A charger reading missing for less than stale_input_s keeps the last trusted reading (CarTracker, shared by Solar, Manual and the peak guard). Nothing is decided or written in that cycle, and the gap neither arms nor clears the stuck check. At stale_input_s the existing safe path applies. This also ends the false PEAK_GUARD_FLOOR_LIMITED after one gap.
On ha_signed, Solar's unknown-sun pause comes when the meter's age reaches meter_max_age_s + ev_pause_min (330 s), checked every cycle.
Rows are in test_ev20_rig.py section 7 and test_ev18.py (T-gap, T10(b)). Details are in reports/EV-20-dev-report.md, section "Rig round 2".
EV-20 rig round 2 (rig FAIL on merge 09b6af9), PM rulings.
- A charger reading missing for less than `stale_input_s` keeps the last trusted reading (`CarTracker`, shared by Solar, Manual and the peak guard). Nothing is decided or written in that cycle, and the gap neither arms nor clears the stuck check. At `stale_input_s` the existing safe path applies. This also ends the false PEAK_GUARD_FLOOR_LIMITED after one gap.
- On `ha_signed`, Solar's unknown-sun pause comes when the meter's age reaches `meter_max_age_s` + `ev_pause_min` (330 s), checked every cycle.
Rows are in `test_ev20_rig.py` section 7 and `test_ev18.py` (T-gap, T10(b)). Details are in reports/EV-20-dev-report.md, section "Rig round 2".
🤖 Generated with [Claude Code](https://claude.com/claude-code)
https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
A charger reading missing for less than stale_input_s keeps the last trusted
reading in CarTracker (shared by Solar, Manual and the peak guard): no
decision or write in that cycle, no stuck arm or clear. At stale_input_s the
safe path is unchanged. This also stops the false PEAK_GUARD_FLOOR_LIMITED
after one gap (EV-18 T10(b) updated). On ha_signed Solar's unknown-sun pause
comes at meter age meter_max_age_s + ev_pause_min, checked every cycle.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
A failed read or every required entity unavailable is a gap and keeps the
last reading; one entity missing, a wrong power unit or login off stay the
reading they are (EV-03 round 4 rows green again).
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
While the meter's age is past meter_max_age_s, or on a held charger read,
Solar sends no non-zero current: no retry, no raise, no phase change begun,
and a phase change under way ends at its 0 A. 0 A is always allowed. On a
held read Solar still steps (Manual does not), so a pause due then is not
slipped. Rows in test_ev20_rig.py section 8.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
A retry on a held cycle went to a charger that was not answering and changed
the try count (test_ev20_fuzz T54 N14, seed 1). Held cycles now allow only a
new 0 A decision, such as the age pause.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
The C17 branch (end a phase change at its 0 A and pause) ran on a held read
too, so one failed read just after a select stopped the car for the 600 s
phase gap. A held read now leaves the change alone; it goes on at the next
real reading. The silent meter still ends it at its 0 A. Rows: test_ev20_rig
section 9.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
On a held charger read no writer steps and the Solar plan does nothing: no
phase change or switching start begins, no _set or end_switch, ok_since,
up_since, down_since, low_since and set_at stay, and the hold pause does not
fire; a decision due then runs on the next real reading. The one exception
is the pause by the meter's age (C18, SolarWriter.held_pause). Rows: the
reviewer's three shapes with 1- and 2-read gaps on and before the decision
cycle, and the hold pause on a held cycle. DECISIONS wording fixed.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
EV-20 rig round 2 (rig FAIL on merge
09b6af9), PM rulings.stale_input_skeeps the last trusted reading (CarTracker, shared by Solar, Manual and the peak guard). Nothing is decided or written in that cycle, and the gap neither arms nor clears the stuck check. Atstale_input_sthe existing safe path applies. This also ends the false PEAK_GUARD_FLOOR_LIMITED after one gap.ha_signed, Solar's unknown-sun pause comes when the meter's age reachesmeter_max_age_s+ev_pause_min(330 s), checked every cycle.Rows are in
test_ev20_rig.pysection 7 andtest_ev18.py(T-gap, T10(b)). Details are in reports/EV-20-dev-report.md, section "Rig round 2".🤖 Generated with Claude Code
https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2768755, infra pin bump #273) into EV-20-r2