Compare commits

..
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5.5 e9fa11e60d Release 0.20.0 review: CHANGELOG wording (OPT-23 headline, CI-15 time, UX-75 quote)
checks / unit (pull_request) Successful in 19m14s
infra-pin / fresh (pull_request) Successful in 1s
- The OPT-23 headline said a daily-total forecast is now counted right by
  day; OPT-30 (known issue) still over-counts by day. Say what changed.
- CI-15: 16 min was one run; runs took 16 to 24 min.
- UX-75: quote the page text as it reads.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-01 17:02:17 +01:00
glenn schrooyenandClaude d2f63fe86a Release 0.20.0: version bump and CHANGELOG
checks / unit (pull_request) Successful in 24m4s
infra-pin / fresh (pull_request) Successful in 2s
config.yaml version 0.20.0 (minor; no option change) and a ## 0.20.0
CHANGELOG section that folds in the unreleased block and lists every
first-parent merge since 0.19.2 (f1c9733).

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-01 16:12:45 +01:00
admin cdafa2c189 Merge pull request 'OPT-34 fix (rig F-1): a replaced evening forecast does not come back' (#225) from OPT-34-fix into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-01 14:21:44 +01:00
2 changed files with 111 additions and 7 deletions
+110 -6
View File
@@ -1,13 +1,117 @@
# Changelog
## 0.20.0
**A minor bump: a Forecast tab, a night grid charge sized to what the sun will not give, a kept evening forecast, and no option changes.**
No option was added, removed or renamed, and no default changed (86 options). It is a minor bump because Leftover solar now buys different amounts from the grid and the night charge keeps its level when the forecast goes quiet; every saved setting still starts.
**Existing installs need no option change:** options that start 0.19.2 also
start 0.20.0. The changes below apply with one inverter or two.
**A Forecast tab.** A new tab next to Home and Batteries shows today and tomorrow hour by hour: the solar forecast, the sun measured so far, the house's expected use, and each battery's level with its planned charge and give blocks. It shows what the add-on plans and changes no command.
**Leftover solar buys what the sun will not give.** On a day/night tariff the night grid charge now covers the expensive hours' use less the sun counted for them, where it used to buy for the whole day. A forecast with only a daily total, such as Forecast.Solar, is no longer counted several times over by day, so Leftover solar no longer charges too little because of it.
**The evening forecast is kept for the night.** Forecast.Solar-type sensors stop updating in the evening. The last fresh reading is now kept until 06:00, so the night cheap run is judged with the forecast's price gap and Leftover solar still plans its charge. A newer reading replaces it at once, and a charge that is running keeps its planned level if the figure ends.
**No false peak alarm during the night grid charge.** "Battery stopped limiting the peak", and its notification, no longer appear while the 15-minute period stays within 10 W of the aim.
Contents of this release, in merge order since 0.19.2 (`f1c9733`):
| | |
|---|---|
| `a1d0703` | Home now draws a grid charge only where the add-on will take it, with battery modes on or off; before, it could show the rest of a refused cheap run, or a charge after the last dear period. The price texts say "lowest price left" and "highest price left", and no command changes ([[UX-53]], #209) |
| `f5afb42` | The day planner's hour loop now always ends on the night the clocks go forward. Without time-zone data it could go round forever and freeze the add-on; the add-on's own image has that data ([[SAFETY-123]], #211) |
| `4a1f6cc` | A new Forecast tab shows today and tomorrow hour by hour: the sun, the house and each battery's level, with the charge and give blocks Home would draw. It shows the plan and changes no command; notes say when a part is not known yet ([[UX-54]], #210) |
| `6be7e41` | The add-on's test files now run six at a time in the checks, so a check takes about 15 to 25 minutes, where one by one it ran past an hour. No change in behaviour ([[CI-15]], #215) |
| `b6be312` | The day plan counts the sun right: a forecast with only a daily total is no longer counted several times over. On a day/night tariff the night charge for Leftover solar covers the expensive hours' use less the sun counted for them, shared between batteries by capacity, and the screens say when another battery or the grid covers the rest ([[OPT-23]], [[OPT-28]], #218) |
| `cc9bbeb` | When a solar forecast sensor stops updating in the evening, the night plan uses its last fresh reading, for the day it is for only. One missed reading no longer drops the forecast at once, and the pages say when a figure is kept ([[OPT-27]], #219) |
| `deee98d` | The night grid charge under the peak limit no longer raises a false "Battery stopped limiting the peak" alarm when the 15-minute period stays within 10 W of the aim. A real overrun still alarms; a steadily rising load alarms a little later, and with a peak margin under 10 W a period can end up to 10 W over the limit without it ([[SAFETY-126]], #221) |
| `8afadbd`, `cdafa2c` | The kept evening figure now counts until 06:00, not until 03:00, and a charge that is running keeps its planned level when the figure ends. A newer reading replaces the evening figure at once and for good, so it does not come back later in the night ([[OPT-34]], #222, with its fix #225) |
| `d4c01da` | Comments and docstrings in the peak guard and the price files were cut to a line and a pointer to the decision notes. No change in behaviour: a check shows the code itself is the same ([[MAINT-20]] part 1, #223) |
The merge that brought 0.19.1 and 0.19.2 into this branch (`f1b7244`, #220) adds nothing else; the Forecast tab uses the same price gap as control since it.
### Known issues
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
- A battery whose reading at rest is beyond about ±175 W is still not caught when it refuses ([[SAFETY-97]]).
- The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s. This is about the guard's discharge only; a grid charge is cut back since 0.19.2 ([[SAFETY-99]]).
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
- Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]).
- Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]).
- Two inverters: when a battery drops out during a solar surplus, the others can swing by up to 1.5 kW in a simulation ([[SAFETY-105]]).
- Two inverters: after a drain ends, a change in house use can go unanswered for about 9 s, because some readings are old ([[SAFETY-106]]).
- Two inverters: when one battery's level is missing, both batteries are held at 0 W, and for about 15 s the last command stays on ([[SAFETY-108]]).
- Two inverters: if one battery's level stays missing for 12 h, the other battery's cycle can be marked failed, with a 7-day wait and a notice, though it is healthy. This comes from reading the code; it has not been seen on a site ([[MAINT-17]]).
- When the 15-minute demand forecast sensor counts the battery's own charge, the maintenance charge runs at about half the power the peak limit leaves, so it takes about twice as long. Seen on a site: about 1.2 kW instead of 2.5 kW, and the peak limit was kept ([[SAFETY-111]]).
- One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]).
- After a Home Assistant restart, control still waits until Home Assistant has finished starting, which can take several minutes, though the readings are already there ([[SAFETY-115]]).
- While Home Assistant is not answering, the page can list inverters as refusing commands and sensors as missing, and send you to Developer Tools, though they are fine ([[UX-37]]).
- If Home Assistant hangs or stops, the page keeps saying "Waiting for Home Assistant" and never turns into an alarm ([[SAFETY-113]]).
- Right after Home Assistant has started, the page can say for about 4 s that an inverter cannot be controlled, and the first command can come late ([[SAFETY-114]]).
- After a Home Assistant restart, the controller status sensor can still say "running" while the add-on cannot control. It was seen once, and the cause is not known ([[SAFETY-116]]).
- Battery modes on: after a planned top-up from the grid, the Batteries screen can say "Enough sun is forecast" ([[UX-32]]).
- Battery modes on: the forecast line "we count on" can show more sun than the plan counts, because the plan takes house use off first ([[UX-33]]).
- Battery modes on: before a planned top-up, the Today list shows a smaller "gives" amount than the plan will use; it grows as the charge happens ([[UX-34]]).
- Two inverters, battery modes on: while the other battery is in its maintenance charge, a battery's card can say it charges from the grid while it stays at 0 W ([[OPT-18]]).
- Two inverters, battery modes on: while a battery refuses to charge in a cheap run, the action log on the page gets about 8 lines an hour for its retries, and the page hint says "waiting for a better price" ([[UX-38]]).
- A battery in a safety stop, or one the add-on cannot reach, can still be started for a cycle, and its drain then waits about 12 h and ends in a failed-cycle notice. This comes from reading the code; it has not been seen on a site ([[MAINT-19]]).
- On the Settings page, the rows of the solar forecast lists are labelled "Phase 1", "Phase 2" instead of "Sensor 1", "Sensor 2" ([[UX-27]]).
- In the solar forecast list, a blank or repeated row makes "source 2 of 2" count differently from the rows on the Settings page ([[UX-28]]).
- The solar forecast message says "has no reading" also when the sensor shows a number that is too old or in the wrong unit ([[UX-29]]).
- If you use only the forecast lists, two Settings notes sit on the single-sensor field, and one of them tells you to set that field ([[UX-30]]).
- After a restart during a price outage, the "No prices" message can say "yet" when prices did come in earlier ([[UX-39]]).
- On the new settings page, you cannot see whether a price service token is set. Check the Configuration tab ([[UX-41]]).
- On the classic settings page, the first click on Save after editing a field can do nothing. Click again ([[UX-42]]).
- A steady overload on a 1 s meter can warn, and send the Home Assistant notification, 2 or 3 times at the start of each 15-minute period instead of once. The peak limit is still kept ([[SAFETY-122]]).
- A fixed tariff is priced once per hour, so a price window that starts or ends at :15, :30 or :45 gets the wrong price for part of that hour. Windows that start and end on the hour are right ([[TARIFF-23]]).
- Step 6 of the setup wizard stays empty because of an error in the page, in English and in Dutch ([[UX-51]]).
- On Dutch pages, refusal texts, the last-event line under the Home buttons, the installer details and the trading status sentences are still English, and a few Dutch texts read badly, such as "1 metingen geweigerd" ([[UX-52]]).
- Some price texts say "hour" where the add-on acts on a 15-minute period, such as "cheapest hour" ([[UX-47]]).
- After the add-on restarts, the Home price chart shows no price for the earlier part of today, and the setup check can say "12 of 24 hours", though the prices are known ([[UX-48]]).
- With battery modes on and only batteries on "Leftover solar", the Home price chart can mark a cheap period where no battery charges ([[UX-49]]).
- On a phone, the bars of the Home price chart are too thin to tap one 15-minute period. The arrow keys work ([[UX-50]]).
- Control acts on Home Assistant readings that arrive late. With readings 10 s behind, the give run can swing and send up to 1.9 kW to the grid for about 50 s in a rig test; with readings 30 s behind, a battery can charge from the grid in an expensive period. Also in 0.19.2 ([[SAFETY-128]]).
- In the last second of a 15-minute period, being a few watts over the aim can make the peak guard ask a battery for full power for one second. When a charge ends on a period edge, the last-second give can fade out over about 10 s, and a rig test exported up to 7.4 kW for about 8 s ([[SAFETY-124]]).
- During the night grid charge, a 15-minute period can end 6 to 14 W over the peak aim, because the battery charges harder than asked. This was seen in simulation; a rig test saw 2 to 8 W ([[OPT-35]]).
- The test rig could not bring back the false peak alarm that [[SAFETY-126]] fixes, so that fix is shown in simulation only. Watch the notifications for a few nights ([[TEST-35]]).
- The night cheap run is sized for the batteries' full charging power, not for what the peak limit leaves. Under a tight limit the run can end before the batteries reach their level, and Home can show a level they do not reach (79.9 % against a shown 95 % in a rig test) ([[OPT-25]]).
- By day, a Leftover solar plan that has only a daily forecast figure counts the sun from now, not from when the figure was read. It counts about 22 % too much for a figure one hour old; the night plan is not affected ([[OPT-30]]).
- The night charge can buy too much in a house that uses more at night than by day, such as one with a car charger or heat pump, and on a sunny day, because spare sun in one expensive hour does not count for the later ones ([[OPT-31]]).
- A cheap run that has already started can overlap a new give run after a re-plan, so a battery can charge from the grid at the dearest price for part of an hour. This was seen in a test case, not on a site. Also in 0.19.2 ([[OPT-32]]).
- If the solar forecast sensors stop updating before 17:00, as in winter or further north, there is no forecast from three hours after their last update until 20:00 ([[OPT-33]]).
- With a forecast that gives only a daily total, the sun is spread an hour off on the two clock-change days after the change. The day's total is right ([[OPT-24]]).
- The add-on learns the house's use only once a solar forecast is set, so a site that adds a forecast later waits one more day for its first plan ([[OPT-26]]).
- Home says "No trading on price yet: no prices have arrived" when every battery is on Solar first, though the prices are shown ([[UX-55]]).
- The Home plan header can say "Charges in the cheapest hour, gives power in the dearest" when Home draws no charge, and it says "hour" for 15-minute prices ([[UX-56]]).
- While the peak guard holds back charging, Home hides the rest of the cheap run and gives no reason. The charge starts again when the guard lets go ([[UX-57]]).
- With battery modes on and selling on, Home can draw a "Sells up to" block when the add-on judges the trade not worth it, and then it will not sell ([[UX-58]]).
- Home, the plan and the Forecast tab stop drawing a battery's give at the trading floor, though control goes on giving down to the battery's cut-out ([[UX-59]]).
- During a price outage, the Batteries screen says "Prices differ too little" and Home says "The price gap is too small" ([[UX-60]]).
- With battery modes on and no meter, or a meter that is a Home Assistant entity, a grid charge is not possible and nothing says so ([[UX-61]]).
- On the Batteries screen, a charge the add-on refused in a cheap run reads as "Saves its power for ...", for up to 15 minutes ([[UX-62]]).
- A Leftover solar battery with no capacity set never charges from the grid when a solar forecast is set, and nothing warns about it ([[UX-63]]).
- The "How the modes work" box on the Batteries screen does not describe Cheap hours only ([[UX-64]]).
- With battery modes on, Settings still shows "Trade on the price spread", which the modes ignore. A site with modes on and no price source starts, and the Batteries screen says "No prices, so it follows the house" without pointing to Settings ([[UX-65]]).
- With battery modes off and several equal prices in a row, Home and the Forecast tab draw one price quarter, while the add-on trades every quarter of the run ([[UX-67]]).
- Late in the day, the Forecast tab's "now" line and last bars sit over the axis labels at the right edge ([[UX-68]]).
- The Forecast tab's level curve charges at each battery's full rating. Under a peak limit the levels it draws are too high and a charge block can end early (54.6 % shown against 39.7 % in a rig test) ([[UX-70]]).
- The peak forecast check says maintenance charging is not kept under the peak limit when no peak forecast is set, but since 0.19.2 it is ([[UX-73]]).
- The peak guard row can show the same figure twice, such as "at this rate 3 500 W, over 3 500 W". Also in 0.19.2 ([[UX-74]]).
- If the inverter's setpoint entity appears in Home Assistant after the add-on has started, the page keeps saying "Inverter control: not found in Home Assistant" and the batteries say "An alarm stopped control" until a restart, though control runs ([[UX-75]]).
### If you are crossing from a version older than 0.10.0
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
bare options (`jq '.data.options'`) first.
## 0.19.2
### Not in a release yet
- The night grid charge no longer raises "Battery stopped limiting the peak" when the 15-minute period stays on the aim. A steadily rising load now alarms a little later, and with a peak margin of 0 a period can end up to 10 W over the limit without this alarm ([[SAFETY-126]]).
- A night grid charge for *Leftover solar* no longer stops at 03:00 when the solar forecast sensors went quiet in the evening. The evening's figure is used until 06:00, unless a newer reading has replaced it that night, and a charge that has started goes on to its level ([[OPT-34]]).
**A patch bump: two fixes, one for charging from the grid under the peak limit and one for the night charge of Leftover solar, and no option changes.**
**A patch bump: one fix for charging from the grid under the peak limit, and no option changes.**
No option was added, removed or renamed, and no default changed (86 options).
**Existing installs need no option change:** options that start 0.19.1 also
start 0.19.2. The change below applies with one inverter or two.
+1 -1
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller
version: "0.19.2"
version: "0.20.0"
slug: goodwe_controller
description: >-
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port by sending it a