Compare commits
4
Commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
8b9680fc35 | ||
|
|
3ce18708b6 | ||
|
|
78acb558ff | ||
|
|
0f14c2a5de |
+1
-1
@@ -1,2 +1,2 @@
|
||||
# The admin/goodwe commit CI tests against. Bump: set to the full SHA of admin/goodwe release/1.0 HEAD (README.md, "CI and the infra pin").
|
||||
0c04488a9194039c2bf851b680a8ffc53beff671
|
||||
d637d0b1b13f1b863dc47e445e2ca4cf4a82fe10
|
||||
|
||||
@@ -1,74 +0,0 @@
|
||||
# SAFETY-91 - a held battery is drawn only after the others are full
|
||||
|
||||
**Status: DECIDED 2026-10-01 (owner: held battery last, SAFETY-25 option A
|
||||
kept).** Follows SAFETY-87. Tests: `test_safety91.py`.
|
||||
|
||||
**The defect** (SAFETY-87 rig test, F1 and F2). At N>=2 a battery at or under
|
||||
its own peak reserve was held back (weight 0) only on cycles where the peak
|
||||
guard asked for power.
|
||||
- F1: B draining at 1000 W, A held at 15 %, house 5500. Once the grid was
|
||||
near zero the loop set the target, A had its normal weight and B's drain
|
||||
pin bound, so the loop drew A at 2500 W for the whole quarter (15.0 ->
|
||||
10.7 %) while B stayed at 1000 W. In the next quarter A reached its
|
||||
cut-out, and B stayed pinned at the peak floor (~2422 W), not its 2500 W.
|
||||
- F2: in a HOLD (A holding, B held), at a quarter's edge the guard saw a block
|
||||
with no seconds left and asked for nothing for one cycle. The HOLD's
|
||||
ceiling lapsed, A went back to 0 W and the loop's target went to B: 2500 W
|
||||
for 1 s.
|
||||
|
||||
**The fix** (`main.py`, N>=2 only).
|
||||
- `_held_back()`: the batteries at or under their own reserve while another
|
||||
can still give (live, not refusing), graded as in `_peak_on_able()`. They
|
||||
weigh 0 in every split where the site gives, not only for the peak. With
|
||||
nobody able (all held, or the rest refusing or dropped) nobody is held back
|
||||
and the split is as before.
|
||||
Review: once held back, a battery stays so until its SoC reads more than 1
|
||||
point above its reserve. A reading flipping 20/21 % otherwise swapped
|
||||
~1000 W between the batteries on each flip (grid +-500 W with A 10 s and
|
||||
B 3 s lag). The guard's own permission (SAFETY-87) is unchanged.
|
||||
- `_drain_rise()`: while a battery is held back, a draining battery's pin
|
||||
becomes a floor at its drain rate (`lo`), so it rises towards its rating
|
||||
before the held one gives. Not for a held battery's own drain, not under a
|
||||
site stop, not for a battery that is not live.
|
||||
- `tariff.next_quarter()`: past a block's end, before the next block's first
|
||||
telegram, the guard grades the next quarter, projected from the held
|
||||
reading (the averager credits it there). Not when that reading is too old
|
||||
to be credited (`max_hold_s`).
|
||||
|
||||
**What stays.** SAFETY-25 option A: once every able or draining battery is
|
||||
at full power, the loop still draws a held battery (`allocator._fill()`'s
|
||||
last-resort pass). With house 5500 and 2 x 2500 W, A still gives 2500 W
|
||||
after B is full. Nothing is placed on a battery at its cut-out: OPT-09's
|
||||
pack limit closes it (`hi = 0`), and the drain rise lets B take the rest.
|
||||
|
||||
**Before -> after** (`test_safety91.py`, 2 x 2500 W, lagging battery 10 s):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| B drain 1000, A held, house 4000 | A 2500, B 1000 | A 1500, B 2500 |
|
||||
| same, house 5500 | A 2500, B 1000 | A 2500, B 2500 (option A) |
|
||||
| cycles A asked while B not full | 612 of 900 | 0 |
|
||||
| A at its cut-out, house 5500: B | 1572 W mean | 2500 W, A 0 W |
|
||||
| HOLD, late telegram at the edge | A 0, B 2470 for 1 cycle | A 2050, B 0 |
|
||||
| idle, A held, house 2000 | A 1005, B 1005 | A 0, B 2020 |
|
||||
| N=1, every scenario | | byte-identical |
|
||||
|
||||
**Why N>=2 only.** At N=1 there is no other battery to give first. The edge
|
||||
roll would also fix the N=1 one-cycle dip at a quarter's edge (SAFETY-86
|
||||
rig, "A dropped to 0 W for 1 s"), but this ticket keeps N=1 byte-identical;
|
||||
extending it is a one-line change for a later ticket.
|
||||
|
||||
**Re-pinned.** `test_modes.py` `n2` and `n2_off`: from t=1600 battery A is
|
||||
at its 20 % reserve, so B carries the house and A gives last (100 of 540
|
||||
cycles differ). With SAFETY-87's held rule both are a5dddad's again, and the
|
||||
test grades that.
|
||||
Two fixtures changed with it: `test_safety87.py` part 10's "without the
|
||||
raise" run also turns off `_drain_rise()` (else B rises anyway), and
|
||||
`test_peakguard.py` 10g and `test_watchdog.py`'s two-inverter rig give
|
||||
their second battery a cut-out, as rule 8 requires (an unknown cut-out is held, so A alone would carry the cycle).
|
||||
|
||||
**Not changed.** The peak guard's own rules (SAFETY-87). A drain with
|
||||
nobody held stays a pin (SAFETY-78). An Off battery beside a held one
|
||||
(SAFETY-87 Open). The first cycle after start, before any quarter is
|
||||
measured, can still put the loop's first step on a held battery in a HOLD.
|
||||
SAFETY-88, -89, -90, -92, -93, -94.
|
||||
@@ -1,60 +0,0 @@
|
||||
# SAFETY-93 - the maintenance charge end hands back smoothly
|
||||
|
||||
**Status: implemented 2026-10-02, for review.** Tests: `test_safety93.py`.
|
||||
|
||||
**The defect** (SAFETY-85 rig test, check 4; also on 9358781). At N=2, when
|
||||
A's maintenance charge ended, B went 0 -> -1600 W in one cycle and charged
|
||||
from the grid with the house at 6000 W. The HOLD end was already smooth
|
||||
(SAFETY-85).
|
||||
|
||||
**Cause.** During the charge the site target holds A's charge (SAFETY-84's
|
||||
`charge` ceiling, -2000 W). At the end A gets its HOLD pin (0 W), but the
|
||||
loop starts its next step from last cycle's site target. The slew limit
|
||||
moves the site total by 400 W (-2000 -> -1600), and the only battery left
|
||||
to place it on is B. The same happens when the charge times out or the
|
||||
battery is switched Off (A free, its -2000 W shared out). With the charge
|
||||
suspended by the guard and A giving under the loop, B took A's share in
|
||||
one step (675 W).
|
||||
|
||||
**The fix** (`main.py`, `_reseed_charge_end()`, N>=2 only). On the cycle a
|
||||
battery leaves CHARGE, the loop's start point (`self.target`, and the
|
||||
integrator with it) is what the other batteries stood at plus that
|
||||
battery's new command: its pin (HOLD or abort, 0 W), or, if it is free, its
|
||||
last discharge (a charge stops). The loop then moves from there one slew
|
||||
step a cycle. The ending battery's own step (-2000 -> 0 W) is maintenance's
|
||||
pin, as before; it lowers the grid import. The end is kept until the loop
|
||||
next runs, so a missed poll on that cycle (the input hold) does not lose it.
|
||||
|
||||
Review: a charge also ends, for the site, when the battery is still in
|
||||
CHARGE but can no longer be placed: a stale link or a refusal (SAFETY-73)
|
||||
drops it, and its -2000 W landed on B the same way (B 0 -> -1600 W at a
|
||||
1200 W house). So the end is noted after the unit claims are filed: a
|
||||
battery leaves the charge when it leaves CHARGE, is not live, or its own
|
||||
claims contradict. The guard suspending the charge (SAFETY-84) is no end.
|
||||
|
||||
Why a start-point reseed, and not a per-battery slew in the allocator: the
|
||||
jump comes from one stale number at one edge, the kind of edge SAFETY-73
|
||||
(`_unit_refusal_end`) and OPT-11 P3 (`_reseed_run_edge`) already reseed.
|
||||
The change stays at that edge; nothing else at N>=2 moves.
|
||||
|
||||
**Before -> after** (`test_safety93.py`, 2 x 2500 W, 10 s lag, 2 s meter):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| rig case: house 6000, A charges 2000 to the end | B 0 -> -1600, charges 4 cycles | B 0 -> 400 -> 800 ..., never charges |
|
||||
| house 1200 | B 0 -> -1600 (2800 W from the grid) | B steps of 400, never charges |
|
||||
| charge times out / A switched Off | B 0 -> -1600 | B 0 -> 400 |
|
||||
| guard suspended the charge, A gives 1825 | B step 675 W | B step 395 W |
|
||||
| missed poll on the end cycle | B 0 -> -1600 a cycle later | B 0 -> 400 |
|
||||
| A dropped mid-charge (stale link, refusal), house 1200 | B 0 -> -1600 | B 0 -> 400 |
|
||||
| N=1, both charge ends above | | byte-identical |
|
||||
|
||||
No pinned digest moved: the 46 digests of `tools/*identity*.py` (N=1 and
|
||||
N=2) are byte-identical to f3e409c; none of their scenarios reaches a
|
||||
charge end.
|
||||
|
||||
**Not changed.** The peak guard's floor still moves the site in one step
|
||||
when it engages (a house step, a quarter edge): the guard outranks the slew
|
||||
(owner order). A HOLD pin still drops the holding battery to 0 W at once
|
||||
and SAFETY-86 gives way to the others first. SAFETY-88 (charge flapping
|
||||
above the aim) is untouched.
|
||||
@@ -1640,7 +1640,7 @@ help - see "Why the tuning is what it is".
|
||||
| `maintenance_enabled` | false | Enable the monthly cycle |
|
||||
| `maintenance_interval_days` | 28 | Minimum gap between cycles |
|
||||
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
|
||||
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). The peak guard may ask for more (SAFETY-83; at N≥2 while another battery is at its peak reserve, SAFETY-87), and at N≥2 so may the house while another battery is at its peak reserve (SAFETY-91). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
||||
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). The peak guard may ask for more (SAFETY-83; at N≥2 while another battery is at its peak reserve, SAFETY-87). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
||||
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
|
||||
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor. ⚠️ **This is not `peak_soc_floor`.** It is the depth the monthly recalibration deliberately goes to, once, on purpose; `peak_soc_floor` is the depth a money-saving discharge may never reach on any day. The right values differ (11 vs 20 as shipped), which is why they are two keys |
|
||||
| `maintenance_soc_target` | 99 | Charge target |
|
||||
@@ -1667,9 +1667,6 @@ others only add power when the house needs more; none charges while it drains
|
||||
(SAFETY-78). Below the drain rate the rest is exported, as with one battery.
|
||||
If the house would still go over the peak limit, the battery being emptied
|
||||
gives more than its drain rate, with one battery too (SAFETY-83).
|
||||
A battery at its peak reserve gives last: the others give their full power
|
||||
first, and the battery being emptied rises above its drain rate before it
|
||||
(SAFETY-91).
|
||||
In a cheap window the battery being filled charges and the others only add
|
||||
charge; none gives while it charges. The charge is cut to what keeps the
|
||||
15-minute peak at the limit minus `peak_margin_w` (SAFETY-84).
|
||||
@@ -1677,8 +1674,6 @@ While a full battery rests after its charge (the hold), it gives just enough
|
||||
to keep the 15-minute peak at that aim if the house needs it; with two
|
||||
batteries the other one gives first. The hold still ends on its clock
|
||||
(SAFETY-86).
|
||||
When a charge ends, the other batteries take over one slew step a cycle,
|
||||
and none starts charging from the grid (SAFETY-93).
|
||||
|
||||
#### Capacity-tariff exposure of the grid-following loop
|
||||
|
||||
@@ -1814,9 +1809,7 @@ exactly like the SoC drift the monthly maintenance cycle exists to correct.
|
||||
It will discharge straight past this number and keep going until the pack's own
|
||||
BMS cut-out stops it. What you are promised by `peak_soc_floor: 20` is *"the
|
||||
capacity-peak guard will not spend the pack for money below 20 %"*, and
|
||||
**nothing more**. See below for what that costs on a real evening. With two
|
||||
or more batteries, one under it is used last: only once the others give
|
||||
their full power (SAFETY-91).
|
||||
**nothing more**. See below for what that costs on a real evening.
|
||||
- **When it binds you are told**, once per episode, with notification
|
||||
`goodwe_peak_soc_floor` and a red status-page row reading *Battery at its
|
||||
peak reserve* (`PEAK_GUARD_FLOOR_LIMITED` in the log): the quarter **will**
|
||||
|
||||
@@ -737,9 +737,9 @@ def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
gate, held = _unit_modes(out, site_claims, bounds, live)
|
||||
if callable(weights):
|
||||
weights = weights(out.target_w)
|
||||
# SAFETY-87/91: units under their peak reserve weigh 0 while the site
|
||||
# gives, so the others carry the target first. An Off battery gives the
|
||||
# peak's shortfall, so it goes before them when no other unit is left.
|
||||
# SAFETY-87: units under their peak reserve weigh 0 while the site gives,
|
||||
# so the others carry the peak floor. An Off battery gives the peak's
|
||||
# shortfall, so it goes before them when no other unit is left.
|
||||
reserve = set(reserve) if out.target_w > 0.0 else set()
|
||||
if held and reserve and not set(bounds) - held - reserve:
|
||||
held = set()
|
||||
|
||||
@@ -75,8 +75,8 @@ from .hass import HomeAssistant
|
||||
from .inverter import (LINK_STALE_S, UNIT_A, build_roster,
|
||||
roster_entries, roster_names)
|
||||
from .maintenance import (
|
||||
CHARGE, DRAIN, HOLD, IDLE, POWER_MOVING, MaintConfig, Maintenance,
|
||||
MaintResult, arbitrate as maint_arbitrate,
|
||||
DRAIN, HOLD, IDLE, POWER_MOVING, MaintConfig, Maintenance, MaintResult,
|
||||
arbitrate as maint_arbitrate,
|
||||
)
|
||||
from .mqtt import (MODE_CONFIGS_KEY, MODE_LABELS, USE_OFF, USE_ON,
|
||||
MqttPublisher, announced_units, mode_configs,
|
||||
@@ -91,7 +91,7 @@ from .price import required_spread as price_required_spread
|
||||
from .price import uncertainty_of as price_uncertainty_of
|
||||
from .price_history import PriceHistory
|
||||
from .static_tariff import resolve_tariff, static_status
|
||||
from .tariff import PeakStore, PeakTracker, next_quarter
|
||||
from .tariff import PeakStore, PeakTracker
|
||||
from .store import migrate_maint_keys, migrate_unit_keys
|
||||
from .validate import (FIRMWARE_INGEST_VETO_S, ConfigRefused, refuse,
|
||||
validate_startup_config, validate_unit_ranges)
|
||||
@@ -992,12 +992,6 @@ class Controller:
|
||||
# SAFETY-78: names of draining packs that cannot give power now, so
|
||||
# the "waits" line is logged once, not every cycle.
|
||||
self._drain_waits = set()
|
||||
# SAFETY-91: last cycle's held-back batteries (`_held_back()`).
|
||||
self._held_was = frozenset()
|
||||
# SAFETY-93: the batteries placed in their maintenance charge last
|
||||
# cycle, and those whose charge ended since the loop last ran.
|
||||
self._charging_was = frozenset()
|
||||
self._charge_ended = frozenset()
|
||||
# Set by amain() once the transport is built, so the status page can show
|
||||
# what only the transport knows (homewizard_local's unchanged_s). Stays
|
||||
# None when P1 is off, or under a transport that has no such counter.
|
||||
@@ -2372,39 +2366,6 @@ class Controller:
|
||||
self.target = want
|
||||
self.i_w = want - self.tuning.gain * (want - float(batt))
|
||||
|
||||
def _charge_track(self, claims, maint_results) -> None:
|
||||
"""SAFETY-93, N>=2: a charge ends when its battery leaves CHARGE or can
|
||||
no longer be placed (stale link, refusal). Kept until the loop runs."""
|
||||
if len(self.inverters) < 2:
|
||||
return
|
||||
live = set(self.live_units())
|
||||
now = set()
|
||||
for inv, res in zip(self.inverters, maint_results):
|
||||
u = self.actuator_of("maintenance", inv)
|
||||
if res.phase == CHARGE and u in live and not pre_resolve(
|
||||
[c for c in claims if c.actuator == u]).contradiction:
|
||||
now.add(inv.name)
|
||||
self._charge_ended |= self._charging_was - now
|
||||
self._charging_was = frozenset(now)
|
||||
|
||||
def _reseed_charge_end(self, maint_results) -> None:
|
||||
"""SAFETY-93, N>=2: when a battery's maintenance charge ends, the loop
|
||||
starts from what the others stood at plus that battery's new command
|
||||
(its HOLD pin, or its last discharge if it is free; a charge stops).
|
||||
Else the charge's watts stay in the site target and land on the
|
||||
others: B 0 -> -1600 W in one cycle. DECISIONS/SAFETY-93-charge-end.md.
|
||||
"""
|
||||
ended, self._charge_ended = self._charge_ended, frozenset()
|
||||
if len(self.inverters) < 2 or not ended:
|
||||
return
|
||||
for inv, res in zip(self.inverters, maint_results):
|
||||
if inv.name not in ended:
|
||||
continue
|
||||
now_w = (float(res.setpoint_w or 0.0) if res.owns_setpoint
|
||||
else max(float(inv.target), 0.0))
|
||||
self.target += now_w - float(inv.target)
|
||||
self.i_w = self.target
|
||||
|
||||
def _mode_fault_log(self, resolution) -> None:
|
||||
"""OPT-11: say once, per battery, that its mode was dropped as a fault.
|
||||
|
||||
@@ -2606,58 +2567,6 @@ class Controller:
|
||||
return frozenset()
|
||||
return frozenset(g.held)
|
||||
|
||||
def _held_back(self) -> frozenset:
|
||||
"""SAFETY-91, N>=2: the batteries at or under their own peak reserve
|
||||
while another can still give (live, not refusing). They weigh 0 in
|
||||
every split where the site gives, so they give last (SAFETY-25
|
||||
option A: still drawn once the others are full). One held back
|
||||
stays so until its SoC reads more than 1 point above its reserve, so
|
||||
a reading flipping across it does not swap the split each cycle."""
|
||||
if len(self.inverters) < 2:
|
||||
return frozenset()
|
||||
floor = float(self.o.get(
|
||||
"peak_soc_floor", peakguard.PEAK_OPTION_DEFAULTS["peak_soc_floor"]))
|
||||
ok, held = peakguard.reserve_split(self.packs, floor)
|
||||
held = set(held) | {
|
||||
p.name for p in ok if p.name in self._held_was
|
||||
and float(p.soc) <= peakguard.pack_floor_pct(p, floor) + 1.0}
|
||||
live = set(self.live_units())
|
||||
if not held or not any(
|
||||
p.name not in held and inv.name in live
|
||||
and not (inv.refused or 0) > 0
|
||||
for p, inv in zip(self.packs, self.inverters)):
|
||||
self._held_was = frozenset()
|
||||
else:
|
||||
self._held_was = frozenset(held)
|
||||
return self._held_was
|
||||
|
||||
def _drain_rise(self, claims, maint_results) -> None:
|
||||
"""SAFETY-91, N>=2: while a battery is held back (`_held_back()`), a
|
||||
draining battery's pin becomes a floor at its drain rate, so it rises
|
||||
towards its rating before the held one gives. A site stop still
|
||||
decides alone. DECISIONS/SAFETY-91-held-battery-last.md."""
|
||||
held = self._held_back()
|
||||
if not held or any(c.kind == SET and c.actuator == ACTUATOR_SITE
|
||||
and c.priority > P_PEAK for c in claims):
|
||||
return
|
||||
live = set(self.live_units())
|
||||
for inv, res in zip(self.inverters, maint_results):
|
||||
u = self.actuator_of("maintenance", inv)
|
||||
if res.phase != DRAIN or not res.owns_setpoint \
|
||||
or inv.name in held or u not in live:
|
||||
continue
|
||||
b = pre_resolve([c for c in claims if c.actuator == u])
|
||||
p = (None if b.contradiction or b.pinned_by != "maintenance"
|
||||
else allocator.pin_w(b))
|
||||
if p is None or not p > 0.0:
|
||||
continue
|
||||
for i, c in enumerate(claims):
|
||||
if c.source == "maintenance" and c.kind == SET \
|
||||
and c.actuator == u:
|
||||
claims[i] = Claim.limit("maintenance", P_MAINTENANCE,
|
||||
lo=p, reason=c.reason,
|
||||
actuator=u)
|
||||
|
||||
def _peak_over_drain(self, claims, maint_results) -> None:
|
||||
"""SAFETY-83: at N=1 a peak floor above the drain rate outranks it.
|
||||
|
||||
@@ -4173,11 +4082,6 @@ class Controller:
|
||||
# gives for SAFETY-18 on a transport that cannot see `unchanged_s`.
|
||||
self._peak_proj = (None if not self.p1_enabled
|
||||
else self.peak.project(self.p1.averager, now))
|
||||
# SAFETY-91: at N>=2 the quarter's edge is graded on the next quarter,
|
||||
# so a HOLD's ceiling does not lapse for a cycle onto a held battery.
|
||||
if self._peak_proj is not None and len(self.inverters) > 1:
|
||||
self._peak_proj = next_quarter(self._peak_proj,
|
||||
self.p1.averager.max_hold_s)
|
||||
self.peak_guard = None if not self.p1_enabled else peakguard.decide(
|
||||
self._peak_proj,
|
||||
# ⚠️ THE SITE SUM. The guard sizes a floor from what the battery is
|
||||
@@ -4578,8 +4482,6 @@ class Controller:
|
||||
claims.append(Claim.limit("hold", P_MAINTENANCE, hi=hold_hi,
|
||||
reason="maintenance hold",
|
||||
actuator=self.actuator_of("hold")))
|
||||
# --- SAFETY-91: a drain rises before a held battery gives ------------
|
||||
self._drain_rise(claims, maint_results)
|
||||
# --- SAFETY-84: a cheap-window charge is a ceiling over the site ----
|
||||
charge = self._charge_ceiling(claims)
|
||||
if charge is not None:
|
||||
@@ -4593,7 +4495,6 @@ class Controller:
|
||||
if self.modes_on:
|
||||
mode_trade = self._mode_trade(claims, now)
|
||||
self._mode_trade_was = mode_trade
|
||||
self._charge_track(claims, maint_results)
|
||||
if (self.auto or self.shadow) and self.inputs_ok:
|
||||
# ⚠️ prev is the ARBITER's last output, not the loop's own last
|
||||
# wish. If something outranked the loop, that is what the hardware
|
||||
@@ -4620,8 +4521,6 @@ class Controller:
|
||||
# is what seeds it, and dropping it there restarts the ~70 s cycle.
|
||||
if self.loop_w is not None and self.target != self.loop_w:
|
||||
self._refusal_end("another writer")
|
||||
# SAFETY-93: a charge that ended leaves the loop's start point.
|
||||
self._reseed_charge_end(maint_results)
|
||||
probe = self._refusal_probe()
|
||||
if len(self.inverters) > 1:
|
||||
probe = any(_probing.values())
|
||||
@@ -4781,7 +4680,7 @@ class Controller:
|
||||
while True:
|
||||
resolution = resolve(claims, units=self.units, live=_live,
|
||||
weights=self.pack_weights, tick=self.alloc_tick,
|
||||
reserve=self._held_back())
|
||||
reserve=self._peak_reserve())
|
||||
# SAFETY-73: a probe pin stands only while the resolved site target
|
||||
# asks at least PROBE_W its way. Below that a sibling would carry
|
||||
# the opposite direction (circulation), so the pin goes back to the
|
||||
|
||||
@@ -822,22 +822,6 @@ class PeakTracker:
|
||||
held_w=averager.held_net_w)
|
||||
|
||||
|
||||
def next_quarter(p: Projection, max_hold_s: float) -> Projection:
|
||||
"""SAFETY-91: `p` past its block's end, before the next block's first
|
||||
telegram: the next quarter, projected from the held reading (the averager
|
||||
credits it there). `p` itself otherwise, or when that reading is too old
|
||||
to be credited. DECISIONS/SAFETY-91-held-battery-last.md."""
|
||||
if p.block_start is None or p.elapsed_s < QUARTER_S \
|
||||
or p.elapsed_s * (1.0 - p.covered_frac) > float(max_hold_s):
|
||||
return p
|
||||
held = max(p.held_w, 0.0)
|
||||
return Projection(projected_w=held, elapsed_w=held,
|
||||
elapsed_s=p.elapsed_s - QUARTER_S, covered_frac=1.0,
|
||||
complete=True,
|
||||
block_start=p.block_start + timedelta(seconds=QUARTER_S),
|
||||
held_w=p.held_w)
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class _ClosedBlock:
|
||||
"""A block reconstructed from a checkpoint. Shaped like `p1.QuarterBlock` so
|
||||
|
||||
@@ -129,19 +129,6 @@ finally:
|
||||
# cd4d9cb5b7e29ff4ab4fe65dab5106683d8a599f09323fbdee4018ad9b28fcd1.
|
||||
SAFETY78_N2_MAINT = \
|
||||
"1afcd46b1b987868b110d2b0f4a7555848c9aa4728a836d4a2ce2a2107268497"
|
||||
# SAFETY-91 changes n2 and n2_off ON PURPOSE: from t=1600 battery A is at its
|
||||
# 20 % reserve, so B carries the house first and A gives last. With
|
||||
# `_held_back()` reverted to SAFETY-87's (held only for the peak) both are
|
||||
# a5dddad's again, which the check below grades.
|
||||
SAFETY91_N2 = \
|
||||
"9535c08f556d6d50bec8fb0872445173480c29b10df1a7c437ef73d6ddb2814d"
|
||||
_real_hb = app_main.Controller._held_back
|
||||
app_main.Controller._held_back = lambda self: self._peak_reserve()
|
||||
try:
|
||||
_n2_s87 = rig.digest(rig.run(**rig.SCENARIOS["n2"])[0])
|
||||
finally:
|
||||
app_main.Controller._held_back = _real_hb
|
||||
_S91 = ("n2", "n2_off", "n2_maint")
|
||||
for k in A5DDDAD:
|
||||
print(f" {k:7} {'same' if _now[k] == A5DDDAD[k] else 'DIFFERS'} "
|
||||
f"{_now[k][:16]}")
|
||||
@@ -149,14 +136,10 @@ check("⭐ at N=1 and N=2, with the option absent and with it false, every "
|
||||
"command, reason and allocation record over 540 cycles each is "
|
||||
"byte-identical to a5dddad (house steps, a solar surplus, a battery "
|
||||
"at its cut-out level, at N=2 a refusal with probes, both batteries "
|
||||
"due for maintenance; n2, n2_off and n2_maint apart, below), and so "
|
||||
"is the arbiter on 6000 claim lists",
|
||||
{k: v for k, v in _now.items() if k not in _S91}
|
||||
== {k: v for k, v in A5DDDAD.items() if k not in _S91})
|
||||
check("...n2 and n2_off are the SAFETY-91 digest (A at its reserve gives "
|
||||
"last), and SAFETY-87's held rule gives a5dddad's back",
|
||||
_now["n2"] == _now["n2_off"] == SAFETY91_N2 != A5DDDAD["n2"]
|
||||
and _n2_s87 == A5DDDAD["n2"])
|
||||
"due for maintenance; n2_maint apart, below), and so is the arbiter "
|
||||
"on 6000 claim lists",
|
||||
{k: v for k, v in _now.items() if k != "n2_maint"}
|
||||
== {k: v for k, v in A5DDDAD.items() if k != "n2_maint"})
|
||||
check("...and n2_maint is the SAFETY-78 digest: the N=2 drain that a5dddad "
|
||||
"refused on 392 of 540 cycles now runs (test_safety78.py), bounded by "
|
||||
"SAFETY-85",
|
||||
|
||||
@@ -3132,10 +3132,6 @@ check("...and between them the nineteen appends account for exactly the "
|
||||
# through this file's reading of main.py. It grades three of the eight appends.
|
||||
# The static pin above is what covers the other five.
|
||||
_b2, _restore_b2 = second_inverter(c_src)
|
||||
# SAFETY-91: B states a cut-out, as every roster entry must (rule 8). Without
|
||||
# one it is held back at its reserve and gives last, so A alone would carry
|
||||
# this cycle's 500 W and the broadcast check below could not see a split.
|
||||
_b2.bms_soc_floor = c_src.inverters[0].bms_soc_floor
|
||||
_n2_writes_before = len(c_src.hass.per_entity)
|
||||
try:
|
||||
_, _cl2 = cycle_claims(lambda: run_cycle(c_src))
|
||||
|
||||
@@ -559,14 +559,11 @@ def _drain_run():
|
||||
|
||||
DR = _drain_run()
|
||||
_real_dor = Controller._drain_over_reserve
|
||||
_real_rise = Controller._drain_rise # SAFETY-91 would raise B as well
|
||||
Controller._drain_over_reserve = lambda self, claims, results: None
|
||||
Controller._drain_rise = lambda self, claims, results: None
|
||||
try:
|
||||
DR_OLD = _drain_run()
|
||||
finally:
|
||||
Controller._drain_over_reserve = _real_dor
|
||||
Controller._drain_rise = _real_rise
|
||||
|
||||
|
||||
def _a_for_peak(rows):
|
||||
|
||||
@@ -1,452 +0,0 @@
|
||||
"""Runnable check for SAFETY-91: a held battery is drawn only after the others
|
||||
are full. `python3 test_safety91.py`
|
||||
|
||||
At N>=2 a battery at or under its peak reserve was held back only while the
|
||||
peak guard asked for power. The self-consumption loop drew it at its full
|
||||
rating while a draining battery stayed at its drain rate (SAFETY-87 rig test
|
||||
F1), and at a quarter's edge in a HOLD the held battery gave 2500 W for one
|
||||
cycle (F2). Now a held battery weighs 0 whenever the site gives, a draining
|
||||
battery rises above its drain rate before it, and the edge is graded on the
|
||||
next quarter. SAFETY-25 option A stands: once the others are full the loop
|
||||
may still draw it. Drives the REAL Controller on a lagging battery (10 s, as
|
||||
on the rig). DECISIONS/SAFETY-91-held-battery-last.md.
|
||||
|
||||
1. B draining, A held, house over B's rating: B rises to full before A gives.
|
||||
2. A held reaching its cut-out: nothing is placed on it, B gives its rating.
|
||||
3. HOLD across a quarter edge: the held battery gives nothing at the edge.
|
||||
4. Idle, A held: B carries the house first; both held or B refusing: as before;
|
||||
a SoC reading flipping across the reserve does not swap the split.
|
||||
5. The rules at their boundaries (claim lists, N=3, a site stop).
|
||||
6. next_quarter() at its boundaries.
|
||||
7. N=1 is untouched.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import logging
|
||||
import math
|
||||
import os
|
||||
import sys
|
||||
import time
|
||||
import types
|
||||
from datetime import timedelta
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
from app import peakguard # noqa: E402
|
||||
from app.arbiter import (Claim, P_MAINTENANCE, P_SAFETY, # noqa: E402
|
||||
resolve)
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.maintenance import DRAIN, HOLD, IDLE, MaintResult # noqa: E402
|
||||
from app.p1 import make_sample, split_signed # noqa: E402
|
||||
from app.store import unit_key # noqa: E402
|
||||
from app.tariff import QUARTER_S, Projection, next_quarter # noqa: E402
|
||||
|
||||
fails = []
|
||||
A, B = "inverter-a", "inverter-b"
|
||||
FULL = 2500.0
|
||||
CUT = 10.0 # bms_soc_floor of both test batteries
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def lagging(fn, lag=10.0, tick=1.0, lags=None):
|
||||
"""`fn` on plantsim's battery (800 W/s ramp, `lag` s first-order lag, or
|
||||
`lags[u]`), a 1 s meter tick, and a BMS that stops discharge at its
|
||||
cut-out."""
|
||||
real_p, real_t = rig._Hass.power, rig.TICK
|
||||
|
||||
def power(self, u):
|
||||
st = self.__dict__.setdefault("_plant", {})
|
||||
a, tgt, tl = st.get(u, (0.0, 0.0, self.t))
|
||||
for _ in range(int(round((self.t - tl) / 0.1))):
|
||||
d = self.cmd[u] - tgt
|
||||
tgt += math.copysign(min(abs(d), 80.0), d)
|
||||
a += (tgt - a) * (1 - math.exp(-0.1 / (lags or {}).get(u, lag)))
|
||||
st[u] = (a, tgt, self.t)
|
||||
return 0.0 if self.soc(u, self.t) <= CUT and a > 0 else float(round(a))
|
||||
rig._Hass.power, rig.TICK = power, tick
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
rig._Hass.power, rig.TICK = real_p, real_t
|
||||
|
||||
|
||||
def store(phase_of, n=2):
|
||||
"""`phase_of`: {name: phase}; the others have just done their cycle."""
|
||||
s = rig._Store()
|
||||
for u in (A, B)[:n]:
|
||||
key = (lambda k: k) if n == 1 else (lambda k: unit_key(u, k))
|
||||
if u in phase_of:
|
||||
s.data[key("phase")] = phase_of[u]
|
||||
s.data[key("phase_started")] = rig.BASE.isoformat()
|
||||
else:
|
||||
s.data[key("last_completed")] = rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
def run(house, phase_of, socs, dur, late=0.0, kwh=15.36, n=2, read=None,
|
||||
lags=None):
|
||||
"""Rows and controller. Levels follow each battery's measured power; the
|
||||
P1 telegram read at each cycle is `late` s old. `read(u, t, level)` is
|
||||
the SoC the controller reads (default the level)."""
|
||||
soc, last, levels = dict(socs), [0.0], {}
|
||||
grid = []
|
||||
|
||||
def before(c, t):
|
||||
grid.append((t, c.hass.grid()))
|
||||
for u in soc:
|
||||
soc[u] = max(CUT, soc[u] - c.hass.power(u) * (t - last[0])
|
||||
/ 3600.0 / (kwh * 10.0))
|
||||
last[0], levels[t] = t, dict(soc)
|
||||
imp, exp = split_signed(c.hass.grid())
|
||||
c.p1.submit(make_sample("ha_signed", imp, exp, phases=1,
|
||||
ingest_ts=rig.BASE + timedelta(seconds=t - late),
|
||||
ingest_mono=time.monotonic()))
|
||||
rows, c = lagging(lambda: s84.run(
|
||||
n, load=house if callable(house) else (lambda t: house), cheap=False,
|
||||
store=store(phase_of, n), before=before, dur=dur,
|
||||
soc=(lambda u, t: soc[u]) if read is None
|
||||
else (lambda u, t: read(u, t, soc[u])),
|
||||
extra={"maintenance_discharge_w": 1000,
|
||||
"maintenance_hold_min": 600}), lags=lags)
|
||||
c.levels, c.grid = levels, grid
|
||||
return rows, c
|
||||
|
||||
|
||||
def without_fix(fn):
|
||||
"""release/1.0 8c438ab: held only for the peak, a drain stays pinned, the
|
||||
quarter's edge is not rolled over."""
|
||||
real = (Controller._held_back, Controller._drain_rise)
|
||||
import app.main as m
|
||||
real_nq = m.next_quarter
|
||||
Controller._held_back = lambda self: self._peak_reserve()
|
||||
Controller._drain_rise = lambda self, claims, results: None
|
||||
m.next_quarter = lambda p, max_hold_s: p
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
Controller._held_back, Controller._drain_rise = real
|
||||
m.next_quarter = real_nq
|
||||
|
||||
|
||||
def cmd(r):
|
||||
return dict(r[2])
|
||||
|
||||
|
||||
def seg(rows, lo, hi):
|
||||
"""Mean A and B commands over [lo, hi) s."""
|
||||
rs = [r for r in rows if lo <= r[0] < hi]
|
||||
return (round(sum(cmd(r)["a"] for r in rs) / len(rs)),
|
||||
round(sum(cmd(r)["b"] for r in rs) / len(rs)))
|
||||
|
||||
|
||||
def a_before_b(rows, t0=0.0):
|
||||
"""Cycles where held A is asked to give while B is not at full power."""
|
||||
return sum(1 for r in rows if r[0] >= t0
|
||||
and cmd(r)["a"] > 0.0 and cmd(r)["b"] < FULL)
|
||||
|
||||
|
||||
def unmet(rows, lo, hi):
|
||||
return sum(1 for r in rows if lo <= r[0] < hi and r[7] and "UNMET" in r[7])
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. B draining at 1000 W, A held at 15 %, house over B's rating")
|
||||
STEPS = (800.0, 4000.0, 5500.0)
|
||||
|
||||
|
||||
def steps(t):
|
||||
return STEPS[min(int(t // 300), 2)]
|
||||
|
||||
|
||||
DR = run(steps, {B: DRAIN}, {"a": 15.0, "b": 60.0}, 900.0)
|
||||
DR_OLD = without_fix(lambda: run(steps, {B: DRAIN}, {"a": 15.0, "b": 60.0},
|
||||
900.0))
|
||||
for tag, (rows, c) in (("after", DR), ("before", DR_OLD)):
|
||||
print(f" {tag}: house 800 A/B {seg(rows, 60, 300)}, 4000 "
|
||||
f"{seg(rows, 360, 600)}, 5500 {seg(rows, 660, 900)}; A asked while "
|
||||
f"B not full: {a_before_b(rows)} cycles; UNMET "
|
||||
f"{unmet(rows, 0, 900)}")
|
||||
check("⭐ A (held) is never asked to give while B has room: every cycle that "
|
||||
"puts power on A has B at its full 2500 W",
|
||||
a_before_b(DR[0]) == 0 and DR[1].maints[1].phase == DRAIN)
|
||||
check("...house 4000: B rises from its 1000 W drain rate to 2500 W and A "
|
||||
"gives only the 1500 W rest (before: A 2500, B 1000)",
|
||||
seg(DR[0], 360, 600)[1] >= 2480 and seg(DR[0], 360, 600)[0] <= 1520
|
||||
and seg(DR_OLD[0], 360, 600)[0] >= 2480
|
||||
and seg(DR_OLD[0], 360, 600)[1] <= 1020)
|
||||
check("...house 800: B still drains at its 1000 W rate (the rest is "
|
||||
"exported, as before) and A gives nothing",
|
||||
all(cmd(r)["b"] >= 1000.0 and cmd(r)["a"] == 0.0
|
||||
for r in DR[0] if 60 <= r[0] < 300))
|
||||
check("...house 5500 (over both ratings): option A stands, A is drawn as a "
|
||||
"last resort once B is full, and nothing is left UNMET",
|
||||
seg(DR[0], 660, 900) == (2500, 2500) and unmet(DR[0], 0, 900) == 0)
|
||||
check("non-vacuous: before the fix A was asked while B had room",
|
||||
a_before_b(DR_OLD[0]) >= 100)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n2. the held battery reaches its cut-out (house 5500)")
|
||||
CO = run(5500.0, {B: DRAIN}, {"a": 11.0, "b": 60.0}, 1200.0)
|
||||
CO_OLD = without_fix(lambda: run(5500.0, {B: DRAIN}, {"a": 11.0, "b": 60.0},
|
||||
1200.0))
|
||||
|
||||
|
||||
def after_cut(rows, c):
|
||||
"""Rows once A reads its cut-out (its level follows its power)."""
|
||||
return [r for r in rows if c.levels[r[0]]["a"] <= CUT]
|
||||
|
||||
|
||||
_ac, _ac_old = after_cut(*CO), after_cut(*CO_OLD)
|
||||
print(f" after A's cut-out: B {seg(_ac, 0, 9e9)[1]} W over {len(_ac)} "
|
||||
f"cycles (before: {seg(_ac_old, 0, 9e9)[1]} W); A soc "
|
||||
f"{CO[1].inverters[0].soc:.2f} %")
|
||||
check("⭐ at its cut-out nothing is placed on A (0 W on every cycle), B "
|
||||
"gives its full 2500 W and nothing is left UNMET on the empty A",
|
||||
CO[1].inverters[0].soc <= CUT and len(_ac) >= 100
|
||||
and all(cmd(r)["a"] == 0.0 and cmd(r)["b"] == FULL for r in _ac)
|
||||
and unmet(CO[0], 600, 1200) == 0)
|
||||
check("non-vacuous: before the fix B stayed pinned under its rating on most "
|
||||
"of those cycles (the rig saw ~2422 W)",
|
||||
len(_ac_old) >= 100
|
||||
and sum(1 for r in _ac_old if cmd(r)["b"] < FULL) > len(_ac_old) / 2)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n3. HOLD across a quarter edge (A full holding, B held at 15 %)")
|
||||
EDGE = run(5500.0, {A: HOLD}, {"a": 99.0, "b": 15.0}, 1000.0, late=0.5)
|
||||
EDGE_OLD = without_fix(lambda: run(5500.0, {A: HOLD}, {"a": 99.0, "b": 15.0},
|
||||
1000.0, late=0.5))
|
||||
|
||||
|
||||
def at_edge(rows):
|
||||
return [(r[0], cmd(r)["a"], cmd(r)["b"]) for r in rows
|
||||
if QUARTER_S - 1 <= r[0] <= QUARTER_S + 1]
|
||||
|
||||
|
||||
print(f" edge after {at_edge(EDGE[0])}, before {at_edge(EDGE_OLD[0])}")
|
||||
check("⭐ the telegram at the edge comes late (0.5 s): B gives nothing on any "
|
||||
"cycle (the first cycle, before any quarter is measured, aside), A "
|
||||
"keeps giving and stays in its HOLD",
|
||||
all(cmd(r)["b"] == 0.0 for r in EDGE[0] if r[0] > 0)
|
||||
and all(a > 2000.0 for _t, a, _b in at_edge(EDGE[0]))
|
||||
and EDGE[1].maints[0].phase == HOLD)
|
||||
check("non-vacuous: before the fix B gave over 2000 W at the edge (F2)",
|
||||
any(b > 2000.0 for _t, _a, b in at_edge(EDGE_OLD[0])))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. idle, house 2000 W")
|
||||
ID = run(2000.0, {}, {"a": 15.0, "b": 60.0}, 300.0)
|
||||
ID_OLD = without_fix(lambda: run(2000.0, {}, {"a": 15.0, "b": 60.0}, 300.0))
|
||||
print(f" A held: after {seg(ID[0], 120, 300)}, before "
|
||||
f"{seg(ID_OLD[0], 120, 300)}")
|
||||
check("⭐ A held, B able: B carries the house alone; A is asked only on the "
|
||||
"cycles where the lagging B is already at its full command",
|
||||
a_before_b(ID[0]) == 0 and seg(ID[0], 120, 300)[0] == 0
|
||||
and seg(ID[0], 120, 300)[1] >= 1950)
|
||||
check("non-vacuous: before the fix the weights gave A a share",
|
||||
seg(ID_OLD[0], 120, 300)[0] > 50)
|
||||
BOTH = run(2000.0, {}, {"a": 15.0, "b": 14.0}, 300.0)
|
||||
BOTH_OLD = without_fix(lambda: run(2000.0, {}, {"a": 15.0, "b": 14.0}, 300.0))
|
||||
check("...both held: nothing to give first, the split is as before",
|
||||
[r[:3] for r in BOTH[0]] == [r[:3] for r in BOTH_OLD[0]])
|
||||
|
||||
|
||||
def held_back(socs, refused=(0, 0), live=(A, B)):
|
||||
c = ID[1]
|
||||
for inv, s, r in zip(c.inverters, socs, refused):
|
||||
inv.soc, inv.refused = s, r
|
||||
c.live_units = lambda: live
|
||||
try:
|
||||
return c._held_back()
|
||||
finally:
|
||||
del c.live_units
|
||||
for inv in c.inverters:
|
||||
inv.refused = 0
|
||||
|
||||
|
||||
check("...held back only while another can give: A held beside B able; "
|
||||
"nothing with B refusing to give, B dropped, or both under",
|
||||
held_back((15.0, 60.0)) == {A} and held_back((15.0, 60.0), (0, 1))
|
||||
== frozenset() and held_back((15.0, 60.0), live=(A,)) == frozenset()
|
||||
and held_back((15.0, 14.0)) == frozenset()
|
||||
and held_back((15.0, 60.0), (0, -1)) == {A})
|
||||
|
||||
# A's SoC READING flips 20/21 % across its 20 % reserve every 10 s, and B
|
||||
# follows its command faster (3 s) than A (10 s), as two different inverters.
|
||||
def _flip(u, t, level):
|
||||
return (20.0 + int(t // 10) % 2) if u == "a" else level
|
||||
|
||||
|
||||
def _a_jumps(rows, t0):
|
||||
rs = [r for r in rows if r[0] >= t0]
|
||||
return sum(1 for p, q in zip(rs, rs[1:])
|
||||
if abs(cmd(p)["a"] - cmd(q)["a"]) > 300.0)
|
||||
|
||||
|
||||
def _grid_rms(c, t0):
|
||||
g = [w + 10.0 for t, w in c.grid if t >= t0]
|
||||
return math.sqrt(sum(w * w for w in g) / len(g))
|
||||
|
||||
|
||||
_lags = {"a": 10.0, "b": 3.0}
|
||||
FL = run(2000.0, {}, {"a": 20.0, "b": 60.0}, 600.0, read=_flip, lags=_lags)
|
||||
_real_was = Controller.__dict__["_held_back"]
|
||||
|
||||
|
||||
def _no_hyst(self):
|
||||
self._held_was = frozenset()
|
||||
return _real_was(self)
|
||||
|
||||
|
||||
Controller._held_back = _no_hyst
|
||||
try:
|
||||
FL_OLD = run(2000.0, {}, {"a": 20.0, "b": 60.0}, 600.0, read=_flip,
|
||||
lags=_lags)
|
||||
finally:
|
||||
Controller._held_back = _real_was
|
||||
print(f" A's reading flipping 20/21 %: A jumps {_a_jumps(FL[0], 120)}, "
|
||||
f"grid rms {_grid_rms(FL[1], 120):.0f} W (no hysteresis: "
|
||||
f"{_a_jumps(FL_OLD[0], 120)}, {_grid_rms(FL_OLD[1], 120):.0f} W)")
|
||||
check("⭐ a SoC reading flipping across the reserve does not swap the split: "
|
||||
"A stays held back (0 W) and the grid stays near its target",
|
||||
_a_jumps(FL[0], 120) == 0 and seg(FL[0], 120, 600)[0] == 0
|
||||
and _grid_rms(FL[1], 120) < 30.0)
|
||||
check("non-vacuous: without the 1-point hysteresis the split swaps on "
|
||||
"every flip and the grid swings",
|
||||
_a_jumps(FL_OLD[0], 120) >= 20 and _grid_rms(FL_OLD[1], 120) > 100.0)
|
||||
REL = run(2000.0, {}, {"a": 20.0, "b": 60.0}, 300.0,
|
||||
read=lambda u, t, lv: (20.0 if t < 100 else 21.0 if t < 200
|
||||
else 22.0) if u == "a" else lv)
|
||||
check("...held back at 20 %, still at 21 %, released at 22 % (more than 1 "
|
||||
"point above its reserve)",
|
||||
seg(REL[0], 40, 100)[0] == 0 and seg(REL[0], 140, 200)[0] == 0
|
||||
and seg(REL[0], 240, 300)[0] > 500)
|
||||
ID[1]._held_was = frozenset({A, B})
|
||||
check("...a battery kept held back by the hysteresis is not one that can "
|
||||
"give: A at 20 % and B kept at 21 % hold nobody back",
|
||||
held_back((20.0, 21.0)) == frozenset())
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n5. the rules at their boundaries")
|
||||
|
||||
|
||||
def stub(names, held, live=None):
|
||||
"""A Controller stand-in for `_drain_rise()`, on SIMULATED units."""
|
||||
s = types.SimpleNamespace(
|
||||
inverters=[types.SimpleNamespace(name=n) for n in names],
|
||||
actuator_of=lambda src, inv=None: inv.name,
|
||||
live_units=lambda: tuple(live or names),
|
||||
_held_back=lambda: frozenset(held))
|
||||
return s
|
||||
|
||||
|
||||
def rise(names, held, target, drains, extra=(), live=None):
|
||||
"""`_drain_rise()` then the split: (claims kinds, shares)."""
|
||||
cl = [Claim.limit("supervised", P_SAFETY, -FULL, FULL, actuator=n)
|
||||
for n in names]
|
||||
cl += [Claim.set("maintenance", P_MAINTENANCE, w, DRAIN, actuator=n)
|
||||
for n, w in drains.items()]
|
||||
cl += list(extra)
|
||||
res = [MaintResult(DRAIN, True, drains[n], False, []) if n in drains
|
||||
else MaintResult(IDLE, False, None, False, []) for n in names]
|
||||
Controller._drain_rise(stub(names, held, live), cl, res)
|
||||
r = resolve(cl + [Claim.set("loop", 10, target)], units=tuple(names),
|
||||
live=set(live or names), reserve=held)
|
||||
kinds = {c.actuator: c.kind for c in cl if c.source == "maintenance"}
|
||||
return kinds, {u: round(v) for u, v in r.shares.items()}
|
||||
|
||||
|
||||
_n3 = rise(("x", "y", "z"), {"z"}, 1500.0, {"x": 1000.0})
|
||||
print(f" N=3, x draining 1000, y able, z held, 1500 W: {_n3[1]}")
|
||||
check("⭐ N=3: the draining battery keeps its drain rate as a floor (x >= "
|
||||
"1000 W) while sharing with the able one; the held one gives nothing",
|
||||
_n3[0] == {"x": "limit"} and _n3[1]["x"] >= 1000 and _n3[1]["z"] == 0
|
||||
and sum(_n3[1].values()) == 1500)
|
||||
_stop = rise((A, B), {A}, 3000.0, {B: 1000.0},
|
||||
(Claim.set("safety", P_SAFETY, 0.0, "stopped"),))
|
||||
check("⭐ a site stop decides alone: the drain stays a pin, nothing rises",
|
||||
_stop[0] == {B: "set"} and _stop[1] == {A: 0, B: 0})
|
||||
_hd = rise((A, B), {A}, 5000.0, {A: 1000.0})
|
||||
check("...a held battery's own drain stays a pin (it is not raised for the "
|
||||
"loop): A 1000 W, B 2500 W",
|
||||
_hd[0] == {A: "set"} and _hd[1] == {A: 1000, B: 2500})
|
||||
_nh = rise((A, B), set(), 3000.0, {B: 1000.0})
|
||||
check("...with nothing held the drain stays a pin, as before (SAFETY-78)",
|
||||
_nh[0] == {B: "set"} and _nh[1] == {A: 2000, B: 1000})
|
||||
_dead = rise((A, B), {A}, 3000.0, {B: 1000.0}, live=(A,))
|
||||
check("...a draining battery that is not live is not touched",
|
||||
_dead[0] == {B: "set"})
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n6. next_quarter()")
|
||||
T0 = rig.BASE
|
||||
|
||||
|
||||
def proj(elapsed, covered=1.0, held=3000.0, start=T0):
|
||||
return Projection(projected_w=2000.0, elapsed_w=1900.0, elapsed_s=elapsed,
|
||||
covered_frac=covered, complete=covered >= 1.0,
|
||||
block_start=start, held_w=held)
|
||||
|
||||
|
||||
_in = proj(899.0)
|
||||
_past = next_quarter(proj(900.4, covered=899.9 / 900.4), 30.0)
|
||||
check("⭐ inside its block a projection is unchanged (the same object)",
|
||||
next_quarter(_in, 30.0) is _in)
|
||||
check("⭐ past its end with a fresh held reading: the next quarter, "
|
||||
"projected from that reading",
|
||||
_past.block_start == T0 + timedelta(seconds=QUARTER_S)
|
||||
and abs(_past.elapsed_s - 0.4) < 1e-9 and _past.projected_w == 3000.0
|
||||
and _past.covered_frac == 1.0
|
||||
and peakguard.blindness(_past, 30.0, False) is None)
|
||||
_old = proj(960.0, covered=880.0 / 960.0)
|
||||
_edge29 = proj(901.0, covered=871.5 / 901.0) # 29.5 s uncovered
|
||||
_edge31 = proj(901.0, covered=870.5 / 901.0) # 30.5 s uncovered
|
||||
check("...the held reading is credited up to max_hold_s and no further "
|
||||
"(29.5 s uncovered: rolled; 30.5 s: unchanged)",
|
||||
next_quarter(_edge29, 30.0) is not _edge29
|
||||
and next_quarter(_edge31, 30.0) is _edge31)
|
||||
check("...a held reading too old to be credited, no block, or an export: "
|
||||
"unchanged, or projected at 0 W offtake",
|
||||
next_quarter(_old, 30.0) is _old
|
||||
and next_quarter(proj(950.0, start=None), 30.0).block_start is None
|
||||
and next_quarter(proj(900.5, held=-800.0), 30.0).projected_w == 0.0)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n7. N=1")
|
||||
for _name, _args in (("HOLD, late telegram at the edge",
|
||||
(5500.0, {A: HOLD}, {"a": 99.0}, 1000.0, 0.5)),
|
||||
("drain under the reserve, house 4000",
|
||||
(4000.0, {A: DRAIN}, {"a": 15.0}, 600.0, 0.5))):
|
||||
_new = run(*_args, n=1)
|
||||
_old = without_fix(lambda: run(*_args, n=1))
|
||||
print(f" {_name}: A at the edge "
|
||||
f"{[cmd(r)['a'] for r in _new[0] if 899 <= r[0] <= 901]}")
|
||||
check(f"⭐ N=1, {_name}: every row (claims, commands, the guard) is "
|
||||
"identical with and without the fix",
|
||||
_new[1].maints[0].phase == _args[1][A] and len(_new[0]) > 500
|
||||
and _new[0] == _old[0])
|
||||
_one = types.SimpleNamespace(inverters=[object()])
|
||||
_cl = [Claim.set("maintenance", P_MAINTENANCE, 1000.0, DRAIN)]
|
||||
check("⭐ at one inverter nothing is held back and no pin moves (the N=1 "
|
||||
"identity digests in test_safety78/79/83/84/86/87 stay pinned)",
|
||||
Controller._held_back(_one) == frozenset()
|
||||
and Controller._drain_rise(types.SimpleNamespace(
|
||||
inverters=[object()], _held_back=lambda: frozenset()), _cl,
|
||||
[MaintResult(DRAIN, True, 1000.0, False, [])]) is None
|
||||
and _cl[0].kind == "set")
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all SAFETY-91 checks passed")
|
||||
@@ -1,422 +0,0 @@
|
||||
"""Runnable check for SAFETY-93: the maintenance charge end hands back
|
||||
smoothly, with no grid charging at a high house. `python3 test_safety93.py`
|
||||
|
||||
At N=2, when battery A's maintenance charge ended, its watts stayed in the
|
||||
loop's site target and landed on B: B went 0 -> -1600 W in one cycle and
|
||||
charged from the grid with the house at 6000 W (SAFETY-85 rig test, check 4).
|
||||
Now the loop starts from what B stood at plus A's new command. Drives the
|
||||
REAL Controller on a lagging battery (10 s, 2 s meter, as on the rig).
|
||||
DECISIONS/SAFETY-93-charge-end.md.
|
||||
|
||||
1. The rig case: A charges 2000 W late in a quarter with the house at 6000 W,
|
||||
then its charge ends (HOLD).
|
||||
2. The same at a low house.
|
||||
3. The charge ends another way: a timeout (abort) and the battery switched
|
||||
Off.
|
||||
4. The charge ends while the guard has suspended it (A gives under the loop).
|
||||
5. N=1 is untouched; a missed poll on the end cycle; the rule at its
|
||||
boundaries.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import hashlib
|
||||
import logging
|
||||
import math
|
||||
import os
|
||||
import sys
|
||||
from datetime import timedelta
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety79_identity as s79 # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
from app import packmode # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.maintenance import (CHARGE_TIMEOUT_MIN, HOLD, IDLE, # noqa: E402
|
||||
MaintResult)
|
||||
from app.store import unit_key # noqa: E402
|
||||
from named_absence import first, present # noqa: E402
|
||||
|
||||
fails = []
|
||||
A = "inverter-a"
|
||||
SLEW = 400.0 # the rig's slew_w
|
||||
AIM = 3500 - 50 # peak_cap_w - peak_margin_w
|
||||
OPT0 = dict(s84.OPT)
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def lagging(fn, lag=10.0):
|
||||
"""plantsim's battery (800 W/s ramp, `lag` s first-order lag) at the
|
||||
live 2 s meter tick (test_safety85.py part 7)."""
|
||||
real_p, real_t = rig._Hass.power, rig.TICK
|
||||
|
||||
def power(self, u):
|
||||
st = self.__dict__.setdefault("_plant", {})
|
||||
a, tgt, tl = st.get(u, (0.0, 0.0, self.t))
|
||||
for _ in range(int(round((self.t - tl) / 0.1))):
|
||||
d = self.cmd[u] - tgt
|
||||
tgt += math.copysign(min(abs(d), 80.0), d)
|
||||
a += (tgt - a) * (1 - math.exp(-0.1 / lag))
|
||||
st[u] = (a, tgt, self.t)
|
||||
return float(round(a))
|
||||
rig._Hass.power, rig.TICK = power, 2.0
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
rig._Hass.power, rig.TICK = real_p, real_t
|
||||
|
||||
|
||||
def run(n, house, end, *, step=None, dur=None, store=None, extra=None,
|
||||
before=None):
|
||||
"""A charging in a cheap window from the first cycle (quarters start at
|
||||
0, 900, 1800 s); the house is 1200 W, then `house` from `step`; A reads
|
||||
99 % (its charge target) from `end`. Returns (rows, controller)."""
|
||||
step = end if step is None else step
|
||||
s84.OPT = dict(OPT0, peak_cap_w=3500)
|
||||
feed = s84.feed(True)
|
||||
|
||||
def both(c, t):
|
||||
if before is not None:
|
||||
before(c, t)
|
||||
feed(c, t)
|
||||
try:
|
||||
return lagging(lambda: s84.run(
|
||||
n, load=lambda t: house if t >= step else 1200.0, cheap=True,
|
||||
store=store or s79.store_charging(n),
|
||||
soc=lambda u, t: (99.0 if t >= end else 90.0) if u == "a"
|
||||
else 60.0, dur=dur or end + 300.0, before=both,
|
||||
extra=dict({"maintenance_hold_min": 600}, **(extra or {}))))
|
||||
finally:
|
||||
s84.OPT = OPT0
|
||||
|
||||
|
||||
def cmd(r):
|
||||
return dict(r[2])
|
||||
|
||||
|
||||
def moves(rows, u, lo, hi):
|
||||
"""The largest change in battery `u`'s command between cycles in
|
||||
(lo, hi]."""
|
||||
return max(abs(cmd(b)[u] - cmd(a)[u]) for a, b in zip(rows, rows[1:])
|
||||
if lo < b[0] <= hi)
|
||||
|
||||
|
||||
def charging_hi(rows, lo, hi, house_at):
|
||||
"""Cycles in [lo, hi] where a battery charges while the house is above
|
||||
the peak aim."""
|
||||
return sum(1 for r in rows if lo <= r[0] <= hi and house_at(r[0]) > AIM
|
||||
and min(cmd(r).values()) < 0.0)
|
||||
|
||||
|
||||
# None on a tree without the fix (f3e409c), where this file runs red.
|
||||
no_fix = getattr(Controller, "_reseed_charge_end", None)
|
||||
|
||||
|
||||
def without(fn):
|
||||
"""Run `fn` with the SAFETY-93 reseed taken out."""
|
||||
if no_fix is None:
|
||||
return fn()
|
||||
Controller._reseed_charge_end = lambda self, ended: None
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
Controller._reseed_charge_end = no_fix
|
||||
|
||||
|
||||
def phase_at(rows, t):
|
||||
return first((r[-1][3][0] for r in rows if r[0] == t), f"row {t}")
|
||||
|
||||
|
||||
def at(rows, t, u):
|
||||
"""Battery `u`'s command at `t` s."""
|
||||
r = first((r for r in rows if r[0] == t), f"row {t}")
|
||||
return dict(r[2])[u] if present(r) else r
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. the rig case: A charges 2000 W late in a quarter, house 6000 W")
|
||||
# House 1200 W until 1760 s, then 6000 W; the quarter (900-1800 s) has room,
|
||||
# so the charge stays at 2000 W. A is full at 1780 s. Graded to 1798 s: the
|
||||
# guard grades a new quarter from 1800 s.
|
||||
R1 = run(2, 6000.0, 1780.0, step=1760.0)
|
||||
R1_old = without(lambda: run(2, 6000.0, 1780.0, step=1760.0))
|
||||
|
||||
|
||||
def hi1(t):
|
||||
return 6000.0 if t >= 1760.0 else 1200.0
|
||||
|
||||
|
||||
for name, (rows, _c) in (("now", R1), ("without the fix", R1_old)):
|
||||
print(f" {name}: " + ", ".join(
|
||||
f"{r[0]:.0f}s A {cmd(r)['a']:.0f} B {cmd(r)['b']:.0f}"
|
||||
for r in rows if 1776 <= r[0] <= 1786))
|
||||
_r, _ = R1
|
||||
check("the case is the rig's: A charges 2000 W with the house at 6000 W the "
|
||||
"cycle before its charge ends, then holds",
|
||||
at(_r, 1778.0, "a") == -2000.0
|
||||
and phase_at(_r, 1778.0) == "charge" and phase_at(_r, 1780.0) == HOLD)
|
||||
check("⭐ no battery charges from the grid after the charge ends (house above "
|
||||
"the aim)", charging_hi(_r, 1780, 1798, hi1) == 0)
|
||||
check("⭐ B moves at most one slew step a cycle across the charge end, and A "
|
||||
"after its HOLD pin", moves(_r, "b", 1776, 1798) <= SLEW
|
||||
and moves(_r, "a", 1780, 1798) <= SLEW)
|
||||
check("...and B gives toward the house at once (+400 W at the end cycle)",
|
||||
at(_r, 1780.0, "b") == SLEW)
|
||||
check("non-vacuous: without the fix B jumps 0 -> -1600 W and charges from "
|
||||
"the grid for 4 cycles", moves(R1_old[0], "b", 1776, 1798) >= 1600
|
||||
and charging_hi(R1_old[0], 1780, 1798, hi1) >= 4)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n2. the same at a low house")
|
||||
R2 = run(2, 1200.0, 1300.0)
|
||||
R2_old = without(lambda: run(2, 1200.0, 1300.0))
|
||||
print(f" B's largest move: {moves(R2[0], 'b', 1296, 1600):.0f} W, without "
|
||||
f"the fix {moves(R2_old[0], 'b', 1296, 1600):.0f} W; B's least "
|
||||
f"command after the end "
|
||||
f"{min(cmd(r)['b'] for r in R2[0] if r[0] >= 1300):.0f}"
|
||||
f" W, without {min(cmd(r)['b'] for r in R2_old[0] if r[0] >= 1300):.0f}"
|
||||
" W")
|
||||
check("⭐ house 1200 W: B moves at most one slew step a cycle and never "
|
||||
"charges from the grid after A's charge ends",
|
||||
moves(R2[0], "b", 1296, 1600) <= SLEW
|
||||
and min(cmd(r)["b"] for r in R2[0] if r[0] >= 1300) >= 0.0)
|
||||
check("non-vacuous: without the fix B jumps to -1600 W (2800 W from the grid)",
|
||||
min(cmd(r)["b"] for r in R2_old[0] if r[0] >= 1300) <= -1600.0)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n3. the charge ends another way")
|
||||
|
||||
|
||||
def timed_out(end):
|
||||
"""A store whose charge passes CHARGE_TIMEOUT_MIN at `end` s."""
|
||||
s = s79.store_charging(2)
|
||||
s.data[unit_key(A, "phase_started")] = (
|
||||
rig.BASE + timedelta(seconds=end - CHARGE_TIMEOUT_MIN * 60 - 1)
|
||||
).isoformat()
|
||||
return s
|
||||
|
||||
|
||||
def b_done():
|
||||
"""A charging; B finished its monthly cycle, so it starts none here."""
|
||||
s = s79.store_charging(2)
|
||||
s.data[unit_key("inverter-b", "last_completed")] = rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
def switch_off(at):
|
||||
"""Battery A switched Off at `at` s (OPT-11 modes on)."""
|
||||
def before(c, t):
|
||||
if t >= at:
|
||||
c.store.data[unit_key(A, packmode.USE_KEY)] = False
|
||||
return before
|
||||
|
||||
|
||||
ENDS = {
|
||||
"timeout": lambda: run(2, 6000.0, 9999.0, step=1760.0, dur=2080.0,
|
||||
store=timed_out(1780.0)),
|
||||
"Off": lambda: run(2, 6000.0, 9999.0, step=1760.0, dur=2080.0,
|
||||
store=b_done(), before=switch_off(1780.0),
|
||||
extra={"battery_modes_enabled": True}),
|
||||
}
|
||||
for k, fn in ENDS.items():
|
||||
rows, c = fn()
|
||||
old = without(fn)[0]
|
||||
print(f" {k}: A {[cmd(r)['a'] for r in rows if 1776 <= r[0] <= 1784]}"
|
||||
f" B {[cmd(r)['b'] for r in rows if 1776 <= r[0] <= 1784]}; "
|
||||
f"without the fix B "
|
||||
f"{[cmd(r)['b'] for r in old if 1776 <= r[0] <= 1784]}")
|
||||
check(f"{k}: the charge ends at 1780 s",
|
||||
phase_at(rows, 1778.0) == "charge"
|
||||
and phase_at(rows, 1780.0) == IDLE)
|
||||
check(f"⭐ {k}: no battery charges from the grid after it, and B moves at "
|
||||
f"most one slew step a cycle",
|
||||
charging_hi(rows, 1780, 1798, hi1) == 0
|
||||
and moves(rows, "b", 1776, 1798) <= SLEW)
|
||||
check(f"non-vacuous ({k}): without the fix B jumps to -1600 W, from "
|
||||
f"the grid", at(old, 1780.0, "b") == -1600.0
|
||||
and charging_hi(old, 1780, 1798, hi1) >= 1)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. the charge ends while the guard has suspended it")
|
||||
# House 6000 W from 1500 s: the guard suspends the shaping, the loop has both
|
||||
# batteries give. A is full at 1530 s; its HOLD pin takes it to 0 W.
|
||||
R4 = run(2, 6000.0, 1530.0, step=1500.0)
|
||||
R4_old = without(lambda: run(2, 6000.0, 1530.0, step=1500.0))
|
||||
_a4 = at(R4[0], 1528.0, "a")
|
||||
print(f" A gave {_a4:.0f} W before its HOLD; B's largest move "
|
||||
f"{moves(R4[0], 'b', 1526, 1798):.0f} W, without the fix "
|
||||
f"{moves(R4_old[0], 'b', 1526, 1798):.0f} W")
|
||||
check("A gives under the loop before its charge ends",
|
||||
present(_a4) and _a4 > SLEW and R4[1].maints[0].phase == HOLD)
|
||||
check("⭐ B takes A's share at one slew step a cycle (A's own give stops "
|
||||
"with its HOLD pin, as before)", moves(R4[0], "b", 1526, 1798) <= SLEW
|
||||
and charging_hi(R4[0], 1530, 1798, lambda t: 6000.0) == 0)
|
||||
check("non-vacuous: without the fix B jumps more than a slew step",
|
||||
moves(R4_old[0], "b", 1526, 1798) > SLEW)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n5. N=1 is untouched; a missed poll; the rule at its boundaries")
|
||||
|
||||
|
||||
def digest(rows):
|
||||
return hashlib.sha256(repr(rows).encode()).hexdigest()
|
||||
|
||||
|
||||
_n1 = [digest(run(1, h, e, step=s)[0]) for h, e, s in
|
||||
((6000.0, 1780.0, 1760.0), (1200.0, 1300.0, None))]
|
||||
_n1_old = [digest(without(lambda: run(1, h, e, step=s))[0]) for h, e, s in
|
||||
((6000.0, 1780.0, 1760.0), (1200.0, 1300.0, None))]
|
||||
check("⭐ N=1, the charge ending at a high and a low house: every row "
|
||||
"byte-identical with and without the reseed", _n1 == _n1_old)
|
||||
|
||||
if no_fix is None:
|
||||
print(f"\n{len(fails)} FAILED (no _reseed_charge_end): " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
|
||||
|
||||
def missed_poll(at_t):
|
||||
"""Battery B's power reading is missing on the cycle at `at_t` s."""
|
||||
def before(c, t):
|
||||
if not getattr(c.hass, "_s93", False):
|
||||
read = c.hass.number
|
||||
|
||||
async def number(e, invert=False):
|
||||
if e == "sensor.batt_b" and c.hass.t == at_t:
|
||||
return None
|
||||
return await read(e, invert)
|
||||
c.hass.number, c.hass._s93 = number, True
|
||||
return before
|
||||
|
||||
|
||||
R6 = run(2, 6000.0, 1780.0, step=1760.0, before=missed_poll(1780.0))
|
||||
R6_old = without(lambda: run(2, 6000.0, 1780.0, step=1760.0,
|
||||
before=missed_poll(1780.0)))
|
||||
print(f" a missed poll on the end cycle: B "
|
||||
f"{[cmd(r)['b'] for r in R6[0] if 1778 <= r[0] <= 1786]}, without "
|
||||
f"the fix {[cmd(r)['b'] for r in R6_old[0] if 1778 <= r[0] <= 1786]}")
|
||||
check("a missed poll on the cycle the charge ends: the loop holds that cycle",
|
||||
phase_at(R6[0], 1780.0) == HOLD
|
||||
and "inputs missing" in str(first(r[6] for r in R6[0] if r[0] == 1780.0)))
|
||||
check("⭐ ...and the end still reaches the loop on the next cycle: no grid "
|
||||
"charge (A's charge stands through the held cycle), one slew step a "
|
||||
"cycle", charging_hi(R6[0], 1782, 1798, hi1) == 0
|
||||
and moves(R6[0], "b", 1776, 1798) <= SLEW)
|
||||
check("non-vacuous: without the fix B charges from the grid",
|
||||
charging_hi(R6_old[0], 1782, 1798, hi1) >= 1)
|
||||
_c = R1[1]
|
||||
|
||||
|
||||
def reseeded(target, shares, res, ended=frozenset({A})):
|
||||
"""`_reseed_charge_end` on the rig's controller, A's charge ended and
|
||||
its result `res`: (target, i_w)."""
|
||||
_c.target, _c.i_w, _c._charge_ended = target, 123.0, ended
|
||||
for inv in _c.inverters:
|
||||
inv.target = shares[inv.name[-1]]
|
||||
_c._reseed_charge_end([res, _free])
|
||||
return _c.target, _c.i_w
|
||||
|
||||
|
||||
_pin = MaintResult(HOLD, True, 0.0, False, [])
|
||||
_free = MaintResult(IDLE, False, None, False, [])
|
||||
check("a HOLD pin: the start is B's command plus the pin, integrator with it",
|
||||
reseeded(-2000.0, {"a": -2000.0, "b": 0.0}, _pin) == (0.0, 0.0)
|
||||
and reseeded(2770.0, {"a": 1385.0, "b": 1385.0}, _pin)
|
||||
== (1385.0, 1385.0) and _c._charge_ended == frozenset())
|
||||
check("a free battery: its charge leaves the start, its discharge stays",
|
||||
reseeded(-2000.0, {"a": -2000.0, "b": 0.0}, _free) == (0.0, 0.0)
|
||||
and reseeded(2770.0, {"a": 1385.0, "b": 1385.0}, _free)
|
||||
== (2770.0, 2770.0))
|
||||
check("no charge ended: nothing moves (the integrator either)",
|
||||
reseeded(-2000.0, {"a": -2000.0, "b": 0.0}, _pin, frozenset())
|
||||
== (-2000.0, 123.0))
|
||||
_n1c = run(1, 6000.0, 1780.0, step=1760.0)[1]
|
||||
_n1c.target, _n1c.i_w = -2000.0, 5.0
|
||||
_n1c.inverters[0].target, _n1c._charge_ended = -2000.0, frozenset({A})
|
||||
_n1c._reseed_charge_end([_pin])
|
||||
check("N=1: nothing moves", (_n1c.target, _n1c.i_w) == (-2000.0, 5.0))
|
||||
_seen = []
|
||||
|
||||
|
||||
def _spy(self, maint_results):
|
||||
_seen.append(sorted(self._charge_ended))
|
||||
return no_fix(self, maint_results)
|
||||
|
||||
|
||||
Controller._reseed_charge_end = _spy
|
||||
try:
|
||||
run(2, 6000.0, 1780.0, step=1760.0, dur=2400.0,
|
||||
extra={"maintenance_hold_min": 5})
|
||||
finally:
|
||||
Controller._reseed_charge_end = no_fix
|
||||
check("it fires once, at the charge end: not at the HOLD end or on any "
|
||||
"other cycle", [x for x in _seen if x] == [[A]]
|
||||
and len(_seen) > 300)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n6. A still in CHARGE but no longer placed: stale link, refusal")
|
||||
|
||||
|
||||
def link_drop(at):
|
||||
"""A's writes rejected from `at` s, so it is dropped as a stale link."""
|
||||
def before(c, t):
|
||||
a = c.inverters[0]
|
||||
if t >= at and a.rejected_since is None:
|
||||
a.rejected_since = rig.BASE + timedelta(seconds=at)
|
||||
return before
|
||||
|
||||
|
||||
def refuses(at):
|
||||
"""A stops charging from `at` s (reads 0 W); SAFETY-73 drops it."""
|
||||
def before(c, t):
|
||||
if not getattr(c.hass, "_s93r", False):
|
||||
real = c.hass.power
|
||||
|
||||
def power(u):
|
||||
p = real(u)
|
||||
return 0.0 if u == "a" and c.hass.t >= at and p < 0 else p
|
||||
c.hass.power, c.hass._s93r = power, True
|
||||
return before
|
||||
|
||||
|
||||
for k, hook in (("stale link", link_drop), ("refusal", refuses)):
|
||||
def fn(hook=hook):
|
||||
return run(2, 1200.0, 9999.0, dur=1500.0, before=hook(1300.0))
|
||||
rows, _c6 = fn()
|
||||
old = without(fn)[0]
|
||||
drop = first((r[0] for r in rows if r[0] >= 1300
|
||||
and "dropped inverter-a" in str(r[7])), "A dropped")
|
||||
print(f" {k}: A dropped at {drop:.0f} s; B "
|
||||
f"{[cmd(r)['b'] for r in rows if drop - 2 <= r[0] <= drop + 4]}, "
|
||||
f"without the fix {[cmd(r)['b'] for r in old if drop - 2 <= r[0] <= drop + 4]}")
|
||||
check(f"⭐ {k}: A is dropped while still in CHARGE, and B never charges "
|
||||
f"from the grid and moves at most one slew step a cycle",
|
||||
phase_at(rows, drop) == "charge"
|
||||
and min(cmd(r)["b"] for r in rows if r[0] >= 1300) >= 0.0
|
||||
and moves(rows, "b", 1296, 1500) <= SLEW)
|
||||
check(f"non-vacuous ({k}): without the fix B jumps to -1600 W",
|
||||
min(cmd(r)["b"] for r in old if r[0] >= 1300) <= -1600.0)
|
||||
|
||||
_seen.clear()
|
||||
Controller._reseed_charge_end = _spy
|
||||
try:
|
||||
run(2, 6000.0, 1530.0, step=1500.0)
|
||||
finally:
|
||||
Controller._reseed_charge_end = no_fix
|
||||
check("the guard suspending the charge is no end: it fires once, at the HOLD",
|
||||
[x for x in _seen if x] == [[A]])
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all SAFETY-93 checks passed")
|
||||
@@ -1631,10 +1631,7 @@ def _sign_site(hass, store=None, **over):
|
||||
_P(), stop=asyncio.Event())
|
||||
b = Inverter("inverter-b", setpoint_entity="number.sp_b",
|
||||
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b",
|
||||
max_w=B_RATING_HYPOTHESIS, store=c.store,
|
||||
# SAFETY-91: a cut-out, as rule 8 requires; without one B is
|
||||
# held back at its reserve and gets no share to reverse.
|
||||
bms_soc_floor=c.inverters[0].bms_soc_floor)
|
||||
max_w=B_RATING_HYPOTHESIS, store=c.store)
|
||||
b.dev_min, b.dev_max = -B_RATING_HYPOTHESIS, B_RATING_HYPOTHESIS
|
||||
c.inverters.append(b)
|
||||
c.auto = True
|
||||
|
||||
Reference in New Issue
Block a user