SAFETY-128: control does not act on late Home Assistant readings #228

Merged
admin merged 3 commits from SAFETY-128 into release/1.0 2026-11-02 05:49:08 +01:00
3 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5.5 7de77a5a09 SAFETY-128 review: DECISIONS states the slow-battery limit as measured
checks / unit (pull_request) Successful in 32m0s
infra-pin / fresh (pull_request) Successful in 1s
Round 2 review: a 10 s dead time reads late at 1-2 s meters, and a 15-20 s
lag gives late fits; the note said 3-20 s and 6-10 s gave none.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-02 05:16:28 +01:00
glenn schrooyenandClaude d3f4f9f48b SAFETY-128 round 2: find late readings from the batteries, not the meter alone
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
Review B1: the meter fit took repeating house loads (ovens, a heat pump)
for late readings on healthy 1-2 s sites, about 9 % of the recorded
house. B2: at a 5 s meter it never ran. M1: no hysteresis. M2: an
unbounded check.

lateness.Delay now fits how long each battery's reading takes to show
its own request, which the house does not move, from the 1 s reads
(read_inputs -> Answer.watch). The meter fit stays for speed at 1-3 s
meters, but counts only when an ask was slow to start and no battery
fit said on time. Late from 9.5 s after 2 fits, on time under 6.5 s,
dropped after 120 s without a fit. Fits are bounded (a few ms).

Readings on time: no verdict in any reviewer scenario (22 shapes at
1/2/5 s meters, 7 harm runs) nor in 2 days of the recorded house at
1, 2 and 5 s ticks; digests equal to 77fe31b. Late: found 36-68 s after
the start at 1-2 s, about 3 min at 5 s. The row gives the batteries'
delay, or no figure while only the meter has shown it.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-02 04:32:04 +01:00
glenn schrooyenandClaude 09e1fbb898 SAFETY-128: control does not act on late Home Assistant readings
checks / unit (pull_request) Successful in 19m36s
infra-pin / fresh (pull_request) Successful in 1s
Readings that Home Assistant delivers late but still changing passed
every staleness gate, so the loop corrected again each cycle an error
its last command had already fixed (10 s late: the give run swung and
exported to -1.9 kW), and the peak guard pushed to the inverter limit
on the same late figures (OPT-34 F-2).

app/lateness.py fits how long after a power request the meter shows
it. Over 8 s the readings are late: a request the battery reading has
not answered holds the loop (it may not lead the reading by more than
100 W) and caps the peak guard at what stands; unanswered for 23 s it
holds, then 0 W after stale_input_s. An amber row and one log line per
episode say so. With readings on time nothing changes (digests equal).

DECISIONS/SAFETY-128-late-readings.md; test_safety128.py.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC