@@ -1,2 +1,2 @@
|
||||
# The admin/goodwe commit CI tests against. Bump: set to the full SHA of admin/goodwe release/1.0 HEAD (README.md, "CI and the infra pin").
|
||||
76898164b56190f0aa6f7a15be9ce6302c958ce5
|
||||
7081df4276ad3cf788355b97a3b3f40ea28d72bd
|
||||
|
||||
@@ -6,7 +6,7 @@ This applies to everything a home owner or installer reads: notifications, phone
|
||||
- **Title**: at most 5 everyday words. It says what is wrong ("Meter reading may be stuck"). No "GoodWe:" prefix, no full stop.
|
||||
- **Body**: **one sentence** of at most 25 words, saying what happened and what to do. A **red alarm** may use up to **3 sentences** (70 words, each sentence at most 30 words), so that no action a person must take is lost.
|
||||
- **Details**: the last line links to the add-on documentation and names the section with the rest: `Details: add-on documentation, section "<title>" under Notifications.` Background, figures, reason codes and history go there or into the log, never into the body.
|
||||
- **Status row**: at most 15 words. **Banner**: at most 12 words. **Refusal**: at most 30 words, naming the setting by its label. **Option name**: at most 6 words, not counting the group prefix. **Option description**: at most 30 words. Where a value comes from belongs in DOCS.md.
|
||||
- **Status row**: one sentence of at most 15 words. A **red** row may use up to 3 sentences (30 words), like a red alarm. It shows the live numbers the reader acts on and never an HA entity id. **Banner**: at most 12 words. **Refusal**: at most 30 words, naming the setting by its label. **Option name**: at most 6 words, not counting the group prefix. **Option description**: at most 30 words. Where a value comes from belongs in DOCS.md.
|
||||
- **Log line** (WARNING/ERROR): one line, at most 25 words. The reasoning goes on a DEBUG line. Log lines stay in English and are not translated.
|
||||
- **Sentences**: one idea each, active voice, present tense, with nothing nested in brackets and no semicolons (a semicolon is a second sentence in disguise). These translate well into Dutch and French.
|
||||
|
||||
@@ -26,22 +26,29 @@ Severity is shown by the title and the colour, never by CAPITALS or by words lik
|
||||
A rewrite never changes an alarm's severity, `notification_id` or cadence.
|
||||
|
||||
## 4. Words - the same word for the same thing everywhere
|
||||
A setting is named by its label in `translations/en.yaml`, in quotes when it sits mid-sentence (“Inverter rating”). The words below match those labels. If a label changes, change it here and in `app/messages.py` in the same change.
|
||||
|
||||
| Say | Not |
|
||||
|---|---|
|
||||
| the add-on (who decides), control (what it does: "start control", "Control: last ran …") | controller, loop, planner |
|
||||
| battery | pack, BMS pack |
|
||||
| inverter, or its name | unit, device, actuator |
|
||||
| controller | loop, planner |
|
||||
| meter | P1 feed, telegram |
|
||||
| peak limit / this month's peak | ceiling, capaciteitstarief, billed quarter |
|
||||
| 15-minute period | quarter |
|
||||
| battery level | SoC, state of charge |
|
||||
| cut-out level | BMS floor, `bms_soc_floor` |
|
||||
| peak reserve | `peak_soc_floor`, EMS floor |
|
||||
| inverter rating | `max_w`, rail |
|
||||
| battery level (setting: “Battery level entity”) | SoC, state of charge, charge level |
|
||||
| battery cut-out level, or cut-out level next to "battery" (setting: “Battery cut-out level”) | BMS floor, `bms_soc_floor` |
|
||||
| peak reserve (setting: “Peak reserve”) | `peak_soc_floor`, EMS floor, "peak guard will not discharge below" |
|
||||
| “Inverter rating” (the setting) | `max_w`, rail, inverter rating as a fact about the hardware |
|
||||
| solar production, solar entity (settings: “Solar production entity”, “Solar production entities, per inverter”, “Reversed-sign solar entities”) | PV, reversed-sign list, single sensor setting |
|
||||
| “Where the meter reading comes from” | meter source |
|
||||
| “Grid power entity”; entity for any Home Assistant sensor a setting points at | grid power sensor, sensor setting |
|
||||
| draw the battery down, give power | discharge, discharging |
|
||||
| control is stopped / every inverter is set to 0 W | failsafe, trip, latch, parked |
|
||||
| safety stop (a stop that only starting control clears) | failsafe latch |
|
||||
| software fault | BUG SIGNAL |
|
||||
| control board | master, ESP32 |
|
||||
| shadow mode | a mode that makes every decision but commands 0 W. The name is kept. |
|
||||
| shadow mode | a mode that makes every decision but commands 0 W. The name is kept. In shadow mode a text says what the add-on **would** send, never that it sent it. |
|
||||
|
||||
**Banned in titles and bodies** (the test fails on them): SAFETY-/TARIFF-/TEL-/CFG-/FW-/HW-nn and other card ids, integrator, anti-windup, windup, clamp, clamped, saturated, BUG SIGNAL, latch, latched, arbiter, allocator, register, `0x…`, layer 1/2/3, heartbeat, watchdog, telegram, ACK, CRC, OTA, Modbus, planner, `§n`, file names, IP addresses, option keys in snake_case, **HA entity ids**, and runs of 2 or more CAPITALISED words.
|
||||
|
||||
|
||||
@@ -357,3 +357,5 @@ the bump is PKG's call. The material an entry needs is this file.
|
||||
|
||||
The option surface moves **76 keys → 77**, one new optional key, `pv_entities`,
|
||||
empty on every install that does not set it.
|
||||
|
||||
**Superseded in part (UX-08, 2026-09-27):** the PV status rows no longer read 0.11.0's sentences at one entity. The owner ruled out entity ids on status rows, so 2/5 now holds for the control document only. See `UX-08-short-notifications.md`, phase 2b item 3.
|
||||
|
||||
@@ -12,3 +12,26 @@ The owner decided on 2026-09-27: a title of at most about 5 everyday words and a
|
||||
5. **SAFETY-32 at a roster of one.** The body no longer ends in a separate "WHICH PACK" paragraph. The pack's name is part of the first sentence ("The battery of inverter-b …"), and at a roster of one that is the only difference.
|
||||
6. **Dropped as background, now in DOCS:** "charging stays blocked" (peak reserve), "why no other guard fired" (circulating power, not delivering), and the saturation-freeze distinction (over-rating). "The meter cannot see this" stays in the circulating-power card, as the owner asked.
|
||||
7. **The Details link** opens the add-on's documentation page (`/hassio/addon/<slug>/documentation`, with the slug taken from the container hostname) and names the section. A `#heading` anchor was not used because nobody has checked that Home Assistant's documentation tab renders heading ids; if it does, adding one is a one-line change. Outside an add-on container it names the section without a link.
|
||||
|
||||
# Phase 2b: status rows and page banners
|
||||
|
||||
Every row of the Commissioning list and every banner is now in `app/messages.py` (`row_*`, `banner_*`), and `test_messages.py` checks a rendering of each. The row and banner kinds are gone from `ux08_allowlist.txt` (200 → 168 entries). DOCS.md "Status page" explains the rows. **Unchanged:** every row's colour (ok / warn / bad), which rows show when, and the banner cascade order.
|
||||
|
||||
## Where a choice was made
|
||||
1. **A red row may use 3 sentences (30 words).** STYLE.md gave rows 15 words; the owner allows red safety states 3 sentences. A red row needs room for what happened, the state (0 W) and how it clears. STYLE.md now says so, and the test applies it by colour.
|
||||
2. **Figures left the rows, not the product.** The reason texts (freeze, sign, circulating, delivery, peak guard) carry reason codes and limits; they stay on the ERROR/WARNING log line and the event list, as before. Rows keep the numbers a reader acts on: the stall age and the 0 W deadline, the meter age and limit, asked and sent for an over-rating, the peak limit, and "opposite for 12 of 60 seconds" while a check counts. So 2a item 2 ("also on the status row") no longer holds, and DOCS.md says "in the add-on log".
|
||||
3. **No entity id on any row**, even the green ones that used to print `sensor.x = 54`. The sensor rows name the setting (*Battery power for inverter-b*). Solar sources are numbered in the order of the settings list (*source 2 of 3*, *entry 1 of the reversed-sign list*). This retires TEL-12's rule that a one-entity site reads 0.11.0's sentence byte for byte. A `tools/tel11_pv_trace.py --compare` against a pre-UX-08 tree therefore shows the PV rows as changed telemetry, and the control documents stay equal. The per-source watts and units left the multi-source row. The total, the count and which source is missing remain.
|
||||
4. **UX-07 item 1.** `ClampWatchdog` now also counts `over_rating` and `bound` separately. After an episode, each count shows under its own alarm's title ("Power request too high: 2 times since start, not now", "Battery is not keeping up: …"). A site with both gets two amber rows where it had one.
|
||||
5. **The "Not ready" banner** is the first red row's own `banner`, or else its first sentence. The peak-reserve and over-rating rows set `banner` to their notification title. The three trips keep their own banner branches, reworded (e.g. "Inverters worked against each other. Every inverter is set to 0 W.").
|
||||
6. **How a latch clears stays on the row**, shortened: "Only starting control clears this", "A restart does not clear this", "only stopping and starting control clears this" (not delivering). SAFETY-25's sentence stays on the peak-reserve row.
|
||||
7. **Rows got an `id`** (`meter_frozen`, `direction`, `pv`, …), so tests find a row by what it is, not by its words. The page ignores it.
|
||||
8. **Left for later:** texts that rows embed from other modules and that were not flagged as rows (the month-peak line, `peakguard.explain()`, the liveness and stale notes, `shadow.banner()`). The month-peak row only lost its semicolons.
|
||||
|
||||
# UX-09: fixes after the phase 2a test
|
||||
|
||||
1. **The Details link follows the Home Assistant version.** HA 2026.2 added the built-in `app` panel (core #157554, frontend #28245), whose add-on pages are `/config/app/<slug>/documentation`. 2026.5 stopped registering the `hassio` panel, so `/hassio/addon/<slug>/documentation` is a 404 there (TEST-23, HA 2026.9.1). 2026.1 and older have only the old path. The one path valid on both, `/_my_redirect/supervisor_addon?addon=<slug>`, opens the Info tab, not Documentation. So the add-on reads its slug (`GET /addons/self/info`) and the HA version (`GET /info`) at start, and picks the path. An unknown version gets the current path. The hostname stays as a fallback for the slug. Phase 2a item 7 is replaced by this.
|
||||
2. **Shadow mode says "would".** The over-rating alarm and row said "sent X W" while 0 W was on the wire, and the peak alarm said "the battery is giving all it can". Both now take `shadow=`, and in shadow mode say what would have been sent and that the inverters stay at 0 W. Severity, id and cadence do not change with the mode.
|
||||
3. **"Controller" is gone from texts.** "The add-on" names who decides, and "control" names what it does, as in the existing "start control". The add-on is what the reader sees in Home Assistant, and "controller" was easy to confuse with the control board.
|
||||
4. **One term per setting, matching its label.** Four labels changed instead of the texts, because the texts' words were plainer: “Peak reserve (%)” (was "Peak guard will not discharge below"), “Battery level entity (%)” (was "Battery charge level"), and “Solar production entity / entities, per inverter / Reversed-sign solar entities” (was "PV …"). The Dutch labels already said "Zonneproductie". Option descriptions are phase 2c and were not changed, so some still say "PV".
|
||||
5. **The shadow banner and the inverter notes** are now `messages.banner_shadow()` and `row_no_setpoint` / `row_not_controllable` / `row_commands_refused`, so `test_messages.py` checks them. The red shadow banner no longer lists the latches, because 12 words cannot carry them. It says a safety stop stays on, and each latch keeps its own red row, which names it and says how it clears. The colour of a liveness row now comes from `is_live()`, not from matching "NOT COMMANDABLE" in the text.
|
||||
6. **DOCS "Notifications" and "Status page"** are written for a home owner, and the card ids, keys and log detail moved to a "For installers" part of each.
|
||||
|
||||
+212
-106
@@ -477,7 +477,7 @@ History recorded before you set it keeps the old sign. See
|
||||
The add-on reads your entity's own `unit_of_measurement` and converts: `mW`,
|
||||
`W`, `kW`, `MW`, `GW`, `TW` — Home Assistant's own power units. A sensor with
|
||||
**no** unit, or with a unit that is not one of those, is **refused**, and the
|
||||
status page says which entity and which unit. That is deliberate: there is no
|
||||
status page says so (*the sensor has no unit*). That is deliberate: there is no
|
||||
magnitude test that can separate 30 W of dusk from 30 kW of noon, so a guess
|
||||
here would be a silent factor of 1000 in the one channel that exists to be
|
||||
believed a week later.
|
||||
@@ -534,7 +534,7 @@ about:
|
||||
|---|---|---|
|
||||
| all three reporting 1200 / 2100 / 450 W | `3750.0` | `PV 3 750 W` |
|
||||
| all three reporting, one of them **0 W** | `1650.0` | `PV 1 650 W` |
|
||||
| one of the three `unavailable` | `unknown` | `PV —`, plus a caution naming which entity, why, and what the others reported |
|
||||
| one of the three `unavailable` | `unknown` | `PV —`, plus a caution naming which source is missing |
|
||||
| all three gone | `unknown` | as above |
|
||||
|
||||
**It does not publish the sum of the ones that answered.** Two inverters out of
|
||||
@@ -546,8 +546,8 @@ it say something false. So the total goes to `unknown` and the recorder stores a
|
||||
gap, exactly as it does for a single dead sensor.
|
||||
|
||||
The diagnostic is not thrown away — it is put where a person will see it. The
|
||||
status page names the entity that is missing, the reason, **and** what the
|
||||
others reported. That page is read live by a human who wants to fix something;
|
||||
status page names the missing source by its place in the `pv_entities` list
|
||||
(*source 2 of 3*). That page is read live by a human who wants to fix something;
|
||||
the recorded number is read cold by an analysis that would believe it.
|
||||
|
||||
Note the **third row against the second**: a member honestly reporting `0 W` is
|
||||
@@ -569,7 +569,7 @@ It is **instrumentation**. It is not an input to the control law, the
|
||||
allocator, the arbiter, the peak guard, the maintenance cycle or any watchdog;
|
||||
it is not part of `inputs_ok`, so a PV integration that breaks cannot stop the
|
||||
battery being regulated; and its status row is a **caution**, never a
|
||||
`NOT READY`. Wiring production into the control law would be a behaviour change
|
||||
*Not ready*. Wiring production into the control law would be a behaviour change
|
||||
on a system driving a real battery — and it would destroy the measurement,
|
||||
because the loop would then be reacting to the thing being measured.
|
||||
|
||||
@@ -791,8 +791,8 @@ repeats. Thresholding that at 30 s would rebuild the false-trip limit cycle at
|
||||
the exact operating point the controller aims for. Freeze detection is a
|
||||
separate problem and needs the low-power case solved first.
|
||||
|
||||
You read it yourself instead: the add-on's status page shows it on the P1 line,
|
||||
as `… 4 rejected, measurement unchanged for 312 s`. On a house drawing real
|
||||
You read it yourself instead: the add-on's status page shows it on the Meter
|
||||
row, as `… 4 readings refused, unchanged for 5 minutes`. On a house drawing real
|
||||
power that figure stays in the seconds; minutes of it while the load is clearly
|
||||
not near zero is the meter to go and look at.
|
||||
|
||||
@@ -1050,9 +1050,9 @@ If the setpoint this add-on is emitting and the grid figure it is regulating on
|
||||
point **opposite ways** — charging the battery while the house imports, or
|
||||
discharging it while the house exports — with both over `sign_disagree_w`, for
|
||||
`sign_disagree_s` **continuously**, the add-on commands **0 W** and holds it
|
||||
there. The banner reads `FAILSAFE`, the commissioning list says which two
|
||||
numbers disagreed and for how long, and the `Controller status` entity reports
|
||||
`failsafe`.
|
||||
there. The banner reads *Command and meter point opposite ways*, the add-on
|
||||
log says which two numbers disagreed and for how long, and the `Controller
|
||||
status` entity reports `failsafe`.
|
||||
|
||||
#### ⚠️ At two or more inverters this is TWO checks, not one (SAFETY-30)
|
||||
|
||||
@@ -1194,7 +1194,8 @@ start, because a `persistent_notification` is in memory and that is precisely ho
|
||||
the 2026-09-02 outage went unseen. It is cleared by pressing **Start**, like the
|
||||
other latches.
|
||||
|
||||
The banner reads **`NOT DELIVERING — <unit> …`** as a *warning*, not a failure,
|
||||
The banner reads **`<unit> is not delivering. Control keeps running.`** as a
|
||||
*warning*, not a failure,
|
||||
and it **displaces** `Running — holding grid at zero`. That last sentence is a
|
||||
claim the site cannot make while a unit is absent, and a page that goes on
|
||||
reading healthy while the fault runs is the whole shape this check exists to
|
||||
@@ -1428,7 +1429,7 @@ What exists today, and what does not:
|
||||
| SoC guard on the loop | ❌ — the BMS is the only energy backstop |
|
||||
|
||||
On the legacy `meter_source: off` path there are no P1 telegrams, so there is no
|
||||
quarter-hour average to guard, and the status page says **NOT COVERED**. There
|
||||
quarter-hour average to guard, and the status page says *Peak guard: off*. There
|
||||
the mitigation is still operational: set `max_w` no higher than the loop actually
|
||||
needs (the tuning was measured at 2000 W and a 1.78 kW load step is tracked fine
|
||||
there), fit the e-stop, and watch for the alarm.
|
||||
@@ -1712,13 +1713,13 @@ the add-on UI.
|
||||
|
||||
⚠️ **Only `meter_source: homewizard_local` is covered.** It is the only transport
|
||||
that reads the meter's own document; on `ha_dsmr`, `mqtt_p1`, `ha_signed` and
|
||||
`off` there is no signal to threshold and the status page says **NOT COVERED**
|
||||
rather than pretending the guard is armed.
|
||||
`off` there is no signal to threshold and the status page says *Stuck-meter
|
||||
check: off* rather than pretending the guard is armed.
|
||||
|
||||
The same row appears for a second reason: a setpoint device that reports a range
|
||||
from which no command magnitude is available in both directions leaves no rail
|
||||
to measure at all, and a 0 W rail would be satisfied by *every* command. That is
|
||||
reported as **NOT COVERED** too, and the detector stays silent rather than
|
||||
reported as *off* too, and the detector stays silent rather than
|
||||
degenerating into the bare "unchanged for N seconds" rule this design exists to
|
||||
avoid.
|
||||
|
||||
@@ -2804,123 +2805,170 @@ it.
|
||||
|
||||
## Notifications
|
||||
|
||||
Each Home Assistant notification this add-on raises has a short title, one
|
||||
sentence (a red alarm may use three), and a **Details** link to the add-on
|
||||
documentation that names the section below. This section holds what the
|
||||
notification leaves out. The wording rule is `STYLE.md` in the repository; the
|
||||
texts live in `app/messages.py`. Every notification keeps a fixed
|
||||
`notification_id`, so a repeat replaces the card instead of adding one.
|
||||
The add-on tells you about a problem with a Home Assistant notification. Each
|
||||
one has a short title, one to three sentences, and a **Details** link to this
|
||||
page. The link opens the add-on's Documentation tab. Look for the section with
|
||||
the same name as the notification title below. A repeat of the same problem
|
||||
replaces the notification rather than adding a new one.
|
||||
|
||||
| Title | Severity | id |
|
||||
|---|---|---|
|
||||
| Battery is not keeping up | warning | `goodwe_integrator_bound` |
|
||||
| Power request too high | alarm | `goodwe_output_clamp` |
|
||||
| Load too high for battery | alarm | `goodwe_peak_saturated` |
|
||||
| Battery stopped limiting the peak | alarm | `goodwe_peak_soc_floor` |
|
||||
| Inverters working against each other | alarm | `goodwe_circulating_power` |
|
||||
| *name* is not delivering | alarm | `goodwe_not_delivering_<name>` |
|
||||
| Meter reading may be stuck | alarm | `goodwe_meter_frozen` |
|
||||
In **shadow mode** the add-on makes every decision but sends nothing: every
|
||||
inverter stays at 0 W. Notifications then say what the add-on *would* have
|
||||
sent.
|
||||
|
||||
### Battery is not keeping up
|
||||
|
||||
The grid-following loop's integrator reached its anti-windup bound
|
||||
(`integrator_max_w`): the controller has been asking for more than the battery
|
||||
delivers for a while. This is SAFETY-40, and it is **not** a fault. No command
|
||||
went over the rating and control keeps running. Short spells after a big load
|
||||
or solar step are normal. If it keeps coming back, check that the battery
|
||||
follows its commands. The bound and the command of that tick are in the add-on
|
||||
log (WARNING, reason code `OUTPUT_CLAMP`). See *The winding-loop alarm* for the
|
||||
full story.
|
||||
The battery gives less power than the add-on asks for. This is normal for a
|
||||
short time, for example just after a large load switches on or the sun comes
|
||||
out. It is not a fault, and control keeps running. If it keeps coming back,
|
||||
check that the battery is switched on, and that it is not empty (when it should
|
||||
give power) or full (when it should charge).
|
||||
|
||||
### Power request too high
|
||||
|
||||
The controller computed a command above a limit, and the command was cut to that
|
||||
limit before it was written. The notification names what was asked, what was
|
||||
sent, and which limit cut it: the configured inverter rating (`max_w`), the
|
||||
inverter's own limit (the setpoint device's range), or the inverter rating on
|
||||
the loop side. Asked always comes first. This is a **software fault** (the old
|
||||
wording was "BUG SIGNAL"). It is not the inverter failing to follow a legal
|
||||
command, which is the saturation freeze and does not alarm. Control keeps
|
||||
running. Report it with the add-on log, whose ERROR line carries the reason code
|
||||
`OUTPUT_CLAMP` and the full figures. See *The winding-loop alarm*.
|
||||
The add-on worked out a power request above what is allowed, and cut it back
|
||||
before sending it. The notification shows what was asked and what was sent,
|
||||
and which limit cut it: the “Inverter rating” setting, or the inverter's own
|
||||
limit. In shadow mode it shows what *would* have been sent. Control keeps
|
||||
running. This should never happen, so it is a software fault: please send the
|
||||
notification and the add-on log to your installer.
|
||||
|
||||
### Load too high for battery
|
||||
|
||||
The capacity-peak guard (SAFETY-07) is asking for everything the inverter can
|
||||
discharge, and the running 15-minute average is still projected over the peak
|
||||
limit. That 15-minute period will set or raise the month's billed peak
|
||||
(capaciteitstarief). The controller is not at fault: the house load is larger
|
||||
than the inverter. Switching off load in the next few minutes is the only thing
|
||||
that still changes the bill. The projection and the watts are in the add-on log
|
||||
and on the status page. See *The capacity-peak guard*.
|
||||
Your home uses more power than the battery can supply, so this 15-minute
|
||||
period will go over your peak limit and raise this month's peak. The battery
|
||||
is already giving all it can. This is not a fault. Switch off large loads,
|
||||
such as an oven, a car charger or a heat pump, for the next few minutes. In
|
||||
shadow mode the battery gives nothing, so this can happen with a much smaller
|
||||
load.
|
||||
|
||||
### Battery stopped limiting the peak
|
||||
|
||||
Two words in this notification are settings. The **peak reserve** is
|
||||
*Peak guard will not discharge below (%)* (`peak_soc_floor`). The
|
||||
**cut-out level** is *Battery cut-out level (%)* (`bms_soc_floor`), where the
|
||||
battery's own system stops discharging.
|
||||
The add-on stopped using the battery to keep your peak down, so this
|
||||
15-minute period will go over your peak limit and raise this month's peak.
|
||||
Switch off large loads for the next few minutes. The notification says why,
|
||||
and what to do:
|
||||
|
||||
The peak guard wanted to discharge to hold the 15-minute peak, but it may not go
|
||||
below the peak reserve (`peak_soc_floor`, SAFETY-24). It also stops when the
|
||||
battery level cannot be read, or when an inverter's cut-out level is not set,
|
||||
because the reserve is graded against it. So this 15-minute
|
||||
period will go over the peak limit and set or raise the month's billed peak.
|
||||
Charging from the grid stays blocked meanwhile. On a site with several inverters
|
||||
the notification names the battery at its limit (SAFETY-32): each battery is
|
||||
graded against its own cut-out level (`bms_soc_floor`), and raising the other
|
||||
batteries' settings will not change this one.
|
||||
- **The battery is at its peak reserve.** The “Peak reserve” setting keeps
|
||||
that much charge back from peak limiting. Lower it if you accept a lower
|
||||
battery level.
|
||||
- **The battery level cannot be read.** Check the “Battery level entity”
|
||||
setting and that sensor in Home Assistant.
|
||||
- **A battery cut-out level is not known.** Fill in “Battery cut-out level”
|
||||
for each inverter in the settings.
|
||||
|
||||
⚠️ **The reserve binds the peak guard only (SAFETY-25).** It is not a
|
||||
whole-battery reserve. Ordinary self-consumption has no such floor and goes on
|
||||
discharging below it, down to the battery's own cut-out level. See *What
|
||||
`peak_soc_floor` does not protect*.
|
||||
The peak reserve only applies to keeping the peak down. Normal home use can
|
||||
still draw the battery below it, down to the battery cut-out level, where the
|
||||
battery switches itself off.
|
||||
|
||||
### Inverters working against each other
|
||||
|
||||
Two inverters were pushing power into each other: one discharging while another
|
||||
charged (SAFETY-31). **The meter cannot see this.** The two flows cancel at the
|
||||
P1 meter, so the site reads idle while both batteries cycle through two
|
||||
conversion stages. Every other guard reads that net figure, so none of them
|
||||
fires. The add-on has **stopped control and commands 0 W on every inverter**.
|
||||
If the grid reading does not move after that, one inverter is no longer
|
||||
listening to the add-on; this has happened on this hardware, once for
|
||||
6 h 25 min. Switch the inverters off at the isolator. The alarm is latched: a
|
||||
Home Assistant or add-on restart does not clear it, and the card is raised
|
||||
again every 5 min until you start control on the add-on page. The watts and the time
|
||||
window are in the add-on log and on the status page. See *The circulating-power
|
||||
alarm*.
|
||||
With several inverters, one was charging its battery from another. Your meter
|
||||
cannot see this, because the two flows cancel out, but it wastes energy. The
|
||||
add-on has stopped control and set every inverter to 0 W. If the grid power
|
||||
does not change after that, switch the inverters off at the isolator. A
|
||||
restart does not clear this. Find out why, then start control on the add-on
|
||||
page.
|
||||
|
||||
### An inverter is not delivering
|
||||
|
||||
One inverter has stood well short of its share of the site target for longer
|
||||
than the hold time (SAFETY-42), while the others have not. No other check sees
|
||||
this. A unit at 0 W is absent rather than pushing the wrong way, so the per-unit
|
||||
sign check and the circulation check stay quiet. **Nothing is commanded
|
||||
differently.** The guard only reports: commanding an inverter that has stopped
|
||||
listening achieves nothing, and the only fallback the add-on has is
|
||||
all-or-nothing. The other inverters keep regulating, and the site is short by up
|
||||
to the missing unit's rating. Check, in this order:
|
||||
With several inverters, one gives much less power than it is asked for, while
|
||||
the others do. Nothing is changed: control keeps running, and the other
|
||||
inverters carry on. Check, in this order:
|
||||
|
||||
1. Is the inverter answering on RS485 at all?
|
||||
2. Is its battery colder or emptier than its configured cut-out level
|
||||
(`bms_soc_floor`) says? If so, that setting does not describe this battery.
|
||||
3. Is anything else writing to it?
|
||||
1. Is the inverter on and connected?
|
||||
2. Is its battery empty or cold? If it is emptier than its “Battery cut-out
|
||||
level” says, that setting does not match this battery.
|
||||
3. Is anything else controlling it?
|
||||
|
||||
The alarm is latched and survives restarts. Control is still running, so to
|
||||
clear it, press *Start / stop control* twice (stop, then start) once you know
|
||||
why. See *A unit that stops DELIVERING is a third fault again*.
|
||||
A restart does not clear this. Once you know why, stop and then start control
|
||||
on the add-on page.
|
||||
|
||||
### Meter reading may be stuck
|
||||
|
||||
The meter keeps answering, but its value has not changed for longer than the
|
||||
hold time while the command stands at the power limit (SAFETY-18). The loop is
|
||||
regulating against a number that has stopped moving. The age is still fresh, so
|
||||
no other guard stops it. This is an alarm only: control keeps running and keeps
|
||||
following the reading. Held for a whole 15-minute period, it can set the month's
|
||||
billed peak. Check the meter; if it is stuck, stop control on the add-on page.
|
||||
The limit and command figures are in the add-on log and on the status page. See
|
||||
*The frozen-meter alarm*.
|
||||
The meter keeps answering, but its value has not changed for a long time while
|
||||
the add-on asks the battery for full power. That usually means the meter
|
||||
reading is stuck. Control keeps running and keeps following the reading, so a
|
||||
stuck reading can raise this month's peak. Check the meter. If it is stuck,
|
||||
stop control on the add-on page.
|
||||
|
||||
### For installers: notifications
|
||||
|
||||
This part is for installers. The texts live in `app/messages.py` and follow
|
||||
`STYLE.md`. Every notification keeps a fixed `notification_id`, so a repeat
|
||||
replaces the card. The full figures and reason codes are on the ERROR or
|
||||
WARNING line of the add-on log.
|
||||
|
||||
| Title | Severity | id | Card |
|
||||
|---|---|---|---|
|
||||
| Battery is not keeping up | warning | `goodwe_integrator_bound` | SAFETY-40 |
|
||||
| Power request too high | alarm | `goodwe_output_clamp` | SAFETY-03 |
|
||||
| Load too high for battery | alarm | `goodwe_peak_saturated` | SAFETY-07 |
|
||||
| Battery stopped limiting the peak | alarm | `goodwe_peak_soc_floor` | SAFETY-24/25/32 |
|
||||
| Inverters working against each other | alarm | `goodwe_circulating_power` | SAFETY-31 |
|
||||
| *name* is not delivering | alarm | `goodwe_not_delivering_<name>` | SAFETY-42 |
|
||||
| Meter reading may be stuck | alarm | `goodwe_meter_frozen` | SAFETY-18 |
|
||||
|
||||
**The Details link.** Home Assistant 2026.2 and newer show add-on pages at
|
||||
`/config/app/<slug>/documentation`; 2026.5 removed the old
|
||||
`/hassio/addon/<slug>/documentation`, which 2026.1 and older still use. At
|
||||
start the add-on reads its slug from `GET /addons/self/info` and the Home
|
||||
Assistant version from `GET /info`, and builds the link for that version. If
|
||||
the version cannot be read it uses the new path. If the slug cannot be read it
|
||||
falls back to the container hostname, and outside an add-on the line names the
|
||||
section without a link. The documentation tab adds no heading anchors, so the
|
||||
link cannot jump to the section.
|
||||
|
||||
**Battery is not keeping up.** The grid-following loop's integrator reached its
|
||||
anti-windup bound (`integrator_max_w`, SAFETY-40). No command went over the
|
||||
rating. The log line is a WARNING with reason code `OUTPUT_CLAMP`. See *The
|
||||
winding-loop alarm*.
|
||||
|
||||
**Power request too high.** A computed command above a limit was cut before it
|
||||
was written (SAFETY-03). The limits are `max_w` (label “Inverter rating”), the
|
||||
setpoint device's own range, or the rating on the loop side. Asked always comes
|
||||
first. The old wording was "BUG SIGNAL". It is not the inverter failing to
|
||||
follow a legal command, which is the saturation freeze and does not alarm. In
|
||||
shadow mode the clamp still grades the decision (SAFETY-10), so the alarm can
|
||||
fire while 0 W is on the wire, and the text says "would have sent". ERROR line,
|
||||
reason code `OUTPUT_CLAMP`.
|
||||
|
||||
**Load too high for battery.** The capacity-peak guard (SAFETY-07) asks for
|
||||
everything the inverter can discharge and the running 15-minute average is
|
||||
still projected over the peak limit, so the month's billed peak
|
||||
(capaciteitstarief) goes up. In shadow mode the guard's projection is made on a
|
||||
plant that did not respond (SAFETY-47), and the text says so. See *The
|
||||
capacity-peak guard*.
|
||||
|
||||
**Battery stopped limiting the peak.** The peak guard may not discharge below
|
||||
`peak_soc_floor` (label “Peak reserve”, SAFETY-24). It also stops when the
|
||||
state of charge is unread, or when an inverter's `bms_soc_floor` (label
|
||||
“Battery cut-out level”) is missing, because the reserve is graded against it.
|
||||
Charging from the grid stays blocked meanwhile. With several inverters the
|
||||
notification names the battery at its limit (SAFETY-32), each graded against
|
||||
its own cut-out level. ⚠️ **The reserve binds the peak guard only
|
||||
(SAFETY-25).** Self-consumption has no such floor. See *What `peak_soc_floor`
|
||||
does not protect*.
|
||||
|
||||
**Inverters working against each other.** SAFETY-31. The flows cancel at the
|
||||
P1 meter, so every other guard, which reads that net figure, stays quiet. This
|
||||
has happened on this hardware once for 6 h 25 min. The alarm is latched,
|
||||
survives restarts, and is raised again every 5 min until control is started.
|
||||
The watts and the time window are in the log; the *Circulating power check*
|
||||
row shows the live watts. See *The circulating-power alarm*.
|
||||
|
||||
**An inverter is not delivering.** SAFETY-42. The unit stood well short of its
|
||||
share of the site target for longer than `delivery_hold_s`. A unit at 0 W is
|
||||
absent rather than pushing the wrong way, so the per-unit sign check and the
|
||||
circulation check stay quiet. The guard only reports: commanding an inverter
|
||||
that has stopped listening achieves nothing. Check first whether it answers on
|
||||
RS485. The alarm is latched and survives restarts; stop then start clears it.
|
||||
See *A unit that stops DELIVERING is a third fault again*.
|
||||
|
||||
**Meter reading may be stuck.** SAFETY-18. The value has not changed for
|
||||
longer than `meter_freeze_s` while the command stands at the power limit, and
|
||||
the age is still fresh, so no other guard stops it. Only `meter_source:
|
||||
homewizard_local` can tell a silent meter from an unchanged value. The limit
|
||||
and command figures are in the log. See *The frozen-meter alarm*.
|
||||
|
||||
## The Web UI
|
||||
|
||||
@@ -2935,6 +2983,64 @@ inverter.** The configuration page reads and writes the add-on's own settings
|
||||
and can restart the add-on; the set of commands that reach the hardware is
|
||||
exactly the three buttons it always had.
|
||||
|
||||
## Status page
|
||||
|
||||
The add-on page shows a banner at the top and a **Commissioning** list below
|
||||
it. The banner says in one line what matters most now. Each row of the list is
|
||||
one check: ✓ green is fine, ! amber needs a look, ✗ red needs action. Rows name
|
||||
settings by their label, never by a Home Assistant entity id.
|
||||
|
||||
In **shadow mode** the banner says so first, whatever else is going on: the
|
||||
add-on makes every decision but the battery is not controlled, and every
|
||||
inverter stays at 0 W. If the banner is red and says a safety stop stays on,
|
||||
one of the red rows below is a stop that will still be there when shadow mode
|
||||
ends. That row says how to clear it.
|
||||
|
||||
| Row starts with | What it tells you |
|
||||
|---|---|
|
||||
| Control | When control last ran. Red when it has stopped running: the control board then sets the inverter to 0 W. |
|
||||
| Meter | The grid reading, its age, how many readings were refused, and how long its value has not changed. |
|
||||
| Stuck-meter check | Whether the add-on can warn you about a stuck meter. |
|
||||
| Meter reading may be stuck | See *Meter reading may be stuck* under Notifications. |
|
||||
| *month*: peak … | This month's peak, and how close it is to your peak limit. |
|
||||
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. |
|
||||
| Battery level, Battery power, Grid power | The reading of that entity. *No usable reading* means the entity is missing, or its reading is too old. Check it in Developer Tools before replacing it. |
|
||||
| Inverter control | Whether the inverter can be controlled, and the power range it accepts. |
|
||||
| *name*: … cannot be controlled, commands refused, “Setpoint entity” is not set | Whether each inverter still takes commands. |
|
||||
| Power request too high, Battery is not keeping up | See those titles under Notifications. Each shows how often it happened since the add-on started, and *fine now* once it has cleared. In shadow mode the row says what *would* have been sent. |
|
||||
| Direction check, Site direction check | Whether each inverter's power goes the way it is told. *Opposite for 12 of 60 seconds* counts toward a stop. When it stops, the inverter, or every inverter, is set to 0 W until you start control. |
|
||||
| Circulating power check, Inverters worked against each other | Only with several inverters. See *Inverters working against each other*. |
|
||||
| Delivery check, *name* is not delivering | Only with several inverters. See *An inverter is not delivering*. |
|
||||
| Solar production | Your solar production. Sources are numbered in the order of “Solar production entities, per inverter”. A strongly negative reading by day means that entity reads the wrong way round: add it to “Reversed-sign solar entities”. |
|
||||
|
||||
### For installers: status page
|
||||
|
||||
The texts are in `app/messages.py`. The full figures of any alarm are on its
|
||||
ERROR or WARNING line in the add-on log.
|
||||
|
||||
- **Stuck-meter check: off** needs `meter_source: homewizard_local` (label
|
||||
“Where the meter reading comes from”), a `max_w` (“Inverter rating”) and a
|
||||
power range the inverter can reach. *The inverter's own limit* means the
|
||||
setpoint device's range sets the threshold, below `max_w`.
|
||||
- **Peak guard: off** means `meter_source` is `off`, so there is no 15-minute
|
||||
average to guard.
|
||||
- **Battery level / Battery power / Grid power** are `soc_entity`,
|
||||
`batt_entity` and `meter_entity`. *No usable reading* is SAFETY-56: missing
|
||||
**or** held back as stale, and a separate stale-reading row then says which.
|
||||
- **Inverter control** is the `setpoint_entity` and the range it accepts.
|
||||
- ***name* cannot be controlled** (red): every write was rejected for
|
||||
`LINK_STALE_S`, so the unit is dropped and the others carry its share
|
||||
(DEV-02). ***name*: commands refused** (amber) is the same before that limit.
|
||||
***name*: “Setpoint entity” is not set** (amber): a roster entry nobody can
|
||||
write, so the site refuses to run at part strength and holds 0 W.
|
||||
- **Direction check, Site direction check** are the sign checks (SAFETY-02/30).
|
||||
**Circulating power check** is SAFETY-31, **Delivery check** SAFETY-42.
|
||||
- **Solar production** reads `pv_entity` or `pv_entities` (TEL-11/12). The
|
||||
*Reversed-sign solar entities* setting is `pv_invert_entities` (TEL-14).
|
||||
- **Shadow mode** (SAFETY-10): the banner turns red when a latch is up
|
||||
(circulating power, or a site or per-inverter sign trip), and that latch keeps
|
||||
its own red row.
|
||||
|
||||
## Status entities
|
||||
|
||||
If an MQTT broker is available the add-on publishes setpoint, grid power,
|
||||
|
||||
@@ -358,6 +358,10 @@ class ClampWatchdog:
|
||||
def __init__(self):
|
||||
self.active = False
|
||||
self.engagements = 0 # every engagement, never deduplicated
|
||||
# UX-08: the same count split by alarm type, so the status page names
|
||||
# each with its own alarm's title after the episode clears.
|
||||
self.over_rating = 0 # bug=True: "Power request too high"
|
||||
self.bound = 0 # bug=False: "Battery is not keeping up"
|
||||
self.episodes = 0 # rising edges
|
||||
self.since: datetime | None = None
|
||||
self.last_alarm: datetime | None = None
|
||||
@@ -399,6 +403,10 @@ class ClampWatchdog:
|
||||
"""
|
||||
if engaged:
|
||||
self.engagements += 1
|
||||
if bug:
|
||||
self.over_rating += 1
|
||||
else:
|
||||
self.bound += 1
|
||||
self.clean_cycles = 0
|
||||
self.run_len += 1
|
||||
rising = not self.active
|
||||
|
||||
@@ -123,6 +123,7 @@ from datetime import datetime
|
||||
|
||||
from .clamp import ClampResult
|
||||
from .delivery import DeliveryConfig, DeliveryWatchdog
|
||||
from . import messages
|
||||
# SAFETY-37. The freshness policy, and the ONE place its bounds are written.
|
||||
# freshness.py imports nothing from this package, so the direction is one-way.
|
||||
from .freshness import BOUNDS, Freshness
|
||||
@@ -410,18 +411,20 @@ class Inverter:
|
||||
return self.batt_fresh.note(self.name)
|
||||
|
||||
def link_note(self, now: datetime) -> str:
|
||||
"""One line for the status page. Empty when there is nothing to say."""
|
||||
"""One line for the status page. Empty when there is nothing to say.
|
||||
|
||||
The words are `app/messages.py`'s (UX-09). main.py colours the row red
|
||||
exactly when `is_live()` is False.
|
||||
"""
|
||||
if not self.has_writer():
|
||||
return (f"{self.name}: NO SETPOINT ENTITY - this controller cannot "
|
||||
f"command it, and the site refuses rather than running at "
|
||||
f"part strength")
|
||||
live, why = self.is_live(now)
|
||||
return messages.row_no_setpoint(self.name)
|
||||
live, _why = self.is_live(now)
|
||||
held = (0.0 if self.rejected_since is None
|
||||
else (now - self.rejected_since).total_seconds())
|
||||
if not live:
|
||||
return f"{self.name}: NOT COMMANDABLE - {why}"
|
||||
return messages.row_not_controllable(self.name, held, LINK_STALE_S)
|
||||
if self.rejected_since is not None:
|
||||
held = (now - self.rejected_since).total_seconds()
|
||||
return (f"{self.name}: writes rejected for {held:.0f} s - still "
|
||||
f"commandable until {LINK_STALE_S:.0f} s")
|
||||
return messages.row_commands_refused(self.name, held, LINK_STALE_S)
|
||||
return ""
|
||||
|
||||
def __repr__(self) -> str:
|
||||
|
||||
+241
-310
@@ -3796,7 +3796,8 @@ class Controller:
|
||||
# UX-08: the words are messages.output_clamp()'s; the numbers are the
|
||||
# ones `reason` was written from (ClampWatchdog.facts), asked first.
|
||||
await self.hass.call("persistent_notification", "create",
|
||||
messages.output_clamp(self.clamp_wd.facts).data())
|
||||
messages.output_clamp(self.clamp_wd.facts,
|
||||
shadow=self.shadow).data())
|
||||
|
||||
async def check_peak_saturated(self) -> None:
|
||||
"""SAFETY-07. Alarm ONLY when the guard has run out of inverter.
|
||||
@@ -3839,7 +3840,8 @@ class Controller:
|
||||
# here - check_meter_frozen() gives the reasoning. A saturated peak guard
|
||||
# is not a frozen meter and is not an out-of-range setpoint.
|
||||
await self.hass.call("persistent_notification", "create",
|
||||
messages.peak_saturated(g.ceiling_w).data())
|
||||
messages.peak_saturated(
|
||||
g.ceiling_w, shadow=self.shadow).data())
|
||||
|
||||
async def check_peak_floor_limited(self) -> None:
|
||||
"""SAFETY-24. Alarm when the EMS SoC floor stops the guard shaving.
|
||||
@@ -4551,27 +4553,24 @@ class Controller:
|
||||
# SAFETY-61. First, so a stalled loop is the headline: the heartbeat is
|
||||
# sent from this loop, so past layer 1's veto the inverter is at 0 W.
|
||||
if self.loop_pass_mono is None:
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": "control loop: starting"})
|
||||
out.append({"ok": True, "warn": False, "id": "controller",
|
||||
"text": messages.row_controller_starting()})
|
||||
else:
|
||||
_pass_age = time.monotonic() - self.loop_pass_mono
|
||||
if _pass_age > FIRMWARE_INGEST_VETO_S:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"control loop: NO PASS FOR {_pass_age:.0f} s"
|
||||
f" (layer 1 zeroes the inverter after "
|
||||
f"{FIRMWARE_INGEST_VETO_S:.0f} s without a "
|
||||
f"heartbeat)"})
|
||||
out.append({"ok": False, "warn": False, "id": "controller",
|
||||
"text": messages.row_controller_stalled(
|
||||
_pass_age, FIRMWARE_INGEST_VETO_S)})
|
||||
else:
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"control loop: last pass {_pass_age:.0f} s ago"})
|
||||
out.append({"ok": True, "warn": False, "id": "controller",
|
||||
"text": messages.row_controller_ran(_pass_age)})
|
||||
if self.p1_enabled:
|
||||
age = self.p1.published_age_s
|
||||
if self.p1.stale:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"P1 meter ({o.get('meter_source')}): no reading for "
|
||||
f"{age:.0f} s (limit {self.p1.max_age_s:.0f} s)"
|
||||
+ (f" - last error: {self.p1.last_error}"
|
||||
if self.p1.last_error else "")})
|
||||
# The last error is on the add-on log's WARNING line (p1.py).
|
||||
out.append({"ok": False, "warn": False, "id": "meter",
|
||||
"text": messages.row_meter_stale(
|
||||
age, self.p1.max_age_s)})
|
||||
else:
|
||||
# ⚠️ unchanged_s is REPORTED, never thresholded and never folded
|
||||
# into the age - see HomeWizardLocalSource.unchanged_s for why
|
||||
@@ -4583,33 +4582,26 @@ class Controller:
|
||||
# only homewizard_local has one, and p1_source is None until
|
||||
# amain() builds the transport.
|
||||
unchanged = getattr(self.p1_source, "unchanged_s", None)
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"P1 meter ({o.get('meter_source')}): {self.p1.net_w:g} W, "
|
||||
f"{age:.0f} s old, {self.p1.samples} telegrams, "
|
||||
f"{self.p1.parse_errors} rejected"
|
||||
+ (f", measurement unchanged for {unchanged:.0f} s"
|
||||
if unchanged is not None else "")})
|
||||
out.append({"ok": True, "warn": False, "id": "meter",
|
||||
"text": messages.row_meter(
|
||||
self.p1.net_w, age, self.p1.parse_errors,
|
||||
unchanged)})
|
||||
# SAFETY-18. Reported in both states, for the reason SAFETY-02 is:
|
||||
# a detector nobody can see is armed is a detector nobody trusts
|
||||
# when it fires. ok=False/warn=False so the banner goes red - this
|
||||
# is an alarm, and the banner is the loudest surface we own. It
|
||||
# changes NOTHING about control; see check_meter_frozen().
|
||||
if self.freeze_wd.active:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "METER MAY BE FROZEN - " + self.freeze_wd.reason
|
||||
+ ". The loop is STILL FOLLOWING it and is "
|
||||
"still running. Check the meter. Held here "
|
||||
"for a quarter of an hour this sets the "
|
||||
"month's billed capacity peak."})
|
||||
# The figures are in `freeze_wd.reason`, on the log and the
|
||||
# event list (check_meter_frozen()).
|
||||
out.append({"ok": False, "warn": False, "id": "meter_frozen",
|
||||
"text": messages.row_meter_frozen()})
|
||||
elif getattr(self.p1_source, "unchanged_s", None) is None:
|
||||
# Not "armed". Every transport but homewizard_local is invisible
|
||||
# to this check, and saying "armed" there would be a lie the
|
||||
# status page tells on behalf of a guard that cannot run.
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"freeze detector: NOT COVERED on "
|
||||
f"meter_source {o.get('meter_source')} - only "
|
||||
f"homewizard_local sees whether the meter's own "
|
||||
f"document changes"})
|
||||
out.append({"ok": False, "warn": True, "id": "freeze_check",
|
||||
"text": messages.row_freeze_off("source")})
|
||||
elif rail_unreachable(self.site_max_w,
|
||||
dev_min=self.site_dev_bound("dev_min"),
|
||||
dev_max=self.site_dev_bound("dev_max")):
|
||||
@@ -4619,12 +4611,11 @@ class Controller:
|
||||
# and an operator does not need to learn two vocabularies for
|
||||
# it. What differs is only which term is missing: there,
|
||||
# `unchanged_s`; here, a rail the command could ever stand at.
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"freeze detector: NOT COVERED - "
|
||||
+ rail_unreachable(
|
||||
self.site_max_w,
|
||||
dev_min=self.site_dev_bound("dev_min"),
|
||||
dev_max=self.site_dev_bound("dev_max"))})
|
||||
_no_rating = (not self.site_max_w
|
||||
or not is_commandable(self.site_max_w))
|
||||
out.append({"ok": False, "warn": True, "id": "freeze_check",
|
||||
"text": messages.row_freeze_off(
|
||||
"rating" if _no_rating else "range")})
|
||||
else:
|
||||
# ⚠️ SAFETY-20. THE RAIL PRINTED HERE IS THE RAIL THE PREDICATE
|
||||
# USES, device range included. This row used to interpolate
|
||||
@@ -4643,17 +4634,12 @@ class Controller:
|
||||
# reads `min` and `max` independently and returns None for
|
||||
# whichever attribute is missing or unparseable - so this
|
||||
# renders whatever is there rather than formatting a None.
|
||||
_cap = ("" if _rail >= rail_w(self.site_max_w)
|
||||
else " - below max_w because "
|
||||
+ "; ".join(
|
||||
f"{inv.setpoint_entity or inv.name} accepts "
|
||||
f"only {inv.dev_min}...{inv.dev_max} W"
|
||||
for inv in self.inverters))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"freeze detector: armed (alerts after "
|
||||
f"{self.freeze_wd.cfg.hold_s:.0f} s unchanged "
|
||||
f"while the command is over "
|
||||
f"{_rail:.0f} W{_cap})"})
|
||||
# UX-08: "the inverter's own limit" says the device set it; which
|
||||
# inverter and its range are DOCS and the settings, not entity ids.
|
||||
out.append({"ok": True, "warn": False, "id": "freeze_check",
|
||||
"text": messages.row_freeze_on(
|
||||
self.freeze_wd.cfg.hold_s, _rail,
|
||||
own_limit=_rail < rail_w(self.site_max_w))})
|
||||
|
||||
# TARIFF-01. The month's billed peak, and - the load-bearing half -
|
||||
# a DIFFERENT row when the store could not answer. "no peak yet" is
|
||||
@@ -4673,8 +4659,8 @@ class Controller:
|
||||
"text": _pk.explain()
|
||||
+ f" - {_frac * 100:.0f} % of the "
|
||||
f"{self.peak.cap_w:.0f} W soft limit"
|
||||
+ f"; {self.peak.recorded} quarter(s) banked"
|
||||
+ f"; on start: {self.peak.restore_state}"})
|
||||
+ f", {self.peak.recorded} quarter(s) banked"
|
||||
+ f", on start: {self.peak.restore_state}"})
|
||||
|
||||
# SAFETY-07. Three rows, not one, because "idle" and "cannot see"
|
||||
# are opposite states and a page that spelled them the same way
|
||||
@@ -4684,12 +4670,11 @@ class Controller:
|
||||
# decision that has not been taken.
|
||||
_pg = self.peak_guard
|
||||
if _pg is None:
|
||||
out.append({"ok": True, "warn": True,
|
||||
"text": "peak guard: no decision yet - the first "
|
||||
"control cycle has not run"})
|
||||
out.append({"ok": True, "warn": True, "id": "peak_guard",
|
||||
"text": messages.row_peak_guard_waiting()})
|
||||
elif _pg.saturated:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "PEAK GUARD SATURATED - " + _pg.reason})
|
||||
out.append({"ok": False, "warn": False, "id": "peak_guard",
|
||||
"text": messages.row_peak_saturated(_pg.ceiling_w)})
|
||||
elif _pg.floor_limited:
|
||||
# SAFETY-24. NOT ok, like saturation: in both states the money
|
||||
# is going to be spent and a human is the only actuator left. A
|
||||
@@ -4713,22 +4698,27 @@ class Controller:
|
||||
# the whole sentence, because the row is where an operator
|
||||
# reads what the floor does and does not bound. Shortening the
|
||||
# ROW instead would be weakening AC 3.
|
||||
out.append({"ok": False, "warn": False,
|
||||
"banner": _pg.explain()
|
||||
+ " - and peak_soc_floor bounds THE PEAK "
|
||||
"GUARD ONLY (SAFETY-25, see below)",
|
||||
"text": _pg.explain()
|
||||
+ ". NOTE: peak_soc_floor bounds THE PEAK "
|
||||
"GUARD ONLY - it is not a pack-wide "
|
||||
"reserve, and ordinary self-consumption "
|
||||
"has no SoC floor, so the battery may "
|
||||
"keep discharging below this level down "
|
||||
"to the BMS cut-out (SAFETY-25)"})
|
||||
# UX-08: the same three branches, and the same pack naming, as
|
||||
# check_peak_floor_limited()'s notification. The figures stay in
|
||||
# `_pg.reason`, on the log and the event list.
|
||||
_blocked = [name for name, why
|
||||
in peakguard.pack_permissions(self.packs,
|
||||
_pg.soc_floor)
|
||||
if why is not None]
|
||||
out.append({"ok": False, "warn": False, "id": "peak_guard",
|
||||
"banner": messages.banner_peak_reserve(),
|
||||
"text": messages.row_peak_reserve(
|
||||
_pg.ceiling_w, soc_unread=_pg.soc is None,
|
||||
floor_unknown=(_pg.soc is not None
|
||||
and _pg.soc_floor is None),
|
||||
packs=(_blocked if len(self.inverters) > 1
|
||||
else ()))})
|
||||
elif _pg.blind:
|
||||
out.append({"ok": False, "warn": True, "text": _pg.explain()})
|
||||
out.append({"ok": False, "warn": True, "id": "peak_guard",
|
||||
"text": _pg.explain()})
|
||||
else:
|
||||
out.append({"ok": not _pg.engaged, "warn": _pg.engaged,
|
||||
"text": _pg.explain()})
|
||||
"id": "peak_guard", "text": _pg.explain()})
|
||||
else:
|
||||
# ⚠️ OUTSIDE the `p1_enabled` block, and that placement is the point.
|
||||
# SAFETY-07 is NOT COVERED on the legacy single-entity path - the
|
||||
@@ -4737,11 +4727,8 @@ class Controller:
|
||||
# leave the one install that is unprotected showing nothing at all.
|
||||
# Same answer, same reason, as the freeze detector's NOT COVERED row
|
||||
# a few lines up.
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"peak guard: NOT COVERED on meter_source "
|
||||
f"{o.get('meter_source')} - the quarter-hour "
|
||||
f"average is measured from P1 telegrams and this "
|
||||
f"path has none, so a runaway cannot be capped"})
|
||||
out.append({"ok": False, "warn": True, "id": "peak_guard",
|
||||
"text": messages.row_peak_guard_off()})
|
||||
|
||||
# ⚠️ ONE PAIR OF ROWS PER INVERTER, NAMED. A single "battery SoC" row on
|
||||
# a site with two packs is a page that shows one pack and calls it the
|
||||
@@ -4749,17 +4736,21 @@ class Controller:
|
||||
# that is what an existing install reads.
|
||||
rows = []
|
||||
for inv in self.inverters:
|
||||
tag = "" if len(self.inverters) == 1 else f" ({inv.name})"
|
||||
rows.append((f"battery SoC{tag}", inv.soc, inv.soc_entity))
|
||||
rows.append((f"battery power{tag}", inv.batt, inv.batt_entity))
|
||||
unit = None if len(self.inverters) == 1 else inv.name
|
||||
rows.append((messages.LABEL_SOC, unit, inv.soc, inv.soc_entity))
|
||||
rows.append((messages.LABEL_BATTERY, unit, inv.batt,
|
||||
inv.batt_entity))
|
||||
if not self.p1_enabled:
|
||||
# In P1 mode the check above replaces this one; leaving both in
|
||||
# would report "no entity configured" for a meter_entity that is
|
||||
# correctly unused, i.e. a permanent false NOT READY.
|
||||
rows.insert(0, ("grid power", self.grid, o.get("meter_entity")))
|
||||
for label, value, entity in rows:
|
||||
rows.insert(0, (messages.LABEL_GRID, None, self.grid,
|
||||
o.get("meter_entity")))
|
||||
# UX-08: the rows name the setting, never the entity id (STYLE.md).
|
||||
for label, unit, value, entity in rows:
|
||||
if not entity:
|
||||
out.append({"ok": False, "warn": False, "text": f"{label}: no entity configured"})
|
||||
out.append({"ok": False, "warn": False, "id": "sensor",
|
||||
"text": messages.row_sensor_unset(label, unit)})
|
||||
elif value is None:
|
||||
# ⚠️ SAFETY-56. THIS ROW ASSERTED A FALSE FACT ABOUT A NAMED
|
||||
# ENTITY, WHICH IS THE WORST THING A DIAGNOSTIC CAN DO. It read
|
||||
@@ -4783,41 +4774,39 @@ class Controller:
|
||||
# pre-empting the answer. Same reason the wording is not shared
|
||||
# with `freshness._grade()`: that one is a log line about a
|
||||
# BEHAVIOUR, this one is a banner about an ENTITY.
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"{label}: no usable value this cycle from "
|
||||
f"{entity} - and this row cannot tell which "
|
||||
f"of two things that is: the entity is "
|
||||
f"missing or not numeric, or it is "
|
||||
f"publishing a number that this controller "
|
||||
f"is withholding (a freshness gate does "
|
||||
f"exactly that, and names itself in a row "
|
||||
f"of its own). Confirm the entity in "
|
||||
f"Developer Tools before replacing it"})
|
||||
out.append({"ok": False, "warn": False, "id": "sensor",
|
||||
"text": messages.row_sensor_unusable(label, unit)})
|
||||
else:
|
||||
out.append({"ok": True, "warn": False, "text": f"{label}: {entity} = {value:g}"})
|
||||
out.append({"ok": True, "warn": False, "id": "sensor",
|
||||
"text": messages.row_sensor(label, value, unit)})
|
||||
|
||||
for inv in self.inverters:
|
||||
sp = inv.setpoint_entity
|
||||
tag = "" if len(self.inverters) == 1 else f" [{inv.name}]"
|
||||
unit = None if len(self.inverters) == 1 else inv.name
|
||||
if not sp:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"setpoint entity not configured{tag}"})
|
||||
out.append({"ok": False, "warn": False, "id": "control",
|
||||
"text": messages.row_control_unset(unit)})
|
||||
elif inv.dev_max is None:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"setpoint entity {sp} not found"})
|
||||
out.append({"ok": False, "warn": False, "id": "control",
|
||||
"text": messages.row_control_missing(unit)})
|
||||
else:
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"setpoint {sp} (range {inv.dev_min:g}…"
|
||||
f"{inv.dev_max:g} W)"})
|
||||
out.append({"ok": True, "warn": False, "id": "control",
|
||||
"text": messages.row_control(inv.dev_min,
|
||||
inv.dev_max, unit)})
|
||||
|
||||
# DEV-02. Whether this controller can still put a number on each
|
||||
# inverter, and it is reported in the ONE state that matters: a unit
|
||||
# `live_units()` has stopped listing has had its share handed to its
|
||||
# siblings, or - at a roster of one - has taken the site to 0 W. A
|
||||
# dropped link that shows nothing on the page reads as a healthy site.
|
||||
for note in self.liveness_notes():
|
||||
out.append({"ok": False, "warn": "NOT COMMANDABLE" not in note,
|
||||
"text": note})
|
||||
# Red only for a unit that is no longer live; the rest are amber.
|
||||
# The same notes, in the same order, as `liveness_notes()`.
|
||||
_now = datetime.now(timezone.utc)
|
||||
for inv in self.inverters:
|
||||
for note, red in ((inv.link_note(_now), not inv.is_live(_now)[0]),
|
||||
(inv.stale_note(), False)):
|
||||
if note:
|
||||
out.append({"ok": False, "warn": not red, "text": note})
|
||||
|
||||
# SAFETY-03. Red while an over-rating clamp is engaged (amber for the
|
||||
# integrator bound, SAFETY-40), and the engagement COUNT is shown even
|
||||
@@ -4825,28 +4814,41 @@ class Controller:
|
||||
# evidence with it. Reported only when there is something to report:
|
||||
# unlike the freeze detector this guard has no "not covered" state, it
|
||||
# runs on every write on every transport.
|
||||
if self.clamp_wd.active and self.clamp_wd.bug:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "OUTPUT CLAMP ENGAGED - " + self.clamp_wd.reason
|
||||
+ f" Engagements: {self.clamp_wd.engagements}."})
|
||||
elif self.clamp_wd.active:
|
||||
# UX-07 item 1 / UX-08: each count is shown under ITS alarm's name -
|
||||
# over-rating cuts as "Power request too high", integrator-bound cycles
|
||||
# as "Battery is not keeping up" - never the two summed under one.
|
||||
_cw = self.clamp_wd
|
||||
if _cw.active and _cw.bug:
|
||||
out.append({"ok": False, "warn": False, "id": "power_too_high",
|
||||
"banner": messages.banner_power_too_high(),
|
||||
"text": messages.row_power_too_high(
|
||||
_cw.facts, _cw.over_rating, shadow=self.shadow)})
|
||||
elif _cw.active:
|
||||
# SAFETY-40: the integrator bound alone is amber, not red.
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": "LOOP AT INTEGRATOR BOUND - " + self.clamp_wd.reason
|
||||
+ f" Engagements: {self.clamp_wd.engagements}."})
|
||||
elif self.clamp_wd.engagements:
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"output clamp: not engaged now, but it has "
|
||||
f"engaged {self.clamp_wd.engagements} time(s) in "
|
||||
f"{self.clamp_wd.episodes} episode(s) since "
|
||||
f"start - see the event log"})
|
||||
out.append({"ok": False, "warn": True, "id": "not_keeping_up",
|
||||
"text": messages.row_not_keeping_up(_cw.bound)})
|
||||
# No over-rating in THIS episode (`bug` would be set), so any count
|
||||
# is from an earlier one: keep that software-fault evidence shown.
|
||||
if _cw.over_rating:
|
||||
out.append({"ok": False, "warn": True, "id": "power_too_high",
|
||||
"text": messages.row_before(
|
||||
messages.T_OUTPUT_CLAMP, _cw.over_rating)})
|
||||
else:
|
||||
if _cw.over_rating:
|
||||
out.append({"ok": False, "warn": True, "id": "power_too_high",
|
||||
"text": messages.row_before(
|
||||
messages.T_OUTPUT_CLAMP, _cw.over_rating)})
|
||||
if _cw.bound:
|
||||
out.append({"ok": False, "warn": True, "id": "not_keeping_up",
|
||||
"text": messages.row_before(
|
||||
messages.T_LOOP_BOUND, _cw.bound)})
|
||||
|
||||
for inv in self.inverters:
|
||||
if inv.last_write_ok is False:
|
||||
tag = "" if len(self.inverters) == 1 else f" ({inv.name})"
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"last write to the inverter{tag} was "
|
||||
f"REJECTED - check the log"})
|
||||
out.append({"ok": False, "warn": False, "id": "write",
|
||||
"text": messages.row_write_refused(
|
||||
None if len(self.inverters) == 1
|
||||
else inv.name)})
|
||||
|
||||
# SAFETY-02. Reported in both states: a watchdog nobody can see is armed
|
||||
# is a watchdog nobody trusts when it fires.
|
||||
@@ -4861,7 +4863,7 @@ class Controller:
|
||||
# inverter's own power sensor. `sign_wd.against` is the same string the
|
||||
# trip sentence uses, so the two cannot drift apart.
|
||||
for inv in self.inverters:
|
||||
tag = "" if len(self.inverters) == 1 else f" [{inv.name}]"
|
||||
unit = None if len(self.inverters) == 1 else inv.name
|
||||
# ⚠️ ADDED ONLY WHEN THERE IS SOMETHING TO DISAMBIGUATE. At the
|
||||
# shipped roster of one the two sentences below are the ones that
|
||||
# have always been on the page, word for word - AC 8 is about what
|
||||
@@ -4870,25 +4872,16 @@ class Controller:
|
||||
# somebody has learned to recognise. At N>=2 the noun is load-
|
||||
# bearing: the row would otherwise send them to look at P1 for a
|
||||
# fault that is visible only on one inverter's own power sensor.
|
||||
vs = ("" if len(self.inverters) == 1
|
||||
else f" against {inv.sign_wd.against}")
|
||||
# UX-08: at N>=2 `unit` is set, and the row says "its own power".
|
||||
# The figures stay in `sign_wd.reason`, on the log and event list.
|
||||
if inv.sign_wd.tripped:
|
||||
what = ("the meter" if len(self.inverters) == 1
|
||||
else inv.sign_wd.against)
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": f"SIGN-DISAGREEMENT FAILSAFE{tag} - "
|
||||
+ inv.sign_wd.reason
|
||||
+ f". The inverter is held at 0 W. Find out why the "
|
||||
f"command opposed {what} before starting control "
|
||||
"again; starting clears this. Restarting the "
|
||||
"add-on does NOT clear it."})
|
||||
out.append({"ok": False, "warn": False, "id": "direction",
|
||||
"text": messages.row_direction_trip(unit)})
|
||||
else:
|
||||
held = inv.sign_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"sign watchdog{tag}: armed{vs} (trips after "
|
||||
f"{inv.sign_wd.cfg.hold_s:.0f} s opposed, both over "
|
||||
f"{inv.sign_wd.cfg.min_w:.0f} W)"
|
||||
+ (f" - opposed for {held:.0f} s now" if held else "")})
|
||||
out.append({"ok": True, "warn": False, "id": "direction",
|
||||
"text": messages.row_direction_check(
|
||||
held, inv.sign_wd.cfg.hold_s, unit)})
|
||||
|
||||
# --- SAFETY-30: the SITE row -----------------------------------------
|
||||
# ⚠️ ONLY AT N>=2, and the absence at N=1 is the honest report rather
|
||||
@@ -4898,25 +4891,13 @@ class Controller:
|
||||
# operator learns to skim the list.
|
||||
if len(self.inverters) > 1:
|
||||
if self.site_sign_wd.tripped:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "SITE SIGN-DISAGREEMENT FAILSAFE - "
|
||||
+ self.site_sign_wd.reason
|
||||
+ ". EVERY inverter is held at 0 W. This is the "
|
||||
"SUM of the commands against the meter, so it is "
|
||||
"not one inverter's fault to find - look at the "
|
||||
"loop, the integrator and whatever won the "
|
||||
"arbitration. Starting control clears this; "
|
||||
"restarting the add-on does NOT."})
|
||||
out.append({"ok": False, "warn": False, "id": "site_direction",
|
||||
"text": messages.row_site_direction_trip()})
|
||||
else:
|
||||
_sheld = self.site_sign_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"site sign watchdog: armed against the sum of "
|
||||
f"the commands (trips after "
|
||||
f"{self.site_sign_wd.cfg.hold_s:.0f} s opposed, "
|
||||
f"both over "
|
||||
f"{self.site_sign_wd.cfg.min_w:.0f} W)"
|
||||
+ (f" - opposed for {_sheld:.0f} s now"
|
||||
if _sheld else "")})
|
||||
out.append({"ok": True, "warn": False, "id": "site_direction",
|
||||
"text": messages.row_site_direction_check(
|
||||
_sheld, self.site_sign_wd.cfg.hold_s)})
|
||||
|
||||
# --- SAFETY-31 -----------------------------------------------------
|
||||
# ⚠️ SITE-LEVEL, WHERE THE ROWS ABOVE ARE PER-INVERTER, and the row says
|
||||
@@ -4924,28 +4905,20 @@ class Controller:
|
||||
# here would invite the operator to clear "the other one".
|
||||
_circ = self.site_circulating_w
|
||||
if self.circ_wd.tripped:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "CIRCULATING POWER - " + self.circ_wd.reason
|
||||
+ ". EVERY inverter is held at 0 W. The meter "
|
||||
"cannot see this fault, which is why nothing "
|
||||
"else reported it. Starting control clears "
|
||||
"this; restarting the add-on does NOT, and "
|
||||
"neither does restarting Home Assistant."})
|
||||
out.append({"ok": False, "warn": False, "id": "circulating",
|
||||
"text": messages.row_circulating_trip()})
|
||||
elif len(self.inverters) <= 1:
|
||||
# AC 5. At the shipped roster the quantity is identically zero for
|
||||
# every value of every reading, so "armed" would be a claim to be
|
||||
# watching something that cannot happen. Say what is true instead.
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": "circulating power: n/a at one inverter - "
|
||||
"sum(|Bi|) - |sum(Bi)| is identically zero"})
|
||||
out.append({"ok": True, "warn": False, "id": "circulating",
|
||||
"text": messages.row_one_inverter(
|
||||
"Circulating power check")})
|
||||
else:
|
||||
held = self.circ_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": "circulation watchdog: armed (trips after "
|
||||
f"{self.circ_wd.cfg.hold_s:.0f} s over "
|
||||
f"{self.circ_wd.cfg.min_w:.0f} W)"
|
||||
+ (f" - now {_circ:.0f} W" if _circ else "")
|
||||
+ (f", opposed for {held:.0f} s" if held else "")})
|
||||
out.append({"ok": True, "warn": False, "id": "circulating",
|
||||
"text": messages.row_circulating_check(
|
||||
_circ, held, self.circ_wd.cfg.hold_s)})
|
||||
|
||||
# --- SAFETY-42 -------------------------------------------------------
|
||||
# ⚠️ PER INVERTER, AND WARN RATHER THAN BAD, WHICH IS THE ONE PLACE THE
|
||||
@@ -4958,50 +4931,35 @@ class Controller:
|
||||
# caution is what a fault nobody is acting on actually is.
|
||||
if len(self.inverters) > 1:
|
||||
for inv in self.inverters:
|
||||
tag = f" ({inv.name})"
|
||||
if inv.delivery_wd.tripped:
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"NOT DELIVERING{tag} - "
|
||||
+ inv.delivery_wd.reason
|
||||
+ ". Nothing has been commanded differently and "
|
||||
"the rest of the roster is still regulating, "
|
||||
"so the site is short by this unit's share. "
|
||||
"Starting control clears this row; restarting "
|
||||
"the add-on does NOT, and neither does "
|
||||
"restarting Home Assistant."})
|
||||
out.append({"ok": False, "warn": True, "id": "delivery",
|
||||
"text": messages.row_not_delivering(inv.name)})
|
||||
else:
|
||||
_dheld = inv.delivery_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"delivery watchdog{tag}: armed (reports after "
|
||||
f"{inv.delivery_wd.cfg.hold_s:.0f} s short of "
|
||||
f"its share by over "
|
||||
f"{self.tuning.saturation_w:.0f} W, with a "
|
||||
f"sibling that is not)"
|
||||
+ (f" - short for {_dheld:.0f} s now"
|
||||
if _dheld else "")})
|
||||
out.append({"ok": True, "warn": False, "id": "delivery",
|
||||
"text": messages.row_delivery_check(
|
||||
inv.name, _dheld,
|
||||
inv.delivery_wd.cfg.hold_s)})
|
||||
else:
|
||||
# AC 5, and the same honesty `circulating power: n/a` uses one block
|
||||
# up. At one inverter the reduction this check is has no proper
|
||||
# subset to find, for EVERY input, so "armed" would be a claim to be
|
||||
# watching something that cannot happen.
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": "delivery watchdog: n/a at one inverter - a unit "
|
||||
"short of its share is indistinguishable from a "
|
||||
"plant that cannot deliver until there is a "
|
||||
"sibling to compare it with"})
|
||||
out.append({"ok": True, "warn": False, "id": "delivery",
|
||||
"text": messages.row_one_inverter("Delivery check")})
|
||||
|
||||
if not o.get("estop_fitted", False):
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": "no e-stop fitted: if this host dies the battery stays "
|
||||
"latched at its last command"})
|
||||
out.append({"ok": False, "warn": True, "id": "estop",
|
||||
"text": messages.row_no_estop()})
|
||||
else:
|
||||
out.append({"ok": True, "warn": False, "text": "e-stop fitted"})
|
||||
out.append({"ok": True, "warn": False, "id": "estop",
|
||||
"text": messages.row_estop_fitted()})
|
||||
|
||||
if not o.get("peak_forecast_entity"):
|
||||
# ok=False + warn=True renders as a caution, not a pass. A check that
|
||||
# is both is a check nobody reads.
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": "no peak forecast: maintenance charging is not capacity-capped"})
|
||||
out.append({"ok": False, "warn": True, "id": "peak_forecast",
|
||||
"text": messages.row_no_peak_forecast()})
|
||||
# --- TEL-11 ----------------------------------------------------------
|
||||
# ⚠️ NO ROW AT ALL WHEN THE ROSTER IS EMPTY, AND THAT IS A DELIBERATE
|
||||
# DIFFERENCE FROM THE PEAK-FORECAST CAUTION DIRECTLY ABOVE. That one
|
||||
@@ -5017,105 +4975,54 @@ class Controller:
|
||||
# control path. The reason comes from `pv.watts()` rather than being
|
||||
# re-derived here, so the page cannot disagree with the reading.
|
||||
#
|
||||
# --- TEL-12: AND AT A ROSTER OF ONE THESE TWO SENTENCES ARE 0.11.0's --
|
||||
# ⚠️ THE `len(...) == 1` BRANCH IS 0.11.0's CODE UNCHANGED, DOWN TO THE
|
||||
# f-string, so an install that set `pv_entity` reads the row it already
|
||||
# reads. That is an ACCEPTANCE CRITERION rather than a courtesy, and it
|
||||
# is graded across trees by `tools/tel11_pv_trace.py` rather than argued
|
||||
# here: `pv.total()` passes a single entity's `why` through verbatim for
|
||||
# exactly this reason. Multi-entity sentences are separate BECAUSE they
|
||||
# have to say something the single-entity ones never could.
|
||||
# TEL-12 kept 0.11.0's single-entity sentences word for word. UX-08
|
||||
# replaced them on purpose (DECISIONS/UX-08-short-notifications.md), so
|
||||
# a `tools/tel11_pv_trace.py` compare against a pre-UX-08 tree shows
|
||||
# these rows as changed telemetry; the control documents stay equal.
|
||||
roster = self.pv_roster
|
||||
if roster:
|
||||
# TEL-14: each flipped entity is marked where its watts are printed;
|
||||
# an unflipped one gets "", so 0.12.0's sentences are unchanged.
|
||||
# UX-08: sources are numbered in the order of the settings list,
|
||||
# never named by entity id (STYLE.md). The per-source figures and
|
||||
# units are what `pv.total()` returns; they stay in `pv_parts`.
|
||||
flip = pv_read.inverted(self.o)
|
||||
|
||||
def inv(ent):
|
||||
return " [sign inverted]" if ent in flip else ""
|
||||
|
||||
if len(roster) == 1:
|
||||
if self.pv_w is None:
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"PV production: no reading from "
|
||||
f"{roster[0]} - {self.pv_why}"})
|
||||
else:
|
||||
# habit 14: the value sits inside its own literal text, in
|
||||
# its own slot, beside the entity it was read from and the
|
||||
# unit it was read in - so a transposition of any two of the
|
||||
# three is visible in the sentence rather than merely
|
||||
# present in it.
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"PV production: {self.pv_w:.0f} W "
|
||||
f"from {roster[0]} (reported "
|
||||
f"in {self.pv_why})" + inv(roster[0])})
|
||||
n_src = len(roster)
|
||||
if self.pv_w is None and n_src == 1:
|
||||
out.append({"ok": False, "warn": True, "id": "pv",
|
||||
"text": messages.row_pv_none(self.pv_why)})
|
||||
elif self.pv_w is None:
|
||||
# ⚠️ THE ROW THAT SAYS THERE IS NO TOTAL, AND IT SAYS IT IN
|
||||
# THOSE WORDS. `pv.total()`'s note is the argument; this is
|
||||
# where the operator meets it. The partial information is NOT
|
||||
# thrown away - every entity that reported is named with its
|
||||
# watts and every one that did not is named with its reason -
|
||||
# because this surface is read LIVE by a human who wants the
|
||||
# diagnostic, whereas the MQTT row is read back COLD a week
|
||||
# later by an attribution that would believe a smaller number.
|
||||
# Different reader, different instant, different rule.
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": "PV production: NO SITE TOTAL - "
|
||||
+ self.pv_why + ". Reporting: "
|
||||
+ (", ".join(
|
||||
f"{ent} {watt:.0f} W" + inv(ent)
|
||||
for ent, watt, _y in self.pv_parts
|
||||
if watt is not None) or "nothing")})
|
||||
# THOSE WORDS - and which sources are missing, by position.
|
||||
out.append({"ok": False, "warn": True, "id": "pv",
|
||||
"text": messages.row_pv_partial(
|
||||
[i + 1 for i, (_e, watt, _y)
|
||||
in enumerate(self.pv_parts) if watt is None],
|
||||
n_src)})
|
||||
else:
|
||||
# habit 14 at a roster: the total in its own slot, then EVERY
|
||||
# contributor in its own slot with its own watts and its own
|
||||
# unit. A sum that disagrees with the addends it is printed
|
||||
# beside is visible in the sentence.
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"PV production: {self.pv_w:.0f} W from "
|
||||
f"{len(self.pv_parts)} entities ("
|
||||
+ ", ".join(
|
||||
f"{ent} {watt:.0f} W in {why}"
|
||||
+ inv(ent)
|
||||
for ent, watt, why in self.pv_parts)
|
||||
+ ")"})
|
||||
out.append({"ok": True, "warn": False, "id": "pv",
|
||||
"text": messages.row_pv(
|
||||
self.pv_w, n_src,
|
||||
n_src == 1 and roster[0] in flip)})
|
||||
# ⚠️ AND WHEN BOTH KEYS ARE SET, WHICH ONE WON IS STATED. `pv.py`'s
|
||||
# `entities()` makes `pv_entities` REPLACE `pv_entity`, which is the
|
||||
# right rule (its docstring says why) and is also the rule an
|
||||
# operator upgrading from 0.11.0 is most likely to trip over: they
|
||||
# add all their inverters to the new field and the old key is left
|
||||
# standing, doing nothing. A replacement nobody is told about is the
|
||||
# "one of which silently wins" `config.yaml` refuses elsewhere - and
|
||||
# refusing to START over a telemetry key would be observability with
|
||||
# a foot in the control path, so this is a CAUTION and never a `bad`
|
||||
# row.
|
||||
# rule an operator upgrading from 0.11.0 is most likely to trip
|
||||
# over. A CAUTION and never a `bad` row: telemetry must not stop
|
||||
# control.
|
||||
if pv_read.entity_is_ignored(self.o):
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": "PV production: `pv_entities` is set, so "
|
||||
"`pv_entity` is IGNORED - the "
|
||||
f"{len(roster)} entities in the "
|
||||
"list are what is summed. Clear "
|
||||
"`pv_entity` to remove this caution"})
|
||||
out.append({"ok": False, "warn": True, "id": "pv",
|
||||
"text": messages.row_pv_single_ignored()})
|
||||
# TEL-14: a sign that looks reversed, per entity rather than on the
|
||||
# total - see `pv.NEGATIVE_W` and DECISIONS/TEL-14-pv-sign.md §3.
|
||||
for ent, watt, _y in self.pv_parts:
|
||||
for i, (ent, watt, _y) in enumerate(self.pv_parts):
|
||||
if watt is not None and watt < pv_read.NEGATIVE_W:
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"PV production: {ent} reads "
|
||||
f"{watt:.0f} W - far below zero, so "
|
||||
f"its sign is probably reversed. If "
|
||||
f"it is producing now, "
|
||||
+ ("REMOVE it from "
|
||||
"`pv_invert_entities`"
|
||||
if ent in flip else
|
||||
"ADD it to `pv_invert_entities`")
|
||||
+ " in the Configuration tab"})
|
||||
out.append({"ok": False, "warn": True, "id": "pv",
|
||||
"text": messages.row_pv_negative(
|
||||
i + 1, n_src, watt, ent in flip)})
|
||||
_inv_list = [str(x or "").strip()
|
||||
for x in (self.o.get("pv_invert_entities") or [])]
|
||||
for ent in pv_read.stray_inverts(self.o):
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"PV production: `pv_invert_entities` "
|
||||
f"names {ent}, which is not a PV entity in "
|
||||
f"use, so it flips nothing - check the "
|
||||
f"spelling against `pv_entities`"})
|
||||
out.append({"ok": False, "warn": True, "id": "pv",
|
||||
"text": messages.row_pv_stray(
|
||||
_inv_list.index(ent) + 1)})
|
||||
return out
|
||||
|
||||
def status_payload(self) -> dict:
|
||||
@@ -5145,9 +5052,7 @@ class Controller:
|
||||
# is the fault the operator has NO OTHER WAY of learning about: a
|
||||
# sign disagreement is visible at the meter and on every dashboard
|
||||
# in the house, and circulating power is visible nowhere at all.
|
||||
level, banner = "bad", ("CIRCULATING POWER — the inverters were "
|
||||
"pushing against each other. Site held at "
|
||||
"0 W.")
|
||||
level, banner = "bad", messages.banner_circulating()
|
||||
elif self.site_sign_wd.tripped and len(self.inverters) > 1:
|
||||
# SAFETY-30's site half, ABOVE the per-unit rows below and below
|
||||
# circulating power above, and the ordering is the same argument
|
||||
@@ -5156,28 +5061,23 @@ class Controller:
|
||||
# inverter is parked and the fault is in what the site was asking
|
||||
# for, not in one device - naming a unit here would send an operator
|
||||
# to swap the wrong box.
|
||||
level, banner = "bad", ("FAILSAFE — the site's total command "
|
||||
"opposed the meter. Every inverter held at "
|
||||
"0 W.")
|
||||
level, banner = "bad", messages.banner_site_direction()
|
||||
elif any(i.sign_wd.tripped for i in self.inverters):
|
||||
# Outranks "NOT READY": nothing is missing, something went wrong.
|
||||
# ⚠️ THE SENTENCE IS UNCHANGED AT A ROSTER OF ONE, where "the meter"
|
||||
# is what the unit was graded against. At N>=2 it is that unit's own
|
||||
# power, so the banner says so - see checks() on why the noun is
|
||||
# load-bearing rather than cosmetic.
|
||||
level, banner = "bad", (
|
||||
"FAILSAFE — the command opposed the meter. "
|
||||
"Inverter held at 0 W." if len(self.inverters) == 1 else
|
||||
"FAILSAFE — an inverter's command opposed its own measured "
|
||||
"power. That inverter held at 0 W.")
|
||||
# Outranks "Not ready": nothing is missing, something went wrong.
|
||||
# At a roster of one the unit was graded against the meter; at N>=2
|
||||
# against its own power, so the banner says so - see checks() on
|
||||
# why the noun is load-bearing rather than cosmetic.
|
||||
level, banner = "bad", messages.banner_direction(
|
||||
len(self.inverters) > 1)
|
||||
elif bad:
|
||||
# ⚠️ `banner` IF THE ROW OFFERS ONE, `text` OTHERWISE. A row may
|
||||
# need to say more to an operator reading the checks list than fits
|
||||
# in the one line at the top of the page - SAFETY-25's floor-limited
|
||||
# row is the case that forced this - and a headline that is a full
|
||||
# paragraph, repeated verbatim by the row underneath it, is a
|
||||
# headline nobody reads. Rows without the key are unaffected.
|
||||
level, banner = "bad", f"NOT READY — {bad[0].get('banner') or bad[0]['text']}"
|
||||
# headline nobody reads. UX-08: without the key, the banner takes
|
||||
# the row's first sentence, so it stays a headline.
|
||||
level, banner = "bad", messages.banner_not_ready(bad[0])
|
||||
elif not self.auto:
|
||||
level, banner = "warn", "Stopped — inverter commanded to 0 W"
|
||||
elif any(i.delivery_wd.tripped for i in self.inverters):
|
||||
@@ -5194,12 +5094,8 @@ class Controller:
|
||||
# precisely the shape this whole card exists to remove. It sits
|
||||
# BELOW "Stopped" because a stopped site is the more urgent fact and
|
||||
# the banner carries one sentence.
|
||||
_nd = ", ".join(i.name for i in self.inverters
|
||||
if i.delivery_wd.tripped)
|
||||
level, banner = "warn", (
|
||||
f"NOT DELIVERING — {_nd} is standing at a share it is not "
|
||||
f"producing. The site is still running and short by it; "
|
||||
f"nothing has been commanded differently.")
|
||||
level, banner = "warn", messages.banner_not_delivering(
|
||||
[i.name for i in self.inverters if i.delivery_wd.tripped])
|
||||
elif self.maint.phase != IDLE:
|
||||
# ⚠️ THE PACK IS NAMED ONLY WHEN THERE IS MORE THAN ONE. At a roster
|
||||
# of one this is the string it has always been, character for
|
||||
@@ -5474,6 +5370,35 @@ def control_task_done(task: asyncio.Task, *, controller, stop: asyncio.Event,
|
||||
stop.set()
|
||||
|
||||
|
||||
DOCS_LINK_TIMEOUT_S = 3
|
||||
|
||||
|
||||
async def docs_link_facts(session, token: str) -> dict:
|
||||
"""`{slug, ha_version}` from the Supervisor, each None when unreadable.
|
||||
|
||||
`GET /addons/self/info` and `GET /info` are on the Supervisor's bypass
|
||||
list for an add-on's own token, so they need no role (see selfconfig.py).
|
||||
Asked together with a 3 s budget: a link may never hold up control start.
|
||||
"""
|
||||
async def ask(url, field):
|
||||
try:
|
||||
async with session.get(url, timeout=DOCS_LINK_TIMEOUT_S, headers={
|
||||
"Authorization": f"Bearer {token}"}) as r:
|
||||
body = await r.json(content_type=None)
|
||||
data = body.get("data", body) if isinstance(body, dict) else {}
|
||||
return data.get(field) if isinstance(data, dict) else None
|
||||
except Exception as err: # noqa: BLE001 - a link, never a stop
|
||||
_LOG.info("docs link: %s unreadable (%s)", url, err)
|
||||
return None
|
||||
|
||||
slug, ha = await asyncio.gather(
|
||||
ask("http://supervisor/addons/self/info", "slug"),
|
||||
ask("http://supervisor/info", "homeassistant"))
|
||||
out = {"slug": slug, "ha_version": ha}
|
||||
_LOG.info("docs link: slug %s, Home Assistant %s", slug, ha)
|
||||
return out
|
||||
|
||||
|
||||
async def amain() -> None:
|
||||
opts = load_options()
|
||||
logging.basicConfig(
|
||||
@@ -5505,6 +5430,12 @@ async def amain() -> None:
|
||||
except Exception as _e: # noqa: BLE001
|
||||
_LOG.error("core api probe failed: %s", _e)
|
||||
|
||||
# UX-09: the Details link in every notification needs this add-on's
|
||||
# slug and Home Assistant's version (see messages.docs_url()). Both
|
||||
# are best effort: without them the link falls back to the hostname,
|
||||
# or to naming the section only.
|
||||
messages.set_site(**await docs_link_facts(session, _tok))
|
||||
|
||||
# ⚠️ THE STARTUP GATE (CFG-01). Nothing below this line may run on a
|
||||
# configuration validate.py rejects - specs §1.5: a config the system
|
||||
# cannot honour is refused at startup, not survived at runtime.
|
||||
|
||||
@@ -37,25 +37,60 @@ def names(items) -> str:
|
||||
return ", ".join(items[:-1]) + " and " + items[-1]
|
||||
|
||||
|
||||
def addon_slug() -> str | None:
|
||||
"""This add-on's Supervisor slug, from the container hostname.
|
||||
# The Details link (UX-09). Home Assistant 2026.2 added the built-in `app`
|
||||
# panel (core #157554, frontend #28245), whose add-on pages are
|
||||
# /config/app/<slug>/<tab>. 2026.5 dropped the old `hassio` panel, so
|
||||
# /hassio/addon/<slug>/<tab> is a 404 there; 2026.1 and older have only that
|
||||
# one. No path reaches the Documentation tab on both, so the link follows the
|
||||
# Home Assistant version, and an unknown version gets the current path.
|
||||
DOCS_PATH = "/config/app/{slug}/documentation"
|
||||
DOCS_PATH_OLD = "/hassio/addon/{slug}/documentation"
|
||||
APP_PANEL_SINCE = (2026, 2)
|
||||
_SLUG = re.compile(r"[a-z0-9]+_goodwe_controller")
|
||||
_site = {"slug": None, "ha": None}
|
||||
|
||||
The Supervisor names an add-on's host after its slug with `_` spelled `-`
|
||||
(`local_goodwe_controller` -> `local-goodwe-controller`). Anything else,
|
||||
e.g. a test run, gets no link rather than a wrong one.
|
||||
|
||||
def set_site(slug=None, ha_version=None) -> None:
|
||||
"""What main.py read from the Supervisor at start: our slug, HA's version."""
|
||||
_site["slug"] = slug if isinstance(slug, str) and _SLUG.fullmatch(slug) \
|
||||
else None
|
||||
_site["ha"] = ha_version if isinstance(ha_version, str) else None
|
||||
|
||||
|
||||
def ha_release(version) -> tuple | None:
|
||||
"""`"2026.9.1"` -> `(2026, 9)`; None when it cannot be read."""
|
||||
m = re.match(r"(\d{4})\.(\d{1,2})\b", str(version or ""))
|
||||
return (int(m.group(1)), int(m.group(2))) if m else None
|
||||
|
||||
|
||||
def addon_slug() -> str | None:
|
||||
"""This add-on's Supervisor slug, or None outside an add-on.
|
||||
|
||||
The Supervisor's own answer (`GET /addons/self/info`) first. Failing that,
|
||||
the container hostname, which the Supervisor names after the slug with `_`
|
||||
spelled `-` (`local-goodwe-controller`). Anything else gets no link rather
|
||||
than a wrong one.
|
||||
"""
|
||||
if _site["slug"]:
|
||||
return _site["slug"]
|
||||
host = os.environ.get("HOSTNAME", "")
|
||||
if re.fullmatch(r"[a-z0-9]+-goodwe-controller", host):
|
||||
return host.replace("-", "_")
|
||||
return None
|
||||
|
||||
|
||||
def docs_url(slug: str, ha_version=None) -> str:
|
||||
release = ha_release(ha_version)
|
||||
old = release is not None and release < APP_PANEL_SINCE
|
||||
return (DOCS_PATH_OLD if old else DOCS_PATH).format(slug=slug)
|
||||
|
||||
|
||||
def details(title: str) -> str:
|
||||
where = f"section “{title}” under {DOCS_SECTION}"
|
||||
slug = addon_slug()
|
||||
if slug is None:
|
||||
return f"Details: add-on documentation, {where}."
|
||||
return (f"Details: [add-on documentation](/hassio/addon/{slug}/documentation),"
|
||||
return (f"Details: [add-on documentation]({docs_url(slug, _site['ha'])}),"
|
||||
f" {where}.")
|
||||
|
||||
|
||||
@@ -98,19 +133,22 @@ ID_NOT_DELIVERING = "goodwe_not_delivering_{slug}"
|
||||
ID_METER_FROZEN = "goodwe_meter_frozen"
|
||||
|
||||
# Which limit cut a command (clamp.ClampResult.bound, plus the loop's own).
|
||||
# The setting is named by its label, "Inverter rating (W)".
|
||||
RATING = "the “Inverter rating” setting"
|
||||
LIMIT_WORDS = {
|
||||
"max_w": "the configured inverter rating",
|
||||
"max_w": RATING,
|
||||
"device": "the inverter's own limit",
|
||||
"max_w+device": "the configured inverter rating and the inverter's own limit",
|
||||
"rating": "the inverter rating",
|
||||
"max_w+device": f"{RATING} and the inverter's own limit",
|
||||
"rating": RATING,
|
||||
}
|
||||
|
||||
|
||||
def loop_bound() -> Notice:
|
||||
"""SAFETY-40: the integrator bound. Normal in short bursts; not a fault."""
|
||||
return Notice(ID_LOOP_BOUND, WARNING, T_LOOP_BOUND,
|
||||
"The battery cannot give what the controller asks, which is "
|
||||
"normal for a moment but needs a check if it keeps happening.")
|
||||
"The battery gives less than asked, which is normal for a "
|
||||
"moment, but if it lasts, check it is on and not empty "
|
||||
"or full.")
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
@@ -122,77 +160,98 @@ class Clamp:
|
||||
limit: str # a key of LIMIT_WORDS
|
||||
|
||||
|
||||
def output_clamp(clamps) -> Notice:
|
||||
def output_clamp(clamps, *, shadow: bool = False) -> Notice:
|
||||
"""SAFETY-03: a computed command above the limit. A software fault.
|
||||
|
||||
Asked comes before sent, always - reading them the other way round turns
|
||||
the alarm backwards (test_clamp.py part 6).
|
||||
the alarm backwards (test_clamp.py part 6). In shadow mode the cut command
|
||||
never reached the inverter, so the text says "would have" (UX-09).
|
||||
"""
|
||||
fault = "This is a software fault, so please report it to your installer."
|
||||
if not clamps:
|
||||
cut = ("would have been cut back" if shadow else "was cut back")
|
||||
state = ("Shadow mode is on, so every inverter stays at 0 W." if shadow
|
||||
else "Control is still running.")
|
||||
return Notice(ID_OUTPUT_CLAMP, ALARM, T_OUTPUT_CLAMP,
|
||||
"The controller asked for more power than the inverter "
|
||||
"rating and was cut back. Control is still running. This "
|
||||
"is a software fault, so please report it to your "
|
||||
"installer.")
|
||||
f"The add-on asked for more power than {RATING} allows "
|
||||
f"and {cut}. {state} {fault}")
|
||||
c = clamps[0]
|
||||
who = f"For {c.unit}, the" if c.unit else "The"
|
||||
others = [x.unit for x in clamps[1:] if x.unit]
|
||||
running = (f"{names(others)} {'was' if len(others) == 1 else 'were'} cut "
|
||||
f"too, and control is still running." if others
|
||||
else "Control is still running.")
|
||||
sent = "would have sent" if shadow else "sent"
|
||||
if others:
|
||||
verb = "was" if len(others) == 1 else "were"
|
||||
state = (f"{names(others)} would have been cut too, and shadow mode "
|
||||
f"keeps every inverter at 0 W." if shadow else
|
||||
f"{names(others)} {verb} cut too, and control is still "
|
||||
f"running.")
|
||||
else:
|
||||
state = ("Shadow mode is on, so the inverter stays at 0 W." if shadow
|
||||
else "Control is still running.")
|
||||
return Notice(ID_OUTPUT_CLAMP, ALARM, T_OUTPUT_CLAMP,
|
||||
f"{who} controller asked for {watts(c.asked_w)}, above "
|
||||
f"{LIMIT_WORDS.get(c.limit, LIMIT_WORDS['rating'])}, and sent "
|
||||
f"{watts(c.sent_w)} instead. {running} "
|
||||
f"This is a software fault, so please report it to your "
|
||||
f"installer.")
|
||||
f"{who} add-on asked for {watts(c.asked_w)}, above "
|
||||
f"{LIMIT_WORDS.get(c.limit, RATING)}, and {sent} "
|
||||
f"{watts(c.sent_w)} instead. {state} {fault}")
|
||||
|
||||
|
||||
def peak_saturated(ceiling_w) -> Notice:
|
||||
"""SAFETY-07: the battery gives all it can and the peak still goes up."""
|
||||
def peak_saturated(ceiling_w, *, shadow: bool = False) -> Notice:
|
||||
"""SAFETY-07: the battery gives all it can and the peak still goes up.
|
||||
|
||||
In shadow mode the battery gives nothing, so the text says what the add-on
|
||||
would ask and that the peak may rise (UX-09).
|
||||
"""
|
||||
act = "Switch off large loads in the next few minutes."
|
||||
if shadow:
|
||||
return Notice(ID_PEAK_SATURATED, ALARM, T_PEAK_SATURATED,
|
||||
f"The add-on would ask the battery for all it can give, "
|
||||
f"and this 15-minute period is heading over your "
|
||||
f"{watts(ceiling_w)} peak limit. Shadow mode is on, so "
|
||||
f"the battery gives nothing and this month's peak may "
|
||||
f"rise. {act}")
|
||||
return Notice(ID_PEAK_SATURATED, ALARM, T_PEAK_SATURATED,
|
||||
f"The battery is giving all it can, but this 15-minute period "
|
||||
f"will still go over your {watts(ceiling_w)} peak limit and "
|
||||
f"raise this month's peak. Switch off large loads in the next "
|
||||
f"few minutes. This is not a fault: the load is bigger than "
|
||||
f"the inverter.")
|
||||
f"raise this month's peak. {act} This is not a fault: the "
|
||||
f"load is more than the battery can supply.")
|
||||
|
||||
|
||||
def peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
packs=()) -> Notice:
|
||||
"""SAFETY-24/25/32: the peak guard may not discharge any further.
|
||||
"""SAFETY-24/25/32: the peak guard may not draw the battery any lower.
|
||||
|
||||
The last sentence is SAFETY-25 and must stay: the reserve binds the peak
|
||||
guard only, and normal home use goes on discharging below it.
|
||||
guard only, and normal home use goes on drawing the battery below it.
|
||||
`packs` names the batteries at their limit, only on a site with several.
|
||||
`floor_unknown`: the floor the guard grades against is None, which at a
|
||||
roster means some inverter's cut-out level is missing (the peak reserve
|
||||
itself always has a value) - so the action names the cut-out level.
|
||||
Both are named by their setting labels, "Peak reserve (%)" and "Battery
|
||||
cut-out level (%)".
|
||||
"""
|
||||
if soc_unread:
|
||||
why = "The battery level cannot be read"
|
||||
act = "Switch off large loads, and check the battery level sensor."
|
||||
act = ("Switch off large loads, and check the “Battery level entity” "
|
||||
"setting.")
|
||||
elif floor_unknown:
|
||||
why = "The cut-out level of a battery is not known"
|
||||
act = ("Switch off large loads, and set each battery's cut-out level "
|
||||
"in the settings.")
|
||||
why = "A battery cut-out level is not known"
|
||||
act = ("Switch off large loads, and set “Battery cut-out level” for "
|
||||
"each inverter.")
|
||||
else:
|
||||
why = (f"The battery of {names(packs)} is at its peak reserve" if packs
|
||||
else "The battery is at its peak reserve")
|
||||
act = ("Switch off large loads, or lower the peak reserve if the "
|
||||
"battery allows it.")
|
||||
act = "Switch off large loads, or lower the peak reserve."
|
||||
return Notice(ID_PEAK_RESERVE, ALARM, T_PEAK_RESERVE,
|
||||
f"{why}, so this 15-minute period will go over your "
|
||||
f"{watts(ceiling_w)} peak limit and raise this month's peak. "
|
||||
f"{act} The reserve only applies to keeping the peak down: normal home use "
|
||||
f"can still discharge the battery below it, down to its "
|
||||
f"cut-out level.")
|
||||
f"{act} The reserve only applies to keeping the peak down: "
|
||||
f"normal home use can still draw the battery below it, down "
|
||||
f"to the battery cut-out level.")
|
||||
|
||||
|
||||
def circulating(discharging=(), charging=()) -> Notice:
|
||||
"""SAFETY-31: the inverters push power round each other. Control stopped."""
|
||||
if discharging and charging:
|
||||
what = (f"{names(discharging)} was discharging while "
|
||||
what = (f"{names(discharging)} was giving power while "
|
||||
f"{names(charging)} was charging, and your meter cannot see "
|
||||
f"this.")
|
||||
else:
|
||||
@@ -222,12 +281,497 @@ def meter_frozen(unchanged_s) -> Notice:
|
||||
"""SAFETY-18: the meter answers but its value does not move."""
|
||||
return Notice(ID_METER_FROZEN, ALARM, T_METER_FROZEN,
|
||||
f"The meter has shown the same value for "
|
||||
f"{duration(unchanged_s)} while the controller asks the "
|
||||
f"{duration(unchanged_s)} while the add-on asks the "
|
||||
f"battery for full power. Control is still running and still "
|
||||
f"follows this reading. Check the meter, and if it is stuck, "
|
||||
f"stop control on the add-on page.")
|
||||
|
||||
|
||||
# --- the status page (UX-08 phase 2b) ----------------------------------------
|
||||
# The rows of the Commissioning list and the banner at the top of the add-on
|
||||
# page. `main.py` decides WHEN a row shows and its colour (ok / warn / bad);
|
||||
# these decide WHAT it says. A row is one sentence of at most 15 words; a red
|
||||
# row may use up to 3 sentences and 30 words. A banner is at most 12 words.
|
||||
# Rows never name a Home Assistant entity: they name the setting in words.
|
||||
# DOCS.md, "Status page", explains every row.
|
||||
|
||||
NOT_READY = "Not ready"
|
||||
DOCS_STATUS = "Status page"
|
||||
|
||||
|
||||
def signed_watts(value) -> str:
|
||||
"""`-1200` -> `-1 200 W`: like `watts()`, but the sign is kept."""
|
||||
return f"{float(value):,.0f} W".replace(",", " ")
|
||||
|
||||
|
||||
def seconds(value) -> str:
|
||||
"""Always in seconds, for a live count set against its limit."""
|
||||
n = f"{float(value):.0f}"
|
||||
return f"{n} second" if n == "1" else f"{n} seconds"
|
||||
|
||||
|
||||
def times(n) -> str:
|
||||
return "1 time" if int(n) == 1 else f"{int(n)} times"
|
||||
|
||||
|
||||
def for_unit(unit) -> str:
|
||||
"""` for inverter-b` on a site with several inverters, else nothing."""
|
||||
return f" for {unit}" if unit else ""
|
||||
|
||||
|
||||
def headline(text: str) -> str:
|
||||
"""The first sentence of a row, for the banner when the row has no own."""
|
||||
first = re.split(r"(?<=[.!?])\s+(?=[A-Z0-9])", text.strip(), maxsplit=1)[0]
|
||||
return first.rstrip(".")
|
||||
|
||||
|
||||
# Banners (the headline at the top of the page).
|
||||
def banner_not_ready(row: dict) -> str:
|
||||
return f"{NOT_READY} — {row.get('banner') or headline(row['text'])}"
|
||||
|
||||
|
||||
def banner_circulating() -> str:
|
||||
return "Inverters worked against each other. Every inverter is set to 0 W."
|
||||
|
||||
|
||||
def banner_site_direction() -> str:
|
||||
return "Total command and meter point opposite ways. All inverters at 0 W."
|
||||
|
||||
|
||||
def banner_direction(several: bool) -> str:
|
||||
if several:
|
||||
return "An inverter's own power opposes its command. It is at 0 W."
|
||||
return "Command and meter point opposite ways. Inverter set to 0 W."
|
||||
|
||||
|
||||
def banner_not_delivering(units) -> str:
|
||||
units = list(units)
|
||||
verb = "are" if len(units) > 1 else "is"
|
||||
return f"{names(units)} {verb} not delivering. Control keeps running."
|
||||
|
||||
|
||||
def banner_shadow(latched: bool) -> str:
|
||||
"""SAFETY-10: first in the cascade, never displaced by another banner.
|
||||
|
||||
With a safety stop standing it goes red and says the stop outlasts shadow
|
||||
mode. Each stop has its own red row below, which names it and says how it
|
||||
clears.
|
||||
"""
|
||||
if latched:
|
||||
return ("Shadow mode: battery not controlled. A safety stop stays on, "
|
||||
"see below.")
|
||||
return "Shadow mode: the battery is not controlled. Inverters stay at 0 W."
|
||||
|
||||
|
||||
# Rows: control and the meter. "Control" is what the add-on does, as in
|
||||
# "start control" (STYLE.md section 4).
|
||||
def row_controller_starting() -> str:
|
||||
return "Control: starting"
|
||||
|
||||
|
||||
def row_controller_ran(age_s) -> str:
|
||||
return f"Control: last ran {seconds(age_s)} ago"
|
||||
|
||||
|
||||
def row_controller_stalled(age_s, veto_s) -> str:
|
||||
return (f"Control has not run for {seconds(age_s)}. The control board "
|
||||
f"sets the inverter to 0 W after {seconds(veto_s)}.")
|
||||
|
||||
|
||||
def row_meter_stale(age_s, limit_s) -> str:
|
||||
return (f"Meter: no reading for {seconds(age_s)}, limit "
|
||||
f"{seconds(limit_s)}. The add-on log shows why.")
|
||||
|
||||
|
||||
def row_meter(net_w, age_s, rejected=0, unchanged_s=None) -> str:
|
||||
return (f"Meter: {signed_watts(net_w)}, {seconds(age_s)} old"
|
||||
+ (f", {rejected} readings refused" if rejected else "")
|
||||
+ ("" if unchanged_s is None
|
||||
else f", unchanged for {duration(unchanged_s)}"))
|
||||
|
||||
|
||||
def row_meter_frozen() -> str:
|
||||
return (f"{T_METER_FROZEN}. Control still follows it. Check the meter, "
|
||||
f"and stop control if it is stuck.")
|
||||
|
||||
|
||||
# Settings are named by their labels in translations/en.yaml.
|
||||
METER_SOURCE = "“Where the meter reading comes from”"
|
||||
|
||||
FREEZE_OFF = {
|
||||
"source": f"it needs {METER_SOURCE} set to HomeWizard local",
|
||||
"rating": "“Inverter rating” is not set",
|
||||
"range": "the inverter reports no usable power range",
|
||||
}
|
||||
|
||||
|
||||
def row_freeze_off(why: str) -> str:
|
||||
"""`why` is a key of FREEZE_OFF: why the stuck-meter check cannot run."""
|
||||
return f"Stuck-meter check: off, {FREEZE_OFF[why]}"
|
||||
|
||||
|
||||
def row_freeze_on(hold_s, rail_w, own_limit: bool) -> str:
|
||||
return (f"Stuck-meter check: alerts after {duration(hold_s)} unchanged "
|
||||
f"above {watts(rail_w)}"
|
||||
+ (", the inverter's own limit" if own_limit else ""))
|
||||
|
||||
|
||||
# Rows: the peak guard.
|
||||
def row_peak_saturated(ceiling_w) -> str:
|
||||
return (f"{T_PEAK_SATURATED}. Switch off large loads to stay under the "
|
||||
f"{watts(ceiling_w)} peak limit.")
|
||||
|
||||
|
||||
def row_peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
packs=()) -> str:
|
||||
"""SAFETY-24/25/32. The second sentence is SAFETY-25 and must stay."""
|
||||
if soc_unread:
|
||||
why = "Battery level cannot be read"
|
||||
elif floor_unknown:
|
||||
why = "A battery cut-out level is not set"
|
||||
else:
|
||||
why = (f"{names(packs)} battery at its peak reserve" if packs
|
||||
else "Battery at its peak reserve")
|
||||
return (f"{why}, so the {watts(ceiling_w)} peak limit will be passed. Home "
|
||||
f"use still draws the battery below it, down to the cut-out level.")
|
||||
|
||||
|
||||
def row_peak_guard_off() -> str:
|
||||
"""`meter_source` is off: the 15-minute average cannot be measured."""
|
||||
return f"Peak guard: off, set {METER_SOURCE} to anything but off"
|
||||
|
||||
|
||||
def banner_peak_reserve() -> str:
|
||||
return T_PEAK_RESERVE
|
||||
|
||||
|
||||
# Rows: the sensors and the inverter control.
|
||||
LABEL_SOC = "Battery level"
|
||||
LABEL_BATTERY = "Battery power"
|
||||
LABEL_GRID = "Grid power"
|
||||
|
||||
|
||||
def row_sensor(label, value, unit=None) -> str:
|
||||
shown = f"{float(value):g} %" if label.startswith(LABEL_SOC) \
|
||||
else signed_watts(value)
|
||||
return f"{label}{for_unit(unit)}: {shown}"
|
||||
|
||||
|
||||
def row_sensor_unset(label, unit=None) -> str:
|
||||
"""The setting is "<label> entity" (e.g. "Grid power entity (W)")."""
|
||||
return f"{label}{for_unit(unit)}: “{label} entity” is not set"
|
||||
|
||||
|
||||
def row_sensor_unusable(label, unit=None) -> str:
|
||||
"""SAFETY-56: it may be missing OR held back as stale; say both."""
|
||||
return (f"{label}{for_unit(unit)}: no usable reading. The entity may be "
|
||||
f"missing, or its reading is held back as too old. Check it in "
|
||||
f"Developer Tools before replacing it.")
|
||||
|
||||
|
||||
def setpoint_label(unit=None) -> str:
|
||||
"""The label: "Setpoint entity" in the inverter list, else its long form."""
|
||||
return "“Setpoint entity”" if unit else "“Inverter setpoint entity”"
|
||||
|
||||
|
||||
def row_control_unset(unit=None) -> str:
|
||||
return f"Inverter control{for_unit(unit)}: {setpoint_label(unit)} is not set"
|
||||
|
||||
|
||||
def row_control_missing(unit=None) -> str:
|
||||
return f"Inverter control{for_unit(unit)}: not found in Home Assistant"
|
||||
|
||||
|
||||
# Rows: whether each inverter can still be controlled (DEV-02). `name` is
|
||||
# always given: these rows came with the inverter list.
|
||||
def row_no_setpoint(name) -> str:
|
||||
"""Amber. The site refuses to run at part strength, so all stay at 0 W."""
|
||||
return f"{name}: “Setpoint entity” is not set, so every inverter stays at 0 W"
|
||||
|
||||
|
||||
def row_not_controllable(name, held_s, limit_s) -> str:
|
||||
"""Red. The inverter is dropped and the others carry its share."""
|
||||
return (f"{name} cannot be controlled. It refused every command for "
|
||||
f"{seconds(held_s)}, so control leaves it out.")
|
||||
|
||||
|
||||
def row_commands_refused(name, held_s, limit_s) -> str:
|
||||
"""Amber. Refused, but not for long enough to be dropped yet."""
|
||||
return (f"{name}: commands refused for {seconds(held_s)}, left out of "
|
||||
f"control after {seconds(limit_s)}")
|
||||
|
||||
|
||||
def row_control(lo_w, hi_w, unit=None) -> str:
|
||||
def w(v):
|
||||
return "?" if v is None else signed_watts(v)
|
||||
return f"Inverter control{for_unit(unit)}: ready, from {w(lo_w)} to {w(hi_w)}"
|
||||
|
||||
|
||||
# Rows: the two loop alarms. The names are the notification titles, so the
|
||||
# row and the card always call the same thing by the same name (UX-07 item 1).
|
||||
def row_power_too_high(clamps, count, *, shadow: bool = False) -> str:
|
||||
"""In shadow mode nothing was sent, so it says "would send" (UX-09)."""
|
||||
c = clamps[0] if clamps else None
|
||||
head = f"{T_OUTPUT_CLAMP}{' in shadow mode' if shadow else ''}"
|
||||
what = (f"asked {watts(c.asked_w)}{for_unit(c.unit)}, "
|
||||
f"{'would send' if shadow else 'sent'} {watts(c.sent_w)}. Cut back"
|
||||
if c else "cut back")
|
||||
return (f"{head}: {what} {times(count)} since start. Software fault, "
|
||||
f"please report it.")
|
||||
|
||||
|
||||
def banner_power_too_high() -> str:
|
||||
return T_OUTPUT_CLAMP
|
||||
|
||||
|
||||
def row_not_keeping_up(count) -> str:
|
||||
return f"{T_LOOP_BOUND}: {times(count)} since start"
|
||||
|
||||
|
||||
def row_before(title, count) -> str:
|
||||
"""After an episode clears: how often it happened, so the evidence stays."""
|
||||
return f"{title}: {times(count)} since start, fine now"
|
||||
|
||||
|
||||
def row_write_refused(unit=None) -> str:
|
||||
return (f"{unit or 'The inverter'} refused the last command. Check the "
|
||||
f"add-on log.")
|
||||
|
||||
|
||||
# Rows: the direction checks (SAFETY-02/30).
|
||||
def row_direction_trip(unit=None) -> str:
|
||||
"""Per inverter. `unit` only at several inverters, graded on its own power."""
|
||||
what = (f"{unit}: command and its own power point opposite ways, so it is"
|
||||
if unit else "Command and meter point opposite ways, so the "
|
||||
"inverter is")
|
||||
return (f"{what} set to 0 W. Find out why, then start control. A restart "
|
||||
f"does not clear this.")
|
||||
|
||||
|
||||
def row_direction_check(held_s, hold_s, unit=None) -> str:
|
||||
who = (f"Direction check for {unit}, against its own power" if unit
|
||||
else "Direction check")
|
||||
if held_s:
|
||||
return f"{who}: opposite for {held_s:.0f} of {seconds(hold_s)}"
|
||||
return f"{who}: on"
|
||||
|
||||
|
||||
def row_site_direction_trip() -> str:
|
||||
return ("Total command and meter point opposite ways, so every inverter is "
|
||||
"set to 0 W. The cause is the total, not one inverter. Only starting "
|
||||
"control clears this.")
|
||||
|
||||
|
||||
def row_site_direction_check(held_s, hold_s) -> str:
|
||||
if held_s:
|
||||
return (f"Site direction check: opposite for {held_s:.0f} of "
|
||||
f"{seconds(hold_s)}")
|
||||
return "Site direction check: on, against the meter"
|
||||
|
||||
|
||||
# Rows: circulating power (SAFETY-31) and delivery (SAFETY-42).
|
||||
def row_circulating_trip() -> str:
|
||||
return ("Inverters worked against each other, so every inverter is set to "
|
||||
"0 W. The meter cannot see this. Only starting control clears this.")
|
||||
|
||||
|
||||
def row_circulating_check(now_w, held_s, hold_s) -> str:
|
||||
return ("Circulating power check: on"
|
||||
+ (f", now {watts(now_w)}" if now_w else "")
|
||||
+ (f", for {held_s:.0f} of {seconds(hold_s)}" if held_s else ""))
|
||||
|
||||
|
||||
def row_one_inverter(check: str) -> str:
|
||||
return f"{check}: not needed with one inverter"
|
||||
|
||||
|
||||
def row_not_delivering(unit) -> str:
|
||||
return (f"{unit} is not delivering, and only stopping and starting control "
|
||||
f"clears this")
|
||||
|
||||
|
||||
def row_delivery_check(unit, short_s, hold_s) -> str:
|
||||
if short_s:
|
||||
return (f"Delivery check for {unit}: short for {short_s:.0f} of "
|
||||
f"{seconds(hold_s)}")
|
||||
return f"Delivery check for {unit}: on"
|
||||
|
||||
|
||||
def row_estop_fitted() -> str:
|
||||
return "Emergency stop: fitted"
|
||||
|
||||
|
||||
def row_no_peak_forecast() -> str:
|
||||
return ("No peak forecast set, so maintenance charging is not kept under "
|
||||
"the peak limit")
|
||||
|
||||
|
||||
def row_peak_guard_waiting() -> str:
|
||||
return "Peak guard: no decision yet, control has not run"
|
||||
|
||||
|
||||
def row_no_estop() -> str:
|
||||
return ("No emergency stop fitted: if this computer fails, the battery "
|
||||
"keeps its last command")
|
||||
|
||||
|
||||
# Rows: solar production (TEL-11/12/14). Sources are numbered in the order of
|
||||
# "Solar production entities, per inverter". The settings are named by their
|
||||
# labels in translations/en.yaml.
|
||||
PV_ONE = "“Solar production entity”"
|
||||
PV_REVERSED = "“Reversed-sign solar entities”"
|
||||
|
||||
|
||||
def source(n, of) -> str:
|
||||
return "the entity" if of == 1 else f"source {n}"
|
||||
|
||||
|
||||
def pv_problem(why: str) -> str:
|
||||
"""`pv.watts()`'s reason, in plain words."""
|
||||
w = str(why)
|
||||
if w.startswith("no state"):
|
||||
return "the entity is missing"
|
||||
if w.startswith("entity is"):
|
||||
return "the entity is unavailable"
|
||||
if w.endswith("is not numeric"):
|
||||
return "the reading is not a number"
|
||||
if w.startswith("no unit"):
|
||||
return "the entity has no unit"
|
||||
if w.startswith("unit "):
|
||||
return "the entity's unit is not a power unit"
|
||||
return "the reading is not usable"
|
||||
|
||||
|
||||
def row_pv(total_w, count, reversed_=False) -> str:
|
||||
return (f"Solar production: {signed_watts(total_w)}"
|
||||
+ (f" from {count} sources" if count > 1 else "")
|
||||
+ (", sign reversed" if reversed_ else ""))
|
||||
|
||||
|
||||
def row_pv_none(why) -> str:
|
||||
return f"Solar production: no reading, {pv_problem(why)}"
|
||||
|
||||
|
||||
def row_pv_partial(missing, count) -> str:
|
||||
"""`missing` are the 1-based positions of the sources that did not report."""
|
||||
which = names([str(n) for n in missing])
|
||||
return (f"Solar production: no total, source{'s' if len(missing) > 1 else ''} "
|
||||
f"{which} of {count} {'have' if len(missing) > 1 else 'has'} no "
|
||||
f"reading")
|
||||
|
||||
|
||||
def row_pv_single_ignored() -> str:
|
||||
return f"Solar production: clear {PV_ONE}, the per-inverter list replaces it"
|
||||
|
||||
|
||||
def row_pv_negative(n, count, value_w, flipped: bool) -> str:
|
||||
fix = ("remove it from" if flipped else "add it to")
|
||||
who = source(n, count)
|
||||
return (f"Solar production: {who} reads {signed_watts(value_w)}, "
|
||||
f"{fix} {PV_REVERSED}")
|
||||
|
||||
|
||||
def row_pv_stray(n) -> str:
|
||||
return (f"Solar production: entry {n} of {PV_REVERSED} is not a solar "
|
||||
f"entity in use")
|
||||
|
||||
|
||||
RED, AMBER, GREEN = "bad", "warn", "ok"
|
||||
|
||||
|
||||
def status_samples() -> list:
|
||||
"""`(function name, colour, text)` for every row and banner, for the test.
|
||||
|
||||
The colour is the one main.py gives the row; a red row may use three
|
||||
sentences. Banners are listed with the colour None.
|
||||
"""
|
||||
clamp = [Clamp(None, 7412, 5000, "rating")]
|
||||
return [
|
||||
("banner_not_ready", None, banner_not_ready(
|
||||
{"text": row_meter_frozen()})),
|
||||
("banner_not_ready", None, banner_not_ready(
|
||||
{"text": "x", "banner": banner_peak_reserve()})),
|
||||
("banner_circulating", None, banner_circulating()),
|
||||
("banner_site_direction", None, banner_site_direction()),
|
||||
("banner_direction", None, banner_direction(False)),
|
||||
("banner_direction", None, banner_direction(True)),
|
||||
("banner_not_delivering", None, banner_not_delivering(["inverter-b"])),
|
||||
("banner_peak_reserve", None, banner_peak_reserve()),
|
||||
("banner_power_too_high", None, banner_power_too_high()),
|
||||
("banner_shadow", None, banner_shadow(False)),
|
||||
("banner_shadow", None, banner_shadow(True)),
|
||||
("row_controller_starting", GREEN, row_controller_starting()),
|
||||
("row_controller_ran", GREEN, row_controller_ran(2)),
|
||||
("row_controller_stalled", RED, row_controller_stalled(45, 30)),
|
||||
("row_meter_stale", RED, row_meter_stale(40, 10)),
|
||||
("row_meter", GREEN, row_meter(-350, 2, 3, 340)),
|
||||
("row_meter_frozen", RED, row_meter_frozen()),
|
||||
*(("row_freeze_off", AMBER, row_freeze_off(k)) for k in FREEZE_OFF),
|
||||
("row_freeze_on", GREEN, row_freeze_on(600, 4465, True)),
|
||||
("row_peak_saturated", RED, row_peak_saturated(5000)),
|
||||
("row_peak_guard_off", AMBER, row_peak_guard_off()),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=False, floor_unknown=False, packs=["inverter-b"])),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=True, floor_unknown=False)),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=False, floor_unknown=True)),
|
||||
("row_sensor", GREEN, row_sensor(LABEL_SOC, 54, "inverter-b")),
|
||||
("row_sensor", GREEN, row_sensor(LABEL_BATTERY, -1200.0, "inverter-b")),
|
||||
("row_sensor_unset", RED, row_sensor_unset(LABEL_GRID)),
|
||||
("row_sensor_unusable", RED, row_sensor_unusable(LABEL_BATTERY,
|
||||
"inverter-b")),
|
||||
("row_control_unset", RED, row_control_unset("inverter-b")),
|
||||
("row_control_missing", RED, row_control_missing("inverter-b")),
|
||||
("row_control", GREEN, row_control(-5000, 5000, "inverter-b")),
|
||||
("row_control_unset", RED, row_control_unset()),
|
||||
("row_no_setpoint", AMBER, row_no_setpoint("inverter-b")),
|
||||
("row_not_controllable", RED, row_not_controllable("inverter-b", 45,
|
||||
30)),
|
||||
("row_commands_refused", AMBER, row_commands_refused("inverter-b", 12,
|
||||
30)),
|
||||
("row_power_too_high", RED, row_power_too_high(clamp, 3)),
|
||||
("row_power_too_high", RED, row_power_too_high(
|
||||
[Clamp("inverter-b", 6000, 4600, "max_w+device")], 12)),
|
||||
("row_power_too_high", RED, row_power_too_high((), 1)),
|
||||
("row_power_too_high", RED, row_power_too_high(
|
||||
[Clamp("inverter-b", 6000, 4600, "max_w+device")], 12,
|
||||
shadow=True)),
|
||||
("row_not_keeping_up", AMBER, row_not_keeping_up(48)),
|
||||
("row_before", AMBER, row_before(T_OUTPUT_CLAMP, 2)),
|
||||
("row_before", AMBER, row_before(T_LOOP_BOUND, 1)),
|
||||
("row_write_refused", RED, row_write_refused("inverter-b")),
|
||||
("row_direction_trip", RED, row_direction_trip()),
|
||||
("row_direction_trip", RED, row_direction_trip("inverter-b")),
|
||||
("row_direction_check", GREEN, row_direction_check(0, 60)),
|
||||
("row_direction_check", GREEN, row_direction_check(12, 60,
|
||||
"inverter-b")),
|
||||
("row_site_direction_trip", RED, row_site_direction_trip()),
|
||||
("row_site_direction_check", GREEN, row_site_direction_check(0, 60)),
|
||||
("row_site_direction_check", GREEN, row_site_direction_check(5, 60)),
|
||||
("row_circulating_trip", RED, row_circulating_trip()),
|
||||
("row_circulating_check", GREEN, row_circulating_check(1200, 20, 60)),
|
||||
("row_one_inverter", GREEN, row_one_inverter("Delivery check")),
|
||||
("row_not_delivering", AMBER, row_not_delivering("inverter-b")),
|
||||
("row_delivery_check", GREEN, row_delivery_check("inverter-b", 30, 120)),
|
||||
("row_delivery_check", GREEN, row_delivery_check("inverter-b", 0, 120)),
|
||||
("row_no_estop", AMBER, row_no_estop()),
|
||||
("row_estop_fitted", GREEN, row_estop_fitted()),
|
||||
("row_no_peak_forecast", AMBER, row_no_peak_forecast()),
|
||||
("row_peak_guard_waiting", AMBER, row_peak_guard_waiting()),
|
||||
("row_pv", GREEN, row_pv(3200, 2)),
|
||||
("row_pv", GREEN, row_pv(1800, 1, True)),
|
||||
("row_pv_none", AMBER, row_pv_none("no unit_of_measurement on the "
|
||||
"entity - it cannot be read in watts")),
|
||||
("row_pv_partial", AMBER, row_pv_partial([2, 3], 3)),
|
||||
("row_pv_partial", AMBER, row_pv_partial([2], 2)),
|
||||
("row_pv_single_ignored", AMBER, row_pv_single_ignored()),
|
||||
("row_pv_negative", AMBER, row_pv_negative(2, 3, -1500, False)),
|
||||
("row_pv_negative", AMBER, row_pv_negative(1, 1, -1500, True)),
|
||||
("row_pv_stray", AMBER, row_pv_stray(2)),
|
||||
]
|
||||
|
||||
|
||||
def samples() -> list:
|
||||
"""One rendering of every notice, with realistic values, for the test."""
|
||||
return [
|
||||
@@ -236,7 +780,13 @@ def samples() -> list:
|
||||
output_clamp(()),
|
||||
output_clamp([Clamp("inverter-a", -3000, -2500, "device"),
|
||||
Clamp("inverter-b", 6000, 4600, "max_w+device")]),
|
||||
output_clamp([Clamp(None, 7412, 5000, "rating")], shadow=True),
|
||||
output_clamp((), shadow=True),
|
||||
output_clamp([Clamp("inverter-a", -3000, -2500, "device"),
|
||||
Clamp("inverter-b", 6000, 4600, "max_w+device")],
|
||||
shadow=True),
|
||||
peak_saturated(5000),
|
||||
peak_saturated(5000, shadow=True),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False,
|
||||
packs=["inverter-b"]),
|
||||
|
||||
@@ -279,6 +279,8 @@ that write is issued rather than skipped as unchanged.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
from . import messages
|
||||
|
||||
# ⚠️ CFG-03's mirror. `test_defaults_pin.py` part 2 discovers every
|
||||
# module-level name ending in OPTION_DEFAULTS and asserts each value
|
||||
# reproduces config.yaml EXACTLY, so this table cannot drift from the shipped
|
||||
@@ -471,25 +473,17 @@ def log_line(*, would_w: float, reason: str, sized_from_meter: bool) -> str:
|
||||
def banner(opts: dict, *, control_started: bool, latched: tuple = ()) -> tuple:
|
||||
"""`(level, text)` for the top of the status page, or `None` when live.
|
||||
|
||||
⚠️ IT NAMES A STANDING LATCH AND GOES RED FOR ONE. The shadow banner sits
|
||||
ABOVE every other branch of the cascade, because "the battery is not being
|
||||
controlled" is the one sentence that may never be displaced - but a
|
||||
failsafe latch that is up while the controller is inert is up when it
|
||||
stops being inert, and an operator who turns shadow mode off without
|
||||
clearing it gets a battery that will not move and a green page that
|
||||
never mentioned why. So the latch is carried INTO the shadow banner
|
||||
rather than losing its own.
|
||||
⚠️ IT GOES RED FOR A STANDING LATCH. The shadow banner sits ABOVE every
|
||||
other branch of the cascade, because "the battery is not controlled" is
|
||||
the one sentence that may never be displaced - but a failsafe latch that
|
||||
is up while the controller is inert is up when it stops being inert. So the
|
||||
banner says a safety stop outlasts shadow mode, and each latch keeps its
|
||||
own red row below, which names it and says how it clears. The words are
|
||||
`messages.banner_shadow()`'s (UX-09); `latched` names them for callers.
|
||||
"""
|
||||
if not engaged(opts, control_started=control_started):
|
||||
return None
|
||||
text = ("SHADOW MODE - the battery is NOT being controlled. Every "
|
||||
f"inverter is held at {WIRE_W:.0f} W and nothing this add-on "
|
||||
"decides reaches the inverter.")
|
||||
if latched:
|
||||
return ("bad", text + " ⚠️ A FAILSAFE LATCH IS STILL UP ("
|
||||
+ ", ".join(latched) + ") and it will still be up when shadow "
|
||||
"mode is turned off.")
|
||||
return ("warn", text)
|
||||
return ("bad" if latched else "warn", messages.banner_shadow(bool(latched)))
|
||||
|
||||
|
||||
def problems(opts: dict) -> list:
|
||||
|
||||
@@ -85,7 +85,8 @@ from named_absence import given, nth, present
|
||||
|
||||
from app import messages
|
||||
from app.clamp import (
|
||||
CLEAR_CYCLES, REASON_CODE, REASSERT_S, SUSTAINED_CYCLES, ClampWatchdog,
|
||||
CLEAR_CYCLES, REASON_CODE, REASSERT_S, SUSTAINED_CYCLES, ClampResult,
|
||||
ClampWatchdog,
|
||||
clamp_to_rating,
|
||||
is_commandable,
|
||||
)
|
||||
@@ -541,11 +542,38 @@ check("...and the count in the row is the counter's, so nothing is lost",
|
||||
# is captured mid-run rather than asserted after the hysteresis has cleared it.
|
||||
check("the status page flags it WHILE it is engaged - amber, since it is the "
|
||||
"integrator bound (SAFETY-40; red is part 9's over-rating case)",
|
||||
any(not c["ok"] and c["warn"] and "LOOP AT INTEGRATOR BOUND" in c["text"]
|
||||
any(not c["ok"] and c["warn"] and c.get("id") == "not_keeping_up"
|
||||
and c["text"].startswith(messages.T_LOOP_BOUND)
|
||||
for c in ctl_r.red_snapshot))
|
||||
check("...and once clear, a warn row still says how many times it engaged",
|
||||
any(c["warn"] and f"{ctl_r.clamp_wd.engagements} time(s)" in c["text"]
|
||||
for c in ctl_r.checks()))
|
||||
check("...and once clear, a warn row still says how many times it engaged, "
|
||||
"under the integrator bound's own title",
|
||||
any(c["warn"] and c.get("id") == "not_keeping_up"
|
||||
and c["text"].startswith(messages.T_LOOP_BOUND)
|
||||
and messages.times(ctl_r.clamp_wd.bound) in c["text"]
|
||||
and "fine now" in c["text"] for c in ctl_r.checks()))
|
||||
# UX-07 item 1: the after-episode row used to say "output clamp ... engaged N
|
||||
# time(s)" for integrator-bound cycles. Each count now sits under its own name.
|
||||
check("UX-07 item 1: bound-only engagements are counted as the bound, and no "
|
||||
"row calls them 'Power request too high'",
|
||||
ctl_r.clamp_wd.bound == ctl_r.clamp_wd.engagements > 0
|
||||
and ctl_r.clamp_wd.over_rating == 0
|
||||
and not any(c.get("id") == "power_too_high"
|
||||
or messages.T_OUTPUT_CLAMP in c["text"]
|
||||
for c in ctl_r.checks()))
|
||||
# ...and an earlier over-rating count stays on the page while a LATER bound
|
||||
# episode runs: it is the software-fault evidence, and that episode (bug False)
|
||||
# cannot have added to it, so "fine now" is true of it.
|
||||
_w = ctl_r.clamp_wd
|
||||
_saved = (_w.active, _w.bug, _w.over_rating)
|
||||
_w.active, _w.bug, _w.over_rating = True, False, 2
|
||||
_rows = ctl_r.checks()
|
||||
_w.active, _w.bug, _w.over_rating = _saved
|
||||
check("UX-07 item 1: during a bound episode an earlier over-rating count is "
|
||||
"still shown, amber, under its own title",
|
||||
any(c.get("id") == "not_keeping_up" for c in _rows)
|
||||
and any(c.get("id") == "power_too_high" and c["warn"] and not c["ok"]
|
||||
and c["text"] == messages.row_before(messages.T_OUTPUT_CLAMP, 2)
|
||||
for c in _rows))
|
||||
|
||||
# ⚠️ NOT A TRIP. 11.2's action is "clamp and alarm"; the loop keeps running and
|
||||
# keeps writing the clamped value. If a later cut changes that it must come here.
|
||||
@@ -592,7 +620,8 @@ check("AC 2: the clamp counted ZERO engagements", ctl_s.clamp_wd.engagements ==
|
||||
check("AC 2: no OUTPUT_CLAMP row in the action log",
|
||||
not [e for e in ctl_s.events if REASON_CODE in e])
|
||||
check("AC 2: and no clamp row on the status page",
|
||||
not [c for c in ctl_s.checks() if "output clamp" in c["text"].lower()])
|
||||
not [c for c in ctl_s.checks()
|
||||
if c.get("id") in ("power_too_high", "not_keeping_up")])
|
||||
|
||||
print(" ...and the two alarms do not share a notification_id")
|
||||
ids_clamp = {d["notification_id"] for d in clamp_notes(hass_r)}
|
||||
@@ -1723,6 +1752,35 @@ check("SAFETY-28's gate still OBSERVES too - it refused nothing on this run, "
|
||||
"implemented by making every write unauthorised",
|
||||
not [e for e in _cl_c.events if "WRITE REFUSED" in e])
|
||||
|
||||
# UX-09: what the over-rating alarm and its row SAY in each mode. The loop
|
||||
# bounds the command before the write clamp here, so an over-rating is injected
|
||||
# as the write path records one, and check_output_clamp() is run on it. Nothing
|
||||
# reaches the wire in shadow mode, so neither text may claim a command was sent.
|
||||
def _said(mode):
|
||||
h, c = _s10(mode, cycles=2)
|
||||
c.inverters[0].clamp_last = ClampResult(7412.0, 5000.0, 5000.0, True,
|
||||
"max_w")
|
||||
asyncio.run(c.check_output_clamp())
|
||||
notes = [d["message"] for d in clamp_notes(h)
|
||||
if d["notification_id"] == CLAMP_ID]
|
||||
rows = [r["text"] for r in c.checks() if r.get("id") == "power_too_high"]
|
||||
return notes, rows
|
||||
|
||||
|
||||
_ux_live, _ux_shad = _said("off"), _said("on")
|
||||
print(f" over-rating, live: {_ux_live}\n over-rating, shadow: {_ux_shad}")
|
||||
check("UX-09: live, the over-rating alarm and row say what was SENT",
|
||||
_ux_live[0] and all(" and sent 5 000 W" in m for m in _ux_live[0])
|
||||
and _ux_live[1] and all("sent 5 000 W" in t and "would" not in t
|
||||
for t in _ux_live[1]))
|
||||
check("...in shadow mode they say what WOULD have been sent and that the "
|
||||
"inverter stays at 0 W, never that it was sent",
|
||||
_ux_shad[0] and all("would have sent 5 000 W" in m
|
||||
and " and sent " not in m and "stays at 0 W" in m
|
||||
for m in _ux_shad[0])
|
||||
and _ux_shad[1] and all("would send 5 000 W" in t and " sent " not in t
|
||||
for t in _ux_shad[1]))
|
||||
|
||||
# ⚠️ AND SAFETY-18 IS GRADED ON WHAT IT WAS HANDED, WHICH IS AN ORDERING
|
||||
# CLAIM. `check_meter_frozen()` takes `self.target` - the arbiter's RESOLVED
|
||||
# INTENT - and `_shadow_settle()` re-seeds that to 0 W at the very end of the
|
||||
@@ -1807,15 +1865,15 @@ check("the status page has a Shadow mode row in BOTH states, so its ABSENCE is "
|
||||
_ROW in _shad_rows and _ROW in _live_rows)
|
||||
check("AC 3: the banner states plainly that the battery is not being "
|
||||
"controlled",
|
||||
"SHADOW MODE" in _shad_pay["banner"]
|
||||
and "NOT being controlled" in _shad_pay["banner"])
|
||||
"Shadow mode" in _shad_pay["banner"]
|
||||
and "not controlled" in _shad_pay["banner"])
|
||||
check("...and it is not green. A page that reads `ok` while nothing is being "
|
||||
"commanded is the 'looks healthy but is inert' failure itself",
|
||||
_shad_pay["level"] == "warn")
|
||||
check("...and it is FIRST in the cascade: the same controller has other "
|
||||
"conditions to report and none of them displaces this sentence",
|
||||
_live_pay["banner"] != _shad_pay["banner"]
|
||||
and "SHADOW MODE" not in _live_pay["banner"])
|
||||
and "Shadow mode" not in _live_pay["banner"])
|
||||
_slot = re.search(r"WOULD HAVE COMMANDED ([-+][\d ]+) W, inverter held at "
|
||||
r"([-\d]+) W", _shad_rows[_ROW])
|
||||
check("the row answers 'what would it have done' with a NUMBER in its own "
|
||||
@@ -1841,22 +1899,26 @@ check("with shadow mode off the row says so, and says what follows from it - "
|
||||
and "DOES reach the inverter" in _live_rows[_ROW]
|
||||
and "WOULD HAVE COMMANDED" not in _live_rows[_ROW])
|
||||
|
||||
# ⚠️ A STANDING LATCH IS NAMED RATHER THAN HIDDEN. The shadow banner sits above
|
||||
# the three `bad` branches, so it has to carry what they would have said - a
|
||||
# ⚠️ A STANDING LATCH IS SHOWN RATHER THAN HIDDEN. The shadow banner sits above
|
||||
# the three `bad` branches, so it has to say what they would have said - a
|
||||
# latch that is up while the controller is inert is up the moment it stops
|
||||
# being inert.
|
||||
# being inert. UX-09: the banner (12 words) says a safety stop outlasts shadow
|
||||
# mode, and the latch's own red row, still on the list, names it.
|
||||
_shad_c.inverters[0].sign_wd.tripped = True
|
||||
_latched = _shad_c.status_payload()
|
||||
print(f" banner with a latch up: {_latched['banner']!r}")
|
||||
check("a failsafe latch that is standing is NAMED in the shadow banner and "
|
||||
"turns it red, so nobody turns shadow mode off into a battery that will "
|
||||
"not move and a page that never mentioned why",
|
||||
check("a failsafe latch that is standing turns the shadow banner red and the "
|
||||
"banner says a safety stop stays on, so nobody turns shadow mode off "
|
||||
"into a battery that will not move and a page that never mentioned why",
|
||||
_latched["level"] == "bad"
|
||||
and "LATCH IS STILL UP" in _latched["banner"]
|
||||
and _shad_c.inverters[0].name in _latched["banner"])
|
||||
and "safety stop stays on" in _latched["banner"])
|
||||
check("...and the latch is NAMED on its own red row, which says how it clears",
|
||||
any(not r["ok"] and not r["warn"] and r.get("id") == "direction"
|
||||
and "A restart does not clear this" in r["text"]
|
||||
for r in _shad_c.checks()))
|
||||
check("...and it still says the battery is not being controlled, so the latch "
|
||||
"has not displaced the sentence that may never be displaced",
|
||||
"NOT being controlled" in _latched["banner"])
|
||||
"not controlled" in _latched["banner"])
|
||||
_shad_c.inverters[0].sign_wd.tripped = False
|
||||
|
||||
# --- 8i. THE RECORD A LATER ANALYSIS READS ----------------------------------
|
||||
@@ -1991,8 +2053,8 @@ check("...logged as a WARNING, not an ERROR",
|
||||
and not any(x.levelno >= logging.ERROR and "OUTPUT_CLAMP" in x.getMessage()
|
||||
for x in log_i))
|
||||
check("...and the status row is amber, not red",
|
||||
any(c["warn"] and "LOOP AT INTEGRATOR BOUND" in c["text"] for c in red_i)
|
||||
and not any(not c["warn"] and "OUTPUT CLAMP ENGAGED" in c["text"]
|
||||
any(c["warn"] and c.get("id") == "not_keeping_up" for c in red_i)
|
||||
and not any(not c["warn"] and c.get("id") == "power_too_high"
|
||||
for c in red_i))
|
||||
|
||||
# --- 9b. the genuine over-rating: integrator_max_w above max_w ----------------
|
||||
@@ -2023,8 +2085,17 @@ check("...under the over-rating title, quoting a tick's own asked and sent "
|
||||
and any(_asked_then_sent(n["message"], _f(d, 'requested_w'),
|
||||
_f(d, 'clamped_w')) for d, t, r in over)
|
||||
for n in clamp_notes(hass_o))
|
||||
and any(not c["warn"] and "OUTPUT CLAMP ENGAGED" in c["text"]
|
||||
and any(not c["warn"] and c.get("id") == "power_too_high"
|
||||
and c["text"].startswith(messages.T_OUTPUT_CLAMP)
|
||||
for c in red_o))
|
||||
# The red row quotes the same tick's numbers as the card, asked before sent.
|
||||
_row_o = [c["text"] for c in red_o if c.get("id") == "power_too_high"]
|
||||
check("...and the red row quotes asked before sent, from one of those ticks",
|
||||
_row_o and any(
|
||||
f"asked {messages.watts(_f(d, 'requested_w'))}" in _row_o[0]
|
||||
and f"sent {messages.watts(_f(d, 'clamped_w'))}" in _row_o[0]
|
||||
and _row_o[0].index("asked") < _row_o[0].index("sent")
|
||||
for d, t, r in over))
|
||||
|
||||
# --- 9c. the text, directly, and the two budgets -------------------------------
|
||||
from app.clamp import loop_clamp_note # noqa: E402
|
||||
|
||||
@@ -337,15 +337,19 @@ def rows_for(pass_age):
|
||||
|
||||
r_new, r_29, r_31 = rows_for(None), rows_for(29), rows_for(31)
|
||||
print(f" {r_new[0]} | {r_29[0]} | {r_31[0]}")
|
||||
# UX-08: the wording is app/messages.py's; these pin the meaning - which row,
|
||||
# its colour, and the two numbers (age, veto) an operator acts on.
|
||||
check("before the first pass the row is ok and says 'starting'",
|
||||
r_new[0] == {"ok": True, "warn": False, "text": "control loop: starting"})
|
||||
r_new[0]["id"] == "controller" and r_new[0]["ok"] and not r_new[0]["warn"]
|
||||
and "starting" in r_new[0]["text"])
|
||||
check("29 s after a pass it is ok",
|
||||
r_29[0] == {"ok": True, "warn": False,
|
||||
"text": "control loop: last pass 29 s ago"})
|
||||
r_29[0]["id"] == "controller" and r_29[0]["ok"] and not r_29[0]["warn"]
|
||||
and "29 seconds ago" in r_29[0]["text"])
|
||||
check("31 s after a pass it is RED and first, naming the age and the veto",
|
||||
r_31[0] == {"ok": False, "warn": False,
|
||||
"text": "control loop: NO PASS FOR 31 s (layer 1 zeroes the "
|
||||
"inverter after 30 s without a heartbeat)"})
|
||||
r_31[0]["id"] == "controller" and not r_31[0]["ok"]
|
||||
and not r_31[0]["warn"]
|
||||
and "not run for 31 seconds" in r_31[0]["text"]
|
||||
and "0 W after 30 seconds" in r_31[0]["text"])
|
||||
|
||||
|
||||
async def one_pass():
|
||||
|
||||
@@ -930,14 +930,18 @@ check("...but the banner does NOT go on saying 'Running - holding grid at "
|
||||
"zero'. That sentence is a claim the site cannot make while a unit is "
|
||||
"absent, and 'the page reads healthy while the fault runs' is the shape "
|
||||
"this whole card exists to remove. It names the unit and stays a WARNING",
|
||||
_pay["level"] == "warn" and "NOT DELIVERING" in _pay["banner"]
|
||||
_pay["level"] == "warn" and "is not delivering" in _pay["banner"]
|
||||
and "inverter-b" in _pay["banner"]
|
||||
and "holding grid at zero" not in _pay["banner"])
|
||||
print(f" banner: {_pay['level']!r} / {_pay['banner']!r}")
|
||||
_row = [r for r in _cw.checks() if "NOT DELIVERING" in r["text"]]
|
||||
_row = [r for r in _cw.checks()
|
||||
if r.get("id") == "delivery" and "not delivering" in r["text"]]
|
||||
check("the status page carries it as a CAUTION, not a failure: the site is "
|
||||
"still running and short, which a red cross would misdescribe",
|
||||
len(_row) == 1 and _row[0]["ok"] is False and _row[0]["warn"] is True)
|
||||
len(_row) == 1 and _row[0]["ok"] is False and _row[0]["warn"] is True
|
||||
and "inverter-b" in _row[0]["text"])
|
||||
check("...and the row says how it clears: a stop and start of control",
|
||||
bool(_row) and "stopping and starting control" in _row[0]["text"])
|
||||
|
||||
|
||||
# ===========================================================================
|
||||
@@ -1173,10 +1177,11 @@ check("...and no store key was written, so a one-inverter install's state file "
|
||||
"is byte-identical to what it was before this card",
|
||||
unit_key(_only.name, "delivery_tripped") not in _st1.data
|
||||
and unit_key(_only.name, "delivery_reason") not in _st1.data)
|
||||
_n1row = [r for r in _c1.checks() if "delivery watchdog" in r["text"]]
|
||||
_n1row = [r for r in _c1.checks() if r.get("id") == "delivery"]
|
||||
check("...and the status page says n/a rather than 'armed', which would be a "
|
||||
"claim to be watching something that cannot happen",
|
||||
len(_n1row) == 1 and _n1row[0]["ok"] and "n/a at one inverter" in _n1row[0]["text"])
|
||||
len(_n1row) == 1 and _n1row[0]["ok"]
|
||||
and "not needed with one inverter" in _n1row[0]["text"])
|
||||
check("...no persistent notification of this kind was raised either",
|
||||
not [c for c in _h1.calls
|
||||
if "not_delivering" in str(c[2].get("notification_id", ""))])
|
||||
|
||||
@@ -832,7 +832,7 @@ all_notes = all_notes_of(hass_f) # the whole surface
|
||||
# install has. Flipped here rather than plumbing a whole P1 transport in - the
|
||||
# row's own content is what is under test.
|
||||
ctl_f.p1_enabled = True
|
||||
frozen_rows = [c for c in ctl_f.checks() if "METER MAY BE FROZEN" in c["text"]]
|
||||
frozen_rows = [c for c in ctl_f.checks() if c.get("id") == "meter_frozen"]
|
||||
print(f" frozen at +4000 W: command ran to {ctl_f.target:.0f} W, "
|
||||
f"{len(notes)} notification(s), {len(frozen_rows)} red status row(s)")
|
||||
# SURFACE-WIDE, deliberately, and the second guard has now landed. SAFETY-03
|
||||
@@ -862,6 +862,9 @@ check("...and it says the controller is still running",
|
||||
bool(notes) and "Control is still running" in notes[0]["message"])
|
||||
check("the status page carries a failed row saying so",
|
||||
len(frozen_rows) == 1 and not frozen_rows[0]["ok"] and not frozen_rows[0]["warn"])
|
||||
check("...and the row says control still follows the reading and what to do",
|
||||
bool(frozen_rows) and "still follows it" in frozen_rows[0]["text"]
|
||||
and "Check the meter" in frozen_rows[0]["text"])
|
||||
check("the event log names it", any("METER FROZEN" in e for e in ctl_f.events))
|
||||
# ⚠️ NOTIFY, NOT TRIP. If a later cut turns this into a trip it must come here
|
||||
# and change this expectation deliberately, not discover it in the field.
|
||||
@@ -1106,8 +1109,7 @@ def freeze_rows(unchanged_s, grid, **over):
|
||||
# p1_enabled is what a homewizard_local install has; the row's own content
|
||||
# is what is under test, not the transport that feeds it.
|
||||
ctl.p1_enabled = True
|
||||
return ctl, [r for r in ctl.checks()
|
||||
if r["text"].startswith("freeze detector")]
|
||||
return ctl, [r for r in ctl.checks() if r.get("id") == "freeze_check"]
|
||||
|
||||
|
||||
_ctl_u, _rows_u = freeze_rows(None, 4000.0, meter_source="ha_dsmr")
|
||||
@@ -1116,30 +1118,31 @@ print(f" uncovered: {_rows_u[0]['text'] if _rows_u else '(no row at all)'}")
|
||||
print(f" covered: {_rows_c[0]['text'] if _rows_c else '(no row at all)'}")
|
||||
check("an uncovered transport gets exactly one freeze-detector row",
|
||||
len(_rows_u) == 1)
|
||||
check("...and it says NOT COVERED",
|
||||
bool(_rows_u) and "NOT COVERED" in _rows_u[0]["text"])
|
||||
# UX-08: the row says the check is off and which source it needs, in words
|
||||
# (STYLE.md: no option values). DOCS.md "Status page" maps them to the keys.
|
||||
check("...and it says the check is off",
|
||||
bool(_rows_u) and ": off" in _rows_u[0]["text"])
|
||||
check("...and it does NOT claim the guard is armed - that would be the status "
|
||||
"page lying on behalf of a guard that cannot run",
|
||||
bool(_rows_u) and "armed" not in _rows_u[0]["text"])
|
||||
check("...and it names the meter_source it is not covering, so the operator "
|
||||
"knows which install this is",
|
||||
bool(_rows_u) and "ha_dsmr" in _rows_u[0]["text"])
|
||||
check("...and it names homewizard_local as the transport that would be covered",
|
||||
bool(_rows_u) and "homewizard_local" in _rows_u[0]["text"])
|
||||
bool(_rows_u) and "alerts after" not in _rows_u[0]["text"])
|
||||
check("...and it names HomeWizard local as the source that would be covered",
|
||||
bool(_rows_u) and "HomeWizard local" in _rows_u[0]["text"])
|
||||
check("...flagged as a warning rather than a silent ok",
|
||||
bool(_rows_u) and not _rows_u[0]["ok"] and _rows_u[0]["warn"])
|
||||
|
||||
check("a COVERED transport gets exactly one freeze-detector row",
|
||||
len(_rows_c) == 1)
|
||||
check("...and that one DOES say armed - without this, 'the uncovered row does "
|
||||
"not say armed' is satisfied by deleting the armed branch",
|
||||
bool(_rows_c) and "armed" in _rows_c[0]["text"]
|
||||
and "NOT COVERED" not in _rows_c[0]["text"])
|
||||
check("...and that one DOES say it is on - without this, 'the uncovered row "
|
||||
"does not say armed' is satisfied by deleting the armed branch",
|
||||
bool(_rows_c) and "alerts after" in _rows_c[0]["text"]
|
||||
and ": off" not in _rows_c[0]["text"])
|
||||
check("...and it quotes the hold and the rail it is armed at, derived from the "
|
||||
"config the controller was actually built with",
|
||||
bool(_rows_c)
|
||||
and f"{_ctl_c.freeze_wd.cfg.hold_s:.0f} s unchanged" in _rows_c[0]["text"]
|
||||
and f"{rail_w(LIVE_INSTALL_MAX_W):.0f} W" in _rows_c[0]["text"])
|
||||
and f"{messages.duration(_ctl_c.freeze_wd.cfg.hold_s)} unchanged"
|
||||
in _rows_c[0]["text"]
|
||||
and f"above {messages.watts(rail_w(LIVE_INSTALL_MAX_W))}"
|
||||
in _rows_c[0]["text"])
|
||||
check("...as an ok row, since a covered armed guard is not a warning",
|
||||
bool(_rows_c) and _rows_c[0]["ok"] and not _rows_c[0]["warn"])
|
||||
|
||||
@@ -1196,7 +1199,8 @@ check("...and the notification the operator gets names no max_w rail, and the "
|
||||
_c20.p1_enabled = True
|
||||
check("...and the red status row is up too, so the page and the notification "
|
||||
"agree",
|
||||
any("METER MAY BE FROZEN" in r["text"] for r in _c20.checks()))
|
||||
any(r.get("id") == "meter_frozen" and not r["ok"] and not r["warn"]
|
||||
for r in _c20.checks()))
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
@@ -1222,23 +1226,25 @@ check("a device smaller than max_w still gets exactly one freeze-detector row",
|
||||
check("...and the page does NOT print the max_w rail the command can never "
|
||||
"reach - THE DEFECT, in one assertion",
|
||||
bool(_rows_s)
|
||||
and f"{rail_w(LIVE_INSTALL_MAX_W):.0f} W" not in _rows_s[0]["text"])
|
||||
and messages.watts(rail_w(LIVE_INSTALL_MAX_W)) not in _rows_s[0]["text"])
|
||||
check("...it prints the rail the predicate actually uses",
|
||||
bool(_rows_s)
|
||||
and f"{rail_w(LIVE_INSTALL_MAX_W, dev_min=-4700.0, dev_max=4700.0):.0f} W"
|
||||
in _rows_s[0]["text"])
|
||||
check("...and it names the device range as the reason, since the operator "
|
||||
"configured max_w and is owed the reason the guard is armed elsewhere",
|
||||
bool(_rows_s) and "4700" in _rows_s[0]["text"]
|
||||
and "max_w" in _rows_s[0]["text"])
|
||||
and messages.watts(rail_w(LIVE_INSTALL_MAX_W, dev_min=-4700.0,
|
||||
dev_max=4700.0)) in _rows_s[0]["text"])
|
||||
check("...and it names the inverter's own limit as the reason, since the "
|
||||
"operator configured max_w and is owed the reason the guard is armed "
|
||||
"elsewhere",
|
||||
bool(_rows_s) and "the inverter's own limit" in _rows_s[0]["text"])
|
||||
check("...and it does not say so when max_w itself sets the rail",
|
||||
bool(_rows_c) and "own limit" not in _rows_c[0]["text"])
|
||||
|
||||
# ⚠️ THE NUMBER IS TAKEN OFF THE ROW AND FED BACK INTO THE SHIPPED PREDICATE.
|
||||
# Asserting the page against `rail_w(...)` alone proves the two agree, which a
|
||||
# revert of BOTH to bare max_w also satisfies. What a revert cannot satisfy is
|
||||
# this: the rail the page advertises has to be a magnitude the wire can carry,
|
||||
# and the wire stops at the device rating.
|
||||
_m = re.search(r"command is over (\d+(?:\.\d+)?) W", _rows_s[0]["text"]) if _rows_s else None
|
||||
_page_rail = float(_m.group(1)) if _m else None
|
||||
_m = re.search(r"above (\d[\d ]*) W", _rows_s[0]["text"]) if _rows_s else None
|
||||
_page_rail = float(_m.group(1).replace(" ", "")) if _m else None
|
||||
print(f" the page advertises a rail of {_page_rail} W against a device that "
|
||||
f"stops at {_ctl_s.dev_max:.0f} W")
|
||||
check("...the row states a rail in watts at all, so the parse below means "
|
||||
@@ -1256,11 +1262,13 @@ check("...as an ok row - a guard armed at a lower rail is still armed, not a "
|
||||
"warning", bool(_rows_s) and _rows_s[0]["ok"] and not _rows_s[0]["warn"])
|
||||
|
||||
check("a device with no commandable range gets exactly one row", len(_rows_z) == 1)
|
||||
check("...and it says NOT COVERED - the rail is not merely low there, it is "
|
||||
"0 W, which would be TRUE of every command including a parked one",
|
||||
bool(_rows_z) and "NOT COVERED" in _rows_z[0]["text"])
|
||||
check("...and it NEVER says armed",
|
||||
bool(_rows_z) and "armed" not in _rows_z[0]["text"])
|
||||
check("...and it says the check is off for the power range - the rail is not "
|
||||
"merely low there, it is 0 W, which would be TRUE of every command "
|
||||
"including a parked one",
|
||||
bool(_rows_z) and ": off" in _rows_z[0]["text"]
|
||||
and "power range" in _rows_z[0]["text"])
|
||||
check("...and it NEVER says armed",
|
||||
bool(_rows_z) and "alerts after" not in _rows_z[0]["text"])
|
||||
check("...flagged as a warning rather than a silent ok, like the uncovered "
|
||||
"transport row it shares",
|
||||
bool(_rows_z) and not _rows_z[0]["ok"] and _rows_z[0]["warn"])
|
||||
|
||||
@@ -69,6 +69,7 @@ from datetime import datetime, timezone
|
||||
from pathlib import Path
|
||||
|
||||
from app import freshness as F
|
||||
from app import messages
|
||||
from named_absence import first, given, nth, present
|
||||
from app.circulation import circulating_w
|
||||
from app.freshness import BOUNDS, BATT_OBLIGED_S, BATT_UNCHANGED_S, MOVE_W, Freshness
|
||||
@@ -1823,7 +1824,8 @@ def _s56_row(c):
|
||||
a red with no name attached, which reads like broken infrastructure and gets
|
||||
retried rather than read. Measured: 0 named reds before, 2 after.
|
||||
"""
|
||||
hits = [r for r in c.checks() if r["text"].startswith("battery power")]
|
||||
hits = [r for r in c.checks() if r.get("id") == "sensor"
|
||||
and r["text"].startswith(messages.LABEL_BATTERY)]
|
||||
if len(hits) == 1:
|
||||
return hits[0]
|
||||
return {"ok": None, "warn": None,
|
||||
@@ -1933,14 +1935,17 @@ check("⚠️ AND THE VERDICT IS UNCHANGED BY THIS CARD - both rows are still "
|
||||
_row56_ref["ok"] is False and _row56_ref["warn"] is False
|
||||
and _row56_abs["ok"] is False and _row56_abs["warn"] is False
|
||||
and _row56_ref["text"] == _row56_abs["text"])
|
||||
check("...and what it says instead is the observation plus BOTH causes, with "
|
||||
f"{_BATT_ENT} in its own slot - `label` and `entity` are two "
|
||||
f"interpolations in one sentence and swapping them costs zero bytes, so "
|
||||
f"the literal around each is pinned (habit 14)",
|
||||
f"battery power: no usable value this cycle from {_BATT_ENT} - and this "
|
||||
f"row cannot tell which of two things that is" in _row56_ref["text"]
|
||||
and "the entity is missing or not numeric" in _row56_ref["text"]
|
||||
and "a number that this controller is withholding" in _row56_ref["text"])
|
||||
# UX-08: the row names the setting by its label, never the entity id
|
||||
# (STYLE.md), so there is no second interpolation left to transpose.
|
||||
check("...and what it says instead is the observation plus BOTH causes, under "
|
||||
"its own label, and the check to make before replacing the sensor - with "
|
||||
f"no entity id ({_BATT_ENT}) on the page row",
|
||||
_row56_ref["text"].startswith(f"{messages.LABEL_BATTERY}: no usable "
|
||||
f"reading")
|
||||
and "may be missing" in _row56_ref["text"]
|
||||
and "held back as too old" in _row56_ref["text"]
|
||||
and "Developer Tools before replacing it" in _row56_ref["text"]
|
||||
and _BATT_ENT not in _row56_ref["text"])
|
||||
check("⚠️ AND THE DISCRIMINATOR IT POINTS AT EXISTS AND IS SELECTIVE, which is "
|
||||
"why the row does not need to ask `batt_fresh.stale` itself: `checks()` "
|
||||
"carries a STALE_READING row in REFUSED and NONE in ABSENT, so 'is that "
|
||||
@@ -1957,7 +1962,7 @@ check("...and the row's wording is NOT shared with the log line's, which is a "
|
||||
"other caller does not need",
|
||||
_S56_EXPLANATIONS[0][1] not in _row56_ref["text"]
|
||||
and _S56_EXPLANATIONS[1][1] not in _row56_ref["text"]
|
||||
and "no usable value this cycle" not in _r56_ref)
|
||||
and "no usable reading" not in _r56_ref)
|
||||
|
||||
# --- 11e. what part 11 does NOT grade, with its shape (habit 13) -------------
|
||||
# * It does not show the live episode was a BMS refusal beyond doubt. 11a
|
||||
|
||||
@@ -811,9 +811,11 @@ check("...and the status page shows BOTH per-inverter rows - one latched, one "
|
||||
"'the sign watchdog is armed' printed over a latched sibling is the page "
|
||||
"lying",
|
||||
len([r for r in _c3r.checks()
|
||||
if r["text"].startswith("sign watchdog [")]) == 1
|
||||
if r.get("id") == "direction" and r["ok"]
|
||||
and "inverter-a" in r["text"]]) == 1
|
||||
and len([r for r in _c3r.checks()
|
||||
if "SIGN-DISAGREEMENT FAILSAFE [" in r["text"]]) == 1)
|
||||
if r.get("id") == "direction" and not r["ok"]
|
||||
and not r["warn"] and "inverter-b" in r["text"]]) == 1)
|
||||
check("⚠️ AND SAFETY-30's SITE ROW IS THERE BESIDE THEM, EXACTLY ONCE. At two "
|
||||
"inverters there are three sign questions on this page and they are three "
|
||||
"rows: is A doing what it was told, is B, and is the SITE'S TOTAL "
|
||||
@@ -823,15 +825,15 @@ check("⚠️ AND SAFETY-30's SITE ROW IS THERE BESIDE THEM, EXACTLY ONCE. At tw
|
||||
"per-unit rows would be advertising two guards where the install has "
|
||||
"three",
|
||||
len([r for r in _c3r.checks()
|
||||
if r["text"].startswith("site sign watchdog:")]) == 1)
|
||||
if r.get("id") == "site_direction"]) == 1)
|
||||
check("...and the per-inverter rows now say WHAT the unit was compared "
|
||||
"against, because at a roster of two it is no longer the meter. A row "
|
||||
"still reading 'the command opposed the meter' would send an operator to "
|
||||
"look at P1 for a fault that is visible only on one inverter's own power "
|
||||
"sensor",
|
||||
all("its own measured power" in r["text"] for r in _c3r.checks()
|
||||
if r["text"].startswith(("sign watchdog [",
|
||||
"SIGN-DISAGREEMENT FAILSAFE ["))))
|
||||
len([r for r in _c3r.checks() if r.get("id") == "direction"]) == 2
|
||||
and all("its own power" in r["text"] for r in _c3r.checks()
|
||||
if r.get("id") == "direction"))
|
||||
|
||||
# The operator's clear, which is one button and has to reach every latch.
|
||||
run(_c3r.handle_action("auto_toggle")) # -> stopped
|
||||
@@ -1354,7 +1356,7 @@ check("⚠️ AND A UNIT WITH NO `setpoint_entity` IS DELIBERATELY STILL LIVE HE
|
||||
inverter_b(setpoint="").is_live(_now)[0] is True)
|
||||
check("...and the status page says so in its own row, which is the surface an "
|
||||
"operator actually reads",
|
||||
any("NO SETPOINT ENTITY" in n for n in
|
||||
any("“Setpoint entity” is not set" in n for n in
|
||||
built(store=MemStore(), second=inverter_b(setpoint=""))[0]
|
||||
.liveness_notes()))
|
||||
check("...and a healthy site adds NO liveness rows at all, so the page is not "
|
||||
|
||||
@@ -7,8 +7,11 @@
|
||||
2. No notification is worded anywhere else. An AST scan of `app/` fails any
|
||||
`persistent_notification` call whose payload is not built by
|
||||
`app/messages.py`.
|
||||
3. THE RATCHET for the kinds not rewritten yet. Every status-row and banner
|
||||
literal, every validator refusal, every WARNING+ log line and every option
|
||||
3. The status page. Every row and banner in `app/messages.py` obeys the rule
|
||||
for its colour: a row one sentence of at most 15 words, a red row up to 3
|
||||
sentences and 30 words, a banner at most 12 words.
|
||||
THE RATCHET for the kinds not rewritten yet. Every status-row and banner
|
||||
literal left in `app/`, every validator refusal, every WARNING+ log line and every option
|
||||
name and description in `translations/en.yaml` must either obey its limit
|
||||
or appear in `ux08_allowlist.txt`. A new string that breaks the rule and is
|
||||
not listed goes red. So does a listed entry that no longer matches a
|
||||
@@ -147,15 +150,134 @@ check(f"the samples cover every notification id in the catalogue "
|
||||
check("the payload carries exactly the three keys Home Assistant accepts",
|
||||
all(set(n.data()) == {"notification_id", "title", "message"}
|
||||
for n in SAMPLES))
|
||||
# The Details link (UX-09). Home Assistant 2026.2+ serves add-on pages at
|
||||
# /config/app/<slug>/<tab> and 2026.5 dropped /hassio/addon/<slug>/<tab>, so
|
||||
# the path follows the version the Supervisor reports; unknown means current.
|
||||
_LINE = ("Details: [add-on documentation](/config/app/local_goodwe_controller/"
|
||||
"documentation), section “Battery is not keeping up” under "
|
||||
"Notifications.")
|
||||
os.environ["HOSTNAME"] = "3f2a9c1b7d4e" # a container id, as on TEST-23
|
||||
messages.set_site("local_goodwe_controller", "2026.9.1")
|
||||
check("with the Supervisor's slug the Details line is exactly the current-HA "
|
||||
"link plus the section by name, even when the hostname is a container id",
|
||||
SAMPLES[0].data()["message"].endswith("\n\n" + _LINE))
|
||||
_link = {v: messages.docs_url("local_goodwe_controller", v)
|
||||
for v in ("2026.1.3", "2026.2.0", "2026.4.2", "2026.10.0b1",
|
||||
"2025.12.5", None, "rubbish")}
|
||||
check(f"Home Assistant 2026.1 and older get the old /hassio path, 2026.2 and "
|
||||
f"newer and an unknown version the /config/app path ({_link})",
|
||||
_link == {
|
||||
"2026.1.3": "/hassio/addon/local_goodwe_controller/documentation",
|
||||
"2025.12.5": "/hassio/addon/local_goodwe_controller/documentation",
|
||||
"2026.2.0": "/config/app/local_goodwe_controller/documentation",
|
||||
"2026.4.2": "/config/app/local_goodwe_controller/documentation",
|
||||
"2026.10.0b1": "/config/app/local_goodwe_controller/documentation",
|
||||
None: "/config/app/local_goodwe_controller/documentation",
|
||||
"rubbish": "/config/app/local_goodwe_controller/documentation"})
|
||||
messages.set_site("../../etc", "2026.9.1")
|
||||
check("a slug that is not this add-on's shape is not put in a link",
|
||||
"](" not in SAMPLES[0].data()["message"])
|
||||
messages.set_site(None, None)
|
||||
os.environ["HOSTNAME"] = "abcd1234-goodwe-controller"
|
||||
check("inside the add-on the Details line links to its documentation page",
|
||||
"(/hassio/addon/abcd1234_goodwe_controller/documentation)"
|
||||
check("without the Supervisor's answer the slug comes from a Supervisor-style "
|
||||
"hostname",
|
||||
"(/config/app/abcd1234_goodwe_controller/documentation)"
|
||||
in SAMPLES[0].data()["message"])
|
||||
os.environ["HOSTNAME"] = "some-laptop"
|
||||
check("...and anywhere else it names the section without a guessed link",
|
||||
"](" not in SAMPLES[0].data()["message"]
|
||||
and "under Notifications" in SAMPLES[0].data()["message"])
|
||||
SAMPLES[0].data()["message"].endswith(
|
||||
"\n\nDetails: add-on documentation, section “Battery is not keeping "
|
||||
"up” under Notifications."))
|
||||
del os.environ["HOSTNAME"]
|
||||
|
||||
# Where the slug and the version come from: the Supervisor, read once at start.
|
||||
import asyncio # noqa: E402
|
||||
from app.main import docs_link_facts # noqa: E402
|
||||
|
||||
|
||||
class _Resp:
|
||||
def __init__(self, body):
|
||||
self.body = body
|
||||
|
||||
async def __aenter__(self):
|
||||
if isinstance(self.body, Exception):
|
||||
raise self.body
|
||||
return self
|
||||
|
||||
async def __aexit__(self, *a):
|
||||
return False
|
||||
|
||||
async def json(self, content_type=None):
|
||||
return self.body
|
||||
|
||||
|
||||
class _Session:
|
||||
def __init__(self, answers):
|
||||
self.answers, self.asked, self.timeouts = answers, [], []
|
||||
|
||||
def get(self, url, **kw):
|
||||
self.asked.append((url, kw.get("headers", {}).get("Authorization")))
|
||||
self.timeouts.append(kw.get("timeout"))
|
||||
return _Resp(self.answers[url])
|
||||
|
||||
|
||||
_ok = _Session({
|
||||
"http://supervisor/addons/self/info": {"result": "ok", "data": {
|
||||
"slug": "local_goodwe_controller", "version": "0.12.0"}},
|
||||
"http://supervisor/info": {"result": "ok", "data": {
|
||||
"homeassistant": "2026.9.1", "supervisor": "2026.08.0"}}})
|
||||
_down = _Session({"http://supervisor/addons/self/info": OSError("refused"),
|
||||
"http://supervisor/info": ValueError("not json")})
|
||||
check("at start the add-on asks the Supervisor for its slug and HA's version, "
|
||||
"with its own token",
|
||||
asyncio.run(docs_link_facts(_ok, "tok")) == {
|
||||
"slug": "local_goodwe_controller", "ha_version": "2026.9.1"}
|
||||
and all(a == "Bearer tok" for _u, a in _ok.asked))
|
||||
check("...and a Supervisor that does not answer costs the link, never the "
|
||||
"start",
|
||||
asyncio.run(docs_link_facts(_down, "tok")) == {
|
||||
"slug": None, "ha_version": None})
|
||||
check("...and each question has a short timeout, so a Supervisor that hangs "
|
||||
f"delays control start by seconds, not minutes ({_ok.timeouts})",
|
||||
len(_ok.timeouts) == 2
|
||||
and all(isinstance(t, (int, float)) and 0 < t <= 3 for t in _ok.timeouts))
|
||||
|
||||
# Shadow mode (UX-09): nothing the add-on decides reaches the inverter, so no
|
||||
# text may say a command was sent or that the battery is giving power.
|
||||
_c1 = [messages.Clamp(None, 7412, 5000, "rating")]
|
||||
_c2 = [messages.Clamp("inverter-a", -3000, -2500, "device"),
|
||||
messages.Clamp("inverter-b", 6000, 4600, "max_w+device")]
|
||||
_live = [messages.output_clamp(c).body for c in (_c1, _c2, ())]
|
||||
_shad = [messages.output_clamp(c, shadow=True).body for c in (_c1, _c2, ())]
|
||||
check("live, the over-rating alarm says what was sent and that control runs",
|
||||
" and sent 5 000 W" in _live[0] and " and sent 2 500 W" in _live[1]
|
||||
and all("Control is still running" in b or "control is still running"
|
||||
in b for b in _live))
|
||||
check("in shadow mode it says what would have been sent, and that the "
|
||||
"inverters stay at 0 W",
|
||||
"would have sent 5 000 W" in _shad[0]
|
||||
and "would have sent 2 500 W" in _shad[1]
|
||||
and "would have been cut back" in _shad[2]
|
||||
and all(" sent" not in b.replace("would have sent", "") for b in _shad)
|
||||
and all("0 W" in b and "hadow mode" in b for b in _shad))
|
||||
_row_live = messages.row_power_too_high(_c1, 3)
|
||||
_row_shad = messages.row_power_too_high(_c1, 3, shadow=True)
|
||||
check("the over-rating row says 'sent' live and 'would send' in shadow mode",
|
||||
"sent 5 000 W" in _row_live and "would" not in _row_live
|
||||
and "would send 5 000 W" in _row_shad and " sent" not in _row_shad
|
||||
and "shadow mode" in _row_shad)
|
||||
_sat = messages.peak_saturated(5000, shadow=True).body
|
||||
check("in shadow mode the peak alarm does not claim the battery is giving "
|
||||
"power, and keeps its action",
|
||||
"giving all it can" not in _sat and "gives nothing" in _sat
|
||||
and "Switch off large loads" in _sat
|
||||
and "giving all it can" in messages.peak_saturated(5000).body)
|
||||
check("shadow mode changes no notification's id or severity",
|
||||
all(messages.output_clamp(c, shadow=True).id == messages.ID_OUTPUT_CLAMP
|
||||
and messages.output_clamp(c, shadow=True).severity == messages.ALARM
|
||||
for c in (_c1, _c2, ()))
|
||||
and messages.peak_saturated(1, shadow=True).id == messages.ID_PEAK_SATURATED
|
||||
and messages.peak_saturated(1, shadow=True).severity == messages.ALARM)
|
||||
check("the output-clamp alarm quotes asked before sent",
|
||||
messages.output_clamp([messages.Clamp(None, 7412, 5000, "rating")]).body
|
||||
.index("7 412 W") < messages.output_clamp(
|
||||
@@ -302,7 +424,7 @@ ALLOW_FILE = HERE / "ux08_allowlist.txt"
|
||||
# The allowlist may never grow. The test demands the list be exactly this long,
|
||||
# so deleting lines means lowering this number in the same change, and adding
|
||||
# one means raising it where a reviewer sees it.
|
||||
ALLOWLIST_MAX = 200
|
||||
ALLOWLIST_MAX = 167
|
||||
|
||||
|
||||
def read_allowlist(path):
|
||||
@@ -326,10 +448,68 @@ if "--violations" in sys.argv:
|
||||
print(f"{k} # {where} {'; '.join(p)} :: {text[:70]!r}")
|
||||
sys.exit(0)
|
||||
|
||||
STATUS = messages.status_samples()
|
||||
|
||||
|
||||
def row_problems(colour, text):
|
||||
"""STYLE.md section 1 for a status row (by colour) or a banner (None)."""
|
||||
n_s, n_w = sentences(text), len(words(text))
|
||||
out = []
|
||||
if colour is None:
|
||||
if n_w > 12:
|
||||
out.append(f"banner over 12 words ({n_w})")
|
||||
elif colour == messages.RED:
|
||||
if n_s > 3:
|
||||
out.append(f"red row over 3 sentences ({n_s})")
|
||||
if n_w > 30:
|
||||
out.append(f"red row over 30 words ({n_w})")
|
||||
else:
|
||||
if n_s > 1:
|
||||
out.append(f"{colour} row over 1 sentence ({n_s})")
|
||||
if n_w > 15:
|
||||
out.append(f"{colour} row over 15 words ({n_w})")
|
||||
if ";" in text:
|
||||
out.append("semicolon: split it into sentences or drop a clause")
|
||||
return out + text_problems(text, keys=False, entities=False)
|
||||
|
||||
|
||||
for fn, colour, text in STATUS:
|
||||
p = row_problems(colour, text)
|
||||
check(f"{colour or 'banner':6} {text!r}{' - ' + '; '.join(p) if p else ''}",
|
||||
not p)
|
||||
_catalogue = {k for k, v in vars(messages).items()
|
||||
if callable(v) and k.startswith(("row_", "banner_"))}
|
||||
_missing = sorted(_catalogue - {fn for fn, _c, _t in STATUS})
|
||||
check(f"the samples cover every row and banner in the catalogue "
|
||||
f"(missing: {_missing})", not _missing)
|
||||
# A red row with no banner of its own heads the page as "Not ready - <its first
|
||||
# sentence>". The three trips have their own branch in status_payload(), and
|
||||
# main.py gives the other two a "banner" key (both are sampled above).
|
||||
_own_banner = {"row_direction_trip", "row_site_direction_trip",
|
||||
"row_circulating_trip", "row_peak_reserve", "row_power_too_high"}
|
||||
_long = [t for fn, c, t in STATUS if c == messages.RED and fn not in _own_banner
|
||||
and len(words(messages.banner_not_ready({"text": t}))) > 12]
|
||||
check(f"every other red row makes a 'Not ready' banner of at most 12 words "
|
||||
f"(too long: {_long})", not _long)
|
||||
|
||||
# A latch row must say how it clears: that is the one action it exists for.
|
||||
_clears = {
|
||||
"row_direction_trip": "A restart does not clear this",
|
||||
"row_site_direction_trip": "Only starting control clears this",
|
||||
"row_circulating_trip": "Only starting control clears this",
|
||||
"row_not_delivering": "only stopping and starting control clears this",
|
||||
}
|
||||
_unclear = [fn for fn, _c, t in STATUS if fn in _clears and _clears[fn] not in t]
|
||||
check(f"every latch row says how it clears (missing: {_unclear})",
|
||||
not _unclear and {fn for fn, _c, _t in STATUS} >= set(_clears))
|
||||
|
||||
allow = read_allowlist(ALLOW_FILE)
|
||||
by_kind = {}
|
||||
for kind, *_ in found:
|
||||
by_kind[kind] = by_kind.get(kind, 0) + 1
|
||||
for _fn, colour, _t in STATUS:
|
||||
kind = "row" if colour else "banner"
|
||||
by_kind[kind] = by_kind.get(kind, 0) + 1
|
||||
check(f"the scan found every ratcheted kind ({by_kind})",
|
||||
all(by_kind.get(k, 0) >= 5 for k in LIMITS))
|
||||
new = sorted(k for k in violating if k not in allow)
|
||||
@@ -361,6 +541,8 @@ section = part[-1].split("\n## ", 1)[0] if len(part) == 2 else ""
|
||||
heads = set(re.findall(r"^### (.+)$", section, re.M))
|
||||
missing = sorted({n.docs for n in SAMPLES} - heads)
|
||||
check(f"...with a heading for every Details line (missing: {missing})", not missing)
|
||||
check("DOCS.md explains the status page rows under "
|
||||
f"'## {messages.DOCS_STATUS}'", f"\n## {messages.DOCS_STATUS}\n" in DOCS)
|
||||
|
||||
|
||||
# ============================================================================== #
|
||||
@@ -394,6 +576,18 @@ check("a message that lost its Details line is refused",
|
||||
_fake = " x = {'text': 'THE METER IS FROZEN AND NOTHING WORKS AT ALL'}\n"
|
||||
_n = [t for node in ast.walk(ast.parse(_fake.strip()))
|
||||
if isinstance(node, ast.Dict) for _, t in strings_in(node.values[0])]
|
||||
check("a second sentence in an amber row is refused",
|
||||
bool(row_problems(messages.AMBER, "Meter stuck. Check it.")))
|
||||
check("a fourth sentence in a red row is refused",
|
||||
bool(row_problems(messages.RED, "One. Two. Three. Four.")))
|
||||
check("a 16-word green row is refused",
|
||||
bool(row_problems(messages.GREEN, " ".join(["word"] * 16))))
|
||||
check("a 13-word banner is refused",
|
||||
bool(row_problems(None, " ".join(["word"] * 13))))
|
||||
check("an entity id in a status row is refused",
|
||||
bool(row_problems(messages.GREEN, "Battery level: sensor.soc = 54")))
|
||||
check("a semicolon in a status row is refused",
|
||||
bool(row_problems(messages.RED, "It stopped; check it.")))
|
||||
check("a new shouting status row is seen by the scan and is not listed",
|
||||
_n and problems_of("row", _n[0])
|
||||
and key_of("row", _n[0]) not in allow)
|
||||
|
||||
@@ -1432,7 +1432,7 @@ def p1_rows(ctl):
|
||||
a traceback instead of reddening the check that names the rule.
|
||||
"""
|
||||
try:
|
||||
return [c["text"] for c in ctl.checks() if c["text"].startswith("P1 meter")]
|
||||
return [c["text"] for c in ctl.checks() if c.get("id") == "meter"]
|
||||
except Exception as err: # noqa: BLE001 - a raise here is itself the failure
|
||||
print(f" checks() raised {type(err).__name__}: {err}")
|
||||
return err
|
||||
|
||||
@@ -1038,7 +1038,7 @@ check(f"a Controller built with peak_cap_w ABSENT takes the shipped "
|
||||
c.peak.cap_w == CAP_W)
|
||||
check("...and before the first cycle the guard has NO decision, which the "
|
||||
"status page must not spell as 'idle'", c.peak_guard is None)
|
||||
pre = [r for r in c.checks() if "peak guard" in r["text"]]
|
||||
pre = [r for r in c.checks() if r.get("id") == "peak_guard"]
|
||||
print(" status row before the first cycle: "
|
||||
+ (pre[0]["text"] if pre else "(none)"))
|
||||
check("the status page says so in its own row",
|
||||
@@ -1054,17 +1054,20 @@ c_off, hass_off = built(TMP / "legacy.db",
|
||||
{"meter_source": "off", "meter_entity": "sensor.grid"})
|
||||
c_off.auto, c_off.soc, c_off.batt, c_off.grid = True, 55.0, 0.0, -6000.0
|
||||
asyncio.get_event_loop_policy().new_event_loop().run_until_complete(c_off.cycle())
|
||||
off_rows = [r for r in c_off.checks() if "peak guard" in r["text"]]
|
||||
off_rows = [r for r in c_off.checks() if r.get("id") == "peak_guard"]
|
||||
print(f" meter_source off: guard={c_off.peak_guard}, wrote "
|
||||
f"{nth(hass_off.writes, -1):+.0f} W")
|
||||
print(" status row: " + (off_rows[0]["text"] if off_rows else "(none)"))
|
||||
check("with no P1 the guard does not run at all - it files nothing, and the "
|
||||
"legacy path can still charge", c_off.peak_guard is None
|
||||
and hass_off.writes and hass_off.writes[-1] < 0)
|
||||
check("...and the status page says NOT COVERED rather than 'idle' or a green "
|
||||
"row, which is the same answer SAFETY-18 already gives on a transport "
|
||||
"that cannot see it", len(off_rows) == 1
|
||||
and "NOT COVERED" in off_rows[0]["text"] and off_rows[0]["warn"])
|
||||
check("...and the status page says the guard is off, and why, rather than "
|
||||
"'idle' or a green row - the same answer SAFETY-18 already gives on a "
|
||||
"transport that cannot see it", len(off_rows) == 1
|
||||
and ": off" in off_rows[0]["text"]
|
||||
and "Where the meter reading comes from" in off_rows[0]["text"]
|
||||
and "idle" not in off_rows[0]["text"]
|
||||
and not off_rows[0]["ok"] and off_rows[0]["warn"])
|
||||
|
||||
# ⚠️ THE FIXTURE MUST LAND IN THE CURRENT QUARTER, AND THAT IS NOT PEDANTRY.
|
||||
# `cycle()` reads the real clock, and `project()` measures the open block against
|
||||
@@ -1214,7 +1217,7 @@ check("the real cycle files the peak claim and the real arbiter binds the real "
|
||||
and not c.peak_guard.saturated and "peak" in (c.reason or ""))
|
||||
check("...and the number written to the inverter is the guard's floor",
|
||||
hass.writes and near(hass.writes[-1], c.peak_guard.floor_w, 1.5))
|
||||
rows = [r for r in c.checks() if "peak guard" in r["text"].lower()]
|
||||
rows = [r for r in c.checks() if r.get("id") == "peak_guard"]
|
||||
print(" status row: " + (rows[0]["text"] if rows else "(none)"))
|
||||
check("the status page carries exactly one peak-guard row, flagged",
|
||||
len(rows) == 1 and rows[0]["warn"])
|
||||
@@ -1922,12 +1925,12 @@ asyncio.get_event_loop_policy().new_event_loop().run_until_complete(c24.cycle())
|
||||
check("...once per episode, not once per cycle - a quarter of an hour of "
|
||||
"identical cards is how an operator learns to dismiss the one that "
|
||||
"mattered", hass24.notifications.count("goodwe_peak_soc_floor") == 1)
|
||||
rows24 = [r for r in c24.checks() if "peak guard" in r["text"].lower()]
|
||||
rows24 = [r for r in c24.checks() if r.get("id") == "peak_guard"]
|
||||
print(" status row: " + (rows24[0]["text"] if rows24 else "(none)"))
|
||||
check("the status page carries exactly one peak-guard row and it is NOT ok - "
|
||||
"the money is going to be spent and a human is the only actuator left",
|
||||
len(rows24) == 1 and not rows24[0]["ok"]
|
||||
and "FLOOR-LIMITED" in rows24[0]["text"])
|
||||
len(rows24) == 1 and not rows24[0]["ok"] and not rows24[0]["warn"]
|
||||
and "peak limit will be passed" in rows24[0]["text"])
|
||||
check("...and it reaches the action log too", any("FLOOR-LIMITED" in e
|
||||
for e in c24.events))
|
||||
# A missing SoC sensor, through the same real cycle. `inputs_ok` stops the loop
|
||||
@@ -2479,17 +2482,23 @@ check("...and DOCS.md sends the reader to it rather than leaving the open "
|
||||
# comment is a scope sentence the operator never sees.
|
||||
c25, hass25, NET25, _ = wired_over_limit(
|
||||
TMP / "soc25.db", LIVE_MAX_W * 0.3, soc=SOC_FLOOR - 1.0)
|
||||
rows25 = [r for r in c25.checks() if "peak guard" in r["text"].lower()]
|
||||
rows25 = [r for r in c25.checks() if r.get("id") == "peak_guard"]
|
||||
|
||||
|
||||
def _row_scope(text):
|
||||
"""SAFETY-25 in messages.row_peak_reserve()'s words."""
|
||||
return ("Home use still draws the battery below it" in text
|
||||
and "down to the cut-out level" in text)
|
||||
|
||||
|
||||
print(" status row: " + (rows25[0]["text"] if rows25 else "(none)"))
|
||||
check("the STATUS PAGE row for a floor-limited guard says the floor bounds the "
|
||||
"guard only and that self-consumption may keep discharging below it. "
|
||||
"Without that sentence the page implies a pack-wide reserve at the exact "
|
||||
"moment the replay above says the loop is still emptying the pack",
|
||||
len(rows25) == 1
|
||||
and "PEAK GUARD FLOOR-LIMITED" in rows25[0]["text"]
|
||||
and "BOUNDS THE PEAK GUARD ONLY" in rows25[0]["text"].upper()
|
||||
and "not a pack-wide reserve" in rows25[0]["text"]
|
||||
and "BMS cut-out" in rows25[0]["text"])
|
||||
and "at its peak reserve" in rows25[0]["text"]
|
||||
and _row_scope(rows25[0]["text"]))
|
||||
# ⚠️ THE ROW KEEPS THE WHOLE SENTENCE; THE BANNER DOES NOT. status_payload()
|
||||
# renders the first not-ok/not-warn row as the page headline, so before this the
|
||||
# loudest element on the page was the same 550-character paragraph the row three
|
||||
@@ -2501,26 +2510,19 @@ print(f" banner ({len(_pay25['banner'])} chars): {_pay25['banner']}")
|
||||
# The guard's own line, which the banner has always carried and which is not
|
||||
# this card's to shorten: `explain()` is SAFETY-24's sentence about a quarter
|
||||
# that is going over the ceiling.
|
||||
_expl25 = nth(rows25, 0)["text"].split(". NOTE:")[0]
|
||||
check("the NOT READY banner is the guard's own line plus a SHORT scope tag - "
|
||||
"under 90 characters of it - and NOT the row's whole paragraph repeated "
|
||||
"at the top of the page. A headline that is a paragraph is a headline "
|
||||
"nobody reads, and this one is followed three lines later by the same "
|
||||
"text verbatim",
|
||||
present(_expl25)
|
||||
and _pay25["level"] == "bad"
|
||||
and _pay25["banner"].startswith("NOT READY")
|
||||
and _expl25 in _pay25["banner"]
|
||||
and "BOUNDS THE PEAK GUARD ONLY" in _pay25["banner"].upper()
|
||||
and "not a pack-wide reserve" not in _pay25["banner"]
|
||||
and len(_pay25["banner"]) - len(_expl25) < 90)
|
||||
check("...and shortening the banner did NOT shorten the row: the full AC 3 "
|
||||
# UX-08: the banner is the notification's own title, and the row below keeps
|
||||
# the SAFETY-25 sentence.
|
||||
check("the Not ready banner is a short headline - the notification's title - "
|
||||
"and NOT the row repeated at the top of the page. A headline that is a "
|
||||
"paragraph is a headline nobody reads",
|
||||
_pay25["level"] == "bad"
|
||||
and _pay25["banner"] == (f"{messages.NOT_READY} — "
|
||||
f"{messages.T_PEAK_RESERVE}")
|
||||
and not _row_scope(_pay25["banner"]))
|
||||
check("...and shortening the banner did NOT shorten the row: the SAFETY-25 "
|
||||
"sentence is still what the checks list carries, which is the surface the "
|
||||
"operator reads to find out what the floor does not bound",
|
||||
len(rows25) == 1
|
||||
and len(rows25[0]["text"]) > 300
|
||||
and "not a pack-wide reserve" in rows25[0]["text"]
|
||||
and "BMS cut-out" in rows25[0]["text"])
|
||||
"operator reads to find out what the reserve does not bound",
|
||||
len(rows25) == 1 and _row_scope(rows25[0]["text"]))
|
||||
|
||||
_body25 = hass25.last_message("goodwe_peak_soc_floor")
|
||||
|
||||
@@ -2529,8 +2531,8 @@ def _says_scope(body):
|
||||
"""SAFETY-25 in messages.peak_reserve()'s words: the reserve binds the peak
|
||||
guard only, and home use goes on discharging below it to the cut-out."""
|
||||
return ("The reserve only applies to keeping the peak down" in body
|
||||
and "normal home use can still discharge the battery below it" in body
|
||||
and "down to its cut-out level" in body)
|
||||
and "normal home use can still draw the battery below it" in body
|
||||
and "down to the battery cut-out level" in body)
|
||||
|
||||
|
||||
print(f" notification body tail: ...{_body25[-180:]}")
|
||||
@@ -5964,7 +5966,7 @@ check("...and the row still names WHERE the ceiling came from, which is the "
|
||||
# main.py:1951 is what the release edge writes.
|
||||
_c38, _h38 = built(TMP / "s38pin.db")
|
||||
_c38.peak_guard = _S38_IDLE
|
||||
_rows38 = [r for r in _c38.checks() if "peak guard" in r["text"]]
|
||||
_rows38 = [r for r in _c38.checks() if r.get("id") == "peak_guard"]
|
||||
print(" status row: " + (_rows38[0]["text"] if _rows38 else "(none)"))
|
||||
check("⚠️ ...AND THE SAME ORDERED PAIR ON THE STATUS PAGE (main.py:3313), read "
|
||||
"off the shipped `checks()` rather than off `explain()` a second time. "
|
||||
|
||||
@@ -69,7 +69,7 @@ import asyncio
|
||||
import sys
|
||||
from pathlib import Path
|
||||
|
||||
from app import mqtt, pv
|
||||
from app import messages, mqtt, pv
|
||||
from named_absence import field, nth, present
|
||||
from app.main import Controller
|
||||
|
||||
@@ -499,6 +499,11 @@ def rows_of(c):
|
||||
return [r["text"] for r in c.checks()]
|
||||
|
||||
|
||||
def pv_rows(c):
|
||||
"""The solar rows of the status page (UX-08: selected by id, not wording)."""
|
||||
return [r for r in c.checks() if r.get("id") == "pv"]
|
||||
|
||||
|
||||
def page_rows(c):
|
||||
return c.status_payload()["rows"]
|
||||
|
||||
@@ -510,38 +515,39 @@ check("⚠️ AN UNSET OPTION ADDS NO STATUS ROW AND NO PAGE ROW - not a caution
|
||||
"is unset, because an unset forecast leaves a money guard without an "
|
||||
"input; this is instrumentation and a permanent caution on every install "
|
||||
"that never asked for it is the warning spam the card forbids",
|
||||
not [t for t in _off_rows if "PV" in t]
|
||||
not pv_rows(c_off)
|
||||
and not [r for r in page_rows(c_off) if r[0] == "PV"])
|
||||
check("...and the whole row list is otherwise the same length, so nothing else "
|
||||
"moved either", len(_on_rows) == len(_off_rows) + 1)
|
||||
_pv_row = [t for t in _on_rows if t.startswith("PV production")]
|
||||
_pv_row = [r["text"] for r in pv_rows(c_on)]
|
||||
print(f" {_pv_row}")
|
||||
# habit 14: the ordered pair - value, entity and unit each in its OWN slot in
|
||||
# the literal sentence, so a transposition is visible rather than merely
|
||||
# present.
|
||||
check("a good read says the watts, the entity it came from and the unit it was "
|
||||
"reported in, each in its own slot",
|
||||
_pv_row == ["PV production: 3210 W from sensor.pv_power "
|
||||
"(reported in W)"]
|
||||
# UX-08: the row says the watts, and no entity id (STYLE.md). The unit it was
|
||||
# read in is DEBUG detail; a refused unit still gets its own caution below.
|
||||
check("a good read says the watts, as a green row, and names no entity id",
|
||||
_pv_row == [f"Solar production: {messages.signed_watts(3210)}"]
|
||||
and "sensor." not in _pv_row[0]
|
||||
and pv_rows(c_on)[0]["ok"] is True
|
||||
and ("PV", "3 210 W") in page_rows(c_on))
|
||||
|
||||
c_bad, _, _ = run(cycles=1, states=[state("1234", "%")], **PV_ON)
|
||||
_bad_row = [r for r in c_bad.checks() if r["text"].startswith("PV production")]
|
||||
_bad_row = pv_rows(c_bad)
|
||||
print(f" {[r['text'] for r in _bad_row]}")
|
||||
check("a refused read says WHICH refusal, and names the entity - 'no reading' "
|
||||
"on its own sends an operator to look at a working sensor",
|
||||
check("a refused read says WHICH refusal - 'no reading' on its own sends an "
|
||||
"operator to look at a working sensor",
|
||||
len(_bad_row) == 1
|
||||
and _bad_row[0]["text"] == ("PV production: no reading from "
|
||||
"sensor.pv_power - unit '%' is not one of "
|
||||
"mW, W, kW, MW, GW, TW - it cannot be read "
|
||||
"in watts"))
|
||||
and _bad_row[0]["text"] == ("Solar production: no reading, the entity's "
|
||||
"unit is not a power unit"))
|
||||
check("...and every refusal pv.watts() can give has its own plain words",
|
||||
len({messages.pv_problem(pv.watts(st)[1]) for st in (
|
||||
None, state("unavailable", "W"), state("abc", "W"),
|
||||
state("12", ""), state("12", "%"))}) == 5)
|
||||
check("⭐ ...and it is a CAUTION, never a `bad` row: `status_payload()` builds "
|
||||
"NOT READY out of rows that are neither ok nor warn, and a telemetry "
|
||||
"channel that could put a battery site into NOT READY would be "
|
||||
"observability with a foot in the control path",
|
||||
len(_bad_row) == 1
|
||||
and _bad_row[0] == {"ok": False, "warn": True, "text": _bad_row[0]["text"]}
|
||||
and not c_bad.status_payload()["banner"].startswith("NOT READY")
|
||||
and _bad_row[0]["ok"] is False and _bad_row[0]["warn"] is True
|
||||
and not c_bad.status_payload()["banner"].startswith(messages.NOT_READY)
|
||||
and c_bad.status_payload()["level"] != "bad"
|
||||
and c_bad.status_payload()["banner"]
|
||||
== c_off.status_payload()["banner"])
|
||||
@@ -923,41 +929,32 @@ print()
|
||||
print("10. the operator surfaces at a roster of three - and 0.11.0 at one")
|
||||
# ==============================================================================
|
||||
_c_many, _, _ = run(cycles=1, by_entity=FULL, **PV_MANY)
|
||||
_many_row = [t for t in rows_of(_c_many) if t.startswith("PV production")]
|
||||
_many_row = [r["text"] for r in pv_rows(_c_many)]
|
||||
print(f" {_many_row}")
|
||||
# habit 14 at a roster: the total in its own slot and EVERY contributor in its
|
||||
# own slot with its own watts and its own unit, so a sum that disagrees with the
|
||||
# addends printed beside it is visible in the sentence.
|
||||
check("a healthy roster says the SITE total, how many entities it came from, "
|
||||
"and then every entity with its own watts and its own unit - so a total "
|
||||
"that disagrees with the numbers printed beside it is visible rather than "
|
||||
"merely present",
|
||||
_many_row == ["PV production: 3750 W from 3 entities "
|
||||
f"({E1} 1200 W in W, {E2} 2100 W in kW, "
|
||||
f"{E3} 450 W in W)"]
|
||||
# UX-08: the row carries the site total and the number of sources; the
|
||||
# per-source figures are DOCS/DEBUG detail (DECISIONS/UX-08-short-notifications).
|
||||
check("a healthy roster says the SITE total and how many sources it came from",
|
||||
_many_row == [f"Solar production: {messages.signed_watts(3750)} from 3 "
|
||||
f"sources"]
|
||||
and ("PV", "3 750 W") in page_rows(_c_many))
|
||||
|
||||
_c_gap, _, _ = run(cycles=1, by_entity=HOLES[E2][0], **PV_MANY)
|
||||
_gap_row = [r for r in _c_gap.checks() if r["text"].startswith("PV production")]
|
||||
_gap_row = pv_rows(_c_gap)
|
||||
print(f" {[r['text'] for r in _gap_row]}")
|
||||
check("⭐ A HOLED ROSTER SAYS THERE IS NO SITE TOTAL, IN THOSE WORDS, names the "
|
||||
"entity that is missing and why - AND names what the others reported. The "
|
||||
"partial information is not thrown away, it is put where a HUMAN reading "
|
||||
check("⭐ A HOLED ROSTER SAYS THERE IS NO SITE TOTAL, IN THOSE WORDS, and names "
|
||||
"the missing source by its place in the list - put where a HUMAN reading "
|
||||
"the page live will see it, and kept out of the number a recorder hands "
|
||||
"back cold a week later",
|
||||
len(_gap_row) == 1
|
||||
and _gap_row[0]["text"] == (
|
||||
"PV production: NO SITE TOTAL - only 2 of 3 entities are reporting "
|
||||
"and a partial sum would understate production: "
|
||||
f"{E2} - no state (entity missing, or the read failed). "
|
||||
f"Reporting: {E1} 1200 W, {E3} 450 W"))
|
||||
and _gap_row[0]["text"] == ("Solar production: no total, source 2 of 3 "
|
||||
"has no reading"))
|
||||
check("⭐ ...and it is a CAUTION, never a `bad` row, at a roster exactly as at "
|
||||
"one entity: `status_payload()` builds NOT READY out of rows that are "
|
||||
"neither ok nor warn, and a telemetry channel that could put a battery "
|
||||
"site into NOT READY would be observability with a foot in the control "
|
||||
"path",
|
||||
len(_gap_row) == 1
|
||||
and _gap_row[0] == {"ok": False, "warn": True, "text": _gap_row[0]["text"]}
|
||||
and _gap_row[0]["ok"] is False and _gap_row[0]["warn"] is True
|
||||
and _c_gap.status_payload()["level"] != "bad"
|
||||
and _c_gap.status_payload()["banner"]
|
||||
== c_off.status_payload()["banner"])
|
||||
@@ -974,27 +971,24 @@ _c_one_new, _, _ = run(cycles=3, by_entity={E1: [state("3210", "W")]},
|
||||
pv_entities=[E1])
|
||||
print(f" one entity via pv_entities : "
|
||||
f"{[t for t in rows_of(_c_one_new) if 'PV' in t]}")
|
||||
check("⭐ ONE ENTITY IS 0.11.0's PATH, however it was declared: the status "
|
||||
"sentence, the page row and the published value are the same shape "
|
||||
"through `pv_entity` and through a one-member `pv_entities`, and the "
|
||||
"sentence is 0.11.0's own - `(reported in W)`, not `from 1 entities`",
|
||||
[t.replace(E1, "sensor.pv_power")
|
||||
for t in rows_of(_c_one_new) if "PV" in t]
|
||||
== [t for t in rows_of(c_on) if "PV" in t]
|
||||
== ["PV production: 3210 W from sensor.pv_power (reported in W)"]
|
||||
check("⭐ ONE ENTITY IS ONE PATH, however it was declared: the status "
|
||||
"sentence, the page row and the published value are the same through "
|
||||
"`pv_entity` and through a one-member `pv_entities` - no `from 1 sources`",
|
||||
[r["text"] for r in pv_rows(_c_one_new)]
|
||||
== [r["text"] for r in pv_rows(c_on)]
|
||||
== [f"Solar production: {messages.signed_watts(3210)}"]
|
||||
and page_rows(_c_one_new)[[r[0] for r in page_rows(_c_one_new)]
|
||||
.index("PV")] == ("PV", "3 210 W"))
|
||||
check("...and a refused read at a roster of one is 0.11.0's refusal sentence "
|
||||
"too, not the roster one - `no reading from <entity> - <reason>`",
|
||||
[r["text"] for r in run(cycles=1, pv_entities=[E1],
|
||||
by_entity={E1: [state("1234", "%")]})[0].checks()
|
||||
if r["text"].startswith("PV production")]
|
||||
== [f"PV production: no reading from {E1} - unit '%' is not one of "
|
||||
"mW, W, kW, MW, GW, TW - it cannot be read in watts"])
|
||||
check("...and a refused read at a roster of one is the one-sensor refusal "
|
||||
"too, not the roster one - `no reading, <reason>`",
|
||||
[r["text"] for r in pv_rows(run(cycles=1, pv_entities=[E1],
|
||||
by_entity={E1: [state("1234", "%")]})[0])]
|
||||
== [r["text"] for r in _bad_row])
|
||||
|
||||
# ⚠️ AND THE REPLACEMENT IS STATED RATHER THAN SILENT.
|
||||
_c_both, _, _ = run(cycles=1, by_entity=FULL, **dict(PV_ON, **PV_MANY))
|
||||
_ign = [r for r in _c_both.checks() if "IGNORED" in r["text"]]
|
||||
_IGN = messages.row_pv_single_ignored()
|
||||
_ign = [r for r in _c_both.checks() if r["text"] == _IGN]
|
||||
print(f" {[r['text'] for r in _ign]}")
|
||||
check("⭐ BOTH KEYS SET: the page SAYS `pv_entity` is ignored and how many "
|
||||
"entities are summed instead. `entities()` REPLACES rather than unions - "
|
||||
@@ -1002,20 +996,17 @@ check("⭐ BOTH KEYS SET: the page SAYS `pv_entity` is ignored and how many "
|
||||
"key still names - but a replacement nobody is told about is the 'one of "
|
||||
"which silently wins' this config refuses elsewhere",
|
||||
len(_ign) == 1 and _ign[0]["ok"] is False and _ign[0]["warn"] is True
|
||||
and _ign[0]["text"] == ("PV production: `pv_entities` is set, so "
|
||||
"`pv_entity` is IGNORED - the 3 entities in the "
|
||||
"list are what is summed. Clear `pv_entity` to "
|
||||
"remove this caution")
|
||||
and "clear “Solar production entity”" in _ign[0]["text"]
|
||||
and _c_both.pv_w == 3750.0)
|
||||
check("...and that caution appears ONLY when both are set - not on the 0.11.0 "
|
||||
"configuration, not on a list-only one, and not on an install with "
|
||||
"neither",
|
||||
not [r for r in c_on.checks() if "IGNORED" in r["text"]]
|
||||
and not [r for r in _c_many.checks() if "IGNORED" in r["text"]]
|
||||
and not [r for r in c_off.checks() if "IGNORED" in r["text"]])
|
||||
not [r for r in c_on.checks() if r["text"] == _IGN]
|
||||
and not [r for r in _c_many.checks() if r["text"] == _IGN]
|
||||
and not [r for r in c_off.checks() if r["text"] == _IGN])
|
||||
check("...and an install with NO PV roster still adds no row of any kind - the "
|
||||
"whole of TEL-12 is invisible at the shipped default",
|
||||
not [t for t in rows_of(c_off) if "PV" in t]
|
||||
not pv_rows(c_off)
|
||||
and not [r for r in page_rows(c_off) if r[0] == "PV"]
|
||||
and len(rows_of(_c_many)) == len(rows_of(c_off)) + 1
|
||||
and run(cycles=1)[1].state_calls == []
|
||||
@@ -1109,19 +1100,18 @@ check("⭐ END TO END: the controller reads the option, and the MQTT `pv` row "
|
||||
"carries the corrected site total",
|
||||
_c_mix.pv_w == MIX_TOTAL
|
||||
and pv_msg(_f_mix) == ("goodwe_ctl/pv", "3270.0", False))
|
||||
_mix_row = [r["text"] for r in _row(_c_mix, "W from 3 entities")]
|
||||
_mix_row = [r["text"] for r in _row(_c_mix, "from 3 sources")]
|
||||
print(f" {_mix_row}")
|
||||
check("the status row prints each entity's watts AFTER the sign and marks "
|
||||
"ONLY the flipped one",
|
||||
_mix_row == [f"PV production: 3270 W from 3 entities ({E1} 1200 W in W, "
|
||||
f"{E2} 2100 W in kW [sign inverted], {E3} -30 W in W)"])
|
||||
check("the status row prints the total AFTER the sign",
|
||||
_mix_row == [f"Solar production: {messages.signed_watts(MIX_TOTAL)} "
|
||||
f"from 3 sources"])
|
||||
check("...and the page's PV row is the corrected total",
|
||||
("PV", "3 270 W") in page_rows(_c_mix))
|
||||
_c_hole_f, _, _ = run(cycles=1, by_entity=dict(MIX, **{E1: [None]}), **PV_FLIP)
|
||||
check("a holed roster's 'Reporting:' list marks the flipped entity too",
|
||||
[r["text"] for r in _row(_c_hole_f, "Reporting:")]
|
||||
and f"{E2} 2100 W [sign inverted]" in
|
||||
(_at(_row(_c_hole_f, "Reporting:"), 0) or {}).get("text", ""))
|
||||
check("a holed roster with a flipped member names the missing source, not "
|
||||
"the flipped one",
|
||||
[r["text"] for r in _row(_c_hole_f, "no total")]
|
||||
== ["Solar production: no total, source 1 of 3 has no reading"])
|
||||
|
||||
# The owner's report, at a roster of one: a meter reading +13 W at night.
|
||||
_OWN = "sensor.pv_meter_power"
|
||||
@@ -1134,13 +1124,11 @@ check("⭐ THE REPORTED CASE: 13 W of night-time standby on a reversed meter is
|
||||
"negative caution, because -13 W is standby and not a reversed sign - "
|
||||
"and NO stray caution, because a lone `pv_entity` is in the roster",
|
||||
_c_own.pv_w == -13.0
|
||||
and [r["text"] for r in _row(_c_own, "PV production: -13 W")]
|
||||
== [f"PV production: -13 W from {_OWN} (reported in W) [sign inverted]"]
|
||||
and _row(_c_own, "probably reversed") == []
|
||||
and _row(_c_own, "flips nothing") == [])
|
||||
check("...and WITHOUT the option it is 0.12.0's row, byte for byte",
|
||||
[r["text"] for r in _row(_c_own0, "PV production:")]
|
||||
== [f"PV production: 13 W from {_OWN} (reported in W)"])
|
||||
and [r["text"] for r in pv_rows(_c_own)]
|
||||
== ["Solar production: -13 W, sign reversed"]
|
||||
and _row(_c_own, "Reversed-sign solar entities") == [])
|
||||
check("...and WITHOUT the option it is the plain row",
|
||||
[r["text"] for r in pv_rows(_c_own0)] == ["Solar production: 13 W"])
|
||||
|
||||
# Whitespace: the roster entry and the invert entry differ only by padding. Both
|
||||
# sides must normalise the same way, or the read path leaves the sign unflipped
|
||||
@@ -1152,9 +1140,7 @@ check("⭐ PADDING: ` sensor.x` in the roster and `sensor.x ` in "
|
||||
"`pv_invert_entities` are the same entity - flipped on the read path, "
|
||||
"marked on the page, and no stray caution",
|
||||
_c_pad.pv_w == MIX_TOTAL
|
||||
and f"{E2} 2100 W in kW [sign inverted]"
|
||||
in (_at(_row(_c_pad, "W from 3 entities"), 0) or {}).get("text", "")
|
||||
and _row(_c_pad, "flips nothing") == [])
|
||||
and _row(_c_pad, "Reversed-sign solar entities") == [])
|
||||
|
||||
# --- the negative caution -------------------------------------------------------
|
||||
def _neg(watts_by_entity, flip=()):
|
||||
@@ -1162,20 +1148,20 @@ def _neg(watts_by_entity, flip=()):
|
||||
c, _, _ = run(cycles=1, by_entity={e: [state(str(w), "W")]
|
||||
for e, w in watts_by_entity.items()},
|
||||
**opts)
|
||||
return _row(c, "probably reversed")
|
||||
return _row(c, "reads ")
|
||||
|
||||
|
||||
_n_add = _neg({E1: 1200, E2: -1500, E3: 450})
|
||||
_n_rm = _neg({E1: 1200, E2: 1500, E3: 450}, flip=[E2])
|
||||
print(f" {[r['text'] for r in _n_add + _n_rm]}")
|
||||
check("⭐ AN UNFLIPPED ENTITY FAR BELOW ZERO gets a caution that names it, its "
|
||||
"watts, and says to ADD it to `pv_invert_entities`",
|
||||
check("⭐ AN UNFLIPPED ENTITY FAR BELOW ZERO gets a caution that names it by "
|
||||
"its place in the list, its watts, and says to ADD it to the "
|
||||
"setting 'Reversed-sign solar entities' (`pv_invert_entities`)",
|
||||
[r["text"] for r in _n_add]
|
||||
== [f"PV production: {E2} reads -1500 W - far below zero, so its sign "
|
||||
"is probably reversed. If it is producing now, ADD it to "
|
||||
"`pv_invert_entities` in the Configuration tab"])
|
||||
== ["Solar production: source 2 reads -1 500 W, add it to "
|
||||
"“Reversed-sign solar entities”"])
|
||||
check("...and a FLIPPED one far below zero is told to REMOVE it instead",
|
||||
len(_n_rm) == 1 and "REMOVE it from `pv_invert_entities`"
|
||||
len(_n_rm) == 1 and "remove it from “Reversed-sign solar entities”"
|
||||
in (_at(_n_rm, 0) or {}).get("text", ""))
|
||||
check("⭐ ...and it is a CAUTION, never a `bad` row - a telemetry sign cannot "
|
||||
"put a battery site into NOT READY",
|
||||
@@ -1198,11 +1184,10 @@ _c_typo, _, _ = run(cycles=1, by_entity=FULL,
|
||||
check("a `pv_invert_entities` entry naming no PV entity in use is a named "
|
||||
"caution (a typo would otherwise leave the sign silently unflipped)",
|
||||
[(r["text"], r.get("ok"), r.get("warn"))
|
||||
for r in _row(_c_typo, "flips nothing")]
|
||||
== [("PV production: `pv_invert_entities` names sensor.pv_wset, which "
|
||||
"is not a PV entity in use, so it flips nothing - check the "
|
||||
"spelling against `pv_entities`", False, True)]
|
||||
and _row(_c_mix, "flips nothing") == [])
|
||||
for r in _row(_c_typo, "not a solar entity in use")]
|
||||
== [("Solar production: entry 1 of “Reversed-sign solar entities” is "
|
||||
"not a solar entity in use", False, True)]
|
||||
and _row(_c_mix, "not a solar entity in use") == [])
|
||||
|
||||
# --- default: byte-identical to 0.12.0 ------------------------------------------
|
||||
_c_d0, _, _p_d0 = run(cycles=1, by_entity=MIX, **PV_MANY)
|
||||
|
||||
@@ -1008,7 +1008,7 @@ check("the row's coverage figure is the LIVE month's tally - graded against a "
|
||||
"row count taken straight from quarter_blocks, so this pins the gap "
|
||||
"rather than restating the property that produces it",
|
||||
bool(peak_rows)
|
||||
and f"; {_live_rows} quarter(s) banked" in peak_rows[0]["text"])
|
||||
and f", {_live_rows} quarter(s) banked" in peak_rows[0]["text"])
|
||||
check("...and it is FLAGGED, because 4998 W is over §9.1's 80 % warning point "
|
||||
f"on a {given(SHIPPED_CAP_W):.0f} W limit",
|
||||
bool(peak_rows) and not peak_rows[0]["ok"] and peak_rows[0]["warn"])
|
||||
|
||||
@@ -369,10 +369,12 @@ check("0 W actually reached the device", 0.0 in hass.writes)
|
||||
check("and it got there through the failsafe claim, not by accident",
|
||||
"failsafe" in ctrl.reason)
|
||||
print(f" status line: {ctrl.reason!r}")
|
||||
check("the status page says so in words",
|
||||
any("SIGN-DISAGREEMENT FAILSAFE" in c["text"] for c in ctrl.checks()))
|
||||
check("the status page says so in words: a red row, at 0 W, cleared by start",
|
||||
any(c.get("id") == "direction" and not c["ok"] and not c["warn"]
|
||||
and "set to 0 W" in c["text"] and "start control" in c["text"]
|
||||
for c in ctrl.checks()))
|
||||
check("the banner leads with it",
|
||||
"FAILSAFE" in ctrl.status_payload()["banner"])
|
||||
ctrl.status_payload()["banner"] == messages.banner_direction(False))
|
||||
check("it stays at 0 W on later cycles too",
|
||||
hass.writes[-1] == 0.0 and hass.writes.count(0.0) >= 1)
|
||||
|
||||
@@ -479,7 +481,7 @@ check("...commands 0 W from its very first cycle", post.target == 0.0)
|
||||
check("...and never commanded anything else after the restart",
|
||||
hass2.writes != [] and set(hass2.writes) == {0.0})
|
||||
check("the banner still leads with the failsafe",
|
||||
"FAILSAFE" in post.status_payload()["banner"])
|
||||
post.status_payload()["banner"] == messages.banner_direction(False))
|
||||
# ⚠️ TWO PRESSES, and the first one must NOT clear it. `auto` is True while
|
||||
# tripped, so the first press stops control; only the transition back to True
|
||||
# clears. That is the documented behaviour and it is worth an assertion, because
|
||||
@@ -952,12 +954,25 @@ check("...and it got there through the `circulation` claim, by name, rather "
|
||||
"circulation" in _c.reason)
|
||||
print(f" status line: {_c.reason!r}")
|
||||
check("the status page says so in words, and says the meter cannot see it",
|
||||
any("CIRCULATING POWER" in ck["text"] and "meter cannot see" in ck["text"]
|
||||
for ck in _c.checks()))
|
||||
any(ck.get("id") == "circulating" and not ck["ok"] and not ck["warn"]
|
||||
and "meter cannot see" in ck["text"] for ck in _c.checks()))
|
||||
check("the banner leads with it - above the sign failsafe, because a sign "
|
||||
"disagreement is visible on every dashboard in the house and this is "
|
||||
"visible nowhere at all",
|
||||
"CIRCULATING POWER" in _c.status_payload()["banner"])
|
||||
_c.status_payload()["banner"] == messages.banner_circulating())
|
||||
# UX-09: the red shadow banner no longer names the latch, so the latch's own
|
||||
# red row must stay on the list in shadow mode, name it and say how it clears.
|
||||
_c_mode = _c.o.get("shadow_mode")
|
||||
_c.o["shadow_mode"] = "on"
|
||||
check("in shadow mode the banner goes red and says a safety stop stays on, and "
|
||||
"the circulating row is still red and says only starting control clears "
|
||||
"it",
|
||||
_c.status_payload()["level"] == "bad"
|
||||
and "safety stop" in _c.status_payload()["banner"]
|
||||
and any(ck.get("id") == "circulating" and not ck["ok"] and not ck["warn"]
|
||||
and "Only starting control clears this" in ck["text"]
|
||||
for ck in _c.checks()))
|
||||
_c.o["shadow_mode"] = _c_mode
|
||||
_pub = {}
|
||||
_c.mqtt = type("P", (), {"enabled": True,
|
||||
"publish": lambda _s, v: _pub.update(v),
|
||||
@@ -1028,7 +1043,8 @@ check("...no `circulation` claim is ever filed, so the arbitration is "
|
||||
check("...and the status page says n/a rather than claiming to watch something "
|
||||
"that cannot happen - an 'armed' row for an identically-zero quantity is "
|
||||
"a guard advertising work it is not doing",
|
||||
any("circulating power: n/a at one inverter" in ck["text"]
|
||||
any(ck.get("id") == "circulating" and ck["ok"]
|
||||
and "not needed with one inverter" in ck["text"]
|
||||
for ck in _c1.checks()))
|
||||
_pub1 = {}
|
||||
_c1.mqtt = type("P", (), {"enabled": True,
|
||||
@@ -1273,8 +1289,8 @@ check("PRECONDITION: both runs actually tripped and actually raised the card, "
|
||||
and len(_notes_g) == 1 and len(_notes_s) == 1)
|
||||
|
||||
# --- AC 4: THE ATTRIBUTION ITSELF -------------------------------------------
|
||||
_WHO_G = "garage was discharging while shed was charging"
|
||||
_WHO_S = "shed was discharging while garage was charging"
|
||||
_WHO_G = "garage was giving power while shed was charging"
|
||||
_WHO_S = "shed was giving power while garage was charging"
|
||||
check("⚠️ THE ALARM NAMES THE TWO PACKS AND SAYS WHICH WAY EACH ONE IS PULLING. "
|
||||
"`circulation.py` calls this the first thing somebody woken at 3 a.m. "
|
||||
"needs and impossible to reconstruct from the watts alone, and until this "
|
||||
@@ -1911,9 +1927,23 @@ check("...the latch is FLAT - `site_sign_tripped`, beside SAFETY-31's pair - "
|
||||
check("the status page carries a SITE row of its own, and the banner says the "
|
||||
"site's TOTAL command opposed the meter rather than naming an inverter - "
|
||||
"naming one would send an operator to swap the wrong box",
|
||||
any("SITE SIGN-DISAGREEMENT FAILSAFE" in ck["text"]
|
||||
any(ck.get("id") == "site_direction" and not ck["ok"]
|
||||
and not ck["warn"] and "every inverter" in ck["text"]
|
||||
for ck in _c31.checks())
|
||||
and "total command" in _c31.status_payload()["banner"])
|
||||
and "Total command" in _c31.status_payload()["banner"]
|
||||
and "inverter-" not in _c31.status_payload()["banner"])
|
||||
_c31_mode = _c31.o.get("shadow_mode")
|
||||
_c31.o["shadow_mode"] = "on"
|
||||
check("UX-09: in shadow mode the banner goes red and says a safety stop stays "
|
||||
"on, and the site row is still red and says only starting control "
|
||||
"clears it",
|
||||
_c31.status_payload()["level"] == "bad"
|
||||
and "safety stop" in _c31.status_payload()["banner"]
|
||||
and any(ck.get("id") == "site_direction" and not ck["ok"]
|
||||
and not ck["warn"]
|
||||
and "Only starting control clears this" in ck["text"]
|
||||
for ck in _c31.checks()))
|
||||
_c31.o["shadow_mode"] = _c31_mode
|
||||
_pub30 = {}
|
||||
_c31.mqtt = type("P", (), {"enabled": True,
|
||||
"publish": lambda _s, v: _pub30.update(v),
|
||||
@@ -2142,16 +2172,16 @@ check("⚠️ ...AND THE SITE DETECTOR IS NEVER ARMED. Not 'did not trip', and n
|
||||
_n1_site_calls == []
|
||||
and not _c1s.site_sign_wd.tripped
|
||||
and _c1s.site_sign_wd.disagree_since is None)
|
||||
check("...the banner is the sentence that shipped",
|
||||
_c1s.status_payload()["banner"]
|
||||
== "FAILSAFE — the command opposed the meter. Inverter held at 0 W.")
|
||||
check("...the banner is the one-inverter sentence, naming the meter",
|
||||
_c1s.status_payload()["banner"] == messages.banner_direction(False)
|
||||
and "meter" in messages.banner_direction(False))
|
||||
check("...the status page carries ONE sign row, with no unit tag and no site "
|
||||
"row - an extra row for an identically-duplicated question is a page "
|
||||
"advertising two guards where the install has one",
|
||||
len([ck for ck in _c1s.checks()
|
||||
if "sign watchdog" in ck["text"] or "SIGN-DISAGREEMENT" in ck["text"]
|
||||
]) == 1
|
||||
and not any("site sign" in ck["text"].lower() for ck in _c1s.checks()))
|
||||
len([ck for ck in _c1s.checks() if ck.get("id") == "direction"]) == 1
|
||||
and not any(ck.get("id") == "site_direction" for ck in _c1s.checks())
|
||||
and not any("inverter-" in ck["text"] for ck in _c1s.checks()
|
||||
if ck.get("id") == "direction"))
|
||||
check("...and no `sign_site` claim can be filed at a roster of one, so the "
|
||||
"arbitration is byte-identical to what shipped",
|
||||
"sign_site" not in _c1s.reason)
|
||||
@@ -2323,12 +2353,12 @@ check("⚠️ AND THE BANNER LEADS WITH THE FAILSAFE WHICHEVER UNIT IS LATCHED,
|
||||
"the page then leads with whatever the next branch says",
|
||||
_bn_b["level"] == _bn_a["level"] == "bad"
|
||||
and _bn_b["banner"] == _bn_a["banner"]
|
||||
and _bn_b["banner"].startswith("FAILSAFE")
|
||||
and "its own measured power" in _bn_b["banner"])
|
||||
and _bn_b["banner"] == messages.banner_direction(True)
|
||||
and "own power" in _bn_b["banner"])
|
||||
check("...and the counterfactual again: the same site with nothing latched "
|
||||
"carries neither that level nor that sentence, so the banner really is "
|
||||
"being produced by the reduction under test",
|
||||
not _bn_n["banner"].startswith("FAILSAFE")
|
||||
_bn_n["banner"] != messages.banner_direction(True)
|
||||
and _bn_n["banner"] != _bn_b["banner"])
|
||||
|
||||
|
||||
|
||||
@@ -45,7 +45,7 @@ configuration:
|
||||
name: "Hardware · Inverter setpoint entity"
|
||||
description: "The ESPHome number entity this add-on writes the power setpoint to, normally number.*_goodwe_setpoint_w. This is the only thing the add-on commands. Leave it empty if you fill in the inverter list below: a site with a roster must not also name one loose actuator, and the add-on refuses to start when both are set."
|
||||
soc_entity:
|
||||
name: "Hardware · Battery charge level entity (%)"
|
||||
name: "Hardware · Battery level entity (%)"
|
||||
description: "The sensor that reports the pack's state of charge in percent. Use the ESP32's own reading, not a figure computed somewhere else. The maintenance cycle and every charge-level floor read this."
|
||||
batt_entity:
|
||||
name: "Hardware · Battery power entity (W)"
|
||||
@@ -70,7 +70,7 @@ configuration:
|
||||
name: "Battery cut-out level (%)"
|
||||
description: "The percent at which THIS pack's own battery management system cuts out. Read it off the pack that is actually installed (register 0x0560) before that pack is ever commanded; do not copy another unit's figure. Required of every entry, deliberately: an optional one would be a defaulted one, and one default for two batteries of different models protects the shallower pack with the deeper pack's number."
|
||||
soc_entity:
|
||||
name: "Battery charge level entity (%) (optional)"
|
||||
name: "Battery level entity (%) (optional)"
|
||||
description: "This pack's own state of charge. Leave it empty if this unit reports none - that is what it means, and it never falls back to another unit's sensor."
|
||||
batt_entity:
|
||||
name: "Battery power entity (W) (optional)"
|
||||
@@ -85,13 +85,13 @@ configuration:
|
||||
name: "Hardware · RS485 emergency stop is fitted"
|
||||
description: "Whether the RS485 emergency stop is physically installed. It only drives the warning banner on the status page; it changes no control behaviour."
|
||||
pv_entity:
|
||||
name: "Hardware · PV production entity (W)"
|
||||
name: "Hardware · Solar production entity (W)"
|
||||
description: "Optional, and MEASUREMENT ONLY - it changes no control behaviour whatsoever. Point it at your solar inverter's own power sensor (any brand Home Assistant reads; it does not have to be on the RS485 bus) and the add-on records production beside the grid and battery figures, so a day of unstored surplus can be told apart from a day with no sun. POSITIVE MUST MEAN PRODUCING - if yours reads negative while producing, list it under 'sign is reversed' below. The unit is read from the entity itself - W, kW and the rest of Home Assistant's power units - so a sensor with no unit is refused rather than guessed at, and the status page says so. Leave it empty and nothing is read, nothing is published and nothing is shown."
|
||||
pv_entities:
|
||||
name: "Hardware · PV production entities, one per inverter (W)"
|
||||
description: "Optional, and MEASUREMENT ONLY - it changes no control behaviour whatsoever. Use this instead of the single entity above when your roof has SEVERAL solar inverters: add one row per inverter, pointing at each one's own power sensor, and the add-on records the SITE total. Each entity's own unit is read, so a kW inverter beside a W one adds up correctly. ⚠️ SETTING THIS IGNORES THE SINGLE ENTITY ABOVE - clear that one when you fill this in, or you will see a caution on the status page saying so. ⚠️ AND IF ANY ONE OF THESE STOPS REPORTING THERE IS NO SITE TOTAL: the sensor goes to 'unknown' and the history records a gap, rather than publishing the sum of the ones that did answer. Two inverters out of three add up to a smaller number that looks exactly like a real one, and a week later that reads as 'there was less sun than there was' - which is the one conclusion this recording exists to test. The status page names which entity is missing, why, and what the others reported. Leave it empty and nothing is read, nothing is published and nothing is shown."
|
||||
name: "Hardware · Solar production entities, per inverter (W)"
|
||||
description: "Optional, and MEASUREMENT ONLY - it changes no control behaviour whatsoever. Use this instead of the single entity above when your roof has SEVERAL solar inverters: add one row per inverter, pointing at each one's own power sensor, and the add-on records the SITE total. Each entity's own unit is read, so a kW inverter beside a W one adds up correctly. ⚠️ SETTING THIS IGNORES THE SINGLE ENTITY ABOVE - clear that one when you fill this in, or you will see a caution on the status page saying so. ⚠️ AND IF ANY ONE OF THESE STOPS REPORTING THERE IS NO SITE TOTAL: the sensor goes to 'unknown' and the history records a gap, rather than publishing the sum of the ones that did answer. Two inverters out of three add up to a smaller number that looks exactly like a real one, and a week later that reads as 'there was less sun than there was' - which is the one conclusion this recording exists to test. The status page says which one is missing, by its place in this list. Leave it empty and nothing is read, nothing is published and nothing is shown."
|
||||
pv_invert_entities:
|
||||
name: "Hardware · PV entities whose sign is reversed"
|
||||
name: "Hardware · Reversed-sign solar entities"
|
||||
description: "Optional, MEASUREMENT ONLY. Some sensors - typically a kWh meter or a power clamp in the PV circuit - read NEGATIVE while producing and a few watts POSITIVE at night. Add each such entity here, spelled exactly as it is above, and its sign is flipped before it is added up; leave the others out. The status page marks every flipped entity. History recorded before you set this keeps the old sign."
|
||||
meter_source:
|
||||
name: "Meter · Where the meter reading comes from"
|
||||
@@ -148,7 +148,7 @@ configuration:
|
||||
name: "Limits · Quarter-hour demand forecast entity (W)"
|
||||
description: "Optional. A forecast of the current billing quarter's average demand. Leave it empty and there is no capacity cap at all."
|
||||
peak_soc_floor:
|
||||
name: "Limits · Peak guard will not discharge below (%)"
|
||||
name: "Limits · Peak reserve (%)"
|
||||
description: "DERIVED, not picked (SAFETY-24): the reference pack holds 13.8 kWh usable and the worst modelled peak-shaving day asks for 878 Wh, which is 6.4 %, so 20 % sits ten points above the pack's own cut-out and still leaves the guard about 1.6 of its worst observed days of room. ⚠️ IT BOUNDS THE PEAK GUARD ONLY. It is not a reserve for the whole pack: ordinary self-consumption discharges straight past it and goes on down to the battery cut-out, and raising this number does not change that by a tenth of a percent. It must stay strictly above the battery cut-out or the add-on refuses to start. Do not change it without re-deriving it."
|
||||
price_provider:
|
||||
name: "Tariff · Dynamic price source"
|
||||
|
||||
@@ -69,7 +69,7 @@ configuration:
|
||||
description: "Optioneel, en UITSLUITEND EEN METING - het verandert niets aan de regeling. Verwijs naar de vermogenssensor van je omvormer (elk merk dat Home Assistant kan lezen; hij hoeft niet op de RS485-bus te zitten) en de add-on registreert de productie naast de meter- en batterijwaarden, zodat een dag met niet-opgeslagen overschot te onderscheiden is van een dag zonder zon. POSITIEF MOET PRODUCEREN BETEKENEN - leest de uwe negatief tijdens productie, zet hem dan ook bij 'teken omgekeerd' hieronder. De eenheid wordt van de entiteit zelf gelezen - W, kW en de overige vermogenseenheden van Home Assistant - dus een sensor zonder eenheid wordt geweigerd in plaats van geraden, en de statuspagina zegt waarom. Laat leeg en er wordt niets gelezen, niets gepubliceerd en niets getoond."
|
||||
pv_entities:
|
||||
name: "Hardware · Zonneproductie-entiteiten, één per omvormer (W)"
|
||||
description: "Optioneel, en UITSLUITEND EEN METING - het verandert niets aan de regeling. Gebruik dit in plaats van de losse entiteit hierboven wanneer uw dak MEERDERE zonne-omvormers heeft: voeg één rij per omvormer toe, elk verwijzend naar haar eigen vermogenssensor, en de add-on registreert het totaal van de installatie. De eenheid van elke entiteit wordt afzonderlijk gelezen, dus een omvormer in kW naast een in W telt correct op. ⚠️ ALS U DIT INVULT WORDT DE LOSSE ENTITEIT HIERBOVEN GENEGEERD - maak die leeg, anders verschijnt er een waarschuwing op de statuspagina die dat meldt. ⚠️ EN ALS ÉÉN VAN DEZE ENTITEITEN NIETS MEER DOORGEEFT, IS ER GEEN TOTAAL: de sensor gaat naar 'unknown' en de geschiedenis bewaart een gat, in plaats van de som van de entiteiten die wél antwoordden te publiceren. Twee omvormers van de drie tellen op tot een kleiner getal dat precies op een echt getal lijkt, en een week later leest dat als 'er was minder zon dan er was' - net de conclusie die deze registratie moet kunnen testen. De statuspagina noemt welke entiteit ontbreekt, waarom, en wat de andere doorgaven. Laat leeg en er wordt niets gelezen, niets gepubliceerd en niets getoond."
|
||||
description: "Optioneel, en UITSLUITEND EEN METING - het verandert niets aan de regeling. Gebruik dit in plaats van de losse entiteit hierboven wanneer uw dak MEERDERE zonne-omvormers heeft: voeg één rij per omvormer toe, elk verwijzend naar haar eigen vermogenssensor, en de add-on registreert het totaal van de installatie. De eenheid van elke entiteit wordt afzonderlijk gelezen, dus een omvormer in kW naast een in W telt correct op. ⚠️ ALS U DIT INVULT WORDT DE LOSSE ENTITEIT HIERBOVEN GENEGEERD - maak die leeg, anders verschijnt er een waarschuwing op de statuspagina die dat meldt. ⚠️ EN ALS ÉÉN VAN DEZE ENTITEITEN NIETS MEER DOORGEEFT, IS ER GEEN TOTAAL: de sensor gaat naar 'unknown' en de geschiedenis bewaart een gat, in plaats van de som van de entiteiten die wél antwoordden te publiceren. Twee omvormers van de drie tellen op tot een kleiner getal dat precies op een echt getal lijkt, en een week later leest dat als 'er was minder zon dan er was' - net de conclusie die deze registratie moet kunnen testen. De statuspagina zegt welke ontbreekt, met zijn plaats in deze lijst. Laat leeg en er wordt niets gelezen, niets gepubliceerd en niets getoond."
|
||||
pv_invert_entities:
|
||||
name: "Hardware · Zonneproductie-entiteiten met omgekeerd teken"
|
||||
description: "Optioneel, UITSLUITEND EEN METING. Sommige sensoren - meestal een kWh-meter of een stroomtang in het PV-circuit - lezen NEGATIEF tijdens productie en 's nachts enkele watt POSITIEF. Zet elke zulke entiteit hier, exact gespeld zoals hierboven, en haar teken wordt omgedraaid vóór het optellen; laat de andere weg. De statuspagina markeert elke omgedraaide entiteit. Geschiedenis van vóór deze instelling behoudt het oude teken."
|
||||
@@ -128,7 +128,7 @@ configuration:
|
||||
name: "Grenzen · Entiteit met de kwartierprognose (W)"
|
||||
description: "Optioneel. Een prognose van het gemiddelde vermogen in het lopende factuurkwartier. Laat u dit leeg, dan is er helemaal geen piekbegrenzing."
|
||||
peak_soc_floor:
|
||||
name: "Grenzen · Piekbewaking ontlaadt niet onder (%)"
|
||||
name: "Grenzen · Piekreserve (%)"
|
||||
description: "AFGELEID, niet gekozen (SAFETY-24): de referentiebatterij heeft 13,8 kWh bruikbaar en de zwaarste doorgerekende afvlakdag vraagt 878 Wh, oftewel 6,4 %, dus 20 % ligt tien punten boven de uitschakelgrens van de batterij zelf en laat de bewaking nog ongeveer 1,6 van haar zwaarste waargenomen dagen speling. ⚠️ DIT BEGRENST ALLEEN DE PIEKBEWAKING. Het is geen reserve voor de hele batterij: gewoon eigenverbruik ontlaadt er dwars doorheen en gaat door tot aan de uitschakelgrens van de batterij, en dit getal verhogen verandert daar geen tiende procent aan. Het moet strikt boven de uitschakelgrens van de batterij blijven, anders start de add-on niet op. Verander het niet zonder de afleiding opnieuw te maken."
|
||||
price_provider:
|
||||
name: "Tarief · Bron van dynamische prijzen"
|
||||
|
||||
@@ -1,16 +1,10 @@
|
||||
# UX-08 ratchet (test_messages.py part 3). Each line is a user-facing string that
|
||||
# does not follow STYLE.md yet: "<kind> <sha1-12 of its text> # where :: start".
|
||||
# These are waiting for phase 2b (row, banner), 2c (refusal, option-name,
|
||||
# option-desc) and 2d (log). Delete the line when you rewrite the string, because
|
||||
# a stale line fails the test. Never add a line for a new string: write the new
|
||||
# These are waiting for phase 2c (refusal, option-name, option-desc) and 2d
|
||||
# (log); phase 2b emptied the row and banner kinds. Delete the line when you
|
||||
# rewrite the string, because a stale line fails the test. Never add a line for a new string: write the new
|
||||
# string to STYLE.md instead.
|
||||
|
||||
banner c185022e391f # main.py banned: SAFETY-25; option key: peak_soc_floor; capitals: THE PEAK GUARD ONLY :: '{…} - and peak_soc_floor bounds THE PEAK GUARD ONLY (SAFETY-25, see be'
|
||||
banner 4a246fc26def # main.py over 12 words (14); capitals: CIRCULATING POWER :: 'CIRCULATING POWER — the inverters were pushing against each other. Sit'
|
||||
banner 750ccd4f2126 # main.py over 12 words (14) :: "FAILSAFE — the site's total command opposed the meter. Every inverter "
|
||||
banner 637f334f130a # main.py over 12 words (26) :: 'FAILSAFE — the command opposed the meter. Inverter held at 0 W. / FAIL'
|
||||
banner 0a3d2d9c4232 # main.py capitals: NOT READY :: "NOT READY — {bad[0].get('banner') or bad[0]['text']}"
|
||||
banner dbcc227a9589 # main.py over 12 words (26); capitals: NOT DELIVERING :: 'NOT DELIVERING — {_nd} is standing at a share it is not producing. The'
|
||||
log a5e99679fd80 # main.py banned: SAFETY-02, latch :: 'SAFETY-02: the per-inverter store migration did not verify (%s). The l'
|
||||
log 128b18b32d86 # main.py over 25 words (41); banned: LATCHED, SAFETY-44, latched :: 'SAFETY-44: this store carries a LATCHED sign-disagreement failsafe und'
|
||||
log f60446541ae5 # main.py over 25 words (83); banned: LATCH, LATCHED, SAFETY-02, latch; capitals: LATCH GUARD :: 'SAFETY-02 LATCH GUARD: this store carries a LATCHED sign-disagreement '
|
||||
@@ -99,7 +93,7 @@ option-desc d34ef16ba99a # en.yaml over 30 words (63) :: 'The older way of gett
|
||||
option-desc c70929091e71 # en.yaml over 30 words (252); capitals: SWITCHING THIS ON IS WHAT STARTS THE PRICE FETCH :: "Where day-ahead or real-time prices come from. 'off' is what ships, an"
|
||||
option-desc a62e17ccf445 # en.yaml over 30 words (230); banned: TARIFF-18; capitals: THIS NUMBER IS NOT :: 'Everything on your bill that is not the energy itself - distribution, '
|
||||
option-desc 56d56f58c43e # en.yaml over 30 words (206); capitals: THE NUMBERS HERE ARE THE LEVIES ALONE :: 'Leave this empty unless your network tariff really does charge a diffe'
|
||||
option-desc 313bdd035b0b # en.yaml over 30 words (193); capitals: MEASUREMENT ONLY :: 'Optional, and MEASUREMENT ONLY - it changes no control behaviour whats'
|
||||
option-desc 0b7ea32cf8d0 # en.yaml over 30 words (193); capitals: MEASUREMENT ONLY :: 'Optional, and MEASUREMENT ONLY - it changes no control behaviour whats'
|
||||
option-desc 4172d9920d65 # en.yaml over 30 words (128); capitals: MEASUREMENT ONLY :: 'Optional, and MEASUREMENT ONLY - it changes no control behaviour whats'
|
||||
option-desc 09ceba2c6afb # en.yaml over 30 words (70); banned: clamp; capitals: MEASUREMENT ONLY :: 'Optional, MEASUREMENT ONLY. Some sensors - typically a kWh meter or a '
|
||||
option-desc 42a7eaac6ff1 # en.yaml banned: saturated :: 'How many consecutive saturated cycles before the loop stops winding up'
|
||||
@@ -133,7 +127,6 @@ option-name 52d03808da01 # en.yaml over 6 words (8) :: 'Your own INJECTION form
|
||||
option-name bf22f2121af4 # en.yaml over 6 words (8) :: 'Your own tariff formula (one line of JSON)'
|
||||
option-name 5593992fcf5b # en.yaml over 6 words (7) :: 'How far ahead to fetch prices (hours)'
|
||||
option-name d9fee5514a4b # en.yaml over 6 words (11) :: 'Levies and VAT by time of day (one line of JSON)'
|
||||
option-name 7d8d691905e0 # en.yaml over 6 words (7) :: 'PV production entities, one per inverter (W)'
|
||||
option-name eac7ee084aaa # en.yaml banned: Saturated :: 'Saturated cycles before freezing (count)'
|
||||
option-name 5c6bbc5cab40 # en.yaml banned: Saturation :: 'Saturation threshold (W)'
|
||||
option-name 99a1ec154d36 # en.yaml over 6 words (7) :: 'Shadow mode — run every decision, command nothing'
|
||||
@@ -179,29 +172,3 @@ refusal c4a1d0371e31 # validate.py over 30 words (42); capitals: THE DEVICE WIN
|
||||
refusal a15624d1aa10 # validate.py over 30 words (33); capitals: THE DEVICE WINS :: 'max_w is {max_w} W, so this controller may command {-max_w} W, but {op'
|
||||
refusal 26d0602c32d7 # validate.py over 30 words (79); capitals: THE FIRMWARE WINS :: 'meter_max_age_s is {max_age_s} s but the ESP32 firmware vetoes any P1 '
|
||||
refusal 2ade09aaa579 # validate.py over 30 words (73); banned: SAFETY-02, arbiter, watchdog :: 'sign_disagree_w is {sign_w} W but max_w{where} is {weakest} W, so the '
|
||||
row c24ab8bd9cb3 # main.py over 15 words (18); banned: heartbeat, layer 1; capitals: NO PASS FOR :: 'control loop: NO PASS FOR {_pass_age} s (layer 1 zeroes the inverter a'
|
||||
row c771d4bc1e0a # main.py over 15 words (17); banned: telegrams :: "P1 meter ({o.get('meter_source')}): {self.p1.net_w} W, {age} s old, {s"
|
||||
row f6195fee8575 # main.py over 15 words (33); capitals: METER MAY BE FROZEN :: 'METER MAY BE FROZEN - {…}. The loop is STILL FOLLOWING it and is still'
|
||||
row db05be7cd99c # main.py over 15 words (16); option key: meter_source; capitals: NOT COVERED :: "freeze detector: NOT COVERED on meter_source {o.get('meter_source')} -"
|
||||
row 9a21960bbbe8 # main.py capitals: NOT COVERED :: 'freeze detector: NOT COVERED - {…}'
|
||||
row c38b746a6585 # main.py banned: SATURATED; capitals: PEAK GUARD SATURATED :: 'PEAK GUARD SATURATED - {…}'
|
||||
row dd0629834473 # main.py over 15 words (36); banned: SAFETY-25; option key: peak_soc_floor; capitals: THE PEAK GUARD ONLY :: '{…}. NOTE: peak_soc_floor bounds THE PEAK GUARD ONLY - it is not a pac'
|
||||
row 4132e246e675 # main.py over 15 words (26); banned: telegrams; option key: meter_source; capitals: NOT COVERED :: "peak guard: NOT COVERED on meter_source {o.get('meter_source')} - the "
|
||||
row 7b34b16d8bb2 # main.py over 15 words (61) :: '{label}: no usable value this cycle from {entity} - and this row canno'
|
||||
row 04e0381f16c2 # main.py banned: CLAMP; capitals: OUTPUT CLAMP ENGAGED :: 'OUTPUT CLAMP ENGAGED - {…} Engagements: {self.clamp_wd.engagements}.'
|
||||
row 9f8b8adcbc6c # main.py banned: INTEGRATOR; capitals: LOOP AT INTEGRATOR BOUND :: 'LOOP AT INTEGRATOR BOUND - {…} Engagements: {self.clamp_wd.engagements'
|
||||
row f00cc9688eca # main.py over 15 words (20); banned: clamp :: 'output clamp: not engaged now, but it has engaged {self.clamp_wd.engag'
|
||||
row a44333431331 # main.py over 15 words (31); capitals: SIGN-DISAGREEMENT FAILSAFEX :: 'SIGN-DISAGREEMENT FAILSAFE{tag} - {…}. The inverter is held at 0 W. Fi'
|
||||
row 3ef4e60f2328 # main.py over 15 words (17) :: 'sign watchdog{tag}: armed{vs} (trips after {inv.sign_wd.cfg.hold_s} s '
|
||||
row 9f879b339282 # main.py over 15 words (50); banned: integrator; capitals: SITE SIGN-DISAGREEMENT FAILSAFE :: 'SITE SIGN-DISAGREEMENT FAILSAFE - {…}. EVERY inverter is held at 0 W. '
|
||||
row 96e93e34bdbf # main.py over 15 words (24); banned: watchdog :: 'site sign watchdog: armed against the sum of the commands (trips after'
|
||||
row 9ee8d293fea5 # main.py over 15 words (38); capitals: CIRCULATING POWER :: 'CIRCULATING POWER - {…}. EVERY inverter is held at 0 W. The meter cann'
|
||||
row 55eb950acd5f # main.py over 15 words (17); banned: watchdog :: 'circulation watchdog: armed (trips after {self.circ_wd.cfg.hold_s} s o'
|
||||
row 1817192a7f1c # main.py over 15 words (42); capitals: NOT DELIVERINGX :: 'NOT DELIVERING{tag} - {…}. Nothing has been commanded differently and '
|
||||
row 685c1416364b # main.py over 15 words (26) :: 'delivery watchdog{tag}: armed (reports after {inv.delivery_wd.cfg.hold'
|
||||
row d3cd52827dd0 # main.py over 15 words (29); banned: watchdog :: 'delivery watchdog: n/a at one inverter - a unit short of its share is '
|
||||
row d6981c8d7b56 # main.py banned: latched :: 'no e-stop fitted: if this host dies the battery stays latched at its l'
|
||||
row 685c8f02c97a # main.py capitals: NO SITE TOTAL :: 'PV production: NO SITE TOTAL - {…}. Reporting: {…}'
|
||||
row abef339bf192 # main.py over 15 words (25); option key: pv_entities :: 'PV production: `pv_entities` is set, so `pv_entity` is IGNORED - the {'
|
||||
row 514511bd0a93 # main.py over 15 words (32); option key: pv_invert_entities :: 'PV production: {ent} reads {watt} W - far below zero, so its sign is p'
|
||||
row 328abd6171ce # main.py over 15 words (22); option key: pv_invert_entities :: 'PV production: `pv_invert_entities` names {ent}, which is not a PV ent'
|
||||
|
||||
Reference in New Issue