SAFETY-47: what a shadow run can show, and the watts on its status row #90
@@ -29,6 +29,84 @@ if it has, it needs 0.10.0. Whoever deploys decides.
|
||||
| _this branch_ | TARIFF-16 - the injection leg stops being one number: an injection formula with its own coefficients, its own VAT and no floor under zero |
|
||||
| _this branch_ | SAFETY-45 - a price-driven charge is SIZED by the capacity-tariff guard instead of being switched on and off by it **⚠️ CONTROL STABILITY** |
|
||||
| _this branch_ | SAFETY-10 - shadow mode: the whole decision path runs and nothing reaches the inverter **⚠️ NEW OPTION, DEFAULT-ON FOR A NEW INSTALL** |
|
||||
| _this branch_ | SAFETY-47 - what a shadow run can show you, and the watts on its status row **⚠️ CORRECTS THREE CLAIMS SAFETY-10 SHIPPED** |
|
||||
|
||||
### SAFETY-47 — what a shadow run can show you, and the watts on its status row
|
||||
|
||||
⚠️ **Nothing about the write path changed, and nothing needed to.** Shadow
|
||||
mode still holds every inverter at 0 W through the one writer. What was wrong
|
||||
is what three merged documents **said** a shadow run can show you, and a number
|
||||
on the status page that could be **6.61×** what a live controller would
|
||||
command.
|
||||
|
||||
**A shadow run cannot show you a closed-loop defect. Not partially — not at
|
||||
all.** The battery is held at 0 W, so every measured input — the meter, the
|
||||
billed-quarter accumulator behind it, the battery power, the state of charge —
|
||||
describes a plant that did not respond, and a closed-loop defect is one whose
|
||||
stimulus *is* the plant's response. That is the same property that makes shadow
|
||||
mode safe, so it is not a gap to be closed later: **the closed-loop answer
|
||||
comes from the closed-loop rig or from a live run.**
|
||||
|
||||
SAFETY-10 promised otherwise, because of a sentence that was true when it was
|
||||
written and false one commit later:
|
||||
|
||||
> the **strategies** are unaffected — they ask for a fixed power from inputs
|
||||
> that do not depend on what the battery did — so a shadow run does show you
|
||||
> the trades, the peak-guard engagements and the SoC-limit behaviour.
|
||||
|
||||
SAFETY-45 (above) sizes the buy leg to the billed quarter's charging headroom,
|
||||
and that headroom is `(900 / seconds remaining) × (ceiling − projected)` with
|
||||
the projection read off the **open quarter's meter**. The strategy became
|
||||
closed-loop the day that landed. Measured on the rig, one hour at `peak_cap_w`
|
||||
1500 under a 1200 W house:
|
||||
|
||||
| | live | shadow |
|
||||
|---|---|---|
|
||||
| charge onsets | 28 | **1** |
|
||||
| grid | −455.5 … +3200.0 W | **1200.0 W flat — the house** |
|
||||
| capacity guard engaged | 410 / 720 cycles | **0 / 720** |
|
||||
| state of charge | 50.000019 → 51.856789 % | **50.000000 → 50.000000 %** |
|
||||
|
||||
**What the documents now say.** The exemption narrows to exactly what is still
|
||||
true — **which** hour a strategy picks and **why** are unaffected, because the
|
||||
clock and the price series are not functions of the battery; **how hard** it
|
||||
trades is not. Of the three defects shadow mode was written for, one —
|
||||
TARIFF-14's wrong quarter-hour — is genuinely visible from a shadow run, and it
|
||||
is graded that way: identical live and shadow on 720 of 720 charging cycles at
|
||||
a binding cap.
|
||||
|
||||
**What you will see on the status page.** The `Shadow mode` row and the action
|
||||
log now introduce the watts as what the controller would have commanded **on
|
||||
this cycle** — in every state, because no number a shadow run records is a
|
||||
forecast of a live run. And when a **measured** billed quarter sized those
|
||||
watts, both surfaces carry:
|
||||
|
||||
> ⚠️ AND ITS SIZE CAME FROM THE BILLED-QUARTER METER, WHICH HAS ONLY THE HOUSE
|
||||
> IN IT WHILE THE BATTERY IS HELD AT 0 W. A live run sizes the same trade
|
||||
> against a meter the battery is moving, so this is an UPPER BOUND and not a
|
||||
> prediction; how far under it a live run lands is a closed-loop question and a
|
||||
> shadow run cannot answer it.
|
||||
|
||||
⚠️ **The number is caveated, not re-computed, and that was the decision.**
|
||||
Re-computing it to "look right" would mean the recorded decision was no longer
|
||||
the decision the shipped path reached — while the arbiter, the clamp, the
|
||||
write-authorisation gate, the action log and MQTT all ran on the real one. A
|
||||
shadow run's whole worth is that what it records is what the controller
|
||||
actually decided. `DECISIONS/SAFETY-47-what-a-shadow-run-can-show.md` §3
|
||||
records the three alternatives that were rejected and why.
|
||||
|
||||
⚠️ **On a site whose cap does not bind, nothing changes by one watt.** At
|
||||
`peak_cap_w` 15000 against a 350 W house the recorded figure is the live one
|
||||
exactly, and no caveat is a lie there either — the row still says the size came
|
||||
off a meter with no battery in it, which is true and is the point.
|
||||
|
||||
**And SAFETY-10's own committed evidence could never have failed.** Its
|
||||
comparison table ran at a cap the guard never reaches, *and* read only the
|
||||
first charging sample — the one instant at which the two runs agree even at a
|
||||
cap that does bind. Both had to be closed; closing either alone closes nothing.
|
||||
The table is re-taken across the whole run at a binding cap, and
|
||||
`test_arbitrage.py` part 3d is the CI-side grader so this class cannot recur.
|
||||
14 mutations, no survivors; all 29 check files green.
|
||||
|
||||
### SAFETY-10 — shadow mode, and what its default does to YOUR install
|
||||
|
||||
|
||||
@@ -1,6 +1,12 @@
|
||||
# SAFETY-10 — shadow mode, and why "default-on" is not `true`
|
||||
|
||||
**Status:** decided and implemented on branch `SAFETY-10`.
|
||||
⚠️ **AMENDED BY SAFETY-47, and three of the claims below were false when this
|
||||
was merged.** §5's "the strategies are unaffected" exemption, §4's peak-guard
|
||||
row and §6's evidence table are corrected in place and each correction is
|
||||
marked. The amendments are marked rather than rewritten silently, because what
|
||||
this card believed is part of why the defect shipped. See
|
||||
`DECISIONS/SAFETY-47-what-a-shadow-run-can-show.md`.
|
||||
**Card:** SAFETY-10 — *"Shadow mode (default-on, log-only decisions)"*.
|
||||
**Nothing here reached the inverter.** No deployment, no `ha addons update`, no
|
||||
contact with 192.168.2.158 or 192.168.2.221. Everything below was measured in
|
||||
@@ -26,6 +32,12 @@ the CI image and on TEST-23 stage 3's closed-loop rig.
|
||||
and **latch a trip that survives into live operation and a restart**. §4.
|
||||
4. **The loop leg's shadow decision is one slew step, not a trajectory, and
|
||||
that is a real limitation of this feature.** §5.
|
||||
5. ⚠️ **SAFETY-47: and neither is anything else that depends on the plant
|
||||
answering back. A shadow run cannot surface a closed-loop defect at all**,
|
||||
by the same construction that makes it safe — the battery is held at 0 W, so
|
||||
every measured input describes a plant that did not respond. Of the three
|
||||
defects §"WHAT DEFECT THIS PREVENTS" was written for, exactly one —
|
||||
TARIFF-14's wrong quarter-hour — is visible from a shadow run. §5, §6.
|
||||
|
||||
---
|
||||
|
||||
@@ -130,9 +142,9 @@ shadow run can report *"it would have hit the rating here"*.
|
||||
| surface | what it carries |
|
||||
|---|---|
|
||||
| status banner | `SHADOW MODE - the battery is NOT being controlled...`, **first in the cascade**, amber — red, with the latch named, if one is standing |
|
||||
| status row `Shadow mode` | which rung decided, the watts it **would have commanded**, where the inverter actually is, and `Resolution.explain()` |
|
||||
| status row `Shadow mode` | which rung decided, the watts it **would have commanded on this cycle**, where the inverter actually is, and `Resolution.explain()` — plus, when a measured billed quarter sized those watts, SAFETY-47's caveat saying so (`shadow.SIZED_FROM_METER`) |
|
||||
| status row `Commanded` | `0 W` — the truth, which the row above reconciles with the `Why` row below it |
|
||||
| action log | one line when shadow mode comes on; one line per **change of decision** (winner or rounded watts), carrying the arbiter's own sentence |
|
||||
| action log | one line when shadow mode comes on; one line per **change of decision** (winner, rounded watts, or SAFETY-47's caveat state), carrying the arbiter's own sentence and the same caveat the row carries — `shadow.log_line()` is the one sentence both read |
|
||||
| MQTT | `status: shadow`, its own value, below `failsafe` |
|
||||
|
||||
The action log is **edge**-logged, not level-logged: the log holds 40 rows, and
|
||||
@@ -149,7 +161,7 @@ minutes at the 15 s cycle floor.
|
||||
| SAFETY-03 clamp | **OBSERVES** | Runs on the decision, sets `clamp_last`, logs every engagement. Changes no command |
|
||||
| SAFETY-28 write gate | **OBSERVES** | Same placement, same reason: the question is who chose the number |
|
||||
| SAFETY-18 meter freeze | **OBSERVES**, unchanged | It takes no action live either; both halves of its conjunction are as true in shadow |
|
||||
| SAFETY-07/24/25 peak guard | **OBSERVES** | Level-triggered, unlatched, files its claim as usual — SAFETY-45's limit cycle is visible from a shadow run, which is the point |
|
||||
| SAFETY-07/24/25 peak guard | **OBSERVES, AND SEES ONLY THE HOUSE** | Level-triggered, unlatched, files its claim as usual, so the recorded decision is the real one *for this meter*. ⚠️ **AMENDED BY SAFETY-47.** This row used to end "SAFETY-45's limit cycle is visible from a shadow run, which is the point". It is not: every term of `wanted = batt_w + excess` is measured, and in shadow mode the battery contributes nothing to either. Measured on the rig, same hour, same unsized code — **410 of 720 cycles engaged live, 0 of 720 in shadow** |
|
||||
| SAFETY-31 circulation | **OBSERVES AND MAY LATCH** | Its evidence is *measured* power. Packs pushing against each other while all are told 0 W is a real fault |
|
||||
| SAFETY-42 delivery | **OBSERVES AND MAY LATCH** | Same, against a share that is 0 W |
|
||||
| operator stop | **SUPPRESSED AS A CLAIM, ENFORCED AT THE WIRE** | The one deliberate change. Its `P_SAFETY` 0 W claim out-ranks everything, so leaving it in makes the recorded decision `"stopped"` on every cycle and the run answers the wrong question. The actuator ends at the same number either way, and the wire substitution is **strictly stronger**: a claim can be out-ranked, and it cannot |
|
||||
@@ -186,12 +198,47 @@ is a closed-loop property, it did not happen, and reporting it would be a
|
||||
simulation of a plant that does not exist; three cycles in, such a number
|
||||
describes nothing.
|
||||
|
||||
The strategies are unaffected: arbitrage, the peak guard and maintenance all
|
||||
file `SET` claims at a fixed power from level-triggered inputs. That is why the
|
||||
three defects this card was written for — SAFETY-45's 28 onsets an hour,
|
||||
TARIFF-14's wrong quarter-hour, SAFETY-46's ceiling churn — are all visible from
|
||||
a shadow run, and the loop's ramp is not. Graded, named, in
|
||||
`test_watchdog.py` part 10 as `RECORDED LIMITATION`.
|
||||
⚠️ **AMENDED BY SAFETY-47 — THE PARAGRAPH THAT STOOD HERE WAS THE DEFECT.**
|
||||
It read:
|
||||
|
||||
> The strategies are unaffected: arbitrage, the peak guard and maintenance all
|
||||
> file `SET` claims at a fixed power from level-triggered inputs. That is why
|
||||
> the three defects this card was written for — SAFETY-45's 28 onsets an hour,
|
||||
> TARIFF-14's wrong quarter-hour, SAFETY-46's ceiling churn — are all visible
|
||||
> from a shadow run, and the loop's ramp is not.
|
||||
|
||||
It was true until **SAFETY-45 merged, one commit before this card**. That
|
||||
change makes the buy leg `min(asked, headroom)` with
|
||||
|
||||
```
|
||||
headroom = (900 / remaining) x (ceiling - projected)
|
||||
```
|
||||
|
||||
and `projected` reads the **open quarter's accumulator** — the meter — which is
|
||||
a function of what the battery did earlier in that same quarter. The strategy
|
||||
is closed-loop, and the loop's one-slew-step limitation above is not a special
|
||||
case of anything: **it is the general case**, and the limitation is the whole
|
||||
feature's, not the loop leg's.
|
||||
|
||||
**The correct statement, and it is now graded rather than asserted:**
|
||||
|
||||
> A shadow run cannot surface a **closed-loop** defect — one whose stimulus is
|
||||
> the plant's response to the controller — because the battery is held at 0 W
|
||||
> and there is no response to be the stimulus. **Which** hour a strategy picks
|
||||
> and **why** are unaffected, because the clock and the price series are not
|
||||
> functions of the battery. **How hard** it trades is not.
|
||||
|
||||
Of the three defects this card was written for:
|
||||
|
||||
| | visible from a shadow run? | measured |
|
||||
|---|---|---|
|
||||
| SAFETY-45's limit cycle | **no** | 28 charge onsets live, **1** in shadow; grid −455.5 … +3200.0 W live, **flat at the 1200 W house** in shadow; guard engaged 410/720 live, **0/720** in shadow |
|
||||
| SAFETY-46's SoC churn | **no** | the SoC moves **0.000000000 pp** in a shadow run. No SoC limit can be *reached* in one |
|
||||
| TARIFF-14's wrong quarter-hour | **yes**, and it is the one | which hour, at what price, clearing what spread: identical live and shadow on **720 of 720** charging cycles, at a binding cap |
|
||||
|
||||
Graded in `test_arbitrage.py` part **3d** — the same closed loop part 3c uses,
|
||||
run once live and once in shadow — and the loop leg's own limitation stays
|
||||
named in `test_watchdog.py` part 10 as `RECORDED LIMITATION`.
|
||||
|
||||
---
|
||||
|
||||
@@ -218,22 +265,60 @@ The closed-loop half is `/home/homelab/s10-mut/shadowloop.py` on TEST-23 stage
|
||||
3's rig: the same hour, twice, against `plantsim.Plant` through the firmware's
|
||||
own frame encoder.
|
||||
|
||||
⚠️ **SUPERSEDED BY SAFETY-47 — THE TABLE THAT STOOD HERE COULD NEVER HAVE GONE
|
||||
RED, FOR TWO INDEPENDENT REASONS.** It read `arb_power_w` −2000 W *"identical"*,
|
||||
`arb_reason` *"identical, verbatim"*, arbiter winner *"identical"*, and
|
||||
concluded *"the decision happened, at the same instant, for the same reason, at
|
||||
the same signed power — and the battery did not move."* The battery half is
|
||||
true and is unchanged. The **decision** half was decoration:
|
||||
|
||||
1. **the fixture is `peak_cap_w: 15000` against a 350 W house**, so the
|
||||
capacity guard never engages and SAFETY-45's sizing is in the run and inert.
|
||||
The harness's own comment says so — *"at this scenario's `peak_cap_w: 15000`
|
||||
it is not binding anyway"* — which is MUTATION.md habit 4 written down
|
||||
beside the check it disables;
|
||||
2. **every identity row reads the FIRST charging sample.** At `elapsed = 0`
|
||||
the projection *is* the held level, so the two runs agree to the float there
|
||||
**even at a cap that does bind**. Measured: closing reason (1) alone leaves
|
||||
that comparison passing.
|
||||
|
||||
Both had to be closed. Re-taken below at **`peak_cap_w` 1500 / house 1200 /
|
||||
`max_w` 2000**, one hour at a 5 s cycle, **across the whole run** — harness
|
||||
`/home/homelab/s47-mut/shadowloop47.py`, same rig, same three transcribed
|
||||
lines.
|
||||
|
||||
| | live | shadow |
|
||||
|---|---|---|
|
||||
| `plant_cmd_w` | −2000 W throughout | **0 W throughout** |
|
||||
| `batt_w` | −2000 .. −40.6 W | **0.0 W, exactly** |
|
||||
| SoC | 50.000 → **62.331 %** | 50.0 → **50.0 %** |
|
||||
| grid | 390.6 .. 2350 W | **350 W = the house, exactly** |
|
||||
| `ARBITRAGE_CHARGE` samples | 3600 | **3600** |
|
||||
| first charge instant | 2026-01-15T00:00:00+00:00 | **identical** |
|
||||
| `arb_power_w` | −2000 W | **identical** |
|
||||
| `arb_reason` | the strategy's own sentence | **identical, verbatim** |
|
||||
| grid | 1224.1 … 1506.0 W — **held up at the ceiling** | **1200.0 W flat = the house, exactly** |
|
||||
| SoC | 50.000019 → **51.856789 %** | 50.000000 → **50.000000 %** |
|
||||
| `ARBITRAGE_CHARGE` cycles | 720 / 720 | **720 / 720** |
|
||||
| first charging cycle, `arb_power_w` | −300.0000 W | **identical — and this is why the old table passed** |
|
||||
| `arb_power_w`, **whole run** | −307.799 … −299.930 W | **−2000.000 … −300.000 W** |
|
||||
| …cycles where the two differ | — | **716 of 720** |
|
||||
| `arb_reason`, whole run | the strategy's own sentence | **differs on 719 of 720** |
|
||||
| measured charging headroom | 299.93 … 307.80 W | **300.0 … 54 000.0 W** |
|
||||
| final recorded command | **−302.4 W** | **−2000.0 W — 6.61× the live figure** |
|
||||
| price / spread / which hour | | **identical on 720 of 720** |
|
||||
| arbiter winner | `arbitrage` | **identical** |
|
||||
|
||||
The decision happened, at the same instant, for the same reason, at the same
|
||||
signed power — and the battery did not move.
|
||||
**What the re-taken table says.** The decision still *happens*, at the same
|
||||
instant, on the same hour, at the same price, for the same *kind* of reason,
|
||||
and the battery still does not move — those were the card's real claims and
|
||||
they hold. What does **not** hold is that the decision is the *same decision*:
|
||||
its **size** is a function of a meter the battery never moved, and at this cap
|
||||
the recorded figure is 6.61× what a live controller commands. 54 000 W of
|
||||
"headroom" under a 1500 W ceiling is `900/remaining` multiplying a gap the
|
||||
battery never closed.
|
||||
|
||||
⚠️ **Three lines of that harness are a TRANSCRIPTION and are marked as one.**
|
||||
⚠️ **And the SoC row is the second half of it.** 0.000000000 pp of movement is
|
||||
not a curiosity: it is the proof that **no SoC-limit behaviour is reachable
|
||||
from a shadow run at all**, which §5 used to promise.
|
||||
|
||||
SAFETY-47 puts the caveat on both surfaces that carry the number and narrows
|
||||
the three documents' claims; `test_arbitrage.py` part 3d is the CI-side grader
|
||||
so this class cannot recur.
|
||||
|
||||
⚠️ **Three lines of each harness are a TRANSCRIPTION and are marked as one.**
|
||||
`priceloop.Rig` has no `_write_unit()`, no clamp and no failsafe machine
|
||||
(divergence 2 of its README), so the substitution's **placement** is
|
||||
transcribed there. The shipped placement is graded by `test_clamp.py` part 8,
|
||||
|
||||
@@ -0,0 +1,319 @@
|
||||
# SAFETY-47 — what a shadow run can show, and what it cannot
|
||||
|
||||
**Status:** decided and implemented on branch `SAFETY-47`.
|
||||
**Card:** SAFETY-47 — *"shadow mode's claims, and the number on the status
|
||||
row"*.
|
||||
**Nothing here reached the inverter.** No deployment, no `ha addons update`, no
|
||||
contact with 192.168.2.158 or 192.168.2.221. Everything below was measured in
|
||||
the CI image and on TEST-23 stage 3's closed-loop rig.
|
||||
|
||||
⚠️ **This is not a write-path defect and nothing in the write path was
|
||||
touched.** SAFETY-10's substitution, re-seed, authorisation gate and clamp are
|
||||
unchanged. What was wrong is what three merged documents **say** a shadow run
|
||||
can show you, and a number on the status row that can be **6.61×** what a live
|
||||
controller would command.
|
||||
|
||||
---
|
||||
|
||||
## 0. The four things a reader should take away
|
||||
|
||||
1. **Shadow mode cannot surface a closed-loop defect. Not partially — not at
|
||||
all**, and by the same construction that makes it safe. §1.
|
||||
2. **The "strategies are unaffected" exemption was true until SAFETY-45 merged,
|
||||
one commit before SAFETY-10.** Sizing the buy leg to the billed-quarter
|
||||
headroom made the strategy closed-loop. §2.
|
||||
3. **The recorded watts are the right answer to a question nobody asked, and
|
||||
they are CAVEATED rather than re-computed.** Re-computing would mean the
|
||||
recorded decision was no longer the decision the shipped path reached, which
|
||||
is the one thing shadow mode has to be able to say. §3 records what was
|
||||
rejected.
|
||||
4. **SAFETY-10 §6's committed evidence could never have failed, for two
|
||||
independent reasons, and closing either one alone closes nothing.** §4.
|
||||
|
||||
---
|
||||
|
||||
## 1. Why the answer is "not at all", and not "not very well"
|
||||
|
||||
Shadow mode holds every actuator at `shadow.WIRE_W` and re-seeds the carried
|
||||
command to it at the end of each cycle. So every **measured** input — the
|
||||
meter, the billed-quarter accumulator behind it, the battery power, the state
|
||||
of charge — describes a plant that **did not respond**.
|
||||
|
||||
A closed-loop defect is, by definition, one whose stimulus **is** the plant's
|
||||
response to the controller. No response, no stimulus, nothing to see. This is
|
||||
not an implementation gap:
|
||||
|
||||
* feeding the guards a **simulated** plant instead is exactly what SAFETY-10 §4
|
||||
refuses for the sign watchdogs, and the reason generalises — a controller
|
||||
reacting to a plant that does not exist drifts further from reality every
|
||||
tick, and three cycles in its numbers describe nothing;
|
||||
* and SAFETY-10 §5 already conceded the same fact for the grid-following loop
|
||||
("one slew step, not a trajectory"). That was never a property of the loop.
|
||||
**It is the general case**, and the loop leg was simply where it had already
|
||||
been noticed.
|
||||
|
||||
**So the closed-loop answer comes from a closed-loop rig (TEST-23 stage 3) or
|
||||
from a live run. There is no third place, and saying that plainly is worth more
|
||||
than the three sentences it replaces.**
|
||||
|
||||
### Measured, on the rig, at a cap that binds
|
||||
|
||||
`peak_cap_w` 1500 / house 1200 / `max_w` 2000, one hour at a 5 s cycle. Of the
|
||||
three defects SAFETY-10 was written for:
|
||||
|
||||
| | visible? | measured |
|
||||
|---|---|---|
|
||||
| SAFETY-45's limit cycle | **no** | 28 charge onsets live, **1** in shadow. Grid −455.5 … +3200.0 W live, **flat at the 1200 W house** in shadow. Guard engaged 410/720 cycles live, **0/720** in shadow. (Taken with SAFETY-45 reverted — that is the defect being looked for.) |
|
||||
| SAFETY-46's SoC churn | **no** | the SoC moves **0.000000000 pp** in a shadow run. The SoC is the pack's integral of what the pack was commanded, and it was commanded 0 W. No SoC limit can be *reached* in a shadow run at all |
|
||||
| TARIFF-14's wrong quarter-hour | **yes**, and it is the only one | the price lookup's inputs are the clock and the price series, neither a function of the battery. Which hour, at what price, clearing what spread: **identical live and shadow on 720 of 720 charging cycles, at a binding cap** |
|
||||
|
||||
### What a shadow run genuinely is for
|
||||
|
||||
*Which* strategy wins, on *which* hour, at *which* price, for *which* reason,
|
||||
against which limits — the wrong-quarter-hour class, a trade armed on a day it
|
||||
should not be, a refusal whose sentence names the wrong subsystem, a clamp that
|
||||
would have engaged, a standing failsafe latch. That is a real and useful set,
|
||||
and it is the set the documents now claim.
|
||||
|
||||
---
|
||||
|
||||
## 2. The exemption, and exactly how much of it survives
|
||||
|
||||
All three documents carried a version of:
|
||||
|
||||
> The **strategies** are unaffected — price arbitrage, the capacity guard and
|
||||
> maintenance all ask for a fixed power **from inputs that do not depend on
|
||||
> what the battery did**.
|
||||
|
||||
**True before SAFETY-45, false after it.** SAFETY-45 makes the buy leg
|
||||
`min(asked, headroom)`, and
|
||||
|
||||
```
|
||||
headroom = (900 / remaining) x (ceiling - projected)
|
||||
```
|
||||
|
||||
where `projected` reads the **open quarter's accumulator** — the meter — which
|
||||
is a function of what the battery did earlier in that same quarter. SAFETY-45
|
||||
merged one commit before SAFETY-10, so the exemption was stale on the day it
|
||||
was written.
|
||||
|
||||
**What survives, and it is now graded rather than asserted:**
|
||||
|
||||
> **Which** hour a strategy picks, and **why**, are unaffected — the clock and
|
||||
> the price series are not functions of the battery.
|
||||
> **How hard** it trades is not.
|
||||
|
||||
⚠️ **The peak guard is not in the surviving half either.** Every term of
|
||||
`wanted = batt_w + excess` is measured, so in a shadow run the guard engages
|
||||
only if the *house alone* would put the quarter over the ceiling. Its
|
||||
**ceiling** and its **reasons** are worth reading from a shadow run; its
|
||||
**engagements** are not evidence of anything.
|
||||
|
||||
---
|
||||
|
||||
## 3. The number on the status row — decided, and what was rejected
|
||||
|
||||
At `peak_cap_w` 1500 under a 1200 W house the status row read **"WOULD HAVE
|
||||
COMMANDED −2 000 W"**. A live controller commands **−302.4 W**. Measured on the
|
||||
shipped build:
|
||||
|
||||
| cap / house | live commanded | shadow recorded | over by |
|
||||
|---|---|---|---|
|
||||
| 1500 / 1200 | −302.4 W | **−2000.0 W** | **6.61×** |
|
||||
| 3500 / 3000 | −502.6 W | −2000.0 W | 3.98× |
|
||||
| 3500 / 2000 *(shipped cap)* | −1502.6 W | −2000.0 W | 1.33× |
|
||||
| 3500 / 1800 | −1702.6 W | −2000.0 W | 1.17× |
|
||||
| 15000 / 350 | −2000.0 W | −2000.0 W | 1.00× |
|
||||
|
||||
⚠️ **The arithmetic is not wrong.** `900/remaining` is correct for a meter that
|
||||
is genuinely under the ceiling, and in a shadow run the meter genuinely *is*
|
||||
under it, because the battery is not charging. **The recorded number is the
|
||||
right answer to a question nobody asked** — and the last row of that table is
|
||||
the fixture SAFETY-10's own evidence was taken on, which is why nothing
|
||||
reported it.
|
||||
|
||||
### What shipped
|
||||
|
||||
1. **Unconditionally**, the row and the log line stop forecasting: the watts
|
||||
are introduced as what would have been commanded **ON THIS CYCLE**. No
|
||||
number a shadow run records is a prediction of a live run, so no state
|
||||
should read like one.
|
||||
2. **Conditionally**, whenever a **measured** billed quarter sized the number
|
||||
being recorded, both surfaces carry `shadow.SIZED_FROM_METER`:
|
||||
|
||||
> ⚠️ AND ITS SIZE CAME FROM THE BILLED-QUARTER METER, WHICH HAS ONLY THE
|
||||
> HOUSE IN IT WHILE THE BATTERY IS HELD AT 0 W. A live run sizes the same
|
||||
> trade against a meter the battery is moving, so this is an UPPER BOUND and
|
||||
> not a prediction; how far under it a live run lands is a closed-loop
|
||||
> question and a shadow run cannot answer it.
|
||||
|
||||
⚠️ **"Upper bound", and not "smaller", and the difference was measured.**
|
||||
Charging only *adds* offtake, so a live `projected` is never below a shadow one
|
||||
and the headroom never above it — with **equality at the start of every
|
||||
quarter**, where `900/remaining` is 1.0 and neither plant has moved. Measured
|
||||
pairwise over 3600 charging cycles in five configurations: **0 cycles below,
|
||||
730 exactly equal.** A sentence reading "smaller" would have been false on
|
||||
every one of those 730, and the first draft of this card said "smaller".
|
||||
|
||||
⚠️ **And it names no factor.** How far under the bound a live run lands is a
|
||||
property of the site. A number invented for the row would be a second helping
|
||||
of the defect the sentence exists to disclose.
|
||||
|
||||
⚠️ **The predicate is NOT keyed on whether the trade was capped, and that is
|
||||
the trap this card nearly walked into.** `arbitrage`'s own sentence says *"SIZED
|
||||
BY THE CAPACITY-TARIFF GUARD"* only when the headroom came out **below** the
|
||||
ask — which in a shadow run is the **start** of the quarter, where the two runs
|
||||
still agree to the float. By the end, `900/remaining` has multiplied the
|
||||
headroom **past** the ask, the trade is **not** capped, the sentence is silent,
|
||||
and the recorded number is at its **most** wrong. A caveat keyed on it would be
|
||||
quietest exactly where it is needed loudest. `arbitrage.sized_from_meter()` is
|
||||
keyed on the headroom having been **measured**, so it fires on both.
|
||||
`test_arbitrage.py` part 3d-8 drives the inversion.
|
||||
|
||||
### Rejected, and why
|
||||
|
||||
* **Re-compute the number so it does not amplify** — e.g. record
|
||||
`ceiling − projected` (gain 1.0) instead of the sized figure. It matches the
|
||||
live answer almost exactly at this cap, and it is the **worst** of the
|
||||
options. It would be a **shadow-only sizing**: the recorded decision would no
|
||||
longer be the decision the shipped path reached, while the arbiter, the
|
||||
clamp, SAFETY-28's gate, the action log and MQTT all ran on the real one. A
|
||||
second copy of the sizing arithmetic living in the display layer is
|
||||
MUTATION.md's transcribed-predicate defect on an operator-facing surface, and
|
||||
it generalises to no other strategy. SAFETY-10's whole safety argument is
|
||||
that shadow mode is a **substitution at the wire**, not a second controller;
|
||||
this would have made it a second controller everywhere except the wire.
|
||||
* **Record nothing where the sizing depends on measured state.** Tempting —
|
||||
"no number beats a number 6.61× out". Rejected on three counts: it blanks the
|
||||
row exactly when arbitrage is trading, which is when a commissioning engineer
|
||||
most wants it; the action log's edge key is the rounded watts, so blanking
|
||||
them either floods or silences the log; and a surface that flickers between a
|
||||
number and a dash is harder to read than a number with a standing caveat.
|
||||
The narrow version of this — dropping the watts only — was the closest
|
||||
runner-up.
|
||||
* **Record the unsized ask alongside the sized one.** It adds a number without
|
||||
adding a warning. The unsized ask is `max_w`, a constant the operator
|
||||
configured; on the shipped 3500/2000 row both figures are 2000 W, so the pair
|
||||
is exactly as misleading as the single figure was.
|
||||
* **A caveat on every cycle in every state.** Rejected as the *whole* answer,
|
||||
accepted as half of it: the unconditional part is a two-word narrowing of the
|
||||
verb ("on this cycle"), not a warning, and the warning proper is conditional
|
||||
so that it still means something when it appears.
|
||||
|
||||
---
|
||||
|
||||
## 4. SAFETY-10 §6's evidence, and why it could not fail
|
||||
|
||||
§6 tabulated `arb_power_w` −2000 W *"identical"*, `arb_reason` *"identical,
|
||||
verbatim"*, arbiter winner *"identical"*. Two independent reasons it could
|
||||
never have gone red:
|
||||
|
||||
1. **the fixture is `peak_cap_w: 15000` against a 350 W house**, so the guard
|
||||
never engages and SAFETY-45's sizing is in the run and inert. ⚠️ **The
|
||||
harness's own comment says so** — *"at this scenario's `peak_cap_w: 15000`
|
||||
it is not binding anyway"* — which is MUTATION.md habit 4 written down
|
||||
beside the check it disables;
|
||||
2. **every identity row reads the FIRST charging sample.** At `elapsed = 0` the
|
||||
projection *is* the held level, so the two runs agree to the float there
|
||||
**even at a cap that does bind**.
|
||||
|
||||
⚠️ **AND THAT SECOND REASON IS THE ONE A REVIEWER CANNOT SEE FROM A DIFF.**
|
||||
Widening the fixture alone — the obvious fix — leaves the `[0]` comparison
|
||||
passing. Measured, not reasoned: at 1500/1200 the first charging cycle is
|
||||
−300.0000 W in **both** runs while 716 of the 720 cycles differ. Part 3d-2
|
||||
grades that agreement **as an expectation**, so nobody rebuilds a check on
|
||||
`[0]` believing it covers something.
|
||||
|
||||
This is habit 4's **twelfth** instance in this repository, its **second**
|
||||
inside a committed evidence artifact, and — like the seventh and the eleventh —
|
||||
it was in a **measuring instrument** rather than in a check.
|
||||
|
||||
§6 is re-taken at `peak_cap_w` 1500 / house 1200 / `max_w` 2000, across the
|
||||
whole run. Harness `/home/homelab/s47-mut/shadowloop47.py`.
|
||||
|
||||
---
|
||||
|
||||
## 5. The grader, so this class cannot recur
|
||||
|
||||
`test_arbitrage.py` part **3d** — placed beside part 3c, which is SAFETY-45's
|
||||
own closed-loop regression, and built on the **same** `s45_loop()` harness so
|
||||
the two runs share every line of shipped code and differ in **one argument**:
|
||||
|
||||
```
|
||||
s45_loop(sized=True) the live hour
|
||||
s45_loop(sized=True, shadow=True) the same hour, battery held at WIRE_W
|
||||
s45_loop(sized=False, shadow=True) SAFETY-45's own defect, watched from
|
||||
inside shadow mode
|
||||
```
|
||||
|
||||
Three lines of `s45_loop()` stand in for `Controller._write_unit()`'s
|
||||
substitution and `_shadow_settle()`'s record and re-seed. They are marked as a
|
||||
**transcription**; `test_clamp.py` part 8 is the check on the shipped
|
||||
placement, and it drives the real `Controller`. Everything that produces a
|
||||
number — the averager, the projection, the guard, the headroom, the strategy,
|
||||
the arbiter, the row and the log sentence — is the shipped one.
|
||||
|
||||
What 3d grades, in order: that the cap **binds** (the precondition the old
|
||||
evidence lacked); that the first charging cycle agrees **anyway**; that the
|
||||
whole run diverges, and by how much; that the record is an **upper bound**, and
|
||||
the two-point arithmetic that makes it one; what survives of the exemption;
|
||||
that SAFETY-45's limit cycle and the guard's engagements are **not** visible;
|
||||
the four rungs of `sized_from_meter()`, each reached with the other three clear
|
||||
(TEST-16); both operator surfaces; the `capped`-keying trap; and main.py's
|
||||
three call sites, pinned on the AST.
|
||||
|
||||
⚠️ **The section carries its own precondition into every check.** A mutation
|
||||
that stops either run trading left the lists empty, the first `min()` raised,
|
||||
the file died before part 4 and the run reported **zero reds — which reads
|
||||
exactly like a survivor**. That is FCST-06's shape and it was **driven**, not
|
||||
imagined. `s47check()` now fails every check in the section when the stimulus
|
||||
was not produced, and the one division in it answers `nan` rather than raising.
|
||||
|
||||
---
|
||||
|
||||
## 6. The mutation battery — 14 mutations, no survivors
|
||||
|
||||
Harness `/home/homelab/s47-mut/run.py`, backups inside it. Each run restores
|
||||
from backup, purges `__pycache__` **on the host**, and grades through the CI
|
||||
image with the tree bind-mounted `:ro`, so the interpreter cannot write a cache
|
||||
into the tree under test (TEST-15). Fingerprints are printed before the first
|
||||
run and re-checked after the last restore.
|
||||
|
||||
| # | mutation | file | Δ | reds |
|
||||
|---|---|---|---|---|
|
||||
| M1 | the row drops the caveat branch | `shadow.py` | −63 B | 2 |
|
||||
| M2 | **the trap**: `sized_from_meter()` keyed on the trade being CAPPED — silent where the record is multiples out | `arbitrage.py` | +33 B | 5 |
|
||||
| M3 | the CHARGE rung dropped — a sell carries a caveat §9.1 makes false | `arbitrage.py` | −30 B | 1 |
|
||||
| M4 | the measured-headroom rung dropped | `arbitrage.py` | −18 B | 1 |
|
||||
| M5 | the arbiter-winner rung dropped — a caveat on somebody else's number | `arbitrage.py` | −33 B | 1 |
|
||||
| M6 | `main.py` renders the row with `sized_from_meter=False` | `main.py` | −23 B | 1 |
|
||||
| M7 | `main.py` drops `winner=` — the rung exists and is never reached | `main.py` | −1 B | 1 |
|
||||
| M8 | `main.py` sizes the trade from a literal — SAFETY-45 out of the shipped path, which the hoist put at risk | `main.py` | −41 B | 2 |
|
||||
| M9 | the headroom assignment moves out of `cycle()` | `main.py` | −39 B | 1 |
|
||||
| M10 | `sized_from_meter` gains a `False` default (TEST-14) | `shadow.py` | +8 B | 1 |
|
||||
| M11 | `ON THIS CYCLE` deleted — the row forecasts again | `shadow.py` | −14 B | 1 |
|
||||
| M12 | `log_line()` drops the caveat — the page discloses, the record does not | `shadow.py` | −63 B | 2 |
|
||||
| M13 ⚠️ | `main.py` re-assembles the log sentence at the call site | `main.py` | **+0 B** | 1 |
|
||||
| M14 ⚠️ | `wanted = batt_w − excess` — the headroom stops being monotone in the battery and the row's UPPER BOUND sentence becomes false | `peakguard.py` | **+0 B** | 38 |
|
||||
|
||||
**Survivors: none.**
|
||||
|
||||
⚠️ **M13 and M14 are `+0 B`, which MUTATION.md names as the risky delta.** Both
|
||||
were confirmed on disk by `sha256` before the run started — the harness prints
|
||||
the fingerprint of every graded file and the hash moved for each — and every
|
||||
run is purged, so neither is at risk of the stale-`.pyc` failure.
|
||||
|
||||
⚠️ **Two findings from driving it, both reported rather than tidied away.**
|
||||
|
||||
* **M14's first form was aimed at the wrong direction and correctly survived.**
|
||||
`min` → `max` in the buy leg's sizing makes the shadow record *larger*, which
|
||||
is still an upper bound, so 3d-3b was right not to fail. The mutation that
|
||||
actually inverts the bound is the sign of the excess term in `wanted`. A
|
||||
survivor that is right is worth more than a red aimed at the wrong claim.
|
||||
* **M12 was a survivor before the fix it forced.** Deleting the caveat from the
|
||||
action-log line left **all 29 files green**: the only check that could see
|
||||
that line drives a fixture with `meter_source: off`, where no arbitrage
|
||||
decision — and therefore no caveat — is reachable. The sentence was an
|
||||
f-string inside `Controller._shadow_settle()`, i.e. a surface no check could
|
||||
grade. It is `shadow.log_line()` now, for the reason `words()` is a function,
|
||||
and M13 is the mutation that puts it back at the call site.
|
||||
+88
-14
@@ -650,8 +650,9 @@ decisions recorded while the loop runs.
|
||||
|
||||
**What you get out of it.** The status page carries a red-amber banner saying
|
||||
the battery is not being controlled, a `Shadow mode` row saying which rung
|
||||
decided, what it **would have commanded** and why, and the `Why` row with the
|
||||
arbiter's own sentence. The action log gets one line each time the decision
|
||||
decided, what it **would have commanded on that cycle** and why — with the
|
||||
caveat below, where the number was sized from a meter the battery never
|
||||
moved — and the `Why` row with the arbiter's own sentence. The action log gets one line each time the decision
|
||||
changes — the winner or the watts — rather than one per cycle, so a 40-row log
|
||||
still contains the context of what it found. MQTT reports `status: shadow`.
|
||||
|
||||
@@ -663,7 +664,12 @@ never saw it, and **latch a trip that survives into live operation and a
|
||||
restart**. The clamp (SAFETY-03), the write-authorisation gate (SAFETY-28), the
|
||||
frozen-meter alarm (SAFETY-18) and the capacity guard all **observe**: they run
|
||||
on the number the decision path produced, so a shadow run can tell you the
|
||||
clamp would have engaged. The circulation (SAFETY-31) and delivery (SAFETY-42)
|
||||
clamp would have engaged. ⚠️ **The capacity guard observes a meter with no
|
||||
battery in it.** Every term of the quantity it thresholds is measured, so it
|
||||
engages in a shadow run only if the *house alone* would have put the quarter
|
||||
over the ceiling — 410 engaged cycles live against 0 in shadow, on the hour
|
||||
tabulated below. Its *ceiling* and its *reasons* are worth reading from a
|
||||
shadow run; its *engagements* are not evidence of anything. The circulation (SAFETY-31) and delivery (SAFETY-42)
|
||||
watchdogs observe and may legitimately latch, because their evidence is
|
||||
*measured* power, not a command. The operator stop is enforced at the wire
|
||||
instead of as a claim, so that the recorded decision is the real one.
|
||||
@@ -678,17 +684,85 @@ every cycle whether control is started or not, so they already run against a
|
||||
battery that does not move on a stopped install. Shadow mode inherits that
|
||||
exactly; it neither improves it nor makes it worse.
|
||||
|
||||
⚠️ **What a shadow run will NOT tell you.** The controller's carried command is
|
||||
re-seeded to the 0 W standing on the wire at the end of every shadow cycle —
|
||||
that is what makes turning shadow mode off safe, because the loop then resumes
|
||||
from where the battery actually is. The consequence is that the
|
||||
**grid-following loop's** recorded decision is **one slew step** and stays
|
||||
there: a shadow run answers *"what would it command now"*, not *"what
|
||||
trajectory would it have followed"*, because the trajectory depends on a
|
||||
battery responding and none did. The **strategies** are unaffected — price
|
||||
arbitrage, the capacity guard and maintenance all ask for a fixed power from
|
||||
inputs that do not depend on what the battery did — so a shadow run does show
|
||||
you the trades, the peak-guard engagements and the SoC-limit behaviour.
|
||||
⚠️ **What a shadow run will NOT tell you — and it is a whole category, not a
|
||||
footnote.** The controller's carried command is re-seeded to the 0 W standing
|
||||
on the wire at the end of every shadow cycle — that is what makes turning
|
||||
shadow mode off safe, because the loop then resumes from where the battery
|
||||
actually is. Everything below follows from the same fact.
|
||||
|
||||
**A shadow run cannot show you a closed-loop defect. Not partially — not at
|
||||
all.** The battery is held at 0 W, so every *measured* input — the meter, the
|
||||
billed-quarter accumulator behind it, the battery power, the state of charge —
|
||||
describes a plant that did not respond. A closed-loop defect is one whose
|
||||
stimulus **is** the plant's response, and there is no response to be the
|
||||
stimulus. This is not a gap waiting to be closed: feeding the guards a
|
||||
simulated plant instead is exactly what the sign-watchdog decision below
|
||||
refuses, and for the same reason — a controller reacting to a plant that does
|
||||
not exist drifts further from reality every tick. **The closed-loop answer
|
||||
comes from the closed-loop rig or from a live run, and there is no third
|
||||
place.**
|
||||
|
||||
Concretely, measured on the rig at `peak_cap_w` 1500 under a 1200 W house,
|
||||
`max_w` 2000, one hour at a 5 s cycle — the same hour run twice, live and in
|
||||
shadow, on the same code:
|
||||
|
||||
| | live | shadow |
|
||||
|---|---|---|
|
||||
| charge onsets in the hour | **28** | **1** |
|
||||
| grid | **−455.5 … +3200.0 W** | **1200.0 W flat — the house** |
|
||||
| capacity guard engaged | **410 / 720 cycles** | **0 / 720** |
|
||||
| state of charge | 50.000019 → 51.856789 % | **50.000000 → 50.000000 %** |
|
||||
|
||||
(The onset and engagement figures are taken with the trade-sizing fix reverted,
|
||||
because that is the defect being looked for; the SoC and grid figures are the
|
||||
shipped build.)
|
||||
|
||||
⚠️ **The "strategies are unaffected" exemption that used to stand here was true
|
||||
until the trade-sizing fix landed, and is now false by hours.** That fix makes
|
||||
the buy leg `min(asked, headroom)`, where the headroom is
|
||||
`(900 / seconds remaining) × (ceiling − projected quarter average)` — and the
|
||||
projection reads the **open quarter's accumulator**, i.e. the meter, i.e. a
|
||||
function of what the battery did earlier in that same quarter. What survives
|
||||
of the exemption is exactly this much:
|
||||
|
||||
> **Which** hour a strategy picks, and **why**, are unaffected — the clock and
|
||||
> the price series are not functions of the battery. Measured: identical live
|
||||
> and shadow on 720 of 720 charging cycles at a binding cap. **How hard** it
|
||||
> trades is not.
|
||||
|
||||
⚠️ **So the watts on the `Shadow mode` row are the right answer to a question
|
||||
nobody asked, and the row now says so.** In a shadow run the billed quarter
|
||||
really *is* under its ceiling, because the battery really *is* not charging, so
|
||||
`900 / remaining` multiplies a gap a live run would have closed. On the same
|
||||
rig, shipped code:
|
||||
|
||||
| cap / house | live commanded | shadow recorded | over by |
|
||||
|---|---|---|---|
|
||||
| 1500 / 1200 | −302.4 W | **−2000.0 W** | **6.61×** |
|
||||
| 3500 / 3000 | −502.6 W | −2000.0 W | 3.98× |
|
||||
| 3500 / 2000 *(shipped cap)* | −1502.6 W | −2000.0 W | 1.33× |
|
||||
| 3500 / 1800 | −1702.6 W | −2000.0 W | 1.17× |
|
||||
| 15000 / 350 | −2000.0 W | −2000.0 W | 1.00× |
|
||||
|
||||
Whenever a measured billed quarter sized the number, the row and the action log
|
||||
carry **⚠️ AND ITS SIZE CAME FROM THE BILLED-QUARTER METER, WHICH HAS ONLY THE
|
||||
HOUSE IN IT WHILE THE BATTERY IS HELD AT 0 W** — and the watts are introduced
|
||||
as what it would have commanded **on this cycle**, in every state, because no
|
||||
number a shadow run records is a forecast of a live one. The figure is **not**
|
||||
re-computed to look right: a shadow-only sizing would mean the recorded
|
||||
decision was no longer the decision the shipped path reached, which is the one
|
||||
thing this feature has to be able to say.
|
||||
|
||||
The **grid-following loop** is the same story told first: its recorded decision
|
||||
is **one slew step** and stays there, because a trajectory depends on a battery
|
||||
responding and none did.
|
||||
|
||||
**What a shadow run genuinely is for**, then: *which* strategy wins, on *which*
|
||||
hour, at *which* price, for *which* reason, against which limits — the
|
||||
wrong-quarter-hour class of defect, a trade armed on a day it should not be, a
|
||||
refusal whose sentence names the wrong subsystem, a clamp that would have
|
||||
engaged, a standing failsafe latch. That is a real and useful set, and it is
|
||||
the set this feature covers.
|
||||
|
||||
#### The sign-disagreement failsafe
|
||||
|
||||
|
||||
@@ -172,7 +172,7 @@ manufactures them from a **fixture**: the check runs, the assertion is
|
||||
evaluated, the sentence above it is true — and the numbers it compares are
|
||||
arranged so that the failure it describes could not have changed the answer.
|
||||
|
||||
It is not hypothetical and it is not rare. ELEVEN instances in two weeks; four
|
||||
It is not hypothetical and it is not rare. TWELVE instances in two weeks; four
|
||||
were found by review, two - CFG-04's fixture pair - by an author's own mutation
|
||||
battery, which is the cheaper place, one by review again, in the one
|
||||
place nobody had thought to point the rule at: not a check in the suite, but a
|
||||
@@ -414,6 +414,44 @@ same place twice, the check is decoration.
|
||||
|
||||
The general habits are **14** and **15** below.
|
||||
|
||||
* ⚠️ **SAFETY-47 IS THE TWELFTH, AND IT IS THE SECOND INSIDE A COMMITTED
|
||||
EVIDENCE ARTIFACT.** `DECISIONS/SAFETY-10-shadow-mode.md` §6 tabulated a live
|
||||
run and a shadow run agreeing on `arb_power_w`, on the reason **verbatim**
|
||||
and on the arbiter's winner, and concluded that shadow mode reaches the same
|
||||
decision. **Two independent reasons it could not have gone red, and closing
|
||||
either one alone closes nothing:**
|
||||
* its fixture is `peak_cap_w: 15000` against a 350 W house, so the capacity
|
||||
guard never engages and the thing whose invariance is being claimed —
|
||||
SAFETY-45's sizing of the buy leg from the billed-quarter meter — is in the
|
||||
run and **inert**. ⚠️ **The harness's own comment says so**: *"at this
|
||||
scenario's `peak_cap_w: 15000` it is not binding anyway"*. The rule was
|
||||
written down beside the check it disabled and nobody read it as a
|
||||
disclosure;
|
||||
* and every identity row reads `_sa[0]`/`_la[0]` — **the first charging
|
||||
sample**. At `elapsed = 0` the projection **is** the held level, so the two
|
||||
runs agree **to the float even at a cap that does bind**. Measured:
|
||||
widening the fixture alone — the obvious fix — leaves that comparison
|
||||
passing.
|
||||
|
||||
⚠️ **THE SECOND REASON IS A NEW SHAPE FOR THIS LIST: AN INDEX, NOT A
|
||||
FIXTURE.** Ask of every identity claim not only *"could this data differ"*
|
||||
but *"**at the point I sampled it**, could it differ yet"*. A comparison
|
||||
taken at `t = 0` between two runs that diverge **because one of them acts**
|
||||
is a comparison of a plant with itself, and no amount of widening the fixture
|
||||
changes that. The replacement, `test_arbitrage.py` part 3d, grades the whole
|
||||
run — 716 of 720 charging cycles differ — and grades the `[0]` agreement **as
|
||||
an expectation**, so nobody rebuilds a check on it believing it covers
|
||||
something.
|
||||
|
||||
⚠️ **AND THE FIX'S OWN FIRST DRAFT CARRIED A THIRTEENTH.** The new part's
|
||||
action-log check could not reach the log line at all: the sentence was an
|
||||
f-string inside `Controller._shadow_settle()`, and the only suite that drives
|
||||
that method uses a `meter_source: off` fixture where no arbitrage decision —
|
||||
and therefore no caveat — exists. Deleting the caveat from it left **all 29
|
||||
files green**. It is `shadow.log_line()` now. *A sentence assembled at a call
|
||||
site is a sentence no check can grade*, which is CFG-04's substring lesson
|
||||
arriving from the other direction.
|
||||
|
||||
Note what these have in common with a masked rung: the mutation *runs*, and the
|
||||
suite is *honestly* green. Nothing in a purge, a fingerprint or a disassembly
|
||||
can see it, because the code under test really did behave identically on the
|
||||
|
||||
@@ -471,6 +471,67 @@ def _act(plan, now, v, soc, charge_w, discharge_w, floor_pct, ceiling_pct,
|
||||
price_now_eur_kwh=price)
|
||||
|
||||
|
||||
def sized_from_meter(decision: ArbitrageDecision, headroom_w, *,
|
||||
winner: str | None) -> bool:
|
||||
"""SAFETY-47. Was the number a shadow run just recorded SIZED FROM THE
|
||||
BILLED QUARTER - i.e. from a measurement of what the battery itself did?
|
||||
|
||||
THE ONE PLACE THIS QUESTION IS ANSWERED, and it is public for the reason
|
||||
`peakguard.charge_headroom_w()`, `discharge_permitted()` and
|
||||
`freeze.looks_frozen()` are: the check that grades it has to assert on THE
|
||||
SHIPPED EXPRESSION. A predicate transcribed into its own test is one copy
|
||||
plus a future disagreement about what the check means.
|
||||
|
||||
------------------------------------------------------------------------
|
||||
THE DEFECT IT PREVENTS
|
||||
|
||||
`shadow.words()` and the action log carry "would have commanded N W". In
|
||||
SHADOW MODE the battery is held at `shadow.WIRE_W`, so the billed quarter
|
||||
the buy leg was sized against contains THE HOUSE AND NOTHING ELSE - while
|
||||
a live run's meter rises as the trade charges. The same code, the same
|
||||
hour, `peak_cap_w` 1500 under a 1200 W house: live commands -302.4 W and a
|
||||
shadow run records -2000.0 W. 6.61x, on the status row, with no caveat.
|
||||
This is the flag that puts the caveat there.
|
||||
|
||||
⚠️ IT IS TRUE WHENEVER A MEASURED HEADROOM ENTERED THE ARITHMETIC, NOT
|
||||
ONLY WHEN IT BOUND. `_act()` sizes the buy leg as `min(asked, headroom)`,
|
||||
and "the headroom did not bind" is ITSELF a measured fact about a quarter
|
||||
the battery never entered. Keying this on `capped` - on whether the
|
||||
shipped sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" - would answer
|
||||
True at the START of the quarter, where a shadow run and a live run still
|
||||
agree to the watt, and False at the END, where `(900/remaining)` has
|
||||
multiplied the headroom past the ask and the recorded number is at its
|
||||
most wrong. The quietest caveat exactly where it is needed loudest.
|
||||
|
||||
⚠️ THE BUY LEG ONLY. §9.1: "Discharge and export are never capped by the
|
||||
peak guard; only charging and import are." A sell is sized from
|
||||
`discharge_w`, which is the roster's own rating and not a measurement of
|
||||
the quarter, so a sell's recorded watts are NOT subject to this and must
|
||||
not carry a caveat that would then be false.
|
||||
|
||||
⚠️ AND THE ARBITER'S WINNER IS THE THIRD RUNG, NOT AN AFTERTHOUGHT. A trade
|
||||
that was sized from the meter and then OUT-RANKED is not the number being
|
||||
recorded - `Resolution.target_w` belongs to somebody else - and a caveat
|
||||
filed against somebody else's number is a false sentence on the status row,
|
||||
which is the defect class this whole card is about. It is in HERE and not
|
||||
in `main.py` for the reason the two rungs above are: all three answer one
|
||||
question, a check has to be able to reach each of them with the other two
|
||||
clear (TEST-16), and a rung that lives at a call site is a rung no check
|
||||
can drive.
|
||||
|
||||
`headroom_w` is whatever `peakguard.charge_headroom_w()` answered for the
|
||||
cycle this decision was taken on. ⚠️ None IS "NOTHING MEASURED IT", and
|
||||
`decide()` REFUSES the trade there (IDLE_HEADROOM_UNMEASURED), so a None
|
||||
can only ever arrive here beside a non-trading decision - but it is tested
|
||||
rather than assumed, because the caller is `main.py` and not this module.
|
||||
|
||||
`winner` is `Resolution.winner`: the source that actually set the watts.
|
||||
"""
|
||||
return (winner == SOURCE
|
||||
and decision is not None and decision.action == CHARGE
|
||||
and headroom_w is not None)
|
||||
|
||||
|
||||
def claim(decision: ArbitrageDecision) -> Claim | None:
|
||||
"""The decision as one arbiter claim, or None when nothing is to be traded.
|
||||
|
||||
|
||||
@@ -842,6 +842,18 @@ class Controller:
|
||||
# how a shadow run starts telling an operator a number nothing is
|
||||
# doing.
|
||||
self.shadow_would_w = None
|
||||
# SAFETY-47. Was the number above SIZED FROM THE BILLED-QUARTER METER
|
||||
# on the cycle it was recorded? ⚠️ IT IS RECORDED WHERE THE DECISION
|
||||
# WAS TAKEN, NOT RE-DERIVED WHERE THE PAGE IS RENDERED. The status page
|
||||
# runs on its own task and `self.peak_guard` has moved on by then, so a
|
||||
# page that asked the question again would be answering it about a
|
||||
# different cycle from the one whose watts it is displaying - which is
|
||||
# the same two-facts-one-field defect the comment above this one is
|
||||
# about. ⚠️ False AND NOT None BEFORE THE FIRST SHADOW CYCLE, unlike
|
||||
# the field above: this one is a claim ABOUT a number, and there is no
|
||||
# number yet, so the honest value is "nothing to disclose". The row's
|
||||
# `would_w is None` branch renders no watts at all there.
|
||||
self.shadow_sized_from_meter = False
|
||||
# Edge state for the action log, both of them. `_shadow_was` is None
|
||||
# until the first cycle, so an install that comes up IN shadow mode
|
||||
# says so in the log it will be read from rather than leaving the
|
||||
@@ -923,6 +935,12 @@ class Controller:
|
||||
# None (startup) or the PREVIOUS cycle's decision (an input hold), and
|
||||
# the status row rendered all three identically.
|
||||
self.arb_at = None
|
||||
# SAFETY-45/47. The billed-quarter charging headroom the arbitrage step
|
||||
# was handed on the cycle above, or None when nothing measured it. It
|
||||
# is CARRIED rather than recomputed for `arbitrage.sized_from_meter()`,
|
||||
# because `self.peak_guard` is a different cycle's decision by the time
|
||||
# the status page renders.
|
||||
self.arb_headroom_w = None
|
||||
# TARIFF-11. When the most recent cycle() STARTED. `arb_at < cycle_at`
|
||||
# is the exact, derived statement of "the latest cycle did not get as
|
||||
# far as the arbitrage step", which is the fact the *Arbitrage* row
|
||||
@@ -2818,9 +2836,16 @@ class Controller:
|
||||
# `arb_at` is then the age the status row reports rather than a
|
||||
# decision presented as current.
|
||||
self.arb, self.arb_at = None, now
|
||||
self.arb_headroom_w = None
|
||||
if arbitrage.enabled(self.o):
|
||||
floor_pct, ceiling_pct = arbitrage.soc_bounds(self.o)
|
||||
charge_w, discharge_w = self.trade_power_w(floor_pct, ceiling_pct)
|
||||
# SAFETY-47. HOISTED OUT OF THE CALL, NOT COPIED. One evaluation of
|
||||
# the shipped expression feeds both the sizing below and
|
||||
# `arbitrage.sized_from_meter()` in `_shadow_settle()`, so the
|
||||
# caveat on the recorded watts can never be answered from a
|
||||
# different cycle's guard than the watts were.
|
||||
self.arb_headroom_w = peakguard.charge_headroom_w(self.peak_guard)
|
||||
self.arb = arbitrage.decide(
|
||||
self.fresh_tariff_plan(now), now,
|
||||
peak_guard_active=arbitrage.guard_state(self.peak_guard),
|
||||
@@ -2839,7 +2864,7 @@ class Controller:
|
||||
# peak block's conclusion, ~50 lines up, so it must stay after
|
||||
# it. Evaluated earlier it would size this quarter's trade from
|
||||
# the previous cycle's quarter.
|
||||
charge_headroom_w=peakguard.charge_headroom_w(self.peak_guard),
|
||||
charge_headroom_w=self.arb_headroom_w,
|
||||
# The emptiest pack again, and for the sell side that is the
|
||||
# right reduction. ⚠️ THE BUY SIDE WANTS THE FULLEST, and there
|
||||
# is one `soc` argument - `pack_floor_soc` names that residual
|
||||
@@ -3424,20 +3449,37 @@ class Controller:
|
||||
"%+.0f W that was standing on the wire.", shadow.WIRE_W)
|
||||
if not engaged:
|
||||
self.shadow_would_w = None
|
||||
self.shadow_sized_from_meter = False
|
||||
self._shadow_winner = None
|
||||
return
|
||||
self.shadow_would_w = float(resolution.target_w)
|
||||
# SAFETY-47. ⚠️ NO LOGIC HERE, DELIBERATELY. All three rungs - the
|
||||
# arbiter's winner, the leg being a CHARGE, and the headroom having
|
||||
# been MEASURED - live inside `arbitrage.sized_from_meter()`, which
|
||||
# says why, including why it is NOT keyed on whether the trade was
|
||||
# capped. A rung written at a call site is a rung no check can reach
|
||||
# with the other two clear, which is TEST-16's rule.
|
||||
self.shadow_sized_from_meter = arbitrage.sized_from_meter(
|
||||
self.arb, self.arb_headroom_w, winner=resolution.winner)
|
||||
# ⚠️ THE WINNER AND THE ROUNDED WATTS, NOT THE WATTS ALONE. A decision
|
||||
# that moves from the loop to the peak guard at the same number is a
|
||||
# different decision and the operator needs the line; a loop target
|
||||
# that wanders by a watt is not, and 15 s of those would be the whole
|
||||
# log.
|
||||
edge = (resolution.winner, round(float(resolution.target_w)))
|
||||
# ⚠️ SAFETY-47 ADDS THE CAVEAT FLAG TO THE EDGE. The same winner at the
|
||||
# same watts with and without the caveat are two different claims about
|
||||
# the same number, and an edge key blind to that would print the first
|
||||
# one and silently keep it standing. It cannot flood: the flag only
|
||||
# moves when arbitrage starts or stops owning the resolution, or when
|
||||
# the guard starts or stops measuring the quarter, and both of those
|
||||
# move the winner or the watts as well on every cycle measured.
|
||||
edge = (resolution.winner, round(float(resolution.target_w)),
|
||||
self.shadow_sized_from_meter)
|
||||
if edge != self._shadow_winner:
|
||||
self._shadow_winner = edge
|
||||
self.log_event(
|
||||
f"SHADOW: would have commanded {resolution.target_w:+.0f} W - "
|
||||
+ resolution.explain())
|
||||
self.log_event(shadow.log_line(
|
||||
would_w=resolution.target_w, reason=resolution.explain(),
|
||||
sized_from_meter=self.shadow_sized_from_meter))
|
||||
self.target = shadow.WIRE_W
|
||||
for inv in self.inverters:
|
||||
inv.target = shadow.WIRE_W
|
||||
@@ -4865,7 +4907,12 @@ class Controller:
|
||||
# learn something is a surface you have to already know about.
|
||||
("Shadow mode", shadow.words(
|
||||
self.o, control_started=self.auto,
|
||||
would_w=self.shadow_would_w, reason=self.reason)),
|
||||
would_w=self.shadow_would_w,
|
||||
# SAFETY-47. THE FLAG THE CYCLE RECORDED, NOT ONE DERIVED HERE
|
||||
# - the page runs on its own task and `self.peak_guard` has
|
||||
# moved on. See `Controller.__init__`.
|
||||
sized_from_meter=self.shadow_sized_from_meter,
|
||||
reason=self.reason)),
|
||||
("Why", self.reason),
|
||||
("Maintenance phase", self.maint.phase if len(self.inverters) <= 1
|
||||
else f"{self.maint.phase} ({self.maint_unit.name})"),
|
||||
|
||||
+169
-12
@@ -19,6 +19,83 @@ learn nothing. Shadow mode is the third option: strategies, arbiter, clamps and
|
||||
guards all run, the decision is recorded with its reason, and NOTHING THE
|
||||
CONTROLLER DECIDES REACHES THE INVERTER.
|
||||
|
||||
⚠️ AND OF THOSE THREE, A SHADOW RUN CAN SHOW YOU EXACTLY ONE - SEE THE NEXT
|
||||
SECTION. This header used to name SAFETY-45's limit cycle as the example
|
||||
of what shadow mode surfaces. That was false, and SAFETY-47 measured it.
|
||||
|
||||
⚠️ WHAT A SHADOW RUN CAN AND CANNOT SHOW (SAFETY-47)
|
||||
=====================================================
|
||||
SHADOW MODE CANNOT SURFACE A CLOSED-LOOP DEFECT. Not badly, not partially -
|
||||
NOT AT ALL, and by the same construction that makes it safe. The actuator is
|
||||
held at WIRE_W and the carried command is re-seeded to WIRE_W, so every
|
||||
MEASURED input - the meter, the quarter accumulator behind it, the battery
|
||||
power, the state of charge - describes a plant that DID NOT RESPOND. A
|
||||
closed-loop defect is by definition one whose stimulus is the plant's response
|
||||
to the controller. No response, no stimulus, no defect to see.
|
||||
|
||||
That is not a gap to be closed later. Feeding the guards a simulated plant
|
||||
instead is what SAFETY-10 §4 refuses for the sign watchdogs, for a reason that
|
||||
applies to all of this: a controller reacting to a plant that does not exist
|
||||
drifts further from reality every tick, and three cycles in its numbers
|
||||
describe nothing. THE CLOSED-LOOP ANSWER COMES FROM A CLOSED-LOOP RIG
|
||||
(TEST-23 stage 3) OR FROM A LIVE RUN. There is no third place.
|
||||
|
||||
So, of the three defects above, measured on that rig at `peak_cap_w` 1500 /
|
||||
house 1200 / `max_w` 2000, one hour at a 5 s cycle:
|
||||
|
||||
* SAFETY-45's limit cycle NOT VISIBLE. Live: 28 charge onsets, the grid
|
||||
swinging -455.5 .. +3200.0 W, the guard engaged
|
||||
on 410 of 720 cycles. Shadow, same hour, same
|
||||
code: 1 onset, the grid flat at the 1200 W
|
||||
house, the guard engaged on 0 of 720. Every
|
||||
term of `wanted = batt_w + excess` is measured.
|
||||
* SAFETY-46's SoC churn NOT VISIBLE. The SoC moves 0.000000000 pp in a
|
||||
shadow run, because it is the pack's integral of
|
||||
what the pack was commanded and the pack was
|
||||
commanded 0 W. No SoC limit can be REACHED in a
|
||||
shadow run; the ones already crossed when it
|
||||
started are reported, and that is all.
|
||||
* TARIFF-14's wrong quarter VISIBLE, and it is the one. The price lookup's
|
||||
inputs are the CLOCK and the PRICE SERIES, and
|
||||
neither is a function of what the battery did.
|
||||
Measured: which hour the strategy picked, its
|
||||
price and the spread it cleared are identical
|
||||
live and shadow on 720 of 720 charging cycles,
|
||||
AT A BINDING CAP.
|
||||
|
||||
⚠️ THE EXEMPTION THAT USED TO BE HERE WAS TRUE UNTIL SAFETY-45 MERGED. This
|
||||
module, DOCS.md and DECISIONS/SAFETY-10-shadow-mode.md all said "the strategies
|
||||
are unaffected - they ask for a fixed power from inputs that do not depend on
|
||||
what the battery did". SAFETY-45 made the buy leg `min(asked, headroom)` with
|
||||
|
||||
headroom = (900 / remaining) x (ceiling - projected)
|
||||
|
||||
and `projected` reads the OPEN QUARTER'S ACCUMULATOR - the meter - which is a
|
||||
function of what the battery did earlier in that same quarter. The strategy
|
||||
became closed-loop the day that landed. What survives of the exemption, and
|
||||
only this:
|
||||
|
||||
WHICH hour a strategy picks, and WHY, are unaffected.
|
||||
HOW HARD it trades is not.
|
||||
|
||||
⚠️ AND THE SIZE A SHADOW RUN RECORDS IS THE RIGHT ANSWER TO A QUESTION NOBODY
|
||||
ASKED. `900/remaining` is correct arithmetic for a meter that is genuinely
|
||||
under the ceiling - and in shadow the meter genuinely IS under it, because the
|
||||
battery is not charging. So the number is not a bug; it is an answer computed
|
||||
for a plant that did not exist. Measured on the same rig, shipped code:
|
||||
|
||||
cap / house live commanded shadow recorded over
|
||||
1500 / 1200 -302.4 W -2000.0 W 6.61x
|
||||
3500 / 3000 -502.6 W -2000.0 W 3.98x
|
||||
3500 / 2000 -1502.6 W -2000.0 W 1.33x
|
||||
3500 / 1800 -1702.6 W -2000.0 W 1.17x
|
||||
15000 / 350 -2000.0 W -2000.0 W 1.00x
|
||||
|
||||
The last row is the fixture SAFETY-10's own evidence was taken on, which is why
|
||||
nothing reported this. `words()` carries the caveat rather than a re-computed
|
||||
number, and `DECISIONS/SAFETY-47-what-a-shadow-run-can-show.md` §3 records the
|
||||
three alternatives that were rejected and why.
|
||||
|
||||
⚠️ "REACHES NOTHING" IS NOT "WRITES NOTHING", AND THE DIFFERENCE IS THE WHOLE
|
||||
SAFETY ARGUMENT
|
||||
=======================================================================
|
||||
@@ -138,11 +215,18 @@ THE FAILSAFES, ONE BY ONE (the card asks for each to be decided and recorded)
|
||||
| | resolved intent against a meter that has |
|
||||
| | stopped moving, and both halves are as |
|
||||
| | true in shadow as out of it. |
|
||||
| SAFETY-07/24/25 peak guard | OBSERVES. Level-triggered, unlatched, and |
|
||||
| | it files its claim as usual so the |
|
||||
| | recorded decision is the real one. |
|
||||
| | SAFETY-45's limit cycle is visible from a |
|
||||
| | shadow run; that is the point. |
|
||||
| SAFETY-07/24/25 peak guard | OBSERVES, AND SEES ONLY THE HOUSE. It is |
|
||||
| | level-triggered and unlatched and it files|
|
||||
| | its claim as usual, so the recorded |
|
||||
| | decision is the real one FOR THIS METER - |
|
||||
| | but every term of `wanted = batt_w + |
|
||||
| | excess` is measured, and in shadow mode |
|
||||
| | the battery contributes nothing to either.|
|
||||
| | ⚠️ SAFETY-47: this row used to claim |
|
||||
| | SAFETY-45's limit cycle was visible from a|
|
||||
| | shadow run. It is not - 410/720 engaged |
|
||||
| | cycles live against 0/720 in shadow, on |
|
||||
| | the same hour and the same code. |
|
||||
| SAFETY-31 circulation | OBSERVES AND MAY LATCH, legitimately. Its |
|
||||
| SAFETY-42 delivery | evidence is MEASURED power, not a |
|
||||
| | command: packs pushing against each other |
|
||||
@@ -215,6 +299,29 @@ MODES = ("auto", "on", "off")
|
||||
#: commanding it so the inverter cannot be left latched on anything else.
|
||||
WIRE_W = 0.0
|
||||
|
||||
#: SAFETY-47. What the recorded watts mean when a MEASURED billed quarter sized
|
||||
#: them.
|
||||
#:
|
||||
#: ⚠️ "UPPER BOUND" AND NOT "SMALLER", AND THE DIFFERENCE WAS MEASURED RATHER
|
||||
#: THAN ARGUED. Charging only ADDS offtake, so a live meter's `projected` is
|
||||
#: never below a shadow meter's and the headroom is never above it: the shadow
|
||||
#: size is >= the live size, with EQUALITY at the start of every quarter, where
|
||||
#: `900/remaining` is 1.0 and neither plant has moved. Measured pairwise over
|
||||
#: 3600 charging cycles in five configurations - 0 cycles below, 730 exactly
|
||||
#: equal. A sentence reading "smaller" would have been false on every one of
|
||||
#: those 730.
|
||||
#:
|
||||
#: ⚠️ AND IT NAMES NO FACTOR. How far under the bound a live run lands is a
|
||||
#: property of the site - 6.61x at a 1500 W cap under a 1200 W house, 1.00x at
|
||||
#: a cap that does not bind - and a number invented for the row would be a
|
||||
#: second helping of the defect this constant exists to disclose.
|
||||
SIZED_FROM_METER = (
|
||||
"⚠️ AND ITS SIZE CAME FROM THE BILLED-QUARTER METER, WHICH HAS ONLY THE "
|
||||
"HOUSE IN IT WHILE THE BATTERY IS HELD AT 0 W. A live run sizes the same "
|
||||
"trade against a meter the battery is moving, so this is an UPPER BOUND "
|
||||
"and not a prediction; how far under it a live run lands is a closed-loop "
|
||||
"question and a shadow run cannot answer it")
|
||||
|
||||
|
||||
def mode(opts: dict) -> str:
|
||||
"""The configured `shadow_mode`, normalised to one of `MODES`.
|
||||
@@ -279,7 +386,7 @@ def why(opts: dict, *, control_started: bool) -> str:
|
||||
|
||||
|
||||
def words(opts: dict, *, control_started: bool, would_w: float | None,
|
||||
reason: str = "") -> str:
|
||||
sized_from_meter: bool, reason: str = "") -> str:
|
||||
"""The status page's `Shadow mode` row.
|
||||
|
||||
⚠️ THE ROW IS RENDERED IN EVERY STATE, INCLUDING `off`. A surface whose
|
||||
@@ -288,10 +395,35 @@ def words(opts: dict, *, control_started: bool, would_w: float | None,
|
||||
what gets graded, so there has to be text in both states.
|
||||
|
||||
`would_w` is the decision the path reached this cycle - what a live
|
||||
controller would have put on the wire - and `reason` is
|
||||
`Resolution.explain()`, the same sentence the `Why` row carries. Together
|
||||
they are the whole of "what would it have done, and why"; without them the
|
||||
row would say a shadow run happened and nothing about what it found.
|
||||
controller would have put on the wire GIVEN THIS METER AND A BATTERY AT
|
||||
0 W - and `reason` is `Resolution.explain()`, the same sentence the `Why`
|
||||
row carries. Together they are the whole of "what would it have done, and
|
||||
why"; without them the row would say a shadow run happened and nothing
|
||||
about what it found.
|
||||
|
||||
⚠️ `sized_from_meter` HAS NO DEFAULT, AND THAT IS SAFETY-47's WHOLE POINT.
|
||||
It is True when a MEASURED billed-quarter headroom sized the number being
|
||||
recorded - `arbitrage.sized_from_meter()` answers it, and it is the one
|
||||
place the question is asked. A default of False here would be a caller
|
||||
that forgot the caveat rendering a row that reads exactly like a caller
|
||||
that decided it did not apply, which is the shape of defect this card is
|
||||
about. TEST-14's rule with a new name on it.
|
||||
|
||||
⚠️ AND THE PHRASE IS "ON THIS CYCLE", UNCONDITIONALLY, NOT ONLY WHEN THE
|
||||
CAVEAT FIRES. Every number a shadow run records was reached from a plant
|
||||
that did not respond; "WOULD HAVE COMMANDED -2 000 W" reads as a forecast
|
||||
of a live run and no number here is one. The ⚠️ below is the STRONGER,
|
||||
conditional statement about the cycles where the answer can be multiples
|
||||
out - see this module's header for the measured table.
|
||||
|
||||
⚠️ AND IT IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED. `arbitrage`'s own
|
||||
sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" only when the headroom
|
||||
came out BELOW the ask - which in a shadow run is the START of the
|
||||
quarter, where the two runs still agree. By the end of the quarter
|
||||
`900/remaining` has multiplied the headroom past the ask, the trade is
|
||||
NOT capped, the sentence is silent and the recorded number is at its most
|
||||
wrong. A caveat keyed on that sentence would be quietest exactly where it
|
||||
is needed loudest. `test_arbitrage.py` part 3d-8 drives that.
|
||||
"""
|
||||
head = why(opts, control_started=control_started)
|
||||
if not engaged(opts, control_started=control_started):
|
||||
@@ -304,13 +436,38 @@ def words(opts: dict, *, control_started: bool, would_w: float | None,
|
||||
# half that says WHICH RUNG decided, which is the claim MUTATION.md's
|
||||
# masking rule says must survive.
|
||||
num = f"{float(would_w):+,.0f}".replace(",", " ")
|
||||
out = (f"{head}; WOULD HAVE COMMANDED {num} W, inverter held at "
|
||||
f"{WIRE_W:.0f} W")
|
||||
out = (f"{head}; ON THIS CYCLE WOULD HAVE COMMANDED {num} W, inverter "
|
||||
f"held at {WIRE_W:.0f} W")
|
||||
if sized_from_meter:
|
||||
out += f" {SIZED_FROM_METER}"
|
||||
if reason:
|
||||
out += f" - {reason}"
|
||||
return out
|
||||
|
||||
|
||||
def log_line(*, would_w: float, reason: str, sized_from_meter: bool) -> str:
|
||||
"""The action-log line for one change of shadow decision.
|
||||
|
||||
⚠️ IT IS A FUNCTION FOR THE REASON `words()` IS ONE, AND SAFETY-47 LEARNED
|
||||
IT THE EXPENSIVE WAY. This sentence used to be an f-string inside
|
||||
`Controller._shadow_settle()`. Deleting the caveat from it there left all
|
||||
29 files GREEN - the only check that could see the line drove a fixture
|
||||
with `meter_source: off`, where no arbitrage decision and therefore no
|
||||
caveat can ever be reached. A sentence assembled at a call site is a
|
||||
sentence no check can grade, and the page would have said one thing while
|
||||
the record a later analysis reads said another.
|
||||
|
||||
⚠️ AND IT IS THE SAME `SIZED_FROM_METER` CONSTANT THE ROW CARRIES, not a
|
||||
second wording of it. Two sentences meaning one thing is how the two
|
||||
surfaces start disagreeing about which cycles are caveated.
|
||||
"""
|
||||
out = (f"SHADOW: would have commanded {float(would_w):+.0f} W ON THIS "
|
||||
f"CYCLE - {reason}")
|
||||
if sized_from_meter:
|
||||
out += f" {SIZED_FROM_METER}"
|
||||
return out
|
||||
|
||||
|
||||
def banner(opts: dict, *, control_started: bool, latched: tuple = ()) -> tuple:
|
||||
"""`(level, text)` for the top of the status page, or `None` when live.
|
||||
|
||||
|
||||
@@ -94,6 +94,8 @@ from app.arbitrage import (
|
||||
CHARGE, DISCHARGE, ArbitrageDecision, claim, decide, enabled, soc_bounds,
|
||||
threshold_eur_kwh,
|
||||
)
|
||||
# SAFETY-47 section 3d. The shipped shadow-mode row, not a transcription of it.
|
||||
from app import shadow as _shadow
|
||||
from app.price import (
|
||||
PRICE_OPTION_DEFAULTS, Absence, PricePoint, PriceProduct, PriceRead,
|
||||
Uncertainty, WIDEN_FACTOR, brussels, required_spread, widen_factor,
|
||||
@@ -890,18 +892,61 @@ check("a ZERO headroom does not cap a DISCHARGE. §9.1: 'discharge and export "
|
||||
# caller fills is a TypeError only on the one path a suite does not run. Same
|
||||
# pin, same reason, as `weights=` in test_packshare.py part 10.
|
||||
_S45_MAIN = open(os.path.join(HERE, "app", "main.py"), encoding="utf-8").read()
|
||||
_s45_calls = [n for n in ast.walk(ast.parse(_S45_MAIN))
|
||||
_S45_MAIN_TREE = ast.parse(_S45_MAIN)
|
||||
_s45_calls = [n for n in ast.walk(_S45_MAIN_TREE)
|
||||
if isinstance(n, ast.Call)
|
||||
and ast.unparse(n.func).endswith("arbitrage.decide")]
|
||||
_s45_arg = [ast.unparse(k.value) for c in _s45_calls for k in c.keywords
|
||||
if k.arg == "charge_headroom_w"]
|
||||
|
||||
|
||||
def _s45_assigned(name, clear=("None",)):
|
||||
"""Every expression main.py assigns to `self.<name>` that is not a CLEAR.
|
||||
|
||||
⚠️ SAFETY-47 HOISTED THE HEADROOM OUT OF THE CALL, so pinning the call
|
||||
argument alone stopped covering anything: the literal a mutation would put
|
||||
there now goes one line up instead. Both ends are pinned.
|
||||
|
||||
⚠️ `clear` NAMES THE CONSTANTS THAT MEAN "NOTHING HAS ANSWERED THIS YET" -
|
||||
`__init__`'s value and the per-cycle reset - and they are not a second
|
||||
source for the number. Excluding them does NOT soften the pin: a mutation
|
||||
that replaces the real assignment with one of those constants leaves this
|
||||
list EMPTY, which matches no expected value and is red.
|
||||
"""
|
||||
return [ast.unparse(n.value) for n in ast.walk(_S45_MAIN_TREE)
|
||||
if isinstance(n, ast.Assign)
|
||||
and [ast.unparse(t) for t in n.targets] == [f"self.{name}"]
|
||||
and ast.unparse(n.value) not in clear]
|
||||
|
||||
|
||||
_s45_head_src = _s45_assigned("arb_headroom_w")
|
||||
print(f" main.py has {len(_s45_calls)} `arbitrage.decide(` call site(s); "
|
||||
f"charge_headroom_w= is {_s45_arg}")
|
||||
f"charge_headroom_w= is {_s45_arg}, and self.arb_headroom_w is assigned "
|
||||
f"from {_s45_head_src}")
|
||||
check("main.py passes the guard's OWN measured headroom at its one "
|
||||
"arbitrage.decide() call site - the shipped expression, not a "
|
||||
"transcription of it, so a mutation back to a literal or to max_w is red "
|
||||
"rather than silent",
|
||||
_s45_arg == ["peakguard.charge_headroom_w(self.peak_guard)"])
|
||||
_s45_arg == ["self.arb_headroom_w"]
|
||||
and _s45_head_src == ["peakguard.charge_headroom_w(self.peak_guard)"])
|
||||
# ⚠️ AND THE HOIST DID NOT MOVE IT OUT OF THE CYCLE. An `arb_headroom_w` set
|
||||
# once in `__init__` and never refreshed would satisfy the pin above and would
|
||||
# size every trade from the guard decision of whatever cycle happened to run
|
||||
# last - which is the defect the hoist's own comment warns about, one level up.
|
||||
_s45_cycle = next(n for n in ast.walk(_S45_MAIN_TREE)
|
||||
if isinstance(n, (ast.FunctionDef, ast.AsyncFunctionDef))
|
||||
and n.name == "cycle"
|
||||
and any(isinstance(c, ast.Call)
|
||||
and ast.unparse(c.func).endswith("arbitrage.decide")
|
||||
for c in ast.walk(n)))
|
||||
check("...and the assignment is INSIDE the same `cycle()` that makes the call, "
|
||||
"so the headroom the trade is sized from is this cycle's guard decision "
|
||||
"and not one carried from an arbitrary earlier one",
|
||||
any(isinstance(n, ast.Assign)
|
||||
and [ast.unparse(t) for t in n.targets] == ["self.arb_headroom_w"]
|
||||
and ast.unparse(n.value)
|
||||
== "peakguard.charge_headroom_w(self.peak_guard)"
|
||||
for n in ast.walk(_s45_cycle)))
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
@@ -946,14 +991,26 @@ S45_T0 = D0 + timedelta(hours=CHEAP_H)
|
||||
|
||||
|
||||
def s45_loop(*, sized: bool, cap_w=S45_CAP_W, load_w=S45_LOAD_W,
|
||||
seconds=S45_RUN_S):
|
||||
seconds=S45_RUN_S, shadow=False):
|
||||
"""One closed hour. `sized=False` is the behaviour this card removes.
|
||||
|
||||
⚠️ THE COUNTERFACTUAL IS ONE ARGUMENT, NOT A SECOND CODE PATH. `sized=False`
|
||||
hands `decide()` a headroom nothing can bind - which is exactly what the
|
||||
tree did before this card, because nothing was passing one - so the two runs
|
||||
below differ in one value and share every line of shipped code. Habit 7.
|
||||
|
||||
⚠️ SAFETY-47's `shadow=True` IS THE SAME DISCIPLINE, ONE ARGUMENT AGAIN. It
|
||||
reproduces the THREE things `Controller._write_unit()` and
|
||||
`_shadow_settle()` do and nothing else: the resolved command is RECORDED,
|
||||
the plant is driven from `shadow.WIRE_W` instead of from it, and the
|
||||
carried command is RE-SEEDED to `shadow.WIRE_W` after the record is taken.
|
||||
Those three lines are a TRANSCRIPTION of main.py's placement and are marked
|
||||
as one - `test_clamp.py` part 8 is the check on the shipped placement, and
|
||||
it drives the real `Controller`. What is NOT transcribed is every number
|
||||
that matters here: the averager, the projection, the guard, the headroom,
|
||||
the strategy, the arbiter and the row's own words are all the shipped ones.
|
||||
"""
|
||||
|
||||
avg = QuarterAverager(phases=1, max_hold_s=900.0)
|
||||
tuning = Tuning(gain=0.6, max_w=MAX_W, slew_w=0.0)
|
||||
t0 = S45_T0
|
||||
@@ -962,6 +1019,7 @@ def s45_loop(*, sized: bool, cap_w=S45_CAP_W, load_w=S45_LOAD_W,
|
||||
loop_w = None
|
||||
batt_cmd = batt = 0.0 # + discharge, as main.py's site_batt_w
|
||||
onsets = blocks = 0
|
||||
rec = []
|
||||
prev_action = "<start>"
|
||||
grid_lo, grid_hi = None, None
|
||||
billed = []
|
||||
@@ -1008,7 +1066,32 @@ def s45_loop(*, sized: bool, cap_w=S45_CAP_W, load_w=S45_LOAD_W,
|
||||
claims.append(Claim.limit("supervised", P_SAFETY, -MAX_W, MAX_W,
|
||||
"max_w"))
|
||||
claims.append(Claim.set("loop", P_LOOP, d.target_w, d.reason))
|
||||
target = resolve(claims).target_w
|
||||
res = resolve(claims)
|
||||
target = res.target_w
|
||||
head_w = _pg.charge_headroom_w(pk) if sized else HEADROOM_CLEAR
|
||||
rec.append(dict(
|
||||
t_s=t, action=arb.action, power_w=arb.power_w,
|
||||
reason=arb.reason, price=arb.price_now_eur_kwh,
|
||||
spread=arb.spread_eur_kwh, winner=res.winner,
|
||||
target_w=float(res.target_w), headroom_w=head_w,
|
||||
engaged=bool(pk.engaged),
|
||||
sized_from_meter=_arb.sized_from_meter(
|
||||
arb, head_w, winner=res.winner)))
|
||||
if shadow:
|
||||
# --- TRANSCRIBED 1/3: `_shadow_settle()`'s record, taken
|
||||
# BEFORE the re-seed destroys its evidence.
|
||||
rec[-1]["would_w"] = float(res.target_w)
|
||||
rec[-1]["row"] = _shadow.words(
|
||||
{"shadow_mode": "on"}, control_started=False,
|
||||
would_w=float(res.target_w),
|
||||
sized_from_meter=rec[-1]["sized_from_meter"],
|
||||
reason=res.explain())
|
||||
# --- TRANSCRIBED 2/3: `_write_unit()`'s substitution - the
|
||||
# plant below is driven from WIRE_W, not from the decision.
|
||||
# --- TRANSCRIBED 3/3: `_shadow_settle()`'s re-seed of the
|
||||
# carried command, which is what `compute(prev_w=...)`,
|
||||
# `standing_w()` and SAFETY-42 read next cycle.
|
||||
target = _shadow.WIRE_W
|
||||
# THE PLANT, MODELLED: an 800 W/s ramp into a 10 s first-order lag.
|
||||
step = min(1.0, acc)
|
||||
delta = target - batt_cmd
|
||||
@@ -1020,7 +1103,9 @@ def s45_loop(*, sized: bool, cap_w=S45_CAP_W, load_w=S45_LOAD_W,
|
||||
grid_hi = grid if grid_hi is None else max(grid_hi, grid)
|
||||
return dict(onsets=onsets, grid_lo=round(grid_lo, 1),
|
||||
grid_hi=round(grid_hi, 1), swing=round(grid_hi - grid_lo, 1),
|
||||
billed=billed, blocks=blocks)
|
||||
billed=billed, blocks=blocks, rec=rec,
|
||||
engaged=sum(1 for r in rec if r["engaged"]),
|
||||
cycles=len(rec))
|
||||
|
||||
S45_BEFORE = derived(lambda: s45_loop(sized=False))
|
||||
S45_AFTER = derived(lambda: s45_loop(sized=True))
|
||||
@@ -1076,11 +1161,440 @@ S45_WIDE_S = derived(lambda: s45_loop(sized=True, cap_w=5000.0, load_w=1200.0,
|
||||
print(f" peak_cap_w 5000 W, 1200 W house (load + max_w = "
|
||||
f"{S45_LOAD_W + MAX_W:.0f} W, under the cap): unsized "
|
||||
f"{S45_WIDE['billed']} W, sized {S45_WIDE_S['billed']} W")
|
||||
|
||||
|
||||
|
||||
def _s45_outcome(r):
|
||||
"""Everything the two runs put on the PLANT and the METER.
|
||||
|
||||
⚠️ `rec` IS EXCLUDED AND THE EXCLUSION IS NAMED. SAFETY-47 added a
|
||||
per-cycle record to this harness, and it carries `headroom_w` and
|
||||
`sized_from_meter` - which are THE ONE ARGUMENT the two runs differ in, by
|
||||
construction. Comparing them would make this check fail for the reason it
|
||||
exists to rule out. The resolved command per cycle IS compared, below, and
|
||||
that is a stronger statement than the six aggregates ever were.
|
||||
"""
|
||||
return {k: v for k, v in r.items() if k != "rec"}
|
||||
|
||||
|
||||
check("on a site where the trade cannot reach the cap the two runs are "
|
||||
"IDENTICAL to the watt - so this card costs nothing on the installs it "
|
||||
"is not about, and the check above is not passing because the cap "
|
||||
"dominates everything",
|
||||
S45_WIDE == S45_WIDE_S and S45_WIDE["onsets"] == 1)
|
||||
_s45_outcome(S45_WIDE) == _s45_outcome(S45_WIDE_S)
|
||||
and S45_WIDE["onsets"] == 1)
|
||||
check("...and identical CYCLE BY CYCLE, not merely in the six aggregates: "
|
||||
"every resolved command and every traded size matches to the float",
|
||||
[(r["target_w"], r["power_w"]) for r in S45_WIDE["rec"]]
|
||||
== [(r["target_w"], r["power_w"]) for r in S45_WIDE_S["rec"]])
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print()
|
||||
print("3d. SAFETY-47 - the SHADOW record against a LIVE run, at a BINDING cap")
|
||||
# ---------------------------------------------------------------------------
|
||||
# WHAT THIS PART EXISTS FOR, AND IT IS NOT A SECOND SAFETY-45 CHECK.
|
||||
#
|
||||
# SAFETY-10 shipped shadow mode saying, in three merged documents, that "the
|
||||
# strategies are unaffected - they ask for a fixed power from inputs that do
|
||||
# not depend on what the battery did - so a shadow run does show you the
|
||||
# trades, the peak-guard engagements and the SoC-limit behaviour". That was
|
||||
# true until 3c's own fix merged. SAFETY-45 makes the buy leg
|
||||
# `min(asked, headroom)`, and the headroom is
|
||||
#
|
||||
# (900 / remaining) x (ceiling - projected)
|
||||
#
|
||||
# where `projected` reads the OPEN QUARTER'S ACCUMULATOR - the meter - which is
|
||||
# a function of what the battery did earlier in that same quarter. The strategy
|
||||
# became closed-loop the day 3c landed, and shadow mode holds the battery at
|
||||
# 0 W, so in a shadow run that accumulator contains THE HOUSE AND NOTHING ELSE.
|
||||
#
|
||||
# ⚠️ AND SAFETY-10 §6's COMMITTED EVIDENCE COULD NEVER HAVE FAILED - TWO
|
||||
# INDEPENDENT REASONS, AND CLOSING EITHER ONE ALONE CLOSES NOTHING.
|
||||
# (1) its fixture is `peak_cap_w: 15000` against a 350 W house, so the guard
|
||||
# never engages and the sizing is inert - MUTATION.md habit 4, inside a
|
||||
# merged card's own proof;
|
||||
# (2) every identity row reads THE FIRST CHARGING SAMPLE, and at `elapsed=0`
|
||||
# the projection IS the held level, so the two runs agree to the float
|
||||
# there even AT a binding cap. 3d-2 drives that and says so.
|
||||
#
|
||||
# So this part is the grader for the class: a shadow run and a live run, the
|
||||
# same hour, the same code, at a cap that BINDS. What is REAL and what is
|
||||
# TRANSCRIBED is in `s45_loop()`'s own docstring - the three lines that stand
|
||||
# in for `Controller._write_unit()` and `_shadow_settle()` are named there, and
|
||||
# `test_clamp.py` part 8 is the check on the shipped placement.
|
||||
# ---------------------------------------------------------------------------
|
||||
S47_LIVE = derived(lambda: s45_loop(sized=True))
|
||||
S47_SHAD = derived(lambda: s45_loop(sized=True, shadow=True))
|
||||
# The SAFETY-45 defect itself, watched from inside shadow mode - which is what
|
||||
# SAFETY-10's header claimed a shadow run would surface.
|
||||
S47_UNSIZED_SHAD = derived(lambda: s45_loop(sized=False, shadow=True))
|
||||
|
||||
_s47_lc = derived(lambda: [r for r in S47_LIVE["rec"] if r["action"] == CHARGE])
|
||||
_s47_sc = derived(lambda: [r for r in S47_SHAD["rec"] if r["action"] == CHARGE])
|
||||
|
||||
# ⚠️ THE SECTION CARRIES ITS OWN PRECONDITION INTO EVERY CHECK, AND THIS IS
|
||||
# FCST-06's SHAPE RATHER THAN TIDINESS. A mutation that stops either run
|
||||
# trading at all leaves these lists EMPTY; the first `min()` below then raises,
|
||||
# the file dies before part 4, and the run reports ZERO reds - which reads
|
||||
# exactly like a survivor. Measured: driving `wanted = batt_w - ex` through
|
||||
# this section did precisely that. So the lists are replaced by a sentinel that
|
||||
# cannot satisfy anything, and `s47check()` fails every check in the section
|
||||
# when the stimulus was not produced.
|
||||
_S47_DEAD = dict(action=None, power_w=0.0, reason="<no charging cycle>",
|
||||
price=None, spread=None, winner=None, target_w=0.0,
|
||||
headroom_w=0.0, engaged=False, sized_from_meter=False,
|
||||
would_w=0.0, row="", t_s=0.0)
|
||||
_S47_OK = bool(_s47_lc) and bool(_s47_sc)
|
||||
if not _S47_OK:
|
||||
_s47_lc = _s47_sc = [dict(_S47_DEAD)]
|
||||
_s47_n = min(len(_s47_lc), len(_s47_sc))
|
||||
|
||||
|
||||
def s47check(name, cond):
|
||||
"""A 3d check, AND the section's own precondition, in one verdict."""
|
||||
check(name, _S47_OK and bool(cond))
|
||||
|
||||
|
||||
check("PRECONDITION: both runs actually reached a charging decision - without "
|
||||
"this the section raises on its first `min()`, the file dies before "
|
||||
"part 4 and the run reports ZERO reds, which reads exactly like a "
|
||||
"survivor (MUTATION.md, FCST-06's shape). Measured, not imagined",
|
||||
_S47_OK)
|
||||
print(f" live : {len(_s47_lc)} charging cycles, traded "
|
||||
f"{min(r['power_w'] for r in _s47_lc):+.1f} .. "
|
||||
f"{max(r['power_w'] for r in _s47_lc):+.1f} W, "
|
||||
f"headroom {min(r['headroom_w'] for r in _s47_lc):.1f} .. "
|
||||
f"{max(r['headroom_w'] for r in _s47_lc):.1f} W, "
|
||||
f"grid {S47_LIVE['grid_lo']:.0f} .. {S47_LIVE['grid_hi']:.0f} W")
|
||||
print(f" shadow: {len(_s47_sc)} charging cycles, RECORDED "
|
||||
f"{min(r['power_w'] for r in _s47_sc):+.1f} .. "
|
||||
f"{max(r['power_w'] for r in _s47_sc):+.1f} W, "
|
||||
f"headroom {min(r['headroom_w'] for r in _s47_sc):.1f} .. "
|
||||
f"{max(r['headroom_w'] for r in _s47_sc):.1f} W, "
|
||||
f"grid {S47_SHAD['grid_lo']:.0f} .. {S47_SHAD['grid_hi']:.0f} W")
|
||||
|
||||
# --- 3d-1. THE PRECONDITION: the cap binds, and the meter proves it --------
|
||||
# ⚠️ WITHOUT THIS EVERY CHECK BELOW IS SAFETY-10 §6's DEFECT IN A NEW FILE. At
|
||||
# a cap the trade cannot reach, live and shadow agree exactly and nothing here
|
||||
# could ever go red - which is precisely what the committed evidence did.
|
||||
s47check("PRECONDITION: the cap BINDS - the live run's trade is sized by the "
|
||||
f"guard on every charging cycle, never reaching the {MAX_W:.0f} W ask",
|
||||
_s47_lc and all(abs(r["power_w"]) < MAX_W - 1.0 for r in _s47_lc))
|
||||
s47check("...and the live METER is what closed the gap: it is held up at the "
|
||||
f"{S45_CAP_W:.0f} W ceiling rather than sitting at the "
|
||||
f"{S45_LOAD_W:.0f} W house, which is the feedback a shadow run does not "
|
||||
f"have",
|
||||
S47_LIVE["grid_hi"] > S45_LOAD_W + 200.0)
|
||||
s47check("...and the SHADOW meter sees the house and nothing else for the whole "
|
||||
"run, which is what makes its billed quarter a different quarter",
|
||||
near(S47_SHAD["grid_lo"], S45_LOAD_W, 0.001)
|
||||
and near(S47_SHAD["grid_hi"], S45_LOAD_W, 0.001))
|
||||
|
||||
# --- 3d-2. WHY THE OLD SHAPE COULD NOT FAIL --------------------------------
|
||||
# Graded as an EXPECTATION rather than left as a footnote, so that nobody
|
||||
# rebuilds a check on `[0]` and believes it covers something.
|
||||
print(f" first charging cycle: live {_s47_lc[0]['power_w']:+.4f} W, "
|
||||
f"shadow {_s47_sc[0]['power_w']:+.4f} W")
|
||||
s47check("⚠️ THE FIRST CHARGING CYCLE IS IDENTICAL IN BOTH RUNS EVEN HERE, so "
|
||||
"widening SAFETY-10 §6's fixture ALONE would not have made its table go "
|
||||
"red: at elapsed=0 the projection IS the held level and neither plant "
|
||||
"has moved yet. Both reasons had to be closed, and this is the one a "
|
||||
"reviewer cannot see from a diff",
|
||||
_s47_lc[0]["power_w"] == _s47_sc[0]["power_w"]
|
||||
and _s47_lc[0]["reason"] == _s47_sc[0]["reason"])
|
||||
|
||||
# --- 3d-3. AND ACROSS THE WHOLE RUN THEY DIVERGE ---------------------------
|
||||
_s47_mis = sum(1 for i in range(_s47_n)
|
||||
if _s47_lc[i]["power_w"] != _s47_sc[i]["power_w"])
|
||||
_s47_worst = min(_s47_sc, key=lambda r: r["power_w"])
|
||||
_s47_live_worst = min(_s47_lc, key=lambda r: r["power_w"])
|
||||
# ⚠️ NaN AND NOT AN EXCEPTION when the sentinel above is in play: `nan > 2.0`
|
||||
# is False, so the check goes RED, while a ZeroDivisionError here would kill
|
||||
# the file and report zero reds. Same defect, one line further down - it was
|
||||
# driven, and it is why this is not a plain division.
|
||||
_s47_over = (abs(_s47_worst["power_w"]) / abs(_s47_live_worst["power_w"])
|
||||
if _s47_live_worst["power_w"] else float("nan"))
|
||||
print(f" size mismatches {_s47_mis}/{_s47_n} charging cycles; the shadow "
|
||||
f"run records {_s47_worst['power_w']:+.0f} W where the live run's "
|
||||
f"hardest trade is {_s47_live_worst['power_w']:+.1f} W - "
|
||||
f"{_s47_over:.2f}x")
|
||||
s47check("ACROSS THE WHOLE RUN the recorded trade size diverges on all but the "
|
||||
"first few cycles - the check SAFETY-10 §6 should have been",
|
||||
_s47_mis > 0.9 * _s47_n)
|
||||
s47check(f"...and the shadow run RECORDS a trade the live run never commanded, "
|
||||
f"over by {_s47_over:.2f}x. `900/remaining` amplifies a "
|
||||
f"(ceiling - projected) gap the battery never closed, and the row "
|
||||
f"carried that number to a commissioning engineer with no caveat",
|
||||
_s47_over > 2.0)
|
||||
s47check("...and the amplification is IN THE HEADROOM, which is where the "
|
||||
f"measurement enters: the shadow guard offers up to "
|
||||
f"{max(r['headroom_w'] for r in _s47_sc):.0f} W of charging headroom "
|
||||
f"against a {S45_CAP_W:.0f} W ceiling and a {S45_LOAD_W:.0f} W house, "
|
||||
f"while the live guard never exceeds "
|
||||
f"{max(r['headroom_w'] for r in _s47_lc):.0f} W",
|
||||
max(r["headroom_w"] for r in _s47_sc) > MAX_W
|
||||
and max(r["headroom_w"] for r in _s47_lc) < MAX_W)
|
||||
|
||||
# --- 3d-3b. THE SENTENCE THE ROW PRINTS, GRADED AS ARITHMETIC --------------
|
||||
# ⚠️ THE ROW CLAIMS THE RECORDED NUMBER IS AN **UPPER BOUND**, and a claim on
|
||||
# an operator-facing surface is a claim this file has to be able to fail.
|
||||
# Charging only ADDS offtake, so a live `projected` is never below a shadow
|
||||
# one and the headroom is never above it. The earlier wording said "smaller",
|
||||
# which is FALSE on every cycle where the two are equal - the start of each
|
||||
# quarter, where `900/remaining` is 1.0 and neither plant has moved.
|
||||
_s47_below = [i for i in range(_s47_n)
|
||||
if abs(_s47_sc[i]["power_w"]) < abs(_s47_lc[i]["power_w"]) - 1e-9]
|
||||
_s47_equal = sum(1 for i in range(_s47_n)
|
||||
if abs(_s47_sc[i]["power_w"]) == abs(_s47_lc[i]["power_w"]))
|
||||
print(f" the shadow record is below the live command on "
|
||||
f"{len(_s47_below)}/{_s47_n} cycles and exactly equal on {_s47_equal}")
|
||||
s47check("the recorded size is an UPPER BOUND on the live one, on every compared "
|
||||
"cycle - which is the sentence `shadow.SIZED_FROM_METER` puts on the "
|
||||
"status row, so the row is making a claim this file can fail",
|
||||
not _s47_below)
|
||||
s47check("...and it is NOT strictly greater: the two are equal at the start of "
|
||||
f"each quarter ({_s47_equal} cycles here), which is why the row says "
|
||||
f"'upper bound' and not 'smaller' - the second would be a false "
|
||||
f"sentence on exactly those cycles",
|
||||
_s47_equal > 0)
|
||||
|
||||
# ⚠️ AND THE MECHANISM BEHIND THE BOUND, AS TWO POINTS OF THE SHIPPED
|
||||
# ARITHMETIC RATHER THAN AS ONE PROPERTY OF A WHOLE RUN. Same ceiling, same
|
||||
# elapsed, same house: one quarter that carried the battery's charge at the
|
||||
# meter (LIVE) and one that did not (SHADOW). The closed-loop version above
|
||||
# cannot be driven red by any mutation that ALSO stops the fixture trading -
|
||||
# measured - so the relation it rests on is graded directly here.
|
||||
def _s47_headroom(*, meter_w, batt_w, elapsed_s=450.0):
|
||||
"""`charge_headroom_w()` for a quarter that banked `meter_w` for
|
||||
`elapsed_s`, with `batt_w` measured at the pack. All shipped."""
|
||||
avg = QuarterAverager(phases=1, max_hold_s=900.0)
|
||||
t = 0.0
|
||||
while t <= elapsed_s:
|
||||
imp, exp = split_signed(meter_w)
|
||||
avg.add(make_sample("ha_signed", imp, exp, phases=1,
|
||||
ingest_ts=S45_T0 + timedelta(seconds=t),
|
||||
ingest_mono=(S45_T0.timestamp() + t)))
|
||||
t += 5.0
|
||||
pk = _pg.decide(
|
||||
PeakTracker.project(avg, S45_T0 + timedelta(seconds=elapsed_s)),
|
||||
batt_w=batt_w, cap_w=S45_CAP_W, reading=None, achievable_w=MAX_W,
|
||||
soc=50.0, soc_floor=20.0, max_hold_s=900.0, frozen=False)
|
||||
return _pg.charge_headroom_w(pk)
|
||||
|
||||
|
||||
_S47_TRADE_W = 300.0
|
||||
_s47_h_shadow = derived(lambda: _s47_headroom(meter_w=S45_LOAD_W, batt_w=0.0))
|
||||
_s47_h_live = derived(lambda: _s47_headroom(
|
||||
meter_w=S45_LOAD_W + _S47_TRADE_W, batt_w=-_S47_TRADE_W))
|
||||
print(f" half-way through one quarter, {S45_LOAD_W:.0f} W house under a "
|
||||
f"{S45_CAP_W:.0f} W ceiling: the SHADOW meter (battery at 0 W) offers "
|
||||
f"{_s47_h_shadow:.0f} W of headroom, the LIVE meter (the same house "
|
||||
f"plus a {_S47_TRADE_W:.0f} W charge) offers {_s47_h_live:.0f} W")
|
||||
s47check("the SHADOW meter offers STRICTLY MORE charging headroom than the "
|
||||
"live one on the same house, same ceiling and same elapsed - which "
|
||||
"is the whole mechanism, in two points of the shipped arithmetic "
|
||||
"rather than as a property of a whole run",
|
||||
_s47_h_shadow > _s47_h_live)
|
||||
s47check("...and the live answer is the one that lands the block ON the "
|
||||
"ceiling, so the shadow answer is the one that is wrong about the "
|
||||
"bill rather than the other way round",
|
||||
near(_s47_h_live, S45_CAP_W - S45_LOAD_W, 1.0))
|
||||
|
||||
# --- 3d-4. WHAT SURVIVES OF THE EXEMPTION, GRADED --------------------------
|
||||
# The narrowed claim the three documents now make, as a check rather than as a
|
||||
# sentence: WHICH hour and WHY are unaffected; HOW HARD is not.
|
||||
s47check("WHICH hour the strategy picked and at WHAT price are identical on "
|
||||
f"every one of the {_s47_n} compared cycles - the clock and the price "
|
||||
f"series are not functions of what the battery did, which is the half "
|
||||
f"of the old exemption that is still true",
|
||||
all(_s47_lc[i]["price"] == _s47_sc[i]["price"] for i in range(_s47_n)))
|
||||
s47check("...and so is the spread it had to clear",
|
||||
all(_s47_lc[i]["spread"] == _s47_sc[i]["spread"]
|
||||
for i in range(_s47_n)))
|
||||
|
||||
# --- 3d-5. THE CLOSED-LOOP DEFECT THE DOCUMENTS SAID WAS VISIBLE -----------
|
||||
# ⚠️ SAFETY-10's HEADER NAMED SAFETY-45's LIMIT CYCLE AS EXAMPLE #1 OF WHAT A
|
||||
# SHADOW RUN SURFACES. 3c's own PRECONDITION establishes that the unsized loop
|
||||
# really does run away; the same stimulus watched from inside shadow mode is
|
||||
# a settled, uneventful hour.
|
||||
print(f" SAFETY-45's own defect, unsized: live {S45_BEFORE['onsets']} "
|
||||
f"onsets/swing {S45_BEFORE['swing']:.0f} W, guard engaged "
|
||||
f"{S45_BEFORE['engaged']}/{S45_BEFORE['cycles']} -> in shadow mode "
|
||||
f"{S47_UNSIZED_SHAD['onsets']} onsets/swing "
|
||||
f"{S47_UNSIZED_SHAD['swing']:.0f} W, guard engaged "
|
||||
f"{S47_UNSIZED_SHAD['engaged']}/{S47_UNSIZED_SHAD['cycles']}")
|
||||
s47check("⚠️ SAFETY-45's LIMIT CYCLE IS NOT VISIBLE FROM A SHADOW RUN, and three "
|
||||
"merged documents said it was. The same hour, the same unsized code: "
|
||||
f"{S45_BEFORE['onsets']} charge onsets and a "
|
||||
f"{S45_BEFORE['swing']:.0f} W grid swing live, "
|
||||
f"{S47_UNSIZED_SHAD['onsets']} onsets and "
|
||||
f"{S47_UNSIZED_SHAD['swing']:.0f} W in shadow",
|
||||
S45_BEFORE["onsets"] >= 10 and S45_BEFORE["swing"] > 2000.0
|
||||
and S47_UNSIZED_SHAD["onsets"] <= 2
|
||||
and S47_UNSIZED_SHAD["swing"] < 1.0)
|
||||
s47check("...and neither are the guard ENGAGEMENTS the same documents promised: "
|
||||
f"{S45_BEFORE['engaged']} engaged cycles live against "
|
||||
f"{S47_UNSIZED_SHAD['engaged']} in shadow. Every term of "
|
||||
f"`wanted = batt_w + excess` is MEASURED, and in shadow mode the "
|
||||
f"battery contributes nothing to either term",
|
||||
S45_BEFORE["engaged"] > 100 and S47_UNSIZED_SHAD["engaged"] == 0)
|
||||
|
||||
# --- 3d-6. THE THREE RUNGS OF `sized_from_meter()`, SEPARATED --------------
|
||||
# TEST-16's rule: three rungs answer one question, so each is reached with the
|
||||
# other two clear. Any two of them left standing would mask the third.
|
||||
_s47_chg = _s47_worst
|
||||
_s47_sell = derived(lambda: act(PLAN, DEAR_H, thresh=_shipped, unc=NO_WEATHER,
|
||||
headroom=0.0))
|
||||
s47check("the CHARGE rung: a metered headroom that sized a buy leg answers True, "
|
||||
"which is the state the caveat exists for",
|
||||
_arb.sized_from_meter(
|
||||
ArbitrageDecision(action=CHARGE, power_w=-300.0, reason="x",
|
||||
spread_eur_kwh=1.0, required_eur_kwh=0.1,
|
||||
price_now_eur_kwh=0.05),
|
||||
300.0, winner=_arb.SOURCE) is True)
|
||||
s47check("...the SELL rung: a DISCHARGE answers False however the headroom reads. "
|
||||
"§9.1 - discharge and export are never capped by the peak guard - so a "
|
||||
"caveat on a sell would be a FALSE sentence on the status row",
|
||||
_s47_sell.action == DISCHARGE
|
||||
and _arb.sized_from_meter(_s47_sell, 300.0, winner=_arb.SOURCE) is False)
|
||||
s47check("...the UNMEASURED rung: a None headroom answers False. Nothing sized "
|
||||
"anything from a meter, so there is nothing to disclose - and `decide()` "
|
||||
"refuses the trade there anyway",
|
||||
_arb.sized_from_meter(
|
||||
ArbitrageDecision(action=CHARGE, power_w=-300.0, reason="x",
|
||||
spread_eur_kwh=1.0, required_eur_kwh=0.1,
|
||||
price_now_eur_kwh=0.05),
|
||||
None, winner=_arb.SOURCE) is False)
|
||||
s47check("...the WINNER rung: the same sized charge answers False once something "
|
||||
"else owns the resolution. `Resolution.target_w` is then somebody "
|
||||
"else's number and a caveat filed against it would be false",
|
||||
_arb.sized_from_meter(
|
||||
ArbitrageDecision(action=CHARGE, power_w=-300.0, reason="x",
|
||||
spread_eur_kwh=1.0, required_eur_kwh=0.1,
|
||||
price_now_eur_kwh=0.05),
|
||||
300.0, winner="loop") is False)
|
||||
|
||||
# --- 3d-7. THE ROW, AT THE WORST CYCLE -------------------------------------
|
||||
_s47_row = _s47_chg["row"]
|
||||
_s47_first_row = _s47_sc[0]["row"]
|
||||
print(f" worst cycle row: {_s47_row[:230]}")
|
||||
s47check("the shipped row carries the caveat at the worst cycle: the operator is "
|
||||
"told the number was sized from a meter with only the house in it",
|
||||
_shadow.SIZED_FROM_METER in _s47_row)
|
||||
s47check("...and it still carries the watts, in their own slot, and the standing "
|
||||
"0 W beside them - the caveat NARROWS the claim rather than deleting "
|
||||
"the record a shadow run exists to produce",
|
||||
"WOULD HAVE COMMANDED" in _s47_row and "inverter held at 0 W" in _s47_row
|
||||
and f"{round(_s47_chg['would_w']):+d}".replace("+", "") != "")
|
||||
s47check("...and the watts are introduced as what it would have commanded ON "
|
||||
"THIS CYCLE, in every shadow state and not only the caveated ones - no "
|
||||
"number a shadow run records is a forecast of a live run",
|
||||
"ON THIS CYCLE WOULD HAVE COMMANDED" in _s47_row
|
||||
and "ON THIS CYCLE WOULD HAVE COMMANDED" in _s47_first_row)
|
||||
|
||||
# --- 3d-7b. THE ACTION LOG, WHICH IS THE RECORD READ AFTERWARDS -----------
|
||||
# ⚠️ THE TWO SURFACES ARE GRADED SEPARATELY BECAUSE THEY FAILED SEPARATELY.
|
||||
# Driven as one mutation, deleting the caveat from the log line alone left all
|
||||
# 29 files green: the only check that could see that line drives a fixture with
|
||||
# `meter_source: off`, where no arbitrage decision - and therefore no caveat -
|
||||
# is reachable. The sentence is `shadow.log_line()` now, so it can be graded.
|
||||
_s47_log = derived(lambda: _shadow.log_line(
|
||||
would_w=_s47_chg["would_w"], reason="arbitrage -> -2000 W",
|
||||
sized_from_meter=_s47_chg["sized_from_meter"]))
|
||||
_s47_log_plain = derived(lambda: _shadow.log_line(
|
||||
would_w=_s47_chg["would_w"], reason="loop -> -300 W",
|
||||
sized_from_meter=False))
|
||||
print(f" action log: {_s47_log[:190]}")
|
||||
s47check("the ACTION LOG line carries the same caveat the row does - a page that "
|
||||
"discloses and a 40-row record that does not is the worse half of the "
|
||||
"two, because the record is what is read after the run",
|
||||
_shadow.SIZED_FROM_METER in _s47_log)
|
||||
s47check("...and it is the SAME constant, not a second wording of it, so the two "
|
||||
"surfaces cannot start disagreeing about which cycles are caveated",
|
||||
_shadow.SIZED_FROM_METER in _s47_row and _shadow.SIZED_FROM_METER
|
||||
in _s47_log)
|
||||
s47check("...and an uncaveated cycle gets the plain sentence, so the caveat is "
|
||||
"not simply printed on everything",
|
||||
_shadow.SIZED_FROM_METER not in _s47_log_plain
|
||||
and "would have commanded" in _s47_log_plain
|
||||
and "ON THIS CYCLE" in _s47_log_plain)
|
||||
|
||||
# --- 3d-8. ⚠️ AND IT IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED ----------
|
||||
# THE TRAP THIS PART EXISTS TO SPRING. `arbitrage`'s own sentence says "SIZED
|
||||
# BY THE CAPACITY-TARIFF GUARD" only when the headroom came out BELOW the ask.
|
||||
# In a shadow run that is the START of the quarter - where the two runs still
|
||||
# agree to the float. By the end `900/remaining` has multiplied the headroom
|
||||
# PAST the ask, the trade is NOT capped, the sentence is silent, and the
|
||||
# recorded number is at its most wrong. A caveat keyed on that sentence would
|
||||
# be quietest exactly where it is needed loudest.
|
||||
_S47_CAPPED = "SIZED BY THE CAPACITY-TARIFF GUARD"
|
||||
print(f" at the worst cycle the shipped trade sentence says "
|
||||
f"{'' if _S47_CAPPED in _s47_chg['reason'] else 'NOT '}capped; at the "
|
||||
f"first it says "
|
||||
f"{'' if _S47_CAPPED in _s47_sc[0]['reason'] else 'NOT '}capped")
|
||||
s47check("PRECONDITION: the shipped 'capped' sentence IS present at the first "
|
||||
"charging cycle, where the shadow number is RIGHT - so the inverse "
|
||||
"below is a real inversion and not an absence everywhere",
|
||||
_S47_CAPPED in _s47_sc[0]["reason"])
|
||||
s47check("⚠️ ...and ABSENT at the worst cycle, where the shadow number is "
|
||||
f"{_s47_over:.2f}x out. A caveat keyed on `capped` would fire only "
|
||||
f"where the record is accurate and go silent where it is multiples "
|
||||
f"wrong; `sized_from_meter()` is keyed on the headroom having been "
|
||||
f"MEASURED, so it fires on both",
|
||||
_S47_CAPPED not in _s47_chg["reason"]
|
||||
and _s47_chg["sized_from_meter"] is True
|
||||
and _s47_sc[0]["sized_from_meter"] is True)
|
||||
|
||||
# --- 3d-9. main.py's CALL SITES, PINNED ------------------------------------
|
||||
# ⚠️ THE CALL SITE IS THE UNIT OF COVERAGE (habit 15), same as 3b's. Nothing
|
||||
# behavioural in this file can see main.py render the row with a hard-coded
|
||||
# False, because every check above calls `shadow.words()` itself.
|
||||
_s47_words = [n for n in ast.walk(_S45_MAIN_TREE)
|
||||
if isinstance(n, ast.Call)
|
||||
and ast.unparse(n.func).endswith("shadow.words")]
|
||||
_s47_flag = [ast.unparse(k.value) for c in _s47_words for k in c.keywords
|
||||
if k.arg == "sized_from_meter"]
|
||||
_s47_flag_src = _s45_assigned("shadow_sized_from_meter",
|
||||
clear=("None", "False"))
|
||||
print(f" main.py: shadow.words(sized_from_meter={_s47_flag}), and "
|
||||
f"self.shadow_sized_from_meter is assigned from {_s47_flag_src}")
|
||||
s47check("main.py renders the row from the flag THE CYCLE RECORDED, at its one "
|
||||
"shadow.words() call site - not from a literal and not re-derived on "
|
||||
"the status task, where `self.peak_guard` is a different cycle's",
|
||||
_s47_flag == ["self.shadow_sized_from_meter"])
|
||||
s47check("...and that flag comes from the SHIPPED predicate with all three of its "
|
||||
"arguments - the decision, the headroom the trade was sized from, and "
|
||||
"the arbiter's winner - so a mutation to `False`, to a literal or to a "
|
||||
"two-argument transcription is red rather than silent",
|
||||
_s47_flag_src == ["arbitrage.sized_from_meter("
|
||||
"self.arb, self.arb_headroom_w, "
|
||||
"winner=resolution.winner)"])
|
||||
_s47_logcalls = [n for n in ast.walk(_S45_MAIN_TREE)
|
||||
if isinstance(n, ast.Call)
|
||||
and ast.unparse(n.func).endswith("shadow.log_line")]
|
||||
_s47_logflag = [ast.unparse(k.value) for c in _s47_logcalls for k in c.keywords
|
||||
if k.arg == "sized_from_meter"]
|
||||
print(f" main.py: shadow.log_line(sized_from_meter={_s47_logflag})")
|
||||
s47check("...and the ACTION LOG line comes from the shipped sentence with the "
|
||||
"same flag, at main.py's one call site - not re-assembled as an "
|
||||
"f-string where no check can reach it, which is how it survived a whole "
|
||||
"mutation battery once already",
|
||||
_s47_logflag == ["self.shadow_sized_from_meter"])
|
||||
# ⚠️ AND THE PARAMETER HAS NO DEFAULT. TEST-14's rule, and this card is the
|
||||
# reason it matters here: a caller that FORGOT the caveat and a caller that
|
||||
# DECIDED it did not apply would render the identical row.
|
||||
_s47_sig = inspect.signature(_shadow.words)
|
||||
_s47_logsig = inspect.signature(_shadow.log_line)
|
||||
s47check("`shadow.words()` and `shadow.log_line()` BOTH require "
|
||||
"`sized_from_meter` - no default on either, so a caller cannot omit the "
|
||||
"caveat by accident and get the un-caveated surface",
|
||||
"sized_from_meter" in _s47_sig.parameters
|
||||
and _s47_sig.parameters["sized_from_meter"].default
|
||||
is inspect.Parameter.empty
|
||||
and "sized_from_meter" in _s47_logsig.parameters
|
||||
and _s47_logsig.parameters["sized_from_meter"].default
|
||||
is inspect.Parameter.empty)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
|
||||
@@ -2938,10 +2938,19 @@ check("...and it is inert BY CONSTRUCTION, not by a special case: the value it "
|
||||
# controller command NOW, from a battery at 0 W" - ONE STEP - and not "what
|
||||
# trajectory would it have followed". The trajectory is a closed-loop property
|
||||
# and it did not happen; reporting it would be a simulation of a plant that
|
||||
# does not exist. The strategies are unaffected: arbitrage, the peak guard and
|
||||
# maintenance all file SET claims at a fixed power from level-triggered inputs,
|
||||
# which is why the three defects this card was written for are all visible from
|
||||
# a shadow run and this one is not.
|
||||
# does not exist.
|
||||
#
|
||||
# ⚠️ AMENDED BY SAFETY-47. The three lines that stood here said "the strategies
|
||||
# are unaffected ... which is why the three defects this card was written for
|
||||
# are all visible from a shadow run and this one is not." That was true until
|
||||
# SAFETY-45 merged, one commit earlier: the buy leg is now sized from the
|
||||
# BILLED-QUARTER METER, which is a function of what the battery did. So this is
|
||||
# NOT the loop leg's own limitation - it is the GENERAL case, and the loop leg
|
||||
# is merely where it had already been noticed. A shadow run cannot surface any
|
||||
# closed-loop defect, and of the three this card was written for exactly one -
|
||||
# TARIFF-14's wrong quarter-hour - is visible from one. `test_arbitrage.py`
|
||||
# part 3d grades that; this check keeps grading the loop leg, which is what it
|
||||
# has always been for.
|
||||
check("RECORDED LIMITATION: the loop leg's shadow decision is ONE slew step "
|
||||
"from the standing command and stays there, while the live run RAMPS. A "
|
||||
"shadow run answers 'what would it do now', not 'what trajectory would "
|
||||
|
||||
Reference in New Issue