Compare commits
3
Commits
v0.17.0
...
ce46a4b76d
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
ce46a4b76d | ||
|
|
eb7a1e754e | ||
|
|
0803149548 |
@@ -2,6 +2,100 @@
|
||||
|
||||
## Unreleased
|
||||
|
||||
**`site_standing` — the one quantity BOTH site guards are asked about — is now
|
||||
pinned by a fixture whose per-unit shares cannot answer for it (SAFETY-38).**
|
||||
`app/main.py`'s `site_standing = float(sum(standing.values()))` is the first
|
||||
argument of [[SAFETY-30]]'s **latching, site-stopping** sign detector *and* the
|
||||
`commanded_w` handed to [[SAFETY-18]]'s `looks_frozen()`. It was pinned by
|
||||
**nothing**, and three mutations of it disarmed both guards with the whole suite
|
||||
green. **This card changes coverage only: not one byte of `app/` moves — the
|
||||
shipped `sum` is correct and must not be "fixed".**
|
||||
|
||||
* **⭐ THE FIXTURE THE SUITE COULD NOT BUILD: per-unit shares EACH BELOW the
|
||||
site gate whose SUM clears it.** Two simulated units rated 220 W and 280 W,
|
||||
both obeying exactly, inverted gain, house importing 2000 W — the site
|
||||
commands **−500 W against a +2500 W meter** and no single share clears the
|
||||
300 W gate. That is the case the site detector exists for, and it is the only
|
||||
arrangement that can separate `sum` from the mean and from the largest share.
|
||||
`test_watchdog.py` part 9a.
|
||||
* **WHY THE EXISTING FIXTURE COULD NOT.** `_sign_site`, the suite's only N≥2
|
||||
site fixture, runs shares of about −2500 W **each** — every one individually
|
||||
over the gate — so sum, mean and largest-share all agree on it. *Its values
|
||||
happen to be equal, and a check comparing two things that happen to be equal
|
||||
cannot see the difference it names.* `MUTATION.md` habit 4, ninth instance,
|
||||
inside the site half of the very card that names it.
|
||||
* **FOUR CANDIDATE REDUCTIONS, FOUR DISTINCT ANSWERS, ONE OVER THE GATE** —
|
||||
`sum` −500, mean −250, `max(key=abs)` −280, `[0]` −220 — and that is asserted
|
||||
as a precondition, not described. The asymmetric ratings are load-bearing:
|
||||
equal shares collapse three of the four onto one number, and the **smaller**
|
||||
unit is first so `[0]` stays distinct from `max(key=abs)`. The **gate is the
|
||||
shipped 300 W**; only the hold is shortened, because the hold is a wall clock.
|
||||
* **⭐ THE SECOND CONSUMER IS COVERED, NOT SCOPED OUT.** The same value is
|
||||
`looks_frozen()`'s `commanded_w` at `main.py:1926`. At the same roster the
|
||||
site rail is 0.95 × 500 = **475 W**, so `sum` = 500 W rails it while 250, 280
|
||||
and 220 do not. Shipped: the peak guard goes blind on SAFETY-18's conjunction
|
||||
and files `floor_w = 0.0`. Under both surviving mutations it is **not blind at
|
||||
all and files no floor**, so the battery may keep importing through a quarter
|
||||
whose billed average is unobservable. `test_watchdog.py` part 9b. The open
|
||||
quarter is deliberately backfilled with the stuck reading so the mutant cannot
|
||||
reach the same action by the *coverage* route and mask the difference.
|
||||
* **AT N=1 NOTHING CHANGES, AND IT IS ASSERTED.** On a real one-inverter
|
||||
controller `standing` has one entry, so `sum`, the mean, `max(key=abs)` and
|
||||
`[0]` are **the same number** — all three mutations are genuinely *equivalent*
|
||||
on a shipped install and no N=1 fixture could ever separate them. Printed and
|
||||
checked, beside the site detector still being absent there. Part 9c.
|
||||
* **⚠️ A CORRECTION, AND IT IS THE MOST USEFUL LINE IN THIS CARD.** An earlier
|
||||
revision of this entry said one of the three — `list(standing.values())[0]` —
|
||||
was **already closed** by [[SAFETY-32]]'s package-wide structural pin, and
|
||||
told future authors not to re-cover it. **That was false.** It had been
|
||||
measured **once**, that run hit `test_peakguard.py`'s [[CI-06]] flake (a
|
||||
measured **~20%** false-red rate), and the red was recorded as a mutation
|
||||
**kill**. Re-measured on `release/1.0` @ `86eaef2` carrying only that edit:
|
||||
the **full 21-file suite is green** and `test_peakguard.py` passes **five for
|
||||
five** in isolation — **the mutation survives.** The reason SAFETY-32 cannot
|
||||
see it is not the shape: part 12j taints names *bound* to roster values and
|
||||
lists *accumulated* in a loop, and `standing` is a dict filled by **subscript
|
||||
assignment**, so it never enters the taint set and `sum(standing.values())` is
|
||||
not a roster site at all. 12j's own enumeration on the mutated tree lists
|
||||
`main.py:1553`, `1555`, `1690` — **not `1599`**. **All three mutations needed
|
||||
this card; all three are now covered by it.** *A single red from
|
||||
`test_peakguard.py` proves nothing — re-run it five times in isolation and
|
||||
name the failing check.*
|
||||
* **⚠️ AND A ZERO-BYTE SURVIVOR ONE LINE BELOW THE ONE THIS CARD PINNED.**
|
||||
Pinning the *value* `site_standing` said nothing about **where it goes**.
|
||||
Swapping the detector's first two arguments —
|
||||
`evaluate(site_standing, self.grid, …)` → `evaluate(self.grid, site_standing, …)`
|
||||
— is **zero bytes** and left the tree fully green, because the check asserted
|
||||
only that `"-500 W"` appeared **somewhere** in the banner. It still does:
|
||||
**in the meter slot.** The swapped banner reads *"commanded +2500 W against a
|
||||
meter reading −500 W"* — a site charging at −500 W into a +2500 W import, told
|
||||
to the operator **exactly backwards**, on the one line somebody woken by a
|
||||
latching site-stopping alarm reads first. The check now asserts the **ordered
|
||||
pair** rather than a substring, and is red on it. **No `app/` change:** the
|
||||
hole was in the test.
|
||||
* **⭐ A SURVIVOR THIS CARD WENT LOOKING FOR AND CLOSED.**
|
||||
`site_standing = float(self.target)` — the arbiter's site *target* instead of
|
||||
the sum of what actually **stands on the wire** — is **−11 bytes** and
|
||||
survived the full suite, because in every fixture that existed the two are the
|
||||
same number. They are not when a device's reported range is narrower than its
|
||||
`max_w`: the `device` claim is filed **per actuator**, so it bounds each
|
||||
unit's share and never the site target. A site asking for −500 W while −250 W
|
||||
stands would then take a **latching site-wide false trip** under its own
|
||||
300 W gate. Closed by part 9a's device-clamped counterfactual.
|
||||
* **13 mutations — 11 of that line and its call site, plus 2 zero-byte edits to
|
||||
the arbiter claim wiring — each on a fresh full-repo copy mounted `:ro`,
|
||||
bytecode purged by `tools/mutation_run.sh`, the edit re-read from disk and the
|
||||
byte delta printed. All 13 red.** Every one was **re-run independently** in
|
||||
this round rather than carried forward from the previous round's report. The
|
||||
claim-wiring pair (`sign_site` and `circulation` moved from site scope to unit
|
||||
scope) closes two gaps a reviewer disclosed — though **`circulation`'s kill
|
||||
belongs entirely to pre-existing checks and is not claimed by this card.**
|
||||
⚠️ One **false red** from `test_peakguard.py` on M10 did not reproduce in four
|
||||
subsequent runs; it is CI-06's known flakiness, no claim here rests on it, and
|
||||
it is recorded rather than quietly dropped — unlike the one that *was*
|
||||
believed, two bullets up. Ledger, and an **enumerated list of what was not
|
||||
mutated**, in `DECISIONS/SAFETY-38-site-standing-pin.md` §4a, §4b and §6a.
|
||||
|
||||
**Inverter B gets its own MQTT device, and inverter A keeps the one it has
|
||||
(TEL-07).** MQTT discovery announced **one** device, and every entity hung off
|
||||
one `unique_id` prefix, so at two inverters B's per-unit telemetry had nowhere
|
||||
|
||||
@@ -0,0 +1,411 @@
|
||||
# SAFETY-38 — pinning `site_standing`, the one quantity both site guards are asked about
|
||||
|
||||
**Status: DECIDED 2026-09-05.** `app/main.py`'s
|
||||
`site_standing = float(sum(standing.values()))` is **correct and is not
|
||||
changed**. What this card adds is the thing it never had: a **behavioural**
|
||||
fixture whose per-unit shares **cannot** answer for the site, so that a change
|
||||
of *meaning* in that reduction goes red instead of green.
|
||||
|
||||
Filed with SAFETY-38, card `6a9ac95f2b78646e5a76d2e9`. It is a **coverage**
|
||||
card: not one byte of `app/` moves.
|
||||
|
||||
---
|
||||
|
||||
## 0. The line, and its two consumers
|
||||
|
||||
```python
|
||||
site_standing = float(sum(standing.values())) # app/main.py:1598
|
||||
```
|
||||
|
||||
`standing` is `{unit name -> the value THIS controller last put on that unit's
|
||||
setpoint entity}` — `inv.last_write`, i.e. the number **after**
|
||||
`clamp_to_rating()` has applied `max_w` and the device's own
|
||||
`[dev_min, dev_max]`. Two safety inputs are derived from it and nothing else in
|
||||
`cycle()` is:
|
||||
|
||||
| consumer | where | what it does with it |
|
||||
|---|---|---|
|
||||
| **[[SAFETY-30]]**'s site sign detector | `self.site_sign_wd.evaluate(site_standing, self.grid, …)` (main.py:1619) | **latches and stops the whole site** when the total command opposes the meter for `site_sign_disagree_s` |
|
||||
| **[[SAFETY-18]]**'s freeze conjunction | `looks_frozen(unchanged_s, site_standing, max_w, …)` inside `peakguard.decide(frozen=…)` (main.py:1926) | takes the peak guard **blind** and files `floor_w = 0.0` — the battery may not import while the billed quarter is unmeasurable |
|
||||
|
||||
Both are P0 paths. **Neither was pinned to the reduction.**
|
||||
|
||||
## 1. What survived, and what the rescope measured
|
||||
|
||||
The card opened with three demonstrated live mutants, all green across the whole
|
||||
suite. Re-measured in round 2 against `release/1.0` @ `86eaef2`:
|
||||
|
||||
| mutation of `site_standing` | on release/1.0 @ 86eaef2 | closed by |
|
||||
|---|---|---|
|
||||
| `list(standing.values())[0]` — one unit's share | **SURVIVES**, full suite 21/21 green | part 9a + 9b (this card) |
|
||||
| `sum(...) / max(1, len(standing))` — the mean | **SURVIVES**, full suite 21/21 green | part 9a + 9b (this card) |
|
||||
| `max(standing.values(), key=abs)` — the largest share | **SURVIVES**, full suite 21/21 green | part 9a + 9b (this card) |
|
||||
|
||||
### ⚠️ ROUND 1 SAID `[0]` WAS ALREADY CLOSED BY SAFETY-32. THAT WAS FALSE.
|
||||
|
||||
Round 1 of this card recorded `[0]` as **CAUGHT by SAFETY-32's package-wide
|
||||
structural pin**, wrote that claim into four places, and told future authors
|
||||
*"DO NOT RE-COVER THAT ONE HERE"*. It is wrong, and **how** it went wrong is the
|
||||
part worth keeping.
|
||||
|
||||
**How the error was made.** The mutation was measured **once**. That single run
|
||||
happened to hit `test_peakguard.py`'s [[CI-06]] flake — a **measured ~20%**
|
||||
false-red rate — and the red was recorded as a **mutation kill**. Nothing else
|
||||
was checked, because a red is the answer you are hoping for and it did not look
|
||||
like it needed a second run.
|
||||
|
||||
**The correct measurement.** On `release/1.0` @ `86eaef2` carrying **only** the
|
||||
`[0]` edit (+4 bytes, re-read from disk, bytecode purged by
|
||||
`tools/mutation_run.sh`): the **full 21-file suite is green**, and
|
||||
`test_peakguard.py` run **five times in isolation** on that same mutated tree is
|
||||
**PASS PASS PASS PASS PASS**. The mutation **survives**. (The reviewer's own
|
||||
independent re-measurement of the same tree hit the flake once —
|
||||
PASS PASS PASS FAIL PASS — which is the same verdict plus a live demonstration
|
||||
of the mechanism that produced the original error.)
|
||||
|
||||
**Why SAFETY-32 cannot see it, read off 12j's own enumeration rather than
|
||||
argued.** Part 12j taints names *bound* to roster-carrying values and lists
|
||||
*accumulated* in a loop over one. `standing` is neither: it is a dict created
|
||||
empty at `main.py:1554` and filled by **subscript assignment**
|
||||
(`standing[inv.name] = stood`) inside the roster loop, and a subscript store is
|
||||
not a binding 12j follows. So `standing` never enters its taint set and
|
||||
`sum(standing.values())` is **not a roster site** at all. Run 12j against a tree
|
||||
carrying the `[0]` mutation and its enumeration lists `main.py:1553`, `1555` and
|
||||
`1690` — the three `self.inverters` sites bracketing this code — and **not
|
||||
`1599`**. No shape pin reaches this line; only the behavioural fixture below
|
||||
does.
|
||||
|
||||
**The rule this cost.** `test_peakguard.py` flakes at a measured ~20%. A single
|
||||
red from it proves nothing. Re-run it in isolation **at least five times** and
|
||||
**name the failing check** before believing any red from it. This card is the
|
||||
**third** measurement CI-06 has corrupted.
|
||||
|
||||
SAFETY-32's own disclosed blind spot says why the other two were always out of
|
||||
reach:
|
||||
|
||||
> *SEMANTICS. `min` → `max` → the mean are edits invisible to any shape pin,
|
||||
> permanently. Only the behavioural sets can see them.*
|
||||
|
||||
`sum` → mean and `sum` → `max(key=abs)` are **semantic**: identical shape,
|
||||
different meaning. **No shape pin will ever close them.** That disclosure was
|
||||
accurate, and is now confirmed by measurement rather than taken on trust.
|
||||
|
||||
`[0]` is the one that *looks* structural and therefore *looks* covered — and
|
||||
that appearance is exactly what produced the false attribution above. It is
|
||||
out of reach here for a different reason from the other two: not because the
|
||||
shape is invisible, but because **the value never becomes a roster** in the
|
||||
analysis's eyes. All three are closed by the same behavioural fixture, and
|
||||
**all three needed it.**
|
||||
|
||||
## 2. Why the suite could not see it — habit 4, inside the site half of the very card that names it
|
||||
|
||||
`test_watchdog.py`'s `_sign_site` is the **only** N≥2 site fixture in the
|
||||
repository. It runs at `site_sign_disagree_w: 320` with shares of roughly
|
||||
−2500 W **each**. Every one of them is individually far over the gate, so on
|
||||
those numbers
|
||||
|
||||
```
|
||||
sum = −5000 W over mean = −2500 W over max = −2500 W over
|
||||
```
|
||||
|
||||
— **all three reductions agree**, and a check whose two candidate answers happen
|
||||
to be equal cannot observe a change that swaps them. That is `MUTATION.md`'s
|
||||
third failure mode, and this is its ninth instance.
|
||||
|
||||
At a roster of **one** it is not a fixture defect but arithmetic:
|
||||
`sum == mean == max == the one share`, identically, so all three mutations are
|
||||
genuinely **equivalent** on a shipped install. No N=1 fixture can ever separate
|
||||
them; §3c asserts that rather than leaving it to the reader.
|
||||
|
||||
## 3. The fixture, and the numbers it is built on
|
||||
|
||||
Two **simulated** units rated 220 W and 280 W, both obeying exactly, inverted
|
||||
gain, house importing 2000 W. Both stand at their own rails, so `standing` is
|
||||
`{-220, -280}` in roster order and the meter reads +2500 W.
|
||||
|
||||
| reduction | value | vs the SHIPPED 300 W gate |
|
||||
|---|---|---|
|
||||
| `sum` | **−500 W** | **OVER** → trips |
|
||||
| `sum / len` (the mean) | −250 W | under → silent |
|
||||
| `max(…, key=abs)` | −280 W | under → silent |
|
||||
| `list(…)[0]` | −220 W | under → silent |
|
||||
|
||||
**Four distinct magnitudes — 500, 250, 280, 220 — of which exactly one clears
|
||||
the gate.** The asymmetry is load-bearing twice: equal shares would collapse
|
||||
mean, max and first onto one number, and putting the **smaller** unit first is
|
||||
what keeps `[0]` distinct from `max(key=abs)`. The gate is left at its shipped
|
||||
default so the fixture is graded against the magnitude an install runs; only the
|
||||
**hold** is shortened (325 s → 2 s), because the hold is a wall clock and the
|
||||
campaign behind 325 s is measured on the rig, not here.
|
||||
|
||||
⚠️ **220 W and 280 W are SIMULATED ratings chosen for that arithmetic and for
|
||||
nothing else.** They are not measurements. In particular they are **not**
|
||||
inverter B, which does not physically exist; B is a GW5048D-ES, serial
|
||||
`55048ESU22AW0992`, **4600 W from its datasheet** (`goodwe/NOTES.md` §1.1b).
|
||||
|
||||
### 3a. The site sign detector
|
||||
|
||||
Shipped tree: the site latches, commands 0 W on every inverter, and the sentence
|
||||
an operator reads is
|
||||
`SIGN_DISAGREEMENT: commanded -500 W against a meter reading +2500 W …`. No
|
||||
per-unit watchdog trips — every unit is faithfully executing its share, which is
|
||||
the asymmetry the site detector exists for.
|
||||
|
||||
Under the mean and under `max(key=abs)`: **nothing trips, ever.** The reviewer's
|
||||
tree was still commanding −500 W of charge into a +2500 W import at t = 595 s
|
||||
with `following=True`.
|
||||
|
||||
Two counterfactuals sit beside it so the trip is attributable:
|
||||
|
||||
* the **same** inverted-gain site whose shares sum to −250 W — under the gate —
|
||||
does **not** trip, so the trip above is the sum crossing 300 W and not the
|
||||
mere presence of a second inverter;
|
||||
* a site whose **device range is narrower than `max_w`** asks for −500 W while
|
||||
only −250 W stands, and does **not** trip — see §5.
|
||||
|
||||
### 3b. The second consumer, covered rather than scoped out
|
||||
|
||||
`site_standing` is also `looks_frozen()`'s `commanded_w`. The same
|
||||
discrimination applies at a different threshold: the site rail is
|
||||
`RAIL_FRAC * site_max_w` = 0.95 × 500 = **475 W**.
|
||||
|
||||
| reduction | value | vs the 475 W rail |
|
||||
|---|---|---|
|
||||
| `sum` | **500 W** | **RAILED** → `BLIND_FROZEN`, `floor_w = 0.0` |
|
||||
| the mean | 250 W | under → silent |
|
||||
| `max(…, key=abs)` | 280 W | under → silent |
|
||||
| `list(…)[0]` | 220 W | under → silent |
|
||||
|
||||
The sign is flipped from §3a on purpose: the gain is the **shipped positive**
|
||||
one and the frozen meter reads import, so the site *discharges* +500 W against a
|
||||
+2500 W import — the two agree in sign, SAFETY-30 has nothing to say, and this
|
||||
half grades SAFETY-18 alone. Reusing §3a's inverted gain would have the site
|
||||
sign latch park everything at 0 W, and the freeze conjunction could then never
|
||||
be true: a check measuring the *other* guard's remedy.
|
||||
|
||||
⚠️ **The open quarter is backfilled with the same stuck reading, and that is
|
||||
not decoration.** Without it the block is mostly uncovered, `blindness()`
|
||||
answers `BLIND_COVERAGE`, and the mutant reaches *the same action by a different
|
||||
route* — a check on the action alone could not then see the difference it names.
|
||||
Seeded, the measurement is honest:
|
||||
|
||||
* shipped: `blind = BLIND_FROZEN`, `floor_w = 0.0` — no charging while the
|
||||
billed quarter is unobservable;
|
||||
* both mutations: **not blind at all**, `floor_w = None` — the site may go on
|
||||
importing through a quarter whose billed average cannot be measured. That is
|
||||
the capacity-tariff hazard SAFETY-18 exists for, silently disarmed.
|
||||
|
||||
The counterfactual comes from the **same run**: on the earlier cycles the
|
||||
command had not yet reached the rail and the guard did not report SAFETY-18,
|
||||
with the meter equally frozen throughout — so the verdict is produced by the
|
||||
command magnitude `site_standing` carries and not by `unchanged_s` alone. A low
|
||||
gain (0.05, the schema floor) is what buys those below-the-rail cycles.
|
||||
|
||||
### 3c. At N=1, nothing changes — asserted
|
||||
|
||||
A real one-inverter controller is driven through the same frozen-meter
|
||||
scenario. Its `standing` has a single entry, so `sum`, the mean,
|
||||
`max(key=abs)` and `[0]` are printed and asserted to be **one number**; the
|
||||
site sign detector is still absent (part 7 counts the calls on the object); and
|
||||
SAFETY-18 still reaches `BLIND_FROZEN` on that same value. The claim "the
|
||||
shipped install is unaffected" now rests on the roster rather than on the
|
||||
reader.
|
||||
|
||||
## 4. Mutation ledger
|
||||
|
||||
Every run: a **fresh full-repo copy**, `__pycache__` and `*.pyc` excluded,
|
||||
mounted `:ro`, graded by `tools/mutation_run.sh` (which purges, prints the tree
|
||||
fingerprint, and verifies no cache appears during the run). The mutated line was
|
||||
**re-read from disk** after the edit and the byte delta printed. Shipped
|
||||
`app/main.py` is 234 542 bytes at `86eaef2`.
|
||||
|
||||
| # | mutation of `site_standing` | Δ bytes | verdict |
|
||||
|---|---|---|---|
|
||||
| M1 | `sum(...) / max(1, len(standing))` — the mean | +24 | **RED** |
|
||||
| M2 | `max(standing.values(), key=abs)` — largest share | +9 | **RED** |
|
||||
| M3 | `list(standing.values())[0]` — one share | +4 | **RED** — and **survives on release/1.0**, see §1 |
|
||||
| M4 | `min(standing.values(), key=abs)` — smallest share | +9 | **RED** |
|
||||
| M5 | `sum(abs(v) for v in ...)` — magnitude, sign lost | +16 | **RED** |
|
||||
| M6 | `-sum(standing.values())` — sign flipped | +1 | **RED** |
|
||||
| M7 | `float(self.target)` — the arbiter's site target | **−11** | **was a SURVIVOR — now RED**, see §5 |
|
||||
| M8 | `sum(standing.values()) / 2.0` | +6 | **RED** |
|
||||
| M9 | `sum(standing.values()) * 2.0` | +6 | **RED** |
|
||||
| M10 | `sorted(standing.values())[-1]` — largest signed | +7 | **RED** |
|
||||
| **M11** | **argument SWAP** at the call site: `evaluate(site_standing, self.grid, …)` → `evaluate(self.grid, site_standing, …)` (main.py:1620) | **0** | **was a SURVIVOR in round 1 — now RED**, see §4a |
|
||||
|
||||
**Every one of the ten is red in `test_watchdog.py`.** Re-measured in round 2
|
||||
on `release/1.0` @ `86eaef2` (where `app/main.py` is 234 542 bytes, 2 022 more
|
||||
than the `f72c48d` the round-1 figures were taken on): all ten still red, at the
|
||||
byte deltas in the table, each on a fresh copy with the edit re-read from disk.
|
||||
Before part 9 existed, **three** of these left the whole suite green — M1, M2
|
||||
**and M3** — and the remaining seven were caught by SAFETY-30's own N≥2 checks,
|
||||
none of which grade the *quantity*.
|
||||
|
||||
⚠️ **ONE FALSE RED, AND IT IS [[CI-06]]'s.** In the batch run M10 also reported
|
||||
`FAIL test_peakguard.py`. Re-run in isolation **three times** and once more
|
||||
through `tools/mutation_run.sh` — **four clean passes, zero failures**. The
|
||||
batch script had discarded the failure detail, so the failing check cannot be
|
||||
named here; what can be said is that the red did not reproduce in four attempts
|
||||
and that **no claim in this card rests on it**. `test_peakguard.py` is the file
|
||||
CI-06 records as flaky, and this is the behaviour it records. Believe no red
|
||||
from it without three isolated re-runs.
|
||||
|
||||
⚠️ **M3 IS NOT "FOR COMPLETENESS", AND ROUND 1 SAID IT WAS.** Round 1 recorded
|
||||
M3 as already closed structurally by SAFETY-32 and disclaimed it. §1 above has
|
||||
the correction and the mechanism: `[0]` **survives** a full green 21-file suite
|
||||
on `release/1.0` @ `86eaef2`, because `standing` is a dict filled by subscript
|
||||
assignment and never enters 12j's taint set. **M3 is a real kill by this card's
|
||||
fixture and by nothing else in the repository.** It is claimed here.
|
||||
|
||||
### 4a. ⚠️ The zero-byte survivor one line below the one this card pinned
|
||||
|
||||
Round 1 pinned the **value** `site_standing` and never pinned **where it goes**.
|
||||
Swapping the detector's first two arguments at `main.py:1620` is a **zero-byte**
|
||||
edit — the same characters, reordered — and it left the round-1 tree **21/21
|
||||
green**.
|
||||
|
||||
What it costs is the banner. `SignWatchdog.evaluate()` formats
|
||||
`commanded_w` first and `against_w` second, so under the swap part 9a's own
|
||||
output reads:
|
||||
|
||||
```
|
||||
SIGN_DISAGREEMENT: commanded +2500 W against a meter reading -500 W for 2 s …
|
||||
```
|
||||
|
||||
The site is standing at **−500 W of charge into a +2500 W import** and the
|
||||
**latching, site-stopping** banner tells the operator **the exact opposite** —
|
||||
which instrument read what, inverted. `watchdog.py:658-665` names this failure
|
||||
in its own words: *"a false statement about which instrument produced the
|
||||
evidence, on the one line somebody woken by this alarm reads first."*
|
||||
|
||||
**Why round 1's check could not see it, and this is the general lesson.** It
|
||||
asserted
|
||||
|
||||
```python
|
||||
f"{sum(_share38):.0f} W" in _c38.site_sign_wd.reason
|
||||
```
|
||||
|
||||
— that `"-500 W"` appears **somewhere** in the sentence. Under the swap it still
|
||||
does: in the **meter slot**. A substring test cannot reach a failure that is
|
||||
purely **positional**, and round 1's own comment claimed the opposite ("*would
|
||||
put a different number in the store, the action log and the banner, and this is
|
||||
where that shows*"). It shows the **number**, never its **position**. This is
|
||||
MUTATION.md's *"a check whose data cannot reach the failure it names"*, in the
|
||||
card that exists to complain about exactly that.
|
||||
|
||||
**The fix is one line and touches no `app/` code** — assert the **ordered
|
||||
pair**:
|
||||
|
||||
```python
|
||||
f"commanded {sum(_share38):+.0f} W against a meter reading "
|
||||
f"{_mid38['grid']:+.0f} W" in _c38.site_sign_wd.reason
|
||||
```
|
||||
|
||||
Measured: with that line, M11 is **red in `test_watchdog.py` and green in the
|
||||
other twenty files** — one file, one check.
|
||||
|
||||
### 4b. Claim wiring, re-measured rather than assumed
|
||||
|
||||
Round 1's reviewer disclosed it had **not** mutated the arbiter claim wiring or
|
||||
[[SAFETY-31]]/circulation. Both were mutated in round 2. Both are **zero-byte**
|
||||
edits to `arbiter.CLAIM_SCOPE`:
|
||||
|
||||
| # | mutation | Δ bytes | verdict |
|
||||
|---|---|---|---|
|
||||
| W1 | `"sign_site": SCOPE_SITE` → `SCOPE_UNIT` | **0** | **RED** — `test_watchdog.py` (parts 5 **and 9a**), `test_arbiter.py`, `test_peakguard.py` |
|
||||
| W2 | `"circulation": SCOPE_SITE` → `SCOPE_UNIT` | **0** | **RED** — `test_watchdog.py`, `test_arbiter.py`, `test_peakguard.py` |
|
||||
|
||||
Part 9a's *"…and it stops the WHOLE site, through the `sign_site` claim by name"*
|
||||
is one of the two checks that kills W1, so this card contributes to that
|
||||
coverage rather than merely inheriting it. **W2 is caught entirely by
|
||||
pre-existing checks** — SAFETY-38 adds nothing to circulation, and does not
|
||||
claim to.
|
||||
|
||||
## 5. The survivor this card went looking for, and closed
|
||||
|
||||
M7 is not one of the card's three. It was found by asking the question the
|
||||
recurring defect demands — *what mutation would my new checks NOT see?* — and it
|
||||
is the answer: **−11 bytes**, and it survived every check above **and the whole
|
||||
20-file suite**, because in every fixture built so far the arbiter's site target
|
||||
and the sum of what actually stands on the wire are **the same number**.
|
||||
|
||||
They are not the same number when a setpoint device's own reported range is
|
||||
narrower than its `max_w`. The `device` P_SAFETY claim is filed **per actuator**
|
||||
(`actuator_of("device", inv)`), so it bounds each unit's **share** and never the
|
||||
site target, and `clamp_to_rating()` clips again on the way out. On two units
|
||||
rated 220/280 W whose devices report ±120/±130 W, the site asks for **−500 W**
|
||||
and **−250 W** stands.
|
||||
|
||||
Which one the guards mean is already written down, in both of them: SAFETY-02
|
||||
grades *"the command standing on the wire"*, and `looks_frozen()`'s docstring
|
||||
says `commanded_w` is *"the EMITTED setpoint — what the arbiter resolved and
|
||||
`write_setpoint()` put on the wire — not the loop's raw wish"*. [[SAFETY-20]] is
|
||||
the whole card about the difference. Those sentences are now made to bite: on
|
||||
the site target the detector fires on a site standing at −250 W against a
|
||||
+2250 W meter — **under its own 300 W gate** — which is a latching, site-wide
|
||||
false trip on an install whose inverters simply report a narrower range than the
|
||||
operator typed.
|
||||
|
||||
## 6. Honest gaps
|
||||
|
||||
* **A mutation that changes the SIGN CONVENTION of `standing` itself** — i.e. in
|
||||
`main.py`'s `stood = inv.last_write if inv.last_write is not None else
|
||||
inv.target`, not on the reduction line — is **not** in this ledger. It is a
|
||||
different line and a different card; §3a's obedience precondition would see
|
||||
some of it, but that is not a measured claim and is not made here.
|
||||
* **The freeze half is graded at ONE roster length (2) and one rail.** The
|
||||
`RAIL_FRAC` constant, `rail_ceiling_w()`'s device-bound conjunction and
|
||||
`rail_unreachable()` are `test_freeze.py`'s subject and are untouched here.
|
||||
* **The site hold is 2 s, not the shipped 325 s.** The window's derivation is a
|
||||
rig campaign (`DECISIONS/SAFETY-30-per-unit-sign.md` §3B) and this file does
|
||||
not re-grade it. The **gate** is the shipped 300 W, which is the coordinate
|
||||
this card is about.
|
||||
* **Everything about inverter B here is simulated and labelled so.** No number
|
||||
in this document or in the fixture is a measurement of a device that does not
|
||||
yet exist.
|
||||
|
||||
### 6a. Round 2: what was closed, and what was NOT
|
||||
|
||||
Round 1's reviewer disclosed that it had not mutated SAFETY-31/circulation, the
|
||||
arbiter claim wiring, or ledger entries M4/M5/M6/M8/M9/M10. Enumerated, with the
|
||||
gaps left open stated rather than rounded off:
|
||||
|
||||
**Closed in round 2 (measured, on `86eaef2`, bytecode purged, edit re-read from
|
||||
disk, byte delta printed):**
|
||||
|
||||
1. **M11**, the zero-byte argument swap — §4a. Red on one named check.
|
||||
2. **M3**, the `[0]` reduction — re-measured, **survives on release/1.0**, closed
|
||||
by part 9a and 9b. The false attribution corrected in all four places it was
|
||||
committed: this file §1 and §4, `CHANGELOG.md`, and `test_watchdog.py`'s part
|
||||
9 header (which previously *instructed future authors not to re-cover it*).
|
||||
3. **M1, M2, M4, M5, M6, M7, M8, M9, M10** — every ledger entry re-run
|
||||
independently in round 2 rather than carried forward from round 1's report.
|
||||
All ten red; M1/M2/M4 re-run in the exact wrapped form the table records so
|
||||
the byte deltas are the table's own (+24/+9/+9).
|
||||
4. **W1**, `sign_site` claim scope — §4b. Zero bytes, red, part 9a among the
|
||||
killers.
|
||||
5. **W2**, `circulation` claim scope — §4b. Zero bytes, red, but **entirely on
|
||||
pre-existing checks**.
|
||||
|
||||
**NOT closed, and not claimed:**
|
||||
|
||||
* **SAFETY-31's `circ_wd` detector itself** — its threshold, its hold, its
|
||||
`circulating_w()` reduction over the roster. Only its **claim scope** was
|
||||
mutated (W2), and that kill belongs to checks this card did not write.
|
||||
Circulation's own behavioural coverage is `test_watchdog.py` part 4's and is
|
||||
untouched here.
|
||||
* **The other eight `CLAIM_SCOPE` entries** — `loop`, `peak`, `arbitrage`,
|
||||
`safety` (site) and `device`, `supervised`, `failsafe`, `maintenance` (unit).
|
||||
`CLAIM_SCOPE` has ten entries; only the two named above were mutated. `test_peakguard.py` part 10f grades the
|
||||
classification statically; that is a different instrument and this card did
|
||||
not re-measure it.
|
||||
* **`actuator_of()`'s own body** and the `n_units > 1` guard on the `sign_site`
|
||||
append at `main.py:1764` were **not** mutated.
|
||||
* **The ten ledger mutations were re-graded against `test_watchdog.py` only.**
|
||||
The "green in the other twenty files" half of the round-1 claim was
|
||||
re-verified on `86eaef2` for **M3** and **M11** (both full 21-file runs) and is
|
||||
otherwise carried forward from round 1's measurement on `f72c48d`. It is a
|
||||
weaker statement than round 1 made and is written down as such.
|
||||
* **`test_peakguard.py`'s CI-06 flake is not fixed by this card** and is not
|
||||
this card's subject. It is *characterised* here (five isolated runs on the M3
|
||||
tree, all PASS) only far enough to overturn the false kill it produced.
|
||||
@@ -135,12 +135,15 @@ manufactures them from a **fixture**: the check runs, the assertion is
|
||||
evaluated, the sentence above it is true — and the numbers it compares are
|
||||
arranged so that the failure it describes could not have changed the answer.
|
||||
|
||||
It is not hypothetical and it is not rare. EIGHT instances in two weeks; four
|
||||
It is not hypothetical and it is not rare. TEN instances in two weeks; four
|
||||
were found by review, two - CFG-04's fixture pair - by an author's own mutation
|
||||
battery, which is the cheaper place, one by review again, in the one
|
||||
place nobody had thought to point the rule at: not a check in the suite, but a
|
||||
COMMITTED EVIDENCE ARTIFACT four documents cite - and the eighth INSIDE THE FIX
|
||||
WRITTEN TO CLOSE THE SEVENTH.
|
||||
COMMITTED EVIDENCE ARTIFACT four documents cite - the eighth INSIDE THE FIX
|
||||
WRITTEN TO CLOSE THE SEVENTH, the ninth inside the SITE HALF of the card
|
||||
that names the rule in its own text - and the TENTH INSIDE THE FIX WRITTEN TO
|
||||
CLOSE THE NINTH, for the second time in this list. See SAFETY-38 below: the
|
||||
check that closed it asserted a NUMBER and not the number's POSITION.
|
||||
|
||||
⚠️ **AND IT HAS NOW APPEARED IN SIX CONSECUTIVE CARDS.** The seventh instance,
|
||||
MAINT-05's, is the one that says why: the defect is not carelessness about
|
||||
@@ -234,6 +237,47 @@ same place twice, the check is decoration.
|
||||
assertion cannot fail is exactly the thing this section is about. Two habits
|
||||
follow, and both are habit 5 and 6 below.
|
||||
|
||||
* **SAFETY-38** — `main.py`'s
|
||||
`site_standing = float(sum(standing.values()))`, the first argument of
|
||||
SAFETY-30's latching site sign detector *and* SAFETY-18's `looks_frozen()`
|
||||
input. `test_watchdog.py`'s `_sign_site` is the suite's **only** N≥2 site
|
||||
fixture, and it runs shares of about **−2500 W each** — every one
|
||||
individually over the 320 W gate it is configured with. On numbers like those
|
||||
`sum`, the mean and `max(key=abs)` **all agree**, so the reduction could be
|
||||
swapped for either of the other two and the site guard went **blind with the
|
||||
whole suite green** — still commanding −500 W of charge into a +2500 W import at
|
||||
t = 595 s with `following=True`. At a roster of **one** it is worse and it is
|
||||
not a fixture defect at all: `sum == mean == max == the one share`
|
||||
*identically*, so every such mutation is genuinely **equivalent** there and no
|
||||
N=1 fixture could ever separate them. The fixture that separates them is the
|
||||
one the detector exists for — **per-unit shares EACH BELOW the gate whose SUM
|
||||
clears it** — and it is now `test_watchdog.py` part 9, at asymmetric ratings
|
||||
so that all four candidate reductions give four **distinct** answers.
|
||||
|
||||
⚠️ **AND THE CARD'S OWN SEARCH FOR ITS NEXT SURVIVOR FOUND ONE, WHICH IS THE
|
||||
POINT OF ASKING.** Having built the fixture, the question *what mutation would
|
||||
this NOT see?* produced `float(self.target)` — the arbiter's site target
|
||||
instead of the sum of what stands on the wire — at **−11 B**, green across the
|
||||
whole suite, because every fixture in the repository was built where the two
|
||||
are the same number. They separate only when a device's reported range is
|
||||
narrower than its `max_w`, since the `device` claim is filed **per actuator**
|
||||
and never bounds the site target. Closed in the same commit, by a
|
||||
counterfactual that asks for −500 W while −250 W stands.
|
||||
|
||||
⚠️ **AND THEN THE FIX ITSELF WAS THE TENTH INSTANCE — A SUBSTRING WHERE THE
|
||||
FAILURE WAS POSITIONAL.** The check written to pin the banner asserted
|
||||
`f"{sum(...):.0f} W" in reason`: that **"−500 W" appears somewhere** in the
|
||||
sentence. Swapping the detector's first two arguments
|
||||
(`evaluate(site_standing, self.grid, …)` → `evaluate(self.grid, site_standing, …)`)
|
||||
is a **ZERO-BYTE** edit that leaves both numbers in the string and moves each
|
||||
into the other's slot — so the substring is still found, **in the meter
|
||||
slot**, and the whole suite stayed green while the latching site-stopping
|
||||
banner told the operator which instrument read what **exactly backwards**.
|
||||
The fix is to assert the **ORDERED PAIR**,
|
||||
`f"commanded {sum:+.0f} W against a meter reading {grid:+.0f} W"`.
|
||||
|
||||
The general habit is **14** below.
|
||||
|
||||
Note what these have in common with a masked rung: the mutation *runs*, and the
|
||||
suite is *honestly* green. Nothing in a purge, a fingerprint or a disassembly
|
||||
can see it, because the code under test really did behave identically on the
|
||||
@@ -363,6 +407,26 @@ Cheap habits fall out of it, and all of them are now used in this repository:
|
||||
completeness a reviewer falsifies in ten minutes**, and every round of this
|
||||
card that claimed the latter was rejected for it.
|
||||
|
||||
14. **An `in` test against a formatted sentence grades PRESENCE, never
|
||||
ARRANGEMENT — so assert the ORDERED PAIR.** SAFETY-38 pinned the banner of a
|
||||
latching, site-stopping alarm with
|
||||
`f"{sum(_share38):.0f} W" in ...reason` — that `"-500 W"` appears
|
||||
*somewhere*. Swapping the detector's first two arguments at the call site
|
||||
(`evaluate(site_standing, self.grid, …)` →
|
||||
`evaluate(self.grid, site_standing, …)`) is a **ZERO-BYTE** edit: both
|
||||
numbers are still in the string, each in the other's slot. The substring was
|
||||
still found — **in the meter slot** — the whole suite stayed green, and the
|
||||
banner told the operator which instrument read what **exactly backwards**.
|
||||
Whenever the property you mean is "**this** value went in **this** slot" — a
|
||||
reason string, a log line, a notification, an MQTT payload — assert the
|
||||
surrounding **literal text with the value embedded in its own position**
|
||||
(`f"commanded {x:+.0f} W against a meter reading {y:+.0f} W"`), or assert
|
||||
the fields **before** they are formatted. Two values that both appear in one
|
||||
sentence can always be transposed by an edit that costs **nothing**, and
|
||||
that no byte delta, no fingerprint and no shape pin can see. ⚠️ Note where
|
||||
this one was found: **inside the fix written to close the previous instance
|
||||
of the same family**, which is the second time in this list.
|
||||
|
||||
And the mutation-table consequence: **a variant is not covered because a
|
||||
near-miss of it is.** DEV-02's table listed the *actuator* variant of the
|
||||
per-unit claim defect (`device`/`supervised` filed without `inv`), which the
|
||||
|
||||
@@ -1993,6 +1993,564 @@ check("...and the counterfactual again: the same site with nothing latched "
|
||||
not _bn_n["banner"].startswith("FAILSAFE")
|
||||
and _bn_n["banner"] != _bn_b["banner"])
|
||||
|
||||
|
||||
print()
|
||||
print("9. SAFETY-38: `site_standing` - the ONE quantity BOTH site guards are")
|
||||
print(" asked about - pinned by shares that CANNOT answer for it")
|
||||
# ⚠️ WHAT THIS SECTION PINS, AND WHY NOTHING ABOVE IT COULD.
|
||||
# `main.py`'s `site_standing = float(sum(standing.values()))` is the first
|
||||
# argument of SAFETY-30's site sign detector AND the `commanded_w` handed to
|
||||
# SAFETY-18's `looks_frozen()`. It was pinned by NOTHING. THREE mutations of it
|
||||
# were demonstrated live against a full green suite, and ALL THREE ARE COVERED
|
||||
# HERE:
|
||||
#
|
||||
# sum(...) / max(1, len(standing)) the MEAN
|
||||
# max(standing.values(), key=abs) the LARGEST SHARE
|
||||
# list(standing.values())[0] the FIRST SHARE
|
||||
#
|
||||
# ⚠️ ROUND 1 OF THIS CARD SAID THE THIRD ONE WAS ALREADY CLOSED BY SAFETY-32's
|
||||
# PACKAGE-WIDE STRUCTURAL PIN AND TOLD FUTURE AUTHORS "DO NOT RE-COVER THAT ONE
|
||||
# HERE". THAT WAS FALSE, AND HOW IT BECAME FALSE IS THE USEFUL PART. It was
|
||||
# measured ONCE; that single run happened to hit test_peakguard.py's ~20%
|
||||
# CI-06 flake, the red was recorded as a mutation KILL, and the claim was then
|
||||
# written into four places. RE-MEASURED IN ROUND 2, on release/1.0 @ 86eaef2
|
||||
# carrying ONLY the `[0]` edit (+4 bytes, re-read from disk): the full suite is
|
||||
# 21/21 GREEN, and test_peakguard.py run FIVE times in isolation on that same
|
||||
# mutated tree is PASS PASS PASS PASS PASS. The mutation SURVIVES. (The
|
||||
# reviewer's own independent re-measurement of the same tree caught the flake
|
||||
# once - PASS PASS PASS FAIL PASS - which is the same verdict: a survivor, plus
|
||||
# a demonstration of the flake that produced the original error.) A SINGLE RED
|
||||
# FROM test_peakguard.py PROVES NOTHING - re-run it at least five times and NAME
|
||||
# the failing check before believing it. That rule is CI-06's, and this card is
|
||||
# the third measurement it has corrupted.
|
||||
#
|
||||
# THE MECHANISM, confirmed by reading 12j's own enumeration rather than by
|
||||
# argument. SAFETY-32's part 12j taints names BOUND to roster-carrying values
|
||||
# and lists ACCUMULATED in a loop over one. `standing` is neither: it is a dict
|
||||
# created empty at main.py:1554 and filled by SUBSCRIPT assignment
|
||||
# (`standing[inv.name] = stood`) inside the roster loop, and a subscript store
|
||||
# is not a binding 12j follows. So `standing` never enters its taint set at all,
|
||||
# and `sum(standing.values())` is not a roster site. Run 12j on a tree carrying
|
||||
# the `[0]` mutation and it enumerates main.py:1553, 1555 and 1690 - the three
|
||||
# `self.inverters` sites around this code - and NOT 1599. A structural pin
|
||||
# cannot see this line. Only the behavioural fixture below can.
|
||||
#
|
||||
# Identical shape, different meaning - which is precisely the blind spot
|
||||
# SAFETY-32 disclosed in its own words ("SEMANTICS. `min` -> `max` -> the mean
|
||||
# are edits invisible to any shape pin, permanently"). No shape pin will ever
|
||||
# close them. Only a behavioural fixture can, and this is it.
|
||||
#
|
||||
# ⚠️ WHY PART 5 ABOVE CANNOT SEE THEM, AND IT IS THIS REPOSITORY'S RECURRING
|
||||
# DEFECT INSIDE THE SITE HALF OF THE VERY CARD THAT NAMES IT. `_sign_site` is
|
||||
# the only N>=2 site fixture in the suite and it runs at
|
||||
# `site_sign_disagree_w: 320` with shares of about -2500 W EACH - every one of
|
||||
# them individually far OVER the gate. On values like those the sum, the mean
|
||||
# and the largest share all clear it, so all three reductions agree, and a
|
||||
# check whose two candidate answers happen to be EQUAL cannot observe a change
|
||||
# that swaps them. MUTATION.md habit 4. At a roster of ONE it is worse: there
|
||||
# `sum == mean == max == the one share` identically, so every mutation is
|
||||
# EQUIVALENT there - see 9c, where that identity is asserted rather than
|
||||
# assumed.
|
||||
#
|
||||
# ⚠️ SO THE NUMBERS BELOW ARE CHOSEN TO DISCRIMINATE, AND HERE IS THE
|
||||
# ARITHMETIC THEY ARE CHOSEN FOR. Two simulated units rated 220 W and 280 W
|
||||
# stand at their own rails, so `standing` is {-220, -280} in roster order:
|
||||
#
|
||||
# sum -500 W |500| > 300 OVER the gate -> TRIPS
|
||||
# mean -250 W |250| < 300 under it -> silent
|
||||
# max(..., key=abs) -280 W |280| < 300 under it -> silent
|
||||
# list(...)[0] -220 W |220| < 300 under it -> silent
|
||||
#
|
||||
# FOUR DISTINCT MAGNITUDES - 500, 250, 280, 220 - of which exactly ONE clears
|
||||
# the SHIPPED 300 W gate. The asymmetry is load-bearing twice over: equal
|
||||
# shares would collapse mean, max and first onto one number and the fixture
|
||||
# could not tell them apart, and putting the SMALLER unit first is what keeps
|
||||
# `[0]` distinct from `max(key=abs)`.
|
||||
#
|
||||
# ⚠️ THE RATINGS ARE SIMULATED AND ARE NOT ANY REAL INVERTER'S. 220 W and 280 W
|
||||
# are chosen for the arithmetic in that table and for nothing else. In
|
||||
# particular they are NOT inverter B, which does not physically exist; B's
|
||||
# rating is 4600 W FROM ITS DATASHEET (goodwe/NOTES.md 1.1b) and no number in
|
||||
# this section is a measurement of anything.
|
||||
#
|
||||
# ⚠️ THE GATE IS THE SHIPPED ONE AND THE HOLD IS NOT. `site_sign_disagree_w` is
|
||||
# left at its default so this fixture is graded against the magnitude an
|
||||
# install actually runs; `site_sign_disagree_s` is shortened from 325 s to 2 s
|
||||
# because the hold is a wall clock and the campaign behind 325 s is measured on
|
||||
# the rig, not here. The gate is the coordinate this section is about.
|
||||
from app import peakguard as _pg38 # noqa: E402
|
||||
from app.freeze import rail_w as _rail_w38 # noqa: E402
|
||||
from app.p1 import P1Sample as _P1Sample38 # noqa: E402
|
||||
import time as _time38 # noqa: E402
|
||||
|
||||
_S38_A_W, _S38_B_W = 220.0, 280.0 # SIMULATED. See the note above.
|
||||
_S38_LOAD_W = 2000.0
|
||||
_S38_FROZEN_METER_W = 2500.0
|
||||
|
||||
|
||||
def _s38_roster(*ratings):
|
||||
"""A CFG-04 `inverters:` roster, which is the shape an N>=2 install runs.
|
||||
|
||||
⚠️ NOT `_sign_site`'s "build one from the flat keys and append a second".
|
||||
`Controller.__init__` builds `Tuning` FROM the roster - `max_w=site_max_w` -
|
||||
so a unit appended afterwards leaves the site loop bounded at ONE unit's
|
||||
rating. That is harmless where part 3 uses it and fatal here: the whole
|
||||
fixture is a site command standing at the ROSTER's rail.
|
||||
"""
|
||||
return [{"name": name, "setpoint_entity": f"number.sp_{tag}",
|
||||
"soc_entity": f"sensor.soc_{tag}", "batt_entity": f"sensor.batt_{tag}",
|
||||
"max_w": w, "bms_soc_floor": 10}
|
||||
for name, tag, w in zip(("inverter-a", "inverter-b", "inverter-c"),
|
||||
("a", "b", "c"), ratings)]
|
||||
|
||||
|
||||
class _S38Plant:
|
||||
"""Units that obey INSTANTLY and a meter that is `load - sum(measured)`.
|
||||
|
||||
The same modelling choice part 3 makes and for the same reason: an instant
|
||||
plant removes the one mechanism that could make an obedient unit look
|
||||
disobedient, so what remains to be graded is the ATTRIBUTION.
|
||||
"""
|
||||
|
||||
def __init__(self, load_w=_S38_LOAD_W):
|
||||
self.load_w = float(load_w)
|
||||
self.writes = []
|
||||
self.calls = []
|
||||
self.ctrl = None
|
||||
|
||||
async def call(self, domain, service, data):
|
||||
self.calls.append((domain, service, data))
|
||||
|
||||
async def limits(self, entity):
|
||||
return None
|
||||
|
||||
def measured(self):
|
||||
if self.ctrl is None:
|
||||
return []
|
||||
return [float((i.last_write if i.last_write is not None else i.target) or 0.0)
|
||||
for i in self.ctrl.inverters]
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
m = self.measured()
|
||||
if entity == "sensor.grid":
|
||||
return self.load_w - sum(m)
|
||||
for i, tag in enumerate(("a", "b", "c")):
|
||||
if entity == f"sensor.soc_{tag}":
|
||||
return 50.0
|
||||
if entity == f"sensor.batt_{tag}":
|
||||
return m[i] if i < len(m) else None
|
||||
return None
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append((entity, float(value)))
|
||||
return True
|
||||
|
||||
|
||||
def _s38_ctrl(hass, ratings, store=None, **over):
|
||||
opts = {"meter_entity": "sensor.grid", "meter_source": "off",
|
||||
"inverters": _s38_roster(*ratings),
|
||||
"gain": -0.6,
|
||||
# The per-unit pair, distinct from the site pair in BOTH
|
||||
# coordinates, for part 3's reason: an equality below must be able
|
||||
# to fail on the magnitude alone or on the hold alone.
|
||||
"unit_sign_disagree_w": 250, "unit_sign_disagree_s": 1,
|
||||
# ⚠️ `site_sign_disagree_w` DELIBERATELY ABSENT - the shipped 300 W
|
||||
# default is the gate this whole section is graded against.
|
||||
"site_sign_disagree_s": 2,
|
||||
# SAFETY-31 is given a long window so the SITE is not stopped by
|
||||
# circulation while this section grades the sign attribution. It is
|
||||
# isolation, not a claim that SAFETY-31 is silent here.
|
||||
"circulation_hold_s": 3600, "auto_start": True}
|
||||
opts.update(over)
|
||||
c = Controller(opts, hass, store if store is not None else _MemStore(),
|
||||
_P(), stop=asyncio.Event())
|
||||
for inv in c.inverters:
|
||||
inv.dev_min, inv.dev_max = -inv.max_w, inv.max_w
|
||||
c.auto = True
|
||||
hass.ctrl = c
|
||||
return c
|
||||
|
||||
|
||||
def _s38_stood(c):
|
||||
return [inv.last_write if inv.last_write is not None else inv.target
|
||||
for inv in c.inverters]
|
||||
|
||||
|
||||
print()
|
||||
print("9a. the SITE sign detector: per-unit shares EACH BELOW the gate whose")
|
||||
print(" SUM clears it - the case the site detector exists for")
|
||||
|
||||
|
||||
async def _s38_site():
|
||||
hass = _S38Plant()
|
||||
c = _s38_ctrl(hass, (_S38_A_W, _S38_B_W))
|
||||
seen = []
|
||||
for _ in range(20):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
seen.append(dict(grid=c.grid, stood=_s38_stood(c),
|
||||
meas=[i.batt for i in c.inverters],
|
||||
site=c.site_sign_wd.tripped,
|
||||
units=[i.sign_wd.tripped for i in c.inverters],
|
||||
following=c.following))
|
||||
await asyncio.sleep(0.2)
|
||||
return c, seen
|
||||
|
||||
|
||||
_c38, _s38seen = asyncio.run(_s38_site())
|
||||
# The last sample BEFORE the trip, named rather than indexed - part 5's lesson.
|
||||
# After the trip every command is 0 W, so a fixed index reads the REMEDY.
|
||||
_pre38 = [x for x in _s38seen if not x["site"]]
|
||||
_mid38 = _pre38[-1]
|
||||
_GATE38 = _c38.site_sign_wd.cfg.min_w
|
||||
_share38 = list(_mid38["stood"])
|
||||
_red38 = {"sum": sum(_share38),
|
||||
"mean": sum(_share38) / max(1, len(_share38)),
|
||||
"max(key=abs)": max(_share38, key=abs),
|
||||
"[0]": _share38[0]}
|
||||
print(f" last cycle before the trip: stood "
|
||||
f"{[round(x) for x in _share38]} measured "
|
||||
f"{[round(x) for x in _mid38['meas']]} meter {_mid38['grid']:+.0f} W")
|
||||
print(f" site gate {_GATE38:.0f} W (SHIPPED default), hold "
|
||||
f"{_c38.site_sign_wd.cfg.hold_s:.0f} s")
|
||||
for _k, _v in _red38.items():
|
||||
print(f" {_k:>13} = {_v:+7.1f} W "
|
||||
f"{'OVER' if abs(_v) > _GATE38 else 'under'} the gate")
|
||||
check("PRECONDITION: the gate really is the SHIPPED 300 W, so this fixture is "
|
||||
"graded against the magnitude an install runs and not against a number "
|
||||
"chosen to make it pass",
|
||||
_GATE38 == float(SIGN_OPTION_DEFAULTS["site_sign_disagree_w"]) == 300.0)
|
||||
check("⚠️ PRECONDITION, AND IT IS THE WHOLE OF SAFETY-38. EVERY per-unit share "
|
||||
"is BELOW the site gate and their SUM is OVER it. `_sign_site` above "
|
||||
"cannot make this statement - its shares are each individually over the "
|
||||
"gate, so sum, mean and largest-share all agree there and its values "
|
||||
"cannot observe a change that swaps them",
|
||||
len(_share38) >= 2
|
||||
and all(abs(s) < _GATE38 for s in _share38)
|
||||
and abs(sum(_share38)) > _GATE38)
|
||||
check("...and the FOUR candidate reductions give FOUR DISTINCT answers on it, "
|
||||
"of which exactly ONE clears the gate. That is what makes this fixture "
|
||||
"able to tell `sum` from the mean, from the largest share and from the "
|
||||
"first share - and it is the property the existing site fixture lacks",
|
||||
len({round(v, 6) for v in _red38.values()}) == 4
|
||||
and [k for k, v in _red38.items() if abs(v) > _GATE38] == ["sum"])
|
||||
check("PRECONDITION: EVERY inverter is obeying - each unit's measured power "
|
||||
"agrees in sign with its own share - and the site is charging into an "
|
||||
"importing house. Without this the trip below could be a per-unit fault "
|
||||
"in disguise rather than the site fault this grades",
|
||||
all(s * m > 0 for s, m in zip(_mid38["stood"], _mid38["meas"]))
|
||||
and sum(_mid38["stood"]) * _mid38["grid"] < 0
|
||||
and _mid38["following"] is True)
|
||||
check("⚠️ THE SITE WATCHDOG TRIPS ON THE SUM, and no per-unit watchdog does. "
|
||||
"Under ALL THREE semantic mutations - `sum -> mean`, "
|
||||
"`sum -> max(key=abs)` AND `sum -> list(...)[0]` - NOTHING trips, ever: "
|
||||
"the reviewer's tree was still commanding -500 W of charge into a "
|
||||
"+2500 W import at t = 595 s with following=True. This is the check all "
|
||||
"three go red on. `[0]` is here BECAUSE IT IS NOT COVERED ELSEWHERE - "
|
||||
"see the section header for the mis-measurement that said it was",
|
||||
_c38.site_sign_wd.tripped
|
||||
and not any(i.sign_wd.tripped for i in _c38.inverters))
|
||||
print(f" {_c38.site_sign_wd.reason!r}")
|
||||
check("⚠️ ...and the sentence an operator reads carries THE SUM IN THE "
|
||||
"COMMANDED SLOT AND THE METER IN THE METER SLOT - the ORDERED PAIR, not "
|
||||
"two numbers loose in a sentence. ROUND 1 ASSERTED `f'{sum(...):.0f} W' "
|
||||
"in reason`, i.e. that '-500 W' appears SOMEWHERE, AND THAT WAS A HOLE "
|
||||
"ONE LINE WIDE. Swapping the detector's first two arguments - "
|
||||
"`evaluate(site_standing, self.grid, ...)` -> "
|
||||
"`evaluate(self.grid, site_standing, ...)`, a ZERO-BYTE edit at "
|
||||
"main.py:1620 - leaves BOTH numbers in the string and moves each into "
|
||||
"the other's slot, so the substring test still passed and the whole "
|
||||
"suite stayed green. The swapped banner reads 'commanded +2500 W "
|
||||
"against a meter reading -500 W': the site is standing at -500 W of "
|
||||
"charge INTO a +2500 W import and the latching, site-stopping banner "
|
||||
"tells the operator the exact opposite, on the one line somebody woken "
|
||||
"by this alarm reads first. watchdog.py:658-665 calls naming the wrong "
|
||||
"instrument there 'a false statement about which instrument produced "
|
||||
"the evidence'. A check whose data cannot reach the failure it names is "
|
||||
"MUTATION.md's own defect; this is the line that closes it",
|
||||
f"commanded {sum(_share38):+.0f} W against a meter reading "
|
||||
f"{_mid38['grid']:+.0f} W" in _c38.site_sign_wd.reason)
|
||||
check("...and it stops the WHOLE site, through the `sign_site` claim by name "
|
||||
"rather than by some other guard happening to stop it",
|
||||
_c38.target == 0.0 and "sign_site" in _c38.reason
|
||||
and all(i.target == 0.0 for i in _c38.inverters)
|
||||
and _c38.store.data.get("site_sign_tripped") is True)
|
||||
# ⚠️ THE COUNTERFACTUAL, and it is what says the check above is produced by the
|
||||
# SUM crossing the gate rather than by two inverters being present. Same plant,
|
||||
# same roster shape, same everything - except the units are rated so that the
|
||||
# sum lands UNDER the gate. Nothing may trip.
|
||||
_S38_SMALL = (120.0, 130.0) # sum 250 W: under the 300 W gate
|
||||
|
||||
|
||||
async def _s38_under():
|
||||
hass = _S38Plant()
|
||||
c = _s38_ctrl(hass, _S38_SMALL)
|
||||
for _ in range(20):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
await asyncio.sleep(0.2)
|
||||
return c
|
||||
|
||||
|
||||
_c38u = asyncio.run(_s38_under())
|
||||
print(f" counterfactual: stood {[round(x) for x in _s38_stood(_c38u)]} "
|
||||
f"sum {sum(_s38_stood(_c38u)):+.0f} W meter {_c38u.grid:+.0f} W")
|
||||
check("...and the counterfactual: the SAME inverted-gain site whose shares sum "
|
||||
"to 250 W - under the gate - does NOT trip, over the same 20 cycles. So "
|
||||
"the trip above is the sum crossing 300 W and not the mere presence of a "
|
||||
"second inverter",
|
||||
abs(sum(_s38_stood(_c38u))) < _GATE38
|
||||
and not _c38u.site_sign_wd.tripped
|
||||
and not any(i.sign_wd.tripped for i in _c38u.inverters))
|
||||
# ⚠️ AND A SECOND COUNTERFACTUAL, WHICH EXISTS BECAUSE OF A MUTATION THE CHECKS
|
||||
# ABOVE COULD NOT SEE AND THIS SEARCH WENT LOOKING FOR.
|
||||
# `site_standing = float(self.target)` - the arbiter's SITE TARGET instead of
|
||||
# the sum of what actually stands on the wire - is -11 bytes, and it survived
|
||||
# every check above AND the whole 20-file suite, because in every fixture so
|
||||
# far the two are the same number. THEY ARE NOT THE SAME NUMBER when a setpoint
|
||||
# device's own reported range is narrower than its `max_w`: the `device`
|
||||
# P_SAFETY claim is filed PER ACTUATOR (main.py, `actuator_of("device", inv)`),
|
||||
# so it bounds each unit's SHARE and never the site target, and
|
||||
# `clamp_to_rating()` clips again on the way out. Here the site asks for -500 W
|
||||
# and -250 W stands.
|
||||
#
|
||||
# WHICH ONE THE GUARDS MEAN IS ALREADY WRITTEN DOWN, IN BOTH OF THEM: SAFETY-02
|
||||
# grades "the command standing on the wire", and `looks_frozen()`'s docstring
|
||||
# says `commanded_w` is "the EMITTED setpoint - what the arbiter resolved and
|
||||
# `write_setpoint()` put on the wire - not the loop's raw wish". SAFETY-20 is
|
||||
# the whole card about the difference. This check is those sentences made to
|
||||
# bite: on the site target the detector fires on a site that is standing at
|
||||
# -250 W against a +2250 W meter - under its own 300 W gate - which is a
|
||||
# LATCHING, site-stopping false trip on an install whose inverters simply
|
||||
# report a narrower range than the operator typed.
|
||||
_S38_DEV = (120.0, 130.0) # narrower than the 220/280 W ratings
|
||||
|
||||
|
||||
async def _s38_devclamped():
|
||||
hass = _S38Plant()
|
||||
c = _s38_ctrl(hass, (_S38_A_W, _S38_B_W))
|
||||
for inv, d in zip(c.inverters, _S38_DEV):
|
||||
inv.dev_min, inv.dev_max = -d, d
|
||||
for _ in range(20):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
await asyncio.sleep(0.2)
|
||||
return c
|
||||
|
||||
|
||||
_c38d = asyncio.run(_s38_devclamped())
|
||||
_stood38d = _s38_stood(_c38d)
|
||||
print(f" device-clamped: site target {_c38d.target:+.0f} W but only "
|
||||
f"{[round(x) for x in _stood38d]} = {sum(_stood38d):+.0f} W stands, "
|
||||
f"meter {_c38d.grid:+.0f} W")
|
||||
check("PRECONDITION: the site TARGET and the EMITTED total are DIFFERENT "
|
||||
"numbers here, on opposite sides of the gate - -500 W asked, -250 W "
|
||||
"standing. Without that separation this check and the one above compare "
|
||||
"two values that happen to be equal, which is the defect this card is "
|
||||
"the sixth instance of",
|
||||
abs(_c38d.target) > _GATE38 and abs(sum(_stood38d)) < _GATE38)
|
||||
check("⚠️ ...and NOTHING TRIPS, because the quantity graded is what STANDS ON "
|
||||
"THE WIRE and not what the arbiter asked for. `float(self.target)` is "
|
||||
"-11 bytes, survives the other 20 files, and turns this ordinary "
|
||||
"narrow-rating install into a latching site-wide false trip",
|
||||
not _c38d.site_sign_wd.tripped
|
||||
and not any(i.sign_wd.tripped for i in _c38d.inverters)
|
||||
and _c38d.target != 0.0)
|
||||
|
||||
|
||||
print()
|
||||
print("9b. THE SECOND CONSUMER: the same value is SAFETY-18's `commanded_w`")
|
||||
print(" inside `looks_frozen()`, and both mutations blind it too")
|
||||
# ⚠️ THIS IS THE AC THE CARD REFUSES TO LET BE SCOPED OUT SILENTLY.
|
||||
# `site_standing` is handed to `looks_frozen()` at main.py's `peakguard.decide(
|
||||
# ..., frozen=...)` call, where it is the EMITTED command graded against the
|
||||
# site rail. Both surviving mutations shrink it there too, and nothing went red.
|
||||
#
|
||||
# THE RAIL ARITHMETIC, and it is the same discrimination as 9a at a different
|
||||
# threshold: the site rail is `RAIL_FRAC * site_max_w` = 0.95 * 500 = 475 W.
|
||||
#
|
||||
# sum 500 W >= 475 RAILED -> BLIND_FROZEN, floor 0 W
|
||||
# mean 250 W < 475 silent
|
||||
# max(..., key=abs) 280 W < 475 silent
|
||||
# list(...)[0] 220 W < 475 silent
|
||||
#
|
||||
# ⚠️ THE SIGN IS FLIPPED FROM 9a ON PURPOSE. Here the gain is the SHIPPED
|
||||
# POSITIVE one and the frozen meter reads IMPORT, so the site discharges +500 W
|
||||
# against a +2500 W import - the two agree in sign, SAFETY-30 has nothing to
|
||||
# say, and this section grades SAFETY-18 alone. Reusing 9a's inverted gain
|
||||
# would have the site sign latch park everything at 0 W and the freeze
|
||||
# conjunction could then never be true: a check measuring the other guard's
|
||||
# remedy.
|
||||
#
|
||||
# WHAT THE MUTATIONS COST HERE, measured rather than asserted: on the shipped
|
||||
# tree the guard goes blind and files `floor_w = 0.0` - "the battery may not
|
||||
# import while the billed quarter cannot be measured". Under both mutations it
|
||||
# is NOT BLIND AT ALL and files `floor_w = None`, so the site may go on
|
||||
# charging through a quarter whose billed average is unobservable. That is the
|
||||
# capacity-tariff hazard SAFETY-18 exists for, silently disarmed.
|
||||
|
||||
|
||||
class _S38Src:
|
||||
"""The transport's own `unchanged_s`, which only homewizard_local has."""
|
||||
|
||||
def __init__(self, unchanged_s):
|
||||
self.unchanged_s = float(unchanged_s)
|
||||
|
||||
|
||||
def _s38_feed(c, w, ts=None, mono=None):
|
||||
now = ts if ts is not None else datetime.now(timezone.utc)
|
||||
c.p1.submit(_P1Sample38(
|
||||
ingest_ts=now,
|
||||
ingest_mono=mono if mono is not None else _time38.monotonic(),
|
||||
telegram_ts=now, source="homewizard_local",
|
||||
import_w=max(w, 0.0), export_w=max(-w, 0.0), net_w=w,
|
||||
per_phase_w=(w,), per_phase_import_w=(max(w, 0.0),)))
|
||||
|
||||
|
||||
def _s38_seed_quarter(c, w):
|
||||
"""Backfill the OPEN quarter with the same stuck value, at 10 s spacing.
|
||||
|
||||
⚠️ THIS IS NOT DECORATION. Without it the open block is mostly uncovered and
|
||||
`blindness()` answers BLIND_COVERAGE - which is still blind, still floor
|
||||
0 W, and would therefore MASK the mutations: the mutant would reach the
|
||||
same action by a different route and a check on the action alone could not
|
||||
see the difference it names. Seeded, the mutant is not blind at ALL, which
|
||||
is the honest measurement of what the mutation costs. A meter that has been
|
||||
stuck at the same reading all quarter is also what SAFETY-18 is about.
|
||||
"""
|
||||
wall = _time38.time()
|
||||
q0 = (int(wall) // 900) * 900
|
||||
mono0 = _time38.monotonic() - (wall - q0)
|
||||
t = float(q0)
|
||||
while t < wall:
|
||||
_s38_feed(c, w, datetime.fromtimestamp(t, timezone.utc), mono0 + (t - q0))
|
||||
t += 10.0
|
||||
|
||||
|
||||
def _s38_frozen_ctrl(hass, ratings, unchanged_s=600.0, gain=0.05):
|
||||
# ⚠️ `gain` 0.05 IS THE SCHEMA FLOOR AND IT IS HERE TO BUY A RAMP. At the
|
||||
# shipped 0.6 the loop is at the rail on cycle 0 and the fixture has no
|
||||
# BELOW-the-rail cycles to use as its counterfactual. At 0.05 the site
|
||||
# climbs 125 W a cycle and crosses 475 W part way through the run, so the
|
||||
# SAME run carries both answers.
|
||||
c = _s38_ctrl(hass, ratings, meter_source="homewizard_local",
|
||||
p1_host="meter.local", gain=gain)
|
||||
c.p1_source = _S38Src(unchanged_s)
|
||||
return c
|
||||
|
||||
|
||||
async def _s38_frozen(ratings, meter_w=_S38_FROZEN_METER_W, n=8):
|
||||
hass = _S38Plant()
|
||||
c = _s38_frozen_ctrl(hass, ratings)
|
||||
_s38_seed_quarter(c, meter_w)
|
||||
seen = []
|
||||
for _ in range(n):
|
||||
_s38_feed(c, meter_w)
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
pg = c.peak_guard
|
||||
seen.append(dict(stood=_s38_stood(c),
|
||||
blind=None if pg is None else pg.blind,
|
||||
floor=None if pg is None else pg.floor_w))
|
||||
await asyncio.sleep(0.05)
|
||||
return c, seen
|
||||
|
||||
|
||||
_c38f, _s38f = asyncio.run(_s38_frozen((_S38_A_W, _S38_B_W)))
|
||||
_RAIL38 = _rail_w38(_c38f.site_max_w,
|
||||
dev_min=_c38f.site_dev_bound("dev_min"),
|
||||
dev_max=_c38f.site_dev_bound("dev_max"))
|
||||
_last38 = _s38f[-1]
|
||||
_below38 = [x for x in _s38f if abs(sum(x["stood"])) < _RAIL38]
|
||||
print(f" site rail {_RAIL38:.0f} W of site_max_w {_c38f.site_max_w:.0f} W; "
|
||||
f"meter stuck at {_S38_FROZEN_METER_W:+.0f} W for "
|
||||
f"{_c38f.p1_source.unchanged_s:.0f} s (freeze hold "
|
||||
f"{_c38f.freeze_wd.cfg.hold_s:.0f} s)")
|
||||
for _x in _s38f:
|
||||
print(" stood %-16s sum %+7.1f W floor=%s blind=%r"
|
||||
% ([round(v) for v in _x["stood"]], sum(_x["stood"]),
|
||||
_x["floor"], _x["blind"]))
|
||||
check("PRECONDITION: at the rail EVERY per-unit share is BELOW the site rail "
|
||||
"and their SUM is at or over it - the same discrimination as 9a, at "
|
||||
"SAFETY-18's threshold instead of SAFETY-30's. `[0]`, the mean and the "
|
||||
"largest share are 220, 250 and 280 W against a 475 W rail",
|
||||
len(_last38["stood"]) >= 2
|
||||
and all(abs(s) < _RAIL38 for s in _last38["stood"])
|
||||
and abs(sum(_last38["stood"])) >= _RAIL38
|
||||
and len({round(v, 6) for v in
|
||||
(sum(_last38["stood"]),
|
||||
sum(_last38["stood"]) / len(_last38["stood"]),
|
||||
max(_last38["stood"], key=abs),
|
||||
_last38["stood"][0])}) == 4)
|
||||
check("⚠️ THE PEAK GUARD GOES BLIND ON SAFETY-18's CONJUNCTION and forbids "
|
||||
"charging - floor 0 W - because the SITE's total command is at the rail "
|
||||
"while the meter has stopped moving. Under `sum -> mean` and "
|
||||
"`sum -> max(key=abs)` it is not blind at all and files no floor, so the "
|
||||
"battery may keep importing through an unmeasurable billed quarter. This "
|
||||
"is the second consumer, and it is covered rather than scoped out",
|
||||
_last38["blind"] == _pg38.BLIND_FROZEN and _last38["floor"] == 0.0)
|
||||
check("...and the counterfactual, from the SAME run: on the earlier cycles the "
|
||||
"site command had not yet reached the rail, and the guard did NOT report "
|
||||
"SAFETY-18 - with the meter equally frozen the whole time. So the "
|
||||
"verdict is produced by the COMMAND MAGNITUDE `site_standing` carries, "
|
||||
"not by `unchanged_s` alone",
|
||||
len(_below38) >= 2
|
||||
and all(x["blind"] != _pg38.BLIND_FROZEN for x in _below38))
|
||||
|
||||
|
||||
print()
|
||||
print("9c. AT ONE INVERTER NOTHING CHANGES, and 'nothing' is asserted")
|
||||
# ⚠️ THE REASON THIS SUBSECTION EXISTS. At a roster of one `standing` has a
|
||||
# single entry, so `sum`, the mean, `max(key=abs)` and `[0]` are THE SAME
|
||||
# NUMBER: all three mutations are genuinely EQUIVALENT there and no fixture at
|
||||
# N=1 can ever separate them. That is a fact about the arithmetic, and leaving
|
||||
# it implicit is how "the shipped install is covered" gets believed. It is
|
||||
# asserted here, on a real one-inverter controller's own standing command, so
|
||||
# the claim rests on the roster rather than on the reader.
|
||||
_S38_ONE = (500.0,)
|
||||
|
||||
|
||||
async def _s38_one():
|
||||
hass = _S38Plant()
|
||||
c = _s38_frozen_ctrl(hass, _S38_ONE)
|
||||
_s38_seed_quarter(c, _S38_FROZEN_METER_W)
|
||||
for _ in range(8):
|
||||
_s38_feed(c, _S38_FROZEN_METER_W)
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
await asyncio.sleep(0.05)
|
||||
return c
|
||||
|
||||
|
||||
_c38one = asyncio.run(_s38_one())
|
||||
_one38 = _s38_stood(_c38one)
|
||||
_onered38 = (sum(_one38), sum(_one38) / max(1, len(_one38)),
|
||||
max(_one38, key=abs), _one38[0])
|
||||
print(f" roster of {len(_c38one.inverters)}: stood "
|
||||
f"{[round(v) for v in _one38]} -> sum/mean/max/first = "
|
||||
f"{tuple(round(v, 1) for v in _onered38)}")
|
||||
check("at a roster of ONE the four reductions are ONE NUMBER - so all three "
|
||||
"mutations of `site_standing` are EQUIVALENT on a shipped install and no "
|
||||
"N=1 fixture could ever tell them apart. That is why this card needed a "
|
||||
"roster of two, stated as an assertion rather than left to the reader",
|
||||
len(_c38one.inverters) == 1
|
||||
and len({round(v, 6) for v in _onered38}) == 1)
|
||||
check("...and the one-inverter site still reaches SAFETY-18's verdict on that "
|
||||
"same number, unchanged: the command is at the rail, the meter has "
|
||||
"stopped moving, the guard is blind and forbids charging",
|
||||
_c38one.peak_guard is not None
|
||||
and _c38one.peak_guard.blind == _pg38.BLIND_FROZEN
|
||||
and _c38one.peak_guard.floor_w == 0.0
|
||||
and abs(sum(_one38)) >= _rail_w38(
|
||||
_c38one.site_max_w,
|
||||
dev_min=_c38one.site_dev_bound("dev_min"),
|
||||
dev_max=_c38one.site_dev_bound("dev_max")))
|
||||
check("...and the SITE sign detector is still absent at a roster of one - part "
|
||||
"7 counts the calls; this only records that a fixture built the other "
|
||||
"way round, from an `inverters:` roster, reaches the same state",
|
||||
not _c38one.site_sign_wd.tripped
|
||||
and _c38one.site_sign_wd.disagree_since is None)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
|
||||
Reference in New Issue
Block a user