SAFETY-37: correct a wall-clock tick and a false size claim
Two blocking findings from review, both in prose, both corrected at every
site.

1. "trips on tick 7" was not what the fixture prints. It prints 11, five
   runs out of five, and the developer's own report says 11. ⚠️ But the
   deeper problem is that the number should never have been quoted: the
   tick is counted on the WALL CLOCK inside cycle() (hold_s 2 s, ticks
   0.20 s apart), so it is load-dependent - 7 is what a box slow enough
   to stretch each tick to ~0.29 s would print - and nothing pins it.
   The DECISIONS transcript now says 11 because it is a transcript of a
   run; the CHANGELOG stops quoting a tick at all and states the
   checkable thing instead: it trips without the gate and never with it,
   which part 3 grades.

2. ⚠️ SURVIVOR 2's SIZE CLAIM WAS FALSE FOR ONE OF THE TWO CONSUMERS THIS
   CARD EXISTS TO PROTECT. It read "one contributing at most 250 W to a
   loop whose reporting floor is 700 W" at three sites. That bounds the
   COMMAND. Once the register is frozen its REPORTED value is unrelated
   to the command - which is exactly HW-01's shape: commanded ~0 W,
   register stuck on the last large number.

   Measured in review: a unit frozen at -1200 W beside a healthy +900 W
   sibling yields circulating_w = 1800 W against the 700 W floor, 2.6x
   OVER, with no gate armed.

   So the scoping is TRUE for the per-unit sign check and FALSE for
   circulation. Corrected to say exactly that, and the circulation
   consumer's exposure below MOVE_W is now recorded as a KNOWN GAP rather
   than a covered one.

   It survived because part 9's S2 check asserts only `not stale` and
   part 4 pairs the frozen unit with a RESTING sibling
   (circulating_w([A_FROZEN_W, 0.0]) == 0.0) - neither grades the size
   sentence.

No behaviour change. Full suite: 22 passed, 0 failed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 12:35:27 +02:00

22 KiB
Raw Permalink Blame History

SAFETY-37 — the freshness policy, and the one sentence in the card that had to be rewritten

Status: DECIDED 2026-09-06. A per-unit reading that has stopped following its own command is reported to its consumers as None, never as a held number. The verdict is a conjunction, not an age threshold, and this document records why an age threshold is not available at this layer — which is the one place the card's wording could not be implemented as written.

Filed with SAFETY-37. Card 6a9a7eda7932387c3acbd700, scope widened by the architect pass of 2026-09-06 to carry the single policy for TEL-06 and TEL-08 as well.

Every figure below was measured or read out of this repository on 2026-09-06 and is re-derived by test_freshness.py on every run. Where a number is carried forward from an earlier measurement, the section and the date it was taken are given at the number.


0. The three faces, and which one this card built

where the defect this card
Layer 1 — goodwe/master/goodwe-master-stage4-failsafe.yaml:690 the ingest-age veto tests the VALUE of sensor.goodwe_p1_sample_age, not its arrival. A dead publisher freezes it at a healthy number and the veto can never fire not touched. It is firmware, behind a flash. §5 says what it owes
The add-on — app/hass.py:69-82 returns a held value as a value. Nothing separates "read 40 %" from "still says 40 % because nothing updated it" built here
The evidence — HW-01 SoC held 40 % for 6 h 25 m while the pack drained to its floor, every detector reading healthy the case the policy is answerable to

The two consumers the card names — SAFETY-30's per-unit sign check and SAFETY-31's circulating-power sensor — both read Inverter.batt (register 0x0518) and neither had a freshness gate of any kind. Both already do the right thing with a None: watchdog.SignWatchdog.evaluate clears its window on a None measurement, and circulation.circulating_w returns None for a roster with a missing term, which clears that window too. Neither could ever receive one. The gate is the piece that was missing between the shipped read and the shipped checks, which is why the change to each consumer is zero lines.


1. ⚠️ The sentence that had to be rewritten, and why saying so is the finding

The card says: "A pack legitimately resting at 40 % and a dead sensor reading 40 % are the same number; only arrival separates them."

For a signal this add-on polls out of Home Assistant's state cache, arrival does not separate them, and cannot. read_inputs() runs about once a second (run_control()'s await asyncio.sleep(1) bounds the loop body), and while the entity exists Home Assistant answers 200 with a number whether or not the publisher behind it is alive. So both members of the pair arrive, identically, for ever. test_freshness.py part 1a builds an arrival-age gate and grades it: the age since arrival is 0.0 s at every instant of both runs. A threshold on it is a threshold that can never fire — which is TEL-06's own defect rebuilt one layer up.

The other half of the card's rule survives intact and is honoured absolutely:

⚠️ Home Assistant's last_updated does not move when a value is rewritten unchanged, so it cannot be the source of truth.

Neither does last_changed, and this project measured on the ENV-01 rig (70 s of a frozen meter) and independently against the live house that last_reported does not advance on a repeat on either serialiser either — p1.HomeWizardLocalSource's docstring records both. app/freshness.py reads no Home Assistant timestamp at all. Every clock in the verdict is time.monotonic() inside this process, stamped at the instant an arrival carried a different number. That is what "arrival-stamped" can mean here, and it is graded (part 1a asserts the module's body contains no last_updated).

So the criterion was rewritten rather than approximated: a reading is stale when it has not moved through a change it was obliged to follow. The obligation, not the age, is what separates the pair.


2. The verdict

STALE  ⟺  unchanged for ≥ 35.0 s
          AND |standing command now| ≥ 250 W
          AND |standing command now − standing command when the reading
               last changed| ≥ 250 W

Latched: only an arrival carrying a different number clears it.

0x0518 is the inverter reporting itself — r = 0.998 with battery power against r = 0.09 with the real meter (goodwe/NOTES.md §3.3) — and it tracks its own command: command and actual agreeing within 4 W once settled (§5.10, measured 2026-08-22), the register dithering ±1 W while holding (§5.11, same day). A unit told to move 250 W and still answering the same integer watt is not tracking.

2.1 Why a bare "unchanged for N seconds" threshold is not available

Measured, not feared. Replaying the committed 30-day capture of this house's own 1 W-resolution power entity — scenarios/p1-net-30d-2026-08/, 485,841 samples straight out of Home Assistant's recorder, where a row exists only when the state string changed, so the gap between two rows is the unchanged duration every consumer saw:

longest unchanged run over 30 days 263.2 s (held −899.0 W, 2026-08-11 17:04)
runs ≥ 35 s 10 of 485,840 (0.0021 %)
runs ≥ 17 s 386 of 485,840 (0.0794 %)

A real power figure at 1 W resolution held one value for four and a half minutes with nothing whatever wrong. So an unchanged threshold free of false positives must be over 263 s — and 263 s is 3.5× too slow to protect a consumer that trips at 75 s. There is no admissible threshold. The conjunction is not a refinement; without it the card has no implementable verdict.

⚠️ That is the METER's register, not 0x0518, and it is used as a surrogate and named as one. No 30-day capture of the inverter's own power exists — it is not in the recorder export. The single thing this measurement is used for is the statement above: that the legitimate unchanged duration of a power entity in this house is minutes. It is not used to set the bound.

⚠️ And every one of those long runs happened under an unmoving load — the worst is 263 s of a steady −899 W export, a house doing one thing. That is why the conjunction keys on command travel: none of them arms it.

2.2 Why the magnitude term exists — a surviving mutation put it there

Deleting abs(standing_w) < move_w from _grade() left every check in the first draft green, because in all of them a command that had travelled 250 W had also ended up above 250 W. The case that separates them is a site being brought to rest: the write path is serialised, so a register can reach its new value on the same read at which the old command is still standing — standing_at_change then captures 1300 W, the site is commanded to 0 W, and the travel term alone reads 1300 W of unfollowed command for as long as the site rests. It would call a perfectly truthful +5 W reading dead. The magnitude term is what says a site at rest is not owed movement, and part 4 now grades it.

The hole that term leaves cannot mislead either consumer, which is why it is the right trade: a unit commanded under 250 W is one watchdog.disagrees() is False for whatever the measurement says, and a frozen term beside a live unit that is itself resting nets to zero circulating power rather than to a false alarm. Both halves are asserted, not argued.


3. The bounds — one per signal, each with its derivation

⚠️ One constant for both signals would be useless on SoC or trigger-happy on power, which is the third clause of the policy. freshness.BOUNDS carries them as data with a wired column, and test_freshness.py part 7 walks the AST of every shipped module to check that column tells the truth.

3.1 batt — 0x0518, S16, 1 W, published every 10 s — WIRED

Floor, 17.0 s — the fastest a healthy register can be obliged to have answered. Three terms, each read out of this repository:

source
6.0 s the plant goodwe/NOTES.md §5.9, measured 2026-08-22 with the poll temporarily at 1 s: 26 W at +1.43 s, 469 W (94 %) at +3.34 s, settled 507 W at +6.05 s
10.0 s the publisher firmware/goodwe-master.yaml:181, update_interval: 10s on the modbus_controller carrying both 0x0518 and 0x050E
1.0 s this add-on's read period main.run_control()'s await asyncio.sleep(1)

Ceiling, 75.0 s — the tighter of the two consumers, both read out of the shipped config.yaml: circulation_hold_s 75 (line 512) and unit_sign_disagree_s 85 (line 451). A gate slower than its consumer hands over the frozen number and explains afterwards.

Chosen: 35.0 s. The admissible band [2 × 17.0, 0.5 × 75.0] = [34.0, 37.5] contains four integers, and the band is what is derived — 35 is a choice inside it, deliberately not 30 (that is validate.FIRMWARE_INGEST_VETO_S, and would read as a borrowed constant nobody re-derived) and not 60 (round). Part 6 computes both ends from config.yaml and goes red if an operator default moves: drop circulation_hold_s to 60 and this fails.

MOVE_W = 250 W is the largest admissible value, not a sensitivity preference. The gate must arm everywhere a stale reading could mislead a consumer; the earliest either consumer speaks is unit_sign_disagree_w, 250 W (config.yaml:450), because below that watchdog.disagrees() is False whatever the measurement says. Taking the ceiling of the admissible range minimises spurious arming. It is pinned to config.yaml by part 6, not to a literal.

3.2 soc — 0x050E, U16, 1 %, published every 10 s — STATED, NOT WIRED

SoC cannot use the conjunction above. A pack resting at its floor holds one percent for hours with nothing wrong — the card's own example — and the standing command says nothing about it, because 0 W is exactly what a rested pack is given. The obliged movement for SoC is energy, not command travel: one percent of pack A is ≈ 153.6 Wh (15.36 kWh nominal, goodwe/NOTES.md §1.1b's table — ⚠️ NOMINAL and FROM DATASHEET, not a measured usable capacity), so at pack A's 5000 W ceiling one percent takes at least 110 s, and at a realistic 1000 W about 553 s.

So the bound is "SoC unchanged while ∫|battery power| dt since its last change exceeded K × 153.6 Wh", and K cannot be chosen from anything written down today. Wiring it with a guessed K would be a gate that fires on a rested pack, which is the hazard, not the fix. Freshness takes its obligation term from the caller precisely so an energy integral can be handed in where command travel is handed in for batt — TEL-08 needs no second mechanism.


4. What changes on a running install

before after
healthy register, N=1 value reaches consumers identical — 60 reads of a dithering register under a reversing command, asserted in part 5
healthy register, N≥2 value reaches consumers identical
frozen register, N=1 reads as a healthy measurement, for ever site stops: inputs_ok False → stale_input_s hold → 0 W, and keeps commanding
frozen register, N≥2 per-unit sign check false-trips at 85 s and parks a healthy inverter; circulation sensor reports a loop that is not happening both consumers get None, both windows clear

⚠️ The N=1 row is a behaviour change on the roster that is running in a house today, and it is named rather than hidden. It is also the point of the card: HW-01 was a one-inverter site. The direction it fails in is the safe one — a false verdict commands 0 W and keeps commanding (§11.1 rule 1), behind the existing stale_input_s hold, and clears itself on the register's next move.

The counterfactual is run, not argued. test_freshness.py part 3 drives real cycle() calls at N=2 with A's register frozen at −1200 W and B's live at +900 W, the command travel produced by the shipped compute() and allocator:

standing on A: [0, 445, 890, 1335, 1335, ...]      (the shipped control law)
gated       : sign trip tick=None   circulating_w=[1800, 1800, 1800, None, None, ...]
counterfact : sign trip tick=11      circulating_w=[1800, 1800, 1800, 1800, 1800, ...]

5. What TEL-06 and TEL-08 still owe

TEL-06 — layer 1, Blocked, and nothing in this card can reach it. The ESPHome veto tests the value of sensor.goodwe_p1_sample_age. This policy lives in the add-on, on the other side of a flash, and cannot help. What TEL-06 owes is the same mechanism inside the firmware: a millis() stamp taken when the setpoint/age entity is written, and a veto on millis() − last_write_ms rather than on the published number. It is narrowed to that one substitution — the policy question ("arrival, not value") is answered here; the remaining work is a firmware stamp and a flash, which is a supervised human step.

TEL-08 — stale SoC. It owes exactly three things, and no mechanism:

  1. a measured usable capacity for pack A (or a defensible bound on it) — the 153.6 Wh per percent above is nominal and from the datasheet;
  2. the energy integral since the reading last changed;
  3. the constant K — how many percent-equivalents of throughput must pass before an unmoved SoC is a fault.

It should consume freshness.Freshness with BOUNDS["soc"] filled in, not restate the policy. The row is already in the table with wired=False and the reason, and part 7 goes red the day that column stops being true.

⚠️ Neither of them, and not this card, closes HW-01's whole class. See §6.


6. Known survivors, with their size

Graded in test_freshness.py part 9, so they are residuals rather than surprises.

# kind what survives size
1 false positive an inverter physically unable to follow — saturating, thermally derating, or a BMS refusing a charge — is declared stale while telling the truth one spurious site stop, behind stale_input_s, self-clearing the moment the register moves. It cannot drive the battery anywhere
2 miss a register frozen under a command that never travels 250 W is never detected, for 400 s or for ever ⚠️ scoped for ONE consumer, NOT both, and the earlier claim here was wrong. TRUE for the per-unit sign check: no such check can speak about that unit (unit_sign_disagree_w = 250 W). FALSE for circulation. "Contributing at most 250 W" bounds the COMMAND; once the register is frozen its REPORTED value is unrelated to the command, which is exactly HW-01's shape - commanded ~0 W, register stuck on the last large number. Measured: a unit frozen at −1200 W beside a healthy +900 W sibling yields circulating_w = 1800 W against the 700 W floor, 2.6× over, with no gate armed. Found in review; part 9's S2 check asserts only not stale and part 4 pairs the frozen unit with a RESTING sibling, so neither graded the sentence
3 miss — the largest a dead publisher whose last values alternate, or a cache replaying two old samples, never starts the unchanged clock at all this gate detects a value that STOPPED; it cannot detect a value that is WRONG. Nothing in this add-on can. TEL-06's arrival stamp inside the firmware is the only layer that could

Recorded because it looks like a survivor and is not: a publisher failure that freezes both registers is caught on both units independently, on each unit's own command travel and each unit's own number.


7. Mutation record — 2026-09-06

tools/mutation_run.sh's rule, honoured on every run: purge first (count printed, 0 remaining), tree mounted :ro, python3 -B, fingerprint the tree, and fingerprint again after the revert. Clean tree app/freshness.py sha256:f40fa3e8819014ce / 20,065 B, app/inverter.py 7e760c6e8cdfa5b7 / 30,778 B, app/main.py 7d7ff4ba0697ea64 / 238,535 B. Each mutant graded by test_freshness.py + test_inverter.py.

# mutation file Δ B result
M0 none (control) freshness +0 green — the harness is not red on everything
M1 reading() returns self.last unconditionally freshness −24 red, 3 named checks
M2 drop the command-travel term freshness −59 red
M3 drop the magnitude term freshness −54 SURVIVED, then red — §2.2. This is the finding
M4 latch never holds freshness +13 red, 3 named checks
M5 bound 90 s (slower than both consumers) freshness +0 red
M6 bound 10 s (under the physical floor) freshness +0 red
M7 MOVE_W 700 W freshness +0 red, on part 6's config.yaml pin
M8 the wiring in _read_unit removed main −5 red, 3 named checks
M9 reset the unchanged clock on every arrival (value-stamped) freshness −43 red
M10 standing_w() drops last_write inverter −73 red, and takes test_inverter.py with it
M11 standing_at_change refreshed on every arrival freshness +121 ⚠️ DISCOUNTED — the mutant does not parse
M11b the same defect, written parseably freshness +105 red
M12 BOUNDS["soc"].wired = True — the table lies freshness −1 red
M13 the wrong signal submitted (inv.soc for inv.batt) main +4 red, and test_inverter.py too
M14 one Freshness shared by every unit inverter +29 red
M15 latch cleared by a failed read freshness +31 SURVIVED, then red — see below

⚠️ M5, M6 and M7 are +0 B, which MUTATION.md names as the risky delta. All three are reds, which is the direction stale bytecode cannot fabricate, and every run purged with the count printed and graded a :ro tree that physically cannot hold a cache.

⚠️ M11 IS NOT A RESULT AND IS NOT COUNTED. Its edit dedents a statement into the middle of an if body, so the module raises IndentationError at line 312 and both files go red without a single check being evaluated. Verified by ast.parse rather than assumed. M11b is the same defect written so it parses, and it is a real red.

The two survivors, and what each one taught

M3, the magnitude term — see §2.2. Two terms of a conjunction that move together in every fixture are one term as far as the checks are concerned. Recorded as MUTATION.md habit 17, twelfth instance of "a check whose DATA cannot reach the failure it names".

M15, the latch cleared by a failed read — found only because the sweep went looking for what the checks would NOT see. No fixture had ever injected a read failure while latched, and it matters: a stale verdict stops the site, the site is then commanded 0 W, and one unreachable-Home-Assistant read would drop the latch into a state where the conjunction is no longer armed — so the held −1200 W would come back to the consumers on the very next successful read. Part 4 now grades exactly that and M15 is red.

And one process defect worth more than the ledger

One mutation's container run overran a two-minute command budget and the wrapper was killed between the edit and the revert, leaving app/freshness.py mutated on disk. Nothing announced it; the next mutation's harness cheerfully fingerprinted and graded the mutant plus a second mutation. It was caught by comparing the tree fingerprint against the recorded clean one, restored, and verified back to byte and sha256 before anything else ran. Same defect as stale bytecode, different cause. Recorded as MUTATION.md habit 18: fingerprint after the revert, not only before the run.

A third, in this file's own fixture

M2 originally reported "red" with no named check behind it. The mutant makes the FRESH run stale, so test_freshness.py's own diagnostic print(f"… {sorted(set(_fresh_read))}") raised TypeError comparing None with a float before check one ran. MUTATION.md's reporting rule is "which suite went red, and on which named check", and a print that can crash first destroys exactly that. Sorted with key=str now; M2 reports its check.

Re-verified at the committed head

The 16-row sweep above graded test_freshness.py as it stood when each mutation ran; the two closures (M3's part-4 check, M15's failed-read check), the key=str fix and the wall-clock hardening all landed afterwards. So six mutations were re-run against the exact tree that is committed — test_freshness.py sha256:a62f3e1f1ac856cf, 44,913 B:

# result at head
M0 control green
M2 drop the command-travel term red, on part 1's "FRESH AND UNCHANGED is not stale"
M3 drop the magnitude term red, on part 4's magnitude check
M8 wiring removed red, on three named checks in parts 2 and 3
M11b standing_at_change drifts red, on three named checks in part 1
M15 latch cleared by a failed read red, on part 4's failed-read check

The other ten are unaffected by those edits: each is red on a check in parts 1, 2, 4, 6, 7 or 9 that none of them touches, and a mutation red on one check cannot be made green by adding another.

The wall clock, which part 3 cannot avoid and therefore measures

The freshness verdict runs on an injected monotonic clock and is deterministic. The sign watchdog inside cycle() cannot be injected, so part 3 runs against the real one — which is CI-06's failure mode exactly (test_peakguard.py answered two checks with the wall clock, flaked at ~20 %, and cost a wrong merge diagnosis). So the margin is measured and asserted rather than assumed:

gate closed after 0.61 s of WALL clock, against the 2 s watchdog window (3.3x margin)

If a loaded machine ever narrows that, the check fails naming the number, which is the difference between "the box was slow" and "the code is broken".