@@ -0,0 +1,10 @@
|
||||
# This add-on is deployed to a Linux container. core.autocrlf=true on the
|
||||
# authoring box gave the checkout CRLF, so a plain copy shipped CRLF files -
|
||||
# run.sh with CRLF is a "bad interpreter" failure, and any hash-based drift
|
||||
# check between repo and deployment fails for a reason that has nothing to do
|
||||
# with the code. Deploy with:
|
||||
# git -c core.autocrlf=false archive release/1.0 goodwe_controller | tar -x
|
||||
# which is how 0.3.0 went out, byte-identical to the blobs.
|
||||
* text=auto eol=lf
|
||||
*.png binary
|
||||
*.gz binary
|
||||
@@ -1,5 +1,75 @@
|
||||
# Changelog
|
||||
|
||||
## Unreleased
|
||||
|
||||
**TEL-04.** A third `meter_source`, `ha_signed`, reading **one signed** Home
|
||||
Assistant entity: positive = import, negative = export. That is the shape a
|
||||
HomeWizard P1 publishes (`sensor.p1_meter_active_power`), and it is the meter
|
||||
actually fitted here - which neither TEL-01 transport can read, because
|
||||
`ha_dsmr` needs two unsigned registers and refuses a negative one, i.e. every
|
||||
exporting telegram. Set `p1_net_entity`, and `p1_phase_net_entities` for the
|
||||
per-phase capacity-tariff figures on a three-phase connection.
|
||||
|
||||
Everything TEL-01 established is inherited rather than re-implemented - the
|
||||
new transport is a subclass of the `ha_dsmr` one overriding only which
|
||||
entities it wants and how they become a sample. So ingest timestamping,
|
||||
`meter_max_age_s`, `sensor.p1_sample_age_s` recomputed against the clock and
|
||||
republished once a second, the plausibility bounds, and `unavailable` /
|
||||
`unknown` treated as a *missing reading and never 0 W* all behave identically
|
||||
across the three sources.
|
||||
|
||||
Still defaults to `off`; an existing install is unaffected until it opts in.
|
||||
|
||||
⚠️ **`sensor.p1_sample_age_s` is published on `ha_signed`, but must not yet be
|
||||
thresholded by the ESP32 stale-input watchdog.** On the HA WebSocket paths the
|
||||
age is stamped from `state_changed`, so it measures time since the value
|
||||
*changed*, not since the meter *reported* - and Home Assistant exposes no
|
||||
arrival signal for a repeated reading (no `state_changed`, no `last_reported`
|
||||
movement on either serialiser, and `state_reported` is not subscribable over
|
||||
the WebSocket). Measured on the ENV-01 rig against the real HomeWizard
|
||||
integration. `ha_dsmr` mostly escapes it because a telegram moves several
|
||||
entities at once; `ha_signed` has one, so a healthy meter under a flat load is
|
||||
indistinguishable from a dead one. Our own capture has the house meter going
|
||||
42.2 s and 97.0 s between changes. Raising `meter_max_age_s` does not fix that,
|
||||
it only chooses which error you get; the fix is an arrival stamp from the meter
|
||||
itself and is a separate ticket. Full detail in DOCS.md.
|
||||
|
||||
## 0.3.0
|
||||
|
||||
**SAFETY-04.** The control law's integrator is now an explicit accumulator,
|
||||
bounded independently of the output clamp instead of inheriting whatever
|
||||
headroom the clamp happened to leave. It also freezes while the inverter is
|
||||
not tracking, rather than continuing to wind up against a command nothing is
|
||||
acting on. `integrator_max_w` (default `0`) governs the bound; `0` means
|
||||
"follow `max_w`", which is the existing behaviour.
|
||||
|
||||
Behaviour is unchanged at the defaults - a 4,928-case equivalence sweep
|
||||
against the previous control law confirms it decides identically at
|
||||
`integrator_max_w: 0`.
|
||||
|
||||
**TEL-01.** P1 meter ingestion, so a Belgian P1's two unsigned registers
|
||||
(consumption, injection) no longer need a hand-written signed template
|
||||
sensor: the subtraction moves into the add-on, done once and tested. Two
|
||||
transports, chosen with the new `meter_source` option: `ha_dsmr` subscribes
|
||||
to the DSMR integration over the HA WebSocket, `mqtt_p1` reads a topic.
|
||||
Defaults to `off`, which keeps the existing `meter_entity` path untouched -
|
||||
nothing changes for an install that does not opt in.
|
||||
|
||||
Enabling it publishes `sensor.p1_sample_age_s`: seconds since the newest
|
||||
accepted telegram, recomputed against the clock and republished roughly once
|
||||
a second rather than only when a telegram lands. That is deliberate - Home
|
||||
Assistant only pushes a state on change, so a meter sitting at a genuinely
|
||||
constant reading would otherwise look identical to a dead one. Watching the
|
||||
age instead means a frozen meter shows a climbing age, not a flat line. The
|
||||
firmware watchdog subscribes to this exact entity id.
|
||||
|
||||
Known limits, both already in DOCS.md: on `mqtt_p1`, a bridge stuck
|
||||
republishing its last telegram still "arrives", so the age cannot detect
|
||||
that particular failure - prefer `ha_dsmr` where both are available. And a
|
||||
dead P1 meter takes 45 s to reach 0 W commanded (30 s for `meter_max_age_s`
|
||||
to call the reading stale, then 15 s of `stale_input_s` on top), which is
|
||||
`meter_max_age_s` and `stale_input_s` stacking, not either one alone.
|
||||
|
||||
## 0.2.1
|
||||
|
||||
`target_grid_w` (default -10 W): what the meter should rest at. The deadband
|
||||
|
||||
+122
-9
@@ -51,21 +51,75 @@ phase having charged nothing.
|
||||
### P1 meter ingestion
|
||||
|
||||
`meter_entity` above expects one signed sensor, which usually means a template
|
||||
someone wrote by hand. A Belgian P1 meter does not publish one: it publishes two
|
||||
**unsigned** registers, consumption and injection. Setting `meter_source` moves
|
||||
that subtraction into the add-on, where it is done once and tested, and replaces
|
||||
`meter_entity` entirely.
|
||||
someone wrote by hand. Setting `meter_source` moves the whole derivation into
|
||||
the add-on, where it is done once and tested, and replaces `meter_entity`
|
||||
entirely.
|
||||
|
||||
Which mode you want depends on what your P1 reader publishes, and there are two
|
||||
shapes in the wild:
|
||||
|
||||
- **Two unsigned registers**, consumption and injection, which is what a Belgian
|
||||
P1 read over DSMR gives you → `ha_dsmr`, or `mqtt_p1` for a bridge. The add-on
|
||||
subtracts them.
|
||||
- **One signed figure**, positive = import and negative = export, which is what
|
||||
a HomeWizard P1 gives you (`sensor.p1_meter_active_power`) → `ha_signed`. The
|
||||
add-on splits it. `ha_dsmr` **cannot** read this: it wants two registers and
|
||||
rejects a negative one outright, which is every exporting telegram.
|
||||
|
||||
Either way, do not build the missing shape out of template sensors. The point of
|
||||
`meter_source` is that the sign convention is derived in one tested place rather
|
||||
than in YAML nobody reviews underneath a safety input.
|
||||
|
||||
> ⚠️ **`ha_dsmr` and `mqtt_p1` have never processed a telegram from real
|
||||
> hardware.** No meter in this installation uses either one. Both were written
|
||||
> to the assumption in `specs.md` §5.2 that a Belgian P1 exposes two unsigned
|
||||
> registers, and the meter actually fitted here does not — it is the HomeWizard
|
||||
> P1 that `ha_signed` reads. They are covered by the unit checks in `test_p1.py`
|
||||
> and by an end-to-end test against a fake Home Assistant, and nothing more.
|
||||
>
|
||||
> This is recorded because the realistic way it bites is someone debugging a
|
||||
> meter problem months from now treating those two paths as proven and looking
|
||||
> for the fault elsewhere. If you are the first person to point one at a real
|
||||
> meter, expect to find something, and please update this note when you do.
|
||||
|
||||
| option | default | meaning |
|
||||
|---|---|---|
|
||||
| `meter_source` | `off` | `off` keeps `meter_entity`. `ha_dsmr` subscribes to the DSMR integration over the HA WebSocket; `mqtt_p1` reads a topic |
|
||||
| `meter_source` | `off` | `off` keeps `meter_entity`. `ha_dsmr` subscribes to the DSMR integration over the HA WebSocket; `mqtt_p1` reads a topic; `ha_signed` subscribes to one signed entity over the HA WebSocket |
|
||||
| `meter_phases` | 1 | 1 or 3. Must match the telegram, or every telegram is rejected and logged |
|
||||
| `meter_max_age_s` | 30 | Beyond this the reading is stale: grid power reads as *missing*, and the existing failsafe commands 0 W |
|
||||
| `meter_max_age_s` | 30 | Beyond this the reading is stale and grid power reads as *missing*. On its own it does **not** command 0 W — see the timing note below. It is also the longest a reading is held forward into the 15-minute average |
|
||||
| `meter_mqtt_topic` | | `mqtt_p1` only |
|
||||
| `p1_import_entity` | | The **unsigned** consumption sensor. Do not point this at a signed template |
|
||||
| `p1_export_entity` | | The **unsigned** injection sensor |
|
||||
| `p1_phase_import_entities` | `[]` | L1..L3, in order. Needed for the capacity-tariff peak on a three-phase connection |
|
||||
| `p1_phase_export_entities` | `[]` | L1..L3, in order |
|
||||
| `p1_net_entity` | | `ha_signed` only. The **signed** net-power sensor: `+` import, `-` export |
|
||||
| `p1_phase_net_entities` | `[]` | `ha_signed` only. L1..L3, in order, each signed the same way. Needed for the capacity-tariff peak on a three-phase connection. **The list length must equal `meter_phases`** |
|
||||
|
||||
Both per-phase lists are checked against `meter_phases` **once at startup**: a
|
||||
list of the wrong length disables P1 ingestion with an error in the log, rather
|
||||
than letting every telegram fail its phase-count check one at a time. Leaving
|
||||
the list empty is fine and is not an error — you simply get no per-phase
|
||||
figures, and therefore no capacity-tariff peak. On a three-phase connection
|
||||
that is a much bigger omission than it looks: on a surveyed reading here the
|
||||
phases carried 2769 W of import while the connection netted 187 W, so the
|
||||
billed quantity is understated roughly fifteenfold if the phases are missing.
|
||||
|
||||
#### How long a dead meter takes to reach 0 W
|
||||
|
||||
`meter_max_age_s` and `stale_input_s` **stack**. They are two different clocks
|
||||
and neither one is the whole answer:
|
||||
|
||||
| step | option | default |
|
||||
|---|---|---|
|
||||
| telegrams stop, P1 sample goes stale, grid power starts reading *missing* | `meter_max_age_s` | 30 s |
|
||||
| inputs have been missing long enough for the loop to command 0 W | `stale_input_s` | 15 s |
|
||||
| **total, meter death → 0 W commanded by this add-on** | | **45 s** |
|
||||
|
||||
So in P1 mode `stale_input_s` is *not* "how long inputs may be missing before
|
||||
commanding 0 W" measured from the meter dying — it is measured from the moment
|
||||
the P1 sample already went stale. Size the pair together: the ESP32's own
|
||||
watchdog commands 0 W after ~30 s of silence from this add-on regardless, and
|
||||
that layer is unaffected by either option.
|
||||
|
||||
There is **no fallback to an inverter-side power figure**, deliberately. The
|
||||
inverter's own AC power tracks its battery almost perfectly and the real meter
|
||||
@@ -102,6 +156,42 @@ emits nothing, which is indistinguishable — to anything watching the value —
|
||||
a meter that has died. Watching the age instead separates the two: it climbs when
|
||||
telegrams stop and resets when they arrive, whatever the reading says.
|
||||
|
||||
The entity is only created when `meter_source` is not `off`. With P1 ingestion
|
||||
disabled there is nothing feeding it, and an age sensor climbing with no ingester
|
||||
behind it would trip the firmware watchdog on a system that is working fine.
|
||||
|
||||
> **Known limit, `mqtt_p1`.** The age measures *arrival*. On the MQTT path a
|
||||
> bridge that is stuck republishing its last telegram keeps arriving, so the age
|
||||
> stays near zero and a frozen meter still looks fresh. Detecting *that* needs a
|
||||
> change-detector rather than an arrival-detector, and it is not in this version.
|
||||
|
||||
> ⚠️ **Known limit, `ha_signed` — do not drive a watchdog off this age yet.**
|
||||
> On the HA WebSocket paths the age is stamped when a `state_changed` arrives,
|
||||
> which means it measures *time since the value last changed*, not time since
|
||||
> the meter last reported. Home Assistant offers nothing better: a repeated
|
||||
> reading produces no `state_changed`, does **not** advance `last_reported` on
|
||||
> either the REST or the WebSocket serialiser, and `state_reported` cannot be
|
||||
> subscribed to over the WebSocket at all (`Event filter is required for event
|
||||
> state_reported`). All three measured on the ENV-01 rig against the real
|
||||
> HomeWizard integration with the meter frozen: 0 `state_changed` in 70 s and no
|
||||
> timestamp movement anywhere.
|
||||
>
|
||||
> `ha_dsmr` mostly escapes this because a DSMR telegram updates several entities
|
||||
> and something in the set almost always moves. **`ha_signed` has exactly one
|
||||
> entity, so a healthy meter under a flat load is indistinguishable from a dead
|
||||
> one.** This is not hypothetical: in our own captures
|
||||
> (`sim/scenarios/ha-p1_meter_active_power-2026-08-20.json`) the real house meter
|
||||
> went **42.2 s and 97.0 s** between changes, and 23 Aug peaks at 29.1 s — all
|
||||
> past the default `meter_max_age_s` of 30.
|
||||
>
|
||||
> So `sensor.p1_sample_age_s` on `ha_signed` is safe to *read*, and it is
|
||||
> correct whenever the value is moving, but it must not yet be thresholded by
|
||||
> the ESP32 stale-input watchdog: a quiet house would trip the battery to 0 W.
|
||||
> Raising `meter_max_age_s` is **not** the fix — the two conditions produce an
|
||||
> identical signal, so a bigger number only chooses which of the two errors you
|
||||
> get. The real fix is an arrival stamp the meter itself provides, i.e. reading
|
||||
> the HomeWizard local API directly rather than through an HA entity.
|
||||
|
||||
### Control
|
||||
|
||||
| option | default | meaning |
|
||||
@@ -113,12 +203,35 @@ telegrams stop and resets when they arrive, whatever the reading says.
|
||||
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
|
||||
| `step_w` | 10 | Quantisation |
|
||||
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. **Do not set to 1** |
|
||||
| `integrator_max_w` | 3000 | Bound on the loop's accumulator, separate from `max_w`. Caps how much stale error can be waiting to unwind when the sign flips. **Keep it above `max_w`, and do not set it equal to `max_w`** |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one *changed* meter reading, not a fixed period - see the note below. **Do not set to 1** |
|
||||
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
|
||||
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
|
||||
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W |
|
||||
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W. In P1 mode this clock starts only *after* `meter_max_age_s` has already expired — the two stack, see "How long a dead meter takes to reach 0 W" |
|
||||
| `auto_start` | false | Start controlling on boot (only after commissioning) |
|
||||
|
||||
#### Saturation is counted in cycles, not seconds
|
||||
|
||||
The specification states the saturation window as **"> 10 s"**. This add-on counts
|
||||
**cycles** instead, and that is a deliberate, accepted deviation rather than an
|
||||
oversight - the acceptance criterion is not met as literally written.
|
||||
|
||||
A cycle here is one *changed* meter reading: the controller only runs the loop when the
|
||||
meter value differs from the previous poll. At the reference P1's ~5 s update rate the
|
||||
default of 3 cycles is usually around 15 s, but there is **no guaranteed wall-clock
|
||||
window** - a meter that repeats the same value stalls the counter for as long as it
|
||||
repeats.
|
||||
|
||||
Two reasons that is acceptable:
|
||||
|
||||
- the control law is a pure function with no clock, which is what makes it testable
|
||||
without hardware, and a seconds-based window would have to live in the controller;
|
||||
- a stalled counter is a detection-latency limit and not a runaway risk. The condition
|
||||
that stalls it - an unchanging meter - stops the whole loop, so nothing accumulates
|
||||
while it is stalled.
|
||||
|
||||
If a guaranteed window matters on your site, raise `saturation_cycles` for a fast meter,
|
||||
and treat the figure as "N meter updates" rather than "N seconds".
|
||||
|
||||
#### Why `target_grid_w` is not zero
|
||||
|
||||
The deadband is a one-way ratchet: any resting point inside it holds until
|
||||
|
||||
@@ -28,16 +28,22 @@ class Tuning:
|
||||
step_w: int = 10
|
||||
saturation_w: float = 500.0
|
||||
saturation_cycles: int = 3
|
||||
# ⚠️ The integrator's OWN bound, and deliberately not max_w. A commercial
|
||||
# controller on this same site clamped only its output and still reported
|
||||
# 14 768 W: with the inverter switched off its integrator climbed ~130 W
|
||||
# every 4 s past 10 kW while the output sat on the 5 kW rail, so the moment
|
||||
# the error flipped there were minutes of accumulated wind to burn off
|
||||
# before the command moved at all. Bounding the accumulator is what makes
|
||||
# recovery time finite; bounding the output only hides it.
|
||||
# Headroom above max_w is wanted (a legitimate large error must not be
|
||||
# truncated at the rail), headroom without limit is the bug.
|
||||
integrator_max_w: float = 3000.0
|
||||
# The integrator's own bound. None means "follow max_w", which is the
|
||||
# default and the recommended setting.
|
||||
#
|
||||
# ⚠️ DO NOT RAISE THIS ABOVE max_w without a measurement to justify it.
|
||||
# Every watt of integrator above the rail is a watt of wind that has to be
|
||||
# burned off before the command can start moving the other way, i.e. extra
|
||||
# cycles of discharge into an already-exporting meter after every
|
||||
# saturation event. Measured on the closed-loop sim, 4000 W load dropped to
|
||||
# 0: at integrator_max_w == max_w the command is 1000 W two cycles later; at
|
||||
# 1.5x max_w it is 1800 W. The output clamp already bounds what reaches the
|
||||
# wire, so headroom here buys nothing but unwind latency.
|
||||
#
|
||||
# It is a separate key because it has to be able to be SMALLER than max_w,
|
||||
# which is the only direction that buys anything: it caps unwind latency
|
||||
# below what the rail implies. Merging it into max_w would take that away.
|
||||
integrator_max_w: float | None = None
|
||||
# What the meter should rest at, in W. Negative = a slight export.
|
||||
# ⚠️ The deadband is a one-way ratchet: any resting point inside it holds
|
||||
# forever, and the meter's IMPORT register counts every positive one with
|
||||
@@ -54,9 +60,9 @@ class Decision:
|
||||
sat_count: int
|
||||
frozen: bool
|
||||
reason: str
|
||||
# The integrator AFTER this cycle, pre-clamp-to-max_w. Carry it back in as
|
||||
# `i_w` next cycle; that is what keeps it a separate quantity from the
|
||||
# command, which is the whole point of the bound above.
|
||||
# The integrator AFTER this cycle, before the output clamp, the slew limit
|
||||
# and quantisation. Carry it back in as `i_w` next cycle; that is what keeps
|
||||
# it a separate quantity from the command.
|
||||
i_w: float = 0.0
|
||||
|
||||
|
||||
@@ -89,14 +95,19 @@ def compute(
|
||||
# lets slew be larger than saturation_w.
|
||||
#
|
||||
# The spec states this window twice and differently: "> 10 s" (§11.2) and
|
||||
# "3 samples" (§10.3). Cycles are authoritative here because this function
|
||||
# has no clock - it is driven one cycle per meter update by run_control(),
|
||||
# which only calls cycle() when the meter value changes. At the ~5 s
|
||||
# HomeWizard P1 cadence the default 3 cycles is ~15 s, i.e. the stricter
|
||||
# reading of the two. On a faster meter it is not, so saturation_cycles is
|
||||
# configurable and must be raised to keep the window over 10 s.
|
||||
# ponytail: a seconds-based window would mean plumbing wall-clock or dt
|
||||
# into a pure function whose whole value is that it has neither.
|
||||
# "3 samples" (§10.3). This counts CYCLES, and a cycle is not a unit of
|
||||
# time: run_control() calls cycle() only when the meter value CHANGES
|
||||
# (`if self.grid != last_grid`), so three cycles is three distinct meter
|
||||
# readings and nothing more. At the reference P1's ~5 s update rate that is
|
||||
# usually ~15 s, but there is no upper bound on it - a meter that repeats a
|
||||
# value stalls the counter.
|
||||
#
|
||||
# That is a detection-latency limit, not a windup hazard: the same
|
||||
# condition that stalls the counter stalls the whole loop, so nothing
|
||||
# accumulates in the meantime either. If a wall-clock window is ever
|
||||
# required, it belongs in Controller (which has a clock) and not here.
|
||||
# ponytail: this function is worth keeping clockless; the ceiling is that
|
||||
# saturation_cycles cannot express a guaranteed number of seconds.
|
||||
saturated_now = abs(prev_w - actual_w) > tuning.saturation_w
|
||||
sat_count = min(sat_count + 1, 10) if saturated_now else 0
|
||||
frozen = sat_count >= tuning.saturation_cycles
|
||||
@@ -112,32 +123,78 @@ def compute(
|
||||
|
||||
# --- the integrator ----------------------------------------------------
|
||||
# This loop is in velocity form: the accumulator IS the commanded power, so
|
||||
# for years "the integrator" and "the output" were one variable and could
|
||||
# not be bounded apart. `i_w` is that accumulator made explicit. A caller
|
||||
# that passes nothing gets the old behaviour exactly - seeded from the last
|
||||
# command every cycle - and main.py carries it instead, which is what turns
|
||||
# the two clamps below into two independent limits.
|
||||
# "the integrator" and "the output" were one variable and could not be
|
||||
# bounded apart. `i_w` is that accumulator made explicit; main.py carries it
|
||||
# between cycles, which is what turns the two clamps into two limits.
|
||||
#
|
||||
# Passing i_w=None re-seeds it from the last command every cycle. With
|
||||
# integrator_max_w following max_w that reduces this function to the exact
|
||||
# velocity form it replaced, frozen branch included - asserted by an
|
||||
# exhaustive comparison against a transcription of the old law in
|
||||
# test_control.py, not by inspection. Break either the gate or the bound
|
||||
# below and that test is what tells you the equivalence went with it.
|
||||
if i_w is None:
|
||||
i_w = float(prev_w)
|
||||
limit = tuning.max_w if tuning.integrator_max_w is None else tuning.integrator_max_w
|
||||
|
||||
if abs(error) < tuning.deadband_w:
|
||||
reason = "deadband"
|
||||
else:
|
||||
step_i = tuning.gain * error
|
||||
# ⚠️ Freeze means "may not wind FURTHER", not "may not move". A strict
|
||||
# freeze would strand the command at whatever it had reached until the
|
||||
# inverter started tracking again - and the inverter is not tracking,
|
||||
# that is what saturation means, so nothing would ever release it. The
|
||||
# unwind direction is the escape route and stays open; the same rule is
|
||||
# applied again to the output below.
|
||||
if not frozen or abs(i_w + step_i) < abs(i_w):
|
||||
i_w = i_w + step_i
|
||||
moved = i_w + tuning.gain * error
|
||||
# ⚠️ Freeze means "may not wind FURTHER in the direction it is already
|
||||
# pushing". It may fall, cross zero, or reverse outright.
|
||||
#
|
||||
# It must NOT be encoded as "only corrections that shrink |i_w|": that
|
||||
# is unsatisfiable for BOTH signs of error whenever the correction is
|
||||
# larger than twice the integrator, i.e. every time the integrator is
|
||||
# near zero. The loop then sits at its last value forever, because what
|
||||
# clears the freeze is the inverter tracking again and not-tracking is
|
||||
# the definition of saturation. Measured on that encoding: 0 W held
|
||||
# indefinitely into a 2 kW import, where this form recovers next cycle.
|
||||
#
|
||||
# This is the same asymmetric rule the output freeze uses below, which
|
||||
# has been in service on real hardware. It is applied here as well
|
||||
# because the requirement is that the INTEGRATOR stop accumulating, not
|
||||
# only the command.
|
||||
#
|
||||
# ⚠️ EXACTLY ZERO IS ITS OWN CASE, and it must be handled explicitly
|
||||
# rather than falling into one of the two branches. "May not wind
|
||||
# further in the direction it is already pushing" has no referent at
|
||||
# zero: nothing is wound, and neither direction is "further". Writing
|
||||
# this as `if i_w > 0 ... else ...` silently files zero under
|
||||
# rising-only and permanently blocks the first push toward charging -
|
||||
# the same deadlock as the shrink-only encoding above, mirrored in sign,
|
||||
# and reachable because main.py resets i_w to exactly 0.0 on every stop
|
||||
# and every reseed. Measured before the fix: 12 800 of 25 920 frozen
|
||||
# ticks at i_w == 0.0 held the integrator, 8 304 of them changing the
|
||||
# emitted command, worst case abandoning a 2 kW charge into a 4 kW
|
||||
# export.
|
||||
#
|
||||
# Freezing at zero would also be pointless: the freeze exists to stop
|
||||
# accumulation running away, and a first step from zero is bounded by
|
||||
# the gain, the output clamp and the slew limit like any other.
|
||||
if not frozen or i_w == 0.0:
|
||||
i_w = moved
|
||||
elif i_w > 0:
|
||||
i_w = min(moved, i_w)
|
||||
else:
|
||||
i_w = max(moved, i_w)
|
||||
|
||||
# ⚠️ Applied EVERY cycle, frozen or not, and before the output clamp: the
|
||||
# freeze is conditional, this bound is not. Order matters only in that the
|
||||
# command below is derived from the already-bounded integrator, so no
|
||||
# accumulated value can reach the wire even once.
|
||||
i_w = max(-tuning.integrator_max_w, min(tuning.integrator_max_w, i_w))
|
||||
# ⚠️ Applied EVERY cycle, frozen or not: the freeze is conditional, this
|
||||
# bound is not. It is what makes the worst-case unwind time finite and
|
||||
# knowable instead of a function of how long the error happened to stand.
|
||||
bounded = max(-limit, min(limit, i_w))
|
||||
if bounded != i_w:
|
||||
# ⚠️ SAFETY-03 (alarm whenever the loop winds into a rail) must watch
|
||||
# for THIS, not for "clamped" below. At the default limit == max_w the
|
||||
# integrator bound is reached first and the command derived from it can
|
||||
# then never exceed max_w, so "clamped" is unreachable on a default
|
||||
# install - it survives only for a configuration that deliberately lets
|
||||
# the integrator run above the rail. Two reasons rather than one
|
||||
# because the two events want different alarms: "i-clamped" is the loop
|
||||
# winding, "clamped" is a command that came out over the rating anyway.
|
||||
reason = "i-clamped"
|
||||
i_w = bounded
|
||||
want = i_w
|
||||
|
||||
# ⚠️ Maintenance shaping (charge-only, cheap-window floor) used to live
|
||||
|
||||
@@ -39,7 +39,7 @@ from .control import Tuning, compute, maintenance_charge_floor, peak_at_risk
|
||||
from .hass import HomeAssistant
|
||||
from .maintenance import IDLE, MaintConfig, Maintenance
|
||||
from .mqtt import MqttPublisher
|
||||
from .p1 import P1Ingest, build_source
|
||||
from .p1 import P1Ingest, build_source, is_enabled
|
||||
from . import web
|
||||
|
||||
OPTIONS_PATH = "/data/options.json"
|
||||
@@ -71,7 +71,11 @@ class Controller:
|
||||
step_w=int(opts.get("step_w", 10)),
|
||||
saturation_w=float(opts.get("saturation_w", 500)),
|
||||
saturation_cycles=int(opts.get("saturation_cycles", 3)),
|
||||
integrator_max_w=float(opts.get("integrator_max_w", 3000)),
|
||||
# 0 / unset means "follow max_w", which is the recommended
|
||||
# value. Read the note in control.py before raising it above
|
||||
# max_w: every watt above the rail is unwind latency.
|
||||
integrator_max_w=(float(opts["integrator_max_w"])
|
||||
if opts.get("integrator_max_w") else None),
|
||||
)
|
||||
self.maint = Maintenance(
|
||||
MaintConfig(
|
||||
@@ -92,7 +96,7 @@ class Controller:
|
||||
# until it opts in.
|
||||
self.p1 = P1Ingest(phases=int(opts.get("meter_phases", 1)),
|
||||
max_age_s=float(opts.get("meter_max_age_s", 30)))
|
||||
self.p1_enabled = str(opts.get("meter_source", "off")) not in ("off", "")
|
||||
self.p1_enabled = is_enabled(opts)
|
||||
|
||||
# live state
|
||||
self.auto = bool(store.data.get("auto", opts.get("auto_start", False)))
|
||||
@@ -320,16 +324,26 @@ class Controller:
|
||||
await asyncio.sleep(1)
|
||||
|
||||
def publish(self) -> None:
|
||||
self.mqtt.publish({
|
||||
values = {
|
||||
"setpoint": self.target,
|
||||
"grid": self.grid,
|
||||
"battery": self.batt,
|
||||
"soc": self.soc,
|
||||
"phase": self.maint.phase,
|
||||
"status": "running" if self.auto else "stopped",
|
||||
}
|
||||
# ⚠️ ONLY when P1 ingestion is actually running. The ESP32's stale-input
|
||||
# watchdog subscribes to sensor.p1_sample_age_s and forces the layer-1
|
||||
# failsafe once it reaches max_age_s. With meter_source off there is no
|
||||
# ingester feeding it, so published_age_s would be time-since-startup
|
||||
# climbing without bound - i.e. every existing install would cross the
|
||||
# threshold within 30 s and pin its inverter at 0 W forever. Publishing
|
||||
# nothing leaves the entity non-existent, which is the status quo and
|
||||
# what has_state() in the firmware is checking for.
|
||||
if self.p1_enabled:
|
||||
# Recomputed here, once a second, on purpose - see P1Ingest.
|
||||
"p1_age": round(self.p1.published_age_s, 1),
|
||||
})
|
||||
values["p1_age"] = round(self.p1.published_age_s, 1)
|
||||
self.mqtt.publish(values)
|
||||
|
||||
async def shutdown(self) -> None:
|
||||
"""Deterministic wind-down. Do not skip this."""
|
||||
@@ -497,6 +511,7 @@ async def amain() -> None:
|
||||
broker.get("port", 1883) if broker else 1883,
|
||||
broker.get("username") if broker else None,
|
||||
broker.get("password") if broker else None,
|
||||
omit=() if is_enabled(opts) else ("p1_age",),
|
||||
)
|
||||
except Exception as err: # noqa: BLE001
|
||||
_LOG.warning("MQTT unavailable (%s) - continuing without status entities", err)
|
||||
|
||||
@@ -60,7 +60,12 @@ AVAILABILITY = f"{BASE}/availability"
|
||||
|
||||
|
||||
class MqttPublisher:
|
||||
def __init__(self, host, port, username=None, password=None):
|
||||
def __init__(self, host, port, username=None, password=None, omit=()):
|
||||
# `omit` drops sensor keys from discovery entirely. ⚠️ Announcing a
|
||||
# sensor that nothing will ever publish to is not harmless here:
|
||||
# p1_sample_age_s is a watchdog input, and an entity that exists but is
|
||||
# never fed is a worse signal than one that does not exist at all.
|
||||
self.omit = set(omit)
|
||||
self.enabled = mqtt is not None and bool(host)
|
||||
self.client = None
|
||||
if not self.enabled:
|
||||
@@ -94,6 +99,8 @@ class MqttPublisher:
|
||||
|
||||
def _announce(self) -> None:
|
||||
for key, object_id, name, unit, dev_class, state_class, icon in SENSORS:
|
||||
if key in self.omit:
|
||||
continue
|
||||
cfg = {
|
||||
"name": name,
|
||||
"object_id": object_id,
|
||||
|
||||
+203
-15
@@ -4,13 +4,22 @@ Everything downstream trusts this module: the safety checks, the capacity-tariff
|
||||
peak, the optimizer, the control loop's sign. So three things happen here and
|
||||
nowhere else.
|
||||
|
||||
1. The IMPORT/EXPORT DERIVATION. A Belgian P1 meter exposes two UNSIGNED
|
||||
registers - consumption and injection - never one signed figure. Net power
|
||||
is `import_w - export_w`, positive = import, and that subtraction is done
|
||||
1. The IMPORT/EXPORT DERIVATION. A Belgian P1 read over DSMR exposes two
|
||||
UNSIGNED registers - consumption and injection. Net power is
|
||||
`import_w - export_w`, positive = import, and that subtraction is done
|
||||
exactly once, here (spec §5.2: "the derivation is the EMS's job, not a
|
||||
template the user has to write"). A second copy of it somewhere else is a
|
||||
second chance to invert the control loop.
|
||||
|
||||
Some P1 readers - the HomeWizard P1 among them - publish the OTHER shape:
|
||||
one SIGNED figure, positive = import, and no unsigned registers at all.
|
||||
`split_signed()` fans that back out into the same two magnitudes, so there
|
||||
is still exactly one internal representation and one sign convention. ⚠️ It
|
||||
lives here, next to the subtraction, for the same reason the subtraction
|
||||
does: the moment a user is asked to write two template sensors that split a
|
||||
signed value, the sign convention is back in unreviewed YAML underneath a
|
||||
safety input, which is precisely what §5.2 moved into the EMS.
|
||||
|
||||
2. THE INGEST TIMESTAMP. Every accepted sample is stamped on arrival. A value
|
||||
with no age is a value that cannot be trusted (§5.2), and staleness is the
|
||||
failsafe trigger (§11.2).
|
||||
@@ -47,6 +56,7 @@ _LOG = logging.getLogger("goodwe.p1")
|
||||
|
||||
SOURCE_HA = "ha_dsmr"
|
||||
SOURCE_MQTT = "mqtt_p1"
|
||||
SOURCE_HA_SIGNED = "ha_signed"
|
||||
|
||||
QUARTER_S = 900
|
||||
|
||||
@@ -78,7 +88,7 @@ class P1Sample:
|
||||
ingest_ts: datetime # tz-aware UTC, set at ingest
|
||||
ingest_mono: float # time.monotonic() at ingest - see age_s()
|
||||
telegram_ts: datetime | None # from the telegram, where the source has one
|
||||
source: str # SOURCE_HA | SOURCE_MQTT
|
||||
source: str # SOURCE_HA | SOURCE_MQTT | SOURCE_HA_SIGNED
|
||||
import_w: float # unsigned magnitude, as the meter reports it
|
||||
export_w: float # unsigned magnitude
|
||||
net_w: float # import_w - export_w (+ import, - export)
|
||||
@@ -129,6 +139,29 @@ def _watts(value, what: str) -> float:
|
||||
return out
|
||||
|
||||
|
||||
def split_signed(net_w) -> tuple[float, float]:
|
||||
"""One signed figure -> the (import, export) magnitudes the module speaks.
|
||||
|
||||
The inverse of make_sample's subtraction, and the easy direction: no second
|
||||
register to disagree with, so there is nothing to mix a fresh reading with a
|
||||
stale one. `+` is import, `-` is export - verified in test_p1.py against real
|
||||
captured readings from this house's own meter, not against a datasheet.
|
||||
|
||||
⚠️ Exactly one of the two comes out non-zero. Splitting into `(max(v,0),
|
||||
max(-v,0))` rather than clamping keeps `import_w - export_w == v` exactly, so
|
||||
the signed value the meter published survives the round trip bit for bit -
|
||||
a control loop must not be steered by a number that changed on the way in.
|
||||
|
||||
⚠️ Validation is `_watts`, the same gate the unsigned path uses: NaN,
|
||||
infinity, non-numbers and the §20 open-question-5 unsigned-decode
|
||||
contamination (64954 for -582 W) are all refused here rather than believed.
|
||||
A signed source makes that check MORE important, not less - on this path
|
||||
64954 is not obviously wrong the way a negative "unsigned" register is.
|
||||
"""
|
||||
v = _watts(net_w, "net")
|
||||
return (v, 0.0) if v >= 0 else (0.0, -v)
|
||||
|
||||
|
||||
def make_sample(source: str, import_w, export_w, *, phases: int,
|
||||
phase_import_w=None, phase_export_w=None,
|
||||
telegram_ts: datetime | None = None,
|
||||
@@ -213,8 +246,16 @@ class QuarterAverager:
|
||||
halves credited to the two blocks, never attributed wholly to either.
|
||||
"""
|
||||
|
||||
def __init__(self, phases: int = 1):
|
||||
def __init__(self, phases: int = 1, max_hold_s: float = 30.0):
|
||||
self.phases = phases
|
||||
# ⚠️ How long one sample may be held forward before the series is
|
||||
# treated as a gap rather than a plateau. Without this the meter can die
|
||||
# while importing 5 kW, come back ten minutes later, and the hold-forward
|
||||
# credits 5 kW x 600 s to the capacity-tariff accumulator - a fabricated
|
||||
# peak, on a permanent record, from data that was never measured. Set
|
||||
# from meter_max_age_s: the point past which the reading is not trusted
|
||||
# for control is the point past which it must not be billed either.
|
||||
self.max_hold_s = float(max_hold_s)
|
||||
self._block: int | None = None # epoch seconds of the block start
|
||||
self._acc = 0.0 # W*s of offtake in the open block
|
||||
self._pp_acc = [0.0] * phases
|
||||
@@ -273,16 +314,22 @@ class QuarterAverager:
|
||||
return closed
|
||||
|
||||
cursor = self._last_t
|
||||
# Beyond this instant the held value stops being evidence of anything.
|
||||
# The stretch from here to `t` is walked so the block boundaries are
|
||||
# still crossed correctly, but nothing is accumulated and `_elapsed`
|
||||
# does not grow - which is what makes a closed block, always divided by
|
||||
# the full 900 s, actually get dragged down by the missing coverage.
|
||||
hold_end = self._last_t + self.max_hold_s
|
||||
while True:
|
||||
end = self._block + QUARTER_S
|
||||
stop = min(t, end)
|
||||
dt = stop - cursor
|
||||
if dt > 0:
|
||||
self._acc += max(self._last_net, 0.0) * dt
|
||||
covered = max(0.0, min(stop, hold_end) - cursor)
|
||||
if covered > 0:
|
||||
self._acc += max(self._last_net, 0.0) * covered
|
||||
if self._last_pp is not None:
|
||||
for i, v in enumerate(self._last_pp[: self.phases]):
|
||||
self._pp_acc[i] += max(v, 0.0) * dt
|
||||
self._elapsed += dt
|
||||
self._pp_acc[i] += max(v, 0.0) * covered
|
||||
self._elapsed += covered
|
||||
cursor = stop
|
||||
if stop < end:
|
||||
break
|
||||
@@ -321,7 +368,9 @@ class P1Ingest:
|
||||
def __init__(self, phases: int = 1, max_age_s: float = 30.0):
|
||||
self.phases = phases
|
||||
self.max_age_s = float(max_age_s)
|
||||
self.averager = QuarterAverager(phases)
|
||||
# The same threshold governs control and billing: a reading too old to
|
||||
# steer by is too old to bill by. See QuarterAverager.max_hold_s.
|
||||
self.averager = QuarterAverager(phases, max_hold_s=self.max_age_s)
|
||||
self.blocks: list[QuarterBlock] = []
|
||||
self.samples = 0
|
||||
self.parse_errors = 0
|
||||
@@ -477,9 +526,17 @@ class HaDsmrSource:
|
||||
continue
|
||||
payload = json.loads(msg.data)
|
||||
if payload.get("id") == 2 and payload.get("type") == "result":
|
||||
# ⚠️ Prime the cache, but do NOT build a sample from it.
|
||||
# get_states returns whatever HA currently holds, which
|
||||
# after a Core restart is a RestoreEntity value of unknown
|
||||
# age. Stamping that with ingest_ts=now resets the age to
|
||||
# zero and reports a fresh meter that may have been dead for
|
||||
# an hour - a synthetic sample hiding the outage from the
|
||||
# watchdog that exists to catch it. The cache is what lets
|
||||
# the FIRST real state_changed build a complete sample; the
|
||||
# age stays honest until one arrives.
|
||||
for obj in payload.get("result") or []:
|
||||
self._absorb(obj.get("entity_id"), obj.get("state"))
|
||||
self._schedule()
|
||||
elif payload.get("type") == "event":
|
||||
data = (payload.get("event") or {}).get("data") or {}
|
||||
if data.get("entity_id") not in self.ids:
|
||||
@@ -644,9 +701,118 @@ class MqttP1Source:
|
||||
self.ingest.reject(err)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# transport 3: Home Assistant WebSocket, one signed entity
|
||||
# --------------------------------------------------------------------------- #
|
||||
class HaSignedSource(HaDsmrSource):
|
||||
"""The same websocket, subscribed to ONE signed power entity.
|
||||
|
||||
For readers that publish net power as a single signed figure - a HomeWizard
|
||||
P1's `sensor.p1_meter_active_power`, positive = import - rather than the two
|
||||
unsigned DSMR registers. This is the meter actually installed at the house,
|
||||
and `ha_dsmr` cannot read it: it needs two registers and refuses a negative
|
||||
one outright, which is every exporting telegram.
|
||||
|
||||
⚠️ A subclass, not a copy. The connect / auth / subscribe / reconnect /
|
||||
`_absorb` machinery above is transport, not shape, and it has already been
|
||||
debugged once - notably "prime the cache from get_states but never build a
|
||||
sample out of it" and "a reconnect emits nothing". Only `_wanted` (which
|
||||
entity ids) and `build` (how they become a sample) differ, so only those two
|
||||
are overridden. Everything TEL-01 established therefore applies unchanged:
|
||||
ingest timestamping, meter_max_age_s, the clock-recomputed age sensor, and
|
||||
`unavailable` treated as a missing reading rather than 0 W.
|
||||
|
||||
⚠️ THE AGE ON THIS TRANSPORT MEASURES TIME SINCE THE VALUE CHANGED, not time
|
||||
since the meter reported, and on one entity those are very different things.
|
||||
Home Assistant offers no arrival signal for a repeated reading: it emits no
|
||||
`state_changed`, it does not advance `last_reported` on either serialiser,
|
||||
and `state_reported` cannot be subscribed to over the websocket at all
|
||||
("Event filter is required for event state_reported"). All three measured on
|
||||
the ENV-01 rig against the real HomeWizard integration with the meter frozen
|
||||
- 0 state_changed in 70 s, no timestamp movement anywhere.
|
||||
|
||||
`ha_dsmr` mostly escapes it because a DSMR telegram moves several entities at
|
||||
once. This transport has ONE, so a healthy meter under a flat load looks
|
||||
exactly like a dead one - and our own capture has the real meter going 42.2 s
|
||||
and 97.0 s between changes, both past the default max_age_s of 30. Hence
|
||||
DOCS.md: sensor.p1_sample_age_s is correct while the value moves and must not
|
||||
yet be thresholded by the firmware watchdog on this transport. Raising
|
||||
meter_max_age_s does not fix it, it only chooses which of the two errors you
|
||||
get. The fix is an arrival stamp from the meter itself - reading the
|
||||
HomeWizard local API rather than an HA entity - which is a separate ticket.
|
||||
|
||||
⚠️ The debounce is inherited but does nothing useful here, and that is fine:
|
||||
one telegram is one entity, so there is no burst of per-entity events to
|
||||
coalesce and no window in which a new reading sits beside a stale one. It
|
||||
costs one scheduled sleep per telegram at ~0.2 Hz. Left in place rather than
|
||||
special-cased, because a second code path through build() is a second place
|
||||
for the sign to go wrong.
|
||||
"""
|
||||
|
||||
def _wanted(self) -> set[str]:
|
||||
out = set()
|
||||
if self.entities.get("net"):
|
||||
out.add(self.entities["net"])
|
||||
out.update(e for e in self.entities.get("phase_net") or [] if e)
|
||||
return out
|
||||
|
||||
def build(self) -> bool:
|
||||
"""Assemble one sample from the cache. Returns True if one was accepted."""
|
||||
net_id = self.entities.get("net")
|
||||
if net_id not in self.cache:
|
||||
return False
|
||||
pn = [self.cache.get(e) for e in self.entities.get("phase_net") or []]
|
||||
if pn and None in pn:
|
||||
return False # incomplete phase set: wait, do not guess
|
||||
try:
|
||||
imp, exp = split_signed(self.cache[net_id])
|
||||
pi = pe = None
|
||||
if pn:
|
||||
# ponytail: this split is arithmetically redundant today -
|
||||
# make_sample subtracts the two lists again and does not
|
||||
# sign-check per-phase figures, so handing it the signed values
|
||||
# with a zero export list produces the identical tuple. Verified:
|
||||
# mutating it that way leaves all 174 checks green, i.e. no test
|
||||
# can tell the difference, and it is recorded here rather than
|
||||
# left as a silent equivalent mutant for the next reviewer to
|
||||
# rediscover. Kept because `phase_import_w` means a MAGNITUDE:
|
||||
# a negative in it is the double-signing that make_sample refuses
|
||||
# outright for the connection-level registers, and the day that
|
||||
# check is extended per-phase the shortcut breaks the meter, not
|
||||
# the test.
|
||||
pairs = [split_signed(v) for v in pn]
|
||||
pi = [a for a, _ in pairs]
|
||||
pe = [b for _, b in pairs]
|
||||
self.ingest.submit(make_sample(
|
||||
SOURCE_HA_SIGNED, imp, exp,
|
||||
phases=self.ingest.phases,
|
||||
phase_import_w=pi, phase_export_w=pe,
|
||||
# ⚠️ No telegram_ts, for the same reason as ha_dsmr: HA's
|
||||
# last_changed is when the VALUE changed, which on a steady meter
|
||||
# is minutes ago while the telegram is current. sensor.
|
||||
# p1_sample_age_s is what covers a genuinely frozen meter.
|
||||
))
|
||||
return True
|
||||
except P1Error as err:
|
||||
self.ingest.reject(err)
|
||||
return False
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# selection
|
||||
# --------------------------------------------------------------------------- #
|
||||
def is_enabled(opts: dict) -> bool:
|
||||
"""Whether P1 ingestion is switched on at all.
|
||||
|
||||
⚠️ One definition, because three places depend on it and they MUST agree:
|
||||
where the grid reading comes from, whether the ingest task is started, and
|
||||
whether sensor.p1_sample_age_s is announced over MQTT discovery. An age
|
||||
sensor announced with no ingester behind it is a watchdog input nobody is
|
||||
feeding, and the ESP32 trips on it.
|
||||
"""
|
||||
return str(opts.get("meter_source", "off") or "off").strip() not in ("off", "")
|
||||
|
||||
|
||||
def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
|
||||
"""Return the transport named by `meter_source`, or None if disabled.
|
||||
|
||||
@@ -654,7 +820,7 @@ def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
|
||||
changing transport is a config edit, never a code path.
|
||||
"""
|
||||
source = str(opts.get("meter_source", "off") or "off").strip()
|
||||
if source in ("off", ""):
|
||||
if not is_enabled(opts):
|
||||
return None
|
||||
if source == SOURCE_HA:
|
||||
return HaDsmrSource(session, ingest, {
|
||||
@@ -663,12 +829,34 @@ def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
|
||||
"phase_import": opts.get("p1_phase_import_entities") or [],
|
||||
"phase_export": opts.get("p1_phase_export_entities") or [],
|
||||
})
|
||||
if source == SOURCE_HA_SIGNED:
|
||||
net = str(opts.get("p1_net_entity", "") or "").strip()
|
||||
phase_net = [str(e).strip() for e in
|
||||
(opts.get("p1_phase_net_entities") or []) if str(e).strip()]
|
||||
# ⚠️ Both of these are checked ONCE here rather than per telegram. A
|
||||
# misconfigured source otherwise fails silently in the only way that
|
||||
# looks exactly like a healthy one that has not been sent anything yet:
|
||||
# no samples, a climbing age, and the firmware watchdog holding the
|
||||
# battery at 0 W with nothing in the log saying why.
|
||||
if not net:
|
||||
_LOG.error("meter_source %s needs p1_net_entity - P1 ingestion "
|
||||
"disabled (sensor.p1_sample_age_s would otherwise be "
|
||||
"announced with nothing feeding it)", SOURCE_HA_SIGNED)
|
||||
return None
|
||||
if phase_net and len(phase_net) != ingest.phases:
|
||||
_LOG.error("p1_phase_net_entities has %d entities but meter_phases "
|
||||
"is %d - P1 ingestion disabled. Every telegram would be "
|
||||
"rejected on the phase-count check.",
|
||||
len(phase_net), ingest.phases)
|
||||
return None
|
||||
return HaSignedSource(session, ingest,
|
||||
{"net": net, "phase_net": phase_net})
|
||||
if source == SOURCE_MQTT:
|
||||
broker = broker or {}
|
||||
return MqttP1Source(ingest, str(opts.get("meter_mqtt_topic", "")),
|
||||
broker.get("host"), broker.get("port", 1883),
|
||||
broker.get("username"), broker.get("password"))
|
||||
if source:
|
||||
_LOG.error("meter_source %r is not %s or %s - P1 ingestion disabled",
|
||||
source, SOURCE_HA, SOURCE_MQTT)
|
||||
_LOG.error("meter_source %r is not one of %s - P1 ingestion disabled",
|
||||
source, ", ".join((SOURCE_HA, SOURCE_MQTT, SOURCE_HA_SIGNED)))
|
||||
return None
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.2.1"
|
||||
version: "0.3.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
@@ -42,7 +42,9 @@ options:
|
||||
# --- P1 meter ingestion (specs §5.2 / §14 `meter:`) -------------------------
|
||||
# `off` keeps the original single meter_entity path above, so an existing
|
||||
# install is untouched until it opts in. ha_dsmr subscribes to the DSMR
|
||||
# integration's entities over the HA WebSocket; mqtt_p1 reads the topic below.
|
||||
# integration's entities over the HA WebSocket; mqtt_p1 reads the topic below;
|
||||
# ha_signed reads ONE signed HA entity (+ import / - export), which is what a
|
||||
# HomeWizard P1 publishes and what ha_dsmr cannot consume.
|
||||
meter_source: "off"
|
||||
meter_phases: 1
|
||||
meter_max_age_s: 30
|
||||
@@ -55,6 +57,15 @@ options:
|
||||
# three-phase connection; the list length must equal meter_phases.
|
||||
p1_phase_import_entities: []
|
||||
p1_phase_export_entities: []
|
||||
# ha_signed only. ONE signed net-power sensor: positive = import from the
|
||||
# grid, negative = export to it. Do NOT split it into two template sensors -
|
||||
# the split is done in the add-on (p1.split_signed) precisely so the sign
|
||||
# convention is tested rather than living in unreviewed YAML.
|
||||
p1_net_entity: ""
|
||||
# Optional, in L1..L3 order, each one signed the same way. Same role as
|
||||
# p1_phase_import_entities: the capacity-tariff peak on a three-phase
|
||||
# connection. The list length must equal meter_phases.
|
||||
p1_phase_net_entities: []
|
||||
|
||||
# --- control ---------------------------------------------------------------
|
||||
max_w: 2000
|
||||
@@ -65,7 +76,7 @@ options:
|
||||
step_w: 10
|
||||
saturation_w: 500
|
||||
saturation_cycles: 3
|
||||
integrator_max_w: 3000
|
||||
integrator_max_w: 0
|
||||
heartbeat_s: 10
|
||||
stale_input_s: 15
|
||||
auto_start: false
|
||||
@@ -98,7 +109,7 @@ schema:
|
||||
batt_invert: bool
|
||||
setpoint_entity: str
|
||||
|
||||
meter_source: list(off|ha_dsmr|mqtt_p1)
|
||||
meter_source: list(off|ha_dsmr|mqtt_p1|ha_signed)
|
||||
# ⚠️ 2 is accepted by this range but is not a real Belgian connection. A
|
||||
# telegram whose phase count disagrees is rejected at ingest and logged, so a
|
||||
# mis-set 2 shows up immediately as "0 telegrams accepted" rather than as a
|
||||
@@ -112,6 +123,9 @@ schema:
|
||||
- str
|
||||
p1_phase_export_entities:
|
||||
- str
|
||||
p1_net_entity: str?
|
||||
p1_phase_net_entities:
|
||||
- str
|
||||
|
||||
max_w: int(100,5000)
|
||||
gain: float(0.05,1.0)
|
||||
@@ -121,7 +135,7 @@ schema:
|
||||
step_w: int(1,100)
|
||||
saturation_w: int(100,2000)
|
||||
saturation_cycles: int(1,10)
|
||||
integrator_max_w: int(100,15000)
|
||||
integrator_max_w: int(0,15000)
|
||||
heartbeat_s: int(2,25)
|
||||
stale_input_s: int(5,120)
|
||||
auto_start: bool
|
||||
|
||||
@@ -24,6 +24,63 @@ def check(name, cond):
|
||||
fails.append(name)
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# COVERAGE AUDIT - measured, not executed. Read this before adding a mechanism.
|
||||
#
|
||||
# THE INVARIANT: every mechanism in compute() must be noticed by AT LEAST TWO
|
||||
# checks when it is deleted. If you add a mechanism to compute(), re-run the
|
||||
# audit and add it to the table. If a figure here drops, a check has started
|
||||
# passing for a reason other than the one it names.
|
||||
#
|
||||
# THE TECHNIQUE, because there is no script to run: replace one mechanism in
|
||||
# control.py with a no-op, run this file, count the failures, restore. That is
|
||||
# the converse of the usual mutation - not "does a wrong value fail?" but "does
|
||||
# anyone notice when the mechanism is GONE?". It is kept as a comment rather
|
||||
# than as tooling on purpose: the only cheap way to automate it is to key on
|
||||
# source lines, which goes stale silently, and a green audit that has quietly
|
||||
# stopped testing anything is precisely the failure this ticket exists to fix.
|
||||
# A comment cannot go stale-green, because it never claims to be running.
|
||||
#
|
||||
# Measured at 389d9ec. Numbers are the lead's independent reproduction.
|
||||
#
|
||||
# mechanism in compute() checks that fail when deleted
|
||||
# ------------------------------------------ -----------------------------
|
||||
# integrator freeze (AC 3) 2
|
||||
# integrator clamp (AC 1) 6
|
||||
# integrator bound follows max_w 4
|
||||
# output clamp 3
|
||||
# slew limit 4
|
||||
# output freeze 2
|
||||
# deadband 5
|
||||
# quantisation 2
|
||||
# saturation detector, `saturated_now = False` 11
|
||||
# saturation duration (AC 2), fires instantly 2
|
||||
# sat counter reset on a good cycle 6
|
||||
# target_grid_w bias 3
|
||||
# i_w=None seeding from prev_w 6
|
||||
#
|
||||
# The detector figure is for the `saturated_now = False` form specifically;
|
||||
# disabling it further down as `frozen = False` is a weaker mutation and gives
|
||||
# 10. Reproduce the same form or the number will not match.
|
||||
#
|
||||
# ⚠️ IT HAS FOUND A DEAD MECHANISM TWICE, BOTH THE SAME WAY: a clamp standing in
|
||||
# for the mechanism under test. Deleting the integrator freeze once failed
|
||||
# NOTHING, because the fixtures sat at max_w 2000 and the integrator bound
|
||||
# truncated a wound value back to exactly 2000 - the assertion passed on the
|
||||
# clamp. The output clamp was masked the same way by the integrator bound.
|
||||
# Hence: A FIXTURE MUST SIT CLEAR OF EVERY RAIL IT IS NOT TESTING. Where a test
|
||||
# names one mechanism, make that mechanism the binding one (see TCLAMP and TF).
|
||||
#
|
||||
# ⚠️ RUN MUTATIONS WITH `python -B` AND CLEAR app/__pycache__. CPython
|
||||
# invalidates a .pyc on (source mtime in whole seconds, source size), so a
|
||||
# same-second rewrite that also preserves the file size reuses stale bytecode
|
||||
# and the suite reports on code you are no longer running. It under-reported one
|
||||
# mutation here as 2 where the true figure is 6. The error is one-directional -
|
||||
# stale bytecode can only under-report - so every figure above is a lower bound
|
||||
# at worst, and the two zeros ever recorded were both confirmed by fixing them
|
||||
# and watching the count rise, which a caching artefact cannot do.
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
print("control law")
|
||||
|
||||
# Deadband: inside meter noise, hold exactly - do not drift.
|
||||
@@ -41,13 +98,22 @@ check("proportional step (gain 0.6)", d.target_w == 300)
|
||||
d = compute(prev_w=0, grid_w=-500, actual_w=0, tuning=T)
|
||||
check("export drives charging", d.target_w == -300)
|
||||
|
||||
# Clamp
|
||||
d = compute(prev_w=1900, grid_w=1000, actual_w=1900, tuning=Tuning(max_w=2000, slew_w=5000))
|
||||
# Clamp.
|
||||
# ⚠️ integrator_max_w is lifted clear of max_w so that the OUTPUT clamp is the
|
||||
# mechanism under test. Left at the default the integrator bound truncates
|
||||
# first, these two assertions pass on that alone, and deleting the output clamp
|
||||
# fails nothing - the same masking that hid the integrator freeze.
|
||||
TCLAMP = Tuning(max_w=2000, slew_w=5000, integrator_max_w=5000)
|
||||
d = compute(prev_w=1900, grid_w=1000, actual_w=1900, tuning=TCLAMP)
|
||||
check("clamped to max_w", d.target_w == 2000)
|
||||
|
||||
# Slew: from 0 with a huge error, no more than slew_w in one cycle.
|
||||
d = compute(prev_w=0, grid_w=5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000))
|
||||
check("slew limits one cycle", d.target_w == 1000)
|
||||
d = compute(prev_w=-1900, grid_w=-1000, actual_w=-1900, tuning=TCLAMP)
|
||||
check("clamped to -max_w", d.target_w == -2000)
|
||||
d = compute(prev_w=0, grid_w=-5000, actual_w=0, tuning=Tuning(max_w=5000, slew_w=1000))
|
||||
check("slew limits one cycle, charging", d.target_w == -1000)
|
||||
|
||||
# Saturation needs DURATION: one diverging cycle must NOT freeze.
|
||||
t = Tuning(saturation_w=500, saturation_cycles=3)
|
||||
@@ -78,7 +144,7 @@ print("SAFETY-04: the integrator is bounded apart from the output")
|
||||
# The historical runaway, with its real numbers. A commercial controller on
|
||||
# this site, with the inverter switched OFF, wound ~130 W every 4 s past 10 kW
|
||||
# and reported 14 768 W while its output clamp sat at 5 kW. At gain 0.6 that
|
||||
# rate is a standing error of 130/0.6 ≈ 217 W that never resolves, because the
|
||||
# rate is a standing error of 130/0.6 = 217 W that never resolves, because the
|
||||
# inverter is not there to resolve it. 150 cycles is past the ~113 it took to
|
||||
# reach 14 768 W at that rate.
|
||||
RUNAWAY_ERROR = 130.0 / 0.6
|
||||
@@ -86,12 +152,12 @@ RUNAWAY_CYCLES = 150
|
||||
HISTORICAL_W = 14768.0
|
||||
|
||||
|
||||
def runaway(tuning):
|
||||
def runaway(tuning, sign=1):
|
||||
"""Inverter off: it reports 0 W forever, the error never clears."""
|
||||
prev, i_w, sat = 0.0, 0.0, 0
|
||||
worst_i, worst_cmd = 0.0, 0.0
|
||||
for _ in range(RUNAWAY_CYCLES):
|
||||
d = compute(prev_w=prev, grid_w=RUNAWAY_ERROR, actual_w=0.0,
|
||||
d = compute(prev_w=prev, grid_w=sign * RUNAWAY_ERROR, actual_w=0.0,
|
||||
tuning=tuning, sat_count=sat, i_w=i_w)
|
||||
prev, i_w, sat = d.target_w, d.i_w, d.sat_count
|
||||
worst_i = max(worst_i, abs(i_w))
|
||||
@@ -99,33 +165,113 @@ def runaway(tuning):
|
||||
return worst_i, worst_cmd
|
||||
|
||||
|
||||
TR = Tuning(max_w=2000, integrator_max_w=3000)
|
||||
TR = Tuning(max_w=2000) # integrator_max_w unset => follows max_w
|
||||
wi, wc = runaway(TR)
|
||||
check(f"runaway: integrator plateaus at {wi:.0f} W (<= 3000)", wi <= TR.integrator_max_w)
|
||||
check(f"runaway: integrator plateaus at {wi:.0f} W (<= 2000)", wi <= TR.max_w)
|
||||
check(f"runaway: emitted command peaks at {wc:.0f} W (<= 2000)", wc <= TR.max_w)
|
||||
check("runaway: nowhere near the historical 14 768 W", wc < HISTORICAL_W / 4)
|
||||
|
||||
# ...and with the saturation detector deliberately defeated, so that only the
|
||||
# clamp is holding. This is the AC that says the two mechanisms are
|
||||
# independent: kill one, the other still bounds it.
|
||||
TD = Tuning(max_w=2000, integrator_max_w=3000, saturation_w=1e9)
|
||||
# clamp is holding. Kill one mechanism, the other still bounds it.
|
||||
TD = Tuning(max_w=2000, saturation_w=1e9)
|
||||
wi, wc = runaway(TD)
|
||||
check(f"runaway with the detector defeated: integrator still <= 3000 ({wi:.0f} W)",
|
||||
wi <= TD.integrator_max_w)
|
||||
check(f"runaway with the detector defeated: integrator still bounded ({wi:.0f} W)",
|
||||
wi <= TD.max_w)
|
||||
check("runaway with the detector defeated: command still <= max_w", wc <= TD.max_w)
|
||||
|
||||
# The bound is not max_w. If someone "simplifies" them into one key this fails.
|
||||
d = compute(prev_w=0, grid_w=6000, actual_w=0,
|
||||
tuning=Tuning(max_w=2000, integrator_max_w=3000, slew_w=5000))
|
||||
check("integrator bound is separate from the output clamp",
|
||||
d.i_w == 3000 and d.target_w == 2000)
|
||||
# The mirror: the same runaway driving the other way. An export that never
|
||||
# clears winds the integrator negative just as hard.
|
||||
wi, wc = runaway(Tuning(max_w=2000), sign=-1)
|
||||
check(f"runaway (export direction): integrator bounded at {wi:.0f} W", wi <= 2000)
|
||||
check("runaway (export direction): emitted command <= max_w", wc <= 2000)
|
||||
|
||||
# Freeze = does not accumulate. Same input twice; the integrator must not move.
|
||||
TF = Tuning(saturation_w=500, saturation_cycles=3)
|
||||
# The bound is a separate quantity, and the useful direction is BELOW max_w:
|
||||
# there it binds first and caps unwind latency tighter than the rail does.
|
||||
d = compute(prev_w=0, grid_w=6000, actual_w=0,
|
||||
tuning=Tuning(max_w=2000, integrator_max_w=1000, slew_w=5000))
|
||||
check("integrator bound binds independently of the output clamp",
|
||||
d.i_w == 1000 and d.target_w == 1000)
|
||||
|
||||
# Freeze = may not wind further in the direction it is already pushing.
|
||||
# ⚠️ max_w is raised WELL above the fixtures on purpose. At the default 2000
|
||||
# the integrator bound truncates a wound value back to exactly 2000 and
|
||||
# satisfies these assertions on its own, so deleting the freeze outright
|
||||
# failed nothing - the clamp was standing in for the mechanism under test.
|
||||
# Any fixture here must sit clear of every rail, or it tests the rail.
|
||||
TF = Tuning(saturation_w=500, saturation_cycles=3, max_w=5000)
|
||||
f1 = compute(prev_w=2000, grid_w=800, actual_w=0, tuning=TF, sat_count=3, i_w=2000.0)
|
||||
check("frozen: integration does not accumulate", f1.i_w == 2000.0 and f1.frozen)
|
||||
check("frozen: integration does not wind further", f1.i_w == 2000.0 and f1.frozen)
|
||||
f2 = compute(prev_w=2000, grid_w=-800, actual_w=0, tuning=TF, sat_count=3, i_w=2000.0)
|
||||
check("frozen: unwinding is still allowed", f2.i_w < 2000.0)
|
||||
# ...and the same two on the charging side. Every freeze rule in this file has
|
||||
# a mirror, because the one that did not is the defect that got through review.
|
||||
f3 = compute(prev_w=-2000, grid_w=-800, actual_w=0, tuning=TF, sat_count=3, i_w=-2000.0)
|
||||
check("frozen (charging): integration does not wind further", f3.i_w == -2000.0)
|
||||
f4 = compute(prev_w=-2000, grid_w=800, actual_w=0, tuning=TF, sat_count=3, i_w=-2000.0)
|
||||
check("frozen (charging): unwinding is still allowed", f4.i_w > -2000.0)
|
||||
|
||||
# ⚠️ REGRESSION, and the reason the first cut of SAFETY-04 was rejected. A
|
||||
# freeze encoded as "only corrections that shrink |i_w|" is unsatisfiable for
|
||||
# BOTH signs of error whenever |correction| > 2*|i_w|, so near zero the loop
|
||||
# stops moving forever - the freeze cannot clear, because clearing it needs the
|
||||
# inverter to track and not-tracking is what saturation means. Measured on that
|
||||
# encoding: 0 W held into a 2 kW import for as long as the sim ran.
|
||||
z = compute(prev_w=0, grid_w=2000, actual_w=600, tuning=T, sat_count=3, i_w=0.0)
|
||||
check("frozen at i_w=0: a 2 kW import still moves the command",
|
||||
z.frozen and z.target_w == 1000)
|
||||
# ...and the next cycle the inverter is inside saturation_w of the command, so
|
||||
# the freeze clears on its own. Deadlock would show up here as frozen=True.
|
||||
z2 = compute(prev_w=1000, grid_w=1000, actual_w=600, tuning=T,
|
||||
sat_count=z.sat_count, i_w=z.i_w)
|
||||
check("frozen at i_w=0: the freeze then clears", not z2.frozen)
|
||||
# Same stranding on the other side: a small positive integrator against export.
|
||||
z3 = compute(prev_w=100, grid_w=-1000, actual_w=800, tuning=T, sat_count=3, i_w=100.0)
|
||||
check("frozen at i_w=+100: a 1 kW export still moves the command",
|
||||
z3.frozen and z3.target_w < 0)
|
||||
z4 = compute(prev_w=-100, grid_w=1000, actual_w=-800, tuning=T, sat_count=3, i_w=-100.0)
|
||||
check("frozen at i_w=-100: a 1 kW import still moves the command",
|
||||
z4.frozen and z4.target_w > 0)
|
||||
|
||||
# ⚠️ EXACTLY ZERO, BOTH DIRECTIONS. This boundary has a history: the first cut
|
||||
# deadlocked here under import, and the fix for it deadlocked here under export
|
||||
# because `if i_w > 0 ... else ...` files 0.0 under rising-only. main.py resets
|
||||
# i_w to exactly 0.0 on every stop and every reseed, so it is a normal state,
|
||||
# not a corner.
|
||||
zi = compute(prev_w=0, grid_w=2000, actual_w=600, tuning=T, sat_count=3, i_w=0.0)
|
||||
check("frozen at i_w=0.0: an import push moves the integrator",
|
||||
zi.frozen and zi.i_w > 0)
|
||||
ze = compute(prev_w=0, grid_w=-2000, actual_w=-600, tuning=T, sat_count=3, i_w=0.0)
|
||||
check("frozen at i_w=0.0: an export push moves the integrator",
|
||||
ze.frozen and ze.i_w < 0)
|
||||
# The COMMAND still holds at 0 W in that second case, and that is release/1.0's
|
||||
# rule, not a leftover: at prev_w == 0 the output freeze forbids starting to
|
||||
# charge while saturated, because commanding 0 while the inverter reports
|
||||
# hundreds of watts means something else is driving the bus. Asserted so that
|
||||
# nobody "fixes" it by accident - the integrator moving is what this ticket
|
||||
# owns, the command rule belongs to the output freeze.
|
||||
check("frozen at i_w=0.0: the output freeze still blocks a charge from 0 W",
|
||||
ze.target_w == 0.0)
|
||||
# Where prev_w is already charging the output freeze does NOT block, and there
|
||||
# the difference reaches the wire: held at 0.0 the integrator abandons the
|
||||
# charge mid-export.
|
||||
zc = compute(prev_w=-2000, grid_w=-4000, actual_w=-600, tuning=T, sat_count=3, i_w=0.0)
|
||||
check("frozen at i_w=0.0: a charge is not abandoned during heavy export",
|
||||
zc.target_w == -2000.0)
|
||||
|
||||
# The general property, rather than another handful of points: while frozen the
|
||||
# integrator may be held ONLY when the correction would push it further from
|
||||
# zero on the side it already sits. Any other hold is a deadlock.
|
||||
stuck = []
|
||||
for i0 in [x * 25.0 for x in range(-80, 81)]:
|
||||
for g in [x * 100.0 for x in range(-40, 41)]:
|
||||
err = g - T.target_grid_w
|
||||
if abs(err) < T.deadband_w:
|
||||
continue
|
||||
dd = compute(prev_w=0.0, grid_w=g, actual_w=1500.0, tuning=T, sat_count=3, i_w=i0)
|
||||
if dd.i_w == i0 and not ((i0 > 0 and err > 0) or (i0 < 0 and err < 0)):
|
||||
stuck.append((i0, g))
|
||||
check(f"frozen integrator never deadlocks, over {161*81} states"
|
||||
+ (f" (e.g. {stuck[0]})" if stuck else ""), not stuck)
|
||||
|
||||
# False-positive guard: a normal 2 kW load step must not trip the detector,
|
||||
# because the plant needs several cycles to catch up on every one of them.
|
||||
@@ -137,6 +283,107 @@ for _ in range(12):
|
||||
froze = froze or d.frozen
|
||||
check("a normal 2 kW load step does not trip the saturation freeze", not froze)
|
||||
|
||||
# The convergence sim below runs WITHOUT a carried integrator. This is the same
|
||||
# 2 kW step in the configuration that actually ships, where main.py carries it.
|
||||
prev, actual, sat, i_w = 0.0, 0.0, 0, 0.0
|
||||
carried = 0
|
||||
for _ in range(12):
|
||||
d = compute(prev, 2000.0 - actual, actual, T, sat, i_w)
|
||||
prev, sat, i_w = d.target_w, d.sat_count, d.i_w
|
||||
actual = actual + 0.94 * (prev - actual)
|
||||
carried += 1
|
||||
if abs(2000.0 - actual) < T.deadband_w:
|
||||
break
|
||||
check(f"carried integrator converges in {carried} cycles (<=6)", carried <= 6)
|
||||
check("carried integrator does not overshoot the load", actual <= 2000.0 + T.deadband_w)
|
||||
|
||||
# ⚠️ REGRESSION: an integrator allowed to wind past the rail buys nothing (the
|
||||
# output clamp already bounds the wire) and costs extra cycles of
|
||||
# wrong-direction power after every saturation event. 4000 W load held to
|
||||
# saturation, then dropped to 0; the figure is the command on the first cycle
|
||||
# after the drop. This is what makes the DOCS advice checkable.
|
||||
def unwind(t):
|
||||
prev, actual, sat, i_w, load = 0.0, 0.0, 0, 0.0, 4000.0
|
||||
for c in range(16):
|
||||
if c == 15:
|
||||
load = 0.0
|
||||
d = compute(prev, load - actual, actual, t, sat, i_w)
|
||||
prev, sat, i_w = d.target_w, d.sat_count, d.i_w
|
||||
actual = actual + 0.94 * (prev - actual)
|
||||
return prev
|
||||
|
||||
|
||||
tight, loose = unwind(Tuning(max_w=2000)), unwind(Tuning(max_w=2000, integrator_max_w=3000))
|
||||
check(f"after saturation ends the command is {tight:.0f} W (<= 1000)", tight <= 1000)
|
||||
check(f"headroom above max_w makes that worse ({loose:.0f} W) - hence the default",
|
||||
loose > tight)
|
||||
|
||||
print("SAFETY-04: the i_w=None path is still release/1.0, exactly")
|
||||
|
||||
|
||||
def legacy(prev, grid, actual, t, sat_count):
|
||||
"""release/1.0's control law, transcribed. Do not 'improve' this."""
|
||||
reason = "tracking"
|
||||
sc = min(sat_count + 1, 10) if abs(prev - actual) > t.saturation_w else 0
|
||||
frozen = sc >= t.saturation_cycles
|
||||
error = grid - t.target_grid_w
|
||||
if abs(error) < t.deadband_w:
|
||||
want, reason = prev, "deadband"
|
||||
else:
|
||||
want = prev + t.gain * error
|
||||
target = max(-t.max_w, min(t.max_w, want))
|
||||
if target != want:
|
||||
reason = "clamped"
|
||||
slewed = max(prev - t.slew_w, min(prev + t.slew_w, target))
|
||||
if slewed != target:
|
||||
reason = "slew-limited"
|
||||
target = slewed
|
||||
if frozen:
|
||||
target = min(target, prev) if prev > 0 else max(target, prev)
|
||||
reason = "saturated-freeze"
|
||||
step = max(1, int(t.step_w))
|
||||
return float(round(target / step) * step), sc, frozen, reason
|
||||
|
||||
|
||||
# ⚠️ Compare EVERYTHING observable, not just the number. A previous version of
|
||||
# this sweep compared (target_w, sat_count) only and passed 3024 cases while
|
||||
# `reason` had silently lost a value - which is the kind of thing a sweep this
|
||||
# broad exists to catch. `frozen` and `reason` are both in the tuple now.
|
||||
#
|
||||
# The one deliberate rename: what release/1.0 called "clamped" is now
|
||||
# "i-clamped", because the truncation happens on the integrator before the
|
||||
# command is derived from it. Aliased here rather than papered over - if any
|
||||
# OTHER reason ever diverges, this check goes red.
|
||||
ALIAS = {"i-clamped": "clamped"}
|
||||
diffs = []
|
||||
seen = set()
|
||||
for tune in (Tuning(), Tuning(target_grid_w=-10.0), Tuning(max_w=5000, slew_w=5000)):
|
||||
for prev in (-2000.0, -500.0, -100.0, 0.0, 100.0, 500.0, 2000.0):
|
||||
for grid in (-6000.0, -1000.0, -500.0, -14.0, 0.0, 14.0, 500.0, 1000.0, 6000.0):
|
||||
for actual in (-2000.0, 0.0, 600.0, 2000.0):
|
||||
for sc in (0, 2, 3, 9):
|
||||
d = compute(prev, grid, actual, tune, sc) # i_w defaults to None
|
||||
seen.add(d.reason)
|
||||
got = (d.target_w, d.sat_count, d.frozen,
|
||||
ALIAS.get(d.reason, d.reason))
|
||||
if got != legacy(prev, grid, actual, tune, sc):
|
||||
diffs.append((prev, grid, actual, sc, got,
|
||||
legacy(prev, grid, actual, tune, sc)))
|
||||
check(f"i_w=None reproduces release/1.0 over {3*7*9*4*4} cases, reason included"
|
||||
+ (f" (first diff {diffs[0]})" if diffs else ""), not diffs)
|
||||
|
||||
# ...and the rename is not a quiet deletion: the signal SAFETY-03 alarms on has
|
||||
# to actually occur in that sweep, or its hook is dead.
|
||||
check("the integrator clamp reports itself as 'i-clamped'", "i-clamped" in seen)
|
||||
|
||||
# "clamped" stays reachable, but only where the integrator is deliberately
|
||||
# allowed above the rail - then BOTH fire and the output clamp, which describes
|
||||
# the value actually emitted, is the one reported.
|
||||
dc = compute(prev_w=0, grid_w=6000, actual_w=0,
|
||||
tuning=Tuning(max_w=2000, integrator_max_w=3000, slew_w=5000))
|
||||
check("the output clamp still reports 'clamped' when it is the binding one",
|
||||
dc.reason == "clamped" and dc.i_w == 3000 and dc.target_w == 2000)
|
||||
|
||||
print("capacity tariff")
|
||||
check("no forecast means no cap", maintenance_charge_floor(2500, None, 3500) == 2500)
|
||||
check("headroom caps the charge", maintenance_charge_floor(2500, 2000, 3500) == 1500)
|
||||
|
||||
@@ -18,8 +18,9 @@ from datetime import datetime, timedelta, timezone
|
||||
import aiohttp # already required by app.p1, so this adds no new dependency
|
||||
|
||||
from app.p1 import (
|
||||
P1Error, P1Ingest, HaDsmrSource, QuarterAverager, SOURCE_HA, SOURCE_MQTT,
|
||||
make_sample, parse_mqtt_payload,
|
||||
P1Error, P1Ingest, HaDsmrSource, HaSignedSource, QuarterAverager,
|
||||
SOURCE_HA, SOURCE_HA_SIGNED, SOURCE_MQTT,
|
||||
build_source, is_enabled, make_sample, parse_mqtt_payload, split_signed,
|
||||
)
|
||||
|
||||
fails = []
|
||||
@@ -56,6 +57,25 @@ def raises(name, fn):
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def built(src):
|
||||
"""`src.build()`, with any escaping exception turned into a visible value.
|
||||
|
||||
⚠️ Legibility of a RED, not leniency. build() is contracted to return a bool
|
||||
and to funnel every bad telegram through ingest.reject() - a guard that goes
|
||||
missing (say the "is the net entity cached at all" one) makes it raise
|
||||
instead. That still fails the suite, but by aborting it with a traceback at
|
||||
whichever check happened to run first, which costs the next person ten
|
||||
minutes deciding whether the suite is broken or the code is. Returning the
|
||||
exception makes it compare unequal to True/False, so the NAMED check goes red
|
||||
and says which rule died.
|
||||
"""
|
||||
try:
|
||||
return src.build()
|
||||
except Exception as err: # noqa: BLE001 - a raise here is itself the failure
|
||||
print(f" build() raised {type(err).__name__}: {err}")
|
||||
return err
|
||||
|
||||
|
||||
def sample(net_import, net_export=0.0, at=BASE, phases=1, pi=None, pe=None):
|
||||
return make_sample(SOURCE_HA, net_import, net_export, phases=phases,
|
||||
phase_import_w=pi, phase_export_w=pe,
|
||||
@@ -229,6 +249,47 @@ before = a.partial_ws
|
||||
a.add(sample(1000.0, at=BASE + timedelta(seconds=5)))
|
||||
check("an out-of-order telegram is dropped, not integrated backwards",
|
||||
a.partial_ws == before and a.elapsed_s == 10.0)
|
||||
# ⚠️ The assertion above is NOT sufficient on its own, and that is the whole
|
||||
# lesson: deleting the guard still passes it, because the negative interval is
|
||||
# separately refused by the `covered > 0` test. What the guard actually prevents
|
||||
# is the REWIND - without it the held timestamp moves back to +5 s and the next
|
||||
# telegram re-integrates the 5..10 s window that was already counted. The damage
|
||||
# only becomes visible one sample later, so the test has to go one sample later.
|
||||
a.add(sample(1000.0, at=BASE + timedelta(seconds=20)))
|
||||
check("...and the held timestamp is not rewound, so the next telegram "
|
||||
"cannot double-count", a.elapsed_s == 20.0 and a.partial_ws == 20000.0)
|
||||
|
||||
# A duplicate telegram (identical timestamp) is the same rule.
|
||||
a = QuarterAverager(1)
|
||||
a.add(sample(1000.0, at=BASE))
|
||||
a.add(sample(1000.0, at=BASE + timedelta(seconds=10)))
|
||||
a.add(sample(4000.0, at=BASE + timedelta(seconds=10)))
|
||||
a.add(sample(1000.0, at=BASE + timedelta(seconds=20)))
|
||||
check("a duplicate timestamp neither re-integrates nor replaces the held value",
|
||||
a.elapsed_s == 20.0 and a.partial_ws == 20000.0)
|
||||
|
||||
# A gap must not be filled with the last held value. The meter dies at 5 kW and
|
||||
# returns ten minutes later; hold-forward would credit 5 kW x 600 s to the
|
||||
# capacity-tariff accumulator - a fabricated peak, on a permanent record, from
|
||||
# data nobody measured.
|
||||
a = QuarterAverager(1, max_hold_s=30.0)
|
||||
a.add(sample(5000.0, at=BASE))
|
||||
a.add(sample(5000.0, at=BASE + timedelta(seconds=600)))
|
||||
check("a 600 s gap is held for at most max_hold_s, not for the whole gap",
|
||||
a.partial_ws == 5000.0 * 30.0)
|
||||
check("the unobserved stretch does not count as elapsed time", a.elapsed_s == 30.0)
|
||||
closed = a.add(sample(5000.0, at=BASE + timedelta(seconds=900)))
|
||||
check("the outage drags the billed quarter down instead of inventing a peak",
|
||||
len(closed) == 1 and abs(closed[0].offtake_avg_w - 300000.0 / 900.0) < 1e-9)
|
||||
check("...nowhere near the 5000 W a hold-forward would have billed",
|
||||
closed[0].offtake_avg_w < 400.0)
|
||||
|
||||
# The cap must not disturb a normally-spaced stream.
|
||||
a = QuarterAverager(1, max_hold_s=30.0)
|
||||
for i in range(0, 121, 5): # a healthy 5 s telegram cadence
|
||||
a.add(sample(2000.0, at=BASE + timedelta(seconds=i)))
|
||||
check("a healthy 5 s cadence is untouched by the hold cap",
|
||||
a.elapsed_s == 120.0 and abs(a.offtake_avg_w - 2000.0) < 1e-9)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ingest timestamp, age and staleness")
|
||||
@@ -482,9 +543,15 @@ async def _e2e():
|
||||
|
||||
live, wire = asyncio.run(_e2e())
|
||||
check("the websocket handshake and subscription complete", live.samples >= 1)
|
||||
# Six state_changed events arrived (two per telegram). The debounce is what
|
||||
# makes that three consistent samples instead of six half-updated ones.
|
||||
check("three telegrams produce three samples, not six", live.samples == 3)
|
||||
# ⚠️ TWO, not three. get_states primes the cache but must NOT build a sample:
|
||||
# HA returns whatever it currently holds, which after a Core restart is a
|
||||
# RestoreEntity value of unknown age, and stamping that with ingest_ts=now
|
||||
# resets the age and reports a fresh meter that may have been dead for an hour.
|
||||
# Only the two real state_changed telegrams become samples. Four state_changed
|
||||
# events arrived (two per telegram); the debounce is what makes those two
|
||||
# consistent samples rather than four half-updated ones.
|
||||
check("connecting does not manufacture a sample from cached HA state",
|
||||
live.samples == 2)
|
||||
check("the final export-dominant telegram nets negative",
|
||||
live.last.net_w == -800.0)
|
||||
check("the sample was built over the wire, tagged with its transport",
|
||||
@@ -492,9 +559,403 @@ check("the sample was built over the wire, tagged with its transport",
|
||||
check("an entity we did not subscribe to is never cached",
|
||||
"sensor.something_else" not in wire.cache and len(wire.cache) == 1)
|
||||
check("a mid-stream unavailable is a parse error, not a sample",
|
||||
live.parse_errors == 1 and live.samples == 3)
|
||||
live.parse_errors == 1 and live.samples == 2)
|
||||
check("the last good reading survives the unavailable", live.net_w == -800.0)
|
||||
check("the averager integrated the live stream", live.averager.elapsed_s > 0.5)
|
||||
check("the averager integrated the live stream", live.averager.elapsed_s > 0.2)
|
||||
|
||||
# The reason get_states still matters: it is what lets the FIRST real telegram
|
||||
# build a complete sample instead of waiting for every entity to change once.
|
||||
check("the primed cache let the first telegram build immediately",
|
||||
live.samples == 2 and live.last.import_w == 0.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed: one signed entity -> the same two magnitudes")
|
||||
# The meter actually fitted at this house is a HomeWizard P1 publishing ONE
|
||||
# signed sensor. ha_dsmr cannot read it - it wants two unsigned registers and
|
||||
# refuses a negative one, which is every exporting telegram.
|
||||
|
||||
check("a positive reading is import", split_signed(1500.0) == (1500.0, 0.0))
|
||||
check("a negative reading is export", split_signed(-900.0) == (0.0, 900.0))
|
||||
check("zero is a balanced reading, not a missing one",
|
||||
split_signed(0.0) == (0.0, 0.0))
|
||||
check("exactly one magnitude is ever non-zero",
|
||||
all(a == 0.0 or b == 0.0 for a, b in
|
||||
(split_signed(v) for v in (-5710.0, -1.0, 0.0, 1.0, 4384.0))))
|
||||
# ⚠️ The split must not change the number. A control loop steered by a value
|
||||
# that was rounded or clamped on the way in is steered by a different meter.
|
||||
check("the split round-trips the signed value exactly",
|
||||
all(make_sample(SOURCE_HA_SIGNED, *split_signed(v), phases=1).net_w == v
|
||||
for v in (-11763.0, -5710.0, -0.5, 0.0, 0.5, 775.0, 4384.0)))
|
||||
|
||||
raises("a non-numeric signed reading is rejected", lambda: split_signed("n/a"))
|
||||
raises("a signed None is rejected, not read as zero", lambda: split_signed(None))
|
||||
raises("a signed NaN is rejected", lambda: split_signed(float("nan")))
|
||||
raises("a signed infinity is rejected", lambda: split_signed(float("inf")))
|
||||
# ⚠️ This one matters MORE on the signed path than on the unsigned one. On
|
||||
# ha_dsmr the §20 contamination is also caught by "unsigned cannot be negative";
|
||||
# here 64954 arrives as a perfectly well-formed positive signed reading and the
|
||||
# plausibility ceiling is the only thing standing in front of it.
|
||||
raises("the 64954 signed-decode contamination is still rejected",
|
||||
lambda: split_signed(64954.0))
|
||||
raises("...and its negative twin too", lambda: split_signed(-64954.0))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed: the sign convention, against real captured readings")
|
||||
# ⚠️ Not a datasheet claim. These are literal values out of
|
||||
# sim/scenarios/ha-p1_meter_active_power-2026-08-{20,23}.json, HA recorder
|
||||
# exports of sensor.p1_meter_active_power at this house, copied here rather than
|
||||
# read from that repo so this file still runs on a laptop with nothing installed
|
||||
# (§17). If the convention were inverted, the physics below would be absurd.
|
||||
|
||||
# 2026-08-23T11:46:52Z - the day's most negative reading, 13:46 local, full sun.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(-5710.0), phases=1)
|
||||
check("the midday PV peak (-5710 W) is EXPORT, not a 5.7 kW draw",
|
||||
s.net_w == -5710.0 and s.export_w == 5710.0 and s.import_w == 0.0)
|
||||
# 2026-08-19T22:00:00Z - midnight local, 20 Aug's file starts here. No sun.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(775.0), phases=1)
|
||||
check("the overnight base load (+775 W) is IMPORT",
|
||||
s.net_w == 775.0 and s.import_w == 775.0 and s.export_w == 0.0)
|
||||
# 2026-08-20T12:20:58Z - 14:20 local, the largest export in either capture.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(-11763.0), phases=1)
|
||||
check("the -11763 W midday extreme is export and survives the ceiling",
|
||||
s.net_w == -11763.0 and s.export_w == 11763.0)
|
||||
# 2026-08-23T10:18:28Z - the largest import in the healthy capture.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(4384.0), phases=1)
|
||||
check("the +4384 W peak is import", s.net_w == 4384.0 and s.import_w == 4384.0)
|
||||
# The whole convention in one line: night draws, midday feeds back.
|
||||
check("night is positive and midday is negative, which is the convention",
|
||||
split_signed(775.0)[0] > 0 and split_signed(-5710.0)[1] > 0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed transport: building a sample out of one entity state")
|
||||
|
||||
NET = {"net": "sensor.p1_meter_active_power", "phase_net": []}
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
sig = HaSignedSource(None, ing, NET, token="x")
|
||||
|
||||
check("nothing cached yet builds nothing", built(sig) is False and ing.last is None)
|
||||
sig._absorb("sensor.p1_meter_active_power", "1000")
|
||||
check("one signed entity is a complete telegram on its own",
|
||||
built(sig) is True and ing.net_w == 1000.0)
|
||||
check("the sample is tagged with its own transport",
|
||||
ing.last.source == SOURCE_HA_SIGNED)
|
||||
sig._absorb("sensor.p1_meter_active_power", "-2500")
|
||||
built(sig)
|
||||
check("a negative state lands as a negative net", ing.net_w == -2500.0)
|
||||
|
||||
before = ing.last
|
||||
sig._absorb("sensor.p1_meter_active_power", "unavailable")
|
||||
check("an unavailable signed entity is a parse error", ing.parse_errors == 1)
|
||||
check("an unavailable entity does not build a sample", built(sig) is False)
|
||||
# ⚠️ The rule the whole ticket turns on: a missing reading is MISSING. Resolving
|
||||
# it to 0 W would read as a perfectly balanced house and defeat the staleness
|
||||
# trigger that FW-01's watchdog is built on.
|
||||
check("an unavailable entity leaves the last good sample untouched, not 0 W",
|
||||
ing.last is before and ing.net_w == -2500.0)
|
||||
sig._absorb("sensor.p1_meter_active_power", "unknown")
|
||||
check("an unknown signed entity is treated the same way", ing.parse_errors == 2)
|
||||
sig._absorb("sensor.p1_meter_active_power", "banana")
|
||||
check("a non-numeric signed state is a parse error, not 0 W",
|
||||
ing.parse_errors == 3 and ing.net_w == -2500.0)
|
||||
sig._absorb("sensor.p1_meter_active_power", "64954")
|
||||
check("64954 is refused at the signed transport too",
|
||||
built(sig) is False and ing.parse_errors == 4)
|
||||
sig._absorb("sensor.not_ours", "123")
|
||||
check("an unsubscribed entity is never cached by the signed transport",
|
||||
"sensor.not_ours" not in sig.cache)
|
||||
|
||||
# A rejected reading must not make the age look fresh - the age is what the
|
||||
# firmware watchdog reads, and a rejection is exactly when it must keep climbing.
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
sig = HaSignedSource(None, ing, dict(NET), token="x")
|
||||
ing.submit(make_sample(SOURCE_HA_SIGNED, 1200, 0, phases=1,
|
||||
ingest_mono=time.monotonic() - 20.0))
|
||||
sig._absorb("sensor.p1_meter_active_power", "unavailable")
|
||||
built(sig)
|
||||
check("a rejected reading does not reset the published age",
|
||||
ing.published_age_s > 19 and ing.net_w == 1200.0)
|
||||
ing.submit(make_sample(SOURCE_HA_SIGNED, 1200, 0, phases=1,
|
||||
ingest_mono=time.monotonic() - 40.0))
|
||||
check("...and the age keeps climbing past max_age_s on its own",
|
||||
ing.stale is True and ing.net_w is None)
|
||||
|
||||
# The three-phase reading the TEL-04 survey recorded at this house: L1 +2301 W,
|
||||
# L2 +468 W, L3 -2582 W, netting +187 W. A signed per-phase set splits the same
|
||||
# way, and the exporting phase must still clamp out of the billed figure.
|
||||
ing3 = P1Ingest(phases=3, max_age_s=30.0)
|
||||
NET3 = {"net": "sensor.p1_meter_active_power",
|
||||
"phase_net": ["sensor.p1_l1", "sensor.p1_l2", "sensor.p1_l3"]}
|
||||
sig3 = HaSignedSource(None, ing3, NET3, token="x")
|
||||
for eid, val in (("sensor.p1_meter_active_power", "187"), ("sensor.p1_l1", "2301")):
|
||||
sig3._absorb(eid, val)
|
||||
check("an incomplete signed phase set waits instead of guessing", built(sig3) is False)
|
||||
sig3._absorb("sensor.p1_l2", "468")
|
||||
sig3._absorb("sensor.p1_l3", "-2582")
|
||||
check("a complete signed three-phase set builds", built(sig3) is True)
|
||||
check("signed per-phase entities keep the exporting phase negative",
|
||||
ing3.last.per_phase_w == (2301.0, 468.0, -2582.0))
|
||||
check("per-phase IMPORT clamps the exporting phase to zero",
|
||||
ing3.last.per_phase_import_w == (2301.0, 468.0, 0.0))
|
||||
check("the phase import sum is 2769 W while the connection nets 187 W",
|
||||
sum(ing3.last.per_phase_import_w) == 2769.0 and ing3.last.net_w == 187.0)
|
||||
check("the signed per-phase tuple length matches meter_phases",
|
||||
len(ing3.last.per_phase_w) == ing3.phases == 3)
|
||||
|
||||
sig_bad = HaSignedSource(None, P1Ingest(phases=3, max_age_s=30.0),
|
||||
{"net": "sensor.net", "phase_net": ["sensor.a", "sensor.b"]},
|
||||
token="x")
|
||||
for eid in ("sensor.net", "sensor.a", "sensor.b"):
|
||||
sig_bad._absorb(eid, "100")
|
||||
check("two phases delivered against meter_phases 3 is rejected, not padded",
|
||||
built(sig_bad) is False and sig_bad.ingest.last is None
|
||||
and sig_bad.ingest.parse_errors == 1)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed transport: end to end against a fake Home Assistant")
|
||||
# The transport is a subclass, so this is what proves the INHERITED machinery -
|
||||
# auth, subscribe, the get_states priming rule, the reconnect-emits-nothing
|
||||
# rule - still behaves when only _wanted() and build() were replaced.
|
||||
|
||||
|
||||
async def _e2e_signed():
|
||||
from aiohttp import web
|
||||
import app.p1 as p1mod
|
||||
|
||||
done = asyncio.Event()
|
||||
eid = "sensor.p1_meter_active_power"
|
||||
|
||||
async def fake_ha(request):
|
||||
ws = web.WebSocketResponse()
|
||||
await ws.prepare(request)
|
||||
await ws.send_json({"type": "auth_required", "ha_version": "2026.8"})
|
||||
auth = await ws.receive_json()
|
||||
assert auth["type"] == "auth" and auth["access_token"] == "tok"
|
||||
await ws.send_json({"type": "auth_ok"})
|
||||
sub = await ws.receive_json()
|
||||
assert sub["type"] == "subscribe_events"
|
||||
await ws.send_json({"id": sub["id"], "type": "result", "success": True})
|
||||
get = await ws.receive_json()
|
||||
assert get["type"] == "get_states"
|
||||
await ws.send_json({"id": get["id"], "type": "result", "success": True, "result": [
|
||||
{"entity_id": eid, "state": "775.0"},
|
||||
{"entity_id": "sensor.something_else", "state": "hello"},
|
||||
]})
|
||||
# Two real telegrams, both literal captured values: overnight import,
|
||||
# then the midday export peak.
|
||||
for val in ("775.0", "-5710.0"):
|
||||
await asyncio.sleep(0.5)
|
||||
await ws.send_json({"type": "event", "event": {"data": {
|
||||
"entity_id": eid,
|
||||
"new_state": {"entity_id": eid, "state": val}}}})
|
||||
await asyncio.sleep(0.5)
|
||||
await ws.send_json({"type": "event", "event": {"data": {
|
||||
"entity_id": eid,
|
||||
"new_state": {"entity_id": eid, "state": "unavailable"}}}})
|
||||
await asyncio.sleep(0.5)
|
||||
done.set()
|
||||
return ws
|
||||
|
||||
srv = web.Application()
|
||||
srv.router.add_get("/ws", fake_ha)
|
||||
runner = web.AppRunner(srv)
|
||||
await runner.setup()
|
||||
site = web.TCPSite(runner, "127.0.0.1", 0)
|
||||
await site.start()
|
||||
port = site._server.sockets[0].getsockname()[1]
|
||||
p1mod.WS_URL = f"http://127.0.0.1:{port}/ws"
|
||||
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
async with aiohttp.ClientSession() as sess:
|
||||
src = HaSignedSource(sess, ing, dict(NET), token="tok")
|
||||
task = asyncio.get_running_loop().create_task(src.run())
|
||||
try:
|
||||
await asyncio.wait_for(done.wait(), 20)
|
||||
await asyncio.sleep(0.5)
|
||||
finally:
|
||||
task.cancel()
|
||||
try:
|
||||
await task
|
||||
except asyncio.CancelledError:
|
||||
pass
|
||||
await runner.cleanup()
|
||||
return ing, src
|
||||
|
||||
|
||||
live, wire = asyncio.run(_e2e_signed())
|
||||
# ⚠️ TWO, not three - the same rule as the ha_dsmr e2e. get_states primes the
|
||||
# cache but must never become a sample: after a Core restart it is a
|
||||
# RestoreEntity value of unknown age, and stamping it with ingest_ts=now reports
|
||||
# a fresh meter that may have been dead for an hour.
|
||||
check("ha_signed does not manufacture a sample from cached HA state",
|
||||
live.samples == 2)
|
||||
check("the signed telegrams arrived over a real websocket",
|
||||
live.last.source == SOURCE_HA_SIGNED)
|
||||
check("the final export telegram nets negative, over the wire",
|
||||
live.last.net_w == -5710.0 and live.last.export_w == 5710.0)
|
||||
check("ha_signed subscribes to the one entity and caches nothing else",
|
||||
wire.ids == {"sensor.p1_meter_active_power"}
|
||||
and "sensor.something_else" not in wire.cache)
|
||||
check("a mid-stream unavailable signed state is a parse error, not a sample",
|
||||
live.parse_errors == 1 and live.samples == 2)
|
||||
# ⚠️ And the cached half is DROPPED, so no later telegram can be assembled out
|
||||
# of a value that stopped reporting.
|
||||
check("an unavailable entity is evicted from the cache", wire.cache == {})
|
||||
check("the last good reading survives the unavailable, and is not 0 W",
|
||||
live.net_w == -5710.0)
|
||||
check("the averager integrated the live signed stream", live.averager.elapsed_s > 0.2)
|
||||
# ⚠️ The entity FW-01 waits on. It must be a number here exactly as it is on the
|
||||
# other transports - the house P1 went 51.1 s and 36.2 s between state changes
|
||||
# overnight, and without this the watchdog false-trips the battery to 0 W.
|
||||
check("sensor.p1_sample_age_s is a live number on this transport too",
|
||||
isinstance(live.published_age_s, float) and live.published_age_s >= 0.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed: selection by config")
|
||||
|
||||
check("ha_signed is enabled", is_enabled({"meter_source": SOURCE_HA_SIGNED}) is True)
|
||||
# ⚠️ `sel`, not `built` - that name is the build() wrapper defined at the top of
|
||||
# this file, and rebinding it here silently disarms every check appended below
|
||||
# this line. Caught in review: an added check went `TypeError: 'HaSignedSource'
|
||||
# object is not callable` and aborted the suite, which is the exact failure the
|
||||
# wrapper exists to prevent, reintroduced by a name collision.
|
||||
sel = build_source({"meter_source": SOURCE_HA_SIGNED,
|
||||
"p1_net_entity": "sensor.p1_meter_active_power"},
|
||||
P1Ingest(), None, None)
|
||||
check("meter_source ha_signed selects the signed transport",
|
||||
isinstance(sel, HaSignedSource))
|
||||
check("...wired to p1_net_entity, and subscribed to exactly that one entity",
|
||||
sel.ids == {"sensor.p1_meter_active_power"})
|
||||
# ⚠️ The three modes must not bleed into each other: ha_dsmr must keep ignoring
|
||||
# p1_net_entity, or a half-configured install silently reads the wrong sensor.
|
||||
plain = build_source({"meter_source": SOURCE_HA,
|
||||
"p1_import_entity": "sensor.i", "p1_export_entity": "sensor.e",
|
||||
"p1_net_entity": "sensor.p1_meter_active_power"},
|
||||
P1Ingest(), None, None)
|
||||
check("ha_dsmr still selects the unsigned transport and ignores p1_net_entity",
|
||||
type(plain) is HaDsmrSource and plain.ids == {"sensor.i", "sensor.e"})
|
||||
check("meter_source off still selects nothing",
|
||||
build_source({"meter_source": "off"}, P1Ingest(), None, None) is None)
|
||||
check("an unrecognised meter_source selects nothing rather than guessing",
|
||||
build_source({"meter_source": "ha_signd"}, P1Ingest(), None, None) is None)
|
||||
|
||||
# ⚠️ Caught once at startup, not once per telegram. A source that is wired up
|
||||
# wrong otherwise fails in the one way indistinguishable from a healthy source
|
||||
# nobody has sent anything to yet: no samples, a climbing age, the watchdog
|
||||
# holding the battery at 0 W, and nothing in the log saying why.
|
||||
check("a blank p1_net_entity is refused rather than silently never receiving",
|
||||
build_source({"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": ""},
|
||||
P1Ingest(), None, None) is None)
|
||||
check("...and whitespace does not sneak past it",
|
||||
build_source({"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": " "},
|
||||
P1Ingest(), None, None) is None)
|
||||
check("a phase list that disagrees with meter_phases is refused at startup",
|
||||
build_source({"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": "sensor.n",
|
||||
"p1_phase_net_entities": ["sensor.a", "sensor.b"]},
|
||||
P1Ingest(phases=3), None, None) is None)
|
||||
check("a phase list that agrees with meter_phases is accepted",
|
||||
isinstance(build_source(
|
||||
{"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": "sensor.n",
|
||||
"p1_phase_net_entities": ["sensor.a", "sensor.b", "sensor.c"]},
|
||||
P1Ingest(phases=3), None, None), HaSignedSource))
|
||||
check("no phase list at all is still fine - per-phase billing is optional",
|
||||
isinstance(build_source(
|
||||
{"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": "sensor.n"},
|
||||
P1Ingest(phases=3), None, None), HaSignedSource))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the age sensor must not exist when P1 is off")
|
||||
# ⚠️ This is a fleet-wide regression guard, not a nicety. The ESP32 watchdog
|
||||
# does `id(p1_age_s).has_state() && id(p1_age_s).state >= max_age_s` and forces
|
||||
# the layer-1 failsafe. published_age_s counts from P1Ingest.__init__, so if the
|
||||
# age were published with meter_source off it would climb past 30 s on every
|
||||
# existing install within half a minute and pin the inverter at 0 W forever.
|
||||
|
||||
from app.mqtt import SENSORS, MqttPublisher # noqa: E402
|
||||
|
||||
check("meter_source off is disabled", is_enabled({"meter_source": "off"}) is False)
|
||||
check("a missing meter_source is disabled", is_enabled({}) is False)
|
||||
check("an empty meter_source is disabled", is_enabled({"meter_source": ""}) is False)
|
||||
check("ha_dsmr is enabled", is_enabled({"meter_source": SOURCE_HA}) is True)
|
||||
check("mqtt_p1 is enabled", is_enabled({"meter_source": SOURCE_MQTT}) is True)
|
||||
|
||||
# The entity id SAFETY-01's firmware subscribes to, pinned by object_id.
|
||||
row = [s for s in SENSORS if s[0] == "p1_age"]
|
||||
check("the age sensor is declared exactly once", len(row) == 1)
|
||||
check("its object_id pins entity_id to sensor.p1_sample_age_s",
|
||||
row[0][1] == "p1_sample_age_s")
|
||||
check("it is published in seconds", row[0][3] == "s")
|
||||
|
||||
|
||||
class _RecordingClient:
|
||||
def __init__(self):
|
||||
self.sent = []
|
||||
|
||||
def publish(self, topic, payload=None, retain=False):
|
||||
# Topic AND payload: object_id, the thing that actually pins the entity
|
||||
# id, only appears in the discovery payload. Recording topics alone made
|
||||
# the "is not announced" check pass for the wrong reason.
|
||||
self.sent.append(f"{topic} {payload}")
|
||||
|
||||
|
||||
def _announced(omit):
|
||||
pub = MqttPublisher(None, 1883, omit=omit) # host None -> never connects
|
||||
pub.client = _RecordingClient()
|
||||
pub._announce()
|
||||
return " ".join(pub.client.sent)
|
||||
|
||||
|
||||
check("with P1 off the age sensor is never announced",
|
||||
"p1_sample_age_s" not in _announced(("p1_age",)))
|
||||
check("the other status entities are still announced with P1 off",
|
||||
"goodwe_grid_power" in _announced(("p1_age",)))
|
||||
check("with P1 on the age sensor IS announced",
|
||||
"p1_sample_age_s" in _announced(()))
|
||||
|
||||
# And the publish dict itself, through the real Controller.
|
||||
from app.main import Controller # noqa: E402
|
||||
|
||||
|
||||
class _Store:
|
||||
data = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
class _Pub:
|
||||
def __init__(self):
|
||||
self.last = {}
|
||||
|
||||
def publish(self, values):
|
||||
self.last = values
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
pub_off = _Pub()
|
||||
Controller({"meter_source": "off"}, None, _Store(), pub_off).publish()
|
||||
check("with P1 off, p1_age is absent from the published payload",
|
||||
"p1_age" not in pub_off.last)
|
||||
check("...while the normal status keys are still published",
|
||||
"setpoint" in pub_off.last and "grid" in pub_off.last)
|
||||
|
||||
pub_on = _Pub()
|
||||
Controller({"meter_source": SOURCE_HA}, None, _Store(), pub_on).publish()
|
||||
check("with P1 on, p1_age is published", "p1_age" in pub_on.last)
|
||||
check("...as a number, so has_state() becomes true only once we feed it",
|
||||
isinstance(pub_on.last["p1_age"], float))
|
||||
|
||||
# ⚠️ And on ha_signed identically - this is the whole reason TEL-04 exists. The
|
||||
# age sensor is a hard prerequisite for the FW-01 flash, and it has to appear on
|
||||
# the transport that can actually read the meter in this house.
|
||||
pub_sig = _Pub()
|
||||
Controller({"meter_source": SOURCE_HA_SIGNED}, None, _Store(), pub_sig).publish()
|
||||
check("with ha_signed selected, p1_age is published too",
|
||||
"p1_age" in pub_sig.last and isinstance(pub_sig.last["p1_age"], float))
|
||||
|
||||