@@ -1,5 +1,49 @@
|
||||
# Changelog
|
||||
|
||||
## 0.17.0
|
||||
|
||||
**A minor bump: changed behaviour, and no option changes.** No option was
|
||||
added, removed or renamed, and no default changed (83 options). Options you
|
||||
saved work as before. The changes below apply with one inverter or two, unless
|
||||
a line says "Two inverters".
|
||||
|
||||
**Maintenance with no battery level.** When the battery level is missing,
|
||||
battery maintenance now ends on its own time limits instead of waiting for the
|
||||
level to come back (MAINT-14, MAINT-15). You do not need to change any option.
|
||||
|
||||
Contents of this release, in merge order since 0.16.0 (`451729c`):
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `b527e99` | Two inverters: after a drain ends, the other battery no longer swings on old readings. In the test, it held steady for 23 s where 0.16.0 moved it by 720 W ([[SAFETY-103]]) |
|
||||
| `8a17711` | A full battery that stops at 98 or 99 % no longer counts as a failed charge. After 60 min with no new high, the charge counts as done; a charge that truly fails now waits 7 days and shows one notice ([[MAINT-13]]) |
|
||||
| `bf3ac79` | With no battery level, a maintenance charge still ends at its time limit and a drain waits at 0 W. The log no longer repeats a line every second ([[MAINT-14]]) |
|
||||
| `db9e231` | One inverter: when maintenance charges a battery that is already full, the log no longer repeats "The battery refuses to give power" every second. In the test, 1 line in 16 min where the code before this fix wrote about 1,700 in 15 min; the power does not change ([[SAFETY-107]]) |
|
||||
| `580c200` | The balancing hold after a charge now ends on time when the battery level is missing. Before, it waited until the level came back ([[MAINT-15]]) |
|
||||
|
||||
### Known issues
|
||||
|
||||
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
|
||||
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
|
||||
- A battery whose reading at rest is beyond about ±175 W is still not caught when it refuses ([[SAFETY-97]]).
|
||||
- The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s ([[SAFETY-99]]).
|
||||
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
|
||||
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
|
||||
- Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]).
|
||||
- Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]).
|
||||
- Two inverters: when a battery drops out during a solar surplus, the others can swing by up to 1.5 kW in a simulation ([[SAFETY-105]]).
|
||||
- Two inverters: after a drain ends, a change in house use can go unanswered for about 9 s, because some readings are old ([[SAFETY-106]]).
|
||||
- Two inverters: when one battery's level is missing, both batteries are held at 0 W, and for about 15 s the last command stays on ([[SAFETY-108]]).
|
||||
- Two inverters: if one battery's level stays missing for 12 h, the other battery's cycle can be marked failed, with a 7-day wait and a notice, though it is healthy. This comes from reading the code; it has not been seen on a site ([[MAINT-17]]).
|
||||
- One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]).
|
||||
|
||||
### If you are crossing from a version older than 0.10.0
|
||||
|
||||
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
|
||||
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
|
||||
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
|
||||
bare options (`jq '.data.options'`) first.
|
||||
|
||||
## 0.16.0
|
||||
|
||||
**A minor bump: changed behaviour, no option added or removed, and one default
|
||||
|
||||
@@ -58,10 +58,7 @@ allows discharge.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- **HOLD with no SoC** still holds 0 W and, as before, does not end while the
|
||||
reading is missing: its time check sits behind the same early return. A HOLD
|
||||
needs no level to end, so this is a candidate follow-up, not part of this fix. It is card MAINT-15. The "no battery level" line in
|
||||
HOLD says only that the hold waits for the level.
|
||||
- **HOLD with no SoC**: closed by MAINT-15 (`MAINT-15-hold-ends-without-soc.md`).
|
||||
- It does not tell the operator why the reading is missing (sensor, register,
|
||||
link). It does not reuse the stale-input gate; it is the cycle's own rule.
|
||||
- The charge itself is still driven by the control loop, which has its own
|
||||
|
||||
@@ -0,0 +1,47 @@
|
||||
# MAINT-15 - the balancing hold ends on time with no SoC reading
|
||||
|
||||
**Status: for review.** Tests: `test_maint15.py`. No option added.
|
||||
|
||||
**The fault.** `step()` sent every tick with no SoC to `_no_soc()`, and for
|
||||
HOLD that returned 0 W without the time check. A hold that lost its reading
|
||||
never ended: `last_completed` was never written and the next due date never
|
||||
moved. Harmless for power (0 W), but the cycle was stuck. This was left open
|
||||
in MAINT-14.
|
||||
|
||||
## Rule
|
||||
|
||||
1. **HOLD ends at `hold_min` whether or not there is a reading.** One helper,
|
||||
`Maintenance._hold()`, holds the time check and is used by both paths. When
|
||||
the time is up it writes `last_completed`, goes IDLE and logs the same
|
||||
"cycle COMPLETE" line. Before the time is up it commands 0 W as before.
|
||||
2. **Text.** The 15-min "no battery level" line in HOLD now reads "The hold
|
||||
still ends at its normal time." Still once per episode.
|
||||
|
||||
## Why
|
||||
|
||||
HOLD is reached only after the charge counted as done. Every entry into HOLD
|
||||
is in `step()` or `_no_soc()` and follows a charge that reached the target,
|
||||
stalled near full (MAINT-13) or timed out near full (MAINT-13/14). Nothing else
|
||||
sets the phase to HOLD (`_enter(HOLD` has four call sites, all after a done
|
||||
charge). The hold is a wait for the BMS to balance; it never needed the level.
|
||||
So a hold that ends with no reading is a completed cycle. The "cycle COMPLETE"
|
||||
line is true without a reading: it names minutes of hold, not a level.
|
||||
|
||||
## Cost
|
||||
|
||||
- If the level was lost during the hold, the cycle is recorded as complete
|
||||
without anyone seeing the final level. The charge had counted as done, so this
|
||||
is the same trust MAINT-14 already gives a charge that ends with no reading.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- It does not check that the pack is still full at the end of the hold.
|
||||
- It does not say why the reading was lost.
|
||||
- With a reading, nothing changes. `test_maint15.py` section 7 compares the new
|
||||
HOLD tick by tick with a frozen copy of the release/1.0 HOLD branch (phase,
|
||||
setpoint, owner, events, `last_completed`) at four `hold_min` values. A wider
|
||||
trace of the whole cycle (800 seeded runs against db9e231) was run outside the
|
||||
repo; its script and log are kept under `scratch/MAINT-15/` of the dev
|
||||
workspace, not in this repository.
|
||||
- A state file written by an older version with `phase: hold` loads and ends on
|
||||
time; the file is not changed in format.
|
||||
@@ -0,0 +1,79 @@
|
||||
# OPT-17 - the solar forecast from several entities, summed
|
||||
|
||||
**Status: for review.** Tests: `test_opt17.py`. Two options added.
|
||||
|
||||
A site whose forecast comes as several Home Assistant sensors (one per
|
||||
inverter or roof side) had to build a template sensor to sum them. Now each
|
||||
day can list them.
|
||||
|
||||
## Options
|
||||
|
||||
- `pv_forecast_entities` and `pv_forecast_tomorrow_entities`: lists of
|
||||
sensors, default `[]`, the same shape as `pv_entities`.
|
||||
- `pv_forecast_entity` and `pv_forecast_tomorrow_entity` are unchanged. An
|
||||
install that uses them needs no edit.
|
||||
- **Why new keys, not "string or list" in the old ones.** Measured on
|
||||
Supervisor 2026.08.0 by `tools/supervisor_shape_probe.py` §J, as TEL-12's
|
||||
§G did for `pv_entity`. Declared as a list, each forecast key refuses the
|
||||
string an install already stores (`Invalid list for option
|
||||
'pv_forecast_entity'`), and a `[]` default does not rescue it. The one
|
||||
spelling that takes both, `match(.*)?`, also takes the integer 417 and
|
||||
shows a plain text box, so a second sensor cannot be added in the UI.
|
||||
- §J also shows: a 0.17.0 blob validates unchanged with the lists at `[]`;
|
||||
the lists render as repeatable fields; a downgrade drops them and keeps
|
||||
the single keys.
|
||||
- `[]` in `options:` is load-bearing, as for `pv_entities`.
|
||||
|
||||
## Rules
|
||||
|
||||
1. **One key per day.** Setting the single key and the list for the same day
|
||||
is refused at start, with one message: keep the list, clear the single one.
|
||||
The list can hold that entity too. (TEL-12 lets `pv_entities` replace
|
||||
`pv_entity` with a caution row. Here the brief asked for a refusal: a
|
||||
doubled or dropped forecast changes what a battery buys, and no install
|
||||
has both keys yet, so the refusal breaks nothing.)
|
||||
2. **Each member in its own unit.** Every member is read as one forecast
|
||||
sensor is today (`solarfc._day()`): Wh, kWh or MWh, never guessed. Then the
|
||||
day's kWh are added up. A repeated id counts once.
|
||||
3. **One member not usable means the day is not usable.** Missing,
|
||||
unavailable, unknown, stale, not an energy unit, or a bad number: that
|
||||
day's sum is not used, exactly as when the single sensor reads that way.
|
||||
No today means no forecast (P3 option A). No tomorrow means today only.
|
||||
4. **Hourly split.** If every member has a split, the splits are joined
|
||||
(overlapping periods add up). If any member has none, the sum is spread
|
||||
over the bell, as for a state-only sensor.
|
||||
5. **Time.** The forecast is as old as its oldest member.
|
||||
6. **One read.** All members of both days are read in one gather, inside the
|
||||
gather that reads the inverters, so a slow sensor does not delay control.
|
||||
7. **Shown and logged once.** With two or more members, each one not usable
|
||||
is named on the status page by its place in the list (STYLE.md: no entity
|
||||
ids on the page), as a caution row titled "Solar forecast" on Home. The
|
||||
action log names the entity id, once when the set of failing members
|
||||
changes.
|
||||
8. **One member is the single key.** A one-member list reads, plans, shows
|
||||
and logs exactly as the single key with that entity.
|
||||
|
||||
## Why
|
||||
|
||||
- A partial sum is a smaller number that looks real. Two of three inverters'
|
||||
forecasts read as a duller day, and Leftover solar would then buy grid
|
||||
energy the sun was going to give. TEL-12 took the same rule for the same
|
||||
reason. No forecast is a known state with a tested fallback.
|
||||
- The bell for a mixed list: joining one member's hours with another's total
|
||||
has no honest shape, and the bell is the existing state-only rule.
|
||||
|
||||
## Cost
|
||||
|
||||
- One flaky member costs the whole day's forecast. A site with three
|
||||
sensors loses the plan more often than one with a template sum that hides
|
||||
gaps.
|
||||
- Two more options (85).
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- No weighting or calibration per member; FCST-01 is still the own forecast.
|
||||
- Members on different integrations with different refresh times: each must
|
||||
be fresh (3 h) on its own; there is no wait for a lagging one.
|
||||
- The day plan itself, the trust and the house profile are unchanged.
|
||||
- The Batteries screen still says only "no solar forecast now". The member
|
||||
is named on the status page.
|
||||
@@ -0,0 +1,96 @@
|
||||
# SAFETY-107 - a refusal held under another writer is learned once
|
||||
|
||||
**Status: for review.** Tests: `test_safety107.py`. One inverter only; nothing
|
||||
changes at N>1 (SAFETY-73's unit refusal has no "another writer" end).
|
||||
|
||||
**The defect** (MAINT-13 F5, MAINT-14 "seen again"). A full pack under a
|
||||
maintenance charge in a cheap window takes no charge. At N=1 the action log then
|
||||
showed "BATTERY REFUSES asked -2500 W ..." and "BATTERY REFUSES ENDED: another
|
||||
writer" every cycle: 548 + 548 lines in 15 min on the MAINT-13 rig head,
|
||||
652 + 651 in 12 min on its base, 33 + 32 in 60 s in MAINT-14's c2b. The 40-line
|
||||
log flooded and the hint under the buttons changed every second, so the
|
||||
MAINT-13 notice was gone at once.
|
||||
|
||||
**Cause** (`main.py`, the SAFETY-52 block before `compute()`). The end tested
|
||||
`self.target != self.loop_w`: the wire differs from the loop's ask. A held
|
||||
refusal makes the loop ask 0 W, so any claim that binds (the maintenance
|
||||
charge's `hi`, the peak guard's `lo`, a trade's SET) differs from it on every
|
||||
cycle. The refusal was ended against the same writer it had been learned
|
||||
against. `sat_count` is not reset by that end, so `compute()` learned the same
|
||||
refusal again in the same cycle. Nothing about the battery or the wire had
|
||||
changed; only the log and the hint did.
|
||||
|
||||
**Other writers.** The same flap comes from any writer that holds the wire
|
||||
while the loop is refused, as long as the evidence lasts: a trade (a SET at
|
||||
P_ARBITRAGE) into a full pack, and the peak guard over an empty pack: 335
|
||||
refusal lines in 15 min each at a 5 s meter (`test_safety107.py` part 2, run on
|
||||
release/1.0).
|
||||
A maintenance drain or hold does not flap: its SET resets `sat_count` each cycle.
|
||||
|
||||
**The rule** (`_refusal_update()`, `rejudged`). When another writer held the
|
||||
wire, the held refusal is judged afresh: `compute()` gets `refused=0` and no
|
||||
probe, exactly as before the change. Then:
|
||||
|
||||
1. it finds the same refusal against that writer's ask: the same episode
|
||||
continues, with no line and no hint. The probe clock restarts, as it did on
|
||||
the old end and start: a probe is the loop's ask, and it is not on the wire
|
||||
while another writer is;
|
||||
2. it does not: the refusal ends, logged "another writer", or "the battery
|
||||
gives power" when the reading shows it (it was "another writer" before);
|
||||
3. it finds the other direction: end, then a new start, as before. In
|
||||
practice 2 comes first: SAFETY-94's evidence restarts when the ask changes
|
||||
sign, so a writer that turns round ends the refusal at once and the other
|
||||
way is learned ~12 cycles later (`test_safety107.py` part 3e).
|
||||
|
||||
**Why this rule.** The end now means what SAFETY-52 meant by it: the refusal no
|
||||
longer describes what is on the wire, judged by the same test that learns it.
|
||||
`compute()` sees the same inputs as before and the state after each cycle is
|
||||
the same (`batt_refused`, `batt_refused_at`), so every command is unchanged.
|
||||
Keeping the held refusal into `compute()` instead (mutation M5) would also
|
||||
stop the lines, but it holds the loop at 0 W where the old law let it ask past
|
||||
a writer's limit, which changes commands; it also removes SAFETY-52's
|
||||
owner-decided "another writer" exit.
|
||||
|
||||
**Evidence.**
|
||||
- Differential trace (`goodwe/scratch/SAFETY-107/probe/trace.py`, not in this
|
||||
repo; the real Controller in the CI image, release/1.0 bf3ac79 against this
|
||||
tree): 300 seeds, N=1 (153) and
|
||||
N=2 (147), 1/2/5 s meter, full/empty/dead/healthy battery windows, a stepping
|
||||
house, maintenance charge with the cheap window opening and closing, P1 and
|
||||
the peak guard, trade windows, stop/start; 427 680 cycles, 294 seeds with a
|
||||
refusal held. Every command, site target, integrator, `sat_count`, refusal
|
||||
state and reason is identical. Refusal lines: 100 748 before, 2 188 after.
|
||||
- The card's case: 1 line in 15 min at N=1 and N=2, 1/2/5 s meter, house
|
||||
importing or exporting (release/1.0: 335-1 753 at N=1; N=2 was already 1).
|
||||
|
||||
**Mutations** (`tools/mutation_run.sh` on purged copies; reds in
|
||||
test_safety107 / test_refusal / test_refusal_units; trace = seeds of 300 whose
|
||||
commands differ from release/1.0):
|
||||
|
||||
| | mutation | reds | trace |
|
||||
|---|---|---|---|
|
||||
| M1 | `now == rejudged` -> `False` (every such cycle ends: the old flap) | 26 / 0 / 0 | 0 |
|
||||
| M2 | `rejudged` always 0 (another writer never ends it) | 5 / 1 / 2 | 29 |
|
||||
| M3 | the probe clock is not restarted on a continued episode | 1 / 0 / 0 | 2 |
|
||||
| M4 | a probe may open while rejudged | 0 / 0 / 0 | 0 |
|
||||
| M5 | the held refusal goes into `compute()` while rejudged | 2 / 1 / 2 | 27 |
|
||||
| M6 | an end while rejudged always says "another writer" | 1 / 0 / 0 | 0 |
|
||||
|
||||
M4 is equivalent: a probe matters only if `compute()` engages in that call,
|
||||
which needs `SETTLE_CYCLES` saturated against the writer, and each of those
|
||||
cycles restarted the clock. The line stays because it states the rule.
|
||||
|
||||
**Cost.** None in power. A takeover by a different writer while the battery
|
||||
still refuses is logged as an end and, ~12 cycles later, a new start against
|
||||
that writer (3 lines for the episode, `test_safety107.py` part 3a).
|
||||
|
||||
**Not covered.**
|
||||
- A perfectly flat reading under a writer. The stale-reading gate trips, stops
|
||||
the site and seeds the refusal (SAFETY-52 decision 3). After the stop the
|
||||
writer's ask returns fresh, `compute()` has no saturation history against it,
|
||||
so the refusal ends at the first cycle and the next trip seeds it again: 2
|
||||
lines per gate cycle (29 in 15 min, house exporting), the same as release/1.0.
|
||||
The gate cycle itself (0 W, then the writer's ask) is the cause; stopping it
|
||||
changes commands. None of the rig runs showed it: real readings move.
|
||||
- At N=1 a refusal shapes only the loop. A writer above it still asks the
|
||||
battery; at N>1 SAFETY-73's P_SAFETY claim binds every writer.
|
||||
@@ -0,0 +1,98 @@
|
||||
# SAFETY-112 - control waits for Home Assistant to finish starting
|
||||
|
||||
**Status: for review.** Tests: `test_safety112.py`, `test_messages.py`.
|
||||
Control is unchanged. The add-on now says plainly that it is waiting.
|
||||
|
||||
## Cause
|
||||
|
||||
The Supervisor's proxy refuses every add-on request with 502 until Core's
|
||||
state is `RUNNING`. The add-on reads every battery reading and writes every
|
||||
power request through that proxy, so it cannot control until then. Readings
|
||||
that are already live inside Home Assistant do not help.
|
||||
|
||||
Source, Supervisor 2026.08.0 (the image the live site ran at CFG-04):
|
||||
|
||||
- `supervisor/api/proxy.py`, `APIProxy.api()` (REST, used for reads and
|
||||
`number.set_value`) and `APIProxy.websocket()` both start with
|
||||
`if not await self.sys_homeassistant.api.check_api_state(): raise HTTPBadGateway`.
|
||||
- `supervisor/homeassistant/api.py`, `check_api_state()` returns
|
||||
`state.core_state == "RUNNING" or state.offline_db_migration`. The state
|
||||
comes from Core's `/api/core/state`.
|
||||
- Upstream `main` has the same gate in both handlers (read 2026-10-13).
|
||||
- A Core restart restarts only the Core container
|
||||
(`homeassistant/core.py`, `restart()`). The add-on keeps running.
|
||||
|
||||
The add-on itself has no wait. Nothing in `app/` reads Core's state or waits
|
||||
for an event. The loop reads its inputs every second, a 502 gives `None`,
|
||||
and missing inputs give 0 W. P1 backoff is not involved: the live site reads
|
||||
the meter straight from the HomeWizard (`homewizard_local`), not through Home
|
||||
Assistant.
|
||||
|
||||
## Measured
|
||||
|
||||
Repro stack `safety112-*`, all removed afterwards:
|
||||
|
||||
- Home Assistant 2026.9.4, as live.
|
||||
- A test integration whose `async_setup` sleeps, so Core stays `NOT_RUNNING`.
|
||||
- A fake meter and two fake inverters that update every 2 s from load.
|
||||
- The Supervisor's own `APIProxy` and `HomeAssistantAPI` from the 2026.08.0
|
||||
image. Only the add-on token lookup, Core's access token and the container
|
||||
check are stubbed.
|
||||
- The add-on on `meter_source: homewizard_local` against a fake HomeWizard.
|
||||
|
||||
Times are seconds after `docker restart` of Home Assistant:
|
||||
|
||||
| run | Core `NOT_RUNNING` | entities live in HA | Core `RUNNING` | proxy 502 | first write | wait from live readings |
|
||||
|---|---|---|---|---|---|---|
|
||||
| base 3050fa5, N=2 | 13.1 | 17.1 | 253.1 | 0.9-252.7 (1 132 requests) | 254.7 | 237.6 |
|
||||
| base 3050fa5, N=1 | 13.1 | 18.1 | 256.1 | 1.5-255.1 (573 requests) | 257.2 | 239.1 |
|
||||
| this change, N=2 | 12.2 | 17.2 | 313.2 | 1.4-312.5 (1 406 requests) | 317.6 | 300.4 |
|
||||
| this change, N=1 | 12.2 | 17.2 | 255.2 | 1.2-254.1 (571 requests) | 257.1 | 240.0 |
|
||||
|
||||
The first write comes 1.0-4.4 s after `RUNNING`, so the whole wait is the
|
||||
proxy's. With a 400 s sleep Core moved on at 300.88 s on its own (bootstrap's
|
||||
stage timeout), so one slow integration holds a start stage for about 5
|
||||
minutes. The whole start can take longer: the live one took 414 s.
|
||||
|
||||
Before this change the page said "Not ready — Battery level: no usable
|
||||
reading", which sends the reader to Developer Tools for an entity that is
|
||||
fine.
|
||||
|
||||
## Rule
|
||||
|
||||
1. No way around the Supervisor. The add-on still talks to Home Assistant
|
||||
only through the proxy.
|
||||
2. While the proxy does not answer on the API (`hass.OUTAGE.waiting()`), the
|
||||
first status row is red: "Home Assistant is not answering, perhaps it is
|
||||
still starting. Control resumes by itself when it answers." The banner
|
||||
reads "Not ready — Waiting for Home Assistant to finish starting". The Home
|
||||
pill reads "Waiting for Home Assistant", in English and Dutch.
|
||||
3. A safety stop, a stalled control loop or shadow mode keeps its own banner
|
||||
and state over the wait, because none of them clears by itself.
|
||||
4. The log has one WARNING when Home Assistant stops answering, an INFO line
|
||||
every 5 minutes while it is down, and an INFO line with the length of the
|
||||
wait when it answers again.
|
||||
5. Only the API counts. The meter websocket alone does not, because the meter
|
||||
has its own row.
|
||||
|
||||
## Why it is safe
|
||||
|
||||
The change is text only. `cycle()`, the writes, the heartbeat, the stand-down
|
||||
on shutdown and every watchdog are untouched. `test_safety112.py` part 3 shows
|
||||
the same targets and writes with the flag on and off, for N=1 and N=2.
|
||||
|
||||
## Open, for the owner
|
||||
|
||||
The add-on cannot control while Home Assistant starts. These ways around it
|
||||
were not taken:
|
||||
|
||||
- **Talk to Core directly with a long-lived token** (`http://homeassistant:8123`).
|
||||
Core's own API answers while `NOT_RUNNING`. In the repro `/api/core/state`
|
||||
answered from 12-13 s, and a direct `number.set_value` 10 s into
|
||||
`NOT_RUNNING` returned 200 and set the value. The cost is a secret stored
|
||||
at every client site, which `hass.py` exists to avoid.
|
||||
- **Talk to the control board directly** (ESPHome native API), so control
|
||||
does not need Home Assistant at all. This is a large change.
|
||||
- **Remove the slow start at the site.** On 2026-10-12 the Solis
|
||||
integration's discovery held the start. Fixing or disabling it shortens the
|
||||
wait there, but not on a client site with another slow integration.
|
||||
@@ -186,6 +186,8 @@ The label and description each setting shows on the Configuration tab, in tab or
|
||||
| Hardware | Battery modes | `battery_modes_enabled` | Give each battery an on and off switch and a mode, set on the Batteries screen. |
|
||||
| Hardware | Solar forecast, today (kWh) | `pv_forecast_entity` | Optional. A forecast sensor with today's remaining solar energy, such as Forecast.Solar or Solcast. A battery then buys only what the sun will not give. |
|
||||
| Hardware | Solar forecast, tomorrow (kWh) | `pv_forecast_tomorrow_entity` | Optional. The same forecast for tomorrow. It helps plan a cheap hour before midnight. |
|
||||
| Hardware | Several solar forecasts, today (kWh) | `pv_forecast_entities` | Optional. One row per forecast sensor, such as one per inverter, used instead of the single one above. They are added up. |
|
||||
| Hardware | Several solar forecasts, tomorrow (kWh) | `pv_forecast_tomorrow_entities` | Optional. The same list for tomorrow. If one sensor has no reading, that day's forecast is not used. |
|
||||
| Hardware | Trust in the forecast (%) | `solar_trust_pct` | Forecasts are often too sunny. At 70 % the add-on plans with 7 of every 10 kWh forecast. |
|
||||
| Hardware | Solar production entity (W) | `pv_entity` | Optional. Your solar inverter's power sensor, positive while producing. The add-on records it and does not use it for control. |
|
||||
| Hardware | Solar production entities, per inverter (W) | `pv_entities` | Optional. Use one row per solar inverter instead of “Solar production entity” when you have several. If one stops reporting, no total is recorded. |
|
||||
@@ -539,6 +541,9 @@ With battery modes on, these choices replace the *Charging and selling on price*
|
||||
- With no prices, or too small a gap, every battery follows the house.
|
||||
|
||||
**Solar forecast** (`pv_forecast_entity`, optional). A Home Assistant sensor with the solar energy still to come today, in kWh. These work: Forecast.Solar (`sensor.energy_production_today_remaining`), Solcast PV Forecast (`sensor.solcast_pv_forecast_forecast_remaining_today`) and Open-Meteo Solar Forecast (`sensor.energy_production_today_remaining`). Set `pv_forecast_tomorrow_entity` to the matching *tomorrow* sensor to plan a cheap run before midnight.
|
||||
- **Several forecasts.** If your forecast comes as several sensors (one per inverter or roof side), list them in `pv_forecast_entities` and, for tomorrow, `pv_forecast_tomorrow_entities`, instead of the single key. They are added up, each in its own unit (Wh, kWh or MWh). Set the list or the single key for a day, not both.
|
||||
- If one of them has no reading, is stale or is not in an energy unit, that day's forecast is not used at all. A part of the sun is not counted as all of it. The status page names the source by its place in the list.
|
||||
- The hourly shape is kept only if every sensor has one. Otherwise the total is spread over the day as for Forecast.Solar.
|
||||
- Before each cheap run the add-on asks: will the sun fill the batteries before the expensive hours? It counts on `solar_trust_pct` of the forecast (70 %), less what the house uses. Solar first batteries get that sun first.
|
||||
- *Leftover solar* then charges from the grid only the shortfall: what the house will draw from it in the expensive hours, less its share of the sun. Not up to the top level.
|
||||
- *Cheap hours only* ignores the forecast and fills to the top level.
|
||||
@@ -605,6 +610,10 @@ still moving towards the request, such as one turning from charging to
|
||||
giving (SAFETY-94). "Gives" is counted from what the battery's reading shows
|
||||
at rest, which the add-on learns after two quiet minutes and keeps: some
|
||||
inverters show about -100 W at rest (SAFETY-97).
|
||||
While another task sets the power, such as a maintenance charge, the peak
|
||||
guard or a trade, the refusal stays as long as the battery still refuses that
|
||||
task's request. It is logged once, and the 200 W test waits until control sets
|
||||
the power again (SAFETY-107).
|
||||
|
||||
**With two or more inverters** the same rule works per inverter. An inverter
|
||||
whose battery gives less than 100 W for 12 cycles, and at least 22 s, while
|
||||
@@ -618,7 +627,7 @@ If the battery refuses to give power while its level reads above its “Battery
|
||||
cut-out level”, the log adds one warning ending in `REFUSES_ABOVE_CUT_OUT`: check that setting.
|
||||
A battery that refuses is not reported as *not delivering*.
|
||||
|
||||
*For installers:* SAFETY-52 and SAFETY-73. The event log reads
|
||||
*For installers:* SAFETY-52, SAFETY-73 and SAFETY-107. The event log reads
|
||||
`BATTERY REFUSES …` and `BATTERY REFUSES ENDED …` (with the inverter's name at
|
||||
N>1), and the INFO line ends in `BATTERY_REFUSES`.
|
||||
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures and
|
||||
@@ -3469,6 +3478,7 @@ for a new install*.
|
||||
|
||||
| Row starts with | What it tells you |
|
||||
|---|---|
|
||||
| Home Assistant is not answering | Home Assistant is not passing readings or power requests on, usually because it is still starting. The add-on cannot control until then. It resumes by itself. Nothing to do unless it lasts. |
|
||||
| Control | When control last ran. Red when it has stopped running: the control board then sets the inverter to 0 W. |
|
||||
| Meter | The grid reading, its age, how many readings were refused, and how long its value has not changed. Just after a start it is amber and *waiting for the first reading*. Red means no reading for longer than the limit. |
|
||||
| Stuck-meter check | Whether the add-on can warn you about a stuck meter. |
|
||||
@@ -3527,6 +3537,13 @@ reason code, and its full figures are on the DEBUG line right after it and in
|
||||
(TARIFF-11), in words.
|
||||
- **Solar production** reads `pv_entity` or `pv_entities` (TEL-11/12). The
|
||||
*Reversed-sign solar entities* setting is `pv_invert_entities` (TEL-14).
|
||||
- **Home Assistant is not answering** (SAFETY-112): the Supervisor answers
|
||||
502 to every add-on read, write and websocket until Home Assistant is
|
||||
RUNNING, even when its entities are already live. A slow integration at
|
||||
start-up therefore holds control for as long as it holds Home Assistant's
|
||||
start. The log has one WARNING, a "Still waiting" INFO line every 5
|
||||
minutes and "answers again after …" at the end. See
|
||||
`DECISIONS/SAFETY-112-waiting-for-home-assistant.md`.
|
||||
- **Shadow mode** (SAFETY-10): the banner turns red when a latch is up
|
||||
(circulating power, or a site or per-inverter sign trip), and that latch keeps
|
||||
its own red row.
|
||||
|
||||
@@ -11,6 +11,8 @@ import time
|
||||
|
||||
import aiohttp
|
||||
|
||||
from . import messages
|
||||
|
||||
_LOG = logging.getLogger("goodwe.hass")
|
||||
|
||||
CORE_API = "http://supervisor/core/api"
|
||||
@@ -19,6 +21,7 @@ BAD_STATES = ("unknown", "unavailable", "none", "")
|
||||
# What the Supervisor's proxy answers while Home Assistant restarts.
|
||||
UNAVAILABLE = (502, 503, 504)
|
||||
STATES_TIMEOUT_S = 10 # UX-13's entity list, like every other read here
|
||||
STILL_WAITING_S = 300 # SAFETY-112: one reminder line per 5 minutes down
|
||||
|
||||
|
||||
class Outage:
|
||||
@@ -29,15 +32,30 @@ class Outage:
|
||||
("502, message='Bad Gateway', url=URL(...)", "Received message 8:1000 is
|
||||
not str"). Now the first channel to fail says it once at WARNING, the raw
|
||||
text goes to DEBUG, and the last channel to recover says so at INFO.
|
||||
|
||||
SAFETY-112: the Supervisor answers 502 for every read, write and
|
||||
websocket until Home Assistant has finished starting, however live its
|
||||
entities already are (DECISIONS/SAFETY-112-waiting-for-home-assistant.md).
|
||||
So an outage also says, every STILL_WAITING_S, that it is still on, and
|
||||
`waiting()` puts it on the status page.
|
||||
"""
|
||||
|
||||
def __init__(self):
|
||||
self.down_on = set()
|
||||
self.since = None # monotonic start of this outage
|
||||
self._told = None # when the last "still waiting" line went
|
||||
|
||||
def down(self, channel: str, what: str, detail) -> None:
|
||||
now = time.monotonic()
|
||||
if not self.down_on:
|
||||
_LOG.warning("Home Assistant is not answering (%s), perhaps it is "
|
||||
"restarting. The add-on keeps trying.", what)
|
||||
"still starting. Control waits and resumes by itself.",
|
||||
what)
|
||||
self.since = self._told = now
|
||||
elif now - self._told >= STILL_WAITING_S:
|
||||
self._told = now
|
||||
_LOG.info("Still waiting for Home Assistant to finish starting, "
|
||||
"%s so far.", messages.duration(now - self.since))
|
||||
self.down_on.add(channel)
|
||||
_LOG.debug("Home Assistant not answering on %s: %s", channel, detail)
|
||||
|
||||
@@ -45,7 +63,13 @@ class Outage:
|
||||
if channel in self.down_on:
|
||||
self.down_on.discard(channel)
|
||||
if not self.down_on:
|
||||
_LOG.info("Home Assistant answers again.")
|
||||
_LOG.info("Home Assistant answers again after %s.",
|
||||
messages.duration(time.monotonic() - self.since))
|
||||
|
||||
def waiting(self) -> bool:
|
||||
"""True while Home Assistant's API does not answer. The API, not the
|
||||
meter websocket: every battery reading and every write rides on it."""
|
||||
return "api" in self.down_on
|
||||
|
||||
|
||||
OUTAGE = Outage()
|
||||
|
||||
@@ -909,13 +909,14 @@ def month_peak(c, now):
|
||||
return out
|
||||
|
||||
|
||||
def state_of(c, level, shadow):
|
||||
def state_of(c, level, shadow, waiting=False):
|
||||
"""One word for the pill and the banner's colour: running, shadow,
|
||||
stopped, alarm or warning."""
|
||||
stopped, alarm, waiting or warning. `waiting`: the red headline is
|
||||
Home Assistant still starting (SAFETY-112), which needs nobody."""
|
||||
if shadow:
|
||||
return "shadow"
|
||||
if level == "bad":
|
||||
return "alarm"
|
||||
return "waiting" if waiting else "alarm"
|
||||
if not c.auto:
|
||||
return "stopped"
|
||||
if level == "warn":
|
||||
@@ -924,20 +925,22 @@ def state_of(c, level, shadow):
|
||||
|
||||
|
||||
def build(c, *, level: str, checks: list, now: datetime | None = None,
|
||||
lang: str = "en", held: bool | None = None) -> dict:
|
||||
lang: str = "en", held: bool | None = None,
|
||||
waiting: bool = False) -> dict:
|
||||
"""The structured half of `/status`, in `lang` (UX-13 P5). Pure reads of
|
||||
the controller."""
|
||||
_LANG[0] = uitext.lang_of(lang)
|
||||
try:
|
||||
return _build(c, level=level, checks=checks, now=now, held=held)
|
||||
return _build(c, level=level, checks=checks, now=now, held=held,
|
||||
waiting=waiting)
|
||||
finally:
|
||||
_LANG[0] = "en"
|
||||
|
||||
|
||||
def _build(c, *, level, checks, now, held=None):
|
||||
def _build(c, *, level, checks, now, held=None, waiting=False):
|
||||
now = now or datetime.now(timezone.utc)
|
||||
shadow = bool(c.shadow)
|
||||
kind = state_of(c, level, shadow)
|
||||
kind = state_of(c, level, shadow, waiting)
|
||||
# A red banner means every inverter is at 0 W (the status cascade), so
|
||||
# nothing is planned until it clears. Shadow mode still plans: it is
|
||||
# what the add-on would do. `held` False: an alarm while control runs
|
||||
@@ -1332,7 +1335,7 @@ def _samples() -> list:
|
||||
out += [("title", mode_word(k)) for k in words["modes"]]
|
||||
out += [("title", mode_house()), ("title", attn_shadow()),
|
||||
("line", attn_shadow_body())]
|
||||
for k in ("running", "shadow", "stopped", "alarm", "warning"):
|
||||
for k in ("running", "shadow", "stopped", "alarm", "waiting", "warning"):
|
||||
out += [("title", pill(k)), ("line", banner_sub(k))]
|
||||
for sh in (False, True):
|
||||
out += [("title", tile_solar(v, s)) for v, s in
|
||||
|
||||
@@ -69,7 +69,7 @@ from . import messages
|
||||
from .freeze import (
|
||||
FreezeWatchdog, FreezeWatchdogConfig, looks_frozen, rail_unreachable, rail_w,
|
||||
)
|
||||
from .hass import CORE_API, HomeAssistant
|
||||
from .hass import CORE_API, OUTAGE, HomeAssistant
|
||||
# ⚠️ `LINK_STALE_S` IS RE-EXPORTED DELIBERATELY. `live_units()` reasons about it
|
||||
# and two checks read `app.main.LINK_STALE_S` to build a stale link, so the
|
||||
# window an operator would look up here is the one the roster actually uses.
|
||||
@@ -992,12 +992,17 @@ class Controller:
|
||||
self._charge_blocked_q = None
|
||||
self._ref_cheap = None
|
||||
# OPT-11 P4: the solar forecast and the day plan. Only with battery
|
||||
# modes on AND `pv_forecast_entity` set; otherwise none of this runs
|
||||
# and every mode acts as in P3 option A.
|
||||
self.fc_entity = (opts.get("pv_forecast_entity") or None) \
|
||||
if self.modes_on else None
|
||||
self.fc_tomorrow_entity = opts.get("pv_forecast_tomorrow_entity") \
|
||||
or None
|
||||
# modes on AND a forecast for today set; otherwise none of this runs
|
||||
# and every mode acts as in P3 option A. OPT-17: each day may name
|
||||
# several entities, summed (`solarfc.entities()`); `fc_entity` is
|
||||
# the first, and None means no forecast.
|
||||
self.fc_entities = (solarfc.entities(opts) if self.modes_on
|
||||
else ())
|
||||
self.fc_tomorrow_entities = solarfc.entities(opts, tomorrow=True)
|
||||
self.fc_entity = self.fc_entities[0] if self.fc_entities else None
|
||||
# OPT-17: the members that are not usable, as `solarfc.read_sum()`
|
||||
# gives them, for the status page and the action log.
|
||||
self.solar_fc_gaps = ()
|
||||
self.solar_trust_pct = opts.get("solar_trust_pct",
|
||||
dayplan.DEFAULT_TRUST_PCT)
|
||||
self.solar_fc = None
|
||||
@@ -1279,9 +1284,26 @@ class Controller:
|
||||
_LOG.info("The battery refusal ends, control asks for power again: %s.",
|
||||
why)
|
||||
|
||||
def _refusal_update(self, decision, asked_w, batt_w, probe) -> None:
|
||||
"""Follow `compute()`'s carried refused direction, and say so."""
|
||||
def _refusal_update(self, decision, asked_w, batt_w, probe,
|
||||
rejudged: int = 0) -> None:
|
||||
"""Follow `compute()`'s carried refused direction, and say so.
|
||||
|
||||
`rejudged`: the refusal held while another writer had the wire, so
|
||||
`compute()` judged it afresh against that writer's ask (SAFETY-107).
|
||||
"""
|
||||
now = decision.refused or 0
|
||||
if rejudged:
|
||||
if now == rejudged:
|
||||
# Still refused against the ask on the wire: the same episode.
|
||||
# The probe clock restarts, as it did when this was an end and
|
||||
# a new start: a probe is the loop's ask, and it is not on the
|
||||
# wire while another writer is.
|
||||
self.batt_refused_at = self._now_mono
|
||||
return
|
||||
gave = (rejudged * (batt_w - self._site_idle_w())
|
||||
>= _ctl.PROBE_ANSWER_W)
|
||||
self._refusal_end("the battery gives power" if gave
|
||||
else "another writer")
|
||||
if now and not self.batt_refused:
|
||||
self._refusal_start(now, f"asked {asked_w:+.0f} W, the battery "
|
||||
f"gave {batt_w:+.0f} W for "
|
||||
@@ -3229,18 +3251,31 @@ class Controller:
|
||||
async def _read_forecast(self) -> None:
|
||||
"""OPT-11 P4: the solar forecast sensors (`solarfc.read()`). A
|
||||
failed or stale read is no forecast, never a zero."""
|
||||
today = await self.hass.state(self.fc_entity)
|
||||
tomorrow = (await self.hass.state(self.fc_tomorrow_entity)
|
||||
if self.fc_tomorrow_entity else None)
|
||||
# OPT-17: every member of both days in one gather.
|
||||
ents = self.fc_entities + self.fc_tomorrow_entities
|
||||
states = await asyncio.gather(*(self.hass.state(e) for e in ents))
|
||||
n = len(self.fc_entities)
|
||||
now = datetime.now(timezone.utc)
|
||||
fc, why = solarfc.read(today, tomorrow, now)
|
||||
if (fc is None) != (self.solar_fc is None) or why != self.solar_fc_why:
|
||||
fc, why, gaps = solarfc.read_sum(
|
||||
list(zip(self.fc_entities, states[:n])),
|
||||
list(zip(self.fc_tomorrow_entities, states[n:])), now)
|
||||
# A member is named only in a sum of several; one entity reads as
|
||||
# before. Logged once per episode: on a change, never every read.
|
||||
gaps = tuple(g for g in gaps if len(
|
||||
self.fc_entities if g[0] == "today"
|
||||
else self.fc_tomorrow_entities) > 1)
|
||||
if (fc is None) != (self.solar_fc is None) \
|
||||
or why != self.solar_fc_why or gaps != self.solar_fc_gaps:
|
||||
self.log_event(
|
||||
"solar forecast: " + ("read" if fc is not None else
|
||||
f"none ({why})"),
|
||||
hint=messages.hint("forecast_read" if fc is not None
|
||||
else "forecast_none"))
|
||||
f"none ({why})")
|
||||
+ "".join(f", {d} {e} not usable ({w})"
|
||||
for d, _i, e, w in gaps),
|
||||
hint=messages.hint(
|
||||
"forecast_none" if fc is None else
|
||||
"forecast_no_tomorrow" if gaps else "forecast_read"))
|
||||
self.solar_fc, self.solar_fc_why = fc, why
|
||||
self.solar_fc_gaps = gaps
|
||||
|
||||
async def read_inputs(self, now_mono: float | None = None) -> None:
|
||||
"""Every input this cycle needs, and SAFETY-37's freshness verdict.
|
||||
@@ -4973,11 +5008,15 @@ class Controller:
|
||||
if trade_was and not mode_trade:
|
||||
self._reseed_run_edge(claims)
|
||||
# SAFETY-52: another writer overrode the loop, so a refusal learned
|
||||
# against the loop's own ask no longer describes the wire. A gap
|
||||
# against the loop's own ask may no longer describe the wire. A gap
|
||||
# (`loop_w` None: blind or stopped) keeps it: the stale-reading stop
|
||||
# is what seeds it, and dropping it there restarts the ~70 s cycle.
|
||||
# SAFETY-107: it ends only if compute() no longer finds it against
|
||||
# that writer's ask (`_refusal_update()`). A held refusal makes the
|
||||
# loop ask 0 W, so any claim that binds differs from it every cycle.
|
||||
rejudged = 0
|
||||
if self.loop_w is not None and self.target != self.loop_w:
|
||||
self._refusal_end("another writer")
|
||||
rejudged = self.batt_refused
|
||||
# SAFETY-96: a battery that dropped out of the split leaves the
|
||||
# loop's start point (SAFETY-93's own if its charge ended too).
|
||||
self._reseed_drop(_live96)
|
||||
@@ -4986,7 +5025,8 @@ class Controller:
|
||||
# SAFETY-95: then a drain that ended, last (it reads the start
|
||||
# the others left).
|
||||
self._reseed_drain_end(maint_results, _live96)
|
||||
probe = self._refusal_probe()
|
||||
# No probe while it is judged afresh (the loop does not hold the wire).
|
||||
probe = False if rejudged else self._refusal_probe()
|
||||
if len(self.inverters) > 1:
|
||||
probe = any(_probing.values())
|
||||
# ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF.
|
||||
@@ -5029,7 +5069,8 @@ class Controller:
|
||||
# limit already closes an empty battery's discharge end.
|
||||
# SAFETY-73: at N>1 the site law holds 0 W only while every
|
||||
# unit refuses the same way. Otherwise None, the old law.
|
||||
refused=self.batt_refused if len(self.inverters) == 1
|
||||
refused=(0 if rejudged else self.batt_refused)
|
||||
if len(self.inverters) == 1
|
||||
else self._site_refused(),
|
||||
probe=probe,
|
||||
# SAFETY-94: at N=1 the engage also needs the reading to have
|
||||
@@ -5055,7 +5096,8 @@ class Controller:
|
||||
self.loop_w = decision.target_w
|
||||
self._loop_decision = decision
|
||||
if len(self.inverters) == 1:
|
||||
self._refusal_update(decision, loop_prev, site_batt, probe)
|
||||
self._refusal_update(decision, loop_prev, site_batt, probe,
|
||||
rejudged)
|
||||
# --- TEL-10 ------------------------------------------------------
|
||||
# ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT
|
||||
# THE CARD IS. `self.i_w` is carried between cycles and published
|
||||
@@ -6548,6 +6590,14 @@ class Controller:
|
||||
else:
|
||||
out.append({"ok": True, "warn": False, "id": "controller",
|
||||
"text": messages.row_controller_ran(_pass_age)})
|
||||
# SAFETY-112. The headline unless control has stalled: while the
|
||||
# Supervisor gives 502 (Home Assistant not yet RUNNING) no reading or
|
||||
# write gets through, and the rows below that need it follow from it.
|
||||
if OUTAGE.waiting():
|
||||
out.insert(1 if out[0]["ok"] is False else 0,
|
||||
{"ok": False, "warn": False, "id": "home_assistant",
|
||||
"banner": messages.banner_ha_waiting(),
|
||||
"text": messages.row_ha_waiting()})
|
||||
if self.p1_enabled:
|
||||
age = self.p1.published_age_s
|
||||
if (self.p1.stale and self.p1.age_s() is None
|
||||
@@ -6974,6 +7024,17 @@ class Controller:
|
||||
# is both is a check nobody reads.
|
||||
out.append({"ok": False, "warn": True, "id": "peak_forecast",
|
||||
"text": messages.row_no_peak_forecast()})
|
||||
# OPT-17: a forecast summed from several entities names, by position,
|
||||
# each member with no usable reading. A caution: control goes on.
|
||||
gaps = getattr(self, "solar_fc_gaps", ())
|
||||
for day, ents in (("today", getattr(self, "fc_entities", ())),
|
||||
("tomorrow",
|
||||
getattr(self, "fc_tomorrow_entities", ()))):
|
||||
gone = [i for d, i, _e, _w in gaps if d == day]
|
||||
if gone:
|
||||
out.append({"ok": False, "warn": True, "id": "solar_forecast",
|
||||
"text": messages.row_forecast_gap(
|
||||
day, gone, len(ents))})
|
||||
# --- TEL-11 ----------------------------------------------------------
|
||||
# ⚠️ NO ROW AT ALL WHEN THE ROSTER IS EMPTY, AND THAT IS A DELIBERATE
|
||||
# DIFFERENCE FROM THE PEAK-FORECAST CAUTION DIRECTLY ABOVE. That one
|
||||
@@ -7046,7 +7107,7 @@ class Controller:
|
||||
# control goes on, so it neither reads "Not ready" nor holds the page.
|
||||
runs = [c for c in bad if c.get("runs")]
|
||||
bad = [c for c in bad if not c.get("runs")]
|
||||
running_alarm = False
|
||||
running_alarm = waiting = False
|
||||
# --- SAFETY-10, AND IT IS FIRST IN THE CASCADE -----------------------
|
||||
# "The battery is NOT being controlled" is the one sentence on this
|
||||
# page that may never be displaced by another condition. A banner that
|
||||
@@ -7097,6 +7158,10 @@ class Controller:
|
||||
# headline nobody reads. UX-08: without the key, the banner takes
|
||||
# the row's first sentence, so it stays a headline.
|
||||
level, banner = "bad", messages.banner_not_ready(bad[0])
|
||||
# SAFETY-112: nothing to do but wait, so Home says that instead
|
||||
# of "Needs you now". Only when it IS the headline: a safety stop
|
||||
# above outranks it and still needs a person.
|
||||
waiting = bad[0].get("id") == "home_assistant"
|
||||
elif not self.auto:
|
||||
level, banner = "warn", messages.banner_stopped()
|
||||
elif runs:
|
||||
@@ -7243,7 +7308,7 @@ class Controller:
|
||||
# fields are served alone (the page then shows the installer details).
|
||||
try:
|
||||
out.update(homeview.build(self, level=level, checks=checks,
|
||||
lang=lang, held=held))
|
||||
lang=lang, held=held, waiting=waiting))
|
||||
except Exception: # noqa: BLE001
|
||||
# Once per process at ERROR: the page polls every 3 s.
|
||||
if not getattr(self, "_home_failed", False):
|
||||
|
||||
@@ -541,11 +541,29 @@ class Maintenance:
|
||||
events.append(msg)
|
||||
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
|
||||
|
||||
def _hold(self, now: datetime, events: list) -> MaintResult:
|
||||
"""HOLD for one tick, with or without a SoC reading (MAINT-15).
|
||||
|
||||
HOLD needs no level to end: it is reached only after the charge counted
|
||||
as done (MAINT-13/14), so its end is a time check and nothing else.
|
||||
"""
|
||||
elapsed = self._elapsed_min(now)
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
|
||||
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
|
||||
events: list) -> MaintResult:
|
||||
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
|
||||
|
||||
HOLD is unchanged (0 W). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
HOLD stays at 0 W and ends at its normal time (MAINT-15). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
|
||||
time is a failure, except when the last SoC seen was within
|
||||
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
|
||||
@@ -563,7 +581,7 @@ class Maintenance:
|
||||
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
|
||||
>= NOSOC_NOTE_MIN * 60):
|
||||
self._nosoc_said = True
|
||||
tail = ("The hold waits for the level to come back."
|
||||
tail = ("The hold still ends at its normal time."
|
||||
if phase == HOLD else
|
||||
f"The time limit of the {phase} still applies.")
|
||||
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
|
||||
@@ -571,7 +589,7 @@ class Maintenance:
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._hold(now, events)
|
||||
elapsed = self._elapsed_min(now)
|
||||
if phase == DRAIN:
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
@@ -736,16 +754,7 @@ class Maintenance:
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
if phase == HOLD:
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._hold(now, events)
|
||||
|
||||
_LOG.error("maintenance: unknown phase %r, forcing idle", phase)
|
||||
events += self.abort(now, f"unknown phase {phase!r}")
|
||||
|
||||
@@ -436,6 +436,17 @@ def banner_shadow(latched: bool) -> str:
|
||||
return "Shadow mode: the battery is not controlled. Inverters stay at 0 W."
|
||||
|
||||
|
||||
def banner_ha_waiting() -> str:
|
||||
"""SAFETY-112: the Supervisor passes nothing on until Home Assistant has
|
||||
finished starting, so the add-on can neither read nor write."""
|
||||
return "Waiting for Home Assistant to finish starting"
|
||||
|
||||
|
||||
def row_ha_waiting() -> str:
|
||||
return ("Home Assistant is not answering, perhaps it is still starting. "
|
||||
"Control resumes by itself when it answers.")
|
||||
|
||||
|
||||
# Rows: control and the meter. "Control" is what the add-on does, as in
|
||||
# "start control" (STYLE.md section 4).
|
||||
def row_controller_starting() -> str:
|
||||
@@ -754,6 +765,15 @@ def row_pv_partial(missing, count) -> str:
|
||||
f"reading")
|
||||
|
||||
|
||||
def row_forecast_gap(day, missing, count) -> str:
|
||||
"""OPT-17. `day` is "today" or "tomorrow"; `missing` are the 1-based
|
||||
positions of the forecast entities with no usable reading."""
|
||||
which = names([str(n) for n in missing])
|
||||
many = len(missing) > 1
|
||||
return (f"Solar forecast for {day}: not used, source{'s' if many else ''} "
|
||||
f"{which} of {count} {'have' if many else 'has'} no reading")
|
||||
|
||||
|
||||
def row_pv_single_ignored() -> str:
|
||||
return f"Solar production: clear {PV_ONE}, the per-inverter list replaces it"
|
||||
|
||||
@@ -953,6 +973,7 @@ HINTS = {
|
||||
"trade_off": "Trading: waiting for a better price",
|
||||
"forecast_read": "Solar forecast read, the day plan uses it",
|
||||
"forecast_none": "No solar forecast, so Leftover solar takes solar only",
|
||||
"forecast_no_tomorrow": "Tomorrow's solar forecast is not used, a source has no reading",
|
||||
"split": "The power split between inverters changed",
|
||||
"clash": "Two limits clash, inverters set to 0 W",
|
||||
"no_setpoint": "An inverter has no “Setpoint entity”, inverters stay at 0 W",
|
||||
@@ -1045,6 +1066,10 @@ def status_samples() -> list:
|
||||
("banner_setup_only", None, banner_setup_only()),
|
||||
("row_setup_only", AMBER, row_setup_only()),
|
||||
("banner_shadow", None, banner_shadow(True)),
|
||||
("banner_not_ready", None, banner_not_ready(
|
||||
{"text": row_ha_waiting(), "banner": banner_ha_waiting()})),
|
||||
("banner_ha_waiting", None, banner_ha_waiting()),
|
||||
("row_ha_waiting", RED, row_ha_waiting()),
|
||||
("row_controller_starting", GREEN, row_controller_starting()),
|
||||
("row_controller_ran", GREEN, row_controller_ran(2)),
|
||||
("row_controller_stalled", RED, row_controller_stalled(45, 30)),
|
||||
@@ -1114,6 +1139,8 @@ def status_samples() -> list:
|
||||
"entity - it cannot be read in watts")),
|
||||
("row_pv_partial", AMBER, row_pv_partial([2, 3], 3)),
|
||||
("row_pv_partial", AMBER, row_pv_partial([2], 2)),
|
||||
("row_forecast_gap", AMBER, row_forecast_gap("today", [2], 3)),
|
||||
("row_forecast_gap", AMBER, row_forecast_gap("tomorrow", [1, 2], 2)),
|
||||
("row_pv_single_ignored", AMBER, row_pv_single_ignored()),
|
||||
("row_pv_negative", AMBER, row_pv_negative(2, 3, -1500, False)),
|
||||
("row_pv_negative", AMBER, row_pv_negative(1, 1, -1500, True)),
|
||||
@@ -1232,6 +1259,8 @@ LABELS = {
|
||||
"pv_entities": "Solar production entities, per inverter",
|
||||
"pv_forecast_entity": "Solar forecast, today",
|
||||
"pv_forecast_tomorrow_entity": "Solar forecast, tomorrow",
|
||||
"pv_forecast_entities": "Several solar forecasts, today",
|
||||
"pv_forecast_tomorrow_entities": "Several solar forecasts, tomorrow",
|
||||
"solar_trust_pct": "Trust in the forecast",
|
||||
"p1_phase_import_entities": "Import entities per phase",
|
||||
"p1_phase_export_entities": "Export entities per phase",
|
||||
|
||||
@@ -27,6 +27,11 @@ Without an hourly split, the day's energy is spread over a fixed bell from
|
||||
A reading older than `FRESH_S`, or from before local midnight, is stale,
|
||||
and a stale or missing forecast is no forecast: the day plan is off and
|
||||
every mode acts as in P3 option A.
|
||||
|
||||
OPT-17: each day may instead name a list (`pv_forecast_entities`,
|
||||
`pv_forecast_tomorrow_entities`), summed by `read_sum()`. One member that is
|
||||
not usable makes that day's sum unusable, never a partial sum.
|
||||
DECISIONS/OPT-17-several-forecast-entities.md.
|
||||
"""
|
||||
|
||||
import math
|
||||
@@ -49,6 +54,12 @@ BELL_FROM_H, BELL_TO_H = 6.0, 20.0
|
||||
NOT_SET, MISSING, UNIT, STALE, BAD = (
|
||||
"not_set", "missing", "unit", "stale", "bad")
|
||||
|
||||
# OPT-17: (single key, list key) per day. A set list replaces the single key;
|
||||
# the validator refuses both set for the same day.
|
||||
TODAY_KEYS = ("pv_forecast_entity", "pv_forecast_entities")
|
||||
TOMORROW_KEYS = ("pv_forecast_tomorrow_entity",
|
||||
"pv_forecast_tomorrow_entities")
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class Day:
|
||||
@@ -223,6 +234,52 @@ def _reported(state):
|
||||
return max(ts) if ts else None
|
||||
|
||||
|
||||
def entities(opts: dict, *, tomorrow=False) -> tuple:
|
||||
"""The forecast entities one day names, in configured order: the list
|
||||
if it has any entry, else the single key, else (). A repeated id is
|
||||
dropped, as `pv.entities()` does: it would count one forecast twice."""
|
||||
one, many = TOMORROW_KEYS if tomorrow else TODAY_KEYS
|
||||
listed = [e for e in (str(x or "").strip()
|
||||
for x in (opts.get(many) or [])) if e]
|
||||
if listed:
|
||||
return tuple(dict.fromkeys(listed))
|
||||
e = str(opts.get(one) or "").strip()
|
||||
return (e,) if e else ()
|
||||
|
||||
|
||||
def _bounds(now):
|
||||
here = now.astimezone(BILLING_TZ)
|
||||
d0 = datetime(here.year, here.month, here.day, tzinfo=BILLING_TZ)
|
||||
nd = d0.date() + timedelta(days=1)
|
||||
d1 = datetime(nd.year, nd.month, nd.day, tzinfo=BILLING_TZ)
|
||||
return d0.astimezone(timezone.utc), d1.astimezone(timezone.utc)
|
||||
|
||||
|
||||
def _today(state, day0, now):
|
||||
"""`(Day, at, None)` or `(None, None, why)` for one today sensor."""
|
||||
today, why = _day(state, day0, now, today=True)
|
||||
if today is None:
|
||||
return None, None, why
|
||||
at = _reported(state)
|
||||
# A reading from before local midnight is yesterday's "left today" (0
|
||||
# after sunset) until the integration refreshes: stale, not a dark day.
|
||||
if at is None or at < day0 or (now - at).total_seconds() > FRESH_S \
|
||||
or (at - now).total_seconds() > 300:
|
||||
return None, None, STALE
|
||||
return today, at, None
|
||||
|
||||
|
||||
def _tomorrow(state, day0, day1, now):
|
||||
"""`(Day, None)` or `(None, why)` for one tomorrow sensor."""
|
||||
t, why = _day(state, day1, now, today=False)
|
||||
if t is None:
|
||||
return None, why
|
||||
t_at = _reported(state)
|
||||
if t_at is None or t_at < day0 or (now - t_at).total_seconds() > FRESH_S:
|
||||
return None, STALE
|
||||
return t, None
|
||||
|
||||
|
||||
def read(today_state, tomorrow_state, now: datetime, *,
|
||||
configured=True):
|
||||
"""`(Forecast, None)` or `(None, why)`. `tomorrow_state` may be None
|
||||
@@ -230,25 +287,64 @@ def read(today_state, tomorrow_state, now: datetime, *,
|
||||
covers today only."""
|
||||
if not configured:
|
||||
return None, NOT_SET
|
||||
here = now.astimezone(BILLING_TZ)
|
||||
d0 = datetime(here.year, here.month, here.day, tzinfo=BILLING_TZ)
|
||||
nd = d0.date() + timedelta(days=1)
|
||||
d1 = datetime(nd.year, nd.month, nd.day, tzinfo=BILLING_TZ)
|
||||
day0, day1 = d0.astimezone(timezone.utc), d1.astimezone(timezone.utc)
|
||||
today, why = _day(today_state, day0, now, today=True)
|
||||
day0, day1 = _bounds(now)
|
||||
today, at, why = _today(today_state, day0, now)
|
||||
if today is None:
|
||||
return None, why
|
||||
at = _reported(today_state)
|
||||
# A reading from before local midnight is yesterday's "left today" (0
|
||||
# after sunset) until the integration refreshes: stale, not a dark day.
|
||||
if at is None or at < day0 or (now - at).total_seconds() > FRESH_S \
|
||||
or (at - now).total_seconds() > 300:
|
||||
return None, STALE
|
||||
tomorrow = None
|
||||
if tomorrow_state is not None:
|
||||
t, _w = _day(tomorrow_state, day1, now, today=False)
|
||||
t_at = _reported(tomorrow_state)
|
||||
if t is not None and t_at is not None and t_at >= day0 \
|
||||
and (now - t_at).total_seconds() <= FRESH_S:
|
||||
tomorrow = t
|
||||
tomorrow, _w = _tomorrow(tomorrow_state, day0, day1, now)
|
||||
return Forecast(today, tomorrow, at), None
|
||||
|
||||
|
||||
def _sum(days):
|
||||
"""One Day from several members' Days. The hourly split is kept only if
|
||||
every member has one: the splits are then joined (`_day_between()`
|
||||
adds overlapping periods). Else the total goes on the bell."""
|
||||
if len(days) == 1:
|
||||
return days[0]
|
||||
periods = ()
|
||||
if all(d.periods for d in days):
|
||||
periods = tuple(sorted(p for d in days for p in d.periods))
|
||||
return Day(days[0].day0, sum(d.kwh for d in days), periods)
|
||||
|
||||
|
||||
def read_sum(today, tomorrow, now: datetime):
|
||||
"""OPT-17: `(Forecast or None, why, gaps)` over lists of
|
||||
`(entity, state)`, one per configured member, in configured order.
|
||||
|
||||
Each member is read exactly as `read()` reads one sensor, in its own
|
||||
unit. A member that is missing, unavailable, stale, not in an energy
|
||||
unit or bad makes that DAY unusable, as one such sensor does today: no
|
||||
today means no forecast, no tomorrow means today only. A partial sum
|
||||
would under-count the sun and mislead the day plan.
|
||||
|
||||
`gaps` is `((day, position, entity, why), ...)` for every unusable
|
||||
member (`day` "today" or "tomorrow", `position` 1-based), so the page
|
||||
and the log can name it. With one member per day the forecast is what
|
||||
`read()` gives (test_opt17.py proves it)."""
|
||||
if not today:
|
||||
return None, NOT_SET, ()
|
||||
day0, day1 = _bounds(now)
|
||||
gaps, days, ats, why0 = [], [], [], None
|
||||
for i, (ent, st) in enumerate(today, 1):
|
||||
d, at, why = _today(st, day0, now)
|
||||
if d is None:
|
||||
gaps.append(("today", i, ent, why))
|
||||
why0 = why0 or why
|
||||
else:
|
||||
days.append(d)
|
||||
ats.append(at)
|
||||
tdays = []
|
||||
for i, (ent, st) in enumerate(tomorrow, 1):
|
||||
t, why = _tomorrow(st, day0, day1, now)
|
||||
if t is None:
|
||||
gaps.append(("tomorrow", i, ent, why))
|
||||
else:
|
||||
tdays.append(t)
|
||||
gaps = tuple(gaps)
|
||||
if why0 is not None:
|
||||
return None, why0, gaps
|
||||
tday = _sum(tdays) if tomorrow and len(tdays) == len(tomorrow) else None
|
||||
# The oldest member's report is when the sum was last fully known.
|
||||
return Forecast(_sum(days), tday, min(ats)), None, gaps
|
||||
|
||||
@@ -100,7 +100,7 @@
|
||||
}
|
||||
function renderPill() {
|
||||
const st = S.state || null;
|
||||
const dot = st ? ({ running: "", shadow: " warn", stopped: " warn", warning: " warn", alarm: " bad" }[st.kind] ?? " warn")
|
||||
const dot = st ? ({ running: "", shadow: " warn", stopped: " warn", warning: " warn", alarm: " bad", waiting: " warn" }[st.kind] ?? " warn")
|
||||
: (S.level === "ok" ? "" : S.level === "bad" ? " bad" : " warn");
|
||||
const words = st ? [st.pill, st.ran].filter(Boolean).join(". ") : S.setup_only === true ? t("setup_only.name") : S.banner;
|
||||
$("#pill").replaceChildren(h("span", { class: "dot" + dot, "aria-hidden": "true" }), h("span", {}, words));
|
||||
@@ -399,7 +399,7 @@
|
||||
$("#batt-how").hidden = !modes;
|
||||
const docs = $("#batt-docs");
|
||||
if (S.control && S.control.docs_url) { docs.href = S.control.docs_url; docs.hidden = false; } else docs.hidden = true;
|
||||
if (S.state && ["shadow", "stopped", "alarm"].includes(S.state.kind)) banner($("#batt-banner"), S.level, S.state.pill, S.state.sub, S.level === "bad" ? "alert" : null);
|
||||
if (S.state && ["shadow", "stopped", "alarm", "waiting"].includes(S.state.kind)) banner($("#batt-banner"), S.level, S.state.pill, S.state.sub, S.level === "bad" ? "alert" : null);
|
||||
else $("#batt-banner").replaceChildren();
|
||||
keepFocus(() => {
|
||||
$("#bcards").replaceChildren(...S.batteries.map(batteryCard));
|
||||
|
||||
@@ -267,6 +267,7 @@
|
||||
"shadow": "Shadow mode",
|
||||
"stopped": "Stopped",
|
||||
"alarm": "Needs you now",
|
||||
"waiting": "Waiting for Home Assistant",
|
||||
"warning": "Running, with a warning"
|
||||
},
|
||||
"banner_sub": {
|
||||
@@ -274,6 +275,7 @@
|
||||
"shadow": "The plans below say what the add-on would do.",
|
||||
"stopped": "Start control below when you are ready.",
|
||||
"alarm": "See Needs attention below for what to do.",
|
||||
"waiting": "Control resumes by itself when Home Assistant answers.",
|
||||
"warning": "See Needs attention below."
|
||||
},
|
||||
"tile": {
|
||||
@@ -431,6 +433,7 @@
|
||||
"stopped": "Control is stopped. Every inverter is at 0 W."
|
||||
},
|
||||
"attn": {
|
||||
"home_assistant": "Home Assistant is not answering",
|
||||
"controller": "Control is not running",
|
||||
"meter": "Meter reading",
|
||||
"meter_frozen": "Meter reading may be stuck",
|
||||
@@ -449,6 +452,7 @@
|
||||
"delivery": "An inverter is not delivering",
|
||||
"estop": "Emergency stop",
|
||||
"pv": "Solar reading",
|
||||
"solar_forecast": "Solar forecast",
|
||||
"none": "Inverter connection"
|
||||
},
|
||||
"months": ["January", "February", "March", "April", "May", "June", "July", "August", "September", "October", "November", "December"]
|
||||
|
||||
@@ -230,8 +230,8 @@
|
||||
"zero_held": "Op 0 W gehouden",
|
||||
"zero_going": "Gaat naar 0 W",
|
||||
"verdict": {"held": "Op 0 W gehouden", "stopped": "Gestopt", "cycle": "Vandaag maandelijkse cyclus", "trade": "Handelt op prijs", "house": "Volgt het huis"},
|
||||
"pill": {"running": "Actief", "shadow": "Schaduwmodus", "stopped": "Gestopt", "alarm": "Heeft u nu nodig", "warning": "Actief, met een waarschuwing"},
|
||||
"banner_sub": {"running": "De batterijen volgen het plan hieronder.", "shadow": "De plannen hieronder tonen wat de add-on zou doen.", "stopped": "Start de regeling hieronder als u klaar bent.", "alarm": "Zie Vraagt aandacht hieronder voor wat u moet doen.", "warning": "Zie Vraagt aandacht hieronder."},
|
||||
"pill": {"running": "Actief", "shadow": "Schaduwmodus", "stopped": "Gestopt", "alarm": "Heeft u nu nodig", "waiting": "Wacht op Home Assistant", "warning": "Actief, met een waarschuwing"},
|
||||
"banner_sub": {"running": "De batterijen volgen het plan hieronder.", "shadow": "De plannen hieronder tonen wat de add-on zou doen.", "stopped": "Start de regeling hieronder als u klaar bent.", "alarm": "Zie Vraagt aandacht hieronder voor wat u moet doen.", "waiting": "De regeling gaat vanzelf verder zodra Home Assistant antwoordt.", "warning": "Zie Vraagt aandacht hieronder."},
|
||||
"tile": {"not_set_up": "Niet ingesteld", "no_reading": "Geen meting", "producing": "Produceert", "not_producing": "Produceert niet", "needs_solar": "Zonnemeting nodig", "not_adding_up": "Metingen kloppen niet", "using": "Verbruikt", "taking": "Neemt af van het net", "feeding": "Injecteert", "balanced": "In evenwicht", "giving": "Levert stroom", "charging": "Laadt", "resting": "Rust"},
|
||||
"now": {
|
||||
"no_reading": "Geen meting van deze batterij.",
|
||||
@@ -354,6 +354,7 @@
|
||||
"peak_not_covered": "Geen piekgrens: deze meter meet geen kwartieren.",
|
||||
"control": {"shadow": "Schaduwmodus: elke omvormer blijft op 0 W.", "running": "De regeling is actief.", "stopped": "De regeling is gestopt. Elke omvormer staat op 0 W."},
|
||||
"attn": {
|
||||
"home_assistant": "Home Assistant antwoordt niet",
|
||||
"controller": "Regeling is niet actief",
|
||||
"meter": "Meting van de meter",
|
||||
"meter_frozen": "Meter staat mogelijk vast",
|
||||
@@ -372,6 +373,7 @@
|
||||
"delivery": "Een omvormer levert niet",
|
||||
"estop": "Noodstop",
|
||||
"pv": "Meting van de zonnepanelen",
|
||||
"solar_forecast": "Zonneprognose",
|
||||
"none": "Verbinding met de omvormer"
|
||||
},
|
||||
"months": ["januari", "februari", "maart", "april", "mei", "juni", "juli", "augustus", "september", "oktober", "november", "december"]
|
||||
|
||||
@@ -135,6 +135,10 @@ GROUPS = (
|
||||
Field("pv_forecast_entity", ENTITY, kind="energy", simple=True,
|
||||
note="forecast"),
|
||||
Field("pv_forecast_tomorrow_entity", ENTITY, kind="energy"),
|
||||
# OPT-17: several forecast sensors per day, summed.
|
||||
Field("pv_forecast_entities", ENTITY_LIST, kind="energy"),
|
||||
Field("pv_forecast_tomorrow_entities", ENTITY_LIST,
|
||||
kind="energy"),
|
||||
Field("solar_trust_pct", SLIDER, "%", step=5),
|
||||
)),
|
||||
)),
|
||||
|
||||
@@ -1802,12 +1802,13 @@ def _entity_notes(notes, opts: dict, entities: dict, bad=()) -> None:
|
||||
_advise(notes, "warn", (key,),
|
||||
f"{entity} does not read in kWh, so pick a solar "
|
||||
"forecast sensor in kWh.")
|
||||
if any(opts.get(k) for k in FORECAST_KEYS) and \
|
||||
today = solarfc.entities(opts)
|
||||
tomorrow = solarfc.entities(opts, tomorrow=True)
|
||||
if (today or tomorrow) and \
|
||||
opts.get("battery_modes_enabled") is not True:
|
||||
_advise(notes, "info", ("pv_forecast_entity",),
|
||||
"The solar forecast is used only with battery modes on.")
|
||||
if opts.get("pv_forecast_tomorrow_entity") and \
|
||||
not opts.get("pv_forecast_entity"):
|
||||
if tomorrow and not today:
|
||||
_advise(notes, "warn", ("pv_forecast_tomorrow_entity",),
|
||||
"Tomorrow's forecast is used only with today's, so set "
|
||||
f"{S('pv_forecast_entity')} too.")
|
||||
@@ -2069,12 +2070,13 @@ def _margin_problems(opts: dict) -> list[str]:
|
||||
TRUST_RANGE_PCT = (30, 100)
|
||||
# A Home Assistant sensor id; it goes into the /api/states/<id> path.
|
||||
_SENSOR_ID = re.compile(r"sensor\.[a-z0-9_]+")
|
||||
FORECAST_KEYS = ("pv_forecast_entity", "pv_forecast_tomorrow_entity")
|
||||
FORECAST_KEYS = solarfc.TODAY_KEYS + solarfc.TOMORROW_KEYS
|
||||
|
||||
|
||||
def _forecast_problems(opts: dict) -> list[str]:
|
||||
"""Rule 13 (OPT-11 P4): the trust is a whole percentage in range, and
|
||||
each forecast entity set is a sensor."""
|
||||
each forecast entity set is a sensor. OPT-17: a day names its forecast
|
||||
in the single key or in the list, not both."""
|
||||
out = []
|
||||
raw = opts.get("solar_trust_pct")
|
||||
trust = _number(opts, "solar_trust_pct", dayplan.DEFAULT_TRUST_PCT)
|
||||
@@ -2082,14 +2084,30 @@ def _forecast_problems(opts: dict) -> list[str]:
|
||||
if trust is None or trust != int(trust) or not lo <= trust <= hi:
|
||||
out.append(f"{S('solar_trust_pct')} must be a whole number from {lo} "
|
||||
f"to {hi} %. It is {messages.shown(raw)}.")
|
||||
for key in FORECAST_KEYS:
|
||||
e = opts.get(key)
|
||||
if e is None or e == "":
|
||||
continue
|
||||
if not isinstance(e, str) or not _SENSOR_ID.fullmatch(e):
|
||||
out.append(f"{S(key)} must be a sensor, like "
|
||||
for one, many in (solarfc.TODAY_KEYS, solarfc.TOMORROW_KEYS):
|
||||
e = opts.get(one)
|
||||
if e is not None and e != "" and (
|
||||
not isinstance(e, str) or not _SENSOR_ID.fullmatch(e)):
|
||||
out.append(f"{S(one)} must be a sensor, like "
|
||||
f"sensor.energy_production_today_remaining. It is "
|
||||
f"{messages.shown(e)}.")
|
||||
raw = opts.get(many)
|
||||
if raw is None:
|
||||
raw = []
|
||||
if not isinstance(raw, list):
|
||||
out.append(f"{S(many)} must be a list of sensors. It is "
|
||||
f"{messages.shown(raw)}.")
|
||||
continue
|
||||
listed = [x for x in raw if x is not None
|
||||
and not (isinstance(x, str) and not x.strip())]
|
||||
for x in listed:
|
||||
if not isinstance(x, str) or not _SENSOR_ID.fullmatch(x):
|
||||
out.append(f"{S(many)} must list only sensors, like "
|
||||
f"sensor.energy_production_today_remaining. "
|
||||
f"It has {messages.shown(x)}.")
|
||||
if e and listed:
|
||||
out.append(f"Set {S(one)} or {S(many)}, not both. Keep the "
|
||||
f"list and clear the single one.")
|
||||
return out
|
||||
|
||||
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.16.0"
|
||||
version: "0.17.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
@@ -157,6 +157,11 @@ options:
|
||||
# integrations whose sensors fit.
|
||||
pv_forecast_entity: ""
|
||||
pv_forecast_tomorrow_entity: ""
|
||||
# OPT-17: several forecast sensors per day (one per inverter or string),
|
||||
# summed. Use the list OR the single key above, not both. `[]` is
|
||||
# load-bearing, as for `pv_entities`.
|
||||
pv_forecast_entities: []
|
||||
pv_forecast_tomorrow_entities: []
|
||||
solar_trust_pct: 70
|
||||
|
||||
# TEL-11 - THE SITE'S PV PRODUCTION, IN WATTS, AND IT IS READ BY NOTHING THAT
|
||||
@@ -961,6 +966,13 @@ schema:
|
||||
battery_modes_enabled: bool
|
||||
pv_forecast_entity: str?
|
||||
pv_forecast_tomorrow_entity: str?
|
||||
# OPT-17: new list keys beside the single ones. A list schema on the old
|
||||
# keys refuses the string an install stores (tools/supervisor_shape_probe.py
|
||||
# section J); DECISIONS/OPT-17-several-forecast-entities.md.
|
||||
pv_forecast_entities:
|
||||
- str
|
||||
pv_forecast_tomorrow_entities:
|
||||
- str
|
||||
solar_trust_pct: int(30,100)
|
||||
# TEL-11. Optional, and OPTIONAL WITHOUT A COMPANION RULE - unlike
|
||||
# `price_now_entity`/`price_avg_entity`, which are legal only while
|
||||
|
||||
@@ -245,8 +245,8 @@ m = in_charge()
|
||||
m.tick(T0 + MIN, 100.0)
|
||||
_, _, _, ev = run(m, T0 + 2 * MIN, 30, None)
|
||||
note = [e for e in ev if "no battery level for" in e]
|
||||
check("HOLD: the line exists and claims no time limit",
|
||||
len(note) == 1 and "time limit" not in note[0] and "waits" in note[0])
|
||||
check("HOLD: the line exists and says the hold ends at its normal time (MAINT-15)",
|
||||
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0])
|
||||
m = in_charge()
|
||||
_, _, _, ev = run(m, T0, 30, None)
|
||||
check("charge keeps its wording", any("time limit of the charge" in e for e in ev))
|
||||
@@ -268,7 +268,7 @@ _, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
_, _, _, ev = run(m, out[1] + MIN, 30, None)
|
||||
check("charge done with no SoC, then HOLD with no SoC: a new episode, so the "
|
||||
"HOLD line is said", out[0].phase == HOLD
|
||||
and sum("hold waits" in e for e in ev) == 1)
|
||||
and sum("normal time" in e for e in ev) == 1)
|
||||
|
||||
print("6. restart while the SoC is missing")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
|
||||
@@ -0,0 +1,299 @@
|
||||
"""MAINT-15: the HOLD ends on time with no SoC reading.
|
||||
`python3 test_maint15.py`
|
||||
|
||||
Graded here: a HOLD that loses its SoC (at the start, mid-hold, just before
|
||||
hold_min) ends on time, writes last_completed and says the COMPLETE line; SoC
|
||||
back mid-hold changes nothing; HOLD stays 0 W; one pack's loss leaves the other
|
||||
pack alone; a restart in HOLD with no SoC and an old state file.
|
||||
See DECISIONS/MAINT-15-hold-ends-without-soc.md.
|
||||
|
||||
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
|
||||
"""
|
||||
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.maintenance import (
|
||||
CHARGE, DRAIN, HOLD, IDLE, NOSOC_NOTE_MIN, MaintConfig, Maintenance,
|
||||
)
|
||||
from app.store import DEFAULTS, Store
|
||||
|
||||
UTC = timezone.utc
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=120)
|
||||
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC)
|
||||
MIN = timedelta(minutes=1)
|
||||
|
||||
|
||||
class Mem:
|
||||
def __init__(self, data=None):
|
||||
self.data = dict(DEFAULTS, **(data or {}))
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def set_time(self, k, when):
|
||||
self.data[k] = when.astimezone(UTC).isoformat() if when else None
|
||||
|
||||
def get_time(self, k):
|
||||
raw = self.data.get(k)
|
||||
return datetime.fromisoformat(raw) if raw else None
|
||||
|
||||
def save(self):
|
||||
pass
|
||||
|
||||
|
||||
def in_drain(store=None, unit=None, at=T0):
|
||||
m = Maintenance(CFG, store or Mem(), unit=unit, name=unit or "")
|
||||
m.force_start(at)
|
||||
assert m.phase == DRAIN
|
||||
return m
|
||||
|
||||
|
||||
def in_charge(store=None, unit=None, at=T0):
|
||||
m = in_drain(store, unit, at)
|
||||
m.tick(at, 11.0)
|
||||
assert m.phase == CHARGE
|
||||
return m
|
||||
|
||||
|
||||
def run(m, start, minutes, soc, gate=True, step=1):
|
||||
"""Tick every `step` min; returns (last result, end time, first result that
|
||||
is not the starting phase with its time, all events)."""
|
||||
ph, t, res, out, ev = m.phase, start, None, None, []
|
||||
for i in range(0, minutes, step):
|
||||
t = start + i * MIN
|
||||
s = soc(i) if callable(soc) else soc
|
||||
res = m.tick(t, s, gate_open=gate)
|
||||
ev += res.events
|
||||
if out is None and res.phase != ph:
|
||||
out = (res, t)
|
||||
break
|
||||
return res, start + minutes * MIN, out, ev
|
||||
|
||||
|
||||
|
||||
HOLD_MIN = CFG.hold_min
|
||||
|
||||
|
||||
def in_hold(store=None, unit=None, at=T0):
|
||||
"""A pack in HOLD that started at `at` + 1 min (charge counted as done)."""
|
||||
m = in_charge(store, unit, at)
|
||||
m.tick(at + MIN, 100.0)
|
||||
assert m.phase == HOLD
|
||||
return m
|
||||
|
||||
|
||||
H0 = T0 + MIN # the hold's start
|
||||
print("1. SoC lost in HOLD: the hold ends on time")
|
||||
for label, lost_at in (("at the start", 0), ("mid-hold", 60),
|
||||
("just before hold_min", HOLD_MIN - 1)):
|
||||
m = in_hold()
|
||||
run(m, H0, lost_at, 100.0) if lost_at else None
|
||||
res, _, out, ev = run(m, H0 + lost_at * MIN, HOLD_MIN + 5 - lost_at, None)
|
||||
check(f"lost {label}: ends at hold_min, to IDLE, not failed",
|
||||
out is not None and out[0].phase == IDLE and out[0].failed == ""
|
||||
and out[1] == H0 + HOLD_MIN * MIN)
|
||||
check("...last_completed is written at that time",
|
||||
m.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
check("...the same COMPLETE line, once, and no last_failed",
|
||||
sum("cycle COMPLETE (120 min hold)" in e for e in ev) == 1
|
||||
and m.store.get_time("last_failed") is None)
|
||||
check("...the pack is idle and hands the setpoint back",
|
||||
m.phase == IDLE and not out[0].owns_setpoint)
|
||||
|
||||
m = in_hold()
|
||||
res, _, out, _ = run(m, H0, HOLD_MIN - 1, None)
|
||||
check("before hold_min: still HOLD at 0 W, owned, nothing written",
|
||||
out is None and res.phase == HOLD and res.owns_setpoint
|
||||
and res.setpoint_w == 0.0 and m.store.get_time("last_completed") is None)
|
||||
check("...the pack is not due again (next due date moved after the end)",
|
||||
(run(m, H0 + (HOLD_MIN - 1) * MIN, 3, None), m.due(H0 + 130 * MIN))[1] is False)
|
||||
|
||||
print("2. the text")
|
||||
m = in_hold()
|
||||
_, _, out, ev = run(m, H0, HOLD_MIN + 5, None)
|
||||
note = [e for e in ev if "no battery level for" in e]
|
||||
check("one 15 min line, saying the hold ends at its normal time",
|
||||
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0]
|
||||
and f"{NOSOC_NOTE_MIN} min" in note[0])
|
||||
check("...and the other events are the one COMPLETE line only", len(ev) == 2)
|
||||
m = in_hold()
|
||||
_, _, _, ev = run(m, H0, NOSOC_NOTE_MIN - 2, None)
|
||||
check("under the threshold the line is not said", ev == [])
|
||||
|
||||
print("3. SoC comes back mid-hold")
|
||||
ends = {}
|
||||
for label, soc in (("no SoC", lambda i: None if i < 40 else 100.0),
|
||||
("SoC the whole time", 100.0),
|
||||
("a low SoC after the gap", lambda i: None if i < 40 else 55.0)):
|
||||
m = in_hold()
|
||||
res, _, out, ev = run(m, H0, HOLD_MIN + 5, soc)
|
||||
ends[label] = (out[1], m.store.get_time("last_completed")) if out else None
|
||||
check(f"{label}: ends at hold_min", out is not None
|
||||
and out[1] == H0 + HOLD_MIN * MIN)
|
||||
check("...the end time is the same with or without the gap",
|
||||
len(set(ends.values())) == 1)
|
||||
m = in_hold()
|
||||
run(m, H0, 40, None)
|
||||
res, _, out, _ = run(m, H0 + 40 * MIN, 30, 100.0)
|
||||
check("back mid-hold: still HOLD at 0 W until the time is up",
|
||||
out is None and res.phase == HOLD and res.setpoint_w == 0.0)
|
||||
|
||||
print("4. restart in HOLD with no SoC")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
path = os.path.join(d, "state.json")
|
||||
m = Maintenance(CFG, Store(path))
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
m.tick(H0, 100.0)
|
||||
run(m, H0, 50, None)
|
||||
m2 = Maintenance(CFG, Store(path))
|
||||
r = m2.tick(H0 + 51 * MIN, None)
|
||||
check("a fresh process reads HOLD and holds 0 W", m2.phase == HOLD
|
||||
and r.phase == HOLD and r.owns_setpoint and r.setpoint_w == 0.0)
|
||||
res, _, out, _ = run(m2, H0 + 52 * MIN, HOLD_MIN, None)
|
||||
check("...and the hold ends at hold_min from the hold start, not the restart",
|
||||
out and out[0].phase == IDLE and out[1] == H0 + HOLD_MIN * MIN
|
||||
and m2.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
import json
|
||||
old = {"phase": "hold", "phase_started": H0.isoformat(),
|
||||
"last_completed": None, "last_start_attempt": None, "auto": True}
|
||||
p2 = os.path.join(d, "old.json")
|
||||
json.dump(old, open(p2, "w"))
|
||||
mo = Maintenance(CFG, Store(p2))
|
||||
r = mo.tick(H0 + 10 * MIN, None)
|
||||
check("an old state file in HOLD loads and holds 0 W", mo.phase == HOLD
|
||||
and r.setpoint_w == 0.0)
|
||||
res, _, out, _ = run(mo, H0 + 11 * MIN, HOLD_MIN, None)
|
||||
check("...and ends on time, writing last_completed",
|
||||
out and out[1] == H0 + HOLD_MIN * MIN
|
||||
and mo.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
mr = Maintenance(CFG, Store(p2))
|
||||
check("...the written file reloads as a finished cycle",
|
||||
mr.phase == IDLE and mr.store.get_time("last_completed") is not None)
|
||||
|
||||
print("5. two packs")
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a_ok, b_ok = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
for x in (a, a_ok):
|
||||
x.force_start(T0)
|
||||
x.tick(T0, 11.0)
|
||||
x.tick(H0, 100.0)
|
||||
# B is idle; A's hold loses its SoC (twin site: A keeps it)
|
||||
same, a_end = True, None
|
||||
for i in range(0, HOLD_MIN + 10):
|
||||
t = H0 + i * MIN
|
||||
ra = a.tick(t, None)
|
||||
rb = b.tick(t, 60.0)
|
||||
ra2 = a_ok.tick(t, 100.0)
|
||||
rb2 = b_ok.tick(t, 60.0)
|
||||
same = same and (rb.phase, rb.owns_setpoint, rb.setpoint_w) == \
|
||||
(rb2.phase, rb2.owns_setpoint, rb2.setpoint_w) and b.phase == b_ok.phase
|
||||
if a_end is None and a.phase == IDLE:
|
||||
a_end = t
|
||||
check("A loses SoC in HOLD: A ends on time (as the twin with a reading)",
|
||||
a_end == H0 + HOLD_MIN * MIN and a_ok.phase == IDLE
|
||||
and a.store.get_time("last_completed") == a_ok.store.get_time("last_completed"))
|
||||
check("...B is the same as in the twin site where A kept its SoC", same)
|
||||
# B in its own HOLD with SoC, A in HOLD without
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a.force_start(T0); a.tick(T0, 11.0); a.tick(H0, 100.0)
|
||||
b_start = H0 + 30 * MIN
|
||||
b.force_start(b_start - MIN); b.tick(b_start - MIN, 11.0); b.tick(b_start, 100.0)
|
||||
b_end = None
|
||||
for i in range(0, HOLD_MIN + 40):
|
||||
t = H0 + i * MIN
|
||||
a.tick(t, None)
|
||||
if t >= b_start:
|
||||
b.tick(t, 100.0)
|
||||
if b_end is None and b.phase == IDLE:
|
||||
b_end = t
|
||||
check("B (SoC present) ends at its own hold_min, A's loss changes nothing",
|
||||
b_end == b_start + HOLD_MIN * MIN and a.phase == IDLE
|
||||
and b.store.get_time("last_completed") == b_start + HOLD_MIN * MIN)
|
||||
check("...A's end is not delayed by B", a.store.get_time("last_completed")
|
||||
== H0 + HOLD_MIN * MIN)
|
||||
|
||||
print("6. other phases unchanged")
|
||||
m = in_drain()
|
||||
res, _, out, _ = run(m, T0, 60, None)
|
||||
check("DRAIN with no SoC still holds 0 W and does not end", out is None
|
||||
and res.phase == DRAIN and res.setpoint_w == 0.0)
|
||||
m = in_charge()
|
||||
res, _, out, _ = run(m, T0, 600, None)
|
||||
check("CHARGE with no SoC still keeps charging", out is None
|
||||
and res.phase == CHARGE and res.charge_only)
|
||||
|
||||
|
||||
def old_hold_branch(phase_started, last_completed, now, hold_min):
|
||||
"""FROZEN copy of release/1.0 (db9e231) HOLD branch of step(), with a
|
||||
reading: returns (phase, owns_setpoint, setpoint_w, events,
|
||||
last_completed). Kept as a reference for the differential check below."""
|
||||
elapsed = (now - phase_started).total_seconds() / 60.0
|
||||
if elapsed >= hold_min:
|
||||
return (IDLE, False, None,
|
||||
[f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop"], now)
|
||||
return (HOLD, True, 0.0, [], last_completed)
|
||||
|
||||
|
||||
print("7. with a reading: the new HOLD against the frozen release/1.0 branch")
|
||||
for hm in (0, 5, 60, 120):
|
||||
cfg = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=hm)
|
||||
m = Maintenance(cfg, Mem())
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
m.tick(H0, 100.0)
|
||||
started, last, same, end = H0, None, True, None
|
||||
for i in range(0, hm + 15):
|
||||
t = H0 + i * MIN
|
||||
if m.phase != HOLD:
|
||||
break
|
||||
want = old_hold_branch(started, last, t, hm)
|
||||
r = m.tick(t, 100.0 - (i % 3))
|
||||
got = (r.phase, r.owns_setpoint, r.setpoint_w, r.events,
|
||||
m.store.get_time("last_completed"))
|
||||
same = same and got == want
|
||||
last = want[4]
|
||||
if r.phase == IDLE:
|
||||
end = t
|
||||
check(f"hold_min {hm}: every tick identical (phase, owns, W, events, "
|
||||
"last_completed)", same)
|
||||
check("...ends at hold_min, last_completed = that tick, one COMPLETE line",
|
||||
end == H0 + hm * MIN and m.store.get_time("last_completed") == end
|
||||
and m.phase == IDLE)
|
||||
|
||||
m = in_hold()
|
||||
res, _, out, ev = run(m, H0, HOLD_MIN + 5, 100.0)
|
||||
check("HOLD with a reading: 0 W until the end, then IDLE at hold_min",
|
||||
out is not None and out[1] == H0 + HOLD_MIN * MIN and out[0].phase == IDLE)
|
||||
check("...last_completed is that tick and the COMPLETE line is said once",
|
||||
m.store.get_time("last_completed") == H0 + HOLD_MIN * MIN
|
||||
and ev == ["maintenance: cycle COMPLETE (120 min hold) "
|
||||
"- handing back to the loop"])
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED:")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
sys.exit(1)
|
||||
print("all ok")
|
||||
@@ -1469,8 +1469,11 @@ _info = [r.getMessage() for r in _out if r.levelno == logging.INFO]
|
||||
check(f"a Home Assistant restart is one plain WARNING line, and one INFO line "
|
||||
f"when both connections are back ({_warn}, {_info})",
|
||||
_warn[:1] == ["Home Assistant is not answering (error 502), perhaps it "
|
||||
"is restarting. The add-on keeps trying."]
|
||||
and _info == ["Home Assistant answers again."] and len(_warn) == 2)
|
||||
"is still starting. Control waits and resumes by itself."]
|
||||
and len(_info) == 1
|
||||
and re.fullmatch(r"Home Assistant answers again after \d+ seconds\.",
|
||||
_info[0]) is not None and len(_warn) == 2)
|
||||
# SAFETY-112's reminder and its timing are graded in test_safety112.py.
|
||||
check("...and the library's own text is kept, at DEBUG",
|
||||
any("Received message 8:1000" in r.getMessage() for r in _out
|
||||
if r.levelno == logging.DEBUG)
|
||||
|
||||
@@ -113,19 +113,21 @@ check("the harness bites: Leftover solar grid-charging with no plan moves "
|
||||
lambda: setattr(modetrade, "GRID_CHARGE_MODES",
|
||||
(packmode.LEFTOVER_SOLAR, packmode.CHEAP_HOURS)),
|
||||
lambda: setattr(modetrade, "GRID_CHARGE_MODES", _gcm)))
|
||||
_read = solarfc.read
|
||||
# OPT-17: the controller reads through `read_sum()`, so that is the seam.
|
||||
_read = solarfc.read_sum
|
||||
|
||||
|
||||
def _as_dark(today, tomorrow, now, **kw):
|
||||
return _read({"state": "0", "attributes": {"unit_of_measurement":
|
||||
"kWh"},
|
||||
"last_updated": now.isoformat()}, None, now)
|
||||
return _read([("sensor.f", {"state": "0", "attributes": {
|
||||
"unit_of_measurement": "kWh"}, "last_updated": now.isoformat()})],
|
||||
[], now)
|
||||
|
||||
|
||||
check("...and an unavailable forecast read as a dark one moves "
|
||||
"n2_sf_ls_fc_down (Leftover solar would buy its shortfall)",
|
||||
_moved("n2_sf_ls_fc_down", lambda: setattr(solarfc, "read", _as_dark),
|
||||
lambda: setattr(solarfc, "read", _read)))
|
||||
_moved("n2_sf_ls_fc_down",
|
||||
lambda: setattr(solarfc, "read_sum", _as_dark),
|
||||
lambda: setattr(solarfc, "read_sum", _read)))
|
||||
|
||||
# ============================================================================ #
|
||||
print("2. the forecast sensors")
|
||||
|
||||
@@ -0,0 +1,498 @@
|
||||
"""Runnable check for OPT-17, the solar forecast summed from several entities.
|
||||
`python3 test_opt17.py`
|
||||
|
||||
1. `solarfc.read_sum()`: sums in mixed units, refusals, a member down or
|
||||
stale makes that day unusable (never a partial sum), hourly splits, today
|
||||
and tomorrow, an empty list, and one member equal to `read()`.
|
||||
2. `solarfc.entities()`: which key a day uses.
|
||||
3. Options: the validator, the settings notes and config.yaml.
|
||||
4. The REAL controller (tools/opt11p3_replay.py): a one-member list runs
|
||||
exactly like the single key, two halves like one whole, a member down
|
||||
like a forecast down; the status row and the action log name the member
|
||||
once; every member is read in one gather; modes off reads nothing.
|
||||
|
||||
DECISIONS/OPT-17-several-forecast-entities.md has the rules. Mutations
|
||||
(MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import logging
|
||||
import os
|
||||
import re
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11p3_replay as rp # noqa: E402
|
||||
from app import (dayplan, homeview, messages, solarfc, uitext, # noqa: E402
|
||||
validate)
|
||||
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
L = timezone(timedelta(hours=2))
|
||||
UTC0 = datetime(2026, 9, 21, tzinfo=L).astimezone(timezone.utc)
|
||||
TOM = UTC0 + timedelta(days=1)
|
||||
NOW = datetime(2026, 9, 21, 9, 0, tzinfo=L).astimezone(timezone.utc)
|
||||
END = UTC0 + timedelta(days=1)
|
||||
OLD = NOW - timedelta(seconds=solarfc.FRESH_S + 1)
|
||||
|
||||
|
||||
def st(state, unit="kWh", at=NOW, **attrs):
|
||||
a = dict(attrs)
|
||||
if unit is not None:
|
||||
a["unit_of_measurement"] = unit
|
||||
return {"state": state, "attributes": a,
|
||||
"last_updated": at.isoformat(), "last_reported": at.isoformat()}
|
||||
|
||||
|
||||
def members(*states):
|
||||
return [(f"sensor.fc_{i}", s) for i, s in enumerate(states, 1)]
|
||||
|
||||
|
||||
def near(a, b, eps=1e-6):
|
||||
return a is not None and b is not None and abs(a - b) < eps
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. read_sum")
|
||||
fc, why, gaps = solarfc.read_sum(members(st("5"), st("7500", "Wh")), [], NOW)
|
||||
check("two members, kWh + Wh: 5 + 7.5 = 12.5 kWh",
|
||||
fc is not None and near(fc.today.kwh, 12.5) and why is None
|
||||
and gaps == ())
|
||||
check("...and the rest of the day adds up to the sum",
|
||||
near(fc.between(NOW, END), 12.5))
|
||||
fc, why, gaps = solarfc.read_sum(
|
||||
members(st("5"), st("2500", "Wh"), st("0.005", "MWh")), [], NOW)
|
||||
check("three members, kWh + Wh + MWh: 5 + 2.5 + 5 = 12.5 kWh",
|
||||
fc is not None and near(fc.today.kwh, 12.5))
|
||||
for unit in ("W", None, "kW", "%"):
|
||||
fc, why, gaps = solarfc.read_sum(members(st("5"), st("5", unit)), [],
|
||||
NOW)
|
||||
check(f"a member in {unit or 'no unit'} makes today unusable (unit), "
|
||||
f"and is named",
|
||||
fc is None and why == solarfc.UNIT
|
||||
and gaps == (("today", 2, "sensor.fc_2", solarfc.UNIT),))
|
||||
for bad, w in (("unavailable", solarfc.MISSING), ("unknown", solarfc.MISSING),
|
||||
(None, solarfc.MISSING), ("-1", solarfc.BAD),
|
||||
("lots", solarfc.BAD)):
|
||||
s2 = None if bad is None else st(bad)
|
||||
fc, why, gaps = solarfc.read_sum(members(st("5"), s2, st("4")), [], NOW)
|
||||
check(f"a member that reads {bad!r}: no forecast at all ({w}), not "
|
||||
f"the 9 kWh of the others",
|
||||
fc is None and why == w
|
||||
and gaps == (("today", 2, "sensor.fc_2", w),))
|
||||
fc, why, gaps = solarfc.read_sum(members(st("5"), st("4", at=OLD)), [], NOW)
|
||||
check("a stale member (older than 3 h): no forecast (stale), named",
|
||||
fc is None and why == solarfc.STALE
|
||||
and gaps == (("today", 2, "sensor.fc_2", solarfc.STALE),))
|
||||
EVE = datetime(2026, 9, 20, 23, 30, tzinfo=L).astimezone(timezone.utc)
|
||||
MID = datetime(2026, 9, 21, 0, 10, tzinfo=L).astimezone(timezone.utc)
|
||||
fc, why, gaps = solarfc.read_sum(members(st("5", at=MID), st("0", at=EVE)),
|
||||
[], MID)
|
||||
check("a member from before local midnight is stale, not a dark member",
|
||||
fc is None and why == solarfc.STALE)
|
||||
fc, why, gaps = solarfc.read_sum(members(st("unavailable"), st("4", at=OLD)),
|
||||
[], NOW)
|
||||
check("two members down: both named, the first reason is the day's",
|
||||
fc is None and why == solarfc.MISSING and [g[1] for g in gaps] == [1, 2])
|
||||
check("an empty list is not set", solarfc.read_sum([], [], NOW)
|
||||
== (None, solarfc.NOT_SET, ())
|
||||
and solarfc.read_sum([], members(st("5")), NOW)[1] == solarfc.NOT_SET)
|
||||
fc, _w, _g = solarfc.read_sum(members(st("5", at=NOW - timedelta(hours=2)),
|
||||
st("4")), [], NOW)
|
||||
check("the forecast's time is the oldest member's report",
|
||||
fc.at == NOW - timedelta(hours=2))
|
||||
|
||||
# Tomorrow.
|
||||
fc, why, gaps = solarfc.read_sum(members(st("5"), st("4")),
|
||||
members(st("12"), st("8000", "Wh")), NOW)
|
||||
check("tomorrow: 12 + 8 = 20 kWh, and today is 9",
|
||||
fc is not None and near(fc.tomorrow.kwh, 20.0) and near(fc.today.kwh,
|
||||
9.0)
|
||||
and near(fc.between(TOM, TOM + timedelta(days=1)), 20.0))
|
||||
for name, t2, w in (("unavailable", st("unavailable"), solarfc.MISSING),
|
||||
("stale", st("8", at=OLD), solarfc.STALE),
|
||||
("in W", st("8", "W"), solarfc.UNIT)):
|
||||
fc, why, gaps = solarfc.read_sum(members(st("5"), st("4")),
|
||||
members(st("12"), t2), NOW)
|
||||
check(f"a tomorrow member {name}: tomorrow is not used (not 12 kWh), "
|
||||
f"today is kept, the member is named",
|
||||
fc is not None and fc.tomorrow is None and near(fc.today.kwh, 9.0)
|
||||
and why is None
|
||||
and gaps == (("tomorrow", 2, "sensor.fc_2", w),)
|
||||
and fc.between(NOW, TOM + timedelta(hours=9)) is None)
|
||||
fc, _w, gaps = solarfc.read_sum(members(st("5"), st("4")), [], NOW)
|
||||
check("no tomorrow list: today only, nothing named",
|
||||
fc.tomorrow is None and gaps == ())
|
||||
|
||||
# Hourly splits.
|
||||
sol = [{"period_start": (UTC0 + timedelta(minutes=30 * i)).isoformat(),
|
||||
"pv_estimate": 2.0 if 20 <= i < 36 else 0.0} for i in range(48)]
|
||||
wh = {(UTC0 + timedelta(hours=h)).isoformat(): (1000.0 if 8 <= h < 16
|
||||
else 0.0)
|
||||
for h in range(24)}
|
||||
fc, _w, _g = solarfc.read_sum(members(st("8.0", detailedForecast=sol),
|
||||
st("7.0", wh_period=wh)), [], NOW)
|
||||
one_s = solarfc.read(st("8.0", detailedForecast=sol), None, NOW)[0]
|
||||
one_w = solarfc.read(st("7.0", wh_period=wh), None, NOW)[0]
|
||||
spans = [(NOW, END)] + [
|
||||
(datetime(2026, 9, 21, h, tzinfo=L), datetime(2026, 9, 21, h + 1,
|
||||
tzinfo=L))
|
||||
for h in range(9, 20)]
|
||||
check("every member has a split: the splits are merged (hour by hour, the "
|
||||
"sum of each member's own split)",
|
||||
fc.today.periods and near(fc.today.kwh, 15.0)
|
||||
and all(near(fc.between(a, b), one_s.between(a, b)
|
||||
+ one_w.between(a, b)) for a, b in spans))
|
||||
check("...so 10:00-12:00 is 2 (Solcast) + 2 (Open-Meteo) = 4 kWh",
|
||||
near(fc.between(datetime(2026, 9, 21, 10, tzinfo=L),
|
||||
datetime(2026, 9, 21, 12, tzinfo=L)), 4.0))
|
||||
fc, _w, _g = solarfc.read_sum(members(st("8.0", detailedForecast=sol),
|
||||
st("7.0")), [], NOW)
|
||||
bell = solarfc.read(st("15.0"), None, NOW)[0]
|
||||
check("one member without a split: the sum goes on the bell, as one "
|
||||
"state-only sensor of 15 kWh would",
|
||||
fc.today.periods == () and near(fc.today.kwh, 15.0)
|
||||
and all(near(fc.between(a, b), bell.between(a, b)) for a, b in spans))
|
||||
wht = {(TOM + timedelta(hours=h)).isoformat(): (500.0 if 8 <= h < 16 else 0)
|
||||
for h in range(24)}
|
||||
fc, _w, _g = solarfc.read_sum(members(st("5")),
|
||||
members(st("4", wh_period=wht),
|
||||
st("4", wh_period=wht)), NOW)
|
||||
check("tomorrow's splits are merged too (8 x 0.5 kWh each, 8 in all)",
|
||||
fc.tomorrow.periods and near(fc.between(TOM, TOM + timedelta(days=1)),
|
||||
8.0)
|
||||
and near(fc.between(TOM + timedelta(hours=8),
|
||||
TOM + timedelta(hours=10)), 2.0))
|
||||
fc, _w, _g = solarfc.read_sum(members(st("5")),
|
||||
members(st("4", wh_period=wht), st("4")), NOW)
|
||||
check("...and fall back to the bell when one has none",
|
||||
fc.tomorrow.periods == () and near(fc.tomorrow.kwh, 8.0))
|
||||
|
||||
# One member is read().
|
||||
TODAYS = [st("12.5"), st("12500", "Wh"), st("0.0125", "MWh"), st("12.5", "W"),
|
||||
st("12.5", None), st("unavailable"), st("unknown"), None, st("-1"),
|
||||
st("lots"), st("12.5", at=OLD), st("12.5", at=NOW + timedelta(
|
||||
hours=1)), st("8.0", detailedForecast=sol),
|
||||
st("7.0", wh_period=wh), st("0")]
|
||||
TOMS = [None, st("20"), st("20", at=OLD), st("unavailable"), st("20", "W"),
|
||||
st("4", wh_period=wht)]
|
||||
WHENS = [NOW, MID, datetime(2026, 9, 21, 19, 30, tzinfo=L)]
|
||||
same, n = True, 0
|
||||
for now in WHENS:
|
||||
for a in TODAYS:
|
||||
for b in TOMS:
|
||||
n += 1
|
||||
one = solarfc.read(a, b, now)
|
||||
got = solarfc.read_sum([("sensor.f", a)],
|
||||
[("sensor.t", b)] if b is not None
|
||||
else [], now)
|
||||
same = same and got[:2] == one
|
||||
check(f"one member per day gives exactly what read() gives ({n} cases: "
|
||||
f"units, refusals, stale, splits, tomorrow)", same and n == 270)
|
||||
|
||||
# ============================================================================ #
|
||||
print("2. entities")
|
||||
E = solarfc.entities
|
||||
check("the single key alone", E({"pv_forecast_entity": "sensor.a"})
|
||||
== ("sensor.a",))
|
||||
check("the list alone, in order", E({"pv_forecast_entities": [
|
||||
"sensor.b", "sensor.a"]}) == ("sensor.b", "sensor.a"))
|
||||
check("a list with an entry replaces the single key",
|
||||
E({"pv_forecast_entity": "sensor.a",
|
||||
"pv_forecast_entities": ["sensor.b"]}) == ("sensor.b",))
|
||||
check("an empty list or blank rows use the single key",
|
||||
E({"pv_forecast_entity": "sensor.a", "pv_forecast_entities": []})
|
||||
== ("sensor.a",)
|
||||
and E({"pv_forecast_entity": "sensor.a",
|
||||
"pv_forecast_entities": ["", " "]}) == ("sensor.a",))
|
||||
check("a repeated id counts once (it would double that forecast)",
|
||||
E({"pv_forecast_entities": ["sensor.a", "sensor.b", "sensor.a"]})
|
||||
== ("sensor.a", "sensor.b"))
|
||||
check("tomorrow reads its own keys",
|
||||
E({"pv_forecast_entities": ["sensor.a"],
|
||||
"pv_forecast_tomorrow_entities": ["sensor.t1", "sensor.t2"]},
|
||||
tomorrow=True) == ("sensor.t1", "sensor.t2")
|
||||
and E({"pv_forecast_tomorrow_entity": "sensor.t"}, tomorrow=True)
|
||||
== ("sensor.t",))
|
||||
check("nothing set: ()", E({}) == () and E({}, tomorrow=True) == ())
|
||||
|
||||
# ============================================================================ #
|
||||
print("3. options")
|
||||
F = validate._forecast_problems
|
||||
for one, many in (solarfc.TODAY_KEYS, solarfc.TOMORROW_KEYS):
|
||||
p = F({one: "sensor.a", many: ["sensor.b", "sensor.c"]})
|
||||
check(f"{one} and {many} both set: refused, one plain message that "
|
||||
f"says which to keep",
|
||||
len(p) == 1 and "not both" in p[0] and "Keep the list" in p[0]
|
||||
and one in p[0] and many in p[0] and len(p[0].split()) <= 30)
|
||||
check(f"...{many} alone is fine, and so is {one} alone",
|
||||
not F({many: ["sensor.b", "sensor.c"]}) and not F({one: "sensor.a"})
|
||||
and not F({one: "sensor.a", many: []})
|
||||
and not F({one: "", many: ["sensor.b"]}))
|
||||
check(f"...blank rows in {many} are ignored, alone or beside {one}",
|
||||
not F({many: ["", None, "sensor.b"]})
|
||||
and not F({one: "sensor.a", many: ["", None]}))
|
||||
p = F({many: ["sensor.b", "number.x"]})
|
||||
check(f"...an entry in {many} that is not a sensor is refused",
|
||||
len(p) == 1 and "only sensors" in p[0] and "number.x" in p[0])
|
||||
check(f"...and {many} that is not a list is refused",
|
||||
F({many: "sensor.b"}) and "list of sensors" in F({many: "x"})[0])
|
||||
with open(os.path.join(HERE, "translations", "en.yaml"),
|
||||
encoding="utf-8") as fh:
|
||||
EN = fh.read()
|
||||
for k in solarfc.TODAY_KEYS + solarfc.TOMORROW_KEYS:
|
||||
name = re.search(rf"^ {k}:\n name: \"Hardware · ([^\"(]+?)"
|
||||
rf"(?: \(kWh\))?\"$", EN, re.M)
|
||||
check(f"the refusal names {k} by its label on the tab",
|
||||
name is not None
|
||||
and f"“{name.group(1)}” ({k})" in validate.S(k))
|
||||
print(" " + F({"pv_forecast_entity": "sensor.a",
|
||||
"pv_forecast_entities": ["sensor.b"]})[0])
|
||||
VBASE = {"setpoint_entity": "number.goodwe_setpoint", "max_w": 2000,
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "maintenance_charge_w": 2000,
|
||||
"maintenance_discharge_w": 2000, "battery_modes_enabled": True}
|
||||
check("the start-up check refuses both keys set for a day",
|
||||
any("not both" in p for p in validate.validate_startup_config(
|
||||
dict(VBASE, pv_forecast_tomorrow_entity="sensor.a",
|
||||
pv_forecast_tomorrow_entities=["sensor.b"])))
|
||||
and validate.validate_startup_config(
|
||||
dict(VBASE, pv_forecast_entities=["sensor.a", "sensor.b"],
|
||||
pv_forecast_tomorrow_entities=["sensor.c", "sensor.d"]))
|
||||
== [])
|
||||
notes = []
|
||||
validate._entity_notes(notes, dict(VBASE, pv_forecast_entities=[
|
||||
"sensor.a", "sensor.b", "sensor.gone"]),
|
||||
{"sensor.a": {"unit": "kWh"}, "sensor.b": {"unit": "W"}})
|
||||
check("settings notes: a listed sensor not in kWh, and one Home Assistant "
|
||||
"does not have, are each named",
|
||||
any("sensor.b" in n.text and "kWh" in n.text for n in notes)
|
||||
and any("sensor.gone" in n.text for n in notes)
|
||||
and not any("sensor.a " in n.text for n in notes))
|
||||
notes = []
|
||||
validate._entity_notes(notes, dict(VBASE, pv_forecast_tomorrow_entities=[
|
||||
"sensor.t"]), {"sensor.t": {"unit": "kWh"}})
|
||||
check("a tomorrow list without today's forecast gets the same warning as "
|
||||
"the single key", any("used only with today's" in n.text
|
||||
for n in notes))
|
||||
notes = []
|
||||
validate._entity_notes(notes, {"pv_forecast_entities": ["sensor.a"]},
|
||||
{"sensor.a": {"unit": "kWh"}})
|
||||
check("a list with battery modes off gets the 'unused' note",
|
||||
any("battery modes on" in n.text for n in notes))
|
||||
with open(os.path.join(HERE, "config.yaml"), encoding="utf-8") as fh:
|
||||
CFG = fh.read()
|
||||
for k in ("pv_forecast_entities", "pv_forecast_tomorrow_entities"):
|
||||
check(f"config.yaml: {k} defaults to [] (load-bearing) and is a list "
|
||||
f"of str",
|
||||
re.search(rf"^ {k}: \[\]$", CFG, re.M) is not None
|
||||
and re.search(rf"^ {k}:\n - str$", CFG, re.M) is not None)
|
||||
for k in solarfc.TODAY_KEYS[:1] + solarfc.TOMORROW_KEYS[:1]:
|
||||
check(f"config.yaml: {k} is unchanged (str?, default \"\")",
|
||||
re.search(rf"^ {k}: \"\"$", CFG, re.M) is not None
|
||||
and re.search(rf"^ {k}: str\?$", CFG, re.M) is not None)
|
||||
|
||||
# ============================================================================ #
|
||||
print("4. the real controller")
|
||||
A, B = "inverter-a", "inverter-b"
|
||||
# Prices as in test_modes_p4: cheap 01:00-03:00, dear 19:00-20:00 local.
|
||||
DAYW = [0.20] * 96 * 2
|
||||
for i in list(range(4, 12)) + list(range(100, 108)):
|
||||
DAYW[i] = 0.02
|
||||
for i in list(range(76, 80)) + list(range(172, 176)):
|
||||
DAYW[i] = 0.40
|
||||
WPTS = [(UTC0 + timedelta(minutes=15 * i), 900, p)
|
||||
for i, p in enumerate(DAYW)]
|
||||
SF_LS = {"a": (True, "solar_first", False),
|
||||
"b": (True, "leftover_solar", False)}
|
||||
# Each fake sensor: (share of the day's sun, has a split, status).
|
||||
SENSORS = {}
|
||||
FC_KWH = [1.0]
|
||||
START = [UTC0]
|
||||
CALLS = []
|
||||
|
||||
|
||||
async def _sensor(self, e):
|
||||
CALLS.append(("start", e))
|
||||
await asyncio.sleep(0)
|
||||
CALLS.append(("end", e))
|
||||
now = START[0] + timedelta(seconds=self.t)
|
||||
share, split, status = SENSORS[e]
|
||||
if status == "down":
|
||||
return {"state": "unavailable", "attributes": {},
|
||||
"last_updated": now.isoformat()}
|
||||
at = now - timedelta(hours=4) if status == "stale" else now
|
||||
loc = now.astimezone(L)
|
||||
d0 = loc.replace(hour=0, minute=0, second=0, microsecond=0)
|
||||
if e.startswith("sensor.tom"):
|
||||
d0 += timedelta(days=1)
|
||||
wh = {(d0 + timedelta(hours=h)).astimezone(timezone.utc).isoformat():
|
||||
(FC_KWH[0] * 100.0 * share if 8 <= h < 18 else 0.0)
|
||||
for h in range(24)}
|
||||
left = sum(v for k, v in wh.items()
|
||||
if datetime.fromisoformat(k) >= now) / 1000.0
|
||||
attrs = {"unit_of_measurement": "kWh"}
|
||||
if split:
|
||||
attrs["wh_period"] = wh
|
||||
return {"state": f"{left:.6f}", "attributes": attrs,
|
||||
"last_updated": at.isoformat(), "last_reported": at.isoformat()}
|
||||
|
||||
|
||||
rp.Hass.state = _sensor
|
||||
|
||||
|
||||
def seed(c):
|
||||
if c.house_profile is not None:
|
||||
hp = dayplan.HouseProfile()
|
||||
t = UTC0 - timedelta(days=1)
|
||||
while t < UTC0:
|
||||
h = t.astimezone(L).hour
|
||||
hp.add(t, 3000.0 if 17 <= h < 22 else 600.0)
|
||||
t += timedelta(seconds=5)
|
||||
hp.add(t, None)
|
||||
c.house_profile = hp
|
||||
|
||||
|
||||
def run(opts, hours=4.0, modes=True):
|
||||
start = UTC0 + timedelta(hours=0.75)
|
||||
START[0] = start
|
||||
rows = []
|
||||
|
||||
def cb(c, h, now, pr):
|
||||
sh = dict(c.allocation.shares) if c.allocation is not None and \
|
||||
c.allocation.shares else {}
|
||||
rows.append((now, round(h.grid(), 6), tuple(sorted(sh.items())),
|
||||
getattr(c.arb, "action", None),
|
||||
tuple(sorted(c.mode_tick.roles.items()))
|
||||
if c.mode_tick else (),
|
||||
tuple(sorted((u, round(p.soc, 6))
|
||||
for u, p in h.plants.items())),
|
||||
tuple(sorted((c.plan_targets() or {}).items())),
|
||||
None if c.day_plan is None else c.day_plan.verdict))
|
||||
_st, c = rp.run("p3_ls" if modes else "modes_off", [(UTC0.timestamp()
|
||||
- 10, 800.0)],
|
||||
WPTS, start, 3600 * hours, check=cb,
|
||||
soc0={"a": 60.0, "b": 30.0}, choice=SF_LS,
|
||||
extra=dict({"cycle_cost_threshold_eur": 0.20}, **opts),
|
||||
patch=seed)
|
||||
return rows, c
|
||||
|
||||
|
||||
def fc_rows(c):
|
||||
return [r for r in c.checks() if r["id"] == "solar_forecast"]
|
||||
|
||||
|
||||
def fc_events(c):
|
||||
return [e for e in c.events if "solar forecast" in e]
|
||||
|
||||
|
||||
SENSORS.update({
|
||||
"sensor.all": (1.0, True, "ok"), "sensor.h1": (0.5, True, "ok"),
|
||||
"sensor.h2": (0.5, True, "ok"), "sensor.h2_flat": (0.5, False, "ok"),
|
||||
"sensor.down": (0.5, True, "down"), "sensor.stale": (0.5, True, "stale"),
|
||||
"sensor.tom_all": (1.0, True, "ok"), "sensor.tom_h1": (0.5, True, "ok"),
|
||||
"sensor.tom_down": (0.5, True, "down"), "sensor.none": (1.0, True, "down"),
|
||||
})
|
||||
single, c_single = run({"pv_forecast_entity": "sensor.all"})
|
||||
listed, c_listed = run({"pv_forecast_entities": ["sensor.all"]})
|
||||
plans = [r for r in single if r[6]]
|
||||
check(f"the run makes a day plan with a level ({len(plans)} of "
|
||||
f"{len(single)} cycles), so the forecast steers something",
|
||||
plans and any(r[7] is not None for r in single))
|
||||
check("a one-member list runs exactly like the single key: every grid "
|
||||
"figure, share, action, role, level and plan, cycle by cycle",
|
||||
single == listed and len(single) > 2000)
|
||||
check("...and says the same on the status page and in the action log",
|
||||
fc_rows(c_single) == fc_rows(c_listed) == []
|
||||
and fc_events(c_single) == fc_events(c_listed))
|
||||
halves, c_halves = run({"pv_forecast_entities": ["sensor.h1", "sensor.h2"]})
|
||||
check("two members of half the sun each run like one sensor of all of it",
|
||||
[r[:6] + (r[7],) for r in halves] == [r[:6] + (r[7],) for r in single]
|
||||
and all(len(a[6]) == len(b[6]) and all(
|
||||
k1 == k2 and abs(v1 - v2) < 1e-6 for (k1, v1), (k2, v2)
|
||||
in zip(a[6], b[6])) for a, b in zip(halves, single)))
|
||||
none_, c_none = run({"pv_forecast_entity": "sensor.none"})
|
||||
check("(the comparison bites: no forecast runs differently)",
|
||||
[r[:6] for r in none_] != [r[:6] for r in single])
|
||||
for name, mem in (("unavailable", "sensor.down"), ("stale", "sensor.stale")):
|
||||
rows, c = run({"pv_forecast_entities": ["sensor.h1", mem]})
|
||||
check(f"a member {name}: the controller runs exactly as with the single "
|
||||
f"forecast unavailable (no partial sum)", rows == none_)
|
||||
check(f"...the status page names it by place, in one short line",
|
||||
[r["text"] for r in fc_rows(c)] == [
|
||||
"Solar forecast for today: not used, source 2 of 2 has no "
|
||||
"reading"] and fc_rows(c)[0]["warn"])
|
||||
ev = fc_events(c)
|
||||
check(f"...and the action log names it once in {len(single)} cycles",
|
||||
len(ev) == 1 and mem in ev[0] and "today" in ev[0])
|
||||
one_down, c_one_down = run({"pv_forecast_entities": ["sensor.none"]})
|
||||
check("a one-member list that is down runs, shows and logs exactly like the "
|
||||
"single key down", one_down == none_
|
||||
and fc_rows(c_one_down) == fc_rows(c_none)
|
||||
and fc_events(c_one_down) == fc_events(c_none))
|
||||
# A forecast missing from the start logs nothing (the start state is
|
||||
# already "missing"); that is release/1.0's behaviour, kept.
|
||||
check("the single key down: no new row and no new log line",
|
||||
fc_rows(c_none) == [] and fc_events(c_none) == [])
|
||||
CALLS.clear()
|
||||
rows, c = run({"pv_forecast_entities": ["sensor.h1", "sensor.h2"],
|
||||
"pv_forecast_tomorrow_entities": ["sensor.tom_h1",
|
||||
"sensor.tom_down"]},
|
||||
hours=0.2)
|
||||
check("a tomorrow member down: today is used, tomorrow is not, and the row "
|
||||
"says so",
|
||||
c.solar_fc is not None and c.solar_fc.tomorrow is None
|
||||
and [r["text"] for r in fc_rows(c)] == [
|
||||
"Solar forecast for tomorrow: not used, source 2 of 2 has no "
|
||||
"reading"]
|
||||
and len(fc_events(c)) == 1 and "sensor.tom_down" in fc_events(c)[0])
|
||||
check("...and the page hint says tomorrow's forecast is not used",
|
||||
(c.hint or "").endswith(messages.hint("forecast_no_tomorrow")))
|
||||
check("...and Home titles the row as the solar forecast, in EN and NL",
|
||||
[a["title"] for a in homeview.attention(fc_rows(c))]
|
||||
== ["Solar forecast"]
|
||||
and uitext.words("nl")["home_words"]["attn"]["solar_forecast"]
|
||||
== "Zonneprognose")
|
||||
first = CALLS[:8]
|
||||
check("every member of both days is read in one gather (all four start "
|
||||
"before any ends)",
|
||||
[k for k, _e in first] == ["start"] * 4 + ["end"] * 4
|
||||
and sorted(e for _k, e in first[:4]) == sorted(
|
||||
["sensor.h1", "sensor.h2", "sensor.tom_h1", "sensor.tom_down"]))
|
||||
rows, c = run({"pv_forecast_entities": ["sensor.h1"],
|
||||
"pv_forecast_tomorrow_entities": ["sensor.tom_all"]},
|
||||
hours=0.2)
|
||||
check("tomorrow: a one-member list is read and counted",
|
||||
c.solar_fc is not None and c.solar_fc.tomorrow is not None)
|
||||
rows, c = run({"pv_forecast_entities": ["sensor.h1", "sensor.h2_flat"]},
|
||||
hours=0.2)
|
||||
check("a member without a split: the controller's forecast is on the bell",
|
||||
c.solar_fc is not None and c.solar_fc.today.periods == ())
|
||||
CALLS.clear()
|
||||
run({"pv_forecast_entities": ["sensor.h1", "sensor.h2"]}, hours=0.2,
|
||||
modes=False)
|
||||
check("battery modes off: no forecast member is read", CALLS == [])
|
||||
check("the status row is a STYLE status row (<= 15 words, no entity id)",
|
||||
all(len(t.split()) <= 15 and "sensor." not in t for t in (
|
||||
messages.row_forecast_gap("today", [2, 3], 3),
|
||||
messages.row_forecast_gap("tomorrow", [1], 2))))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"FAILED: {len(fails)}")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
@@ -0,0 +1,307 @@
|
||||
"""Runnable check for SAFETY-107: a refusal held while another writer has the
|
||||
wire is learned once. `python3 test_safety107.py`
|
||||
|
||||
A full pack under a maintenance charge in a cheap window took no charge. At
|
||||
one inverter SAFETY-52's "another writer" end then fired every cycle, and
|
||||
compute() learned the refusal again in the same cycle: "BATTERY REFUSES" and
|
||||
"BATTERY REFUSES ENDED: another writer" each second on the rig (MAINT-13 F5).
|
||||
Now another writer ends a refusal only if compute(), judging it afresh
|
||||
against that writer's ask, no longer finds it. DECISIONS/SAFETY-107.
|
||||
|
||||
Drives the REAL Controller (read_inputs + cycle) on opt11_identity's rig.
|
||||
1. The card's case: 15 min of a full pack under a maintenance charge, N=1
|
||||
and N=2, at a 1, 2 and 5 s meter: at most 2 refusal lines, held throughout.
|
||||
2. Other writers: a trade and the peak guard over a battery that gives
|
||||
nothing. One episode each, no flap.
|
||||
3. A refusal still ends: a different writer really takes over, the battery
|
||||
delivers again, a writer asks the other way, stop. The probe clock.
|
||||
|
||||
4. Not covered, pinned: a perfectly flat reading under a writer.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in DECISIONS/SAFETY-107.
|
||||
"""
|
||||
|
||||
import functools
|
||||
import logging
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety79_identity as s79 # noqa: E402
|
||||
import app.main as app_main # noqa: E402
|
||||
from app import control # noqa: E402
|
||||
from app.arbiter import Claim, P_ARBITRAGE # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from named_absence import nth, present # noqa: E402
|
||||
|
||||
fails = []
|
||||
QUARTER = 900.0
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def run(n=1, *, plant, house, dur=QUARTER, tick=5.0, maint=True,
|
||||
cheap=lambda c, t: True, trade=lambda t: None, p1=False, cap=2500,
|
||||
auto=lambda t: True):
|
||||
"""Rows (t, commands, site target, loop reason, refused, refused_at,
|
||||
unit refusals) and every action-log line as (t, line, hint).
|
||||
|
||||
`plant(u, t, cmd)` is battery u's reading. `cheap(c, t)` opens the cheap
|
||||
window. `trade(t)` is a SET claim at P_ARBITRAGE added to the claim list
|
||||
(a writer above the loop), or None."""
|
||||
log, rows, now = [], [], [0.0]
|
||||
real_power, real_tick = rig._Hass.power, rig.TICK
|
||||
real_log, real_resolve, real_c = (Controller.log_event, app_main.resolve,
|
||||
rig.Controller)
|
||||
|
||||
def power(self, u):
|
||||
return float(plant(u, self.t, self.cmd[u]))
|
||||
|
||||
def log_event(self, msg, hint=None):
|
||||
log.append((now[0], msg, hint))
|
||||
return real_log(self, msg, hint)
|
||||
|
||||
def resolve(claims, **kw):
|
||||
v = trade(now[0])
|
||||
if v is not None:
|
||||
claims.append(Claim.set("arbitrage", P_ARBITRAGE, v, "trade"))
|
||||
return real_resolve(claims, **kw)
|
||||
|
||||
def before(c, t):
|
||||
now[0] = t
|
||||
if not getattr(c.hass, "_s107", False):
|
||||
read = c.hass.number
|
||||
|
||||
async def number(e, invert=False):
|
||||
if e == "sensor.pnow":
|
||||
return 0.05 if cheap(c, c.hass.t) else 0.30
|
||||
if e == "sensor.pavg":
|
||||
return 0.20
|
||||
return await read(e, invert)
|
||||
c.hass.number, c.hass._s107 = number, True
|
||||
if p1:
|
||||
s79._feed(c, t)
|
||||
c.auto = auto(t)
|
||||
|
||||
def on_cycle(c, t):
|
||||
rows.append((t, tuple(c.hass.cmd[u] for u in "ab"[:n]), c.target,
|
||||
c.loop_reason, c.batt_refused, c.batt_refused_at,
|
||||
tuple(i.refused for i in c.inverters)))
|
||||
|
||||
extra = {"price_now_entity": "sensor.pnow",
|
||||
"price_avg_entity": "sensor.pavg"}
|
||||
if maint:
|
||||
extra.update({"maintenance_enabled": True,
|
||||
"maintenance_start_hour": 11,
|
||||
"maintenance_charge_w": 2000})
|
||||
if p1:
|
||||
extra.update(s79.P1, peak_cap_w=cap)
|
||||
db = os.path.join(tempfile.mkdtemp(prefix="s107-"), "tariff.db")
|
||||
rig._Hass.power, rig.TICK = power, tick
|
||||
Controller.log_event, app_main.resolve = log_event, resolve
|
||||
rig.Controller = functools.partial(real_c, peak_db_path=db)
|
||||
try:
|
||||
_, c = rig.run(n, extra=extra, dur=dur, load=house,
|
||||
soc=lambda u, t: 50.0, cut=lambda u, t: False,
|
||||
before=before, on_cycle=on_cycle,
|
||||
store=s79.store_charging(n) if maint else rig._Store())
|
||||
finally:
|
||||
rig._Hass.power, rig.TICK = real_power, real_tick
|
||||
Controller.log_event, app_main.resolve = real_log, real_resolve
|
||||
rig.Controller = real_c
|
||||
return rows, log, c
|
||||
|
||||
|
||||
def full_a(u, t, cmd):
|
||||
"""A takes no charge (a full pack), its reading jittering by a few watts
|
||||
as a real one does; B follows."""
|
||||
return -1.0 - int(t) % 3 if u == "a" and cmd < 0 else round(cmd)
|
||||
|
||||
|
||||
def flat_a(u, t, cmd):
|
||||
"""`full_a` with a perfectly flat reading (the stale-reading gate trips)."""
|
||||
return -1.0 if u == "a" and cmd < 0 else round(cmd)
|
||||
|
||||
|
||||
def empty_a(u, t, cmd):
|
||||
"""A gives nothing (an empty pack), its reading jittering by a few watts
|
||||
(SAFETY-73's jitter shape, so the stale-reading gate stays out of it);
|
||||
B follows."""
|
||||
return -4.0 - int(t) % 3 if u == "a" and cmd >= -4.0 else round(cmd)
|
||||
|
||||
|
||||
def lines(log, word="REFUSES"):
|
||||
return [x for x in log if word in x[1]]
|
||||
|
||||
|
||||
def ends(log):
|
||||
return [x for x in log if "REFUSES ENDED" in x[1]]
|
||||
|
||||
|
||||
def refused(r):
|
||||
"""Row r holds a refusal (site at N=1, any unit at N>1)."""
|
||||
return bool(r[4]) or any(r[6])
|
||||
|
||||
|
||||
def held_from(rows):
|
||||
"""True when, once learned, the refusal is held on every later row."""
|
||||
first = next((k for k, r in enumerate(rows) if refused(r)), None)
|
||||
return first is not None and all(refused(r) for r in rows[first:])
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print("1. the card: a full pack under a maintenance charge, 15 min")
|
||||
# ==============================================================================
|
||||
for n, tick, house in ((n, k, h) for n in (1, 2) for k in (1.0, 2.0, 5.0)
|
||||
for h in (800.0, -1500.0)):
|
||||
rows, log, c = run(n, plant=full_a, house=lambda t: house, tick=tick)
|
||||
ref = lines(log)
|
||||
tag = f"N={n}, {tick:.0f} s meter, house {house:+.0f} W"
|
||||
print(f" {tag}: {len(ref)} refusal line(s): "
|
||||
+ " / ".join(x[1][:60] for x in ref))
|
||||
check(f"{tag}: at most 2 refusal lines in 15 min (rig: 548 + 548)",
|
||||
1 <= len(ref) <= 2)
|
||||
check(f"{tag}: no end line", not ends(log))
|
||||
check(f"{tag}: learned once and held to the end", held_from(rows))
|
||||
# N=1: the charge's ceiling stays on the wire. N=2: SAFETY-73 closes A
|
||||
# in the refused direction, as before.
|
||||
check(f"{tag}: still in its charge, the wire as before",
|
||||
c.maints[0].phase == "charge"
|
||||
and all(r[1][0] == (-2000.0 if n == 1 else 0.0)
|
||||
for r in rows[-10:]))
|
||||
# The hint under the buttons is set at most once for the refusal.
|
||||
check(f"{tag}: the refusal hint is set once",
|
||||
sum(1 for x in ref if x[2] is not None) == 1)
|
||||
|
||||
# The probe clock: while the charge holds the wire no probe is tried (the
|
||||
# loop's ask is not on the wire), so the action log stays quiet.
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0, dur=3600.0)
|
||||
check("N=1, an hour: still one line, no probe tried under the charge",
|
||||
len(lines(log)) == 1
|
||||
and not any(r[3] == control.PROBING for r in rows))
|
||||
|
||||
# ==============================================================================
|
||||
print("\n2. other writers: a trade and the peak guard, no flap")
|
||||
# ==============================================================================
|
||||
# A trade (a SET above the loop) asks a full pack to charge for 15 min.
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0, maint=False,
|
||||
trade=lambda t: -1500.0)
|
||||
print(f" trade into a full pack: {len(lines(log))} line(s)")
|
||||
check("a trade into a full pack: learned once, held, no end",
|
||||
len(lines(log)) == 1 and not ends(log) and held_from(rows))
|
||||
# The peak guard asks an empty pack to give while the house is over the limit.
|
||||
rows, log, c = run(1, plant=empty_a, house=lambda t: 4500.0, maint=False,
|
||||
p1=True)
|
||||
print(f" peak guard on an empty pack: {len(lines(log))} line(s), "
|
||||
f"guard floor {c.peak_guard.floor_w if c.peak_guard else None}")
|
||||
check("the peak guard on an empty pack: the guard holds the wire",
|
||||
c.peak_guard is not None and c.peak_guard.engaged)
|
||||
check("the peak guard on an empty pack: at most 2 lines, held to the end",
|
||||
1 <= len(lines(log)) <= 2 and held_from(rows))
|
||||
|
||||
# ==============================================================================
|
||||
print("\n3. a refusal still ends")
|
||||
# ==============================================================================
|
||||
# a. Learned by the loop on an empty pack; at 300 s a trade really takes the
|
||||
# wire and asks it to give 2000 W. The refusal was learned against the
|
||||
# loop's ask: it ends, then is learned against the trade, once.
|
||||
rows, log, _ = run(1, plant=empty_a, house=lambda t: 2000.0, maint=False,
|
||||
trade=lambda t: 2000.0 if 300.0 <= t < 900.0 else None,
|
||||
dur=1200.0)
|
||||
e = ends(log)
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
check("a different writer takes over: the refusal ends, 'another writer'",
|
||||
len(e) == 1 and "another writer" in e[0][1] and 300.0 < e[0][0] < 320.0)
|
||||
check("...and is learned again against the trade, once, and held",
|
||||
len(lines(log)) == 3 and held_from([r for r in rows if r[0] > 400.0]))
|
||||
check("...and the loop keeps it when the trade leaves (no line)",
|
||||
all(x[0] < 900.0 for x in lines(log)) and refused(nth(rows, -1)))
|
||||
# The writer asks the other way, which the empty pack takes.
|
||||
rows, log, _ = run(1, plant=empty_a, house=lambda t: 2000.0, maint=False,
|
||||
trade=lambda t: -1500.0 if t >= 300.0 else None)
|
||||
e = ends(log)
|
||||
check("a writer that asks the other way ends it ('another writer')",
|
||||
len(e) == 1 and "another writer" in e[0][1] and present(nth(rows, -1))
|
||||
and not refused(nth(rows, -1)))
|
||||
# b. The full pack starts taking charge again under the same writer.
|
||||
rows, log, _ = run(1, plant=lambda u, t, cmd: (
|
||||
round(cmd) if t >= 400.0 else full_a(u, t, cmd)), house=lambda t: 800.0)
|
||||
e = ends(log)
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
check("the battery takes charge again: the refusal ends once, on its reading",
|
||||
len(e) == 1 and "the battery gives power" in e[0][1]
|
||||
and 400.0 <= e[0][0] < 430.0 and present(nth(rows, -1))
|
||||
and not refused(nth(rows, -1)))
|
||||
# c. Stop and start still end it.
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0,
|
||||
auto=lambda t: not 500.0 <= t < 520.0)
|
||||
e = ends(log)
|
||||
check("stopping control still ends it", any("control stopped" in x[1]
|
||||
for x in e))
|
||||
# d. The probe clock. Learned under the charge; the cheap window closes when
|
||||
# the refusal is 910 s old, and the loop holds the wire (a surplus, so it
|
||||
# wants to charge). The first probe is a full PROBE_EVERY_S after the
|
||||
# window closed, as before: never at once.
|
||||
close = [None]
|
||||
|
||||
|
||||
def window(c, t):
|
||||
if close[0] is None and c.batt_refused:
|
||||
close[0] = t + 910.0
|
||||
return close[0] is None or t < close[0]
|
||||
|
||||
|
||||
rows, log, _ = run(1, plant=full_a, house=lambda t: -1500.0, cheap=window,
|
||||
dur=3000.0)
|
||||
probes = [r[0] for r in rows if r[3] == control.PROBING]
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
print(f" window closed at {close[0]} s, first probe at "
|
||||
f"{probes[0] if probes else None} s")
|
||||
check("the refusal carries over to the loop with no line",
|
||||
len(lines(log)) == 1 and held_from(rows))
|
||||
check("the first probe after the writer left comes PROBE_EVERY_S later",
|
||||
close[0] is not None and bool(probes)
|
||||
and probes[0] >= close[0] + control.PROBE_EVERY_S - 10.0)
|
||||
# e. A writer turns round on a dead pack with no gap. The evidence restarts
|
||||
# on the new sign (SAFETY-94), so the old refusal ends at once and the
|
||||
# other way is learned once, ~12 cycles later.
|
||||
rows, log, _ = run(1, plant=lambda u, t, cmd: (
|
||||
-2.0 - int(t) % 3 if u == "a" else round(cmd)), house=lambda t: 2000.0,
|
||||
maint=False, trade=lambda t: 2000.0 if t < 300.0 else -2000.0)
|
||||
e = ends(log)
|
||||
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
|
||||
check("a writer turns round on a dead pack: one end, then the other way",
|
||||
len(lines(log)) == 3 and len(e) == 1 and 300.0 < e[0][0] < 400.0
|
||||
and present(nth(rows, -1)) and nth(rows, -1)[4] == -1)
|
||||
|
||||
# ==============================================================================
|
||||
print("\n4. not covered: a perfectly flat reading under a writer")
|
||||
# ==============================================================================
|
||||
# The stale-reading gate trips on a flat reading while the command moves,
|
||||
# stops the site and seeds the refusal (SAFETY-52 decision 3). After the stop
|
||||
# the writer's ask comes back fresh, compute() has no saturation history
|
||||
# against it yet, so the refusal ends at the first cycle and the next trip
|
||||
# seeds it again: one pair per gate cycle, as on release/1.0 (the commands
|
||||
# are the same; DECISIONS/SAFETY-107 "Not covered"). Pinned so a change shows.
|
||||
rows, log, _ = run(1, plant=flat_a, house=lambda t: -1500.0)
|
||||
trips = len(lines(log, "STALE inverter"))
|
||||
print(f" flat reading, house -1500 W: {trips} gate trips, "
|
||||
f"{len(lines(log))} refusal lines in 15 min")
|
||||
check("flat reading: no per-cycle flap, at most one pair per gate trip",
|
||||
trips >= 1 and len(lines(log)) <= 2 * trips)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all SAFETY-107 checks passed")
|
||||
@@ -0,0 +1,440 @@
|
||||
"""SAFETY-112: waiting for Home Assistant to finish starting. `python3 -B test_safety112.py`
|
||||
|
||||
The Supervisor answers 502 to every add-on read, write and websocket until
|
||||
Home Assistant is RUNNING (DECISIONS/SAFETY-112-waiting-for-home-assistant.md),
|
||||
so the add-on cannot control then. This file grades what it says meanwhile:
|
||||
|
||||
1. The log: one WARNING when Home Assistant stops answering, one INFO line
|
||||
every 5 minutes while it stays down, one INFO line with the wait when it
|
||||
answers again. Only the API channel counts as "waiting": a 502 or a
|
||||
refused connection turns it on, the next good read off, a timeout never.
|
||||
2. The status page, N=1 and N=2: the waiting row is first and red, and is the
|
||||
banner. Home says "Waiting for Home Assistant" in English and Dutch, not
|
||||
"Needs you now", unless a safety stop outranks it. The page script has it.
|
||||
3. Control is unchanged: the same readings give the same writes with the
|
||||
waiting flag on or off, with 502 readings and with live ones.
|
||||
|
||||
Mutating a module this file grades? Read MUTATION.md first (purge __pycache__).
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import logging
|
||||
import os
|
||||
import re
|
||||
from types import SimpleNamespace
|
||||
|
||||
from app import hass as _hass
|
||||
from app import messages
|
||||
from app.main import Controller
|
||||
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
class _Rec(logging.Handler):
|
||||
def __init__(self):
|
||||
super().__init__(logging.DEBUG)
|
||||
self.records = []
|
||||
|
||||
def emit(self, record):
|
||||
self.records.append(record)
|
||||
|
||||
|
||||
def captured(fn):
|
||||
rec, lg = _Rec(), logging.getLogger("goodwe.hass")
|
||||
old = lg.level
|
||||
lg.addHandler(rec)
|
||||
lg.setLevel(logging.DEBUG)
|
||||
try:
|
||||
fn()
|
||||
finally:
|
||||
lg.removeHandler(rec)
|
||||
lg.setLevel(old)
|
||||
return [(r.levelno, r.getMessage()) for r in rec.records
|
||||
if r.levelno >= logging.INFO]
|
||||
|
||||
|
||||
class Clock:
|
||||
"""`hass.time` stand-in: only `monotonic` is read by Outage."""
|
||||
|
||||
def __init__(self):
|
||||
self.t = 1000.0
|
||||
|
||||
def monotonic(self):
|
||||
return self.t
|
||||
|
||||
|
||||
def with_clock(fn):
|
||||
clock, real = Clock(), _hass.time
|
||||
_hass.time = SimpleNamespace(monotonic=clock.monotonic)
|
||||
try:
|
||||
return fn(clock)
|
||||
finally:
|
||||
_hass.time = real
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("1. the log while Home Assistant does not answer")
|
||||
W, I = logging.WARNING, logging.INFO
|
||||
|
||||
|
||||
def outage(clock):
|
||||
o = _hass.Outage()
|
||||
o.down("api", "error 502", "read sensor.x: 502")
|
||||
for t in (1, 60, 299):
|
||||
clock.t = 1000 + t
|
||||
o.down("api", "error 502", "read sensor.x: 502")
|
||||
clock.t = 1300
|
||||
o.down("api", "error 502", "") # 5 minutes: the first reminder
|
||||
clock.t = 1301
|
||||
o.down("websocket", "the meter connection closed", "")
|
||||
clock.t = 1599
|
||||
o.down("api", "error 502", "") # 299 s after the reminder: none
|
||||
clock.t = 1600
|
||||
o.down("api", "error 502", "") # 10 minutes: the second
|
||||
clock.t = 1640
|
||||
o.up("api")
|
||||
o.up("websocket") # 640 s in all
|
||||
clock.t = 2000
|
||||
o.down("api", "no connection", "") # a new outage starts afresh
|
||||
clock.t = 2030
|
||||
o.up("api")
|
||||
|
||||
|
||||
lines = with_clock(lambda c: captured(lambda: outage(c)))
|
||||
check(f"one WARNING per outage, in plain words ({lines})",
|
||||
[m for lv, m in lines if lv == W] == [
|
||||
"Home Assistant is not answering (error 502), perhaps it is still "
|
||||
"starting. Control waits and resumes by itself.",
|
||||
"Home Assistant is not answering (no connection), perhaps it is "
|
||||
"still starting. Control waits and resumes by itself."])
|
||||
check("one 'still waiting' line per 5 minutes down, with the time so far",
|
||||
[m for lv, m in lines if lv == I and m.startswith("Still")] == [
|
||||
"Still waiting for Home Assistant to finish starting, 5 minutes "
|
||||
"so far.",
|
||||
"Still waiting for Home Assistant to finish starting, 10 minutes "
|
||||
"so far."])
|
||||
check("one INFO line when the last channel is back, with the wait, and a new "
|
||||
"outage counts from its own start",
|
||||
[m for lv, m in lines if lv == I and m.startswith("Home")] == [
|
||||
"Home Assistant answers again after 11 minutes.",
|
||||
"Home Assistant answers again after 30 seconds."])
|
||||
|
||||
|
||||
def channels(_clock):
|
||||
o = _hass.Outage()
|
||||
seen = [o.waiting()]
|
||||
o.down("websocket", "the meter connection closed", "")
|
||||
seen.append(o.waiting())
|
||||
o.down("api", "error 502", "")
|
||||
seen.append(o.waiting())
|
||||
o.up("websocket")
|
||||
seen.append(o.waiting())
|
||||
o.up("api")
|
||||
seen.append(o.waiting())
|
||||
return seen
|
||||
|
||||
|
||||
check("waiting() follows the API channel only, not the meter websocket",
|
||||
with_clock(channels) == [False, False, True, True, False])
|
||||
|
||||
|
||||
# The flag as `HomeAssistant.state()` sets it: a 502 or a refused connection
|
||||
# turns it on, the next good read turns it off, and a timeout (a slow Home
|
||||
# Assistant, not a starting one) leaves it alone.
|
||||
class _Answer:
|
||||
def __init__(self, what):
|
||||
self.what = what
|
||||
|
||||
async def __aenter__(self):
|
||||
if isinstance(self.what, BaseException):
|
||||
raise self.what
|
||||
return self
|
||||
|
||||
async def __aexit__(self, *_a):
|
||||
return False
|
||||
|
||||
@property
|
||||
def status(self):
|
||||
return self.what
|
||||
|
||||
def raise_for_status(self):
|
||||
pass
|
||||
|
||||
async def json(self):
|
||||
return {"state": "1"}
|
||||
|
||||
|
||||
class _Session:
|
||||
def __init__(self, answers):
|
||||
self.answers = list(answers)
|
||||
|
||||
def get(self, *_a, **_k):
|
||||
return _Answer(self.answers.pop(0))
|
||||
|
||||
|
||||
def reads(answers):
|
||||
async def go():
|
||||
real, _hass.OUTAGE = _hass.OUTAGE, _hass.Outage()
|
||||
lg = logging.getLogger("goodwe.hass")
|
||||
lg.disabled = True
|
||||
try:
|
||||
h = _hass.HomeAssistant(_Session(answers), token="t")
|
||||
seen = []
|
||||
for _ in answers:
|
||||
await h.state("sensor.x")
|
||||
seen.append(_hass.OUTAGE.waiting())
|
||||
return seen
|
||||
finally:
|
||||
_hass.OUTAGE = real
|
||||
lg.disabled = False
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
check("a 502 read turns waiting on and the next good read turns it off",
|
||||
reads([502, 200, 503, 404]) == [True, False, True, False])
|
||||
check("a refused connection is waiting too",
|
||||
reads([_hass.aiohttp.ClientConnectionError(), 200]) == [True, False])
|
||||
check("a read timeout is not waiting",
|
||||
reads([TimeoutError(), TimeoutError()]) == [False, False])
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("2. the status page, N=1 and N=2")
|
||||
|
||||
|
||||
class _Hass:
|
||||
session = None
|
||||
token = ""
|
||||
|
||||
def __init__(self):
|
||||
self.writes = []
|
||||
|
||||
async def limits(self, _e):
|
||||
return (-5000.0, 5000.0, 1.0)
|
||||
|
||||
async def number(self, _e, invert=False):
|
||||
return None # what a 502 read gives
|
||||
|
||||
async def state(self, _e):
|
||||
return None
|
||||
|
||||
async def set_number(self, e, v):
|
||||
self.writes.append((e, float(v)))
|
||||
return False # what a 502 write gives
|
||||
|
||||
async def call(self, *_a):
|
||||
return False
|
||||
|
||||
async def states(self):
|
||||
return None
|
||||
|
||||
|
||||
class _Store:
|
||||
def __init__(self):
|
||||
self.data = {}
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def get(self, k, d=None):
|
||||
return self.data.get(k, d)
|
||||
|
||||
def set_time(self, k, v):
|
||||
self.data[k] = v.isoformat()
|
||||
|
||||
def get_time(self, k):
|
||||
return None
|
||||
|
||||
|
||||
class _Pub:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *_a, **_k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
ONE = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 5000, "shadow_mode": "off",
|
||||
"maintenance_enabled": False, "stale_input_s": 15}
|
||||
TWO = dict(ONE, setpoint_entity="", soc_entity="", batt_entity="", inverters=[
|
||||
{"name": "inverter-a", "setpoint_entity": "number.a", "soc_entity":
|
||||
"sensor.soc_a", "batt_entity": "sensor.batt_a", "max_w": 2500,
|
||||
"bms_soc_floor": 10},
|
||||
{"name": "inverter-b", "setpoint_entity": "number.b", "soc_entity":
|
||||
"sensor.soc_b", "batt_entity": "sensor.batt_b", "max_w": 2500,
|
||||
"bms_soc_floor": 10}])
|
||||
|
||||
|
||||
def make(opts, hass=None):
|
||||
c = Controller(dict(opts), hass or _Hass(), _Store(), _Pub(),
|
||||
stop=asyncio.Event())
|
||||
c.auto = True
|
||||
for inv in c.inverters:
|
||||
inv.dev_min, inv.dev_max = -5000.0, 5000.0
|
||||
return c
|
||||
|
||||
|
||||
def waiting_on():
|
||||
_hass.OUTAGE.down_on = {"api"}
|
||||
_hass.OUTAGE.since = _hass.OUTAGE._told = _hass.time.monotonic()
|
||||
|
||||
|
||||
def waiting_off():
|
||||
_hass.OUTAGE.down_on = set()
|
||||
|
||||
|
||||
BANNER = "Not ready — Waiting for Home Assistant to finish starting"
|
||||
for label, opts in (("N=1", ONE), ("N=2", TWO)):
|
||||
c = make(opts)
|
||||
waiting_off()
|
||||
plain = c.checks()
|
||||
pay_off = c.status_payload()
|
||||
waiting_on()
|
||||
rows = c.checks()
|
||||
pay = c.status_payload()
|
||||
pay_nl = c.status_payload(lang="nl")
|
||||
waiting_off()
|
||||
check(f"{label}: no waiting row while Home Assistant answers",
|
||||
not [r for r in plain if r.get("id") == "home_assistant"]
|
||||
and pay_off["state"]["kind"] != "waiting")
|
||||
check(f"{label}: while it does not, the waiting row is first and red",
|
||||
rows[0] == {"ok": False, "warn": False, "id": "home_assistant",
|
||||
"banner": messages.banner_ha_waiting(),
|
||||
"text": messages.row_ha_waiting()}
|
||||
and rows[1:] == plain)
|
||||
check(f"{label}: ...and it is the banner ({pay['banner']!r})",
|
||||
pay["banner"] == BANNER and pay["level"] == "bad")
|
||||
check(f"{label}: Home says waiting, not 'Needs you now' "
|
||||
f"({pay['state']['pill']!r}, {pay['state']['sub']!r})",
|
||||
pay["state"]["kind"] == "waiting"
|
||||
and pay["state"]["pill"] == "Waiting for Home Assistant"
|
||||
and pay["state"]["sub"] == "Control resumes by itself when Home "
|
||||
"Assistant answers.")
|
||||
check(f"{label}: ...and in Dutch ({pay_nl['state']['pill']!r})",
|
||||
pay_nl["state"]["pill"] == "Wacht op Home Assistant"
|
||||
and pay_nl["state"]["sub"] == "De regeling gaat vanzelf verder "
|
||||
"zodra Home Assistant antwoordt.")
|
||||
check(f"{label}: Needs attention lists it first, with its own title",
|
||||
pay["attention"][0]["id"] == "home_assistant"
|
||||
and pay["attention"][0]["title"] == "Home Assistant is not answering"
|
||||
and pay_nl["attention"][0]["title"] == "Home Assistant antwoordt "
|
||||
"niet")
|
||||
|
||||
# A safety stop outranks the wait: it still needs a person.
|
||||
c = make(TWO)
|
||||
c.inverters[1].sign_wd.tripped = True
|
||||
waiting_on()
|
||||
pay = c.status_payload()
|
||||
waiting_off()
|
||||
check(f"a safety stop keeps its banner and 'Needs you now' over the wait "
|
||||
f"({pay['banner']!r}, {pay['state']['kind']!r})",
|
||||
pay["banner"] == messages.banner_direction(True)
|
||||
and pay["state"]["kind"] == "alarm")
|
||||
# A stalled control loop does not resume by itself, so it stays the headline.
|
||||
c = make(ONE)
|
||||
c.loop_pass_mono = 0.0
|
||||
waiting_on()
|
||||
rows, pay = c.checks(), c.status_payload()
|
||||
waiting_off()
|
||||
check(f"a stalled control loop stays first and keeps 'Needs you now' "
|
||||
f"({pay['banner']!r})",
|
||||
[r["id"] for r in rows[:2]] == ["controller", "home_assistant"]
|
||||
and pay["state"]["kind"] == "alarm")
|
||||
c = make(dict(ONE, shadow_mode="on"))
|
||||
waiting_on()
|
||||
pay = c.status_payload()
|
||||
waiting_off()
|
||||
check("shadow mode keeps its own state over the wait",
|
||||
pay["state"]["kind"] == "shadow")
|
||||
|
||||
|
||||
# The page script, read as text (the image has no JS engine): an amber dot,
|
||||
# and the batteries tab carries the banner like the other held states.
|
||||
JS = open(os.path.join(os.path.dirname(os.path.abspath(__file__)), "app",
|
||||
"static", "app.js"), encoding="utf-8").read()
|
||||
check("the page script gives 'waiting' an amber dot",
|
||||
re.search(r'alarm: " bad", waiting: " warn" \}\[st\.kind\]', JS)
|
||||
is not None)
|
||||
check("...and shows it as the batteries-tab banner",
|
||||
'["shadow", "stopped", "alarm", "waiting"].includes(S.state.kind)'
|
||||
in JS)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("3. control is unchanged by the waiting flag")
|
||||
|
||||
|
||||
def run(opts, flag):
|
||||
async def go():
|
||||
h = _Hass()
|
||||
c = make(opts, h)
|
||||
(waiting_on if flag else waiting_off)()
|
||||
targets = []
|
||||
for _ in range(4):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
await c.send_heartbeats(asyncio.get_running_loop().time(), 10.0)
|
||||
targets.append(c.target)
|
||||
waiting_off()
|
||||
return targets, h.writes
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
for label, opts in (("N=1", ONE), ("N=2", TWO)):
|
||||
off, on = run(opts, False), run(opts, True)
|
||||
check(f"{label}: same targets and writes with the flag on or off "
|
||||
f"({on[0]}, {len(on[1])} writes)", off == on)
|
||||
check(f"{label}: ...and every write while Home Assistant does not answer "
|
||||
f"asks 0 W", on[1] and all(v == 0.0 for _e, v in on[1]))
|
||||
|
||||
|
||||
# With 502 readings every write is 0 W whatever the flag says, so the check
|
||||
# above cannot see a flag that forces 0 W. Live readings can: the flag alone
|
||||
# must not change a non-zero write.
|
||||
class _LiveHass(_Hass):
|
||||
async def number(self, e, invert=False):
|
||||
v = {"sensor.grid": 900.0}.get(e, 50.0 if "soc" in e else 0.0)
|
||||
return -v if invert else v
|
||||
|
||||
async def set_number(self, e, v):
|
||||
self.writes.append((e, float(v)))
|
||||
return True
|
||||
|
||||
|
||||
def run_live(opts, flag):
|
||||
async def go():
|
||||
h = _LiveHass()
|
||||
c = make(opts, h)
|
||||
(waiting_on if flag else waiting_off)()
|
||||
for _ in range(4):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
await c.send_heartbeats(asyncio.get_running_loop().time(), 10.0)
|
||||
waiting_off()
|
||||
return h.writes
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
for label, opts in (("N=1", ONE), ("N=2", TWO)):
|
||||
off, on = run_live(opts, False), run_live(opts, True)
|
||||
check(f"{label}: with live readings the flag changes no write "
|
||||
f"({on[-2:]})", off == on and any(v != 0.0 for _e, v in on))
|
||||
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
raise SystemExit(1)
|
||||
print("all passed")
|
||||
@@ -767,6 +767,79 @@ ok_i4, out_i4 = validate(dict(defaults, **{_mk: 24}))
|
||||
show("the range is unchanged: 24 is refused (`at most 23`)",
|
||||
(not ok_i4) and "at most 23" in str(out_i4), out_i4)
|
||||
|
||||
print("\n== J. OPT-17: several solar forecast entities per day ==")
|
||||
# The same question as §G, for `pv_forecast_entity` /
|
||||
# `pv_forecast_tomorrow_entity` (`str?` since 0.15.0). Each refusal is
|
||||
# varied from the accepted baseline and asserted on the key's name.
|
||||
# DECISIONS/OPT-17-several-forecast-entities.md.
|
||||
FC_STORED = {"pv_forecast_entity": "sensor.energy_production_today_remaining",
|
||||
"pv_forecast_tomorrow_entity": "sensor.energy_production_tomorrow"}
|
||||
_fc_old = {k: v for k, v in defaults.items()
|
||||
if k not in ("pv_forecast_entities", "pv_forecast_tomorrow_entities")}
|
||||
_fc_base = MERGER.merge(copy.deepcopy(defaults),
|
||||
dict(_fc_old, **FC_STORED))
|
||||
ok_j, out_j = validate(_fc_base)
|
||||
show("a 0.17.0 blob (single forecast keys set, no list keys) validates "
|
||||
"unchanged, and both new keys default to []",
|
||||
ok_j and out_j.get("pv_forecast_entity") == FC_STORED["pv_forecast_entity"]
|
||||
and out_j.get("pv_forecast_entities") == []
|
||||
and out_j.get("pv_forecast_tomorrow_entities") == [],
|
||||
"" if ok_j else out_j)
|
||||
for _k in ("pv_forecast_entity", "pv_forecast_tomorrow_entity"):
|
||||
_s1 = dict(schema, **{_k: ["str"]})
|
||||
ok_j1, out_j1 = validate_with(_s1, _fc_base)
|
||||
show(f"`{_k}` declared as a LIST refuses the string an install stores",
|
||||
(not ok_j1) and f"Invalid list for option '{_k}'" in str(out_j1),
|
||||
out_j1)
|
||||
_m1 = MERGER.merge(copy.deepcopy(dict(defaults, **{_k: []})),
|
||||
copy.deepcopy(FC_STORED))
|
||||
ok_j2, out_j2 = validate_with(_s1, _m1)
|
||||
show("...and a `[]` default does not rescue it (list merge is override)",
|
||||
_m1[_k] == FC_STORED[_k] and not ok_j2, out_j2)
|
||||
_sm = dict(schema, **{_k: "match(.*)?"})
|
||||
_ok_s, _ = validate_with(_sm, _fc_base)
|
||||
_ok_l, _ = validate_with(_sm, dict(_fc_base, **{_k: ["sensor.a",
|
||||
"sensor.b"]}))
|
||||
_ok_n, _ = validate_with(_sm, dict(_fc_base, **{_k: 417}))
|
||||
_ui_m = _ui_of(_sm, _k)
|
||||
show(f"...`match(.*)?` on `{_k}` takes a string AND a list, but also the "
|
||||
"integer 417, and renders as a plain text box (no second row)",
|
||||
_ok_s and _ok_l and _ok_n and _ui_m
|
||||
and _ui_m[0].get("multiple") is not True,
|
||||
f"string={_ok_s} list={_ok_l} integer-417={_ok_n} "
|
||||
f"ui={json.dumps(_ui_m)}")
|
||||
_two = ["sensor.fc_east", "sensor.fc_west"]
|
||||
ok_j3, out_j3 = validate(MERGER.merge(copy.deepcopy(defaults), dict(
|
||||
_fc_old, pv_forecast_entities=_two,
|
||||
pv_forecast_tomorrow_entities=_two)))
|
||||
show("⭐ SHIPPED: two-entity lists for today and tomorrow validate",
|
||||
ok_j3 and out_j3.get("pv_forecast_entities") == _two
|
||||
and out_j3.get("pv_forecast_tomorrow_entities") == _two,
|
||||
"" if ok_j3 else out_j3)
|
||||
for _k in ("pv_forecast_entities", "pv_forecast_tomorrow_entities"):
|
||||
ok_j4, out_j4 = validate({k: v for k, v in defaults.items() if k != _k})
|
||||
show(f"...and the `options:` block with ONLY `{_k}` removed is refused "
|
||||
"by name, so its `[]` default is load-bearing",
|
||||
(not ok_j4) and f"Missing option '{_k}' in root" in str(out_j4),
|
||||
out_j4)
|
||||
_ui_j = _ui_of(schema, _k)
|
||||
show(f"...and `{_k}` renders as a repeatable string field",
|
||||
len(_ui_j) == 1 and _ui_j[0].get("multiple") is True
|
||||
and _ui_j[0].get("type") == "string", json.dumps(_ui_j))
|
||||
_flat_j = {k: v for k, v in schema.items()
|
||||
if k not in ("pv_forecast_entities", "pv_forecast_tomorrow_entities")}
|
||||
try:
|
||||
_rj = vol.Schema(vol.All(dict, AppOptions(
|
||||
None, _flat_j, cfg["name"], "local_goodwe_controller")))(
|
||||
MERGER.merge(copy.deepcopy(defaults), dict(
|
||||
FC_STORED, pv_forecast_entities=_two)))
|
||||
show("a DOWNGRADE to 0.17.0's schema drops the list keys and keeps the "
|
||||
"single ones",
|
||||
"pv_forecast_entities" not in _rj
|
||||
and _rj.get("pv_forecast_entity") == FC_STORED["pv_forecast_entity"])
|
||||
except vol.Invalid as e:
|
||||
show("a DOWNGRADE to 0.17.0's schema drops the list keys", False, str(e))
|
||||
|
||||
# ⚠️ THE EXIT CODE IS PART OF THE INSTRUMENT. Without it the probe prints FAIL
|
||||
# and still succeeds, and a transcript is only evidence if a wrong answer is
|
||||
# distinguishable from a right one by something other than reading it.
|
||||
|
||||
@@ -91,6 +91,12 @@ configuration:
|
||||
pv_forecast_tomorrow_entity:
|
||||
name: "Hardware · Solar forecast, tomorrow (kWh)"
|
||||
description: "Optional. The same forecast for tomorrow. It helps plan a cheap hour before midnight."
|
||||
pv_forecast_entities:
|
||||
name: "Hardware · Several solar forecasts, today (kWh)"
|
||||
description: "Optional. One row per forecast sensor, such as one per inverter, used instead of the single one above. They are added up."
|
||||
pv_forecast_tomorrow_entities:
|
||||
name: "Hardware · Several solar forecasts, tomorrow (kWh)"
|
||||
description: "Optional. The same list for tomorrow. If one sensor has no reading, that day's forecast is not used."
|
||||
solar_trust_pct:
|
||||
name: "Hardware · Trust in the forecast (%)"
|
||||
description: "Forecasts are often too sunny. At 70 % the add-on plans with 7 of every 10 kWh forecast."
|
||||
|
||||
@@ -72,6 +72,12 @@ configuration:
|
||||
pv_forecast_tomorrow_entity:
|
||||
name: "Hardware · Zonneprognose, morgen (kWh)"
|
||||
description: "Optioneel. Dezelfde prognose voor morgen. Ze helpt een goedkoop uur voor middernacht te plannen."
|
||||
pv_forecast_entities:
|
||||
name: "Hardware · Meerdere zonneprognoses, vandaag (kWh)"
|
||||
description: "Optioneel. Eén rij per prognosesensor, bijvoorbeeld per omvormer, in plaats van de losse sensor hierboven. Ze worden opgeteld."
|
||||
pv_forecast_tomorrow_entities:
|
||||
name: "Hardware · Meerdere zonneprognoses, morgen (kWh)"
|
||||
description: "Optioneel. Dezelfde lijst voor morgen. Heeft één sensor geen meting, dan wordt de prognose voor die dag niet gebruikt."
|
||||
solar_trust_pct:
|
||||
name: "Hardware · Vertrouwen in de prognose (%)"
|
||||
description: "Prognoses zijn vaak te zonnig. Bij 70 % plant de add-on met 7 van elke 10 kWh uit de prognose."
|
||||
|
||||
Reference in New Issue