glenn schrooyenandClaude a0ace389a4 UX-54 round 6: the floor cut in one step, never from an empty battery
checks / unit (pull_request) Successful in 50m21s
infra-pin / fresh (pull_request) Successful in 1s
daycurve._floor_cut() set a cut from a battery already at the floor (its
cap 0 is below its rating), so a give run with one battery empty and the
other held to its rating was cut until MAX_FLOOR_CUTS ran out: 2,800 cuts
and 460 ms a build, and give blocks back at the hour edge after that.

The shortfall in a step is now shared as control shares it (by what each
battery holds above the floor, packshare.weights(), each at most its
rating, the rest passed on), in the step and in the cut. A battery giving
v kW that holds h kWh is empty at h / v; one at the floor holds nothing and
never sets a cut. The cut lands where the step then comes out exact, so it
is placed once. curve(stats=) reports the floor cuts and whether the bound
stopped one.

test_ux54.py: _floor_cut() checked to the second against floor times worked
out by hand (one battery, a group with one held to its rating, the second
group, the split by what they hold), a battery at the floor sets no cut,
the bound is reported; own_walk() with the reviewer's two cases (30/80 %,
guard, 7 kW house; 2 x 3 kW, 3.5 kW house) and, per build, the floor cuts,
the level points and the time.

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 19:03:56 +01:00
glenn schrooyenandClaude a4b769f257 UX-54 round 5: test_ux54_dst.py points at MUTATION.md (test_bytecode.py)
checks / unit (pull_request) Successful in 50m12s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 16:19:07 +01:00
glenn schrooyenandClaude 8dbf831854 UX-54 round 5: give blocks end at the floor point, the tab on the clock-change days
checks / unit (pull_request) Failing after 50m11s
infra-pin / fresh (pull_request) Successful in 1s
daycurve.curve() puts a point where a giving battery reaches the floor
inside a step (_floor_cut(), as it already does for a grid charge reaching
its level), so _stops() ends a give block in the quarter control stops. A
walk where control moves the packs with its own model (not the curve's
levels) matches the tab quarter by quarter in 11 cases; 25/45 % with the
peak guard: control 17:00-20:15, block 17:00-20:06.

SolarToday keys an hour by its start taken back from the UTC instant, so
the two 02:00 hours of the autumn change stay apart. test_ux54_dst.py builds
the tab (forecast_payload()) at every quarter of 27-29 March and
30 October-1 November 2027, modes on and off, in the no-tzdata zone and,
where the host has tzdata, ZoneInfo, every call under a time limit raised
as a BaseException that forecast_payload() cannot swallow.

give_later: "No block shows while a battery has no energy to give." /
"Er verschijnt geen blok zolang een batterij niets kan leveren."
DECISIONS: what the walks prove, the modes-off charge drawn on a sunny day,
the clock-change days.

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 15:54:33 +01:00
glenn schrooyenandClaude 00c8ae354c Merge release/1.0 (f5afb42, SAFETY-123) into UX-54
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 15:30:52 +01:00
glenn schrooyenandClaude 4256bd3eda UX-54 round 4: modes off reads tomorrow at Home's count, no relabel in the walk
checks / unit (pull_request) Successful in 48m51s
infra-pin / fresh (pull_request) Successful in 2s
Modes off has no curve (no forecast is read, no house profile kept), so
dayview._levels() never ran there and tomorrow's legs were drawn from the
bound. homeview.trade_runs(ahead=f) now reads each leg at f(name, kind,
start), as mode_runs() does: no give while the emptiest battery is at the
floor, each share sized from that level. dayview._counted() gives a give
the level by Home's own count (the level now, plus what the blocks before
it put in, less what they take out); a charge is read from the floor,
because a full battery covers the house before the cheap hour.

The battery line says a give is planned when one is and the battery has
no give block, also with modes off.

test_ux54.py: the modes-on walk no longer relabels a GIVE role at the
floor; it asks control's own discharge envelope (packshare.envelope())
with each pack's cut-out at the floor. The peak-guard 20 % case asserts
the curve is at the floor at the 17:00 give start. A modes-off walk on a
cloudy day (arbitrage.decide() with the cycle's inputs, the packs moved by
what control does and by the house), cases A-D: control charges and gives
in exactly the quarters the tab has a block. trade_runs(ahead=f) unit
check. _stops() ends a give block where the level the tab shows is at the
floor (LEVEL_DP).

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 03:06:12 +01:00
glenn schrooyenandClaude 5ab8622265 UX-54 round 3: tomorrow's blocks last as long as control acts, give blocks checked at run start
checks / unit (pull_request) Successful in 48m22s
infra-pin / fresh (pull_request) Successful in 1s
- Tomorrow's grid block is drawn to where control stops charging. A cheap run
  is sized for all batteries together; a slower one is still below
  `charge_to()` when it ends and control plans the next cheap slots. The tab
  asks `modetrade.energy()` and `priceruns.plan()` with the packs at the
  curve's level and extends the run, so the curve charges as long.
- Each battery's block ends where it is at its own level (grid) or at the
  floor (give). The curve puts a point where a battery reaches its charge
  level inside a step.
- `homeview.mode_runs(ahead=f, rp=...)` reads each block at the level the
  curve has when it starts, with Home's own filter and MIN_KWH: no give block
  at the floor, no grid block at the planned level. Home never passes either.
- `no_tomorrow` names the hour from `solarfc.BELL_FROM_H`, where the curve
  stops.
- test_ux54.py part 7 compares control (`_mode_roles()` every 15 minutes) with
  the tab with no tolerance, and adds the cloudy / floor case.

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 00:53:58 +01:00
glenn schrooyenandClaude 75195f7073 UX-54 round 2: tomorrow's blocks where control will act, trust as the plan counts it, strings
checks / unit (pull_request) Successful in 48m25s
infra-pin / fresh (pull_request) Successful in 1s
F1: tomorrow's blocks no longer depend on the battery's level now. Home sizes
a block from the level now (`room()`, `plan_need()` in mode_runs, the leg
sizing in trade_runs) and draws none when there is no room or energy. For a
day that has not started the builders take `ahead=True` (Home never passes
it): a charge is read from the floor, a give from the ceiling. A grid block is
then kept only where `modetrade.chargers()` would charge at the curve's level
when the run starts. The UX-53 gate is unchanged. Today still equals Home; a
give run in the plan with no block (empty battery) has its own sentence
instead of "No charge or give blocks planned".

F2: test_ux54.py part 7 walks the real `_mode_roles()` every 15 minutes
through tomorrow and compares the roles with the tab's blocks (modes on, the
peak gate, part-full batteries), and the control cycle's verdict at 07:00
(modes off).

F3: the curve counts spare solar as trust x max(0, sun - house), stored at
EFF, as `dayplan.plan()` does (10 kWh sun, 2 kWh house, 70 %: 5.32 kWh).

Strings: cycle, no_tomorrow, ahead, no_level, measured; new give_later.

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-26 22:48:48 +01:00
glenn schrooyenandClaude b6b2d1b184 UX-54: a Forecast tab with the sun, the house and each battery's level, per hour
checks / unit (pull_request) Successful in 48m29s
infra-pin / fresh (pull_request) Successful in 1s
A new tab beside Home and Batteries for today and tomorrow: the solar
forecast, the solar measured so far, the house's expected use and each
battery's expected level, with the plan's own charge and give blocks under it.

- Blocks are Home's: today's are the plan's `runs`, tomorrow's come from the
  same builders (`homeview.runs_for()`), in the plan lines' words.
- The sun is what solarfc reads; a daily total is spread over the bell and the
  tab says so. The house is HouseProfile.estimator(), as the plan reads it.
- The level is new: `daycurve.curve()` gives each battery the role
  `modetrade.decide()` gives it and moves it hour by hour inside the plan's
  floor and ceiling. It is an estimate and counts on `solar_trust_pct`.
- Built on request (`GET forecast`), no Home Assistant call. Measured solar is
  kept per hour in memory from the reading control already takes.
- A part not known yet is a note: modes off, no forecast, learning, no
  forecast for tomorrow, a monthly cycle, no level, stopped, shadow.

No decision, command, timing or option key changes. Found, not changed:
`dayplan.plan()` over-counts a state-only forecast (DECISIONS/UX-54).

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-26 19:38:59 +01:00