OPT-04 landed after the previous rebase. Conflicts were CHANGELOG.md and one
IMPORT LINE in validate.py; both refusal blocks and both option sets survive
untouched, and DOCS.md, main.py and config.yaml auto-merged.
⚠️ AND THE MERGE BROKE A CHECK THAT NEITHER CARD COULD HAVE SEEN ALONE.
test_peakguard.py graded "the first `.decide(` call in main.py" and asserted
there was exactly one. That was true when SAFETY-24 was written; OPT-04 added
`arbitrage.decide(...)`, so the merged tree had two and the assertion failed.
It failed loudly rather than grading the wrong call - the guard did its job -
but it cannot ship red.
Fixed by selecting the call by QUALIFIED NAME (`peakguard.decide`) instead of
by position, and requiring exactly one of THAT. Other modules may now call
their own decide(); this grader can no longer be moved by one of them. Verified
still discriminating: a decoy `peakguard.decide` added to main.py turns it red
on 7 assertions, and the `maintenance_soc_floor` swap still turns it red on 6.
Also folded in the review's wording finding. An assertion read "a CONTROLLER
whose SoC entity does not answer hands decide() None" while driving no
Controller. The wiring property is stronger than the one claimed, and is now
asserted on the SERVICE CALL: a Controller with no SoC never reaches the guard
at all, because `inputs_ok` is False and cycle() stops at the safety claim
first - so a `float(soc or 100)` defaulting line above the call site cannot
disarm the floor. The original decide()-level check is kept, reworded to say
what it actually grades.
Full suite green on the merged tree: 15 files.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
FCST-03 landed while this was in review, so both branches had prepended an
Unreleased stanza. Only CHANGELOG.md conflicted, exactly as predicted;
app/, config.yaml, validate.py and DOCS.md all auto-merged, and this card
touches neither price_forecast.py nor static_tariff.py.
Both stanzas kept verbatim, SAFETY-24's above FCST-03's - no text from
either author edited. Full suite green on the merged tree: 14 files.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
SAFETY-07 can command a discharge to hold a billed quarter down, and
nothing below it consulted the state of charge. On the 2026-08-20 replay
it asks for 878 Wh in a day. Relying on the BMS is not absurd - it is a
real floor and it works - but it is the pack's protection rather than the
operator's, and a month of aggressive quarters leaves the battery
repeatedly at that cut-out with no EMS-side record of why. The first
symptom is a pack never available when wanted, which is indistinguishable
from the SoC drift MAINT-01 exists to correct.
decide() now takes soc and soc_floor, both required and neither
defaulted, and discharge_permitted() is the one place the question is
answered. Above the floor nothing changes. At or below it the guard files
a 0 W floor instead of a sized one - one-directional, so charging stays
blocked and no discharge is capped - and reports floor_limited with the
reason it bound. It is not a trip: every stop in 11.2's table still
outranks the claim, and the floor is never negative, so 9.1's asymmetry
survives as a property of the object (0 negative floors over 1296 swept
combinations, SoC included).
The SoC is graded only after `wanted > 0` is established, so it is never
evaluated where it governs nothing. An unreadable SoC is floor-limited,
not a full battery - a full battery is exactly the value that would
disarm the floor, and this project shipped that defaulting once already.
Failing to shave is not silent: one notification per episode
(goodwe_peak_soc_floor), distinct from the saturation alarm because the
two ask for opposite operator actions, plus its own status row and an
action-log line.
Verified by replay. The 2026-08-20 capture is driven against a modelled
pack sized from the day's own measured appetite, so it genuinely
exhausts: without the floor it reaches the BMS cut-out and holds there
for 1227 guard cycles; with it the pack stops at 20.0 % and never touches
the BMS. The energy withheld equals the energy between the two floors to
within one cycle at the rail. The honest half is reported too - the worst
quarter goes 4338 W -> 5030 W, because a floor-limited guard shaves less
on purpose.
Two new options, mirrored once in peakguard.PEAK_OPTION_DEFAULTS
(TARIFF-02's pattern), imported by validate.py and main.py rather than
typed as literals and pinned to config.yaml by a check that reads the
file - so CFG-03 still tracks three places. validate.py rule 8 refuses
peak_soc_floor <= bms_soc_floor at startup, in CFG-01/MAINT-04's manner.
maintenance_soc_floor is deliberately not reused and not renamed: it is a
drain target, not a spend limit, and the rename is recorded as a decision
to revisit if a third floor appears.
Eleven mutations of the shipped source were run against the checks; all
eleven go red and there are no survivors.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC