Compare commits

...
7 Commits
Author SHA1 Message Date
ems-agentandClaude Opus 5.5 550d2d3934 Release 0.25.0: version bump and CHANGELOG
infra-pin / fresh (pull_request) Waiting to run
checks / unit (pull_request) In progress
Pinned to EV-51's merge c79eb37 on release/1.0 (TOOL-51, go #62).
Only goodwe_controller/config.yaml (version) and CHANGELOG.md change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-25 12:57:38 +01:00
ems-agent c79eb37392 Merge pull request 'EV-51: Solar decides every meter-age rule on the writer step's own age; DEBUG line per step' (#275) from EV-51 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-11-25 01:19:19 +01:00
ems-agentandClaude 45df1ac549 EV-51 review: T45 sweeps N8 on own age for retries and phase-change closing currents; docs name the decision words and C23
checks / unit (pull_request) Successful in 54m7s
infra-pin / fresh (pull_request) Successful in 2s
T45: race order, 5 s and 10 s cycles, silence onset swept 1 s at a time,
(a) a raise the charger ignores (re-sends) and (b) a 1 -> 3 phase change
(closing current): no non-zero current write at own age > 30 s. Red on
5bff894 and on the reviewer's R4 (nz_block from the snapshot, C23 on own
age), green on head. T26 also checks the DECISIONS entry names every
decision word and the C23 value rule.

DECISIONS and the car_sun_own / _car_step_debug docstrings: snapshot values
are used only while the step's own age says fresh (C23); the decision words
are listed. No code change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-25 00:04:10 +01:00
ems-agentandClaude 6412d00783 EV-51 round 2: T44 checks the start after the meter returns; T24 SoC 100 no longer carries N5
checks / unit (pull_request) Successful in 37m42s
infra-pin / fresh (pull_request) Successful in 2s
T44 (C23) now also asserts that a start and a non-zero write come, either
before the silence passes 30 s (from fresh data) or after the meter is back
at a step with own age <= 30, between the first fresh step + ev_start_min
and that + 2 cycles, and that the car is still charging at the end. A fix
that blocks every start after a silence fails it.

T24: the SoC 100 run (no battery write in the silence) is checked for T24
only; N5 rides on the SoC 50 runs, which must have writes in the silence.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-24 22:05:33 +01:00
ems-agentandClaude a33eb8ef1c EV-51 round 1: C23 (no spare/target from data the own age calls old), N5 label, T44
checks / unit (pull_request) Successful in 38m23s
infra-pin / fresh (pull_request) Successful in 2s
car_sun_own now sets spare_w / target_w to None while the step's own meter age
says silent, so no plan start or raise comes from a snapshot value over
meter_max_age_s old; the start comes from a fresh reading after the meter
returns, with its dwell. T44 sweeps a start due just after the silence (red on
68856bc, green now). T24 is labelled N5 and also runs at SoC 50 so the
batteries' setpoints in the silence are compared.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-24 19:52:36 +01:00
ems-agentandClaude 68856bc3a0 EV-51: Solar decides every meter-age rule on the writer step's own age; DEBUG line per step
checks / unit (pull_request) Successful in 41m26s
infra-pin / fresh (pull_request) Successful in 2s
The writer step took the meter age from the snapshot of the previous cycle
(silent / unknown_s / hold), so in production order the silent-meter pause
came one cycle late (C21) and a start or raise could still be written at an own
age of 31-39 s (C22, N8). The step now judges its own age: the pause timing and
held_pause, the non-zero write block (nz_block), and the late-readings hold with
its stale rule. Meter values stay from the snapshot; car.held / car.reading and
the arrival sources' spare-unknown check are unchanged.

Also: one DEBUG line per Solar writer step (time, meter age, decision, write);
tools/ev20_sun.drive takes cyc / phase / jitter / cset (default unchanged);
test_ev51.py (T1-T43, N1-N12); DECISIONS states the rule once.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-24 17:26:03 +01:00
ems-agent 5bff894cca Merge pull request 'EV-20 rig round 2: no pause on a short charger read gap; ha_signed pause timed from the meter age' (#274) from EV-20-r2 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-11-24 10:10:11 +01:00
8 changed files with 1285 additions and 17 deletions
+128 -5
View File
@@ -1,11 +1,134 @@
# Changelog
### Not in a release yet
## 0.25.0
- **The car can now charge from spare sun (Solar mode).** Choose *Solar* on the Car card or in Home Assistant: the car gets only the sun the house does not use, after the batteries (or before them, your choice), and pauses when there is too little. Every way out of Solar, a stop and a restart set the charger to 0 A. Three new options, all with defaults: `ev_margin_w`, `ev_start_min`, `ev_pause_min`. See "Car charger" in DOCS ([[EV-20]]).
- When the car charger does not take a current setting but is plainly working, you now see one amber row ("did not take the setting"), not a second "reading may be stuck" ([[EV-13]]).
- The add-on no longer changes the car's phases while the car still draws: it waits until the charger reads under 100 W, and if the car is still drawing after 20 s it gives the current back and tries again after 10 minutes ([[EV-28]]).
- When the add-on changes the car's phases while the batteries are at the peak reserve, there is no longer a false "Battery stopped limiting the peak" for a moment ([[EV-15]]).
**A minor bump: the car can now charge from spare sun (Solar mode), and the Car card raises fewer false alarms. Three new options were added, all with defaults, and none needs setting.**
Three options were added (`ev_margin_w`, `ev_start_min` and `ev_pause_min`), none was removed or renamed, and no default changed (95 options, 92 before). **Existing installs need no option change:** the new options have defaults, and `ev_charger` is still off, so an install that does not use the car charger runs as 0.24.0 did. It is a minor bump because it adds a feature and new options. Every saved setting still starts.
**The car can charge from spare sun (Solar mode).** Choose *Solar* on the Car card or in Home Assistant. The car gets only the sun the house does not use, after the batteries or before them (your choice), and pauses when there is too little. When the sun cannot be measured, for example when the meter goes silent, the current stands for 5 minutes and then goes to 0 A. Every way out of Solar, a stop and a restart set the charger to 0 A. See "Car charger" in DOCS ([[EV-20]], [[EV-51]]).
**Car charger fixes.** The add-on no longer changes the car's phases while the car still draws. Fewer false "Battery stopped limiting the peak" alarms while the car charges. A current the charger does not take shows one amber row, not two. The Car card's *Why* line says what the charger does and no longer switches between two wordings ([[EV-28]], [[EV-15]], [[EV-18]], [[EV-19]], [[EV-13]], [[EV-14]], [[EV-16]]).
**No change in behaviour:** the build checks now test against a newer copy of the shared test tools.
Contents of this release, in merge order since 0.24.0 (`f66048b`):
| | |
|---|---|
| `9fdce02` | When the add-on changes the car's phases while the batteries are at the peak reserve, there is no longer a false "Battery stopped limiting the peak" for a moment ([[EV-15]], #262) |
| `43b0db7` | While the car explains why the house is over the peak limit, the alarm no longer fires at the start of a 15-minute period and stays red for the whole period ([[EV-18]], #264) |
| `8150608` | No alarm for a moment when the batteries first reach the peak reserve early in a Manual car session ([[EV-19]], #265) |
| `00b116e` | With *Batteries help with the peak* on, the Car card's *Why* line no longer switches between two wordings while the car is over the peak limit ([[EV-16]], #266) |
| `4eba2d9` | The build checks test against a newer copy of the shared test tools. There is no change in behaviour ([[CI-20]], #267) |
| `76f4de2` | The add-on no longer changes the car's phases while the car still draws. It waits until the charger reads under 100 W, and if the car still draws after 20 s it gives the current back and tries again after 10 minutes ([[EV-28]], #268) |
| `c8f5292` | When the charger does not take a current setting but is plainly working, you see one amber row ("did not take the setting"), not a second "reading may be stuck" ([[EV-13]], #269) |
| `885528a` | In shadow mode, and after a phase change was given up, the Car card's *Why* line says what the charger does, not what you set ([[EV-14]], #270) |
| `cc8c0dc` | The car can charge from spare sun (Solar mode), with three new options: `ev_margin_w`, `ev_start_min` and `ev_pause_min` ([[EV-20]], #271) |
| `09b6af9` | Solar mode: no false "charger reading may be stuck" after the add-on's own write, no back and forth between two currents, and the waits count from when the sun drops ([[EV-20]], #272) |
| `2768755` | The build checks test against a newer copy of the shared test tools. There is no change in behaviour (#273) |
| `5bff894` | Solar mode: one failed charger reading no longer pauses the car in full sun ([[EV-20]], #274) |
| `c79eb37` | Solar mode: when the meter goes silent, the car goes to 0 A at the first check once the meter reading is 330 s old ([[EV-51]], #275) |
### Known issues
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
- A battery whose reading at rest is beyond about ±175 W is still not caught when it refuses ([[SAFETY-97]]).
- The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s. This is about the guard's discharge only; a grid charge is cut back since 0.19.2 ([[SAFETY-99]]).
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
- Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]).
- Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]).
- Two inverters: when a battery drops out during a solar surplus, the others can swing by up to 1.5 kW in a simulation ([[SAFETY-105]]).
- Two inverters: after a drain ends, a change in house use can go unanswered for about 9 s, because some readings are old ([[SAFETY-106]]).
- Two inverters: when one battery's level is missing, both batteries are held at 0 W, and for about 15 s the last command stays on ([[SAFETY-108]]).
- Two inverters: if one battery's level stays missing for 12 h, the other battery's cycle can be marked failed, with a 7-day wait and a notice, though it is healthy. This comes from reading the code; it has not been seen on a site ([[MAINT-17]]).
- When the 15-minute demand forecast sensor counts the battery's own charge, the maintenance charge runs at about half the power the peak limit leaves, so it takes about twice as long (seen on a site: about 1.2 kW instead of 2.5 kW; the peak limit was kept). At the start of a month, before a peak above the limit, that is about 2 kWh a night in a rig test: the cycle can reach its 36 h limit after about 4 nights and fail, and since 0.22.0 the other battery gets no grid charge on those nights ([[SAFETY-111]]).
- One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]).
- After a Home Assistant restart, control still waits until Home Assistant has finished starting, which can take several minutes, though the readings are already there ([[SAFETY-115]]).
- While Home Assistant is not answering, the page can list inverters as refusing commands and sensors as missing, and send you to Developer Tools, though they are fine ([[UX-37]]).
- If Home Assistant hangs or stops, the page keeps saying "Waiting for Home Assistant" and never turns into an alarm ([[SAFETY-113]]).
- Right after Home Assistant has started, the page can say for about 4 s that an inverter cannot be controlled, and the first command can come late ([[SAFETY-114]]).
- After a Home Assistant restart, the controller status sensor can still say "running" while the add-on cannot control. It was seen once, and the cause is not known ([[SAFETY-116]]).
- Battery modes on: after a planned top-up from the grid, the Batteries screen can say "Enough sun is forecast" ([[UX-32]]).
- Battery modes on: the forecast line "we count on" can show more sun than the plan counts, because the plan takes house use off first ([[UX-33]]).
- Battery modes on: before a planned top-up, the Today list shows a smaller "gives" amount than the plan will use; it grows as the charge happens ([[UX-34]]).
- Two inverters, battery modes on: while the other battery is in its maintenance charge, a battery's card can say it charges from the grid while it stays at 0 W ([[OPT-18]]).
- Two inverters, battery modes on: while a battery refuses to charge in a cheap run, the action log on the page gets about 8 lines an hour for its retries, and the page hint says "waiting for a better price" ([[UX-38]]).
- A battery in a safety stop, or one the add-on cannot reach, can still be started for a cycle, and its drain then waits about 12 h and ends in a failed-cycle notice. This comes from reading the code; it has not been seen on a site ([[MAINT-19]]).
- On the Settings page, the rows of the solar forecast lists are labelled "Phase 1", "Phase 2" instead of "Sensor 1", "Sensor 2" ([[UX-27]]).
- In the solar forecast list, a blank or repeated row makes "source 2 of 2" count differently from the rows on the Settings page ([[UX-28]]).
- The solar forecast message says "has no reading" also when the sensor shows a number that is too old or in the wrong unit ([[UX-29]]).
- If you use only the forecast lists, two Settings notes sit on the single-sensor field, and one of them tells you to set that field ([[UX-30]]).
- After a restart during a price outage, the "No prices" message can say "yet" when prices did come in earlier ([[UX-39]]).
- On the new settings page, you cannot see whether a price service token is set. Check the Configuration tab ([[UX-41]]).
- On the classic settings page, the first click on Save after editing a field can do nothing. Click again ([[UX-42]]).
- A steady overload on a 1 s meter can warn, and send the Home Assistant notification, 2 or 3 times at the start of each 15-minute period instead of once. The peak limit is still kept ([[SAFETY-122]]).
- A fixed tariff is priced once per hour, so a price window that starts or ends at :15, :30 or :45 gets the wrong price for part of that hour. Windows that start and end on the hour are right ([[TARIFF-23]]).
- Step 6 of the setup wizard stays empty because of an error in the page, in English and in Dutch ([[UX-51]]).
- On Dutch pages, refusal texts, the last-event line under the Home buttons, the installer details and the trading status sentences are still English, and a few Dutch texts read badly, such as "1 metingen geweigerd" ([[UX-52]]).
- Some price texts say "hour" where the add-on acts on a 15-minute period, such as "cheapest hour" ([[UX-47]]).
- After the add-on restarts, the Home price chart shows no price for the earlier part of today, and the setup check can say "12 of 24 hours", though the prices are known ([[UX-48]]).
- With battery modes on and only batteries on "Leftover solar", the Home price chart can mark a cheap period where no battery charges ([[UX-49]]).
- On a phone, the bars of the Home price chart are too thin to tap one 15-minute period. The arrow keys work ([[UX-50]]).
- In the last second of a 15-minute period, being a few watts over the aim can make the peak guard ask a battery for full power for one second. When a charge ends on a period edge, the last-second give can fade out over about 10 s, and a rig test exported up to 7.4 kW for about 8 s ([[SAFETY-124]]).
- During the night grid charge, a 15-minute period can end 6 to 14 W over the peak aim, because the battery charges harder than asked. This was seen in simulation; a rig test saw 2 to 8 W ([[OPT-35]]).
- The test rig could not bring back the false peak alarm that [[SAFETY-126]] fixes, so that fix is shown in simulation only. Watch the notifications for a few nights ([[TEST-35]]).
- The night cheap run is sized for the batteries' full charging power, not for what the peak limit leaves. Under a tight limit the run can end before the batteries reach their level, and Home can show a level they do not reach (79.9 % against a shown 95 % in a rig test) ([[OPT-25]]).
- By day, a Leftover solar plan that has only a daily forecast figure counts the sun from now, not from when the figure was read. It counts about 22 % too much for a figure one hour old; the night plan is not affected ([[OPT-30]]).
- The night charge can buy too much in a house that uses more at night than by day, such as one with a heat pump or a car charger that is not set up in the add-on, and on a sunny day, because spare sun in one expensive hour does not count for the later ones ([[OPT-31]]).
- A cheap run that has already started can overlap a new give run after a re-plan, so a battery can charge from the grid at the dearest price for part of an hour. This was seen in a test case, not on a site. Also in 0.19.2 ([[OPT-32]]).
- If the solar forecast sensors stop updating before 17:00, as in winter or further north, there is no forecast from three hours after their last update until 20:00 ([[OPT-33]]).
- With a forecast that gives only a daily total, the sun is spread an hour off on the two clock-change days after the change. The day's total is right ([[OPT-24]]).
- The add-on learns the house's use only once a solar forecast is set, so a site that adds a forecast later waits one more day for its first plan ([[OPT-26]]).
- Home says "No trading on price yet: no prices have arrived" when every battery is on Solar first, though the prices are shown ([[UX-55]]).
- The Home plan header can say "Charges in the cheapest hour, gives power in the dearest" when Home draws no charge, and it says "hour" for 15-minute prices ([[UX-56]]).
- While the peak guard holds back charging, Home hides the rest of the cheap run and gives no reason. The charge starts again when the guard lets go ([[UX-57]]).
- With battery modes on and selling on, Home can draw a "Sells up to" block when the add-on judges the trade not worth it, and then it will not sell ([[UX-58]]).
- Home, the plan and the Forecast tab stop drawing a battery's give at the trading floor, though control goes on giving down to the battery's cut-out ([[UX-59]]).
- During a price outage, the Batteries screen says "Prices differ too little" and Home says "The price gap is too small" ([[UX-60]]).
- With battery modes on and no meter, or a meter that is a Home Assistant entity, a grid charge is not possible and nothing says so ([[UX-61]]).
- On the Batteries screen, a charge the add-on refused in a cheap run reads as "Saves its power for ...", for up to 15 minutes ([[UX-62]]).
- A Leftover solar battery with no capacity set never charges from the grid when a solar forecast is set, and nothing warns about it ([[UX-63]]).
- The "How the modes work" box on the Batteries screen does not describe Cheap hours only ([[UX-64]]).
- With battery modes on, Settings still shows "Trade on the price spread", which the modes ignore. A site with modes on and no price source starts, and the Batteries screen says "No prices, so it follows the house" without pointing to Settings ([[UX-65]]).
- With battery modes off and several equal prices in a row, Home and the Forecast tab draw one price quarter, while the add-on trades every quarter of the run ([[UX-67]]).
- Late in the day, the Forecast tab's "now" line and last bars sit over the axis labels at the right edge ([[UX-68]]).
- The Forecast tab's level curve charges at each battery's full rating. Under a peak limit the levels it draws are too high and a charge block can end early (54.6 % shown against 39.7 % in a rig test) ([[UX-70]]).
- The peak forecast check says maintenance charging is not kept under the peak limit when no peak forecast is set, but since 0.19.2 it is ([[UX-73]]).
- The peak guard row can show the same figure twice, such as "at this rate 3 500 W, over 3 500 W". Also in 0.19.2 ([[UX-74]]).
- If the inverter's setpoint entity appears in Home Assistant after the add-on has started, the page keeps saying "Inverter control: not found in Home Assistant" and the batteries say "An alarm stopped control" until a restart, though control runs ([[UX-75]]).
- In the last minute of a 15-minute period, with Home Assistant readings 30 s late, the period can end about 80 W over the peak aim and over the limit: 3 530 W against a 3 450 W aim and a 3 500 W limit in a rig test with a 2 kW load added 45 s before the end. The peak guard sees the load too late to hold it back ([[SAFETY-133]]).
- With Home Assistant readings 10 s late, the grid charge in a cheap run can swing by several kW. In a test the add-on asked for an 8.7 kW charge (9.6 kW on 0.20.0) ([[SAFETY-132]]).
- A plan rebuilt while the battery levels are missing for a moment can drop a cheap run that has not started yet, so the battery does not charge that day. Seen in a replay of real prices, where it cost about EUR 0.40 of extra grid use; the Leftover solar change in 0.20.1 no longer triggers it in those replays, but the cause stays ([[OPT-37]]).
- On a 5 s meter, Home Assistant readings 10 s late are still not caught, and readings 15 s late only after about 4 minutes. Control now follows the meter more gently, so less goes to the grid: in a simulation with a changing load, 340 Wh became 189 Wh at 10 s late and 363 Wh became 296 Wh at 15 s late. In a rig test, 15 s late exported 13 to 19 % more than before ([[SAFETY-136]], [[SAFETY-134]]).
- With readings 10 to 15 s late, the hold can end in the middle of the delay and the swing can come back. Seen in rig tests with a 2 s and a 5 s meter ([[SAFETY-134]]).
- With readings 10 s late on a 1 s meter, the grid can still move between -422 and +340 W while the batteries are held. With a very long delay (30 to 90 s) the request can swing by about 900 W every few seconds. Seen in review tests ([[SAFETY-130]]).
- A battery that answers very slowly (10 s or more) can be taken for late Home Assistant readings and held, and the page then blames Home Assistant. A GoodWe battery settles in about 6 s and this has not been seen on one ([[SAFETY-131]]).
- The page row for late readings reads awkwardly in English ("Home Assistant readings show requests about N seconds late, so control holds the batteries"), and the Dutch text misses a word ([[UX-78]]).
- When the add-on stops, a write that takes more than 2 s can still land after the 0 W, and the 30 s safety timer on the ESPHome board then sets 0 W. After the Stop button, a cycle that had already decided can send its share (560 to 670 W) just after the 0 W; the next cycle sends 0 W again ([[SAFETY-138]]).
- In the last hour of a cheap run, Home can draw a battery's grid charge up to an hour past the time control stops charging it. It only draws too much, never too little ([[UX-79]]).
- A tomorrow solar forecast sensor that reports just after midnight with yesterday's value can be used as the new day's forecast for up to 12 hours. This has not been seen on a site ([[OPT-39]]).
- During a cheap-hours charge, at some 15-minute boundaries the add-on sends 0 W for one tick ("no trade (headroom)") and then goes on. Seen in a rig test, in 5 of 8 cases; once, with a frozen battery reading, it left a battery at 0 W until 23:45 ([[OPT-40]]).
- While one battery's monthly cycle charges, the other battery's card on Home says "Saves its power for higher prices", and the plan still shows its grid charge in the cheap hours, though it will not charge ([[UX-80]]).
- After a failed monthly cycle, the plan line shows the day the wait ends, such as 18 November, not when the cycle tries again, such as 19 November at 19:00 ([[MAINT-26]]).
- At the start of a cheap window the peak guard can step once although the period is under the aim, and the step can land on a battery in its monthly charge. In a rig test it gave 1.7 to 2.3 kW for 6 s ([[SAFETY-140]]).
- A grid charge at full power in the last seconds of a 15-minute period can run into the next period, where the peak guard cuts it back ([[SAFETY-139]]).
- In a long real peak, the peak guard can end a 15-minute period up to 10 W over its aim, as 0.22.0 does (up to 31 W there). In a rig test the month's highest peak did not rise ([[SAFETY-141]]).
- The peak reserve notification can be created again and again, 24 to 47 times in 2 hours in a rig test, while the guard holds a battery at its reserve. 0.22.0 does the same ([[MAINT-29]]).
- When you switch the car charger off, its three sensors stay in Home Assistant with their last values. From reading the code, the PV power sensor does the same when it is switched off ([[TEL-19]]).
- In Settings, the choice for no car charger says "None", while its help says "Off" ([[UX-81]]).
- DOCS names the car's energy sensor `goodwe_car_today_kwh`, but Home Assistant creates it as `sensor.goodwe_car_energy_today` ([[TEL-20]]).
- While the car charges in Manual mode, a false "Battery stopped limiting the peak" can still show in the first minutes of a 15-minute period, though the period is heading under the limit. Seen in rig tests, also on builds before this one ([[EV-19]]).
- The fixes for [[EV-14]], [[EV-18]] and [[EV-19]] are shown in tests only: the test rig could not run them or could not show a difference. Watch the Car card and the notifications for a few nights.
### If you are crossing from a version older than 0.10.0
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
bare options (`jq '.data.options'`) first.
## 0.24.0
@@ -161,9 +161,26 @@ one small set of facts and derives every path from them:
This also ends the false PEAK_GUARD_FLOOR_LIMITED after one gap (EV-18
T10(b) changed accordingly).
- **Silent meter on `ha_signed`:** Solar's unknown-sun pause is timed from the
meter's age: unknown since the age passed `meter_max_age_s`, so 0 A when the
age reaches `meter_max_age_s` + `ev_pause_min` (330 s), checked every
control cycle (bound 330 s + one cycle). Arrival sources are unchanged.
meter's age: unknown since the age passed `meter_max_age_s`, so 0 A on the
first car step whose own meter age (now minus the last reading, at that
step) is >= `meter_max_age_s` + `ev_pause_min` (330 s), held steps included.
Arrival sources are unchanged.
- **EV-51: decided at the step's own meter age.** Every decision that rests on
the meter's AGE is taken at the writer step's own age, not at the age the
cycle saw one step earlier: the pause above, the write block while the meter
is silent (no non-zero current, C17), the held-read pause (C18) and the
late-readings hold with its stale rule (a spare read while the hold was on
is not used once the step's own late time reaches `stale_input_s`). The
meter's VALUES (spare, target) stay the cycle's, one cycle of sensor latency
being normal, but only while the step's own age says the meter is fresh:
once it is past `meter_max_age_s` the spare is unknown, so nothing starts or
rises from it (C23). `car.held` and `car.reading` are unchanged. Arrival
sources keep the cycle's age for their "spare unknown" check. At log level
debug each Solar step logs one line: time, the meter age at the step, the
decision and the write. The decision is one word: `steady`, `start`,
`raise`, `lower`, `pause`, `hold` (the late-readings hold), `wait-unknown`
(the spare is unknown and the pause timer counts) or `wait-held` (a held
charger read).
- **No non-zero write while the meter is silent (SPIKE-06 C17, N8 strict):**
while the meter's age is past `meter_max_age_s`, Solar sends no non-zero
current: no retry, no raise, no phase change begun, and a phase change
+14 -4
View File
@@ -498,8 +498,13 @@ class SunInputs:
def __init__(self, target_w=None, hold=False, auto=True, start_s=120.0,
pause_s=300.0, spare_w=None, room_w=0.0, margin_w=100.0,
first=DEFAULT_FIRST, unknown_s=0.0, silent=False):
first=DEFAULT_FIRST, unknown_s=0.0, silent=False,
meter_back=False, age_s=None):
self.target_w, self.hold, self.auto = target_w, hold, auto
# EV-51: the meter's own age at the writer step (None: no reading), and
# `meter_back`: the cycle's snapshot said "meter too old" but the step's
# own age says a new reading came, so no unknown timer is carried over.
self.meter_back, self.age_s = meter_back, age_s
# EV-20 rig round 2: how long the sun has already been unknown when
# the cause is the meter's own age (`ha_signed`): the pause is timed
# from that age, not from the cycle that noticed it.
@@ -570,11 +575,15 @@ class SolarPlan:
self.switch, self._before = False, None
def step(self, now, *, target_w, n_now, auto, clamp, start_s, pause_s,
hold=False, gap_ok=True, unknown_s=0.0):
hold=False, gap_ok=True, unknown_s=0.0, meter_back=False):
"""`n_now`: the phases the car draws on now (1 for a one-phase car);
`auto`: Solar may choose the phases; `gap_ok`: a phase change is
allowed now (EV-04's one per `PHASE_GAP_S`); `hold`: readings late
under the stale bound, everything stands."""
under the stale bound, everything stands. `meter_back` (EV-51): the
meter's own age is fresh again at this step: the unknown timer that
counted its silence starts over."""
if meter_back:
self.unknown_since = None
if hold:
# Readings late under the stale bound: nothing changes, but a
# hold or an unknown spare that has run its time still pauses
@@ -937,7 +946,8 @@ class SolarWriter(ManualWriter):
now, target_w=sun.target_w, hold=sun.hold, n_now=n_now,
auto=sun.auto and not self.single and not self.phases_gave_up,
clamp=clamp, start_s=sun.start_s, pause_s=sun.pause_s,
gap_ok=gap_ok, unknown_s=getattr(sun, "unknown_s", 0.0))
gap_ok=gap_ok, unknown_s=getattr(sun, "unknown_s", 0.0),
meter_back=getattr(sun, "meter_back", False))
@staticmethod
def _drawing(r) -> bool:
+72 -2
View File
@@ -10,6 +10,7 @@ the guard treats a Solar car exactly as a Manual car).
"""
import asyncio
import copy
import dataclasses
import logging
from datetime import timezone
@@ -83,6 +84,7 @@ class CarMixin:
self.car_first = first if first in carmode.FIRSTS \
else carmode.DEFAULT_FIRST
self._car_late_s = None # EV-20: the cycle's late verdict
self._car_late_mono = None # ... and the time it was read (EV-51)
self._car_sun_now = None # ... and Solar's inputs of that cycle
sun = data.get(CAR_SUN_KEY)
self.car_sun = {"day": None, "kwh": 0.0}
@@ -372,8 +374,76 @@ class CarMixin:
now = self.car_now()
sun = None
if self.car_mode == carmode.SOLAR:
sun = getattr(self, "_car_sun_now", None) \
or self.car_sun_inputs(now)
sun = self.car_sun_own(getattr(self, "_car_sun_now", None)
or self.car_sun_inputs(now), now)
w0 = self.car_solar
a0, n_log = w0.plan.a, len(w0.log)
await self._car_step_run(held, now, sun)
if sun is not None and _LOG.isEnabledFor(logging.DEBUG):
self._car_step_debug(held, now, sun, a0, n_log)
def _car_step_debug(self, held, now, sun, a0, n_log) -> None:
"""EV-51: one DEBUG line per Solar writer step: the time, the meter's
age at the step, what was decided and what was written. The decision
is one word: steady, start, raise, lower, pause, hold (the
late-readings hold), wait-unknown (the spare is unknown and the pause
timer counts) or wait-held (a held charger read). Nothing at info and
above; no secrets in it."""
w = self.car_solar
a1 = w.plan.a
if a0 > 0.0 and a1 <= 0.0:
what = "pause"
elif held:
what = "wait-held"
elif sun.hold:
what = "hold"
elif a0 <= 0.0 and a1 > 0.0:
what = "start"
elif a1 > a0 + carmode.TOL_A:
what = "raise"
elif a1 < a0 - carmode.TOL_A:
what = "lower"
elif sun.target_w is None:
what = "wait-unknown"
else:
what = "steady"
sent = []
for kind, v, _t, ok in w.log[n_log:]:
if kind == "current":
sent.append(f"sent {v:g} A" + (" confirmed" if ok else ""))
else:
sent.append(f"phases {v}" + (" confirmed" if ok else ""))
age = sun.age_s
_LOG.debug("Solar step: t=%.1f age=%s decision=%s write=%s", now,
"none" if age is None else f"{age:.1f}", what,
"; ".join(sent) or "none")
def car_sun_own(self, snap, now):
"""EV-51 (PM): every decision on the meter's AGE is taken at the writer
step's own age (now minus the meter's last reading), not the age the
cycle saw one step earlier: the write block while the meter is silent
(N8), the unknown/pause timing (held reads too) and the late-readings
hold with its stale rule. The meter's VALUES (spare, target) stay the
cycle's only while the step's own age says the meter is fresh; once it
is past `meter_max_age_s` they are unknown (C23). Arrival sources'
`car_spare_w` keeps the cycle's age."""
own = copy.copy(snap)
own.silent = self._car_meter_silent()
own.unknown_s = self._car_meter_over_s()
own.age_s = self.p1.age_s() if self.p1_enabled else None
own.meter_back = snap.unknown_s > 0.0 and own.unknown_s <= 0.0
stale = float(self.o.get("stale_input_s", 15))
late = self._car_late_s # the verdict stands: it has aged since
if late is not None and self._car_late_mono is not None:
late += max(0.0, now - self._car_late_mono)
own.hold = late is not None and late < stale
if own.silent or (late is not None and late >= stale):
# The stale rule on the step's own age / own late (C23): a spare
# read from data the own age calls old starts or raises nothing.
own.spare_w = own.target_w = None
return own
async def _car_step_run(self, held, now, sun) -> None:
if held:
# EV-20 rig round 2 (PM): the charger missed a read for less than
# `stale_input_s`; the last trusted figure stands and nothing is
+1
View File
@@ -254,6 +254,7 @@ class CycleMixin:
stale_after = float(self.o.get("stale_input_s", 15))
late_s = self._readings_late(site_standing) # SAFETY-128
self._car_late_s = late_s # EV-20: Solar holds, then the stale rule
self._car_late_mono = self._now_mono # EV-51: when that verdict was read
self._late_zero = late_s is not None and late_s >= stale_after
# ⚠️ `any`, NOT the sole unit's. The hold exists so a single missed
# poll does not become a fault; a LATCHED inverter must still reach the
+1 -1
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller
version: "0.24.0"
version: "0.25.0"
slug: goodwe_controller
description: >-
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port by sending it a
File diff suppressed because it is too large Load Diff
+45 -2
View File
@@ -137,11 +137,41 @@ class SunPlant:
return True
def _cycle_seconds(t0, dur, cyc, phase, jitter, cset):
"""EV-51: the seconds a cycle runs, or None for every second."""
if cset is not None:
due = {int(x) for x in cset if t0 <= x < t0 + dur}
if not due:
raise ValueError("cset has no second inside the run")
return due
if jitter is not None:
gaps = [int(g) for g in jitter]
if not gaps or min(gaps) <= 0:
raise ValueError("jitter needs gaps above 0")
due, t, i = set(), int(t0), 0
while t < t0 + dur:
due.add(t)
t += gaps[i % len(gaps)]
i += 1
return due
if cyc != int(cyc) or cyc <= 0:
raise ValueError("cyc must be a whole number of seconds above 0")
if not 0 <= phase < cyc:
raise ValueError("phase must be in [0, cyc)")
if cyc == 1:
return None
due = {int(t0) + k for k in range(int(phase), int(dur), int(cyc))}
if not due:
raise ValueError("no cycle inside the run")
return due
def drive(house, sun, *, dur=600.0, ratings=None, socs=None, cap=3500.0,
margin=100, opts=None, plug=True, setpoint=0, phases=1, mode="solar",
first="batteries", events=None, sim=None, store=None, race=False,
on_cycle=None, car_phases=3, t0=0.0, caps=None, finale=None,
rows=False, plant_cls=None, beside=False, meter_change=False):
rows=False, plant_cls=None, beside=False, meter_change=False,
cyc=1, phase=0, jitter=None, cset=None):
"""Run it. Returns a dict: plant, controller, charger, notifications with
their second, and a per-second trace. `caps` ({unit: kWh}) lets each
battery's level move with what it charges or gives; without it the
@@ -152,7 +182,14 @@ def drive(house, sun, *, dur=600.0, ratings=None, socs=None, cap=3500.0,
round 1): a write that waits for its read-back is still waiting when the
next cycle reads the charger; it resumes after that read.
`meter_change=True` publishes the meter as Home Assistant does on
`ha_signed`: only when the whole-watt value changes."""
`ha_signed`: only when the whole-watt value changes.
EV-51, the cycle's cadence (the meter and the charger model still tick
every 1 s; only the control cycle is thinned): `cyc` seconds between
cycles and `phase` (the first cycle at t0 + phase), or `jitter`, a
tuple of gaps used in turn (the first cycle at t0), or `cset`, the
cycle seconds. The default (1 s) runs every second as before. A cadence
that would run no cycle is a ValueError, never a vacuous pass."""
due = _cycle_seconds(t0, dur, cyc, phase, jitter, cset)
ratings = ratings or {"a": 5000.0, "b": 4600.0}
socs = socs or {u: 50.0 for u in ratings}
sim = sim or SimCharger(setpoint_a=setpoint)
@@ -252,6 +289,12 @@ def drive(house, sun, *, dur=600.0, ratings=None, socs=None, cap=3500.0,
"ha_signed", imp, exp, phases=1,
ingest_ts=rig.BASE + timedelta(seconds=ts),
ingest_mono=ts))
if due is not None and int(t) not in due:
for u, kwh in (caps or {}).items():
lv = plant.socs[u] - plant.batt_of(u, t) / 36000.0 / kwh
plant.socs[u] = max(0.0, min(100.0, lv))
t += 1.0
continue
await c.read_inputs(now_mono=t)
if race:
await c.car_settle()