_TIMEOUT_MIN - 30, 70.0, step=5)
check("...so the timeout comes after 36 h in all, not 36 h from the restart",
out is not None and out[0].failed == "charge")
m = Maintenance(CFG, Store(path))
m.store.set_time("last_failed", T0)
m_c = Maintenance(CFG, Store(path))
check("a restart mid back-off keeps it (last_failed is in the file)",
m_c.backoff_until(T0 + timedelta(days=3)) == T0 + timedelta(days=7)
and not m_c.wants_start((T0 + timedelta(days=3)).replace(hour=19)))
check("...and the state file is plain JSON",
isinstance(json.load(open(path)).get("last_failed"), str))
old = {"phase": "charge",
"phase_started": (T0 - timedelta(hours=35)).isoformat(),
"last_completed": None, "last_start_attempt": None,
"auto": True}
path2 = os.path.join(d, "old.json")
json.dump(old, open(path2, "w"))
mo = Maintenance(CFG, Store(path2))
check("a state file from before this change loads with no failure and no "
"charge record", mo.backoff_until(T0) is None
and mo.store.get("charge_track") is None and mo.phase == CHARGE)
r = mo.tick(T0, 70.0)
check("...a charge in progress counts the hours it already ran (35 h)",
r.phase == CHARGE and 34 * 60 < mo._trk["open_min"] < 36 * 60)
res, _, out = run(mo, T0 + MIN, 120, 70.0)
check("...so it fails when the 36 h are up, as before",
out and out[0].failed == "charge")
# A record left by another charge (an add-on rolled back and forward
# again does not clear it) must not be read as this charge's.
stale = {"phase": "charge",
"phase_started": (T0 - timedelta(hours=2)).isoformat(),
"charge_track": {"since": (T0 - timedelta(days=30)).isoformat(),
"open_min": 2000.0, "flat_min": 59.0,
"best": 99.0, "at": None}}
ms = Maintenance(CFG, Mem(stale))
r = ms.tick(T0, 98.0)
check("a charge record from another charge is ignored: this charge counts "
"its own 2 h and its own best",
r.phase == CHARGE and 119 < ms._trk["open_min"] < 121
and ms._trk["flat_min"] == 0.0 and ms._trk["best"] == 98.0)
mi = Maintenance(CFG, Store(os.path.join(d, "none.json")))
check("no state file: due, no back-off", mi.due(T0) and mi.backoff_until(T0) is None)
print("7. two packs (N=2)")
a, b = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"), \
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b")
b.force_start(T0)
b.tick(T0, 11.0)
_, t, out = run(b, T0, CHARGE_TIMEOUT_MIN + 10, 70.0)
slot = datetime(2026, 10, 7, 19, 5, tzinfo=UTC)
check("B failed: B is backed off, A (due) is not",
out and out[0].failed == "charge" and not b.wants_start(slot)
and a.wants_start(slot))
check("...so A takes the slot, and B is not named as waiting for anyone",
arbitrate([a, b], slot) == ["", ""])
a.force_start(slot)
check("...and while A cycles, B is held as before",
"inverter-a" in arbitrate([a, b], slot + 3 * MIN)[1])
check("B's failure is under B's own keys, not A's",
b.store.get_time("last_failed") is not None
and a.store.get_time("last_failed") is None)
mst = Mem({"last_failed": T0.isoformat(), "phase": "idle"})
migrate_maint_keys(mst, "inverter-a", ["inverter-a", "inverter-b"])
check("going from one pack to two moves the back-off to the first pack",
mst.data.get(unit_key("inverter-a", "last_failed")) == T0.isoformat()
and "last_failed" in MAINT_UNIT_KEYS)
print("8. the Controller: gate, notification, status row")
class Hass:
def __init__(self, numbers, limits):
self.numbers, self.limits_by, self.calls = dict(numbers), dict(limits), []
async def number(self, entity, invert=False):
v = self.numbers.get(entity)
return None if v is None else (-v if invert else v)
async def limits(self, entity):
return self.limits_by.get(entity, (None, None, None))
async def set_number(self, entity, value):
return True
async def call(self, domain, service, data):
self.calls.append((domain, service, data))
return True
class Pub:
enabled = False
def publish(self, *a, **k):
pass
def close(self):
pass
OPTS1 = dict(setpoint_entity="number.sp_a", soc_entity="sensor.soc_a",
batt_entity="sensor.batt_a", meter_source="off",
meter_entity="sensor.grid", max_w=5000.0, gain=0.6, slew_w=6000,
deadband_w=15, target_grid_w=0, step_w=10, heartbeat_s=10,
stale_input_s=15, maintenance_discharge_w=2000,
maintenance_charge_w=2000, maintenance_enabled=True,
maintenance_soc_target=100,
price_now_entity="sensor.p_now", price_avg_entity="sensor.p_avg")
OPTS2 = {k: v for k, v in OPTS1.items()
if k not in ("setpoint_entity", "soc_entity", "batt_entity")}
OPTS2["inverters"] = [
dict(name="inverter-a", setpoint_entity="number.sp_a",
soc_entity="sensor.soc_a", batt_entity="sensor.batt_a", max_w=5000.0),
dict(name="inverter-b", setpoint_entity="number.sp_b",
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b", max_w=3000.0)]
def controller(opts, cheap, soc_a=70.0, soc_b=70.0):
p_now, p_avg = (0.05, 0.10) if cheap else (0.20, 0.10)
hass = Hass({"sensor.grid": 800.0, "sensor.soc_a": soc_a,
"sensor.batt_a": 0.0, "sensor.soc_b": soc_b,
"sensor.batt_b": 0.0, "sensor.p_now": p_now,
"sensor.p_avg": p_avg},
{"number.sp_a": (-5000.0, 5000.0, 1.0),
"number.sp_b": (-3000.0, 3000.0, 1.0)})
c = Controller(dict(opts), hass, Mem(), Pub(), stop=asyncio.Event())
for inv in c.inverters:
inv.dev_min, inv.dev_max = -inv.max_w, inv.max_w
c.auto = True
return c, hass
def one_cycle(c):
async def go():
await c.read_inputs()
await c.cycle()
asyncio.run(go())
def put_in_charge(c, which, hours_ago, open_min):
now = datetime.now(UTC)
m = c.maints[which]
m.store.set("phase", CHARGE)
m.store.set_time("phase_started", now - timedelta(hours=hours_ago))
m.store.set("charge_track", {
"since": m.store.get("phase_started"), "open_min": open_min,
"flat_min": 0.0, "best": 70.0,
"at": (now - timedelta(minutes=3)).isoformat()})
return m
def notes(h):
# Not the dismiss of PRICE-01's old fixed-tariff card, which every start sends.
# Only that dismiss: a `create` with the old id would still be counted.
return [x for x in h.calls if x[0] == "persistent_notification"
and not (x[1] == "dismiss"
and x[2].get("notification_id") == "goodwe_fixed_tariff_unused")]
for cheap in (True, False):
c, h = controller(OPTS1, cheap)
m = put_in_charge(c, 0, 5, 100.0)
one_cycle(c)
got = m._trk["open_min"] - 100.0
check(f"N=1, price gate {'open' if cheap else 'closed'}: the Controller "
f"{'adds' if cheap else 'does not add'} the 3 minutes since the last "
f"tick to the charging time (+{got:.1f})",
(2.5 < got < 3.5) if cheap else abs(got) < 0.01)
c, h = controller(OPTS1, True)
m = put_in_charge(c, 0, 40, CHARGE_TIMEOUT_MIN + 1)
one_cycle(c)
n = notes(h)
check("N=1: a charge past its time at 70 % ends in IDLE with ONE notification",
m.phase == IDLE and len(n) == 1
and n[0][2]["notification_id"] == "goodwe_maint_failed_battery"
and n[0][2]["title"] == "Battery cycle did not finish")
one_cycle(c)
one_cycle(c)
check("...and later cycles send no second one, and start no drain",
len(notes(h)) == 1 and m.phase == IDLE)
check("...the status page says when it waits until",
any(k == "Maintenance paused" and "Waits until" in v
for k, v in c.status_payload()["rows"]))
c0, _h0 = controller(OPTS1, True)
check("...and has no such row when nothing failed",
not any(k == "Maintenance paused" for k, v in c0.status_payload()["rows"]))
c, h = controller(OPTS2, True)
m = put_in_charge(c, 1, 40, CHARGE_TIMEOUT_MIN + 1)
one_cycle(c)
n = notes(h)
check("N=2: pack B fails, B alone is told, by name, under its own id",
c.maints[1].phase == IDLE and c.maints[0].phase == IDLE and len(n) == 1
and n[0][2]["notification_id"] == "goodwe_maint_failed_inverter_b"
and "inverter-b" in n[0][2]["message"])
check("...and its failure is on B's keys",
c.maints[1].store.get_time("last_failed") is not None
and c.maints[0].store.get_time("last_failed") is None)
# a site with no price entities and no fixed tariff: nothing holds the charge back
NOTARIFF = {k: v for k, v in OPTS1.items()
if k not in ("price_now_entity", "price_avg_entity")}
c, h = controller(NOTARIFF, False)
m = put_in_charge(c, 0, 5, 100.0)
one_cycle(c)
got = m._trk["open_min"] - 100.0
check("N=1, no tariff and no price entities: the gate counts as open, so the "
f"3 minutes count (+{got:.1f}) although `cheap` is false",
not c.cheap and 2.5 < got < 3.5)
c, h = controller(NOTARIFF, False)
m = put_in_charge(c, 0, 40, CHARGE_TIMEOUT_MIN + 1)
one_cycle(c)
check("...and a pack past its charging time there fails at once (not 7 days)",
m.phase == IDLE and len(notes(h)) == 1)
# a site with a price provider (TARIFF-11) and no fixed tariff: the provider's
# plan reaches only the Tariff row, never `cheap`, so no cheap window ever
# opens a grid top-up there. Like the site above, nothing gate-like holds the
# charge back, and the time counts.
PROVIDER = dict(NOTARIFF, price_provider="generic_dayahead", static_profile="")
c, h = controller(PROVIDER, False)
m = put_in_charge(c, 0, 5, 100.0)
one_cycle(c)
got = m._trk["open_min"] - 100.0
check("N=1, price provider and no fixed tariff: not a gate (`cheap` is never "
f"set from the provider), so the 3 minutes count (+{got:.1f})",
c._price_gated is False and not c.cheap
and c._charge_gate_open(c.inverters[0]) is True and 2.5 < got < 3.5)
def read(c):
asyncio.run(c.read_inputs())
c, h = controller(OPTS1, False)
read(c)
c.inverters[0].batt = -800.0
check("price gate closed but the pack is taking 800 W (sun): gate open",
c._charge_gate_open(c.inverters[0]) is True)
c.inverters[0].batt = -10.0
check("...closed and about idle: gate closed",
c._charge_gate_open(c.inverters[0]) is False)
c.inverters[0].batt = None
check("...no battery reading: gate closed", c._charge_gate_open(c.inverters[0]) is False)
c, h = controller(OPTS1, True)
read(c)
check("price gate open: gate open", c._charge_gate_open(c.inverters[0]) is True)
PROFILE = json.dumps({"periods": [
{"name": "day", "from": "07:00", "to": "22:00", "days": "all",
"eur_per_kwh": 0.29},
{"name": "night", "from": "22:00", "to": "07:00", "days": "all",
"eur_per_kwh": 0.19}]})
c, h = controller(dict(NOTARIFF, price_provider="off", static_profile=PROFILE),
False)
read(c)
check("a fixed tariff set up counts as a gate: outside its cheap hours a pack "
"that is not charging is closed, inside them it is open",
c._price_gated is True
and c._charge_gate_open(c.inverters[0]) is c.cheap)
import app.main as main_mod # noqa: E402
_real_gated, _calls = main_mod.static_gated, []
main_mod.static_gated = lambda o, now: _calls.append(now) or _real_gated(o, now)
try:
c._gated_key = None
read(c)
read(c)
read(c)
c._static_gated(c.o, datetime.now(UTC) + timedelta(hours=1))
finally:
main_mod.static_gated = _real_gated
check("...worked out once an hour, not on every tick (3 reads in one hour = 1 "
f"build; a new hour = 1 more): {len(_calls)} builds",
len(_calls) == 2 and c._price_gated is True)
# the save timer is reset on a phase change
mm = in_charge()
mm.tick(T0 + MIN, 70.0)
saved_before = mm._trk_saved
mm.abort(T0 + 2 * MIN, "operator")
check("leaving CHARGE resets the save timer along with the record",
saved_before is not None and mm._trk is None and mm._trk_saved is None)
print("9. the words")
en, nl = messages.maint_failed("charge", 7), messages.maint_failed("drain", 7)
for n_ in (en, nl):
print(" " + n_.title + " | " + n_.body + " | " + n_.body_nl)
check("EN charge text", en.body == "The battery did not fill up, so its cycle "
"stopped and tries again in 7 days.")
check("EN drain text", nl.body == "The battery did not empty, so its cycle "
"stopped and tries again in 7 days.")
check("NL texts", en.body_nl == "Batterijcyclus niet afgerond. De batterij "
"raakte niet vol, dus de cyclus is gestopt en probeert het over 7 dagen "
"opnieuw." and nl.body_nl.endswith("raakte niet leeg, dus de cyclus is "
"gestopt en probeert het over 7 dagen opnieuw."))
check("the notification carries EN, NL and the Details line, in that order",
re.fullmatch(r"The battery .*\n\nBatterijcyclus .*\n\nDetails: .*",
en.data()["message"], re.S) is not None)
check("the DOCS section and table row exist",
"### Battery cycle did not finish" in (HERE / "DOCS.md").read_text()
and "goodwe_maint_failed_<name>" in (HERE / "DOCS.md").read_text())
check("no new option: the numbers are constants",
(CHARGE_NEAR_FULL_PCT, CHARGE_STALL_MIN, FAIL_BACKOFF_DAYS)
== (3, 60, 7))
print()
if fails:
print(f"{len(fails)} FAILED")
for f in fails:
print(" -", f)
sys.exit(1)