Files
goodwe-addon/goodwe_controller/CHANGELOG.md
glenn schrooyenandClaude Opus 5.5 1ad4d3a5bb
checks / unit (pull_request) Successful in 8m5s
PKG-18: cut 0.12.0, so TEL-12's pv_entities can reach an installed 0.11.0
One runtime merge since 0.11.0 (cccb2fa): TEL-12 (#116), a new optional
list option `pv_entities` beside `pv_entity`. Option surface 76 -> 77, so
a minor bump. config.yaml version and a closed `## 0.12.0` section only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 22:59:44 +02:00

6597 lines
422 KiB
Markdown
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Changelog
## 0.12.0
**A MINOR BUMP FOR ONE NEW OPTION: `pv_entities` ([[TEL-12]]), for sites with
more than one PV inverter.** The option surface moves **76 keys -> 77**,
`options:` and `schema:` in step. 0.11.0's `pv_entity` takes one entity; a roof
with two or three inverters, each publishing its own power sensor into Home
Assistant, could only record one of them. `pv_entities` is a list, and the
Configuration tab renders it as a repeatable field, so you add your second and
third inverter there rather than in YAML.
⚠️ **UNSET, NOTHING CHANGES.** `pv_entities` ships as `[]`, which is what every
install that presses *Update* lands on, and empty means "use `pv_entity`" - so
an install with no PV entity still has no PV channel, and an install with one
`pv_entity` keeps exactly the single-entity channel 0.11.0 gave it. **No rule was
added to `validate.py`**, which mentions neither key, so **a stored options blob
that starts the add-on on 0.11.0 starts it on 0.12.0**. There is no
`SystemExit(78)` to plan around on this hop.
⚠️ **IT IS INSTRUMENTATION ONLY, NOT A CONTROL INPUT.** `app/control.py`,
`allocator.py`, `arbiter.py`, `peakguard.py` and the watchdogs are not in this
release's diff; the runtime files that move are `app/pv.py`, `app/main.py`,
`app/mqtt.py`, `config.yaml` and `translations/`. `tools/tel11_pv_trace.py`,
extended for this card, hashes the controller's decisions on 0.11.0 and on this
tree: the control document is **`846a10a5b89e…` with PV unset and with one
entity, on both trees** - the same hash TEL-11 recorded - and with a
three-entity roster it equals each grid world's unset document, including every
cell where one inverter is dead. Neither the total nor any partial total reaches
a decision. With PV unset or with one entity, the **telemetry** is byte-identical
to 0.11.0's as well.
Contents of this release, in merge order since 0.11.0 (`cccb2fa`):
| | |
|---|---|
| `f863eca` | TEL-12 - several PV inverters, and one absent member is an absent TOTAL **⚠️ NEW OPTIONAL OPTION, EMPTY ON EVERY EXISTING INSTALL** |
### TEL-12 — `pv_entities`: the PV channel for a roof with several inverters
**WHAT TO DO ON A SITE WITH MORE THAN ONE PV INVERTER.** List every inverter's
power sensor under `pv_entities`:
```yaml
pv_entities:
- sensor.pv_east_power
- sensor.pv_west_power
- sensor.pv_garage_power
```
`sensor.goodwe_pv_power` then carries the **site total**. Each entity's own
`unit_of_measurement` is read, so a kW inverter beside a W one sums correctly;
a sensor with no unit or a non-power unit is refused by name on the status
page, as in 0.11.0.
⚠️ **`pv_entities` REPLACES `pv_entity` - IT DOES NOT ADD TO IT.** When the list
is set, `pv_entity` is not read at all. **If you are upgrading from 0.11.0 with
`pv_entity` already set, the inverter it names must also be in the list**, or it
drops out of the total. Put it in the list and it is **counted once**, not
twice - that is why the rule is replacement: under a union, the natural action
(put all your inverters in the new field) would double-count the one the old
key already names. While both keys are set the status page shows a caution
saying which one won - *"`pv_entities` is set, so `pv_entity` is IGNORED - the N
entities in the list are what is summed. Clear `pv_entity` to remove this
caution"*. It is a caution, never a refusal to start and never a NOT READY row.
A repeated id inside the list is also counted once.
⚠️ **IF ANY CONFIGURED PV ENTITY IS ABSENT, THE PUBLISHED TOTAL IS `unknown` -
NOT THE SUM OF THE ONES THAT ANSWERED.** Three inverters configured and one
`unavailable`: `sensor.goodwe_pv_power` goes to `unknown` and the recorder
stores a **gap**. The sum of the other two would be a smaller number
indistinguishable from a real one, and a week later it would read as *"there
was less sun than there was"* - the conclusion this channel exists to test
rather than to manufacture. **A gap in the history, never an understated
number.** The status page, read live, still gives you the diagnostic: `PV —`
plus a caution that says there is **no site total**, names the missing entity
and its reason, and lists what the others reported. An inverter honestly
reporting **0 W** is summed, not treated as absent - shading and nightfall are
real zeros.
| what happened | `sensor.goodwe_pv_power` | the status page |
|---|---|---|
| neither key set | the entity does not exist | no row |
| all three answer, 1200 W + 2.1 kW + 450 W | `3750.0` | `PV 3 750 W` |
| all three answer, one of them `0 W` | the sum of the two others | the sum |
| one (or more) `unavailable` / missing / bad unit | `unknown` - a recorder gap | `PV —` + a caution naming what is missing |
⚠️ **THE FIX FOR A MISSING INVERTER IS NOT A TEMPLATE SENSOR THAT SUMS THEM.**
You can still point `pv_entity` at one if you prefer, but a template sensor
summing an `unavailable` source yields the partial total silently - the same
defect one layer down, where this add-on cannot see it or report it.
**WHY A SECOND KEY, RATHER THAN MAKING `pv_entity` A LIST.** Because an 0.11.0
install that has `pv_entity` set would not start. Measured against Supervisor
**2026.08.0** by `tools/supervisor_shape_probe.py` §G: with `pv_entity` declared
as a list, the string an 0.11.0 install has persisted is refused -
`Invalid list for option 'pv_entity'` - and a shipped `[]` default does not
rescue it, because the Supervisor's merge keeps your stored string. The one
single-key spelling that accepts both shapes, `match(.*)?`, validates nothing
(it accepts the integer `417`) and renders as a plain text box, so you could not
add a second inverter in the UI. So `pv_entity` stays a string, and the same
probe shows an 0.11.0 options blob - `pv_entity` set, no `pv_entities` key at
all - validating against this version untouched. ⚠️ **Rolling back to 0.11.0 is
also safe**: a schema without `pv_entities` drops the key with a warning and
leaves `pv_entity` standing.
**Why it matters now:** [[OPT-10]] needs a week of PV history to attribute the
surplus that left the reference site while the pack had room, and that site has
several PV inverters. The week starts when the site total is recorded.
**Full account: `DECISIONS/TEL-12-several-pv-inverters.md`, with the operator's
version under "Several PV inverters" in `DOCS.md`.**
### If you are crossing from a version older than 0.10.0
⚠️ **THIS SECTION IS NOT THE ONE THAT CAN REFUSE YOU - `## 0.10.0` BELOW IS.**
Updating installs 0.12.0 in one step, so every validator rule added in
0.8.0, 0.9.0 and 0.10.0 arrives at the same moment. Two of them can refuse a
config nobody has edited: [[SAFETY-39]]'s **rule 10** (added in 0.8.0) against
0.7.0's shipped default `slew_w: 1000` - the ceiling is **555.6 W** on a 5000 W
rail - and [[TARIFF-07]]'s three withdrawn `price_provider` ids,
**`engie_dynamic`, `totalenergies_dynamic` and `eneco_eddy`**, each still
refused by name at startup on 0.12.0. Neither is new here, and a site already on
0.10.0 or later has already met both. **The full account of both, including
what to set instead of each withdrawn id, is in `## 0.10.0`**, which withdrew
them and is not superseded by this section.
`tools/predeploy_check.py` checks your live options against this version's
validator before you press *Update*, and on this tree reports a real version
change from 0.11.0. ⚠️ **Pass it the bare options dict - the `data.options`
object - NOT the whole `ha apps info --raw-json` document.** Handed the wrapped
export it currently prints CLEARED while having checked nothing ([[SAFETY-60]],
open). Extract the options first, e.g. `jq '.data.options'`.
## 0.11.0
**A MINOR BUMP, AND ONE NEW OPTION IS THE WHOLE REASON FOR THE SECOND DIGIT:
`pv_entity` ([[TEL-11]]).** The option surface moves - **75 keys -> 76**,
`options:` and `schema:` in step - which is the same test 0.8.0, 0.9.0 and
0.10.0 were each cut on. ⚠️ **AND UNLIKE 0.10.0, NOTHING HERE CAN REFUSE A
STORED OPTIONS BLOB.** No key was removed, no default moved, no enum widened,
and **no rule was added to `validate.py`** - the validator does not mention
`pv_entity` at all, because nothing else reads it and it cannot conflict with
anything. The new key is `str?` - **note the trailing `?`, it is OPTIONAL** -
with an `options:` default of `""`, so a blob written on 0.10.0 or 0.10.1 does
not carry it, the Supervisor's merge supplies the empty string, and the empty
string is *off*. ⚠️ **A stored options blob that starts the add-on on 0.10.1
starts it on 0.11.0. There is no `SystemExit(78)` to plan around on this hop**,
and a site that presses *Update* and changes nothing else gets an add-on that
behaves exactly as its 0.10.1 did.
⚠️ **WHAT YOU ARE ACTUALLY DECIDING, IN ONE LINE EACH. TWO TICKETS HERE ARE
OBSERVABLE ON AN INSTALLED ADD-ON, AND NEITHER CHANGES A WATT.**
* [[SAFETY-56]] - **three messages stop naming your hardware as the fault** in a
state where the add-on cannot tell a dead register from a battery that is
simply empty at its BMS floor. **Text only; the behaviour is measured
byte-identical.** If you have ever opened Developer Tools because the add-on
told you a sensor had failed, and found the sensor working, this is that
defect. On the reference install the state it misdiagnoses arrives on most
nights and on every cloudy morning after a deep discharge.
* [[TEL-11]] - **one new optional key, `pv_entity`, and nothing whatever happens
until you fill it in.** Set it and the add-on records what your solar is
producing beside what the meter and the battery are doing. ⚠️ **It is not a
control input and it does not change what the loop does.**
⚠️ **THERE IS NO CONTROL-LAW CHANGE IN THIS RELEASE, WHICH IS WORTH SAYING
BECAUSE 0.10.0 HAD ONE AND NOTHING IN ITS PREAMBLE COULD WARN YOU.**
`app/control.py` is not in this release's diff at all, and neither are
`allocator.py`, `arbiter.py`, `arbitrage.py`, `clamp.py`, `peakguard.py`,
`maintenance.py` or `watchdog.py`. The runtime files that move are
`app/freshness.py` and `app/main.py` (SAFETY-56's three sentences), and
`app/pv.py` - new - with `app/main.py`, `app/mqtt.py`, `config.yaml` and
`translations/` (TEL-11). Contrast [[SAFETY-48]] in `## 0.10.0`, which altered
what the inverter is asked to do while touching no option, no default and no
validator rule, so that nothing a config check could see would mention it. This
release has nothing of that shape in it.
⚠️ **IF YOU ARE CROSSING FROM A VERSION OLDER THAN 0.10.0, THIS SECTION IS
STILL NOT THE ONE THAT CAN REFUSE YOU - `## 0.10.0` BELOW IS.** `ha addons
update` does not walk the versions; it installs 0.11.0 in one step, so every
validator rule added in 0.8.0, 0.9.0 and 0.10.0 arrives at the same moment as
this section's nothing. Two of them can refuse a config that nobody has edited:
> [[SAFETY-39]]'s **rule 10**, added in 0.8.0, against 0.7.0's own shipped
> default `slew_w: 1000` - the ceiling is 2/18 of the site rail, which is
> **555.6 W** on a 5000 W rail.
>
> [[TARIFF-07]]'s three withdrawn `price_provider` ids - **`engie_dynamic`,
> `totalenergies_dynamic` and `eneco_eddy`** - each of which is **still refused
> by name at startup on 0.11.0**, with the same message and for the same
> measured reasons: a 404 from a gateway with no route, a TLS handshake against
> a hostname the certificate does not cover, and a 404 with an empty body.
⚠️ **NEITHER OF THOSE IS NEW IN 0.11.0, AND NEITHER IS NEWS TO A SITE ALREADY ON
0.10.0 OR 0.10.1 - IT HAS ALREADY MET THEM.** They are restated here only
because this is now the newest section, and a reader who opens the newest section
and stops would otherwise never meet the one class of thing that can stop the
add-on starting. **The full account of both is in `## 0.10.0` below**: what to
set instead of each withdrawn id, which tariff a site left on one of them has
really been running, why the refusal *is* the migration, and why all three ids
stay in `config.yaml`'s `price_provider` enum even though `PROVIDERS` is down to
three. **That is the section that withdrew them, it is where the evidence is,
and it is not superseded by this one.** ⚠️ The reference install is on
`price_provider: off` and at `slew_w: 400`, so neither applies to it.
`tools/predeploy_check.py` checks both against your live options blob before you
press *Update*, and on this tree it reports a real version change rather than
0.10.1's no-op.
Contents of this release, in merge order since 0.10.1 (`b0b24e5`):
| | |
|---|---|
| `c9aaf7f` | SAFETY-56 - the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can **⚠️ TEXT ONLY, BEHAVIOUR BYTE-IDENTICAL** |
| `94da37f` | TEL-11 - PV production stops being invisible, and stays out of the control law **⚠️ NEW OPTIONAL OPTION, UNSET ON EVERY EXISTING INSTALL** |
⚠️ **TWO MORE MERGES LANDED IN THIS WINDOW AND ARE DELIBERATELY NOT IN THE TABLE
ABOVE: [[CI-9]]'S FOLLOW-UP (`9f6b9f1`) AND [[SEC-2]] (`239e120`). THE RULE IS
[[PKG-15]]'S - AUDIENCE, NOT IMPORTANCE - AND BOTH FAIL IT THE SAME WAY.** This
file is the **add-on's** release note: the text the Supervisor renders beside the
version number, read by somebody deciding whether to press *Update* on a battery
that is currently regulating. A row here has to be something that reader can act
on.
* **CI-9's follow-up changes one file, `.gitea/workflows/checks.yml`**, exactly
as CI-9 itself did, and it is comment-only within that file. It is not under
`goodwe_controller/`, it is not in `predeploy_check.py`'s `RUNTIME` tuple, it
is not in the built image, and **there is no version of this add-on on which an
operator can observe it.** `## 0.10.0` excluded CI-9 on exactly that reasoning;
excluding the follow-up on any other reasoning would make the rule mean
nothing.
* **SEC-2 adds `docs/RELEASE.md` and two lines to `README.md`, and this one is
the closer call, so here is the whole of it.** SEC-2 is by some distance the
more consequential of the two: it is the ticket that made `master` refuse a
direct push, and it is *why this release reaches you as a pull request into
`release/1.0` and then into `master`, rather than as a push straight to the
branch the Supervisor clones* - which is how 0.10.1 got there. It is also
**purely a procedure for whoever cuts a release**; both files sit outside
`goodwe_controller/`, neither is in the image, and no install can tell whether
that document exists or what it says. An operator reading it learns nothing
about 0.11.0 that helps them decide whether to take it. So it is excluded, and
it is excluded under the same sentence as CI-9: ⚠️ **importance to this
repository is not the test. Observability on an installed add-on is.**
⚠️ **AND BOTH ARE WRITTEN DOWN, JUST NOT HERE.** CI-9's follow-up is PR #102 plus
the comment block at the top of `.gitea/workflows/checks.yml`, which carries the
measurements in full; SEC-2 is PR #108 plus `docs/RELEASE.md` itself, which is
now the canonical account of the release path and is the procedure this release
followed. ⚠️ **If a later CI or packaging ticket changes what the shipped image
contains, it belongs in this table.** Neither of these does.
### SAFETY-56 — three messages stop blaming healthy hardware
⚠️ **NOTHING THE ADD-ON DOES CHANGES. THREE THINGS IT SAYS DO.** Same
conjunction, same limits, same `MISSING`, same 0 W command, same NOT READY row,
same [[SAFETY-57]] release at 32 s. `tools/safety56_behaviour_trace.py` is what
says so rather than a commit message: it hashes a document with no sentence
anywhere in it, built from **2390 one-second reads replayed out of the committed
2026-09-21 bus capture**, a **66-cell command × register grid stepped 120 times
each**, and **six driven controller worlds**. That document is
`6030175ed2ab9a41…` on `release/1.0` and on this tree, byte for byte, while the
sentences differ. ⚠️ **And the tool REFUSES to report "behaviour unchanged" when
the sentence halves agree**, so an identical pair is a result rather than one
tree compared with itself.
**THE DEFECT, AND IT IS NOT A TYPO.** [[SAFETY-37]]'s freshness gate fires when a
battery-power register holds one value while the standing command moves. That
conjunction is satisfied by **two disjoint worlds**:
1. the register has stopped reporting reality - which is what the gate was built
to catch; or
2. **reality is not moving**, because the source cannot comply with the command.
A BMS refusing a discharge at its floor holds the pack still under any
setpoint, and a register reporting that honestly publishes the same unchanged
number a dead one does.
**Nothing the gate is handed separates them, and three sentences asserted the
first.** ⚠️ **On the one episode this repository has measured, it was the
second.** On 2026-09-21 the pack read **11 %** for the whole 850 s hold, **every
command inside that hold was a discharge**, and the register **answered the first
CHARGE command three seconds later**. All three numbers are read off the
committed capture by `test_freshness.py` part 11a rather than typed there. The
register was healthy and truthful throughout, and the add-on said it had failed.
**THE THREE SURFACES, so you can recognise what moved:**
| where you read it | what 0.10.1 said | what 0.11.0 says |
|---|---|---|
| the **action log** and the **status page** — both quote `freshness.py`'s `STALE_READING:` line verbatim, through `_read_unit()` and `stale_note()` | `… the reading is not following, so it is reported as MISSING` | `… TWO THINGS LOOK LIKE THIS AND THIS GATE CANNOT TELL THEM APART: the register may have stopped reporting reality, or the source may be unable to comply with the command …` |
| the **add-on log**, at ERROR, from `main.py` | `SAFETY-37: <unit> battery-power register is not following its own command` | `SAFETY-37: <unit> battery-power reading did not move under a command that did, WHICH IS NOT BY ITSELF A VERDICT ON THE REGISTER` |
| the **readiness row** on the diagnostics page | `battery power: <entity> is missing or not numeric` | `battery power: no usable value this cycle from <entity> - and this row cannot tell which of two things that is … Confirm the entity in Developer Tools before replacing it` |
⚠️ **THE THIRD ROW IS THE ONE THAT COST AN OPERATOR AN EVENING, AND IT IS THE
WORST THING A DIAGNOSTIC CAN DO: IT ASSERTED A FALSE FACT ABOUT A NAMED
ENTITY.** It read *"is missing or not numeric"* for **any** `None`, and one of
the ways that value becomes `None` is the freshness gate withholding a reading
that is present, numeric and updating - `Freshness.reading()` returns `None`
there **by design**. So the operator opened Developer Tools on the entity the row
named, found it working, and had every reason to conclude the diagnostics were
broken. **It is fixed by saying less, not by looking harder:** the row does not
branch on the gate's state, because the gate already has a surface of its own -
`stale_note()` rides `liveness_notes()` a few rows below with the whole
`STALE_READING` sentence in it - so your discriminator is *"is that row there?"*,
and this row's only job is to stop pre-empting the answer.
⚠️ **WHAT IT DOES NOT GIVE YOU IS WHICH OF THE TWO IT WAS.** Naming which would
need the SoC and the pack floor, and those are deliberately not `freshness.py`'s
inputs - they are [[TEL-08]]'s and [[SAFETY-32]]'s numbers, on their own rows.
**SoC is STATED in these sentences and never WIRED into them**: part 11b drives
the same two worlds at 50 % and at 11 % and the sentence does not move one byte.
What changed is that the add-on now tells you it cannot tell, instead of guessing
and blaming your hardware. **The reading rule is unchanged from
`### SAFETY-57` below**: if the stale/withdrawn pair keeps repeating, the unit
really does want looking at; if it happens once at a low SoC and stops, the pack
was empty and the site has resumed.
⚠️ **AND THE THREE WORDINGS SHARE NO HELPER, ON PURPOSE.** Two of them are log
lines about a **behaviour** and the third is a banner about an **entity**; they
answer different questions ("what did the register do" against "can I trust this
entity"), and one helper serving both would have to drop whichever half the other
caller does not need - and the half it dropped would be the operator's next step.
**Full account: `DECISIONS/SAFETY-56-what-the-gate-cannot-tell-apart.md`.**
### TEL-11 — `pv_entity`: PV production gets recorded, and stays out of the control law
⚠️ **UNSET, THIS IS NOT A CHANGE AT ALL - AND THAT IS MEASURED RATHER THAN
ASSERTED.** `pv_entity` ships empty, which is what **every** install that
upgrades into this version lands on. Empty means the add-on **reads no entity,
announces no entity, publishes no topic, shows no status row and adds no page
row.** `tools/tel11_pv_trace.py` drives five grid behaviours × eight
PV-sensor behaviours through 24 cycles of the **shipped** `Controller`, on
`release/1.0` and on this tree, and hashes two separate documents - one of
**control** decisions and one of **telemetry**:
| document | tree | `pv_entity` | sha256 |
|---|---|---|---|
| control | `release/1.0` | unset | `846a10a5b89e3210…` |
| control | TEL-11 | unset | `846a10a5b89e3210…` |
| control | TEL-11 | **set** | `846a10a5b89e3210…` |
| telemetry | `release/1.0` | unset | `a443a6ceaffe072b…` |
| telemetry | TEL-11 | unset | `a443a6ceaffe072b…` |
| telemetry | TEL-11 | **set** | `4e6d1cb289a95722…` |
**Read the two `unset` rows first.** They are byte-identical in **both**
documents, which is a stronger claim than "the control path is untouched": an
install that does not set the option sees no change of any kind, announcements
and status rows included. **Then read the `set` row of the control document** -
identical again, while telemetry moves. ⚠️ The tool **REFUSES** unless the two
trees' `app/` fingerprints differ and unless exactly one side reacts to the
option, so a matching pair cannot be two runs of the same tree.
⚠️ **IT IS NOT A CONTROL INPUT, AND IT DOES NOT CHANGE WHAT THE LOOP DOES.** It
is instrumentation and nothing else. It is not read by the control law, the
allocator, the arbiter, the peak guard, the maintenance cycle or any watchdog; it
is **not part of `inputs_ok`**, so a PV integration that breaks cannot stop your
battery being regulated; and its status row is a **caution** (`warn`), never a
`bad` row, so a telemetry channel can never put a battery site into NOT READY.
`test_pv.py` part 6 drives 40 cycles of the real `cycle()` and asserts the
commands are bit-identical across unset / no reading / 0 W / 8 kW, with a
**computed** census of all 33 modules under `app/` showing the material is
mentioned in exactly three of them: `pv.py`, `main.py`, `mqtt.py`. Wiring
production into the control law would be a behaviour change on a system driving a
real battery - and it would destroy the measurement, because the loop would then
be reacting to the thing being measured.
**WHAT YOU GET IF YOU DO SET IT.** One new MQTT-discovery sensor,
`sensor.goodwe_pv_power`, `device_class: power` and ⚠️ **`state_class:
measurement`** - which is the point of the row, because that is what puts the
number into the recorder's long-term statistics, and a week of statistics is what
the attribution needs. **Positive is producing.** The unit is **read off your
entity's own `unit_of_measurement`** - `mW`, `W`, `kW`, `MW`, `GW`, `TW`, Home
Assistant's own power units, every factor an exact power of ten. A sensor with
**no** unit, or with a unit that is not power, is **refused by name, and the
status page says which entity and which unit.** There is deliberately no
magnitude heuristic: nothing can separate 30 W of dusk from 30 kW of noon, and a
silent factor of 1000 in the one channel that exists to be believed a week later
is worse than a refusal you can read.
⚠️ **ABSENCE IS PUBLISHED AS `unknown`, NOT AS 0 AND NOT SKIPPED. THIS IS THE
DESIGN DECISION WORTH YOUR ATTENTION.**
| what happened | `sensor.goodwe_pv_power` | the status page |
|---|---|---|
| `pv_entity` not set | the entity does not exist | no row at all |
| set, sensor answered 4100 W | `4100.0` | `PV 4 100 W` |
| set, sensor answered 0 W | `0.0` | `PV 0 W` |
| set, sensor unavailable / missing / bad unit | `unknown` | `PV —`, plus a caution naming the reason |
The last two rows are why the key is shaped this way. `publish()` normally
**drops** a `None`, which is right for `circulation` - there the last figure
standing beats a zero that reads as health - and **exactly wrong here**: a
dropped row leaves Home Assistant holding the last number it was told, for ever,
and the recorder then draws a **flat line through the outage**, which is
indistinguishable from a measurement. Anyone reading that week back would
conclude the sun was not shining, ⚠️ **which is precisely the conclusion this
channel exists to TEST rather than to manufacture.** So the absence is published,
using Home Assistant's own no-value payload (`mqtt/const.py` declares
`PAYLOAD_NONE = "None"` and `mqtt/sensor.py` tests it *before* the numeric
branch), the entity's state becomes **`unknown`**, and the recorder stores a
**gap**. A failed read also **clears** the previous good one: the value never
outlives its own sensor.
⚠️ **WHY IT IS A HOME ASSISTANT ENTITY AND NOT A REGISTER.** The RS485 bus this
add-on speaks carries the **battery** inverter it drives. On nearly every site the
PV inverter is a different box from a different vendor on its own connection,
reporting into Home Assistant through its own integration - so this takes
whatever `sensor.*` your PV integration already provides, **any brand Home
Assistant can read**, and nothing anywhere assumes it is on the bus.
**THERE IS NO `pv_invert`, AND THAT IS NOT AN OVERSIGHT.** `meter_invert` and
`batt_invert` exist because those two quantities are **bipolar and are read by
the control path**, where a reversed sensor hands the site a plausible number it
acts on. Production is unipolar and is read by **nothing**, so a reversed sensor
cannot mislead a decision, and it announces itself as **−4 kW at noon** in the
very history this key exists to create. A flag would only let an installer hide
it. There is no negative-value alarm either: a PV inverter's own standby draw
makes a small negative reading at night ordinary, so any threshold would be a
number nobody has measured.
⚠️ **WHAT THIS RELEASE DOES NOT DO, AND IT IS THE REASON THE CARD EXISTS.** It
does not answer [[OPT-10]]'s question. That card measured this site over sixteen
days: the pack reached 90 % SoC on **two** of them, and **20.5 kWh of surplus
left the site while the pack still had room** - 12.6 kWh of it with the battery
not charging at all - and it could not say **why**, because PV production was
recorded **nowhere**. Three causes need three different fixes (no irradiance:
nothing to fix; a charge-power limit; the optimiser declining to charge, which is
the only software defect), and guessing between them is how an optimiser gets
tuned to solve a cloud problem. **0.11.0 adds the channel. The attribution needs
a week of history through it, and is OPT-10's own card.** So the reason to set
`pv_entity` on the day you take this update is that the clock on that week starts
when you do.
**Full account: `DECISIONS/TEL-11-pv-production.md`, with the operator's version
under "PV production" in `DOCS.md`.**
## 0.10.1
**A PATCH RELEASE, AND ONE TICKET IS THE WHOLE OF IT: [[SAFETY-57]].** The last
place moves because this is a bug fix to a version that has shipped and is
regulating a battery, not a change to what the add-on offers. **The option
surface does not move at all** - no key added, none removed, no default changed,
no enum widened, no rule added to `validate.py` - so ⚠️ **a stored options blob
that starts the add-on on 0.10.0 starts it on 0.10.1**, and there is no
`SystemExit(78)` to plan around on this hop. If you are on 0.10.0, the only
question worth your time is whether you have been hit by what it fixes, and
`### SAFETY-57` below is written to answer exactly that.
⚠️ **WHY THIS IS A NEW NUMBER RATHER THAN A FOLD INTO 0.10.0, WHICH IS THE
REASON THE TICKET EXISTS.** The Supervisor decides that an update is available
by comparing `config.yaml`'s version string with the one the box reports.
0.10.0 is installed and running, so a fix delivered inside `## 0.10.0` would
leave every box reporting `0.10.0` believing it was already current - the
PKG-06/PKG-07 no-op, in the form where the tree it hides is a safety fix.
0.10.0's own section argued it could still be folded into; ⚠️ **that argument
was explicitly conditional on 0.10.0 never having been installed, and the
condition has fired** - see the closing note at the end of `## 0.10.0` below.
⚠️ **IF YOU ARE CROSSING FROM A VERSION OLDER THAN 0.10.0, THIS SECTION IS
NOT THE ONE THAT CAN REFUSE YOU - `## 0.10.0` BELOW IS.** `ha addons update`
does not walk the versions; it installs 0.10.1 in one step, so every validator
rule added in 0.8.0, 0.9.0 and 0.10.0 arrives at the same moment as this
section's nothing. Two of them can refuse a config that nobody has edited:
[[SAFETY-39]]'s **rule 10** against 0.7.0's own shipped default `slew_w: 1000`,
and [[TARIFF-07]]'s three withdrawn `price_provider` ids - **`engie_dynamic`,
`totalenergies_dynamic` and `eneco_eddy`** - each of which is still refused by
name at startup on this version, with the same message. Both are written out in
full under `## 0.10.0`, and `tools/predeploy_check.py` checks both against your
live options before you press *Update*.
Contents of this release, in merge order since 0.10.0 (`cb3f686`):
| | |
|---|---|
| `b9f7bd0` | SAFETY-57 - the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested **⚠️ MEASURED ON THE LIVE SITE** |
⚠️ **AND THAT IS THE WHOLE TABLE, WHICH IS THE POINT OF A PATCH NUMBER.**
[[TEL-10]] and [[SAFETY-48]] also merged after `cb3f686`, but [[PKG-15]] folded
both into `## 0.10.0` **before 0.10.0 was installed**, so they shipped under
that number and are recorded there rather than here. [[CI-9]] and [[PKG-15]]
itself touch `.gitea/workflows/checks.yml` and this file only - nothing an
operator can observe on an installed add-on - and are excluded for the reason
`## 0.10.0` already gives. ⚠️ **Two defects that the reference install's own
field history found are NOT in this release**: [[SAFETY-56]] (the stale-reading
message says *"is not following its own command"* when the true cause is an
empty pack, and the NOT READY row that goes with it) and [[SAFETY-58]] (a trip
on the first read after a rest). Both were open when this section was cut, both
are wording or bound changes rather than deadlocks, and neither was allowed to
delay this one. ⚠️ **[[SAFETY-56]] HAS SINCE BEEN FIXED AND IS IN `## 0.11.0`
ABOVE.** The wording quoted in this paragraph is what **0.10.1 actually ships**
and is left standing for that reason - if the box in front of you reports
`0.10.1`, that is the sentence it will print at you. It is not what 0.11.0 says.
[[SAFETY-58]] is still open.
### SAFETY-57 — the stale-reading verdict gets an exit
⚠️ **WHETHER YOU WANT THIS UPDATE, AND HOW TO TELL.** On 0.10.0 the add-on
can enter a state it cannot leave: the command is parked at **0 W**, the
battery-power reading is gated to **MISSING**, and the only condition that
would clear the gate is one that a parked command cannot produce. **It is a
deadlock, not a slow recovery.** On the reference site on 2026-09-21 it held
for about **thirteen minutes while the house exported 2.4 kW**, and it ended
only because a human restarted the add-on.
**Recognising it costs one look at the status page and one at the log:**
| | |
|---|---|
| the setpoint | sits at **exactly 0 W** and does not move, while the house is plainly importing or exporting |
| the battery-power sensor | is **flat at one number** for the whole of it - on the live episode, −3 W for 850 s |
| the action log | carries a `STALE batt` line and **no** clearing line after it |
**What ends it on 0.10.0 is a restart of the add-on**, and a restart is enough -
nothing is latched to disk and the pack is not harmed. ⚠️ **But nothing ends it
by itself**, and the replay below says the wait can run to hours. On 0.10.1 the
state releases itself after a bounded **32 s** and the register is re-graded
from scratch.
⚠️ **IT IS NOT AN EMERGENCY AND IT IS NOT COSMETIC.** The pack is not at
risk in this state - 0 W is the safe command, and it is the command §11.1 rule 1
asks for on a missing input. What is lost is the site's own control while it
lasts: the battery neither charges nor discharges, so a solar export goes to the
grid and an evening load comes off it.
⚠️ **WHAT IT FIXES, ON THE OWNER'S OWN BATTERY.** [[SAFETY-37]]'s freshness gate
reports a battery-power register as MISSING when it stops following its own
command, and a missing input is `command 0 W and keep commanding` (§11.1
rule 1). The gate's only exit was *"an arrival carrying a different number"* —
**and at 0 W nothing is asking the register to be anywhere.** The state had no
exit reachable from inside it, and the log line said the opposite.
Measured off the RS-485 bus, 2026-09-21, and committed as
`scenarios/safety57-2026-09-21/`:
| | |
|---|---|
| 10:51:24 | 0x0518 reaches **−3 W**. The pack is at 11 %, the loop has just reversed out of a charge, and the BMS refuses the discharge. The register is **healthy and truthful**. |
| 10:51:29 | the command reaches **+1060 W**, 800 W of travel |
| 10:52:00 | the gate arms. `Inverter.batt` becomes `None` |
| 10:52:21 | **the site commands 0 W — on the wire, in the capture** |
| … | the register does not change value for **850 s**. The setpoint does not change value for **790 s**. The house exports 2.4 kW throughout |
| ~11:04 | **a human restarts the add-on.** That is what ends it |
It had been escaping by luck - and ⚠️ **on this episode it did not escape at
all.** `0x0518` answered the same −3 W on 90 consecutive responses and never
once carried a different number between 10:51:24 and 11:05:35. The register did
not move.
⚠️ **AND WHY IT USUALLY DOES MOVE IS NOT SOMETHING THIS REPOSITORY HAS
MEASURED.** An earlier draft of this entry named a BMS keep-alive pulse as the
thing that twitches the register, stated as fact; **no committed capture
identifies such a pulse**, distinguishes one from the register simply following
a command, or sizes it. The honest statement is that the register changes value
for reasons that belong to the battery's firmware. What IS measured is how long
it goes without changing: replaying the committed 16-day loop capture through
the shipped conjunction finds **93 trips** whose wait has a **median of 143 s**
and a worst case of **5 h 57 m**, with **16 of the 93** at or beyond this
episode's **790 s**. That figure is stronger than the firmware story it
replaces, and it needs no firmware story at all.
**The rule, and it is [[SAFETY-13]]'s shape one module over** — which latches
get an exit, not how long the block lasts:
> the verdict is withdrawn when the obligation that produced it has been gone
> for `RELEASE_S`, and the register is then re-graded from scratch.
`RELEASE_S` is **17.0 s**, the obligation window already derived in
`freshness.py` — 6.0 s of plant, one 10 s ESPHome publish, one 1 s add-on read.
It is the **floor** of its band rather than a preference: below it the release
pre-empts the cheaper exit (the register answering by itself), and being wrong
*long* is the failure being fixed. **The whole parked interval is now
`stale_input_s` + `RELEASE_S` = 32 s**, bounded by two shipped numbers and by
nothing the battery does. On the live episode: telemetry back at **10:52:39
instead of 11:05:35**, with **0x0518 still answering the same −3 W**.
⚠️ **WHAT IT COSTS, AND IT IS NOT SMALL.** A register that is dead for good is
re-graded for ever. Driven over 1201 reads at the shipped defaults: the held
number reaches a consumer on **630 reads (52.5 %)** against 35 (2.9 %) before.
That is payable only because **one re-grading window is 35 s and the two
consumers hold for 75 s and 85 s** — neither can reach a verdict inside one,
and the re-trip that ends each window hands them a `None`, which *clears* their
windows. **No detection SAFETY-37 had is given back**: a permanent `None`
clears those same windows for ever too. What the site gets back is its
meter-derived control, and the command was never derived from `batt`.
⚠️ **THAT 35 s HOLDS WHILE THE OBLIGATION COMES BACK, AND ONLY THEN - IT IS NOT
A UNIVERSAL BOUND, AND THE FIXTURE THAT GRADES IT CANNOT SHOW OTHERWISE.** A
window closes when the gate re-arms, and the gate needs a command that is
*moving* to re-arm against. If the release lands where the site then regulates
below `MOVE_W`, nothing re-arms, the window never closes, and the held number
reaches a consumer for an unbounded time - where before this card a `None` did.
The driver behind the 35 < 75 < 85 inequality puts a 1300 W obligation back on
every release, so it is the one shape that cannot produce that case. On the
shipped roster of **one** inverter neither consumer can reach it anyway - the
per-unit sign watchdog is compared against the **meter** at `n_units <= 1`, and
`circulating_w()` is identically `0.0` there - so this is **a stated gap rather
than a covered one**, and it needs a second inverter to bite.
⚠️ **WHAT YOU WILL SEE.** A new `STALE WITHDRAWN <unit>` line in the action log
beside the existing `STALE <unit>` one, and a log warning that says in its own
words that **nothing has been learned about the register**. If the pair repeats
every ~70 s, the register really is not following and the unit needs looking at;
if it happens once and stops, the pack was simply empty and the site has
resumed. The stale line's escape clause was also corrected — it used to promise
a clearance the state could not produce. ⚠️ Its **diagnosis** half still says
*"is not following its own command"*, which is wrong in a different way when the
pack is merely empty; that wording is [[SAFETY-56]]'s and is deliberately
untouched here.
⚠️ **AND THAT IS NOW A STATEMENT ABOUT 0.10.1 ONLY — [[SAFETY-56]] REWROTE THE
DIAGNOSIS HALF, AND `## 0.11.0` ABOVE CARRIES THE NEW WORDING.** The quotation
above is left exactly as it stands because it is what the 0.10.1 image prints,
and a reader on 0.10.1 needs to recognise it. The same applies to the reading
rule in the paragraph above: on 0.11.0 the add-on no longer asserts that
*"the register really is not following"* — it names both explanations and says
it cannot tell them apart — so *"the pair repeats → look at the unit, it happens
once and stops → the pack was empty"* stops being a correction of the message
and becomes the message's own advice. Nothing about **what** the gate does moved
in either card.
## 0.10.0
⚠️ **A CONFIG THAT IS LEGAL ON 0.9.0 IS REFUSED ON 0.10.0, AND THAT - NOT THE
NUMBER OF TICKETS - IS WHY THIS IS A MINOR BUMP RATHER THAN A PATCH.** Same
shape as 0.8.0's `slew_w` rule and the same test: is there a stored options
blob the previous version started on and this one will not? There is. A refusal
is `SystemExit(78)` (`EX_CONFIG`) - the add-on does not start, ⚠️ **and the
ingress panel goes with it**, because the add-on serving it is not running, so
recovery means the Supervisor UI.
Measured on the reference install's own exported blob (70 keys), merged over
this version's 75 defaults the way the Supervisor merges it, inside the CI
image. The three below are what a reader who checks only one thing should
check.
* ⚠️ **[[TARIFF-07]] - THREE `price_provider` IDS ARE RETIRED, AND A SITE SET
TO ONE OF THEM IS REFUSED BY NAME AT STARTUP.** `engie_dynamic`,
`totalenergies_dynamic` and `eneco_eddy` are gone from `PROVIDERS`. Each was
accepted, silently, at every startup on 0.9.0 and earlier; on 0.10.0 each is
a refusal that names the id, the endpoint, what that endpoint actually
answers - a 404 from a gateway with no route, a TLS handshake against a
hostname the certificate does not cover, a 404 with an empty body - which
tariff the site has really been running since the id was entered, and what to
set instead. **The refusal IS the migration.** Every fetch any of the three
ever made ended in `SourceUnavailable`, and §11.4 turns that into a SILENT
fall back to the static profile, so there is no working behaviour to preserve
and nothing on the status page ever differed from a provider that simply
never found a cheap hour. ⚠️ **All three ids stay in `config.yaml`'s
`price_provider` enum on purpose**: drop one and the Supervisor rejects the
options file *before the add-on runs*, the operator gets an opaque `expected
one of ...`, and `validate.py`'s message is never seen - on exactly the sites
that need it. `PROVIDERS` is three; the enum is seven.
⚠️ **The reference install is on `price_provider: off` and is unaffected.**
* **[[TARIFF-18]] - `price_taxes_eur_kwh` moves from `0.06` to `0.11736`, and
the non-obvious half is the refusal that deliberately does NOT happen.** A
site that *stored* `0.06` is unaffected in both directions. It keeps `0.06`,
because `App.options` is `deepmerge(config.yaml defaults, stored options)`
and a moved default reaches only keys the blob does not carry - so the new
figure arrives at a **fresh** install, and at an existing one only when its
options are re-saved. ⚠️ **AND IT DOES NOT BECOME A STARTUP REFUSAL EITHER,
WHICH TOOK A MECHANISM.** [[TARIFF-17]] made a `price_taxes_profile` period
table beside a **non-default** `price_taxes_eur_kwh` a refusal, comparing
against the shipped default precisely because the Supervisor writes the key
whether the operator typed it or not. Moving the default turns every stored
`0.06` into "non-default" **with nobody editing anything**, so a working
Walloon or Brussels site with a period table would have stopped starting on
this upgrade, over an inert number the table overrides anyway.
`price.py` carries `SUPERSEDED_TAXES_DEFAULTS_EUR_KWH = (0.06,)` and
`validate.py` reads a superseded default as *untouched*. **The rung is not
weakened**: the same table beside a figure that is neither the shipped nor a
superseded default - ORES's `0.1198` - is still refused, by name, and the
refusal now says which two figures it will accept.
* **[[SAFETY-10]] - a new `shadow_mode` option, shipped `auto`, and BOTH halves
of what that does matter.** ⚠️ **AN EXISTING INSTALL THAT IS CONTROLLING DOES
NOT CHANGE BY ONE WATT.** `auto` is not a constant the Supervisor merges; it
is a value the add-on **resolves**, and it resolves to `not control_started`
- `shadow.engaged()` reads `Controller.auto`, the persisted start/stop state.
An install with `auto_start: true`, or whose operator has pressed *Start /
stop control*, is started, so `auto` resolves to live. An install that is
**stopped** keeps its actuator at 0 W exactly as before, from the same writer
on the same heartbeat; what changes is what the status page says and that the
decision path now runs and is recorded. ⚠️ **A FRESH INSTALL COMES UP
OBSERVING**: it ships `auto_start: false`, has no stored `auto` key, and
therefore runs its whole decision path in shadow before it is ever allowed to
command anything. That is the "default-on" the card asked for, delivered
where it is safe and withheld where it is not - there is no mechanism in the
add-on options system by which one key can default differently for a new
install and an existing one, so a literal `shadow_mode: true` default would
have stopped the battery at the reference site on the next update.
**Measured cross-revision** - the same stimulus through the shipped
`Controller.cycle()` on `8f82dd4` (the merge before SAFETY-10) and on
`e6da478` (SAFETY-10 itself), start button ON: the write streams are
**byte-identical**, 13 / 13 / 25 writes on a 6000 W import, a 4000 W export
and a 300 W trickle, same values in the same order. An install that is
**stopped** is byte-identical across the same pair too, at one 0 W write.
⚠️ The positive control is what makes that readable: the same driver with
`shadow_mode: on` and the button ON gets 13 writes up to 5000 W on the older
tree and **one 0 W write** on the newer, so the driver does reach shadow mode
and an identical pair is a result rather than a silence. The shadow case is
also graded in `test_clamp.py` part 8 on what reached `set_number()`, against
a precondition run that puts 30 non-zero writes on the wire. ⚠️ An
unrecognised `shadow_mode` fails toward inaction
**and** is refused by name (rule 11), so the reinterpretation is never
silent; no blob written before 0.10.0 can carry one.
⚠️ **AND 0.10.0 CHANGES THE CONTROL LAW ITSELF, WHICH NOTHING ABOVE AND NO
CONFIG CHECK WILL TELL YOU ABOUT.** [[SAFETY-48]] bounds how far the
integrator may run ahead of the command on the cycles where the slew limit is
what stopped the command moving. It adds no option, moves no default and
refuses no blob, so every check in this preamble passes it in silence - and it
is the one change here that alters what the inverter is ASKED TO DO on a tree
that is otherwise configured identically. ⚠️ **What it is measured to buy is
less EXPORT. It is NOT a lower capacity-tariff peak, and your billed quarter
should not be expected to improve.** The whole account, including what it costs
and what it does not establish, is `### SAFETY-48` below.
⚠️ **AND IF YOU ARE UPGRADING FROM 0.7.0 - WHICH THE REFERENCE INSTALL WAS
WHEN THIS WAS WRITTEN, AND HAS NOT BEEN SINCE 2026-09-20 - THE REFUSAL THAT CAN
STOP YOU IS IN 0.8.0'S SECTION, NOT IN THIS ONE.** `ha
addons update` does not walk the versions; it installs 0.10.0 in one step, so
**every validator rule added in 0.8.0 and 0.9.0 lands at the same moment as
0.10.0's own**, and a config that has not been looked at since 0.7.0 meets all
of them at once. Of those, exactly one can refuse a config nobody has edited:
> [[SAFETY-39]]'s **rule 10**, added in 0.8.0, refuses an explicit `slew_w`
> above `SLEW_RAIL_FRAC x` the site rail, where `SLEW_RAIL_FRAC` is
> `LOOP_TICK_S / PLANT_SETTLE_S` = 2/18. On a 5000 W rail that ceiling is
> **555.6 W** - and ⚠️ **0.7.0's own shipped default was `slew_w: 1000`**, so
> an install that never touched the key and simply took the default does not
> start on 0.10.0 until the value is lowered.
Measured on this tree: the reference blob with `slew_w: 1000` is refused, by
name, and the same blob at its actual `slew_w: 400` is accepted. 0.9.0's own
additions cannot reach a pre-0.9.0 config at all - [[OPT-09]]'s two refusals
fire only on a roster entry that USES `capacity_kwh`, a key that did not exist
- so 0.8.0's is the whole of the crossing. **Read the live options and check
`slew_w` against the ceiling and `price_provider` against the withdrawn list
BEFORE `ha addons update`**, with `tools/predeploy_check.py`, which does both.
✅ **RUN AGAINST THIS RELEASE: CLEARED, exit 0.** ⚠️ This is the record of
a run made on 2026-09-19, when the reference box was still on 0.7.0. That
crossing has since been made; the box is on 0.10.0 and the transcript below is
history rather than the state of any install.
docker run --rm -v <repo>:/w:ro -v <dir>:/opt:ro goodwe-addon-checks:1 \
python3 /w/goodwe_controller/tools/predeploy_check.py \
--deployed-version 0.7.0 --options /opt/live-options.json
deployed on the box : 0.7.0
shipped in this tree: 0.10.0
live options pass this version's validator
CLEARED for deploy.
⚠️ **THAT RUN WAS MADE ON PKG-14'S TREE, AND [[PKG-15]] DID NOT RE-RUN IT.
HERE IS WHY IT STILL HOLDS, CHECKED RATHER THAN ASSUMED.** The two tickets
folded in below touch three files between them - `app/control.py`,
`app/main.py` and `app/mqtt.py` - and **`config.yaml` is not among them**, so
the option surface and the 75 defaults the blob is merged over are byte-for-
byte what that run measured. `app/validate.py` imports neither `main` nor
`mqtt`; from `control` it imports exactly `SLEW_RAIL_FRAC`, `LOOP_TICK_S` and
`PLANT_SETTLE_S`, and all three are **unchanged** (`2.0`, `18.0`, and their
quotient) - [[SAFETY-48]] adds `SLEW_LEAD_STEPS` and reads it inside
`compute()`, which the validator never calls. ⚠️ **And the tool's OTHER half -
the no-op check - did not run at all in that transcript**, because it is
gated on `shipped == deployed` and the box reported `0.7.0` at the time. It is
the half that refuses this fold on a box already running 0.10.0 - ⚠️ **which
the reference box now is**; see the closing note below the contents table.
**The option surface: 71 keys -> 75, `options:` and `schema:` in step.** Four
new keys, and none of them can refuse a blob written before it existed:
`price_formula`, `price_export_formula` and `price_taxes_profile` are `str?` -
**note the trailing `?`, they are OPTIONAL** - defaulting to `""`;
`shadow_mode` is `list(auto|on|off)` with no `?`, which is the shape that
becomes exit 78, and it is safe for the same reason 0.9.0's `delivery_hold_s`
was: it carries an `options:` default, so the Supervisor's merge supplies it to
every stored blob that lacks it. Nothing was removed. One default moved
(`price_taxes_eur_kwh`, above) and one enum widened (`price_provider` gains
`custom_formula`).
⚠️ **WHY 0.10.0 AND NOT 0.9.0, SINCE 0.9.0'S IMAGE NEVER REACHED THE BOX.**
The block this section closes used to say the choice depended on whether
0.9.0 had been built and pulled, and that if it had not, this work belonged
*inside* 0.9.0's section. That was written before 0.9.0's section was cut. It
has been cut since `86bdf49`, on 2026-09-07, and **28 runtime commits** have
landed behind it; folding them in would make the string `0.9.0` name two
different trees, and the Supervisor keys the built image on exactly that
string. Reusing it is the PKG-06/PKG-07 no-op in its worst form - a cached
image the Supervisor is entitled to serve while reporting success. The version
a tree has already shipped under is not available to be re-cut.
⚠️ **AND THIS SECTION IS NOT THE WHOLE OF WHAT 0.10.0 SHIPS. THREE TICKETS
WITH RUNTIME CHANGES LANDED AFTER `86bdf49` AND ARE NOT IN THE TABLE BELOW.**
Saying so is cheaper than moving them, and moving them is [[PKG-08]]'s card,
not this one:
| ticket | runtime files | where it is written down |
|---|---|---|
| [[SAFETY-43]] | `app/delivery.py`, `app/packshare.py`, `config.yaml` | the `## Unreleased` block **below `## 0.9.0`**, which is misfiled |
| [[TEST-21]] | `app/delivery.py`, `config.yaml`, `translations/` | the same block |
| [[SAFETY-44]] | `app/main.py`, `app/store.py` | ⚠️ **nowhere in this file** |
Five more landed that touch no runtime file and so cannot change what the
image does - PKG-13, UX-04, SAFETY-31, ARCH-02, INSTR-01. The count that
matters for the no-op check is `tools/predeploy_check.py`'s own: **28 runtime
commits since `86bdf49`**, of which the table below accounts for 21.
⚠️ **RE-MEASURED BY [[PKG-15]] ON 2026-09-19, AFTER FOLDING [[TEL-10]] AND
[[SAFETY-48]] INTO THIS SECTION: 32 RUNTIME COMMITS SINCE `86bdf49`, OF WHICH
THE TABLE BELOW NOW ACCOUNTS FOR 24.** Re-derived with `is_runtime()` itself
rather than by adding to the old figure. The other eight are the three misfiled
tickets in the table above - SAFETY-43 two commits, SAFETY-44 three, TEST-21
two - plus `cb3f686`, PKG-14's own bump, which edits `config.yaml` and is
therefore a runtime commit by that function's rule; it was `HEAD` when PKG-14
counted, so `last..HEAD` excluded it then and includes it now. The three
misfiled tickets are still misfiled and still [[PKG-08]]'s card; nothing below
moves them.
⚠️ **THE VERSION WAS NOT BUMPED FOR THE FOLDS ABOVE, AND THAT ARGUMENT HAS
NOW EXPIRED. THIS SECTION IS CLOSED.** As written on 2026-09-19 it ran: 0.10.0
was cut on 2026-09-16, had never been built or pulled anywhere, the reference
install was on 0.7.0 and this repository carried exactly one tag (`v0.2.1`) and
no release - so the string `0.10.0` did not yet name a tree anyone was running,
the PKG-06/PKG-07 no-op could not apply, and cutting 0.11.0 would have burned a
number on a release that never left the repository. ⚠️ **IT WAS STATED AS
CONDITIONAL ON THAT REMAINING TRUE, AND IT STOPPED BEING TRUE ON 2026-09-20 AT
ABOUT 22:18 CEST**, when 0.10.0 was installed on the reference site as a
repository add-on (slug `68285ac7_goodwe_controller`) and began regulating a
real battery. **0.10.0 has been built and pulled, and the reference install is
on 0.10.0, not on 0.7.0.**
⚠️ **AND THE FIELD HISTORY IS NOW THE STRONGEST EVIDENCE IN THIS FILE, WHICH
IS WHY THE CORRECTION IS WORTH ITS SPACE.** That install has since run a full
day-night cycle on 0.10.0 - an empty pack, a guard trip, a 2 h 47 min saturation
freeze, the [[SAFETY-57]] deadlock and a clean recovery - and **two defects came
out of it that no test in this repository had reached**: [[SAFETY-56]] and
[[SAFETY-57]]. So nothing may be folded into this section again, and
`tools/predeploy_check.py` enforces that by itself: run against a box already
reporting `0.10.0` it refuses with `THE DEPLOY WOULD BE A NO-OP` and names the
runtime commits since the bump. **SAFETY-57's fix is in `## 0.10.1` above**,
which is what a patch number is for. ⚠️ **AND SAFETY-56'S IS IN `## 0.11.0`**,
which is where it went because it landed after 0.10.1 had already been cut. Both
defects named in this paragraph are now fixed; this section, and `## 0.10.1`
below it, describe images that still contain them, and are left saying so.
Contents of this release, in merge order since 0.9.0 (`86bdf49`):
| | |
|---|---|
| `c2787da` | FCST-04 - the carry-forward fill reaches the plan, and the day it carries survives a restart |
| `5059e28` | FCST-05 - one byte stops stopping the add-on, and the write path gets the read path's standard |
| `958f5cd` | FCST-06 - "cannot persist" stops meaning "has no /data" and starts meaning what it says |
| `4257e38` | TARIFF-08 - the day-ahead feed is read in the shape it actually publishes, and the fixtures stop agreeing with the parser |
| `88c59a9` | TARIFF-09 - the day-ahead feed is asked for the horizon it was given, so tomorrow arrives firm instead of carried |
| `559f0eb` | TARIFF-10 - configuring a price provider is what fetches prices; trading stays its own switch |
| `a6e64fb` | TARIFF-12 - a supplier outage stops deleting the plan on its first failed fetch, and TARIFF_MAX_AGE_S starts governing |
| `8d09b30` | TARIFF-14 - the price a trade is decided against is the price of the interval being traded |
| `aade2c7` | TARIFF-07 - three plugins that never fetched a price are withdrawn, and a site configured on one is told so **⚠️ BACKWARD-INCOMPATIBLE** |
| `068b83f` | TARIFF-15 - `custom_formula`: your own tariff card's two coefficients, graded against the card's own printed price |
| `b4a3801` | TARIFF-13 - the capacity-tariff row's "quarter(s) banked" stops resetting to 0 at every restart, and a tied peak's quarter stops moving |
| `c518007` | TARIFF-11 - the add-on's account of the tariff plan stops flattering it, and the status page is graded as a surface |
| `7796f16` | TARIFF-17 - a price component that varies by hour has somewhere to live, so a Walloon day/night network tariff can change which hour is cheapest |
| `4dcd9b0` | TARIFF-18 - `price_taxes_eur_kwh` stops shipping at half the real Flemish figure **⚠️ CHANGED DEFAULT** |
| `478ba93` | TARIFF-16 - the injection leg stops being one number: an injection formula with its own coefficients, its own VAT and no floor under zero |
| `8f82dd4` | SAFETY-45 - a price-driven charge is SIZED by the capacity-tariff guard instead of being switched on and off by it **⚠️ CONTROL STABILITY** |
| `e6da478` | SAFETY-10 - shadow mode: the whole decision path runs and nothing reaches the inverter **⚠️ NEW OPTION, DEFAULT-ON FOR A NEW INSTALL** |
| `587495e` | SAFETY-47 - what a shadow run can show you, and the watts on its status row **⚠️ CORRECTS THREE CLAIMS SAFETY-10 SHIPPED** |
| `660d079` | TEL-10 - the loop's integrator stops being invisible: three new site sensors **⚠️ THREE NEW ENTITIES** |
| `186a044` | SAFETY-48 - the integrator's lead over the command is bounded at one slew step **⚠️ THE CONTROL LAW CHANGED** |
| _this branch_ | SAFETY-57 - the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested **⚠️ MEASURED ON THE LIVE SITE** |
⚠️ **[[CI-9]] ALSO MERGED INTO `release/1.0` IN THIS WINDOW AND IS
DELIBERATELY NOT IN THE TABLE ABOVE, NOR ANYWHERE ELSE IN THIS FILE.** It
changes exactly one file, `.gitea/workflows/checks.yml`, which is not under
`goodwe_controller/` at all: it is not in the built image, it is not in
`predeploy_check.py`'s `RUNTIME` list, and there is no version of this add-on
on which an operator can observe it. This file is the **add-on's** release note
- the text the Supervisor puts beside the version number - and the rule PKG-15
applied is that a row here has to be something the person deciding whether to
press *Update* could act on. CI-9 is not; the repository's history and PR #95
are where it is written down, and they have it in full. ⚠️ **THE RULE IS ABOUT
THE AUDIENCE, NOT ABOUT IMPORTANCE.** CI-9 repaired a merge gate that was
grading the wrong tree, which is the same class of defect this ticket exists to
clean up after - and it is still not an operator-facing change. If a future CI
ticket changes what the shipped image contains, it belongs here; this one does
not.
### SAFETY-48 — the integrator's lead over the command is bounded, and the control law changed
⚠️ **THIS CHANGES WHAT THE INVERTER IS ASKED TO DO.** It is the only entry in
0.10.0 that does so without touching an option, a default or the validator, so
nothing in this section's preamble and no run of `tools/predeploy_check.py`
will warn you about it. `app/control.py` is in the diff; `config.yaml` is not.
**The defect is a missing case, not a wrong constant.** `compute()` freezes the
integrator when the inverter is not following, and the comment beside that
block states the requirement outright — *the INTEGRATOR must stop accumulating,
not only the command*. But `frozen` was computed from one signal,
`abs(prev_w - actual_w) > saturation_w`, and **slew-limiting never entered it**.
The integrator moves `gain × error` per cycle while the command may move at
most `slew_w`, so the integrator outruns the command whenever
`|error| > slew_w / gain` — **667 W** at the live tuning, against a measured
median grid error of **1114 W** at the onset of a recorded episode. ⚠️
[[SAFETY-39]]'s retune made this **more** frequent, not less: a smaller step is
a lower threshold.
**What ships** bounds the integrator's **lead over the command** at one slew
step, inside the branch where the slew is what bound the command, and only in
the leading direction. Nothing else in the law moves: the output clamp, the
saturation freeze, the deadband and the 10 W quantisation are unchanged, and
`test_control.py`'s exhaustive `i_w=None` equivalence sweep against the
transcribed release/1.0 law still passes untouched — the cap moves `i_w`, not
`target`.
⚠️ **WHAT IT IS MEASURED TO BUY IS LESS EXPORT — AND EXPLICITLY NOT A LOWER
CAPACITY-TARIFF PEAK. DO NOT EXPECT YOUR BILLED QUARTER TO IMPROVE.** Replayed
over 256 252 recorded meter instants spanning 16.00 days of this install
(`scenarios/loop-2026-09-02_2026-09-17`, committed), same ticks, same
disturbance, same plant, same seed:
| | release/1.0 | SAFETY-48 |
|---|---:|---:|
| **export kWh** | **39.61** | **34.07** |
| wasted throughput kWh | 4.67 | 3.19 |
| battery sign reversals | 2992 | 2770 |
| median recovery s | 232 | 199 |
| unrecovered (>900 s) | 53 | 31 |
| worst \|i_w − prev_w\| W | 9200 | 800 |
That is **5.54 kWh less export — 14 % of the replayed figure**, and ⚠️ **the
direction is what is robust, not the size**: across every plant and tuning
variant swept it falls, by between ~4 % (at `gain: 0.3`) and ~16 % (at a
re-fitted gain/offset), the median variant landing near an eighth. At `gain: 0.3` and at `slew_w` set to the rail the
mean-quarter effect is a tie (−0.17 W and **+0.16 W**), because
`|error| > slew_w / gain` is rarely satisfied in those regimes and there is
little for the cap to bite on.
⚠️ **AND THE BILLED QUARTER IS NOT A CLAIM THIS RELEASE MAKES.** The A/B above
also shows the worst 15-minute average **offtake** moving 3739 → 3434 W, and
that figure exists at **one plant model**. `fit_plant()` selects a 7.5 s
inverter lag on battery-power RMS, which separates it from 2.5 s by **0.3 %**,
while the instrument's own fidelity measure — replayed export against the
**29.43 kWh this install actually exported** — prefers 2.5 s by the whole 35 %
gap. Swept properly: **at every lag ≤ 5.0 s, including the one that best
reproduces the recorded export, release/1.0's worst quarter is already 3434 W
and this change moves it by exactly zero.** The lag is not identified by this
recording, and identifying it needs a driven step response that does not exist
yet. **What this release can say about the billed quantity is that it does not
make it worse at any lag tried — not that it improves it.**
⚠️ **AND EVERY NUMBER ABOVE IS SIMULATED.** The replay is a first-order plant
model with a 375 W RMS residual; it prints its own fidelity first and it
reproduces **39.6 kWh** of export where the install exported **29.4**, i.e. it
is ~35 % pessimistic about the loop's tracking. Only the **delta** is claimed.
Nothing here drove an inverter.
**What it costs, stated rather than smoothed:**
* ⚠️ **The cap does move a saturation-frozen integrator**, because it runs
before the freeze block and is not gated on `frozen`. Of 79 160 frozen ticks
it changed `i_w` on **1095**, and on **679** of those it moved it further out
on the side it was already on — putting back magnitude the freeze had just
let fall, which is the one direction the freeze's own rule forbids. Worst
case **2424 W**. It never overrides a *same-cycle* refusal.
* **Two committed numbers moved.** [[SAFETY-13]]'s released command settles at
−800 W and −1200 W where release/1.0 settled at −1190 W and −2390 W, because
there is less wound integrator to settle onto; the property asserted is that
it stops at the frozen integrator rather than at the rail.
* ⚠️ **[[SAFETY-39]]'s claim that "the slew does not own the over-absorption"
is now FALSE — inverted**, on the independent first-order plant
`test_control.py` writes for itself: 1005/1109/1285/1330 W rising with a
slower slew becomes 729/550/424/326 falling. Two plant models that share
nothing agree on the sign. SAFETY-39's record carries a forward reference to
this one.
* **The form the card originally asked for was rejected on measurement**, and
this is the least lag-sensitive result in the work: reusing the asymmetric
freeze on a carried slew flag moves the worst quarter-hour offtake
3739 → **3935 W** at the fitted plant, and across the lag sweep it is the
worst of the three at **every lag from 2.5 s upward** — 3732 / 3711 / 3935 /
4326 W against release/1.0's 3434 / 3434 / 3739 / 3954 — with a tie at lag
0.0, and it is worse at **every top-N cut** of the quarters. It also raises
the mean quarter (+2.73 W).
`DECISIONS/SAFETY-48-bounding-the-integrator-lead.md` carries all of it,
including §8, *what this card does NOT establish*.
### TEL-10 — the loop's integrator stops being invisible
**Three new MQTT sensors, and nothing in the control path moved.**
`app/control.py` is not in this diff: `compute()`, its returned `Decision` and
every constant it reads are identical to release/1.0.
`self.i_w` has been a separate quantity from the command since [[SAFETY-04]]
and left the process **nowhere at all** — no entity, no attribute, no log line.
The investigation behind SAFETY-48 could only *reconstruct* it from the grid
trace plus a replay; the reconstruction reproduced about a third of the
engagements it was checked against and was discarded, so a control card had to
be argued from a measurement nobody could stand behind. It could not have been
made to work, either: `i_w` depends on every cycle before it, including the
ones where the arbiter overrode the loop and `main.py` re-seeded it — and that
re-seed is invisible in the grid trace.
| entity | topic | unit | what it is |
|---|---|---|---|
| `Loop integrator` | `goodwe_loop_integrator` | W | the accumulator **after** this cycle — before the output clamp, the slew limit and quantisation |
| `Loop integrator lead` | `goodwe_loop_integrator_lead` | W | that value minus **the command `compute()` was handed**, i.e. the one the previous cycle left standing |
| `Loop reason` | `goodwe_loop_reason` | — | the control law's own word for this cycle: `tracking`, `deadband`, `i-clamped`, `clamped`, `slew-limited`, `saturated-freeze`, `freeze-released` or `not-running` |
⚠️ **`Loop integrator lead` IS NOT A SUBTRACTION OF TWO PUBLISHED ROWS, WHICH
IS WHY IT IS ITS OWN ENTITY.** `Setpoint` is the **arbiter's** output after
every strategy has had its say, and it is **this** cycle's; the lead is
measured against the command `compute()` was given, which is the previous one.
On any cycle the arbiter overrode the loop the two differ — and that is exactly
the cycle on which the integrator was re-seeded, so a dashboard doing the
subtraction would get a different number precisely where it matters.
⚠️ **`Loop reason` IS NOT THE `Why` ROW AND NOT `Controller status`.** Both of
those carry the *arbiter's* sentence — `loop -> -5000 W` — which names the
winning claim and its watts and has never carried that claim's own reason.
`slew-limited`, the value [[SAFETY-48]] above is entirely about, appears in
neither. Measured on one cycle: arbiter `'loop -> -5000 W'`, loop `'i-clamped'`.
⚠️ **NOTHING EXISTING IS RENAMED, RE-TYPED OR RE-ORDERED.** The three are
**appended** after the nine messages release/1.0 already announces, and all
nine stay **byte-identical**. ⚠️ Eight of them also stay **first**, which is
what `test_mqtt.py` part 1's prefix comparison grades; the ninth,
`goodwe_ctl/availability`, is byte-identical but deliberately moves to **last**,
so a prefix comparison cannot cover it and the check on the next line pins it
in its new position instead. **They are SITE rows, not per-unit ones** — there
is one integrator, so a per-unit copy would invent N of a thing there is one of
— and they therefore appear at **every** roster length, **including a roster of
one**, where the per-unit machinery announces nothing new at all.
Both numbers carry `state_class: measurement`, so the recorder keeps long-term
statistics for them. `DOCS.md` has the operator account, including how to read
a standing lead: the cycles needed to unwind it are that lead divided by
`slew_w`.
### SAFETY-47 — what a shadow run can show you, and the watts on its status row
⚠️ **Nothing about the write path changed, and nothing needed to.** Shadow
mode still holds every inverter at 0 W through the one writer. What was wrong
is what three merged documents **said** a shadow run can show you, and a number
on the status page that could be **6.61×** what a live controller would
command.
**A shadow run cannot show you a closed-loop defect. Not partially — not at
all.** The battery is held at 0 W, so every measured input — the meter, the
billed-quarter accumulator behind it, the battery power, the state of charge —
describes a plant that did not respond, and a closed-loop defect is one whose
stimulus *is* the plant's response. That is the same property that makes shadow
mode safe, so it is not a gap to be closed later: **the closed-loop answer
comes from the closed-loop rig or from a live run.**
SAFETY-10 promised otherwise, because of a sentence that was true when it was
written and false one commit later:
> the **strategies** are unaffected — they ask for a fixed power from inputs
> that do not depend on what the battery did — so a shadow run does show you
> the trades, the peak-guard engagements and the SoC-limit behaviour.
SAFETY-45 (above) sizes the buy leg to the billed quarter's charging headroom,
and that headroom is `(900 / seconds remaining) × (ceiling − projected)` with
the projection read off the **open quarter's meter**. The strategy became
closed-loop the day that landed. Measured on the rig, one hour at `peak_cap_w`
1500 under a 1200 W house:
| | live | shadow |
|---|---|---|
| charge onsets | 28 | **1** |
| grid | −455.5 … +3200.0 W | **1200.0 W flat — the house** |
| capacity guard engaged | 410 / 720 cycles | **0 / 720** |
| state of charge | 50.000019 → 51.856789 % | **50.000000 → 50.000000 %** |
**What the documents now say.** The exemption narrows to exactly what is still
true — **which** hour a strategy picks and **why** are unaffected, because the
clock and the price series are not functions of the battery; **how hard** it
trades is not. Of the three defects shadow mode was written for, one —
TARIFF-14's wrong quarter-hour — is genuinely visible from a shadow run, and it
is graded that way: identical live and shadow on 720 of 720 charging cycles at
a binding cap.
**What you will see on the status page.** The `Shadow mode` row and the action
log now introduce the watts as what the controller would have commanded **on
this cycle** — in every state, because no number a shadow run records is a
forecast of a live run. And when a **measured** billed quarter sized those
watts, both surfaces carry:
> ⚠️ AND ITS SIZE CAME FROM THE BILLED-QUARTER METER, WHICH HAS ONLY THE HOUSE
> IN IT WHILE THE BATTERY IS HELD AT 0 W. A live run sizes the same trade
> against a meter the battery is moving, so this is an UPPER BOUND and not a
> prediction; how far under it a live run lands is a closed-loop question and a
> shadow run cannot answer it.
⚠️ **The number is caveated, not re-computed, and that was the decision.**
Re-computing it to "look right" would mean the recorded decision was no longer
the decision the shipped path reached — while the arbiter, the clamp, the
write-authorisation gate, the action log and MQTT all ran on the real one. A
shadow run's whole worth is that what it records is what the controller
actually decided. `DECISIONS/SAFETY-47-what-a-shadow-run-can-show.md` §3
records the three alternatives that were rejected and why.
⚠️ **On a site whose cap does not bind, nothing changes by one watt.** At
`peak_cap_w` 15000 against a 350 W house the recorded figure is the live one
exactly, and no caveat is a lie there either — the row still says the size came
off a meter with no battery in it, which is true and is the point.
**And SAFETY-10's own committed evidence could never have failed.** Its
comparison table ran at a cap the guard never reaches, *and* read only the
first charging sample — the one instant at which the two runs agree even at a
cap that does bind. Both had to be closed; closing either alone closes nothing.
The table is re-taken across the whole run at a binding cap, and
`test_arbitrage.py` part 3d is the CI-side grader so this class cannot recur.
14 mutations, no survivors; all 29 check files green.
### SAFETY-10 — shadow mode, and what its default does to YOUR install
A new option, `shadow_mode`, with three values and a shipped default of
`auto`. In shadow mode the add-on runs its entire decision path — strategies,
arbiter, clamps, guards — and **sends nothing to the inverter**: every inverter
is held at **0 W**, refreshed on the ordinary heartbeat by the ordinary single
writer, and the status page says plainly that the battery is not being
controlled. What it *would* have commanded, and why, is on the status page and
in the action log.
⚠️ **WHAT HAPPENS TO AN EXISTING INSTALL: NOTHING.** `auto` resolves to shadow
mode only while control is **stopped**. An install that is controlling —
`auto_start: true`, or *Start / stop control* pressed — is started, so `auto`
resolves to ordinary control and not one watt changes. An install that is
**stopped** keeps its actuator at 0 W exactly as it did before, from the same
writer on the same heartbeat; what changes for it is what the status page and
the action log **say**, and that the decision path now runs and is recorded.
⚠️ **AND THAT IS WHY IT IS NOT A BOOLEAN.** The card is titled "default-on".
Taken literally — `shadow_mode: true` in `config.yaml` — it would be the worst
change in this repository's history: the Supervisor composes an add-on's
options as *its defaults, overlaid with the stored user options*, so a new key
with a new default reaches **every existing install** on the next update,
including the one regulating a real battery at the reference site. It would
have silently stopped it, and the only symptom would have been a battery that
stopped doing anything. There is no mechanism in the add-on options system that
lets one key default differently for a new install and an existing one, so
"default-on for new" is expressed as a value the add-on **resolves** rather
than a constant the Supervisor merges.
A **new** install ships `auto_start: false`, so it comes up in shadow mode and
observes a day of decisions before it is allowed to command anything. That is
the default-on the card asked for, delivered where it is safe and withheld
where it is not.
⚠️ **A CONFIG THAT STARTS ON THE CURRENT VERSION CAN BE REFUSED ON THE NEXT
ONE.** TARIFF-07 withdraws `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. `price_provider` set to any of those three is now **refused at
startup** — `SystemExit(78)` (`EX_CONFIG`), the add-on does not start — where
it was accepted before. That is as backward-incompatible as it gets, and it is
**the point of the change** rather than a side effect of it: see the next
paragraph for why starting was the worse outcome. Same shape as 0.8.0's
`slew_w` rule, and the same instruction follows — **read the live options and
check `price_provider` against the withdrawn list BEFORE `ha addons update`.**
That check is NOT performed by this branch and cannot be.
⚠️ **THE REFUSAL IS THE MIGRATION, BECAUSE THERE WAS NOTHING TO MIGRATE.** All
three pointed at endpoints that **do not exist and never did** — verified by
hand on 2026-09-13: a 404 from a gateway with no route, a TLS hostname the
certificate does not cover, and a 404 with an empty body. Every fetch any of
them ever made failed, and §11.4 turns a failed fetch into a **silent** fall
back to the static profile. So a site configured on one of these has been
running on `static_profile` — **or on nothing at all, where none was set** —
since the day the id was entered, with nothing on its status page ever
differing from a working provider that never found a cheap hour. The refusal
names the id, the endpoint, what that endpoint actually answers, which tariff
has really been in force, and what to set instead. **Starting quietly is what
hid this; it is not an option that was on the table.**
⚠️ **THERE IS NO ALIAS AND THERE WILL NOT BE ONE.** These were retail tariffs
of the form `B × spot + A` with **per-contract** coefficients that live behind
the customer's supplier login; CREG's tariff-card pages 404 and VREG was
unreachable, so there is no public index to read them from. An alias to
`generic_dayahead` — which reads *wholesale* — would have to invent the numbers
a battery is priced against. A formula provider is the planned answer and is a
separate card. *(Annotated 2026-09-13: that card is **TARIFF-15**, below, and it
shipped on this branch as `custom_formula`. It is still not an alias — the
operator types their own coefficients; nothing is invented on their behalf.)*
### SAFETY-45 - the trade is sized by the capacity guard, not switched by it
**A price-driven charge now asks the peak guard HOW HARD it may pull, instead of
only whether it may pull at all.** On any site where `load + max_w` reaches
`peak_cap_w` - at the shipped `peak_cap_w: 3500` and `max_w: 2000`, any house
drawing over 1500 W in the cheapest quarter - arbitrage and the capacity-tariff
guard were driving each other in a sustained limit cycle. Measured on TEST-23
stage 3's closed rig at `peak_cap_w: 1500` against a 1200 W house: **28 charge
onsets in one hour, mean period 131 s, the grid swinging −456 to +3200 W**, and
every billed quarter in the three affected configurations finishing **over** the
cap it was oscillating about. §10.2: *"an EMS that oscillates is worse than no
EMS, both for hardware wear and - per §9.1 - for the peak it is trying to
avoid."*
**What was happening.** The guard computes `wanted = batt_w + excess` - the
battery discharge that would land the quarter exactly on the ceiling - and files
a claim only while that number is positive. While a trade charges at `max_w`
the number is negative for the first minute or so of every cycle, so the guard
files **nothing** and the trade is not constrained at all. `wanted` then crosses
zero, the guard engages on a floor of a few watts, and that flips
`arbitrage.guard_state()` - which cancels **the whole trade**. The
grid-following loop takes the actuator, drives the meter to zero and past it,
the projection collapses, the guard releases, and the trade comes back at
`max_w`. 115 s later, again.
**The fix, and it is a shape this add-on already had.**
`control.maintenance_charge_floor()` has always capped a MAINTENANCE charge at
"the headroom left under the site's cap", because *"a maintenance charge is the
only thing this system does that is big enough and long enough to set that
peak"*. ⚠️ That stopped being true when OPT-04 landed: a trade commands `max_w`
for a whole tariff interval, deliberately, against the meter.
`peakguard.charge_headroom_w()` publishes the same quantity off the **measured**
guard rather than off the optional `peak_forecast_entity`, and
`arbitrage.decide()` sizes the buy leg to it.
**No new arithmetic and no new constant.** The number is `wanted_w` read in the
other direction: a negative `wanted` is not "nothing to say", it is a permitted
charge of `−wanted`. `peakguard.decide()` is **unchanged** - byte-identical to
`release/1.0`, `sha256 = 200090d0835a3a55` - so 2026-08-20's anti-bang-bang rung
is exactly where it was, and `tools/replay_ac3.py` reproduces the same 190/190
guarded quarters, 110 engaged cycles and 878 Wh on this branch as on the tip.
**After, on the same rig, same command:**
| `peak_cap_w` / house | onsets per hour | grid swing | energy bought | billed quarters |
|---|---|---|---|---|
| 1500 / 1200 W | 28 → **1** | 3656 → **282 W** | 180 → **285 Wh** | 1490/1497/**1509** → **1500/1500/1500** |
| 3500 / 1800 W | 8 → **1** | 3673 → 1688 W | 1653 → 1616 Wh | **3511/3536/3559** → **3500/3500/3500** |
| 3500 / 3000 W | 32 → **1** | 3798 → **475 W** | 483 → 475 Wh | **3519/3542/3557** → **3500/3500/3500** |
| 5000 / 1200 W | 1 → 1 | *identical* | *identical* | *identical* |
One onset means the trade starts once and runs for the whole window - the
battery is now trading 100 % of the cheap hour where it traded 43 %, 92 % and
54 %. **Every billed quarter now lands on the cap and none over it.** At the
aggressive cap the site buys 58 % MORE energy, because a continuous 300 W trade
beats a 2000 W trade that is cancelled for well over half the hour; at the two
shipped-default rows it buys about 2 % less and the worst quarter drops from
59 W over the cap to zero. The last row is the negative control - `load + max_w`
never reaches the cap there, and the two runs are bit-identical. **This costs
nothing on the installs it is not about.**
⚠️ **NOT A CONFIG CHANGE.** No option is added, removed or re-defaulted, and
arbitrage remains off in the shipped configuration. A site that has not armed
`arbitrage_enabled` is unaffected in every respect.
⚠️ **WHAT IS NOT FIXED, AND IT IS NAMED RATHER THAN IMPLIED.** TEST-23 finding 1
- the export overshoot at the END of any trade, 356-938 W, about 0.37 × `max_w`
- is untouched and is a different card. A house whose load ALONE exceeds
`peak_cap_w` still has the guard engage and the trade refused outright, which is
correct, and the grid-following loop then drives to grid = 0 rather than to the
ceiling. See `DECISIONS/SAFETY-45-sizing-the-trade.md` §5, and §2 there for the
negative-`lo` design that was rejected because it creates a new `lo > hi`
contradiction against the maintenance charge shaping.
### TARIFF-16 - the injection leg stops being one number
**`price_export_formula`: what a site is PAID for export, as `factor × index +
offset` with its own coefficients, alongside the flat `export_price_eur_kwh`.**
⚠️ **THIS IS NOT A WRONG-TRADE FIX, AND SAYING SO IS PART OF SHIPPING IT.**
`arbitrage.py` does not read `export_price_eur_kwh` at all — its own comment
says so, and gives §9.3's near-zero Belgian injection price as the reason the
economically sound trade on this market is *charge cheap to displace expensive
import*. Both hours it compares are all-in **consumption** prices. So no trade
this add-on takes today is decided by an injection price, and nothing here
changes one. What it changes is what an operator is told, and what any future
export-aware strategy rests on: OPT-06 and any export logic would otherwise
inherit a scalar that cannot represent the market, and the 6% VAT asymmetry
between the two legs would be invisible in the arithmetic. `test_price.py` 17h
parses every module under `app/` and goes red the day something calls an
injection reader, so that claim is graded rather than attested.
**The market publishes a line, not a number.** Verbatim off the cards: Eneco
Zon & Wind Dynamisch `0,1 x BELPEX-H - 1,188` c€/kWh — *"Het injectietarief is
dynamisch en kan per uur wijzigen"*, identical on the January and the September
2026 cards; ENGIE Dynamic `(B x eSpot_15) - A`; Aspiravi `0,07 x Belpex - 2`.
Four properties a scalar cannot hold:
1. **Its own factor.** Eneco `0,102` on consumption against `0,100` on
injection; Aspiravi `0,07` against about `0,10` on its consumption leg. Not
the consumption `B` with a sign flip.
2. **A negative offset** — `− 1,188`, `− 2`. `price_markup_eur_kwh: float(0,1)`
cannot express a negative markup at all, so it has no home on the
consumption side either.
3. **VAT-exempt** — *"Injectietarieven zijn vrijgesteld van btw"* — while
consumption is at 6%. `vat_pct` is now **per leg**, so the six-point
asymmetry is expressible; a scalar carries no VAT field at all.
4. **It goes negative with no floor**, below `11,88 EUR/MWh` of BELPEX-H — the
midday hours a PV household exports in. You can be charged to export.
⚠️ **A NEGATIVE INJECTION PRICE IS ACCEPTED, NOT REFUSED**, and that needed a
different band rather than a lower floor. `implausible_all_in()` floors the
consumption leg at `+0.02 EUR/kWh` of energy, which is right there and fatal
here — measured, not assumed: `test_price.py` 17c puts one spec through **both**
bands and prints that the consumption band refuses `−0.03008 EUR/kWh` while the
injection band accepts it. The floor was not decoration, though: it is what
catches a card read a hundred times too small, the one unit error the card
self-check cannot see because it cancels out of a comparison between the two
sides. So the bound moves **off the price and onto the coefficients**, where it
is index-free and sign-free — a **pass-through** band (`factor` as a share of
the wholesale price; Eneco's injection leg is 1.00×, Aspiravi's 0.70×, the band
is 0.10–10×) and an **offset magnitude** bound (0.20 EUR/kWh against published
values of 0.01188 and 0.02). Two rungs that can both answer a hundredfold
error, so each is graded on its **reason**, each gets a stimulus the other
cannot reach, and they are mutated **together** (TEST-16).
⚠️ **THE CARD SELF-CHECK APPLIES WHERE THERE IS A CARD, AND WHERE THERE IS NOT
THAT IS STATED RATHER THAN WORKED AROUND.** `price_formula` can require a `card`
block because a Belgian card prints the consumption formula, the reference index
*and* the resulting price. **Eneco's injection formula is printed with no price
beside it.** Requiring a block would make the market's own published line
inexpressible; inventing the estimate would grade the coefficients against
arithmetic done with the same coefficients. So the block is **optional on this
leg and unchanged on the other**, the self-check runs at the same tolerance
wherever a printed estimate exists, and validate.py says at startup —
*"its coefficients are UNGRADED"* — when it does not, naming the two bounds that
ran instead. This is TARIFF-15 demonstrating two tariffs end to end rather than
three, one card later.
**ONE PARSER, NOT TWO.** `custom_formula.py` already shipped the units table,
the NaN rule, the closed enumerations, the unknown-key refusal, the card
comparison and `to_resolution()`'s DST handling, so `parse_export_formula()` is
that parser with its **option name as an argument** — TARIFF-17's move on
`parse_static_profile()`, exactly. Everything that differs between the two legs
is a string in one `_LEGS` table. `test_price.py` 17b pins it two ways: by
parsing every module under `app/` and asserting all 32 grammar names are defined
in exactly **one** of them, and by deriving twelve refusal sentences for the new
option from the old option's own sentence rather than transcribing them. The
three sentences that deliberately **differ** are named, with what differs, and
asserted to differ.
**NOTHING CHANGES FOR A SITE THAT DOES NOT SET IT.** The option ships `""`, and
`export_price_eur_kwh()`'s body is byte-identical — pinned on the AST, not on
the source text — with `export_price_at()` falling through to it for every index
value. `test_price.py` 17f compares seven option dicts × five index values
against the pre-TARIFF-16 expression with `==`.
`export_price_eur_kwh` and the new key are both in `FRAMEWORK_KEYS`;
`BANNED_IN_PLUGIN_CODE` is derived from that set, so `code_leaks()` refuses a
plugin that names either with nothing else edited.
**Also corrected here:** `config.yaml`'s comment beside `export_price_eur_kwh`
still read *"no shipped supplier publishes a dynamic injection curve"*.
TARIFF-07 struck that claim from `app/price.py` and `DOCS.md` and did not reach
`config.yaml`, where it has been shipping since.
**20 mutations, every one red on a named check**, ledger in `test_price.py`
below section 17 with byte deltas — including a **zero-byte** one (the two legs
transposed in the VAT-asymmetry banner, which changes no decision and only
moves the sentence) and a **one-byte** one (`card_required=True` on the
injection leg). Three were run over all 29 files and are red on `test_price.py`
alone; the rest over the five suites that can reach this card. Each row gets a
fresh copy of the tree under a `mktemp` path, mounted `:ro` — no revert to fail
and no shared backup path, which is MUTATION.md habit 18 closed structurally.
29/29 green.
### TARIFF-17 - a price component that varies by hour has somewhere to live
**`price_taxes_profile`: the taxes component as a period table, alongside the
flat `price_taxes_eur_kwh`.** ⚠️ **The flat scalar was not a wrong number, and
this is not a correction of one.** The optimiser reads exactly two things off a
series — the spread `max − min` over the firm points, and which hour is
cheapest — and an additive constant identical in every hour cancels out of the
first and leaves the second where it was. It is *provably* inert. What was
missing was anywhere for an **hour-varying** non-energy component to live.
Belgium has one. Fluvius distribution is a single rate, and its row on the
tariff card reads `Normaal | Uitsl. nacht` — *exclusive night* being a separate
physical circuit, not a night register — so for the reference site in Flanders
nothing here changes. The Walloon DSOs and Sibelga are on the same card with
four columns, `Enkelvoudig | Dag | Nacht | Uitsl. nacht`, and the gap is real
money (c€/kWh): ORES `13,27 / 7,39`, AIESH `15,17 / 8,21`, Tecteo RESA
`12,20 / 7,01`, Sibelga `9,39 / 7,10`, ORES IMPACT 2026 `16,578 / 5,090`.
⚠️ **AND THE BANDS ARE ANTI-CORRELATED WITH WHAT THE BATTERY WANTS TO DO.** The
cheap network hours *are* the cheap spot hours, so flattening them does not
shift the curve — it **understates the spread** and declines cycles that would
have paid. Measured on one ordinary Belgian winter weekday, same feed, same
markup, the only difference being the taxes argument:
```
flat 0.0000 / 0.0739 / 0.1198 / 0.1327 / 1.0000 -> cheapest hour 13, spread 0.1500
ORES dag 0.1327 / nacht 0.0739 -> cheapest hour 03, spread 0.1788
```
Five different flat figures spanning and exceeding the table's own range give
**the same hour and the same spread to the last digit**; the table moves the
hour a battery would buy in from 13:00 to 03:00. That is the regression
`test_price.py` section 16 grades, and it grades **the hour**, not the spread:
an implementation that reads the table once and adds one number to every point
produces the right magnitude and the wrong shape, and a spread assertion passes
on it. `DOCS.md` now names the three buckets — LEVEL, SPREAD, ORDER — so the
next person adding a component knows which one it is in.
**The change is contained.** `static_tariff.py` already shipped the grammar —
periods tiling the day, gaps and overlaps refused, day types, DST — so it is
**the same parser**, taking the option name and the "what this number means"
clause as arguments. There is no second tiling rule, because a second one would
be a second set of 23- and 25-hour-day bugs; `test_static_tariff.py` section 10
pins that by parsing every module under `app/` and asserting the grammar is
defined in exactly one of them, and by deriving each of thirteen refusal
sentences for the new option from the old option's own sentence.
`Component.TAXES` semantics, `code_leaks()` and the double-counting guarantee
are untouched: the new key joins `FRAMEWORK_KEYS`, `BANNED_IN_PLUGIN_CODE` is
derived from that set, and a plugin naming it is refused at `register()`.
⚠️ **A MALFORMED TABLE IS REFUSED AT STARTUP, NOT AT THE NEXT FETCH.** It is
read on the ~30 s planning path through `assemble()`, and a table that first
fails at 03:00 is a site that stops pricing at 03:00 — which §11.4 turns into a
quiet fallback indistinguishable from a healthy fixed-tariff day. `validate.py`
parses it at startup, and refuses three things: a table that does not tile the
day (the same sentence `static_profile` gives, naming this key); a table set
*beside* a non-default `price_taxes_eur_kwh`, because the table wins and the
scalar would then be a number the operator typed that decides nothing; and a
whole card typed **in cents**, which is how these figures are printed. That
last rung is not a restatement of the parser's ±10 EUR/kWh bound — ORES's
`13,27` trips the parser, but Sibelga's entire card, `9,39` and `7,10`, is
under it, and would otherwise have started as a 9.39 EUR/kWh levy.
**Nothing changes for a site that does not set it.** The option ships `""`, the
scalar path is unchanged arithmetically — `test_price.py` 16f reproduces the
pre-TARIFF-17 expression and compares 12 capability/scalar combinations point
for point with `==` — and the reference site is in Flanders, where the flat
figure is correct. This is a product concern rather than a site one: the add-on
is sold to clients, and a Walloon or Brussels client could not express their
own tariff.
### TARIFF-18 - `price_taxes_eur_kwh` stops shipping at half the real figure
⚠️ **A SHIPPED DEFAULT CHANGED: `price_taxes_eur_kwh` 0.06 -> 0.11736 EUR/kWh.**
Same shape as 0.8.0's `slew_w` rule, and the same instruction follows — **read
the live options before `ha addons update`**, this time to see whether
`price_taxes_profile` is set, which is the one shape the move could have
refused. The "who is affected" section below is the part that matters, and it
is shorter on consequences than a changed default usually is.
The old `0.06` had **no recorded provenance anywhere**: not a card, not a date,
not a component list. It is roughly **half** the Flemish figure. The new default
is the Eneco residential card for Flanders, September 2026, incl. 6 % VAT, and
its rows are now **in the code** (`app/price.py`'s
`FLEMISH_TAXES_COMPONENTS_EUR_KWH`, re-added by `test_price.py` section 1b):
| component | c€/kWh |
|---|---|
| Fluvius distribution (**Antwerpen**) | 5,35 |
| Bijzondere accijns, *"Alle verbruik"* — no volume bands | 4,876 |
| Bijdrage groene stroom en WKK Vlaanderen | 1,51 |
| Energiebijdrage — **0 EUR/MWh since 2026-08-01**, merged into the accijns | 0 |
| **total** | **11,736 c€/kWh = 0.11736** |
⚠️ **IT IS PER-DSO, AND THE DEFAULT IS NOT AN AVERAGE.** Only the distribution
row moves: across the eight Fluvius DSOs it runs 5,28 c€/kWh
(Midden-Vlaanderen) to 6,70 (West), so the Flemish total runs about **0.117 to
0.131**. The default is a real DSO's real row, near the **low** end, and DOCS
tells an operator to look up their own. A **Walloon or Brussels** site should
not use this scalar at all — its distribution tariff has a day and a night band
and belongs in TARIFF-17's `price_taxes_profile`.
⚠️ **THIS IS A DISPLAY AND GUARD FIX. IT DOES NOT IMPROVE ARBITRAGE AND CANNOT.**
This scalar is a **LEVEL** component: an additive constant cancels exactly in
`max − min` and leaves the argmin where it was. TARIFF-17 shipped the machinery
and the proof — six flat scalars spanning and exceeding the whole per-DSO range
give the **identical** cheapest hour and the **identical** spread to the last
digit (`test_price.py` 16b, printed on every run), and none of that changes
here. No trade happens that did not happen before *because of the level*. What
does change is two things, and nothing else:
* **every number an operator reads** — the all-in prices on the status page,
`custom_formula`'s startup preview and the recorded price history. At half
the true non-energy component they made the add-on look considerably better
than it is; and
* **§17's negative-price guard** (`arbitrage.py`), the one rung that tests an
**absolute** all-in price rather than a difference. It fires when
`spot < −(markup + taxes)`, so its boundary moves **−0.09000 -> −0.14736
EUR/kWh of spot**. A −0.11868 EUR/kWh spot hour used to read **−0.02868**
all-in and the discharge was refused as paid-for disposal; at the real tax
level it reads **+0.02868** and discharges, because that hour genuinely
paid.
`test_arbitrage.py` section 2c drives both sides through the shipped
`decide()`, and pins the boundary from below as well.
⚠️ **AND THAT ASYMMETRY IS WHY THE DEFAULT SITS AT THE BOTTOM OF THE BAND.** Set
too **high**, the figure carries a genuinely negative hour above zero and the
add-on exports into paid-for disposal — §17's own case. Set too **low**, it only
declines a discharge that would have paid. One default standing in for eight
DSOs belongs at the bottom.
#### Who is affected
* **A site that set `price_taxes_eur_kwh` itself: nothing changes.** Its value
is kept and is never silently replaced.
* **A site whose stored options blob already carries the key: nothing changes
either, and this is most existing installs.** The Supervisor sets
`App.options = deepmerge(config.yaml defaults, stored options)`
(`tools/supervisor_selfapi_probe.py` §D), so a moved default reaches only
keys the blob does **not** carry — and the reference install's export carries
**70 of the 71**, the one absentee being a key added after its last save.
Such a site goes on running at `0.06` and reading numbers that are about half
its real all-in price until somebody opens the Configuration tab. ⚠️ **That
is a real limit of this card and it is not fixed here**: the change reaches a
**fresh install**, and an existing one only when its options are re-saved.
⚠️ **NOT re-measured on this branch** — the 70-of-71 figure is 0.9.0's, and
PKG-09's `tools/predeploy_check.py --options <live blob>` against the live
options is what would confirm it before deploying.
* ⚠️ **A site with `price_taxes_profile` SET would have been refused at startup,
and is deliberately not.** TARIFF-17 made a taxes period table beside a
**non-default** `price_taxes_eur_kwh` a `SystemExit(78)` refusal, comparing
against the shipped default precisely because the Supervisor writes the key
whether it was typed or not. Moving the default turns every stored `0.06`
into "non-default" **without anybody editing anything**, so a working Walloon
or Brussels site would have stopped starting on the upgrade over an inert
number the table overrides anyway. `price.py` now carries
`SUPERSEDED_TAXES_DEFAULTS_EUR_KWH = (0.06,)` and `validate.py` treats a
superseded default as *untouched* as well. **The rung is not weakened**: a
figure that is neither the shipped nor a superseded default — ORES's 0.1198,
say — is still refused, by name, and the refusal now says which of the two
figures it will accept (`test_validate.py`, four new checks plus the
difference precondition).
Nothing hardcoded `0.06` in that rung — it read `PRICE_OPTION_DEFAULTS` — which
is why the interaction is a *behaviour* change rather than a drift, and why it
had to be decided rather than noticed.
`config.yaml` and `PRICE_OPTION_DEFAULTS` moved together and CFG-03's tripwire
(`test_price.py` section 1, `test_defaults_pin.py`) stayed green by agreeing,
not by being widened. ⚠️ One check did have to be **rewritten rather than
re-pointed**: `test_price.py` section 0 used to justify its own grading
constants by observing that the shipped pair was degenerate — `0.06` is exactly
twice `0.03`. TARIFF-18 ends that coincidence, so the sentence is no longer true
and is not kept; the file now asserts per-figure that neither shipped default is
what it grades with, which is the property that was actually load-bearing.
### TARIFF-13 - the coverage figure beside the peak, and which quarter gets it
**The capacity-tariff status row's `N quarter(s) banked` is read from the
database instead of from process memory.** It was an `int` on `PeakTracker`,
starting at 0 and counted up inside `sync()`, printed next to a peak read from
SQLite. A 40-hour soak caught what that means at a restart, on both instances:
```
before: 2026-09: peak 365 W, set by the quarter at 2026-09-11T18:45:00+00:00
- 10 % of the 3500 W soft limit; 120 quarter(s) banked
after : 2026-09: peak 365 W, set by the quarter at 2026-09-11T18:45:00+00:00
- 10 % of the 3500 W soft limit; 0 quarter(s) banked
```
The peak is durable and was never wrong. The **count** is what says how much of
the billing month that peak covers, and 365 W over 120 quarters and 365 W over
0 quarters are different claims about the same number — so mid-month, after
every restart, the page made the weaker claim while showing the stronger one's
value. TARIFF-01's rule that an unreadable store must not read as a zero peak,
one column over. Two more defects in the same variable, neither in the ticket:
it was **never scoped to a month** (on 1 October the row still showed
September's tally beside October's empty month), and it **missed the block
`restore()` banks** from the checkpoint at startup.
⚠️ **AN UNREADABLE STORE NOW SAYS SO IN THAT CLAUSE.** Where the database will
not answer a count, the row reads `an unreadable number of quarter(s) banked`.
`0` was never available; `None` was rejected too, because `None quarter(s)
banked` reads as the same zero. `0 quarter(s) banked` stays true and reachable —
it is what a month nothing has been written to says.
⚠️ **AND A TIED PEAK'S ATTRIBUTED QUARTER IS NOW DECIDED: the EARLIEST wins.**
The wattage is what the utility bills, so this changes no bill and no guard —
`peak_w` is still only ever raised and SAFETY-07 reads the same watts. What it
changes is the answer to "when did my monthly peak happen", which an operator
goes and investigates; it now stops moving. The two readers of that record
**did** disagree: the `monthly_peak` upsert's strict `>` kept whichever tied
block was *written* first, while `recompute_month()` has always kept the
earliest — the same by accident only while blocks arrive in time order, and
measured to diverge (09:45 against 09:00) when they do not.
⚠️ **THE SOAK'S DRIFTING QUARTER WAS NOT A TIE, AND IS LEFT ALONE.** Driven,
exactly equal quarters never re-attributed at all. What moved the timestamp was
a genuine new maximum **below the row's whole-watt resolution** — 365.0000001 W
is a new peak to the database and the same `365 W` to the reader. That is the
instrument being right, and printing more decimals to explain it would put
noise in the one row an operator reads when the guard engages.
Reasoning in `DECISIONS/TARIFF-13-the-coverage-of-a-peak.md`; parts 11 and 12
of `test_tariff.py` drive a real restart — a second `Controller` against the
same file — and pin both decisions.
### TARIFF-11 - the plan's own account of itself, corrected and put on the page
**Four defects, one shape: every one of them made the add-on look better than
it was.** They shipped together because nothing in this repository graded the
strings a human is shown — every tariff check inspects the `TariffPlan`
*object*, and all four were in the *sentences* built out of it.
**1. `TariffPlan.words` counted points and called them hours.** The live
add-on logged `dynamic_dayahead from generic_dayahead, 132 h` for **132
quarter-hourly points = 33 hours**. Belgium moved to a 15-minute MTU on
2025-10-01, so on the real feed this was wrong every time it was printed, and
⚠️ **not by a constant factor**: measured across a 40-hour soak the
overstatement ranged **1.79× to 5.33×**, because §8.3's carried points are
hourly while the firm ones are quarter-hourly and the ratio moves with the mix
through the day. It now reads
```
dynamic_dayahead from generic_dayahead, 132 points over 33 h,
132 firm / 0 carried, 900 s spacing
```
— the same plan, with each number in its own unit. On the weekday morning that
plan is partly carried and reads `60 points over 33 h, 36 firm / 24 carried,
900+3600 s spacing, provisional` instead, which is the state the soak found an
operator could learn nothing about. The `N points over H h` wording is
FCST-04's *Price history* wording on purpose, so the two rows describing the
same feed can be compared rather than being two conventions on one page.
**2. The §8.3 and flat-tariff refusals did the same, and they reach an
operator.** `§8.3: only 1 of 96 hours carry a published price` is 96 points,
which is 24 hours; the flat rung counted the same points and called them `firm
hours`. ⚠️ **This is exactly the point≠hour conflation TARIFF-14 removed from
`at()`, left standing in the prose that describes it** — and it is not confined
to a log line, because `self.arb.explain()` puts it on the status page. Both
now print the two quantities separately: `only 1 of 96 points carry a published
price - 1 of 24 hours`. The same conflation in `price_forecast.py`'s §8.3
carry-forward log line — `%d of %d hours` with a carried-HOUR count over a
POINT count — is corrected in the same commit.
**3. The plan reached no HTTP surface at all.** `origin`, `product`, the
firm/carried split and the spacing appeared in **no** status row. `rows["Tariff"]`
was `static_status()`'s sentence, computed on the 30 s I/O-free tick from its
own static plan, and it **never saw the provider plan** — it read `'no static
profile'` at all **802** soak samples on a site whose feed was answering. So an
operator could not tell a working dynamic tariff from no tariff machinery at
all, and could not learn that the plan was `provisional` for 76 % of the soak
or mixed 900/3600 s for 70 %. The *Tariff* row now carries the plan.
⚠️ **The two halves of that row are not computed at the same moment and the row
says so.** `static_status()` runs on the 30 s tick; the provider plan comes off
the 1800 s background refresh and is served for up to `TARIFF_MAX_AGE_S`
(5400 s since TARIFF-12). So the plan half is stamped with **its own age**,
measured from `tariff_at` — which TARIFF-12 deliberately does not move on a
kept plan. A provider site with no usable plan says that too, rather than
falling silently back to the static sentence.
**4. `main.py`'s "if and only if" was false, and the row named an option that
was on.** TARIFF-10's comment asserted that `self.arb is None` **iff**
`arbitrage.enabled(self.o)` was False. `cycle()` returns at the input hold —
inputs missing, `bad_for < stale_input_s`, 15 s by default — **before** it
reaches `self.arb = None`. Driven: `arbitrage_enabled: true` plus a sensor
answering `None` gives `arbitrage.enabled(opts) = True`, `self.arb = None` and
a row reading `off (arbitrage_enabled)`. Past the first completed cycle the
same early return leaves the **previous** decision standing, which the row
rendered as a current one, up to ~15 s stale. The row now distinguishes three
facts with three remedies — trading is off; trading is on and this cycle
reached no decision; a decision, with its age — and it reads the **option**
rather than inferring it from a missing decision. The comment states what is
true.
⚠️ **THE DELIVERABLE IS THE CHECK, NOT THE FIXES.** All four survived 29 green
suites because no check in this repository had ever read a rendered row.
`test_price.py` section 12 renders through the shipped `Controller.status_payload()`,
parses each number out of the row **by its own slot**, and compares it against
a figure computed from the fixture's own construction parameters — never from
the property the row was built out of (MUTATION.md habit 4). It is deliberately
**not** a substring test over a sentence the same file wrote: `"132 points" in
row` is satisfied by the number appearing in the *other* number's slot, which
habit 14 shows is a zero-byte edit away. The fixtures are a **set** of four
plan shapes, and the check computes and prints the table of field pairs no
fixture separates — `none` — so a pair that became degenerate would go red
rather than quietly vacuous. The *Arbitrage* row's three states are driven
through real cycles with a sensor answering `None`, and graded by
**inequality**: two facts that must not render identically.
**Nothing about what the battery decides changes.** No threshold, no refusal
rung, no claim, no setpoint. Every edit is to a sentence, to a derived counter
behind one, or to where a sentence is rendered.
### TARIFF-15 - your own tariff card, as two coefficients
**New price provider `custom_formula`, and one new option, `price_formula`.**
A Belgian dynamic contract prices energy as `B × index + A`; the two
coefficients live on the customer's own tariff card and **nowhere else**.
There is no machine-readable source for them anywhere — CREG's consumer
tariff-card pages 404, CREG Scan is a JavaScript wizard, the annual report
carries the supplier list without per-product coefficients, VREG was
unreachable, and every coefficient found in research came off a supplier's own
PDF, one image-only. So there is nothing to scrape and a per-supplier plugin
would have no source for its numbers — which is precisely why TARIFF-07
withdrew three of them. **The customer is the only party who can see their own
coefficients.** They type them, once:
```json
{"index": "epex_be", "resolution": "hourly",
"factor": 0.102, "offset": 1.00,
"units": "c_eur_per_kwh", "vat_pct": 6,
"card": {"month": "2026-09", "index_eur_per_mwh": 133.9905,
"expect_incl_vat": 15.55}}
```
`price = (factor × index_eur_per_mwh + offset) × (1 + vat_pct/100)`, in
`units`, **converted to EUR/kWh by the add-on**. The operator types what the
card prints, in the card's own units; every unit conversion and the VAT
multiplication are the add-on's job, because those are the two steps that
silently cost a factor of 10, 100 or 1.06.
**The index is `generic_dayahead`'s, not a second one** — same EPEX BE feed,
same Brussels-calendar range request, same columnar parser, same declared
egress hosts. The URL decision is now one function both plugins call, so a
short-horizon or override bug cannot exist in one and not the other.
`resolution: quarter_hourly` emits the feed's 96 points as they are;
`hourly` averages each hour's members. Neither is `_Series.at()`'s hourly
assumption returning: it decides how many points are **emitted**, and the
window each one covers is still derived from its neighbours (TARIFF-14).
⚠️ **It declares `{ENERGY, MARKUP}`, not `ALL_IN`, and that is the whole safety
argument.** A Belgian card's `Tariefformule` line is the **energy component
only** — Eneco tabulates network tariffs in one table and levies in a second,
ENGIE states that the formula excludes network, distribution, transport, grid
levies and excise. Declaring `ALL_IN` would lie on behalf of every operator who
typed exactly what their card says, and would drop `price_taxes_eur_kwh` from
every hour. Measured: 0.2125 → 0.1555 EUR/kWh, silently.
⚠️ **THE CARD IS THE GRADER, AND IT IS WHY THIS IS SAFE TO SHIP.** The
framework already mechanises that a *plugin* cannot double-count
(`PluginOptions`, `FRAMEWORK_KEYS`, `code_leaks()`). This provider introduces a
risk none of those can see, because it is **config, not code**: the *operator*
double-counting, by folding network charges into `offset` while
`price_taxes_eur_kwh` carries them too. So:
> At startup `validate.py` computes
> `(factor × card.index_eur_per_mwh + offset) × (1 + vat_pct/100)` and
> **refuses to start** unless it equals `card.expect_incl_vat` to within
> `0.01`, naming the discrepancy, the ratio and the likely causes.
An inflated `offset` **cannot pass**: the printed estimate is the energy
component alone, so ~12 c€/kWh of network charge moves the computed 15.55 to
28.27 and the add-on stops. The same check catches VAT omitted, VAT applied
twice, a transposed digit, and a unit mismatch between the coefficients and the
printed price.
⚠️ **And the limit, in the same sentence as the claim: it grades the
coefficients against the card, not the card against reality.** A
consistent-but-wrong pair — both numbers off the wrong product — reproduces its
own printed price perfectly and passes. Nothing can catch that. A **second**
refusal covers the one unit error the first cannot see, the one applied to both
sides at once: the card's own point must land inside 0.02–1.00 EUR/kWh. Its
floor is applied to the **energy** figure rather than the all-in one, because
the shipped 0.06 of taxes is three times that floor and would carry a
hundredfold error over it on its own — measured, and driven red by a mutation.
**The market's own arithmetic, reproduced to the digit the supplier prints.**
Both cards that were readable print the formula, the index they assumed *and*
the resulting price:
| | computed by the shipped code | the card prints |
|---|---|---|
| Eneco `(0.102 × 133.9905 + 1) × 1.06` | **15.5471** | **15,55** |
| ENGIE `(0.1 × 61.96 + 0.9) × 1.06` | **7.5218** | **7,522** |
⚠️ **No expression evaluation of any kind, and a check that fails if one ever
appears.** `price_formula` takes numbers; there is no field that accepts an
expression and an **unrecognised field is refused rather than ignored**, so
typing `"expr"` is told it does not exist instead of quietly pricing the site
on the fields beside it. Two reasons, and the second decides it:
* the string is settable over HTTP — the add-on's own ingress page posts it to
`/addons/self/options` — so `eval` on it is RCE in a root container holding
`SUPERVISOR_TOKEN`, with `homeassistant_api` and `hassio_api`, driving an
inverter over RS485;
* **an expression is unverifiable.** Two coefficients can be graded against the
card's printed price; an arbitrary expression cannot be graded against
anything, so it would make the invisible-wrong-coefficient problem *strictly
worse* — the exact failure this provider exists to prevent.
All 24 surveyed Belgian products, both injection legs and aWATTar AT fit
`B × index + A`. Future shapes become **named fields** (`clamp_lo`,
`factor_negative`, `offset_bands`), each individually refusable and each
gradeable against a card. Never a grammar. `test_price.py` 15f walks
`app/custom_formula.py`'s AST for `eval`/`exec`/`compile`/`__import__`/
`literal_eval` and exercises the scanner's **red** direction on every run.
**Refused at startup, not at 03:00.** `card` absent or failing by more than
0.01; `units` absent (no default, on purpose — the same convention is printed
two ways by two suppliers); `factor == 0`, which makes every spread 0 and
arbitrage silently never fire (the message points at `static_profile`, which is
the first-class way to say "one price"); `factor < 0`, which inverts the market
so the battery charges at the evening peak; `vat_pct` outside 0–30 (**0 stays
legitimate** — injection is VAT-exempt and some cards are already VAT-inclusive);
a non-finite or non-numeric coefficient; an unknown field; an unknown `index` or
`resolution`; and the plausibility band above. A `card.month` older than about
six months **warns and does not refuse** — ENGIE freezes coefficients for a
contract's duration, so an old card is often exactly right.
⚠️ **Negative output prices are NOT refused.** They are legal on EPEX and they
are the best charging hours of the year (§17 keeps the regression case). The
card check bounds the formula's *magnitude* without constraining the sign of
any hour.
**A startup preview, so a factor of 1000 is visible in one line.** The first
time the feed answers, the add-on logs the next 24 h as
`index EUR/MWh -> all-in EUR/kWh` with the min, median, max and the day's
spread. It is a new framework hook (`PriceProvider.startup_preview()`, default
silent) rather than a line in `load_prices()`, because only the plugin knows
what went *in* to its own arithmetic; it is emitted once per process and it
cannot stop a fetch — a preview that raises is caught and logged.
**Surfaces.** `config.yaml` gains `price_formula` (options **and** schema) and
`custom_formula` joins the `price_provider` enum through the **derived** set
`PROVIDERS | RETIRED_PROVIDERS | {"off"}` rather than a hand-typed list; both
translations describe the option and the new id. `DOCS.md` replaces the
"planned" sentence with the shape, a worked example from a real card, the
startup transcript, and the limit of the check stated in the same sentence as
the claim.
**Not in scope, and each is a card of its own:** the injection leg's own
coefficients (Eneco uses 0,102 on consumption against 0,100 on injection, and
injection is VAT-exempt where consumption is at 6 %); the hour-varying network
charge that bites Wallonia; raising the `price_taxes_eur_kwh` default from 0.06
to ~0.12.
### TARIFF-07 - three plugins that never fetched a price, withdrawn
**`engie_dynamic`, `totalenergies_dynamic` and `eneco_eddy` are gone from
`PROVIDERS` and from every surface that listed them.** They did not stop
working. **They never worked.** Verified by hand on 2026-09-13, before anything
was deleted:
| id | endpoint | observed |
|---|---|---|
| `engie_dynamic` | `https://api.engie.be/dynamic/be` | **404**, Kong `no Route matched with those values` |
| `totalenergies_dynamic` | `https://api.totalenergies.be/prices/dynamic` | **TLS failure** — cert is `CN=pge-apigee-dev.direct-energie.com`, host not in the SAN list |
| `eneco_eddy` | `https://api.eneco.be/eddy/prices` | **404**, empty body |
They are also **structurally impossible**, not merely unfinished. ENGIE's
`(B × eSpot_15) − A` coefficients are per-contract and sit behind the
klantenzone login, so no public unauthenticated endpoint could return a given
customer's price; there is no regulator index to read coefficients from; and
**"Eddy" is not an Eneco product at all** — Eneco's dynamic product is *Zon &
Wind Dynamisch*, indexed to Belpex/EPEX **day-ahead**, not imbalance.
**The schema keeps all three ids on purpose, and that is the whole reason the
refusal is reachable.** `price_provider` is a `list(off|…)` enum and the
Supervisor validates the options file against it *before the add-on runs*. Drop
a retired id from the enum and an existing config naming it becomes
schema-invalid: the operator gets an opaque `expected one of ...`, the add-on
never starts, and `validate.py`'s message is never seen — on exactly the sites
that need it. `PROVIDERS` is two; the enum stays six. `test_price.py` asserts
the schema offers exactly `PROVIDERS | RETIRED_PROVIDERS | {"off"}`, derived
rather than typed, and `register()` refuses to re-register a retired id so the
refusal cannot be taken away by an `@register` somebody adds back.
**`PriceProduct.REALTIME` and the widening path survive with no shipped
declarer.** `eneco_eddy` was their sole declarer, so `_WIDE`,
`Uncertainty.REALTIME_PRODUCT` and `WIDEN_FACTOR`'s 2.5 now have none. They are
kept: it is the AC2 seam — declare `REALTIME`, get the wide regime, edit no
framework code — and the first real imbalance product would otherwise have to
rebuild it. ⚠️ **No shipped plugin declares `PriceProduct.REALTIME` until one
does**, `test_price.py` section 5 pins that so the emptiness reads as intent
rather than a dead branch, and section 10 keeps the path live from a class
declared outside `price.py`. See
`DECISIONS/TARIFF-07-withdrawing-three-plugins.md`.
⚠️ **FOUR FALSE CLAIMS ARE CORRECTED, AND THEY ARE WHY THIS CARD EXISTS.**
* `eneco_eddy` was called a "Belgian imbalance product" in `DOCS.md`,
`app/price_forecast.py`, `app/price_history.py`, `app/static_tariff.py`,
`DECISIONS/FCST-04-the-day-that-is-carried.md` and twice in this file. It is
**false** — Eneco's dynamic product is day-ahead-indexed. The two historical
entries here are **annotated in place** rather than rewritten; the record of
what the project believed is part of the record.
* The quarter-hourly examples those surfaces used `eneco_eddy` for are now
**Belgian day-ahead itself**, which really does settle per quarter since the
15-minute MTU of 2025-10-01 — `generic_dayahead` reads 96 points a day. The
mechanism was always right; only the example was invented.
* `export_price_eur_kwh`'s docstring claimed *"no shipped supplier publishes a
dynamic injection curve"*. **Also false.** Eneco publishes
`0,1 × BELPEX-H − 1,188` on the same card as its consumption formula,
identical on the January and September 2026 cards, and ENGIE publishes
`(B × eSpot_15) − A`. What is true: an injection curve is the **same
two-coefficient shape** with **its own** coefficients and its own VAT
treatment — injection is VAT-exempt, consumption is at 6% — so the scalar is
a **simplification an operator enters by hand, not a reflection of the
market**. `DOCS.md` says the same.
* `_points_from_json()` is deleted with the plugins it served. It read a
`{"data": [...]}` document **no feed anybody here has ever reached
publishes** — invented alongside these three, and graded only against
fixtures written from the same guess. TARIFF-08 found that loop on the
response side for `generic_dayahead`; this is the rest of it.
**`DOCS.md` now answers the question a Belgian dynamic customer actually has.**
The provider table is two rows. The new prose is explicit that
`generic_dayahead` gives wholesale EPEX BE plus flat markup and taxes scalars,
which **approximates** a retail dynamic tariff and **cannot express
`B × spot + A`** — it has no multiplier, and it cannot represent a negative
offset, which `price_markup_eur_kwh: float(0,1)` could not hold in any case. A
formula provider is named as the planned answer and is a separate card.
*(Annotated 2026-09-13: TARIFF-15 replaced that sentence. The table is three
rows and the prose points at `custom_formula`.)*
⚠️ **One check had to be rebuilt rather than deleted.** `test_price.py` 4b
proved `code_leaks()`'s docstring strip is load-bearing by finding a shipped
docstring a raw scan false-positives on — and that docstring was
`engie_dynamic`'s. With it gone the check would have **passed on a tree with
the strip deleted**: a check that had quietly stopped being one. The stimulus
is constructed in the test file now, and the shipped set asserted clean
separately.
Nine mutations driven, all red; the table is in the decision record. Two carry
a **+0 B** delta and two end in a traceback whose red count is therefore a
lower bound — both flagged there, per `MUTATION.md`.
### TARIFF-10 - a configured provider is fetched, whether or not you trade
**`amain()` started the background tariff refresh only when
`arbitrage_enabled` was on, and that option ships `false`.**
`run_tariff_refresh` is the only caller of `resolve_tariff()`, which is the
only caller of `price_history.carry()` - so on a shipped install with a price
provider configured **nothing was ever fetched**: no plan resolved,
`/data/price_history.json` never created, the *Price history* status row
reading `empty` for the life of the install, and TARIFF-09's short-horizon
warning unable to fire because there was no fetch to warn about.
Measured over a 40 h soak of two instances side by side on the same feed:
| | shipped default + provider | same, arbitrage armed |
|---|---|---|
| feed requests | **0** | fetching |
| `/data/price_history.json` | `present: false` on **all 802 samples** | written |
| resolved plan | none | 132 points |
⚠️ **`DOCS.md` has described the fixed behaviour since the commit that wrote
the gate.** OPT-04 (`bdd7f18`) added the refresh task, the
`arbitrage.enabled()` guard on it, and the sentence *"turning a provider on
still fetches, validates and publishes prices and changes no charging
decision"* — all in one change. `config.yaml` has said the same since
TARIFF-02 (`852fc7c`). The documentation and the code have therefore disagreed
for as long as both existed, and nothing compared them. `config.yaml` and both translations carried the same
claim, plus a second one that had gone stale in the other direction (*"nothing
consumes the price series yet"*, untrue since OPT-04). All four now say what
the add-on does.
**The gate is `tariff_refresh_wanted()`, and it is a STRICT WIDENING.**
```
provider_configured(opts) or arbitrage.enabled(opts)
```
Every configuration that started the refresh before still starts it. The second
term is not redundant and is not there for symmetry: `price_provider: off` with
a `static_profile` and `arbitrage_enabled: true` is a configuration
`validate.py` explicitly **accepts**, and it trades - measured, at
`cycle_cost_threshold_eur: 0.05` on a 0.20/0.284 EUR/kWh day/night profile,
`ARBITRAGE_CHARGE -5000 W`. Gating the refresh on the provider alone would
leave that site's `tariff_plan` at `None` forever and answer *"no tariff plan
has been resolved yet"* on every cycle - silently disarming a strategy the UI
says is running.
⚠️ **Nothing acquires a periodic HTTPS call from this.** With `price_provider`
off, `resolve_tariff()` answers out of the static profile without opening a
socket; and the true shipped default - no provider, no trading - starts **no
task at all**. What decides whether a request leaves the machine is
`price_provider`, and only that.
⚠️ **AND NOTHING TRADES THAT DID NOT TRADE BEFORE.** `cycle()`'s
`if arbitrage.enabled(self.o):` is untouched. Graded directly rather than
inferred from the gate having moved: `Controller.cycle()` is driven on a
resolved provider plan whose cheapest firm hour is now, with the peak guard
asserted clear, and `arbitrage_enabled` is the single option that moves between
the rows.
| `arbitrage_enabled` | cheapest hour is now | commanded |
|---|---|---|
| `false` | yes | **+180 W** (`loop -> 180 W`) |
| `false` | no | **+180 W** (`loop -> 180 W`) |
| `true` | yes | -5000 W (`arbitrage -> -5000 W`) |
| `true` | no | +5000 W (`arbitrage -> 5000 W`) |
**`TariffPlan.cheap_now()` is deliberately NOT wired, and that is now a
decision rather than an inheritance.** A provider-backed plan exists on every
configured site from this commit, so *Cheap window* - which feeds the
maintenance cycle's grid top-up, i.e. the one place a price reaches something
that **moves energy** without trading being armed - could now read it. It does
not: `self.cheap` still comes from `static_status()`, and on a provider-only
site (`static_profile` empty) that is `False` on every cycle, so no paid grid
top-up is ever forced. Wiring it would take that from *never* to *sometimes*.
`DECISIONS/TARIFF-10-fetching-is-not-trading.md` §4 carries the argument and
the list of what adopting it would take.
**The check that would have caught this** is `test_price.py` section 13, and it
grades **reachability from a configuration**, not the shape of an `if`. The
guards in `amain()` are *evaluated* against real option dicts, whatever they are
spelled as; the call graph under `app/` is walked to see whether the tasks those
guards start can arrive at `resolve_tariff()`, wherever it has moved to; and
then the fetch is **driven** with a counting transport, because a graph is an
argument and a counted request is an observation. The shipped defect - the gate
back at `arbitrage.enabled(opts)`, **-4 B** - is red on seven named checks.
### TARIFF-12 - a returned degradation is not a refresh
**`run_tariff_refresh()` promised in its own docstring that "a failure does not
clear the plan", and enforced it with `except Exception` - a branch a supplier
outage never reaches.** `load_prices()` states the reason in its own words: it
"RETURNS, NEVER RAISES, for every failure a site can actually have", because a
degradation arriving as a traceback into the planning tick would stop the
controller regulating over an expired certificate. So a dead feed **returns** a
§11.4 plan, the `try` succeeds, and the assignment below it overwrote the good
plan unconditionally. With `static_profile` unset - the shipped default, and the
normal state of a dynamic-tariff site - `_degrade()` returns
`TariffPlan(no_data, None, "none")`: **a complete 48-hour plan replaced by
nothing.**
Measured in a 40-hour soak, `static_profile` empty, a 90-minute outage driven:
| Brussels | refresh | plan |
|---|---|---|
| 17:26:12 | 55 | `dynamic_dayahead from generic_dayahead, 141 h, provisional` |
| **17:56:12** | **56** | **`no tariff - generic_dayahead: ClientConnectorError: Cannot connect to host`** |
| 19:26:12 | 59 | restored, one refresh after the feed returned |
`origin: none`, `n_points: 0` for all 30 outage samples. The plan was gone ~27
minutes after the last good fetch, **at the first failure** - so
`TARIFF_MAX_AGE_S` (5400 s) never governed anything, and there was no
serve-stale window at all: a transient blip cost exactly what a long outage did.
**The question is now asked once, after the attempt, from the evidence that
exists** - FCST-06's answer, one module over. The evidence is
`TariffPlan.from_feed` (did this resolution observe the configured feed) and the
shipped `fresh_tariff_plan()` (is an observation still current). A degradation
replaces a standing observation only once that observation has **aged out**, so
`TARIFF_MAX_AGE_S` is now the serve-stale window it reads like.
**A §11.4 static fallback does not replace a fresh provider plan either**,
although it carries real prices. Every point `_degrade()` builds is
`provisional=True`, so `firm_points()` is empty, `arbitrage()` refuses and
`cheap_now()` is False - everything a consumer may act on is already off - while
a day-ahead price for a given hour does not change once published. The fallback
is less actionable and no more current; it takes over when the observation
retires, which is what §11.4 is for. The rule is **not** symmetrical: a standing
plan that is itself a degradation is replaced by the next one, or an outage
would freeze the operator's static profile at the window it was first generated
for.
**`tariff_at` does not move on a kept plan.** It is the moment of the fetch that
produced the plan standing, `fresh_tariff_plan()` judges the age from it, and an
unmoved timestamp is the only thing that tells a kept plan from a freshly
fetched one. Re-stamping it would be the refresh asserting the feed answered
when it did not - the "freeze at its last value and look current forever" hazard
the same docstring names.
**What did NOT change.** The persisted price history still does not back the
plan during an outage: FCST-03 exists to stop stale prices being acted on, and
"recent" is not "current". Nothing about the control loop, the arbiter, or the
30 s tick - `cycle()` still reads two attributes and awaits no fetch.
`test_arbitrage.py` section 8b drives the whole chain with **nothing stubbed but
the socket**: the transport raises the way aiohttp does, `load_prices()` returns
`no_data`, `_degrade()` builds the §11.4 plan, and the shipped
`run_tariff_refresh()` decides. A check that patched `resolve_tariff` to *raise*
would have passed against the defect. Eleven mutations, eleven reds, no
survivors - see `DECISIONS/TARIFF-12-a-degradation-is-not-a-refresh.md`.
**Merged after TARIFF-10, which widened *which installs run this task*, and the
two configurations it newly keeps alive are graded rather than reasoned about.**
A provider with trading disarmed is the case this guard was designed for and is
covered by every driven check here, because nothing in `run_tariff_refresh()`
reads a trading option at all - asserted on the AST symbols rather than on the
source text, after two drafts of that check went red on a correct tree for
saying "arbitrage" in a docstring and in a log line. `price_provider: off` + a
`static_profile` resolves to the CONFIGURED product (`origin: "static"`), so
`standing.from_feed` is false on every refresh and the guard never latches: the
plan is regenerated for the current window exactly as it always was. Both are
driven, and a mutation that makes the guard depend on `arbitrage.enabled()` is
red on five named checks.
### TARIFF-14 - the trade was decided against the wrong price
**On the only price feed that works, `_Series.at()` returned the wrong point,
and the error grew with depth into the series.** It asked
`s <= u < s + 1 h` of every point **in list order** and returned the **first**
match. On the hourly shape every fixture in this repository carried before
TARIFF-08 that is right by accident; Belgium moved to a **15-minute MTU on
2025-10-01** and the live day-ahead feed returns **96 points at 900 s**, where
it is wrong twice over. Measured against the shipped code at `5059e28`:
```
series: 02:00=0.10 02:15=0.11 02:30=0.12 02:45=0.13 03:00=0.14 ...
ask + 0min -> 02:00 0.10
ask +15min -> 02:00 0.10 <-- WRONG (wanted 02:15)
ask +45min -> 02:00 0.10 <-- WRONG
ask +60min -> 02:15 0.11 <-- WRONG (wanted 03:00)
ask +75min -> 02:30 0.12 <-- WRONG (wanted 03:15)
```
Inside the first hour the `:00` point wins because its hour has not run out.
**From the second hour on the answer is not even the top of the hour** - the
first point still inside its own hour wins - so the error compounds.
**What it cost is not "a slightly wrong price".** `arbitrage._act()` tests
`here.start == v.cheapest.start` / `== v.dearest.start` to decide whether this
interval is the buy one or the sell one. That identity almost never held, so
**the strategy idled through exactly the interval it exists to trade**,
reporting *"this hour is neither the buy hour nor the sell hour"* - and read
§8.3's `here.provisional` and §17's `price < 0` off the same wrong point.
`static_tariff.py` emits hourly points, so **static sites were never affected**;
this was reachable only down the dynamic path TARIFF-08/09 made work.
**The rule now, in one sentence: a point covers from its own start until the
next point's start, and never more than one hour.**
| | before | after |
|---|---|---|
| 900 s | `at(02:15)` -> the 02:00 point | -> the 02:15 point |
| 3600 s | `at(02:30)` -> the 02:00 point | **unchanged** |
| **mixed** `[900, 3600]` | each point one hour wide | **each point takes its own gap** |
The mixed case is not an edge case: FCST-04's carry-forward emits **hourly
carried points beside quarter-hourly firm ones**, and the soak measured spacing
`[900, 3600]` in **70 % of samples**. A window derived from one global spacing
would be wrong in the normal steady state.
**The one-hour cap is load-bearing.** FCST-04 leaves an hour *out* of the
series when nothing published it and yesterday has no value either, and
`at()` raising `Absence` for that hour is what sends the caller to the static
profile (§11.4). Uncapped, "until the next point's start" would stretch the
point before a three-hour hole across the whole hole and answer every instant
in it with a stale price - filling holes, introduced by the fix for a different
defect.
**The last point's window is a decision and it is written down.**
`DECISIONS/TARIFF-14-the-window-a-point-covers.md` §2 argues it: the last point
is given **the same span as the point before it** (one hour when it is the only
point). A flat one-hour tail would answer **00:30 tomorrow with today's 23:45
price**, which is reaching for a neighbour across a day boundary. The cost of
the choice - a mixed series ending at the firm/carried seam loses its last 45
minutes to `Absence` - is stated there rather than buried, and the direction is
the safe one.
**`at()` now reads a point's neighbours, so it would depend on the series being
sorted - and it establishes that itself** rather than trusting the three
producers that happen to guarantee it today. The lookup index is sorted by UTC
start once, at construction; a series handed its 96 points in reverse order
answers identically, which is a check. `covers()` shared the defect exactly
(it has no rule of its own - it asks `at()`) and is fixed by the same change;
`window()` did not (it grades a point's **start** against a range and asks
nothing about duration), and its docstring now says so.
**Nothing about §9.3 or a point's `start` changed.** `PricePoint` still has
three fields; the span is derived from the neighbours, not stored.
Graded by `test_price.py` section 14 - 900 s, 3600 s, **mixed**, holes, the
tail, caller order, `covers()`/`window()` - and end to end by
`test_arbitrage.py` section 10, which drives `decide()` over a 96-point
quarter-hourly day whose cheapest and dearest quarters are deliberately **not**
on a whole hour. Eight mutations, all red, including a **zero-byte** one on the
tail rule; the table with byte deltas and the checks that were NOT reached is
in the decision note §6.
### TARIFF-09 - the feed is asked for the range the caller wanted
**`generic_dayahead` took `since` and `until` and requested the bare feed URL,
which answers one Brussels day.** Everything past today was then filled from
yesterday's profile by FCST-04, flagged provisional, and §8.3 drops provisional
hours from the trade set - so **the optimiser never saw tomorrow as firm, at any
hour of any day.** Measured on `4257e38` at 2026-09-10 09:00 CEST over the
shipped 48 h horizon, live feed, yesterday seeded:
| | 48 h horizon, one-day feed |
|---|---|
| firm | **15 whole hours** (60 quarter-hour points) |
| carried, provisional | **33 hours** - 24 on D+1, 9 on D+2 |
| permitted cycle | buy 11:45, sell 19:45 - **both on 2026-09-10** |
| firm local days | `[2026-09-10]` |
The ceiling was structural, not incidental: with a one-day window, at hour *H*
of the local day a 48 h horizon is at most **24−H hours firm and 24+H carried**.
At 23:00 that is **1 firm hour and 47 carried**, and the remaining firm spread
(0.0464 EUR/kWh) no longer clears the default 0.10 round-trip threshold at all -
so arbitrage was refused outright. This is **not** what FCST-04's fill is for:
that covers the window until the ~13:00-14:00 CET auction, after which a healthy
feed publishes tomorrow in full.
**The data exists and the endpoint serves it.** Verified 2026-09-10T07:45:49Z:
`?bzn=BE&start=2026-09-09&end=2026-09-10` returns 192 quarter-hours across two
local days, committed unmodified beside TARIFF-08's captures. The plugin simply
never asked.
**The range is now derived from `since`/`until` on the BRUSSELS calendar**, as
two inclusive dates. Not the UTC calendar: 22:30 UTC in summer is already
tomorrow in Belgium, so a UTC-derived start asks for the day the controller has
just left and drops the day it is standing in, for the last one or two hours of
every day. That is `price_history._bdate()`'s lesson one layer up, with a worse
consequence - `_bdate()` misfiles an hour, this never fetches it. `until` is
exclusive, so a horizon ending exactly at local midnight asks for one day fewer
than the naive reading gives, and an inverted window collapses to a single day
rather than a backwards range.
Same code path, same window, a feed serving both days:
| | before | after |
|---|---|---|
| firm hours of 48 | 15 | **39** |
| carried, provisional | 33 | 9 |
| firm local days | 1 | **2** |
| permitted cycle | one calendar day | **buys on one day, sells on the next** |
The 9 remaining carried hours are the tail of the horizon that runs into a third
Brussels day, which no day-ahead market publishes. FCST-04 still fills them and
still flags them; what changed is what is firm, never what may be acted on.
**Before publication nothing regresses, and that is graded rather than
assumed.** Asking for tomorrow before the auction returns fewer days than
requested - measured, at 09:46 CEST the two-day request came back byte-identical
to the one-day body - and that stays a `series` of what exists, with FCST-04
filling the remainder. A `no_data` there would switch a working site's arbitrage
off every morning.
⚠️ **`price_feed_url` is the EXACT URL and the plugin appends nothing to it, so
an overriding site keeps the short horizon.** That is a decision, not an
oversight: `start`/`end` are this feed's spelling, the provider declares a second
host whose parameters are different, and rewriting a URL an operator typed is
how a request nobody intended gets made. **It is not silent** - the plugin logs a
`WARNING` at fetch time naming the consequence and the `start..end` it would
otherwise have asked for. See
`DECISIONS/TARIFF-09-the-range-and-the-override.md`.
The plugin contract - `fetch(self, opts, since, until, transport)` hands every
plugin the range - is still **not** enforced, because three shipped plugins point
at endpoints nobody has verified and a rule obliging them to pass a range would
be satisfied by an invented parameter name. Which plugins consume the range is
pinned as a literal in `test_price.py` instead, so the next supplier has to
decide rather than inherit the silence.
### FCST-06 - the second way to be a store that cannot persist
**A price cache that could not write went on answering a yesterday the file did
not contain.** `price_history.py`'s docstring states its rule unconditionally -
*"A store that cannot persist now records nothing, and both of its answers say
the same thing"* - and FCST-04 enforced it against `not self.ok`, which is one
**symptom**: the durable volume is missing. `ok` is about the DIRECTORY, and a
read-only remount and a full disk both leave it `True`. Reproduced on `5059e28`
against two real volumes - a `/data` bind-mounted read-only and a full tmpfs:
| | with a `/data` that cannot be written |
|---|---|
| `last_error` | `could not write ([Errno 30] Read-only file system)` |
| `words` | `2026-01-14 (24 points over 24 h); 2026-01-15 (24 points over 24 h) [could not write (...)]` |
| `yesterday()` | **series, 24 points** |
| on disk | `{}` |
`words` and `yesterday()` were describing two different stores, and the 24
points were gone on the next restart with nothing saying so - the
silently-forgetting cache that rule exists to refuse, reached by the condition
it did not name. **No shipped path reaches it**: `/data` is the Supervisor's
durable volume and this module is its only writer. The defect is that a
guarantee the module states about itself did not hold in one condition.
**"Cannot persist" is now ONE derived predicate, asked once, about the
outcome.** It cannot be answered *before* the attempt - a directory that existed
and was writable a moment ago is not a write that completed - so `_save()`
returns whether the file now holds what memory holds: `False` with no durable
volume, `False` on an `OSError` from the write, `True` otherwise. `_remember()`
keeps only what that one answer says was kept, and **the `not self.ok` test in
`_remember()` is gone** rather than joined by a second one. FCST-04's M4 and
FCST-05's HIGH were the same shape - a rule enforced on the conditions somebody
thought of - so a third cause now needs no third branch.
**What is undone is the MERGE, not the store.** The state restored is the last
one that *is on disk*, so a site whose volume fills at 14:00 goes on answering
the yesterday it wrote at 13:30 - that record survives a restart, so answering
it is not a promise the store cannot keep. It simply stops adding to it. The
snapshot is a `copy.deepcopy`: a one-level copy shares the day record the merge
rebinds `points` on, and measured with one, a store holding 12 persisted points
answered **24** after a failed merge.
⚠️ **A failed write is still not fatal, and that was a constraint rather than an
oversight.** §6 and this module's opening: a broken cache must not be a broken
controller. An add-on that will not start because `/data` filled up is a worse
defect than the one being fixed, so `_save()` reports and returns - the failure
stays in the log, in `last_error`, in `words` and in `yesterday()`'s reason -
and the shipped `resolve_tariff()` path still returns a provider plan with no
§11.4 degradation. What changed is that it is now *acted on*.
`test_price_history.py` section 5d drives it on two real failures with different
syscalls and different errnos - a directory where the file goes (`os.replace`,
EISDIR) and a volume that moves out from under an open store (`mkstemp`,
ENOENT) - because the rule is enforced on the outcome and one cause would grade
a coincidence. See `DECISIONS/FCST-06-cannot-persist-is-one-question.md`.
### TARIFF-08 - no network price provider had ever parsed a live response
**`generic_dayahead` could not read one byte of `api.energy-charts.info`, and
had never been able to.** `_points_from_json()` asks for `doc["data"]`, a list
of `{start, price_eur_mwh}` objects. That document does not exist. Fetched live
on 2026-09-10, the feed returns **columnar** parallel arrays and no `data` key
at all:
```
top-level keys: ['deprecated', 'license_info', 'price', 'unit', 'unix_seconds']
unix_seconds: 96 UTC epoch seconds, first 1788991200, spacing 900 s
price: 96 floats, first 216.08
unit: 'EUR / MWh'
```
Driving the shipped parser against that body: `SourceUnavailable: the feed
carried no 'data' list`. Since `generic_dayahead` is the only shipped provider
whose endpoint anybody has reached, **dynamic pricing did not work at all**.
⚠️ **AND §11.4 MADE THAT SILENT, WHICH IS WHY IT LASTED.** A parse error becomes
`no_data`, becomes the static profile, becomes arbitrage off - the *correct*
degradation, and it says nothing whatsoever about the cause. A site would have
sat on the fallback indefinitely while the status page reported only that the
feed was down.
⚠️ **THE SUITE COULD NOT SEE IT BECAUSE EVERY FIXTURE WAS BUILT FROM THE
PARSER'S OWN ASSUMPTION.** `test_price.py`, `test_price_history.py` and
`test_static_tariff.py` each built `json.dumps({"data": [{"start": ...,
"price_eur_mwh": ...}]})` - a shape invented here, published by nobody. The
checks graded the parser against the parser's guess: a closed loop that cannot
notice the guess is wrong, and no amount of coverage inside it would have. The
loop is broken by **bytes nobody in this repository wrote**: two unmodified
response bodies are committed under `scenarios/`, one quarter-hourly
(2026-09-10, 96 points at 900 s) and one hourly (2025-09-10, 24 points at
3600 s - the same endpoint before Belgium's 15-minute MTU), with URL, retrieval
time, licence-as-returned and a sha256 recorded beside them in
`energy-charts-be-price-captures.json` and **re-derived** by the replay, so a
fixture edited to make a check pass stops being a capture. The remaining
invented fixtures are renamed `synthetic_row_feed` at every call site.
**The columnar document is read by its own function, `_points_from_columnar_json()`.**
Not by teaching the row parser to sniff for both: a parser that decides which
document it received is a parser that can decide wrong, and a wrong-but-
parseable response then becomes a price. Two shapes, two functions, and each
plugin names the one its feed publishes. Feeding the row shape to
`generic_dayahead` is now a graded `no_data`, so the sniff cannot come back
quietly.
⚠️ **UNEQUAL ARRAYS ARE REFUSED RATHER THAN ZIPPED.** `zip()` stops at the
shorter list and says nothing, so a truncated `price` array would have produced
a **real price series with its tail missing** - and the tail of a Belgian day is
the evening peak. That is worse than no series: `no_data` switches arbitrage
off, whereas a short series is traded on as though complete, and nothing
downstream can tell them apart. Refused in both directions, with the two lengths
in the reason.
⚠️ **A UNIT CHANGE IS REFUSED FOR A REASON `_validate_raw()` CANNOT COVER.** The
plugin converts with a fixed `0.001`; if the feed ever published EUR/kWh under
the same keys, every price would come out a **thousand times too small** and
`MAX_PLAUSIBLE_EUR_KWH` would not fire, because it only bounds prices that are
too large. DATA-02's fetcher already refused on this field; the shipped path
does now too.
**`unix_seconds` are UTC instants, said so explicitly**
(`datetime.fromtimestamp(t, timezone.utc)`); §9.3's rendering at the Brussels
offset stays where it already lived, in `assemble()`, rather than being copied
into the plugin where a mutation could not tell it from a no-op. A published
`null` is dropped and logged with a count - a missing quarter is not a free
quarter - while an all-null body is `no_data` named by this parser rather than
by the boundary validator.
**End to end against the live feed, 2026-09-10:** `resolve_tariff()` returns a
`TariffPlan` with `origin='provider'`, **96 quarter-hourly points**, spacing
`[900]` s and no decimation, first point `2026-09-10T00:00:00+02:00` at 0.30608
EUR/kWh all-in. FCST-04's H1 fix was never theoretical - 900 s is the shape of
the real feed.
⚠️ **WHAT THIS DOES NOT FIX.** `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy` are untouched: their URLs are unverified, no real body can be
captured for them, and withdrawing them is TARIFF-07's open decision. Their
fixtures are now named `synthetic_row_feed` so nothing reads them as evidence
that those feeds parse. And `generic_dayahead` still ignores `since`/`until`
and asks for no date range, so the default URL returns one published day - a
full 48 h horizon is reached only through §8.3's carry-forward fill.
### FCST-05 - what FCST-04's own contract still did not hold
**A single non-UTF-8 byte in `/data/price_history.json` stopped the add-on from
starting.** `_load()` caught `(json.JSONDecodeError, OSError)`.
`UnicodeDecodeError` is `ValueError -> UnicodeError -> UnicodeDecodeError` -
neither of those, and `issubclass(UnicodeDecodeError, OSError)` is **False** -
so it escaped `_load()` -> `_open()` -> `PriceHistory.__init__`, which
`Controller.__init__` does not guard. Reproduced: `UnicodeDecodeError: 'utf-8'
codec can't decode byte 0xff`, and **the controller did not come up**. That is the same class as the day-record defect the store was reworked
for, in the one byte class the rework left uncovered: valid-UTF-8-invalid-JSON,
a UTF-8 BOM and a non-dict day record all degraded correctly. The suite could
not see it because its "unreadable file" fixture writes `"{ this is not json"`,
which is **valid UTF-8**. The handler now names the `ValueError` family - the
file's CONTENT - beside `OSError`, the file's BYTES, and a fixture holding a
genuinely undecodable byte is in `test_price_history.py` section 5.
**A malformed `start` under the day the feed is writing to killed the tariff
plan permanently.** `_remember()` merged a day's points with
`{q["start"]: q ...}` and sorted on `q["start"]`, trusting a value read off
`/data` to be a hashable, sortable string. An `int`, `null`, a `dict` or a
`list` there raised `TypeError`; `run_tariff_refresh` catches `Exception`, so
the add-on stayed **up** while **every refresh raised, forever** - the plan
retiring after `TARIFF_MAX_AGE_S` and arbitrage and the cheap window off for
good, with no self-heal because `_remember()` raised before reaching `_save()`.
The read path (`_parse_points()`) was properly defensive throughout, which is
why `yesterday()` survived and the existing fixture passed: it files its
malformed rows under a day the feed is **not** writing to, so `_remember()`
never opened that record. **The two paths now share one validator**,
`_point_of()`, and neither has a standard of its own. A row that is not a point
is dropped and reported, and `_save()` rewrites the record clean.
⚠️ **AND THE STATUS ROW SAID THE STORE WAS HEALTHY WHILE THE PLAN WAS DEAD.**
`words` read `'2026-01-15 (1 h)'` about the record that was killing every
refresh. `_load()` now counts the rows inside a kept record as well as the
record itself, so the store stops reporting plain health from the moment it is
opened; the note names what was **found** at open and what was **dropped** by
the refresh, and clears itself once the file has been rewritten.
⚠️ **AND THE ROW COUNTED POINTS AND CALLED THEM HOURS.** `f"{d} ({_n_points(d)}
h)"` on the quarter-hourly feed this add-on already supports reads
`'2026-01-13 (96 h)'` for a 24-hour day - the same points/hours conflation the
sub-hourly defect above was about, on the row that defect's own card shipped.
The cell is now `2026-01-13 (96 points over 24 h)`: two facts, each under its
own unit, and the hour figure is the one that says whether tomorrow morning's
fill has a whole day to carry.
⚠️ **AND THE MERGE KEY IS THE INSTANT RATHER THAN ITS SPELLING**, which is what
rule 4 already said. Aware datetimes hash and compare by instant. The string
key merged by spelling, and the lexicographic sort beside it put the second
02:00 of the 25-hour October day (`+01:00`) **before** the first (`+02:00`);
only the stored order was affected, because `_parse_points()` re-sorts by
instant on the way out.
⚠️ **TWO STATED REASONS WERE FALSE, AND THIS REPOSITORY TREATS THAT AS A
DEFECT.** `price_forecast._audit()`'s "WHY IT IS STRICTER" section claimed the
rework refused two things FCST-03's audit did not. A differential over the
whole domain the audit can express - every published mask over 3 hours crossed
with every output series of length 0-3 - found **zero divergence in both
directions**: the reworked audit is exactly **EQUAL** to FCST-03's, not
stronger. The old `seen` count already refused the same published point emitted
twice (one point twice is one hour twice), and the old **identity** rule
already refused a carried point sharing a published hour. The only behavioural
change is the intended **relaxation** - several distinct published points in
one hour - and that stays. The docstring and the two check texts now say what
is true, and the differential is committed as a check in
`test_price_forecast.py` rather than left as prose.
⚠️ **AND `_audit` IS NOT WHAT STOPS THE DECIMATION DEFECT RECURRING.** It does
not check **completeness**: fed the decimation directly - four published points
in an hour, output emitting only the last - it **accepts**, and it accepts an
empty output. That is a limit, not a regression, and the module docstring said
otherwise by presenting the audit as the post-condition guarding provenance.
What actually guards it is the point **count** and the pass-through **identity**
checks in `test_price_forecast.py` and `test_price_history.py`, and the text now
points at them. It is **not** made complete: `published` is the whole read while
the fill emits only `[since, until)`, so "every published point appears" is not
a true post-condition of those two arguments. Measured - the rule as stated
takes the 1 h, 12 h and 48 h horizon checks red on legitimate series.
**No option was added, `config.yaml` is untouched, and nothing was deployed.**
**FCST-03 shipped the fill and no caller.** `price_forecast.fill_from_yesterday()`
was complete and checked, and so were the consumers written for it -
`TariffPlan.firm_points()`, `cheap_now()`'s refusal of a provisional hour, and
`arbitrage()`'s refusal 3, which drops provisional hours from the trade set
rather than refusing the whole series. Nothing in `app/` called the fill, so no
series ever contained a carried point and every one of those consumers was
exercising its all-firm branch.
⚠️ **THE DEFECT THAT PRODUCED WAS NOT AN ERROR ANYWHERE.** `load_prices()`
returns what the feed published and nothing widened it to the requested horizon,
so on a dynamic site between midnight and the 14-16 h CET day-ahead publication
the plan covered the rest of today and **nothing more** - typically 10-24 of the
48 hours `price_horizon_h` asked for. `arbitrage()` then took `max - min` over
that truncated window and reported a spread. The number was real, the window was
half the one configured, and **nothing said so**: tomorrow evening's peak, the
hour a morning charge would be sold into, was not in the series at all, so the
spread it would have created was never compared against anything.
**What changes:**
* `app/price_history.py` (new) keeps the **published** prices of the last few
Brussels days in `/data/price_history.json`, and `resolve_tariff()` now fills
an unpublished hour of the horizon from yesterday's same-wall-clock hour,
flagged provisional. ⚠️ **"An" unpublished hour, not "every" one:** the fill
can carry only an hour yesterday actually published, so a partial yesterday
leaves the local hours it never held **out of the series** - §11.4 for those
hours, and asking for one raises rather than answering. Correct behaviour,
and the wording is now the behaviour.
* ⚠️ **A sub-hourly feed keeps every print.** [⚠️ **The claim that follows is
FALSE and TARIFF-07 corrected it: `eneco_eddy` was not an imbalance product,
was not an Eneco product at all, and its endpoint never existed. The real
quarter-hourly feed is Belgian DAY-AHEAD since the 15-minute MTU of
2025-10-01, which is what `generic_dayahead` reads. The behaviour described
below is unchanged.**] `eneco_eddy` is the imbalance
product and settles per **quarter**; the fill walks whole hours to decide
what needs carrying, and that is not a rule about what a published hour may
contain. Every published point inside the horizon passes through by identity,
and a carried point is added only for a whole hour with no published coverage
at all. The first draft keyed the published set by hour - last point wins -
and a 96-point quarter-hourly feed reached the optimiser as 15 points with
its spread down from 0.143 to 0.014 EUR/kWh, on an all-firm, fully-published
series.
* The horizon is **whole hours at both ends**: `since` is floored to the hour
that contains it, and so is `until`. Asked for 48 hours at 08:17, the plan is
48 hours long and not 49.
* `resolve_tariff(history=...)` is **required and keyword-only**. A caller with
no durable volume passes the explicit `NoHistory()`. A default of `None`
meaning "skip the fill" would hand a caller who forgot the argument exactly
the truncated horizon this card removes, silently.
* A new status row, **Price history**, names the days held, how many points
each holds and how many whole hours they cover (see FCST-05: it shipped
counting points and printing them under the hour's name).
⚠️ **ONE CHANGE HERE MOVES ENERGY, AND IT IS NOT THE ONE THE CARD IS NAMED FOR.**
Carried hours are provisional, so §8.3 keeps them out of the trade set: the fill
widens what the optimiser can **see**, never what it may **do**. What does
change a trade is that the filled series is windowed to `[since, until)`, so
**hours that have already elapsed are no longer in the spread**. Before, a cheap
night that had already gone sat in the series as the day's cheapest hour - and a
cycle cannot buy in an hour that is past, so the trade was quietly never taken.
`test_price_history.py` section 2 grades this by finding the cheapest firm hour
with and without the fill and showing it **moves**.
⚠️ **A DEAD FEED IS STILL §11.4, NOT YESTERDAY.** The fill runs only on a
`series` read; a feed that published nothing still degrades to the configured
`static_profile`. The two are indistinguishable to the optimiser - both are
100 % provisional, so arbitrage refuses on the firm-pair rung and `cheap_now()`
is False - so preferring yesterday would change a documented degradation for a
difference only the status page can see.
`DECISIONS/FCST-04-the-day-that-is-carried.md` carries that and two more.
⚠️ **A BROKEN CACHE IS NOT A BROKEN CONTROLLER.** No `/data`, an unreadable
file, a schema this build does not know (including a `version` of `1.0`, which
`== 1`), a **day record that is not a record**, a malformed point - each its own
state with its own reason, none of them a price and none of them an empty
series. In every one the plan is still a real provider series and the controller
still regulates; the horizon is just as short as it was before this card.
`.words` never raises, because `Controller.__init__` reads it unguarded and a
status line that throws is an add-on that does not start.
⚠️ **AND WHERE THERE IS NO `/data`, NOTHING IS RECORDED AT ALL** - not even in
memory. An in-memory yesterday answers for one run and is gone on the next
restart, which is a cache that forgets without saying so; the honest pair is
`unavailable` on the status row and no prices carried.
⚠️ **"YESTERDAY" IS A LOCAL DATE, AND THE ARITHMETIC IS ON THE DATE.**
`brussels()` renders at a fixed offset, so subtracting `timedelta(days=1)` from
it subtracts 24 **absolute** hours - and the Brussels day before a
spring-forward is 23 hours long. Between 00:00 and 00:59 on the morning after
the March transition that lands on the day *before* yesterday. **No option was
added and `config.yaml` is untouched.**
## 0.9.0
⚠️ **MINOR FOR NEW FUNCTIONALITY, NOT FOR A BREAK - AND THAT DISTINCTION IS THE
POINT.** 0.8.0 was minor because a config that started on 0.7.0 could be
REFUSED on it (rule 10 against 0.7.0's own default `slew_w: 1000`). Nothing of
that kind is true here, and it was checked rather than assumed:
- `options:` and `schema:` both hold **71 top-level keys**, the same 71 as
0.8.0. The one schema addition is a per-entry key, `capacity_kwh:
float(0.1,200)?` - **note the trailing `?`, it is OPTIONAL**.
- An unmodified 0.8.0-era config validates clean on 0.9.0. Measured on both the
flat single-inverter shape the reference install runs and an N=2 roster with
no `capacity_kwh` on any entry: **0 problems each**.
- The two refusals [[OPT-09]] adds fire only on configs that USE the new key -
an unparseable value, or the key stated on one roster entry and left empty on
another. Neither can reach a config written before the key existed.
So: existing installs upgrade untouched, and the bump is minor because the
option surface and the behaviour grew.
Contents, in merge order since 0.8.0 (`06661c5`):
| | |
|---|---|
| `3d29993` | UX-02 - the validator's refusals, next to the field, before the save |
| `fdb3b69` | OPT-09 - the weights parameter nothing ever passed, and what it cannot do |
| `fcaa724` | PKG-09 - refuse a deploy that would be a no-op, or that the add-on would reject |
**UX-02** builds the real configuration surface in the ingress panel, beside the
Supervisor Configuration tab that cannot be removed. The prize is not styling:
`validate.py` writes long cross-field refusals the Supervisor UI *structurally
cannot show*, and until now an operator met them as **exit 78 in a log**, after
saving and restarting. ⚠️ Two config surfaces now exist and the DECISIONS record
names the **stored options blob** as authoritative, neither UI.
**OPT-09** makes the architecture's one free parameter real. `main.py` called
`resolve()` without weights, so the split was a fixed 50/50 regardless of what
either pack could deliver; it now passes SoC- and capacity-aware weights.
⚠️ **OPT-09 SHIPS A DISCLOSED DETECTION REGRESSION AT N=2.** `delivery.
delinquent()` reads an ABSOLUTE 500 W gap, so weighting a low-headroom unit down
to a small share puts a unit delivering **none of what it was asked** under the
threshold. Measured: a wedged inverter goes from named on 199 of 200 cycles to
**0 of 200** at a load its sibling can carry alone. The alarm returns once the
healthy pack saturates - swept, that is a 5000 W load on the fixture, **below**
the proportional-regime formula's 6500 W and not above it. ⚠️ **N=1 IS
UNAFFECTED**: `allocator.plan()` returns before weights are read at all.
⚠️ **CLOSED BY SAFETY-43 ON THIS BRANCH** - see its section below; the regression
above is history, and the record of it is kept because the measurement that
found it is what the fix is graded against.
**PKG-09** adds `tools/predeploy_check.py`. ⚠️ **RUN IT BEFORE DEPLOYING THIS
RELEASE** - it is what caught the fact that 0.8.0 had five runtime commits
behind it, which is why this section exists:
docker run --rm -v <repo>:/w:ro goodwe-addon-checks:1 \
python3 /w/goodwe_controller/tools/predeploy_check.py \
--deployed-version 0.8.0 --options /w/live-options.json
Exit `0` cleared, `1` REFUSED, `2` NOT CLEARED. ⚠️ **2 is not a pass.**
✅ **RUN AGAINST THIS RELEASE, 2026-09-07: CLEARED, exit 0.** The reference
install's options were exported from the Supervisor (70 keys) and checked twice
- the stored blob as-is, and the **effective post-upgrade config**, being those
70 keys merged over 0.9.0's 71 defaults. Both pass. `max_w` 5000, `slew_w` 400
against a rule-10 ceiling of 555.6 W.
⚠️ **THE STORED BLOB HAS 70 KEYS, NOT 71, AND THAT IS THE INTERESTING PART.**
`delivery_hold_s` arrived with SAFETY-42 in 0.8.0, so an install running 0.7.0
has never stored it - and it is REQUIRED in the schema, no trailing `?`, which
is the shape that becomes exit 78. It resolves to its `options:` default of
**185**, because the Supervisor sets `App.options = deepmerge(config.yaml
defaults, stored options)`; `tools/supervisor_selfapi_probe.py` §D pins that
against a real Supervisor image rather than assuming it. The second check above
exists because "your saved settings are valid" and "what the box will actually
run is valid" are different questions, and only the second one matters.
⚠️ **THE VERSION WENT UNBUMPED FOR THE THIRD TIME IN THREE DAYS** - PKG-06 six
merges, PKG-07 six, this one five - and this time it was caught by PKG-09's own
tool during PKG-09's review rather than by a person. `ha apps update` against an
unchanged version installs nothing and reports success. PKG-10 carries the
post-merge alarm so that noticing stops being a human's job.
## Unreleased
⚠️ **THIS HAS NO VERSION AND CANNOT REACH AN INSTALL UNTIL IT GETS ONE.**
PKG-06's and PKG-07's rule: the Supervisor keys the built image by `version:`,
so `ha apps update` is a silent no-op on an unbumped change. This branch
deliberately does **not** pick the number, because the right one depends on a
fact the branch cannot observe - whether 0.8.0's image has already been built
and pulled. If it has not, this belongs inside 0.8.0's section before it ships;
if it has, it needs 0.8.1. Whoever deploys decides, and PKG-07 is the record of
what happens when nobody does.
⚠️ **ANNOTATED BY PKG-14, 2026-09-16 - EVERY ROW BELOW HAS SHIPPED, AND THE
PARAGRAPH ABOVE IS NO LONGER TRUE OF ANY OF THEM.** It is annotated rather
than rewritten, and nothing is moved out of it, because re-filing this file's
misplaced entries is [[PKG-08]]'s card and guessing a boundary is what that
card exists to stop. What is measurable, and what PKG-14 measured:
* **UX-02 shipped in 0.9.0.** Its merge `3d29993` is an ancestor of the 0.9.0
bump `86bdf49` and it is already listed in `## 0.9.0`'s own contents table,
so this row is a duplicate of a released one.
* **UX-04, TEST-21 and SAFETY-43 shipped in 0.10.0.** All three merged after
`86bdf49`. TEST-21 (`app/delivery.py`, `config.yaml`, `translations/`) and
SAFETY-43 (`app/delivery.py`, `app/packshare.py`, `config.yaml`) are runtime
changes and are named in `## 0.10.0`'s preamble as shipping there and being
written down here; UX-04 touches no runtime file.
* ⚠️ **[[SAFETY-44]] also shipped in 0.10.0 and is nowhere in this file** -
`app/main.py` and `app/store.py`, three commits. It is named in
`## 0.10.0`'s preamble for the same reason.
| | |
|---|---|
| `3d29993` | UX-02 - a configuration page in the ingress panel, where the validator's refusals can be seen **⚠️ SHIPPED IN 0.9.0, see that section** |
| `bb46916` | UX-04 - UX-01's three unmet acceptance criteria: one withdrawn, one built, one re-attributed **⚠️ SHIPPED IN 0.10.0** |
| `6719bd8` | TEST-21 - `delivery_hold_s`'s floor re-derived from a harness that is now committed, and the recorded 30.0 s did not reproduce **⚠️ SHIPPED IN 0.10.0** |
| `37dd0f0` | SAFETY-43 - delinquency measured against the ask as well as against a flat 500 W, closing OPT-09's disclosed detection regression **⚠️ SHIPPED IN 0.10.0** |
⚠️ **SAFETY-43 CLOSES THE DETECTION REGRESSION OPT-09 DISCLOSED, AND IT IS A
TWO-INVERTER FIX. N=1 IS BYTE-IDENTICAL.** `delivery.delinquent()` named a unit
whose shortfall exceeded an **absolute** `min_w = saturation_w = 500 W`. OPT-09's
weights shrink a low-headroom unit's share, and shrinking the share shrinks the
gap - so a unit standing at +125 W and delivering **0 W**, 100 % delinquent, was
never named. It now names a unit whose gap exceeds `min_w` **OR** exceeds
`DELIVERY_SHARE_FRACTION` (0.85) of that unit's **own share**. Measured on the
same closed-loop fixture, same weights, same detector:
load 1500 W OPT-09 weights the old rule named on 0/200 cycles
load 1500 W OPT-09 weights the shipped one named on 200/200 cycles
⚠️ **`saturation_w` WAS NOT LOWERED, AND THAT IS THE POINT.** Lowering it would
report normal saturation as delinquency on every unit at once - SAFETY-41's
four-attempt false-trip regime, *"i'm getting really annoyed by the notifications
in my HA"*. This ADDS a second way to be named: all seven of `test_delivery.py`
part 1's existing fixtures answer identically under the old rule and the new one,
and the absolute arm's suppression window is still exactly 1000 W / 6500 W.
**0.85 is derived, not chosen.** `admin/goodwe:sim/delivery_window.py --campaign
--fractions` grades it over the SAME 2640 no-fault runs that produced
`delivery_hold_s`'s floor. The worst continuous legitimate episode is **35.0 s**
under the absolute arm alone (SAFETY-42 §3.3, reproduced in the same run) and
**40.0 s** at 0.85. ⚠️ **THE CURVE HAS NO CLIFF AND THAT IS THE FINDING**: swept
at twenty fractions from 0.05 to 0.99, everything from **0.45 to 0.99** is 40.0
or 45.0 s - within one control cycle of every other - and below 0.45 it rises
gradually to 90.0 s at 0.05. ⚠️ **"Zero false namings" is not achievable at any
fraction and the record says so**; what is zero is false ALARMS - the longest
legitimate episode in the whole sweep is 90.0 s against a 185 s hold, so nothing
comes within 95 s of notifying anybody at any fraction measured, and 145 s at the
shipped one. The N=1 control arm is 0.0 s at every fraction in all 2640
one-inverter runs, and the flapping family is 0.0 s in all 840.
⚠️ **[[CFG-07]] GETS ONE CONTROL CYCLE WORSE AND IS NOT FIXED HERE.**
`delivery_hold_s` is declared `int(30,900)` while the measured legitimate worst
was 35.0 s; it is now 40.0 s, so the band of schema-legal false-tripping values
widens from `[30, 35]` to `[30, 40]`. CFG-07 should be re-derived against 40.0 s.
⚠️ **IT MUST CLOSE BEFORE INVERTER B IS COMMISSIONED (~2026-09-12)**, not before
the next deploy: the band is UNREACHABLE at N=1 - `delinquent()` answers `{}` for
every input at a roster of one, so no `delivery_hold_s` can false-trip on the
install running today - and commissioning B is the moment it becomes reachable.
⚠️ **AND CFG-07 HAS NO DECISION DOCUMENT IN THIS TREE** - it exists as a card
reference here and in SAFETY-43's record and nowhere else, so whoever takes it
writes `DECISIONS/CFG-07-*.md` first.
**SAFETY-43 CHANGES NO OPTION VALUE, NO SCHEMA BOUND AND NO DEFAULT** - the
fraction is a derived constant with a committed harness behind it, deliberately
not a knob, for the reason there is no `delivery_w`. The one edit to
`config.yaml` is a COMMENT: the `delivery_hold_s` block described the check as
"short by more than `saturation_w`", which is now only half of it.
**No behaviour change at one inverter, asserted rather than argued**: `plan()` is
handed a `weights` mapping that raises if anything reads it and still answers
identically at a roster of one (and the same mapping raises at a roster of two,
so the tripwire is real), and `delinquent()` answers `{}` on all 84 single-unit
(share, measured, rule) combinations including 0 of 125 W.
`DECISIONS/SAFETY-43-delinquency-relative-to-the-ask.md` carries the curve, the
positive controls and the CFG-07 assessment.
⚠️ **TEST-21 CHANGES NO CODE AND NO OPTION. IT CHANGES A NUMBER THIS RECORD
CLAIMED.** `delivery_hold_s: 185` shipped resting on *"30.0 s, the worst
continuous legitimate episode at the shipped threshold across all 2640 runs"* -
from a harness `DECISIONS/SAFETY-42-unit-delivery.md` §1 deliberately did **not
commit**, because it imports `plantsim` and `frame_check` out of `admin/goodwe`.
A shipped safety constant the next reviewer cannot re-run is PROC-01's shape.
The harness is committed now, **in `admin/goodwe` as `sim/delivery_window.py`**,
beside `sitesim.py`. It is there and not here on purpose: those two modules are
that repo's, and restating them in this tree is the CI-08 coupling that has
broken three times. The dependency runs one way instead - this repo's `control`,
`arbiter` and the shipped `delivery.delinquent()` are imported live out of
whichever checkout is under test. Re-run it with:
```
cd goodwe/sim && GOODWE_ADDON_REPO=/path/to/goodwe-addon \
python3 -B delivery_window.py --selftest --campaign --blag
```
⚠️ **AND 30.0 s DID NOT REPRODUCE - IT IS 35.0 s.** Reported as measured rather
than adjusted to agree. What DID reproduce is the part the compatibility promise
rests on: the **N=1 control arm is 0.0 s at every threshold in every run**, and
the **flapping family is 0.0 s everywhere** in all 840 runs. What did not: the
headline (one control cycle worse), the reversal family (20.0 → 30.0 s), the
non-monotone curve (this rebuild's is monotone, so that finding is now an
argument and not a measurement), and the low-threshold rows, badly. The B-lag
rows moved the other way - a hypothetical unit four times slower than A gives
**75.0 s**, not 90.0 s - and they are relabelled throughout as a **sensitivity
study on a hypothesis about inverter B, which does not physically exist yet**,
rather than as a measurement of it.
**`delivery_hold_s` is NOT changed.** 185 s is 5.29× the re-measured worst
(was claimed 6.2×), 2.47× the four-times-slower case, 6.2× the firmware's
`LINK_STALE_S` veto and 4.9× inside the billing quarter: all four bounds still
clear and none narrowly. ⚠️ One consequence is worth an operator's attention:
at 35.0 s the rig's floor is now **above** the schema's own `int(30,900)`
minimum, so `delivery_hold_s: 30` is below a measured legitimate episode and
would report on ordinary saturation. The option is marked *derived, do not
change*; raising the schema floor is left to its own card.
⚠️ **UX-02 ADDS A SECOND PLACE TO CONFIGURE THIS ADD-ON, AND NO NEW WAY TO
COMMAND THE INVERTER.** The ingress panel gains a Configuration page beside
Home Assistant's Configuration tab. Both edit the same options blob; neither is
authoritative, the stored blob is. What the new one can do that the old one
structurally cannot is show `validate.py`'s CROSS-FIELD refusals - two inverters
naming one `setpoint_entity`, a `maintenance_charge_w` above `max_w`, a flat
`setpoint_entity` left set beside a roster - **next to the field, before saving**,
instead of as exit 78 in a log afterwards. The Supervisor's tab knows only types
and ranges and has no way to express a rule spanning two keys.
Four properties are the ones that could hurt somebody, and each is checked
rather than asserted (`test_selfconfig.py`):
* a blob the shipped validator refuses is **never written** - because an invalid
blob plus a restart is exit 78, and the panel goes down with the add-on;
* a blob that **changed underneath** the page is refused, not clobbered, and the
keys that moved are named. Two surfaces, one blob;
* **every message comes from the shipped validator.** Proven by inserting one
new rule into a COPY of `validate.py` and watching it arrive on the page with
every UI file byte-identical;
* **nothing on the surface commands an inverter or clears a latch.** Saving does
not even restart: applying options costs a control interruption - the
wind-down commands 0 W on every inverter - so that is a separate button that
says so first.
⚠️ **NO SCHEMA CHANGE AND NO CONTROL CHANGE.** `config.yaml` is not modified at
all by this card: the permissions the panel needs - `ingress: true`,
`ingress_port: 8099`, `hassio_api: true`, `homeassistant_api: true` - were
already declared, and the panel was already live.
`tools/supervisor_selfapi_probe.py` re-measures them against Supervisor
2026.08.0's own code, and found things the card had wrong: Supervisor's own
`/addons/self/options/validate` is **not** reachable from inside an add-on, and
the Configuration tab **can** be removed - at the cost of all 71 options, which
is why it stays. `DECISIONS/UX-02-two-config-surfaces.md` carries both.
⚠️ **UX-04 CHANGES NO BEHAVIOUR, NO SCHEMA AND NO DEFAULT.** It adds one check
file, three assertions to a probe, and a decisions record; `config.yaml`,
`translations/` and every module under `app/` are byte-identical to `6e7b233`.
It closes out [[UX-01]], which shipped in **0.7.0 and is live**, with three
criteria that were never met:
* **AC 3 - "the visible count drops to ~15" - is WITHDRAWN as unsatisfiable.**
`options:` and `schema:` declare the same 71 keys, so the set HA's *show
unused optional configuration options* toggle can hide is **empty**, and
Supervisor's own `UiOptions` marks **59 of the 71 required** - the frontend
shows those unconditionally, so 59 is the floor even with `options:` emptied
altogether. The target was ~4x below what any manifest can reach. ⚠️ And the
12 hides that *are* expressible would be bought with the deep-merge: a key
absent from `options:` has no default for the Supervisor to merge into a
0.7.0 box's stored blob, which is exactly the `delivery_hold_s` mechanism
that makes this release's upgrade safe rather than exit 78. The count was
**printed** by `tools/supervisor_shape_probe.py` §F from the day it was
written and never graded, which is how this passed review; it is now three
assertions, and removing one key from `options:` turns two of them red.
* **AC 4's third clause - the AST check for stray in-code literal fallbacks -
is BUILT**, as `test_defaults_pin.py`. It discovers the six
`*_OPTION_DEFAULTS` mirrors from the tree rather than naming them, grades all
30 mirrored keys against `config.yaml`, and freezes the CFG-03 backlog at
exactly today's **27 (module, key) pairs** so it can only shrink. It found
one previously unreported divergence: `main.py` answers a missing
`target_grid_w` with **0** where `config.yaml` ships **-10** - unreachable on
a Supervisor install, recorded rather than corrected. Its red direction runs
on every invocation, and a literal planted in the real tree was shown red.
* **AC 5 / the CFG-04 double-literal `max_w` hole is closed, by
[[UX-02]]'s `bcee235` and not by UX-01's `fef6ef2`.** Re-measured on this
branch: the `2000 -> 2500` triple mutation is **RED at `test_selfconfig.py`**,
where it survived 21/21 green on 0.7.0. The attribution is corrected in
`DECISIONS/UX-04-the-configuration-tab-and-the-defaults-pin.md`; nothing was
re-done.
The 8 per-entry `inverters:` translations **stay**. They are shipped, validated
and measured *not* to reach the Supervisor tab - `ha-selector-object` labels
those fields `fields[name].label || name` and the converter sets no `label` -
and UX-02's ingress panel is the surface that can render them. A written
decision, not a change.
## 0.8.0
⚠️ **A CONFIG THAT STARTED ON 0.7.0 CAN BE REFUSED ON 0.8.0, AND THAT IS WHY
THIS IS A MINOR BUMP.** [[SAFETY-39]] adds validator rule 10, which refuses an
explicit `slew_w` above `SLEW_RAIL_FRAC` x the site rail, where `SLEW_RAIL_FRAC`
is `LOOP_TICK_S / PLANT_SETTLE_S` = 2/18. On a 5000 W rail that ceiling is
**555.6 W**.
⚠️ **THE VALUE THAT BREAKS IS 0.7.0'S OWN SHIPPED DEFAULT.** `slew_w` defaulted
to **1000** and the schema was `int(50,5000)`; 1000 > 555.6, so an install that
never touched the key and simply took the default is refused on 0.8.0 until the
value is lowered. That is as backward-incompatible as it gets, and it is the
whole justification for MINOR over PATCH.
The schema also widens from `int(50,5000)` to `int(0,5000)`, and `slew_w: 0` -
**a value that was not legal before** - now means *follow the rail* and is the
shipped default. This is a new capability rather than a changed meaning.
⚠️ Refusal is `SystemExit(78)` (`EX_CONFIG`): the add-on does not start. **Read
the live options and check them against the ceiling BEFORE `ha apps update`.**
That check is NOT performed by this PR and cannot be - see the PR body.
CFG-04's rule and PKG-06's: the Supervisor keys the built image by `version:`,
so shipping a change without a bump means `ha apps update` is a silent no-op.
**Six merges accumulated behind an unbumped 0.7.0 before this was caught, for
the second time in two days.** The automated check that would catch it without
a human noticing is still unwritten, and that is PKG-06's standing follow-up.
Contents, in merge order since 0.7.0 (`bbc903b`). ⚠️ Each row carries the merge
subject's **whole** claim, including the half that is not flattering:
| | |
|---|---|
| `9e42cec` | CI-06 - `test_peakguard.py` answered two of its checks with the wall clock |
| `24c3d87` | SAFETY-38 - pin `site_standing` with shares that cannot answer for the site |
| `a4290d3` | SAFETY-39 - `slew_w` is a ratio to the rail, **and `gain` is the constant that is still wrong** |
| `c8dcb38` | SAFETY-37 - a stale reading is `None`, and arrival cannot be what says so |
| `0581648` | SAFETY-13 - the output freeze gets an exit, and only where it needs one |
| `464d398` | SAFETY-42 - a unit that stops delivering, **and the discriminator the card asked for does not exist** |
⚠️ **TWO DISCLOSED RESIDUALS SHIP IN THIS RELEASE.** SAFETY-13's bounded
freeze-exit shows 0 spurious releases on the sweep's measured-plant slice but
**2 of 272 on a finer grid**, and the docs carry the 2-of-272 figure rather than
the flattering one. SAFETY-42's card proposed a discriminator that **turned out
not to exist**, and the branch says so rather than shipping a weaker check under
the original name.
## 0.7.0
⚠️ **SCHEMA CHANGE, AND IT IS WHY THIS IS A MINOR BUMP RATHER THAN A PATCH.**
[[SAFETY-32]] adds `bms_soc_floor: int(0,50)` as a **required** per-entry key on
the `inverters` roster - no trailing `?`. A config that declares a roster and
omits it on any entry is REFUSED at startup. An install running `inverters: []`,
which is every single-inverter install including the reference one, is
unaffected: the flat `bms_soc_floor` still describes the one pack.
CFG-04 recorded the rule this follows - the Supervisor keys the built image by
`version:`, so a schema change without a bump is a schema nobody reads.
Contents, in merge order since 0.6.0 (`2d025ee`):
| | |
|---|---|
| `3934ad7` | MAINT-05 - one recalibration per pack, migration graded against the roster |
| `67e649a` | SPIKE-04a - inverter B and pack B recorded, from datasheet and serial |
| `3993f9f` | SAFETY-32 - per-pack `bms_soc_floor`, rule 8 per unit, package-wide roster pin |
| `f72c48d` | UX-01 - add-on configuration in English and Dutch |
| `86eaef2` | TEL-07 - a second MQTT device for inverter B; A's identity byte-identical |
| `4482cd8` | SAFETY-41 - the clamp alarm stops narrating normal anti-windup |
⚠️ **0.6.0 WAS NEVER SECTIONED.** Its content sits below this heading rather than
under one of its own, because the bump shipped without cutting the section. That
is a defect in this file, not in the release: the deployed 0.6.0 is `2d025ee` and
the table above is what is new since it. Splitting it retroactively would mean
guessing a boundary; saying so is more useful than a guess.
## Detail notes — accumulated, NOT a separate release
⚠️ **THIS HEADING USED TO SAY "Unreleased" AND IT WAS WRONG.** Everything below
has SHIPPED. The section accumulated across 0.6.0, 0.7.0 and 0.8.0 because each
release was cut without clearing it, so it names tickets from all three
([[SAFETY-18]] and [[SAFETY-30]] from the 0.6.0 era through [[SAFETY-42]] in
0.8.0). A reader who trusted the old heading would have concluded that shipped,
running behaviour was still pending — and there was a SECOND heading saying the
same thing further down, from the 0.4.x era.
Retitled rather than re-sorted, on purpose: splitting ~3000 lines by release is
real work that does not belong inside a version bump, where it would bury the
one line that changes what the Supervisor installs. Card PKG-08 carries it.
⚠️ **THE OUTPUT FREEZE NOW HAS AN EXIT, AND ONLY WHERE IT CANNOT END ON ITS OWN
([[SAFETY-13]]).** While the loop is frozen the command's magnitude may fall but
never rise; at `prev_w == 0` there is no magnitude left to fall, so a charge
cannot start. That refusal is deliberate - the inverter reporting power we did
not command means another writer is on the actuator, the §1.5 non-goal - and it
is kept. What it did not have was an END: nothing cleared it but the other
writer leaving.
The exit is now explicit, and *which* freezes get one is the decision rather
than *how long*:
- A divergence a **limit** could have produced - the inverter doing less than
the command, in the command's own direction - **clears itself**, because the
command is pinned at something the inverter can reach. It gets no exit, and
that is release/1.0's behaviour kept unchanged.
- A divergence a limit could **not** have produced - the inverter overshooting
the command, or producing the opposite sign - may not clear itself at all, so
it gets one. It releases once the divergence has outlasted the plant's own
measured settling time: `SETTLE_CYCLES` = **12** cycles at the measured tick.
⚠️ **THE BOUND COMES FROM THE SLOWER OF THE TWO DIRECTIONS THE PLANT WAS
MEASURED IN.** `NOTES.md` §5.10 timed the same 1.78 kW step both ways - ~18 s
up, ~23 s down - so `PLANT_SETTLE_DOWN_S` (23 s) joins `PLANT_SETTLE_S` (18 s)
as a named constant. SAFETY-39 uses 18 correctly, because its bound is a
*refusal* and the looser number refuses less; this bound asks how long the plant
may still be the *explanation*, and there the longer number is the safe one. A
bound of 9 derived from 18 fires the exit on a **single inverter with nothing
else on the bus** - measured in the container, 62 of 272 load-step pairs at the
plant's own measured shape, against 2 at 12.
⚠️ **`freeze-released` IS A PLACE TO START LOOKING, NOT A FINDING.** It says the
divergence outlasted the plant's measured settling time. It is **not** proof of
a second writer: a large load or PV swing can leave our own power coasting
outside our own command's interval, and a plant slower than the one that was
measured does the same. DOCS.md now gives the innocent causes first and the
second writer only when the state *stands*.
⚠️ **RELEASING THE OUTPUT FREEZE DOES NOT UNFREEZE THE LOOP.** The integrator
freeze is untouched, so the command can only walk, one slew step per cycle,
toward an accumulator that stopped accumulating when the freeze engaged.
Measured at the live install's shape (`max_w 5000`, `slew_w 400`,
`target_grid_w -10`) with another writer holding the pack at +700 W and 2 kW of
export standing: the command holds at 0 W, starts on the twelfth saturated
cycle and settles at **-1190 W** against a frozen integrator of -1194 W, not at
the 5000 W rail. On `release/1.0` @ `c8dcb38` the same run held **0.0 W on every
cycle**, for as long as the other writer stayed.
⚠️ **THIS IS NOT A REGRESSION FIX AND IT ESCALATES AT TWO INVERTERS.** The
unbounded block is `release/1.0` behaviour, confirmed cycle for cycle against
SAFETY-04's branch. At a roster of two, `actual_w` is the SITE SUM, so the
comparison is a site command against two units' power and one unit still moving
after the other has stopped can put the site into the block with no external
actor at all. ⚠️ That escalation is read from the code and from single-unit
runs; **it is not measured on two inverters.** Inverter B does not physically
exist yet and `sim/plantsim.py`'s `INVERTER_B` is `INVERTER_A` copied with
`measured=False`, so any two-inverter figure would be two copies of A.
Graded against `release/1.0` over the 3780-case sweep in `test_control.py`:
**3267 cases bit-identical, 432 releases, 27 of those change the command** -
every one a charge from `prev_w == 0` that `release/1.0` refused to start - and
**81 differ in the saturation counter alone**, because its ceiling moved with
the bound from 10 to 13. That ceiling change also removes a degenerate setting:
`config.yaml` accepts `saturation_cycles` up to 10, which is now strictly below
the release bound, so **no accepted configuration can stop the block engaging**.
At the old bound of 9 a setting of 9 or 10 deleted it silently.
⚠️ **THE SITE TARGET IS NO LONGER SPLIT 50/50 BETWEEN TWO PACKS ([[OPT-09]]) -
AND THIS ADDS A PER-ENTRY OPTION, SO IT IS A SCHEMA CHANGE.**
`capacity_kwh: float(0.1,200)?` joins the `inverters` roster as an **optional**
per-entry key. Optional, where SAFETY-32 made `bms_soc_floor` required, and for
that card's own reason: a missing cut-out would have to be *defaulted* and one
default for two batteries protects the shallower pack with the deeper pack's
number, whereas a missing capacity has an honest answer - no opinion about the
split, every unit weighs 1.0, which is exactly what shipped. It is **all or
nothing across the roster** and rule 9 refuses a partial one. There is no flat
`capacity_kwh`: at one inverter there is no split to weight.
The allocator has had a `weights` argument since [[ALLOC-01]] and **nothing had
ever passed one** - `main.py` called `resolve()` without it and `arbiter.py`
defaulted it to 1.0 per unit - so the split was fixed 50/50 regardless of what
either pack could do. Two things now feed it, and they are not the same kind of
thing:
- **an ENVELOPE, which is a permission.** A new `pack` UNIT claim at `P_SAFETY`
closes a unit's `hi` at 0 W when its own SoC is at or under its own
`bms_soc_floor`, and its `lo` at 0 W at 100 %. The allocator obeys it
absolutely, so an empty pack is not asked to discharge and its share moves to
the sibling. ⚠️ **Not filed at all at a roster of one** - every source routes
to the site there, so it would bound the SITE TARGET, and [[SAFETY-25]]'s
Option A (no loop-side SoC floor) stands untouched on the shipped install.
- **WEIGHTS, which are a preference.** Between those limits each pack is asked
for the fraction matching its **energy** headroom in kWh - not its power
rating. The two packs are asymmetric in opposite directions (5000 W /
15.36 kWh against 4600 W / 20.48 kWh **from datasheet**), so the two ways of
dividing hand the work to different packs.
⚠️ **AND WEIGHTS ARE A COMFORT CHOICE FOR STABILITY, NOT FOR DELIVERY.**
[[ARCH-01]]'s convex combination guarantees a bad split cannot destabilise the
site; it says nothing about whether the site can regulate. Measured (two 2000 W
units, one at its floor, modelled plant, real `compute()`): at a 3000 W load the
weighted arm and the shipped arm command the **identical** +2000 W into the empty
pack and deliver the **identical** 2000 W, because `_fill()`'s last-resort pass
hands the remainder to a zero-weighted unit rather than leave watts unplaced.
Closing the envelope does not recover those watts either - it reports them:
`unmet_w` becomes +2000 W and the action log says so, where before the record
read impeccable. A unit that cannot deliver still parks the site short by its
share, and that is now visible instead of silent.
Also: `arbitrage.decide()` is sized per pack rather than at the site rating on
both sides, so a two-pack site cannot ask to buy 9600 W with one pack able to
absorb it; and a 0 W sizing is refused by name, because a 0 W arbitrage claim is
a park order that outranks the loop. ⚠️ The sell side is a **no-op on every
roster today** - the sell gate reads the emptiest pack, so it refuses outright in
exactly the states where the sum could be smaller - and moving that gate is
deliberately not this card's; `DECISIONS/OPT-09-soc-aware-weights.md` §6 says
why.
⚠️ **[[SAFETY-42]]'s end-to-end fixture moved, and its finding did not.** That
card's evidence was that a wedged unit and a pack at its floor are byte-identical
in the power domain. After this card the cold pack is no longer *asked*, so the
shares differ - but the two quantities SAFETY-42's rejected discriminator reads
(saturation persistence and |grid error|) are still inseparable on both arms, so
the conclusion is unchanged and is now stated on the predicate's own inputs.
`test_delivery.py` part 4 carries the whole argument. The two cards meet at one
hazard from opposite sides: **OPT-09 stops the site ASKING a pack whose SoC says
it cannot deliver; SAFETY-42 alarms when a pack that said it could does not.**
⚠️ **AND THIS CARD NARROWS SAFETY-42's DETECTION WINDOW. IT IS A DETECTION
REGRESSION AT TWO INVERTERS AND IT IS DISCLOSED RATHER THAN FIXED.** An earlier
draft of this entry and of `DECISIONS/OPT-09-soc-aware-weights.md` §5 said a
wedged unit's weight does not move, so OPT-09 could not see the case at all. The
ENVELOPE half is true - a wedged box reads a healthy SoC and nothing closes. The
WEIGHT half was **false**: a weight is a function of a pack's ENERGY HEADROOM,
not of what the pack delivers, so a wedged unit's weight moves whenever its
headroom differs from its sibling's. And `delivery.delinquent()` names a unit
only while its shortfall exceeds `saturation_w` - **500 W in absolute watts** -
so shrinking the share shrinks the gap below the threshold and the alarm stops
firing. Measured end to end with the real loop, the real allocator and the real
detector, on a unit wedged at a healthy 15 % against its own 10 % floor (a
SAFETY-42 true positive by that card's own definition): at a 1500 W load the
healthy pack can carry alone, equal weights name it on **199 of 200** cycles and
these weights name it on **none of the 200** - shares 1505/125, gap 125 W, and
125 W is under the threshold. The suppression window widens from a site target
below 1000 W to a site target below `saturation_w * (w_A + w_B) / w_B`, which on
that fixture is **6500 W of a 9600 W site**; above it the healthy pack hits its
own rating, the allocator's last-resort pass hands the wedged unit a big share
again and the alarm returns. So in the quiet regime - where `unmet_w` is 0, the
meter is satisfied and no action-log line fires - **a wedged inverter with less
energy headroom than its sibling can now go unreported at ordinary house
loads.**
⚠️ BOTH BOUNDS ARE ARITHMETIC ABOUT `_fill()`'s PROPORTIONAL REGIME AND NEITHER IS A REACHABLE STEADY STATE. Swept on this fixture, the healthy pack's own 5000 W rating binds FIRST: suppressed 0/200 up to a 3000 W load, 4/200 at 4000 W, 41/200 at 4900 W (site target 5320 W, the largest reached with the wedged unit still under 500 W), then 195/200 at 5000 W once `_fill()` pins A at its cap and hands B 3000 W. So the alarm returns BELOW the 6500 W formula bound, not above it. The equal-weights 1000 W bound is unreachable for the same reason - the equal arm names the wedged unit 199/200 at every load swept, 1000 W included.
`test_packshare.py` part 8b grades it and pins the CURRENT behaviour, so
the day it changes a named check moves. Closing it means making `delinquent()`
relative to the ask rather than absolute, which is SAFETY-42's code and a design
change; that is filed as its own card and is deliberately not done here.
⚠️ Every two-unit figure above is **two copies of inverter A** through a modelled
plant - inverter B does not exist yet - and B's ratings are datasheet and serial.
⚠️ **AN INVERTER THAT STOPS DELIVERING ITS SHARE IS NOW REPORTED BY NAME
([[SAFETY-42]]) - AND THIS ADDS AN OPTION, SO IT IS A SCHEMA CHANGE.**
`delivery_hold_s: 185` joins `options:` and `schema:` (`int(30,900)`). The
Supervisor keys the built image by `version:`, so this needs a bump before it
ships - see the 0.7.0 heading above, which makes the same point about
`bms_soc_floor`. The key is ADDITIVE and defaulted, so an existing options blob
stays valid; what a missing bump costs is that nobody's Supervisor re-reads the
schema.
**Two or more inverters only, and at one inverter it is inert by construction.**
A unit standing at a discharge share it is not producing - short by more than
`saturation_w`, with nothing this add-on can read to explain it, while at least
one sibling is NOT in that state - is named after `delivery_hold_s`. That fault
was invisible to everything: the per-unit sign check needs OPPOSITION and a unit
at 0 W is not opposing but ABSENT, the site sum still agrees with the meter in
direction, circulating power is exactly zero when one unit does nothing, and the
only remaining trace is the saturation freeze - which `clamp.py` itself calls an
alarm operators learn to ignore. It is [[HW-01]]'s shape, which ran 6 h 25 m.
⚠️ **IT REPORTS. IT DOES NOT ACT.** Nothing is commanded differently, the loop is
untouched, `control.py` is not modified, and the site goes on running short by
that unit's share. Commanding an inverter that has stopped listening achieves
nothing (HW-01), and the only re-allocation this add-on can express is
all-or-nothing - measured on the rig, dropping a unit derated to 50 % from the
split leaves the site **400 W worse** than keeping it, and this detector cannot
tell that unit from a wedged one. The status row is a CAUTION, not a failure,
because the controller has not stopped.
⚠️ **THE CARD'S OWN DISCRIMINATOR WAS FALSIFIED, AND THAT IS THE MAIN CONTENT.**
SAFETY-42 asked for "saturation persisting past N while |grid error| > X, both
derived". Built and run on the two-master rig first, it fails in both
directions, and no (N, X) fixes either: a pack at its own floor and a wedged unit
are **identical on all 120 cycles** of a run in grid, site target, every share
and every measured watt - so the benign case fires - and with a sibling that has
headroom the standing grid error collapses to **30 W** while the wedged unit
stands at a +770 W share delivering nothing, so the real case does not. What
replaces it is a per-unit shortfall plus two reductions the card did not ask for:
an ACCOUNT (the pack's own `bms_soc_floor`, the only non-power fact that
separates an empty pack from a wedged one) and a PROPER SUBSET of the units asked
to discharge (which is what keeps a whole-site derate out, and what makes this
inert at N=1 - measured zero in all 1890 one-inverter runs).
The report **survives a Home Assistant restart** ([[SAFETY-34]]) under
`unit/<name>/delivery_tripped`, with one notification id per unit, re-raised on
the first cycle of every process and cleared by the same **Start** press as the
other latches. **Charge shares are deliberately not graded** - there is no
configured charge ceiling to explain a constant-voltage taper with, and arming
that direction would fire on every maintenance charge.
`DECISIONS/SAFETY-42-unit-delivery.md` carries the campaign (2640 healthy
two-inverter runs plus 1890 at one inverter as the control), the
inverter-B sensitivity sweep the margin is sized on, and the mutation ledger.
⚠️ **AND THE TWO THRESHOLDS IT READS ARE NOW GRADED AT A CONFIG THAT IS NOT THE
SHIPPED ONE.** `saturation_w` and each unit's `bms_soc_floor` are handed to this
check from the running config, and the promise that comes with that - raise
`saturation_w` and this check moves with you, there is no fourth copy of a
default to keep in step - is only true while the call site passes the
**configured** value. A literal equal to the shipped value keeps every fixture
green and removes the promise silently, and two such literals were survivors of
all 23 suites - measured, not argued - because no fixture that reaches this
check had ever run at a `saturation_w` other than the shipped 500 or at a
`bms_soc_floor` other than the shipped example's 10. Part 4b of
`test_delivery.py` now runs the same fault at a raised `saturation_w` and at two
cut-outs that bracket 10 from both sides, and each pair must answer two
different ways - so no constant passes. §9 of the decision record enumerates
every number this check reads and says which were already pinned this way and
which were not.
⚠️ **A PER-INVERTER POWER READING THAT HAS STOPPED FOLLOWING ITS OWN COMMAND IS
NOW `None`, NOT A HELD NUMBER ([[SAFETY-37]]).** `Inverter.batt` (register
`0x0518`) goes through a freshness gate: unchanged for >= 35 s *while* the
standing command is over 250 W *and* has travelled over 250 W since the reading
last moved. A stale reading is a **missing input**, which §11.1 rule 1 already
answers with 0 W and keeps commanding.
**This is a behaviour change at the shipped roster of one, and it is deliberate.**
Before it, a frozen power register read as a healthy measurement for ever - which
is [[HW-01]], where a value held for 6 h 25 m while the pack drained to its floor
and every detector read healthy. A healthy install is byte-identical: sixty reads
of a dithering register under a reversing command all reach the consumers
unchanged, asserted rather than assumed. A false verdict fails toward 0 W, behind
the existing `stale_input_s` hold, and clears itself the moment the register
reports a different value.
At two or more inverters it also removes two false alarms that had no gate at
all: [[SAFETY-30]]'s per-unit sign check no longer trips on a frozen reading
(measured: it trips without the gate and NEVER with it - the tick index is
deliberately not quoted, because it is counted on the wall clock inside
`cycle()` and is therefore load-dependent; the checkable statement is the
presence or absence of the trip, which part 3 grades), and
[[SAFETY-31]]'s circulating-power sensor reports `None` instead of a loop that is
not happening.
**No new configuration key, and no schema change.** The bound is derived from
`circulation_hold_s` and `unit_sign_disagree_*`, which the checks read out of
`config.yaml` at both ends - so moving either default takes the gate red rather
than leaving it silently too slow. `DECISIONS/SAFETY-37-freshness-policy.md`
carries the derivation, what [[TEL-06]] and [[TEL-08]] still owe, and three
named survivors - including the largest: **this detects a value that STOPPED, not
a value that is WRONG.**
⚠️ **`slew_w` IS A RATIO TO THE RAIL NOW, AND ITS DEFAULT CHANGED FROM 1000 TO 0
([[SAFETY-39]]).** `0` does not mean "off" and does not mean "unset" - it means
**follow `max_w`**, exactly as `integrator_max_w: 0` already does, and resolves
to `max_w / 9`: 222 W at the shipped 2000 W cap, 556 W at the live install's
5000, 1067 W at a ~9600 W two-inverter site. The 9 is
`PLANT_SETTLE_S / LOOP_TICK_S` - an 18 s measured step response against a 2 s
meter tick - so the loop takes the plant's own settling time to cross its whole
output range at any rail.
**An install that has never set `slew_w` will therefore command smaller steps
than it did on 0.7.0, and will converge more slowly after a large disturbance.**
That is the point rather than a side effect: `slew_w: 1000` was derived against
a **1500 W** clamp in 2026-08 and the live install has run it against 5000 since,
which crosses the whole range in 10 s against an 18 s plant. Measured on the
owner's system 2026-09-05: a 3.4 kW export drove the setpoint 380 -> 5000 W in
five ticks, the battery to -5154 W past a 5000 VA rating, and the grid from
3.4 kW of **export** to 2.8 kW of **import**.
An explicit `slew_w` is still accepted and is never silently reduced. What is
new is that a value **faster than the rail allows** is now **REFUSED AT STARTUP**
(`validate.py` rule 10), graded against the ROSTER SUM - so `slew_w: 1000` with
`max_w: 5000` will not start. Set it to `0`, or to any value at or below
`max_w / 9`. Slower is always accepted, including the interim 400 the reference
install has run since 2026-09-05.
⚠️ **This does NOT fix the over-absorption, and the record says so at length.**
Re-deriving the slew removes the >= 900 W setpoint step; the loop still absorbs
~1 kW more than the site needs on a large export step, because that is a `gain`
term and `gain: 0.6` was measured and deliberately left alone. See
`DECISIONS/SAFETY-39-slew-against-the-rail.md` §6, and do not read this entry as
more than it says.
**`test_peakguard.py` answered two of its own checks with the wall clock
(CI-06).** The file sits on the required `checks / unit (pull_request)` context
and had a measured ~20 % flake rate. It cost a wrong merge diagnosis (parents
green, merge red — read as a semantic merge conflict, it was the flake), a false
red on two reviewers' CONTROL runs, and a false "mutation caught" that reached a
merged card in four places. **A flaky check does not waste a re-run; it
manufactures evidence for whichever hypothesis the reader already holds.**
Both causes are the control law's own gain `900 / remaining` applied to a
wall-clock gap the file never intended to have. Neither fix widens anything.
* **The cross-time projection.** The "one cycle of the intent form is exactly
the delivered form plus the command standing on the wire" check decided the
intent form from a **second** `PeakTracker.project(..., datetime.now())` taken
after the real cycle had returned, and compared it against a floor decided
from the **first** projection — three lines under a comment saying both run
"against the same frozen projection". `excess = 900 × (projected − ceiling) /
remaining` moves at `excess / remaining` W/s, so at a 1500 W floor the 1.5 W
tolerance bought exactly **`remaining / 1000` seconds**: 333 ms with 880 s
left in the quarter, **6 ms with 10 s left**. The gap between the two
statements measured **12.7–39.5 ms** over 26 instrumented runs. The check was
decided by *where in the quarter it ran*. It now keeps the `Projection`
**object** the real cycle graded and decides both forms from it — the clock is
out of the comparison and the tolerance is **exact**, not widened. Measured on
a real cycle: re-deciding the delivered form from that object reproduces the
controller's own floor to **0.000000000000 W**.
* **The fixture's own room.** `wired_over_limit()` laid telegrams with
`range(0, span + 1, 5)`, leaving **0–5 s of the open block uncovered by
construction**, and `excess` multiplies an uncovered second back up by
`900 / remaining`. Measured on the shipped file: at **12 s of remaining a
fixture that asked for a 1500 W floor delivered 613 W (−59 %)**, and at 2 s
the guard **did not engage at all** — which fails "the real cycle files the
peak claim", "…and the number written to the inverter is the guard's floor"
and "the STATUS PAGE row for a floor-limited guard" **together**. The
four-attempt retry could not help: four attempts take ~40 ms and all land in
the same dying quarter. Fixed with one telegram stamped at `now` (what a real
meter does, and what the docstring already claimed) plus `FIXTURE_ROOM_S`,
**derived** from the 1 % accuracy the helper promises rather than picked:
`net_w × lag / (remaining × want) ≤ 0.01 − lag/900` → **23.6 s → 24 s**, at
the measured 0.1 s worst-case lag.
**Nothing was skipped, disabled or marked xfail** — the file still carries all
of SAFETY-07 and SAFETY-25's forced-discharge SoC floor, and it gains a check:
the delivered form re-decided from the cycle's own projection must reproduce the
real controller's number to the bit, which pins the test's `decide()` kwargs as
main.py's actual call rather than an approximation of it. **One tolerance got
stricter** (1.5 W → exact), because removing the clock made exactness possible.
**`site_standing` — the one quantity BOTH site guards are asked about — is now
pinned by a fixture whose per-unit shares cannot answer for it (SAFETY-38).**
`app/main.py`'s `site_standing = float(sum(standing.values()))` is the first
argument of [[SAFETY-30]]'s **latching, site-stopping** sign detector *and* the
`commanded_w` handed to [[SAFETY-18]]'s `looks_frozen()`. It was pinned by
**nothing**, and three mutations of it disarmed both guards with the whole suite
green. **This card changes coverage only: not one byte of `app/` moves — the
shipped `sum` is correct and must not be "fixed".**
* **⭐ THE FIXTURE THE SUITE COULD NOT BUILD: per-unit shares EACH BELOW the
site gate whose SUM clears it.** Two simulated units rated 220 W and 280 W,
both obeying exactly, inverted gain, house importing 2000 W — the site
commands **−500 W against a +2500 W meter** and no single share clears the
300 W gate. That is the case the site detector exists for, and it is the only
arrangement that can separate `sum` from the mean and from the largest share.
`test_watchdog.py` part 9a.
* **WHY THE EXISTING FIXTURE COULD NOT.** `_sign_site`, the suite's only N≥2
site fixture, runs shares of about −2500 W **each** — every one individually
over the gate — so sum, mean and largest-share all agree on it. *Its values
happen to be equal, and a check comparing two things that happen to be equal
cannot see the difference it names.* `MUTATION.md` habit 4, ninth instance,
inside the site half of the very card that names it.
* **FOUR CANDIDATE REDUCTIONS, FOUR DISTINCT ANSWERS, ONE OVER THE GATE** —
`sum` −500, mean −250, `max(key=abs)` −280, `[0]` −220 — and that is asserted
as a precondition, not described. The asymmetric ratings are load-bearing:
equal shares collapse three of the four onto one number, and the **smaller**
unit is first so `[0]` stays distinct from `max(key=abs)`. The **gate is the
shipped 300 W**; only the hold is shortened, because the hold is a wall clock.
* **⭐ THE SECOND CONSUMER IS COVERED, NOT SCOPED OUT.** The same value is
`looks_frozen()`'s `commanded_w` at `main.py:1926`. At the same roster the
site rail is 0.95 × 500 = **475 W**, so `sum` = 500 W rails it while 250, 280
and 220 do not. Shipped: the peak guard goes blind on SAFETY-18's conjunction
and files `floor_w = 0.0`. Under both surviving mutations it is **not blind at
all and files no floor**, so the battery may keep importing through a quarter
whose billed average is unobservable. `test_watchdog.py` part 9b. The open
quarter is deliberately backfilled with the stuck reading so the mutant cannot
reach the same action by the *coverage* route and mask the difference.
* **AT N=1 NOTHING CHANGES, AND IT IS ASSERTED.** On a real one-inverter
controller `standing` has one entry, so `sum`, the mean, `max(key=abs)` and
`[0]` are **the same number** — all three mutations are genuinely *equivalent*
on a shipped install and no N=1 fixture could ever separate them. Printed and
checked, beside the site detector still being absent there. Part 9c.
* **⚠️ A CORRECTION, AND IT IS THE MOST USEFUL LINE IN THIS CARD.** An earlier
revision of this entry said one of the three — `list(standing.values())[0]` —
was **already closed** by [[SAFETY-32]]'s package-wide structural pin, and
told future authors not to re-cover it. **That was false.** It had been
measured **once**, that run hit `test_peakguard.py`'s [[CI-06]] flake (a
measured **~20%** false-red rate), and the red was recorded as a mutation
**kill**. Re-measured on `release/1.0` @ `86eaef2` carrying only that edit:
the **full 21-file suite is green** and `test_peakguard.py` passes **five for
five** in isolation — **the mutation survives.** The reason SAFETY-32 cannot
see it is not the shape: part 12j taints names *bound* to roster values and
lists *accumulated* in a loop, and `standing` is a dict filled by **subscript
assignment**, so it never enters the taint set and `sum(standing.values())` is
not a roster site at all. 12j's own enumeration on the mutated tree lists
`main.py:1553`, `1555`, `1690` — **not `1599`**. **All three mutations needed
this card; all three are now covered by it.** *A single red from
`test_peakguard.py` proves nothing — re-run it five times in isolation and
name the failing check.*
* **⚠️ AND A ZERO-BYTE SURVIVOR ONE LINE BELOW THE ONE THIS CARD PINNED.**
Pinning the *value* `site_standing` said nothing about **where it goes**.
Swapping the detector's first two arguments —
`evaluate(site_standing, self.grid, …)` → `evaluate(self.grid, site_standing, …)`
— is **zero bytes** and left the tree fully green, because the check asserted
only that `"-500 W"` appeared **somewhere** in the banner. It still does:
**in the meter slot.** The swapped banner reads *"commanded +2500 W against a
meter reading −500 W"* — a site charging at −500 W into a +2500 W import, told
to the operator **exactly backwards**, on the one line somebody woken by a
latching site-stopping alarm reads first. The check now asserts the **ordered
pair** rather than a substring, and is red on it. **No `app/` change:** the
hole was in the test.
* **⭐ A SURVIVOR THIS CARD WENT LOOKING FOR AND CLOSED.**
`site_standing = float(self.target)` — the arbiter's site *target* instead of
the sum of what actually **stands on the wire** — is **−11 bytes** and
survived the full suite, because in every fixture that existed the two are the
same number. They are not when a device's reported range is narrower than its
`max_w`: the `device` claim is filed **per actuator**, so it bounds each
unit's share and never the site target. A site asking for −500 W while −250 W
stands would then take a **latching site-wide false trip** under its own
300 W gate. Closed by part 9a's device-clamped counterfactual.
* **⚠️ AND THE SAME ZERO-BYTE DEFECT ONE CALL SITE OVER — THE ONE A SHIPPED
INSTALL CAN ACTUALLY SEE.** The ordered pair went onto `main.py:1620`, the
**site** detector. That detector is armed only at N≥2, and part 9c asserts it
is **absent at a roster of one** — so on every install this add-on has, the
**per-unit** banner is the only sign-disagreement sentence that can ever be
printed, and its call at **`main.py:1560`** was still unpinned. The identical
swap there is **0 bytes** and left the tree **21/21 green**, and nothing
behavioural could ever have caught it: `disagrees()` is **symmetric** in those
two arguments (`commanded_w * against_w < 0`, `abs()` gate on both), so the
mutant takes **identical actions on every input**. What moves is the sentence
— measured, **9 emitted banner lines invert in 3 distinct sentences**,
including the one persisted to `sign_reason` and read back after a restart:
*"commanded +1000 W against its own measured power −1000 W"* becomes
*"commanded −1000 W against its own measured power +1000 W"*. Closed by the
ordered pair on **both** per-unit banners — the N≥2 `its own measured power`
one and the **N=1** `a meter reading` one — with both operands read off the
**observed cycle** rather than off the arguments the detector was handed, plus
a precondition on each that the two operands really are different and opposite
in sign. **Red on four named checks, green in the other twenty files. No
`app/` change.**
* **⭐ AND THE FAMILY IS NOW ENUMERATED BY MACHINE, because it had been
enumerated by hand twice and was short both times.**
`tools/symmetric_message_scan.py` finds every call whose argument order is
load-bearing for a **message** rather than for a decision: it renames each
parameter pair, erases every formatted string, canonicalises the commutative
operators and iterates to a **fixpoint** (the symmetry is usually one call
deep — `evaluate()` is symmetric only *through* `disagrees()`), then
classifies each sentence by where it goes. A second census covers sentences
the **caller** builds. It found **one open survivor this card does not close
and now discloses** — `rail_unreachable()`'s `dev_min`/`dev_max` at
`main.py:3208`, **0 bytes, 21/21 green**, a status-page row — and **twelve**
unpinned caller-built sentences including SAFETY-31's `circ_reason`, which is
the same shape and is also persisted. The list, the pinned status of every
member and the instrument's own blind spots are in
`DECISIONS/SAFETY-38-site-standing-pin.md` §7.
* **⚠️ AND A LEDGER SENTENCE THIS CARD ITSELF GOT WRONG, CORRECTED WITH THE
MEASUREMENT.** An earlier revision said *"before part 9 existed, **three** of
these left the whole suite green — M1, M2 and M3 — and the remaining seven
were caught by SAFETY-30's own N≥2 checks"*. **Eight** did. Re-run one at a
time on clean `release/1.0` @ `bbc903b`, fresh copy each, bytecode purged,
byte delta and `main.py` fingerprint printed, **full 21-file suite** every
time: M1, M2, M3, M4, M7, M8, M9 and M10 are all **21/21 PASS**; only M5 and
M6 go red. It is the same species of error this round exists to fix — **a
survivor recorded as a kill** — and the file contradicted itself three times
while saying it. **And the two that ARE caught make the card's case:** M5
(`sum(abs …)`) and M6 (`-sum`) are the only two that reverse the **sign**.
Every other entry changes only the **magnitude**, and the old `_sign_site`
fixture's ~−2500 W shares put nine different magnitudes on the **same side of
the same 320 W gate**. The pre-existing coverage could see a sign and nothing
else.
* **13 mutations — 11 of that line and its call site, plus 2 zero-byte edits to
the arbiter claim wiring — each on a fresh full-repo copy mounted `:ro`,
bytecode purged by `tools/mutation_run.sh`, the edit re-read from disk and the
byte delta printed. All 13 red.** Every one was **re-run independently** in
this round rather than carried forward from the previous round's report. The
claim-wiring pair (`sign_site` and `circulation` moved from site scope to unit
scope) closes two gaps a reviewer disclosed — though **`circulation`'s kill
belongs entirely to pre-existing checks and is not claimed by this card.**
⚠️ One **false red** from `test_peakguard.py` on M10 did not reproduce in four
subsequent runs; it is CI-06's known flakiness, no claim here rests on it, and
it is recorded rather than quietly dropped — unlike the one that *was*
believed, two bullets up. Ledger, and an **enumerated list of what was not
mutated**, in `DECISIONS/SAFETY-38-site-standing-pin.md` §4a, §4b and §6a.
* **⭐ ROUND 4: THE SCANNER COVERED ONE SYNTACTIC SINK AND CALLED IT THE
FAMILY, AND TWO LIVE MEMBERS WERE SITTING IN THE HOLE.** Every one of census
B's 16 members was a sentence that is **appended, assigned, or logged**. Not
one was **RETURNED** — and census A's return bucket only ever held a callee
formatting its own *parameters*, so a method formatting its own **attributes**
and handing the string back was invisible to both. That is the whole
`describe()` / `explain()` family, which is where this codebase keeps its
operator sentences. **Worse than the gap: it was in none of the five blind
spots the tool printed about itself.** The tool now scans the return sink
(census C), resolving it through the returning method's **call sites** so that
a returned *key* — `store.unit_key()`, `mqtt.unit_state_key()` — is not
mistaken for a returned *sentence*; it also scores a sentence handed to a
constructor as `reason=` or placed under a `"text"` dict key, which added
**six more caller-built members** it had been stepping past. Re-run, it
**rediscovered both of the members this round was sent to fix without being
told where to look**.
* **⭐ `ClampResult.describe()` — the clamp alarm the owner has been complaining
about all day — had a SECOND independent way to lie, and no `test_*.py`
mentioned `describe()` at all.** Transposing `requested_w` and `applied_w` in
`clamp.py:253` is a **zero-byte** edit that leaves the guard reporting a
setpoint clamped **UPWARD**, in the measured case to +9999 W by a bound whose
rating the same sentence gives as 2000 W. It is the §15 action-log row
(`main.py:1366`) **and** the ClampWatchdog notification reason
(`main.py:2452`). Measured **21/21 green** before; now **red on 4 checks** in
`test_clamp.py` part 6d, pinned on the **ordered pair** on the contiguous
literal at **both** consumers, with operands read off `ctl.target` and
`hass.writes[-1]` — what the loop asked and what the device was sent — rather
than off the `ClampResult` the swap lives in.
* **⭐ `PeakDecision.explain()` — the status-page banner — the same shape.**
`projected_w` ↔ `ceiling_w` at `peakguard.py:493`, **zero bytes**, and the
row then reads *"quarter projects 5013 W under a 2300 W ceiling"*: a quarter
**2713 W over** its ceiling, on a row whose own words say *idle* and whose own
flag says **ok**. `"peak guard idle"` appeared in no `test_*.py`. Measured
**21/21 green** before; now **red on 3 checks** in `test_peakguard.py` part 13,
pinned on the decision and on the shipped status row at `main.py:3313`.
⚠️ **A correction the ticket is owed:** the idle sentence does not reach
`main.py:3299/3302` — those are the *floor-limited* branch, where `explain()`
returns `self.reason` before the idle literal is built. It reaches
**`main.py:3313`** and, on the release edge, `main.py:1951`.
* **`test_arbiter.py`'s scope-violation check made a claim WIDER than its
assertion** — it said `scope_violations` *"names the source and the actuator
it does not belong on"* and asserted `"peak" in scope_errors[0]`, which is
still true after the two swap roles. Measured this round: **0 bytes, 21/21
green**; now red on 2 checks, pinned on the ordered pair.
* **14 more zero-byte mutations measured, and 10 SURVIVORS ARE DISCLOSED RATHER
THAN CLOSED**, each with its file fingerprint and its 21/21 verdict, in
`DECISIONS/SAFETY-38-site-standing-pin.md` §7e–§7g: **two** in
`allocator.py`'s `UnitPlan.explain()`, three across `arbiter.py`'s two
`explain()`s, two in `tariff.py`, two in `arbitrage.py`'s trade reasons and
one in `main.py`'s SoC-floor notification. The other four of the fourteen are
kills: `allocator.py:162` was already caught by `test_alloc.py`, and
`clamp.py:253`, `peakguard.py:493` and `arbiter.py:264` are closed here. **An enumerated list with honest
gaps beats a fifth round finding a fifth instance.**
⚠️ **And the probe that grades those mutations was itself the defect, once.**
Its first cut numbered the operands **by order of appearance**, so after a
transposition the other leaf took the same number and all thirteen renders came
back **byte-identical** — which reads exactly like *the edit is inert*. Keying
the value to the **name** fixed it. A measurement comparing the swap against
itself, in the instrument this time.
* **The tool now states what it does NOT scan**, largest hole first:
`%s`-style lazy logging (`_LOG.error("… %s … %s", a, b)` puts the operands in
*arguments*, so no census here looks at them and the transposition is the same
zero-byte edit — **31 such calls across 8 modules, counted and listed by the
tool rather than asserted**), `.format()`/`%`/`+`/`.join()` sentences, a sentence that
leaves through a dict or dataclass and is rendered elsewhere, `yield`ed
sentences, message attributes outside the `reason`-shaped set, and everything
outside `app/`. Its five over/under-report gaps stay, and every census row now
prints whether the two interpolations **share a format spec** — the difference
between a transposition that is silent and one that merely looks broken.
**Inverter B gets its own MQTT device, and inverter A keeps the one it has
(TEL-07).** MQTT discovery announced **one** device, and every entity hung off
one `unique_id` prefix, so at two inverters B's per-unit telemetry had nowhere
to go. It has one now — **without touching a single entity that already
exists.**
* **⭐ A's discovery payloads are byte-identical to `release/1.0`.** Same topics,
same `unique_id`s, same payload bytes, same retain flags, in the same order —
verified by **diffing the announced payloads**, not by reading the code:
`9 topics, 0 missing, 0 changed, 0 added` at a roster of one, and
`0 missing, 0 changed, 8 added` at a roster of two. That is what protects the
live install's recorded history and the three watchdog automations that name
its entities.
* **⚠️ THE ASYMMETRY IS DELIBERATE — DO NOT "CLEAN IT UP".** The first roster
entry's per-unit rows go on **the device it already has**; every later entry
gets its **own** device (`via_device` the controller). "One device per
inverter" is tidier and is the change that renames every entity on the live
system — and because HA keeps the id it composed at first discovery, a rename
produces a **new entity beside a dead one**: the history stays behind and
every dashboard, template and automation goes on pointing at a sensor that
quietly stopped updating. The composed ids come out symmetric anyway
(`sensor.goodwe_inverter_a_battery_power` /
`sensor.goodwe_inverter_b_battery_power`).
* **Four per-unit rows** — setpoint, battery power, SoC and the SAFETY-02 sign
latch — announced **only from a roster of two**. At N=1 nothing is announced
and nothing is published: no second device, no renamed entity, no added topic,
asserted rather than assumed.
* **Site-scoped sensors stay site-scoped.** `grid` and `p1_sample_age_s` are
announced **once**, on A's device, at every roster length 1–6. There is one P1
and one grid connection, and `p1_sample_age_s` is a **watchdog input** — a
second copy is a second answer to "is the meter fresh?", one of which is
always the one nobody is looking at. Circulating power, controller status,
maintenance phase and the capacity-tariff peak are site for the same reason.
* **`inverter.roster_names()`** is now the one answer to "what are the units
called", read by `build_roster()` **and** by the publisher — which has to know
the roster **before** a `Controller` exists, because announcing happens on the
broker's CONNACK.
* **`test_mqtt.py`**, a new suite: the recorded `release/1.0` baseline
(generated by running that commit's module, not transcribed), the payload
diffs, the composed entity ids modelled **independently** of `app/mqtt.py` and
anchored on the one id verified against the live system
(`sensor.goodwe_p1_sample_age`), the announcement-vs-publication agreement on
a real `Controller` with **different** SoC, battery sign and latch state on
the two units, and **twelve mutations of the shipped module, all red, each on
a named property**.
* **MEASURED, NOT ASSERTED.** Three of those properties exist because the
mutation table found their absence: dropping the unit from the *state topic*,
moving `grid` into the per-unit set, and `units=()` in main()'s publisher call
were all **green** on the first run. So was a roster fallback that named two
nameless entries `inverter-a`. Sixteen mutations were run through
`tools/mutation_run.sh`; the survivors are enumerated **with their size** in
`test_mqtt.py` part 9.
* ⚠️ **Inverter B does not physically exist** (~2026-09-12). Every fixture here
is **simulated**, from the datasheet and serial in `NOTES.md` §1.1b. Nothing
in this card was measured on a second inverter.
**The add-on configuration screen now speaks English and Dutch instead of raw
option keys (UX-01).** There was no `translations/` directory at all, so Home
Assistant fell back to rendering the option KEYS — an operator opening
*Configuration* read `unit_sign_disagree_w`, `saturation_cycles`,
`integrator_max_w`, seventy of them, in file order, with no description and no
way to tell a constant derived from 1890 closed-loop test runs from their own
inverter's rating. **This card changes presentation only: not one default, not
one range and not one line of behaviour moved.**
* **`translations/en.yaml` and `translations/nl.yaml`**, with a `name` and a
`description` for **all 70 options** and for **all 7 per-entry keys** of the
`inverters:` repeatable section. The Dutch is written for a Flemish
homeowner rather than transliterated: *afname* and *injectie*, *kwartierpiek*
and *capaciteitstarief*, *laadniveau*, *uitschakelgrens* — the words that are
on the bill and on the meter.
* **⭐ EVERY DERIVED CONSTANT SAYS WHERE IT CAME FROM AND WHETHER TO TOUCH IT.**
`unit_sign_disagree_s` now reads *"derived from 1890 closed-loop test runs
(SAFETY-30): 85 s is 8.5 times the worst legitimate opposition those runs
produce… do not change it without re-deriving"*; `circulation_w` cites its 924
runs and the measured 400 W knee; `meter_freeze_s` cites the 2399 s capture;
`bms_soc_floor` says it is register `0x0560` read off the pack. The two
numbers that are genuinely the operator's — `max_w` and `peak_cap_w` — say
**"THIS IS YOUR NUMBER"** instead, and `cycle_cost_threshold_eur`, which is
neither measured nor the operator's, admits it is an open product question
(OPT-08) rather than borrowing the others' authority.
* **`config.yaml` reordered into task order** — hardware/entities → meter →
ratings and limits → tariff → maintenance → safety → advanced — in **both**
halves, with every comment carried with its key. ⚠️ The rendered order is the
**`schema:`** half's (`App.schema_ui` is `UiOptions(...)(data["schema"])`);
the `options:` half is reordered to match so the file reads the way the tab
renders. ⚠️ **`test_inverter.py` part 12's first-match trap is preserved**:
the nested per-entry `max_w:` still appears BEFORE the flat one under
`schema:`, and `inverters: []` still ships in the `options:` half. Moving the
nested block below the flat one is a **1-byte** edit and it was run: red in
`test_inverter.py` and in `test_translations.py`.
* **MEASURED, NOT ASSERTED.** `tools/supervisor_shape_probe.py` gains a section
F that loads both files with Supervisor 2026.08.0's *own*
`_read_app_translations()` out of the release image (a file that fails
`SCHEMA_APP_TRANSLATIONS` is **dropped with a log warning and nothing else**),
runs its own `UiOptions`, replays the frontend's label resolution transcribed
from the shipped bundle, and prints every rendered row in both languages.
* **⚠️ ONE MEASURED NEGATIVE RESULT, RECORDED RATHER THAN GLOSSED.** The
per-entry keys inside the `inverters:` repeatable section still render RAW.
`_convertSchemaElement` sends `type: "schema"` **with** `multiple` to
`ha-selector-object`, which labels its fields `fields[name].label || name`,
and the converter sets neither `label` nor `translation_key`. The `fields:`
translations are shipped and validated because that is the shape Supervisor's
own schema defines for exactly this, and a frontend that wires `label` through
would consume them — but on 20250925.1 they do not reach the screen, and this
card does not claim they do. The `inverters` label and description themselves
do.
* **A new check, `test_translations.py`, so this cannot rot.** A translation key
naming an option that does not exist, or an option with no translation, fails
CI — in both directions, for both languages, top-level and per-entry. It is
**mutation-tested both ways**: eleven mutations applied in-process, each
required to NAME the key it broke rather than merely to go red, plus a
negative control that the unmutated input is clean. Two of the eleven are the
ones that cost the WHOLE FILE rather than one label — an unrecognised
top-level block, and a `network:` value that is not a string. Supervisor
validates each translation file through `SCHEMA_APP_TRANSLATIONS` and, on
refusal, **logs a warning and drops all of it**, so those silently return the
entire tab to raw keys; neither is reachable through the `configuration:`
coverage, which is why they were hunted for and closed. Six more were run **on disk**, through the
purge-and-re-read protocol: deleting a translation (−65 B), renaming an option
in `config.yaml` (+4 B), adding an orphan key (+47 B), emptying a Dutch
description (−711 B), breaking one label's group prefix (−4 B) and deleting a
provenance citation (−19 B) each go red.
* **The parser has a licence.** There is no PyYAML in the add-on's CI image, so
`tools/translations_lint.py` reads these files by hand — and a hand parser
that quietly disagrees with the real loader is the defect this repository
keeps finding. The probe imports **that same module** and asserts, key by key
and string by string, that it returns what `_read_app_translations()` returns.
The parser is deliberately strict and **raises** on anything outside the
subset; nine malformed shapes are fed to it to prove it does.
* **⚠️ WHAT THIS CHECK CANNOT SEE, stated with its size.** It grades coverage
and provenance *citations*, not truth. Falsifying a figure inside a
description that is not one of the cited tokens survives (run: *"8.5 times"* →
*"3 times"*, −2 B, green), and swapping two options' descriptions survives
(0 B, green). Separately and out of this card's scope: changing a shipped
default that no suite pins survives — `step_w: 10` → `20` (0 B) leaves
`test_control.py`, `test_clamp.py`, `test_validate.py` and
`test_peakguard.py` green. That is the same family as CFG-04's DEFECT 2 and
the UX-01 rescope moved it to its own card on purpose.
**Inverter B's rating is 4600 W, FROM ITS DATASHEET, and every documented copy
of it now says so (SPIKE-04a).** Three places stated B's rating — `config.yaml`'s
commented roster example, `DOCS.md`'s, and `tools/supervisor_shape_probe.py`'s
"a blob an operator would POST" — and all three said **3000 W**, a number that
was never measured, never read off a datasheet, and simply wrong. The owner
supplied B's model and serial on 2026-09-04: a **GoodWe GW5048D-ES**, serial
`55048ESU22AW0992`, max charging and discharging power **4600 W**. No control
behaviour changes here; this is documentation and its pin.
* **Serial characters 6-8 read `ESU`** → platform 105, AA55, the supported set.
Not `ESN`/`ESC` (ES G2, platform 745). SPIKE-01 does not gate this site.
⚠️ A passed platform gate is **not** a proven control surface: `specs.md`
already calls other platform-105 serials *"same protocol family; untested
silicon"*, and this repo's `0x056E`/`0x056F` map was reverse-engineered from a
passive tap on **one BPS unit**. That check is the bench half of SPIKE-04.
* **⚠️ 4600 W IS FROM A DATASHEET AND IS NOT A MEASUREMENT, and one ambiguity is
recorded rather than guessed.** The datasheet prints it under *Battery Input
Data*, so it is probably **DC**, while `max_w` is graded against `0x0518` —
the inverter's own **AC** power. If it is DC the AC ceiling is nearer
4600 × 0.94 ≈ **4324 W**, and the charge direction moves the other way
(≈ 4894 W drawn AC-side). **Neither reading is written in as fact.**
SAFETY-20's `min(max_w, dev_max)` already bounds it correctly under either,
once `dev_max` is read off the unit — so `max_w: 4600` is what to configure
today. `goodwe/NOTES.md` §1.1b carries the full record, with the date and the
method on every figure.
* **A NEW CHECK, BECAUSE A DOCUMENTATION FIX WITHOUT ONE DRIFTS AGAIN.**
`test_validate.py` now pins all three documented rosters: they must be
findable, they must agree, and they must say **4600**. It also grades the
**provenance beside the number** — the datasheet it came from, the `0x0518`
it is graded against, and the 4324 W the DC reading would make it — **within
2500 characters of the roster, not file-wide.** The first version searched
whole files and was already vacuous on two of them, because `0x0518` appeared
in `config.yaml` and `DOCS.md` for unrelated reasons before this card: a
check whose data could not reach the failure it named, in the file that
exists to complain about those. Four mutations were run against the fixed
version — the probe back to 3000 (0-byte delta), the `DOCS.md` caveat
deleted, `config.yaml` alone "corrected" to 4324 (0-byte delta), and the
probe's entity renamed so the regex finds nothing — and all four are red.
* **THE TEST FIXTURES KEEP 3000 W ON PURPOSE, AND NOW SAY WHY AT THE LINE.**
`test_inverter.py`, `test_maintenance.py`, `test_peakguard.py` and
`test_watchdog.py` build a second inverter at 3000 W against A's 5000 W. The
only property those checks consume is that B's number is **unmistakably** not
A's, and the real pair is a **400 W** gap — narrower than `slew_w`, inside the
range where an off-by-one-unit bug and ordinary control arithmetic produce
indistinguishable numbers. Collapsing them onto the real values would buy
realism those checks do not use and cost them their separating power, which
is the defect `test_peakguard.py`'s own §10g precondition exists to prevent.
They are **illustrative, not B's rating, and no longer a placeholder for it**.
* **Two consequences with numbers, recorded in `goodwe/NOTES.md` §1.1b for the
cards that own them.** At 94 % battery-to-AC a round trip is ≈ 88 %, so A
charging 3 kW while B discharges 3 kW burns ≈ **360 W continuously** with the
meter at zero — SAFETY-31 argues its threshold from *"a few watts"* and has no
figure. And **< 13 W night self-consumption per unit** (≈ 26 W for two,
≈ 0.6 kWh/day), which nothing in this add-on accounts for anywhere.
* **The site is asymmetric in opposite directions:** A = 5000 W / 15.36 kWh
nominal, B = 4600 W / 20.48 kWh — ~33 % more energy, ~8 % less power. No
stability implication (ARCH-01's ḡ = Σαᵢgᵢ is a convex combination), but a
full recalibration of B moves 33 % more energy and **MAINT-05's 12 h `drain`
phase timeout was derived on A**; it should be re-checked against B rather
than assumed to carry.
**Every pack is recalibrated on its own schedule, and only one moves power at a
time (MAINT-05).** §12's monthly cycle drains a pack to empty and refills it to
true its coulomb counter. There was exactly one `Maintenance` state machine and
one un-namespaced history, so at two packs **only the first was ever
recalibrated** and the second's counter drifted forever — and nothing prevented
the cycle draining pack A while the loop or arbitrage charged pack B, which is
two power-moving phases on one grid connection pulling against each other.
* **ONE `Maintenance` PER ROSTER ENTRY**, each with its own schedule, phase and
history under `unit/<name>/...`. `store.migrate_maint_keys()` moves an
existing install's flat history into the first pack's namespace under
`migrate_unit_keys()`'s three rules — shared in code, not restated — with the
same read-back postcondition, and the flat keys are kept **live** as the
rollback view so a downgrade finds a current history rather than one dated
migration day.
* **ONE MAINTENANCE SLOT PER SITE.** At most one pack may be in a power-moving
phase (`drain`, `charge` **and** `hold` — `charge` is in the set because a
pack pulled full from the grid beside a pack exporting to empty is 4 kW
circulating with the meter at zero). The holder is **derived** from the packs'
own stored phases, not persisted, so a restart mid-drain re-derives it. When
several packs are due in the same hour the slot goes to the one that has gone
**longest without a completed cycle**; roster order breaks a numeric tie and
nothing else. Nothing preempts a cycle in flight.
* **THE DEFERRED PACK IS NOT STARVED AND IS NOT A FAULT.** A deferral does not
stamp `last_start_attempt` (that is the 90 min post-abort cooldown, inside a
60 min start hour), and does not move the phase, so neither the 12 h `drain`
nor the 36 h `charge` timeout — *"the battery is not following commands"* —
can be reached by waiting. It says WAITING, names the pack it waits for, and
recalibrates at the next start hour; a test drives the winner's whole cycle
and observes it start.
* **THE SCHEDULE IS NOT STAGGERED BY CONSTRUCTION.** The interlock defers and
the stagger is what comes out of it: one contested month separates two packs
by one cycle length and they stay separated. `DECISIONS/MAINT-05-per-pack-maintenance.md`
§3 carries the argument.
* **`validate.py` rule 6 now grades `maintenance_charge_w` against the WEAKEST
cap on the roster**, like rule 5. Its own comment said it would have to move
the day `maint_unit` stopped being `inverters[0]`; that day is this card. It
refuses configurations that used to start — a 3000 W charge beside a 2000 W
pack that is now recalibrated too — which is the `lo > hi` contradiction rule
6 exists to refuse, caught when the config is written. Identical at N=1.
* **AT A ROSTER OF ONE, NOTHING CHANGES**, and it is asserted rather than
assumed: the state file keeps the flat keys and gains none, the migration does
not run, the four cycle events are the shipped strings character for
character, and the status banner is the bare phase with no pack name.
* **THE MIGRATION IS GRADED AGAINST THE ROSTER, NOT AGAINST THE NAME IT WAS
HANDED** (fix round). `migrate_maint_keys()` takes the roster rather than a
pack count and `_verify_moves()` checks the namespace it wrote against the
names the machines actually read. A postcondition that reads back the
namespace it was given cannot detect being given the wrong one: handed
`inverter.UNIT_A` on a roster of `["garage", "shed"]`, the first version of
this card wrote all four keys under `unit/inverter-a/...`, read all four back
equal, reported **verified**, and stamped `maint_schema_version` — so both
packs came up believing they had never been recalibrated and the next start
skipped the migration too. That is now `misdirected`: not `ok`, the marker is
**not** written, and the next start re-runs and recovers (rule 1 makes the
re-run a no-op). `build_roster()` numbers a nameless roster entry
`inverter-1`, so `inverter-a` is not even the fallback for a declared roster.
Every two-pack fixture that could see this now names its first pack
`garage`; with them all called `inverter-a`, `self.inverters[0].name` and
`UNIT_A` were the same string and the swap left all 19 suites green.
* **AND THE REFUSAL NOW SURVIVES THE NEXT START** (second fix round). The fix
above graded only the keys it had just *written*, so it refused exactly once:
measured at Controller level over one persisted store, roster
`["garage", "shed"]`, with the call site still wrong on both starts —
construction 1 `ok=False misdirected=4 moved=4 kept=0 marker=<absent>`,
construction 2 `ok=True misdirected=0 moved=0 kept=4` and the marker
**stamped**. On the second start rule 1 finds the wrong keys already there and
routes all four to `kept`, so `moved` is empty and the roster loop grades
nothing — and start 3 skips the migration forever, *including after the call
site is fixed*. Loud-and-recoverable became silent-and-permanent after one
restart. `_verify_moves()` now grades `set(moved) | set(kept)`; both lists are
built from the same `unit` argument, so grading `kept` grades the same
namespace decision. `test_maintenance.py` part **9c** drives two starts with
the same wrong unit over one store — the shape nothing in the suite had, since
9b measured recovery along the path where the operator has *already* fixed the
call site.
* **AND THE MARKER GATE IS PINNED ON BOTH GUARDS.** `if rep.ok:` is
`not lost and not misdirected`, and the mutation `if rep.ok or rep.kept:`
stamped the marker on a migration that **lost a month of history** with all 19
suites green. Part **9d** is the fixture that separates the two guards: two
keys already namespaced (`kept` non-empty) and two whose write the store
drops (`lost` non-empty), `misdirected` empty throughout.
* ⚠️ **AND THE SAME MUTATION ONE FUNCTION UP WAS A SURVIVOR, FOUND HERE AND
CLOSED.** `migrate_unit_keys()` — SAFETY-02's **latch** migration — gates its
own marker on `rep.ok` too, and every check that reached that gate ran on a
store where nothing was namespaced yet, so `rep.kept` was empty in all of
them. `if rep.ok or rep.kept:` there stamps `schema_version` on a migration
that **dropped the latch**: the guard is off, the file still says
`sign_tripped: true`, and the next start skips the migration that would have
re-armed it. Measured a survivor of all 19 files; now red on
`test_inverter.py` part 10, which drops the `sign_tripped` write beside an
already-namespaced `sign_reason`. No source change — the shipped gate was
right; nothing could see it.
* ⚠️ **FOUND, RECORDED, NOT FIXED (SECOND ONE).** `migrate_unit_keys()` —
SAFETY-02's latch migration — has the identical hole and it costs a **guard**
rather than a history. It runs before `build_roster()` (each `Inverter`
restores its latch in its constructor), so it is handed the constant `UNIT_A`
and there is no roster to grade against. On a declared roster a pre-DEV-02
`sign_tripped: true` lands under `unit/inverter-a/sign_tripped`, which no unit
reads — and `_grade_store_migration()`, whose job is to re-arm exactly this,
is **defeated by the key the defect wrote**: its "is anything namespaced
latched" test is satisfied by the misdirected value itself. Fixing it means
naming the migration's target from the config before any `Inverter` exists,
which is `inverter.py` and SAFETY-02's semantics, with its own battery.
Measured and pinned as a running check (`test_maintenance.py` part 13), whose
assertions state the WRONG behaviour on purpose.
* ⚠️ **FOUND, RECORDED, NOT FIXED.** A maintenance drain **pins** its pack while
the loop's target is a **site** claim, so when the site target is below the
pin the only split asks the sibling to charge against the drain and
`allocator.plan()` refuses it — the site parks at 0 W and the pack's 12 h
timeout would eventually report *"drain stuck"* about a healthy battery.
Pre-existing on `release/1.0` at `2d025ee` with the unit names swapped; fixing
it means changing what the loop's target means while a unit is pinned, which
is loop and allocator territory. Pinned as a running check
(`test_maintenance.py` part 12) so it cannot be forgotten.
**`bms_soc_floor` describes a BATTERY, so at two packs it stops being one number
(SAFETY-32).** The peak guard's energy backstop rests on two figures: the EMS
floor `peak_soc_floor` (the depth a money-saving discharge may never reach) and
`bms_soc_floor`, the percent **that pack's own BMS** cuts out at — register
`0x0560`, read as 10 on the reference GW5000S-BP. Rule 8 refuses an EMS floor at
or below the cut-out, because such a floor can never bind: the BMS wins and the
status page reports a backstop that does not exist. With ONE cut-out for two
packs of different models that rule graded the EMS floor against whichever
battery happened to be written into the flat key, and a site with cut-outs of
10 % and 30 % under `peak_soc_floor: 20` **started** — the guard would then
command a forced discharge that pack B's BMS, not the operator's floor, is the
thing that stops. Rule 8's own failure mode, reached through rule 8.
* **`bms_soc_floor` becomes a per-entry roster key, and it is REQUIRED there.**
Nothing is inherited: an entry that omits it has no cut-out, does not borrow
the flat one, and is refused by name at startup. A per-entry *default* was
considered and declined — a default is one number for every pack, which is the
defect this card removes; `DECISIONS/SAFETY-32-per-pack-bms-floor.md` records
the decision and its migration cost. The flat key is unchanged and is now
documented as the single-inverter shape's own cut-out.
* **Rule 8 grades EVERY unit and NAMES the one it refuses**, through a new
`unit_bms_floors_indexed()` that carries the **roster** index the value came
off. CFG-04 had just fixed a rule 5/6 bug of exactly this shape — a caps-list
index fed to a function that indexes the roster, so the message named the wrong
inverter — and this reader skips nothing, so there is no second list for an
index to desynchronise from. Graded on a roster whose offender is the SECOND
entry *and* on the same two numbers in the other order.
* **The permission is answered PER PACK.** `Controller.pack_floor_soc` — the
emptiest measured pack — is untouched and is still what `decide()` grades;
what changed is the floor. `peakguard.pack_permissions()` answers one
`(name, reason)` per pack against that pack's own floor, and the floor-limited
notification now names the pack that stopped the site rather than "the
battery". At a roster of one the alarm is byte-for-byte what SAFETY-25 shipped.
* **An unstated cut-out withholds rather than defaults.** `None`, not `0.0` —
`discharge_permitted()` already treats an unknown floor as no permission, so
the absence costs a shave and never a pack, including on `sim/inject.py`'s path
which does not run the startup gate.
* ⚠️ **Stated rather than hidden:** under any config rule 8 accepts, the per-pack
*floor* reduces to `peak_soc_floor` for every pack — rule 8 makes it so. The
reduction is written for `unit_caps_indexed()`'s reason ("unreachable" is a
claim about rule ordering, not a property of a function) and is graded on both
sides: 1775 rule-8-valid `(peak_soc_floor, bms_soc_floor)` pairs answer the
option, and the pair rule 8 refuses answers the cut-out. `peak_soc_floor`
itself is still one number for the site, so the "deeper pack needlessly
withheld" half is filed as an open question, not closed.
* **`tools/supervisor_shape_probe.py` re-run and repaired.** MUTATION.md habit 8:
a committed transcript is a check and it decays. The required key broke §C and
left §D printing PASS on a refusal about a *different* key. §D is now an
isolated counterfactual over an accepted, merged baseline, one key varied per
case, asserting the key **name** in the refusal — `all cases passed` on
`amd64-hassio-supervisor:2026.08.0`.
* ⚠️ **SECOND FIX ROUND — the round-2 fix carried the defect it was written to
close, in its prose.** Two more rewrites survived a green 19-file suite on
`8501e05`: `binding_soc_floor()`'s `max(floors)` → `max(floors[-2:])` (+5
bytes) and the call site's `self.packs` → `self.packs[:2]` (+4 bytes). Both are
checks whose TEXT claimed more than their FIXTURE could reach — 12c2's only
counterfactual varied the **last** pack, which every window ending at the
roster's end follows, and all three 12g runs drove a **two**-pack roster, where
`[:2]` *is* the roster. **The general law, now stated in the file: a fixture of
N packs cannot separate two reductions that agree on N packs**, and the regress
does not terminate in a fixture — `[:1]` needed two packs, `[:2]` three, `[:3]`
four. So the reduction is now graded by a **length sweep** (78 simulated
rosters, lengths 1–12, deepest cut-out at every position, closing head and tail
windows of width 1–11 at once) plus a **computed family table** of fourteen
rewrites that goes red naming any member no roster kills; the call site is
graded by **three-pack runs** with the deep cut-out at index 0, 1 and 2, plus
an **exact structural pin** (the roster argument must unparse to `self.packs`)
for the slice widths no bounded roster can reach. Round 3's own battery found
`self.packs[:3]` / `[-3:]` surviving all six behavioural runs — the structural
pin is what closes them — and one row is recorded **NOT CAUGHT**: a reduction
over a window twelve packs wide, which needs a 13-pack roster to observe.
No shipped behaviour changed in this round; only what observes it.
* **Twelve source mutations, eleven red, one argued survivor**, through
`tools/mutation_run.sh` (bytecode purged). The battery also found a real
weakness of its own: `_flat_bms_floor()` had the default in two places and each
covered for the other, so deleting either survived — masking, in three lines of
option reading. One defaulting line now.
* ⚠️ **FIX ROUND — that battery was INCOMPLETE, and the review found what it
missed.** Neither of the two mutations below appears in the twelve rows above:
the ledger graded "the reduction dropped" and "the bare option handed over"
and never asked what happens when the reduction is simply the *wrong* one, or
when the roster handed to it is *sliced*. No shipped behaviour changed here;
two *checks* whose data could not reach the failure they named did. `max(floors)` → `min(floors)` in
`binding_soc_floor()` (zero byte delta) and `self.packs` → `self.packs[:1]` at
the `decide()` call site (+4 bytes) were each green across all 19 files. Both
survived for the same reason: **under any rule-8-valid config every pack's
`pack_floor_pct()` equals `peak_soc_floor`**, so `floors` is a list of
identical numbers and `max`, `min`, first and last are four spellings of one
answer — and the one check using a cut-out above the EMS floor ran on a roster
of ONE, where every reduction agrees. The second also walked through part 12g,
which asserted `"self.packs" in <the unparsed call site>`: a slice still
contains that substring, so the pin passed on the mutation that grades the
whole site against pack A. MUTATION.md habit 4 — a source-text test is a check
on how code is spelled, not on what it does.
* **New part 12c2** evaluates `binding_soc_floor()` on a roster whose per-pack
floors **all differ** — four simulated cut-outs of 30/25/40/35 %, every one
above `peak_soc_floor`, chosen so that `max` (40), `min` (25), first (30),
last (35) and the mean (32.5) are five different numbers and the two extremes
sit at *interior* roster positions. Two packs cannot separate those four;
four is the smallest roster that can. The precondition is its own check
(habit 1) and one pack — the last, neither deepest nor shallowest — is then
raised past the old maximum and the answer follows it (habit 7).
* **Part 12g is now behaviour, not source text.** Real `Controller.cycle()`s on
a two-pack roster, both packs at the same SoC, with the cut-outs as the only
thing varied: move the **non-first** pack's cut-out and the floor reaching
`decide()` moves 20 % → 35 %, with the site's verdict flipping from a sized
discharge to FLOOR-LIMITED. `self.packs[:1]` answers 20 % both times. Which
option key the floor comes from stays pinned on the source where it already
was, because that claim genuinely is about the code's shape.
* ⚠️ **Two MORE survivors, found by this round's own battery and recorded
rather than quietly repaired.** (a) The first cut of part 12g varied only
pack B's cut-out, so `self.packs[-1:]` — grade the site against the **last**
pack — agreed with the full roster on both runs and stayed green across all
19 files (+5 bytes). A two-run fixture pins one slice and not the other.
Part 12g now runs the **same pair of cut-outs in both orders**, so the
deeper one is on the second pack in one run and on the first in another and
the site floor is 35 % in both; no single-position slice passes all three
runs. (b) `binding_soc_floor()`'s empty-roster branch rewritten to
`return None` (−43 bytes) was also green — a defensive branch nothing in the
suite reached. Both directions of it are pinned now, with the note that it
cannot permit anything either way because `pack_floor_soc` is `None` at an
empty roster.
* ⚠️ **THIRD FIX ROUND — the same family was alive at the SIBLING ARGUMENT of
the same call.** Rounds 2 and 3 hardened the FLOOR axis; `decide()` is handed
a second reduction over the same roster beside it, `soc=self.pack_floor_soc`,
and `peakguard.py`'s own docstring names the two as a pair. Three rewrites of
`Controller.pack_floor_soc` were green across all 19 files on `52380c0` and
again after the rebase onto `3934ad7`: `min(float(v) for v in vals)` →
`vals[:2]` (+4), `vals[-2:]` (+5) and `vals[:3]` (+4), while `[:1]`, `[-1:]`,
`[1:]`, `[:-1]`, `max()` and the mean were all red. **The suite's separating
power on the SoC axis stopped at exactly N=2** — the state the floor axis was
in before round 3. It changes a real answer: a three-pack roster at
50 / 60 / 11 % with the emptiest pack THIRD answers 11 % shipped and 50 %
mutated, so the site is graded for discharge PERMISSION against a pack 39
points fuller than the emptiest and spends a pack its own BMS stops. Round 3's
machinery transfers directly — new **part 12i**: six real `cycle()`s with the
emptiest pack at every position of a three-pack roster and both positions of a
two-pack one (the observable read off `PeakDecision.soc`, cut-outs held flat
so the floor axis cannot be what moved the answers); computed slice and
non-slice tables that go red naming any member nothing kills; a **length
sweep** of 78 real rosters, lengths 1–12, closing head and tail windows of
width 1–11 and recording width 12 as honestly unreached; a **none-guard
sweep** over the same 78; and **three exact structural pins** — the `vals`
comprehension must iterate the bare `self.inverters`, and both `any()` and
`min()` must reduce the whole `vals` — which close every slice width at every
roster length. No shipped behaviour changed; only what observes it.
* ⚠️ **SPIKE-04: production is DEGENERATE on the floor axis, so the
differing-floor fixtures are the entire exposure.** Pack B is 4 × Dyness
DL5.0C, DoD 90 → floor 10 % — **FROM THE DATASHEET AND THE SERIAL; inverter B
does not exist and nothing about it is measured.** Pack A is DoD 90 → 10 % as
well, and that one *is* measured. Both packs therefore floor at the same value
in the field, `max(10, 10)` is 10 whatever it reduces, and a differing floor
exists **only in the fixtures**. That is the argument for keeping them, not for
simplifying them: anyone who collapses `A_PACK_FLOOR != B_PACK_FLOOR_SIM` to
one number deletes the only data this repository has that can see the
reduction at all, and part 12c2's precondition check goes red if they do. The
**SoC** axis has no such degeneracy — two batteries at the same state of
charge is a coincidence, not a configuration — which is what makes
`pack_floor_soc` the half of the pair that will be live from the day inverter
B is wired up.
* ⚠️ **The FAMILY enumerated rather than the member closed, and it found four
more survivors in code this card never touched.** Every reduction over
`self.inverters` / `self.packs` in `Controller` was found from the AST and
mutated to a slice against the full suite. Eighteen were already graded
(`site_batt_w`, `site_rating_w`, `site_max_w`, `site_dev_bound`,
`site_circulating_w`, `inputs_ok`, `units`, `Controller.packs`, `maint_unit`,
the maintenance-due minimum, the store-migration roster, `validate_unit_ranges`
and the round-2/3 sites). **Four were not, and three of them are SAFETY-30's,
all `any(i.sign_wd.tripped for i in self.inverters)`** — `cycle()`'s
stale-input hold, `publish()`'s status vocabulary and `status_payload()`'s
banner — each +4 bytes and green across all 19 files, for the reason every
blocker on this card was invisible: **the only fixture that reached them was a
roster of ONE, where `self.inverters[:1]` IS `self.inverters`.** The first has
teeth: a latched unit must take the roster past that hold or its `failsafe`
SET stops being re-filed the moment a poll is missed, which is main.py's own
sentence for it. New **test_watchdog.py part 8** grades all three with the
latch at EACH position plus a no-latch counterfactual, and new **part 12j**
pins all 26 roster comprehensions in `Controller` to iterating the roster
whole — so a reduction added over a slice anywhere in the class is red on the
line it is written, with no fixture required. Two rows are reported open
rather than closed: `_grade_store_migration()`'s second disjunct (now red on
12j, and argued to be an equivalent mutant because a unit tripped at startup
implies its namespaced key is set) and `cycle()`'s undeliverable-unit **log
line**, where `sorted(...)[:1]` (+4 bytes) is still green — it truncates names
in one event message; the refusal itself is a different expression and is
graded, so the site still stops.
* ⚠️ **FOURTH FIX ROUND — the same family one MODULE over, and the pin widened
until it discovers its own scope.** Round 4 enumerated the family and closed
it inside the `Controller` class; the review found four more survivors
immediately, in **validate.py**, on a 19/19 green suite: `min(caps)` →
`min(caps[:1])` (+4) and `→ min(caps[-1:])` (+5) at `:779`, the caps
comprehension over `caps_ix[:1]` (+4) at `:778`, and
`min(caps_ix[-1:], key=…)` (+5) at `:893`. **None is an equivalent mutant.**
With `max_w: 5000` on inverter-a beside `2000` on inverter-b and
`sign_disagree_w: 3000`, the shipped validator refuses — *"the SAFETY-02
sign-disagreement watchdog can never fire"* — and all four **accept**: the
site starts with a watchdog reporting `armed` that cannot trip on pack B.
Rule 5's own failure mode reached through rule 5; rule 6 loses its refusal the
same way. **No shipped behaviour changed by the pin; what changed is that a
hand-written scope stopped being trusted.**
* **`test_peakguard.py` part 12j now parses every `.py` under `app/`** — no
module is named in the check — and finds the roster by transitive closure
from **one seed**, the `inverters` option key: through returns, through
lists **accumulated in a loop over a roster** (which is what `caps`,
`roster` and `problems` are, and what round 4's rule could not express),
through attributes and properties, and **through call arguments**, which is
how it walks into `peakguard`, `arbiter`, `allocator`, `circulation`,
`maintenance` and `store` without being told they exist. A slice of a roster
stays a roster so a mutation cannot cut the taint; an index is one unit and
does not. **183 reductions across 9 modules** out of 23 files parsed — `main.py` 96,
`allocator.py` 24, `validate.py` 19, `arbiter.py` 14, `circulation.py` 10,
`maintenance.py` 10, `peakguard.py` 4, `inverter.py` 3, `store.py` 3.
* **The hand-written module list would have been wrong in BOTH directions.**
It named `watchdog.py`, which reduces over no roster at all — SAFETY-30's
sign watchdogs are strictly per-unit — and omitted `maintenance.py` and
`store.py`, which both do. A vacuous claim about one module and no claim
about two others.
* **The pin rediscovers all four blockers without being told where to look,**
and finds a fifth beside them (`validate.py:783`, rule 5's message) that no
review round named. Its counterfactual runs at two depths: every enumerated
site's own expression mutated with each of the four cuts this card has been
defeated by (732 spellings, all reported), and `[:1]` written into
`app/validate.py` at each blocker position with the **whole** analysis
re-run over the mutated source — a sliced site required at that exact line,
where the clean package reports none.
* **And the behavioural half, because a shape pin grades an identity and never
a meaning.** `test_validate.py` grows a **roster SET** for the three rules
that reduce over `unit_caps_indexed()` — widths 2, 3, 4, 5 with the one
small cap at every position, 42 runs of the real validator — plus a
**computed family table** of twelve candidate reductions each compared with
what the shipped validator actually said on the same roster. Only `min`
agrees everywhere; a member no roster kills is printed as a named survivor.
* ⚠️ **A THIRD RULE WAS READING THE FLAT `max_w`, AND IT IS SAFETY-30's** —
found by reading, **not** by the pin, which is the shape of what the pin
cannot see. `unit_sign_disagree_w` was graded against
`_number(opts, "max_w", 2000.0)` three lines under a branch that had already
stopped doing that. **Both directions were measured:** two 2000 W units
beside a leftover `max_w: 5000` and `unit_sign_disagree_w: 3000` produced
**zero problems** — the site started with a per-unit watchdog that could not
trip on either unit — and two 5000 W units with no flat key were **refused**
against a 2000 W default the operator never wrote. It takes the weakest
unit's own cap now and names that unit; at a roster of one it is the same
comparison, boundary and sentence it always was.
* ⚠️ **What the pin cannot see, with sizes**, in
`DECISIONS/SAFETY-32-per-pack-bms-floor.md` §4d: semantics (`min` vs `max`
is a zero-byte edit); direct index sites that are not reductions; a
subscript by a *variable* (`weights[u]` is why); a slice through an
intermediate call; anything outside `app/`, including `sim/inject.py`; and
the taint's own seam at `*args` and unresolvable receivers, where everything
downstream goes **unenumerated rather than reported unreachable**.
`cycle()`'s undeliverable-unit log line is still green at +4 bytes and still
filed open, unchanged from round 4.
* **`tools/supervisor_shape_probe.py` re-run again (2026-09-05, 2026.08.0).**
The rebase onto `67e649a` merged SPIKE-04a's `max_w: 4600` into the same
§C/§D blocks this card had rewritten, and a transcript stitched by hand out
of two runs is not a measurement. `all cases passed`, exit 0, with B's
rating reading 4600 — its **datasheet** figure, still not a measurement of
any unit.
* ⚠️ **THE SWEEP, AND THE NUMBER THAT MUST NOT BE QUOTED ALONE.** All 183
sites mutated to `[:1]`, one at a time, against the full 19-file suite in
`goodwe-addon-ci` (`:ro`, `-B`, fresh rsync per mutant, 0 `.pyc` before and
after): **183/183 RED** — which is tautological on its own, because the pin
makes every slice red. The 51 whose first red was `test_peakguard.py` were
re-run with the pin **neutralised**: **145 of 183 have a behavioural fixture
that separates them from a slice of themselves; 38 have only the structural
claim.** All 38 are listed by site, with what a `[:1]` there would cost, in
§4d and in `test_peakguard.py` part 12j — 15 of them are rows and counts on
the operator's page, 3 are `len(targets)` arithmetic beside a write path
that IS graded, 6 are allocator internals ALLOC-01's fixtures reach but not
with enough units to separate. **None of the 38 is closed behaviourally by
this card, and none is counted as covered.**
⚠️ **No measurement of inverter B appears anywhere in this change.** It does not
exist yet. Every second-pack figure — in fixtures, in the probe, in
config.yaml's commented example — is **simulated and labelled**; only inverter
A's 10 % is read off hardware.
**At two inverters the sign watchdog stops comparing one unit against the whole
site meter, and becomes two checks instead of one (SAFETY-30).**
`disagrees(commanded_w, grid_w, ...)` compared the command **this controller put
on ONE actuator** against **what the whole site** is exchanging with the network.
At a roster of one those are two views of the same thing - §6.2's identity - and
that is what makes the check sound and what earned it the best record in the
safety table. At two they are not, and it fails **in both directions**: inverter
A commanded −1500 W while the meter reads +1500 W is evidence of nothing when
inverter B is discharging 3000 W exactly as told, and - worse - a unit genuinely
driving the wrong way is **MASKED** by a sibling that covers for it, because the
site figure nets. No threshold recovers that; the summation destroys the
evidence.
* **PER UNIT: each inverter's own share against its OWN measured power**
(`Inverter.batt`, holding register 0x0518, per-instance since DEV-02).
Conclusion: *the actuator I am driving is not doing what I told it* - evidence
about one device, so the remedy stays the per-unit `failsafe` SET that
`arbiter.CLAIM_SCOPE` has classified `SCOPE_UNIT` since it was written. That
entry read *"the evidence is site-wide and the remedy is not"*; after this card
the first half is simply true. Verified by making one unit reverse while its
sibling covers it at the meter: the shipped comparison is false on **0 of 14**
cycles while the new one convicts that unit on every one, and only that unit is
parked.
* **SITE: the SUM of the standing commands against the meter**, as a new
`sign_site` SET at `P_SAFETY` on the site actuator, latched under flat
`site_sign_tripped` / `site_sign_reason`. This is the fault the 2026-08-20
capture contains and **no per-unit check can see it**, because every inverter
is faithfully executing its share - what is wrong is the number they were
given. It stops every inverter and the banner names the site rather than an
inverter, so nobody is sent to swap the wrong box.
* **⚠️ Different questions from SAFETY-31, and the PR and the decision record
both say which.** `circulation.py` compares the units **against each other**
and catches two inverters pushing *through* each other, which nets to zero at
the meter and which no single command is evidence about. This compares each
unit against **its own command**. They overlap in exactly one scenario - a unit
reversing while its sibling pulls the other way - and `test_watchdog.py`
asserts on that fixture that both fire and what each concludes. It is also not
the saturation freeze: that is a magnitude test (`|command − measured| >
500 W`) that shapes the loop and fires on a merely saturated unit; this is a
direction test that latches and parks one.
* **⚠️ All four thresholds RE-DERIVED at two inverters - one carried with a
justification, one refused.** 1890 closed-loop runs in which nothing is faulty,
over the whole range `config.yaml` accepts for `gain` and `slew_w`, across load
reversals with write staggers and flapping loads, **run at both rosters so the
N=1 arm is the control.** `unit_sign_disagree_w: 250` is `saturation_w / 2`, so
the smallest divergence this can see is exactly the gap at which the control
law itself already says the inverter is not following; `unit_sign_disagree_s:
85` is 8.5× the worst legitimate opposition those runs produce (10.0 s), 2.8×
the firmware's own 30 s link veto and under half the site hold.
`site_sign_disagree_w: 300` is **carried** - its argument is the meter's noise
floor and the deadband, and the roster touches neither. **`site_sign_disagree_s`
is NOT: 180 s would have shipped a false trip.** The worst legitimate crossing
at 300 W is 110 s with one inverter and **215 s with two**, because the command
must travel a rail that is the roster sum at a `slew_w` that is not - reachable
at `gain: 0.05`, `slew_w: 50` and a 2.2 kW load reversal, all schema-legal.
325 s is 1.51× that, inside the 900 s billing quarter and inside every episode
of the fault day. See `DECISIONS/SAFETY-30-per-unit-sign.md`.
* **⚠️ At ONE inverter this changes nothing, and "nothing" is asserted rather
than assumed.** The two questions are the same sentence at a roster of one, so
only the detector that shipped is armed: same comparison against the meter,
same 300 W / 180 s, same reason string byte for byte, same namespaced latch and
flat rollback mirror, same `failsafe` claim, same banner, same single status
row - and the site detector's window is never so much as opened.
`unit_sign_disagree_*` and `site_sign_disagree_*` do nothing on a
one-inverter install.
* **The threshold WIRING is pinned, not just the threshold values.** Review
found that `arm(self.sign_cfg if one else self.unit_sign_cfg, ...)` could be
collapsed to `arm(self.sign_cfg, ...)` — arming every unit with the
meter-facing pair instead of the re-derived per-unit one — with all 19 test
files still green, because nothing at a roster of two read `sign_wd.cfg` and
the trips in the fixture happen under either pair. `test_watchdog.py` part 3
now asserts the pair and the instrument on **every** detector against
literals, and the fixture's three threshold pairs were made pairwise distinct
in both coordinates so that a hold delivered from the wrong pair cannot
compare equal to the right one. M14–M16 in
`DECISIONS/SAFETY-30-per-unit-sign.md` §5.
* **Known and recorded rather than fixed:** the site comparison is defeated by a
square-wave load whose half period is about one control cycle, which holds it
opposed for ~1000 s at *both* rosters. The N=1 control arm is what says this is
a property of comparing a lagged command against a meter and has nothing to do
with the second inverter, so it is not acted on here - it wants an alternation
test, not a number, and a card of its own.
**An operator can declare a second inverter, and the shape was measured against
the Supervisor rather than assumed (CFG-04).** DEV-02 made rating, SoC,
watchdogs, heartbeat and store keys per-instance, so the code no longer assumed
one inverter — but the options schema still described exactly one, and
`build_roster()` returned a list of length one and said so in its own docstring.
The roster could only ever be a roster of one. **Version bumped to 0.6.0,
because the Supervisor keys the built image by `version:` and a schema change
without a bump is a schema nobody reads.**
* **`inverters:` — a list of objects, defaulting to `[]`.** Empty is not
"unconfigured", it is **the single-inverter configuration**: the flat
`setpoint_entity` / `soc_entity` / `batt_entity` / `batt_invert` / `max_w`
keys describe the one unit exactly as they always did. An install that
upgrades reads identically — same entities, same rating, same behaviour, no
operator action, and the whole existing check suite runs against it unchanged.
* **⚠️ The shape was ESTABLISHED, not assumed, and the empty default is the
load-bearing part.** There was no list-of-objects anywhere in `config.yaml`
and `static_profile` carries its structure as a JSON string in a `str?`
precisely because a nested schema was doubted. So Supervisor **2026.08.0**'s
own `AppOptions` validator — the version this site runs — was run against this
repository's `config.yaml` out of the release image
(`tools/supervisor_shape_probe.py`, committed; the transcript and the
reasoning are in `DECISIONS/CFG-04-inverter-roster.md`). It accepts the list,
enforces per-entry types, refuses a missing `name` / `setpoint_entity` /
`max_w` **by name**, and renders the option in the UI as a repeatable section.
And the shipped `options:` block validates as it stands while the **same
block with only `inverters` removed** is answered with **`Missing option
'inverters' in root`** — one key varied, so the refusal is about that key —
which is every options blob written before this version, since the key did not
exist when they were written. `App.options` is
the shipped `options:` block deep-merged with the operator's stored one, so
`inverters: []` in `config.yaml` is the difference between an upgrade nobody
notices and an add-on that cannot start with a schema pinned to the version
that would fix it. That is `docs/deploy-rollback.md` §4's trap in the forward
direction, found before it was sprung rather than after.
* **Nothing is inherited by an entry that omits a key, and that is DEV-02
restated as a config rule.** `name`, `setpoint_entity` and `max_w` are
required of every entry; a missing `soc_entity` means *this unit has no SoC
sensor*, never *use the other one's*. A three-line fallback to the flat keys
would have rebuilt the sibling-grading defect DEV-02 spent a card removing, in
YAML. Defaults still live in exactly one place (CFG-03): there is no
per-entry default anywhere, because there is no optional per-entry number.
* **SAFETY-28's `actuator_writers()` refuses two inverters naming one
`setpoint_entity` — the first configuration in this add-on's life in which
that was expressible.** The census was already structural and case-folding, so
it needed no change; what it needed was a config that could express the
hazard, and now there is one. Its sibling refusal is new: a flat
`setpoint_entity` left set beside a declared roster names an actuator nothing
will write, and is refused rather than ignored.
* **⚠️ Two PERMISSIVE READERS in shipped code, found and fixed.** Both failed in
the direction that hides a defect. (1) `validate.py` rules 5 and 6 compared
`sign_disagree_w` and `maintenance_charge_w` against the **flat** `max_w`; at
a roster of two 2000 W units with `max_w: 5000` left over from a
single-inverter install, `sign_disagree_w: 3000` passed rule 5 while
SAFETY-02's watchdog could fire on **neither** unit — rule 5's own failure
mode, reached through rule 5. They now read the roster's caps
(`unit_caps()`), which at one inverter is `[max_w]` exactly. (2)
`run_control()` re-ran the device-rating check behind `if
self.o.get("setpoint_entity")` — the flat key, which a roster config leaves
blank — so on a two-inverter site **no** inverter's `max_w` was ever graded
against the device it is written to. `validate_unit_ranges()` grades each unit
against its own ESPHome and runs unconditionally.
* **⚠️ Three config.yaml READERS IN THE CHECKS took the first match on a
stripped line, and one of them was already known.** `test_peakguard.py`'s
`read_option()` and `_schema_bound()` and `test_inverter.py`'s
`read_schema_max()` threw indentation away, so the nested per-inverter
`max_w:` began outranking the flat one — **silently, and correctly**, because
the two bounds are the same `int(100,5000)` today. A reader that is right by
coincidence is the failure mode this project is named after. All three are
anchored at exactly two spaces now, the halves of the file disambiguate
`peak_cap_w` instead of first-match, and an ambiguous key raises rather than
picking one. `test_tariff.py`'s copy of the idiom went with them.
* **The audit is a check, not a promise.** `test_inverter.py` part 11 finds
every `config.yaml`-reading function in the suite — transitively, so a reader
that never names the file because it delegates is still found — **executes**
each one against a synthetic two-inverter `config.yaml` whose per-inverter
numbers differ from its flat ones, and fails if any returns the per-inverter
value. The table is not maintained by hand: the signature decides, so the
eleventh reader is named on its first run. `config.yaml` declares `inverters:`
**before** `max_w:` on purpose, and part 11 asserts that ordering, so the trap
stays baited rather than sorted out by an ordering nobody would maintain.
* **Ten mutations run and observed red** (`tools/mutation_run.sh`), listed in
`test_inverter.py` part 12 with the check that bites each. **Two survived the
first run and the checks were changed, not the table:** the inheritance check
had blank flat keys, so "inherited" and "not inherited" were the same empty
string; and the `run_control()` check asserted a **source line** was present,
which re-indenting it does not remove. The second is now driven through the
shipped `run_control()` under a deadline, because that mutation's real symptom
is a hang rather than a red.
**Circulating power - two inverters pushing against each other - becomes a
measured quantity, a bounded one, and an alarm that survives a restart
(SAFETY-31).** Inverter A charging at 3 kW while inverter B discharges at 3 kW
nets ~0 W at P1: the site reads idle while the packs are cycled through two
round-trip conversion losses continuously. **Every guard in this add-on is a
consumer of that net figure**, so none of them can see it - SAFETY-02's sign
watchdog gates on `abs(grid_w) > 300` and the gate never opens, and both the
peak guard and the capacity tariff bill grid exchange.
* **A site sensor, `Σ|Bᵢ| − |ΣBᵢ|`.** Zero when the units pull the same way,
`2 × min(|B_a|,|B_b|)` when they oppose. Published as
`sensor.goodwe_circulating_power` beside the grid figure, because *"grid 0 W,
circulating 6000 W"* is the whole phenomenon in two dashboard rows and no
arithmetic on the grid figure alone can produce the second one.
* **⚠️ Derived from MEASURED per-inverter power, never from the allocation
record, and that is the whole card.** ALLOC-01's sign-coherence gate
(`REFUSE_SIGN`, its AC 7) already refuses any allocation whose shares carry
two signs, so a record-derived sensor reads zero **by construction** and could
only ever confirm that the allocator agrees with itself. What this detects is
circulation **nobody commanded**: a unit ignoring or lagging its share, a
stale share still being executed, a maintenance or SAFETY-25 pin holding one
unit while the loop drives the other, or HW-01's power stage running its last
instruction for **6 h 25 m** with the comms dead and the allocation record
impeccable throughout. Verified by making one unit ignore its share on the
TEST-19 rig: the record stays `ok` with both shares at −1250 W - a
record-derived sensor reads **0 W** - while the shipped sensor reads
**2000 W**. `Inverter.batt` became per-instance in DEV-02; before that this
sensor could not have been written.
* **The trip stops the site, and the decision record says why that is an action
rather than theatre.** Sustained opposition files `Claim.set("circulation",
P_SAFETY, 0.0)` on the **site** actuator - every inverter to 0 W, latched.
HW-01 established that a wedged inverter cannot be commanded at all, so the
remedy is not aimed at it: a circulating loop needs **two** participants and
**one of them is this controller**, faithfully driving the listening sibling
into the one that stopped listening. Stopping halves the loop, and - the more
important half - **makes the residue visible at the meter**, where every
existing guard can finally see it. What it cannot do is stop the wedged unit;
the notification says so, and names the isolator as the last actuator.
* **The threshold and the window were measured, not chosen (AC 3).** 924
closed-loop runs on the TEST-19 two-master rig in which *nothing* is faulty,
swept over the whole range the schema accepts for `gain` and `slew_w`. Worst
**continuous** legitimate opposition by threshold: **505.0 s at 100 W, 40.0 s
at 250 W, 10.0 s at 300 W, 5.0 s at 400 W and above**. The knee is 400 W and
it is the schema floor. `circulation_w: 700` is 1.75× it, the headroom bought
for inverter B's ramp and lag being **placeholders until SPIKE-04 measures
them**. `circulation_hold_s: 75` clears three bounds - 15× the worst
legitimate episode (5.0 s), 2.5× the firmware's own `LINK_STALE_S` veto, and
12× inside the 900 s capacity-tariff quarter. **A momentary opposition while
one inverter slews through zero is legitimate** - the serialised write path
lands B's number up to a control cycle after A's - and the guard does not fire
on it, in any of the 924 runs.
* **The alarm survives a Home Assistant restart (SAFETY-34).**
`persistent_notification` is in memory, which is exactly how the 2026-09-02
outage went unseen for 6 h 25 m with the detector correct throughout. The
latch is persisted to `/data` as flat, site-level keys - flat because the
quantity is defined over the roster and is identically zero for any one unit,
so there is no inverter to attribute it to - and the notification is
**re-raised on the first cycle after every start**, through the same code path
as a fresh trip.
* **At one inverter the sensor is identically zero and nothing changes (AC 5).**
`|B| − |B| == 0` for every reading, including one nobody took; no claim is
ever filed, the arbitration is byte-identical, and the status page says *n/a*
rather than claiming to watch something that cannot happen.
* **Verified by breaking it.** 18 mutations against the sensor, the window, the
latch, the claim, the store, the alarm, the routing table and both config
copies - **all red**, each on a named check; one equivalent mutant argued
rather than claimed; and one genuine **survivor found and closed** (`publish()`
turning an unknown into a published `0 W`). `arbiter.CLAIM_SCOPE` gains its
ninth source and `test_peakguard.py`'s 10f/10g tripwires were updated
deliberately, as their own comments require. Full ledger in
`DECISIONS/SAFETY-31-circulating-power.md`.
**Every per-device value stops being a Controller scalar: rating, SoC, battery
power, watchdogs, heartbeat, write bookkeeping and store keys are now
per-instance (DEV-02).** `app/inverter.py` introduces an `Inverter` object that
owns its entities, its rating, its device range, its `SignWatchdog`, its
`last_write` and its `last_beat`, under **store keys namespaced by unit name**.
The Controller holds a list of them and keeps only what is genuinely site-level:
the P1 reading, the site integrator, and the tariff quarter.
* **What the scalars were silently asserting.** One `dev_min`/`dev_max` pair was
read from one `setpoint_entity`, so a second inverter's rating was **never
read at all** and its clamp, its freeze rail and the peak guard's
`achievable_w` were the first one's numbers. One `soc` fed the maintenance
FSM, SAFETY-24's pack floor and arbitrage's bounds. One `SignWatchdog` - whose
own docstring says *"one instance per actuator"* - latched under **flat** store
keys, so a trip caused by B latched A across restarts and one operator press
cleared both. One `last_beat` and one serialised `hass.call()` meant a hung
write to A ate B's 30 s layer-1 budget.
* **`actual_w` became SITE level while the readings became per-instance, and
those are opposite directions on purpose.** `compute()`'s anti-windup test is
`abs(prev_w - actual_w) > saturation_w` with `prev_w` the **site** target, so
feeding it one inverter's power compares a site number against a unit number,
trips the saturation freeze permanently and leaves a standing grid error.
Measured on `admin/goodwe`'s two-master rig, 2 kW load: with one unit's power
the aggregate trace at the meter is split-dependent by **510 W at `gain: 0.2`,
250 W at 0.4 and 50 W at 0.6**; with the site sum **every split is
bit-identical at every gain the schema accepts**. That was ALLOC-01's
disclosed finding, graded in `test_alloc.py` part 8 and now closed there.
* **The store migration is graded, not merely performed.** `sign_tripped` /
`sign_reason` move to `unit/<name>/...` once, verified by **reading back**
what was written, and the version marker is only set when nothing that carried
state was lost. The flat keys are left in the file so a rollback still finds
its latch. And `Controller.__init__` compares the pre-migration flat latch
against what unit A actually came up with: if the latch did not survive it is
**re-armed from the legacy value and shouted about**, because a latch that
silently fails to migrate is a disarmed safety guard on an install whose state
file says it is protected.
* **Heartbeats are independent, and the budget is derived.** Each inverter owns
its own deadline, the refreshes are dispatched **concurrently**, and each write
is bounded by `WRITE_BUDGET_S` (4 s). The inequality that fixes that number is
graded rather than asserted: `4 + heartbeat_s`'s schema maximum of `25 < 30`,
layer 1's `FIRMWARE_INGEST_VETO_S`. Verified by injecting a transport that
accepts and never answers: B's write reaches the wire while A is still
hanging, and the serialised shape it replaces is run beside it.
* **`live_units()` answers honestly.** A unit whose every write has been rejected
for a whole layer-1 window is not commandable; the allocator drops it, the
survivors carry its share, the action log names it, and the dropped unit is
commanded **0 W** rather than left standing on its last share. A roster entry
with **no** `setpoint_entity` is deliberately *not* handled there - that is a
configuration that cannot be delivered, and it reaches main.py's refusal
branch, which commands 0 W and names the inverter.
* **At N=1 nothing moves.** The removed scalars survive as read/write properties
of the sole inverter, so every existing replay in this repository runs
unmodified - and they **refuse at N>=2** rather than answering for the first
inverter, which is the tripwire on a consumer that was never made
per-instance. `test_inverter.py` is the new file (77 checks); `test_alloc.py`
part 8, `test_peakguard.py` 10g/10h, `test_watchdog.py` and `test_clamp.py`
were re-aimed rather than relaxed.
* **Inverter B still does not exist.** `build_roster()` returns exactly one
inverter, from the flat options, and is the one function CFG-04 changes. Every
two-unit figure above is architecture, not a measurement of a second device;
the second rating in the checks is marked as a hypothesis.
**The write path is gated on the allocation record, not on how many config keys
exist (SAFETY-28).** specs §1.5 makes *"any configuration in which two writers
can reach one actuator"* a non-goal. Until now that non-goal was enforced by
`len(validate.ACTUATOR_WRITE_KEYS) == 1` - there is exactly one option key, so a
second writer is not expressible in the schema. True, and a statement about **the
shape of the options schema rather than about the writes**: add a per-inverter
config (CFG-04) and there are two real writers with that length still 1, so the
check stays green while the property it protects is gone. `sim/inject.py`'s
`two_writers` scenario asserted on the same tuple and went green with it.
* **The enforcement moved onto the writes.** `write_setpoint()` now refuses any
value that is not in **this tick's** allocation record from ALLOC-01:
`Controller.write_refusal()` asks `Allocation.authorises()` whether the single
allocator placed exactly this number, for this unit, on this tick. A second
writer with arithmetic of its own cannot satisfy that - its number appears in
no record - so it has to file a `Claim` and go through `resolve()`, which is
the one allocator. "Exactly one allocator per shared resource" stops being a
convention and becomes something the write path checks.
* **A refusal is a refusal, not a log line.** The unauthorised value is replaced
with **0 W and written**. Returning instead would leave the inverter latched
on its last command with the ESP32 heartbeat still being fed - holding an
unauthorised setpoint quietly, which is the outcome the gate exists to prevent.
* **A stale record cannot be replayed.** Every record now carries the `tick` it
was made for, handed *in* by the caller so `allocator.plan()` stays the pure
function `test_alloc.py` part 10 grades. The counter advances **once per
resolution, not once per loop iteration**: a new allocation makes the previous
record stale immediately, while the "inputs missing, not yet stale" hold -
which returns before the allocator runs, so one dropped meter reading does not
zero the inverter - leaves the standing authorisation intact for the heartbeat.
An **unstamped** record authorises nothing; "I cannot say when I was made"
fails closed.
* **⚠️ 0 W IS AUTHORISED UNCONDITIONALLY, SO THE FAILSAFE CANNOT DEADLOCK BEHIND
THE GATE.** `write_setpoint()` is also how layer 2 commands zero, and every
path that does so - `cycle()`'s two refusal branches, `shutdown()`, the
operator's stop button - runs while the allocator has *refused*. A gate that
asked the allocator's permission to command zero would block the safety write
behind the very component whose failure the safety write answers. The
exemption is on the **value**, not on a `failsafe=True` flag a caller asserts,
and the argument is that the hazard §1.5 names is N-times loop gain from
*broadcast*: at `S = 0` the broadcast and the correct allocation coincide -
`a_i = 1` for every unit gives every unit 0 W, which is exactly its share - so
there is no over-command to make at zero. Driven end to end through the real
refusal branch in `test_clamp.py` part 7c.
* **`unmet_w` is still not `ok`.** The gate reads `ok` and the unit's share and
never `unmet_w`, because an allocation that could not place every watt is
still safe to write; fusing them would let one saturated inverter park the
whole site. Graded on a record with 3800 W unmet.
* **`ACTUATOR_WRITE_KEYS` is replaced by `actuator_writers()`**, which counts
**writers per actuator** rather than option keys, and finds them by walking
the options tree rather than by looking for a container name CFG-04 has not
chosen yet. Two inverters with two entities are accepted - that is what the
per-inverter roster is *for*; two declarations aimed at one entity are refused,
naming the actuator and every writer pointed at it. The tuple survives only as
the enumeration a census needs, and nothing asserts on its length any more.
* **What neither check observes, said out loud.** The census sees *configured*
writers, so a second write path added in **code** is invisible to it - exactly
as it was invisible to the tuple. That half is closed at runtime by the record
gate, which does not care what the options look like or who called the method.
* Verified by breaking it: seven mutations on a purged tree via
`tools/mutation_run.sh` - removing the gate, making the zero exit an amnesty,
dropping the tick comparison, deleting the census refusal, fusing `unmet_w`
into `ok`, freezing the tick on the live path, and moving the gate below the
clamp - each turn `test_clamp.py` or `test_validate.py` red.
**The site grid target is now ALLOCATED across N inverters, sum-invariant, and
never broadcast (ALLOC-01).** `ARB-03` left `allocate()` as a documented seam
that passed through at N<=1 and DECLINED at N>=2; this fills it. The new
`app/allocator.py` turns one site target `S` into per-inverter shares with one
invariant - **`sum(shares) + unmet_w == S`, in integer arithmetic** - and each
inverter is then told a function of **its own share**, never of the shared
measurement.
* **Why a broadcast is a fault and not merely an inefficiency.** The control
primitive is meter emulation: the master reports a *fabricated grid reading*
and the inverter regulates itself to it, so one number means "the battery
moves X W" here and "the grid is at X W" there - an identity that holds only
at N=1. Hand both inverters the same target and each supplies it in full, so
the loop gain at the meter becomes N times the per-unit gain. Measured on
`admin/goodwe`'s two-master rig (TEST-19): **-400 W export overshoot at
`gain: 0.6`, and at `gain: 1.0` - which `config.yaml` accepts as its
documented maximum - a permanent 4000 W peak-to-peak limit cycle with not one
guard firing.** The sign watchdog is evaluated on every cycle and never trips,
because the disagreement flips on alternate ticks and never holds its 180 s
window.
* **The stability property is structural, not tuned.** With `sum(a_i) = 1` the
gain at the meter is `sum(a_i * g_i)`, a **convex combination** of the
per-unit gains, so it lies in `[min g_i, max g_i]` **for any split**. That is
what makes the weights a comfort choice (SoC, thermals, wear) rather than a
tuning parameter, and it means a bad split cannot destabilise the site.
Graded directly in `test_alloc.py` part 9, and measured end-to-end: a 90/10,
a 50/50 and a 100/0 split produce a **bit-identical aggregate trace at the
meter**, and a gain sweep to 1.0 at every split shows a flat tail at all 84
combinations.
* **Rounding is a safety property here.** The register is 1 W, and a per-unit
`round()` biases the sum - measured at **-125 W over 50 000 ticks at three
inverters**. At 1-2 Hz that is a permanent standing error the site integrator
chases and never reaches. So the target is rounded **once**, at the top, and
the fractional parts are settled by **largest remainder** with a deterministic
tie-break; every sum below that line is integer arithmetic and cannot drift.
Verified over 250 000 randomised ticks: **0 sum failures, 0 envelope escapes**,
and the one rounding that is left - the single site-level `quantisation_w`,
never distributed into a per-unit bias - totals **-39.8 W over 137 964
allocations, i.e. -0.0003 W per tick.**
* **Each share is clipped to that unit's interval, and THE TWO ENDS OF THE
INTERVAL ARE APPLIED INDEPENDENTLY.** `UnitBounds()` defaults to
`(-inf, +inf)`, so a one-sided envelope is the ordinary case at N>=2 rather
than an edge. The first cut of this work folded both ends into one
`min(max(v, lo), hi)` and substituted `v` itself for a missing bound, which
reads as "an absent bound cannot bind" but is not what it does: with
`hi == inf` the expression collapses to `min(max(v, lo), v) == v`, so **a
missing ceiling silently discarded the floor.** `_clamp_int(0, 2142, inf)`
returned 0. The worked failure it caused: a unit with a 2000 W floor and no
ceiling, beside a symmetric unit, against a +1000 W site target, was allocated
**+500 W - a quarter of its own floor** - and the sign-coherence refusal that
the same case with a finite ceiling correctly raises was **suppressed** with
it. Fixed by clamping each end on its own, and `UnitPlan.explain()` can no
longer print a share as being inside an interval that excludes it: that line
now reads `OUTSIDE ... - ENVELOPE VIOLATED, DO NOT WRITE`.
* **The envelope is read per tick, never cached.** `plan()` is a pure function
of that tick's intervals and holds no state, because a unit's range moves for
reasons unrelated to the allocator - a stale link, a pack at its floor, a
device rating that failed to read.
* **A dead link is announced, not absorbed.** A unit whose master is stale is
dropped from the envelope set; the survivors carry its share, and the
allocation record names the unit and the reason so `main.py` logs it. A site
running at half its inverters and reporting nothing reads as healthy on every
dashboard.
* **Opposite directions are refused, not averaged.** One pack discharging while
another charges nets to exactly the right number at the meter, so no existing
guard can see it. A sign-coherence gate makes it inexpressible.
* **`scope_violations()` is now consumed, and it is consumed as a refusal.**
ARB-03 left it logging without changing the resolution. A mis-routed claim
means the number about to be divided may itself be wrong, and dividing a
number that may be wrong is worse than not dividing it - the same answer
clause 3 already gives a contradiction. It is *not* promoted into an envelope:
a unit-scoped claim that landed on the site names no unit, so promoting it
would mean guessing one.
* **At N<=1 it is a pass-through, byte-identical.** The share is the site
target, as a float, unrounded and unclamped. Every one of the existing suites
replays unedited and green.
* **`main.py` still refuses to act at N>=2, for a new and narrower reason.**
There is one `setpoint_entity`, so this controller can command one inverter; a
valid two-way split names an inverter it has no writer for, and commanding a
partial site is a worse instruction than commanding nothing. The old
"no allocator" refusal and its test (`test_peakguard.py` part 10h) were
**re-aimed, not deleted** - `allocated=False` is now reachable on a mis-routed
claim, an empty envelope set, or sign incoherence, and all three are graded on
real cycles.
* **And the replay that missed it was widened, so the fix is graded rather than
merely applied.** The 250 000-tick replay drew every envelope as
`B(-uniform(0, rating), uniform(0, rating))` - **finite on both ends and
containing zero, every time** - while the check it fed claimed "no share ever
leaves the envelope it was clamped into". The data could only exercise a
symmetric closed interval around zero, so it reported 0 escapes against a live
defect. The generator now draws from **every shape `UnitBounds` can express**:
half-open above, half-open below, intervals that exclude zero, and bare
`UnitBounds()`. Measured A/B against the defective clamp on the same seed and
the same 250 000 ticks: **the old generator sees 0 escapes, the new one sees
39 991.** Reverting the clamp fix under the widened generator takes
`test_alloc.py` red on four checks; re-applying it takes it green. The
collapse is now a row in part 12's mutation table.
* **Known and not closed here:** at a roster of two the loop's `actual_w` is one
inverter's power used as a site measurement, because the add-on binds a single
`inverter_power` sensor. That is the *sensing* half of the same N=1 identity
this card removes from the *commanding* half, and it makes the aggregate trace
split-dependent below `gain: 1.0`. Measured, with the counterfactual, in
`test_alloc.py` part 8 and `tools/alloc_sim.py --splits`. It belongs to
`DEV-02`.
**`Claim` carries the `actuator` specs.md always said it did, and `resolve()`
is three-stage (ARB-03).** `specs.md` §6.1 declares `actuator: str` as the first
field of `Claim`; the shipped `app/arbiter.py` had no such field, so every claim
was implicitly about "the one and only actuator", `resolve()` returned one
scalar, and `main.py` assigned it to one `self.target`. **There was no seam an
allocator could occupy** - and `ARCH-01` decided the site grid target is
ALLOCATED across several inverters and never broadcast. This is a regression fix
against the written design, and it creates that seam. **At N=1 it is a pure
refactor: every one of the 17 suites replays unedited and green, on the same
numbers.**
* **The split, verified at each construction site rather than assumed.** Four
sources are about the **grid connection** and are SITE claims - `loop`
(regulates `grid_w`, the P1 measurement), `peak` (the quarter-hour average
offtake the capacity tariff bills), `arbitrage` (buys and sells at the grid
against a day-ahead price) and `safety` (`stopped` is the site's switch,
`inputs missing` is the site's own meter). Four are about **a pack, a device
or one write** and are PER-INVERTER - `device` (one inverter's own reported
rating), `supervised` (`max_w` caps what may be WRITTEN to one setpoint
entity), `failsafe` (**site-wide evidence, per-unit remedy**: SAFETY-02 grades
the command THIS controller put on THIS actuator, and at N>=2 that evidence
cannot be pinned on a sibling nobody here commands) and `maintenance` (§12's
recalibration is a pack procedure). The reasoning is recorded **at the line**,
in `arbiter.CLAIM_SCOPE` and again at each `claims.append` in `main.py`.
* **Getting it wrong is the parked-battery bug, so it is routed rather than
written.** A per-inverter reserve filed as a site `hi` against the peak guard's
site `lo` is `lo > hi`, arbiter clause 3, **0 W in the billed quarter** -
SAFETY-25 §0a's fatal case. `actuator_for()` is the one routing point and it
**raises `KeyError` on an unclassified source** rather than defaulting to the
site, because defaulting to the site is the failure itself.
* **Three stages, each a function a test can construct a case at.**
`pre_resolve()` turns one inverter's own claims into that unit's interval;
`site_resolve()` turns the site claims into one grid target and **is the
shipped arbiter, unchanged**; `allocate()` is **the seam, and deliberately not
an allocator** - `ALLOC-01` builds it. With at most one unit it passes the
target through (§6.2's N=1 identity); with two or more **it declines, no
shares, `allocated=False`**, because the obvious placeholder - hand the target
to each - IS the fault `ARCH-01` was filed about. **What `main.py` then does
is SUBSTITUTE, not abstain**: it replaces the resolution with a 0 W `failsafe`,
logs "refusing to broadcast the site target", and writes that 0 W through
`write_setpoint()` like any other cycle. The refusal is to BROADCAST; the
write still happens, in the fail-toward-inaction direction. Graded end to end
on a real two-inverter cycle by new **part 10h** - the branch is unreachable
on the shipped roster, and replacing it with `if False:` had left all 17
suites green.
* **`resolve()` HONOURS the roster it is handed, and that is now graded too.**
Left `None` the roster is derived from the claims, which is the documented
default; passed explicitly it is used. Deriving it *always* - ignoring the
argument - makes a unit that filed nothing this cycle cease to exist, so a
site of two reads as a site of one and the seam passes the whole grid target
through to the inverter that spoke: `ARCH-01`'s fault with its own evidence
removed. `test_arbiter.py` part 7 grades it on the one case that separates the
two, a **silent unit**.
* **The contradiction is no longer guarded against, it CANNOT BE WRITTEN DOWN.**
The partition is by `actuator` and it is a partition: a unit's `hi` and the
site's `lo` are never both terms of one `lo > hi` test. Constructed and swept -
40 filings (every per-inverter source x unit x bound, a unit contradicting
ITSELF included) against a live site floor, and not one moves the site target
or raises a contradiction. A unit's own impossible pair parks that unit and
says so on its own bounds; it does not park the site. That is SAFETY-25 §0c's
table made mechanical.
* **At N=1 nothing splits, and that is §6.2's identity rather than the
classification being ignored.** With one inverter the fabricated grid reading
and the battery setpoint are the same number, so the grid connection and the
only unit ARE one actuator and every source routes to the site. **Measured:
dropping that identity - splitting at N=1 - takes `test_peakguard.py`,
`test_freeze.py` and part 10g red**, because the `failsafe` and `maintenance`
SET claims would stop competing for the winner, `explain()` would name a
different source and `loop_is_following()` reads that name.
* **SAFETY-24's floor asymmetry survives, and now has a second half.** The
combination sweep is re-run and still holds - no negative floor, `hi` still
`+inf` on every claim the guard files - and it now also asserts every one of
them is on the **site** actuator, because a floor bound to one inverter's share
would leave the site, the thing the capacity tariff meters, with no floor.
* **The part 10f tripwire is kept and widened, not adapted around.** Its static
AST scan and its dynamic SoC sweep are untouched in substance - `source` is
still `Claim.set()`'s first positional argument precisely so the scan keeps
reading it, which is why `actuator` is the LAST field of `Claim` and not the
first. Its spy gained `**kw` so the roster passes through unread rather than
being silently dropped. New **part 10g** pins `CLAIM_SCOPE` to the same
eight-source set, so a ninth source now goes red twice. Verified by breaking
it: building SAFETY-25's Option B as a ninth source still takes 10f red on the
line it is written.
* **And the CALL SITES are pinned statically, at all eight of them.** 10g's
first cut graded routing only through a **real two-inverter cycle** and called
that "the line a mis-typed `actuator_of(...)` at a call site goes red on".
**It was not.** That cycle reaches `device`, `supervised` and `loop` and
nothing else - three of the eight direct appends - so a mis-type at the other
five survived every suite in this repository. Proved on the shipped tree by PR
#40's reviewer: `actuator_of("maintenance")` -> `actuator_of("peak")` at the
maintenance-shaping append left `test_arbiter.py`, `test_peakguard.py` and
`test_arbitrage.py` all green while, at a roster of two, it built a site loop
of -1500 W against the guard's site `lo` of 1500 W and the now-misrouted
charge-only `hi = 0` - `lo > hi`, arbiter clause 3, **0 W in the billed
quarter**, SAFETY-25 §0a's fatal case from a one-word typo. That is this
repository's named failure mode - **a check observing something other than
what it claimed** - reproduced inside the check written to prevent it, so it
is closed the way 10f closes it: over the **same AST scan**. All eight direct
appends expose their actuator as a literal `actuator=self.actuator_of('...')`,
so the literal is required to EQUAL the source the claim is filed under - all
eight, on the line the typo is written, in every configuration and at every
roster, whether or not any fixture reaches the state that files them.
**Measured: each of the eight mutated to a wrong actuator in turn, each one
red.** The two INDIRECT appends (`peak_claim`, `arb_claim`) carry no
`actuator=` at the call site to mis-type, and are pinned where their routing
is actually chosen - `peakguard.claim()` by the `SWEEP_SITE` sweep,
`arbitrage.claim()` by `test_arbitrage.py`. 10g's dynamic cycle is kept and
now says which three of the eight it sees instead of claiming the class.
**SAFETY-25's open question is ANSWERED: the BMS cut-out is the DELIBERATE and
only backstop for demand-driven discharge, and a loop-side reserve floor is
DEFERRED to `ALLOC-01` rather than rejected (SAFETY-25).** Decided by the
product owner on 2026-09-02. **Option A is the shipped behaviour, so `app/`
changed only where a comment claimed the question was still open** - no
setpoint, no claim, no option, no default moved, and the 17-suite run is green
on the same numbers as before.
* **Why deferring is the safe direction, and it is a property of the shape
rather than a preference.** Option B's proof - `bms_soc_floor <
loop_soc_floor <= peak_soc_floor`, verified through the real arbiter in
`test_peakguard.py` part 10d - has an unstated premise: the reserve predicate
and `discharge_permitted()` read the **same** state of charge. With two packs
they read different numbers. The reserve binds on the emptier pack and files
`hi = 0` while the peak guard, reading the other pack or an average, files
`lo = excess > 0`; `lo > hi` is arbiter clause 3 and the answer is **0 W, the
battery parked in the billed quarter** - the failure the memo itself marks
fatal. **No config-ordering validator can catch it**, because it is a runtime
divergence between two readings and not a config ordering, so CFG-01's shape
of check would pass on the exact tree that parks the battery. Option A's cost
is energy; Option B's cost built too early is a parked battery in the one
quarter of the month that sets the bill.
* **The revisit trigger is recorded explicitly, and it is `ALLOC-01`.** Under
`ARCH-01`'s host-side allocator the two claims stop sharing a list: the loop
floor becomes a **per-inverter `hi` consumed as an interval at stage A**,
while the peak floor stays a **site `lo` at stage B**. Different claim lists,
different stages, **structurally unable to cross** - which is a stronger
argument than the ordering rule, because it makes the crossing unreachable
rather than harmless. That is the shape in which Option B becomes safe to
build, and the memo says so at the point a future reader will look.
* **What will have to be RE-EARNED at N=2 is stated plainly rather than left
for someone to discover.** `SAFETY-27` now names **five floors across two
packs**, so "the SoC" stops being a scalar the config can bound. And
`test_peakguard.py` **part 10f - the pin that made SAFETY-25 mergeable** -
**cannot express two packs**: its dynamic half is a scalar 0-100 % SoC sweep
against a single-series capture, and a two-pack exposure lives in the
*difference* between two readings, which that sweep visits at no resolution.
Its static half (the AST scan pinning the eight claim sources) still bites at
N=2; the dynamic half goes silent. Merging a two-pack reserve on 10f's
current green would be merging on a check that cannot see the failure.
* **The options analysis is kept intact on purpose.** A memo that recorded the
verdict and deleted the reasoning is the failure mode this `DECISIONS/`
directory exists to prevent, so §1-§7 stand exactly as written - including
§5's *"(recommended)"* on Option B and §6's recommendation - with the new §0
saying what was decided and §6 marked as answered. Part 10e's check moved
with the memo: it used to pin the honest `Status: OPEN` line and now pins
that the memo names the option, the date and the trigger **and still carries
both options and the recommendation**.
* **The tripwire stays, and "deferred" is why it stays.** Part 10 and mutation
13 are unchanged in substance: a ninth claim source in `Controller.cycle()`
still takes 10f red on the line it is written. Deferred, not rejected, is
precisely the state in which someone builds Option B by accident.
Operator-facing surfaces follow the decision and nothing else changed on them:
`DOCS.md`'s SAFETY-25 section now says a choice was made and points at the
trigger, and `app/freeze.py`'s finding and `app/peakguard.py`'s point 2 say
"decided, on purpose" where they said "open".
**`PeakStore.record_block()` now has its POLICY ARGUMENT graded, and the
SAFETY-20 import check now looks at all three ways of writing an import
(TEST-13).** Two survivors from TARIFF-01's review, both closed in
`test_tariff.py` only - `app/` is untouched and no shipped behaviour changed.
* **The plumbing of the per-phase reduction was unobservable.** Mutating
`record_block()`'s `billed_w(block, policy)` to `billed_w(block, POLICY_NET)`
left all 17 suites green (+4 B; recorded by TARIFF-01's reviewer, re-run
through the purge harness for TEST-15, and re-run again here). The cause is
the third instance of the same shape as WITNESS-02's span normalisation and
TARIFF-01's own DST window: **a stimulus evaluated where the quantity it
grades is degenerate.** `billed_w()` short-circuits to `block.offtake_avg_w`
whenever `per_phase_offtake_avg_w` is absent, and every block that reached a
store anywhere in the suite was single-phase or built with
`per_phase_offtake_avg_w=None` - so NET, SUM and MAX collapsed onto one
number and the argument could not be seen. Section 7 already owns an
UNBALANCED fixture, `(3000, 500, -200) W`, whose three reductions are 3300 /
3500 / 3000 W; that block is now round-tripped **through the store** under
each policy and read back from both tables. NET is the smallest of the three
here, so a store that quietly billed NET while asked for MAX would
under-record the month's peak - maximum headroom for SAFETY-07, the same
under-guarding direction as the `getattr(..., 0.0)` default SAFETY-07 already
removed from `project()`.
* **The import half of the SAFETY-20 grader made a claim it did not check.** It
collected `ImportFrom.module` only, which is blind to two of Python's three
import spellings: `from . import arbiter as _ab` is an `ImportFrom` whose
`.module` is **None** (the module name is in `.names`), and `import
app.arbiter` is an `ast.Import` node the walk never visited. Both were added
to `app/tariff.py` and the shipped suite stayed **green**. Never a live
exposure - the `_names` half still catches any USE of either alias - but the
printed sentence "it imports nothing from arbiter, clamp or control" was
false for two forms out of three, which is worse than claiming less. The
grader now walks `Import` as well, joins `from . import X` onto its base, and
matches per dotted SEGMENT so `app.arbiter` cannot hide behind a package
prefix while `clamps` / `arbiters` / `controller` are not falsely flagged.
Both graders are also now shown non-vacuous against `main.py`, which really
does import all three modules.
* **Two items on the card were already closed and are struck, not
re-implemented.** `PeakReading.is_observed` is `self.state == OBSERVED`
(`app/tariff.py:266`), already false for `NO_RECORD`; and `project()`'s
`held` read is `max(averager.held_net_w, 0.0)` with **no** `getattr` default,
fixed by SAFETY-07 in 616b62d with a comment naming TEST-13 item 4. Restoring
a default there would re-open a money guard. Removing `clear_partial()` also
stays green and that remains a **PASS**: the `quarter_start` PRIMARY KEY plus
`ON CONFLICT ... WHERE excluded > existing` makes a replay a structural
no-op, which is TARIFF-01's claim rather than a hole in it.
Verified through `tools/mutation_run.sh` (purge, `python3 -B`, tree re-read from
disk, mutated line grepped off disk, byte delta recorded): 7 mutations, all red
on the named checks, plus green baselines before and after and a control run
showing the shipped suite passing every one of them.
**The two `arbitrage()` rungs SAFETY-26's AC4 sweep found pinned from ONE SIDE
ONLY are now pinned from both - and, the actual finding, are pinned so they stop
MASKING EACH OTHER (TEST-16).** `spread == 0.0` weakened to `<= 0.001` survived
the whole suite at +2 B, and `len(firm) < 2` weakened to `< 1` survived at
+0 B - the delta MUTATION.md names as the risky one. Neither was individually
live, and that was the problem: a single firm hour *also* has a spread of zero,
so each rung's failure was absorbed by the other and both could be weakened
together with nothing reporting it. That is invisible to single-mutation
testing, which is how the pair survived four rounds of review on TARIFF-03 and
FCST-03. `test_static_tariff.py` gains section 9, which grades WHICH RUNG
answered each stimulus rather than only whether it refused - the masked case
refuses correctly while reporting the false sentence "the tariff is flat" about
a series that is not flat, so a check asserting only "refused" passes on a
broken tree. The flat rung is swept with small-but-REAL spreads down to
0.000001 EUR/kWh at `min_spread_eur_kwh=0.0` (a value `arbitrage()`'s docstring
documents and its validator accepts on purpose), the firm-pair rung is probed
with a ONE-FIRM-HOUR series and graded on §8.3's sentence coming back rather
than the flat rung's, and a five-row table denies the masking on both sides.
Verified through TEST-15's `tools/mutation_run.sh` unchanged - recursive
`__pycache__` purge, `python3 -B`, tree re-copied from disk between rounds,
mutated line grepped off disk, byte delta printed: 7 mutations plus a green
baseline, 4 of them at +0 B, ALL RED, including both rungs weakened AT ONCE
(5 checks red). **No shipped behaviour changed - both rungs were correct all
along**; `app/` is untouched. `MUTATION.md` gains a section on masking as a
second way a survivor lies, and `test_arbitrage.py`'s SAFETY-26 AC4 note is
marked closed rather than left reading as an open finding.
**`check_output_clamp()` could be moved above `write_setpoint()` in `cycle()`
with test_clamp.py, test_freeze.py and test_loop.py all staying GREEN — the
guard's write-path evidence, `self.clamp_last`, had nothing watching it.**
Measured before the fix, on the move itself: all three suites green. The guard
has two evidence sources and only one of them was covered. `self.loop_clamped`
is set from the `Decision` well above the write, so it survives the move — and
on the §10.3 runaway replay it is the source of every engagement the alarm
reports (0 write-path engagements against 2 loop-side ones), which is precisely
what made the move nearly invisible. `self.clamp_last` is assigned by
`write_setpoint()` and by nothing else (`main.py`), is `None` until it has run,
and is what `engaged_write` reads; moved above the write, that consumer goes
quietly false and a DEVICE-bound clamp — `max_w` above the inverter's own
rating, SAFETY-20's install — stops being reported by anything.
test_clamp.py gains part 6, and it grades the CONSEQUENCE rather than the
position: a spy subclassed from the shipped `ClampWatchdog` records what
`self.clamp_last` held each time the guard consulted it, over a slew-limited
ramp where every cycle's command is a different number, and asserts the
evidence is always the write of THAT cycle. Hooking `clamp_wd.note()` rather
than the guard's name is what keeps a rename legitimate; the same assertions
are re-run through a controller whose guard is renamed and whose write lives in
a helper, and were verified against `main.py` itself — renaming the method
throughout and moving both calls into a new `_emit_and_guard()` helper keeps
part 6 green, while swapping the two calls turns it red on a line that names
`clamp_last`. AC 3 needed a stimulus of its own: through the real `cycle()` the
write-path half can never engage, because the arbiter files the device range
and `max_w` as P_SAFETY LIMIT claims and `resolution.target_w` is already
inside both bounds before `write_setpoint()` re-applies them — that duplication
is deliberate defence in depth, and part 6 now measures the 0 engagements
rather than leaving it as a claim in a comment. So the write path is driven
directly at `max_w` 5000 against a ±2500 W device: the wire carries 2500 W,
every loop-side flag stays clean, and the alarm fires on `clamp_last` alone —
with the two calls swapped, the same stimulus clamps the same value and the
alarm is silent. `main.py` gains one comment sentence pointing at the check,
mirroring the one SAFETY-18's block already carries for test_freeze.py part 5.
**`max_w` and the `LIVE_MAX_W` literal beside it were unpinned in test_freeze.py
and test_tariff.py, the same gap TEST-06 closed one key over for
`meter_freeze_s` (TEST-10).** Measured before the fix: `max_w: 2000 -> 4500`
in `config.yaml` left every check in both files GREEN, and `LIVE_MAX_W = 5000.0`
was a bare literal that silently disagreed with the shipped default (2000) with
nothing saying so — for contrast, `deadband_w: 15 -> 5` already went RED 2 + 1,
so the pinning technique itself was known to work, just not applied here.
Fixed three ways. First, `test_freeze.py` gained a check comparing `Tuning()`'s
code default (`control.py`, 2000.0) against `SHIPPED_MAX_W`, read from
`config.yaml` by extending the file's existing `_cfg_default()` regex reader
rather than reimplementing test_arbitrage.py's `_shipped`. Second, the literal
itself is renamed `LIVE_INSTALL_MAX_W` in both files, with a comment stating
plainly that 5000 is the live install's own override and not config.yaml's
shipped `max_w` — the defect was the silent literal, not the number. Third,
`test_freeze.py` now states `PINNED_KEYS = ("meter_freeze_s", "deadband_w",
"max_w")` in one place as the complete set of config keys this suite pins,
deliberately excluding `maintenance_*` (CFG-03 gave those a separate source of
truth in `app/maintenance.py`). Verified by breaking what the new check
watches: `max_w: 2000 -> 4500` in `config.yaml` now fails exactly
`"the code default and the shipped default agree on max_w too"` and nothing
else, and reverting returns the file to all-green.
**Maintenance option defaults lived in three places that had already disagreed,
and MAINT-04's tripwire was holding them apart rather than closing them
(CFG-03).** `config.yaml` shipped `maintenance_charge_w: 2000`, `main.py` carried
two `opts.get("maintenance_charge_w", 2500)` fallbacks, and `MaintConfig`'s
dataclass carried a third `2500.0`. An options dict with the key **absent** was
therefore accepted by `validate.py`'s rule 6 — which read 2000 — and then built
by `main.py` at 2500, against a 2000 W ceiling. Demonstrated through the shipped
code:
options dict with maintenance_charge_w ABSENT, max_w=2000
validate_startup_config -> [] (ACCEPTED, no problems)
MaintConfig().charge_w -> 2500.0
arbiter.resolve() -> 0.0 W, contradiction=True
That is the bug rule 6 exists to refuse, **passing rule 6**. Unreachable through
the Supervisor, which always supplies every key from `config.yaml`; fully
reachable from `sim/inject.py` and from the test suite, which is where anyone
debugging maintenance is.
**`maintenance_discharge_w` had the identical divergence** (`config.yaml` 2000,
`MaintConfig` 2500) and the card named only the charge side. Closing one key and
leaving its twin would have reproduced the defect one line down, so both are
closed.
**The single source of truth is `config.yaml`'s `options:` block** — the file the
Supervisor reads and the operator edits. There is now exactly **one** in-code
copy, `maintenance.MAINT_OPTION_DEFAULTS`, which is TARIFF-02's
`PRICE_OPTION_DEFAULTS` and SAFETY-24's `PEAK_OPTION_DEFAULTS` pattern applied to
the family that named the card. A mirror rather than a runtime read because the
`Dockerfile` copies `app/` and `run.sh` into the image and **not** `config.yaml`:
the running add-on cannot open the file it is configured by. `test_maintenance.py`
pins every entry by **reading** the shipped file, so a drift is a CI failure
rather than a comment. Every other declaration site now derives from it or has
ceased to exist:
- `MaintConfig`'s eight dataclass defaults are indexed out of the mirror — no
numeric literal survives in the class that held the third opinion;
- `MaintConfig.from_options()` is the **only** place in the add-on that reads a
`maintenance_*` option. `main.py`'s eight inline `opts.get(key, <literal>)`
calls are gone;
- `main.py`'s second fallback site (the cheap-window charge floor) reads
`self.maint.cfg.charge_w` instead of re-opening the options dict, so the rate
the shaping asks for and the rate the state machine drains at cannot be two
numbers from one install;
- `validate.py`'s rule 6 and its `maintenance_discharge_w` warning take their
fallbacks from the mirror.
**Where the RANGE lives is now stated and checked, so the next person does not
add a fifth site.** `maintenance_charge_w: int(500,5000)` in `config.yaml`'s
`schema:` block is a fourth declaration of a different kind — a bound, not a
default. Bounds live in the schema block **only**: the Supervisor enforces them
and reads only that file. `test_maintenance.py` asserts that every mirrored key
has a schema entry (or the Supervisor silently drops the option and the add-on
runs on the mirror instead of the operator's value) and that every shipped
default lies **inside** its own range. What the schema grammar cannot express is
a relation *between* keys — `maintenance_charge_w` against `max_w` — which is
why rule 6 is written in Python and does not belong in the mirror either.
**MAINT-04's tripwire in `test_validate.py` is DELETED, not left passing**, as it
and `validate.py`'s ⚠️ block both instructed each other to do. Its passing
condition *was* the bug. In its place, the same four consumers exercised the same
way and now agreeing: the validator accepts a dict with every `maintenance_*` key
missing, a **real `Controller`** built from that dict holds 2000 W, `MaintConfig()`
answers 2000 W with no dict at all, and the real arbiter emits `-2000 W, limited
by supervised(max_w)` instead of `0 W, contradiction=True`.
**Checked by breaking it, five ways, each observed red before being reverted:**
move `config.yaml` alone → the mirror pin fails; move `config.yaml` **and** the
mirror to 1500 → every consumer follows together (`MaintConfig()` 1500 W, the
`Controller` 1500 W, the arbiter `-1500 W, limited by maintenance(cheap-window
charge)`) and both suites go green again; retype `charge_w: float = 2500.0` into
the dataclass → red; restore `opts.get("maintenance_charge_w", 2500)` in
`main.py` → red; delete a key from `config.yaml`'s options block → red.
Stale prose that asserted the closed divergence as current is corrected in
`app/watchdog.py`, `test_watchdog.py` and `test_peakguard.py`.
**`peak_soc_floor` reads like a pack-wide reserve and is not one, and on a
sustained-load evening the grid-following loop discharges straight past it to
the BMS cut-out (SAFETY-25).** The gap has been written down four times without
being filed — SAFETY-18's finding (`freeze.py`), SAFETY-24's module note, its PR
body, and its honestly-uncaught 13th mutation — and never once measured. It is
measured now, on the committed 2026-08-20 capture, driving the shipped
`control.compute()`, `peakguard.decide()`, `peakguard.claim()` and the real
`arbiter.resolve()`:
19:00-22:00 UTC, 830 W mean, minimum 701 W, not one watt of export
reference pack (300 Ah x 51.2 V x DoD 90) started at 21 %, one point
above peak_soc_floor
ends at 10.0 % - the bms_soc_floor cut-out
1525 Wh delivered by the LOOP over 587 cycles
549 cycles below peak_soc_floor, 343 of them still discharging
0 cycles on which the peak guard filed any floor at all
**And it is a behaviour, not a config value.** The same evening ends at
`9.9715 %` at `peak_soc_floor` = 5, 11, 20 **and** 60 — the shipped value and
both ends of the schema range — identical to four decimal places. The option an
operator would reach for cannot move the number by any amount. On the same day's
high-load block the two states coexist: 49 cycles reporting `PEAK GUARD
FLOOR-LIMITED` and, on **all 49**, the arbiter simultaneously granting the loop
up to 2000 W of discharge.
**Why SAFETY-24 could not close it.** The peak guard files a `lo` limit — a
*lower* bound. That asymmetry is what makes it provably unable to lower a target,
cap a discharge or contradict the arbiter, and it is therefore equally unable to
stop a discharge the loop itself wants. A floor on the guard cannot become a
floor on the pack by being raised.
**What changed is the honesty, on four operator-facing surfaces**, because that
half is required whichever way the open question is answered and it is the actual
misstatement on the live system today:
- `config.yaml` says next to the option that it **bounds the peak guard only** and
is **not a pack-wide reserve**, with the replayed evening and the sweep;
- `DOCS.md` says it in the options table and in a new section carrying the
figures above;
- the **status-page row** for a floor-limited guard carries the scope sentence —
it is the one line a human reads at the moment the guard stops, and read alone
it implies a reserve the replay shows does not exist;
- the **persistent notification** says what has stopped (the guard buying a lower
bill) and what has not (the pack being spent).
`peakguard.py` and `freeze.py` carry the measurement beside the findings they
already recorded.
**The product decision is NOT taken here.** Whether the loop gets a reserve floor
of its own moves real energy on this house and belongs to the owner.
`DECISIONS/SAFETY-25-loop-soc-floor.md` records the options, what each costs and
protects, weighed against MAINT-01 and against the fact that this would be the
**fifth** SoC key (OPT-04's `arbitrage_soc_floor` fired SAFETY-24's "revisit if a
third floor appears" trigger unremarked), and a recommendation. It also records a
trap found while writing it and now checked through the real arbiter: the obvious
shape — a `hi` limit on the loop — crosses the peak guard's `lo` and resolves to a
**CONTRADICTION at 0 W**, the battery parked in the quarter that sets the bill,
unless `bms_soc_floor < loop_soc_floor <= peak_soc_floor` is enforced at startup.
**`test_peakguard.py` part 10 is a tripwire, not a guarantee, and part 10f is
what makes it one.** The replay half records the defect; on its own it could not
see the defect being FIXED, because `replay_loop()` hand-builds main.py's claim
list and is therefore blind to any claim main.py adds — which is exactly where a
loop-side floor would be built. PR #31's reviewer proved that by building the
memo's own Option B in `main.py` and watching the whole suite stay green. **10f
pins the claim-source set:** every `claims.append(...)` in `Controller.cycle()`
is read off its AST and must be one of eight named sources, and real
`Controller.cycle()`s — spied at main.py's own `resolve`, swept over the whole
0–100 % state-of-charge range in both the idle and the floor-limited state — must
hand the arbiter exactly `{device, supervised, loop}` and
`{device, supervised, loop, peak}`. A ninth source, at any state of charge, in
any configuration, takes part 10 red on the line it is written. A floor built
inside `control.compute()` or the guard instead moves 10a–10c's replayed numbers,
which the replay drives directly. So the exposure cannot change size under a
green suite.
**Nine mutations, re-run against the fixed tree**, each against a freshly copied
tree with no `__pycache__` present at all, mounted `:ro` — the same structural
immunity `MUTATION.md` records for CI. Six are the AC 3 and behaviour mutations
already on this ticket's record (the status row's scope sentence, the
notification's, `config.yaml`'s, the memo deleted, the loop's gain zeroed, the
guard's claim given a `hi`); two are the reviewer's, and are the ones that
motivated 10f — the memo's own Option B at its recommended default, **now three
checks red where it was fully green**, and an absurd always-binding 95 % reserve,
**six red**; one is new, against the banner short form below. All nine are red,
no survivors, and no byte delta is `+0 B`.
**The gate has never once graded the content a pull request would land, and a
run that never started reported as a test failure (CI-02).** Both halves were
measured on a deliberately conflicted throwaway pull request rather than read
off the workflow, because the Actions log endpoints 404 on this Gitea and a
step's own conclusion is the only channel out of a job.
**Case 1, and the ticket's mechanism was wrong in a way that made it worse.**
CI-02 was filed saying a conflicted pull request loses its merge ref, so that
`git fetch $GITHUB_REF || git fetch $GITHUB_SHA` falls through and grades the
bare branch head. The symptom was real — PR #14 reported `checks / unit ->
success` while `mergeable: false` — but the mechanism is not. On this server
`GITHUB_REF` **is** `refs/pull/<n>/head`, `GITHUB_SHA` is the same commit, and
`git ls-remote origin 'refs/pull/*'` advertises no `/merge` refs at all, for
open and closed pull requests alike. The first fetch has always succeeded; **the
fallback has never fired once.** So the gate did not lose merged content on
conflicted pull requests — it has never had merged content, on any pull request
in this repository's history. Green has meant "this branch passed on its own",
which on a base that has moved is not what lands, and `block_on_outdated_branch`
is off on release/1.0 so the base usually has moved.
**The checkout now fetches the base tip and the pull request head, merges them,
and refuses if the merge does not apply** — as its own named step, so
`/actions/runs/<id>/jobs` distinguishes "nothing was tested" from "the tests
spoke". Verified by producing it: with the fix on a conflicted pull request the
required context went `failure` in 2 s with the two test steps `skipped`. The
`--depth 1` is gone (a merge needs a merge base; a full fetch of this repository
is 6.8 MB and 1.1 s), and the fallback survives only on the `workflow_dispatch`
path, which has no pull request to merge and now says so in its output.
**Case 2: `concurrency:` is gone, and `cancel-in-progress` was never the knob.**
Runs 531 and 533 on PR #14 were cancelled at 0 s each at the exact second the
next run was created, having never started; a cancelled run posts `failure` on
the required context, described `Canceled after 0s`, and branch protection
compares state and not description — so "nothing ran" and "your tests are
broken" arrive at the gate as the same red, wanting opposite responses. Three
settings were measured with one run holding the single runner slot and two
pushes behind it: with **no block at all** both queued runs survived and
executed; with the group kept and **`cancel-in-progress: false`** the queued run
was still cancelled at 0 s. A shared group cancels a run that has not started
regardless of that flag. Having no group is the only configuration measured to
leave a queued run alive, and it is what ships. The cost — a developer who
pushes four times occupies the shared runner four times — is CI-01's own trade
written the other way round: a delayed verdict, never a destroyed one.
**`test_ci_gate.py` grades the gate by running it, not by reading it.** It
extracts the checkout and merge steps out of `checks.yml` and executes the
shipped commands against two throwaway local repositories it builds — one whose
pull request merges, one whose does not — and pins that the old one-liner exits
0 on the unmergeable one while the new steps refuse. It also pins the two tokens
that assemble `checks / unit (pull_request)`: renaming `name:` or the `unit:`
job key would leave every open and future pull request waiting forever on a
context that never arrives, with no error anywhere in that sequence. Seven
mutations of `checks.yml` were each confirmed red. `.gitea/ci/Dockerfile` gains
`git` for it.
**What was NOT established, stated so nobody reads more into this.** The
original report that "no run was ever created for `0942228d`" was already
corrected on the card — run 533 was created and cancelled — and this work
confirms that from the runs list and the per-commit status history. A commit
that never had a run carries an empty `/statuses/<sha>` list; a queued one
carries `pending / Waiting to run` within seconds, and a concurrency-held one
`pending / Blocked by required conditions`. Those are distinguishable at the
API. `/actions/tasks`, which is what was polled originally, lists only tasks
that started, and cannot answer the question at all.
**The NOT READY banner no longer repeats the row underneath it.**
`status_payload()` renders the first hard-failing check as the page headline, so
the scope sentence above turned the loudest element on the page into a
550-character paragraph that the checks list then repeated verbatim. A row may
now carry an optional short `banner` form; the floor-limited row does, and its
headline is the guard's own line plus a 68-character scope tag. **The row itself
is unchanged** — the checks list is where an operator reads what the floor does
and does not bound, and shortening that would have been weakening AC 3. Rows
without the key are unaffected, and the page still renders with `textContent`.
**A setpoint device smaller than `max_w` silently disarmed the frozen-meter
detector, and the status page reported it as armed (SAFETY-20).** SAFETY-18's
conjunction needs `abs(commanded_w) >= 0.95 * max_w`, but the emitted command is
clipped to the setpoint device's own `[dev_min, dev_max]` range as well as to
`max_w` — in `clamp_to_rating()` and again as the arbiter's `device` P_SAFETY
limit claim. Measured on the shipped predicate at the ticket's numbers,
`max_w: 5000` on a ±4700 W inverter:
looks_frozen(unchanged_s=3600, commanded_w=4700, max_w=5000) -> False
The command is pinned at the hardware's rail, the meter has been frozen for an
hour, and term 2 is unsatisfiable by construction because 4700 < 4750. Any
rating at or below `0.95 * max_w` disarms the conjunction outright. The page
then printed `armed (… command is over 4750 W)` — a guard that cannot fire,
advertising that it can, which is the failure SAFETY-15, SAFETY-19 and
validate.py rule 5 all exist to prevent.
**The rail is now measured against `min(max_w, |dev_min|, |dev_max|)`** —
`freeze.rail_ceiling_w()`, threaded through `looks_frozen()`,
`FreezeWatchdog.evaluate()` and both call sites in `main.py`. An unread rating
(`hass.limits()` returning `None` when ESPHome is not up) leaves the old
behaviour exactly, and correctly: on that path no device clamp is applied
either, so `max_w` really is the ceiling. A rating *larger* than `max_w` cannot
raise the rail — this is a `min()`, not a swap. The status row prints the rail
the predicate actually uses and names the device when the device is what capped
it; the log line and the HA notification do the same, since they outlive the
page.
**The smaller of the two device bounds, not a per-sign pair.** A per-sign rail
is tighter and is not wrong, but it is two rails needing two coverage verdicts
on a status row that carries one number, and the only configuration that
distinguishes them is refused at startup anyway. The symmetric ceiling can only
*lower* the rail, which widens term 2 rather than disarming it; term 1 carries
the no-false-positive argument and is untouched.
**A ceiling of 0 W is NOT COVERED, not "armed at 0 W".** A device that can
command nothing in one direction would make `abs(command) >= 0` true of every
command including a parked one — term 2 degenerately *true*, collapsing the
conjunction into the bare `unchanged_s > N` threshold TEL-05 refused for
false-tripping at this controller's own operating point. `rail_unreachable()`
returns the reason, `looks_frozen()` stays silent, and the page uses the NOT
COVERED row the unsupported-transport case already has — a second reason to use
that surface, not a new mechanism.
**AC4, decided rather than assumed: no new `validate.py` rule.** The
configuration is `max_w` above the device rating, which rule 2 (CFG-01) already
refuses on the identical predicate, re-run by `run_control()` once the real
rating is known. A rail-specific rule would fire on a strict subset of what rule
2 refuses (`0.95 * max_w > dev_max` implies `max_w > dev_max`) and could never
be the rule that stopped a start. The residue is the state where `hass.limits()`
answered `(None, None)` and the range checks were skipped — there is nothing to
refuse there, by construction, which is why the answer is a runtime row. Written
into validate.py's "deliberately not refused" list, and *pinned* by four checks
in `test_validate.py` so the decision's premise goes red if rule 2 is ever
softened back to a warning.
**And it was verified by breaking it.** Reverting `rail_w()` to bare `max_w`
fails nine checks; deleting the NOT COVERED handling fails five; and — the one
that mattered — shipping the corrected predicate while *not* passing the rating
from `check_meter_frozen()` originally left the whole suite green, because
nothing graded the caller. `test_freeze.py` part 5b now drives the real
`cycle()` on a ±4700 W device and asserts on the notification that leaves the
process; the unwiring mutation fails three checks there. The peak-guard call
site's wiring is still ungraded — it sits behind `p1_enabled` and needs a fed
averager to have any observable consequence — and that gap is named in the file
rather than implied.
**A mutation run could grade code that was not there, and the fix is a purge
rather than a flag (TEST-15).** FCST-03's developer reverted `self.provisional`
to `here.provisional`, re-ran, and reported a survivor; disassembly showed the
source read `here` while the running code loaded `self`. CPython validates a
`.pyc` on (source size, source mtime truncated to whole seconds), and a
size-preserving edit reverted inside one second moves neither number, so the
stale bytecode was reused. That does not make past results wrong - it made them
unverified, and the distinction is the whole card.
Reproduced rather than reasoned about. `test_bytecode.py` builds a real package
whose two return values are the same length, imports it in a real subprocess,
rewrites it inside the same second and reads back which value ran. Part 1 shows
the interpreter running `SELF` off a file that says `HERE`.
**And it shows the two obvious mitigations do not work.** `python3 -B` and
`PYTHONDONTWRITEBYTECODE=1` are write-side only: neither stops an EXISTING stale
`.pyc` being read, and a mutation run always has one because the previous run
wrote it. The advice already in `test_control.py`'s coverage audit led with `-B`
and is corrected here - the purge is the half that works, and `-B` earns its
place by protecting the NEXT edit rather than this one. No `sleep` anywhere:
one-second mtime resolution is the mechanism, and waiting it out would slow every
run down while still only covering the edit somebody remembered to slow.
`goodwe_controller/tools/mutation_run.sh` is the harness the house adopts: it
purges, prints a sha256/byte fingerprint of every `app/*.py` it is about to
grade - so a mutation report can say WHICH source produced it - runs each suite
under `python3 -B`, refuses a tree with no `test_*.py` (CI-01's rule), and fails
if a cache appears during the run. It takes the tree as an argument so the infra
repo's replay harnesses can call it.
`MUTATION.md` states the guarantee where a mutation gets written, and every one
of the 16 suites now points at it from its docstring - a list `test_bytecode.py`
derives from the tree, so a new suite joining without the pointer is red.
CI was already immune and is described that way rather than as a hole being
closed: `checks.yml` mounts the checkout `-v "$WS:/w:ro"`, and a read-only tree
cannot take a `__pycache__` at all - measured, and it fails silently, exit
status 0 - while each job `rm -rf`s its workspace and clones afresh.
`PYTHONDONTWRITEBYTECODE=1` is added as belt and braces, because the `:ro` is one
character wide. The shipped add-on was never affected: `Dockerfile` has set
`PYTHONDONTWRITEBYTECODE=1` since it was written.
**The survey of this week's mutation claims is in `MUTATION.md`, scoped by the
property rather than by re-running everything.** The defect is one-directional -
stale bytecode turns a red into a green survivor and never the reverse - so every
"all red, no survivors" result in the window is not at risk, and the exposure is
the recorded SURVIVORS from source-edit runs made before the purge discipline
landed on 2026-08-31. Two of them were re-run here under the harness and both
still stand (TARIFF-01's `record_block()` ignoring its `policy` argument;
SAFETY-03's `abs()` on the clamp limit). The rest are labelled still-unverified
rather than quietly assumed or noisily re-run.
Out of scope and recorded: the infra repo's `sim/` replay harnesses import the
add-on and write bytecode into both trees. Anyone mutating a module graded by a
replay must purge both by hand until that repo adopts the harness.
**`release/1.0` went red at midnight on a commit nobody had touched (TEST-17).**
`Controller.checks()` read the capacity-tariff peak with `self.peak.peak()` - no
argument - so `tariff.py` resolved the month from `datetime.now()`, while
`test_tariff.py` section 10 banks its quarter at the fixed fixture
`2026-08-30`. From 1 September the page was correctly asked for September,
correctly answered `NO_RECORD`, and the row read *"no completed quarter recorded
yet"* - a string containing no `"peak"`, which the section's filter required.
Four checks failed. The suite had been a latent time bomb since TARIFF-01
merged on 2026-08-30 and every PR that ran it ran in August.
Isolated by holding the commit and the image constant and moving only the clock
under `libfaketime`: green at 2026-08-30, four failures at 2026-09-01, identical
at `f4914a1`, `04292c4~1` and `04292c4`. The calendar, not a regression.
**The product was right and the test was wrong**, so the fix does not change what
the live page says. `checks()` takes `when: datetime | None = None` and threads
it into `peak()` and `warning_frac()` - the convention every other peak query in
`tariff.py` already follows. The single production caller passes nothing and
still means today. Section 10 now grades at its own fixture's month.
Three new checks make the defect detectable rather than seasonal: the same
controller read at two different reference months must produce two different
rows, which no clock can satisfy; the later month must read `NO_RECORD` and stay
distinguishable from both an observed peak and an unreadable store; and calling
`checks()` with no argument must still mean today. Verified by mutation - a
`checks()` that drops `when` is now red at every clock tried, where the old
section went green in August. Full suite green, 15 files, at the real clock and
at faked clocks in four other months.
One thing left alone deliberately: only the UNREADABLE branch prefixes its row
with `capacity-tariff peak:`. The `NO_RECORD` row carries neither that phrase
nor the word `peak`, which is what made the original filter brittle and what
broke the first draft of the new checks too. It is product text with other
suites reading it, so it is noted here rather than changed.
**Thirty days of the real meter, and the acceptance criterion three cards
deferred is now a number (DATA-01).** TARIFF-01 and SAFETY-07 both merged with
AC 3 - *"monthly peak held under the soft limit in >= 95 % of intervals over a
30-day simulation replay"* - honestly unmet, on the belief that only two days of
capture existed and nothing longer could be produced. That belief came from a
true statement about the past being read as one about the future: HA's recorder
still held the whole month. `scenarios/p1-net-30d-2026-08/` is 2026-08-01 to
2026-08-30, **485,841 samples, 30/30 days read, 0 failed, 4.13 MB gzipped**, in
the same schema as the two days that were already there.
`tools/export_p1_history.py` is the exporter, committed and runnable - the
2026-08-25 one-off was not, and that is exactly why the data was thought
unobtainable. It reads day-at-a-time, retries, and **never lets a failed read
look like an empty hour**: a day whose read fails writes no file, is recorded as
`"read": "FAILED"`, and the run exits non-zero; the entity is proved to exist
before any empty day is believed. Nothing is interpolated, so the month's 13
gaps (1291 s, 99.95 % covered) and its 3 `unavailable` samples stay visible.
`--verify` re-fetches the two committed days by the same route and reproduces
them **byte for byte** after decompression.
`tools/replay_ac3.py` runs the month. Over 30 days the criterion measures
**98.89 % uncontrolled and 98.99 % guarded**, so it is met on that reading - and
the uncontrolled figure is the finding: a month with no controller at all passes
it. On the other reading of the same sentence it is not met - the guard takes
August's peak from **5029.8 W to 4107.3 W**, still over the 3500 W soft limit,
because once a month peak is set `CEILING_MONTH_PEAK` defends that peak rather
than the cap. Neither number is hidden; both are in that directory's README.
The size decision is committed and measured, not absorbed: a `git bundle` of
the whole history goes from **1.58 MB to 5.28 MB** (+3.70 MB, x3.3), which a
Home Assistant supervisor clones on every install. Downsampling was not
available - `meter_max_age_s` is 30 s, so any coarser resample converts real
coverage into modelled meter-gap and moves the number being measured.
The thirty files sit in a SUBDIRECTORY on purpose: `test_tariff.py` part 9 and
`test_peakguard.py` part 6 glob `scenarios/p1-net-*.jsonl.gz` non-recursively,
so CI keeps replaying the two small days and does not grow ~50 s per PR. Both
files' honesty notes are corrected to point at the month.
**OPT-04's AC4 is met: twelve months of real EPEX BE day-ahead prices are now in
the repository, and the strategy has been replayed against them (DATA-02).**
AC4 asked for "net-positive across 12 months of replayed prices". OPT-04 shipped
it as NOT MET and replayed a synthetic year instead, because `scenarios/` held
only P1 meter captures. That was the right call at the time and the wrong
diagnosis of why: the criterion was being carried alongside a 30-day *meter*
criterion as though both needed waiting, and EPEX BE day-ahead is **public data,
not a capture**. It needed a fetch, not a month.
`scenarios/epex-be-dayahead-2025-09-01_2026-09-01.json` — **8760 hourly points**,
2025-09-01 to 2026-09-01 Brussels-local, in §9.3's canonical three-field shape.
`scenarios/fetch_epex_be.py` produced it and `--verify` re-derives every claim it
makes about itself without touching the network.
**Licensing was checked before anything was committed.** The source is
Fraunhofer ISE's Energy-Charts API, which publishes the **BE** zone under
**CC BY 4.0 from Bundesnetzagentur | SMARD.de** and other zones under
private-use-only terms — so this zone is redistributable with attribution and the
data is committed rather than left as a script plus a checksum. The fetcher
**refuses to write a file** whose per-response `license_info` stops saying
CC BY 4.0. Cross-checked against the upstream: SMARD's own `4996/DE` series
matched this feed on all 96 quarter-hours of 2026-04-10, maximum difference
0.00 EUR/MWh.
**The figures are raw wholesale and the file says so.** `"all_in": false`, with
the markup/tax assumption carried in `provenance.all_in_assumption` as *numbers
to apply* rather than numbers already applied — TARIFF-02's double-counting trap
in data form. `test_arbitrage.py` section 7B applies it in one visible place and
**asserts arithmetically** that its two additive terms cancel out of every daily
spread, so the trade counts depend on the VAT multiplier alone and not on the
guessed markup. The same replay is run on raw wholesale as well, so how much of
the answer rests on the guess is reported (110 trades all-in, 88 raw).
**DST is handled by construction, not by a special case.** The fetcher iterates
in UTC and renders through `price.brussels()`, so **2025-10-26 comes out 25
points and 2026-03-29 comes out 23** — verified by counting per Brussels day
rather than asserting 24, and by checking that October's 02:00 appears twice at
`+02:00` and `+01:00` with two different prices while March's 02:00 does not
appear at all. The window is bounded at *local* midnight: bounding it at 00:00
UTC produced a 22-hour first day, and a 24-hour day silently missing from the
end, both of which the point-and-gap accounting caught.
**The result, at the shipped default, whatever it is.** At
`cycle_cost_threshold_eur` **0.10** widened by FCST-03's no-weather **1.5×** to a
required 0.1500 EUR/kWh, the real year completes **110 round trips** and is
**net-positive at +24.88 EUR** of benefit net of the cycle cost (2 kWh a trade).
Unwidened it completes 173. **Nothing was tuned:** the shipped default and the
2.5/1.5 factors are untouched, and every figure comes out of the same `decide()`.
**What the product owner's open decision now has under it.** The four
independent reports that a static day/night spread of ~0.0840 does not clear
0.10 **all stand** — a static-tariff site still never trades. What was missing
was the other half: a *dynamic* site's daily spread clears the widened
requirement on **121 of 365 days**, median daily all-in spread **0.1130**. The
threshold at which a median day would clear is **0.0754**, and at that value the
same year completes 156 trips for +35.42 EUR. Both numbers are reported; neither
is applied.
**And the synthetic year stays, because the real one cannot grade §17.** Not one
of the 365 real days has a negative *dearest* hour — 372 negative wholesale hours
and 0 days where the strategy would have sold into one — so "0 discharges into a
negative-price hour" over real prices is a count of something that could not
happen, and deleting the guard would not change it. Section 7B asserts that
degeneracy instead of quietly reporting the zero; section 7's generator is still
the only thing here that puts a negative price where the strategy would sell.
**Size, measured rather than assumed.** Plain JSON: 893 KB in the working tree
but **74.6 KB as a git object**, against 56.5 KB for a committed `.json.gz`. Git
already compresses blobs, so gzipping saves 18 KB and costs a reviewer the
ability to read the provenance block — including the licence claim they are
meant to check — in the diff. Plain, and `load()` still accepts `.gz` for a
future dataset that earns it.
**Nothing is wired into the add-on.** `generic_dayahead` remains the live fetch
path; nothing under `app/` imports the script, and the dataset is for replay.
**The capacity-peak guard's forced discharge now has an EMS-side energy floor
(SAFETY-24).** SAFETY-07 can command a discharge to hold a billed quarter down,
and nothing below it consulted the state of charge — `soc_floor` belongs to the
maintenance cycle, and freeze.py already recorded that for the grid-following
loop "the BMS is the sole energy backstop". On the 2026-08-20 replay the guard
asks for **878 Wh in a day**. Relying on the BMS is not absurd — it is a real
floor and it works — but it is the pack's protection rather than the operator's,
and a month of aggressive quarters leaves the battery repeatedly at that cut-out
with no EMS-side record of why.
`decide()` now takes `soc` and `soc_floor`, both **required** and neither
defaulted. Above the floor nothing changes. At or below it the guard files a
**0 W** floor instead of a sized one — one-directional, so charging stays blocked
and no discharge is capped — and reports `floor_limited` with the reason it
bound. It is not a trip: every stop in §11.2's table still outranks the claim,
and the floor can never be negative, so §9.1's "discharge and export are never
capped by the peak guard" survives as a property of the object (swept: 0 negative
floors across 1296 combinations of load, elapsed, battery, SoC and floor).
**Failing to shave is not silent.** A floor-limited cycle raises one notification
per episode (`goodwe_peak_soc_floor`), distinct from the saturation alarm because
the two ask the operator for opposite things, and renders its own status row.
An **unreadable SoC is floor-limited, not a full battery** — a full battery is
exactly the value that would disarm the floor, and this project has shipped that
defaulting once before (`| float(100)` in the stage-5 loop).
**Verified by replay, not by argument.** The 2026-08-20 capture is driven against
a modelled pack sized from the day's own measured appetite, so it genuinely
exhausts: without the floor it reaches the BMS cut-out and sits there for 1227
guard cycles; with it the pack stops at 20.0 % and never touches the BMS. The
energy withheld equals the energy between the two floors to within one cycle at
the rail. The honest half is reported too — the worst quarter goes from 4338 W to
5030 W, because a floor-limited guard shaves less on purpose.
**Two new options, mirrored once.** `peak_soc_floor` (20) and `bms_soc_floor`
(10), whose defaults live in `peakguard.PEAK_OPTION_DEFAULTS` — TARIFF-02's
pattern — imported by `validate.py` and `main.py` rather than typed as literals,
and pinned to `config.yaml` by a check that reads the file. CFG-03 still tracks
three places. `validate.py` rule 8 refuses `peak_soc_floor <= bms_soc_floor` at
startup, in CFG-01/MAINT-04's manner. `maintenance_soc_floor` is deliberately
**not** reused and deliberately **not** renamed: it is a drain target, not a
spend limit, and the rename is recorded as a decision to revisit if a third
floor ever appears.
**Price arbitrage - the first strategy that trades on a price (OPT-04).**
Four cards built the price stack and nothing traded on it. `app/arbitrage.py`
is §10.1's priority 3: charge in the cheapest published hour, discharge in the
dearest, **and only when the spread covers `cycle_cost_threshold_eur`**. It is
off by default (`arbitrage_enabled: false`) - it is the first strategy in this
add-on that commands the battery against the meter on purpose.
**It consumes the four cards rather than re-deciding anything.** Whether a
trade is permitted at all, on which two hours, and against which widened
threshold is `TariffPlan.arbitrage()`'s answer (TARIFF-03), and that answer
cannot be obtained without first stating whether the peak guard is holding. So
§9.1's "give peak shaving priority over arbitrage" is honoured
**structurally**: there is no code path to a tradeable spread that skips the
question. And because the claim is filed at `P_ARBITRAGE` (30) while peakguard
files its floor at `P_PEAK` (50), the arbiter clamps an arbitrage charge even
if that interlock were bypassed. Two independent mechanisms, neither
re-implemented here.
**A guard that never ran is not a guard that is clear.** On `meter_source: off`
there is no telegram stream, so the peak guard is never evaluated. That third
state is carried as `None` and it **refuses**: charging at the rail creates the
billed quantity while nothing measures the quarter it lands in. `validate.py`
refuses that configuration at startup too, along with arbitrage armed on a site
with no price source at all, and a SoC floor at or above the ceiling.
**§17: never export into a negative price.** The guard is on the hour being
sold into, not on the spread - a day priced -0.30 ... -0.05 has a 0.25 EUR/kWh
spread that clears any shipped threshold and a dearest hour that is still
negative. Buying in a negative hour stays allowed; being paid to charge is the
right trade.
**Prices are fetched in the background, never on the tick.** `resolve_tariff()`
may open an HTTPS connection, and the control tick is what feeds the ESP32
heartbeat - a supplier's TLS timeout there is a supplier able to push the
add-on towards layer 1's 30 s veto. A separate task refreshes every 30 minutes;
the tick reads an attribute and an age bound, and a plan whose refresh has
stopped answering retires rather than standing as if it were current.
**What is honestly not measured.** The acceptance criterion asked for
net-positivity across 12 months of *replayed* prices. This repository holds no
price history - `scenarios/` is P1 meter data - so that criterion is **not met,
and is not restated**. What `test_arbitrage.py` section 7 does instead is
replay a synthetic year and assert the property that does not need real prices:
every executed round trip cleared its own widened requirement, on all of them,
across a year containing 522 hours priced below zero and zero discharges into
one. And at the shipped 0.10 EUR/kWh threshold a realistic Belgian day/night
site **does not trade at all** - reported, not tuned. That number, and the
widening factors beside it, are one product decision and it is open.
**Provisional prices, and what may not rest on one (FCST-03).**
Day-ahead prices arrive once a day, around 14–16 h CET. Until they do, §8.3 says
the unknown hours use yesterday's profile and are flagged `provisional: true` —
and **no irreversible action may be taken on a provisional price.**
`app/price_forecast.py` does the fill, and the whole module is shaped by one
defect: a carried-forward point and a published one are the same three fields
and a bool, so the natural line `PricePoint(..., provisional=y.provisional)`
copies yesterday's `False` onto today's guess and produces stale data presented
as current. That is the meter-side SAFETY-18 failure one layer up — the reading
arrives on time, looks fresh, and is wrong.
**So the flag is never passed through.** Carried points are built by a
constructor that has no `provisional` parameter at all (the literal `True` lives
in one place, and there is nothing for a caller to forget or copy); published
points are passed through **by identity**, so there is no copy that could lose a
flag; and an audit re-derives the expected flag for every emitted point from the
set of hours the feed actually published and *raises* rather than repairing one.
A published point may itself be provisional — `eneco_eddy`'s current-quarter
imbalance print is — so the audit's rule for a published hour is "whatever the
feed said", never "False".
**The fill keys on the Brussels wall clock, not on `t − 24 h`.** A 23-hour day
has no 02:00 and a 25-hour day has two, so a fixed 24-hour subtraction shifts
every carried hour by one across a transition and misprices a whole day with
nothing to show for it. Re-running the fill after a late publication replaces
the carried hours with the real print: the number and the flag move together
because the series is rebuilt, never patched.
**Arbitrage now drops provisional hours instead of refusing the whole day.**
The refusal that read "the plan is provisional" would have switched arbitrage off
every morning on every dynamic site once carry-forward filling landed — a
part-firm series is the *normal* state before the print. What §8.3 forbids is
acting **on** a provisional price, so the provisional hours are dropped and the
spread, the cheapest hour and the dearest hour are computed over the published
ones only; fewer than two firm hours is still a refusal, which is where the
§11.4 fallback (wholly provisional) lands. The permitting variant now refuses to
be *constructed* around a provisional point at all. The cheap-window flag became
per-hour for the same reason, so a site's maintenance charge floor does not go
dark every morning.
**Real-time / imbalance products get measurably wider thresholds.** One widening
path, driven by a set of active uncertainty sources: the product's own (§9.2 row
2, derived from the declared `PriceProduct` and never from a plugin id) and
§11.4's "no weather data" row, which the spec widens by a different trigger and
which is the same mechanism. The combination rule is `max`, not a product — two
independent doubts must not compound into a threshold nothing can clear. The
caller supplies the base round-trip cost threshold, so OPT-04 still owns what
the number *is*; this owns only how much wider it gets and why, and the allowed
verdict reports the threshold it cleared.
**An irreversible action is a value, not a judgement call at each call site.**
`Irreversible` carries the hours an action commits — the maintenance drain's
window is derived from `maintenance.DRAIN_TIMEOUT_MIN` rather than typed twice —
and the gate looks at exactly those hours, blocking on a provisional one, on an
hour the series does not cover, and on no price data at all: three different
reasons, none of them an answer. ⚠️ It is the entry point for a start being
*justified by a price*; the calendar path main.py runs today is untouched,
because a gate that blocked on `no_data` would stop the monthly cycle on every
default install — §12's opening sentence.
**Zero new options.** No `config.yaml` key, no new defaults dict, no `o.get(k,
X)` in main.py: the module reads no options at all, so CFG-03 did not widen.
**The grid-following loop is now capped against the month's billed capacity peak
(SAFETY-07).** New `app/peakguard.py`. TARIFF-01 measured the quarter; this is the
consumer it was built for. Every cycle the guard projects the open quarter,
compares it to a ceiling and files ONE arbiter claim: a lower bound on the
setpoint at `P_PEAK`. That shape is both behaviours §10.1 asks for — a hard clamp
on charging and pre-emptive discharge — and it cannot cap discharge or export,
because a floor cannot. `excess = 900 × (projected − ceiling) ÷ remaining`, and
the floor is the MEASURED battery power plus that: a floor built on the standing
command winds itself to the rail whenever the inverter fails to follow, and one
built on delivered power cannot.
**It trips where SAFETY-18 only notifies, and the captures decided that.** On the
healthy reference day it engages on zero of 95 quarters; the action is
level-triggered, unlatched and re-derived every cycle, so a false engagement costs
one cycle of discharge rather than a parked battery. Replayed on 2026-08-20 the
billed quarter goes from **5029.8 W — above the inverter's own 5000 W rating — to
3485 W**, under the soft limit and without saturating. Quarters under the limit
across both committed days: 189/190 → 190/190. Two days is not thirty; AC 3 is
still TARIFF-01's open item and this does not claim it.
**Blindness forbids importing, and it is checked before the projection is
graded.** A fresh averager projects a confident 0 W, which is under every ceiling
there is; a meter gap longer than `meter_max_age_s` makes the projection read LOW;
and a frozen meter reading export projects 0 W at full coverage. All three become
a floor of 0 W, which is one-directional and cannot cost pack energy. That is the
backstop SAFETY-18 could not be — its alarm arrives at 300 s of a 900 s quarter
and commands nothing. The frozen term is `freeze.looks_frozen()` itself, evaluated
on this cycle's standing command, not a second copy of the conjunction.
**The ceiling is `peak_cap_w`, raised only by an OBSERVED reading.** `NO_RECORD`
and `NOT_OBSERVED` both leave it at the cap, so an unreadable peak store makes the
guard STRICTER. The gate is the reading's STATE, not whether a number happens to
be attached to it: today a `peak_w is not None` test behaves identically, and
depending on that coincidence is how a future last-known-peak field would silently
raise the ceiling off a read that failed. `headroom_w()` is deliberately not
consumed — `cap − peak` turns a zero peak into FULL freedom.
**Two defects found building it, both in the interaction rather than the
arithmetic.** A LIMIT does not out-vote another LIMIT — `arbiter.resolve()` applies
every limit at or above the winner's priority and takes the most restrictive — so
the peak floor (`lo ≥ 0`) and the maintenance charge-only shaping (`hi ≤ 0`)
resolved to a CONTRADICTION and 0 W, parking the battery in the exact quarter it
should shave. Fixed by suppression rather than priority: main.py drops the
maintenance shaping while the guard is engaged, which is what that branch already
did for the optional `peak_forecast_entity` — a key that is empty on a default
install, so until now the suspension could not fire on the site that needed it.
And thresholding `excess > 0` released the claim the instant it started working,
producing seventeen engage/release cycles in one 900 s quarter (§10.2's
oscillation) and leaving that quarter 49 W over; the threshold is now the floor
itself, which is the same arithmetic read as a level rather than as a switch.
**`PeakTracker.project()` no longer reads a private name with a default.**
`getattr(averager, "_last_net", 0.0)` failed quiet AND in the disarming direction:
a rename credits 0 W held, the projection reads low, and the money guard does not
engage. `QuarterAverager.held_net_w` is now a documented public property, read
without a default, and `Projection` carries it. TEST-13 item 4.
**No new option, and no fourth defaults site.** The ceiling is `peak_cap_w`, the
coverage threshold is `meter_max_age_s`, the freeze predicate is `meter_freeze_s`,
and the achievable discharge comes from `max_w` and the device rating.
`config.yaml` and `validate.py` are untouched; §14's `capacity_peak_limit_kw`
stays declined as the kW/W mismatch trap it is. On `meter_source: off` there are
no telegrams, so the guard does not run at all and the status page says NOT
COVERED — running it there would have blinded it permanently and stopped every
legacy install from charging, which is what the first cut did until
`test_clamp.py`'s export case caught it.
**Static day/night and fully-fixed tariffs, first-class (TARIFF-03).**
§9.2 puts a large share of the Belgian installed base on a static profile, and
an EMS that only works under dynamic pricing is an EMS for a minority. A new
`static_profile` option describes a two-period day/night tariff — or a single
fixed price — as JSON, and `app/static_tariff.py` turns it into the same
canonical `{start, eur_per_kwh, provisional}` series the fetched providers emit,
so nothing downstream learns that a tariff can be static.
**It is not a sixth provider plugin, and the reason is mechanical.**
`PriceProvider.capabilities()` is a classmethod, so a plugin's `PriceProduct` is
fixed when the class is written — but §9.2 makes STATIC and FIXED two different
products with two different required behaviours, and which one a site is on is a
property of the operator's data, not of any class. `StaticProfile.product`
derives it from the number of distinct prices instead. The second reason: the
plugin framework exists to stop a *fetched* figure being marked up twice, and a
number the operator typed as all-in has no publisher to disagree with.
**So the profile sits where §11.4 already says it does — under the providers, as
the fallback.** The configured-product path and the feed-is-down path are the
same generator differing in one flag: `provisional`. A static-tariff site runs
that path every day, so the degradation path for a dynamic site cannot rot
unused.
**"No arbitrage" is a type, not a boolean somebody has to remember to check.**
`TariffPlan.arbitrage()` returns a variant: the *allowed* arm carries the
spread and the cheapest and dearest hours, and the *refused* arm carries a
reason and nothing else — `.spread_eur_kwh` on a refusal raises rather than
answering 0.0. An optimiser cannot compute a trade from a refusal because it
cannot get the inputs out of one. Four refusals, all derived: the peak guard is
holding, there is no price data, the plan is provisional, or **the series is
flat**. That last one is AC2 — a fully-fixed tariff disables arbitrage by
arithmetic rather than by matching on an enum, and a dynamic feed that happens
to print one price all day is refused for the same true reason.
**Peak shaving outranks arbitrage, expressed so OPT-04 cannot skip it.**
`arbitrage()` takes `peak_guard_active` as a required keyword argument, so the
spread is not obtainable without first answering whether §10.1's priority 2 is
holding. §9.1's capacity tariff is a network cost charged whatever the energy
product is.
**Time-window shifting reaches the one shiftable load that exists.** main.py's
cheap-window flag — previously fed only by the `price_now_entity` /
`price_avg_entity` pair — now falls back to the static profile, and the Web UI
gained a **Tariff** row naming the window, the price, when it next changes and
why it is or is not cheap. The rule is *strictly* below the seven-day mean:
under a flat tariff `<=` would call every hour cheap and a fixed-tariff site
would top up from the grid at any hour, which is the opposite of
self-consumption only. Seven days rather than 48 hours because a 48 h mean taken
on a Friday is two-thirds weekend, and the same Tuesday 09:00 would come out
cheap or dear depending on when you asked.
**A profile must tile every day type exactly once, checked at startup.** A gap
is refused with the uncovered range named rather than filled in — an invented
price is one an optimiser would trade on — and an overlap is refused because
otherwise one of two prices wins silently on list order. The trap this catches
in practice: `22:00–07:00 mon-fri` does **not** cover Saturday morning, because
a window applies on the day the clock reads.
**validate.py rule 7's stated reason expired, exactly as TARIFF-02 predicted.**
That ticket left a tripwire in `test_price.py` section 12 asserting that nothing
in `app/` consumed `load_prices()`, with instructions to fix the refusal's
wording in the same commit when it went red. It went red naming
`static_tariff.py`. The message now says what is true instead — the series *is*
consumed, but main.py acts on the static side of it and not on a fetched one —
and the tripwire is re-aimed rather than removed: the consumer set is pinned, so
a second consumer (OPT-04) goes red again, and the expired phrase is asserted
gone so a bad merge cannot restore it. Rule 7 also grew a second refusal:
`static_profile` alongside the Home Assistant price pair is the same
silent-loser conflict, and a live one.
**No new place for an option default (CFG-03 is not widened).**
`static_profile` was added to `app/price.py`'s `PRICE_OPTION_DEFAULTS` — the one
in-code mirror TARIFF-02 created and pinned to `config.yaml` by a check — rather
than to a defaults dict in the new module, which has none. main.py grew no
`o.get("static_profile", …)` fallback. That is TARIFF-02's pattern, stated
here so a reviewer does not have to infer it.
**Measured, on the data that exists.** `test_static_tariff.py` replays the two
committed days of this house's real P1 meter (`scenarios/p1-net-2026-08-{20,23}`)
priced under a Belgian day/night profile. 2026-08-20 is a Thursday: 15.220 kWh
imported, 9.606 in the day window and 5.614 in the night one, EUR 4.7185 under
day/night against EUR 4.6725 flat, and shifting the day-window energy into the
night window saves EUR 0.8069 — which is 9.606 kWh x the 0.0840 spread, derived
twice and required to agree. 2026-08-23 is a Sunday: 0.728 kWh, **all** of it
night-priced, which is the weekend row proving itself on real data. §17 names
six Belgian scenarios and a static-profile case is not among them; this is the
seventh, and it is two captured days rather than a season — the file says so
rather than implying an annual figure.
Also worth knowing before OPT-04: on realistic Belgian day/night numbers the
whole-tariff spread is about 0.08 EUR/kWh, **below** the shipped
`cycle_cost_threshold_eur` of 0.10. A correct optimiser will decline to cycle
for the tariff alone on such a site. That is a product finding, not a defect.
**Price provider plugins, and one canonical all-in price format (TARIFF-02).**
`app/price.py` ships five providers - `generic_dayahead` (wholesale EPEX BE),
`engie_dynamic`, `totalenergies_dynamic`, `eneco_eddy` and the offline
`manual_csv` - all emitting exactly `{"prices": [{"start", "eur_per_kwh",
"provisional"}]}`, tz-aware at the Brussels offset, EUR/kWh, all-in. **Nothing
consumes it yet**: this is the seam, landed first, so that the arbitrage work
that follows never learns a supplier's name.
**Double-counting the markup is refused rather than discouraged, given a
correct declaration.** A plugin does not return a price; it returns the figure
its source published and declares which of {energy, markup, taxes} that figure
contains. The framework adds the complement, once. Engie and TotalEnergies
publish a retail figure with their margin already inside; adding the configured
3 c/kWh on top would make every future arbitrage decision wrong by that amount
with nothing reporting it.
Two mechanisms, because one was not enough. `PluginOptions` raises on the
framework-owned keys - and review of PR #16 then wrote a double-counting plugin
three more ways, one of them touching nothing but `PRICE_OPTION_DEFAULTS`, a
public dict in the module every plugin already imports. So `register()` now also
**refuses at import any plugin whose own code mentions a framework key**
(`code_leaks()`, docstrings stripped via `ast` so a plugin's mandated
`SOURCES:` line does not false-positive). Honest wholesale baseline 0.188
EUR/kWh; every attack landed 0.219.
**The guarantee's precise shape**, stated because an overclaim is worse than no
claim: the framework adds the complement exactly once *given a correct `sources`
declaration*. A plugin that declares `{energy}` while its feed is really all-in
still comes out one markup high while touching no framework name, and no code
can catch that - the declaration is the plugin's unverifiable claim about
somebody else's tariff. What is mechanised is reachability; what stays human is
truthfulness.
**The product type is declared, not inferred from the plugin's name.**
[⚠️ **FALSE, corrected by TARIFF-07: `eneco_eddy` was never a real-time /
imbalance product — Eneco's dynamic product is day-ahead-indexed — and the
plugin has been withdrawn. The declaration mechanism described here is
unchanged and is now exercised only from outside `price.py`.**]
`eneco_eddy` is a real-time/imbalance product and gets widened arbitrage
thresholds; that reaches a consumer through `capabilities().product` and
`volatility_regime()`, never through a name comparison. `test_price.py` asserts
mechanically that no plugin id appears anywhere in the framework's own code,
and drives a sixth provider defined inside the test file to the correct regime
with `price.py` untouched.
**"No price data" is a type, not an empty list.** Following the same rework
`sim/riglock.py` took, a fetch returns `PriceRead.series(...)` or
`PriceRead.no_data(reason)`, and only the first carries fields. An empty series
is not constructible; `no_data` has no `.points` to iterate, no `.at()`, and
`.get("points", [])` raises rather than returning the default. **A day of free
electricity and a day with no prices are different instructions** - arbitrage is
pointless under the first and forbidden under the second - and an implementation
that returns `[]` on a failed fetch cannot tell them apart. Every site-level
failure returns `no_data`; nothing raises into the control tick.
**What is not verified, and cannot be by an offline suite:** every fixture is
synthetic, so the five feed URLs and JSON shapes are checked against a belief
about what those suppliers publish, not against the feeds. The parse layer is
exercised; the contract with each supplier is not. Expect the first live fetch
of each to need a shape fix, and note that a wrong shape degrades to
no-price-data rather than to a wrong price.
**`manual_csv` is the documented offline fallback** and needs no network, no
supplier account and no HTTP stack. See DOCS.md for the format. Its `start`
column must carry a UTC offset - a bare local timestamp is refused, because one
hour every October names two moments.
**Injection is priced separately** (`export_price_eur_kwh`), a scalar rather
than a second series, and negative values are accepted. Consumption plugins
cannot reach it.
**`price_provider` may not be combined with `price_now_entity` /
`price_avg_entity`** - the add-on refuses to start on that pair. The Home
Assistant sensors are the existing delegation of pricing to HA and still work
alone; with both configured they would silently keep deciding while the status
page named a supplier that decided nothing.
**No timezone database is used.** The shipped Alpine image has no `tzdata`, so
Brussels offsets are computed from the EU rule and every instant is carried as
UTC and rendered at the offset that applies to it. The checks drive both 2026
transitions - the 23-hour and 25-hour days - rather than a normal day, where a
fixed 24-slot implementation and a correct one agree.
**The capacity-tariff peak is now measured, banked and survives a restart
(TARIFF-01).** New `app/tariff.py`. The 15-minute block average itself was
already built and unwired - `p1.QuarterAverager` computes clock-aligned 900 s
blocks, time-weighted over irregular telegram spacing, offtake-only and
per-phase - and `P1Ingest.blocks` was a 96-entry list a restart erased. This
adds the SQLite behind it (`/data/tariff.db`): one row per completed quarter in
the indefinite 15-min tier, one row per calendar month in the permanent peak
tier, and no `DELETE` against either anywhere in the module.
**Blocks, not a sliding window.** The card says "rolling"; 9.1 bills "the
highest 15-minute average offtake", stated per QUARTER. "Rolling" here means
continuously updated, not a trailing-15-minutes window - a trailing window
reports a peak the meter never bills, and reports it HIGH, because a burst
straddling :15 fills it completely while contributing to two block averages at
partial weight.
**A restart mid-block resumes it, and a restart that outlives the block banks
it.** `QuarterAverager` grew `snapshot()`/`restore()`; the tracker checkpoints
the open block every 15 s (worst case 1.7 % of one quarter) and clears the
checkpoint in the same breath as a block close. The held sample keeps its
ORIGINAL timestamp across the restart, so the outage is integrated under the
same `max_hold_s` rule a running process would apply and uncovered seconds drag
the closed block DOWN rather than being held forward. `quarter_start` is the
primary key and a re-bank may only ever RAISE a figure, so a replay cannot
double-count and a partial re-run cannot lower a quarter already measured.
**An unreadable store is not a zero peak.** `peak()` answers `OBSERVED` /
`NO_RECORD` / `NOT_OBSERVED` and carries `peak_w = None` unless observed - the
`riglock.holder()` fix applied to something that spends money. A peak read as
0 W hands SAFETY-07 maximum headroom and silently disarms the guard at the
moment its own storage breaks, so there is no accessor that defaults it: a
caller who forgets gets a `TypeError`, and the status page prints a different
row for "no quarter yet" than for "the database did not answer".
**Calendar months are LOCAL, blocks are UTC.** A quarter starting 22:15 UTC on
31 August bills in September. Block alignment still needs no timezone.
**No new option, and no second peak entity.** The soft limit is the existing
`peak_cap_w`; `config.yaml` and `validate.py` are untouched, so CFG-03 is not
widened. `peak_forecast_entity` stays the input to `maintenance_charge_floor()`
- repointing that consumer changes what moves energy and belongs to SAFETY-07.
**It measures and nothing else.** No claim, no clamp, no command; graded on the
parsed syntax in `test_tariff.py`, which also proves the same grader lights up
on `main.py`. Per SAFETY-20, the quantity is DELIVERED power - `tariff.py` only
ever sees `P1Sample`, the meter's own reading, never a setpoint.
**AC 3 is not met and the check says so.** It asks for 30 days of replay; two
days of this house's real meter exist (2026-08-20, 2026-08-23), now committed as
`scenarios/p1-net-*.jsonl.gz`. `test_tariff.py` part 9 replays them, reports
the percentage under the shipped limit next to the sample size in days, and
asserts nothing about the 95 % figure.
**A computed setpoint over the rating now alarms instead of being clipped in
silence (SAFETY-03).** The clamp was never the missing half - specs.md 10.3
records an unclamped integrator climbing ~130 W per 4 s past 10 kW and reporting
**14 768 W** while pinned at the 5 kW rail, and a silent clamp turns exactly that
into a flat, legal-looking 5000 W hold. `write_setpoint()` - the one path every
write takes, cycle, heartbeat, operator button and shutdown alike - now clamps to
the **validated** `max_w` and reports whether the raw value differed, and
`Controller.check_output_clamp()` raises `OUTPUT_CLAMP`: a persistent
notification (`goodwe_output_clamp`), an `ERROR`, an event row and a red status
banner. **Not a trip**: the clamped value is written and the loop keeps running,
per 11.2's "clamp *and alarm*".
**The bound is `max_w` and nothing is `min()`ed at runtime.** Section 14 requires
the loop clamp and the driver's `setpoint_limit_w` to agree, validated at startup
with a refusal on mismatch - which CFG-01 already ships. The device range is
still applied second, as defence in depth; after a successful validation it
cannot engage, so if it ever does, that is louder than the first stage and it
alarms too, naming the bound. No new config key: the guard's limit is the one
the operator already set, and its cadence is a module constant.
**`Decision` grew `i_clamped` / `clamped` booleans, and that is the load-bearing
part.** `reason` is one string that later stages overwrite - a cycle that clamps
the integrator and is then slew limited reports `slew-limited`, and one that
clamps while saturated reports `saturated-freeze`. Both *are* the winding case,
so an alarm keyed on the string is silent on exactly the cycles it exists for:
mutating main.py back onto `"clamp" in decision.reason` drops the 10.3 replay
from 2 engagements to **0**. The flags are set where the clamp happens and are
never overwritten. On a default install (`integrator_max_w` following `max_w`)
the integrator bound is the one that bites and the output clamp is unreachable,
so the integrator flag is the whole signal.
**Distinct from the saturation freeze, and checked in the negative.** A clamp is
a *software* bug signal; saturation is the *hardware* failing to follow a legal
command, and its action is to freeze the integrator, not to alarm. They share no
reason code, notification id, status row or counter. `test_clamp.py` drives a
loop that saturates for 10 consecutive cycles at 1.4 % of the rating and asserts
zero clamp notifications, zero engagements, no log row and no status row - after
first asserting that the saturation freeze *really did* engage, so the silence is
an observation rather than a scenario that did nothing.
**The action log is coalesced per episode, and that was a real bug.**
`log_event()` keeps 40 rows; one row per engagement flushed the entire ring
within 40 cycles of a winding loop, and the first thing it evicted was
SAFETY-18's own `METER FROZEN?` row - this guard silencing another guard's log.
Caught by `test_freeze.py` going red, not by inspection. One row per episode now,
carrying the exact engagement count read off the counter.
**A non-finite setpoint is refused, and it was worse than passing one through.**
`nan` is loss of input (11.1 rule 1: command zero, keep commanding), not an
out-of-range value. Measured: because every comparison against `nan` is False, a
naive `max(-limit, min(limit, nan))` keeps its *first* argument and turns a `nan`
into a command **at the full rating**, then reports it as a clamp engagement.
**Review fixes (PR #12).** Three, and the first was a behavioural regression
this PR introduced: `clamp_to_rating()` **returned early** from the `max_w`
stage, so the device bound - the "applied second, defence in depth" half - was
reached only when the rating bound had NOT fired. The bigger the overshoot, the
less the guard did. At `max_w` 5000 against a +-4000 device, +9999 emitted
**+5000 W, outside the device range**, while a mere +4500 was correctly held to
+4000. That undid the pre-PR guarantee "never send a value the device will
reject outright" and undercut this module's own case for clamping to `max_w`
rather than a runtime `min()`, which rests entirely on that stage catching a
validation that did not run. Both stages now always run, the result names both
bounds when both bite (`max_w+device`), and the property is asserted over a
492-point sweep rather than on witness values - the defect was invisible to any
single-value check that happened to sit inside one stage. No reachable
production path was found for it (two validation gates and the arbiter bound sit
in front), but latent is not harmless.
Two harness defects, both of the kind where a check cannot fail for the value it
forbids: the hysteresis check issued `range(CLEAR_CYCLES - 1)` clean cycles,
which at `CLEAR_CYCLES = 1` issues **zero** and passes while printing
"0 clean cycles do NOT clear it" - green for the chatter setting the constant
exists to prevent. And the re-assert check stimulated at `REASSERT_S + 9`, green
for **any** value including 3600, i.e. the hour of silence the module promises
not to produce. Both are now written in wall-clock terms that do not move when
the constant does: **one** clean cycle must not clear the alarm, and a loop
pinned across the 900 s capacity-tariff quarter must speak at least 5 times and
on no more than 20 % of cycles. `CLEAR_CYCLES = 1`, `REASSERT_S = 3600` and
`REASSERT_S = 0` each go red.
**`test_clamp.py`** (new, assert-based, no framework) covers the clamp
arithmetic and its boundaries - exactly +-`max_w` is *not* an engagement - the
alarm's edge/re-assert/hysteresis cadence, the 10.3 runaway replayed through the
real `Controller.cycle()` against an unclamped transcription, the saturation
negative, and the direct-write path. Six author mutations reproduced red,
including "clamp kept, alarm deleted" (the historical build) and "alarm keyed on
`reason`". Two of the check's own hypotheses about how the freeze and the clamp
interact were **refused by the sweep** and rewritten to what it measured: a
frozen cycle *can* clamp, and does so exactly when the integrator reverses.
`test_freeze.py`'s notification assertions now filter by `notification_id`
rather than by service - the add-on raises more than one kind of notification,
and its railing scenarios legitimately raise this one too.
**Cheap-window maintenance charging was unreachable at the shipped defaults, and
now the config that makes it unreachable is refused (MAINT-04).** `config.yaml`
shipped `max_w: 2000` against `maintenance_charge_w: 2500`. The cheap-window
shaping files `Claim.limit(hi = -maintenance_charge_w)` against the supervised
SAFETY limit's `lo = -max_w`, so `lo > hi` — the arbiter's clause 3, correctly
resolved to **0 W** and logged as a CONTRADICTION. **Maintenance silently never
charged in a cheap window on a default install**, and the only evidence read
like a bug in the arbiter rather than like the two numbers an operator set.
Measured against the real arbiter, loop asking +500 W:
```
max_w=2000 hi=-2500 -> +0 W contradiction=True
max_w=2500 hi=-2500 -> -2500 W limited by supervised(max_w)
max_w=3000 hi=-2500 -> -2500 W limited by maintenance(cheap-window charge)
```
`validate_startup_config()` now refuses `maintenance_charge_w > max_w` (rule 6),
the same shape as CFG-01's `sign_disagree_w >= max_w`: a number the operator set,
overridden by a layer they cannot see. Equality is reachable (`-max_w` is a
single valid point) and deliberately not refused. Verified by starting the
add-on on the pre-fix pair: exit 78, the refusal banner, no traceback.
**`maintenance_discharge_w` was checked, not assumed, and it is NOT the same
case.** The shaping is not symmetric. The drain phase does not shape the loop,
it OWNS the actuator — `Claim.set(P_MAINTENANCE, +discharge_w)` — and a SET is
*clamped* by the limits above it rather than contradicted by them. 2500 against
a 2000 W ceiling emits **+2000 W**, and the arbiter's own `explain()` prints
`maintenance -> 2000 W, limited by supervised(max_w)` every cycle. Nothing is
silent and energy still moves; the cycle completes slower (13.8 kWh usable at
2000 W is ~6.9 h against the 720 min drain timeout). **Warned about, not
refused.**
**The shipped defaults changed so the validator does not reject them.**
`maintenance_charge_w` and `maintenance_discharge_w` are now **2000**, at the
shipped `max_w`. `max_w` was deliberately NOT raised instead: it is the
supervised safety ceiling and raising a default upward ships more power to every
new install. Raising `max_w` (the reference install runs 5000) is what unlocks a
faster maintenance cycle — raise it first, then these. `test_validate.py` now
reads `config.yaml` itself and asserts the shipped numbers pass the rule, so a
default that the validator refuses cannot ship again.
### ⚠️ Upgrading an existing default install: the add-on may refuse to start
An install still carrying `maintenance_charge_w: 2500` against `max_w: 2000`
now meets rule 6 and **exits 78 with the refusal banner** instead of starting.
That is the intended behaviour — the configuration was already broken, it was
just silent about it — but an add-on that will not come back after an update
needs the fix stated here rather than only in the log.
**The fix, either way: set `maintenance_charge_w` to `2000` or lower, OR raise
`max_w` to `2500` or higher** (Settings → Add-ons → GoodWe RS485 Controller →
Configuration), then start it. The banner in the log says the same thing and
names both numbers.
Whether you hit this at all depends on whether the Supervisor kept the old
value, and **both cases are covered above because we did not verify which one
applies here.** The Supervisor merges an add-on's *stored* options over the
defaults in `config.yaml`, so:
- **A key the operator never edited** re-derives from the new `config.yaml` and
becomes 2000 on upgrade. Non-event, nothing to do.
- **A key the operator did set** persists at 2500 and the add-on refuses to
start until it is changed. Note this includes anyone who used the
Configuration page's YAML editor, which writes the whole options block back —
so "I never touched that field" is not a guarantee the old value is gone.
⚠️ **This is reasoned from the Supervisor's documented merge behaviour, not
measured on the live install.** The reference install's stored options could not
be read (`/api/hassio/` refuses a long-lived token) and probing it was out of
scope — it regulates a real battery. It runs `max_w: 5000` and is unaffected
either way.
⚠️ **Known, deliberately left, and worth a follow-up:** `main.py` and
`maintenance.py` still fall back to **2500** when the key is absent from the
options dict, while `config.yaml` and `validate.py` now say 2000. Unreachable on
a Supervisor install (every key is always supplied) and reachable only from
tests/`sim`. The real fix is one source of truth for option defaults, which is
bigger than this ticket and touches files another ticket is in.
## 0.5.2
**A meter frozen at a wrong-but-fresh value now raises an alarm. It still is not
stopped.** (SAFETY-18)
A meter that answers `200 OK` with a stale document forever is *arriving* on
every poll, so every freshness mechanism in the stack reads it as healthy:
`meter_max_age_s` is reset by each response, the firmware watchdog is fed by the
heartbeat and by a sample age that never climbs, and the arbiter contributes only
±`max_w`. The loop integrates a constant error and rails — replaying the real
`compute()` at 15 s cycles, in 150/60/30 s at `max_w: 2000` for a meter frozen at
350/1000/≥3000 W, and 360/135/75 s at `max_w: 5000`. **The live install runs
`max_w: 5000`**, which is both the schema maximum and the device rating.
The new detector (`app/freeze.py`) is a **conjunction**, not the bare
`unchanged_s` threshold TEL-05 measured and rejected:
unchanged_s ≥ meter_freeze_s AND |command| within 5 % of max_w
Both terms already existed and were already on the status page. They fail for
independent reasons: at the converged point the command is nowhere near the rail,
and at the rail against a real load the kWh registers move within seconds. At the
shipped 300 s there is also a structural relation, not just a margin — the
slowest a healthy 1 Wh register can tick and still look unchanged is 12 W, which
is inside the 15 W deadband, so the command there is parked at 0 W and the two
halves cannot both be true.
**Notification only, deliberately.** An HA persistent notification (fixed
`notification_id`, so a repeat replaces rather than stacks), an `ERROR` log line,
a UI event and a red status banner. No claim, no latch, no 0 W: a false trip
parks the battery and the operator's next move is to switch the guard off; a
false notification costs an alert. The trip is a separate decision that needs
data from a real install.
- New option `meter_freeze_s` (default 300, range 60–3600, no "off").
- **Only `meter_source: homewizard_local` is covered** — it is the only transport
that sees the meter's own document. Everywhere else the status page says
**NOT COVERED** rather than "armed".
- `DOCS.md` now states the **capacity-tariff exposure** this does *not* close:
`peak_cap_w` caps maintenance charging and nothing caps the loop, so a lying
meter can drive a 5 kW unattended import, and ≥15 minutes of that sets the
month's billed peak (measured: one 4998 W quarter moved a monthly peak from
4832 → 5013 W). That cap is SAFETY-07.
- `test_freeze.py` grades it in both directions: silent over 40 minutes of the
live house's real converged capture (committed as
`scenarios/p1-age-2026-08-26.jsonl.gz`), silent over an hour of TEL-05's
low-power case where a bare threshold is shown to fire, and alarming on a
genuinely frozen meter driven over real HTTP through the real
`HomeWizardLocalSource` — against the rig's own `hwsim` `freeze` fault when the
infra repo is reachable, an equivalent stub otherwise. Its negative twin is the
load-bearing one: the same railed command against a meter that is still moving
must stay silent at the same threshold.
## 0.5.1
**SAFETY-02's latch now survives an add-on restart, which is the difference
between a latch and a pause.** `auto` was persisted and `sign_wd.tripped` was
not, so reconstructing the `Controller` against the same store — exactly what a
container restart does — brought it back **armed, into the same fault, with no
operator involved**: `tripped=False`, banner back to `NOT READY`, and it resumed
commanding (measured: −1000 W, −2000 W) before re-tripping 180 s later. Under a
Supervisor that restarts a crashed add-on that is a loop of three-minute
wrong-direction bursts — and "restart the add-on" is the first thing an operator
looking at a `FAILSAFE` banner and a 0 W inverter will try.
`sign_tripped` and `sign_reason` are now `Store` keys beside the maintenance
state, written the moment the trip happens (reason first, flag second, so a crash
between the two can never persist a latch with no explanation) and restored in
`Controller.__init__`. Cleared only by the operator's start. `DOCS.md` said "it
does not clear itself"; that was false across a restart and now is not.
Also in this release, all of it review follow-up rather than new behaviour:
- **The arming gate is tested against the real arbiter.** It was the decision the
whole ticket turns on and it was asserted in three comment blocks and verified
by nothing — every case passed `following` in as a literal. `test_watchdog.py`
now derives it from `resolve()` across twelve claim configurations, including
the redirect case `winner == "loop"` alone would have got wrong and the `lo`
limit that raises magnitude without flipping sign.
- **The MQTT `status: "failsafe"` value is tested.** The check that claimed to
cover it restated the assertion three lines above it and never touched the
payload.
- **A forward hazard written down where it will be read, and made to bite.**
`winner == "loop"` disarms the watchdog under any higher-priority SET claim.
Today only maintenance and the safety stops emit one and neither follows the
meter; a peak-shaving strategy at `P_PEAK` **does**, and would blind the
watchdog for every peak event.
The gate is now `watchdog.loop_is_following()`, called by both `main.py` and
the test, for the same reason `disagrees()` was extracted: the test held a
*transcription* of the shipped expression, so editing the shipped gate alone to
`winner in ("loop", "peak")` left every suite green while the watchdog went
blind. Two copies, and the one that drifts is the one doing the grading.
⚠️ Extracting it was not sufficient on its own. The realistic P_PEAK row —
peak shaving asking for *more* than the loop — still could not detect the
widened gate, because the magnitude term rejects it regardless and masks the
winner term. A second row with peak asking for *less* isolates `winner` as the
only deciding term, and that is the one that turns red.
- **The worked example described a configuration that does not ship.** At the
defaults `maintenance_charge_w` (2500) exceeds `max_w` (2000), so that claim is
an arbiter *contradiction* resolving to 0 W, not a −2500 W charge. The example
is now written at 1500 W. (The contradiction is a real pre-existing bug —
a default cheap-window maintenance charge silently never happens — filed
separately, deliberately not fixed here.)
- **`disagrees()` is public**, so `sim/replay_sign.py` stops carrying its own copy
of the predicate it grades.
- `held_s` takes the clock instead of reading one, restoring the pure-function
property the module advertises.
- **The `sign_reason`-before-`sign_tripped` write ordering is enforced, not just
documented.** Swapping the two lines used to pass every check. A store that
fails the second write now proves the property the ordering exists for: what
survives a crash mid-trip is a reason with no latch, never a latch with no
explanation.
- Measured figures corrected throughout: 93.4 % / 4212 of 17280 (was 92.9 % /
4127 of 16349), per-cluster 0.3 / 0.9 / 10.5 / 0.0 %.
## 0.5.0
**SAFETY-02 — the sign-disagreement watchdog.** The add-on now watches whether
the setpoint it is emitting and the grid figure it is regulating on point the
same way. If they oppose each other, both over `sign_disagree_w` (300 W), for
`sign_disagree_s` (180 s) **continuously**, it files a failsafe claim at
`P_SAFETY`, commands **0 W**, and latches there until an operator starts control
again. New module `app/watchdog.py`; new options `sign_disagree_w` and
`sign_disagree_s`.
This is the gap the existing failsafes leave open. The stale-input watchdog asks
whether the meter is still talking, the saturation freeze asks whether the
inverter can follow, the output clamp asks whether the number is too big — a
loop can pass all three while charging the battery out of the grid, because the
only thing wrong is the sign. On 2026-08-20 a commercial controller did exactly
that four times in one day, for up to 77 minutes at a stretch, and reached a
commanded −14 768 W against a ±5000 W inverter.
Validated against that day. `sim/replay_sign.py` in the infra repo drives this
module over the committed RS485 captures of both 2026-08-20 (the four episodes)
and 2026-08-23 (healthy): **18 trips on the fault day, every one inside a window
`NOTES.md` §4.7 accounts for, and 0 on the healthy day.** The four episodes do
share one signature rather than merely resembling each other — sign agreement
runs 0.3 / 0.9 / 10.5 / 0.0 % inside them against 93.4 % on the healthy day.
Three decisions worth knowing about:
- **It is disarmed whenever the grid-following loop is not what is driving.**
Sign agreement is a property of a loop that follows the meter. A maintenance
grid charge opposes the meter *by design* — 2500 W of charge into a house
drawing 500 W is +3000 W on the meter against a −2500 W command, for hours —
and armed unconditionally this would trip on every maintenance cycle. The gate
tests the emitted number, not the winning claim's name: a limit claim can let
the loop "win" and still replace its value with one pointing the other way.
- **The trip latches.** Commanding 0 W removes the command side of the
comparison, so the disagreement always clears the moment the trip works.
Un-latched, this would trip, clear, and hand the actuator back to the loop that
was driving the wrong way, every three minutes forever.
- **`sign_disagree_w` at or above `max_w` is refused at startup** (validator rule
5). The arbiter never lets a command exceed `max_w`, so such a threshold makes
the watchdog incapable of firing while the status page still reports it armed.
A disarmed guard that advertises itself as armed is the failure mode this
project keeps refusing to ship.
What it does **not** catch, stated so nobody assumes otherwise: an inverter that
acts opposite to what it was told moves the meter *further* the same way, so
command and meter agree while everything runs away. That is the saturation
freeze's job, which compares the command against the battery's actual power.
`test_validate.py`'s "the smallest sane max_w still starts" case now names a
reachable sign threshold, because a 1 W ceiling genuinely does disarm the 300 W
default and is now correctly refused.
## 0.4.0
**CFG-01.** The add-on now refuses to start on a configuration it cannot honour,
instead of logging a line and carrying on. `validate_startup_config()` runs in
`amain()` before the broker, the web server or any task exists, so a refusal
cannot leave half a controller running behind a UI.
It refuses only where continuing produces one of two outcomes: **(a)** a stated
limit is untrue - the operator configured a bound and a lower layer silently
enforces a different one - or **(b)** the add-on is inert and indistinguishable
from healthy. (b) is not a special case of (a): with no `setpoint_entity`, layer
1 pinning the inverter at 0 W is the failsafe *working*. The system does not
become unsafe, it becomes a convincing impression of a working controller.
Four things qualify:
- **`max_w` above (or below) the setpoint device's own rating.** This is the one
that changed behaviour. It used to warn `the device wins` and run anyway, with
`write_setpoint()` silently clamping, so the configured ceiling was never the
real one and the only evidence had scrolled off the log. The refusal names the
configured value, the device's value, and which wins.
- **No `setpoint_entity`.** A controller with no actuator: every write is a
no-op, the device rating is never read, and the ESP32 heartbeat that holds off
the layer-1 failsafe never happens. It ran, looked healthy, and moved nothing.
- **A `meter_source` that can never produce a reading** - missing `p1_host`,
missing `p1_net_entity`, a blank MQTT topic, a phase list disagreeing with
`meter_phases`, an unknown source name, or a `meter_poll_s` at or past
`meter_max_age_s`. These were already caught, but they only *disabled
ingestion*, which leaves the grid reading None forever: permanent "inputs
missing", 0 W, and a status page indistinguishable from a healthy meter nobody
has sent anything to yet.
- **`meter_max_age_s` above the firmware's ingest veto.** The schema accepts
`int(5,300)`; the ESP32's threshold is a compile-time `max_age_s: "30"` and it
trips layer 1 at `p1_age_s >= 30`. Set 120 and the add-on treats a 119 s
reading as fresh and keeps commanding, while the firmware has already vetoed
and is holding the inverter at 0 W - healthy meter, running controller,
nothing moving, and no line anywhere saying the number you set was overruled.
Structurally the same fault as the `max_w` case. Only *above* the veto is
refused: below it the add-on gives up first, which is fail-safe and visible on
its own status page. Mirrored as `validate.FIRMWARE_INGEST_VETO_S` - it cannot
be imported from a compile-time YAML substitution, so it carries a note about
the one direction in which it can go stale.
`max_w` at or below zero is refused too. Schema-blocked on a real install, but
`validate_startup_config()` is now also the simulation suite's entry point, and
a non-positive `max_w` inverts the arbiter's `supervised` bounds into a
contradiction that resolves to 0 W - i.e. it would read as a safety trip rather
than as the typo it is.
The predicates for the meter group still live in `p1.validate_meter_options()`,
which `build_source()` also calls - one definition, two callers, not two
competing validators. Two transports gained a check they never had: `ha_dsmr`
with only one of its two entities, and `mqtt_p1` with a blank topic, both of
which previously built a transport that could never read.
Deliberately **not** refused, because it is untidy rather than unsafe:
`integrator_max_w` above `max_w` (the arbiter still bounds the wire to ±max_w,
so the cost is unwind latency, not amperage - warned), a missing `soc_entity` /
`batt_entity` (fail-safe, and already a red NOT READY banner naming it), a
`setpoint_entity` that has not appeared on the Core API yet (ESPHome is routinely
late; refusing would make a slow boot need a human - re-checked once the real
rating arrives), and a thin-but-nonzero `meter_poll_s` margin.
A refusal is legible as a refusal: a banner that says in words that this is a
configuration problem and nothing is broken, the numbered problems, no traceback,
and exit status 78 (`EX_CONFIG`).
**SAFETY-12.** The control loop now evaluates on a clock as well as on a change.
`run_control()` ran `cycle()` only when the meter value differed from the
previous poll, so a meter that repeated a value ran **no control cycles at
all** - while the heartbeat went on re-emitting the last command and the
firmware went on putting it on the wire every 2 s. Layer 1 stayed fed, every
indicator read healthy, and a command computed from an old reading kept being
executed through whatever the load did next. Measured on the rig during TEL-05:
70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.
**It was worse than a latency limit: it was a safety claim that could not
fire.** `stale_input_s` and the `inputs missing -> 0 W` claim both live *inside*
`cycle()`. Pre-fix, if the meter value happened to be constant, `cycle()` was
never called again - so that claim had no way to run. Constant meter, SoC entity
dying at t=4 s, same binary:
```
pre-fix writes: [(0.0, 220.0), (0.0, 220.0), (10.1, 220.0)]
final target: 220.0 W reason: 'loop -> 220 W'
post-fix writes: [(0.0, 220.0), (0.0, 220.0), (3.0, 430.0), (9.1, 0.0), (10.1, 0.0)]
final target: 0.0 W reason: 'safety -> 0 W'
```
The pre-fix controller held 220 W through the entire input outage with its
status line still reading `loop -> 220 W`, and layer 1 does not cover that case
on a `meter_source: off` install: no P1 age sensor is published, so the firmware
has nothing to veto on, while the heartbeat keeps its watchdog fed. So the old
behaviour was not "holds a stale command safely" - it was a failsafe that a
repeating meter switched off. `test_loop.py` asserts both halves.
`cycle_floor_s` (default **15 s**) is a deadline on the gap between cycles, not
a second scheduler: every cycle resets it, whichever trigger fired. On a healthy
meter it never elapses, so the cycle rate, the write sequence and therefore the
per-cycle gain the tuning was measured against are unchanged - asserted in
`test_loop.py` by driving the real loop twice on one binary (a huge
`cycle_floor_s` reproduces the old behaviour exactly) and comparing the
commanded values.
The reset is not the only thing holding that up, and the other argument is the
sturdier one: the combined cycle rate is `max(arrival rate, 1/floor)`, never the
sum. At 1/15 s the floor is strictly slower than the ~1/5 s arrival rate, so
even a hypothetical floor racing the arrivals could not exceed the nominal
healthy rate. The re-tune is unreachable by construction. ⚠️ That holds only
while `cycle_floor_s` stays above the meter's update interval, and the schema
minimum is 5 s - which is exactly the reference meter's interval. Nothing
enforces the relationship; `validate.py` is the obvious home for it and does not
have it yet.
Observed over six real minutes on the same rig, one binary, meter held at a
literally constant 350.0 W: **before, 1 cycle** (at startup) and then nothing,
the command stuck at 220 W against a 350 W import for the rest of the window.
**After, 24 cycles**, worst gap 15.14 s, and the ordinary PI ramp doing its job -
220, 430, 650, 860, 1080, 1300, 1510, 1730, 1940, 2000 W, one step per cycle,
rail at t=136 s and flat after. Three minutes with the meter parked at the
target instead: **1 cycle before, 12 after, and 19 writes either way - the same
19**. Three minutes on a normally-changing meter: **36 cycles and 49 writes on
both sides, the same values in the same order.** The heartbeat write count never
moves; the only writes the fix adds are the ten the loop was supposed to be
making all along.
15 s is bracketed, not round.
**Below it, ~11 s, and it arises more routinely than a dropped poll.**
`HomeWizardLocalSource` polls at 5.0 s against a meter that updates every 4.97 s
(NOTES.md:640). Two near-equal periods beat, so roughly once every ~14 minutes
the poller steps over an update entirely - a ~10 s gap between changed values on
a perfectly healthy meter, plus up to 1 s for the 1 s tick to notice. A failed
HTTP poll (retried on the next tick, no backoff) adds another 5 s. The floor
sits above the beat-skip so it does not fire on that alone; what it takes to
reach 15 s is a beat-skip *and* a failed poll coinciding.
**Above it, 30 s.** `meter_max_age_s` is 30 s, past which there is no reading to
evaluate, and the firmware's ingest veto is also 30 s - so the loop is
guaranteed to have re-decided at least twice inside any window in which layer 1
might otherwise be the only thing deciding. ⚠️ The default is therefore not
independently justified at 15: if the firmware's veto ever moves, this moves
with it. Noted beside the constant in `main.py`.
It is also exactly `stale_input_s`, this system's existing answer to "how long
may we hold without re-deciding".
A floor cycle runs the **full** law on the same inputs, integrator included. In
P1 mode the freshness question is already answered upstream and answered harder
- past `meter_max_age_s` the reading is None, which is "inputs missing", which
is a `P_SAFETY` 0 W claim - so a floor cycle there can only ever run on a reading
this system already calls fresh. ⚠️ That is transport-conditional: with
`meter_source: off`, `read_inputs()` takes the grid figure straight from
`hass.number()` with **no age gate at all**, so a Home Assistant entity that has
gone quiet reads as current on that path, with or without this change. Running
the full law is still right there - the alternative is a degraded second law
reasoning about an age nobody measured - but the floor does not make that path
fresh. The integrator advances per *cycle*, not per second,
so bounding the gap bounds the accumulation; `integrator_max_w` bounds it after
that. A gentler second law for floor cycles would be a second set of dynamics
nobody can test on this hardware.
⚠️ **This is not a freeze detector**, and TEL-05 established one cannot be built
here: at the converged -10 W target a 1 Wh register needs ~6 minutes to move
while the power figure legitimately repeats, so any threshold on `unchanged_s`
false-trips at the exact operating point we run at. Nothing in this change
decides whether a repeated reading is *true*. It stops "the number is the same"
from meaning "do not think". The consequence, stated plainly: against a meter
genuinely frozen at a wrong value the loop will now correct toward that wrong
value rather than hold a stale command, bounded by `max_w`, the arbiter and the
device rating. That was already what happened to a lying meter whose value
merely jittered; bit-exact repetition was never a safety property.
`DOCS.md`'s "Saturation is counted in cycles, not seconds" section documented
the old behaviour as an accepted deviation. It is **qualified, not deleted**:
the deviation survives (the window is still counted in cycles, and 3 x 15 s is
still not the specification's 10 s) but it is now bounded at 45 s instead of
open-ended, and the passage's second justification - "nothing accumulates while
it is stalled" - is called out as having covered integrator windup and not
staleness, which was the actual hazard. The same wrong argument in
`control.py`'s saturation comment is corrected too.
**TEL-04.** `meter_source: ha_signed` reads a single *signed* power entity, which
is the shape a HomeWizard P1 publishes. Both transports 0.3.0 shipped require two
unsigned registers and refuse negatives, so neither fits the meter installed here.
**TEL-05.** `meter_source: homewizard_local` polls the meter's own local API
directly. This exists because of something the HA paths cannot do: Home Assistant
fires no state change for a repeated reading and exposes no arrival signal at
all, so `sensor.p1_sample_age_s` on those transports measures time since the
*value changed*, not since the meter *reported*. Real captured data has gaps of
42 s and 97 s between changes on a perfectly healthy meter - long enough for a
30 s staleness threshold to command 0 W for no reason. Every HTTP response to the
local API is a genuine arrival, so the age means what it says.
Verified on the rig against a literally constant 350.0 W for 70 s - the exact
state where the HA path recorded zero samples in 45 s - with 14 arrivals and the
age never exceeding the poll cadence.
Set `p1_host` to the meter's address and `meter_poll_s` (default 5 s, matching
the meter's own ~5 s update). Still defaults to `off`; nothing changes for an
install that does not opt in.
Freeze detection is separate and deliberately not thresholded: a meter answering
200 OK with a stale number *is* arriving, so no arrival stamp can flag it. The
energy registers carry that as `unchanged_s`, surfaced on the status line for a
human to read rather than alarmed on - at a converged -10 W a 1 Wh register needs
about six minutes to move, so any threshold would false-trip at the target
operating point.
## Detail notes from the 0.4.x era — NOT unreleased
⚠️ Retitled with the same correction as the section above: [[TEL-05]] and the
entries under this heading shipped long ago. Two headings in one file both
claiming "Unreleased" is how a reader ends up believing running behaviour is
still pending.
**TEL-05.** A fourth `meter_source`, `homewizard_local`, which polls a
HomeWizard P1's **own local API** (`GET /api/v1/data`) instead of watching a
Home Assistant entity. Set `p1_host` to the meter's address; `meter_poll_s`
(default 5 s, the meter's own update rate) sets the cadence.
✅ **This is the first transport whose `sensor.p1_sample_age_s` measures when
the meter *reported*, and therefore the first one a firmware watchdog may
threshold.** Every HTTP response is an arrival: the meter answered, now, with
its current reading, and whether the *number* moved is not consulted. Home
Assistant cannot express that at all — a repeated reading emits no
`state_changed`, advances `last_reported` on neither serialiser, and
`state_reported` is not subscribable ("Event filter is required"). On
`ha_signed` that made a healthy meter under a flat load indistinguishable from
a dead one, and our own capture of this house's meter goes 42.2 s and 97.0 s
between changes — both past the default `meter_max_age_s` of 30, i.e. a false
trip to 0 W on a meter that is fine. If you have a HomeWizard P1, move to this
mode.
Everything TEL-01 established is reused, not re-implemented: ingest
timestamping, `meter_max_age_s`, the clock-recomputed age, the plausibility
bounds and the §20 unsigned-decode rejection, and the same `split_signed` sign
convention `ha_signed` uses. A failed or timed-out poll submits nothing, so it
is a *missing* reading — never 0 W — and it does not reset the age.
Verified on the ENV-01 rig against `sim/hwsim.py`, steady and with `--fault
freeze` injected. Still defaults to `off`.
⚠️ **An arrival stamp still cannot see a *frozen* meter**, and no arrival
detector can: a meter answering `200 OK` forever with a stale number is
arriving. The local API does expose what the HA path never had — the
`total_power_*_kwh` registers stop advancing — and the transport tracks it as
`unchanged_s`, but that is deliberately **not** folded into the age and not
thresholded: this controller regulates grid power toward ~0 W, and at a
converged −10 W the export register needs six minutes to move by its 1 Wh
resolution while the power figure legitimately repeats. Thresholding it at 30 s
would rebuild the false-trip limit cycle at the exact operating point we aim
for. Freeze detection needs the low-power case solved first, separately. It is
shown on the status page's P1 line instead — leaving it unthresholded only
holds up if a human can read it, so now they can.
**TEL-04.** A third `meter_source`, `ha_signed`, reading **one signed** Home
Assistant entity: positive = import, negative = export. That is the shape a
HomeWizard P1 publishes (`sensor.p1_meter_active_power`), and it is the meter
actually fitted here - which neither TEL-01 transport can read, because
`ha_dsmr` needs two unsigned registers and refuses a negative one, i.e. every
exporting telegram. Set `p1_net_entity`, and `p1_phase_net_entities` for the
per-phase capacity-tariff figures on a three-phase connection.
Everything TEL-01 established is inherited rather than re-implemented - the
new transport is a subclass of the `ha_dsmr` one overriding only which
entities it wants and how they become a sample. So ingest timestamping,
`meter_max_age_s`, `sensor.p1_sample_age_s` recomputed against the clock and
republished once a second, the plausibility bounds, and `unavailable` /
`unknown` treated as a *missing reading and never 0 W* all behave identically
across the three sources.
Still defaults to `off`; an existing install is unaffected until it opts in.
⚠️ **`sensor.p1_sample_age_s` is published on `ha_signed`, but must not yet be
thresholded by the ESP32 stale-input watchdog.** On the HA WebSocket paths the
age is stamped from `state_changed`, so it measures time since the value
*changed*, not since the meter *reported* - and Home Assistant exposes no
arrival signal for a repeated reading (no `state_changed`, no `last_reported`
movement on either serialiser, and `state_reported` is not subscribable over
the WebSocket). Measured on the ENV-01 rig against the real HomeWizard
integration. `ha_dsmr` mostly escapes it because a telegram moves several
entities at once; `ha_signed` has one, so a healthy meter under a flat load is
indistinguishable from a dead one. Our own capture has the house meter going
42.2 s and 97.0 s between changes. Raising `meter_max_age_s` does not fix that,
it only chooses which error you get; the fix is an arrival stamp from the meter
itself and is a separate ticket. Full detail in DOCS.md.
## 0.3.0
**SAFETY-04.** The control law's integrator is now an explicit accumulator,
bounded independently of the output clamp instead of inheriting whatever
headroom the clamp happened to leave. It also freezes while the inverter is
not tracking, rather than continuing to wind up against a command nothing is
acting on. `integrator_max_w` (default `0`) governs the bound; `0` means
"follow `max_w`", which is the existing behaviour.
Behaviour is unchanged at the defaults - a 4,928-case equivalence sweep
against the previous control law confirms it decides identically at
`integrator_max_w: 0`.
**TEL-01.** P1 meter ingestion, so a Belgian P1's two unsigned registers
(consumption, injection) no longer need a hand-written signed template
sensor: the subtraction moves into the add-on, done once and tested. Two
transports, chosen with the new `meter_source` option: `ha_dsmr` subscribes
to the DSMR integration over the HA WebSocket, `mqtt_p1` reads a topic.
Defaults to `off`, which keeps the existing `meter_entity` path untouched -
nothing changes for an install that does not opt in.
Enabling it publishes `sensor.p1_sample_age_s`: seconds since the newest
accepted telegram, recomputed against the clock and republished roughly once
a second rather than only when a telegram lands. That is deliberate - Home
Assistant only pushes a state on change, so a meter sitting at a genuinely
constant reading would otherwise look identical to a dead one. Watching the
age instead means a frozen meter shows a climbing age, not a flat line. The
firmware watchdog subscribes to this exact entity id.
Known limits, both already in DOCS.md: on `mqtt_p1`, a bridge stuck
republishing its last telegram still "arrives", so the age cannot detect
that particular failure - prefer `ha_dsmr` where both are available. And a
dead P1 meter takes 45 s to reach 0 W commanded (30 s for `meter_max_age_s`
to call the reading stale, then 15 s of `stale_input_s` on top), which is
`meter_max_age_s` and `stale_input_s` stacking, not either one alone.
## 0.2.1
`target_grid_w` (default -10 W): what the meter should rest at. The deadband
holds any resting point inside it indefinitely, and the meter bills import and
export on separate registers, so resting at +14 W import costs 0.34 kWh/day
with the loop behaving perfectly. Biasing the target slightly negative moves
that residue onto the export register. Configurable in the Configuration tab;
see DOCS.md for the trade-off table.
Behaviour is unchanged at `target_grid_w: 0`.
## 0.2.0
Precedence between strategies is now a first-class object instead of an if/else
ladder, ahead of there being more than three of them.
Every strategy returns a CLAIM each cycle - `set` ("I want X") or `limit` ("the
result must stay within these bounds") - and `arbiter.py` resolves them by one
rule:
1. Highest-priority `set` wins; no claim at all means 0 W.
2. Then every `limit` whose priority is >= that set's priority applies, most
restrictive first.
3. Contradictory limits are a BUG: command 0 W and say so.
Clause 2 is why "money outranks maintenance" is now a consequence of the
priorities rather than a special case in a Jinja template: the maintenance
charge-only limit binds the loop, but will not bind a higher-priority peak
shaving claim when one exists.
- Maintenance shaping (charge-only, cheap-window floor) moved out of the control
law. `control.py` is once again only a controller that tracks the meter.
- The loop computes from the ARBITER's last output, not its own last wish. If
something outranked it, that is what the hardware actually did, and tracking
anything else makes it jump when it regains control.
- Every decision is explainable: "loop -> 0 W, limited by maintenance
(charge-only)" now appears in the UI and the log, instead of a bare number.
- Safety limits (device rating, supervised max_w) bind every strategy including
the highest, and are still enforced a second time at the point of writing.
## 0.1.6
Findings from installing this on a live system, replacing a working YAML
implementation. Every one of these was silent - the add-on looked healthy while
being completely unable to do its job.
- **`run.sh` must use `#!/usr/bin/with-contenv sh`.** The HA base images run
s6-overlay, which starts services with a SANITISED environment. With a plain
shebang, SUPERVISOR_TOKEN is simply absent and every Home Assistant call
returns 401 - while `homeassistant_api: true` makes the permissions look
correctly granted. Startup now logs the token length and probes the Core API,
so the next person sees it in one line.
- **Bump `version:` for every change.** Supervisor keys the built image by
version, so editing source and rebuilding silently reuses the old image. Two
fixes appeared not to work because of this.
- **Dependencies come from apk, not pip.** Alpine is musl and there are no musl
wheels for aiohttp; pip would compile it on the client's Pi.
- **paho-mqtt 1.x and 2.x are both supported.** Alpine ships 1.x, which has no
`CallbackAPIVersion`; that raised and took the whole add-on down with it.
- **MQTT can no longer take down control.** Publisher construction is wrapped -
observability must never stop the controller.
- **MQTT discovery is published from `on_connect`.** paho drops QoS-0 publishes
issued before the CONNACK, so announcing straight after `connect()` published
nothing at all while logging "MQTT connected".
- **Repeated failures log at most once a minute.** The control loop retries every
second; unthrottled warnings rolled the log buffer and destroyed the startup
diagnostics needed to debug the 401 above.
- **`auto_start` works.** The store's defaults supplied `auto: False`, so the
fallback to the option could never fire.
Known issue: after deleting the MQTT entities from the registry during
development, Home Assistant would not re-adopt them from retained discovery -
not even after clearing the retained topics and reconnecting. The add-on
publishes correct discovery and live state (verified on the broker); this is an
HA-side adoption problem and affects status entities only, never control.
## 0.1.0
First packaged release. Ports the control loop and the monthly maintenance
cycle from the reference Home Assistant implementation into an add-on.
- Grid-following control: gain/slew/clamp/deadband with anti-windup, all tuned
against measured hardware behaviour (see FIELD-GUIDE.md §14).
- Saturation freeze **with the duration term** — three consecutive diverging
cycles, not one. The instantaneous test fires on every large correction,
because the plant itself needs 3-6 s to settle.
- Monthly maintenance cycle as an ownership state machine: drain / charge /
hold, with exactly one writer of the setpoint at any moment.
- Capacity-tariff awareness: the maintenance charge is capped by quarter-hour
peak headroom, and peak shaving outranks the maintenance schedule.
- Failsafe behaviour: commands 0 W on missing inputs, on stop, and on shutdown.
Never replays a stale setpoint - the reference implementation did, and the
hardware watchdog cannot catch that.
- Ingress UI with a commissioning checklist that names problems in words.
- Optional MQTT discovery for status entities.
Known limits:
- Home Assistant OS / Supervised only (add-ons cannot run on Container/Core).
- The inverter protocol is reverse-engineered; no vendor contract.
- Without the optional RS485 e-stop, nothing covers the host machine dying.