Claude f13dab1407 Release 0.14.0: changelog review fixes
checks / unit (pull_request) Successful in 26m57s
infra-pin / fresh (pull_request) Successful in 1s
Slew step not one house's 400 W; three two-inverter known issues, not
four; commissioning reference covers a new install; SoC example holds
for decimal sensors; SAFETY-95 states the jump, not the export.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 11:01:44 +02:00
glenn schrooyenandClaude Opus 5.5 b307db1049 Release 0.14.0: version bump and changelog
checks / unit (pull_request) Successful in 27m2s
infra-pin / fresh (pull_request) Successful in 2s
Two inverters are now supported for maintenance and the peak guard
(SAFETY-91, SAFETY-93). No option changes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 10:30:25 +02:00
admin e51e3e02b2 Merge pull request 'CI-13: infra-pin to admin/goodwe 0c04488 (FW-05, WITNESS-08)' (#168) from ci-13-infra-pin-0c04488 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-10-03 10:27:02 +02:00
admin 8b9680fc35 Merge pull request 'Deploy 0.13.0 to master' (#166) from deploy-0.13.0 into master
Reviewed-on: #166
2026-10-02 15:26:46 +02:00
admin 3ce18708b6 PKG-18: ship 0.12.0 to master, so TEL-12's pv_entities can reach an installed 0.11.0 (#118) 2026-09-24 23:22:34 +02:00
adminandClaude Opus 5 78acb558ff PKG-17: ship 0.11.0 to master, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1 (#115)
master is what the Home Assistant Supervisor clones, and the Supervisor
compares config.yaml version strings - so 0.11.0 could not be offered to an
installed 0.10.1 without this bump reaching master.

Carries SAFETY-56 (#112), TEL-11 (#113), the CI-9 follow-up (#102) and SEC-2's
docs/RELEASE.md (#108), by way of the 0.11.0 cut (#114).

NOT A FAST-FORWARD. master was not an ancestor of release/1.0: 0f14c2a, the
pre-SEC-2 direct push, exists only on master. Its tree is the same object as
the merge base b0b24e5 (c1fef26), so it carries no content delta, and
`git merge-tree --write-tree` over the two branches returns a tree bit-identical
to cccb2fa's own (6670502). This merge commit therefore contributes exactly
release/1.0's tree - master synthesises nothing.

Reviewed as the release decision, not a re-review of content. Verified from the
remote: slug goodwe_controller and every identity key unchanged (cross-checked
against the live box's Supervisor export), version 0.10.1 -> 0.11.0, and the
green is this PR's own - run 828 / job 1953, path checks.yml@refs/pull/115/head,
PRNUM 115, GRADED refs/pull/115/head merged into master, run_attempt 1, 31 test
files all passing in 8m01s of real work.

predeploy_check.py re-run against the owner's current options (exported
2026-09-24 20:02, 75 keys, pv_entity unset): CLEARED, exit 0. That retires the
stale-2026-09-07-export warning in the pull request body. Option surface
75 -> 76 with only pv_entity added, str? defaulting to "", no key removed, no
default moved, no rule added to validate.py - no SystemExit(78) on this hop.

Merging is not installing. No tag is cut here and `ha store reload` /
`ha addons update` have not been run.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 20:28:35 +02:00
glenn schrooyenandClaude Opus 5 0f14c2a5de PKG-16: ship 0.10.1 to master, so the Supervisor can offer SAFETY-57's fix
master is what Home Assistant clones. SAFETY-57 fixed a deadlock that parked
the reference install's battery for ~13 minutes while the site exported
2.4 kW, and the Supervisor compares config.yaml version strings - so the fix
could not reach an installed 0.10.0 without this bump reaching master.

Brings SAFETY-57 (#104) and the 0.10.1 cut (#105). master was a strict
ancestor; no conflict was possible.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-22 15:54:29 +02:00
2 changed files with 38 additions and 1 deletions
+37
View File
@@ -1,5 +1,42 @@
# Changelog
## 0.14.0
**A minor bump: new behaviour with two inverters, and no option changes.**
No option was added, removed or renamed, and no default changed (83
options). Options that start 0.13.0 also start 0.14.0. With one inverter,
control is the same as in 0.13.0.
⭐ **Two inverters are now supported** for the monthly maintenance (drain,
charge, hold) and the peak guard. To add a second inverter, follow
`docs/commissioning-b.md` in the `admin/goodwe` repo. Its Stage 5, where the
add-on takes control of it, needs 0.14.0. Read the known issues below first:
three of them are about two inverters.
Contents of this release, in merge order since 0.13.0 (`8c438ab`):
| | |
|---|---|
| `f3e409c` | Two inverters: a battery at or under its peak reserve gives last, after the others give their full power. It is freed again above reserve + 1 point (e.g. above 21 % for a 20 % reserve). At a quarter's edge the peak guard no longer drops out for a second ([[SAFETY-91]]) |
| `858f77c` | Two inverters: when a maintenance charge ends, for any reason, the other battery no longer starts charging from the grid; control hands over in small steps ([[SAFETY-93]]) |
| `e51e3e0` | CI tests against a newer `admin/goodwe` (CI only) ([[CI-13]]) |
### Known issues
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
- A healthy battery that turns from charging to giving can be held at 0 W for up to 15 min ([[SAFETY-94]]).
- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]).
- Two inverters: if one battery's drain stops early (e.g. switched Off), the other battery can jump to about 1.6 kW at once, and the surplus goes to the grid ([[SAFETY-95]]).
- Two inverters: after one battery's link drops, control can stall until a safety stop ([[SAFETY-96]]).
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
### If you are crossing from a version older than 0.10.0
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
bare options (`jq '.data.options'`) first.
## 0.13.0
**A minor bump: new behaviour, a new add-on page (Home, Settings, Batteries,
+1 -1
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller
version: "0.13.0"
version: "0.14.0"
slug: goodwe_controller
description: >-
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart