checks / unit (pull_request) Canceled after 0s
Two conflicts, both predicted, both mine as the later merger. app/main.py - #12 inserted `await self.check_output_clamp()` on the line immediately above `await self.check_meter_frozen()`, so its hunk abuts my comment correction. Resolved so EACH CALL CARRIES ITS OWN BOUNDARY, because the two guards do not share one: - check_output_clamp() reads `self.clamp_last`, which is None until write_setpoint() has run, so its boundary IS the write; - check_meter_frozen() grades `self.target`, assigned further up, so its boundary is the assignment. Letting my correction generalise across both would have been worse than the vague comment it replaces, because it would read as deliberate. The AST of app/main.py is identical to merged release/1.0 (+1251 bytes, all comment). test_freeze.py - #12 independently added `frozen_notes()` keyed on the same id. `notes_of()` subsumes it: same id, plus the title fallback that keeps the id's own check independently falsifiable, plus `all_notes_of()` for claims about the whole surface. THE THREE SURFACE-WIDE ASSERTIONS, DECIDED ONE AT A TIME. Measured on the merged tree: scenario surface ids freeze frozen meter, railed command 2 frozen + clamp 1 TEL-05 converged, -14.2 W 0 - 0 moving meter, a real 8 kW load 1 clamp 0 uncovered transport, no unchanged_s 1 clamp 0 - the wiring scenario STAYS SURFACE-WIDE and now asserts exactly TWO alarms with BOTH IDS NAMED. The answer to "is this still meant to raise one alarm" is no, it raises two, and a third guard has to come back to this line. That is the one assertion in the file that accounts for the controller's entire alarm output; - the CONVERGED case stays surface-wide and stays silent: at the operating point the whole add-on should have nothing to say, that is still true, and narrowing it would give away a real property; - the other two NARROW to notes_of(). The clamp alarm there is correct and is SAFETY-03's subject: a real 8 kW load does drive the loop past the rating, and an uncovered transport does not stop it. Asserting whole-surface silence would make this file fail whenever another guard correctly does its job. Each still owns the load-bearing half - THE FREEZE DETECTOR SAID NOTHING - and the surface is PRINTED so a reader sees what else fired without this file grading it. Re-verified on the merged tree: M1 RED 4, M2 RED 5, M3 RED 3 + RED 2, N6 RED 1, N3 green (correctly), N8 RED 4, R1 RED 2, R2 RED 1. All nine suites green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC