Compare commits

...
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5.5 55a6d5dcdb SAFETY-40 review: integrator-bound WARNING gets its own notification id
checks / unit (pull_request) Successful in 8m46s
infra-pin / fresh (pull_request) Successful in 1s
A later anti-windup notice could replace a write-path BUG SIGNAL notice
under the shared goodwe_output_clamp id (escalation ignores the budget).
The WARNING now uses goodwe_integrator_bound and points to DOCS; the
cadence sentence in DOCS is corrected. Tests pin both ids (red on fd14569).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 23:08:44 +02:00
glenn schrooyenandClaude Opus 5.5 fd14569a71 SAFETY-40: the integrator bound is not a BUG SIGNAL; numbers from the clamp tick
checks / unit (pull_request) Successful in 8m47s
infra-pin / fresh (pull_request) Successful in 1s
The clamp alarm gave `i_clamped` (normal anti-windup) the over-rating BUG
SIGNAL text, printed `Decision.i_w` as "the loop asked for", and printed
`self.target` (after slew/freeze) as "was clamped to".

- clamp.loop_clamp_note(): i_clamped says "the loop's integrator reached its
  N W anti-windup bound" with this tick's command; clamped keeps BUG SIGNAL
  with the requested command and the clamp's own result.
- Decision carries i_bound_w / requested_w / clamped_w, set at the clamp.
- i_clamped still counts and notifies (same id, cadence, SAFETY-41
  escalation) but as a WARNING, amber row, plain title. A bug has its own
  notification budget and its text is not overwritten within an episode.
- test_clamp.py part 9: red on the old code per defect; 5 mutations killed.
- DOCS.md alarm section (and its stale 30 s cadence), DECISIONS/SAFETY-40.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-26 22:37:01 +02:00
admin 59415ea83f Merge pull request 'CI: bump infra pin to 7689816 (admin/goodwe#58, SAFETY-34)' (#129) from pin-bump-7689816 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-09-26 16:15:23 +02:00
glenn schrooyenandClaude Opus 5.5 f37268f3e4 CI: bump infra pin to 7689816 (admin/goodwe#58, SAFETY-34)
checks / unit (pull_request) Successful in 8m48s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 16:05:02 +02:00
admin 397dd15dba SAFETY-34: re-assert latched alarms after a Core-only restart (#128)
infra-pin / fresh (push) Failing after 1s
2026-09-26 16:03:16 +02:00
glenn schrooyenandClaude Opus 5.5 6028e21298 SAFETY-34: re-assert latched alarms, because a Core restart keeps the add-on
checks / unit (pull_request) Successful in 8m55s
infra-pin / fresh (pull_request) Successful in 1s
A Core-only restart wipes persistent_notification and does NOT restart the
add-on (measured on TEST-23: the add-on's SAFETY-31 card was gone 4 min after
`docker restart test23-ha`, add-on StartedAt unchanged). The latched SAFETY-31
and SAFETY-42 cards were re-raised only on add-on start, so they stayed gone.

They are now re-asserted every REANNOUNCE_S = 300 s while tripped (same
notification_id, so it replaces). test_watchdog part 6 and test_delivery part
8b grade it with the same process across the "restart"; red on the old code.
The docstrings that said the add-on restarts with HA are corrected.
Record: goodwe docs/DECISIONS.md, SAFETY-34 D4.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-26 12:37:47 +02:00
admin fe132515fe Merge pull request 'CI: bump infra pin to a1d0618 (admin/goodwe#57, TOOL-9)' (#127) from pin-bump-a1d0618 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 20:52:59 +02:00
glenn schrooyenandClaude Opus 5.5 00e9a7b4e1 CI: bump infra pin to a1d0618 (admin/goodwe#57, TOOL-9)
checks / unit (pull_request) Successful in 8m46s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 20:42:44 +02:00
admin 82f032e8cf Merge pull request 'TOOL-9: pin checks print FAIL under pipefail; job tokens via header' (#126) from TOOL-9 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 20:39:47 +02:00
glenn schrooyenandClaude Opus 5.5 b963153de6 Restore .gitea/infra-pin (revert the TOOL-9 proof throwaway)
checks / unit (pull_request) Successful in 8m45s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 19:20:19 +02:00
glenn schrooyenandClaude Opus 5.5 a2c571b20e THROWAWAY (TOOL-9 proof, reverted next): remove .gitea/infra-pin
checks / unit (pull_request) Failing after 3s
infra-pin / fresh (pull_request) Failing after 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 19:08:22 +02:00
glenn schrooyenandClaude Opus 5.5 550bd6fa52 TOOL-9: pin checks print their FAIL line under pipefail; job tokens via header
checks / unit (pull_request) Failing after 3s
infra-pin / fresh (pull_request) Successful in 1s
A missing or comment-only .gitea/infra-pin now ends on the workflow's own
FAIL line instead of git's `fatal: path ... does not exist` (still red). Every
x-access-token remote URL becomes an env-set Authorization header, so no
token lands in .git/config or argv; the pin workflows' temp dir is removed
by an EXIT trap, also on failure.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-25 19:07:34 +02:00
admin 6a8a5ffa27 Merge pull request 'CI-12: CI grades test_freeze.py against the real hwsim at a pinned admin/goodwe' (#125) from CI-12 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 18:19:43 +02:00
13 changed files with 468 additions and 84 deletions
+1 -1
View File
@@ -1,2 +1,2 @@
# The admin/goodwe commit CI tests against. Bump: set to the full SHA of admin/goodwe release/1.0 HEAD (README.md, "CI and the infra pin").
2d026dfa7c425f462c6969b2f7cdfddc17b17a81
76898164b56190f0aa6f7a15be9ce6302c958ce5
+5 -3
View File
@@ -286,8 +286,9 @@ jobs:
run: |
set -eu
rm -rf "$WS" && mkdir -p "$WS/goodwe-addon" && cd "$WS/goodwe-addon"
git init -q .
git remote add origin "$(echo "$URL" | sed "s#://#://x-access-token:${TOKEN}@#")"
git init -q . && git remote add origin "$URL"
# Token as an env-set header: not in argv or .git/config (TOOL-9).
export GIT_CONFIG_COUNT=1 GIT_CONFIG_KEY_0=http.extraHeader GIT_CONFIG_VALUE_0="Authorization: token $TOKEN"
if [ -n "$PRNUM" ]; then
# Two fetches, not one, so that a failure to reach either ref fails
# HERE with the ref in the message, rather than inside the merge
@@ -498,7 +499,8 @@ jobs:
TOKEN: ${{ secrets.INFRA_READ_TOKEN }}
run: |
set -eu
PIN=$(grep -v '^#' "$WS/goodwe-addon/.gitea/infra-pin" | tr -d '[:space:]')
# `|| true`: under pipefail a missing or comment-only pin would skip the FAIL line (TOOL-9).
PIN=$(grep -v '^#' "$WS/goodwe-addon/.gitea/infra-pin" | tr -d '[:space:]') || true
echo "$PIN" | grep -Eq '^[0-9a-f]{40}$' || { echo "FAIL: .gitea/infra-pin holds '$PIN', not a full 40-hex SHA."; exit 1; }
test -n "$TOKEN" || { echo "FAIL: secret INFRA_READ_TOKEN is not available to this run (a fork PR?)."; exit 1; }
rm -rf "$WS/goodwe" && mkdir -p "$WS/goodwe" && cd "$WS/goodwe"
+10 -6
View File
@@ -23,16 +23,20 @@ jobs:
INFRA_TOKEN: ${{ secrets.INFRA_READ_TOKEN }} # admin/goodwe is private
run: |
set -eu
D=$(mktemp -d) && cd "$D"
git init -q . && git remote add origin "$(echo "$SELF" | sed "s#://#://x-access-token:${TOKEN}@#")"
D=$(mktemp -d) && trap 'cd / && rm -rf "$D"' EXIT && cd "$D"
git init -q .
# The pin of the commit this event is about (the PR head, or the push).
git fetch -q --depth 1 origin "$GITHUB_SHA"
PIN=$(git show FETCH_HEAD:.gitea/infra-pin | grep -v '^#' | tr -d '[:space:]')
# Token as an env-set header: not in argv or .git/config (TOOL-9).
GIT_CONFIG_COUNT=1 GIT_CONFIG_KEY_0=http.extraHeader GIT_CONFIG_VALUE_0="Authorization: token $TOKEN" \
git fetch -q --depth 1 "$SELF" "$GITHUB_SHA" || { echo "FAIL: could not fetch $GITHUB_SHA here."; exit 1; }
# `|| true`: under the runner's pipefail a missing or comment-only pin
# would stop here on git's error instead of the FAIL line below (TOOL-9).
PIN=$(git show FETCH_HEAD:.gitea/infra-pin | grep -v '^#' | tr -d '[:space:]') || true
test -n "$PIN" || { echo "FAIL: .gitea/infra-pin is missing at $GITHUB_SHA, or holds only comments."; exit 1; }
test -n "$INFRA_TOKEN" || { echo "FAIL: secret INFRA_READ_TOKEN is not available to this run (a fork PR?)."; exit 1; }
# Header via env, as in checks.yml: the token stays out of argv.
HEAD=$(GIT_CONFIG_COUNT=1 GIT_CONFIG_KEY_0=http.extraHeader GIT_CONFIG_VALUE_0="Authorization: token $INFRA_TOKEN" \
git ls-remote "$INFRA" refs/heads/release/1.0 | cut -f1)
cd / && rm -rf "$D"
git ls-remote "$INFRA" refs/heads/release/1.0 | cut -f1) || true
test -n "$HEAD" || { echo "FAIL: could not read admin/goodwe release/1.0."; exit 1; }
if [ "$PIN" != "$HEAD" ]; then
echo "STALE: .gitea/infra-pin is $PIN but admin/goodwe release/1.0 is $HEAD."
@@ -0,0 +1,28 @@
# SAFETY-40: the integrator bound is not a bug
**Decision.** `i_clamped` (the integrator reaching `integrator_max_w`, i.e.
anti-windup) keeps alarming through the same `ClampWatchdog`: it is counted,
notified on the same cadence, and escalates on a sustained run
(SAFETY-41). It gets its own text, a `WARNING` and an amber status row. Only
`clamped` (a command over `max_w`) and write-path clamps keep the BUG SIGNAL,
the `ERROR` and the red row.
**Why it still notifies.** On a default install `clamped` is unreachable
(`control.py`, at the integrator bound), so the integrator bound is the only
loop-side signal of a runaway such as the 14 768 W one. Silencing it would
remove that. The card says the same: "the fix is to say the true thing, not to
say less."
**Why a bug has its own budget.** A genuine over-rating must not wait up to
`REASSERT_S` behind anti-windup notices. `ClampWatchdog` tracks a separate
`last_bug_alarm`, and a bug's text is never overwritten by later anti-windup
text within an episode. Across episodes the WARNING uses its own
notification id (`goodwe_integrator_bound`), so it cannot replace a BUG SIGNAL
notice still on screen (review of #130). With only bug engagements, the cadence is the same as
before (`test_clamp.py` part 9).
**Numbers.** They come from the `Decision` of the clamping tick (`i_bound_w`,
`requested_w`, `clamped_w`, `target_w`), not from `i_w` or `self.target`.
**Open for the owner.** Whether scattered one-cycle anti-windup episodes should
notify at all, or only log and count. They notify now, as before.
+19 -4
View File
@@ -1630,7 +1630,9 @@ share no reason code, no notification id, no status row and no counter.
running - this is not the sign-disagreement failsafe, which commands 0 W. You
get a persistent notification (`goodwe_output_clamp`, replaced rather than
stacked), an `ERROR` in the log with the reason code `OUTPUT_CLAMP`, a row in
the event list, and a red status banner while it is engaged. Once it clears, a
the event list, and a red status banner while it is engaged. The message quotes
the command the loop computed and the value it was clamped to, both from the
cycle that clamped. Once it clears, a
warning row keeps the engagement count so the evidence does not vanish with the
condition. Consecutive engagements share one event row carrying the exact count,
because the event list keeps only 40 rows and a row per cycle would flush every
@@ -1639,9 +1641,11 @@ other guard's entries out of it.
**There is nothing to configure**, deliberately. The bound is `max_w`, which you
already set; giving the guard a limit of its own would be a second number that
can disagree with the first, which is exactly the failure the startup validation
exists to prevent. The alarm's cadence - first engagement, then re-asserted every
30 s while it persists, cleared after 3 clean cycles - is fixed for the same
reason `RAIL_FRAC` is: it describes the notification bus, not the plant.
exists to prevent. The alarm's cadence - normally at most one notification per
150 s (an episode that has not yet notified does so once it has engaged 3
cycles in a row, and an over-rating has its own 150 s budget), cleared after 3
clean cycles - is fixed for the same reason `RAIL_FRAC` is: it describes the
notification bus, not the plant.
WARNING: **on a default install the engagement you will see is the integrator's,
not the output's.** The control law bounds the integrator to `max_w` and *then*
@@ -1650,6 +1654,17 @@ rating unless `integrator_max_w` has been deliberately raised above `max_w`.
Both are watched. A guard that watched only the emitted value would be silent on
every standard configuration.
**The integrator bound is not a bug, and it is reported as what it is.** It
reads *"the loop's integrator reached its +5000 W anti-windup bound; the loop's
command this cycle was +2000 W"*, titled *"the control loop is at its integrator
bound"*, logged as a `WARNING`, with an amber (not red) status row and its own
notification (`goodwe_integrator_bound`), so it never replaces a BUG SIGNAL
notice still on screen. Brief
engagements after a large load or solar step are normal. If it stays engaged,
check that the battery is following its commands. Only a command over the rating
carries the BUG SIGNAL text, and it has its own notification budget.
Why: [`DECISIONS/SAFETY-40-the-integrator-bound-is-not-a-bug.md`](DECISIONS/SAFETY-40-the-integrator-bound-is-not-a-bug.md).
### The frozen-meter alarm
A meter that has died is easy — it stops answering, the sample age climbs past
+66 -20
View File
@@ -73,6 +73,7 @@ An alarm wired only to this module's `ClampResult.engaged` would therefore be
silent on the exact configuration the whole ticket is about. The winding is
visible one layer up, at the integrator bound, and that is why `Decision` now
carries `i_clamped` / `clamped` BOOLEANS and the caller ORs them in here.
They alarm in different words: see `loop_clamp_note()` (SAFETY-40).
AND WHY BOOLEANS RATHER THAN `Decision.reason`. `reason` is a single string that
later stages overwrite: a cycle that clamps the integrator and is then slew
@@ -200,9 +201,8 @@ REASON_CODE = "OUTPUT_CLAMP"
# ceiling rests on one number a test author chose; if that number is ever
# revisited, this constant moves with it.
#
# ⚠️ THIS IS A STOP-GAP AND DOES NOT MAKE THE ALARM CORRECT. The message still
# calls the integrator bound a BUG SIGNAL and still pairs a request from one
# moment with a `self.target` read at another - SAFETY-40. Nothing here is
# ⚠️ THIS WAS A STOP-GAP; the wording and the numbers were SAFETY-40's, fixed
# in `loop_clamp_note()` below. Nothing here is
# suppressed: every engagement is still counted, the action-log row is written on
# every engaged cycle regardless, and the rising edge of every episode alarms
# unconditionally, so no alarm is DROPPED - only delayed.
@@ -234,6 +234,31 @@ CLEAR_CYCLES = 3
SUSTAINED_CYCLES = 3
BUG_SIGNAL = ("This is a BUG SIGNAL, not a limit being used: something "
"upstream computed a setpoint the actuator cannot deliver.")
def loop_clamp_note(d) -> str:
"""The loop-side alarm text for one `control.Decision`, or "".
SAFETY-40: the integrator bound is anti-windup doing its job and says so;
only a command over the rating is a BUG SIGNAL. Every number is the
decision's own, i.e. from the tick that clamped.
"""
if d.clamped:
return (f"{REASON_CODE}: the loop computed {d.requested_w:+.0f} W, over "
f"the {abs(d.clamped_w):.0f} W rating, and it was clamped to "
f"{d.clamped_w:+.0f} W; the loop's command this cycle was "
f"{d.target_w:+.0f} W. {BUG_SIGNAL}")
if d.i_clamped:
return (f"{REASON_CODE}: the loop's integrator reached its "
f"{d.i_bound_w:+.0f} W anti-windup bound; the loop's command "
f"this cycle was {d.target_w:+.0f} W. Brief "
f"engagements after a large load or solar step are normal. If it "
f"persists, check that the battery is following its commands.")
return ""
@dataclass(frozen=True)
class ClampResult:
"""What the guard did, with the RAW value preserved.
@@ -342,23 +367,51 @@ class ClampWatchdog:
# spoken yet - the two the escalation clause needs.
self.run_len = 0
self.spoken = False
# SAFETY-40. Did this episode include a genuine over-rating (`bug`), and
# has THAT spoken? A bug has its own budget, so anti-windup notices can
# never delay it; with bug=True throughout, cadence is as before.
self.bug = False
self.bug_spoken = False
self.last_bug_alarm: datetime | None = None
def note(self, engaged: bool, reason: str, now: datetime) -> bool:
def _due(self, last, now) -> bool:
return last is None or (now - last).total_seconds() >= REASSERT_S
def _speak(self, now, bug) -> bool:
self.last_alarm = now
self.spoken = True
if bug:
self.last_bug_alarm = now
self.bug_spoken = True
return True
def note(self, engaged: bool, reason: str, now: datetime,
bug: bool = True) -> bool:
"""Advance one cycle. True when the caller should raise the alarm.
`now` is the caller's clock, the same discipline as
`SignWatchdog.evaluate()` and `FreezeWatchdog.evaluate()`.
`SignWatchdog.evaluate()` and `FreezeWatchdog.evaluate()`. `bug` False
is the integrator bound (SAFETY-40): counted and notified like the
rest, but it never replaces a bug's text within an episode.
"""
if engaged:
self.engagements += 1
self.clean_cycles = 0
self.reason = reason
self.run_len += 1
if not self.active:
rising = not self.active
if rising:
self.active = True
self.since = now
self.episodes += 1
self.spoken = False
self.bug = False
self.bug_spoken = False
if bug or not self.bug:
self.reason = reason
self.bug = self.bug or bug
if bug and not self.bug_spoken and self._due(self.last_bug_alarm, now):
return self._speak(now, True)
if rising:
# ⚠️ SAFETY-41. THE RISING EDGE IS RATE-LIMITED TOO, and it did
# not used to be. It fired unconditionally, so a condition that
# engages and clears repeatedly raised one notification PER
@@ -384,11 +437,8 @@ class ClampWatchdog:
# still written on every engaged cycle, and a genuine runaway -
# which by definition keeps engaging - is picked up by the
# re-assert path within REASSERT_S. Delay, not loss.
if (self.last_alarm is None
or (now - self.last_alarm).total_seconds() >= REASSERT_S):
self.last_alarm = now
self.spoken = True
return True
if self._due(self.last_alarm, now):
return self._speak(now, self.bug)
return False
# ⚠️ THE ESCALATION. An episode that has not yet spoken because the
# budget was spent by an EARLIER, unrelated episode speaks anyway
@@ -396,15 +446,10 @@ class ClampWatchdog:
# engages every cycle and reaches it; the scattered one-cycle
# railing that produced the live flood never does.
if not self.spoken and self.run_len >= SUSTAINED_CYCLES:
self.last_alarm = now
self.spoken = True
return True
return self._speak(now, self.bug)
# Still engaged: re-assert on the slow cadence, not every cycle.
if (self.last_alarm is None
or (now - self.last_alarm).total_seconds() >= REASSERT_S):
self.last_alarm = now
self.spoken = True
return True
if self._due(self.last_alarm, now):
return self._speak(now, self.bug)
return False
self.run_len = 0
@@ -420,5 +465,6 @@ class ClampWatchdog:
# above. The episode ends; the notification budget does not reset
# with it.
self.reason = ""
self.bug = False
self.clean_cycles = 0
return False
+10 -1
View File
@@ -340,6 +340,12 @@ class Decision:
# the comment at the bound below, and clamp.py.
i_clamped: bool = False
clamped: bool = False
# SAFETY-40. The alarm's numbers, taken at the clamp so they are one tick's:
# the bound the integrator reached, and the command before/after the
# rating clamp. `target_w` is this tick's emitted command.
i_bound_w: float = 0.0
requested_w: float = 0.0
clamped_w: float = 0.0
def slew_limit_w(tuning: Tuning) -> float:
@@ -563,6 +569,7 @@ def compute(
# winding, "clamped" is a command that came out over the rating anyway.
reason = "i-clamped"
i_w = bounded
i_bound_w = bounded if i_clamped else 0.0
want = i_w
# ⚠️ Maintenance shaping (charge-only, cheap-window floor) used to live
@@ -574,6 +581,7 @@ def compute(
# An early draft applied a floor after the clamp and let demand escape it.
target = max(-tuning.max_w, min(tuning.max_w, want))
clamped = target != want
clamped_w = target
if clamped:
reason = "clamped"
@@ -740,7 +748,8 @@ def compute(
target = round(target / step) * step
return Decision(float(target), sat_count, frozen, reason, float(i_w),
i_clamped, clamped)
i_clamped, clamped, float(i_bound_w), float(want),
float(clamped_w))
def maintenance_charge_floor(
+70 -29
View File
@@ -49,7 +49,8 @@ from .circulation import (
circulating_w, opposing,
)
from .clamp import (
REASON_CODE as CLAMP_REASON, ClampWatchdog, clamp_to_rating, is_commandable,
BUG_SIGNAL as CLAMP_BUG_SIGNAL, REASON_CODE as CLAMP_REASON, ClampWatchdog,
clamp_to_rating, is_commandable, loop_clamp_note,
)
from . import freshness
from .freeze import (
@@ -113,6 +114,12 @@ __all__ = ["UNIT_A", "Controller", "amain", "main"]
# the re-issue happens by itself) than hold the control loop for ten seconds.
WRITE_BUDGET_S = 4.0
# SAFETY-34: a Core-only restart wipes persistent_notification and does NOT
# restart this add-on (measured on TEST-23), so a latched alarm is re-asserted
# this often. Why: goodwe docs/DECISIONS.md, SAFETY-34.
REANNOUNCE_S = 300.0
_mono = time.monotonic # patched by the checks; asyncio keeps the real one
# --------------------------------------------------------------------------- #
# OPT-04: THE BACKGROUND TARIFF REFRESH, AND WHY IT IS NOT OPTIONAL
#
@@ -691,6 +698,9 @@ class Controller:
# does, so the latch alone is not the alarm - re-raising it is.
# `run_control()` does that, once, before the first cycle.
self._circ_announced = False
# SAFETY-34: when each latched alarm was last put in front of HA, by
# notification_id - see REANNOUNCE_S.
self._announced_mono = {}
if self.circ_wd.tripped:
_LOG.error(
"SAFETY-31 was TRIPPED before this restart and stays tripped: "
@@ -985,7 +995,8 @@ class Controller:
# the counterpart to `clamp_last` moving onto the Inverter: the integrator
# that wound is the SITE integrator, of which there is exactly one, while
# the value a clamp bit is a value written to ONE device.
self.loop_clamped: tuple[bool, str] = (False, "")
# (engaged, note, over_rating) - SAFETY-40 splits the last one out.
self.loop_clamped: tuple[bool, str, bool] = (False, "", False)
self.stopping = False
# SAFETY-61. time.monotonic() at the end of the last run_control() pass.
self.loop_pass_mono = None
@@ -3262,11 +3273,12 @@ class Controller:
# it - so a string test is silent on the two cases a winding loop
# most often presents as. These flags are set where the clamp
# happens and nothing downstream touches them.
# SAFETY-40: every number comes from THIS decision, at clamp time,
# never from `self.target` after slew/freeze/arbiter rewrote it.
self.loop_clamped = (
decision.i_clamped or decision.clamped,
(f"the loop asked for {decision.i_w:+.0f} W"
+ (" (integrator bound)" if decision.i_clamped else "")
+ (" (output bound)" if decision.clamped else "")),
loop_clamp_note(decision),
decision.clamped,
)
# SITE. compute() regulates `grid_w` - the P1 measurement - to
# zero. Its subject is the meter, and §6.2's architecture is ONE
@@ -3290,7 +3302,7 @@ class Controller:
# A loop that is not running cannot be winding. Clearing this here
# rather than letting the last value stand is what makes the alarm
# de-assert when control is stopped.
self.loop_clamped = (False, "")
self.loop_clamped = (False, "", False)
# SAFETY-28. A new resolution is a new tick, and the previous record is
# stale from this line onwards. Incremented BEFORE resolve() so that the
@@ -3707,20 +3719,17 @@ class Controller:
clamped_units = [inv for inv in self.inverters
if inv.clamp_last is not None and inv.clamp_last.engaged]
engaged_write = bool(clamped_units)
engaged_loop, loop_note = self.loop_clamped
engaged_loop, loop_note, loop_bug = self.loop_clamped
engaged = engaged_write or engaged_loop
if engaged:
where = (", ".join(f"{inv.name}: {inv.clamp_last.describe()}"
for inv in clamped_units) if engaged_write
else f"{CLAMP_REASON}: {loop_note}, above the "
f"{self.site_max_w:.0f} W rating, and "
f"was clamped to {self.target:+.0f} W")
reason = (f"{where}. This is a BUG SIGNAL, not a limit being used: "
f"something upstream computed a setpoint the actuator "
f"cannot deliver.")
# SAFETY-40: only an over-rating is a bug; the integrator bound is not.
bug = engaged_write or loop_bug
if engaged_write:
reason = (", ".join(f"{inv.name}: {inv.clamp_last.describe()}"
for inv in clamped_units) + ". " + CLAMP_BUG_SIGNAL)
else:
reason = ""
fired = self.clamp_wd.note(engaged, reason, datetime.now(timezone.utc))
reason = loop_note if engaged else ""
fired = self.clamp_wd.note(engaged, reason, datetime.now(timezone.utc),
bug=bug)
# --- THE ACTION LOG, AND IT IS COALESCED PER EPISODE ------------------
# Every engagement is recorded, but consecutive ones are recorded by
@@ -3751,6 +3760,21 @@ class Controller:
self.log_event(row)
if not fired:
return
if not self.clamp_wd.bug:
# SAFETY-40: the integrator bound is anti-windup, not a bug - a
# WARNING and a plainly titled notice, same cadence. Its OWN id, so
# it can never replace a BUG SIGNAL notice still on screen.
_LOG.warning("SAFETY-03 - %s Engagements so far: %d.",
self.clamp_wd.reason, self.clamp_wd.engagements)
await self.hass.call("persistent_notification", "create", {
"notification_id": "goodwe_integrator_bound",
"title": "GoodWe: the control loop is at its integrator bound",
"message": (f"{self.clamp_wd.reason}\n\nNo command exceeded "
f"the rating and the controller is STILL RUNNING. "
f"See the add-on documentation, 'The winding-loop "
f"alarm'."),
})
return
_LOG.error(
"SAFETY-03 - %s Silently clipping this is how a winding integrator "
"reached 14 768 W on this project before: the clamp makes every "
@@ -3943,15 +3967,17 @@ class Controller:
The latch says "this site is tripped"; the flag says "this process has
put that in front of a human". A restart clears the flag and keeps the
latch, so the notification is RE-RAISED on the first cycle after every
add-on start - which is also the first cycle after a Home Assistant
restart, because the add-on is restarted with it.
add-on start. A Core-only restart does NOT restart the add-on, so it is
also re-asserted every REANNOUNCE_S (SAFETY-34).
⚠️ ONE CODE PATH FOR BOTH, ON PURPOSE. A fresh trip and a restart into
an existing trip raise the alarm through these same lines. Two paths
would be two chances for the restart one to rot unnoticed, and the
restart one is the case nobody exercises by hand.
"""
if not self.circ_wd.tripped or self._circ_announced:
if not self.circ_wd.tripped:
return
if self._circ_announced and not self._reannounce_due("goodwe_circulating_power"):
return
# Set BEFORE the await. `hass.call()` can raise or hang, and a retry
# every cycle for a broker that is down would be an alarm storm on the
@@ -3959,6 +3985,7 @@ class Controller:
# already durable and the log line above already fired; this surface is
# best-effort by design.
self._circ_announced = True
self._announced_mono["goodwe_circulating_power"] = _mono()
names = self.units
pos, neg = opposing([inv.batt for inv in self.inverters],
min_w=self.circ_wd.cfg.min_w / 2.0)
@@ -3993,6 +4020,11 @@ class Controller:
f"know why two inverters were opposing."),
})
def _reannounce_due(self, notification_id: str) -> bool:
"""SAFETY-34: has this latched alarm gone REANNOUNCE_S without being re-asserted?"""
t = self._announced_mono.get(notification_id)
return t is None or _mono() - t >= REANNOUNCE_S
async def check_not_delivering(self) -> None:
"""SAFETY-42 + SAFETY-34. The alarm, and it must survive a restart.
@@ -4012,8 +4044,8 @@ class Controller:
not persisted. The latch says "this unit is tripped"; membership says
"this process has put that in front of a human". A restart empties the
set and keeps the latch, so the notification is RE-RAISED on the first
cycle after every add-on start - which is also the first cycle after a
Home Assistant restart, because the add-on is restarted with it.
cycle after every add-on start, and re-asserted every REANNOUNCE_S
because a Core-only restart does not restart the add-on (SAFETY-34).
⚠️ ONE CODE PATH FOR BOTH, ON PURPOSE - `check_circulating()`'s
argument. A fresh trip and a restart into an existing trip raise the
@@ -4031,7 +4063,10 @@ class Controller:
names = self.units
slugs = unit_slugs(names)
for inv, slug in zip(self.inverters, slugs):
if not inv.delivery_wd.tripped or inv.name in self._delivery_announced:
nid = f"goodwe_not_delivering_{slug}"
if not inv.delivery_wd.tripped:
continue
if inv.name in self._delivery_announced and not self._reannounce_due(nid):
continue
# Added BEFORE the await, for `check_circulating()`'s reason:
# `hass.call()` can raise or hang, and a retry every cycle for a
@@ -4039,9 +4074,10 @@ class Controller:
# latch is already durable and the log line already fired; this
# surface is best-effort by design.
self._delivery_announced.add(inv.name)
self._announced_mono[nid] = _mono()
peers = ", ".join(n for n in names if n != inv.name) or "no sibling"
await self.hass.call("persistent_notification", "create", {
"notification_id": f"goodwe_not_delivering_{slug}",
"notification_id": nid,
"title": f"GoodWe: {inv.name} is not delivering its share",
"message": (
f"{inv.delivery_wd.reason}\n\nWHY NOTHING ELSE SAID SO. A "
@@ -4872,16 +4908,21 @@ class Controller:
out.append({"ok": False, "warn": "NOT COMMANDABLE" not in note,
"text": note})
# SAFETY-03. Red while a clamp is engaged, and the engagement COUNT is
# shown even after it clears - a loop that wound once and stopped is
# still a bug, and a row that vanishes with the condition takes the
# SAFETY-03. Red while an over-rating clamp is engaged (amber for the
# integrator bound, SAFETY-40), and the engagement COUNT is shown even
# after it clears - a row that vanishes with the condition takes the
# evidence with it. Reported only when there is something to report:
# unlike the freeze detector this guard has no "not covered" state, it
# runs on every write on every transport.
if self.clamp_wd.active:
if self.clamp_wd.active and self.clamp_wd.bug:
out.append({"ok": False, "warn": False,
"text": "OUTPUT CLAMP ENGAGED - " + self.clamp_wd.reason
+ f" Engagements: {self.clamp_wd.engagements}."})
elif self.clamp_wd.active:
# SAFETY-40: the integrator bound alone is amber, not red.
out.append({"ok": False, "warn": True,
"text": "LOOP AT INTEGRATOR BOUND - " + self.clamp_wd.reason
+ f" Engagements: {self.clamp_wd.engagements}."})
elif self.clamp_wd.engagements:
out.append({"ok": False, "warn": True,
"text": f"output clamp: not engaged now, but it has "
+3 -4
View File
@@ -62,10 +62,9 @@ the step it wants: if checks.yml is restructured so that the step cannot be
found, this file goes RED rather than quietly grading nothing.
⚠️ NEEDS `git`, which is why .gitea/ci/Dockerfile installs it. No network: the
fixtures are local repositories built in a temp directory, and the workflow's
`git remote add origin "$(echo "$URL" | sed "s#://#://x-access-token:...@#")"`
is a no-op substitution on a path with no `://` in it, which is what lets the
shipped line be used verbatim.
fixtures are local repositories built in a temp directory; the workflow's
token header (TOOL-9) is ignored for a local path, which is what lets the
shipped lines be used verbatim.
⚠️ This file writes only under a temporary directory. It must stay that way:
CI mounts the checkout READ-ONLY.
+193 -10
View File
@@ -38,6 +38,9 @@ acceptance criteria; part 6 is TEST-11's and part 7 is SAFETY-28's:
the check that replaced a config-shape proxy: `ACTUATOR_WRITE_KEYS` graded
how many option KEYS exist, which stays 1 while a per-inverter config adds
a second real writer.
9. SAFETY-40. The integrator bound (normal anti-windup) is reported in its
own words and never as a BUG SIGNAL; the over-rating keeps it; and every
number in either message is the clamp tick's own Decision.
------------------------------------------------------------------------------
WHY PART 4 ALSO ASSERTS ON `Decision`'s BOOLEANS AND NOT ON `reason`
@@ -99,6 +102,9 @@ T0 = datetime(2026, 8, 30, 9, 0, 0, tzinfo=timezone.utc)
# which is also the device rating, so this is the bound the alarm is written at.
LIVE_MAX_W = 5000.0
CLAMP_ID = "goodwe_output_clamp"
# SAFETY-40: the integrator-bound WARNING has its own id, so it can never
# replace a BUG SIGNAL notice still on screen.
BOUND_ID = "goodwe_integrator_bound"
def check(name, cond):
@@ -458,7 +464,7 @@ def wired(grid, cycles=40, batt=0.0, track=True, **over):
def clamp_notes(hass):
return [d for dom, svc, d in hass.calls
if (dom, svc) == ("persistent_notification", "create")
and d.get("notification_id") == CLAMP_ID]
and d.get("notification_id") in (CLAMP_ID, BOUND_ID)]
# THE 10.3 RUNAWAY, replayed. "With the inverter switched off entirely, an
@@ -497,12 +503,16 @@ print(f" the loop clamped on {ctl_r.clamp_wd.engagements} of {60} cycles, "
f"notification(s)")
check("AC 3: and it ALARMED - silently clipping this is the defect",
ctl_r.clamp_wd.engagements > 0 and len(notes_r) >= 1)
check("...with its own notification_id, not shared with any other guard",
all(d["notification_id"] == CLAMP_ID for d in notes_r))
check("...with its own notification_id, not shared with any other guard - "
"on a default install the integrator bound's (SAFETY-40)",
all(d["notification_id"] == BOUND_ID for d in notes_r))
check("...one episode, re-asserted rather than one per cycle",
ctl_r.clamp_wd.episodes == 1 and len(notes_r) < ctl_r.clamp_wd.engagements)
check("...and it names itself a bug signal, not a limit in use",
bool(notes_r) and "out of range" in notes_r[0]["message"])
# SAFETY-40: on a default install this runaway is the INTEGRATOR bound, so it
# says so, and does not call anti-windup a bug (part 8 grades the wording).
check("...and it names the integrator bound, not a BUG SIGNAL",
bool(notes_r) and "anti-windup bound" in notes_r[0]["message"]
and "BUG SIGNAL" not in notes_r[0]["message"])
rows_r = [e for e in ctl_r.events if REASON_CODE in e]
check(f"the action log records every engagement, coalesced into one row per "
f"episode ({len(rows_r)} row(s), {ctl_r.clamp_wd.engagements} "
@@ -528,8 +538,9 @@ check("...and the count in the row is the counter's, so nothing is lost",
f"{ctl_l.clamp_wd.engagements} engagement(s)" in nth(rows_l, -1))
# The RED row exists only while engaged, and the episode above is short, so it
# is captured mid-run rather than asserted after the hysteresis has cleared it.
check("the status page goes red WHILE it is engaged",
any(not c["ok"] and not c["warn"] and "OUTPUT CLAMP ENGAGED" in c["text"]
check("the status page flags it WHILE it is engaged - amber, since it is the "
"integrator bound (SAFETY-40; red is part 9's over-rating case)",
any(not c["ok"] and c["warn"] and "LOOP AT INTEGRATOR BOUND" in c["text"]
for c in ctl_r.red_snapshot))
check("...and once clear, a warn row still says how many times it engaged",
any(c["warn"] and f"{ctl_r.clamp_wd.engagements} time(s)" in c["text"]
@@ -806,11 +817,11 @@ class _SpyWatchdog(ClampWatchdog):
self.seen = [] # clamp_last.requested_w at each consultation
self.seen_write = [] # was the WRITE-path half engaged, per cycle
def note(self, engaged, reason, now):
def note(self, engaged, reason, now, **kw):
cl = self.owner.clamp_last
self.seen.append(None if cl is None else cl.requested_w)
self.seen_write.append(bool(cl and cl.engaged))
return super().note(engaged, reason, now)
return super().note(engaged, reason, now, **kw)
def probed(cls=Controller, grid=9000.0, cycles=5, **over):
@@ -986,7 +997,7 @@ check("PRECONDITION: the write really did clamp, on the DEVICE bound",
and hass_w.writes[-1] == 2500.0)
check("...and the loop-side half is SILENT here, so self.clamp_last is the "
"only evidence that this happened at all",
ctl_w.loop_clamped == (False, ""))
ctl_w.loop_clamped == (False, "", False))
check("AC 3: the guard alarmed on write-path evidence alone",
ctl_w.clamp_wd.engagements == 1 and len(notes_w) == 1)
check("...and the operator is told WHICH bound bit, so a device-rating clamp "
@@ -1858,6 +1869,178 @@ check("...EDGE-logged, not level-logged: 25 cycles did not flush the 40-row "
len(_shadow_lines) < 25 and len(_shad_c.events) <= 40)
# ==============================================================================
print()
print("9. SAFETY-40: the integrator bound is not a BUG SIGNAL, and the numbers "
"are the clamp tick's own")
# Three defects, each graded on the wired Controller.cycle() with compute()
# spied, so every number is compared with the Decision of the SAME tick:
# 1. `i_clamped` (normal anti-windup) used the over-rating BUG SIGNAL text;
# 2. "the loop asked for" printed `Decision.i_w`, the integrator, as a request;
# 3. "was clamped to" printed `self.target`, read after slew/freeze rewrote it.
# The fixtures are chosen so the numbers the old text used DIFFER from the true
# ones (MUTATION.md habit 4); the PRECONDITION checks pin that.
import logging
import app.main as _main_mod
_real_compute = _main_mod.compute
class _LogCap(logging.Handler):
def __init__(self):
super().__init__()
self.records = []
def emit(self, record):
self.records.append(record)
def s40_run(grid, cycles, track, **over):
"""Per tick: (Decision, self.target, clamp_wd.reason, engaged) + hass + log."""
ticks, decisions = [], []
def spy(*a, **k):
d = _real_compute(*a, **k)
decisions.append(d)
return d
cap = _LogCap()
lg = logging.getLogger("goodwe")
lg.addHandler(cap)
_main_mod.compute = spy
async def go():
hass = _Hass(grid, track=track)
c = Controller(dict(
{"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "max_w": LIVE_MAX_W, "gain": 0.6,
"slew_w": 1000, "deadband_w": 15, "target_grid_w": 0,
"step_w": 10, "heartbeat_s": 10, "stale_input_s": 15},
**over), hass, _Store(), _Pub(), stop=asyncio.Event())
c.auto = True
c.dev_min, c.dev_max = -LIVE_MAX_W, LIVE_MAX_W
red = []
for _ in range(cycles):
n = len(decisions)
before = c.clamp_wd.engagements
await c.read_inputs()
await c.cycle()
d = decisions[-1] if len(decisions) > n else None
ticks.append((d, c.target, c.clamp_wd.reason,
c.clamp_wd.engagements > before))
if c.clamp_wd.active and not red:
red = c.checks()
return hass, c, red
try:
hass, c, red = asyncio.run(go())
finally:
_main_mod.compute = _real_compute
lg.removeHandler(cap)
return ticks, hass, c, red, cap.records
def _f(d, name):
"""A Decision field, NaN when absent - so an old tree goes red, not crashes."""
return getattr(d, name, float("nan"))
# --- 9a. default install: only the INTEGRATOR bound can engage ---------------
ticks_i, hass_i, ctl_i, red_i, log_i = s40_run(6000.0, 20, track=False)
wind = [(d, t, r) for d, t, r, e in ticks_i
if e and d is not None and d.i_clamped and not d.clamped]
for d, t, r in wind:
print(f" tick: bound {_f(d, 'i_bound_w'):+.0f} i_w {d.i_w:+.0f} command "
f"{d.target_w:+.0f} self.target {t:+.0f}\n -> {r}")
check("PRECONDITION: the integrator bound engaged, and on a tick where the "
"carried integrator AND the emitted command both differ from the bound",
any(d.i_w != _f(d, 'i_bound_w') and d.target_w != _f(d, 'i_bound_w')
for d, t, r in wind))
check("defect 1: the integrator bound is NOT reported as a BUG SIGNAL",
wind and all("BUG SIGNAL" not in r for d, t, r in wind))
check("defect 1: ...it names the anti-windup bound, from the same tick",
wind and all(f"its {_f(d, 'i_bound_w'):+.0f} W anti-windup bound" in r
for d, t, r in wind))
check("defect 2: the integrator accumulator is not printed as a request",
wind and all(f"{d.i_w:+.0f} W" not in r and "asked for" not in r
for d, t, r in wind))
check("the command quoted is that tick's Decision, not a later read",
wind and all(f"command this cycle was {d.target_w:+.0f} W" in r
for d, t, r in wind))
check("at the bound nothing is described as 'above' or 'over' the rating",
wind and all(" above " not in r and " over " not in r
for d, t, r in wind))
notes_i = clamp_notes(hass_i)
check("it still NOTIFIES (not suppressed), under a title that claims no bug",
notes_i and all("integrator bound" in n["title"]
and "exceeded" not in n["title"] for n in notes_i))
check("...under its OWN notification_id, so it cannot replace a BUG SIGNAL "
"notice still on screen",
notes_i and all(n["notification_id"] == BOUND_ID for n in notes_i))
check("...logged as a WARNING, not an ERROR",
any(x.levelno == logging.WARNING and "anti-windup" in x.getMessage()
for x in log_i)
and not any(x.levelno >= logging.ERROR and "OUTPUT_CLAMP" in x.getMessage()
for x in log_i))
check("...and the status row is amber, not red",
any(c["warn"] and "LOOP AT INTEGRATOR BOUND" in c["text"] for c in red_i)
and not any(not c["warn"] and "OUTPUT CLAMP ENGAGED" in c["text"]
for c in red_i))
# --- 9b. the genuine over-rating: integrator_max_w above max_w ----------------
ticks_o, hass_o, ctl_o, red_o, log_o = s40_run(9000.0, 12, track=True,
integrator_max_w=9000)
over = [(d, t, r) for d, t, r, e in ticks_o
if e and d is not None and d.clamped]
for d, t, r in over[:2]:
print(f" tick: requested {_f(d, 'requested_w'):+.0f} clamped {_f(d, 'clamped_w'):+.0f}"
f" i_w {d.i_w:+.0f} self.target {t:+.0f}\n -> {r}")
check("PRECONDITION: the output clamp engaged on a tick where the slew limit "
"rewrote the command AND the integrator differs from the request",
any(t != _f(d, 'clamped_w') and d.i_w != _f(d, 'requested_w') for d, t, r in over))
check("the over-rating KEEPS the BUG SIGNAL",
over and all("BUG SIGNAL" in r for d, t, r in over))
check("defect 2: it quotes the requested COMMAND of that tick, not i_w",
over and all(f"computed {_f(d, 'requested_w'):+.0f} W" in r for d, t, r in over))
check("defect 3: 'clamped to' is the clamp's own result, not self.target",
over and all(f"clamped to {_f(d, 'clamped_w'):+.0f} W" in r for d, t, r in over))
check("...and the 14 768 W rationale is still in its ERROR",
any(x.levelno == logging.ERROR and "14 768 W" in x.getMessage()
for x in log_o))
check("...under the 'exceeded the rating' title, with a red status row",
clamp_notes(hass_o)
and all("exceeded the rating" in n["title"]
and n["notification_id"] == CLAMP_ID for n in clamp_notes(hass_o))
and any(not c["warn"] and "OUTPUT CLAMP ENGAGED" in c["text"]
for c in red_o))
# --- 9c. the text, directly, and the two budgets -------------------------------
from app.clamp import loop_clamp_note # noqa: E402
d_at = compute(prev_w=1000.0, grid_w=9000.0, actual_w=1000.0,
tuning=Tuning(max_w=5000.0, slew_w=1000.0, gain=0.6), i_w=4500.0)
check(f"exactly at the rating ({d_at.i_bound_w:+.0f} W) is 'reached', never "
f"'above' - {loop_clamp_note(d_at)!r}",
d_at.i_clamped and not d_at.clamped and abs(d_at.i_bound_w) == 5000.0
and "above" not in loop_clamp_note(d_at))
check("a healthy decision produces no text",
loop_clamp_note(compute(0.0, 100.0, 0.0, Tuning(max_w=5000.0))) == "")
# Anti-windup notices must never spend the budget a BUG SIGNAL needs.
wd = ClampWatchdog()
fired_w = wd.note(True, "wind", T0, bug=False)
fired_b = wd.note(True, "bug", T0 + timedelta(seconds=5), bug=True)
wd.note(True, "wind again", T0 + timedelta(seconds=10), bug=False)
check("an anti-windup notice does not delay a bug in the same episode, and "
"does not overwrite its text",
fired_w and fired_b and wd.bug and wd.reason == "bug")
wd2 = ClampWatchdog()
seq = [wd2.note(True, "b", T0 + timedelta(seconds=5 * i)) for i in range(40)]
check("bug-only cadence is unchanged: rising edge, then every REASSERT_S",
seq[0] and sum(seq) == 1 + int(5 * 39 // REASSERT_S))
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
+36 -2
View File
@@ -1195,8 +1195,8 @@ async def _restart():
c1 = _ctrl(h1, store=shared)
await _drive(c1)
# A NEW process, a NEW HomeAssistant object (so the in-memory notification
# is gone with it), the SAME durable file. That is what a Home Assistant
# restart is from this add-on's point of view: the add-on goes with it.
# is gone with it), the SAME durable file: an ADD-ON restart. A Core-only
# restart keeps the process; graded in part 8b (SAFETY-34).
h2 = _DeliveryHass(b_soc=50.0)
c2 = _ctrl(h2, store=shared)
await c2.check_not_delivering()
@@ -1250,6 +1250,40 @@ check("the operator's START press is the only way out, and it clears the "
and _rs.data.get(unit_key("inverter-b", "delivery_reason")) == ""
and _r2._delivery_announced == set())
print()
print("8b. SAFETY-34: a Core-only restart - same add-on process, HA's memory wiped")
import app.main as _main_mod # noqa: E402
async def _core_restart():
shared = _MemStore()
c = _ctrl(_DeliveryHass(b_soc=50.0), store=shared)
await _drive(c)
return c
_c = asyncio.run(_core_restart())
_real_mono, _clock = _main_mod._mono, [_main_mod._mono()]
_main_mod._mono = lambda: _clock[0]
try:
_c.hass = _DeliveryHass(b_soc=50.0)
asyncio.run(_c.check_not_delivering())
_early = [x for x in _c.hass.calls
if "not_delivering" in str(x[2].get("notification_id", ""))]
_clock[0] += _main_mod.REANNOUNCE_S
asyncio.run(_c.check_not_delivering())
_late = [x for x in _c.hass.calls
if "not_delivering" in str(x[2].get("notification_id", ""))]
finally:
_main_mod._mono = _real_mono
check("SAFETY-34: the latch tripped in this process",
_c.inverters[1].delivery_wd.tripped)
check("SAFETY-34: inside REANNOUNCE_S the same process does not re-raise",
len(_early) == 0)
check("SAFETY-34: after REANNOUNCE_S the SAME process re-asserts the card, "
"because a Core-only restart wiped it and did not restart the add-on",
len(_late) == 1 and "inverter_b" in _late[0][2]["notification_id"])
print()
if fails:
+3 -2
View File
@@ -835,7 +835,8 @@ frozen_rows = [c for c in ctl_f.checks() if "METER MAY BE FROZEN" in c["text"]]
print(f" frozen at +4000 W: command ran to {ctl_f.target:.0f} W, "
f"{len(notes)} notification(s), {len(frozen_rows)} red status row(s)")
# SURFACE-WIDE, deliberately, and the second guard has now landed. SAFETY-03
# ships `goodwe_output_clamp`, and this scenario - a runaway loop winding into
# ships `goodwe_output_clamp` (and, for the integrator bound on a default
# install, `goodwe_integrator_bound` - SAFETY-40), and this scenario - a runaway loop winding into
# the rail - raises it legitimately: the loop asks for more than the rating and
# is clamped. So the answer to "is this scenario still meant to raise exactly
# one alarm" is NO, it raises exactly two, and BOTH ARE NAMED here rather than
@@ -846,7 +847,7 @@ _ids = sorted(d.get("notification_id") for d in all_notes)
print(f" the whole notification surface this run: {_ids}")
check("the whole notification surface carried exactly two alarms this run - "
"SAFETY-18's and SAFETY-03's, both named",
_ids == ["goodwe_meter_frozen", "goodwe_output_clamp"])
_ids == ["goodwe_integrator_bound", "goodwe_meter_frozen"])
# THIS GUARD'S, keyed on the id.
check("...and the freeze detector is the one that raised it", len(notes) == 1)
# ⚠️ Selected by TEXT, not by id - see notes_by_text_of(). One of the two
+24 -2
View File
@@ -1055,8 +1055,8 @@ async def _circ_restart():
await a.read_inputs()
await a.cycle()
await asyncio.sleep(0.25)
# THE RESTART. Same store, brand new Controller and Hass - which is exactly
# what a Home Assistant restart does to this add-on. The house has stopped
# THE RESTART. Same store, brand new Controller and Hass - an ADD-ON
# restart. A Core-only restart keeps the process; graded below (SAFETY-34). The house has stopped
# circulating in the meantime, so nothing in the new process's own
# measurements could re-derive the trip.
h2 = _CircHass(a_w=0.0, b_w=0.0)
@@ -1116,6 +1116,28 @@ check("...and it does not raise the same card on every cycle - a per-PROCESS "
"this' a different question from 'is this site tripped'",
len(_notes2) == 1)
# SAFETY-34: a Core-ONLY restart. The add-on process lives on (measured on
# TEST-23), HA's memory is wiped, so the SAME process must re-assert the card.
import app.main as _main_mod # noqa: E402
_real_mono, _clock = _main_mod._mono, [_main_mod._mono()]
_main_mod._mono = lambda: _clock[0]
try:
_h3 = _CircHass(a_w=0.0, b_w=0.0)
_b.hass = _h3
asyncio.run(_b.check_circulating())
_early = [c for c in _h3.calls if c[0] == "persistent_notification"]
_clock[0] += _main_mod.REANNOUNCE_S
asyncio.run(_b.check_circulating())
_late = [c for c in _h3.calls if c[0] == "persistent_notification"]
finally:
_main_mod._mono = _real_mono
check("SAFETY-34: inside REANNOUNCE_S the same process does not re-raise - no "
"storm on the event bus", len(_early) == 0)
check("SAFETY-34: a Core-only restart wipes the card and the add-on process "
"survives it, so after REANNOUNCE_S the SAME process re-asserts it",
len(_late) == 1
and _late[0][2]["notification_id"] == "goodwe_circulating_power")
print()